usc security system guidelines...eacs composite cable 'l' schlage pim400-td2 power inner...

49
tel: 949.727.9336 fax: 949.727.7346 web: trcsolutions.com 123 Technology Drive Irvine CA 92618 NOTES, SYMBOLS, CONDUIT & CABLE EY-000 ABBREVIATIONS, SECURITY DESIGNATIONS STC STC

Upload: others

Post on 05-Oct-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: USC SECURITY SYSTEM GUIDELINES...eacs composite cable 'l' schlage pim400-td2 power inner cable 'gy' connection detail color code: bk gr gy rd wh = black = green = gray = red = white

tel: 949.727.9336

fax: 949.727.7346

web: trcsolutions.com

123 Technology Drive

Irvine CA 92618

NOTES, SYMBOLS,

CONDUIT & CABLE

EY-000

ABBREVIATIONS,

SECURITY

DESIGNATIONS

STC

STC

Page 2: USC SECURITY SYSTEM GUIDELINES...eacs composite cable 'l' schlage pim400-td2 power inner cable 'gy' connection detail color code: bk gr gy rd wh = black = green = gray = red = white

EACS COMPOSITE CABLE 'L' DETAIL

USC SECURITY SYSTEM GUIDELINES 123 Technology Drive

Irvine CA 92618

tel 949.727.0373

fax 949.727.7346

EACS COMPOSITE CABLE

JACKET COLOR: WHITE

NOMINAL OD: 0.405''

[NON-SHIELDED]

22AWG - 4 CONDUCTOR

WIRE COLOR: RD / BK / WH / GR

[RD / BK = SPARE]

22AWG - 4 CONDUCTOR

WIRE COLOR: RD / BK / WH / GR

[WH / GR = SPARE]

22AWG - 6 CONDUCTOR

WIRE COLOR: RD / WH / BK / GR / BN / BL

[BL = SPARE]

18AWG - 4 CONDUCTOR

WIRE COLOR: RD / BK / WH / GR

[WH / GR = SPARE]

'CARD READER' INNER CABLE

JACKET COLOR: ORANGE

[SHIELDED]

'DOOR CONTACT' INNER CABLE

JACKET COLOR: WHITE

[NON-SHIELDED]

BL

GY

WH

OR

WH

COLOR CODE:

BL

BK

BR

GR

GY

OR

RD

WH

= BLUE

= BLACK

= BROWN

= GREEN

= GRAY

= ORANGE

= RED

= WHITE

'LOCK POWER' INNER CABLE

JACKET COLOR: GRAY

[NON-SHIELDED]

'REQUEST-TO-EXIT' INNER CABLE

JACKET COLOR: BLUE

[NON-SHIELDED]

Page 3: USC SECURITY SYSTEM GUIDELINES...eacs composite cable 'l' schlage pim400-td2 power inner cable 'gy' connection detail color code: bk gr gy rd wh = black = green = gray = red = white

USC SECURITY SYSTEM GUIDELINES 123 Technology Drive

Irvine CA 92618

tel 949.727.0373

fax 949.727.7346

YL

OR

GR

2-PIN

LOCK POWER

CONNECTOR

(+)

(-)

POWER

MODULE

'PM200'

YL

OR

GR

RD

BK

YL

OR

GR

LOCK

SOLENOID

RD

BK

[SPARE]

GRWH

GY

18AWG - 4 CONDUCTOR

[NON-SHIELDED]

JACKET COLOR: GRAY

[SPARE]

GR WH

COMMAND ACCESS

MODEL PS5 LOCK

POWER SUPPLY

BK RD

COMMAND ACCESS

MODEL VLP-UL-KIT

ELECTRIC LATCH KIT

ELECTRIFIED EXIT HARDWARE

(LATCH ROD TYPE)

VON DUPRIN 33/35 &

VON DUPRIN 98/99 SERIES COLOR CODE:

BK

GR

GY

OR

RD

WH

YL

= BLACK

= GREEN

= GRAY

= ORANGE

= RED

= WHITE

= YELLOW

EACS COMPOSITE CABLE 'L' ELECTRIC LOCK KIT

INNER CABLE 'GY' CONNECTION DETAIL

COMPOSITE CABLE 'L'

INNER CABLE

PULL WIRE SEPARATELY THRU

ELECTRONIC POWER TRANSFER

HINGE(S) FOR REX SWITCH.

GENERAL NOTE:

Page 4: USC SECURITY SYSTEM GUIDELINES...eacs composite cable 'l' schlage pim400-td2 power inner cable 'gy' connection detail color code: bk gr gy rd wh = black = green = gray = red = white

EACS COMPOSITE CABLE 'L' - INNER CABLE 'GY'

ELECTRIFIED PANIC HARDWARE LOCK CONNECTION DETAIL

USC SECURITY SYSTEM GUIDELINES 123 Technology Drive

Irvine CA 92618

tel 949.727.0373

fax 949.727.7346

COLOR CODE:

BK

GR

GY

RD

WH

= BLACK

= GREEN

= GRAY

= RED

= WHITE

[SPARE]

GRWH

GY

18AWG - 4 CONDUCTOR

[NON-SHIELDED]

JACKET COLOR: GRAY

RD

BK

[SPARE]

GR WH

BK RD

2-PIN

LOCK POWER

CONNECTOR

(+)

(-)

ELECTRIFIED EXIT HARDWARE

(NON-LATCH ROD / RIM TYPE)

VON DUPRIN 33/35 &

VON DUPRIN 98/99 SERIES

LOCK

SOLENOID

COMPOSITE CABLE 'L'

INNER CABLE

ALTRONIX LOCK

POWER SUPPLY

(CLASS II)

PULL WIRE SEPARATELY THRU

ELECTRONIC POWER TRANSFER

HINGE(S) FOR REX SWITCH.

GENERAL NOTE:

Page 5: USC SECURITY SYSTEM GUIDELINES...eacs composite cable 'l' schlage pim400-td2 power inner cable 'gy' connection detail color code: bk gr gy rd wh = black = green = gray = red = white

EACS COMPOSITE CABLE 'L' - INNER CABLE 'GY'

ELECTRIFIED MORTISE LOCK CONNECTION DETAIL

USC SECURITY SYSTEM GUIDELINES 123 Technology Drive

Irvine CA 92618

tel 949.727.0373

fax 949.727.7346

COLOR CODE:

BK

GR

GY

RD

WH

= BLACK

= GREEN

= GRAY

= RED

= WHITE

[SPARE]

GRWH

GY

18AWG - 4 CONDUCTOR

[NON-SHIELDED]

JACKET COLOR: GRAY

RD

BK

[SPARE]

GR WH

BK RD

2-PIN

LOCK POWER

CONNECTOR

(+)

(-)

ELECTRIFIED MORTISE LOCK

CORBIN RUSSWIN:

ML2257-LWA-CT6-M30

COMMAND ACCESS:

ML053UxCRU2i

LOCK

SOLENOID

COMPOSITE CABLE 'L'

INNER CABLE

ALTRONIX LOCK

POWER SUPPLY

(CLASS II)

Page 6: USC SECURITY SYSTEM GUIDELINES...eacs composite cable 'l' schlage pim400-td2 power inner cable 'gy' connection detail color code: bk gr gy rd wh = black = green = gray = red = white

EACS COMPOSITE CABLE 'L' - INNER CABLE 'BL'

REQUEST-TO-EXIT (REX) CONNECTION DETAIL

USC SECURITY SYSTEM GUIDELINES 123 Technology Drive

Irvine CA 92618

tel 949.727.0373

fax 949.727.7346

COLOR CODE:

BL

BK

GR

RD

WH

= BLUE

= BLACK

= GREEN

= RED

= WHITE

22AWG - 4 CONDUCTOR

[NON-SHIELDED]

JACKET COLOR: BLUE

[SPARE]

BKRD

WH

GR

INTEGRAL

REX SWITCH

BL

[SPARE]

BK RD

TO EACS

CONTROLLER

GR WH

COMPOSITE CABLE 'L'

INNER CABLE

PULL WIRE SEPARATELY THRU

ELECTRONIC POWER TRANSFER

HINGE(S) FOR REX SWITCH.

GENERAL NOTE:

Page 7: USC SECURITY SYSTEM GUIDELINES...eacs composite cable 'l' schlage pim400-td2 power inner cable 'gy' connection detail color code: bk gr gy rd wh = black = green = gray = red = white

EACS COMPOSITE CABLE 'L' - INNER CABLE 'WH'

DOOR CONTACT CONNECTION DETAIL

USC SECURITY SYSTEM GUIDELINES 123 Technology Drive

Irvine CA 92618

tel 949.727.0373

fax 949.727.7346

COLOR CODE:

BL

BK

GR

RD

WH

= BLUE

= BLACK

= GREEN

= RED

= WHITE

22AWG - 4 CONDUCTOR

[NON-SHIELDED]

JACKET COLOR: WHITE

[SPARE]

GRWH

DOOR CONTACT

SWITCH

WH

[SPARE]

GR WH

TO EACS

CONTROLLER

BL RD

RD

BL

COMPOSITE CABLE 'L'

INNER CABLE

Page 8: USC SECURITY SYSTEM GUIDELINES...eacs composite cable 'l' schlage pim400-td2 power inner cable 'gy' connection detail color code: bk gr gy rd wh = black = green = gray = red = white

EACS COMPOSITE CABLE 'L' - INNER CABLE 'OR'

BIO / CARD READER CONNECTION DETAIL

USC SECURITY SYSTEM GUIDELINES 123 Technology Drive

Irvine CA 92618

tel 949.727.0373

fax 949.727.7346

COLOR CODE:

BL

BK

BN

GR

OR

RD

WH

= BLUE

= BLACK

= BROWN

= GREEN

= ORANGE

= RED

= WHITE

22AWG - 6 CONDUCTOR

[SHIELDED]

JACKET COLOR: ORANGE

BL

[SPARE]

RD

BIO / CARD READER:

AptiQ MODEL MT11

AptiQ MODEL MT15

AptiQ MODEL MTK15

AptiQ MODEL MTMS15

BIOSCRYPT MODEL 4G

OR

WH

BK

GR

BN

BL

[SPARE]

RD

WH

BK

GR

BN

TO EACS

CONTROLLER

COMPOSITE CABLE 'L'

INNER CABLE

Page 9: USC SECURITY SYSTEM GUIDELINES...eacs composite cable 'l' schlage pim400-td2 power inner cable 'gy' connection detail color code: bk gr gy rd wh = black = green = gray = red = white

USC SECURITY SYSTEM GUIDELINES 123 Technology Drive

Irvine CA 92618

tel 949.727.0373

fax 949.727.7346

RD

BK

[SPARE]

GRWH

GY

18AWG - 4 CONDUCTOR

[NON-SHIELDED]

JACKET COLOR: GRAY

[SPARE]

GR WH

ACCESS CONTROL

POWER SUPPLY

(12/24VDC - 250mA)

BK RD

COMPOSITE CABLE 'L'

INNER CABLE

EACS COMPOSITE CABLE 'L' SCHLAGE PIM400-TD2

POWER INNER CABLE 'GY' CONNECTION DETAIL

COLOR CODE:

BK

GR

GY

RD

WH

= BLACK

= GREEN

= GRAY

= RED

= WHITE

Page 10: USC SECURITY SYSTEM GUIDELINES...eacs composite cable 'l' schlage pim400-td2 power inner cable 'gy' connection detail color code: bk gr gy rd wh = black = green = gray = red = white

USC SECURITY SYSTEM GUIDELINES 123 Technology Drive

Irvine CA 92618

tel 949.727.0373

fax 949.727.7346

22AWG - 6 CONDUCTOR

[SHIELDED]

JACKET COLOR: ORANGE

BL

[SPARE]

OR

BL

[SPARE]

RD

BN

WH

GR

BK

TO LENEL LNL-1320

TERMINALS TB8 - D1 / DO / GND

& TB10 - C / NO

COMPOSITE CABLE 'L'

INNER CABLE

EACS COMPOSITE CABLE 'L' SCHLAGE PIM400-TD2

READER INNER CABLE 'OR' CONNECTION DETAIL

COLOR CODE:

BK

BL

BN

GR

OR

RD

WH

= BLACK

= BLUE

= BROWN

= GREEN

= ORANGE

= RED

= WHITE

Page 11: USC SECURITY SYSTEM GUIDELINES...eacs composite cable 'l' schlage pim400-td2 power inner cable 'gy' connection detail color code: bk gr gy rd wh = black = green = gray = red = white

22AWG - 4 CONDUCTOR

[NON-SHIELDED]

JACKET COLOR: WHITE

[SPARE]

GRWH

WH

[SPARE]

GR WH

TO LENEL LNL-1320

TERMINAL TB1 - IN1 / IN1

BL RD

COMPOSITE CABLE 'L'

INNER CABLE

USC SECURITY SYSTEM GUIDELINES 123 Technology Drive

Irvine CA 92618

tel 949.727.0373

fax 949.727.7346

EACS COMPOSITE CABLE 'L' SCHLAGE PIM400-TD2

STATUS INNER CABLE 'WH' CONNECTION DETAIL

COLOR CODE:

BL

GR

RD

WH

= BLUE

= GREEN

= RED

= WHITE

AUXILLARY

INPUT No.1

AUXILLARY

INPUT No.2

Page 12: USC SECURITY SYSTEM GUIDELINES...eacs composite cable 'l' schlage pim400-td2 power inner cable 'gy' connection detail color code: bk gr gy rd wh = black = green = gray = red = white

22AWG - 4 CONDUCTOR

[NON-SHIELDED]

JACKET COLOR: BLUE

[SPARE]

BKRD

BL

[SPARE]

BK RD

TO LENEL LNL-1320

TERMINAL TB1 - IN2 / IN2

GR WH

COMPOSITE CABLE 'L'

INNER CABLE

USC SECURITY SYSTEM GUIDELINES 123 Technology Drive

Irvine CA 92618

tel 949.727.0373

fax 949.727.7346

COLOR CODE:

BK

BL

GR

RD

WH

= BLACK

= BLUE

= GREEN

= RED

= WHITE

EACS COMPOSITE CABLE 'L' SCHLAGE PIM400-TD2

REX INNER CABLE 'BL' CONNECTION DETAIL

AUXILLARY

INPUT No.1

AUXILLARY

INPUT No.2

Page 13: USC SECURITY SYSTEM GUIDELINES...eacs composite cable 'l' schlage pim400-td2 power inner cable 'gy' connection detail color code: bk gr gy rd wh = black = green = gray = red = white

USC SECURITY SYSTEM GUIDELINES 123 Technology Drive

Irvine CA 92618

tel 949.727.0373

fax 949.727.7346

22AWG - 6 CONDUCTOR

[SHIELDED]

JACKET COLOR: ORANGE

BL

[SPARE]

OR

BL

[SPARE]

COMPOSITE CABLE 'L'

INNER CABLE

EACS COMPOSITE CABLE 'L' LENEL LNL-1320

READER INNER CABLE 'OR' CONNECTION DETAIL

COLOR CODE:

BK

BL

BN

GR

OR

RD

WH

= BLACK

= BLUE

= BROWN

= GREEN

= ORANGE

= RED

= WHITE

RD

BN

WH

GR

BK

Page 14: USC SECURITY SYSTEM GUIDELINES...eacs composite cable 'l' schlage pim400-td2 power inner cable 'gy' connection detail color code: bk gr gy rd wh = black = green = gray = red = white

22AWG - 4 CONDUCTOR

[NON-SHIELDED]

JACKET COLOR: WHITE

[SPARE]

GRWH

WH

[SPARE]

GR WH

BL RD

COMPOSITE CABLE 'L'

INNER CABLE

USC SECURITY SYSTEM GUIDELINES 123 Technology Drive

Irvine CA 92618

tel 949.727.0373

fax 949.727.7346

COLOR CODE:

BK

BL

GR

RD

WH

= BLACK

= BLUE

= GREEN

= RED

= WHITE

EACS COMPOSITE CABLE 'L' LENEL LNL-1320

STATUS INNER CABLE 'BL' CONNECTION DETAIL

Page 15: USC SECURITY SYSTEM GUIDELINES...eacs composite cable 'l' schlage pim400-td2 power inner cable 'gy' connection detail color code: bk gr gy rd wh = black = green = gray = red = white

USC SECURITY SYSTEM GUIDELINES 123 Technology Drive

Irvine CA 92618

tel 949.727.0373

fax 949.727.7346

EACS COMPOSITE CABLE 'L' LENEL LNL-1320

REX INNER CABLE 'WH' CONNECTION DETAIL

COLOR CODE:

BL

GR

RD

WH

= BLUE

= GREEN

= RED

= WHITE

22AWG - 4 CONDUCTOR

[NON-SHIELDED]

JACKET COLOR: BLUE

BKRD

BL

BK RD

GR WH

COMPOSITE CABLE 'L'

INNER CABLE

[SPARE][SPARE]

Page 16: USC SECURITY SYSTEM GUIDELINES...eacs composite cable 'l' schlage pim400-td2 power inner cable 'gy' connection detail color code: bk gr gy rd wh = black = green = gray = red = white

TYPICAL REQUIREMENTS FOR CORNER

MOUNTED PTZ CAMERA

USC SECURITY SYSTEM GUIDELINES 123 Technology Drive

Irvine CA 92618

tel 949.727.0373

fax 949.727.7346

REFERENCE NOTES:

GENERAL NOTES:

Page 17: USC SECURITY SYSTEM GUIDELINES...eacs composite cable 'l' schlage pim400-td2 power inner cable 'gy' connection detail color code: bk gr gy rd wh = black = green = gray = red = white

TYPICAL CONDUIT REQUIREMENTS FOR DOUBLE DOOR WITH

ELECTRIFIED EXIT HARDWARE

USC SECURITY SYSTEM GUIDELINES 123 Technology Drive

Irvine CA 92618

tel 949.727.0373

fax 949.727.7346

REFERENCE NOTES:

GENERAL NOTES:

ACCESS CONTROL CABLE WIRING SCHEDULE

Page 18: USC SECURITY SYSTEM GUIDELINES...eacs composite cable 'l' schlage pim400-td2 power inner cable 'gy' connection detail color code: bk gr gy rd wh = black = green = gray = red = white

TYPICAL CONDUIT REQUIREMENTS FOR DOUBLE DOOR WITH

AUTO OPENER INTERFACE & ELECTRIFIED EXIT HARDWARE

USC SECURITY SYSTEM GUIDELINES 123 Technology Drive

Irvine CA 92618

tel 949.727.0373

fax 949.727.7346

REFERENCE NOTES:

GENERAL NOTES:

ACCESS CONTROL CABLE WIRING SCHEDULE

Page 19: USC SECURITY SYSTEM GUIDELINES...eacs composite cable 'l' schlage pim400-td2 power inner cable 'gy' connection detail color code: bk gr gy rd wh = black = green = gray = red = white

TYPICAL REQUIREMENTS FOR STOREFRONT DOUBLE DOOR

WITH ELECTRIFIED EXIT HARDWARE

USC SECURITY SYSTEM GUIDELINES 123 Technology Drive

Irvine CA 92618

tel 949.727.0373

fax 949.727.7346

ACCESS CONTROL CABLE WIRING SCHEDULE

REFERENCE NOTES:

GENERAL NOTES:

Page 20: USC SECURITY SYSTEM GUIDELINES...eacs composite cable 'l' schlage pim400-td2 power inner cable 'gy' connection detail color code: bk gr gy rd wh = black = green = gray = red = white

TYPICAL REQUIREMENTS FOR STOREFRONT DOUBLE DOOR

WITH AUTO OPENER INTERFACE & ELECTRIFIED EXIT HARDWARE

USC SECURITY SYSTEM GUIDELINES 123 Technology Drive

Irvine CA 92618

tel 949.727.0373

fax 949.727.7346

ACCESS CONTROL CABLE WIRING SCHEDULE

REFERENCE NOTES:

GENERAL NOTES:

Page 21: USC SECURITY SYSTEM GUIDELINES...eacs composite cable 'l' schlage pim400-td2 power inner cable 'gy' connection detail color code: bk gr gy rd wh = black = green = gray = red = white

TYPICAL REQUIREMENTS FOR EXTERIOR

WALL MOUNT DOME CAMERA (OPTION 1)

USC SECURITY SYSTEM GUIDELINES 123 Technology Drive

Irvine CA 92618

tel 949.727.0373

fax 949.727.7346

GENERAL NOTES:

Page 22: USC SECURITY SYSTEM GUIDELINES...eacs composite cable 'l' schlage pim400-td2 power inner cable 'gy' connection detail color code: bk gr gy rd wh = black = green = gray = red = white

TYPICAL REQUIREMENTS FOR EXTERIOR

WALL MOUNT DOME CAMERA (OPTION 2)

USC SECURITY SYSTEM GUIDELINES 123 Technology Drive

Irvine CA 92618

tel 949.727.0373

fax 949.727.7346

GENERAL NOTES:

Page 23: USC SECURITY SYSTEM GUIDELINES...eacs composite cable 'l' schlage pim400-td2 power inner cable 'gy' connection detail color code: bk gr gy rd wh = black = green = gray = red = white

TYPICAL REQUIREMENTS FOR EXTERIOR

RADIUS EMERGENCY PHONE TOWER

USC SECURITY SYSTEM GUIDELINES 123 Technology Drive

Irvine CA 92618

tel 949.727.0373

fax 949.727.7346

BACK

REFERENCE NOTES:

FOOTPRINT TO BE VERIFIED

SIDE FRONT

Page 24: USC SECURITY SYSTEM GUIDELINES...eacs composite cable 'l' schlage pim400-td2 power inner cable 'gy' connection detail color code: bk gr gy rd wh = black = green = gray = red = white

TYPICAL REQUIREMENTS FOR EXTERIOR

WALL MOUNTED EMERGENCY PHONE STATION

USC SECURITY SYSTEM GUIDELINES 123 Technology Drive

Irvine CA 92618

tel 949.727.0373

fax 949.727.7346

FRONT VIEW SIDE VIEW BACK VIEW

BOTTOM VIEW

REFERENCE NOTES:

Page 25: USC SECURITY SYSTEM GUIDELINES...eacs composite cable 'l' schlage pim400-td2 power inner cable 'gy' connection detail color code: bk gr gy rd wh = black = green = gray = red = white

TYPICAL REQUIREMENTS FOR INTERIOR

EMERGENCY PHONE FIELD STATION

USC SECURITY SYSTEM GUIDELINES 123 Technology Drive

Irvine CA 92618

tel 949.727.0373

fax 949.727.7346

PUSH FOR HELP

Page 26: USC SECURITY SYSTEM GUIDELINES...eacs composite cable 'l' schlage pim400-td2 power inner cable 'gy' connection detail color code: bk gr gy rd wh = black = green = gray = red = white

TYPICAL REQUIREMENTS FOR INTERIOR CEILING

MOUNT PTZ DOME CAMERA (OPTION 1)

USC SECURITY SYSTEM GUIDELINES 123 Technology Drive

Irvine CA 92618

tel 949.727.0373

fax 949.727.7346

GENERAL NOTE:

REFERENCE NOTE:

Page 27: USC SECURITY SYSTEM GUIDELINES...eacs composite cable 'l' schlage pim400-td2 power inner cable 'gy' connection detail color code: bk gr gy rd wh = black = green = gray = red = white

TYPICAL REQUIREMENTS FOR INTERIOR

WALL MOUNT PTZ DOME CAMERA

USC SECURITY SYSTEM GUIDELINES 123 Technology Drive

Irvine CA 92618

tel 949.727.0373

fax 949.727.7346

GENERAL NOTES:

Page 28: USC SECURITY SYSTEM GUIDELINES...eacs composite cable 'l' schlage pim400-td2 power inner cable 'gy' connection detail color code: bk gr gy rd wh = black = green = gray = red = white

TYPICAL REQUIREMENTS FOR INTERIOR CEILING

MOUNT FIXED MINI-DOME CAMERA (OPTION 2)

USC SECURITY SYSTEM GUIDELINES 123 Technology Drive

Irvine CA 92618

tel 949.727.0373

fax 949.727.7346

GENERAL NOTES:

Page 29: USC SECURITY SYSTEM GUIDELINES...eacs composite cable 'l' schlage pim400-td2 power inner cable 'gy' connection detail color code: bk gr gy rd wh = black = green = gray = red = white

TYPICAL REQUIREMENTS

REMOTE INTERCOM STATION

USC SECURITY SYSTEM GUIDELINES 123 Technology Drive

Irvine CA 92618

tel 949.727.0373

fax 949.727.7346

GENERAL NOTES:

REFERENCE NOTES:

Page 30: USC SECURITY SYSTEM GUIDELINES...eacs composite cable 'l' schlage pim400-td2 power inner cable 'gy' connection detail color code: bk gr gy rd wh = black = green = gray = red = white

DURESS HELP BUTTON MOUNTING CONFIGURATIONS

USC SECURITY SYSTEM GUIDELINES 123 Technology Drive

Irvine CA 92618

tel 949.727.0373

fax 949.727.7346

WALL MOUNTED DURESS SWITCH DETAIL

1

UNDER COUNTER MOUNT DETAIL

2

MOUNTING KNEEWELL MOUNT SWITCH DETAIL

3

Page 31: USC SECURITY SYSTEM GUIDELINES...eacs composite cable 'l' schlage pim400-td2 power inner cable 'gy' connection detail color code: bk gr gy rd wh = black = green = gray = red = white

TYPICAL CEILING TILE MOUNT GLASS BREAK DETECTOR

USC SECURITY SYSTEM GUIDELINES 123 Technology Drive

Irvine CA 92618

tel 949.727.0373

fax 949.727.7346

GENERAL NOTES:

Page 32: USC SECURITY SYSTEM GUIDELINES...eacs composite cable 'l' schlage pim400-td2 power inner cable 'gy' connection detail color code: bk gr gy rd wh = black = green = gray = red = white

MOTORIZED SLIDING DOOR

USC SECURITY SYSTEM GUIDELINES 123 Technology Drive

Irvine CA 92618

tel 949.727.0373

fax 949.727.7346

REFERENCE NOTES: GENERAL NOTES:

Page 33: USC SECURITY SYSTEM GUIDELINES...eacs composite cable 'l' schlage pim400-td2 power inner cable 'gy' connection detail color code: bk gr gy rd wh = black = green = gray = red = white

TYPICAL REQUIREMENTS FOR PEDESTRIAN GATE

WITH MORTISE LOCK

USC SECURITY SYSTEM GUIDELINES 123 Technology Drive

Irvine CA 92618

tel 949.727.0373

fax 949.727.7346

GENERAL NOTES:

REFERENCE NOTE:

Page 34: USC SECURITY SYSTEM GUIDELINES...eacs composite cable 'l' schlage pim400-td2 power inner cable 'gy' connection detail color code: bk gr gy rd wh = black = green = gray = red = white

TYPICAL REQUIREMENTS FOR PEDESTRIAN GATE

WITH EXIT HARDWARE

USC SECURITY SYSTEM GUIDELINES 123 Technology Drive

Irvine CA 92618

tel 949.727.0373

fax 949.727.7346

GENERAL NOTES:

REFERENCE NOTE:

ACCESS CONTROL CABLE WIRING SCHEDULE

Page 35: USC SECURITY SYSTEM GUIDELINES...eacs composite cable 'l' schlage pim400-td2 power inner cable 'gy' connection detail color code: bk gr gy rd wh = black = green = gray = red = white

TYPICAL REQUIREMENTS FOR POLE MOUNTED CAMERA

USC SECURITY SYSTEM GUIDELINES 123 Technology Drive

Irvine CA 92618

tel 949.727.0373

fax 949.727.7346

REFERENCE NOTES:

Page 36: USC SECURITY SYSTEM GUIDELINES...eacs composite cable 'l' schlage pim400-td2 power inner cable 'gy' connection detail color code: bk gr gy rd wh = black = green = gray = red = white
Page 37: USC SECURITY SYSTEM GUIDELINES...eacs composite cable 'l' schlage pim400-td2 power inner cable 'gy' connection detail color code: bk gr gy rd wh = black = green = gray = red = white
Page 38: USC SECURITY SYSTEM GUIDELINES...eacs composite cable 'l' schlage pim400-td2 power inner cable 'gy' connection detail color code: bk gr gy rd wh = black = green = gray = red = white
Page 39: USC SECURITY SYSTEM GUIDELINES...eacs composite cable 'l' schlage pim400-td2 power inner cable 'gy' connection detail color code: bk gr gy rd wh = black = green = gray = red = white

TYPICAL REQUIREMENTS FOR ROLL UP DOOR WITH

DOOR POSITION SWITCH

USC SECURITY SYSTEM GUIDELINES 123 Technology Drive

Irvine CA 92618

tel 949.727.0373

fax 949.727.7346

REFERENCE NOTE:

ACCESS CONTROL CABLE WIRING SCHEDULE

GENERAL NOTES:

Page 40: USC SECURITY SYSTEM GUIDELINES...eacs composite cable 'l' schlage pim400-td2 power inner cable 'gy' connection detail color code: bk gr gy rd wh = black = green = gray = red = white

TYPICAL REQUIREMENTS FOR SINGLE DOOR WITH

ELECTRIFIED MORTISE HARDWARE

USC SECURITY SYSTEM GUIDELINES 123 Technology Drive

Irvine CA 92618

tel 949.727.0373

fax 949.727.7346

ACCESS CONTROL CABLE WIRING SCHEDULE

GENERAL NOTES:

REFERENCE NOTES:

Page 41: USC SECURITY SYSTEM GUIDELINES...eacs composite cable 'l' schlage pim400-td2 power inner cable 'gy' connection detail color code: bk gr gy rd wh = black = green = gray = red = white

TYPICAL REQUIREMENTS FOR SINGLE DOOR WITH

ELECTRIFIED EXIT HARDWARE

USC SECURITY SYSTEM GUIDELINES 123 Technology Drive

Irvine CA 92618

tel 949.727.0373

fax 949.727.7346

ACCESS CONTROL CABLE WIRING SCHEDULE

GENERAL NOTES:

REFERENCE NOTES:

Page 42: USC SECURITY SYSTEM GUIDELINES...eacs composite cable 'l' schlage pim400-td2 power inner cable 'gy' connection detail color code: bk gr gy rd wh = black = green = gray = red = white

TYPICAL REQUIREMENTS FOR SINGLE DOOR WITH

AUTO OPENER INTERFACE & ELECTRIFIED EXIT HARDWARE

USC SECURITY SYSTEM GUIDELINES 123 Technology Drive

Irvine CA 92618

tel 949.727.0373

fax 949.727.7346

ACCESS CONTROL CABLE WIRING SCHEDULE

REFERENCE NOTES:

GENERAL NOTES:

Page 43: USC SECURITY SYSTEM GUIDELINES...eacs composite cable 'l' schlage pim400-td2 power inner cable 'gy' connection detail color code: bk gr gy rd wh = black = green = gray = red = white

TYPICAL REQUIREMENTS FOR SINGLE DOOR WITH

AUTO OPENER INTERFACE & ELECTRIFIED MORTISE LOCK

USC SECURITY SYSTEM GUIDELINES 123 Technology Drive

Irvine CA 92618

tel 949.727.0373

fax 949.727.7346

ACCESS CONTROL CABLE WIRING SCHEDULE

REFERENCE NOTES:

GENERAL NOTES:

Page 44: USC SECURITY SYSTEM GUIDELINES...eacs composite cable 'l' schlage pim400-td2 power inner cable 'gy' connection detail color code: bk gr gy rd wh = black = green = gray = red = white

TYPICAL REQUIREMENTS FOR SINGLE DOOR WITH

AUTO OPENER INTERFACE & ELECTRIC STRIKE LOCK

USC SECURITY SYSTEM GUIDELINES 123 Technology Drive

Irvine CA 92618

tel 949.727.0373

fax 949.727.7346

ACCESS CONTROL CABLE WIRING SCHEDULE

REFERENCE NOTES:

GENERAL NOTES:

Page 45: USC SECURITY SYSTEM GUIDELINES...eacs composite cable 'l' schlage pim400-td2 power inner cable 'gy' connection detail color code: bk gr gy rd wh = black = green = gray = red = white

TYPICAL REQUIREMENTS FOR STOREFRONT SINGLE DOOR

WITH ELECTRIFIED EXIT HARDWARE

USC SECURITY SYSTEM GUIDELINES 123 Technology Drive

Irvine CA 92618

tel 949.727.0373

fax 949.727.7346

ACCESS CONTROL CABLE WIRING SCHEDULE

GENERAL NOTES:

REFERENCE NOTES:

Page 46: USC SECURITY SYSTEM GUIDELINES...eacs composite cable 'l' schlage pim400-td2 power inner cable 'gy' connection detail color code: bk gr gy rd wh = black = green = gray = red = white

TYPICAL REQUIREMENTS FOR STOREFRONT SINGLE DOOR

WITH AUTO OPENER INTERFACE & ELECTRIFIED EXIT HARDWARE

USC SECURITY SYSTEM GUIDELINES 123 Technology Drive

Irvine CA 92618

tel 949.727.0373

fax 949.727.7346

ACCESS CONTROL CABLE WIRING SCHEDULE

REFERENCE NOTES:

GENERAL NOTES:

Page 47: USC SECURITY SYSTEM GUIDELINES...eacs composite cable 'l' schlage pim400-td2 power inner cable 'gy' connection detail color code: bk gr gy rd wh = black = green = gray = red = white

TYPICAL REQUIREMENTS FOR SLIDE GATE WITH

GATE POSITION SWITCH

USC SECURITY SYSTEM GUIDELINES 123 Technology Drive

Irvine CA 92618

tel 949.727.0373

fax 949.727.7346

REFERENCE NOTES:

ACCESS CONTROL CABLE WIRING SCHEDULE

GENERAL NOTES:

Page 48: USC SECURITY SYSTEM GUIDELINES...eacs composite cable 'l' schlage pim400-td2 power inner cable 'gy' connection detail color code: bk gr gy rd wh = black = green = gray = red = white

TYPICAL SECURITY TERMINAL CABINET (STC) CONFIGURATION

USC SECURITY SYSTEM GUIDELINES 123 Technology Drive

Irvine CA 92618

tel 949.727.0373

fax 949.727.7346

REFERENCE NOTES:

GENERAL NOTES:

Page 49: USC SECURITY SYSTEM GUIDELINES...eacs composite cable 'l' schlage pim400-td2 power inner cable 'gy' connection detail color code: bk gr gy rd wh = black = green = gray = red = white

TYPICAL REQUIREMENTS FOR STC, POWER SUPPLY

AND DOOR POWER SUPPLY COVERS

STC ENCLOSURE COVER

1

POWER SUPPLY COVER

2

DOOR POWER SUPPLY COVER

3

USC SECURITY SYSTEM GUIDELINES 123 Technology Drive

Irvine CA 92618

tel 949.727.0373

fax 949.727.7346

REFERENCE NOTES: