update of detector hall in mountain region
DESCRIPTION
Update of detector hall in mountain region. May 22, 2011 @LAL-Orsay Y.Sugimoto. Sample site. Exp-hall. Access tunnel. Shape of cavern. Study of 2 sample sites in Japan Both sites have very good geology of granite Depth of the cavern is less than 300m - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: Update of detector hall in mountain region](https://reader035.vdocuments.site/reader035/viewer/2022062517/568131cd550346895d983622/html5/thumbnails/1.jpg)
1
May 22, 2011 @LAL-Orsay
Y.Sugimoto
Update of detector hall in mountain region
![Page 2: Update of detector hall in mountain region](https://reader035.vdocuments.site/reader035/viewer/2022062517/568131cd550346895d983622/html5/thumbnails/2.jpg)
2
Sample site
Exp-hallAcc
ess
tunn
el
![Page 3: Update of detector hall in mountain region](https://reader035.vdocuments.site/reader035/viewer/2022062517/568131cd550346895d983622/html5/thumbnails/3.jpg)
3
Shape of cavern
• Study of 2 sample sites in Japan– Both sites have very good geology of granite– Depth of the cavern is less than 300m
Shape of the cavern can be bullet shape rather than egg shape
B eam line
R 1 5 m
21 m
1 9m
2 0 0 ton x2
9m
2 00 to n x2
Beam line
19m
2 5m
![Page 4: Update of detector hall in mountain region](https://reader035.vdocuments.site/reader035/viewer/2022062517/568131cd550346895d983622/html5/thumbnails/4.jpg)
4
Access tunnel• Location of solenoid construction
– In the cavern larger cavern (L~40m?), smaller access tunnel– On surface smaller cavern, larger access tunnel– Cost is similar for both cases, but on-surface assembly is more
convenient and less risk On-surface assembly with large (h=11m) access tunnel
• Access tunnel to 2nd detector– It has to go underneath the BDS tunnel, and should not be so large – Smaller access tunnel for the 2nd detector (SiD?)– Solenoid of the 2nd detector should be carried through the larger access
tunnel, and go through the area of the 1st detector– What is the minimum size of the smaller access tunnel (input from SiD)?
• Helium compressor for solenoids– He compressors can be placed in the large access tunnel – Distance between the detector solenoid and the compressor < 200m (?)– KEK cryogenic group (Y.Makida et al.) has joined this study
![Page 5: Update of detector hall in mountain region](https://reader035.vdocuments.site/reader035/viewer/2022062517/568131cd550346895d983622/html5/thumbnails/5.jpg)
5
Solenoid transport
- 225t/5axles 450t with 2-trailers- Capable of ~7% slope
![Page 6: Update of detector hall in mountain region](https://reader035.vdocuments.site/reader035/viewer/2022062517/568131cd550346895d983622/html5/thumbnails/6.jpg)
6
Solenoid transport
100m25m
15m
Detector Service Cavern
25m
Main tunnel
11m
m
Duct tunnel
110m
m
A B C D E
A’ B’ C’ D’ E’
7.2m
to Damping Ring
25m
2 0m
3m
9m
20 0 ton x2
8.5m
Enough space fordetector solenoids
![Page 7: Update of detector hall in mountain region](https://reader035.vdocuments.site/reader035/viewer/2022062517/568131cd550346895d983622/html5/thumbnails/7.jpg)
7
Other issues
• Detector service caverns– What is the required size to enclose detector power
supplies, cooling plants for the detectors, power supplies and refrigerators for solenoids, etc?
• Beam line height?– To be decided in this workshop
• Do we need service tunnel and survey tunnel for accelerator?
• Can we share the access tunnel for detectors with accelerator (DR, BDS)?
![Page 8: Update of detector hall in mountain region](https://reader035.vdocuments.site/reader035/viewer/2022062517/568131cd550346895d983622/html5/thumbnails/8.jpg)
8
Earthquake • Belle detector after 3.11
– Bell detector was rolled out from the beam line and fixed to the ground
– 32 fixing bolts (M22) have been broken by the earthquake, and Belle detector moved 6 cm on the rail
• How should platforms be supported on the occasion of big earthquake? – Move with the ground?– Isolated from the ground?
Seismic isolation supportfor buildings
![Page 9: Update of detector hall in mountain region](https://reader035.vdocuments.site/reader035/viewer/2022062517/568131cd550346895d983622/html5/thumbnails/9.jpg)
9
Earthquake
• Isolation from the ground can be achieved using air-pads, but– Enough gap between side wall is necessary– Positioning actuators should be retractable– Very flexible bellows should be placed between QD0 and
QF1 to avoid damages to the inner detectors
Earthquake EarlyWarning (EEW) signal
Our own P-wave sensors
High pressureair/nitrogen vessel
Air-pads
Platform
![Page 10: Update of detector hall in mountain region](https://reader035.vdocuments.site/reader035/viewer/2022062517/568131cd550346895d983622/html5/thumbnails/10.jpg)
10
Towards DBD
• Impact of 3.11– Some collaborators of KEK who belong to facility
group, cryogenic group, Acc. group are occupied with repairing works at KEK and JPARC
– Hopefully, they will come back to ILC work by autumn
• In cooperation with the experts mentioned above, we will make designs necessary for the mountain site:– Underground cavern and the access tunnel– Detector solenoid/cryogenic system– Other utilities
![Page 11: Update of detector hall in mountain region](https://reader035.vdocuments.site/reader035/viewer/2022062517/568131cd550346895d983622/html5/thumbnails/11.jpg)
11
backup
![Page 12: Update of detector hall in mountain region](https://reader035.vdocuments.site/reader035/viewer/2022062517/568131cd550346895d983622/html5/thumbnails/12.jpg)
12
RDR