ANALYSIS OF HEAD LENGTH EFFECT OF WIRE ROPE SENSOR ON OUTPUT VOLTAGE

NOOR HASMIZA BT HARUN

FK 2008 12

Page 2: UNIVERSITI PUTRA MALAYSIA ANALYSIS OF HEAD LENGTH …psasir.upm.edu.my/id/eprint/5393/1/FK_2008_12.pdfuniversiti putra malaysia . analysis of head length effect of wire rope sensor

ANALYSIS OF HEAD LENGTH EFFECT OF WIRE ROPE SENSOR ON OUTPUT VOLTAGE

By

NOOR HASMIZA BT HARUN

Thesis Submitted to the School of Graduate Studies, Universiti Putra Malaysia in Fulfilment of the Requirements for the Degree of Master of Science

April 2008

Page 3: UNIVERSITI PUTRA MALAYSIA ANALYSIS OF HEAD LENGTH …psasir.upm.edu.my/id/eprint/5393/1/FK_2008_12.pdfuniversiti putra malaysia . analysis of head length effect of wire rope sensor

Dedication

TO MAK, ABAH AND FAMILY

ESPECIALLY TO MY HUSBAND, ROZAIMI ABDUL JALIL AND DAUGHTER, SUFIYA DINA IMANI

ii

Page 4: UNIVERSITI PUTRA MALAYSIA ANALYSIS OF HEAD LENGTH …psasir.upm.edu.my/id/eprint/5393/1/FK_2008_12.pdfuniversiti putra malaysia . analysis of head length effect of wire rope sensor

Abstract of thesis presented to the Senate of Universiti Putra Malaysia in fulfilment of the requirement for the degree of Master of Science

ANALYSIS OF HEAD LENGTH EFFECT OF WIRE ROPE SENSOR

ON OUTPUT VOLTAGE

By

NOOR HASMIZA BINTI HARUN

April 2008 Chairman: Norhisam Misron, PhD Faculty: Engineering

Wire rope are used extensively in industrial applications involving lifting machines

such as lift system, cable car system as well as crane services. In many cases, failure

of a wire rope could lead to expensive damage to equipment or even to loss of life.

Structural integrity of the wire rope is to be monitored to safe guard human lives.

Regular periodic inspection is necessary for optimum safe utilization.

Apart from visual inspection, the non destructive test methods are available to check

the condition of this wire rope. Various methods have been used for wire rope testing

such as eddy current, ultrasonic and radiographic. However, each method has some

drawbacks in their application.

Currently, there is no specific tool to design the wire rope sensor. Trial and error

method was used to design the wire rope sensor and it will consume longer time for

prototyping and fabricating the sensor. This method does not offer rapid performance

evaluation of the designed sensor and it will cause the process of improving the

efficiency of the sensor will be slower. Therefore, development of a model to design

iii

Page 5: UNIVERSITI PUTRA MALAYSIA ANALYSIS OF HEAD LENGTH …psasir.upm.edu.my/id/eprint/5393/1/FK_2008_12.pdfuniversiti putra malaysia . analysis of head length effect of wire rope sensor

the wire rope sensor has been proposed. This model is able to investigate variable

parameter involved in designing the wire rope sensor and it will speeding the process

of prototyping the wire rope sensor.

In this research, a fabricated wire rope sensor based on electromagnetism principles

has been analyzed. The sensor applies the theory of magnetic circuit for the crack

detection operation. This is an added feature to the sensor as the magnetic circuit

does not need any energy supply to be energized which indirectly reduces its energy

consumption. This sensor is a passive type sensor and its structure is very simple. It

is made up of three main components; sensor head, center yoke rounded with copper

wire and a set of permanent magnet. The sensor will only produce a signal when

there is a relative movement between the sensor head and the tested wire rope.

Derivations of theoretical calculations using permeance method was done to obtain a

tools that manages to study the physical structures behaviors of the sensor. Finite

Element Method (FEM) simulations and laboratory experiments have been

conducted to observe the effects of head length to the output voltage of the sensor.

The objective of this research is to perform the analysis of head length, Lh effect of

wire rope sensor on output voltage was successfully achieved. A theoretical equation

for the voltage induced by the sensor has been deduced using permeance method.

Finite Element Method (FEM) simulation and laboratory experiments were done to

observe the effects of head length of the sensor head to the output voltage of the

sensor. Comparison between simulation result, theoretical calculation and laboratory

iv

Page 6: UNIVERSITI PUTRA MALAYSIA ANALYSIS OF HEAD LENGTH …psasir.upm.edu.my/id/eprint/5393/1/FK_2008_12.pdfuniversiti putra malaysia . analysis of head length effect of wire rope sensor

experiment shows almost identical results. The analysis is necessary to obtain the

best design for the wire rope sensor that would produce high output voltage.

v

Page 7: UNIVERSITI PUTRA MALAYSIA ANALYSIS OF HEAD LENGTH …psasir.upm.edu.my/id/eprint/5393/1/FK_2008_12.pdfuniversiti putra malaysia . analysis of head length effect of wire rope sensor

Abstrak thesis yang dikemukakan kepada Senat Universiti Putra Malaysia sebagai memenuhi keperluan untuk ijazah Master Sains

ANALISIS KESAN PANJANG MATA PENGESAN WAYAR KABEL KEPADA VOLTAN KELUARAN

Oleh

NOOR HASMIZA BT HARUN

April 2008

Pengerusi: Norhisam Misron, PhD Fakulti: Kejuruteraan Wayar kabel digunakan secara meluas dalam aplikasi industri seperti elevator, lif,

kereta kabel dan kren. Dalam beberapa kes, kegagalan wayar kabel boleh

mengakibatkan kerosakan kepada peralatan mahupun nyawa manusia. Keutuhan

struktur wayar kabel haruslah dipantau untuk keselamatan manusia. Pemeriksaan

berterusan adalah perlu untuk mengoptimumkan keselamatan.

Selain daripada pemeriksaan visual, kaedah ujian tanpa kerosakan juga digunakan

untuk memeriksa keadaan wayar kabel. Pelbagai kaedah telah digunakan untuk

pemeriksaan wayar kabel seperti arus “eddy”, ultrasonic dan radiografi.

Walaubagaimanapun, setiap kaedah mempunyai kelemahan dalam aplikasi.

Sekarang ini, tiada kaedah spesifik untuk mereka pengesan wayar kabel. Kaedah

cuba dan salah telah digunakan untuk mereka pengesan wayar kabel dan ia

menggunakan banyak masa untuk membuat protaip dan fabrikasi pengesan tersebut.

Kaedah ini tidak menawarkan penilaian prestasi pantas dan ini akan menyebabkan

vi

Page 8: UNIVERSITI PUTRA MALAYSIA ANALYSIS OF HEAD LENGTH …psasir.upm.edu.my/id/eprint/5393/1/FK_2008_12.pdfuniversiti putra malaysia . analysis of head length effect of wire rope sensor

proses meningkatkan kecekapan pengesan akan menjadi lambat. Oleh sebab itu,

pembangunan sebuah model untuk mereka pengesan wayar kabel telah dicadangkan.

Model ini berupaya untuk memeriksa pelbagai parameter yang digunakan untuk

mereka pengesan wayar kabel dan ini akan mempercepatkan proses membuat

prototaip pengesan wayar kabel.

Dalam kajian ini, pengesan wayar kabel berasaskan prinsip elektromagnet telah

dianalisa. Ia menggunakan teori litar magnet untuk operasi mengesan keretakan.

Pengesan ini tidak memerlukan bekalan kuasa dan secara tidak langsung akan

mengurangkan penggunaan kuasa. Pengesan ini adalah pasif dan strukturnya ringkas.

Ia terdiri daripada tiga komponen penting: mata pengesan, tiang tengah yang

dikelilingi dengan wayar kuprum dan juga sepasang magnet kekal. Pengesan ini

hanya akan mengeluarkan isyarat jika terdapat pergerakan di antara mata pengesan

dan wayar kabel.

Pembuktian pengiraan secara teori menggunakan kaedah galangan telah dijalankan

untuk mendapatkan alat yang mampu mengkaji sifat struktur fizikal pengesan

tersebut. Simulasi FEM dan eksperimen makmal telah dilakukan untuk melihat kesan

panjang mata kepada voltan keluaran pengesan.

Objektif penyelidikan ini adalah untuk melaksanakan analisa kesan panjang mata

pengesan wayar kabel kepada voltan keluaran telah berjaya dicapai. Pengiraan secara

teori untuk voltan keluaran telah diperolehi menggunakan kaedah galangan. Simulasi

FEM telah dilakukan untuk melihat kesan mata pengesan kepada voltan keluaran

pengesan wayar kabel ini. Perbandingan di antara keputusan yang diperolehi

vii

Page 9: UNIVERSITI PUTRA MALAYSIA ANALYSIS OF HEAD LENGTH …psasir.upm.edu.my/id/eprint/5393/1/FK_2008_12.pdfuniversiti putra malaysia . analysis of head length effect of wire rope sensor

daripada simulasi FEM, pengiraan teori dan eksperimen makmal memberikan

keputusan yang sama. Analisis ini adalah perlu untuk mendapatkan rekabentuk

terbaik pengesan wayar kabel yang yang boleh menghasilkan keluaran voltan yang

tinggi.

viii

Page 10: UNIVERSITI PUTRA MALAYSIA ANALYSIS OF HEAD LENGTH …psasir.upm.edu.my/id/eprint/5393/1/FK_2008_12.pdfuniversiti putra malaysia . analysis of head length effect of wire rope sensor

ACKNOWLEDGEMENTS All praise to supreme almighty Allah swt. the only creator, cherisher, sustainer and

efficient assembler of the world and galaxies whose blessings and kindness have

enabled the author to accomplish this project successfully.

The author gratefully acknowledges the guidance, advice, support and

encouragement she received from her supervisor, Dr. Norhisam Misron who keeps

advising and commenting throughout this project until it turns to real success.

Great appreciation is expressed to Associate Professor Dr. Ishak Aris for his valuable

remarks, help advice and encouragement.

Appreciation also to the Faculty of Engineering for providing the facilities and the

components required for undertaking this project.

ix

Page 11: UNIVERSITI PUTRA MALAYSIA ANALYSIS OF HEAD LENGTH …psasir.upm.edu.my/id/eprint/5393/1/FK_2008_12.pdfuniversiti putra malaysia . analysis of head length effect of wire rope sensor

I certify that an Examination Committee met on (April, 3rd 2008) to conduct the final examination of Noor Hasmiza Harun on her Master of Science thesis entitled “Analysis of head length effect of wire rope sensor on output voltage” in accordance with University Putra Malaysia (Higher Degree) Act 1980 and University Pertanian Malaysia (Higher Degree) Regulations 1981. The Committee recommends that the candidate be awarded the relevant degree. Members of the Examination Committee are as follows:

Prof. Dr. Sudhanshu Shekhar Jamuar Faculty of Engineering University Putra Malaysia (Chairman) Assoc. Prof. Dr. Senan Mahmod Faculty of Engineering University Putra Malaysia (Member) Dr. Syed Javaid Iqbal Faculty of Engineering University Putra Malaysia (Member) Prof. Dr. Syed Idris Syed Hassan Pusat Pengajian Elektrikal dan Elektronik Kampus Kejuruteraan Universiti Sains Malaysia (Member) ___________________________________

Prof. Dr. Hasanah Mohd Ghazali Deputy Dean School of Graduate Studies Universiti Putra Malaysia

Date:

x

Page 12: UNIVERSITI PUTRA MALAYSIA ANALYSIS OF HEAD LENGTH …psasir.upm.edu.my/id/eprint/5393/1/FK_2008_12.pdfuniversiti putra malaysia . analysis of head length effect of wire rope sensor

This thesis was submitted to the Senate of University Putra Malaysia and has been accepted as fulfilment of the requirement for the degree of Master of Science. The members of the Supervisory Committee were as follows:

Dr. Norhisam Misron Faculty of Engineering University Putra Malaysia (Chairman) Assoc. Prof. Dr. Ishak Aris Faculty of Engineering University Putra Malaysia (Member)

_____________________________

AINI IDERIS, PhD Professor and Dean School of Graduate Studies Universiti Putra Malaysia

Date:12 June 2008

xi

Page 13: UNIVERSITI PUTRA MALAYSIA ANALYSIS OF HEAD LENGTH …psasir.upm.edu.my/id/eprint/5393/1/FK_2008_12.pdfuniversiti putra malaysia . analysis of head length effect of wire rope sensor

xii

DECLARATION

I declare that the thesis is my original work except for quotations and citations which have been duly acknowledged. I also declare that it has not been previously, and is not concurrently submitted for any other degree at UPM or other institutions.

_______________________________NOOR HASMIZA BT HARUN

Date: 23 May 2008

Page 14: UNIVERSITI PUTRA MALAYSIA ANALYSIS OF HEAD LENGTH …psasir.upm.edu.my/id/eprint/5393/1/FK_2008_12.pdfuniversiti putra malaysia . analysis of head length effect of wire rope sensor

TABLE OF CONTENTS

Page

DEDICATION ii ABSTRACT iii ABSTRAK vi ACKNOWLEDGEMENTS ix APPROVAL x DECLARATION xii LIST OF FIGURES xv LIST OF ABBREVIATIONS xix

CHAPTER

I INTRODUCTION 1 1.1 Background of the Wire Rope Sensor 1 1.2 Problem Statement 3 1.3 Objectives 5 1.4 Scope of Study 6 1.5 Contributions 8 1.6 Thesis layout 8

II LITERATURE REVIEW 10 2.1 An overview of related works 10 2.2 Basic formula related to theoretical equations

derivations 17

2.2.1 The Faraday’s Law 17 2.2.2 Magnetic Circuit Analysis 18 2.2.3 Permeance Method 19 2.3 Finite Element Method 22 2.4 Microcal Origin 7.5 26 2.5 Properties of Permanent Magnets 28 2.5.1 Alnico 29 2.5.2 Ferrites 29 2.5.3 Rare-Earth Permanent Magnets 30 2.6 Basic principle of wire rope sensor 32 2.7 Summary 33

III METHODOLOGY 34 3.1 System of wire rope sensor 35 3.2 Wire rope sensor specification 37 3.3 Derivation of theoretical equation using permeance

method 39

xiii

Page 15: UNIVERSITI PUTRA MALAYSIA ANALYSIS OF HEAD LENGTH …psasir.upm.edu.my/id/eprint/5393/1/FK_2008_12.pdfuniversiti putra malaysia . analysis of head length effect of wire rope sensor

3.4 Finite Element Method (FEM) Simulation 45 3.4.1 Modeling using FEM 45 3.4.2 Designed parameter in FEM simulation 51 3.5 Summary 52 IV RESULTS AND DISCUSSION 53 4.1 Analysis on the derived equation using permeance

method 53

4.1.1 Effects of width and length of P1 54 4.1.2 Effects of coil gap 55 4.1.3 Effects of width and length of P2 56 4.1.4 Effects of head length gap 58 4.1.5 Effects of diameter of the wire rope 59 4.1.6 Effects of length of the crack , Lc 60 4.1.7 Effects of gap of the Pcr 61 4.2 FEM Simulation Result 63 4.2.1 Air gap effects 63 4.2.2 Coil gap effects 66 4.2.3 Back yoke saturation effects 68 4.2.4 Effects of head length to the output voltage in

FEM 70

4.3 Effects of head length, Lh to the output voltage of the wire rope sensor

71

4.4 Comparison of results from simulation, theoretical calculation and measurement

78

4.5 Summary 79

V CONCLUSION AND SUGGESTIONS FOR FUTURE WORK

81

5.1 Conclusion 81 5.2 Suggestions and Future Work Recommendation 83

REFERENCES 84 BIODATA OF THE AUTHOR 89 LIST OF PUBLICATIONS 90

xiv

Page 16: UNIVERSITI PUTRA MALAYSIA ANALYSIS OF HEAD LENGTH …psasir.upm.edu.my/id/eprint/5393/1/FK_2008_12.pdfuniversiti putra malaysia . analysis of head length effect of wire rope sensor

LIST OF FIGURES

Figure Page

2.1 Experiment setup for eddy current based crack detection sensor 11

2.2 Transducer structure used in magnetic sensing sensor 13

2.3 Magnetic flaw apparatus used for elevator inspection 14

2.4 Meraster MD-20 Tester 15

2.5 Meraster MD-120 Defectograph and its measuring head 16

2.6 Simple magnetic circuit 19

2.7 Magnetic circuit with an air gap 21

2.8 Magnetic equivalent circuit 21

2.9 Microcal Origin 7.5 26

2.10 Demagnetization curves for different permanent magnet materials

28

2.11 Flux linkages for designed wire rope 33

3.1 Research methodology wire rope sensor system 34

3.2 Modeling structure of the wire rope sensor 36

3.3 Block diagram of the wire rope sensor system 36

3.4 The constructed wire rope sensor 38

3.5 Permeance model of the wire rope sensor 40

3.6 Magnetic equivalent circuit of wire rope sensor 41

3.7 Modeling for θc calculation 44

3.8 Flow chart of the simulation process using FEM 46

3.9 Modeling structure of wire rope sensor in Microcal Origin 47

3.10 The msk , blk and bod file 48

3.11 Mesh calculation 49

xv

Page 17: UNIVERSITI PUTRA MALAYSIA ANALYSIS OF HEAD LENGTH …psasir.upm.edu.my/id/eprint/5393/1/FK_2008_12.pdfuniversiti putra malaysia . analysis of head length effect of wire rope sensor

3.12 The fra and config file 49

3.13 Flux potential for the modeled wire rope sensor 50

3.14 Flux density for the modeled wire rope sensor 50

3.15 Designed parameter used in FEM simulation 51

4.1 Effects of w1 and l1 to the voltage induced by the wire rope sensor

54

4.2 Effects of gc to the voltage induced by the wire rope sensor 56

4.3 Effects of w2 and l2 to the voltage induced by the wire rope sensor

57

4.4 Effect of ghl to the voltage induced by the wire rope sensor 58

4.5 Maximum output voltage versus head length 59

4.6 Effect of D to the voltage induced by the wire rope sensor 60

4.7 Effect of Lc to the voltage induced by the wire rope sensor 61

4.8 Effect of G to the voltage induced by the wire rope sensor 62

4.9 Modeling of wire rope sensor used to observe the effects of head length gap

64

4.10 Flux linkages at different air gap for various type of head length 64

4.11 Maximum flux linkages at different air gap for various type of head length

65

4.12 Maximum flux linkages for air gap, g = 20mm and g=30mm 65

4.13 Modeling of wire rope sensor used to observe the effects of coil gap

66

4.14 Maximum flux linkages at different coil gap for various type of head length

67

4.15 Maximum flux linkages for various coil gap configuration 67

4.16 Modeling of wire rope sensor used to observe saturation effects 68

4.17 Comparison between saturated and non saturated flux linkages at g = 20mm

69

4.18 Comparison between saturated and non saturated flux linkages at g = 30mm

69

xvi

Page 18: UNIVERSITI PUTRA MALAYSIA ANALYSIS OF HEAD LENGTH …psasir.upm.edu.my/id/eprint/5393/1/FK_2008_12.pdfuniversiti putra malaysia . analysis of head length effect of wire rope sensor

4.19 Maximum voltage versus head length for g=30mm 70

4.20 Experiment setup for wire rope sensor 71

4.21 Voltage versus time for laser displacement sensor and wire rope sensor

72

4.22 Distance versus time for laser displacement sensor and voltage versus time for wire rope sensor

73

4.23 Derivatives of distance per time for laser displacement sensor 74

4.24 Maximum voltage versus speed for wire rope with diameter of 5 mm

75

4.25 Maximum voltage versus speed for wire rope with diameter of 7.5 mm

75

4.26 Maximum voltage versus speed for wire rope with diameter of 10 mm

76

4.27 Maximum voltage versus diameter of wire rope at a speed of 1m/s

77

4.28 Graph of comparison between FEM, calculation and experiment

78

xvii

Page 19: UNIVERSITI PUTRA MALAYSIA ANALYSIS OF HEAD LENGTH …psasir.upm.edu.my/id/eprint/5393/1/FK_2008_12.pdfuniversiti putra malaysia . analysis of head length effect of wire rope sensor

LIST OF ABBREVIATIONS

Lh Head length

ghl Head length gap

gc Coil gap

0μ Permeability of air = 4π x 10-7

P1 Permeance between coil gap

P2 Permeance between head length gap

P3 Permeance at the wire rope

Pc Permeance at the crack

Pcy Permeance at cylinder

Pr Permeance at ring

w1 Width of the P1

l1 Length of the P1

w2 Width of the P2

l2 Length of the P2

D Diameter of the wire rope

Lc Length of the crack

G Gap of the ring

Vs Supply voltage

B Magnetic density

φt Total flux flowing

A Magnetic area

It Total current

φ1 Flux flowing at P1

φ2 Flux flowing at P2

φ3 Flux flowing at P3

xviii

Page 20: UNIVERSITI PUTRA MALAYSIA ANALYSIS OF HEAD LENGTH …psasir.upm.edu.my/id/eprint/5393/1/FK_2008_12.pdfuniversiti putra malaysia . analysis of head length effect of wire rope sensor

ℜ1 Reluctance of P1

ℜ2 Reluctance of P2

ℜ3 Reluctance of P3

θc Angle of crack = x/35

V Output voltage of the wire rope sensor

N Number of coil turn

xix

t3

∂∂φ

Flux changes per second

Page 21: UNIVERSITI PUTRA MALAYSIA ANALYSIS OF HEAD LENGTH …psasir.upm.edu.my/id/eprint/5393/1/FK_2008_12.pdfuniversiti putra malaysia . analysis of head length effect of wire rope sensor

CHAPTER 1

INTRODUCTION

1.1 Background of the Wire Rope Sensor

Wire ropes are used widely in industrial applications such as elevators, lift system,

cable car system and crane services (Park and Park, 2002) and are often safety-

critical components. In many cases failure of a wire rope could lead to expensive

damage to equipment or even to loss of life (Yangsheng, Hanmin and Shuzi, 1988).

Due to the long duration usage, surface as well as the internal of wire ropes may have

defects (Zawada, 1999). Therefore, there is an obvious need to check the condition

of the wire ropes regularly to avoid any fatal accident due to its internal flaw

(Moriya, Sugawara and Tsukada, 2004).

A recent statistical of over 8000 laboratory and field test records indicates that visual

wire rope inspections are frequently unreliable, and that visual methods must be

considered, in many cases, questionable as a sole means of inspection (Weischedel,

1990). Apart from visual inspection, the non destructive test methods are available to

check the condition of these wire ropes (Placko and Dufour, 1993). Various methods

have been used for wire rope testing such as eddy current, ultrasonic and

radiographic. However, each method has some drawbacks in their application.

Eddy current method, for example, works on the transformer principles, making this

method complex. The sensor is based on the induction of voltage in a coil. Therefore,

an excitation coil would generate an alternating magnetic field that causes eddy

currents in the tested wire rope. Based on the excitation frequency used, eddy current

would induce a magnetic field itself. The resulting field of both the excitation field

Page 22: UNIVERSITI PUTRA MALAYSIA ANALYSIS OF HEAD LENGTH …psasir.upm.edu.my/id/eprint/5393/1/FK_2008_12.pdfuniversiti putra malaysia . analysis of head length effect of wire rope sensor

and the field caused by the eddy currents, induces a voltage in the measurement coils.

The pulse-echo ultrasonic techniques of a longitudinal ultrasonic wave applied from

one of the ends of the wire, propagating along it as a composite wave is one of the

recent techniques used in the wire rope inspection. However, studies were performed

looking for frequencies appropriated for giving good conditions to get good

sensitivity and transmission and low attenuation (Desimone, Katchadjian, Tacchia

and Giacchetta, 2001). Besides, ultrasonic testing requires sophisticated and high end

instrument for signal detection and processing.

Radiography is another method used in the wire rope inspection. However, it is very

hazardous and requires competent personnel for safety inspection. The radiographic

test method illustrates the volume density of a test body in a two dimensional image.

Gamma rays radiated by a radioactive isotope penetrate the cable and expose, in a

more or less attenuated form, an x-ray film placed on the other side of the cable.

Small wires fractures, corrosion and damage cannot normally be detected (Prakash,

1980).

In this research, a wire rope sensor based on electromagnetism principles has been

developed. This sensor is a passive type sensor and its structure is very simple. It is

made up of three main components; sensor head, center yoke rounded with copper

wire and a set of permanent magnet. The sensor would only produce a signal when

there is a flux change due to time that occurs between the sensor head and the wire

rope. Finite Element Method (FEM) simulations and theoretical calculations using

permeance method have been made to design the sensor and verify its efficiency. The

observations are followed by sets of experiment for the wire rope sensor with two

2

Page 23: UNIVERSITI PUTRA MALAYSIA ANALYSIS OF HEAD LENGTH …psasir.upm.edu.my/id/eprint/5393/1/FK_2008_12.pdfuniversiti putra malaysia . analysis of head length effect of wire rope sensor

different sizes of the head length where head length, Lh is defined as the length of the

sensor head. Generally, the main objective of the research is to study the effects of

designed parameter to the output voltage of the sensor. Specifically, the effects of the

head length, Lh to the output voltage of the sensor have been observed in this

research.

1.2 Problem Statement

Wire ropes are inspected periodically from the time they are installed until the time

they are replaced. The frequency of inspection depends on the character and

magnitude of the load carried by the rope and the condition of the rope. The closer to

the replacement time of the rope, the more frequently and accurately the inspection

has to be performed. The test procedure should be able to determine the actual

strength of the rope and whether or not the replacement criteria apply (Kalwa and

Piekarski, 1987).

Apart from careful visual examination and measurements of the external diameter,

the nondestructive test methods available utilize electromagnetic fields, X-rays or

mechanical waves (Wait, 1979). For example, in eddy current non destructive testing,

an exciting coil generates eddy currents in the metal, which is being tested. The eddy

currents are perturbed by defects in the metal, and the results is reflected in the

magnetic field above the metal surface. In order to detect perturbations in this field

one can observe changes in the impedance of the exciting coil or in the voltage

induced in a secondary coil, if separate coils are used for excitation and detection.

Unfortunately, in many important cases the changes are usually very small. Precise

3

Page 24: UNIVERSITI PUTRA MALAYSIA ANALYSIS OF HEAD LENGTH …psasir.upm.edu.my/id/eprint/5393/1/FK_2008_12.pdfuniversiti putra malaysia . analysis of head length effect of wire rope sensor

measurements of small variations in relatively large values of impedance are

difficult. Therefore, it requires additional detection devices such as differential eddy

current probes (Chady and Enokizono, 1999). Thus, this method is quiet complex and

inconvenience for field testing. The pulse-echo ultrasonic is one of the recent

techniques used in wire rope inspection. However, studies were performed looking

for frequencies appropriated for giving good conditions to get good sensitivity and

transmission and low attenuation (Desimone, Katchadjian, Tacchia and Giacchetta,

2001). Finally, the radiographic test method illustrates the volume density of a test

body in a two dimensional image (Prakash, 1980). However, it is very hazardous and

requires competent personnel for safety inspection.

In this research, an analysis on the constructed wire rope sensor based on

electromagnetism principles has been done (Shin, 2006). The advantages of this wire

rope sensor are it is a passive type sensor and its structure is very simple. Besides, its

highlighted features such as low cost, low power consumption and portable makes it

very convenient for wire inspection. However, it is necessary for the researcher to

design a wire rope sensor that will provide better performance.

In order to speed up the process of designing, an analysis based on magnetic circuit

analysis on the designed parameter of the wire rope sensor has been done. The

analysis is necessary to provide the researcher with a tool that manages to study the

physical structure behavior of the wire rope sensor. Derivation of theoretical equation

using permeance method was done based on the fabricated model by (Shin, 2006).

Then, it was analyzed using Finite Element Method (FEM) simulation and laboratory

experiment. Both methods were used to observe the effects of designed parameter of

4

Page 25: UNIVERSITI PUTRA MALAYSIA ANALYSIS OF HEAD LENGTH …psasir.upm.edu.my/id/eprint/5393/1/FK_2008_12.pdfuniversiti putra malaysia . analysis of head length effect of wire rope sensor

the wire rope sensor to the output voltage of the sensor. Specifically, the effects of

the head length, Lh of the sensor head to the output voltage of the sensor have been

chosen as the main designed parameter to be observed in this analysis.

1.3 Objectives

The aim of this study is to provide an analysis of head length effect of wire rope

sensor on output voltage using magnetic circuit analysis. There are two methods used

in the magnetic circuit analysis in this research; derivation of the theoretical equation

using permeance method and Finite Element Method (FEM) simulation. For

derivation of the theoretical equation derived using permeance method, analysis has

been done to the parameters involved in the equation to observe their effects to the

output voltage of the sensor and focused is made to study the effects of head length

of the sensor head to the output voltage. For FEM simulation, three effects of the

designed parameter have been observed; effects of air gap, effects of coil gap and the

back yoke saturation effects. Those effects have been studied to obtain the most

similar magnetic resistance in the wire rope and it is necessary to study the effects of

head length of the sensor head to the output voltage. Sets of laboratory experiment

are also being conducted to study the effects of head length of the sensor head to the

output voltage of the sensor. For conclusion, the major targets of this research can be

summarized as:

1. To derive the equation of the output voltage of the sensor using permeance

method and study the effects of designed parameter to the output voltage.

2. To perform the FEM simulation and study the effects of designed parameter

to the output voltage of the sensor.