unity pro v6 what is new
TRANSCRIPT
-
8/10/2019 Unity Pro V6 What is New
1/23
Unity Pro V6.0
Whats New
-
8/10/2019 Unity Pro V6 What is New
2/23
Content
Unity Pro V6.0 ID Quantum Evolutions M340 Evolutions Improve support of online changes Improved OFS tag management Improve services application Support of Third-party Applications
Schneider Electric 2- Division - Name Date
Integration of LL984 language
-
8/10/2019 Unity Pro V6 What is New
3/23
ID Card
Unity Pro V6.0 Sell Date June 30 th, 2011
New ref ending by CD60 XP 32bits VistaSeven 32bitsSeven 64bits
Package content
Supported OS Windows XP 32 bits Windows Vista 32 Bits Windows 7 32 and 64 bits Unity Pro can be run with USER Right
- Nevertheless Administration right ismandatory for installation and to UpdateDTM catalog.
Installation includes :
DVD Unity Pro: V6.0 X X XDTM EtherNet IP V1.0 X X X
DTM Psx RIO V1.0 X X X
Drivers: X X x
Modbus Serial V1.9 IE36 V2.1 IE11 V3.1 IE11
USB driver V1.5 IE20 V2.2 IE12 V3.2 IE12
UTW driver V1.10 IE22 V2.2 IE12 V3.2 IE12
XIP driver V1.11 IE24 V2.3 IE13 V3.3 IE13
PCIway driver V1.1 IE09 V2.1 IE11 V3.1 IE11
Schneider Electric 3- Division - Name Date
and Ethernet RIO- An update of the DTM catalog is neededbefore the first use.
Installation ofSchneider Electric Software Update- To receive automatic notification for
Unity Pro updates
USB-Fip Driver V1.0 IE06 V2.2 IE12 V3.3 IE13
SESU V1.1 X X X
CD Unity Loader V2.2 X X X
CD ACS V5.5 X X X
CD EIP Tool V1.1 X X X
DVD Documentation V6.0 X X X
Installed with Unity Pro installation
-
8/10/2019 Unity Pro V6 What is New
4/23
Quantum Evolutions
Quantum Ethernet RIO architectures Easy configuration of Ethernet RIO
architectures
Automatic configurationthrough DHCP server
Control of IP information(addresses compliance, gateways, subnetmask ...)
Integration of remote PRA configurations inmaster application managing the IO scanner PRA Integration in Unity Pro
Schneider Electric 4- Division - Name Date
Implementation in Unity Pro V6.0
E. Coudurier
Click HereFor Information
-
8/10/2019 Unity Pro V6 What is New
5/23
Quantum Evolutions
Respect of legacy platforms behavior for the migration.
Reset % M on start from STOP to RUN by configuring a project option
New module to extend communication distance between S908 drops
New fiber optic module repeater : 140 NRP 954 00
Schneider Electric 5- Division - Name Date
The 140 NRP 954 00 fiber optical repeater module provides communication between two or more RIO nodesor segments of networks over a fiber optic medium.
Each repeater contains one electrical RIO interface and two fiber optic transceivers. This module allows a peer to peer communication over a distance of 2 to 3 km and a maximum of thirty Km
using bus or self healing ring topology with a maximum of 12 repeaters.Unity Pro V6.0
-
8/10/2019 Unity Pro V6 What is New
6/23
M340 Evolutions
New High Speed Counting Module SSI interface module: BMX EAE 0300
Number of channels: 3 ransm ss on spee per c anne : z, z, z, z
Module cycle time per channel: 1 ms SSI Capture inputs: Two digital inputs IEC 61131-2 conformity: Type3 24VDC Absolute SSI encoder: 19.2 to 30 VDC Reflex outputs: One 24VDC push-pull per channel SSI encoder functions : Communication, Modulo, Capture, Compare
Transfer Program on SD card without Unity Pro
Schneider Electric 6- Division - Name Date
Send application and tool in a mail Write from any PC having a SD card reader
-
8/10/2019 Unity Pro V6 What is New
7/23
Improve SupportOf Online Changes
The following actions are allowed in RUN mode: Import / Export of DFB, DDT, EDT
Creating or removing variable without limitation Ability to prepare a modification online and activate it when needed
Schneider Electric 7- Division - Name Date
Indicator in the status bar to warn about compacting the memory
-
8/10/2019 Unity Pro V6 What is New
8/23
Improved OFSTag Management
Continuity of communication with OFS during online changes
Size reduction of data dictionary by exchanging only the necessary
Note: These two options need the use of OFS version 3.35
Schneider Electric 8- Division - Name Date
-
8/10/2019 Unity Pro V6 What is New
9/23
Operation and Maintenance:
Complete refoundation of Search/Replace Tool
ImproveApplication Services
rec access rom e menu ar
Find exact location of the required variable
Simplified cross-references window.
u oma c oo mar crea on or qu c access o eprevious searches
Schneider Electric 9- Division - Name Date
-
8/10/2019 Unity Pro V6 What is New
10/23
Operation and Maintenance:
Support unlocated data transfer after a complete application build
ImproveApplication Services
ew a a e orma ,
Animation tables with setting can be saved Set values can be saved with application,
exported and imported then applied
dtx
new e emen n s ruc ure an res ore a a e
Populates Force value from variables forcing state
Schneider Electric 10- Division - Name Date
-
8/10/2019 Unity Pro V6 What is New
11/23
Operation and Maintenance:
Update initial values from the controller to the local application
ImproveApplication Services
ar a e w n a va ue an save a r u ecan be updated with current value
Schneider Electric 11- Division - Name Date
Local application can then be simply updatedkeeping it unspoiled
-
8/10/2019 Unity Pro V6 What is New
12/23
-
8/10/2019 Unity Pro V6 What is New
13/23
ImproveApplication Services
Design:
Import of a section in the desired location
Symbolization of extracted bits for Device DDT and DTM structures
DROP_1.CRA_DIAGNOSTIC.0
Schneider Electric 13- Division - Name Date
Improved program readability through explicit default naming of FFB Before V6.0 V6.0
DROP_1.GLOBAL_IO_HEALTH
-
8/10/2019 Unity Pro V6 What is New
14/23
ImproveApplication Services
Design
New SATURATION function to control the precision of a real value
New HSBY_SWAP function to program primary / standby swap
Desired Precisiontested Value
Error when Value > Limit ValueLimit Value for desired Precision
Schneider Electric 14- Division - Name Date
Improved performances for BIT_TO_WORD, WORD_TO_BIT and SELfunctions Reduce execution time
- WORD_TO_BIT: 87%- BIT_TO_WORD: 72%
- SEL: 64%
40% cycle time reduction in applications usingmassively these instructions
-
8/10/2019 Unity Pro V6 What is New
15/23
ImproveApplication Services
Design
Locking and unlocking several DFB, selected from Data Properties window
Display the list of modified sectionswhen generating the application
Added protection of sectionfor subroutines (SR)
Schneider Electric 15- Division - Name Date
-
8/10/2019 Unity Pro V6 What is New
16/23
ImproveApplication Services
Ergonomics
In Ladder language activation of the mixed display mode is taken into
accoun or a sec ons
Schneider Electric 16- Division - Name Date
I
-
8/10/2019 Unity Pro V6 What is New
17/23
ImproveApplication Services
Ergonomics
Possibility to not prefix Advantys variables with the island name
Schneider Electric 17- Division - Name Date
When disabled, user is responsible for theuniqueness of the variables
I
-
8/10/2019 Unity Pro V6 What is New
18/23
ImproveApplication Services
General
New zipped export format ZEF includes DTM configuration e new z ppe expor orma nc u es e ev ce con gura on use n e rowser. a ows
the complete restitution of the project.Note: To be able to modify the configuration of DTM devices, needed DTMs must be installed on the PCwhere the application is imported.
Viewing application information in the tooltip and properties of STU file
Schneider Electric 18- Division - Name Date
S t Of Thi d t
-
8/10/2019 Unity Pro V6 What is New
19/23
Support Of Third-partyApplications
Better integration of third-party tools
Launch with context from Unity Pro s now poss e o aunc a r par y app ca on
giving the opened project as argument
Opening of section to a givenlocation row / column Third party application can now
open a section in a specific location
Additional information in export file CANopen topology and DTM topology Interface Descri tion for EF and EFB
Schneider Electric 19- Division - Name Date
I t g ti Of
-
8/10/2019 Unity Pro V6 What is New
20/23
Integration OfLL984 Language
Support of Modsoft, Concept, ProWorx NxT and ProWorx32 applications
Hardware configuration import
Customizable with partial import wizard
Execution on Quantum platforms Support of all Modbus data access function calls
Ensure LL984 execution behavior Network execution by column
Schneider Electric 20- Division - Name Date
Integration Of
-
8/10/2019 Unity Pro V6 What is New
21/23
Integration OfLL984 Language
Keep LL984 structure
Segments and networks State Flow and Power Flow animation
Equation networks available
Schneider Electric 21- Division - Name Date
Multiple network monitoring and
editing
Integration Of
-
8/10/2019 Unity Pro V6 What is New
22/23
Integration OfLL984 Language
Support of original LL984 functionalities with same look and feel
Symbols, descriptors, short and long comments
Max. 7 rows of documentation above eachreference in the LL984 instruction
Keep register information as documentation
Programming with mnemonics instructions
quickly
Button bar & Quick bar to access all LL984
Schneider Electric 22- Division - Name Date
-
8/10/2019 Unity Pro V6 What is New
23/23
Thank you
Schneider Electric 23- Division - Name Date