Page 1: UNITY Pro · PDF fileSchneider Electric 2 What is new in UNITY V7 Unity Pro V7.0 Configuration of new Ethernet IO architecture New Mx80 drops, NOC modules, Mix S908 and E IO architecture

Schneider Electric 1

UNITY Pro V7

What is new

Page 2: UNITY Pro · PDF fileSchneider Electric 2 What is new in UNITY V7 Unity Pro V7.0 Configuration of new Ethernet IO architecture New Mx80 drops, NOC modules, Mix S908 and E IO architecture

Schneider Electric 2

What is new in UNITY V7 Unity Pro V7.0

Configuration of new Ethernet IO architecture New Mx80 drops, NOC modules, Mix S908 and E IO architecture , Device DDT on M340 drops

Improved OnLine changes in RUN E IO Mx80 & Quantum drops modification, add E IO drops, analog forcing allowed in run.

Network Management Network manager allows easy routing of ethernet network

Easy FDT/DTM management Global DTM Services access, Cut & Paste, improved DTM catalog management....

New DTMs for improved productivity LL984 editor

LL984 library is now installed by default

Operation & Maintenance New powerfull Trending Tool, Animation table improvements, default Full screen mode, …

Design Structures with extracted bits

PLC catalog updates BMX ERT, BMX NRP …

XL Safety evolutions Support DFBs & arrays , new Modbus TCP DBB, new non interfering modules

System Time Stamping

Page 3: UNITY Pro · PDF fileSchneider Electric 2 What is new in UNITY V7 Unity Pro V7.0 Configuration of new Ethernet IO architecture New Mx80 drops, NOC modules, Mix S908 and E IO architecture

Schneider Electric 3

X X X SESU V1.1

X

X

X

V2.2 IE12

V2.1 IE11

V2.3 IE13

V2.3 IE13

V2.2 IE12

V2.2 IE12

X

X

X

X

Vista

Seven 32bits

X

X

X

V1.0 IE06

V1.1 IE09

V1.11 IE24

V1.11 IE23

V1.5 IE20

V1.10 IE37

X

X

X

X

XP 32bits

X

X

X

V3.3 IE13

V3.1 IE11

V3.3 IE13

V3.3 IE13

V3.2 IE12

V3.2 IE12

X

X

X

Seven 64bits

USB-Fip Driver

PCIway driver

XIP driver

USB driver

DTM Psx RIO V1.0

UTW driver

Modbus Serial

DTM EtherNet IP V1.0

Drivers:

DVD Documentation V7.0

CD Advantys CS V7.0

CD Unity Loader V 2.3

DVD Unity Pro: V7.0

Identity card of UNITY V7 Unity Pro V7.0

● Sell Date July 27th 2012

● New ref ending by CD70

● Supported OS

● Windows XP 32 bits

● Windows Vista 32 Bits

● Windows 7 32 and 64 bits

● Installation includes :

● Installation of DTMs for NOC

modules & Ethernet RIO

(automatic update of Catalog at first use)

● Installation of Schneider Electric

Software Update

To receive automatic notification for

Unity Pro updates

Installed with Unity Pro installation

Package content

X

Page 4: UNITY Pro · PDF fileSchneider Electric 2 What is new in UNITY V7 Unity Pro V7.0 Configuration of new Ethernet IO architecture New Mx80 drops, NOC modules, Mix S908 and E IO architecture

Schneider Electric 4

Easy configuration of new

Ethernet IOs new Mx80 drops (ex : M340)

Possibility to mix existing S908 RIO and Ethernet IO architecture

new Quantum NOC modules

Unity Pro V7.0

Page 5: UNITY Pro · PDF fileSchneider Electric 2 What is new in UNITY V7 Unity Pro V7.0 Configuration of new Ethernet IO architecture New Mx80 drops, NOC modules, Mix S908 and E IO architecture

Schneider Electric 5

Easy configuration of new

Ethernet IOs ●structured vision of datas thanks to Device DDT on M340 drops

Unity Pro V7.0

●Extend the advantages of implicit symbols thanks to easy modification

of implicit Device DDT name and Alias usage

implicit symbol names

MOD_ANA_2_1 OVEN_Zone1

Page 6: UNITY Pro · PDF fileSchneider Electric 2 What is new in UNITY V7 Unity Pro V7.0 Configuration of new Ethernet IO architecture New Mx80 drops, NOC modules, Mix S908 and E IO architecture

Schneider Electric 6

Ethernet IO evolution

Improved On Line changes in RUN Mx80 and Quantum Ethernet IO drop modification

Possibility to add Ethernet IO drops (Mx80 or Quantum)

Forcing of Analog IOs on M340 drops

Unity Pro V7.0

Page 7: UNITY Pro · PDF fileSchneider Electric 2 What is new in UNITY V7 Unity Pro V7.0 Configuration of new Ethernet IO architecture New Mx80 drops, NOC modules, Mix S908 and E IO architecture

Schneider Electric 7

Easy Network management

Powerfull Network Inspector allows easy routing of Ethernet networks,

by viewing and checking network configuration for ERIO network

(CRP312 and all ERIO drops), as well as 140NOC780 , 140NOC781 and

their childs

Unity Pro V7.0

view

Analyse

Configure in module

configuration screen

Page 8: UNITY Pro · PDF fileSchneider Electric 2 What is new in UNITY V7 Unity Pro V7.0 Configuration of new Ethernet IO architecture New Mx80 drops, NOC modules, Mix S908 and E IO architecture

Schneider Electric 8

Easy FDT DTM management Global DTM Services access

(for download, upload…)

and Copy & Paste

Allows easier and faster configuration of DTM architecture.

Unity Pro V7.0

Page 9: UNITY Pro · PDF fileSchneider Electric 2 What is new in UNITY V7 Unity Pro V7.0 Configuration of new Ethernet IO architecture New Mx80 drops, NOC modules, Mix S908 and E IO architecture

Schneider Electric 9

Easy FDT DTM management

●Direct access to catalog from

DTM Browser

●automatic update of Catalog

●Schneider Devices are

presented first

Unity Pro V7.0

●Display info on DTM creation

date, and device version

●Display info on uninstalled

DTMs

Page 10: UNITY Pro · PDF fileSchneider Electric 2 What is new in UNITY V7 Unity Pro V7.0 Configuration of new Ethernet IO architecture New Mx80 drops, NOC modules, Mix S908 and E IO architecture

Schneider Electric 10

Unity Pro V7.0

New DTM’s for improved productivity

New STB DTM’s available (use with 140NOCxx , BMXNOCxx & ETC101)

● User labels defined in

Advantys are imported in

Unity Pro (Device DDT

model)

Page 11: UNITY Pro · PDF fileSchneider Electric 2 What is new in UNITY V7 Unity Pro V7.0 Configuration of new Ethernet IO architecture New Mx80 drops, NOC modules, Mix S908 and E IO architecture

Schneider Electric 11

Unity Pro V7.0

New DTM’s for improved productivity

●New Altivar DTM’s (on CANopen, ModbusTCP, Modbus Serial)

●ATV312, 61, 71, ATS48

Page 12: UNITY Pro · PDF fileSchneider Electric 2 What is new in UNITY V7 Unity Pro V7.0 Configuration of new Ethernet IO architecture New Mx80 drops, NOC modules, Mix S908 and E IO architecture

Schneider Electric 12

Ladder Logic 984

LL984 editor

Since V6.1, the 6th powerfull programming langage, Ladder Logic 984

ensures full compatibility with Concept / ModSoft / ProWorks

and allows easy migration for all applications to M340 & Quantum

platforms.

LL984 library is now installed by default with Unity V7.0

Unity Pro V7.0

Page 13: UNITY Pro · PDF fileSchneider Electric 2 What is new in UNITY V7 Unity Pro V7.0 Configuration of new Ethernet IO architecture New Mx80 drops, NOC modules, Mix S908 and E IO architecture

Schneider Electric 13

● Powerfull Trending Tool allows easy monitoring of variables to

detect operating failures or improve performance of process.

Operation & maintenance Unity Pro V7.0

Select easily any relevant

variables in application

start acquisition…

save records on PC

Analyse records : compare to

Reference, use statistics

tools, copy to Excel…

For more details

Page 14: UNITY Pro · PDF fileSchneider Electric 2 What is new in UNITY V7 Unity Pro V7.0 Configuration of new Ethernet IO architecture New Mx80 drops, NOC modules, Mix S908 and E IO architecture

Schneider Electric 14

Since V6.0 user can :

• Update current values in the PLC with Set

values

• Reset all Set Values

• Save, import and export Animation tables

(with all Set values)

Operation & maintenance

In Animation table entering an address(%xxx) displays its name

Unity Pro V7.0

User can populate in one click “Set values” with current values in the PLC

In Unity V6.0 In Unity V7.0

So, Animation Tables can now easily be used as “recipes”

Page 15: UNITY Pro · PDF fileSchneider Electric 2 What is new in UNITY V7 Unity Pro V7.0 Configuration of new Ethernet IO architecture New Mx80 drops, NOC modules, Mix S908 and E IO architecture

Schneider Electric 15

Operation & maintenance

Information on last modification done

User name is displayed in title bar

Unity Pro V7.0

User name, PC name,

UNC application path and

.stu name are now

displayed in the PLC

screen online

Page 16: UNITY Pro · PDF fileSchneider Electric 2 What is new in UNITY V7 Unity Pro V7.0 Configuration of new Ethernet IO architecture New Mx80 drops, NOC modules, Mix S908 and E IO architecture

Schneider Electric 16

Operation & maintenance

Unity Pro can be started in Full Screen mode, with operator screen opened

●Rack Viewer improves customer diagnostic by displaying forced IOs and

S908 diagnostics

●Program Viewer allows LL984 program display …

Unity Pro V7.0

Page 17: UNITY Pro · PDF fileSchneider Electric 2 What is new in UNITY V7 Unity Pro V7.0 Configuration of new Ethernet IO architecture New Mx80 drops, NOC modules, Mix S908 and E IO architecture

Schneider Electric 17

Design

In Data Editor, user can create structures with extracted bits

Unity Pro V7.0

Machine1.Control.0 = Machine1.Start

Page 18: UNITY Pro · PDF fileSchneider Electric 2 What is new in UNITY V7 Unity Pro V7.0 Configuration of new Ethernet IO architecture New Mx80 drops, NOC modules, Mix S908 and E IO architecture

Schneider Electric 18

PLC catalog updates

● New M340 BMX NRP module

● New M340 BMX ERT module

● Existing M340 BMX NOM 0200 is usable on a EIO Mx80 drop (BMX

NOM0200.3) It features ModBus master & character mode, 2 max per drop

● New M340 BMXNOC401.2 and Premium TSXETC101.2 catalog entries and

related DTMs with improved services : NTP(Time synchro) and e-mail

● New Clock parameters for Quantum 140ERT85420

● Premium TSXP57 5xx and TSXP57 6xx support 1024 %MW (512 + 512)

max size of input/output data in the CANopen fast task (instead of 512

only)

Unity Pro V7.0

Page 19: UNITY Pro · PDF fileSchneider Electric 2 What is new in UNITY V7 Unity Pro V7.0 Configuration of new Ethernet IO architecture New Mx80 drops, NOC modules, Mix S908 and E IO architecture

Schneider Electric 19

UNITY V7 XL Safety evolutions

Support of DFBs and Arrays greatly improves productivity in the

development of Safety applications

Unity Pro V7.0 XLS

New non-interfering modules

New Modbus TCP SIL3 communication

DFBs

Page 20: UNITY Pro · PDF fileSchneider Electric 2 What is new in UNITY V7 Unity Pro V7.0 Configuration of new Ethernet IO architecture New Mx80 drops, NOC modules, Mix S908 and E IO architecture

Schneider Electric 20

In addition to Applicative mode…

a new System mode allows Time Stamp of variables from ERT (on local

or BMX ERIO CRA312 10 drop) and from discrete modules on BMX

ERIO CRA 312 10 drops

Time stamping Unity Pro V7.0

V70_HF1

for easy management via

OFS and VijeoCitect

(necessits OFS V3.4 & VijeoCitect

V7.30)