Editorial Comment Unintentional Endotrash! ‘‘It’’ Happens Victor Lucas, MD Section Head, Pediatric Cardiology, Ochsner Clinic Foundation, New Orleans, Louisiana Dr. Kuan-Ming Chiu reports an interesting case of an embolized self-expanding SVC stent managed ‘‘con- servatively’’ with a good long-term outcome. As back- ground, it can be sobering to simply Google ‘‘stent embolization and retrieval’’ and enjoy the plethora of interesting experiences reported. Happily, malposition and embolization of self-expanding stents have become less common problems with the newer nitinol stents and improved delivery systems but still can occur at the time of implant and later with stent migration. The most striking feature herein is that the embolized stent was left within the right atrium with no obvious adverse effects. Cardiologists with experience hand-mounting early generation balloon expandable stents soon realized the potential to relocate embolized stents to a relatively safe position (e.g., IVC, branch pulmonary arteries, iliac arteries) and expand the stent further to fix it in place. Even very large balloon expandable stents can be crushed and retrieved, albeit often requiring fairly large sheaths and even groin dissection to exteriorize the mangled stent. Self-expanding stents may be more well suited for the very dynamic, thin, and tortuous ve- nous vessels but can be difficult to impossible to remove percutaneously if malposition is encountered. A strategy to fix an embolized self-expanding stent in a safer location than within the heart still seems prudent. Imagination, patience, and a well-stocked inventory will be required. Starting with a deep breath and, if in the systemic circulation, more anticoagulation may be ad- visable as a careful plan is devised. Having more than one experienced operator is often quite helpful. As an example of the ingenuity required, Prischl et al. (1997) reported fixing a self expanding stent in the IVC above a chronic vena cava filter with a second vena cava filter. More ‘‘routinely,’’ passing a guidewire through the cen- ter of the stent into the target vessel (IVC, PA) allows introduction of a balloon catheter to help pass the stent to its final safer resting place. A small J-tip wire such as a Rosen wire can help avoid crossing the stent inter- stices. A stiffer wire can then be placed. A very compli- ant low pressure balloon can be helpful to allow balloon oversizing relative to the stent (without dilating the stent) to facilitate forward progress. A larger self- expanding stent can be placed within the first stent to help fix it in place more securely if needed. Interventional cardiologists and stent companies still await the development of the perfect stent. Recently, characteristics such as deliverability, radial strength, coverage, visibility, and drug delivery have improved dramatically. As stent development progresses, consid- eration of retrievability characteristics needs to be encouraged. Correspondence to: Victor Lucas, Section Head, Pediatric Cardiol- ogy, Ochsner Clinic Foundation, 1315 Jefferson Hwy., New Orleans, Louisiana. E-mail: [email protected] Received 26 September 2007; Revision accepted 26 September 2007 DOI 10.1002/ccd.21419 Published online 12 November 2007 in Wiley InterScience (www. interscience.wiley.com). ' 2007 Wiley-Liss, Inc. Catheterization and Cardiovascular Interventions 70:801 (2007)

Upload: victor-lucas

Post on 06-Jun-2016

232 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Unintentional endotrash! “it” happens

Editorial Comment

Unintentional Endotrash!‘‘It’’ Happens

Victor Lucas, MD

Section Head, Pediatric Cardiology,Ochsner Clinic Foundation,New Orleans, Louisiana

Dr. Kuan-Ming Chiu reports an interesting case ofan embolized self-expanding SVC stent managed ‘‘con-servatively’’ with a good long-term outcome. As back-ground, it can be sobering to simply Google ‘‘stentembolization and retrieval’’ and enjoy the plethora ofinteresting experiences reported. Happily, malpositionand embolization of self-expanding stents have becomeless common problems with the newer nitinol stentsand improved delivery systems but still can occur atthe time of implant and later with stent migration. Themost striking feature herein is that the embolized stentwas left within the right atrium with no obviousadverse effects.

Cardiologists with experience hand-mounting earlygeneration balloon expandable stents soon realized thepotential to relocate embolized stents to a relativelysafe position (e.g., IVC, branch pulmonary arteries,iliac arteries) and expand the stent further to fix it inplace. Even very large balloon expandable stents canbe crushed and retrieved, albeit often requiring fairlylarge sheaths and even groin dissection to exteriorizethe mangled stent. Self-expanding stents may be more

well suited for the very dynamic, thin, and tortuous ve-nous vessels but can be difficult to impossible toremove percutaneously if malposition is encountered.

A strategy to fix an embolized self-expanding stent ina safer location than within the heart still seems prudent.Imagination, patience, and a well-stocked inventory willbe required. Starting with a deep breath and, if in thesystemic circulation, more anticoagulation may be ad-visable as a careful plan is devised. Having more thanone experienced operator is often quite helpful. As anexample of the ingenuity required, Prischl et al. (1997)reported fixing a self expanding stent in the IVC abovea chronic vena cava filter with a second vena cava filter.More ‘‘routinely,’’ passing a guidewire through the cen-ter of the stent into the target vessel (IVC, PA) allowsintroduction of a balloon catheter to help pass the stentto its final safer resting place. A small J-tip wire such asa Rosen wire can help avoid crossing the stent inter-stices. A stiffer wire can then be placed. A very compli-ant low pressure balloon can be helpful to allow balloonoversizing relative to the stent (without dilating thestent) to facilitate forward progress. A larger self-expanding stent can be placed within the first stent tohelp fix it in place more securely if needed.

Interventional cardiologists and stent companies stillawait the development of the perfect stent. Recently,characteristics such as deliverability, radial strength,coverage, visibility, and drug delivery have improveddramatically. As stent development progresses, consid-eration of retrievability characteristics needs to beencouraged.

Correspondence to: Victor Lucas, Section Head, Pediatric Cardiol-

ogy, Ochsner Clinic Foundation, 1315 Jefferson Hwy., New Orleans,

Louisiana. E-mail: [email protected]

Received 26 September 2007; Revision accepted 26 September 2007

DOI 10.1002/ccd.21419

Published online 12 November 2007 in Wiley InterScience (www.

interscience.wiley.com).

' 2007 Wiley-Liss, Inc.

Catheterization and Cardiovascular Interventions 70:801 (2007)