Page 1: Unified Computing System Architecture- CLLE
Page 2: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

UCS System Architecture Overview Colin Sears

Page 3: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

Cisco Unified Computing System

3

SAN B Any ANSI T11 Compliant SAN

Mgmt

SAN A Any ANSI T11 Compliant SAN

LAN Any IEEE Compliant LAN

One Logical Chassis to Manage 160 Servers

LAN Connectivity

SAN Connectivity

Multiple Chassis

Blade & Rack Servers

Server Identity Management

Monitoring, Troubleshooting

Page 4: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

Cisco UCS Architecture

4

UCS Manager

XML API Standard APIs

APIs

Fabric Extenders

Compute

UCS Manager

Fabric Interconnects

Page 5: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

UCS Benefits

5

Highest Scale Unified Fabric

Virtual Adapters

Fabric Extenders

Fabric Interconnects

UCS C-series

UCS B-Series

Unified Management

Industry-leading compute without compromise

Unified Management

High Performance

Virtual Networks

Page 6: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

UCS Manager •  Embedded—manages entire UCS Domain

Fabric Interconnect •  10GE unified fabric switch

Chassis IO Module •  Remote line card

Blade Server Chassis •  Flexible bay configurations

Blade and Rack Servers •  x86 industry standard •  Patented extended memory

I/O Adapters •  Choice of multiple adapters

Building Blocks of Cisco UCS An Integrated System Optimizes Data Center Efficiency

6

Page 7: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

System Component Connectivity

7

Compute Chassis

x86 Computer x86 Computer

X

I I x8 x8 x8 x8

B

MGMT

S S

B

X X X X X

C C

A

G G

G G

SAN

G

R

A

G

G G

G

R

G

P M P

SAN LAN

Fabric Interconnect

Fabric Interconnect

Fabric Extender

Fabric Extender

Compute Blade (Half slot)

Adapter

Compute Blade (Full slot)

Adapter Adapter

§  Fabric Interconnect ‒ 32 Fixed Unified Ports + 4 or 1 Expansion slots to a maximum of 48 or 96 Unified Ports

§  Chassis ‒ Upto 8 half width blades or 4 full width blades

§  Fabric Extender ‒ Host to uplink traffic engineering ‒ Up to 160Gb Flexible bandwidth allocation

§  Adapter ‒ Virtualized adapter for single OS and hypervisor systems

§  Compute Blade

Page 8: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

UCS Fabric Interconnects 6100 6200

UCS Fabric Extenders Logically part of Fabric Interconnect Inserts into Blade Enclosure

UCS Blade Server Chassis Flexible bay configurations

UCS Blade Servers Different blade types Mix blade types within enclosure

UCS Rack Servers Different server types Standalone or UCSM integrated

Virtual Interface Cards Three adapter options Mix adapters within blade

UCS Manager Embedded in Fabric Interconnect

Building Blocks

8

Page 9: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

UCS 6248UP Fabric Interconnect

9

•  High Density 48 ports in 1RU •  1Tbps Switching capability •  All ports can be used as uplinks or

downlinks •  All ports can be configured to support either

1Gb or 10Gb speeds •  Unified Ports •  1 Expansion slots •  2us Latency •  80 PLUS Gold PSUs •  Backward and forward Compatibility

Feature details

Page 10: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

UCS 6296UP Fabric Interconnect

10

•  High Density 96 ports in 2RU •  2Tbps Switching capability •  All ports can be used as uplinks or

downlinks •  All ports can be configured to support either

1Gb or 10Gb speeds •  Unified Ports •  4 Expansion slots •  2us Latency •  80 PLUS Gold PSUs •  Backward and forward Compatibility

Feature details

Page 11: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

Unified Ports Dynamic Ports Allocation: Lossless Ethernet or Fibre Channel

11

Unified Port

Use-cases

Native Fibre Channel

§  Flexible LAN & storage convergence based on business needs

§  Service can be adjusted based on the demand for specific traffic

§  Convert protocol support on the same port dynamically

§  All ports on UCS 6200 Series §  16-port Expansion Module for

6248UP and 6296UP

Lossless Ethernet:

1/10GbE, FCoE, iSCSI, NAS

Benefits

§  Simplify switch purchase - remove ports ratio guess work

§  Increase design flexibility

§  Remove bandwidth bottlenecks

Page 12: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

UCS 6200 Expansion Module

12

UCS-FI-E16UP •  16 “Unified Ports” • Ports can be configured as either

Ethernet or Native FC Ports • Ethernet operations at 1/10 Gigabit

Ethernet •  Fibre Channel operations at 8/4/2/1G • Uses existing Ethernet SFP+ and

Cisco 8/4/2G and 4/2/1G FC Optics

Page 13: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

Unified Port Management

13

Page 14: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

UCS Fabric Interconnects 6100 6200

UCS Fabric Extenders Logically part of Fabric Interconnect Inserts into Blade Enclosure

UCS Blade Server Chassis Flexible bay configurations

UCS Blade Servers Different blade types Mix blade types within enclosure

UCS Rack Servers Different server types Standalone or UCSM integrated

Virtual Interface Cards Three adapter options Mix adapters within blade

UCS Manager Embedded in Fabric Interconnect

Building Blocks

14

Page 15: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

UCS 2204XP I/O Module

15

•  Increased uplink bandwidth •  4 x 10 Gig network-facing ports

•  Double the server-facing bandwidth •  16 x 10 Gig = 4 per half width slot

•  Two I/O Modules per chassis •  40Gbps to a single half-width blade

(20Gbps left and right) •  80Gbps to a full-width blade

•  Built in chassis management •  Fully managed by UCSM

Feature details

Page 16: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

UCS 2208XP I/O Module

16

•  Double the uplink bandwidth •  8 x 10 Gig network-facing ports

•  Quadruple the server-facing bandwidth •  32 x 10 Gig = 4 per half width slot

•  Two I/O Modules per chassis •  80Gbps to a single half-width blade

(40Gbps left and right) •  160Gbps to a full-width blade

•  Built in Chassis Management •  Fully Managed by UCSM

Feature details

Page 17: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

UCS Fabric Interconnects 6100 6200

UCS Fabric Extenders Logically part of Fabric Interconnect Inserts into Blade Enclosure

UCS Blade Server Chassis Flexible bay configurations

UCS Blade Servers Different blade types Mix blade types within enclosure

UCS Rack Servers Different server types Standalone or UCSM integrated

Virtual Interface Cards Three adapter options Mix adapters within blade

UCS Manager Embedded in Fabric Interconnect

Building Blocks

17

Page 18: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

UCS 5108 Blade Chassis

18

Chassis •  Up to 8 half slot blades •  Up to 4 full slot blades •  4x power supplies, N+N grid redundant •  8x fans included •  2x UCS 2104 Fabric Extender •  All items hot-pluggable

Page 19: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

4 to 8 Blades

4 Power Supplies

6U, 19” Rack

8 Fan Modules

4 Power Connectors

2 Fabric Extenders

UCS 5108 Blade Chassis Parts

19

Page 20: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

Redundant data and management paths

I/O Modules

Blade Connectors PSU Connectors

UCS 5108 Blade Chassis Backplane

20

Page 21: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

Wire for Bandwidth, Not Connectivity

•  Wire Once Architecture •  All links can be active all the time •  Policy-driven bandwidth allocation •  Virtual interface granularity

21

20G per Chassis 40G per Chassis 80G per Chassis 160G per Chassis

Page 22: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

High Availability in UCS

L1 to L1

L2 to L2

Mgmt Plane: active / standby Data Plane: active/active

Page 23: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

UCS Fabric Interconnects 6100 6200

UCS Fabric Extenders Logically part of Fabric Interconnect Inserts into Blade Enclosure

UCS Blade Server Chassis Flexible bay configurations

UCS Blade Servers Different blade types Mix blade types within enclosure

UCS Rack Servers Different server types Standalone or UCSM integrated

Virtual Interface Cards Three adapter options Mix adapters within blade

UCS Manager Embedded in Fabric Interconnect

Building Blocks

23

Page 24: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

Blade Overview

B22 M3 B200 M3 B250 M2 B420 M3 B230 M2 B440 M2

Slots 1 1 2 2 1 2

CPU E5-2400 E5-2600 Xeon 5600 E5-4600 E7-2800 E7-4800

Cores 16 16 12 32 20 40

DIMMs 12 24 48 48 32 32

Max GB 192GB 768GB 384GB 1.5TB 512GB 1TB

Disk 2 x 2.5” 2 x 2.5” 2 x 2.5” 4 x 2.5 2 SSD 4 x 2.5”

Raid 0/1 0/1 0/1 0/1/5/10 0/1 0/1/5/6

mLOM Dual 20Gb Dual 20Gb No Dual 20Gb No No

Mezz 1 1 2 2 1 2

24

Page 25: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

B22 M3 Blade

25

2 Socket Intel E5-2400

12 DIMM slots Maximum memory speed 1333MHz

2 Internal HDDs SFF - SAS, SATA and SSD options

LSI 2002 RAID Controller Supports RAID 0 and 1

1 Mezzanine card slot PCIe 3.0 x16 mezzanine connector

mLOM option

Page 26: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

B200 M3 Blade

26

2 Socket Intel E5 series CPUs

24 DIMM slots Maximum memory speed 1600MHz

2 Internal HDDs SFF - SAS, SATA and SSD options

LSI 2004 RAID Controller Supports RAID 0 and 1

1 Mezzanine card slot PCIe 3.0 x16 mezzanine connector

mLOM option

Page 27: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

B250 M2 Blade

27

2 Socket Intel 55xx and 56xx series CPUs

48 DIMM slots Maximum memory speed 1333MHz

2 Internal HDDs SFF - SAS, SATA and SSD options

LSI 1064 RAID Controller Supports RAID 0 and 1

2 Mezzanine card slot PCIe 2.0 x16 mezzanine connector

Page 28: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

B420 M3 Blade

28

4 Socket Intel E5-4600 CPUs

48 DIMM slots Maximum memory speed 1600MHz

4 Internal HDDs SFF - SAS, SATA and SSD options

LSI 2208R RAID Controller Supports RAID 0, 1, 5 and 10

2 Mezzanine card slot PCIe 3.0 x16 mezzanine connector

mLOM option

Page 29: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

B230 M2 Blade

29

2 Socket Intel E7 CPUs

32 DIMM slots Maximum memory speed 1066MHz

2 Internal HDDs 2.5 inch low profile SSD options

LSI 2108 RAID Controller Supports RAID 0 and 1

1 Mezzanine card slot PCIe 2.0 x16 mezzanine connector

Page 30: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

B440 M2 Blade

30

4 Socket Intel E7 CPUs

32 DIMM slots Maximum memory speed 1066MHz

4 Internal HDDs SFF – SAS, SATA and SSD options

LSI 2108 RAID Controller 1GB write cache Battery Backed cache option Supports RAID 0, 1, 5 and 6

2 Mezzanine card slot PCIe 2.0 x16 mezzanine connector

Page 31: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

B200 M2 and B250 M2 Blade Server CPU options

PID   CPU   Cores   QPI  Speed   Architecture  

Support  1333Mhz  Memory  Speed  

N20-­‐X00001   2.93GHz  Xeon  X5570  95W  CPU/8MB  cache/DDR3  1333MHz   4   6.4  GT/s   Nehalem-­‐EP    X  

N20-­‐X00002   2.53GHz  Xeon  E5540  80W  CPU/8MB  cache/DDR3  1066MHz   4   5.86  GT/s   Nehalem-­‐EP      

N20-­‐X00003   2.26GHz  Xeon  E5520  80W  CPU/8MB  cache/DDR3  1066MHz   4   5.86  GT/s   Nehalem-­‐EP      

N20-­‐X00004   2.26GHz  Xeon  L5520  60W  CPU/8MB  cache/DDR3  1066MHz   4   5.86  GT/s   Nehalem-­‐EP      

N20-­‐X00006   2.66GHz  Xeon  X5550  95W  CPU/8MB  cache/DDR3  1333MHz   4   6.4  GT/s   Nehalem-­‐EP    X  

N20-­‐X00009   2.00GHz  Xeon  E5504  80W  CPU/8MB  cache/DDR3  800MHz   4   4.8  GT/s   Nehalem-­‐EP      

A01-­‐X0100   3.33GHz  Xeon  X5680  130W  CPU/12MB  cache/DDR3  1333MHz   6   6.4  GT/s   Westmere-­‐EP    X  

A01-­‐X0102   2.93GHz  Xeon  X5670  95W  CPU/12MB  cache/DDR3  1333MHz   6   6.4  GT/s   Westmere-­‐EP    X  

A01-­‐X0105   2.66GHz  Xeon  X5650  95W  CPU/12MB  cache/DDR3  1333MHz   6   6.4  GT/s   Westmere-­‐EP    X  

A01-­‐X0106   2.26GHz  Xeon  L5640  60W  CPU/12MB  cache/DDR3  1333MHz         6   5.86  GT/s   Westmere-­‐EP    X  

A01-­‐X0107   2.13GHz  Xeon  L5630  40W  CPU/12MB  cache/DDR3  1066MHz   4   5.86  GT/s   Westmere-­‐EP      

A01-­‐X0108   1.86GHz  Xeon  L5609  40W  CPU/12MB  cache/DDR3  1066MHz   4   4.8  GT/s   Westmere-­‐EP      

A01-­‐X0109   2.66GHz  Xeon  E5640  80W  CPU/12MB  cache/DDR3  1066MHz   4   5.86  GT/s   Westmere-­‐EP      

A01-­‐X0111   2.40GHz  Xeon  E5620  80W  CPU/12MB  cache/DDR3  1066MHz   4   5.86  GT/s   Westmere-­‐EP      

A01-­‐X0113   2.13GHz  Xeon  E5506  80W  CPU/4MB  cache/DDR3  800MHz   4   4.8  GT/s   Nehalem-­‐EP      

A01-­‐X0115   3.46GHz  Xeon  X5690  130W  CPU/12MB  cache/DDR3  1333MHz   6   6.4  GT/s   Westmere-­‐EP   X  

A01-­‐X0117   3.06GHz  Xeon  X5675  95W  CPU/12MB  cache/DDR3  1333MHz   6   6.4  GT/s   Westmere-­‐EP   X  

A01-­‐X0120   2.53GHz  Xeon  E5649  80W  CPU/12MB  cache/DDR3  1333MHz   6   5.86  GT/s   Westmere-­‐EP   x  

A01-­‐X0123   2.13GHz  Xeon  E5606  80W  CPU/8MB  cache/DDR3  1066MHz   4   4.8  GT/s   Westmere-­‐EP  

31

Page 32: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

B200 M3 Blade Server CPU options

32

PID   CPU   Cores   QPI  Speed   Architecture  

Support  1600Mhz  Memory  Speed  

UCS-CPU-E5-2690   2.90 GHz E5-2690/135W 8C/20MB Cache/DDR3 1600MHz   8   8  GT/s   Xeon  E5    X  

UCS-CPU-E5-2680   2.70 GHz E5-2680 130W 8C/20MB Cache/DDR3 1600MHz   8   8  GT/s   Xeon  E5    x  

UCS-CPU-E5-2665   2.40 GHz E5-2665/115W 8C/20MB Cache/DDR3 1600MHz   8   8  GT/s   Xeon  E5   x    

UCS-CPU-E5-2650   2.00 GHz E5-2650/95W 8C/20MB Cache/DDR3 1600MHz   8   8  GT/s   Xeon  E5   x    

UCS-CPU-E5-2640   2.50 GHz E5-2640/95W 6C/15MB Cache/DDR3 1333MHz   6   7.2  GT/s   Xeon  E5      

UCS-CPU-E5-2620   2.00 GHz E5-2620/95W 6C/15MB Cache/DDR3 1333MHz   6   7.2  GT/s   Xeon  E5      

UCS-CPU-E5-2643   3.30 GHz E5-2643/130W 4C/10MB Cache/DDR3 1600MHz   4   8  GT/s   Xeon  E5    X  

UCS-CPU-E5-2660   2.20 GHz E5-2660/95W 8C/20MB Cache/DDR3 1600MHz   8   8  GT/s   Xeon  E5    X  

Page 33: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

B230 and B440 Blade Server CPU options

33

PID   CPU   Cores   QPI  Speed   Architecture   B230M1   B440M1   B230M2   B440M2  

A01-­‐X0308   2.00GHz  Xeon  X6550  130W  CPU/18MB  cache   8   6.4  GT/s   Nehalem-­‐EX  2S      

Yes   No   No   No  

A01-­‐X0304   2.00GHz  Xeon  E6540  105W  CPU/18MB  cache   6   6.4  GT/s   Nehalem-­‐EX  2S      

Yes   No   No   No  

A01-­‐X0302   1.73GHz  Xeon  E6510  105W  CPU/12MB  cache   4   4.8  GT/s   Nehalem-­‐EX  2S      

Yes   No   No   No  

A01-­‐X0200   2.26GHz  Xeon  X7560  130W  CPU/24MB  cache   8   6.4  GT/s   Nehalem-­‐EX      

Yes   Yes   No   No  

A01-­‐X0201   2.00GHz  Xeon  X7550  130W  CPU/18MB  cache   8   6.4  GT/s   Nehalem-­‐EX      

No   Yes   No   No  

A01-­‐X0206   1.86GHz  Xeon  L7555  95W  CPU/24MB  cache   8   5.8  GT/s   Nehalem-­‐EX      

Yes   Yes   No   No  

A01-­‐X0202   2.67GHz  Xeon  X7542  130W  CPU/18MB  cache   8   5.8  GT/s   Nehalem-­‐EX      

No   No   No   No  

A01-­‐X0203   2.00GHz  Xeon  E7540  105W  CPU/18MB  cache   6   6.4  GT/s   Nehalem-­‐EX      

No   Yes   No   No  

A01-­‐X0209   1.86GHz  Xeon  E7520  95W  CPU/18MB  cache   4   4.8  GT/s   Nehalem-­‐EX      

No   Yes   No   No  

UCS-­‐CPU-­‐E74870  2.4  GHz  E7-­‐4870  130W  10C  CPU  /  30M  Cache   10   6.4  GT/s   Westmere  EX  

   No   No   No   Yes  

UCS-­‐CPU-­‐E74860  2.26  GHZ  E7-­‐4860  130W  10C  CPU  /  24M  Cache   10   6.4  GT/s   Westmere  EX  

   No   No   No   Yes  

UCS-­‐CPU-­‐E74850  2  GHz  E7-­‐4850  130W  10C  CPU  /  24M  Cache   10   6.4  GT/s   Westmere  EX  

   No   No   No   Yes  

UCS-­‐CPU-­‐E74830  2.13  GHz  E7-­‐4830  105W  8C  CPU  /  24M  Cache   8   6.4  GT/s   Westmere  EX  

   No   No   No   Yes  

UCS-­‐CPU-­‐E74807  1.86  GHz  E7-­‐4807  95W  6c  CPU  /  18m  Cache   6   4.8  GT/s   Westmere  EX  

   No   No   No   Yes  

UCS-­‐CPU-­‐E72870   2.4  GHz  E7-­‐2870  130W  10C  /  30M  Cache   10   6.4  GT/s   Westmere  EX      

No   No   Yes   No  

UCS-­‐CPU-­‐E72860   2.26  GHz  E7-­‐2860  130W  10C  /  24M  Cache   10   6.4  GT/s   Westmere  EX      

No   No   Yes   No  

UCS-­‐CPU-­‐E72850   2  GHz  E7-­‐2850  130W  10C  /24M  Cache   10   6.4  GT/s   Westmere  EX      

No   No   Yes   No  

UCS-­‐CPU-­‐E72830   2.13  GHz  E7-­‐2830  105W  8C  /  24M  Cache   8   6.4  GT/s   Westmere  EX      

No   No   Yes   No  

UCS-­‐CPU-­‐E72803   1.73  GHz  E7-­‐2803  105W  6C  /  18M  Cache   6   4.8  GT/s   Westmere  EX      

No   No   Yes   No  

UCS-­‐CPU-­‐E78867L   2.13  GHz  E7-­‐8867L  105W  10C  /  30M  Cache   10   6.4  GT/s   Westmere  EX      

No   No   Yes   Yes  

Page 34: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

Drives Supported

34

B200 B250 B230 B440 146GB 6Gb SAS 15K X X X 300GB 6Gb SAS 15k X X X 300GB 6Gb SAS 10k X X X 600GB 6Gb SAS 10k X X X 900GB 6Gb SAS 10k X X X 500GB SATA 7.2k X 1TB SATA 7.2k X 100GB SATA SSD X X X 200GB SATA SSD X 100GB Low Height 7mm SATA SSD X 200GB Low Height 7mm SATA SSD X 300GB Low Height 7mm SATA SSD

X

Page 35: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

UCS Fabric Interconnects 6100 6200

UCS Fabric Extenders Logically part of Fabric Interconnect Inserts into Blade Enclosure

UCS Blade Server Chassis Flexible bay configurations

UCS Blade Servers Different blade types Mix blade types within enclosure

UCS Rack Servers Different server types Standalone or UCSM integrated

Virtual Interface Cards Three adapter options Mix adapters within blade

UCS Manager Embedded in Fabric Interconnect

Building Blocks

35

Page 36: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

Rack Mount Server Overview

C22 M3 C24 M3 C220 M3 C240 M3 C260 M2 C420 M3 C460 M2 RU 1 2 1 2 2 2 4

Cores 16 16 16 16 20 32 40

DIMMs 12 12 16 24 64 48 64

Max GB 192GB* 192GB* 512GB 768GB 1TB 1,5TB 512GB

Disk 8 x 2.5” or 4 x 3.5”

24 x 2.5” or 12 x 3.5”

8 x 2.5” or 4 x 3.5”

24 x 2.5” or 12 x 3.5”

16 x 2.5” or 32 x SSD 16 x 2.5” 16 x 2.5”

LoM 2 x 1Gb 2 x 1Gb 2 x 1Gb 4 x 1Gb 2 x 1Gb + 2 x 10Gb 2 x 10Gb 2 x 1Gb +

2 x 10Gb

PCIe Slots

2 x PCIe 3.0

5 x PCIe 3.0

2 x PCIe 3.0

5 x PCIe 3.0 6 x PCIe 2.0 6 x PCIe 3.0 10 x PCIe 2.0

Internal Storage USB Port USB Port USB Port

FlexFlash USB Port FlexFlash

USB Port FlexFlash

USB Port FlexFlash eUSB

*384GB w/ 32GB DIMMs 36

Page 37: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

CIMC

GE LOM PCIe Adapter

OS or Hypervisor

Nexus 2232

Mgmt Traffic

Data Traffic

Nexus 2232

UCS 6100 or 6200 UCS 6100 or 6200

• Reduce cost of deployment • Scale and performance • Choose from 5 servers • Scale to 160 C-Series per domain

UCS C-Series Integration to UCSM

37

Page 38: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

C200 M2 Rack Server

38

2 Socket Intel 55xx and 56xx CPUs

12 DIMM slots Maximum memory speed 1333MHz

4 3.5” or 8 2.5” Internal HDDs SFF – SAS, SATA and SSD options Battery Backed cache option

Built in Intel ICH10 SW Raid Supports RAID 0, 1, 5 and 10

650W PSUs 2 PCIe slots Height 1RU Integrated CIMC and KVM

Page 39: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

UCS C200 M2

39

PSUs VGA, Serial, USB and Management LAN

Internal LAN

DVD Power button, Status LEDs and KVM connector

Internal HDDs

Page 40: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

UCS C200 M2

40

Page 41: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

IOH!

Slot A!

Slot B !

X8!

X16!

½ Height!½ Length!

Full Height!½ Length!

SLOT A

SLOT B

UCS C200 M2

41

Page 42: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

C210 M2 Rack Server

42

2 Socket Intel 55xx and 56xx CPUs

12 DIMM slots Maximum memory speed 1333MHz

16 Internal HDDs SFF – SAS, SATA and SSD options Battery Backed cache option

Built in Intel ICH10 SW Raid Supports RAID 0, 1, 5 and 10

650W PSUs 5 PCIe slots Height 2RU Integrated CIMC and KVM

Page 43: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

UCS C210 M2

43

PSUs VGA, Serial, USB and Management LAN

Internal LAN

Page 44: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

UCS C210 M2

44

Page 45: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

UCS C210 M2

45

IOH!

PCIe Switch!

Slot A!

Slot B!

Slot C!

Slot D !

Slot E !

X8!

X8!

x8!

x8!

x8!

x8!

SLOT A

SLOT B

SLOT C

SLOT D

SLOT E

Full Height!½ Length!

Full Height!½ Length!

Full Height!½ Length!

Full Height!Full Length!

Full Height!Full Length!

Page 46: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

C220 M3 Rack Server

46

2 Socket Intel E5-2600

16 DIMM slots Maximum memory speed 1600MHz

8 or 4 Internal HDDs SFF and 3.5” – SAS, SATA and SSD options Battery Backed cache option

650W PSUs – Platinum Rated 2 PCIe slots Height 1RU Integrated CIMC and KVM

Page 47: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

C220 M3

47

PSUs VGA Serial and CIMC interfaces

Integrated 1Gb LOM Intel i350

USB

Page 48: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

C220 M3

48

Page 49: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

C220 M3

49

CPU!#1!

CPU!#2!

PCIe 3.0 x16 Slot A – Full height, ½ length

PCIe 3.0 x8 Slot B – ½ height, ½ length

PCIe 3.0 x8 RAID Mezz

SLOT A SLOT B

Page 50: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

C240 M3 Rack Server

50

2 Socket Intel E5-2600

24 DIMM slots Maximum memory speed 1600MHz

24 or 12 Internal HDDs SFF and 3.5” – SAS, SATA and SSD options Battery Backed cache option

650W and 1200W PSUs – Platinum Rated 5 PCIe slots – GPU ready Height 2RU Integrated CIMC and KVM

Page 51: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

C240 M3

51

PSUs VGA, Serial, USB and Management LAN Integrated 1Gb LOM

Intel i350

Page 52: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

C240 M3

52

Page 53: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

C240 M3

53

CPU!#1!

CPU!#2!

PCIe 3.0 x8 Slot C – Full height, ½ Length

PCIe 3.0 x8 Slot D – ½ height, ¾ length

PCIe 3.0 x8 RAID Mezz

PCIe 3.0 x8 Slot A – Full height, ½ Length

PCIe 3.0 x16 Slot B – Full height, ½ Length

PCIe 3.0 x16 Slot E – Full height, ¾ length, GPU ready

SLOT A

SLOT B

SLOT C

SLOT D SLOT E

Page 54: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

C250 M2 Rack Server

54

2 Socket Intel 55xx and 56xx CPUs

48 DIMM slots Maximum memory speed 1333MHz

8 Internal HDDs SFF – SAS, SATA and SSD options Battery Backed cache option

850W PSUs 5 PCIe slots Height 2RU Integrated CIMC and KVM

Page 55: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

UCS C250 M2

55

PSUs

Internal LAN VGA, Serial and USB Management ports

Hot Pluggable FANs

Page 56: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

UCS C250 M2

56

Page 57: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

UCS C250 M2

57

IOH!

PCIe Switch!

PCIe Switch!

Slot D!

Slot E!

Slot A!

Slot B !

Slot C !

x16!

x8!

x8!

x16!

x8!

x8!

x8!

Slot A

Slot E

Slot D Slot B

Slot C

Full Height!½ Length!

Full Height!½ Length!

½ Height!½ Length!

½ Height!½ Length!

½ Height!½ Length!

Page 58: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

C260 M2 Rack Server

58

2 Socket Intel E7 CPUs

32 or 64 DIMM slots Maximum memory speed 1066MHz

16 Internal HDDs SFF – SAS, SATA and SSD options Battery Backed cache option

1200W PSUs Internal Flash Storage 6 PCIe slots Height 2RU Integrated CIMC and KVM

Page 59: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

UCS C260 M2

59

Management ports Internal LAN Flex LOM

Page 60: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

UCS C260 M2

60

Page 61: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

UCS C260 M2

61

CPU!#1!

CPU!#2!

IOH!#1!

IOH!#2!

x16!

x8!

x8!

x8!

x8!

x4!

x16!

Raiser A

Raiser B

Slot A

Slot B

Slot C

Slot D

Flex LOM

½ Height!½ Length!

½ Height!½ Length!

½ Height!½ Length!½ Height!½ Length!

Full Height!½ Length!

Full Height!½ Length!

SLOT A

SLOT B

SLOT C

SLOT D

FLEX LOM

RAISER A RAISER B

Page 62: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

C460 M2 Rack Server

62

4 Socket Intel E7 CPUs

64 DIMM slots Maximum memory speed 1066MHz

12 Internal HDDs SFF – SAS, SATA and SSD options Battery Backed cache option

850W PSUs Internal Flash Storage 10 PCIe slots Height 4RU Integrated CIMC and KVM

Page 63: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

UCS C460 M2

63

Management ports

Internal LAN

Internal 10GbE LAN Base-T and SFP

Page 64: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

UCS C460 M2

64

Page 65: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

UCS C460 M2

65

IOH!#1!

Slot #9!½ length x8 physical !

Gen1 x4!

Gen2 x16 lanes!CPU!#3!

CPU!#1!

CPU!#2!

CPU!#4!

IOH!#2!

QPI Link

Slot #8!

Slot #6!

Slot #7!

Slot #5!

SAS Riser (occupied)!

Slot #1!

Slot #2!

Slot #3!

Slot #4!

Slot #10!½ length x8 physical!

Slot #1!

Slot #2!

Slot #3!

Slot #4!

Slot #8!¾ length x8 physical!

Slot #6 (Hot Swap)!¾ length x8 physical!

Slot #7 (Hot Swap)!¾ length x8 physical!

Slot #5!¾ length x16 physical!

Slot #1 (Hot Swap)!¾ length x8 physical!

Slot #2 (Hot Swap)!¾ length x8 physical!

Slot #3!½ length x8 physical!

Slot #4!½ length x8 physical!

ICH 10!(shared)! Gen1 x4!

Gen2 x8 lanes!

Gen2 x8 lanes!

Gen2 x4 lanes!

Gen1 x4 lanes!

Gen2 x8 lanes!

Gen2 x8 lanes!

Gen2 x8 lanes!

Gen2 x4 lanes!

Gen2 x4 lanes!

Page 66: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

UCS C460 M2

66

SA

S R

iser

Slo

t #1

Slo

t #2

Slo

t #3

Slo

t #4

Slo

t #5

Slo

t #6

Slo

t #7

Slo

t #8

Slo

t #9

Slo

t #1

0

Page 67: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

C200, C210 and C250 Rack Server CPU options

67

PID   CPU   Cores   QPI  Speed   Architecture  

Support  1333Mhz  Memory  Speed  

C200   C210   C250  

N20-­‐X00001   2.93GHz  Xeon  X5570  95W  CPU/8MB  cache/DDR3  1333MHz   4   6.4  GT/s   Nehalem-­‐EP    X   Yes   Yes   Yes  

N20-­‐X00002   2.53GHz  Xeon  E5540  80W  CPU/8MB  cache/DDR3  1066MHz   4   5.86  GT/s   Nehalem-­‐EP       Yes   Yes   Yes  

N20-­‐X00003   2.26GHz  Xeon  E5520  80W  CPU/8MB  cache/DDR3  1066MHz   4   5.86  GT/s   Nehalem-­‐EP       Yes   Yes   No  

N20-­‐X00004   2.26GHz  Xeon  L5520  60W  CPU/8MB  cache/DDR3  1066MHz   4   5.86  GT/s   Nehalem-­‐EP       Yes   Yes   No  

N20-­‐X00006   2.66GHz  Xeon  X5550  95W  CPU/8MB  cache/DDR3  1333MHz   4   6.4  GT/s   Nehalem-­‐EP    X   Yes   Yes   Yes  

N20-­‐X00009   2.00GHz  Xeon  E5504  80W  CPU/8MB  cache/DDR3  800MHz   4   4.8  GT/s   Nehalem-­‐EP       Yes   Yes   No  

A01-­‐X0100   3.33GHz  Xeon  X5680  130W  CPU/12MB  cache/DDR3  1333MHz   6   6.4  GT/s   Westmere-­‐EP    X   No   No   Yes  

A01-­‐X0102   2.93GHz  Xeon  X5670  95W  CPU/12MB  cache/DDR3  1333MHz   6   6.4  GT/s   Westmere-­‐EP    X   Yes   Yes   Yes  

A01-­‐X0105   2.66GHz  Xeon  X5650  95W  CPU/12MB  cache/DDR3  1333MHz   6   6.4  GT/s   Westmere-­‐EP    X   Yes   Yes   Yes  

A01-­‐X0106   2.26GHz  Xeon  L5640  60W  CPU/12MB  cache/DDR3  1333MHz         6   5.86  GT/s   Westmere-­‐EP   X   Yes   Yes   No  

A01-­‐X0107   2.13GHz  Xeon  L5630  40W  CPU/12MB  cache/DDR3  1066MHz   4   5.86  GT/s   Westmere-­‐EP       Yes   Yes   No  

A01-­‐X0108   1.86GHz  Xeon  L5609  40W  CPU/12MB  cache/DDR3  1066MHz   4   4.8  GT/s   Westmere-­‐EP       Yes   Yes   No  

A01-­‐X0109   2.66GHz  Xeon  E5640  80W  CPU/12MB  cache/DDR3  1066MHz   4   5.86  GT/s   Westmere-­‐EP       Yes   Yes   Yes  

A01-­‐X0111   2.40GHz  Xeon  E5620  80W  CPU/12MB  cache/DDR3  1066MHz   4   5.86  GT/s   Westmere-­‐EP       Yes   Yes   Yes  

A01-­‐X0113   2.13GHz  Xeon  E5506  80W  CPU/4MB  cache/DDR3  800MHz   4   4.8  GT/s   Nehalem-­‐EP       Yes   Yes   No  

A01-­‐X0115   3.46GHz  Xeon  X5690  130W  CPU/12MB  cache/DDR3  1333MHz   6   6.4  GT/s   Westmere-­‐EP   X   No   No   Yes  

A01-­‐X0117   3.06GHz  Xeon  X5675  95W  CPU/12MB  cache/DDR3  1333MHz   6   6.4  GT/s   Westmere-­‐EP   X   Yes   Yes   Yes  

A01-­‐X0120   2.53GHz  Xeon  E5649  80W  CPU/12MB  cache/DDR3  1333MHz   6   5.86  GT/s   Westmere-­‐EP   x   Yes   Yes   Yes  

A01-­‐X0123   2.13GHz  Xeon  E5606  80W  CPU/8MB  cache/DDR3  1066MHz   4   4.8  GT/s   Westmere-­‐EP   Yes   Yes   No  

Page 68: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

C220 and C240 Rack Server CPU Options

68

PID   CPU   Cores   QPI  Speed   Architecture  

Support  1600Mhz  Memory  Speed  

C220   C240  

UCS-CPU-E5-2690   2.90 GHz E5-2690/135W 8C/20MB Cache/DDR3 1600MHz   8   8  GT/s   Xeon  E5    X   Yes   Yes  

UCS-CPU-E5-2680   2.70 GHz E5-2680 130W 8C/20MB Cache/DDR3 1600MHz   8   8  GT/s   Xeon  E5    x   Yes   Yes  

UCS-CPU-E5-2665   2.40 GHz E5-2665/115W 8C/20MB Cache/DDR3 1600MHz   8   8  GT/s   Xeon  E5    x   Yes   Yes  

UCS-CPU-E5-2650   2.00 GHz E5-2650/95W 8C/20MB Cache/DDR3 1600MHz   8   8  GT/s   Xeon  E5    x   Yes   Yes  

UCS-CPU-E5-2640   2.50 GHz E5-2640/95W 6C/15MB Cache/DDR3 1333MHz   6   6.4  GT/s   Xeon  E5       Yes   Yes  

UCS-CPU-E5-2630   2.30 GHz E5-2630/95W 6C/15MB Cache/DDR3 1333MHz   6   4.8  GT/s   Xeon  E5       Yes   Yes  

UCS-CPU-E5-2620   2.00 GHz E5-2620/95W 6C/15MB Cache/DDR3 1333MHz   6   Xeon  E5   Yes   Yes  

UCS-CPU-E5-2609   2.4 GHz E5-2609/80W 4C/10MB Cache/DDR3 1066MHz   4   Xeon  E5   Yes   Yes  

UCS-CPU-E5-2643   3.30 GHz E5-2643/130W 4C/10MB Cache/DDR3 1600MHz   4   8  GT/s   Xeon  E5   X   Yes   Yes  

UCS-CPU-E5-2650L   1.8GHz E5-2650L/70W 8C/20MB Cache/DDR3 1600MHz   8   8  GT/s   Xeon  E5   X   Yes   Yes  

UCS-CPU-E5-2630L   2.00 GHz E5-2630L/60W 6C/15MB Cache/DDR3 1333MHz   6   Xeon  E5   Yes   Yes  

Page 69: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

C260 and C460 Rack Server CPU options

69

PID   CPU   Cores   QPI  Speed   Architecture   B440M1   C260M2   C460M2  

A01-­‐X0200   2.26GHz  Xeon  X7560  130W  CPU/24MB  cache   8   6.4  GT/s   Nehalem-­‐EX      

Yes   No   No  

A01-­‐X0201   2.00GHz  Xeon  X7550  130W  CPU/18MB  cache   8   6.4  GT/s   Nehalem-­‐EX      

Yes   No   No  

A01-­‐X0206   1.86GHz  Xeon  L7555  95W  CPU/24MB  cache   8   5.8  GT/s   Nehalem-­‐EX      

Yes   No   No  

A01-­‐X0202   2.67GHz  Xeon  X7542  130W  CPU/18MB  cache   8   5.8  GT/s   Nehalem-­‐EX      

Yes   No   No  

A01-­‐X0203   2.00GHz  Xeon  E7540  105W  CPU/18MB  cache   6   6.4  GT/s   Nehalem-­‐EX      

Yes   No   No  

A01-­‐X0209   1.86GHz  Xeon  E7520  95W  CPU/18MB  cache   4   4.8  GT/s   Nehalem-­‐EX      

Yes   No   No  

UCS-­‐CPU-­‐E74870  2.4  GHz  E7-­‐4870  130W  10C  CPU  /  30M  Cache   10   6.4  GT/s   Westmere  EX  

   No   No   Yes  

UCS-­‐CPU-­‐E74860  2.26  GHZ  E7-­‐4860  130W  10C  CPU  /  24M  Cache   10   6.4  GT/s   Westmere  EX  

   No   No   Yes  

UCS-­‐CPU-­‐E74850  2  GHz  E7-­‐4850  130W  10C  CPU  /  24M  Cache   10   6.4  GT/s   Westmere  EX  

   No   No   Yes  

UCS-­‐CPU-­‐E74830  2.13  GHz  E7-­‐4830  105W  8C  CPU  /  24M  Cache   8   6.4  GT/s   Westmere  EX  

   No   No   Yes  

UCS-­‐CPU-­‐E74807  1.86  GHz  E7-­‐4807  95W  6c  CPU  /  18m  Cache   6   4.8  GT/s   Westmere  EX  

   No   No   Yes  

UCS-­‐CPU-­‐E72870   2.4  GHz  E7-­‐2870  130W  10C  /  30M  Cache   10   6.4  GT/s   Westmere  EX      

No   Yes   No  

UCS-­‐CPU-­‐E72860   2.26  GHz  E7-­‐2860  130W  10C  /  24M  Cache   10   6.4  GT/s   Westmere  EX      

No   Yes   No  

UCS-­‐CPU-­‐E72850   2  GHz  E7-­‐2850  130W  10C  /24M  Cache   10   6.4  GT/s   Westmere  EX      

No   Yes   No  

UCS-­‐CPU-­‐E72830   2.13  GHz  E7-­‐2830  105W  8C  /  24M  Cache   8   6.4  GT/s   Westmere  EX      

No   Yes   No  

UCS-­‐CPU-­‐E72803   1.73  GHz  E7-­‐2803  105W  6C  /  18M  Cache   6   4.8  GT/s   Westmere  EX      

No   Yes   No  

UCS-­‐CPU-­‐E78867L   2.13  GHz  E7-­‐8867L  105W  10C  /  30M  Cache   10   6.4  GT/s   Westmere  EX      

No   Yes   Yes  

UCS-CPU-E78837   2.67  GHz  E7-­‐8837  130W  8C  /  30M  Cache   8   6.4  GT/s   Westmere  EX   No   No   Yes  

Page 70: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

Rack Mount RAID Controllers

70

Max # drives  SAS or SATA   RAID   BBC  C200   C210   C220 C240 C250   C260   C460  

ICH10   4   SATA   SW 0 and 1   x   x  LSI 1064   4   SAS/SATA   HW 0 and 1   x   x  LSI 3081E   8   SAS/SATA   HW 0 and 1   x  LSI 9240-8i   8   SAS/SATA   HW 0, 1, 5, 6, 10, 50 and 60   x  LSI 9260-8i   8   SAS/SATA   HW 0, 1, 5, 6, 10, 50 and 60   x   x   x  LSI 9261-8i   8   SAS/SATA   HW 0, 1, 5, 6, 10, 50 and 60   x   x   x   x  LSI 9280-4i4e   4   SAS/SATA   HW 0, 1, 5, 6, 10, 50 and 60   x   x  LSI 2008-8i 8   SAS/SATA   HW 0, 1, 5, 10 and 50   X   X  LSI 9266-8i 8   SAS/SATA   HW 0, 1, 5, 6, 10, 50 and 60   x   X   X  

Page 71: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

UCS Fabric Interconnects 6100 6200

UCS Fabric Extenders Logically part of Fabric Interconnect Inserts into Blade Enclosure

UCS Blade Server Chassis Flexible bay configurations

UCS Blade Servers Different blade types Mix blade types within enclosure

UCS Rack Servers Different server types Standalone or UCSM integrated

Virtual Interface Cards Three adapter options Mix adapters within blade

UCS Manager Embedded in Fabric Interconnect

Building Blocks

71

Page 72: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

UCS 1280 VIC

72

•  Dual 4x10 Gbps port-channel to a single slot •  Host connectivity PCIe Gen2 x6 •  HW Capable of 256 PCIe devices

•  OS restriction apply •  PCIe virtualization OS independent •  Single OS driver image for both VICs •  FabricFailover supported •  No user configuration required for 4x10Gb port

channel •  Not limited to 10Gig bandwidth per vNIC •  Flows from each vNIC can be load balanced

§  80 Gb I/O connectivity per adapter §  VM-FEX scale to 116 VM

Customer benefits

Feature details

Page 73: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

UCS 1240 VIC

73

•  Dual 2x10 Gbps port-channel to a single slot •  Host connectivity PCIe Gen2 x6 •  HW Capable of 256 PCIe devices

•  OS restriction apply •  PCIe virtualization OS independent •  Single OS driver image for both VICs •  FabricFailover supported •  No user configuration required for 2x10Gb port

channel •  Not limited to 10Gig bandwidth per vNIC •  Flows from each vNIC can be load balanced

§  40 Gb I/O connectivity per adapter §  VM-FEX scale to 116 VM

Customer benefits

Feature details

Page 74: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

UCS 1240 VIC with Port Expander

74

•  Dual 4x10 Gbps port-channel to a single slot •  Host connectivity PCIe Gen2 x6 •  HW Capable of 256 PCIe devices

•  OS restriction apply •  PCIe virtualization OS independent •  Single OS driver image for both VICs •  FabricFailover supported •  No user configuration required for 4x10Gb port

channel •  Not limited to 10Gig bandwidth per vNIC •  Flows from each vNIC can be load balanced

§  80 Gb I/O connectivity per server §  VM-FEX scale to 116 VM

Customer benefits

Feature details

Page 75: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

UCS 2104

UCS M81KR

IOH

CPU CPU

x16 Gen 1

x16 Gen 2

Mezz

Server Blade

Backplane

IO Modules UCS 2104

Fabric Interconnects

Blade Chassis

(UCS 6100)

(UCS 2104)

(M81KR)

UCS 2104

UCS M81KR

IOH

UCS 2104

UCS 5100 has 4 passive serial KR lanes to each half width server slot

5108 Chassis Backplane Connections Gen1

Page 76: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

`

IOM

IOM

B20

0 M

1/M

2 B

230

M1/

M2

x16 Gen1

All 4 KR lanes go to the single Mezz Slot

Mezz Slot (Only one available on M1/M2

Backplane lanes for M1/M2 Blades

Page 77: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

UCS B200 M3

Half width blade form factor

Modular LOM Slot

Connectors to the backplane

1.  mLOM Slot: Supports only the VIC 1240 2.  Mezz Slot: Supports VIC 1280 & 3rd party Gen 3 Mezz cards 3.  M81KR *NOT* supported on the M3 (Romley blades)

Mezzanine Slot

Page 78: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

`

IOM

Mezz Slot

IOM

B20

0M3

CPU # 1 CPU # 0

x16 Gen 2

QPI

x16 Gen 2

mLOM Slot

2 KR lanes go to the mLOM slot 2 KR lanes go to the Mezz Slot

Backplane lanes for B200 M3

Page 79: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

`

2104

-B

Mezz Slot Not Populated

2104

-A

B20

0M3

CPU # 1 CPU # 0

x16 Gen 2

QPI

x16 Gen 2

mLOM Slot VIC 1240

VIC 1240 has Dual 2x10 10Gb KR ports

BW to half width slot = Dual 10Gb

Only *valid* adapter option with IOM 2104

Sereno ASIC

Port 0 Port 1

2104 I/O Module with VIC 1240

Page 80: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

2208 I/O Module

80

2 1 3 4 6 5 7 8

6 5 7 8 22 21 23 24 30 29 31 32 14 13 15 16

•  8 Network Interface Ports •  32 Host Interface Ports

•  (4) 10G KR lanes per slot •  (2) 10G KR lanes to mLOM •  (2) 10G KR lanes to mezzanine adapter

Page 81: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

`

2208

-B

Mezz Slot Not Populated

2208

-A

B20

0M3

CPU # 1 CPU # 0

x16 Gen 2

QPI

x16 Gen 2

mLOM Slot VIC 1240

VIC 1240 has Dual 2x10 10Gb KR ports

BW to half width slot = Dual 2x10Gb

IOM 2208 has 4 KR lanes to each server slot

Sereno ASIC

Port 0 Port 1

2208 I/O Module with VIC 1240

Page 82: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

`

2208

-B

Mezz Slot Port Expander Card

For 1240

2208

-A

B20

0M3

CPU # 1 CPU # 0

x16 Gen 2

QPI

x16 Gen 2

mLOM Slot VIC 1240

Port Expander for VIC 1240 enables 2 additional ports of Sereno ASIC to each fabric

BW to half width slot = Dual 4x10Gb

Full BW of 2nd Gen VIC ASIC exposed

Sereno ASIC

Port 0 Port 1

2208 I/O Module with VIC 1240 & Port Expander

Page 83: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

`

2208

-B

Mezz Slot VIC 1280

2208

-A

B20

0M3

CPU # 1 CPU # 0

x16 Gen 2

QPI

x16 Gen 2

mLOM Slot VIC 1240

Unconnected ports of VIC 1280

BW to half width slot = Dual 2x10Gb + Dual 2x10Gb Each ASIC forms its own Ether channel

Adapter level “Redundancy” available with M3 (Romley) blades

VIC1280 is a PCIe device

Sereno ASIC

Port 0 Port 1 Sereno ASIC

Port 0 Port 1

2208 I/O Module with VIC 1240 and VIC 1280

Page 84: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

2204 I/O Module

84

2 1 3 4

6 5 7 8 2 1 3 4 14 13 15 16 10 9 11 12

•  4 Network Interface Ports •  16 Host Interface Ports

•  (2) 10G KR lanes per slot •  (1) 10G KR lane to mLOM •  (1) 10G KR lane to mezzanine adapter

Page 85: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

`

2204

-B

Mezz Slot Not Populated

2204

-A

B20

0M3

CPU # 1 CPU # 0

x16 Gen 2

QPI

x16 Gen 2

mLOM Slot VIC 1240

VIC 1240 has Dual 2x10 10Gb KR ports

BW to half width slot = Dual 10Gb

IOM 2204 has 2 KR lanes to each server slot

Most common Gen 2 I/O and M3 (Romley) combinatio

Sereno ASIC

Port 0 Port 1

2204 I/O Module with VIC 1240

Page 86: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

`

2204

-B

Mezz Slot Port Expander Card

For 1240

2204

-A

B20

0M3

CPU # 1 CPU # 0

x16 Gen 2

QPI

x16 Gen 2

mLOM Slot VIC 1240

Port Expander for VIC 1240 enables 2 additional ports of Sereno ASIC to each fabric but only one is connected to 2204

BW to half width slot = Dual 2x10Gb

Port Expander doubles the BW

Sereno ASIC

Port 0 Port 1

2204 I/O Module with VIC 1240 & Port Expander

Page 87: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

`

2204

-B

Mezz Slot VIC 1280

2204

-A

B20

0M3

CPU # 1 CPU # 0

x16 Gen 2

QPI

x16 Gen 2

mLOM Slot VIC 1240

Unconnected ports of VIC 1280

BW to half width slot = Dual 10Gb + Dual 10Gb Each ASIC is independent

Adapter level “Redundancy” available with lower BW

VIC1280 is a PCIe device

Sereno ASIC

Port 0 Port 1 Sereno ASIC

Port 0 Port 1

2204 I/O Module with VIC 1240 & VIC 1280

Page 88: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

UCS Fabric Interconnects 6100 6200

UCS Fabric Extenders Logically part of Fabric Interconnect Inserts into Blade Enclosure

UCS Blade Server Chassis Flexible bay configurations

UCS Blade Servers Different blade types Mix blade types within enclosure

UCS Rack Servers Different server types Standalone or UCSM integrated

Virtual Interface Cards Three adapter options Mix adapters within blade

UCS Manager Embedded in Fabric Interconnect

Building Blocks

88

Page 89: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

UCS Architectural Goals

89

§  Decouple admin overhead from number of managed endpoints

§  Deepest possible abstraction of hardware and connectivity

§  Reduce server provisioning time

§  Fully programmable platform

Page 90: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

•  Embedded device manager for family of UCS components •  Enables stateless computing via Service Profiles •  Efficient scale: Same effort for 1 to N blades •  APIs for integration with new and existing data center infrastructure

Unified Computing System Manager

90

Page 91: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

UCS Manager

91

UCS Manager

GUI Custom Portal or Tools

Systems Management Software

CLI

§  Single point of management for UCS system of components

‒ Adapters, blades, chassis, fabric extenders, fabric interconnects

§  Embedded device manager

‒ Discovery, Inventory, Configuration, Monitoring, Diagnostics, Statistics Collection

‒ Coordinated deployment to managed endpoints

§  APIs for integration with new and existing data center infrastructure

‒ SMASH-CLP, IPMI, SNMP

‒ XML-based SDK for commercial & custom implementations

Page 92: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

Decouple hardware config from hardware

Server Name UUID Boot Order

Boot Parameters WWN/WWPN MAC Address

SAN Attributes LAN Attributes

Page 93: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

Introducing Service Profiles

•  UCS Servers are somewhat similar to VMs •  Configuration files store server characteristics:

‒  Boot parameters

‒  NIC and HBA configuration (MAC, WWN, etc.)

‒  UUID

‒  Various policies (what happens when a link fails, etc.)

•  All those items can be grouped in pools •  Those service profiles are then mapped to

physical servers to very quickly provision one or more appropriate servers PHYSICAL SERVERS

Server Profiles

Server Name UUID MAC WWN Boot info LAN Config SAN Config

Page 94: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

Stateless Computing

•  Server identity no longer has to be tied to physical server hardware

Profiles provide identity

Seamless server mobility

Stateless blades

•  Boot over network (LAN or SAN) Boot order and boot devices are part of the

pre-defined logical server profile

On-board disks can be used for temp, swap, etc.

Server Name: LS-A UUID: 56 4d cd 3f 59 5b 61… MAC : 08:00:69:02:01:FC WWN: 5080020000075740 Boot Order: SAN, LAN

SAN LAN

Chassis-1/Blade-1

Chassis-9/Blade-5

Page 95: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

Pools •  UUID •  MAC •  WWNN / WWPN

Policies •  Boot Devices/Order •  Host F/W •  QoS •  Local Disk •  …

Templates •  VNIC •  VHBA

Templates •  Service Profile

Service Profile “Web-1”

Service Profile “Web-2”

Service Profile “Web-N” . .

.

Network •  VLANs •  VSANs •  Pin Groups

UCS Logical Building Blocks

95

• Connectivity

Page 96: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

How to create Service Profiles

Templated

Manual

Identity

(MAC Address, WWN, Etc.)

Behavior

(Firmware, QoS, Etc.)

Connectivity

(vNICs, vHBAs,)

Configuration Methods Service Profile Physical Blade

Cloned

Page 97: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

Concept of resource pools

blade pool policies

qualifications blade pools blades

P1

P3

C1S1

C1S1 C2S3

C3S4

C1S1

C4S8

adapters

memory

storage

adapters

CPU memory

P2

Page 98: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

More modularity: service profile policies

Ethernet Adapter Policy Tx- queues Rx – queues CoS

BIOS Policy Quiet boot Hyper-threading VT-technologies

Characteristics: • Consumed at instantiation of

Service Profile (SP) • Linked to specific

components of SP • Are usable through multiple

Organizations • Allow update of policy to

apply to those SPs that consume it

Page 99: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

Templates, policies and Service Profiles

Service Profile Template: Web Server

•  UUID: WebUUPool •  Boot Order: WebBootPolicy •  Host Firmware: WebFWPolicy •  SOL: SOLPolicy •  WWNN: WebWWNNPool

Adapter Policy: Eth0 VLAN: Web_FrontEnd Fabric: A MAC: WebMacPool-A

Adapter Policy: fc0 VSAN: Web-A Fabric: A WWPN: WebWWPNPool-A

Service Profile: Prod-Web-S1

Service Profile:Prod-Web-S12

• UUID: 10:02:03:04:05 • Boot Order: VM / SAN

Target 50:00:00:34:FA • Host Firmware: 9.0.03.146 • WWNN: 20:00:00:00:10 • WWPN: 20:00:00:00:20 • MAC: 20:03:CA:00:05

• UUID: 10:02:03:04:F3 • Boot Order: VM / SAN

Target 50:00:00:34:FA • Host Firmware: 9.0.03.146 • WWNN: 20:00:00:00:50 • WWPN: 20:00:00:00:40 • MAC: 20:03:CA:00:FA

Page 100: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public 100

Today: release 2.1 (“Del Mar”)

Page 101: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

UCS Centrale

101

UCS Manager UCS Manager

Data Center 1 UCS Manager UCS Manager

Data Center 2 UCS Manager

Data Center 3

Multi-UCS Manager

• Unifies management of multi UCS domains

•  Leverages UCS Manager technology • Simplify global operations with centralized

inventory, faults, logs, and server consoles

• Delivers global policies, service profiles, ID pools, and templates

•  Foundation for high availability, disaster recovery, and workload mobility

• Model based API for large scale automation

Page 102: Unified Computing System Architecture- CLLE

© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public

Register for Cisco Live - Orlando

Cisco Live - Orlando June 23 – 27, 2013 www.ciscolive.com/us

102 102