UCS System Architecture Overview Colin Sears
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
Cisco Unified Computing System
3
SAN B Any ANSI T11 Compliant SAN
Mgmt
SAN A Any ANSI T11 Compliant SAN
LAN Any IEEE Compliant LAN
One Logical Chassis to Manage 160 Servers
LAN Connectivity
SAN Connectivity
Multiple Chassis
Blade & Rack Servers
Server Identity Management
Monitoring, Troubleshooting
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
Cisco UCS Architecture
4
UCS Manager
XML API Standard APIs
APIs
Fabric Extenders
Compute
UCS Manager
Fabric Interconnects
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
UCS Benefits
5
Highest Scale Unified Fabric
Virtual Adapters
Fabric Extenders
Fabric Interconnects
UCS C-series
UCS B-Series
Unified Management
Industry-leading compute without compromise
Unified Management
High Performance
Virtual Networks
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
UCS Manager • Embedded—manages entire UCS Domain
Fabric Interconnect • 10GE unified fabric switch
Chassis IO Module • Remote line card
Blade Server Chassis • Flexible bay configurations
Blade and Rack Servers • x86 industry standard • Patented extended memory
I/O Adapters • Choice of multiple adapters
Building Blocks of Cisco UCS An Integrated System Optimizes Data Center Efficiency
6
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
System Component Connectivity
7
Compute Chassis
x86 Computer x86 Computer
X
I I x8 x8 x8 x8
B
MGMT
S S
B
X X X X X
C C
A
G G
G G
SAN
G
R
A
G
G G
G
R
G
P M P
SAN LAN
Fabric Interconnect
Fabric Interconnect
Fabric Extender
Fabric Extender
Compute Blade (Half slot)
Adapter
Compute Blade (Full slot)
Adapter Adapter
§ Fabric Interconnect ‒ 32 Fixed Unified Ports + 4 or 1 Expansion slots to a maximum of 48 or 96 Unified Ports
§ Chassis ‒ Upto 8 half width blades or 4 full width blades
§ Fabric Extender ‒ Host to uplink traffic engineering ‒ Up to 160Gb Flexible bandwidth allocation
§ Adapter ‒ Virtualized adapter for single OS and hypervisor systems
§ Compute Blade
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
UCS Fabric Interconnects 6100 6200
UCS Fabric Extenders Logically part of Fabric Interconnect Inserts into Blade Enclosure
UCS Blade Server Chassis Flexible bay configurations
UCS Blade Servers Different blade types Mix blade types within enclosure
UCS Rack Servers Different server types Standalone or UCSM integrated
Virtual Interface Cards Three adapter options Mix adapters within blade
UCS Manager Embedded in Fabric Interconnect
Building Blocks
8
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
UCS 6248UP Fabric Interconnect
9
• High Density 48 ports in 1RU • 1Tbps Switching capability • All ports can be used as uplinks or
downlinks • All ports can be configured to support either
1Gb or 10Gb speeds • Unified Ports • 1 Expansion slots • 2us Latency • 80 PLUS Gold PSUs • Backward and forward Compatibility
Feature details
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
UCS 6296UP Fabric Interconnect
10
• High Density 96 ports in 2RU • 2Tbps Switching capability • All ports can be used as uplinks or
downlinks • All ports can be configured to support either
1Gb or 10Gb speeds • Unified Ports • 4 Expansion slots • 2us Latency • 80 PLUS Gold PSUs • Backward and forward Compatibility
Feature details
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
Unified Ports Dynamic Ports Allocation: Lossless Ethernet or Fibre Channel
11
Unified Port
Use-cases
Native Fibre Channel
§ Flexible LAN & storage convergence based on business needs
§ Service can be adjusted based on the demand for specific traffic
§ Convert protocol support on the same port dynamically
§ All ports on UCS 6200 Series § 16-port Expansion Module for
6248UP and 6296UP
Lossless Ethernet:
1/10GbE, FCoE, iSCSI, NAS
Benefits
§ Simplify switch purchase - remove ports ratio guess work
§ Increase design flexibility
§ Remove bandwidth bottlenecks
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
UCS 6200 Expansion Module
12
UCS-FI-E16UP • 16 “Unified Ports” • Ports can be configured as either
Ethernet or Native FC Ports • Ethernet operations at 1/10 Gigabit
Ethernet • Fibre Channel operations at 8/4/2/1G • Uses existing Ethernet SFP+ and
Cisco 8/4/2G and 4/2/1G FC Optics
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
Unified Port Management
13
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
UCS Fabric Interconnects 6100 6200
UCS Fabric Extenders Logically part of Fabric Interconnect Inserts into Blade Enclosure
UCS Blade Server Chassis Flexible bay configurations
UCS Blade Servers Different blade types Mix blade types within enclosure
UCS Rack Servers Different server types Standalone or UCSM integrated
Virtual Interface Cards Three adapter options Mix adapters within blade
UCS Manager Embedded in Fabric Interconnect
Building Blocks
14
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
UCS 2204XP I/O Module
15
• Increased uplink bandwidth • 4 x 10 Gig network-facing ports
• Double the server-facing bandwidth • 16 x 10 Gig = 4 per half width slot
• Two I/O Modules per chassis • 40Gbps to a single half-width blade
(20Gbps left and right) • 80Gbps to a full-width blade
• Built in chassis management • Fully managed by UCSM
Feature details
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
UCS 2208XP I/O Module
16
• Double the uplink bandwidth • 8 x 10 Gig network-facing ports
• Quadruple the server-facing bandwidth • 32 x 10 Gig = 4 per half width slot
• Two I/O Modules per chassis • 80Gbps to a single half-width blade
(40Gbps left and right) • 160Gbps to a full-width blade
• Built in Chassis Management • Fully Managed by UCSM
Feature details
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
UCS Fabric Interconnects 6100 6200
UCS Fabric Extenders Logically part of Fabric Interconnect Inserts into Blade Enclosure
UCS Blade Server Chassis Flexible bay configurations
UCS Blade Servers Different blade types Mix blade types within enclosure
UCS Rack Servers Different server types Standalone or UCSM integrated
Virtual Interface Cards Three adapter options Mix adapters within blade
UCS Manager Embedded in Fabric Interconnect
Building Blocks
17
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
UCS 5108 Blade Chassis
18
Chassis • Up to 8 half slot blades • Up to 4 full slot blades • 4x power supplies, N+N grid redundant • 8x fans included • 2x UCS 2104 Fabric Extender • All items hot-pluggable
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
4 to 8 Blades
4 Power Supplies
6U, 19” Rack
8 Fan Modules
4 Power Connectors
2 Fabric Extenders
UCS 5108 Blade Chassis Parts
19
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
Redundant data and management paths
I/O Modules
Blade Connectors PSU Connectors
UCS 5108 Blade Chassis Backplane
20
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
Wire for Bandwidth, Not Connectivity
• Wire Once Architecture • All links can be active all the time • Policy-driven bandwidth allocation • Virtual interface granularity
21
20G per Chassis 40G per Chassis 80G per Chassis 160G per Chassis
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
High Availability in UCS
L1 to L1
L2 to L2
Mgmt Plane: active / standby Data Plane: active/active
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
UCS Fabric Interconnects 6100 6200
UCS Fabric Extenders Logically part of Fabric Interconnect Inserts into Blade Enclosure
UCS Blade Server Chassis Flexible bay configurations
UCS Blade Servers Different blade types Mix blade types within enclosure
UCS Rack Servers Different server types Standalone or UCSM integrated
Virtual Interface Cards Three adapter options Mix adapters within blade
UCS Manager Embedded in Fabric Interconnect
Building Blocks
23
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
Blade Overview
B22 M3 B200 M3 B250 M2 B420 M3 B230 M2 B440 M2
Slots 1 1 2 2 1 2
CPU E5-2400 E5-2600 Xeon 5600 E5-4600 E7-2800 E7-4800
Cores 16 16 12 32 20 40
DIMMs 12 24 48 48 32 32
Max GB 192GB 768GB 384GB 1.5TB 512GB 1TB
Disk 2 x 2.5” 2 x 2.5” 2 x 2.5” 4 x 2.5 2 SSD 4 x 2.5”
Raid 0/1 0/1 0/1 0/1/5/10 0/1 0/1/5/6
mLOM Dual 20Gb Dual 20Gb No Dual 20Gb No No
Mezz 1 1 2 2 1 2
24
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
B22 M3 Blade
25
2 Socket Intel E5-2400
12 DIMM slots Maximum memory speed 1333MHz
2 Internal HDDs SFF - SAS, SATA and SSD options
LSI 2002 RAID Controller Supports RAID 0 and 1
1 Mezzanine card slot PCIe 3.0 x16 mezzanine connector
mLOM option
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
B200 M3 Blade
26
2 Socket Intel E5 series CPUs
24 DIMM slots Maximum memory speed 1600MHz
2 Internal HDDs SFF - SAS, SATA and SSD options
LSI 2004 RAID Controller Supports RAID 0 and 1
1 Mezzanine card slot PCIe 3.0 x16 mezzanine connector
mLOM option
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
B250 M2 Blade
27
2 Socket Intel 55xx and 56xx series CPUs
48 DIMM slots Maximum memory speed 1333MHz
2 Internal HDDs SFF - SAS, SATA and SSD options
LSI 1064 RAID Controller Supports RAID 0 and 1
2 Mezzanine card slot PCIe 2.0 x16 mezzanine connector
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
B420 M3 Blade
28
4 Socket Intel E5-4600 CPUs
48 DIMM slots Maximum memory speed 1600MHz
4 Internal HDDs SFF - SAS, SATA and SSD options
LSI 2208R RAID Controller Supports RAID 0, 1, 5 and 10
2 Mezzanine card slot PCIe 3.0 x16 mezzanine connector
mLOM option
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
B230 M2 Blade
29
2 Socket Intel E7 CPUs
32 DIMM slots Maximum memory speed 1066MHz
2 Internal HDDs 2.5 inch low profile SSD options
LSI 2108 RAID Controller Supports RAID 0 and 1
1 Mezzanine card slot PCIe 2.0 x16 mezzanine connector
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
B440 M2 Blade
30
4 Socket Intel E7 CPUs
32 DIMM slots Maximum memory speed 1066MHz
4 Internal HDDs SFF – SAS, SATA and SSD options
LSI 2108 RAID Controller 1GB write cache Battery Backed cache option Supports RAID 0, 1, 5 and 6
2 Mezzanine card slot PCIe 2.0 x16 mezzanine connector
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
B200 M2 and B250 M2 Blade Server CPU options
PID CPU Cores QPI Speed Architecture
Support 1333Mhz Memory Speed
N20-‐X00001 2.93GHz Xeon X5570 95W CPU/8MB cache/DDR3 1333MHz 4 6.4 GT/s Nehalem-‐EP X
N20-‐X00002 2.53GHz Xeon E5540 80W CPU/8MB cache/DDR3 1066MHz 4 5.86 GT/s Nehalem-‐EP
N20-‐X00003 2.26GHz Xeon E5520 80W CPU/8MB cache/DDR3 1066MHz 4 5.86 GT/s Nehalem-‐EP
N20-‐X00004 2.26GHz Xeon L5520 60W CPU/8MB cache/DDR3 1066MHz 4 5.86 GT/s Nehalem-‐EP
N20-‐X00006 2.66GHz Xeon X5550 95W CPU/8MB cache/DDR3 1333MHz 4 6.4 GT/s Nehalem-‐EP X
N20-‐X00009 2.00GHz Xeon E5504 80W CPU/8MB cache/DDR3 800MHz 4 4.8 GT/s Nehalem-‐EP
A01-‐X0100 3.33GHz Xeon X5680 130W CPU/12MB cache/DDR3 1333MHz 6 6.4 GT/s Westmere-‐EP X
A01-‐X0102 2.93GHz Xeon X5670 95W CPU/12MB cache/DDR3 1333MHz 6 6.4 GT/s Westmere-‐EP X
A01-‐X0105 2.66GHz Xeon X5650 95W CPU/12MB cache/DDR3 1333MHz 6 6.4 GT/s Westmere-‐EP X
A01-‐X0106 2.26GHz Xeon L5640 60W CPU/12MB cache/DDR3 1333MHz 6 5.86 GT/s Westmere-‐EP X
A01-‐X0107 2.13GHz Xeon L5630 40W CPU/12MB cache/DDR3 1066MHz 4 5.86 GT/s Westmere-‐EP
A01-‐X0108 1.86GHz Xeon L5609 40W CPU/12MB cache/DDR3 1066MHz 4 4.8 GT/s Westmere-‐EP
A01-‐X0109 2.66GHz Xeon E5640 80W CPU/12MB cache/DDR3 1066MHz 4 5.86 GT/s Westmere-‐EP
A01-‐X0111 2.40GHz Xeon E5620 80W CPU/12MB cache/DDR3 1066MHz 4 5.86 GT/s Westmere-‐EP
A01-‐X0113 2.13GHz Xeon E5506 80W CPU/4MB cache/DDR3 800MHz 4 4.8 GT/s Nehalem-‐EP
A01-‐X0115 3.46GHz Xeon X5690 130W CPU/12MB cache/DDR3 1333MHz 6 6.4 GT/s Westmere-‐EP X
A01-‐X0117 3.06GHz Xeon X5675 95W CPU/12MB cache/DDR3 1333MHz 6 6.4 GT/s Westmere-‐EP X
A01-‐X0120 2.53GHz Xeon E5649 80W CPU/12MB cache/DDR3 1333MHz 6 5.86 GT/s Westmere-‐EP x
A01-‐X0123 2.13GHz Xeon E5606 80W CPU/8MB cache/DDR3 1066MHz 4 4.8 GT/s Westmere-‐EP
31
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
B200 M3 Blade Server CPU options
32
PID CPU Cores QPI Speed Architecture
Support 1600Mhz Memory Speed
UCS-CPU-E5-2690 2.90 GHz E5-2690/135W 8C/20MB Cache/DDR3 1600MHz 8 8 GT/s Xeon E5 X
UCS-CPU-E5-2680 2.70 GHz E5-2680 130W 8C/20MB Cache/DDR3 1600MHz 8 8 GT/s Xeon E5 x
UCS-CPU-E5-2665 2.40 GHz E5-2665/115W 8C/20MB Cache/DDR3 1600MHz 8 8 GT/s Xeon E5 x
UCS-CPU-E5-2650 2.00 GHz E5-2650/95W 8C/20MB Cache/DDR3 1600MHz 8 8 GT/s Xeon E5 x
UCS-CPU-E5-2640 2.50 GHz E5-2640/95W 6C/15MB Cache/DDR3 1333MHz 6 7.2 GT/s Xeon E5
UCS-CPU-E5-2620 2.00 GHz E5-2620/95W 6C/15MB Cache/DDR3 1333MHz 6 7.2 GT/s Xeon E5
UCS-CPU-E5-2643 3.30 GHz E5-2643/130W 4C/10MB Cache/DDR3 1600MHz 4 8 GT/s Xeon E5 X
UCS-CPU-E5-2660 2.20 GHz E5-2660/95W 8C/20MB Cache/DDR3 1600MHz 8 8 GT/s Xeon E5 X
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
B230 and B440 Blade Server CPU options
33
PID CPU Cores QPI Speed Architecture B230M1 B440M1 B230M2 B440M2
A01-‐X0308 2.00GHz Xeon X6550 130W CPU/18MB cache 8 6.4 GT/s Nehalem-‐EX 2S
Yes No No No
A01-‐X0304 2.00GHz Xeon E6540 105W CPU/18MB cache 6 6.4 GT/s Nehalem-‐EX 2S
Yes No No No
A01-‐X0302 1.73GHz Xeon E6510 105W CPU/12MB cache 4 4.8 GT/s Nehalem-‐EX 2S
Yes No No No
A01-‐X0200 2.26GHz Xeon X7560 130W CPU/24MB cache 8 6.4 GT/s Nehalem-‐EX
Yes Yes No No
A01-‐X0201 2.00GHz Xeon X7550 130W CPU/18MB cache 8 6.4 GT/s Nehalem-‐EX
No Yes No No
A01-‐X0206 1.86GHz Xeon L7555 95W CPU/24MB cache 8 5.8 GT/s Nehalem-‐EX
Yes Yes No No
A01-‐X0202 2.67GHz Xeon X7542 130W CPU/18MB cache 8 5.8 GT/s Nehalem-‐EX
No No No No
A01-‐X0203 2.00GHz Xeon E7540 105W CPU/18MB cache 6 6.4 GT/s Nehalem-‐EX
No Yes No No
A01-‐X0209 1.86GHz Xeon E7520 95W CPU/18MB cache 4 4.8 GT/s Nehalem-‐EX
No Yes No No
UCS-‐CPU-‐E74870 2.4 GHz E7-‐4870 130W 10C CPU / 30M Cache 10 6.4 GT/s Westmere EX
No No No Yes
UCS-‐CPU-‐E74860 2.26 GHZ E7-‐4860 130W 10C CPU / 24M Cache 10 6.4 GT/s Westmere EX
No No No Yes
UCS-‐CPU-‐E74850 2 GHz E7-‐4850 130W 10C CPU / 24M Cache 10 6.4 GT/s Westmere EX
No No No Yes
UCS-‐CPU-‐E74830 2.13 GHz E7-‐4830 105W 8C CPU / 24M Cache 8 6.4 GT/s Westmere EX
No No No Yes
UCS-‐CPU-‐E74807 1.86 GHz E7-‐4807 95W 6c CPU / 18m Cache 6 4.8 GT/s Westmere EX
No No No Yes
UCS-‐CPU-‐E72870 2.4 GHz E7-‐2870 130W 10C / 30M Cache 10 6.4 GT/s Westmere EX
No No Yes No
UCS-‐CPU-‐E72860 2.26 GHz E7-‐2860 130W 10C / 24M Cache 10 6.4 GT/s Westmere EX
No No Yes No
UCS-‐CPU-‐E72850 2 GHz E7-‐2850 130W 10C /24M Cache 10 6.4 GT/s Westmere EX
No No Yes No
UCS-‐CPU-‐E72830 2.13 GHz E7-‐2830 105W 8C / 24M Cache 8 6.4 GT/s Westmere EX
No No Yes No
UCS-‐CPU-‐E72803 1.73 GHz E7-‐2803 105W 6C / 18M Cache 6 4.8 GT/s Westmere EX
No No Yes No
UCS-‐CPU-‐E78867L 2.13 GHz E7-‐8867L 105W 10C / 30M Cache 10 6.4 GT/s Westmere EX
No No Yes Yes
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
Drives Supported
34
B200 B250 B230 B440 146GB 6Gb SAS 15K X X X 300GB 6Gb SAS 15k X X X 300GB 6Gb SAS 10k X X X 600GB 6Gb SAS 10k X X X 900GB 6Gb SAS 10k X X X 500GB SATA 7.2k X 1TB SATA 7.2k X 100GB SATA SSD X X X 200GB SATA SSD X 100GB Low Height 7mm SATA SSD X 200GB Low Height 7mm SATA SSD X 300GB Low Height 7mm SATA SSD
X
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
UCS Fabric Interconnects 6100 6200
UCS Fabric Extenders Logically part of Fabric Interconnect Inserts into Blade Enclosure
UCS Blade Server Chassis Flexible bay configurations
UCS Blade Servers Different blade types Mix blade types within enclosure
UCS Rack Servers Different server types Standalone or UCSM integrated
Virtual Interface Cards Three adapter options Mix adapters within blade
UCS Manager Embedded in Fabric Interconnect
Building Blocks
35
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
Rack Mount Server Overview
C22 M3 C24 M3 C220 M3 C240 M3 C260 M2 C420 M3 C460 M2 RU 1 2 1 2 2 2 4
Cores 16 16 16 16 20 32 40
DIMMs 12 12 16 24 64 48 64
Max GB 192GB* 192GB* 512GB 768GB 1TB 1,5TB 512GB
Disk 8 x 2.5” or 4 x 3.5”
24 x 2.5” or 12 x 3.5”
8 x 2.5” or 4 x 3.5”
24 x 2.5” or 12 x 3.5”
16 x 2.5” or 32 x SSD 16 x 2.5” 16 x 2.5”
LoM 2 x 1Gb 2 x 1Gb 2 x 1Gb 4 x 1Gb 2 x 1Gb + 2 x 10Gb 2 x 10Gb 2 x 1Gb +
2 x 10Gb
PCIe Slots
2 x PCIe 3.0
5 x PCIe 3.0
2 x PCIe 3.0
5 x PCIe 3.0 6 x PCIe 2.0 6 x PCIe 3.0 10 x PCIe 2.0
Internal Storage USB Port USB Port USB Port
FlexFlash USB Port FlexFlash
USB Port FlexFlash
USB Port FlexFlash eUSB
*384GB w/ 32GB DIMMs 36
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
CIMC
GE LOM PCIe Adapter
OS or Hypervisor
Nexus 2232
Mgmt Traffic
Data Traffic
Nexus 2232
UCS 6100 or 6200 UCS 6100 or 6200
• Reduce cost of deployment • Scale and performance • Choose from 5 servers • Scale to 160 C-Series per domain
UCS C-Series Integration to UCSM
37
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
C200 M2 Rack Server
38
2 Socket Intel 55xx and 56xx CPUs
12 DIMM slots Maximum memory speed 1333MHz
4 3.5” or 8 2.5” Internal HDDs SFF – SAS, SATA and SSD options Battery Backed cache option
Built in Intel ICH10 SW Raid Supports RAID 0, 1, 5 and 10
650W PSUs 2 PCIe slots Height 1RU Integrated CIMC and KVM
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
UCS C200 M2
39
PSUs VGA, Serial, USB and Management LAN
Internal LAN
DVD Power button, Status LEDs and KVM connector
Internal HDDs
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
UCS C200 M2
40
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
IOH!
Slot A!
Slot B !
X8!
X16!
½ Height!½ Length!
Full Height!½ Length!
SLOT A
SLOT B
UCS C200 M2
41
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
C210 M2 Rack Server
42
2 Socket Intel 55xx and 56xx CPUs
12 DIMM slots Maximum memory speed 1333MHz
16 Internal HDDs SFF – SAS, SATA and SSD options Battery Backed cache option
Built in Intel ICH10 SW Raid Supports RAID 0, 1, 5 and 10
650W PSUs 5 PCIe slots Height 2RU Integrated CIMC and KVM
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
UCS C210 M2
43
PSUs VGA, Serial, USB and Management LAN
Internal LAN
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
UCS C210 M2
44
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
UCS C210 M2
45
IOH!
PCIe Switch!
Slot A!
Slot B!
Slot C!
Slot D !
Slot E !
X8!
X8!
x8!
x8!
x8!
x8!
SLOT A
SLOT B
SLOT C
SLOT D
SLOT E
Full Height!½ Length!
Full Height!½ Length!
Full Height!½ Length!
Full Height!Full Length!
Full Height!Full Length!
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
C220 M3 Rack Server
46
2 Socket Intel E5-2600
16 DIMM slots Maximum memory speed 1600MHz
8 or 4 Internal HDDs SFF and 3.5” – SAS, SATA and SSD options Battery Backed cache option
650W PSUs – Platinum Rated 2 PCIe slots Height 1RU Integrated CIMC and KVM
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
C220 M3
47
PSUs VGA Serial and CIMC interfaces
Integrated 1Gb LOM Intel i350
USB
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
C220 M3
48
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
C220 M3
49
CPU!#1!
CPU!#2!
PCIe 3.0 x16 Slot A – Full height, ½ length
PCIe 3.0 x8 Slot B – ½ height, ½ length
PCIe 3.0 x8 RAID Mezz
SLOT A SLOT B
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
C240 M3 Rack Server
50
2 Socket Intel E5-2600
24 DIMM slots Maximum memory speed 1600MHz
24 or 12 Internal HDDs SFF and 3.5” – SAS, SATA and SSD options Battery Backed cache option
650W and 1200W PSUs – Platinum Rated 5 PCIe slots – GPU ready Height 2RU Integrated CIMC and KVM
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
C240 M3
51
PSUs VGA, Serial, USB and Management LAN Integrated 1Gb LOM
Intel i350
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
C240 M3
52
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
C240 M3
53
CPU!#1!
CPU!#2!
PCIe 3.0 x8 Slot C – Full height, ½ Length
PCIe 3.0 x8 Slot D – ½ height, ¾ length
PCIe 3.0 x8 RAID Mezz
PCIe 3.0 x8 Slot A – Full height, ½ Length
PCIe 3.0 x16 Slot B – Full height, ½ Length
PCIe 3.0 x16 Slot E – Full height, ¾ length, GPU ready
SLOT A
SLOT B
SLOT C
SLOT D SLOT E
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
C250 M2 Rack Server
54
2 Socket Intel 55xx and 56xx CPUs
48 DIMM slots Maximum memory speed 1333MHz
8 Internal HDDs SFF – SAS, SATA and SSD options Battery Backed cache option
850W PSUs 5 PCIe slots Height 2RU Integrated CIMC and KVM
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
UCS C250 M2
55
PSUs
Internal LAN VGA, Serial and USB Management ports
Hot Pluggable FANs
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
UCS C250 M2
56
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
UCS C250 M2
57
IOH!
PCIe Switch!
PCIe Switch!
Slot D!
Slot E!
Slot A!
Slot B !
Slot C !
x16!
x8!
x8!
x16!
x8!
x8!
x8!
Slot A
Slot E
Slot D Slot B
Slot C
Full Height!½ Length!
Full Height!½ Length!
½ Height!½ Length!
½ Height!½ Length!
½ Height!½ Length!
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
C260 M2 Rack Server
58
2 Socket Intel E7 CPUs
32 or 64 DIMM slots Maximum memory speed 1066MHz
16 Internal HDDs SFF – SAS, SATA and SSD options Battery Backed cache option
1200W PSUs Internal Flash Storage 6 PCIe slots Height 2RU Integrated CIMC and KVM
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
UCS C260 M2
59
Management ports Internal LAN Flex LOM
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
UCS C260 M2
60
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
UCS C260 M2
61
CPU!#1!
CPU!#2!
IOH!#1!
IOH!#2!
x16!
x8!
x8!
x8!
x8!
x4!
x16!
Raiser A
Raiser B
Slot A
Slot B
Slot C
Slot D
Flex LOM
½ Height!½ Length!
½ Height!½ Length!
½ Height!½ Length!½ Height!½ Length!
Full Height!½ Length!
Full Height!½ Length!
SLOT A
SLOT B
SLOT C
SLOT D
FLEX LOM
RAISER A RAISER B
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
C460 M2 Rack Server
62
4 Socket Intel E7 CPUs
64 DIMM slots Maximum memory speed 1066MHz
12 Internal HDDs SFF – SAS, SATA and SSD options Battery Backed cache option
850W PSUs Internal Flash Storage 10 PCIe slots Height 4RU Integrated CIMC and KVM
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
UCS C460 M2
63
Management ports
Internal LAN
Internal 10GbE LAN Base-T and SFP
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
UCS C460 M2
64
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
UCS C460 M2
65
IOH!#1!
Slot #9!½ length x8 physical !
Gen1 x4!
Gen2 x16 lanes!CPU!#3!
CPU!#1!
CPU!#2!
CPU!#4!
IOH!#2!
QPI Link
Slot #8!
Slot #6!
Slot #7!
Slot #5!
SAS Riser (occupied)!
Slot #1!
Slot #2!
Slot #3!
Slot #4!
Slot #10!½ length x8 physical!
Slot #1!
Slot #2!
Slot #3!
Slot #4!
Slot #8!¾ length x8 physical!
Slot #6 (Hot Swap)!¾ length x8 physical!
Slot #7 (Hot Swap)!¾ length x8 physical!
Slot #5!¾ length x16 physical!
Slot #1 (Hot Swap)!¾ length x8 physical!
Slot #2 (Hot Swap)!¾ length x8 physical!
Slot #3!½ length x8 physical!
Slot #4!½ length x8 physical!
ICH 10!(shared)! Gen1 x4!
Gen2 x8 lanes!
Gen2 x8 lanes!
Gen2 x4 lanes!
Gen1 x4 lanes!
Gen2 x8 lanes!
Gen2 x8 lanes!
Gen2 x8 lanes!
Gen2 x4 lanes!
Gen2 x4 lanes!
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
UCS C460 M2
66
SA
S R
iser
Slo
t #1
Slo
t #2
Slo
t #3
Slo
t #4
Slo
t #5
Slo
t #6
Slo
t #7
Slo
t #8
Slo
t #9
Slo
t #1
0
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
C200, C210 and C250 Rack Server CPU options
67
PID CPU Cores QPI Speed Architecture
Support 1333Mhz Memory Speed
C200 C210 C250
N20-‐X00001 2.93GHz Xeon X5570 95W CPU/8MB cache/DDR3 1333MHz 4 6.4 GT/s Nehalem-‐EP X Yes Yes Yes
N20-‐X00002 2.53GHz Xeon E5540 80W CPU/8MB cache/DDR3 1066MHz 4 5.86 GT/s Nehalem-‐EP Yes Yes Yes
N20-‐X00003 2.26GHz Xeon E5520 80W CPU/8MB cache/DDR3 1066MHz 4 5.86 GT/s Nehalem-‐EP Yes Yes No
N20-‐X00004 2.26GHz Xeon L5520 60W CPU/8MB cache/DDR3 1066MHz 4 5.86 GT/s Nehalem-‐EP Yes Yes No
N20-‐X00006 2.66GHz Xeon X5550 95W CPU/8MB cache/DDR3 1333MHz 4 6.4 GT/s Nehalem-‐EP X Yes Yes Yes
N20-‐X00009 2.00GHz Xeon E5504 80W CPU/8MB cache/DDR3 800MHz 4 4.8 GT/s Nehalem-‐EP Yes Yes No
A01-‐X0100 3.33GHz Xeon X5680 130W CPU/12MB cache/DDR3 1333MHz 6 6.4 GT/s Westmere-‐EP X No No Yes
A01-‐X0102 2.93GHz Xeon X5670 95W CPU/12MB cache/DDR3 1333MHz 6 6.4 GT/s Westmere-‐EP X Yes Yes Yes
A01-‐X0105 2.66GHz Xeon X5650 95W CPU/12MB cache/DDR3 1333MHz 6 6.4 GT/s Westmere-‐EP X Yes Yes Yes
A01-‐X0106 2.26GHz Xeon L5640 60W CPU/12MB cache/DDR3 1333MHz 6 5.86 GT/s Westmere-‐EP X Yes Yes No
A01-‐X0107 2.13GHz Xeon L5630 40W CPU/12MB cache/DDR3 1066MHz 4 5.86 GT/s Westmere-‐EP Yes Yes No
A01-‐X0108 1.86GHz Xeon L5609 40W CPU/12MB cache/DDR3 1066MHz 4 4.8 GT/s Westmere-‐EP Yes Yes No
A01-‐X0109 2.66GHz Xeon E5640 80W CPU/12MB cache/DDR3 1066MHz 4 5.86 GT/s Westmere-‐EP Yes Yes Yes
A01-‐X0111 2.40GHz Xeon E5620 80W CPU/12MB cache/DDR3 1066MHz 4 5.86 GT/s Westmere-‐EP Yes Yes Yes
A01-‐X0113 2.13GHz Xeon E5506 80W CPU/4MB cache/DDR3 800MHz 4 4.8 GT/s Nehalem-‐EP Yes Yes No
A01-‐X0115 3.46GHz Xeon X5690 130W CPU/12MB cache/DDR3 1333MHz 6 6.4 GT/s Westmere-‐EP X No No Yes
A01-‐X0117 3.06GHz Xeon X5675 95W CPU/12MB cache/DDR3 1333MHz 6 6.4 GT/s Westmere-‐EP X Yes Yes Yes
A01-‐X0120 2.53GHz Xeon E5649 80W CPU/12MB cache/DDR3 1333MHz 6 5.86 GT/s Westmere-‐EP x Yes Yes Yes
A01-‐X0123 2.13GHz Xeon E5606 80W CPU/8MB cache/DDR3 1066MHz 4 4.8 GT/s Westmere-‐EP Yes Yes No
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
C220 and C240 Rack Server CPU Options
68
PID CPU Cores QPI Speed Architecture
Support 1600Mhz Memory Speed
C220 C240
UCS-CPU-E5-2690 2.90 GHz E5-2690/135W 8C/20MB Cache/DDR3 1600MHz 8 8 GT/s Xeon E5 X Yes Yes
UCS-CPU-E5-2680 2.70 GHz E5-2680 130W 8C/20MB Cache/DDR3 1600MHz 8 8 GT/s Xeon E5 x Yes Yes
UCS-CPU-E5-2665 2.40 GHz E5-2665/115W 8C/20MB Cache/DDR3 1600MHz 8 8 GT/s Xeon E5 x Yes Yes
UCS-CPU-E5-2650 2.00 GHz E5-2650/95W 8C/20MB Cache/DDR3 1600MHz 8 8 GT/s Xeon E5 x Yes Yes
UCS-CPU-E5-2640 2.50 GHz E5-2640/95W 6C/15MB Cache/DDR3 1333MHz 6 6.4 GT/s Xeon E5 Yes Yes
UCS-CPU-E5-2630 2.30 GHz E5-2630/95W 6C/15MB Cache/DDR3 1333MHz 6 4.8 GT/s Xeon E5 Yes Yes
UCS-CPU-E5-2620 2.00 GHz E5-2620/95W 6C/15MB Cache/DDR3 1333MHz 6 Xeon E5 Yes Yes
UCS-CPU-E5-2609 2.4 GHz E5-2609/80W 4C/10MB Cache/DDR3 1066MHz 4 Xeon E5 Yes Yes
UCS-CPU-E5-2643 3.30 GHz E5-2643/130W 4C/10MB Cache/DDR3 1600MHz 4 8 GT/s Xeon E5 X Yes Yes
UCS-CPU-E5-2650L 1.8GHz E5-2650L/70W 8C/20MB Cache/DDR3 1600MHz 8 8 GT/s Xeon E5 X Yes Yes
UCS-CPU-E5-2630L 2.00 GHz E5-2630L/60W 6C/15MB Cache/DDR3 1333MHz 6 Xeon E5 Yes Yes
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
C260 and C460 Rack Server CPU options
69
PID CPU Cores QPI Speed Architecture B440M1 C260M2 C460M2
A01-‐X0200 2.26GHz Xeon X7560 130W CPU/24MB cache 8 6.4 GT/s Nehalem-‐EX
Yes No No
A01-‐X0201 2.00GHz Xeon X7550 130W CPU/18MB cache 8 6.4 GT/s Nehalem-‐EX
Yes No No
A01-‐X0206 1.86GHz Xeon L7555 95W CPU/24MB cache 8 5.8 GT/s Nehalem-‐EX
Yes No No
A01-‐X0202 2.67GHz Xeon X7542 130W CPU/18MB cache 8 5.8 GT/s Nehalem-‐EX
Yes No No
A01-‐X0203 2.00GHz Xeon E7540 105W CPU/18MB cache 6 6.4 GT/s Nehalem-‐EX
Yes No No
A01-‐X0209 1.86GHz Xeon E7520 95W CPU/18MB cache 4 4.8 GT/s Nehalem-‐EX
Yes No No
UCS-‐CPU-‐E74870 2.4 GHz E7-‐4870 130W 10C CPU / 30M Cache 10 6.4 GT/s Westmere EX
No No Yes
UCS-‐CPU-‐E74860 2.26 GHZ E7-‐4860 130W 10C CPU / 24M Cache 10 6.4 GT/s Westmere EX
No No Yes
UCS-‐CPU-‐E74850 2 GHz E7-‐4850 130W 10C CPU / 24M Cache 10 6.4 GT/s Westmere EX
No No Yes
UCS-‐CPU-‐E74830 2.13 GHz E7-‐4830 105W 8C CPU / 24M Cache 8 6.4 GT/s Westmere EX
No No Yes
UCS-‐CPU-‐E74807 1.86 GHz E7-‐4807 95W 6c CPU / 18m Cache 6 4.8 GT/s Westmere EX
No No Yes
UCS-‐CPU-‐E72870 2.4 GHz E7-‐2870 130W 10C / 30M Cache 10 6.4 GT/s Westmere EX
No Yes No
UCS-‐CPU-‐E72860 2.26 GHz E7-‐2860 130W 10C / 24M Cache 10 6.4 GT/s Westmere EX
No Yes No
UCS-‐CPU-‐E72850 2 GHz E7-‐2850 130W 10C /24M Cache 10 6.4 GT/s Westmere EX
No Yes No
UCS-‐CPU-‐E72830 2.13 GHz E7-‐2830 105W 8C / 24M Cache 8 6.4 GT/s Westmere EX
No Yes No
UCS-‐CPU-‐E72803 1.73 GHz E7-‐2803 105W 6C / 18M Cache 6 4.8 GT/s Westmere EX
No Yes No
UCS-‐CPU-‐E78867L 2.13 GHz E7-‐8867L 105W 10C / 30M Cache 10 6.4 GT/s Westmere EX
No Yes Yes
UCS-CPU-E78837 2.67 GHz E7-‐8837 130W 8C / 30M Cache 8 6.4 GT/s Westmere EX No No Yes
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
Rack Mount RAID Controllers
70
Max # drives SAS or SATA RAID BBC C200 C210 C220 C240 C250 C260 C460
ICH10 4 SATA SW 0 and 1 x x LSI 1064 4 SAS/SATA HW 0 and 1 x x LSI 3081E 8 SAS/SATA HW 0 and 1 x LSI 9240-8i 8 SAS/SATA HW 0, 1, 5, 6, 10, 50 and 60 x LSI 9260-8i 8 SAS/SATA HW 0, 1, 5, 6, 10, 50 and 60 x x x LSI 9261-8i 8 SAS/SATA HW 0, 1, 5, 6, 10, 50 and 60 x x x x LSI 9280-4i4e 4 SAS/SATA HW 0, 1, 5, 6, 10, 50 and 60 x x LSI 2008-8i 8 SAS/SATA HW 0, 1, 5, 10 and 50 X X LSI 9266-8i 8 SAS/SATA HW 0, 1, 5, 6, 10, 50 and 60 x X X
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
UCS Fabric Interconnects 6100 6200
UCS Fabric Extenders Logically part of Fabric Interconnect Inserts into Blade Enclosure
UCS Blade Server Chassis Flexible bay configurations
UCS Blade Servers Different blade types Mix blade types within enclosure
UCS Rack Servers Different server types Standalone or UCSM integrated
Virtual Interface Cards Three adapter options Mix adapters within blade
UCS Manager Embedded in Fabric Interconnect
Building Blocks
71
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
UCS 1280 VIC
72
• Dual 4x10 Gbps port-channel to a single slot • Host connectivity PCIe Gen2 x6 • HW Capable of 256 PCIe devices
• OS restriction apply • PCIe virtualization OS independent • Single OS driver image for both VICs • FabricFailover supported • No user configuration required for 4x10Gb port
channel • Not limited to 10Gig bandwidth per vNIC • Flows from each vNIC can be load balanced
§ 80 Gb I/O connectivity per adapter § VM-FEX scale to 116 VM
Customer benefits
Feature details
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
UCS 1240 VIC
73
• Dual 2x10 Gbps port-channel to a single slot • Host connectivity PCIe Gen2 x6 • HW Capable of 256 PCIe devices
• OS restriction apply • PCIe virtualization OS independent • Single OS driver image for both VICs • FabricFailover supported • No user configuration required for 2x10Gb port
channel • Not limited to 10Gig bandwidth per vNIC • Flows from each vNIC can be load balanced
§ 40 Gb I/O connectivity per adapter § VM-FEX scale to 116 VM
Customer benefits
Feature details
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
UCS 1240 VIC with Port Expander
74
• Dual 4x10 Gbps port-channel to a single slot • Host connectivity PCIe Gen2 x6 • HW Capable of 256 PCIe devices
• OS restriction apply • PCIe virtualization OS independent • Single OS driver image for both VICs • FabricFailover supported • No user configuration required for 4x10Gb port
channel • Not limited to 10Gig bandwidth per vNIC • Flows from each vNIC can be load balanced
§ 80 Gb I/O connectivity per server § VM-FEX scale to 116 VM
Customer benefits
Feature details
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
UCS 2104
UCS M81KR
IOH
CPU CPU
x16 Gen 1
x16 Gen 2
Mezz
Server Blade
Backplane
IO Modules UCS 2104
Fabric Interconnects
Blade Chassis
(UCS 6100)
(UCS 2104)
(M81KR)
UCS 2104
UCS M81KR
IOH
UCS 2104
UCS 5100 has 4 passive serial KR lanes to each half width server slot
5108 Chassis Backplane Connections Gen1
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
`
IOM
IOM
B20
0 M
1/M
2 B
230
M1/
M2
x16 Gen1
All 4 KR lanes go to the single Mezz Slot
Mezz Slot (Only one available on M1/M2
Backplane lanes for M1/M2 Blades
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
UCS B200 M3
Half width blade form factor
Modular LOM Slot
Connectors to the backplane
1. mLOM Slot: Supports only the VIC 1240 2. Mezz Slot: Supports VIC 1280 & 3rd party Gen 3 Mezz cards 3. M81KR *NOT* supported on the M3 (Romley blades)
Mezzanine Slot
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
`
IOM
Mezz Slot
IOM
B20
0M3
CPU # 1 CPU # 0
x16 Gen 2
QPI
x16 Gen 2
mLOM Slot
2 KR lanes go to the mLOM slot 2 KR lanes go to the Mezz Slot
Backplane lanes for B200 M3
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
`
2104
-B
Mezz Slot Not Populated
2104
-A
B20
0M3
CPU # 1 CPU # 0
x16 Gen 2
QPI
x16 Gen 2
mLOM Slot VIC 1240
VIC 1240 has Dual 2x10 10Gb KR ports
BW to half width slot = Dual 10Gb
Only *valid* adapter option with IOM 2104
Sereno ASIC
Port 0 Port 1
2104 I/O Module with VIC 1240
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
2208 I/O Module
80
2 1 3 4 6 5 7 8
6 5 7 8 22 21 23 24 30 29 31 32 14 13 15 16
• 8 Network Interface Ports • 32 Host Interface Ports
• (4) 10G KR lanes per slot • (2) 10G KR lanes to mLOM • (2) 10G KR lanes to mezzanine adapter
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
`
2208
-B
Mezz Slot Not Populated
2208
-A
B20
0M3
CPU # 1 CPU # 0
x16 Gen 2
QPI
x16 Gen 2
mLOM Slot VIC 1240
VIC 1240 has Dual 2x10 10Gb KR ports
BW to half width slot = Dual 2x10Gb
IOM 2208 has 4 KR lanes to each server slot
Sereno ASIC
Port 0 Port 1
2208 I/O Module with VIC 1240
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
`
2208
-B
Mezz Slot Port Expander Card
For 1240
2208
-A
B20
0M3
CPU # 1 CPU # 0
x16 Gen 2
QPI
x16 Gen 2
mLOM Slot VIC 1240
Port Expander for VIC 1240 enables 2 additional ports of Sereno ASIC to each fabric
BW to half width slot = Dual 4x10Gb
Full BW of 2nd Gen VIC ASIC exposed
Sereno ASIC
Port 0 Port 1
2208 I/O Module with VIC 1240 & Port Expander
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
`
2208
-B
Mezz Slot VIC 1280
2208
-A
B20
0M3
CPU # 1 CPU # 0
x16 Gen 2
QPI
x16 Gen 2
mLOM Slot VIC 1240
Unconnected ports of VIC 1280
BW to half width slot = Dual 2x10Gb + Dual 2x10Gb Each ASIC forms its own Ether channel
Adapter level “Redundancy” available with M3 (Romley) blades
VIC1280 is a PCIe device
Sereno ASIC
Port 0 Port 1 Sereno ASIC
Port 0 Port 1
2208 I/O Module with VIC 1240 and VIC 1280
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
2204 I/O Module
84
2 1 3 4
6 5 7 8 2 1 3 4 14 13 15 16 10 9 11 12
• 4 Network Interface Ports • 16 Host Interface Ports
• (2) 10G KR lanes per slot • (1) 10G KR lane to mLOM • (1) 10G KR lane to mezzanine adapter
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
`
2204
-B
Mezz Slot Not Populated
2204
-A
B20
0M3
CPU # 1 CPU # 0
x16 Gen 2
QPI
x16 Gen 2
mLOM Slot VIC 1240
VIC 1240 has Dual 2x10 10Gb KR ports
BW to half width slot = Dual 10Gb
IOM 2204 has 2 KR lanes to each server slot
Most common Gen 2 I/O and M3 (Romley) combinatio
Sereno ASIC
Port 0 Port 1
2204 I/O Module with VIC 1240
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
`
2204
-B
Mezz Slot Port Expander Card
For 1240
2204
-A
B20
0M3
CPU # 1 CPU # 0
x16 Gen 2
QPI
x16 Gen 2
mLOM Slot VIC 1240
Port Expander for VIC 1240 enables 2 additional ports of Sereno ASIC to each fabric but only one is connected to 2204
BW to half width slot = Dual 2x10Gb
Port Expander doubles the BW
Sereno ASIC
Port 0 Port 1
2204 I/O Module with VIC 1240 & Port Expander
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
`
2204
-B
Mezz Slot VIC 1280
2204
-A
B20
0M3
CPU # 1 CPU # 0
x16 Gen 2
QPI
x16 Gen 2
mLOM Slot VIC 1240
Unconnected ports of VIC 1280
BW to half width slot = Dual 10Gb + Dual 10Gb Each ASIC is independent
Adapter level “Redundancy” available with lower BW
VIC1280 is a PCIe device
Sereno ASIC
Port 0 Port 1 Sereno ASIC
Port 0 Port 1
2204 I/O Module with VIC 1240 & VIC 1280
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
UCS Fabric Interconnects 6100 6200
UCS Fabric Extenders Logically part of Fabric Interconnect Inserts into Blade Enclosure
UCS Blade Server Chassis Flexible bay configurations
UCS Blade Servers Different blade types Mix blade types within enclosure
UCS Rack Servers Different server types Standalone or UCSM integrated
Virtual Interface Cards Three adapter options Mix adapters within blade
UCS Manager Embedded in Fabric Interconnect
Building Blocks
88
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
UCS Architectural Goals
89
§ Decouple admin overhead from number of managed endpoints
§ Deepest possible abstraction of hardware and connectivity
§ Reduce server provisioning time
§ Fully programmable platform
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
• Embedded device manager for family of UCS components • Enables stateless computing via Service Profiles • Efficient scale: Same effort for 1 to N blades • APIs for integration with new and existing data center infrastructure
Unified Computing System Manager
90
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
UCS Manager
91
UCS Manager
GUI Custom Portal or Tools
Systems Management Software
CLI
§ Single point of management for UCS system of components
‒ Adapters, blades, chassis, fabric extenders, fabric interconnects
§ Embedded device manager
‒ Discovery, Inventory, Configuration, Monitoring, Diagnostics, Statistics Collection
‒ Coordinated deployment to managed endpoints
§ APIs for integration with new and existing data center infrastructure
‒ SMASH-CLP, IPMI, SNMP
‒ XML-based SDK for commercial & custom implementations
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
Decouple hardware config from hardware
Server Name UUID Boot Order
Boot Parameters WWN/WWPN MAC Address
SAN Attributes LAN Attributes
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
Introducing Service Profiles
• UCS Servers are somewhat similar to VMs • Configuration files store server characteristics:
‒ Boot parameters
‒ NIC and HBA configuration (MAC, WWN, etc.)
‒ UUID
‒ Various policies (what happens when a link fails, etc.)
• All those items can be grouped in pools • Those service profiles are then mapped to
physical servers to very quickly provision one or more appropriate servers PHYSICAL SERVERS
Server Profiles
Server Name UUID MAC WWN Boot info LAN Config SAN Config
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
Stateless Computing
• Server identity no longer has to be tied to physical server hardware
Profiles provide identity
Seamless server mobility
Stateless blades
• Boot over network (LAN or SAN) Boot order and boot devices are part of the
pre-defined logical server profile
On-board disks can be used for temp, swap, etc.
Server Name: LS-A UUID: 56 4d cd 3f 59 5b 61… MAC : 08:00:69:02:01:FC WWN: 5080020000075740 Boot Order: SAN, LAN
SAN LAN
Chassis-1/Blade-1
Chassis-9/Blade-5
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
Pools • UUID • MAC • WWNN / WWPN
Policies • Boot Devices/Order • Host F/W • QoS • Local Disk • …
Templates • VNIC • VHBA
Templates • Service Profile
Service Profile “Web-1”
Service Profile “Web-2”
Service Profile “Web-N” . .
.
Network • VLANs • VSANs • Pin Groups
UCS Logical Building Blocks
95
• Connectivity
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
How to create Service Profiles
Templated
Manual
Identity
(MAC Address, WWN, Etc.)
Behavior
(Firmware, QoS, Etc.)
Connectivity
(vNICs, vHBAs,)
Configuration Methods Service Profile Physical Blade
Cloned
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
Concept of resource pools
blade pool policies
qualifications blade pools blades
P1
P3
C1S1
C1S1 C2S3
C3S4
C1S1
C4S8
adapters
memory
storage
adapters
CPU memory
P2
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
More modularity: service profile policies
Ethernet Adapter Policy Tx- queues Rx – queues CoS
BIOS Policy Quiet boot Hyper-threading VT-technologies
Characteristics: • Consumed at instantiation of
Service Profile (SP) • Linked to specific
components of SP • Are usable through multiple
Organizations • Allow update of policy to
apply to those SPs that consume it
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
Templates, policies and Service Profiles
Service Profile Template: Web Server
• UUID: WebUUPool • Boot Order: WebBootPolicy • Host Firmware: WebFWPolicy • SOL: SOLPolicy • WWNN: WebWWNNPool
Adapter Policy: Eth0 VLAN: Web_FrontEnd Fabric: A MAC: WebMacPool-A
Adapter Policy: fc0 VSAN: Web-A Fabric: A WWPN: WebWWPNPool-A
Service Profile: Prod-Web-S1
Service Profile:Prod-Web-S12
• UUID: 10:02:03:04:05 • Boot Order: VM / SAN
Target 50:00:00:34:FA • Host Firmware: 9.0.03.146 • WWNN: 20:00:00:00:10 • WWPN: 20:00:00:00:20 • MAC: 20:03:CA:00:05
• UUID: 10:02:03:04:F3 • Boot Order: VM / SAN
Target 50:00:00:34:FA • Host Firmware: 9.0.03.146 • WWNN: 20:00:00:00:50 • WWPN: 20:00:00:00:40 • MAC: 20:03:CA:00:FA
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public 100
Today: release 2.1 (“Del Mar”)
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
UCS Centrale
101
UCS Manager UCS Manager
Data Center 1 UCS Manager UCS Manager
Data Center 2 UCS Manager
Data Center 3
Multi-UCS Manager
• Unifies management of multi UCS domains
• Leverages UCS Manager technology • Simplify global operations with centralized
inventory, faults, logs, and server consoles
• Delivers global policies, service profiles, ID pools, and templates
• Foundation for high availability, disaster recovery, and workload mobility
• Model based API for large scale automation
© 2013 Cisco and/or its affiliates. All rights reserved. BRKCOM-1005 Cisco Public
Register for Cisco Live - Orlando
Cisco Live - Orlando June 23 – 27, 2013 www.ciscolive.com/us
102 102