understanding doppler and its current uses in ob diana m. strickland, bsba, rdms, rdcs

56
Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS

Upload: cristopher-chafin

Post on 31-Mar-2015

221 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS

Understanding Doppler and its Current Uses in OB

Diana M. Strickland, BSBA, RDMS, RDCS

Page 2: Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS

Continuous vs. Pulsed

Page 3: Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS

Doppler – Moving structures-Red Blood Cells-

Scattered waves-low level NOISE!

Wall motion – high level NOISE!

ƒd = 2(ƒt • v • cosθ)/c

Page 4: Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS

Doppler – Moving structures-Red Blood Cells-

ft ft

fr fr

f

Time

Positive shift

Negative shift

Page 5: Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS

ft

f

time

Doppler – Moving structures-Red Blood Cells-

?

Page 6: Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS

ft

f

time

Page 7: Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS

ft

Doppler – Moving structures-Red Blood Cells-

<20o

Optimal

Page 8: Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS
Page 9: Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS

Doppler modes are differentiated by the way the signal is processed

Page 10: Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS

FFT – Fast Fourier Transform• Algorithm to display multiple frequencies in a single

time frame – Spectral Doppler• Think of a single note versus a chord• Color Doppler is an average of the spectral doppler

– it can’t show each frequency in a specific time unit• Standard display is BART – Blue away, Red towards

• Density of blood cells displayed as an intensity of gray • High density (power) – bright• Low density (power) – less bright

• Is power useful in Spectral Doppler – NO, but it is in Power Doppler• Color tone determined by density (#) of cells

Page 11: Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS

Plug Flow - Systole

Diastole

Consider spread through sample volume

Page 12: Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS

Broadening / Narrowing

Time

Frequency

S D

Envelope

Page 13: Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS
Page 14: Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS
Page 15: Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS
Page 16: Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS

Adjusting Parameters

• Gain• Scale• Baseline• Filter• Gate• Sweep

Page 17: Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS

Adjusting Parameters

• Gain• Scale• Baseline• Filter• Gate• Sweep

Page 18: Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS
Page 19: Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS
Page 20: Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS

Adjusting Parameters

• Gain• Scale• Baseline• Filter• Gate• Sweep

Page 21: Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS

Adjusting Parameters

• Gain• Scale• Baseline• Filter• Gate• Sweep

Page 22: Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS

Adjusting Parameters

• Gain• Scale• Baseline• Filter• Gate• Sweep

Page 23: Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS

Adjusting Parameters

• Gain• Scale• Baseline• Filter• Gate• Sweep

Page 24: Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS

Adjusting Parameters

• Gain• Scale• Baseline• Filter• Gate• Sweep

Page 25: Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS

Adjusting Parameters

• Gain• Scale• Baseline• Filter• Gate• Sweep

Page 26: Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS

Adjusting Parameters

•Gain

•Scale

•Baseline

•Filter

•Gate

•Sweep

Page 27: Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS

Size

Invert

Page 28: Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS

Other causes for poor Doppler signal…

• Frequency of transducer too high for vessel depth• Lower frequency

• Receiver gain too low• Increase gain

• Focal zone not optimized to area of interest – the vessel• Move it ;-)

Page 29: Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS

Fetal Well Being

• NST• BPP• Doppler

Page 30: Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS

Fetal Well Being

S / D

RI (Resistance Index or Pourcelot Index)(S-D)S

PI (Pulsatilty Index)(S-D)A

TAMV Time-averaged mean velocity

Maximum Systole / Minimum Diastole

Page 31: Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS
Page 32: Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS
Page 33: Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS
Page 34: Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS
Page 35: Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS

Middle Cerebral ArteryMCA

• Placental Insufficiency• Anemia (Isoimmunization / Parvo)

Page 36: Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS

MCA – Circle of Willus

ACA

ACo

MCA

PCoAPCA

BA IC

Page 37: Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS
Page 38: Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS

MCA – Placental Insufficiency• CerebroPlacental Ratio – CPR

• Originally used the anterior cerebral artery– Wladimiroff, et al.

• RI c / RI u• >1 Normal, <1 Redistribution

• MCA RI• <70 Indicative of Redistribution

• Others• Umb Artery RI• Umb Artery PI• MCA PI• MCA TAMV• Thoracic Aorta PI• Thoracic artery TAMV• UA/MCA PI ratio• MCA/Thoracic Aorta PI ratio• MCA PI x Thoracic TAMV

Page 39: Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS

MCA – Placental Insufficiency

• Valuable when fetus is reacting to hypoxia• When physiological responses to hypoxia

become exhausted, fetus cannot adapt further• Decline of forward cardiac function (increase

venous doppler indices)• Deregulation of cardiovascular homeostasis

may be seen and arterial circulation indices become less reliable.

Page 40: Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS

MCA – Placental InsufficiencyIncreased diastolic umbilical vein flow = GOOD

Increased diastolic cerebral flow - may signal placental problem

Page 41: Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS

Viscosity = # of red blood cells

Anemia

Page 42: Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS

Viscosity - Normal

Page 43: Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS

Viscosity - Anemia

Page 44: Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS
Page 45: Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS

MCA – Anemia• Fetuses healthy and w/ anemia mild, moderate,

and severe.• Linear models fitted to data for individual fetuses

– slope was determined• Average rate of change as a function of GA• MCA-PSV – expressed as MoM

• Healthy vs. Mild anemic – NS• Healthy vs. Severely anemic (P=.01)

• Conclusion – excellent tool to predict which fetuses will become severely anemic

Detti, Mari, Moise et al, AJOG Oct 2002

Page 46: Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS

MCA - Anemia

• Peak Velocity (w/fetal blood sampling)• Sensitivity for moderate or severe anemia 100%

FPR 12% fetuses w/o hydrops (Mari, et al, NEJM Jan 2000)• Fetuses w/Parvo B19 Sens /Spec 100/100% slightly less in

alloimmune group (included post transfusion follow-up) (Delle Chiaie, et al, USOG Sep 2001)

• Correlation between Hemoglobin and MCA-PSV becomes more accurate as severity of anemia increases. (Mari, et al, OG Apr 2002)

• TAMV (Abdel-Fattah, et al, BJR Sep 2002)

Page 47: Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS

IVC/SVC doppler

• Influenced by heart rate, RH hemodynamics and function, and AMOUNT of blood flowing through veins

• Reciprocal shift observed between IVC and SVC velocity waveforms (Smin)

• Changes another manifestation of blood flow redistribution toward the brain

• May be good to use prior to 30 weeks when doppler findings more difficult to interpret

Page 48: Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS
Page 49: Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS

Fetal Echo• Critical to evaluate flow an GV anomalies

• Quantitate flow – Artery size, volume, VTI• Direction of flow• Presence of flow• Quality of flow – turbulence• Tei Index – (TI) MV & LV flow in one

waveform• Tissue Doppler

MVLV

Page 50: Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS
Page 51: Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS
Page 52: Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS

Uterine Artery Doppler

• Continuous Wave Doppler / Intraplacental• IUGR (Chronic Hypertension) and

Preeclampsia• High AFP

• Little change seen in doppler indices after 26 weeks

• More difficult to assess when they are abnormal

Page 53: Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS
Page 54: Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS
Page 55: Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS

Ovarian Artery Doppler

• Tumor Angiogenesis – limited vascular tone due to absence of the muscular tunica media

• CD screening optimal in PM women• No cyclic change in ovarian volume

• RI < .40• 96.4% Sens., 98.8% Spec., 98.2 PPV in 14,317

patients• Kurjak, Fleischer, and Bourne

Page 56: Understanding Doppler and its Current Uses in OB Diana M. Strickland, BSBA, RDMS, RDCS

Ovarian Artery Doppler

• Impedance values in benign vs. malignant lesions overlap

• Studies now looking at arrangement and density of vessels

• Neural Networks and Baysian networks are being developed and tested