underground water service fittingsunderground water service fittings & couplings a.y. mcdonald...

24
A.Y. M c DONALD MFG. CO. WATER SERVICE PRODUCTS UNDERGROUND WATER SERVICE FITTINGS 4-07

Upload: others

Post on 20-Mar-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

A .Y. McDONALD MFG. CO.WATER SERVICE PRODUCTS

UNDERGROUND WATER SERVICE FITTINGS

4-07

Underground Water Service Fittings & Couplings

A.Y. McDONALD MFG. CO. • P.O. BOX 508 • DUBUQUE, IA 52004-0508 • tOLL FrEE 800-292-2737 • FAX [email protected] • www.aymcdonald.com2 4/07

*Also acceptable for use with 250# PSI polybutylene tubing.Insert stiffeners are required on all flexible plastic connections. See page 5.

EPDM gasket

tubing

AWWA straight threads

“T” nut

Stainless steel bev-eled gripper

recommended torque Chart for t Series Compression NutsTighten to the following minimum torques:

3/4" ............ 50 ft-lbs1" ............... 55 ft-lbs1 1/4" ......... 65 ft-lbs1 1/2" ......... 85 ft-lbs2" ............... 100 ft-lbs

AWWA straight threads

Flare nut

Copper Flare

Coppertubing

Bull nose endA. Remove the flare nut from the valve or fitting and slip it onto the copper tubing.

B. Flare the end of the copper tubing making sure the O.D. of the flare extends out to the threads in the flare nut, and is free of nicks and chips..

C. Screw the flare nut with tubing back onto the matching bull nose end of the valve or fitting and securely wrench tighten.

D. The flared portion of the copper tubing acts as a water-tight gasket and also is locked between the nut and coupling giving high pull-out resistance.

n T, and TA Compression

n 6130 Compression Coupling Converts Flare End to Compression AssemblyThe 6130 Compression Coupling converts any 3/4" or 1" flared joint into a tube size compression joint. For copper 6130CC or CTS polyethylene 6130CE.

A. Remove the flare nut from the valve or fitting and replace with the 6130 Coupling.B. Squarely cut the end of the copper or polyethylene tubing and insert it into the 6130 Coupling until the tubing bottoms out.*C. Tighten the 6130 Coupling onto the valve or fitting fingertight, then wrench tighten 2-3 more complete turns.DO NOt OVErtIGHtEN.

6130 body

AWWA straight threads

tubing

Stainless steel beveled gripper

EPDM gasket

Plastic spacerBull nose end

A. Insert tubing through the “T” compression nut and into the ma-chined socket of the valve or fitting.*B. Tighten the “T” compresion nut securely onto the valve or fitting, using the information from the recommended torque chart. This will: 1. Provide a water-tight seal by compressing both edges of the EPDM gasket around the tubing and; 2. Compress the stainless steel beveled gripper providing high pull-out resistance.NOtE: “T” Compression and Mac-Pak -22 nuts have the same threads and are interchangeable.

Copper tube, CtS PE (“t”) is stabbed thru nut to stab depth. the “t” nut is tightened to the required torque, which compresses the Buna-N or EPDM gasket and stainless steel beveled gripper, which creates a water-tight seal and pull-out strength.

“TA” Anode Compression Assembly

Copper tube is stabbed thru nut to stab depth. The “TA” nut is tightened to the required torque, which compresses the EPDM gasket and stainless steel beveled gripper, which cre-ates a water-tight seal and pull-out strength. A copper wire that leads to a zinc anode is locked into the compression nut via the stainless steel screw.

Stainless steel beveled gripper“T” nut

EPDM gasket

AWWA straight threads

Stab depth

tubing

Stainless steel screw

Anode nut

NOtE: Materials meet or exceed A.W.W.A. Standard C-800.

n Flare

For the electrical anode nut feature add “A” to the Model No.: 4701T = 4701tA

tubing

EPDM gasket AWWA straight threads

Stab depth

4700A

4700tA

Underground Water Service Fittings & Couplings

3A.Y. McDONALD MFG. CO. • P.O. BOX 508 • DUBUQUE, IA 52004-0508 • tOLL FrEE 800-292-2737 • FAX [email protected] • www.aymcdonald.com

4/07

*Also acceptable for use with 250# PSI polybutylene tubing.Insert stiffeners are required on all flexible plastic connections. See page 5.

n Mac-Pak Compression - 22, -33, -44, -55, -66, -67 and -68 Compression

AWWA straight threads

Mac-Pak nut with split clamp

Stainless steel screw

EPDM gasketAnti-friction ring

tubing

A. Insert tubing or plastic pipe through the nut into the machined socket in the valve or fitting.*

B. Wrench tighten the Mac-Pak nut securely onto the valve or fitting compressing the EPDM seal around the pipe or tubing, creating a water-tight seal.

C. Secure the split clamp onto the pipe or tubing by tightening the stainless steel bolt on the side of the clamp. Machined grooves in the split clamp provide additional gripping and electrical continuity.

D. Mac-Pak couplings are coded as follows: -22 SERIES - Tube size copper or P.E.* -- CtS -33 SERIES - Pipe size P.E.* PEP -44 SERIES - P.V.C. -- PVC -55 SERIES - Steel pipe -- IP

-66 SERIES - Strong lead pipe -- S -67 SERIES - Extra strong lead pipe -- XS -68 SERIES - Extra, extra strong lead pipe -- XXS

n McQuik Compression - Q, QA and -3Q Series

Q, QA or -3Q Series Nut

Stainless beveled gripper

EPDM gasket

Conductor Spring for electrical continuity

tubing

A. Stab tube* through the Q, QA or -3Q Series nut and into the socket of the valve or fitting until it bottoms out (three part unions may or may not have an internal stop).B. Tighten the McQuik Q, QA or -3Q Series nut to the stop. The end face of the nut is to contact the stop face of the body. This will: 1. Provide a water-tight seal by compressing both edges of the EPDM gasket around the tubing and; 2. Compress the stainless steel beveled gripper providing high pull-out resistance.

Copper tube CtS PE (Q), QA or PEP (-3Q) is stabbed through the nut to stab depth. the Q, QA or -3Q nut is tightened to the stop/shoulder on the body, which compresses the EPDM gasket and stainless steel beveled gripper, which creates a water-tight seal and pull-out strength. the electrical conductor spring makes positive contact between the copper tubing and the brass nut/fitting. When using with CtS PE (Q) QA or PEP (-3Q), the electrical conductor spring becomes purposeless.

Stainless steel beveled gripperQ, QA or

-3Q nutEPDM gasket

AWWA straight threads

Stab depth

tubing

Electrical conductor spring

Shoulder/stop

Copper tube or CtS PE (“-22”), PEP (“-33”), PVC (-44), IP (-55), strong lead (-66), extra strong lead (-67) or double extra strong lead (-68) is stabbed thru nut to stab depth. the nut is tightened to the required torque (see recommended torque chart for Mac-Pak compression), which compresses the EPDM gasket, which creates a water-tight seal. the stainless steel screw is tightened to the required torque (see chart), for pull-out strength.

Tighten to tthe following minimum torques:“-22”, “-33”, “-44”, “-55” CompressionFor nut: 1/2" ......... 20 ft-lbs 1" .............. 30 ft-lbs 1 1/2" ......... 40 ft-lbs(ft-lbs) 3/4" ......... 25 ft-lbs 1 1/4" ........ 35 ft-lbs 2" ............... 45 ft-lbs

For clamp 1/2" ... 70-80 in-lbs 1" ...... 90-100 in-lbs 1 1/2" 160-180 in-lbsside screw: 3/4" ... 80-90 in-lbs 1 1/4" 120-140 in-lbs 2" ..... 200-220 in-lbs(in-lbs)

Lead Mac-Pak Comp. “-66”, “-67”, “-68” CompressionFor nut: 1/2" ......... 25 ft-lbs 1" .............. 40 ft-lbs 1 1/2" ......... 50 ft-lbs(ft-lbs) 5/8" ......... 30 ft-lbs 1 1/4" ........ 45 ft-lbs 2" ............... 55 ft-lbs 3/4" ......... 35 ft-lbs

For clamp 1/2" ... 70-80 in-lbs 1" ...... 90-100 in-lbs 1 1/2" 160-180 in-lbsside screw: 5/8" ... 75-85 in-lbs 1 1/4" 120-140 in-lbs 2" ..... 160-180 in-lbs(in-lbs) 3/4" ... 80-90 in-lbs

Iron pipe (-55) is stabbed thru nut to stab depth. the nut is tightened to the required torque, which compresses the EPDM gasket, which creates a water-tight seal. the stainless steel screw or screws are tightened to the required torque, for pull-out strength.

Stainless steel screw

Anti-friction ringEPDM gasket

Stab depth

AWWA straight threads

Machined grooves

tubing

NOtE: Materials meet or exceed A.W.W.A. Standard C-800.

Stainless steel screw

Any Q Series connection can be changed to a C903 Connection. Replace the “Q” in the model number with a “K.” 3/4" or 1" only.

NEW!

Q, QA or -3Q

-22, -33, -44, -66, -67, or -68 -55

Anti-friction ring

EPDM gasket Stab depth

AWWA straight threads

iron pipe

recommended torque Chart for Mac-Pak Compression Nuts

Electrical Continuity

4700QA

Underground Water Service Fittings & Couplings

A.Y. McDONALD MFG. CO. • P.O. BOX 508 • DUBUQUE, IA 52004-0508 • tOLL FrEE 800-292-2737 • FAX [email protected] • www.aymcdonald.com4 4/07

A •

Nee

d in

sert

not a

vaila

ble

from

A.Y

. McD

onal

d M

fg. C

o.B

• N

o fit

ting

from

A.Y

. McD

onal

d M

fg. C

o. a

vaila

ble.

C •

T an

d Q

not

ava

ilabl

e fo

r 1/2

" siz

e.D

• -In

sert

stiff

eren

not

requ

ired

E • -

3Q o

nly

avai

labl

e in

3/4

" and

1" s

izes

.

A •

Nee

d in

sert

not a

vaila

ble

from

A.Y

. McD

onal

d M

fg. C

o.B

• N

o fit

ting

from

A.Y

. McD

onal

d M

fg. C

o. a

vaila

ble.

C •

T an

d Q

not

ava

ilabl

e fo

r 1/2

" siz

e.D

• -In

sert

stiff

eren

not

requ

ired

E • -

3Q o

nly

avai

labl

e in

3/4

" and

1" s

izes

.()

• Max

imum

pip

e O

.D. t

hat w

ill w

ork

with

A.Y

. McD

onal

d fit

tings

.

n T

ypes

of P

ipe/

Tub

ing

for

use

wit

h A

.Y. M

cDon

ald

Fit

ting

s (O

utsi

de D

iam

eter

s lis

ted)

*Inse

rt S

tiffe

ners

requ

ired

on a

ll fle

xibl

e pl

astic

con

nect

ions

Sha

ded

area

s in

dica

te w

here

lead

pip

e m

ay h

ave

to b

e sh

aved

to fi

t com

pres

sion

end

sho

wn.

LEA

D P

IPEu

POLY

BUTY

LENE

PO

LYET

HYLE

NE

PE

X TU

BING

PO

LYBU

TYLE

NE

ASTM

D26

62 S

IDR

7

AS

TM D

3035

TYPE

K o

r L

POLY

ETHY

LENE

AS

TM F

876

ASTM

D26

66 S

DR 9

o

r PO

LYET

HYLE

NE

SDR

9

DO

UBLE

NO

MIN

AL

COPP

ER

ASTM

D27

37 S

DR 9

SD

R 9

TUBE

SIZ

E AS

TM D

2239

SID

R 7

PVC

STEE

L

OD C

ONTR

OLLE

D ST

RONG

EX

TRA

STRO

NG

EXTR

A ST

RONG

SI

ZE

TUBE

TU

BE S

IZE

CSA

B137

.5

CLAS

S 25

0 PI

PE S

IZE

ASTM

D17

85

PIP

E PI

PE S

IZE

S or

A

XS o

r AA

XXS

or A

AA

1/

2"

.622

.6

21

.621

.6

25

.79

.836

.8

36

.7

83

.861

.9

97

.6

28

.629

.6

29

.633

.8

5 .8

44

.844

.813

.8

91

1.02

7

5/

8"

1.

004

1.06

7 1.

122

1.

034

1.09

7 1.

152

3/

4"

.872

.8

71

.871

.8

75

1.04

5 1.

046

1.04

6 1.

046

1.14

1 1.

197

1.32

1

.8

78

.879

.8

79

.883

1.

110

(1.08

9)

1.05

4 1.

054

1.05

4 1.

171

1.22

7 1.

351

1"

1.

121

1.12

0 1.

120

1.12

5 1.

329

1.31

0 1.

310

1.31

0 1.

413

1.47

7 1.

581

1.12

9 1.

130

1.13

0 1.

135

1.39

9 (1

.384)

1.

320

1.32

0 1.

320

1.44

3 1.

507

1.61

1

1 1

/4"

1.37

1 1.

370

1.37

0 1.

375

1.75

4 1.

655

1.65

5 1.

655

1.65

5 1.

750

1.87

4

1.

379

1.38

0 1.

380

1.38

5 1.

832

(1.80

4)

1.66

5 1.

665

1.66

5 1.

685

1.78

0 1.

904

1 1

/2"

1.62

1 1.

619

1.61

9 1.

625

2.05

0 1.

894

1.89

4 1.

894

1.96

9 2.

061

2.25

7

1.

630

1.63

1 1.

631

1.63

7 2.

141

(2.10

9)

1.90

6 1.

906

1.90

6 1.

999

2.09

1 2.

287

2"

2.

120

2.11

9 2.

119

2.12

5 2.

637

2.36

9 2.

369

2.36

9 2.

488

2.73

6 2.

993

2.13

0 2.

131

2.13

1 2.

137

2.74

2 (2

.709)

2.

381

2.38

1 2.

381

2.51

8 2.

766

3.02

3

Type

of

A

.Y.

-22,

Q o

r T

-22*

, Q* o

r T*

-22*

, Q* o

r T*

-22*

, Q* o

r T*

-33*

or -

3Q*

-44

-55

-44*

-6

6 -6

7 -6

8 F

ittin

gC

CC

ED

D

AA

BB

B

1 1/

4" -4

4

1 1/

2" -4

4

2" -4

4

2" -2

2

1 1/

2" -4

4 B

A CD

DD

D

Underground Water Service Fittings & Couplings

5A.Y. McDONALD MFG. CO. • P.O. BOX 508 • DUBUQUE, IA 52004-0508 • tOLL FrEE 800-292-2737 • FAX [email protected] • www.aymcdonald.com

4/07

n Insert Stiffeners - Insert Stiffeners required on all flexible plastic connections

n Installation Information

Sizes: 3/4", 1", 1 1/4", 1 1/2", 2"Sizes: 3/4", 1"•Also acceptable for use with 250 PSI

polybutylene tubing. ASTM D2666, SDR 9, CTS.

Sizes: 3/4", 1", 1 1/4", 1 1/2", 2"

6131T • PLAStICFor copper tube

size polyethyleneAStM D2737 SDr 9 - CtS

6136 • StAINLESS StEELFor ID Controlled PEP

AStM D2239 SIDr 7

6133T • StAINLESS StEELFor copper tube

size polyethyleneAStM D2737 SDr 9 - CtS

6137 • StAINLESS StEELFor OD controlled

PEP SDr9AStM D3035

Sizes: 3/4", 1", 1 1/4", 1 1/2", 2"

NEW!

Underground Water Service Fittings & Couplings

A.Y. McDONALD MFG. CO. • P.O. BOX 508 • DUBUQUE, IA 52004-0508 • tOLL FrEE 800-292-2737 • FAX [email protected] • www.aymcdonald.com6 4/07

RW=Reduced Weight *Insert stiffeners are required on all flexible plastic connections. See page 5.

55 Steel Pipe Comp. Gasket and Gripper Gasket and Gripper Gasket and Gripper Gasket and GripperSize Nut Assembly (Gasket Assembly Only Assembly for Strong Lead Assembly for XStrong Lead Assembly for XXStrong Lead and Anti-Friction ring) 55 IP Series 66 S Lead Series 67 XS Lead Series 68 XXS Lead Series1/2" ● ●

5/8" ● ● ●

3/4" ● ● ● ● ●

1" ● ● ● ● ●

11⁄4" ●

11⁄2" ● ● ●

2" ● ● ●

4700-55 4700-55GA 4700-66GA 4700-67GA 4700-68GA

22 CtS Comp. Gasket and 33 PEP Comp. Gasket and 44 PVC Comp. Gasket andSize Nut Assembly (Gasket Anti-Friction ring Only Nut Assembly (Gasket Anti-Friction ring Only Nut Assembly (Gasket Anti-Friction ring Only and Anti-Friction ring) 22 CtS Series and Anti-Friction ring) 33 PEP Series and Anti-Friction ring) 44 PVC Series1/2" ● ●

3/4" ● ● ● ● ● ●

1" ● ● ● ● ● ●

11⁄4" ● ● ● ● ● ●

11⁄4" rW ● ●

11⁄2" ● ● ● ● ● ●

11⁄2" rW ● ● ● ●

2" ● ● ● ● ● ●

2" rW ● ●

n Flare and Compression Nut Assemblies

4700-22* 4700-22GA 4700-33* 4700-33GA 4700-44 4700-44GA

Copper Flare Nut Copper Flare Nut t CtS Comp. tA CtS Comp. Gasket & Gripper 3Q PEP Comp. Gasket & Gripper Only with Anode Nut Assembly Anode Nut Assembly Assembly Only Nut Assembly Assembly OnlySize Connection (Gasket & Gripper) (Gasket & Gripper) t CtS Series (Gasket & Gripper) 3Q PEP Series 1/2" ●

3/4" ● ● ● ● ● ● ●

1" ● ● ● ● ● ● ●

11⁄4" ● ● ●

11⁄2" ● ● ●

11⁄2" rW ● ●

2" ● ● ●

2" rW ● ●

4700 4700A 4700T* 4700TA* 4700TGA 4700-3Q* 4700-3QGA

Q CtS Comp. QA CtS Comp. Gasket and Gripper Clamp Screw-Small Clamp Screw-Large K C903 Comp. K C903 GripSize Nut Assembly Anode Nut Assembly Assembly Only For Mac-Pak For Mac-Pak Nut, ring, & Seal ring Only (Gasket & Gripper) (Gasket & Gripper) Q CtS Series Nuts Nuts Assembly 1/2"

5/8"

3/4" ● ● ● ● ●

1" ● ● ● ● ●

11⁄4" ● ● ●

11⁄4" rW

11⁄2" ● ● ●

11⁄2" rW

2" ● ● ●

2" rW

4700Q* 4700QA 4700QGA 4700CSS 4700CSL 4700K 4700KGR

Fits thesesizes

Fits thesesizes

NEW!

NEW!

Underground Water Service Fittings & Couplings

7A.Y. McDONALD MFG. CO. • P.O. BOX 508 • DUBUQUE, IA 52004-0508 • tOLL FrEE 800-292-2737 • FAX [email protected] • www.aymcdonald.com

4/07

4753 4753T*

4753-3Q*

SIZES AVAILABLE

4753-33* 4753-554753-44

4753Q* 4753-22*Size NUt MNPt FLArE x MNPt t CtS Comp x MNPt Q CtS Comp x MNPt 22 CtS Comp x MNPt1/2" 1/2" 1/2" ● ●

1/2" x 3/4" 1/2" 3/4" ● ●

3/4" 3/4" 3/4" ● ● ● ●

3/4" x 1/2" 3/4" 1/2" ● ● ● ● 3/4" x 1" 3/4" 1" ● ● ● ●

1" 1" 1" ● ● ● ●

1" x 3/4" 1" 3/4" ● ● ● ●

11⁄4" 11⁄4" 11⁄4" ● ● ● ●

11⁄4" x 3/4" 11⁄4" 3/4" ● ● ●

11⁄4" x 1" 11⁄4" 1" ● ● ●

11⁄4" x 11⁄2" 11⁄4" 11⁄2" ● ● ●

11⁄2" 11⁄2" 11⁄2" ● ● ● ●

11⁄2" x 1" 11⁄2" 1" ● ● ●

11⁄2" x 11⁄4" 11⁄2" 11⁄4" ● ● ●

2" 2" 2" ● ● ● ●

2" x 11⁄2" 2" 11⁄2" ● ●

n Straight Couplings - One End Male National Pipe Thread

SIZES AVAILABLESize NUt MNPt 3Q PEP Comp x MNPt 33 PEP Comp x MNPt 44 PVC Comp. x MNPt 55 IP Comp. x MNPt3/4" 3/4" 3/4" ● ● ● ●

3/4" x 1" 3/4" 1" ● ● ● ●

1" 1" 1" ● ● ● ●

1" x 3/4" 1" 3/4" ● ● ● ●

1" x 11⁄2" 1" 11⁄2" ● ● ● ●

11⁄4" 11⁄4" 11⁄4" ● ●

11⁄4" x 1" 11⁄4" 1" ● ●

11⁄4" x 11⁄2" 11⁄4" 11⁄2" ● ●

11⁄2" 11⁄2" 11⁄2" ● ● ●

11⁄2" x 1" 11⁄2" 1" ●

11⁄2" x 11⁄4" 11⁄2" 11⁄4" ●

2" 2" 2" ● ● ●

2" x 1" 2" 1" ● ● ●

Shown here is our basic line of service fittings. Other combinations not shown in this catalog may be available. Contact us for more information

*Insert stiffeners are required on all flexible plastic connections. See page 5.

For C903 tube - Replace "Q" with "K". On "Q" Series options only 3/4" x 1" ONLYAnode/Thaw/Tracer nut available for 3/4" & 1" Flare & "T" Series and all sizes of "Q" Series.

u

uSee pages 18 & 19 for Flare conversion adapters

Underground Water Service Fittings & Couplings

A.Y. McDONALD MFG. CO. • P.O. BOX 508 • DUBUQUE, IA 52004-0508 • tOLL FrEE 800-292-2737 • FAX [email protected] • www.aymcdonald.com8 4/07

n Straight Couplings - One End Female National Pipe Thread

4754 4754T*

4754-3Q*

SIZES AVAILABLE

4754-33* 4754-554754-44

4754Q* 4754-22*Size NUt FNPt FLArE x FNPt t CtS Comp x FNPt Q CtS Comp x FNPt 22 CtS Comp x FNPt1/2" 1/2" 1/2" ● ●

3/4" 3/4" 3/4" ● ● ● ●

3/4" x 1/2" 3/4" 1/2" ● ● ●

3/4" x 1" 3/4" 1" ● ● ● ●

1" 1" 1" ● ● ● ●

1" x 3/4" 1" 3/4" ● ● ● ●

1 x 11⁄4" 1" 11⁄4" ● ● ● ●

11⁄4" 11⁄4" 11⁄4" ● ● ● ●

11⁄4" x 3/4" 11⁄4" 3/4" ● ● ●

11⁄4" x 1" 11⁄4" 1" ● ● ●

11⁄2" 11⁄2" 11⁄2" ● ● ● ●

11⁄2" x 1" 11⁄2" 1" ● ● ●

11⁄2" x 11⁄4" 11⁄2" 11⁄4" ● ● ●

2" 2" 2" ● ● ● ●

2" x 11⁄2" 2" 11⁄2" ● ●

SIZES AVAILABLESize NUt FNPt 3Q PEP Comp x FNPt 33 PEP Comp. x FNPt 44 PVC Comp. x FNPt 55 IP Comp. x FNPt1/2" x 1" 1/2" 1" ●

3/4" 3/4" 3/4" ● ● ● ●

3/4" x 1/2" 3/4" 1/2" 3/4" x 1" 3/4" 1" ● ● ● ●

1" 1" 1" ● ● ● ●

1" x 3/4" 1" 3/4" ● ● ● ●

1" x 11⁄4" 1" 11⁄4" ● ● ●

11⁄4" 11⁄4" 11⁄4" ●

11⁄4" x 11⁄2" 11⁄4" 11⁄2" ● ●

11⁄2" 11⁄2" 11⁄2" ● ● ●

11⁄2" x 3/4" 11⁄2" 3/4" ●

11⁄2" x 11⁄4" 11⁄2" 11⁄4" ● ●

2" 2" 2" ● ● ●

2" x 3/4" 2" 3/4" ● ●

2" x 1 2" 1 ● ●

Shown here is our basic line of service fittings. Other combinations not shown in this catalog may be available. Contact us for more information

For C903 tube - Replace "Q" with "K". On "Q" Series options only 3/4" x 1" ONLY

*Insert stiffeners are required on all flexible plastic connections. See page 5.

u

uSee pages 18 & 19 for Flare conversion adapters

Underground Water Service Fittings & Couplings

9A.Y. McDONALD MFG. CO. • P.O. BOX 508 • DUBUQUE, IA 52004-0508 • tOLL FrEE 800-292-2737 • FAX [email protected] • www.aymcdonald.com

4/07

n Straight Couplings

*Insert stiffeners are required on all flexible plastic connections. See page 5.

4758 4758T*

4758-3Q*

SIZES AVAILABLE

4758-33* 4758-554758-44

4758Q* 4758-22*Size NUt NUt FLArE x FLArE t CtS Comp x Q CtS Comp x 22 CtS Comp x t CtS Comp Q CtS Comp 22 CtS Comp1/2" 1/2" 1/2" ● ●

1/2" x 3/4" 1/2" 3/4" ● ●

3/4" 3/4" 3/4" ● ● ● ●

3/4" x 1" 3/4" 1" ● ● ● ●

3/4" x 11⁄4" 3/4" 11⁄4" ● ● ●

1" 1" 1" ● ● ● ●

1" x 11⁄4" 1" 11⁄4" ● ● ●

1" x 11⁄2" 1" 11⁄2" ● ● ●

11⁄4" 11⁄4" 11⁄4" ● ● ● ●

11⁄2" 11⁄2" 11⁄2" ● ● ● ●

11⁄2" x 2" 11⁄2" 2" ● ●

2" 2" 2" ● ● ● ●

21⁄2" 21⁄2" 21⁄2" ●

SIZES AVAILABLESize NUt NUt 3Q PEP Comp x 33 PEP Comp. x 44 Comp. PVC x 55 IP Comp. x 3Q PEP Comp 33 PEP Comp. 44 Comp. PVC 55 IP Comp.1/2" 1/2" 1/2" ●

3/4" 3/4" 3/4" ● ● ● ●

3/4" x 1" 3/4" 1" ● ● ● ●

3/4" x 2" 3/4" 2" ● ● ●

1" 1" 1" ● ● ● ●

11⁄4" 11⁄4" 11⁄4" ● ●

11⁄2" 11⁄2" 11⁄2" ● ● ●

2" 2" 2" ● ● ●

Shown here is our basic line of service fittings. Other combinations not shown in this catalog may be available. Contact us for more information

For C903 tube - Replace "Q" with "K". On "Q" Series options only 3/4" x 1" ONLYAnode/Thaw/Tracer nut available for 3/4" & 1" Flare & "T" Series and all sizes of "Q" Series.

u

uSee pages 18 & 19 for Flare conversion adapters

4758C T* 4758CQ* 4758C-3Q*4758C-22*SIZES AVAILABLESize NUt NUt FLArE x FLArE x FLArE x FLArE x t CtS Comp Q CtS Comp 22 CtS Comp. 3Q PEP Comp3/4" 3/4" 3/4" ● ● ●

1" 1" 1" ● ● ●

1" x 3/4" 1" 3/4" ●

u

4758C -33* 4758C -554758C -44SIZES AVAILABLESize NUt NUt FLArE x FLArE x FLArE x 33 PEP Comp 44 PVC Comp. IP Comp3/4" 3/4" 3/4" ● ● ●

1" 1" 1" ● ● ●

1" x 3/4" 1" 3/4" ● ● ●

1" x 2" 1" 2" ● ● ●

u u u

Underground Water Service Fittings & Couplings

A.Y. McDONALD MFG. CO. • P.O. BOX 508 • DUBUQUE, IA 52004-0508 • tOLL FrEE 800-292-2737 • FAX [email protected] • www.aymcdonald.com10 4/07

4758T*-33*4758T*-22*SIZES AVAILABLESize NUt NUt t CtS Comp x Q CtS Comp x t CtS Comp x 22 CtS Comp 22 CtS Comp 33 PEP Comp3/4" 3/4" 3/4" ●

3/4" x 1/2" 3/4" 1/2" ● ●

1" 1" 1" ● ●

1" x 3/4" 1" 3/4" ●

1" x 2" 1" 2" ●

2" 2" 2" ● ●

2" x 11⁄2" 2" 11⁄2" ●

n Straight Couplings

SIZES AVAILABLESize NUt NUt Q CtS Comp x 22 CtS Comp x Q CtS Comp x t CtS Comp x 33 PEP Comp 33 PEP Comp 3Q PEP Comp 44 PVC Comp3/4" 3/4" 3/4" ● ● ● ●

3/4" x 1" 3/4" 1" ● ● ●

1" 1" 1" ● ● ● ●

1" x 3/4" 1" 3/4" ● ● ●

1" x 11⁄4" 1" 11⁄4" ● 1" x 2" 1" 2" ● ● ●

11⁄2" 11⁄2" 11⁄2" ● ●

11⁄2" x 11⁄4" 11⁄2" 11⁄4" ●

2 2 2 ● ● ●

Size NUt NUt Q CtS Comp x 22 CtS Comp x t CtS Comp x Q CtS Comp x 44 PVC Comp 44 PVC Comp 55 IP Comp 55 IP Comp1/2" 1/2" 1/2" ●

3/4" 3/4" 3/4" ● ● ● ●

3/4" x 1" 3/4" 1" ● ● ● ●

1" 1" 1" ● ● ● ●

1" x 3/4" 1" 3/4" ● ● ●

1" x 11⁄4" 1" 11⁄4" ●

1" x 2" 1" 2" ● ● ● ●

11⁄2" 11⁄2" 11⁄2" ● ●

2" 2" 2" ● ● ● ●

*Insert stiffeners are required on all flexible plastic connections. See page 5.

4758T*-44

4758T*-554758-22*-44

4758-22*-33*

Shown here is our basic line of service fittings. Other combinations not shown in this catalog may be available. Contact us for more information

4758Q*-33*

4758Q*-55

4758Q*-3Q*

4758Q*-22*

4758Q*-44

uSee pages 18 & 19 for Flare conversion adapters

SIZES AVAILABLE

Underground Water Service Fittings & Couplings

11A.Y. McDONALD MFG. CO. • P.O. BOX 508 • DUBUQUE, IA 52004-0508 • tOLL FrEE 800-292-2737 • FAX [email protected] • www.aymcdonald.com

4/07

SIZES AVAILABLE 4758-33*-44 4758-44-554758-22*-55 4758-33*-55

4759T* 4759Q* 4759-22*SIZES AVAILABLE

n Straight Couplings

*Insert stiffeners are required on all flexible plastic connections. See page 5.

3-Part Unions with Internal Pipe Stop

Size NUt NUt t CtS Comp x Q CtS Comp x 22 CtS Comp x t CtS Comp Q CtS Comp 22 CtS Comp1/2" 1/2" 1/2" ●

3/4" 3/4" 3/4" ● ● ●

1" 1" 1" ● ● ●

11⁄2" 11⁄2" 11⁄2" ● ● ●

2" 2" 2" ● ● ●

4759-33* 4759-44 4759-55SIZES AVAILABLESize NUt NUt 3Q PEP Comp x 33 PEP Comp x 44 PVC Comp x 55 IP Comp x 3Q PEP Comp 33 PEP Comp 44 PVC Comp 55 IP Comp3/4" 3/4" 3/4" ● ● ● ●

4759-3Q*

For C903 tube - Replace "Q" with "K". On "Q" Series options only 3/4" x 1" ONLYAnode/Thaw/Tracer nut available for 3/4" & 1" Flare & "T" Series and all sizes of "Q" Series.

Shown here is our basic line of service fittings. Other combinations not shown in this catalog may be available. Contact us for more information

Size NUt NUt 22 CtS Comp x 33 PEP Comp x 33 PEP Comp x 44 PVC Comp x 55 IP Comp 44 PVC Comp 55 IP Comp 55 IP Comp3/4" 3/4" 3/4" ● ● ● ●

3/4" x 1" 3/4" 1" ● ● ● ●

3/4" x 2" 3/4" 2" ● ● ●

1" 1" 1" ● ● ● ●

1" x 3/4" 1" 3/4" ● ● ● ●

1" x 2" 1" 2" ●

11⁄2" 11⁄2" 11⁄2" ●

2" 2" 2" ●

SIZES AVAILABLE 4755DB 4755DBT*

Size NUt FFLr FLArE x FFLr t CtS Comp x FFLr 22 CtS Comp x FFLr Q CtS Comp x FFLr 3/4" 3/4" 3/4" ● ● ● ●

1" 1" 1" ● ● ● ●

11⁄2" 11⁄2" 2" ● ● ●

2" 2" 2" ● ● ●

4755DB-22* 4755DBQ*u

4758DB-22*-55

uSee pages 18 & 19 for Flare conversion adapters

Di-Electric Unions

Size NUt FNPt 22 CtS Comp x 22 CtS Comp Q CtS Comp x Q CtS Comp 22 CtS Comp x 55 IP Comp 3/4" 3/4" 3/4" ● ●

1" 1" 1" ● ● ●

1" x 3/4" 1" 3/4" ●

11⁄2" 11⁄2" 2" ● ●

2" 2" 2" ● ●

4758DB-22* 4758DBQ*

Underground Water Service Fittings & Couplings

A.Y. McDONALD MFG. CO. • P.O. BOX 508 • DUBUQUE, IA 52004-0508 • tOLL FrEE 800-292-2737 • FAX [email protected] • www.aymcdonald.com12 4/07

n Tees

A

B KEY tO SIZES A B 3/4" x 1"

4760 4760T*SIZES AVAILABLE

4760-33* 4760-554760-44

4760Q*

SIZES AVAILABLESize BOtH SIDE 33 PEP Comp x 44 PVC Comp x MNPt x MNPt 55 IP Comp x FNPt x FNPt ENDS OUtLEt 33 PEP Comp x 44 PVC Comp x x MNPt 55 IP Comp x x FNPt rUN 33 PEP Comp 44 PVC Comp 55 IP Comp3/4" 3/4" 3/4" ● ● ● ● ●

3/4" x 1" x 9" 3/4" 1" ● 9" end to end

1" 1" 1" ● ● ● ● ●

1" x 3/4" 1" 3/4"

1" x 11⁄4" 1" 11⁄4" 1" x 11⁄2" 1" 11⁄2" 11⁄4" 11⁄4" 11⁄4" ●

11⁄2" 11⁄2" 11⁄2" ● ● ● ●

2" 2" 2" ● ● ● ●

A

Size BOtH SIDE FLArE x FLArE t CtS Comp x Q CtS Comp x 22 CtS Comp x 3Q PEP Comp x ENDS OUtLEt x FLArE t CtS Comp x Q CtS Comp x 22 CtS Comp x 3Q PEP Comp x rUN t CtS Comp Q CtS Comp 22 CtS Comp 3Q PEP Comp1/2" 1/2" 1/2" ●

3/4" 3/4" 3/4" ● ● ● ● ●

3/4" x 1" 3/4" 1" ● ● ● ●

1" 1" 1" ● ● ● ● ●

1" x 3/4" 1" 3/4" ● ● ● ●

1" x 11⁄4" 1" 11⁄4" ● ● ● ●

1" x 11⁄2" 1" 11⁄2" ● ● ●

11⁄4" 11⁄4" 11⁄4" ● ● ●

11⁄2" 11⁄2" 11⁄2" ● ● ● ●

2" 2" 2" ● ● ● ●

Size BOtH SIDE FLArE x FLArE x 22 CtS Comp x 22 CtS Comp x 22 CtS Comp x ENDS OUtLEt FLArE Assembly 22 CtS Comp x 22 CtS Comp x 22 CtS Comp x rUN Pressure tested 33 PEP Comp 44 PVC Comp 55 IP Comp1" 1" 1" ● ● ●

2" x 1" 2" 1" ●

*Insert stiffeners are required on all flexible plastic connections. See page 5.

4760-22*-554760-22*-444760-22*-33*

4760-22* 4760-3Q*

4760P

For C903 tube - Replace "Q" with "K". On "Q" Series options only 3/4" x 1" ONLY

NEW! NEW!

u

uSee pages 18 & 19 for Flare conversion adapters

4760F

SIZES AVAILABLE 4760A

Underground Water Service Fittings & Couplings

13A.Y. McDONALD MFG. CO. • P.O. BOX 508 • DUBUQUE, IA 52004-0508 • tOLL FrEE 800-292-2737 • FAX [email protected] • www.aymcdonald.com

4/07

n Tees

A

B KEY tO SIZES A B 3/4" x 1"

4762 4762T*SIZES AVAILABLE 4762Q* 4762-22*

A

Size BOtH SIDE FLArE x t CtS Comp x Q CtS Comp x 22 CtS Comp x ENDS OUtLEt FLArE x MNPt t CtS Comp x Q CtS Comp x 22 CtS Comp x rUN MNPt MNPt MNPt3/4" 3/4" 3/4" ● ● ● ●

3/4" x 1" 3/4" 1" ● ● ● ●

1" 1" 1" ● ● ● ●

4763 4763T*SIZES AVAILABLE 4763Q* 4763-22*Size BOtH SIDE MNPt x MNPt x MNPt x MNPt x MNPt x MNPt x MNPt x MNPt x ENDS OUtLEt FLArE t CtS Comp Q CtS Comp 22 CtS Comp rUN 3/4" 3/4" 3/4" ●

3/4" x 1" 3/4" 1" ● ● ● ●

3/4" x 1" x 9" 3/4" 1" ● 9" end to end ● 9" end to end ● 9" end to end ● 9" end to end

1" 1" 1" ● ● ● ●

1" x 11⁄4" 1" 11⁄4" ● ● ● ●

1" x 11⁄2" 1" 11⁄2" ● ● ●

4764T* 4764Q*SIZES AVAILABLE 4764-22*Size BOtH SIDE t CtS Comp x Q CtS Comp x 22 CtS Comp x ENDS OUtLEt t CtS Comp x Q CtS Comp x 22 CtS Comp x rUN FNPt FNPt FNPt 3/4" 3/4" 3/4" ● ● ●

3/4" x 1" 3/4" 1" ● ● ●

1" 1" 1" ● ● ●

11⁄2" x 3/4" 11⁄2" 3/4" ● ● ●

11⁄2" x 1" 11⁄2" 1" ● ● ●

2" x 3/4" 2" 3/4" ● ● ●

2" x 1" 2" 1" ● ● ●

*Insert stiffeners are required on all flexible plastic connections. See page 5.

For C903 tube - Replace "Q" with "K". On "Q" Series options only 3/4" x 1" ONLY

Shown here is our basic line of service fittings. Other combinations not shown in this catalog may be available. Contact us for more information

u

u

uSee pages 18 & 19 for Flare conversion adapters

Underground Water Service Fittings & Couplings

A.Y. McDONALD MFG. CO. • P.O. BOX 508 • DUBUQUE, IA 52004-0508 • tOLL FrEE 800-292-2737 • FAX [email protected] • www.aymcdonald.com14 4/07

4779M 4779MT*SIZES AVAILABLE 4779MQ*Size NUt MNPt FLArE x MNPt t CtS Comp x Q CtS Comp x 22 CtS Comp x MNPt MNPt MNPt3/4" 3/4" 3/4" ● ● ● ●

1" 1" 1" ● ● ● ●

1" x 3/4" 1" 3/4" ● ● ● ●

11⁄4" x 1" 11⁄4" 1" ● ● ●

11⁄2" 11⁄2" 11⁄2" ● ● ● ●

2" 2" 2" ● ● ● ●

n Elbows • 1/4 Bend

SIZES AVAILABLESize NUt MNPt 3Q PEP Comp x 33 PEP Comp x 44 PVC Comp x 55 IP Comp x MNPt MNPt MNPt MNPt3/4" 3/4" 3/4" ● ● ● ●

1" 1" 1" ● ● ● ●

11⁄2" 11⁄2" 11⁄2" ● ●

2" 2" 2" ● ● ●

n Elbows • 1/8 Bend

Size NUt FNPt FLArE x t CtS Comp x 22 CtS Comp x FNPt FNPt FNPt 3/4" 3/4" 3/4" ●

3/4" x 1" 3/4" 1" ●

1" 1" 1" ● ● ●

1" x 11⁄4" 1" 11⁄4" ●

4747 4747T*SIZES AVAILABLE 4747-22*

*Insert stiffeners are required on all flexible plastic connections. See page 5.

4779M-22*

4779M-33* 4779M-554779M-44

Shown here is our basic line of service fittings. Other combinations not shown in this catalog may be available. Contact us for more information

For C903 tube - Replace "Q" with "K". On "Q" Series options only 3/4" x 1" ONLY

4779M-3Q*

u

u

uSee pages 18 & 19 for Flare conversion adapters

Underground Water Service Fittings & Couplings

15A.Y. McDONALD MFG. CO. • P.O. BOX 508 • DUBUQUE, IA 52004-0508 • tOLL FrEE 800-292-2737 • FAX [email protected] • www.aymcdonald.com

4/07

n Elbows • 1/4 Bend

4779 4779T*SIZES AVAILABLE 4779Q*Size NUt FNPt FLArE x t CtS Comp x Q CtS Comp x FNPt FNPt FNPt 3/4" 3/4" 3/4" ● ● ●

3/4" x 1" 3/4" 1" ● ● ●

3/4" x 11⁄4" 3/4" 1 1⁄4" ● ●

1" 1" 1" ● ● ●

1" x 11⁄4" 1" 11⁄4" ● ● ●

11⁄2" 11⁄2" 11⁄2" ● ● ●

2" 2" 2" ● ● ●

Size NUt FNPt 22 CtS Comp x 44 PVC Comp x 55 IP Comp x FNPt FNPt FNPt 3/4" 3/4" 3/4" ●

3/4" x 1" 3/4" 1" ●

3/4" x 11⁄4" 3/4" 11⁄4" ●

1" 1" 1" ●

1" x 11⁄4" 1" 11⁄4" ●

11⁄2" 11⁄2" 11⁄2" ● ●

2" 2" 2" ● ● ●

4779-22* 4779-44SIZES AVAILABLE 4779-55

4761 4761T*SIZES AVAILABLE 4761-22*4761Q*Size NUt NUt FLArE x FLArE t CtS Comp x Q CtS Comp x 22 CtS Comp x t CtS Comp Q CtS Comp 22 CtS Comp3/4" 3/4" 3/4" ● ● ● ●

1" 1" 1" ● ● ● ●

11⁄4" 11⁄4" 11⁄4" ● ● ●

11⁄2" 11⁄2" 11⁄2" ● ● ● ●

2" 2" 2" ● ● ● ●

4761-3Q* 4761-33* 4761-554761-44SIZES AVAILABLE

Size NUt NUt 3Q PEP Comp x 33 PEP Comp x 44 PVC Comp x 55 IP Comp x 44 PVC Comp x 3Q PEP Comp 33 PEP Comp 44 PVC Comp 55 IP Comp 55 IP Comp3/4" 3/4" 3/4" ● ● ● ●

1" 1" 1" ● ● ● ●

11⁄4" 11⁄4" 11⁄4" ●

11⁄2" 11⁄2" 11⁄2" ● ● ●

2" 2" 2" ● ● ● ●

*Insert stiffeners are required on all flexible plastic connections. See page 5.

For C903 tube - Replace "Q" with "K". On "Q" Series options only 3/4" x 1" ONLY

4761-44-55

u

u

uSee pages 18 & 19 for Flare conversion adapters

Underground Water Service Fittings & Couplings

A.Y. McDONALD MFG. CO. • P.O. BOX 508 • DUBUQUE, IA 52004-0508 • tOLL FrEE 800-292-2737 • FAX [email protected] • www.aymcdonald.com16 4/07

n Mac-Pak Lead Compression

4753-66 4753-67SIZES AVAILABLE 4753-68Size NUt MNPt 66 Strong Lead Comp. x 67 X Strong Lead Comp. x 68 XX Strong Lead Comp. x MNPt MNPt MNPt 1/2" x 3/4" 1/2" 3/4" ● ●

5/8" x 3/4" 5/8" 3/4" ● ● ●

3/4" 3/4" 3/4" ● ● ●

1" 1" 1" ● ● ●

11⁄4" 11⁄4" 11⁄4" ●

11⁄4" x 1" 11⁄4" 1" ●

11⁄2" 11⁄2" 11⁄2" ●

2" 2" 2" ●

4754-66 4754-67SIZES AVAILABLE 4754-68Size NUt FNPt 66 Strong Lead Comp. x 67 X Strong Lead Comp. x 68 XX Strong Lead Comp. x FNPt FNPt FNPt 1/2" x 3/4" 1/2" 3/4" ●

5/8" x 3/4" 5/8" 3/4" ● ● ●

5/8" x 1" 5/8" 1" ●

3/4" 3/4" 3/4" ● ● ●

4758-66 4758-67SIZES AVAILABLE 4758-68Size NUt NUt 66 Strong Lead Comp. x 67 X Strong Lead Comp. x 68 XX Strong Lead Comp. x 66 Strong Lead Comp. 67 X Strong Lead Comp. 68 XX Strong Lead Comp.1/2" 1/2" 1/2" ●

5/8" 5/8" 5/8" ● ●

3/4" 3/4" 3/4" ● ● ●

1" 1" 1" ● ●

11⁄4" 11⁄4" 11⁄4" ●

4758C -66 4758C -67SIZES AVAILABLE 4758C -68Size NUt NUt FLArE x FLArE x FLArE x 66 Strong Lead Comp. 67 X Strong Lead Comp. 68 XX Strong Lead Comp.3/4" 3/4" 3/4" ● ● ●

3/4" x 1/2" 3/4" 1/2" ● ●

3/4" x 5/8" 3/4" 5/8" ● ● ●

1" 1" 1" ● ● ●

1" x 1/2" 1" 1/2" ●

1" x 5/8" 1" 5/8" ● ● ●

1" x 3/4" 1" 3/4" ● ● ●

u

uSee pages 18 & 19 for Flare conversion adapters

u u

Underground Water Service Fittings & Couplings

A.Y. McDONALD MFG. CO. • P.O. BOX 508 • DUBUQUE, IA 52004-0508 • tOLL FrEE 800-292-2737 • FAX [email protected] • www.aymcdonald.com18 4/07

n Couplings for Use with Copper Flare Outlets

4755 4755T* 4755-22*SIZES AVAILABLE

4755-33* 4755-554755-44

4755Q*Size NUt FFLr FLArE x FFLR t CtS Comp x FFLR Q CtS Comp x FFLR 22 CtS Comp x FFLR1/2" x 3/4" 1/2" 3/4" ● ●

3/4" 3/4" 3/4" ● ● ●

3/4" x 1/2" 3/4" 1/2" ● ● ● ●

3/4" x 1" 3/4" 1" ● ● ● ●

1" 1" 1" ● ● ●

1" x 3/4" 1" 3/4" ● ● ● ●

1 x 11⁄4" 1" 11⁄4" ● ● ●

1 x 11⁄2" 1" 11⁄2" ● ● ●

1 x 2" 1" 2" ● ● ●

11⁄4" x 1" 11⁄4" 1" ● ● ● ●

11⁄4" x 11⁄2" 11⁄4" 11⁄2" ● ● ●

11⁄4" x 2" 11⁄4" 2" ● ● ● ●

11⁄2" 11⁄2" 11⁄2" ● ● ●

11⁄2" x 2" 11⁄2" 2" ● ● ● ●

2" 2" 2" ● ● ●

SIZES AVAILABLE

Size NUt FFLr 3Q PEP Comp x 33 PEP Comp x 44 PVC Comp x 55 IP Comp x FNPt x MNPt x FFLR FFLR FFLR FFLR FFLR FFLR1/2" 1/2" 1/2" ●

3/4" 3/4" 3/4" ● ● ● ● ● ●

3/4" x 1/2" 3/4" 1/2" ●

1" 1" 1" ● ● ● ● ● ●

1" x 3/4" 1" 3/4" ●

1 x 11⁄4" 1" 11⁄4" ●

1 x 11⁄2" 1" 11⁄2" ●

1 x 2" 1" 2" ● ●

11⁄4" x 1" 11⁄4" 1" ●

11⁄4" x 11⁄2" 11⁄4" 11⁄2" ●

11⁄4" x 2" 11⁄4" 2" ●

11⁄2" 11⁄2" 11⁄2" ● ●

11⁄2" x 2" 11⁄2" 2" ●

2" 2" 2" ● ●

2" x 11⁄2" 2" 11⁄2" ●

4755F 4755M

NOtE: 4755G Copper Gasket included with all 4755 connections.

*Insert stiffeners are required on all flexible plastic connections. See page 5.

4755-3Q*

For C903 tube - Replace "Q" with "K". On "Q" Series options only 3/4" x 1" ONLY

6130CC 6130CEFemale Copper Flare to CtS

Compression CouplingFemale Copper Flare to CtS

Compression Coupling6125 4755GSIZES AVAILABLE

COPPEr GASKEt FFLr x Copper FFLr x CtS PE CompSize FFLr END SOLID COPPEr DISC for 4755 Connections tube Comp Includes Stiffener1/2" 1/2" 1/2" ●

3/4" 3/4" 3/4" ● ● ● ●

1" 1" 1" ● ● ● ●

11⁄4" ● 11⁄2" ● 2" ●

uSee pages 18 & 19 for Flare conversion adapters

u

Underground Water Service Fittings & Couplings

19A.Y. McDONALD MFG. CO. • P.O. BOX 508 • DUBUQUE, IA 52004-0508 • tOLL FrEE 800-292-2737 • FAX [email protected] • www.aymcdonald.com

4/07

n Couplings for Use with Copper Flare Outlets

4750 4750T*SIZES AVAILABLE 4750-22*Size FFLr NUt FIXED FFLr x FLArE FIXED FFLr x t CtS Comp FIXED FFLr x 22 CtS Comp3/4" 3/4" 3/4" ● ● ●

1" 1" 1" ● ● ●

4750S 4750ST* 4750S-444750S-22*SIZES AVAILABLE

Size SWIVEL NUt Swivel FFLr x Swivel FFLr x Swivel FFLr x Swivel FFLr x Swivel FFLr x FFLr FLArE Q CtS Comp t CtS Comp 22 CtS Comp 44 PVC Comp3/4" 3/4" 3/4" ● ● ● ●

1" 1" 1" ● ● ● ●

11⁄2" 11⁄2" 11⁄2" ● ● ● ● ●2" 2" 2" ● ● ● ● ●

SIZES AVAILABLE

NOtE: 4755G Copper Gasket included with all connections on this page.

*Insert stiffeners are required on all flexible plastic connections. See page 5.

4776 4776T* 4776-22*4776Q*SIZES AVAILABLESize FFLr NUt Fixed FFLr x Fixed FFLr x Fixed FFLr x Fixed FFLr x

FLArE t CtS Comp Q CtS Comp 22 CtS Comp3/4" 3/4" 3/4" ● ● ● ●

1" 1" 1" ● ● ● ●

11⁄4" 11⁄4" 11⁄4" ● ● ●

Size SWIVEL NUt Swivel FFLr x Swivel FFLr x Swivel FFLr x Swivel FFLr x FFLr FLArE t CtS Comp Q CtS Comp 22 CtS Comp3/4" 3/4" 3/4" ● ● ● ●

1" 1" 1" ● ● ● ●

11⁄4" x 1" 1" 11⁄4" ● ● ●

11⁄2" 11⁄2" 11⁄2" ● ● ● ●

2" 2" 2" ● ● ● ●

4776S 4776ST* 4776S-22*4776SQ*

4750SQ*

Shown here is our basic line of service fittings. Other combinations not shown in this catalog may be available. Contact us for more information

SIZES AVAILABLESize SWIVEL NUt Swivel FFLr x Swivel FFLr x Swivel FFLr x Swivel FFLr x FFLr 3Q PEP Comp 33 PEP Comp 44 PVC Comp 55 IP Comp3/4" 3/4" 3/4"

1" 1" 1" ● ● ● ●

11⁄2" 11⁄2" 11⁄2" ●

2" 2" 2" ● ●

4776S-3Q* 4776S-33* 4776S-44 4776S-55*

For C903 tube - Replace "Q" with "K". On "Q" Series options only 3/4" x 1" ONLYAnode/Thaw/Tracer nut available for 3/4" & 1" Flare & "T" Series and all sizes of "Q" Series.

u

u

u

u

uSee pages 18 & 19 for Flare conversion adapters

Underground Water Service Fittings & Couplings

A.Y. McDONALD MFG. CO. • P.O. BOX 508 • DUBUQUE, IA 52004-0508 • tOLL FrEE 800-292-2737 • FAX [email protected] • www.aymcdonald.com20 4/07

n Y-Branches

0 8 Y 2 C C 1 x 3/4

B

SizeSingle opening end x Multiple opening ends

Model No. 08Y2CC 1 x 3/4 means:

All Y-Branches Number of branches2 = Two branches3 = Three branches4 = Four branchesS = Service fittings (all 2 branch)

Type of connection-Single opening endC = Copper flareK = C903 CompressionL = Copper flare, less nutM = MNPTQ = McQuik CompressionT = T CompressionZ = 3Q Compression2 = 22 Compression3 = 33 Compression4 = 44 Compression5 = 55 Compression

Type of connection-Multiple opening ends(Same codes as single opening end)

A B

A

B

08YSTT*SIZES AVAILABLE

08YSMC 08YSMT*SIZES AVAILABLE 08YSM2*Size Single Multiple MNPt x MNPt x MNPt x MNPt x

End Ends FLArE t CtS Comp 22 CtS Comp Q CtS Comp1" x 3/4" 1" 3/4" ● ● ● ●

08YS22* 08YS33* 08YS5508YS44SIZES AVAILABLESize Single Multiple 22 CtS Comp x 33 PEP Comp x 44 PVC Comp x 55 IP Comp x End Ends 22 CtS Comp 33 PEP Comp 44 PVC Comp 55 IP Comp1" x 3/4" 1" 3/4" ● ● ● ●

11⁄4" x 1" 11⁄4" 1" ●

11⁄2" x 1" 11⁄2" 1" ●

2" x 1" 2" 1" ●

*Insert stiffeners are required on all flexible plastic connections. See page 5.

08YSQQ*Size Single Multiple FLArE x Q CtS Comp x C903 Comp x t CtS Comp x 3Q PEP Comp x End Ends FLArE Q CtS Comp C903 Comp t CtS Comp 3Q PEP Comp1" x 3/4" 1" 3/4" ● ● ● ● ●

11⁄4" x 1" 11⁄4" 1" ● ●

11⁄2" x 1" 11⁄2" 1" ● ●

2" x 1" 2" 1" ● ●

08YSZZ*08YSCC

08YSMQ*

For C903 tube - Replace "Q" with "K". On "Q" Series options only 3/4" x 1" ONLY

Shown here is our basic line of service fittings. Other combinations not shown in this catalog may be available. Contact us for more information

uSee pages 18 & 19 for Flare conversion adapters

u

u

08YSKK*

Underground Water Service Fittings & Couplings

21A.Y. McDONALD MFG. CO. • P.O. BOX 508 • DUBUQUE, IA 52004-0508 • tOLL FrEE 800-292-2737 • FAX [email protected] • www.aymcdonald.com

4/07

n Y-Branches

08Y2CC 08Y2MT* 08Y2M2*08Y2MCSIZES AVAILABLESize Single Multiple FLArE x MNPt x MNPt x MNPt x MNPt x

End Ends FLArE FLArE Q CtS Comp t CtS Comp 22 CtS Comp1" x 3/4" 1" 3/4" ●

1" x 1" 1" 1" ●

11⁄4" x 3/4" 11⁄4" 3/4" ●

11⁄4" x 1" 11⁄4" 1" ●

11⁄2" x 1" 11⁄2" 1" ● ● ● ● ●

2" x 1" 2" 1" ● ● ● ● ●

08Y3CC 08Y3MCSIZES AVAILABLE

4765

Size Single Multiple FLArE x MNPt xEnd Ends FLArE FLArE

11⁄2" x 3/4" 11⁄2" 3/4" ● ●

11⁄2" x 1" 11⁄2" 1" ● ●

2" x 1" 2" 1" ● ●

08Y4CC 08Y4TT* 08Y422*08Y4QQ*SIZES AVAILABLESize Single Multiple FLArE x t CtS Comp x Q CtS Comp x 22 CtS Comp x

End Ends FLArE t CtS Comp Q CtS Comp 22 CtS Comp2" x 3/4" 2" 3/4" ● ● ● ●

2" x 1" 2" 1" ● ● ● ●

*Insert stiffeners are required on all flexible plastic connections. See page 5.

08Y4MC 08Y4MT* 08Y4M2*SIZES AVAILABLESize Single Multiple MNPt x MNPt x MNPt x MNPt x FNPt x

End Ends FLArE t CtS Comp Q CtS Comp 22 CtS Comp FNPt2" x 3/4" 2" 3/4" ● ● ● ●

2" x 1" 2" 1" ● ● ● ●

For C903 tube - Replace "Q" with "K". On "Q" Series options only 3/4" x 1" ONLY

08Y2MQ*

08Y4MQ*

u u

u u

u

u

uSee pages 18 & 19 for Flare conversion adapters

Underground Water Service Fittings & Couplings

A.Y. McDONALD MFG. CO. • P.O. BOX 508 • DUBUQUE, IA 52004-0508 • tOLL FrEE 800-292-2737 • FAX [email protected] • www.aymcdonald.com22 4/07

n U-Branches

nto order U-Branches: Model No. 08UCM 1 x 3/4 x 7.5 means:08 U C M 1 x 3/4 x 7.5 Size

Single opening end X

Multiple opening endX

Spread

U-Branchestype of connection -Single opening endC = Copper flareF = FNPTJ = Male Meter ThdK = C903 Comp.L = Copper flare, less nutM = MNPT

type of connection-Multiple openings(Same codes as single open-ing end)Style

U = Standard U-branchT = Angle U-branch

08UCM 08UTM*

08UFF*

08UQM*SIZES AVAILABLESize Single Multiple FLArE x t CtS Comp x Q CtS Comp x 22 CtS Comp x

End Ends Spread MNPt MNPt MNPt MNPt1" x 3/4" x 6.5" 1" 3/4" 6.5" ● ● ● ●

1" x 3/4" x 7.5" 1" 3/4" 7.5" ● ● ● ●

1" x 1" x 7.5" 1" 1" 7.5" ● ● ● ●

1" x 3/4" x 14"▲ 1" 3/4" 14" ● ● ● ●

1" x 1" x 18" 1" 1" 18" ● ● ● ●

11⁄2" x 3/4" x 7.5" 11⁄2 3/4" 7.5" ● ● ●

11⁄2" x 1" x 9" 11⁄2 1" 9" ● ● ●

08U2M*

08U3M* 08U5M08U4MSIZES AVAILABLESize Single Multiple 3Q PEP Comp x 33 PEP Comp x 44 PVC Comp x 55 IP Comp x End Ends Spread MNPt MNPt MNPt MNPt1" x 3/4" x 7.5" 1" 3/4" 7.5" ● ● ● ●

11⁄2" x 3/4" x 7.5" 11⁄2 3/4" 7.5" ● ●

08UFM 08UMMSIZES AVAILABLESize Single Multiple FNPt x FNPt x MNPt x Male Meter thread End Ends Spread FNPt MNPt MNPt x Meter Swivel Nuts1" x 3/4" x 6.5" 1" 3/4" 6.5" ●

1" x 3/4" x 7.5" 1" 3/4" 7.5" ● ●

1" x 1" x 7.5" 1" 1" 7.5" ● ●

1" x 3/4" x 14"▲ 1" 3/4" 14" ● ●

1" x 1" x 8" ▲ 1" 1" 8" ● 1" x 1" x 14"▲ 1" 1" 14" ● 1" x 1" x 18" 1" 1" 18" ● ● ●

11⁄2" x 3/4" x 7.5" 11⁄2 3/4" 7.5" ●

11⁄2" x 1" x 9" 11⁄2 1" 9" ●

11⁄2" x 1" x 12"▲ 11⁄2 1" 12" ●

2" x 1" x 9" 2 1" 9" ●

SIZES AVAILABLESize Single Multiple FLArE x FNPt x MNPt x t CtS Comp x 22 CtS Comp x End Ends Spread MNPt MNPt MNPt MNPt MNPt1" x 3/4" x 6.5" 1" 3/4" 6.5" ● ● ● ●

11⁄2" x 1" x 12"▲ 11⁄2 1" 12" ●

*Insert stiffeners are required on all flexible plastic connections. See page 5.

N = Meter Swivel NutQ = McQuik Comp.T = T-Comp.Z = 3Q Comp.2 = 22 Comp.3 = 33 Comp.4 = 44 Comp.5 = 55 Comp.

▲ Assembled and tested

▲ Assembled and tested

08TFM* 08T2M*08TTM*08TMM08TC M*

08UZM*

For C903 tube - Replace "Q" with "K". On "Q" Series options only 3/4" x 1" ONLY

n Angle U-Branches

u

u

uSee pages 18 & 19 for Flare conversion adapters

08UJN

U-Branches available with valve assembled - Contact Factory

Underground Water Service Fittings & Couplings

23A.Y. McDONALD MFG. CO. • P.O. BOX 508 • DUBUQUE, IA 52004-0508 • tOLL FrEE 800-292-2737 • FAX [email protected] • www.aymcdonald.com

4/07

n Miscellaneous Service FittingsSwivel with increasing IP threadGasket included

4783S 4783ST* 4783S-22*4783SQ*SIZES AVAILABLE

Size SWIVEL NUt Swivel x Swivel x Swivel x Swivel x Swivel x Swivel x FLArE t CtS Comp Q CtS Comp 22 CtS Comp 3Q PEP Comp 33 CtS Comp5/8" 5/8" 3/4" ● ● ●

3/4" 3/4" 3/4" ● ● ● ●

1" 1" 1" ● ● ●

1" x 3/4" 1" 3/4" ● ● ● ● ●

4000 46604756Quarter Bend

Swivel with increasing IP thread-4000G gasket included

two-part unionwith “wedding ring”

Copper Flare to Polyethylene Insert Coupling

4755G gasket includedSIZES AVAILABLE

Size END END Swivel x MNPt GASKEt SWIVEL FLArE x FLArE FFLr x Barbed FOr 4000 SIZE1/2" 1/2" 1/2" ●

3/4" 3/4" 3/4" ● 4749G 1" ● ●

1" 1" 1" ● ● 11⁄4" ● ●

11⁄4" 11⁄4" 11⁄4" ● 11⁄2" ●

11⁄2" 11⁄2" 11⁄2" ● ● 2" ●

2" 2" 2" ● ● 21⁄2" ● ●

3206 3208

4775N

3209SIZES AVAILABLE AWWA CC x MNPt x AWWA CC x MNPt x MNPt x MFLr x Size tHrEAD HEAD with 5/8" inside with 5/8" inside SQUArE SQUArE Square Head SQUArE Driving thread Driving thread HEAD HEAD (Short) HEAD 1/2" 1/2" 1/2" ● ● ●

5/8" 5/8" 5/8" ● ●

3/4" 3/4" 3/4" ● ● ● ● ● ●

1" 1" 1" ● ● ● ● ●

11⁄4" 11⁄4" 11⁄4" ● ● ●

11⁄2" 11⁄2" 11⁄2" ● ● ● ●

2" 2" 2"

Underground Water Service Fittings & Couplings

A.Y. McDONALD MFG. CO. • P.O. BOX 508 • DUBUQUE, IA 52004-0508 • tOLL FrEE 800-292-2737 • FAX [email protected] • www.aymcdonald.com24 4/07

NEW!4770 Tape Measure

with O.D. ScaleSide One - O.D. scale • Side Two - inches/metric

79" - 200cm

n General Information

Suffix -22, T or Q

Suffix -33

NOtE: Materials meet or exceed A.W.W.A. standard C-800.

ABBrEVIAtIONS / DEFINItIONSAWWA American Water Works Association Standard Thread / Corporation Cock, this thread has a steeper taper than Male National Pipe ThreadsCtS Copper Tube Size, copper tube (type K or L) or copper tube size polyethylene (ASTM D2737 SDR 9) or Polybutylene (ASTM D2666 SDR 9), insert stiffeners are required when using polyethylene or polybutylene.FFLR Female Copper Flared Connection Thread / inside thread, includes copper gasket.FLR Flared end with nut, for use with copper tubeFNPt Female National Pipe Thread / inside tapered threadIP Iron Pipe / Galvanized Iron Pipe (not threaded) Suffix -55IPS or PEP I.D. based polyethylene pipe, for use with polyethylene (ASTM D2239 SIDR 7) or Polybutylene (ASTM D 2662 SIDR 7), insert stiffeners are required when using polyethylene or polybutylene.MFLR Male Copper Flared Connection Thread / outside thread.MNPt Male National Pipe Thread / outside tapered threadPE PolyethylenePVC Polyvinyl Chloride, ridged plastic pipe, Schedule 40 or 80 only (ASTM D1785) Suffix -44

MODEL 4692 - 3/4", 1"Converts 3/4" & 1" CTS compression to 3/4" or 1" Flare

EPDM O-RINGS

COPPER TUBECOPPERFLARE NUT

CTS COMPRESSION TOFLARE INSERT

McDONALD CTS COMPRESSION BODY OR ENDPIECE

Flare Nut 4692 CTS Compression End

uSee pages 18 & 19 for Flare conversion adapters

NEW!

CtS COMPrESSION PLUGMODEL 4693 - 3/4", 1"Plugs 3/4" & 1" CTS

W A RNING:W A RNING:W A RNING:W A RNING:W A RNING:W A RNING:W A RNING:W A RNING:W A RNING:W A RNING:W A R NING: I t i s u n l a w f u l i n C A L I F O R NIA & VERMONT (effective 1/1/2010); MARYLAND (effective 1/1/2012); LOUISIANA (effective 1/1/2013) and the UNITED STATES OF AMERICA (effective 1/4/2014) to use any product in the installation or repair of any public water system or any plumbing in a facility or system that provides water for human consumption if the wetted surface area of the product has a weighted average lead content greater than 0.25%. This prohibition does not extend to service saddles used in California, Louisiana or under USA Public Law 111-380.

WA rNING:

W A rN I N G : 8 0 0 . 2 9 2 . 2 7 3 7 |

FAX 800.832.9296 | [email protected] | www.aymcdonald.comWATERWORKS | PUMPS | PLUMBING VALVES | GAS VALVES

A.Y. McDonald Mfg. Co.