SonicShield PLUS Installation and Operation Manual SonicShield II PLUS SonicShield III PLUS Issue 3 CMS Marine 4 St Albans Road Gloucester GL2 5FW +44 (0) 1452 380100 www.cmsmarine.co.uk [email protected]

Upload: others

Post on 08-May-2021

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ultrasonicantifoulingworks.co.uk/wp-content/... SonicShield PLUS Installation and Operation ManualInstallation of the antifouling system (control box location, transducer installation

SonicShield PLUS Installation

and Operation Manual

SonicShield II PLUS

SonicShield III PLUS

Issue 3

CMS Marine

4 St Albans Road

Gloucester

GL2 5FW

+44 (0) 1452 380100

www.cmsmarine.co.uk

[email protected]

Page 2: ultrasonicantifoulingworks.co.uk/wp-content/... SonicShield PLUS Installation and Operation ManualInstallation of the antifouling system (control box location, transducer installation

Issue 3 24/4/12 - CMS Marine - +44 (0) 1452 380100 – [email protected]

Page 1

Contents

Page 1 - Contents

Page 2 - Welcome

SonicShield PLUS Installation

Page 3 - Kit Contents + PIR Installation

Page 4 - Float Switch Installation

Page 5 - Sound Bomb Installation

Page 6 - GSM Modem Installation

Page 7 - Control Box connections

Operation Manual

Page 8 - Operation Manual Summary

Page 9 - Table of commands

Page 10 to 18 - Visual list of commands

Page 18 to 20 - Visual list of alerts / warnings

Page 3: ultrasonicantifoulingworks.co.uk/wp-content/... SonicShield PLUS Installation and Operation ManualInstallation of the antifouling system (control box location, transducer installation

Issue 3 24/4/12 - CMS Marine - +44 (0) 1452 380100 – [email protected]

Page 2

Welcome

Thank you for choosing CMS Marine to supply your SonicShield Plus.

This guide will support you through the installation of the PLUS option you have added to your

SonicShield product. The guide is split into 2 sections. The 1st section is an installation guide and the 2nd

section is the operation manual for your unit.

Installation of the antifouling system (control box location, transducer installation etc) is covered in a

separate manual. We would advise you follow the Installation manual before adding the alarm system.

If you have already installed your system please continue to follow this guide.

If you have any questions or require any help please either contact us on +44 (0) 1452 380100 or

[email protected]

Page 4: ultrasonicantifoulingworks.co.uk/wp-content/... SonicShield PLUS Installation and Operation ManualInstallation of the antifouling system (control box location, transducer installation

Issue 3 24/4/12 - CMS Marine - +44 (0) 1452 380100 – [email protected]

Page 3

SonicShield PLUS Installation

Kit Contents

X1 GSM Modem + CABLE

X1 PIR + CABLE

X1 SOUND BOMB + CABLE

X1 FLOAT SWITCH + CABLE

X1 SIM CARD (UK ONLY)

We have supplied sufficient cable for most installation requirements. If however you require a different

length of any of our cables please call us on +44 1452 380 100 to discuss

PLEASE ENSURE ALL POWER TO YOUR UNIT HAS BEEN DISCONNECTED DURING THE PLUS INSTALLATION

PROCESS.

PIR installation

The PIR (Passive InfraRed detector) supplied with your unit is Quad band and provides maximum coverage

for your boat.

Please consider the followings hints below

1. Avoid direct sunlight

2. Avoid looking directly at air conditioning or heating vents

3. Avoid vapour or high humidity (Kettles etc)

4. Avoid Curtains, Screens etc blocking detection area.

We believe the optimum area for installation is in the main cabin area, pointing directly at your hatch /

companion way.

When selecting the area of installation ensure that the PIR cable will reach your control unit. If the

optimum installation area is out of reach of the cable please contact us to discuss the options available.

Page 5: ultrasonicantifoulingworks.co.uk/wp-content/... SonicShield PLUS Installation and Operation ManualInstallation of the antifouling system (control box location, transducer installation

Issue 3 24/4/12 - CMS Marine - +44 (0) 1452 380100 – [email protected]

Page 4

You will need to remove the front cover of the PIR by removing the white cover fastening screw on the

underside of the PIR.

With the unit open you will then see x2 mounting knockouts (Pitch=2.63inch/66.7mm). Using the screws

provided you can now fix the bracket.

Replace the cover and cover fastening screw.

Float Switch Installation

THE FLOAT SWITCH IS NOT ACTIVATED IN YOUR UNIT AS A FACTORY STANDARD TO ACTIVATE YOUR

FLOAT SWITCH YOU WILL NEED TO FOLLOW THE INSTRUCTIONS IN THE OPERATION MANUAL LATER IN

THIS GUIDE USING YOUR MOBILE PHONE.

The float switch will detect the presence of water in your bilge and will alert you initially by sounding a

warning on the control unit. After 1 minute an SMS message will be sent to N1 and N2 of your programmed

numbers informing you of the float switch alarm.

You will need to attach the float switch to a bulk head in your bilge area. This can be achieved by either 2

part epoxy or you can use the screws provided. To use the screws you will need to drill through your float

switch using the guide holes that have been pre-drilled to ensure you do not disturb the internal cabling.

You will need to mount the float switch with the CMS Marine label facing out from the bulk head and the

white float must be pointing down towards the bilge.

Page 6: ultrasonicantifoulingworks.co.uk/wp-content/... SonicShield PLUS Installation and Operation ManualInstallation of the antifouling system (control box location, transducer installation

Issue 3 24/4/12 - CMS Marine - +44 (0) 1452 380100 – [email protected]

Page 5

Sound Bomb Installation

The sound bomb emits 111Db, please consider this during installation. We would recommend installing in

the saloon area for maximum effect, however if you would prefer to install out of sight this would also be

appropriate.

You can fix the sound bomb with either the screws or velcro provided.

GSM Modem Installation

The GSM Modem unit is used by your system to send and receive status messages and commands. Details

of the operation of this unit are detailed in the 2nd half of this document.

IF YOU HAVE PURCHASED THE UNIT WITHIN THE UK YOU WILL HAVE BEEN SUPPLIED A SIM CARD

PRELOADED WITH SOME CREDIT TO GET YOU STARTED.

IF YOU HAVE PURCHASED THE UNIT OUTSIDE OF THE UK YOU WILL NEED TO PURCHASE A SIM CARD

BEFOR YOUR UNIT WILL WORK.

Page 7: ultrasonicantifoulingworks.co.uk/wp-content/... SonicShield PLUS Installation and Operation ManualInstallation of the antifouling system (control box location, transducer installation

Issue 3 24/4/12 - CMS Marine - +44 (0) 1452 380100 – [email protected]

Page 6

Please insert your SIM Card into the side of your modem ensuring the gold chip is facing down. (away from)

the SonicShield Logo.

Once your SIM Card is inserted please ensure the black connector at the bottom of the modem is secure

and that the black connector at the top of the modem is fully inserted.

You should install the modem in an area of your boat that will receive the strongest mobile phone signal.

Using the velcro supplied you should mount the modem close to the control unit. We also recommend

using the plastic P-clips supplied to offer additional support to your modem cable if possible. If you require

a longer modem cable please contact us.

Page 8: ultrasonicantifoulingworks.co.uk/wp-content/... SonicShield PLUS Installation and Operation ManualInstallation of the antifouling system (control box location, transducer installation

Issue 3 24/4/12 - CMS Marine - +44 (0) 1452 380100 – [email protected]

Page 7

Fitting – All cables to the control unit

Please use the picture below to correctly connect the cables to the control unit.

ENSURE THAT NO POWER IS CONNECTED TO YOUR UNIT DURING THIS PROCESS.

Start by attaching the PIR Plug to the PIR labelled socket (Plug = 4 Pins)

Next attach the Float switch Plug to the Float switch labelled socket(Plug = 4 socket)

Next attach the Sound Bomb to the Sounder labelled socket(Plug = 3 Pins)

Finally insert the black modem connector in to the COM labelled socket.

PLEASE DO NOT INSERT ANY OTHER CABLE INTO THE COM SOCKET AS THIS HAS A LIVE POWER FEED

WHICH COULD DAMAGE ANY OTHER DEVICE CONNECTED i.e COMPUTERS.

You are now ready to power your unit on and are now able to progress to the second stage of the manual

to set up your GSM control unit.

Page 9: ultrasonicantifoulingworks.co.uk/wp-content/... SonicShield PLUS Installation and Operation ManualInstallation of the antifouling system (control box location, transducer installation

Issue 3 24/4/12 - CMS Marine - +44 (0) 1452 380100 – [email protected]

Page 8

Operation Manual

PLEASE ENSURE YOU SET UP YOUR MASTER NUMBER (N1) AND YOUR SECONDARY NUMBER (N2)

FOLLOWING THE STEPS BELOW.

The telephone number for your GSM unit can be found on the card that was supplied with your Pay as you

Go Sim card (UK ONLY). We advise that you store this number in your phone as a contact to aid set up and

also to identify your unit in the future. In our screen shots below you will see that we have named the

contact SonicShield Plus GSM.

N1 = Master Number e.g (N1=+441234111111) Mandatory

N2 = Secondary Number e.g (N2=+441234222222) Optional / Advised

PLEASE NOTE THAT WE ADVISE YOU SET BOTH N1 AND N2 TO ENSURE YOUR UNIT IS SECURE

When programming N1 you MUST send the message from the phone you want to set as N1.

Both N1 and N2 have the ability to make changes to settings and also to update the unit with alternative

numbers.

N1 and N2 CAN NOT be cleared, they can only be replaced. This is a safety feature to ensure that in the

event N1 is lost, you will still have the ability to make administration changes to the unit.

N1 and N2 will receive all status messages including entry detection, alarm arm or disable and float switch

Hi alerts.

N3, N4, N5 = Alternative numbers (Guests, Visitors, Marina etc) these numbers will only have access to the

alarm system and status updates.

Page 10: ultrasonicantifoulingworks.co.uk/wp-content/... SonicShield PLUS Installation and Operation ManualInstallation of the antifouling system (control box location, transducer installation

Issue 3 24/4/12 - CMS Marine - +44 (0) 1452 380100 – [email protected]

Page 9

TABLE OF COMMANDS

Command Example Description

N1=+ N1=+441234111111 Programs master number. The SMS MUST be sent from the phone you are registering.

N2=+ N1=+441234222222 Programs secondary number.

N3=+ N1=+441234333333 Programs tertiary numbers

N4=+ N1=+441234444444 Programs tertiary numbers

N5=+ N1=+441234555555 Programs tertiary numbers

N#=CLR N3=CLR Deletes / Clears the number saved in location 3,4 or 5. N1 and N2 can not be cleared.

N? N? Returns list of programmed numbers

Complete Complete Returns a complete status of the system

Query Query Returns a summary of the status

Alarm=On Alarm=On Arms the Alarm system

Alarm=Off Alarm=Off Disables the Alarm system

Exit=# Exit=30 (30 seconds) Sets the exit time before arming the unit. Min 10sec Max 99sec

Entry=# Entry=30 (30 seconds) Sets the entry time before the alarm will be tripped. Min 10sec Max 99sec

Delay=On Delay=On Activates the delay sound bomb function

Delay=Off Delay=Off Deactivates the delay sound bomb function

Float=On Float=On Activates the bilge float switch

Float=Off Float=Off Deactivates the bilge float switch (Factory Standard)

History History Returns a list of the last 10 message sent from your unit.

Pir Count=# PIR COUNT=2 Sets the sensitivity of the PIR. Min 1 Max 3

Shield=On SonicShield On Turns the SonicShield antifouling on

Shield=Off SonicShield Off Turns the SonicShield antifouling off

Rearm=? Rearm=3 Sets the number of times the alarm will rearm if activated. Min 0 (No rearm) Max 3

Page 11: ultrasonicantifoulingworks.co.uk/wp-content/... SonicShield PLUS Installation and Operation ManualInstallation of the antifouling system (control box location, transducer installation

Issue 3 24/4/12 - CMS Marine - +44 (0) 1452 380100 – [email protected]

Page 10

Below is a complete list of screen shots showing the command sent in Blue and the response from the unit

in Yellow. The layout of the message will of course be dependent on your phone type but the commands

and responses will be the same.

N1=

Number setup

The example opposite shows the

process to set up N1.

To set up N2 – N5 follow the same

process substituting N1 for N2 etc.

N?

Number Query

To view a list of the programmed

numbers in your unit send N?

Page 12: ultrasonicantifoulingworks.co.uk/wp-content/... SonicShield PLUS Installation and Operation ManualInstallation of the antifouling system (control box location, transducer installation

Issue 3 24/4/12 - CMS Marine - +44 (0) 1452 380100 – [email protected]

Page 11

COMPLETE

Complete Status

This is the most detailed status

available.

It provides a list of all of the

programmed settings and also

displays a status of the power,

credit, alarm, SonicShield and float.

This message will be automatically

sent once per week to N1 and N2

Query

Query

This is a summary of the most

important information.

It provides the status of your

12v/24v battery supply, the

operating voltage of your Mains /

Shore power PSU, the remaining

credit, Alarm status, SonicShield

status and Float status.

This can be used for a Quick check

on the status of your system

Page 13: ultrasonicantifoulingworks.co.uk/wp-content/... SonicShield PLUS Installation and Operation ManualInstallation of the antifouling system (control box location, transducer installation

Issue 3 24/4/12 - CMS Marine - +44 (0) 1452 380100 – [email protected]

Page 12

Alarm=On

Alarm ON

This command will Arm the alarm.

The response of ‘Override’ is

detailing that although the key

switch may show the alarm to be

off, the unit has overridden the Key

with the text message sent.

N.B If you do not get a response

your alarm may not be set. You can

check by sending a ‘QUERY’

message.

Alarm=Off

Alarm OFF

This command will Disarm the

alarm.

You will need to wait for the

response before entering your

boat.

N.B If you do not get a response

your alarm may not be disarmed.

You can check by sending a

‘QUERY’ message.

Page 14: ultrasonicantifoulingworks.co.uk/wp-content/... SonicShield PLUS Installation and Operation ManualInstallation of the antifouling system (control box location, transducer installation

Issue 3 24/4/12 - CMS Marine - +44 (0) 1452 380100 – [email protected]

Page 13

EXIT=#

EXIT

This command will change the exit

time before your alarm will be set.

It allows you to tailor the exit time

to your preference.

The exit countdown will start as

soon as the PIR light is off i.e no

further movement is detected)

The minimum is 10 seconds and the

maximum is 99 seconds.

The response is the same as the

Complete status however you will

see the Exit Delay has changed.

ENTRY=#

ENTRY

This command is the same as exit

but sets the time between entry

and tripped status on your alarm.

It allows you to tailor the entry

time to your preference.

The entry countdown will start as

soon as the PIR detects movement.

This command is also used in

conjunction with Delay=ON/OFF.

Page 15: ultrasonicantifoulingworks.co.uk/wp-content/... SonicShield PLUS Installation and Operation ManualInstallation of the antifouling system (control box location, transducer installation

Issue 3 24/4/12 - CMS Marine - +44 (0) 1452 380100 – [email protected]

Page 14

DELAY=ON

DELAY

This command will activate the

delayed sound bomb function.

If entry is detected and the delay

function is activated the control

unit will stay silent until the last 5

seconds of your preset entry time.

This function will NOT attract the

attention of an intruder to the

presence of an alarm system on

board before the sound bomb is

activated.

DELAY=OFF

DELAY

This command will deactivate the

delayed sound bomb function.

If entry is detected the control unit

will sound for the duration of the

preset entry time. If the unit is not

deactivated before the preset time

the sound bomb will be activated

This function will alert an intruder

to the presence of an alarm system

on board before the sound bomb is

activated.

Page 16: ultrasonicantifoulingworks.co.uk/wp-content/... SonicShield PLUS Installation and Operation ManualInstallation of the antifouling system (control box location, transducer installation

Issue 3 24/4/12 - CMS Marine - +44 (0) 1452 380100 – [email protected]

Page 15

FLOAT=ON

FLOAT

This command will activate the

bilge float switch on your unit.

The factory default is Float=OFF.

For details on the report the float

will send see ‘Float Alarm Hi’ in the

Warning and Status section.

FLOAT=OFF

FLOAT

This command will deactivate the

bilge float switch.

Page 17: ultrasonicantifoulingworks.co.uk/wp-content/... SonicShield PLUS Installation and Operation ManualInstallation of the antifouling system (control box location, transducer installation

Issue 3 24/4/12 - CMS Marine - +44 (0) 1452 380100 – [email protected]

Page 16

HISTORY

HISTORY

This command is for diagnostic

purposes and displays, in code

format the last 8 messages sent

from your modem unit.

For a detail of the code contact

[email protected]

N.B this information may be

requested when contacting us for

technical support.

PIR COUNT=#

PIR

This command sets the sensitivity

of your PIR.

Min = 1, Max =3. 1 is most sensitive

and 3 is least sensitive. Factory

default is 2.

If you are receiving ‘False’ alarm

messages where no intruder has

been detected you can decrease

the sensitivity of the PIR.

Page 18: ultrasonicantifoulingworks.co.uk/wp-content/... SonicShield PLUS Installation and Operation ManualInstallation of the antifouling system (control box location, transducer installation

Issue 3 24/4/12 - CMS Marine - +44 (0) 1452 380100 – [email protected]

Page 17

SHIELD=ON

Shield ON

This command will activate the

transducers for the SonicShield.

The response of ‘Override’ is

detailing that although the on/off

switch may show the SonicShield to

be off, the unit has overridden the

switch with the text message sent.

The transducers will now be

running.

SHIELD=OFF

Shield OFF

This command will deactivate the

transducers for the SonicShield.

The response of ‘Override’ is

detailing that although the on/off

switch may show the SonicShield to

be on, the unit has overridden the

switch with the text message sent.

The transducers will now be off.

Page 19: ultrasonicantifoulingworks.co.uk/wp-content/... SonicShield PLUS Installation and Operation ManualInstallation of the antifouling system (control box location, transducer installation

Issue 3 24/4/12 - CMS Marine - +44 (0) 1452 380100 – [email protected]

Page 18

WARNING MESSAGES / STATUS MESSAGES

ENTRY DETECTED

The unit will send this message

when the alarm is SET and the PIR is

activated.

It is informing you that motion has

been detected by the PIR.

This message will either be followed

by ALARM TRIPPED OR FALSE

ALARM.

REARM=#

REARM

This command will set the number

of times your alarm will

automatically rearm after the alarm

has Tripped.

Min 0 (off), Max 3. Factory default

is 3.

Page 20: ultrasonicantifoulingworks.co.uk/wp-content/... SonicShield PLUS Installation and Operation ManualInstallation of the antifouling system (control box location, transducer installation

Issue 3 24/4/12 - CMS Marine - +44 (0) 1452 380100 – [email protected]

Page 19

FOLLOWED BY EITHER

OR

ALARM TRIPPED

The unit will send this message

when the Alarm has tripped.

This will occur if no action has been

taken after ENTRY DETECTED has

been received.

The sound bomb will have been

activated.

To reset the alarm you can text the

Alarm On command or if ReArm is

set the unit will reset itself.

FALSE ALARM

The unit will send this message

when the PIR has detected

movement but has not activated the

alarm.

The sound bomb will NOT have

been activated. Your system status

has not changed.

The FALSE ALARM message is linked

to the PIR COUNT (sensitivity)

command.

Page 21: ultrasonicantifoulingworks.co.uk/wp-content/... SonicShield PLUS Installation and Operation ManualInstallation of the antifouling system (control box location, transducer installation

Issue 3 24/4/12 - CMS Marine - +44 (0) 1452 380100 – [email protected]

Page 20

Float Alarm - HI

The unit will send this message to

N1 and N2 when the float switch

monitor in the bilge has been

activated.

The FLOAT detail has changed to =

HI.

This may indicate excess water in

the bilge area and will need to be

checked.

Last Error Reset - Float

The unit will send this message to

N1 and N2 if the float switch

monitor detects normal position

has occurred.

The FLOAT detail has changed to =

OK

Page 22: ultrasonicantifoulingworks.co.uk/wp-content/... SonicShield PLUS Installation and Operation ManualInstallation of the antifouling system (control box location, transducer installation

Issue 3 24/4/12 - CMS Marine - +44 (0) 1452 380100 – [email protected]

Page 21

CMS Marine

+44 (0) 1452 380100

www.cmsmarine.co.uk

[email protected]

Low Volts

The unit will send this message to

N1 and N2 when the intelligent

control unit detects a drop in

battery voltage.

The VB12 detail will change to =

<11.60.

Or

The VB24 detail will change to =

<23.20

Last Error Reset – Battery

The battery voltage has recovered.

The VB12 detail will change to =

>11.60.

Or

The VB24 detail will change to =

>23.20