Copyright 2012 Bruker Corporation. All Rights Reserved. Chemical and Applied Markets Ultra-sensitive Detection of Pharmaceutical and Personal Care Products (PPCPs) in Water with an Integrated On-Line Extraction-UHPLC-MS/MS System Helen Sun, Ph.D. Bruker Corporation, Chemical and Applied Markets (CAM)

Upload: vanhanh

Post on 04-Jun-2018

219 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Ultra-sensitive Detection of Pharmaceutical and Personal ...nemc.us/docs/2013/presentations/Thu-Topics in Drinking Water-23.6... · 2,4-D pesticide/herbicide Ametryn pesticide/herbicide

Copyright 2012 Bruker Corporation. All Rights Reserved.

C h e m i c a l a n d A p p l i e d M a r k e t s

Ultra-sensitive Detection of Pharmaceutical and Personal Care Products (PPCPs) in Water with an

Integrated On-Line Extraction-UHPLC-MS/MS System

Helen Sun, Ph.D.

Bruker Corporation,

Chemical and Applied Markets (CAM)

Page 2: Ultra-sensitive Detection of Pharmaceutical and Personal ...nemc.us/docs/2013/presentations/Thu-Topics in Drinking Water-23.6... · 2,4-D pesticide/herbicide Ametryn pesticide/herbicide

Copyright 2012 Bruker Corporation. All Rights Reserved.

C h e m i c a l a n d A p p l i e d M a r k e t s

Pharmaceutical and Personal Care Products (PPCPs)

PPCP category: • Prescription medicine • Over-the-counter drugs • Veterinary drugs • Fragrances • Cosmetics • Sun-screen products • Diagnostic reagents • Nutraceuticals (e.g., Vitamins)

Page 3: Ultra-sensitive Detection of Pharmaceutical and Personal ...nemc.us/docs/2013/presentations/Thu-Topics in Drinking Water-23.6... · 2,4-D pesticide/herbicide Ametryn pesticide/herbicide

Copyright 2012 Bruker Corporation. All Rights Reserved.

C h e m i c a l a n d A p p l i e d M a r k e t s

Examples of PPCPs

PPCP name Classification Ibuprofen Analgesic

Gemfibrozil Antilipemic

Cimetidine Anti-acid reflux

Acetaminophen Antipyretic, Analgesic

Thiabendazole Fungicide and parasiticide

Sulfadimethoxine Sulfonamide antibiotic

Caffeine Stimulant

Bisphenol A Plasticizer

Cholesterol Sterol

Testosterone Sex Hormone

Estrogen Sex Hormone

Benzylecgonine Cocaine metabolite, drug of abuse

Page 4: Ultra-sensitive Detection of Pharmaceutical and Personal ...nemc.us/docs/2013/presentations/Thu-Topics in Drinking Water-23.6... · 2,4-D pesticide/herbicide Ametryn pesticide/herbicide

Copyright 2012 Bruker Corporation. All Rights Reserved.

C h e m i c a l a n d A p p l i e d M a r k e t s

Source of PPCPs

Page 5: Ultra-sensitive Detection of Pharmaceutical and Personal ...nemc.us/docs/2013/presentations/Thu-Topics in Drinking Water-23.6... · 2,4-D pesticide/herbicide Ametryn pesticide/herbicide

Copyright 2012 Bruker Corporation. All Rights Reserved.

C h e m i c a l a n d A p p l i e d M a r k e t s

PPCPs: impact to the planet

Potential risk to environment

Potential risk to ecological system

Potential risk to human

Potential risk to water resource

Page 6: Ultra-sensitive Detection of Pharmaceutical and Personal ...nemc.us/docs/2013/presentations/Thu-Topics in Drinking Water-23.6... · 2,4-D pesticide/herbicide Ametryn pesticide/herbicide

Copyright 2012 Bruker Corporation. All Rights Reserved.

C h e m i c a l a n d A p p l i e d M a r k e t s

Monitoring PPCPs in water

Ternes, Thomas A. Human Pharmaceuticals, Hormones And Fragrances: The Challenge of Micropollutants in Urban Water Management, IWA Publishing

Levels of PPCPs detected in the treated municipal waste water

Analytical challenges for PPCP monitor in water: • Trace amount of analyte • Multi-residue analysis

It requires a sensitive instrument with high speed analysis capability

Page 7: Ultra-sensitive Detection of Pharmaceutical and Personal ...nemc.us/docs/2013/presentations/Thu-Topics in Drinking Water-23.6... · 2,4-D pesticide/herbicide Ametryn pesticide/herbicide

Copyright 2012 Bruker Corporation. All Rights Reserved.

C h e m i c a l a n d A p p l i e d M a r k e t s

LC-MS/MS for PPCP analysis in water

0

50

100

150

200

250

300

2007 2008 2009 2010 2011 2012

Published PPCP studies by LC-MS/MS

Page 8: Ultra-sensitive Detection of Pharmaceutical and Personal ...nemc.us/docs/2013/presentations/Thu-Topics in Drinking Water-23.6... · 2,4-D pesticide/herbicide Ametryn pesticide/herbicide

Copyright 2012 Bruker Corporation. All Rights Reserved.

C h e m i c a l a n d A p p l i e d M a r k e t s

LC-MS/MS for PPCP quantitation

targeted analysis, high accuracy

MRM mode of LC-MS/MS for quantitation

Page 9: Ultra-sensitive Detection of Pharmaceutical and Personal ...nemc.us/docs/2013/presentations/Thu-Topics in Drinking Water-23.6... · 2,4-D pesticide/herbicide Ametryn pesticide/herbicide

Copyright 2012 Bruker Corporation. All Rights Reserved.

C h e m i c a l a n d A p p l i e d M a r k e t s

Sample preparation for PPCP analysis in water

Pre-concentration step: improve sensitivity

Offline solid phase extraction • Labor intensive • High consumable cost

HPLC online extraction • Automatic, less labor intensive • Two pump systems, complicates

plumbing diagram

Page 10: Ultra-sensitive Detection of Pharmaceutical and Personal ...nemc.us/docs/2013/presentations/Thu-Topics in Drinking Water-23.6... · 2,4-D pesticide/herbicide Ametryn pesticide/herbicide

Copyright 2012 Bruker Corporation. All Rights Reserved.

C h e m i c a l a n d A p p l i e d M a r k e t s

EVOQ LC-TQ online extraction (OLE)

• On-Line Extraction (OLE) • Binary + Loading pump • Same foot-print

• Bruker Advance™ UHPLCOLE: The first UHPLC with an integrated third pump for online extraction

• Maximum Performance and Flexibility

• OLE Applications: • Sample online pre-concentration • Dual trap capability • Matrix elimination

Page 11: Ultra-sensitive Detection of Pharmaceutical and Personal ...nemc.us/docs/2013/presentations/Thu-Topics in Drinking Water-23.6... · 2,4-D pesticide/herbicide Ametryn pesticide/herbicide

Copyright 2012 Bruker Corporation. All Rights Reserved.

C h e m i c a l a n d A p p l i e d M a r k e t s

Bruker LC-TQ Advantage

Advance HPLC, UHPLC (15,000 psi), & UHPLC-OLE (3 pumps in same cabinet) configuration

with built-in column oven and low dead-volume (60uL)

Industry work-horse PAL auto-sampler Vacuum insulated probe - Heated ESI

(VIP-HESI) with Active Exhaust for high-flow sensitivity & robustness

Dual inter-laced Ion funnels for sustained high-sensitivity

Lens-free collision cell design for maximum productivity

Detector technology for fast pos/neg switching & excellent negative ion

performance

Designed for a singular purpose – to reliably quantify thousands of real samples in the fastest ‘sample-to-report’ time possible

Page 12: Ultra-sensitive Detection of Pharmaceutical and Personal ...nemc.us/docs/2013/presentations/Thu-Topics in Drinking Water-23.6... · 2,4-D pesticide/herbicide Ametryn pesticide/herbicide

Copyright 2012 Bruker Corporation. All Rights Reserved.

C h e m i c a l a n d A p p l i e d M a r k e t s

The Bruker LC-TQ Advantage Food Testing –Clenbuterol as a contaminant in meat

• Clenbuterol is a sympathomimetic amine (beta-2 agonist). • Side-effect is an increases in basal metabolism rates, which

helps build muscle mass, while reducing body-fat. • Major outbreak in China which sickened over 900 people • Over 17 livestock houses closed in Mexico due to 100% of

samples testing positive for clenbuterol

• EVOQ LC-TQ Advantage • Turn-key method on the EVOQ LC-TQ • Sustained high sensitivity –proof statement available • Available in Compound Based Screening library Day 1

Day 2

Day 3

Day 4

Page 13: Ultra-sensitive Detection of Pharmaceutical and Personal ...nemc.us/docs/2013/presentations/Thu-Topics in Drinking Water-23.6... · 2,4-D pesticide/herbicide Ametryn pesticide/herbicide

Copyright 2012 Bruker Corporation. All Rights Reserved.

C h e m i c a l a n d A p p l i e d M a r k e t s

Advance UHPLCOLE Pump configuration: Single Trap

Waste

CTC

MS

Column Oven

A B

Wash In

Wash Out

A B Solvent A

Solvent B

Mixer Purge valve

Purge out

OLE solvent

Purge valve

Waste

1

2

3 4

5

6

1

2

3

4

5 6

7

8

9

10

Maximum Pressure: 100 Mpa/1000 bar/15,000 psi

OLE loading mode

Page 14: Ultra-sensitive Detection of Pharmaceutical and Personal ...nemc.us/docs/2013/presentations/Thu-Topics in Drinking Water-23.6... · 2,4-D pesticide/herbicide Ametryn pesticide/herbicide

Copyright 2012 Bruker Corporation. All Rights Reserved.

C h e m i c a l a n d A p p l i e d M a r k e t s

Advance UHPLCOLE Pump configuration: Single Trap

Waste

CTC

MS

Column Oven

A B

Wash In

Wash Out

A B Solvent A

Solvent B

Mixer Purge valve

Purge out

OLE solvent

Purge valve

Waste

1

2

3 4

5

6

1 2

3

4

5 6

7

8

9

10

Maximum Pressure: 100 Mpa/1000 bar/15,000 psi

OLE analyzing mode

Page 15: Ultra-sensitive Detection of Pharmaceutical and Personal ...nemc.us/docs/2013/presentations/Thu-Topics in Drinking Water-23.6... · 2,4-D pesticide/herbicide Ametryn pesticide/herbicide

Copyright 2012 Bruker Corporation. All Rights Reserved.

C h e m i c a l a n d A p p l i e d M a r k e t s

Waste

CTC

MS

Column Oven

A B

Wash In

Wash Out

A B Solvent A

Solvent B

Mixer Purge valve

Purge out

OLE solvent

Purge valve

1

2

3 4

5

6

Waste

1

2

3

4

5 6

7

8

9

10

Advance UHPLCOLE Pump configuration: Dual Trap

Analyzing Trap 1 Loading Trap 2

Page 16: Ultra-sensitive Detection of Pharmaceutical and Personal ...nemc.us/docs/2013/presentations/Thu-Topics in Drinking Water-23.6... · 2,4-D pesticide/herbicide Ametryn pesticide/herbicide

Copyright 2012 Bruker Corporation. All Rights Reserved.

C h e m i c a l a n d A p p l i e d M a r k e t s

Waste

CTC

MS

Column Oven

A B

Wash In

Wash Out

A B Solvent A

Solvent B

Mixer Purge valve

Purge out

OLE solvent

Purge valve

1

2

3 4

5

6

Waste

1 2

3

4

5 6

7

8

9

10

Advance UHPLCOLE Pump configuration: Dual Trap

Loading Trap 1 Analyzing Trap 2

Page 17: Ultra-sensitive Detection of Pharmaceutical and Personal ...nemc.us/docs/2013/presentations/Thu-Topics in Drinking Water-23.6... · 2,4-D pesticide/herbicide Ametryn pesticide/herbicide

Copyright 2012 Bruker Corporation. All Rights Reserved.

C h e m i c a l a n d A p p l i e d M a r k e t s

EVOQ OLE – lowering detection limit

Page 18: Ultra-sensitive Detection of Pharmaceutical and Personal ...nemc.us/docs/2013/presentations/Thu-Topics in Drinking Water-23.6... · 2,4-D pesticide/herbicide Ametryn pesticide/herbicide

Copyright 2012 Bruker Corporation. All Rights Reserved.

C h e m i c a l a n d A p p l i e d M a r k e t s

EVOQ OLE application – PPCP quantitation in city tap water samples and river water

Page 19: Ultra-sensitive Detection of Pharmaceutical and Personal ...nemc.us/docs/2013/presentations/Thu-Topics in Drinking Water-23.6... · 2,4-D pesticide/herbicide Ametryn pesticide/herbicide

Copyright 2012 Bruker Corporation. All Rights Reserved.

C h e m i c a l a n d A p p l i e d M a r k e t s

PPCP compounds Category Alprazolam anxiolytic

Ciproxacin antibiotic

Sulfamethoxazole antibiotic

Trimethoprim antibiotic

Carbamazepine anticonvulsant

2,4-D pesticide/herbicide

Ametryn pesticide/herbicide

Atrazine pesticide/herbicide

Bentazone pesticide/herbicide

Carboxine pesticide/herbicide

Cyanazine pesticide/herbicide

Diuron pesticide/herbicide

Hexazinone pesticide/herbicide

Hydroxy Atrazine pesticide/herbicide

MCPA pesticide/herbicide

Mecoprop pesticide/herbicide

Metolachlor pesticide/herbicide

Metribuzin pesticide/herbicide

Prometryn pesticide/herbicide

Pyriproxyfen pesticide/herbicide

Simazine pesticide/herbicide

Thiabendazole pesticide/parasiticide

Dapoxetine prescription drug

Sildenafil prescription drug

Caffeine stimulant

PPCP list

Page 20: Ultra-sensitive Detection of Pharmaceutical and Personal ...nemc.us/docs/2013/presentations/Thu-Topics in Drinking Water-23.6... · 2,4-D pesticide/herbicide Ametryn pesticide/herbicide

Copyright 2012 Bruker Corporation. All Rights Reserved.

C h e m i c a l a n d A p p l i e d M a r k e t s

Experimental condition

• LC

OLE pump • Flow rate: 500 µL/min • Gradient: isocratic, 100% H2O + 0.1% FA • Column: YMC-Pack Pro ODS-AQ,

35mm × 2.0 mm, 3 µm • Injection volume: 400 µL

UHPLC binary pump • Flow rate: 400 µL/min • Solvent A: H2O + 5mM NH4OAc • Solvent B: MeOH • Column: YMC-Pack Pro C18 RS, 50mm × 2.0 mm, 3 µm • Gradient run: 1 5 min

• MS condition • Bruker Advance UHPLCOLE

Instrument • Bruker EVOQ Elite

Ion source condition

• HESI: ±4000 V • Cone gas flow: 15 unit • Cone temp: 300 °C • Heated Probe gas: 50 unit • Heated Probe temp: 450 °C • Nebulizer gas flow: 50 unit • Exhaust gas: on

• Sample preparation • Water sample acidified to

0.1% FA and filtered (0.45µm)

Page 21: Ultra-sensitive Detection of Pharmaceutical and Personal ...nemc.us/docs/2013/presentations/Thu-Topics in Drinking Water-23.6... · 2,4-D pesticide/herbicide Ametryn pesticide/herbicide

Copyright 2012 Bruker Corporation. All Rights Reserved.

C h e m i c a l a n d A p p l i e d M a r k e t s

Selected PPCPs at 2 ppt

Page 22: Ultra-sensitive Detection of Pharmaceutical and Personal ...nemc.us/docs/2013/presentations/Thu-Topics in Drinking Water-23.6... · 2,4-D pesticide/herbicide Ametryn pesticide/herbicide

Copyright 2012 Bruker Corporation. All Rights Reserved.

C h e m i c a l a n d A p p l i e d M a r k e t s

Linearity, 1 ppt – 100 ppt

Trimethoprim

R2=0.999

Carbamazepine R2=0.999

Naproxen R2=0.999

Triclosan

R2=0.998

Gemfibrozil

R2=0.997

Sulfamethoxazole R2=0.999

Page 23: Ultra-sensitive Detection of Pharmaceutical and Personal ...nemc.us/docs/2013/presentations/Thu-Topics in Drinking Water-23.6... · 2,4-D pesticide/herbicide Ametryn pesticide/herbicide

Copyright 2012 Bruker Corporation. All Rights Reserved.

C h e m i c a l a n d A p p l i e d M a r k e t s

Summary of PPCPs in Water

Compound Name

RT (min)

ESI R2

S/N (p/p) 2 ppt

RSD% n=10

(5ppt) Tap Water 1 Tap Water 2

Creek Water

Bottled Water

pg/mL (ppt) Trimethoprim 1.66 + 0.994 389 5.80% <2 <2 5 <2

Hydroxy Atrazine 1.88 + 0.997 61 9.20% 4 <2 7 <2 Thiabendazole 1.93 + 0.996 408 8.70% ND <2 <2 <2

Ciproxacin 2.03 + 0.999 25 4.90% ND ND ND ND Caffeine 2.19 + 0.995 68 8.00% ND <2 <2 10 Sildenafil 2.33 + 0.998 132 6.60% ND ND ND <2

Sulfamethoxazole 2.51 + 1 68 5.00% <2 <2 ND <2 Cyanazine 4.1 + 0.998 201 8.70% ND ND ND <2 Simazine 4.38 + 1 56 9.40% 3 <2 5 ND

Metribuzin 4.39 + 0.999 26 12.50% ND ND ND ND Hexazinone 4.42 + 0.997 553 4.90% 17 3 3 ND Dapoxetine 4.62 + 0.999 268 6.00% ND ND ND ND Bentazone 4.69 - 0.999 360 6.20% ND ND ND ND Ametryn 4.73 + 0.997 404 5.70% ND ND <2 ND

Carboxine 4.8 + 0.999 217 6.20% ND ND ND ND Carbamazepine 4.85 + 0.999 485 4.50% <2 <2 <2 ND

Atrazine 5.2 + 0.996 39 6.90% <2 ND ND ND Alpazolam 5.38 + 0.998 178 5.90% ND ND ND ND

Diuron 5.54 + 0.999 56 3.60% 9 <2 6.2 ND Prometryn 5.56 + 0.994 376 8.40% ND ND ND <2

2,4-D 5.7 - 1 26 5.60% 9 <2 13 <2 MCPA 5.81 - 1 56 3.80% <2 <2 <2 ND

Mecoprop 6.39 - 1 27 2.90% <2 <2 11 2 Metolachlor 6.76 + 0.996 177 9.20% 22 <2 <2 <2 Pyriproxifen 8.36 + 1 23 3.50% ND <2 ND <2

Page 24: Ultra-sensitive Detection of Pharmaceutical and Personal ...nemc.us/docs/2013/presentations/Thu-Topics in Drinking Water-23.6... · 2,4-D pesticide/herbicide Ametryn pesticide/herbicide

Copyright 2012 Bruker Corporation. All Rights Reserved.

C h e m i c a l a n d A p p l i e d M a r k e t s

Hexazinone

• Broad spectrum herbicide • Inhibits photosynthesis • Used to control grasses,

wood plants • High water solubility • A pervasive groundwater

contaminant

Page 25: Ultra-sensitive Detection of Pharmaceutical and Personal ...nemc.us/docs/2013/presentations/Thu-Topics in Drinking Water-23.6... · 2,4-D pesticide/herbicide Ametryn pesticide/herbicide

Copyright 2012 Bruker Corporation. All Rights Reserved.

C h e m i c a l a n d A p p l i e d M a r k e t s

Metolachlor

• Chloroacetanilide herbicide • Has been detected in ground

and surface water through out US (0.08 – 4.5 ppb)

• Category C pesticide by US EPA • Bioaccumulation of

metolachlor in edible species of fish

• US EPA health advisory level (HAL): 0.525 ppm

Page 26: Ultra-sensitive Detection of Pharmaceutical and Personal ...nemc.us/docs/2013/presentations/Thu-Topics in Drinking Water-23.6... · 2,4-D pesticide/herbicide Ametryn pesticide/herbicide

Copyright 2012 Bruker Corporation. All Rights Reserved.

C h e m i c a l a n d A p p l i e d M a r k e t s

Summary

• EVOQ OLE system provides a total solution for trace PPCP quantitation in water samples: automatic online extraction followed by LC-MS/MS targeted analysis

• An MRM based LC-MS/MS method has been developed for PPCP quantitation in city water, creek water and bottled water samples

• Quantitation result shows that the water quality between cities is slightly different, weed killer herbicides were screened in the tested water samples, but the concentration is still within safety range

• EVOQ OLE system is a ease-of-use, sensitive and robust instrument for PPCP analysis in water samples

Page 27: Ultra-sensitive Detection of Pharmaceutical and Personal ...nemc.us/docs/2013/presentations/Thu-Topics in Drinking Water-23.6... · 2,4-D pesticide/herbicide Ametryn pesticide/herbicide

Copyright 2012 Bruker Corporation. All Rights Reserved.

C h e m i c a l a n d A p p l i e d M a r k e t s

Conclusion

GC-TQ or LC-TQ MRM Data Reports

Data Generation Information Creation Decisions

Game-Changing Products for Quadrupole MS Applications