UK Practice for the Electrodiagnosis of MND

Results

Mark Baker

Stephan Jaiser

Page 2: UK Practice for the Electrodiagnosis of MND · Electrodiagnosis of MND Results Mark Baker Stephan Jaiser. Design •Form A •Practice parameters for individual doctors •One per

Design

• Form A• Practice parameters for individual doctors

• One per doctor, potentially multiple per centre

• Form B• Individual clinical cases

Page 3: UK Practice for the Electrodiagnosis of MND · Electrodiagnosis of MND Results Mark Baker Stephan Jaiser. Design •Form A •Practice parameters for individual doctors •One per

Form AIndividual Practice

Page 4: UK Practice for the Electrodiagnosis of MND · Electrodiagnosis of MND Results Mark Baker Stephan Jaiser. Design •Form A •Practice parameters for individual doctors •One per
Page 5: UK Practice for the Electrodiagnosis of MND · Electrodiagnosis of MND Results Mark Baker Stephan Jaiser. Design •Form A •Practice parameters for individual doctors •One per
Page 6: UK Practice for the Electrodiagnosis of MND · Electrodiagnosis of MND Results Mark Baker Stephan Jaiser. Design •Form A •Practice parameters for individual doctors •One per

General

• Number of doctors 45

• Number of centres 28

0

5

10

15

20

1 2 3 4 5 6

Nu

mb

er o

f ce

ntr

es

Number of responses per centre

Page 7: UK Practice for the Electrodiagnosis of MND · Electrodiagnosis of MND Results Mark Baker Stephan Jaiser. Design •Form A •Practice parameters for individual doctors •One per

Number of referrals

0

5

10

15

Nu

mb

er

of

resp

on

ses

Number of referrals

Page 8: UK Practice for the Electrodiagnosis of MND · Electrodiagnosis of MND Results Mark Baker Stephan Jaiser. Design •Form A •Practice parameters for individual doctors •One per

Number of referrals

• Centres with multiple responses

Responses per centre Number of referrals

2 10-120

2 30

2 30

2 36-75

2 40-45

3 96

3 170-350

6 30

Page 9: UK Practice for the Electrodiagnosis of MND · Electrodiagnosis of MND Results Mark Baker Stephan Jaiser. Design •Form A •Practice parameters for individual doctors •One per

Appointment length

0

5

10

15

30 35 40 45 50 55 60 65 70 75 80 85 90

Nu

mb

er

of

resp

on

ses

Appointment length (min)

Page 10: UK Practice for the Electrodiagnosis of MND · Electrodiagnosis of MND Results Mark Baker Stephan Jaiser. Design •Form A •Practice parameters for individual doctors •One per

Appointment length

• Centres with multiple responses

Responses per centre Appointment length (min)

2 30

2 30-45

2 40-60

2 80-90

2 90

3 40-45

3 45

6 30-45

Page 11: UK Practice for the Electrodiagnosis of MND · Electrodiagnosis of MND Results Mark Baker Stephan Jaiser. Design •Form A •Practice parameters for individual doctors •One per

Guidelines

• In use?

• Which ones?

0

5

10

15

20

25

Yes No

Nu

mb

er o

f ce

ntr

es

0

5

10

15

Awaji Revised El Escorial El Escorial El Escorial/Awaji Revised ElEscorial/Awaji

Other

Nu

mb

er o

f ce

ntr

es

Page 12: UK Practice for the Electrodiagnosis of MND · Electrodiagnosis of MND Results Mark Baker Stephan Jaiser. Design •Form A •Practice parameters for individual doctors •One per

Local protocol

0

5

10

15

20

25

30

Yes No

Nu

mb

er o

f ce

ntr

es

Page 13: UK Practice for the Electrodiagnosis of MND · Electrodiagnosis of MND Results Mark Baker Stephan Jaiser. Design •Form A •Practice parameters for individual doctors •One per

Local audit

0

5

10

15

20

25

0 1 2 3

Nu

mb

er o

f ce

ntr

es

Number of audits per centre

Page 14: UK Practice for the Electrodiagnosis of MND · Electrodiagnosis of MND Results Mark Baker Stephan Jaiser. Design •Form A •Practice parameters for individual doctors •One per

EMG study

• Four regions studied?

0

5

10

15

20

25

30

35

Yes 3 or 4 No

Nu

mb

er o

f re

spo

nse

s

Page 15: UK Practice for the Electrodiagnosis of MND · Electrodiagnosis of MND Results Mark Baker Stephan Jaiser. Design •Form A •Practice parameters for individual doctors •One per

EMG study

• Two muscles per region?

0

5

10

15

20

25

30

35

Yes One in bulbar and thoracic One in thoracic One in bulbar No

Nu

mb

er o

f re

spo

nse

s

Page 16: UK Practice for the Electrodiagnosis of MND · Electrodiagnosis of MND Results Mark Baker Stephan Jaiser. Design •Form A •Practice parameters for individual doctors •One per

EMG study

• One or two sides?

0

5

10

15

20

One side Two sides Depends No or conflicting data

Nu

mb

er o

f re

spo

nse

s

Page 17: UK Practice for the Electrodiagnosis of MND · Electrodiagnosis of MND Results Mark Baker Stephan Jaiser. Design •Form A •Practice parameters for individual doctors •One per

EMG study vs appointment length

0

2

4

6

8

10

12

30 35 40 45 50 55 60 65 70 75 80 85 90

Nu

mb

er

of

resp

on

ses

Appointment length (min)

4 regions - yes

4 regions - no

0

2

4

6

8

10

12

30 35 40 45 50 55 60 65 70 75 80 85 90

Nu

mb

er

of

resp

on

ses

Appointment length (min)

2 muscles - yes

2 muscles - no

p=0.63 (Mann-Whitney U)

p=0.45 (Mann-Whitney U)

• Four regions studied?

• Two muscles per region?

Page 18: UK Practice for the Electrodiagnosis of MND · Electrodiagnosis of MND Results Mark Baker Stephan Jaiser. Design •Form A •Practice parameters for individual doctors •One per

EMG study

• Muscles – bulbar

0

5

10

15

20

25

30

35

40

45

Tongue Trapezius SCM Masseter Orbicularis oris Mentalis Orbicularis oculi Frontalis

Page 19: UK Practice for the Electrodiagnosis of MND · Electrodiagnosis of MND Results Mark Baker Stephan Jaiser. Design •Form A •Practice parameters for individual doctors •One per

EMG study

• Muscles – cervical

0

5

10

15

20

25

30

35

40

45

Page 20: UK Practice for the Electrodiagnosis of MND · Electrodiagnosis of MND Results Mark Baker Stephan Jaiser. Design •Form A •Practice parameters for individual doctors •One per

EMG study

• Muscles – thoracic

0

5

10

15

20

25

30

35

40

Paraspinals Rectus abdominis Erector spinae External oblique Pectoralis Not done

Page 21: UK Practice for the Electrodiagnosis of MND · Electrodiagnosis of MND Results Mark Baker Stephan Jaiser. Design •Form A •Practice parameters for individual doctors •One per

EMG study

• Muscles – lumbosacral

0

10

20

30

40

50

60

Quadriceps TA Gastrocnemius Paraspinals Iliopsoas FHB TFL AH

Page 22: UK Practice for the Electrodiagnosis of MND · Electrodiagnosis of MND Results Mark Baker Stephan Jaiser. Design •Form A •Practice parameters for individual doctors •One per

EMG on anticoagulation

0

5

10

15

20

25

30

Yes No Discussion ofrisks/limited

INR NOS INR<3/discussion INR<2.5/discussion No data

Nu

mb

er o

f re

spo

nse

s

• Warfarin

Page 23: UK Practice for the Electrodiagnosis of MND · Electrodiagnosis of MND Results Mark Baker Stephan Jaiser. Design •Form A •Practice parameters for individual doctors •One per

EMG on anticoagulation

0

5

10

15

20

25

30

35

40

Yes No Caution/caveats Stop>24h No data

Nu

mb

er o

f re

spo

nse

s

• NOACs

Page 24: UK Practice for the Electrodiagnosis of MND · Electrodiagnosis of MND Results Mark Baker Stephan Jaiser. Design •Form A •Practice parameters for individual doctors •One per

Other tests

• NCS

0

5

10

15

20

25

30

35

40

45

Yes If clinical suspicion If requested If clinical suspicion orrequested

No No data

Nu

mb

er o

f re

spo

nse

s

Page 25: UK Practice for the Electrodiagnosis of MND · Electrodiagnosis of MND Results Mark Baker Stephan Jaiser. Design •Form A •Practice parameters for individual doctors •One per

Other tests

• Segmental/proximal studies

0

5

10

15

20

Yes If clinical suspicion If requested If clinical suspicion orrequested

No No data

Nu

mb

er o

f re

spo

nse

s

Page 26: UK Practice for the Electrodiagnosis of MND · Electrodiagnosis of MND Results Mark Baker Stephan Jaiser. Design •Form A •Practice parameters for individual doctors •One per

Other tests

• Repetitive nerve stimulation

0

5

10

15

20

Yes If clinical suspicion If requested If clinical suspicion orrequested

No No data

Nu

mb

er o

f re

spo

nse

s

Page 27: UK Practice for the Electrodiagnosis of MND · Electrodiagnosis of MND Results Mark Baker Stephan Jaiser. Design •Form A •Practice parameters for individual doctors •One per

Other tests

• MUNE

0

5

10

15

20

25

30

35

40

45

Yes If clinical suspicion If requested If clinical suspicion orrequested

No No data

Nu

mb

er o

f re

spo

nse

s

Page 28: UK Practice for the Electrodiagnosis of MND · Electrodiagnosis of MND Results Mark Baker Stephan Jaiser. Design •Form A •Practice parameters for individual doctors •One per

Other tests

• TMS

0

5

10

15

20

25

30

35

40

Yes If clinical suspicion If requested If clinical suspicion orrequested

No No data

Nu

mb

er o

f re

spo

nse

s

Page 29: UK Practice for the Electrodiagnosis of MND · Electrodiagnosis of MND Results Mark Baker Stephan Jaiser. Design •Form A •Practice parameters for individual doctors •One per

Other tests

• Other• Turns/amplitude and MUP 1

• USS for fascics/MMN 2

Page 30: UK Practice for the Electrodiagnosis of MND · Electrodiagnosis of MND Results Mark Baker Stephan Jaiser. Design •Form A •Practice parameters for individual doctors •One per

Form BIndividual Referrals

Page 31: UK Practice for the Electrodiagnosis of MND · Electrodiagnosis of MND Results Mark Baker Stephan Jaiser. Design •Form A •Practice parameters for individual doctors •One per
Page 32: UK Practice for the Electrodiagnosis of MND · Electrodiagnosis of MND Results Mark Baker Stephan Jaiser. Design •Form A •Practice parameters for individual doctors •One per

General

• Number of centres 31

• Time from referral (days)• Range 0-150

• Mean 23.2

• Median 20

Page 33: UK Practice for the Electrodiagnosis of MND · Electrodiagnosis of MND Results Mark Baker Stephan Jaiser. Design •Form A •Practice parameters for individual doctors •One per

Referring speciality

0

20

40

60

80

100

120

140

160

180

Page 34: UK Practice for the Electrodiagnosis of MND · Electrodiagnosis of MND Results Mark Baker Stephan Jaiser. Design •Form A •Practice parameters for individual doctors •One per

Referral indication

0

20

40

60

80

100

120

140

160

180

200

ALS/MND/AHCD/PMS/etc Other

Page 35: UK Practice for the Electrodiagnosis of MND · Electrodiagnosis of MND Results Mark Baker Stephan Jaiser. Design •Form A •Practice parameters for individual doctors •One per

Diagnosis made

0

20

40

60

80

100

120

ALS/MND/AHCD/PMS/etc Other

Page 36: UK Practice for the Electrodiagnosis of MND · Electrodiagnosis of MND Results Mark Baker Stephan Jaiser. Design •Form A •Practice parameters for individual doctors •One per

Accuracy of initial clinical diagnosis

0%

10%

20%

30%

40%

50%

60%

164 18 8 2 21 1 1 1 1 1n

Page 37: UK Practice for the Electrodiagnosis of MND · Electrodiagnosis of MND Results Mark Baker Stephan Jaiser. Design •Form A •Practice parameters for individual doctors •One per

Repeat EMG recommended

• 26%

• Example reasons• “Assess progression”

• “If clinical deterioration”

• For alternative test e.g. sfEMG

Page 38: UK Practice for the Electrodiagnosis of MND · Electrodiagnosis of MND Results Mark Baker Stephan Jaiser. Design •Form A •Practice parameters for individual doctors •One per

Comments

Page 39: UK Practice for the Electrodiagnosis of MND · Electrodiagnosis of MND Results Mark Baker Stephan Jaiser. Design •Form A •Practice parameters for individual doctors •One per

Variation in practice across UK

• Appointment length for EMG for ?MND

• EMG on anticoagulation

Page 40: UK Practice for the Electrodiagnosis of MND · Electrodiagnosis of MND Results Mark Baker Stephan Jaiser. Design •Form A •Practice parameters for individual doctors •One per

Appointment length

• What factors determine appointment length?• Number of muscles sampled? – No.

• Local protocols? – No.

• Published guidelines?

• Survey of UK practice?• Justification for appointment length for ?MND

• Do we need a national standard?

Page 41: UK Practice for the Electrodiagnosis of MND · Electrodiagnosis of MND Results Mark Baker Stephan Jaiser. Design •Form A •Practice parameters for individual doctors •One per

EMG on anticoagulation

• Review of evidence• E.g. Dodd et al.

• Survey of UK practice?

• Focus on NOACs?

• Rolling database?

Page 42: UK Practice for the Electrodiagnosis of MND · Electrodiagnosis of MND Results Mark Baker Stephan Jaiser. Design •Form A •Practice parameters for individual doctors •One per

UK Practice for the Electrodiagnosis of MND

Results

Mark Baker

Stephan Jaiser