www.tridonic.com 1 Subject to change without notice. Data sheet 10/14-LED101-6 LED light engine / OLED LED compact Product description • Ideal for ceiling-mounted and wallmounted luminaires • LED system solution consisting of the LED module, the control gear with integrated emergency function and SWITCH sensor • Based on circular and TC-DD fluorescent lamps Efficacy of the module up to 136 lm/W • SO version is compatible with SWITCH Sensor HF 5BP – Simple CORRIDOR FUNCTION in combination with EMpowerLED 15 W • Integrated separate emergency LEDs controlled by EM powerLED • High colour rendering index CRI > 80 • Small colour tolerance MacAdam 3 1 • Small luminous flux tolerances • Colour temperatures 3,000 and 4,000 K • Self-cooling (no additional heat sink required) • Push terminals for quick and simple wiring • Simple installation (e.g. screws) • Long life-time: 50,000 hours • 5-year system guarantee on the complete product Technical data Beam characteristic 120° Ambient temperature ta -30 ... +45 °C Typ. tp point 65 °C Risk group (EN 62471:2008) 0 Type of protection IP00 È Standards, page 5 For colour temperatures and tolerances, page 9 Umodule STARK CLE 220-1500 CLASSIC EM STARK CLE STARK-CLE-220-1500-EM STARK-CLE-220-1500-EM-SO Ø4,2 Ø4,2 40,25 62,5 85 65,38 tp Ø220 124 62 STARK-CLE-220-1500-EM 193,5 191 tp 85 60 85 69 Ø4 Ø220 STARK-CLE-220-1500-EM-SO Ordering data Type Article number Colour temperature Packaging, carton Weight per pc. STARK-CLE-220-1500-830-CLA-EM 28000106 3,000 K 160 pc(s). 0.060 kg STARK-CLE-220-1500-840-CLA-EM 28000107 4,000 K 160 pc(s). 0.060 kg STARK-CLE-220-1500-830-CLA-EM-SO 28000108 3,000 K 160 pc(s). 0.055 kg STARK-CLE-220-1500-840-CLA-EM-SO 28000109 4,000 K 160 pc(s). 0.054 kg PHASED OUT

Upload: others

Post on 04-Feb-2021

5 views

Category:

Documents


0 download

TRANSCRIPT

  • www.tridonic.com 1Subject to change without notice.Data sheet 10/14-LED101-6

    LED light engine / OLEDLED compact

    Product description

    • Ideal for ceiling-mounted and wallmounted luminaires

    • LED system solution consisting of the LED module, the control gear

    with integrated emergency function and SWITCH sensor

    • Based on circular and TC-DD fluorescent lamps

    • Efficacy of the module up to 136 lm/W

    • SO version is compatible with SWITCH Sensor HF 5BP – Simple

    CORRIDOR FUNCTION in combination with EMpowerLED 15 W

    • Integrated separate emergency LEDs controlled by

    EM powerLED

    • High colour rendering index CRI > 80

    • Small colour tolerance MacAdam 31

    • Small luminous flux tolerances

    • Colour temperatures 3,000 and 4,000 K

    • Self-cooling (no additional heat sink required)

    • Push terminals for quick and simple wiring

    • Simple installation (e.g. screws)

    • Long life-time: 50,000 hours

    • 5-year system guarantee on the complete product

    Technical dataBeam characteristic 120°

    Ambient temperature ta -30 ... +45 °C

    Typ. tp point 65 °C

    Risk group (EN 62471:2008) 0

    Type of protection IP00

    ÈStandards, page 5

    For colour temperatures and tolerances, page 9

    Umodule STARK CLE 220-1500 CLASSIC EMSTARK CLE

    STARK-CLE-220-1500-EM STARK-CLE-220-1500-EM-SO

    Ø4,2

    Ø8

    40,2

    5

    24,2575,50

    65,3

    8

    tp

    Ø130

    124

    62

    Ø4,2

    40,2

    5

    62,585

    65,3

    8

    tp

    Ø220

    124

    62

    D

    STARK-CLE-220-1500-EM

    193,5

    191

    tp

    8560

    8569

    In(+)

    Out(-)

    EM_In(+)

    EM_Out(-)TP(-)

    TP(+)

    EM_TP(-)

    EM_TP(+)

    -+

    -+

    - +

    -+

    -+

    -+

    -+

    -+

    -+

    -+

    -+

    -+

    -+

    -+

    -+

    -+

    -+

    -+

    -+

    -+

    -+

    - +

    - +

    -+

    -+

    -+

    -+

    -+

    -+

    -+

    -+

    -+

    -+

    -+

    16

    15

    14

    13

    12

    11

    10

    9

    8

    7

    6

    5

    4

    3

    2

    1

    20

    19

    18

    17

    33

    26

    23

    24

    25

    27

    28

    29

    30

    31

    32

    34

    21

    22

    TALEX moduleSTARK-CLE-220-1500-830-CLA-EM-CO Art. No. 28000108

    Typ. If=350mA (Uf=~32V)

    Ø4

    Ø220

    STARK-CLE-220-1500-EM-SO

    Ordering data

    Type Article number Colour temperature

    Packaging,carton

    Weightper pc.

    STARK-CLE-220-1500-830-CLA-EM 28000106 3,000 K 160 pc(s). 0.060 kg

    STARK-CLE-220-1500-840-CLA-EM 28000107 4,000 K 160 pc(s). 0.060 kg

    STARK-CLE-220-1500-830-CLA-EM-SO 28000108 3,000 K 160 pc(s). 0.055 kg

    STARK-CLE-220-1500-840-CLA-EM-SO 28000109 4,000 K 160 pc(s). 0.054 kgPHAS

    ED O

    UT

  • www.tridonic.com 2Subject to change without notice.Data sheet 10/14-LED101-6

    LED light engine / OLEDLED compact

    Specific technical dataType5 Photo-

    metric code

    Typ. luminous flux at

    tp 25 °C2

    Typ. luminous flux at

    tp 65 °C2

    Typ. forward current2 3 4

    Typ. forward voltage

    Typ. power consumption2

    Luminous efficacy module

    at tp 25 °C

    Luminous efficacy module

    at tp 65 °C

    Luminous efficacy system

    at tp 65 °C

    Colour rendering index CRI

    Energy clas-sification

    Operating mode HE at 350 mASTARK-CLE-220-1500-830-CLA EM 830/3x9 1,350 lm 1,300 lm 350 mA 29.5 V 10.3 W ~ 131 lm/W ~ 126 lm/W ~ 107 lm/W > 80 A+

    STARK-CLE-220-1500-840-CLA EM 840/3x9 1,400 lm 1,350 lm 350 mA 29.5 V 10.3 W ~ 136 lm/W ~ 131 lm/W ~ 111 lm/W > 80 A+

    STARK-CLE-220-1500-830-CLA EM-SO 830/3x9 1,350 lm 1,300 lm 350 mA 29.5 V 10.3 W ~ 131 lm/W ~ 126 lm/W ~ 107 lm/W > 80 A+

    STARK-CLE-220-1500-840-CLA EM-SO 840/3x9 1,400 lm 1,350 lm 350 mA 29.5 V 10.3 W ~ 136 lm/W ~ 131 lm/W ~ 111 lm/W > 80 A+

    Operating mode HO at 470 mASTARK-CLE-220-1500-830-CLA EM 830/3x9 1,750 lm 1,650 lm 470 mA 30.5 V 14.3 W ~ 122 lm/W ~ 115 lm/W ~ 98 lm/W > 80 A+

    STARK-CLE-220-1500-840-CLA EM 840/3x9 1,800 lm 1,700 lm 470 mA 30.5 V 14.3 W ~ 126 lm/W ~ 119 lm/W ~ 101 lm/W > 80 A+

    STARK-CLE-220-1500-830-CLA EM-SO 830/3x9 1,750 lm 1,650 lm 470 mA 30.5 V 14.3 W ~ 122 lm/W ~ 115 lm/W ~ 98 lm/W > 80 A+

    STARK-CLE-220-1500-840-CLA EM-SO 840/3x9 1,800 lm 1,700 lm 470 mA 30.5 V 14.3 W ~ 126 lm/W ~ 119 lm/W ~ 101 lm/W > 80 A+

    Operating mode HO at 500 mASTARK-CLE-220-1500-830-CLA EM 830/3x9 1,800 lm 1,750 lm 500 mA 30.5 V 15.3 W ~ 118 lm/W ~ 114 lm/W ~ 97 lm/W > 80 A+

    STARK-CLE-220-1500-840-CLA EM 840/3x9 1,900 lm 1,800 lm 500 mA 30.5 V 15.3 W ~ 124 lm/W ~ 118 lm/W ~ 100 lm/W > 80 A+

    STARK-CLE-220-1500-830-CLA EM-SO 830/3x9 1,800 lm 1,750 lm 500 mA 30.5 V 15.3 W ~ 118 lm/W ~ 114 lm/W ~ 97 lm/W > 80 A+

    STARK-CLE-220-1500-840-CLA EM-SO 840/3x9 1,900 lm 1,800 lm 500 mA 30.5 V 15.3 W ~ 124 lm/W ~ 118 lm/W ~ 100 lm/W > 80 A+

    Emergency mode at 320 mA (EM powerLED NM 1 W BASIC, EM powerLED 15 W BASIC CLE NiCd)STARK-CLE-220-1500-830-CLA EM 830/3x9 125 lm 120 lm 320 mA 2.95 V – – – – – –

    STARK-CLE-220-1500-840-CLA EM 840/3x9 130 lm 125 lm 320 mA 2.95 V – – – – – –

    STARK-CLE-220-1500-830-CLA EM-SO 830/3x9 125 lm 120 lm 320 mA 2.95 V – – – – – –

    STARK-CLE-220-1500-840-CLA EM-SO 840/3x9 130 lm 125 lm 320 mA 2.95 V – – – – – –

    Emergency mode at 350 mA (EM powerLED 1 W)STARK-CLE-220-1500-830-CLA EM 830/3x9 135 lm 130 lm 350 mA 2.95 V – – – – – –

    STARK-CLE-220-1500-840-CLA EM 840/3x9 140 lm 135 lm 350 mA 2.95 V – – – – – –

    STARK-CLE-220-1500-830-CLA EM-SO 830/3x9 135 lm 130 lm 350 mA 2.95 V – – – – – –

    STARK-CLE-220-1500-840-CLA EM-SO 840/3x9 140 lm 135 lm 350 mA 2.95 V – – – – – –

    Emergency mode at 400 mA (EM powerLED 15 W BASIC CLE NiMH)STARK-CLE-220-1500-830-CLA EM 830/3x9 150 lm 145 lm 400 mA 3.0 V – – – – – –

    STARK-CLE-220-1500-840-CLA EM 840/3x9 160 lm 150 lm 400 mA 3.0 V – – – – – –

    STARK-CLE-220-1500-830-CLA EM-SO 830/3x9 150 lm 145 lm 400 mA 3.0 V – – – – – –

    STARK-CLE-220-1500-840-CLA EM-SO 840/3x9 160 lm 150 lm 400 mA 3.0 V – – – – – –

    Emergency mode at 600 mA (EM powerLED 2 W)STARK-CLE-220-1500-830-CLA EM 830/3x9 220 lm 210 lm 600 mA 3.1 V – – – – – –

    STARK-CLE-220-1500-840-CLA EM 840/3x9 230 lm 220 lm 600 mA 3.1 V – – – – – –

    STARK-CLE-220-1500-830-CLA EM-SO 830/3x9 220 lm 210 lm 600 mA 3.1 V – – – – – –

    STARK-CLE-220-1500-840-CLA EM-SO 840/3x9 230 lm 220 lm 600 mA 3.1 V – – – – – –1 Integrated measurement over the whole module.

    2 Tolerance range for optical and electrical data: ±10 %.

    3 Max. permissible repetitive peak current: 720 mA

    4 Max. permissible surge current: 1.5 A, duration max. 10 µs.

    5 HE ... high efficiency, Ho ... high output.

    SWITCH Sensor HF 5BPAutomatic switching based on motion and light level

    ACCE

    S-SO

    RIES

    76,5

    58 32

    8367

    Ordering dataType Article number Packaging, carton Weight per pcs.

    SWITCH Sensor HF 5BP 28000086 4 pieces 0,078 kg

    PHAS

    ED O

    UT

  • www.tridonic.com 3Subject to change without notice.Data sheet 10/14-LED101-6

    LED light engine / OLEDLED compact

    SWITCH Sensor HF 5BPAutomatic switching based on motion and light level

    ACCE

    S-SO

    RIES

    76,5

    58 32

    8367

    Ordering dataType Article number Packaging, carton Weight per pcs.

    SWITCH Sensor HF 5BP 28000086 4 pieces 0,078 kg

    Product description

    • Motion detector for luminaire installation

    • Motion detection through glass and thin materials (except metal)

    • For automatic on/off switching of electronic ballasts with corridor-

    FUNCTION

    • “Bright-Out” function: luminaire is not switched on if there is

    adequate brightness

    • Delay time, detection range and light value for the “Bright-Out”

    function can be set via 3 potentiometers

    • Max. installation height 5 m

    • Infinitely variable range (0.5 – 5.0 m)

    Technical dataRated supply voltage 230 – 240 V

    Mains frequency 50 Hz

    Power < 0.5 W

    Ambient temperature ta -20 ... +75 °C

    Storage temperature ts -20 ... +75 °C

    Humidity min. 5 % ... max. 85 % at 30 °C

    Type of protection IP20

    Casing material PC, halogen-free

    Casing colour RAL 9016

    Specific technical dataType

    Dimensions LxWxHDetection Output, relay (L‘)

    Detection angle Transmission power Frequency L‘ (switched line)

    SWITCH Sensor HF 5BP 83x58x32 mm 160° 1 mW 5.8 GHz 230 – 240 V

    PHAS

    ED O

    UT

  • www.tridonic.com 4Subject to change without notice.Data sheet 10/14-LED101-6

    LED light engine / OLEDLED compact

    For umodule STARK CLE a tp temperature of 65 °C has to be complied in order to achieve an optimum between light output and life-time.

    Compliance with the maximum permissible reference temperature at the tp point must be checked under operating conditions in a thermally stable state. The maximum value must be determined under worst-case conditions for the relevant application.

    The tc and tp temperature of LED modules from Tridonic are measured at the same reference point.

    Mounting instruction

    None of the components of the umodule STARK CLE (substrate, LED, electronic components etc.) may be exposed to tensile or compressive stresses.

    Max. torque for fixing: 0.5 Nm.

    The LED modules are mounted with 4 screws per module.In order not to damage the modules only rounded head screws and anadditional plastic flat washer should be used.

    Thermal design and heat sinkThe rated life of u products depends to a large extent on the temperature. If the permissible temperature limits are exceeded, the life of the umodule STARK CLE will be greatly reduced or the umodule STARK CLE may be destroyed.

    tp point, ambient temperature and life-timeThe temperature at tp reference point is crucial for the light output and life-time of a u product.

    StandardsEN 62031EN 62471EN 61347-1EN 61547EN 55015

    1st digit 2nd + 3rd digit 4th digit 5th digit 6th digit

    Code CRIColour temperature in

    Kelvin x 100McAdams

    initial

    McAdams after 25% of the

    life-time (max. 6,000h)

    Lumen maintanance after 25% of the life-time (max.6000h)

    Code Remaining lumen7 67 – 76 7 ≥ 70 %8 77 – 86 8 ≥ 80 %9 87 – ≥90 9 ≥ 90 %

    Photometric code

    Key for photometric code, e. g. 830 / 449

    EOS/ESD safety guidelines

    The device / module contains components that are sensitive to electro-static discharge and may only be installed in the factory and on site if appropriate EOS/ESD protection measures have been taken. No special measures need be taken for devices/modules with enclosed casings (contact with the pc board not possible), just normal installation prac-tice. Please note the requirements set out in the document EOS / ESD guidelines (Guideline_EOS_ESD.pdf) at: http://www.tridonic.com/esd-protection

    Chemical substance may harm the LED module. Chemical reactions could lead to colour shift, reduced luminous flux or a total failure of the module caused by corrosion of electrical connections.

    Materials which are used in LED applications (e.g. sealings, adhesives) must not produce dissolver gas. They must not be condensation curing based, acetate curing based or contain sulfur, chlorine or phthalate.Avoid corrosive atmosphere during usage and storage.

    PHAS

    ED O

    UT

  • www.tridonic.com 5Subject to change without notice.Data sheet 10/14-LED101-6

    LED light engine / OLEDLED compact

    Electrical supply/choice of LED control gearumodule STARK CLE from Tridonic are not protected against overvoltages, overcurrents, overloads or short-circuit currents. Safe and reliable operation can only be guaranteed in conjunction with a LED control gear which complies with the relevant standards. The use of uconverter from Tridonic in combination with umodule STARK CLE guarantees the necessary protection for safe and reliable operation.

    If a LED control gear other than Tridonic uconverter is used, it must provide the following protection:• Short-circuit protection• Overload protection• Overtemperature protection

    umodule STARK CLE must be supplied by a constant current LED control gear.Operation with a constant voltage LED control gear will lead to an irrevers-ible damage of the module.

    Wrong polarity can damage the umodule STARK CLE.

    tp temperature in °C IF luminous flux in % life-time in h

    65 350 mA80 40,00070 70,00050 140,000

    Life-time

    Thermal behaviour

    storage temperature -40 ... +85 °Coperating temperature ta -30 ... +45 °Ctp max. (at typ. current) 85 °Cmax. humidity 0 ... 80 %

    Wiring type and cross sectionThe wiring can be solid cable with a cross section of 0.4 to 0.75 mm². For the push-wire connection you have to strip the insulation (6–7 mm).Loosen wire through twisting and pulling.

    6 – 7 mm

    wire preparation:0.4 – 0.75 mm²

    Release of the wiringPress down the “push button” and remove the cable from front.

    0

    100

    200

    300

    400

    500

    600

    0 10 20 30 40 50 60 70 80 90 100tp [°C]

    If [m

    A]

    25 35 45 55 65 75 85tp temperature [°C]

    Life

    time

    [h] L

    70

    30000

    40000

    50000

    60000

    70000

    80000

    90000

    100000

    110000

    120000

    130000350 mA

    500 mA

    0 20000 40000 60000 80000 10000050

    60

    70

    80

    90

    100

    110

    Lifetime [h] at tp = 65 °C

    Ligh

    t out

    put [

    %]

    350 mA

    500 mAPHAS

    ED O

    UT

  • www.tridonic.com 6Subject to change without notice.Data sheet 10/14-LED101-6

    LED light engine / OLEDLED compact

    Wiring

    out (–)

    in (+) EM_in (+)

    EM_out (–)

    UmodulesSTARK CLE EM

    LN

    230 – 240 V AC50/60 Hz

    UconverterLCCI 16 W 350 mA

    EM PowerLED 2W

    Permanentline

    PE

    +–

    Akku

    +–

    Wiring examples

    EM powerLED 15 W BASIC CLE

    220–240 V

    LN

    50/60 Hz

    L

    N

    LEDMaintained

    LEDEmergency

    EMEM

    +-

    +-

    +-

    +-

    Battery

    Indication LED

    +-

    OP

    PIR input

    Tridonic Sensor

    Tridonic STARK CLE

    LN

    ��

    SL

    CF

    PHAS

    ED O

    UT

  • www.tridonic.com 7Subject to change without notice.Data sheet 10/14-LED101-6

    LED light engine / OLEDLED compact

    Optical characteristics Umodule STARK CLE

    The optical design of the umodule STARK CLE product line ensures optimumhomogenity for the light distribution.

    Light distribution

    20

    20

    -20 40

    40

    60

    60

    80

    100

    80 100-40-60-80-100

    10°-10°20°-20°

    -30°

    -40°

    -50°

    -60°

    30°

    40°

    50°

    60°

    70°

    80°

    90°00

    rela

    tive

    inte

    nsity

    Iv/Iv

    , max

    The diagrams based on statistic values.The real values can be different.

    Relative luminous flux

    Relative luminous flux vs. operating current

    rel.

    lum

    inou

    s flu

    x [%

    ]re

    l. lu

    min

    ous

    flux

    [%]

    The colour temperature is measured integral over the complete module. The single LED light points can have deviations in the colour coordinates within MacAdam 7. To ensure an ideal mixture of colours and a homogenious light distribution a suitable optic (e. g. PMMA diffuser) and a sufficient spacing between module and optic (typ. 5 cm) should be used.

    35 45 55 65tp [°C]

    25 75 8570

    80

    90

    110

    100

    50 100 150 200 250 300Operating current [mA]

    0 350 400 450 5000

    25

    50

    75

    125

    150

    100

    For further information see Design-in Guide, 3D data and photometric data on www.tridonic.com or on request.

    PHAS

    ED O

    UT

  • www.tridonic.com 8Subject to change without notice.Data sheet 10/14-LED101-6

    LED light engine / OLEDLED compact

    Coordinates and tolerances according to CIE 1931

    The specified colour coordinates are measured by a current impulse with typical values of module and a duration of 100 ms.The ambient temperature of the measurement is ta = 25 °C.The measurement tolerance of the colour coordinates are ± 0.01.

    3,000 Kx0 y0

    Centre 0.4344 0.4032

    380 420 460 500 540 580 620 660 700 740 780wave length [nm]

    norm

    . int

    ensi

    ty [%

    ]0

    20

    40

    60

    80

    100

    380 420 460 500 540 580 620 660 700 740 780wave length [nm]

    norm

    . int

    ensi

    ty [%

    ]

    0

    20

    40

    60

    80

    100

    4,000 Kx0 y0

    Centre 0.3828 0.3803

    MacAdam Ellipse: 3SDCM

    MacAdam Ellipse: 3SDCM

    0,3600

    0,3650

    0,3700

    0,3750

    0,3800

    0,3850

    0,3900

    0,3950

    0,4000

    0,36

    00

    0,36

    50

    0,37

    00

    0,37

    50

    0,38

    00

    0,38

    50

    0,39

    00

    0,39

    50

    0,40

    00

    0,3850

    0,3900

    0,3950

    0,4000

    0,4050

    0,4100

    0,4150

    0,4200

    0,4250

    0,41

    50

    0,42

    00

    0,42

    50

    0,43

    00

    0,43

    50

    0,44

    00

    0,44

    50

    0,45

    00

    0,45

    50

    PHAS