typicalbeverageplantdisinfeconuses...carbonated soft drink plant, 4 bottling/ canning lines ! 4...

8
Boiler & Clean Steam Feed Water Incoming Process Water Cooling Tower Disinfection Reclaimed Water Wastewater Treatment Clean-in-Place Product Water Purification Bottle Washing Typical Beverage Plant Disinfec4on Uses:

Upload: others

Post on 10-Jul-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Boiler & Clean Steam Feed Water

Incoming Process Water

Cooling Tower Disinfection

Reclaimed Water Wastewater

Treatment

Clean-in-Place

Product Water Purification

Bottle Washing

Typical  Beverage  Plant  Disinfec4on  Uses:  

}  Carbonated Soft Drink Plant, 4 bottling/canning lines

}  4 changeovers per day per line }  13 syrup and mixing tanks }  30 million cases per year

MIOX  Benefits:    }  Enhanced plant productivity: Estimated to

save 20 minutes per changeover or additional 320 min of total plant production per day: < 12 month payback

}  Environmental impact: reduction in the use and storage of toxic chemicals and reduced energy consumption

U.S.  Bo?ling  Plant  Installa4on  in  Texas  Integra4on  and  Process  Studies  with  MIOX  

MIOX  Vault  On-­‐site  Generator  (skid  mounted)  

(15  lbs  FAC)/day  

U.S.  Bo?ling  Plant  Installa4on  in  Texas  Integra4on  and  Process  Studies  with  MIOX  

}  Cleaning performance determined by - ◦  Visual inspection of CIP circuit ◦  Final rinse water tastes, odor, appearance (TOA)

�  in plant �  by corporate “professional tasters” �  both ECA and HOT CIP for comparison

◦  Rinse water micro plating }  Customer reported the following findings - ◦  No residual soils remain in syrup tanks or filler lines ◦  No residual TOA detected for validated systems by plant and by

professional panel ◦  No micro issues

U.S.  Bo?ling  Plant  Installa4on  in  Texas  Improvement  of  Opera4onal  Efficiencies  

3 Step Hot 3 step cold EO

2 step cold EO

Energy (MMBtu) 0.648018 0 0 Water (100 gal) 24.58 28.2 28.96 Time (min) 63.83 62 36.2

Chart Filler #3

}  Energy savings }  The cleaning time was

reduced in half

In  2  step  mid-­‐day  flavor  flush  the  customer  saved  approximately  1.5-­‐2  hrs  of  CIP  >me  that  can  be  turned  into  produc>on  

When switching from 3-step hot process to 2-step cold process test results from canning lines showed:

}  MIOX® RIO M2 Mixed Oxidant System installed in June 2010

}  MIOX systems used across various applications:

o  Clean-in-Place o  Dosed in potable water

treatment o  Wastewater o  Cooling towers o  External sanitation

}  45 CIP operations consecutive positive

}  Cost savings expected: $100,000/year over chemicals

Bo?ling  Plant  (Carbonated  Beverages)  Mexico  MOS  for  mul>-­‐point  beverage  applica>on  yields  significant  cost  savings  

}  MIOX® RIO M2 Mixed Oxidant }  Piloted May 2010 }  MOS utilized in the following applications

o  Clean-in-Place o  potable water treatment o  Wastewater o  External sanitation

}  Iron content reduced from 5 ppm to 0.01ppm

}  Positive flocculation results }  Cost savings expected: $150,000/year over

chemicals

Bo?ling  Plant  (Carbonated  Beverages)  Mexico  MOS  chosen  for  advanced  benefits,  biofilm  removal  

MIOX  Bo?ling  Plant  Installa4ons:  Mexico  

}  Three bottling facilities }  MOS utilized in the following applications

o  Cold Clean-in-Place o  Intake Water o  Wastewater Disinfection o  Cooling Towers

}  Purchase Drivers include: o  Less than a year payback based on

chemical usage o  Reduced water and energy usage o  Improved microbiological results o  Reduced CIP time by approximately

40% o  Meets environmental and

sustainability goals

}  Calcium hypochlorite replaced in 2007 with mixed oxidants solution (MOS) generated on site

}  Disinfectant is added to the source water, comprised of municipal water and a well site

}  MOS Disinfection is used in the following applications:

o  Beverages– Juice, Carbonated, Bottled water

o  Filter backwash o  Cooling towers

MIOX  Bo?ling  Plant  Installa4on:  Colombia  BEFORE MIOX

AFTER MIOX