turbo fan - teral.info
TRANSCRIPT
E-CAT-F-KT-01-B
Turbo Fan
Standard accessories
■Purpose- For ventilation of dryer, dust collector and selector, etc.- For cooling of equipment- For general blower
■Features1. A diverse lineup2. Realizes noise reduction by adoption of newly designed fans based on
fluid analysis technology3. Realizes high efficiency by adoption of newly designed fans based on
fluid analysis technology Achieves 86.5% of total voltage efficiency for 3.7kW products4. Capable of handling up to 150°C gas temperature for standard specifications (0.75kW and 1.5–3.7kW products)5. Capable of handling up to 250°C gas temperature for heat-resistant type6. Capable of handling outdoor specifications7. Capable of handling high static pressure and stainless welding gas portion (0.75kW and 1.5–3.7kW products)8. Capable of handling high efficiency and overseas regulations and responds to
various special motors of increased-safety and explosion-proof type, pressure-resistant and explosion-proof type, etc., by adoption of general-purpose motor. (0.75kW and 1.5–3.7kW products)
■Model description
KT - 020 T BH - R① ⑥④
④
⑤ ⑦③
KT - 5 370 T - TH - R① ⑥②
②
⑤ ⑦③
Suction phase flange
Discharge phase flange
Suction screen
Discharge screen
Suction damper
Standard Type
1
1
1
1
1
Items Heat-resistant Type
1
1
1
1
ー
Special accessories
Rubber vibration-proof mount, foundation bolt, expansion joint,
damper, silencer
■Standard specifications / special specifications / standard accessories / special accessories
Standard / special specifications
1) KT type (output: 0.1-0.4kW, 1.0kW)
● Standard spec. ◎ Special spec.
①Model, KT: Direct acting turbo fan, KTS: Direct acting stainless turbo fan②Frequency, type 5: 50Hz, 6:60Hz, B: high static pressure type (only 60Hz), No: double as 50Hz and 60Hz③Output, 010: 0.1kW, 020: 0.2kW, 040: 0.4kW, 075: 0.75kW, 100: 1.0kW, 150: 1.5kW, 220: 2.2kW, 370: 3.7kW④Power supply, S: single phase, T: three phases (No: three phases)⑤Handling gas temperature, No: standard type, T: heat-resistant type⑥Discharge direction, TH: top horizontal, TV: top vertical, BH: bottom horizontal⑦Rotation direction (from a motor), R: clockwise, L: counterclockwise
*1 In the case of inverter operation, the handling gas temperature is -10 to 40°C.*2 The heat-resistant type is in the special specifications.
*3 Accessory for only 010 and 020
Standard typeHeat-resistant type CasingImpellerImpeller bossStandard material
Discharge direction
Rotation direction
Conduction methodAmbient temperature
Handling gas temperature
Voltage
Materials
Coating
Discharge / rotation directions
Items●●●◎●◎●●●●●◎●●
SpecificationsEquipment specifications
Direct acting of motor−10~ 40°C−10~ 60°C *1
−10~ 250°C *1
200V(50Hz)/200V(60Hz)Different voltageADC12SECCFCD450Acrylic resin coating (silver color, except for motors)Bottom horizontalTop horizontal, top verticalR rotationL rotation
※Please note that the equipment in the photo represent examples and may differ slightly from actual equipment.
*3 *3
*2
Single suction direct acting type (horizontal motor)Turbo fan (backward curved vane blower)
Centrifugal Blower KTS TypeKT Type
2
Standard accessories
Suction phase flange
Discharge phase flange
Suction screen
Suction damper
Shaft seal
Standard type
1
1
1
1
1
Items Heat-resistant type
1
1
1
ー1
Special accessories
Rubber vibration-proof mount, foundation bolt, expansion joint,
damper, suction filter, silencer
Standard / Special Specifications
2) KT type (Output: 0.75kW, 1.5-3.7kW)
● Standard spec. ◎ Special spec.
Motor specificationsStandard (Made by Toshiba)Heat-resistant type (Made by Toshiba, dedicated heat-resistant specification)Specifications of Manufacturer other than ToshibaHigh efficiency typeIncreased-safety and explosion-proof typePressure-resistant and explosion proof type CasingImpellerImpeller bossStandard material
Discharge direction
Rotation direction
Conduction methodAmbient temperature
Handling gas
Voltage
Materials
Coating
Seal material
Discharge / rotation directions
Items●●
●◎◎◎◎◎●◎●●●●●●●◎●
SpecificationsEquipment specifications
Direct acting of motor−10~ 40°CTemperature−10~ 150°C *1
−10~ 250°C *1
−10~ 60°C *1
−10~ 60°C *1
−10~ 60°C *1
−10~ 60°C *1
200V(50Hz)/200-220V(60Hz)Different voltageAC4CSPCC、SECCFCD450Silicon resin coating (Silver color, except for motors)Sealing material, heat resistance 250°CPacking, heat resistance 250°CTop horizontal / top vertical / bottom horizontalAngle of 45 degrees (downward angle of 45 degrees is not available)L rotation / R rotation
*1 In the case of inverter operation, the handling gas temperature is -10 to 40°C.
Standard accessories
Suction phase flange
Discharge phase flange
Suction screen
Suction damper
Shaft seal
Standard type
ーーーー1
Items Heat-resistant type
ーーーー1
Special accessories
Rubber vibration-proof mount, foundation bolt, expansion joint,
damper, silencer
Standard / special specifications
3) KTS type, stainless welding gas portion
● Standard spec. ◎ Special spec.
Motor specificationsStandard (Made by Toshiba)Heat-resistant type (Made by Toshiba, dedicated heat-resistant specification)Specifications of Manufacturer other than ToshibaHigh efficiency typeIncreased-safety and explosion-proof typePressure-resistant and explosion proof type CasingImpellerImpeller bossStandard material
Discharge direction
Rotation direction
Conduction methodAmbient temperature
Handling gas
Voltage
Materials
Coating
Seal material
Discharge / rotation directions
Items●●
●◎◎◎◎◎●◎●●●●●●●◎●
SpecificationsEquipment specifications
Direct acting of motor−10~ 40°CTemperature−10~ 150°C *1
−10~ 250°C *1
−10~ 60°C *1
−10~ 60°C *1
−10~ 60°C *1
−10~ 60°C *1
200V(50Hz)/200-220V(60Hz)Different voltageSUS304SUS304SUS303Silicon resin coating (Silver color, except for motors)Sealing material, heat resistance 250°CPacking, heat resistance 250°CTop horizontal / top vertical / bottom horizontalAngle of 45 degrees (downward angle of 45 degrees is not available)L rotation / R rotation
*1 In the case of inverter operation, the handling gas temperature is -10 to 40°C.
Single suction direct acting type (horizontal motor)Turbo fan (backward curved vane blower)
Centrifugal BlowerKTS TypeKT Type
3
■Selection chart
1003 42 85 6 10 15 20 30 40 50 60 80
Sound level: Front of blower suction 1m
10.1
0.2
0.3
0.4
0.5
0.6
0.8
1.0
1.5
2.0
3.0
4.0
5.0
6.0
7.0
1003 42 85 6 10 15 20 30 40 50 60 8010.1
0.2
0.3
0.4
0.5
0.6
0.8
1.0
1.5
2.0
3.0
4.0
5.0
6.0
7.0
High static pressure
Standard
50Hz
60Hz
Air volume m3/min
87dB(A)
86
89
High static pressure 0.75kW High static pressure 2.2kWHigh static pressure 3.7kW
High static pressure 1.5kW
89dB(A)
89
92
79
81
83
82
78
81
77
75
71
72
65
81
80
77
70
66
60
63
0.1kW
0.2kW 0.4kW
0.75kW
1.5kW
2.2kW
3.7kW
1.0kW
63
79
680.1kW
0.2kW
0.4kW
1.0kW
1.5kW
2.2kW
3.7kW
0.75kW
85
88
8181
85
80
84
81
83
81
81
80
7775
76
74
76
68
65
66
68
72
69
8480
77
8082
82
80
82
Sta
tic v
olta
ge (k
Pa)
Sound level: Front of blower suction 1m Air volume m3/min
Sta
tic v
olta
ge (k
Pa)
Single suction direct acting type (horizontal motor)Turbo fan (backward curved vane blower)
Centrifugal Blower KTS TypeKT Type
4
■Development drawing
Casing
Impeller tap washer
Packing
Damper
Damper (Note 1)
Discharge screen (Note 2)
Hexagon socket head screw (Note 3)
Impeller tap bolt (Note 3)
Impeller tap washer (Note 3)
Impeller key (Note 3)
Impeller
Casing
Motor base
Motor
Seat packing
Discharge phase flange
Suction phase flange
Seat packing
Round flange
Suction screen
BaffleScreen
Suction phase flangePacking
Impeller tap bolt
Casing
Impeller key
Impeller
Discharge phase flange
Motor base
Shaft seal
Shaft seal pusher
Casing base Motor
Note) There is no baffle for 3.7kW products and a damper is installed directly on the suction phase flange (casting).Note) There is neither damper nor baffle on heat-resistant type products.
Note 1) The damper is installed on the round flange after suction phase flange and seat packing are removed.Note 2) The discharge screen is attached to 0.1kW and 0.2kW products.Note 3) An impeller can be secured using a hexagon socket head screw on 0.1kW, 0.2kW or 0.4kW products and using impeller key, impeller tap washer and impeller tap bolt for 1.0kW products
1) KT type (output: 0.1-0.4kW, 1.0kW)
2) KT type (output: 0.75kW, 1.5-3.7kW)
3) KTS type
Casing
Impeller tap bolt
Impeller tap washer
Impeller key
Impeller
Ring Shaft seal
Casing base
Motor
Motor base
Shaft seal pusher
Single suction direct acting type (horizontal motor)Turbo fan (backward curved vane blower)
Centrifugal BlowerKTS TypeKT Type
5
■Assembly drawing
■Dimensional tableModel
Body
A D E1 E2 F φG1 φG2L OH φM1 φN1 φQ1 R1 φM2 φN2 φQ2 R2 I J S U V1 V2 X
115
115
135
135
165
165
190
242
242
281
281
338
338
393
100
100
115
115
130
130
150
270
270
309
309
365
365
433
150
150
170
170
200
200
240
201
201
235
235
318
318
338
40
40
45
45
60
60
70
120
120
120
120
140
140
180
136
136
136
136
154
154
200
6
6
6
6
6
6
10
42
42
42
42
45
45
50
81
81
94
94
120
120
152
140
140
140
140
160
160
230
110
110
110
110
130
130
147
120
120
120
120
140
140
200
80
80
80
80
90
90
100
15
15
15
15
20
20
22
40
40
45
45
60
60
80
10
10
10
10
10
10
15
92
92
108
108
136
136
170
6
6
6
6
6
6
10
22
22
28
28
42
42
40
97
97
97
97
123
123
148
63
63
75
75
97
97
123
50
50
55
55
70
70
90
0.1
0.1
0.2
0.2
0.4
0.4
1.0
KT-010S
KT-010T
KT-020S
KT-020T
KT-040S
KT-040T
KT-100T
4×φ10 hole
4×φ10 hole
4×φ10 hole
4×φ10 hole
4×φ10 hole
4×φ10 hole
4×φ12 hole
7.0
7.0
10.0
9.5
14.5
13.0
23.0
Suction phase flange Discharge phase flange BaseOutput(kw)
Foundationbolt hole
Approximatemass (kg)
(Including a motor)
Only three-phase products are available for inverter operation.Note) Take precautions for use of inverter In order to avoid abnormal vibration, jump resonance frequency of eigenvalues such as blower, motor, blower+foundation by setting of inverter.
Suction phase flange
φM1
4×φQ1 hole
φN1
φG1(Outer size)
Discharge phase flange
φM2
4×φQ2 hole R2
φN2
φG2(Outer size)
R1
I
X S X
Foundation bolt hole
V2
UV1
J
H
E2
(F)
(D)
E1
φ G2
(O)
L
φG1
A
φ22H
E2
(F)
(D)
E1
φ G2
(O)
φ22
L
φG1
A
BH-R
BH-L
Single suction direct acting type (horizontal motor)Turbo fan (backward curved vane blower)
Centrifugal Blower KT Type
6
■Assembly drawing
■Dimensional table
H
φQ
V1
U1
E1
F
C
A
φP L (D1)
φP
E1H
F
A
B
A
CH
B
φP
E1
F
R
φP
φM
φE(Outer size)
4×φ10 hole
V1
U1
V2
J U2
V3
Foundation bolt hole
Foundation bolt hole(spare)
φQ
Suction phase flange
X
T
φN
4×φ10 holeS
I
φG(Outer size)
Suction phase flange0.75~2.2kW 3.7kW
φN
φQ
T
φG(Outer size)
4×φ10 hole
TH-R
TV-R
Discharge phase flange
BH-R
50Hz
ModelBody
A B C D1 E1 F H L φG φN φQ T φE φM φP R I J S U1 U2 V1 V2 V3 X
KT-5075
KT-5150
KT-5220
KT-5370
Suction phase flange Discharge phase flange BaseOutput(kw)
Foundationbolt hole
60Hz
ModelBody
A B C D1 E1 F H L φG φN φQ T φE φM φP R I J S U1 U2 V1 V2 V3 X
KT-6075
KT-6150
KT-6220
KT-6370
KT-B075
KT-B150
KT-B220
KT-B370
8×φ12 hole
8×φ15 hole
8×φ15 hole
8×φ15 hole
8×φ12 hole
8×φ15 hole
8×φ15 hole
8×φ15 hole
Suction phase flange Discharge phase flange BaseOutput(kw)
Foundationbolt hole
Approximatemass (kg)
(Not Including a motor)
-Also models with the discharge direction of TV-L, TH-L and BH-L can be manufactured as a standard.Note) For installation of a blower, use 4 foundation bolt holes of U2 dimension pitch with 2 bolts (one side). Or use 4 foundation bolt holes (spare) of V2 dimension pitch with 2 bolts (one side).Note) Take precautions for use of inverter In order to avoid abnormal vibration, jump resonance frequency of eigenvalues such as blower, motor, blower+foundation by setting of inverter.
Approximatemass (kg)
(Not Including a motor)
220
230
260
290
0.75
1.5
2.2
3.7
280
295
325
370
260
273
300
342
292
331
336
388
220
230
260
295
262
272
312
342
330
340
380
430
94
97
102
107
175
175
175
200
210
210
210
260
230
230
230
280
50
50
50
50
123
123
148
175
152
152
180
210
170
170
200
230
40
40
50
50
300
340
340
400
190
250
250
320
260
300
300
360
70
100
105
110
120
120
120
160
95
130
135
140
120
120
120
160
20
20
20
20
8×φ12 hole
8×φ15 hole
8×φ15 hole
8×φ15 hole
14.5
23
28
40.5
50.7
65
65
65
220
230
260
290
220
230
260
290
0.75
1.5
2.2
3.7
0.75
1.5
2.2
3.7
280
295
325
370
280
295
325
370
260
273
300
342
260
273
300
342
292
331
336
388
292
331
336
388
220
230
260
295
220
230
260
295
262
272
312
342
262
272
312
342
330
340
380
430
330
340
380
430
94
97
102
107
94
97
102
107
175
175
175
200
175
175
175
200
210
210
210
260
210
210
210
260
230
230
230
280
230
230
230
280
50
50
50
50
50
50
50
50
123
123
148
175
123
123
148
175
152
152
180
210
152
152
180
210
170
170
200
230
170
170
200
230
40
40
50
50
40
40
50
50
300
340
340
400
300
340
340
400
190
250
250
320
190
250
250
320
260
300
300
360
260
300
300
360
70
100
105
110
70
100
105
110
120
120
120
160
120
120
120
160
95
130
135
140
95
130
135
140
120
120
120
160
120
120
120
160
20
20
20
20
20
20
20
20
14.5
23
28
40.5
14.5
23
28
40.5
50.7
65
65
65
50.7
65
65
65
Single suction direct acting type (horizontal motor)Turbo fan (backward curved vane blower)
Centrifugal BlowerKT Type
7
■Assembly drawing
V1
U1
V2
J U2
V3
Foundation bolt hole
Foundation bolt hole(spare)
X
S
I
TH-R
TV-R
BH-R
ModelBody
A B C D1 D2 D3 φE1 E2 F φG H K1 K2 K3 L1 L2 φM φN O φP φQ
290
300
290
350
290
300
290
350
263
280
310
350
263
280
310
350
250
260
290
325
250
260
290
325
220
230
260
295
220
230
260
295
110
110
120
135
110
110
120
135
550
570
640
725
550
570
640
725
115
125
141
160
115
125
141
160
100
100
120
140
100
100
120
140
305
315
360
410
305
315
360
410
160
160
160
190
160
160
160
190
330
340
380
430
330
340
380
430
620
640
670
780
620
640
670
780
635
655
740
840
635
655
740
840
580
600
670
755
580
600
670
755
555
575
650
735
555
575
650
735
553
580
600
700
553
580
600
700
152
152
180
210
152
152
180
210
210
210
210
260
210
210
210
260
395
440
500
530
395
440
500
530
170
170
200
230
170
170
200
230
230
230
230
280
230
230
230
280
0.75
1.5
2.2
3.7
0.75
1.5
2.2
3.7
KTS-6075
KTS-6150
KTS-6220
KTS-6370
KTS-B075
KTS-B150
KTS-B220
KTS-B370
Output(kW)
ModelBody
A B C D1 D2 D3 φE1 E2 F φG H K1 K2 K3 L1 L2 φM φN O φP φQ
290
300
290
350
263
280
310
350
250
260
290
325
220
230
260
295
110
110
120
135
550
570
640
725
115
125
141
160
100
100
120
140
305
315
360
410
160
160
160
190
330
340
380
430
620
640
670
780
635
655
740
840
580
600
670
755
555
575
650
735
553
580
600
700
152
152
180
210
210
210
210
260
395
440
500
530
170
170
200
230
230
230
230
280
0.75
1.5
2.2
3.7
KTS-5075
KTS-5150
KTS-5220
KTS-5370
Output(kW)
ModelI J S U1 U2 V1 V2 V3 X Thickness
300
340
340
400
210
250
250
320
260
300
300
360
91
108
118
129
120
120
120
160
126
138
148
159
120
120
120
160
20
20
20
20
50.5
65
65
65
t3
t6
t6
t6
KTS-5075
KTS-5150
KTS-5220
KTS-5370
4×φ12 hole
4×φ15 hole
4×φ15 hole
4×φ15 hole
21
30
40
60
Base Foundationbolt hole
Approximate mass (kg)(Not including a motor)
-Also models with the discharge direction of TV-L, TH-L and BH-L can be manufactured as a standard.Note) For installation of a blower, use 4 foundation bolt holes of U2 dimension pitch with 2 bolts (one side). Or use 4 foundation bolt holes (spare) of V2 dimension pitch with 2 bolts (one side).Note) Take precautions for use of inverter In order to avoid abnormal vibration, jump resonance frequency of eigenvalues such as blower, motor, blower+foundation by setting of inverter.
Thickness
φN
4×M8
HA
K1
t5
φE1φP
D1FC
L1
<Discharge flange>
Ventilation direction
Rotation direction
φGφQ
U1V1
5 E2(O MAX)
4×M8
φM
φN
Thickness
4×M8φE1
φP
t5A B
L2
FH
K2
D1
D3
Ventilation direction
Rotation direction
K3
L2A
C
φE1H
φP
Thickness
t5
B
φN
4×M8
D2
D1
Rotation direction
Ventilation direction
■Dimensional table
50Hz
60Hz
ModelI J S U1 U2 V1 V2 V3 X Thickness
300
340
340
400
300
340
340
400
210
250
250
320
210
250
250
320
260
300
300
360
260
300
300
360
91
108
118
129
91
108
118
129
120
120
120
160
120
120
120
160
126
138
148
159
126
138
148
159
120
120
120
160
120
120
120
160
20
20
20
20
20
20
20
20
50.5
65
65
65
50.5
65
65
65
t3
t6
t6
t6
t3
t6
t6
t6
KTS-6075
KTS-6150
KTS-6220
KTS-6370
KTS-B075
KTS-B150
KTS-B220
KTS-B370
4×φ12 hole
4×φ15 hole
4×φ15 hole
4×φ15 hole
4×φ12 hole
4×φ15 hole
4×φ15 hole
4×φ15 hole
21
30
40
60
21
30
40
60
Base Foundationbolt hole
Approximate mass (kg)(Not including a motor)
Single suction direct acting type (horizontal motor)Turbo fan (backward curved vane blower)
Centrifugal Blower KTS Type
8
■Internal structure drawing
Code Qty
1
2
3
4
5
6
7
8
9
Casing
Impeller
Impeller hub
Impeller tap bolt
Suction flange
Suction phase flange
Discharge phase flange
Motor table
Motor
1
1
1
1
1
1
1
1
1
MaterialsPart name
Code Qty
1
2
3
4
5
6
7
8
9
10
11
12
Casing
Impeller
Impeller hub
Impeller tap washer
Impeller tap bolt
Impeller key
Impeller tap bolt
Suction flange
Suction phase flange
Discharge phase flange
Motor table
Motor
1
1
1
1
1
1
1
1
1
1
1
1
MaterialsPart name
1) KT type (Output: 0.1-0.4kW)
2) KT type (output: 1.0kW)
12346
7 8
9
5
12345 6 7
89 10 11
12
ADC12
SECC
FCD450
SCM435
ADC12
SPCC
SPCC
SPHC
ADC12
SECC
FCD450
SS400
SWCH
S45C
SCM435
ADC12
SPCC
SPCC
SPHC
Single suction direct acting type (horizontal motor)Turbo fan (backward curved vane blower)
Centrifugal BlowerKT Type
9
Code Qty
1
2
3
4
5
6
7
8
9
10
11
12
13
Casing
Impeller
Impeller boss
Impeller tap washer
Impeller tap bolt
Impeller key
Suction phase flange
Casing base
Motor base
Discharge phase flange
Shaft seal
Shaft seal pusher
Motor
1
1
1
1
1
1
1
1
1
1
1
1
1
MaterialsPart name
Code Qty
1
2
3
4
5
6
7
8
9
10
11
Casing
Impeller
Impeller boss
Impeller tap washer
Impeller tap bolt
Impeller key
Casing base
Motor base
Shaft seal
Shaft seal pusher
Motor
1
1
1
1
1
1
1
1
1
1
1
MaterialsPart name
10
7
6
3
5
4
2
1 8 12 11 13
9
*1 In the case of KT-5370(T), 6370(T) and B370(T), material of suction phase flange is AC2B.
3) KT type (output: 0.75kW, 1.5-3.7kW)
4) KTS type
1
2
10
3
4
6
7
8
119
5
AC4C
SPCC・SECC
FCD450
SS400
SUS304
S45C
SPCC *1
SPCC
SPCC
SPCC
ーSUS304
ー
SUS304
SUS304
SUS303
SUS303
SUS304
S45C
SUS304
SUS304
ーSUS304
ー
Single suction direct acting type (horizontal motor)Turbo fan (backward curved vane blower)
Centrifugal Blower KTS TypeKT Type
10
MEMO
E-CAT-F-KT-01-B
Turbo Fan
150 Moo 16 Udomsorayuth Rd., T.Bangkrasan, A.Bangpa-In, Ayutthaya 13160 Thailand Tel.+66-3522-0640 Fax.+66-3522-1259
No.285, Yuan Qu Road(N), Bei Qiao, Min Hang District, Shanghai 201109, China Tel.+86-21-6490-9128 Fax.+86-21-6490-9126
Room 1001, 10/F, Olympia Plaza, 255 King|s Road, North Point, Hong Kong Tel.+852-2571-0886 Fax.+852-2571-0619
Head Office 230, Moriwake, Miyuki-cho, Fukuyama-city, Hiroshima, 720-0003, Japan Tel.+81-84-955-1111 Fax.+81-84-955-5777