TROX Prisliste 2019
®
EasyLabLabControl
K6-00
K1 - ARMATURER, RISTECeiling swirl diffusersAIRNAMIC ..................................................................................7VDW ...........................................................................................8TDV-SilentAIR .............................................................................9RFD ..........................................................................................10FD .............................................................................................11TDF-SilentAIR ...........................................................................12VD .............................................................................................13VDL ...........................................................................................14FDE ..........................................................................................16
Design ceiling swirl diffusersXARTO .....................................................................................17ADD ..........................................................................................18
Ceiling swirl diffusers with perforated face plateDCS ..........................................................................................19
Ceiling diffusersVDR ..........................................................................................20DLQ ..........................................................................................21DLQL ........................................................................................22DLQ-AK ....................................................................................24DLK-Fb .....................................................................................25
Slot diffusers for ceiling installationVSD15 ......................................................................................26VSD35 ......................................................................................28VSD35-TZ .................................................................................29VSD50 ......................................................................................32
Slot diffusers for wall installationVSD50-1-LT ..............................................................................35VSD35-3-AZ .............................................................................36
Ventilation grilles for installation into walls, sills or rectangular ductsX-GRILLE Cover .......................................................................37X-GRILLE Basic ........................................................................39SL .............................................................................................43TR .............................................................................................47TRS ..........................................................................................50TRS-K .......................................................................................53
Ventilation grilles for floor installation ARR ..........................................................................................54
Ventilation grilles for installation into circular ductsTRS-R .......................................................................................55
Volume flow rate balancing AGW .........................................................................................56DGW .........................................................................................57ASW .........................................................................................58
Displacement flow diffuser for Installation on a wallQLE ..........................................................................................59QLF ...........................................................................................60QLV ...........................................................................................62
Displacement flow diffuser for wall installationQLW-AZ ....................................................................................64
Freestanding displacement flow diffuserQLV-360 ....................................................................................65
Displacement diffusersQSH ..........................................................................................67
Impulse diffusersISH ............................................................................................68
Jet nozzlesTJN ...........................................................................................69
Jet nozzlesDUK ..........................................................................................70
Disc valvesLVS ...........................................................................................72
Z-LVS ........................................................................................73
Floor diffusersFBA ...........................................................................................74FBK ...........................................................................................75
Staircase swirl diffusersSD .............................................................................................76
Control unitsLON-WA TDC ...........................................................................77
K2 - KØLEBAFLERUnits for suspended ceilingsDID312 .....................................................................................78DID300B ...................................................................................80DID632 .....................................................................................82DID642 .....................................................................................84DID600B-L ................................................................................86DID604 .....................................................................................88DID614 .....................................................................................89DID-R ........................................................................................91
Units for bulkheadsDID-E ........................................................................................92
Freely suspended unitsSMART BEAM ..........................................................................93IDH ...........................................................................................94
Wall and under sill unitsQLI ............................................................................................95
Under sill unitsIDB ............................................................................................96
Under floor unitsBID ............................................................................................97
Passive chilled beamsPKV ..........................................................................................98
Control equipment for air-water systemsLWS control equipment ..........................................................100
Under sill unitsFSL-B-ZAB .............................................................................102SCHOOLAIR-B .......................................................................103
Vertical unitsFSL-V-ZAB ..............................................................................104SCHOOLAIR-V .......................................................................105
Ceiling unitsSCHOOLAIR-D .......................................................................106
Control systemsX-AIRCONTROL .....................................................................107
Connecting hosesFS ...........................................................................................108
K3 - SPJÆLD, RISTE, LYDDÆMPEREMultileaf dampersJZ ...........................................................................................109
Multileaf dampersJZ-LL ......................................................................................119
External weather louvresWG .........................................................................................131WGK .......................................................................................139WGF .......................................................................................142WG-JZ ....................................................................................144WG-KUL .................................................................................150
Non-return dampersUL ...........................................................................................153KUL .........................................................................................155ARK ........................................................................................157
Pressure relief dampersARK2 ......................................................................................159
Shut-off dampersNAK ........................................................................................161
DoorsST ...........................................................................................163BS ...........................................................................................167
Splitter sound attenuatorsMSA ........................................................................................169XSA.........................................................................................170MSA, XSA ...............................................................................171MKA ........................................................................................175XKA ........................................................................................177RKA ........................................................................................180
Circular silencersCA ...........................................................................................182CB...........................................................................................183CS ...........................................................................................184CF ...........................................................................................185CAK ........................................................................................186
K4 - BRANDSPJÆLDFire dampersFK-EU .....................................................................................187FKA-EU ..................................................................................204FKS-EU...................................................................................218FKR-EU ..................................................................................224FKRS-EU ................................................................................228KU-K30 ...................................................................................231KA-EU .....................................................................................233FV-EU .....................................................................................234FVZ-K30 .................................................................................235
Smoke protection dampersJZ-RS .....................................................................................236
Duct smoke detectorsRM-O-VS-D .............................................................................238RM-O-3-D ...............................................................................239
Smoke control dampersEK-EU .....................................................................................240
TROXNETCOM LONModules ..................................................................................243
TROXNETCOM AS-iMaster and display units .........................................................244Controllers and repeaters .......................................................245Switching power supply units ..................................................246Power supply units ..................................................................247Pre-configured switch boxes ...................................................248Modules ..................................................................................249AS-i installation .......................................................................250
Adjustment and addressing devices .......................................251
Decentralised operating and monitoring systemsTNC-EASYCONTROL ............................................................252TNC-LINKBOX ........................................................................253Modbus/BACnet modules .......................................................254
K5 - REGULATORERVARYCONTROLLVC .........................................................................................255TVR ........................................................................................256TVJ .........................................................................................258TVT .........................................................................................261TZ-Silenzio .............................................................................264TA-Silenzio ..............................................................................265TVZ .........................................................................................266TVA .........................................................................................267TVM ........................................................................................268TVRK ......................................................................................269
Secondary silencers for VAV terminal unitsTS ...........................................................................................270TX ...........................................................................................271
Control components for VAV terminal unitsRETROFIT ..............................................................................272RC ..........................................................................................273
Adjustment devices for VAV terminal unitsAdjustment devices .................................................................274
Room control - X-AIRCONTROLX-AIR-ZMAS ...........................................................................275X-AIR-ZMO .............................................................................276X-AIR-CP ................................................................................277X-AIR-SENS ...........................................................................278
CONSTANTFLOWRN ..........................................................................................279EN ...........................................................................................280VFC ........................................................................................282VFL .........................................................................................283
EXCONTROLRN-Ex .....................................................................................284EN-Ex .....................................................................................285
Actuators for CAV controllersRetrofit kits ..............................................................................286
Shut-off dampersAK ...........................................................................................287AKK ........................................................................................288
Flow adjustment dampersVFR ........................................................................................289
Volume flow rate measuring unitsVMR ........................................................................................290VMRK .....................................................................................291VME ........................................................................................292
Heat exchangerWT ..........................................................................................293WL ..........................................................................................296EL ...........................................................................................297
K6 - EASYLAB - LABCONTROLVarycontrolTVLK .......................................................................................298
BE-SEG ..................................................................................299BE-LCD ..................................................................................300TVLK .......................................................................................301VMLK ......................................................................................303TVRK ......................................................................................305
VMRK .....................................................................................308TVR ........................................................................................309VMR ........................................................................................313TVJ .........................................................................................314TVT .........................................................................................316VME ........................................................................................318TZ-Silenzio .............................................................................320TA-Silenzio ..............................................................................322TVZ .........................................................................................324TVA .........................................................................................326TAM ........................................................................................328FSE .........................................................................................329
AccessoriesAccessories for LABCONTROL ..............................................330
Monitoring systemFMS ........................................................................................331
Sensor systemsDifferential pressure transducer ..............................................332
Configuration softwareEasyConnect ..........................................................................333
VAV terminal unitsTVR-Ex ...................................................................................334
Shut-off dampers
AK-Ex .....................................................................................335
K7 - FILTRERINGStandard cell framesSCF ........................................................................................336
Filter wallSIF ..........................................................................................338
Mounting framesMF ..........................................................................................340
Mounting platesMP ..........................................................................................341
Universal casingUCA ........................................................................................342
Ducted particulate filtersKSF .........................................................................................348
Ducted particulate filters for critical requirementsKSFS ......................................................................................349
SpigotKSFSSP ..................................................................................350
Duct casings for particulate filtersDCA ........................................................................................352
Ceiling mounted particulate filtersTFC .........................................................................................353
Wall mounted particulate filterTFW ........................................................................................360
Particulate filter modules for ceilingsTFM ........................................................................................361
Pharmaceutical clean room terminal filtersTFP .........................................................................................362
Pressure measuring devicesMD ..........................................................................................364
Automatic roll filter mediaFMC ........................................................................................365
Roll mediaFMR ........................................................................................367
Cut-to-size pads
FMP ........................................................................................368
Z-line filtersZL ...........................................................................................370
Pocket filters made of non-woven chemical fibresPFC.........................................................................................372
Pocket filters made of non-woven synthetic fibresPFS .........................................................................................373
Pocket filters made of NanoWave® mediumPFN ........................................................................................375
Pocket filters made of non-woven glass fibresPFG ........................................................................................377
Filter insertsMFI .........................................................................................379
Filter elementsMFE ........................................................................................382
Filter cellsMFC ........................................................................................383
Filter panelsMFP ........................................................................................386
Filter cartridgesMFCA .....................................................................................402
Filter panels for clean room technologyMFPCR ...................................................................................403
Filter panels with hoodFHD ........................................................................................409
Filter inserts ACFI ........................................................................................411
Filter cartridgesACFC ......................................................................................412
Filter cells ACF.........................................................................................413
K8- X-CUBEX-CUBEX-CUBE compact ....................................................................411XCC-RO ..................................................................................415XCC-ROM-HM ........................................................................416XCC-HD ..................................................................................417XCC-HM .................................................................................418XCC-HCM ...............................................................................419XCC-EHD ...............................................................................420XCC-CB ..................................................................................421XCC-CD ..................................................................................422XCC-S .....................................................................................423XCC-LON................................................................................424XCC-CPC ...............................................................................425XCC-V .....................................................................................426XCC-P .....................................................................................427XCC-LE ...................................................................................428
Attachment Detail VARYCONTROLControl components ...............................................................430
Calculation exampleSplitter sound attenuators .......................................................431
298
Prisliste 2019DKK brutto ekskl. moms
Optimised for use in laboratories and on fume cupboards
TypeTVLK VAV terminal unit, plastic
Flange No entry: noneFL Flanges on both ends
Nominal size250 - 100 Bluff body 100250 - 160 Bluff body 160250 - D08 Nozzle D08250 - D10 Nozzle D10250 - D16 Nozzle D16
Accessories No entry: noneGK Matching flanges for both ends
Attachments (control component)BB3 Universal controller with static differential pressure transducerBP3 Universal controller with MP bus interface and static
differential pressure transducerBPG Universal controller with MP bus interface and static
differential pressure transducer, fast-running actuator
Operating modeE SingleM MasterS SlaveF Constant value
Signal voltage range For the actual and setpoint value signals0 0 - 10 V DC (only BP3 and BPG)2 2 - 10 V DC
Volume flow rates [m³/h or l/s] min - max for factory setting
TVLKControl component VARYCONTROL
Nominal- size BB3 BP3 BPG FL GK
250 - 100 15 621 20 004 21 277 1 611 1 611250 - 160 15 621 20 004 21 277 1 611 1 611250 - D08 15 883 20 266 21 540 1 611 1 611250 - D10 15 883 20 266 21 540 1 611 1 611250 - D16 15 883 20 266 21 540 1 611 1 611
Base price Surcharge
TVLK – FL / 250 – 100 / GK / BB3 / E0 / 200 – 900
For information regarding the control component type Universal Static, see the Terminal Units catalogue K5 - 1.3
VARIABLE VOLUME FLOW CONTROL - LABCONTROLVARYCONTROLTVLK
299
Prisliste 2019DKK brutto ekskl. moms
For EASYLAB fume cupboard controllers and FMS monitoring systems
-BE-SEG-02 BE-SEG-03
5 469 3 072Base price
Adapter frame for easy installation of the control panel
21
375Price
TypeBE-SEG Control panel for EASYLAB controller TCU3 or fume cupboard monitoring system FMS
Variant02 For all EASYLAB controllers and for monitoring system FMS with OLED display03 For fume cupboard monitoring system FMS
TypeBE-ADP Adapter frame
Variant21 To install BE-SEG-02 into type SCALA fume cupboards by Waldner
BE – SEG – 02
BE – ADP – 21
VARIABLE VOLUME FLOW CONTROL - LABCONTROLEASYLAB
BE-SEG
300
Prisliste 2019DKK brutto ekskl. moms
-
For EASYLAB fume cupboard controllers or room controllers, with text display
Type BE-LCD
BE-LCD5 919
Base price
TypeBE-LCD Control panel with 40-character display
BE – LCD
VARIABLE VOLUME FLOW CONTROL - LABCONTROLEASYLABBE-LCD
301
Prisliste 2019DKK brutto ekskl. moms
-
Optimised for use in laboratories and on fume cupboards
TypeTVLK VAV terminal unit, plastic
Flange No entry: withoutFL Flanges on both ends
Nominal size250 - 100 Bluff body 100250 - 160 Bluff body 160250 - D08 Nozzle D08250 - D10 Nozzle D10250 - D16 Nozzle D16
Accessories No entry: withoutGK Matching flanges for both ends
Attachments (control component)ELAB EASYLAB controller TCU3 with fast- running actuator
Equipment function With face velocity transducerFH-VS Face velocity control With sash distance sensorFH-DS Linear control strategyFH-DV Safety-optimised control strategy With switching steps for switch contacts provided by othersFH-2P 2 switching stepsFH-3P 3 switching steps Without signallingFH-F Volume flow rate constant value
Expansion modules Option 1: Supply voltage No entry: 24 V ACT EM-TRF for 230 V ACU EM-TRF-USV for 230 V AC, provides
uninterruptible power supply (UPS)
Option 2: Communication interface No entry: noneL EM-LON for LonWorks FTT-10AB EM-BAC-MOD-01 for BACnet MS/TPM EM-BAC-MOD-01 for Modbus RTUI EM-IP for BACnet/IP, Modbus/IP and
webserverR EM-IP with real time clock
Option 3: Automatic zero point correction No entry: noneZ EM-AUTOZERO Solenoid valve for
automatic zero point correction
Option 4: Lighting No entry: noneS EM-LIGHT Wired socket for the
connection of lighting and for switching the lighting on/off using the control panel (only with EM-TRF or EM-TRF- USV)
Operating values [m³/h or l/s] Depending on the equipment function VS: min - max DS: min - max DV: min - max 2P: 1 / 2 3P: 1 / 2 / 3 F: 1
Useful additions Control panel for fume cupboard controller, for displaying the functions of the control system according to EN 14175BE-SEG-02 OLED displayBE-LCD-01 40-character display
Type TVLK
Nominal size FH-VS FH-DS
FH-DV
FH-2P FH-3P FH-F
FL GK
250 - 100 22 064 21 540 17 531 1 611 1 611250 - 160 22 064 21 540 17 531 1 611 1 611250 - D08 22 326 21 802 17 794 1 611 1 611250 - D10 22 326 21 802 17 794 1 611 1 611250 - D16 22 326 21 802 17 794 1 611 1 611
Base price Surcharge
TVLK – FL / 250 – 100 / GK / ELAB / FH – VS / ULZS / 200 – 900
Expansion modules
For information on Type EASYLAB control components see the Control Systems catalogue, K6 - 2.1 The BE-SEG or BE-LCD control panel for fume cupboard control is not included in the price.
S: Only with T or U
VARIABLE VOLUME FLOW CONTROL - LABCONTROLEASYLAB
TVLK
T U L B M Z S I R2 847 8 016 3 259 3 259 3 259 2 285 787 8 541 9 665
Surcharge
302
Prisliste 2019DKK brutto ekskl. moms
-
Optimised for use in laboratories and on fume cupboards
TypeTVLK VAV terminal unit, plastic
Flange No entry: noneFL Flanges on both ends
Nominal size250 - 100 Bluff body 100250 - 160 Bluff body 160250 - D08 Nozzle D08250 - D10 Nozzle D10250 - D16 Nozzle D16
Accessories No entry: noneGK Matching flanges for both ends
Attachments (control component)ELAB EASYLAB controller TCU3 with fast-running actuator
Equipment function
Control with single controllerEC Extract air controller
External volume flow rate settingE0 Voltage signal 0 - 10 V DCE2 Voltage signal 2 - 10 V DC2P On-site switch contacts for 2 switching steps3P On-site switch contacts for 3 switching stepsF Volume flow rate constant value, without signalling
Expansion modules Option 1: Supply voltage No entry: 24 V ACT EM-TRF for 230 V ACU EM-TRF-USV for 230 V AC, provides uninterruptible power
supply (UPS)
Option 2: Communication interface No entry: noneL EM-LON for LonWorks FTT-10AB EM-BAC-MOD-01 for BACnet MS/TPM EM-BAC-MOD-01 for Modbus RTUI EM-IP for BACnet/IP, Modbus/IP and webserverR EM-IP with real time clock
Option 3: Automatic zero point correction No entry: noneZ EM-AUTOZERO Solenoid valve for automatic zero point
correction
Operating values [m3/h or l/s, Pa] E0, E2: min / max 2P: 1 / 2 3P: 1 / 2 / 3 F: 1
Type TVLK
Nominal size
E0 E2
2P 3P F
FL GK
250 - 100 17 531 17 531 1 611 1 611250 - 160 17 531 17 531 1 611 1 611250 - D08 17 794 17 794 1 611 1 611250 - D10 17 794 17 794 1 611 1 611250 - D16 17 794 17 794 1 611 1 611
Base price Surcharge
TVLK – FL / 250 – 100 / GK / ELAB / EC – E0 / ULZ / ...
Expansion modulesT U L B M I R Z S
2 847 8 016 3 259 3 259 3 259 8 541 9 665 2 285 787Surcharge
For information on Type EASYLAB control components see the Control Systems catalogue, K6 - 2.1
/S: only in connection with T or U
VARIABLE VOLUME FLOW CONTROL - LABCONTROLEASYLABTVLK
303
Prisliste 2019DKK brutto ekskl. moms
-
For the measurement of volume flow rates in fume cupboards
TypeVMLK Volume flow rate measuring unit, plastic
Flange No entry: noneFL Flanges on both ends
Nominal size [mm]250-100 Bluff body 100250-160 Bluff body 160250 - D08 Nozzle D08250 - D10 Nozzle D10250 - D16 Nozzle D16
Accessories No entry: noneGK Matching flanges for both ends
Attachments (control component)ELAB EASYLAB controller TCU3
Equipment function With face velocity transducerFH-VS Face velocity control With sash distance sensorFH-DS Linear control strategyFH-DV Safety-optimised control strategy With switching steps for on-site switch contactsFH-2P 2 switching stepsFH-3P 3 switching steps Without signallingFH-F Volume flow rate constant value
Expansion modules Option 1: Supply voltage No entry: 24 V ACT EM-TRF for 230 V ACU EM-TRF-USV for 230 V AC, provides
uninterruptible power supply (UPS)
Option 2: Communication interface No entry: noneL EM-LON for LonWorks FTT-10AB EM-BAC-MOD-01 for BACnet MS/TPM EM-BAC-MOD-01 for Modbus RTUI EM-IP for BACnet/IP, Modbus/IP and
webserverR EM-IP with real time clock
Option 3: Automatic zero point correction No entry: noneZ EM-AUTOZERO Solenoid valve for
automatic zero point correction
Option 4: Lighting No entry: noneS EM-LIGHT Wired socket for the
connection of lighting and for switching the lighting on/off using the control panel (only with EM-TRF or EM-TRF- USV)
Operating values [m³/h or l/s] Depending on the equipment function VS: min - max DS: min - max DV: min - max 2P: 1 / 2 3P: 1 / 2 / 3 F: 1
Useful additions Control panel for fume cupboard controller, for displaying the functions of the control system according to EN 14175BE-SEG-** 2-character displayBE-LCD-01 40-character display
Type VMLK
Nominal size FH-VS ¹⁾ FH-DS
FH-DV
FH-2P FH-3P FH-F
FL GK
250-100 18 618 18 093 14 085 1 611 1 611250-160 18 618 18 093 14 085 1 611 1 611250-D08 18 880 18 355 14 347 1 611 1 611250-D10 18 880 18 355 14 347 1 611 1 611250-D16 18 880 18 355 14 347 1 611 1 611
Base price Surcharge
VMLK – FL / 250 – 100 / GK / ELAB / FH – VS / ULZS / 200 – 900
Expansion modulesT U L B M Z S I R
2 847 8 016 3 259 3 259 3 259 8 541 9 665 2 285 9.383Surcharge
For information on Type EASYLAB control components see the Control Systems catalogue, K6 - 2.1 The BE-SEG or BE-LCD control panel for fume cupboard control is not included in the price.
S: Only with T or U
VARIABLE VOLUME FLOW CONTROL - LABCONTROLEASYLAB
VMLK
304
Prisliste 2019DKK brutto ekskl. moms
-
For the measurement of volume flow rates in ducts with contaminated air from laboratories
TypeVMLK Volume flow rate measuring unit, plastic
FlangeNo entry: noneFL Flanges on both ends
Nominal size [mm]250 - 100 Bluff body 100250 - 160 Bluff body 160250 - D08 Nozzle D08250 - D10 Nozzle D10250 - D16 Nozzle D16
AccessoriesNo entry: noneGK Matching flanges for both ends
AttachmentsELAB EASYLAB TCU3
Equipment functionEC Extract air recording
Voltage range for the actual value signalE0 Voltage signal 0 - 10 V DCE2 Voltage signal 2 - 10 V DC
Module expansions Option 1: Power supply No entry: 24 V ACT EM-TRF for 230 V ACU EM-TRF-USV for 230 V AC, provides uninterruptible power
supply (UPS)
Option 2: Communication interface No entry: noneL EM-LON for LonWorks FTT-10AB EM-BAC-MOD-01 for BACnet MS/TPM EM-BAC-MOD-01 for Modbus RTUI EM-IP for BACnet/IP, Modbus/IP and webserverR EM-IP with real time clock
Option 3: Automatic zero point correction No entry: noneZ EM-AUTOZERO Solenoid valve for automatic zero point
correction
Type VMLK
Nominal size
E0 E2 FL GK
250-100 14 085 1 611 1 611250-160 14 085 1 611 1 611250-D08 14 347 1 611 1 611250-D10 14 347 1 611 1 611250-D16 14 347 1 611 1 611
Base price Surcharge
VMLK – FL / 250 – 100 / GK / ELAB / EC – E0 / ULZ
Expansion modulesT U L B M Z S I R
2 847 8 016 3 259 3 259 3 259 2 285 787 8 541 9 665Surcharge
For information on Type EASYLAB control components see the Control Systems catalogue, K6 - 2.1
/S: only in connection with T or U
VARIABLE VOLUME FLOW CONTROL - LABCONTROLEASYLABVMLK
305
Prisliste 2019DKK brutto ekskl. moms
-
For contaminated air, room control
TypeTVRK VAV terminal unit, plastic
Flange No entry: noneFL Flanges on both ends
Nominal size [mm]125, 160, 200, 250, 315, 400
Accessories No entry: noneGK Matching flanges for both ends
Attachment (control component)ELAB EASYLAB controller TCU3 with fast-running actuator
Equipment function Room controlRE Extract air control (Room Exhaust)PC Differential pressure control
Single operationEC Extract air controller
External volume flow rate setting Only for single operationE0 Voltage signal 0 - 10 V DCE2 Voltage signal 2 - 10 V DC2P On-site switch contacts for 2 switching steps3P On-site switch contacts for 3 switching stepsF Volume flow rate constant value, without signalling
Module expansions Option 1: Power supply No entry: 24 V ACT EM-TRF for 230 V ACU EM-TRF-USV for 230 V AC, provides uninterruptible power
supply (UPS)
Option 2: Communication interface No entry: noneL EM-LON for LonWorks FTT-10AB EM-BAC-MOD-01 for BACnet MS/TPM EM-BAC-MOD-01 for Modbus RTUI EM-IP for BACnet/IP, Modbus/IP and webserverR EM-IP with real time clock
Option 3: Automatic zero point correction No entry: noneZ EM-AUTOZERO Solenoid valve for automatic zero point
correction
Additional functions Only for room control (equipment function) Raum management function has been deactivatedLAB Extract air led system (laboratories)CLR Supply air led system (clean rooms) Raum management function is activeLAB-RMF Extract air led system (LAB)CLR-RMF Supply air led system (CLR)
Operating values [m3/h or l/s, Pa For equipment function 'room control' with additional function RMF Total room extract air/supply air 1: Standard mode 2: Reduced operation 3: Increased operation 4: Constant room supply air 5: Constant room extract air 6: Supply air/extract air difference Δpsetpoint: Setpoint pressure (only with differential pressure control) For equipment function 'single operation' E0, E2: min / max 2P: 1 / 2 3P: 1 / 2 / 3 F: 1
Useful additions Room control panel (only for room control)BE-LCD-01 40-character display
TVRK – FL / 160 / GK / ELAB / EC – E0 / ULZ / ...
TVRK – FL / 160 / GK / ELAB / RE / ULZ / LAB / ...
VARIABLE VOLUME FLOW CONTROL - LABCONTROLEASYLAB
TVRK
306
Prisliste 2019DKK brutto ekskl. moms
-
Type TVRK
Nominal size
E0 E2
2P 3P F
RE PC FL GK
125 18 693 18 693 18 693 22 439 1 124 1 124160 18 880 18 880 18 880 22 626 1 236 1 236200 19 404 19 404 19 404 23 150 1 311 1 311250 20 041 20 041 20 041 23 787 1 611 1 611315 22 663 22 663 22 663 26 409 1 798 1 798400 24 761 24 761 24 761 28 507 2 772 2 772
Base price Surcharge
Expansion modulesT U L B M Z S I R
2 847 8 016 3 259 3 259 3 259 2 285 787 8 541 9 665Surcharge
For information on Type EASYLAB control components see the Control Systems catalogue, K6 - 2.1/PC: The differential pressure transducer for room pressure control is not included in the price.
/S: only in connection with T or U
VARIABLE VOLUME FLOW CONTROL - LABCONTROLEASYLABTVRK
307
Prisliste 2019DKK brutto ekskl. moms
-
For contaminated air, fume cupboard control
TypeTVRK VAV terminal unit, plastic
Flange No entry: noneFL Flanges on both ends
Nominal size [mm]125, 160, 200, 250, 315, 400
Accessories No entry: noneGK Matching flanges for both ends
Attachments (control component)ELAB EASYLAB controller TCU3 with fast-
running actuator
Equipment function With face velocity transducerFH-VS Face velocity control With sash distance sensorFH-DS Linear control strategyFH-DV Safety-optimised control strategy With switching steps for on-site switch contactsFH-2P 2 switching stepsFH-3P 3 switching steps Without signallingFH-F Volume flow rate constant value
Expansion modules Option 1: Supply voltage No entry: 24 V ACT EM-TRF for 230 V ACU EM-TRF-USV for 230 V AC, provides
uninterruptible power supply (UPS)
Option 2: Communication interface No entry: noneL EM-LON for LonWorks FTT-10AB EM-BAC-MOD-01 for BACnet MS/TPM EM-BAC-MOD-01 for Modbus RTUI EM-IP for BACnet/IP, Modbus/IP and
webserverR EM-IP with real time clock
Option 3: Automatic zero point correction
No entry: noneZ EM-AUTOZERO Solenoid valve for
automatic zero point correction
Option 4: Lighting No entry: noneS EM-LIGHT Wired socket for the
connection of lighting and for switching the lighting on/off using the control panel (only with EM-TRF or EM-TRF- USV)
Operating values [m³/h or l/s] Depending on the equipment function VS: min - max DS: min - max DV: min - max 2P: 1 / 2 3P: 1 / 2 / 3 F: 1
Useful additions Control panel for fume cupboard
controller, for displaying the functions of the control system according to EN 14175
BE-SEG-** OLED displayBE-LCD-01 40-character display
Type TVRK
Nominal size FH-VS FH-DS
FH-DV
FH-2P FH-3P FH-F
FL GK
125 23 225 22 701 18 693 1 124 1 124160 23 413 22 888 18 880 1 236 1 236200 23 937 23 413 19 404 1 311 1 311250 24 574 24 049 20 041 1 611 1 611315 27 196 26 672 22 663 1 798 1 798400 29 294 28 769 24 761 2 772 2 772
Base price Surcharge
TVRK – FL / 160 / GK / ELAB / FH – VS / ULZS / 200 – 900
Expansion modulesT U L B M Z S I R
2 847 8 016 3 259 3 259 3 259 2 285 787 8 541 9 665Surcharge
For information on Type EASYLAB control components see the Control Systems catalogue, K6 - 2.1 The BE-SEG or BE-LCD control panel for fume cupboard control is not included in the price.
/S: only in connection with T or U
VARIABLE VOLUME FLOW CONTROL - LABCONTROLEASYLAB
TVRK
308
Prisliste 2019DKK brutto ekskl. moms
-
For the measurement of volume flow rates in ducts with contaminated air
TypeVMRK Volume flow rate measuring unit, plastic
Flange No entry: noneFL Flanges on both ends
Nominal size [mm]125, 160, 200, 250, 315, 400
Accessories No entry: noneGK Matching flanges for both ends
AttachmentsELAB EASYLAB TCU3
Equipment functionEC Extract air recording
Voltage range for the actual value signalE0 Voltage signal 0 - 10 V DCE2 Voltage signal 2 - 10 V DC
Module expansions Option 1: Power supply No entry: 24 V ACT EM-TRF for 230 V ACU EM-TRF-USV for 230 V AC, provides uninterruptible power
supply (UPS)
Option 2: Communication interface No entry: noneL EM-LON for LonWorks FTT-10AB EM-BAC-MOD-01 for BACnet MS/TPM EM-BAC-MOD-01 for Modbus RTUI EM-IP for BACnet/IP, Modbus/IP and webserverR EM-IP with real time clock
Option 3: Automatic zero point correction No entry: noneZ EM-AUTOZERO Solenoid valve for automatic zero point
correction
Type VMRK
Nominal size
E0 E2 FL GK
125 15 508 1 124 1 124160 15 696 1 236 1 236200 16 220 1 311 1 311250 16 857 1 611 1 611315 19 479 1 798 1 798400 21 577 2 772 2 772
Base price Surcharge
VMRK – FL / 160 / GK / ELAB / EC – E0 / ULZ
Expansion modulesT U L B M Z S I R
2 847 8 016 3 259 3 259 3 259 2 285 787 8 541 9 665Surcharge
For information on Type EASYLAB control components see the Control Systems catalogue, K6 - 2.1
/S: only in connection with T or U
VARIABLE VOLUME FLOW CONTROL - LABCONTROLEASYLABVMRK
309
Prisliste 2019DKK brutto ekskl. moms
-
For the most diverse applications regarding standard volume flow rate ranges
TypeTVR VAV terminal unit
Acoustic cladding No entry: noneD With acoustic cladding
Material No entry: galvanised sheet steelP1 Powder-coated (RAL 7001), silver greyA2 Stainless steel
Flange No entry: noneFL Both ends (not for TVR-D-P1)
Nominal size [mm] DN
Accessories No entry: noneD2 Lip seals on both endsG2 Matching flanges for both ends
Attachments (control component)ELAB EASYLAB controller TCU3 with fast-running actuator
Equipment function Room controlRS Supply air control (Room Supply)RE Extract air control (Room Exhaust)PC Differential pressure control
Single operationSC Supply air controllerEC Extract air controller
External volume flow rate setting Only for single operationE0 Voltage signal 0 - 10 V DCE2 Voltage signal 2 - 10 V DC2P On-site switch contacts for 2 switching steps3P On-site switch contacts for 3 switching stepsF Volume flow rate constant value, without signalling
Module expansions Option 1: Power supply No entry: 24 V ACT EM-TRF for 230 V ACU EM-TRF-USV for 230 V AC, provides uninterruptible power
supply (UPS)
Option 2: Communication interface No entry: noneL EM-LON for LonWorks FTT-10AB EM-BAC-MOD-01 for BACnet MS/TPM EM-BAC-MOD-01 for Modbus RTUI EM-IP for BACnet/IP, Modbus/IP and webserverR EM-IP with real time clock
Option 3: Automatic zero point correction No entry: noneZ EM-AUTOZERO Solenoid valve for automatic zero point
correction
Additional functions Only for room control (equipment function) Raum management function has been deactivatedLAB Extract air led system (laboratories)CLR Supply air led system (clean rooms) Raum management function is activeLAB-RMF Extract air led system (LAB)CLR-RMF Supply air led system (CLR)
Operating values [m3/h or l/s, Pa] For equipment function 'room control' with additional function RMF Total room extract air/supply air 1: Standard mode 2: Reduced operation 3: Increased operation 4: Constant room supply air 5: Constant room extract air 6: Supply air/extract air difference Δpsetpoint: Setpoint pressure (only with differential pressure control) For equipment function 'single operation' E0, E2: min / max 2P: 1 / 2 3P: 1 / 2 / 3 F: 1
Useful additions Room control panelBE-LCD-01 40-character display
TVR – D – ... – FL / 160 / G2 / ELAB / EC – E0 / ULZ / ...
TVR – D – ... – FL / 160 / G2 / ELAB / RS / ULZ / LAB / ...
VARIABLE VOLUME FLOW CONTROL - LABCONTROLEASYLAB
TVR
310
Prisliste 2019DKK brutto ekskl. moms
-
Type TVR
Nominal size
E0 E2
2P 3P F
RS RE PC
100 15 134 15 134 15 134 18 880125 15 171 15 171 15 171 18 917160 15 209 15 209 15 209 18 955200 15 246 15 246 15 246 18 992250 15 359 15 359 15 359 19 105315 15 583 15 583 15 583 19 329400 15 808 15 808 15 808 19 554
Base price
Type TVR
TVR-…- TVR-…-A2-
Nominal
size D P1 FL D2 G2 A2 FL G2
100 862 1 386 300 337 300 3 109 899 899125 899 1 386 300 337 300 3 109 899 899160 899 1 536 337 375 337 3 334 1 011 1 011200 1 011 1 611 412 375 412 3 446 1 236 1 236250 1 161 1 611 487 375 487 3 821 1 461 1 461315 1 424 2 023 524 412 524 4 345 1 573 1 573400 1 911 2 510 637 412 637 5 020 1 911 1 911
Surcharge
Expansion modulesT U L B M Z S I R
2 847 8 016 3 259 3 259 3 259 2 285 787 8 541 9 665Surcharge
For information on Type EASYLAB control components see the Control Systems catalogue, K6 - 2.1 PC: The differential pressure transducer for room pressure control is not included in the price.
Restricted availability of equipment combinations-P1, -A2 cannot be combined with -D and -FL
/S: only in connection with T or U
VARIABLE VOLUME FLOW CONTROL - LABCONTROLEASYLABTVR
311
Prisliste 2019DKK brutto ekskl. moms
-
For the most diverse applications regarding standard volume flow rate ranges, fume cupboard control
TypeTVR VAV terminal unit
Acoustic cladding No entry: noneD With acoustic cladding
Material No entry: galvanised sheet steelP1 Powder-coated (RAL 7001), silver greyA2 Stainless steel
Flange No entry: noneFL Both ends (not for TVR-D-P1)
Nominal size [mm]100125160200250315400
Accessories No entry: noneD2 Lip seals on both endsG2 Matching flanges for both ends
Attachments (control component)ELAB EASYLAB controller TCU3 with fast-running actuator
Equipment function With face velocity transducerFH-VS Face velocity control With sash distance sensorFH-DS Linear control strategyFH-DV Safety-optimised control strategy With switching steps for on-site switch contactsFH-2P 2 switching stepsFH-3P 3 switching steps Without signallingFH-F Volume flow rate constant value
Expansion modules Option 1: Supply voltage
No entry: 24 V ACT EM-TRF for 230 V ACU EM-TRF-USV for 230 V AC, provides uninterruptible power
supply (UPS)
Option 2: Communication interface No entry: noneL EM-LON for LonWorks FTT-10AB EM-BAC-MOD-01 for BACnet MS/TPM EM-BAC-MOD-01 for Modbus RTUI EM-IP for BACnet/IP, Modbus/IP and webserverR EM-IP with real time clock
Option 3: Automatic zero point correction No entry: noneZ EM-AUTOZERO Solenoid valve for automatic zero point
correction
Option 4: Lighting No entry: noneS EM-LIGHT Wired socket for the connection of lighting and for
switching the lighting on/off using the control panel (only with EM-TRF or EM-TRF-USV)
Operating values [m³/h or l/s] Depending on the equipment function VS: min - max DS: min - max DV: min - max 2P: 1 / 2 3P: 1 / 2 / 3 F: 1
Useful additions Control panel for fume cupboard controller, for displaying the
functions of the control system according to EN 14175BE-SEG-** OLED displayBE-LCD-01 40-character display
TVR – D – ... – FL / 160 / G2 / ELAB / FH – VS / ULZS / 200 – 900
VARIABLE VOLUME FLOW CONTROL - LABCONTROLEASYLAB
TVR
312
Prisliste 2019DKK brutto ekskl. moms
-
Type TVR
Nominal size FH-VS FH-DS
FH-DV
FH-2P FH-3P FH-F
100 19 667 19 142 15 134125 19 704 19 180 15 171160 19 741 19 217 15 209200 19 779 19 254 15 246250 19 891 19 367 15 359315 20 116 19 592 15 583400 20 341 19 816 15 808
Base price
Type TVR
TVR-…- TVR-…-A2-
Nominal
size D P1 FL D2 G2 A2 FL G2
100 862 1 386 300 337 300 3 109 899 899125 899 1 386 300 337 300 3 109 899 899160 899 1 536 337 375 337 3 334 1 011 1 011200 1 011 1 611 412 375 412 3 446 1 236 1 236250 1 161 1 611 487 375 487 3 821 1 461 1 461315 1 424 2 023 524 412 524 4 345 1 573 1 573400 1 911 2 510 637 412 637 5 020 1 911 1 911
Surcharge
Expansion modulesT U L B M Z S I R
2 847 8 016 3 259 3 259 3 259 2 285 787 8 541 9 665Surcharge
For information on Type EASYLAB control components see the Control Systems catalogue, K6 - 2.1: The BE-SEG or BE-LCD control panel for fume cupboard control is not included in the price.
Restricted availability of equipment combinations-P1, -A2 cannot be combined with -D and -FL
S: Only with T or U
VARIABLE VOLUME FLOW CONTROL - LABCONTROLEASYLABTVR
313
Prisliste 2019DKK brutto ekskl. moms
-
For the measurement of volume flow rates in ducts
TypeVMR Circular volume flow rate measuring unit
Material No entry: galvanised sheet steelP1 Powder-coated, silver grey (RAL 7001)A2 Stainless steel
Flange No entry: noneFL Flanges on both ends
Nominal size [mm]100, 125, 160, 200, 250, 315, 400
Accessories No entry: noneD2 Lip seals on both endsG2 Matching flanges for both ends
Attachments (control component)ELAB EASYLAB TCU3
Equipment functionSC Supply air recordingEC Extract air recording
Voltage range for the actual value signalE0 Voltage signal 0 - 10 V DCE2 Voltage signal 2 - 10 V DC
Module expansions Option 1: Power supply No entry: 24 V ACT EM-TRF for 230 V ACU EM-TRF-USV for 230 V AC, provides uninterruptible power
supply (UPS)
Option 2: Communication interface No entry: noneL EM-LON for LonWorks FTT-10AB EM-BAC-MOD-01 for BACnet MS/TPM EM-BAC-MOD-01 for Modbus RTUI EM-IP for BACnet/IP, Modbus/IP and webserverR EM-IP with real time clock
Option 3: Automatic zero point correction No entry: noneZ EM-AUTOZERO Solenoid valve for automatic zero point
correction
Type VMR
Nominal size
E0 E2
100 11 950125 11 987160 12 025200 12 062250 12 175315 12 399400 12 624
Base price
Expansion modules
VMR – P1 – FL / 160 / G2 / ELAB / EC – E0 / ULZ
Type VMR
VMR-…- VMR-…-A2-
Nominal
size P1 FL D2 G2 A2 FL G2
100 1 386 300 337 300 3 109 899 899125 1 386 300 337 300 3 109 899 899160 1 536 337 375 337 3 334 1 011 1 011200 1 611 412 375 412 3 446 1 236 1 236250 1 611 487 375 487 3 821 1 461 1 461315 2 023 524 412 524 4 345 1 573 1 573400 2 510 637 412 637 5 020 1 911 1 911
SurchargeFor information on Type EASYLAB control components see the Control Systems catalogue, K6 - 2.1
NOTEP1, A2 cannot be combined with D and FL
VARIABLE VOLUME FLOW CONTROL - LABCONTROLEASYLAB
VMR
T U L B M Z I R2 847 8 016 3 259 3 259 3 259 2 285 8 541 9 665
Surcharge
314
Prisliste 2019DKK brutto ekskl. moms
-
For normal and high volume flow rate ranges
TypeTVJ VAV terminal unit
Acoustic cladding No entry: noneD With acoustic cladding
Material No entry: galvanised sheet steelP1 Powder-coated (RAL 7001), silver grey
Nominal size [mm] B × H
Attachments (control component)ELAB EASYLAB controller TCU3 with fast-running actuator
Equipment function Room controlRS Supply air control (Room Supply)RE Extract air control (Room Exhaust)PC Differential pressure control
Single operationSC Supply air controllerEC Extract air controller
External volume flow rate setting Only for single operationE0 Voltage signal 0 - 10 V DCE2 Voltage signal 2 - 10 V DC2P On-site switch contacts for 2 switching steps3P On-site switch contacts for 3 switching stepsF Volume flow rate constant value, without signalling
Module expansions Option 1: Power supply No entry: 24 V ACT EM-TRF for 230 V ACU EM-TRF-USV for 230 V AC, provides uninterruptible power
supply (UPS)
Option 2: Communication interface No entry: noneL EM-LON for LonWorks FTT-10AB EM-BAC-MOD-01 for BACnet MS/TP
M EM-BAC-MOD-01 for Modbus RTUI EM-IP for BACnet/IP, Modbus/IP and webserverR EM-IP with real time clock
Option 3: Automatic zero point correction No entry: noneZ EM-AUTOZERO Solenoid valve for automatic zero point
correction
Additional functions Only for room control (equipment function) Raum management function has been deactivatedLAB Extract air led system (laboratories)CLR Supply air led system (clean rooms) Raum management function is activeLAB-RMF Extract air led system (LAB)CLR-RMF Supply air led system (CLR)
Operating values [m3/h or l/s, Pa For equipment function 'room control' with additional function RMF Total room extract air/supply air 1: Standard mode 2: Reduced operation 3: Increased operation 4: Constant room supply air 5: Constant room extract air 6: Supply air/extract air difference Δpsetpoint: Setpoint pressure (only with differential pressure
control) For equipment function 'single operation' E0, E2: min / max 2P: 1 / 2 3P: 1 / 2 / 3 F: 1
Useful additions Room control panelBE-LCD-01 40-character display
TVJ – D – P1 / 600×400 / ELAB / RS / ULZ / LAB / ...
TVJ – D / P1 / 600×400 / ELAB / EC – E0 / ULZ / ...
VARIABLE VOLUME FLOW CONTROL - LABCONTROLEASYLABTVJ
315
Prisliste 2019DKK brutto ekskl. moms
-
Type TVJ
B H RS RE PC EC-E0
EC-E2
EC-2P EC-3P EC-F
D P1
200 100 15 359 19 105 15 359 15 359 1 161 862300 15 434 19 180 15 434 15 434 1 199 862400 15 508 19 254 15 508 15 508 1 274 937500 15 546 19 292 15 546 15 546 1 311 937600 15 696 19 442 15 696 15 696 1 349 974200 200 15 696 19 442 15 696 15 696 1 199 1 086300 15 808 19 554 15 808 15 808 1 236 1 124400 15 883 19 629 15 883 15 883 1 311 1 124500 15 995 19 741 15 995 15 995 1 424 1 199600 16 108 19 854 16 108 16 108 1 424 1 199700 16 220 19 966 16 220 16 220 1 498 1 274800 16 333 20 079 16 333 16 333 1 536 1 274300 300 15 995 19 741 15 995 15 995 1 274 1 274400 16 108 19 854 16 108 16 108 1 386 1 311500 16 258 20 004 16 258 16 258 1 424 1 311600 16 333 20 079 16 333 16 333 1 498 1 386700 16 445 20 191 16 445 16 445 1 573 1 386800 16 632 20 378 16 632 16 632 1 611 1 424900 16 745 20 491 16 745 16 745 1 686 1 424
1000 16 895 20 641 16 895 16 895 1 686 1 536400 400 16 295 20 041 16 295 16 295 1 424 1 424500 16 445 20 191 16 445 16 445 1 461 1 498600 16 595 20 341 16 595 16 595 1 498 1 498700 16 707 20 453 16 707 16 707 1 611 1 573800 16 857 20 603 16 857 16 857 1 648 1 611900 17 007 20 753 17 007 17 007 1 723 1 611
1000 17 157 20 903 17 157 17 157 1 761 1 723500 500 17 082 20 828 17 082 17 082 1 573 1 761600 17 232 20 978 17 232 17 232 1 648 1 836700 17 456 21 202 17 456 17 456 1 686 1 948800 17 606 21 352 17 606 17 606 1 761 1 948900 17 794 21 540 17 794 17 794 1 836 1 985
1000 18 018 21 764 18 018 18 018 1 911 1 985600 600 17 494 21 240 17 494 17 494 1 723 2 060800 17 906 21 652 17 906 17 906 1 836 2 173
1000 18 355 22 101 18 355 18 355 1 948 2 210800 800 18 468 22 214 18 468 18 468 1 985 2 397
1000 18 917 22 663 18 917 18 917 2 098 2 5471000 1000 19 554 23 300 19 554 19 554 2 248 2 847
Base price Surcharge
Expansion modules
For information on Type EASYLAB control components see the Control Systems catalogue, K6 - 2.1/PC: The differential pressure transducer for room pressure control is not included in the price.
VARIABLE VOLUME FLOW CONTROL - LABCONTROLEASYLAB
TVJ
T U L B M Z I R2 847 8 016 3 259 3 259 3 259 2 285 8 541 9 665
Surcharge
316
Prisliste 2019DKK brutto ekskl. moms
-
For normal and high volume flow rate ranges and air-tight shut-off
TypeTVT VAV terminal unit
Acoustic cladding No entry: noneD With acoustic cladding
Material No entry: galvanised sheet steelP1 Powder-coated (RAL 7001), silver grey
Nominal size [mm] B × H
Attachments (control component)ELAB EASYLAB controller TCU3 with fast-running actuator
Equipment function Room controlRS Supply air control (Room Supply)RE Extract air control (Room Exhaust)PC Differential pressure control
Single operationSC Supply air controllerEC Extract air controller
External volume flow rate setting Only for single operationE0 Voltage signal 0 - 10 V DCE2 Voltage signal 2 - 10 V DC2P On-site switch contacts for 2 switching steps3P On-site switch contacts for 3 switching stepsF Volume flow rate constant value, without signalling
Module expansions Option 1: Power supply No entry: 24 V ACT EM-TRF for 230 V ACU EM-TRF-USV for 230 V AC, provides uninterruptible power
supply (UPS)
Option 2: Communication interface No entry: noneL EM-LON for LonWorks FTT-10AB EM-BAC-MOD-01 for BACnet MS/TP
M EM-BAC-MOD-01 for Modbus RTUI EM-IP for BACnet/IP, Modbus/IP and webserverR EM-IP with real time clock
Option 3: Automatic zero point correction No entry: noneZ EM-AUTOZERO Solenoid valve for automatic zero point
correction
Additional functions Only for room control (equipment function) Raum management function has been deactivatedLAB Extract air led system (laboratories)CLR Supply air led system (clean rooms) Raum management function is activeLAB-RMF Extract air led system (LAB)CLR-RMF Supply air led system (CLR)
Operating values [m3/h or l/s, Pa For equipment function 'room control' with additional function RMF Total room extract air/supply air 1: Standard mode 2: Reduced operation 3: Increased operation 4: Constant room supply air 5: Constant room extract air 6: Supply air/extract air difference Δpsetpoint: Setpoint pressure (only with differential pressure
control) For equipment function 'single operation' E0, E2: min / max 2P: 1 / 2 3P: 1 / 2 / 3 F: 1
Useful additions Room control panelBE-LCD-01 40-character display
TVT – D – P1 / 600×400 / ELAB / RS / ULZ / LAB / ...
TVT – D / P1 / 600×400 / ELAB / EC – E0 / ULZ / ...
VARIABLE VOLUME FLOW CONTROL - LABCONTROLEASYLABTVT
317
Prisliste 2019DKK brutto ekskl. moms
-
TVT
B H RS RE PC EC-E0
EC-E2
EC-2P EC-3P EC-F
D P1
200 100 15 808 19 554 15 808 15 808 1 161 862300 15 883 19 629 15 883 15 883 1 199 862400 15 995 19 741 15 995 15 995 1 274 937500 16 108 19 854 16 108 16 108 1 311 937600 16 183 19 929 16 183 16 183 1 424 974200 200 16 258 20 004 16 258 16 258 1 199 1 086300 16 408 20 154 16 408 16 408 1 236 1 124400 16 557 20 303 16 557 16 557 1 311 1 124500 16 707 20 453 16 707 16 707 1 424 1 199600 16 857 20 603 16 857 16 857 1 424 1 199700 16 969 20 715 16 969 16 969 1 498 1 274800 17 119 20 865 17 119 17 119 1 536 1 274300 300 16 745 20 491 16 745 16 745 1 274 1 274400 16 857 20 603 16 857 16 857 1 386 1 311500 17 007 20 753 17 007 17 007 1 424 1 311600 17 119 20 865 17 119 17 119 1 498 1 386700 17 194 20 940 17 194 17 194 1 573 1 386800 17 381 21 127 17 381 17 381 1 611 1 424400 400 17 269 21 015 17 269 17 269 1 424 1 424500 17 456 21 202 17 456 17 456 1 461 1 498600 17 569 21 315 17 569 17 569 1 498 1 498700 17 719 21 465 17 719 17 719 1 611 1 573800 17 831 21 577 17 831 17 831 1 648 1 611
Base price Surcharge
Expansion modules
For information on Type EASYLAB control components see the Control Systems catalogue, K6 - 2.1/PC: The differential pressure transducer for room pressure control is not included in the price.
VARIABLE VOLUME FLOW CONTROL - LABCONTROLEASYLAB
TVT
T U L B M Z I R2 847 8 016 3 259 3 259 3 259 2 285 8 541 9 665
Surcharge
318
Prisliste 2019DKK brutto ekskl. moms
For the measurement of volume flow rates in ducts
TypeVME Rectangular volume flow rate measuring unit
Material No entry: galvanised sheet steelP1 Powder-coated (RAL 7001), silver grey
Nominal size [mm] B × H
AttachmentsELAB EASYLAB controller TCU3
Equipment functionSC Supply air recordingEC Extract air recording
Voltage range for the actual value signalE0 Voltage signal 0 - 10 V DCE2 Voltage signal 2 - 10 V DC
Module expansions Option 1: Power supply No entry: 24 V ACT EM-TRF for 230 V ACU EM-TRF-USV for 230 V AC, provides uninterruptible power
supply (UPS)
Option 2: Communication interface No entry: noneL EM-LON for LonWorks FTT-10AB EM-BAC-MOD-01 for BACnet MS/TPM EM-BAC-MOD-01 for Modbus RTUI EM-IP for BACnet/IP, Modbus/IP and webserverR EM-IP with real time clock
Option 3: Automatic zero point correction No entry: noneZ EM-AUTOZERO Solenoid valve for automatic zero point
correction
VME – P1 / 600×400 / ELAB / EC – E0 / ULZ
VARIABLE VOLUME FLOW CONTROL - LABCONTROLEASYLABVME
319
Prisliste 2019DKK brutto ekskl. moms
Type VME
B H E0 E2 P1
200 100 12 175 862300 12 249 862400 12 324 937500 12 362 937600 12 512 974200 200 12 512 1 086300 12 624 1 124400 12 699 1 124500 12 811 1 199600 12 924 1 199700 13 036 1 274800 13 149 1 274300 300 12 811 1 274400 12 924 1 311500 13 074 1 311600 13 149 1 386700 13 261 1 386800 13 448 1 424900 13 561 1 424
1000 13 710 1 536400 400 13 111 1 424500 13 261 1 498600 13 411 1 498700 13 523 1 573800 13 673 1 611900 13 823 1 611
1000 13 973 1 723500 500 13 898 1 761600 14 048 1 836700 14 272 1 948800 14 422 1 948900 14 609 1 985
1000 14 834 1 985600 600 14 310 2 060800 14 722 2 173
1000 15 171 2 210800 800 15 284 2 397
1000 15 733 2 5471000 1000 16 370 2 847
Base price Surcharge
Expansion modules
For information on Type EASYLAB control components see the Control Systems catalogue, K6 - 2.1
VARIABLE VOLUME FLOW CONTROL - LABCONTROLEASYLAB
VME
T U L B M Z I R2 847 8 016 3 259 3 259 3 259 2 285 8 541 9 665
Surcharge
320
Prisliste 2019DKK brutto ekskl. moms
For supply air systems with demanding acoustic requirements and low airflow velocities
TypeTZ-Silenzio VAV terminal unit, supply air
Acoustic cladding No entry: noneD With acoustic cladding
Nominal size125160200250315
Attachments (control component)ELAB EASYLAB controller TCU3 with fast-running actuator
Equipment function Room controlRS Supply air control (Room Supply)PC Differential pressure control
Single operationSC Supply air controller
External volume flow rate setting Only for single operationE0 Voltage signal 0 - 10 V DCE2 Voltage signal 2 - 10 V DC2P On-site switch contacts for 2 switching steps3P On-site switch contacts for 3 switching stepsF Volume flow rate constant value, without signalling
Module expansions Option 1: Power supply No entry: 24 V ACT EM-TRF for 230 V ACU EM-TRF-USV for 230 V AC, provides uninterruptible power
supply (UPS)
Option 2: Communication interface No entry: noneL EM-LON for LonWorks FTT-10AB EM-BAC-MOD-01 for BACnet MS/TPM EM-BAC-MOD-01 for Modbus RTU
I EM-IP for BACnet/IP, Modbus/IP and webserverR EM-IP with real time clock
Option 3: Automatic zero point correction No entry: noneZ EM-AUTOZERO Solenoid valve for automatic zero point
correction
Additional functions Only for room control (equipment function) Raum management function has been deactivatedLAB Extract air led system (laboratories)CLR Supply air led system (clean rooms) Raum management function is activeLAB-RMF Extract air led system (LAB)CLR-RMF Supply air led system (CLR)
Operating values [m3/h or l/s, Pa] For equipment function 'room control' with additional function RMF Total room extract air/supply air 1: Standard mode 2: Reduced operation 3: Increased operation 4: Constant room supply air 5: Constant room extract air 6: Supply air/extract air difference Δpsetpoint: Setpoint pressure (only with differential pressure
control) For equipment function 'single operation' E0, E2: min / max 2P: 1 / 2 3P: 1 / 2 / 3 F: 1
Useful additions Room control panelBE-LCD-01 40-character display
TZ–Silenzio – D / 200 / ELAB / RS / ULZ / LAB / ...
TZ–Silenzio – D / 200 / ELAB / SC – E0 / ULZ / ...
VARIABLE VOLUME FLOW CONTROL - LABCONTROLEASYLABTZ-Silenzio
321
Prisliste 2019DKK brutto ekskl. moms
Type TZ-Silenzio
Nominal size RS PC E0
E2
2P 3P F
D
125 17 606 21 352 17 606 17 606 3 334160 17 943 21 689 17 943 17 943 4 158200 18 618 22 364 18 618 18 618 4 570250 20 116 23 862 20 116 20 116 6 368315 21 127 24 873 21 127 21 127 6 968
Base price Surcharg e
Expansion modules
For information on Type EASYLAB control components see the Control Systems catalogue, K6 - 2.1 PC: The differential pressure transducer for room pressure control is not included in the price.
VARIABLE VOLUME FLOW CONTROL - LABCONTROLEASYLAB
TZ-Silenzio
T U L B M Z I R2 847 8 016 3 259 3 259 3 259 2 285 8 541 9 665
Surcharge
322
Prisliste 2019DKK brutto ekskl. moms
For extract air systems with demanding acoustic requirements and low airflow velocities
TypeTA-Silenzio VAV terminal unit, extract air
Acoustic cladding No entry: noneD With acoustic cladding
Nominal size125160200250315
Attachments (control component)ELAB EASYLAB controller TCU3 with fast-running actuator
Equipment function Room controlRE Extract air control (Room Exhaust)PC Differential pressure control
Single operationEC Extract air controller
External volume flow rate setting Only for single operationE0 Voltage signal 0 - 10 V DCE2 Voltage signal 2 - 10 V DC2P On-site switch contacts for 2 switching steps3P On-site switch contacts for 3 switching stepsF Volume flow rate constant value, without signalling
Module expansions Option 1: Power supply No entry: 24 V ACT EM-TRF for 230 V ACU EM-TRF-USV for 230 V AC, provides uninterruptible power
supply (UPS)
Option 2: Communication interface No entry: noneL EM-LON for LonWorks FTT-10AB EM-BAC-MOD-01 for BACnet MS/TPM EM-BAC-MOD-01 for Modbus RTU
I EM-IP for BACnet/IP, Modbus/IP and webserverR EM-IP with real time clock
Option 3: Automatic zero point correction No entry: noneZ EM-AUTOZERO Solenoid valve for automatic zero point
correction
Additional functions Only for room control (equipment function) Raum management function has been deactivatedLAB Extract air led system (laboratories)CLR Supply air led system (clean rooms) Raum management function is activeLAB-RMF Extract air led system (LAB)CLR-RMF Supply air led system (CLR)
Operating values [m3/h or l/s, Pa] For equipment function 'room control' with additional function RMF Total room extract air/supply air 1: Standard mode 2: Reduced operation 3: Increased operation 4: Constant room supply air 5: Constant room extract air 6: Supply air/extract air difference Δpsetpoint: Setpoint pressure (only with differential pressure
control) For equipment function 'single operation' E0, E2: min / max 2P: 1 / 2 3P: 1 / 2 / 3 F: 1
Useful additions Room control panelBE-LCD-01 40-character display
TA–Silenzio – D / 200 / ELAB / RE / ULZ / LAB / ...
TA–Silenzio – D / 200 / ELAB / EC – E0 / ULZ / ...
VARIABLE VOLUME FLOW CONTROL - LABCONTROLEASYLABTA-Silenzio
323
Prisliste 2019DKK brutto ekskl. moms
Type TA-Silenzio
Nominal size RS PC E0
E2
2P 3P F
D
125 17 606 21 352 17 606 17 606 3 334160 17 943 21 689 17 943 17 943 4 158200 18 618 22 364 18 618 18 618 4 570250 20 116 23 862 20 116 20 116 6 368315 21 127 24 873 21 127 21 127 6 968
Base price Surcharg e
Expansion modules
For information on Type EASYLAB control components see the Control Systems catalogue, K6 - 2.1 PC: The differential pressure transducer for room pressure control is not included in the price.
VARIABLE VOLUME FLOW CONTROL - LABCONTROLEASYLAB
TA-Silenzio
T U L B M Z I R2 847 8 016 3 259 3 259 3 259 2 285 8 541 9 665
Surcharge
324
Prisliste 2019DKK brutto ekskl. moms
For supply air systems with demanding acoustic requirements
TypeTVZ VAV terminal unit, supply air
Acoustic cladding No entry: noneD With acoustic cladding
Nominal size [mm]125160200250315400
Accessories No entry: noneD1 Lip seal
Attachments (control component)ELAB EASYLAB controller TCU3 with fast-running actuator
Equipment function Room controlRS Supply air control (Room Supply)PC Differential pressure control
Single operationSC Supply air controller
External volume flow rate setting Only for single operationE0 Voltage signal 0 - 10 V DCE2 Voltage signal 2 - 10 V DC2P On-site switch contacts for 2 switching steps3P On-site switch contacts for 3 switching stepsF Volume flow rate constant value, without signalling
Module expansions Option 1: Power supply No entry: 24 V ACT EM-TRF for 230 V ACU EM-TRF-USV for 230 V AC, provides uninterruptible power
supply (UPS)
Option 2: Communication interface No entry: noneL EM-LON for LonWorks FTT-10A
B EM-BAC-MOD-01 for BACnet MS/TPM EM-BAC-MOD-01 for Modbus RTUI EM-IP for BACnet/IP, Modbus/IP and webserverR EM-IP with real time clock
Option 3: Automatic zero point correction No entry: noneZ EM-AUTOZERO Solenoid valve for automatic zero point
correction
Additional functions Only for room control (equipment function) Raum management function has been deactivatedLAB Extract air led system (laboratories)CLR Supply air led system (clean rooms) Raum management function is activeLAB-RMF Extract air led system (LAB)CLR-RMF Supply air led system (CLR)
Operating values [m3/h or l/s, Pa For equipment function 'room control' with additional function RMF Total room extract air/supply air 1: Standard mode 2: Reduced operation 3: Increased operation 4: Constant room supply air 5: Constant room extract air 6: Supply air/extract air difference Δpsetpoint: Setpoint pressure (only with differential pressure control) For equipment function 'single operation' E0, E2: min / max 2P: 1 / 2 3P: 1 / 2 / 3 F: 1
Useful additions Room control panelBE-LCD-01 40-character display
TVZ – D / 160 / D1 / ELAB / SC – E0 / ULZ / ...
TVZ – D / 160 / D1 / ELAB / RS / ULZ / LAB / ...
VARIABLE VOLUME FLOW CONTROL - LABCONTROLEASYLABTVZ
325
Prisliste 2019DKK brutto ekskl. moms
Type TVZ Control components LABCONTROL EASYLAB
Nominal size RS PC E0
E2
2P 3P F
D D1
125 17 606 21 352 17 606 17 606 3 334 75160 17 943 21 689 17 943 17 943 4 158 75200 18 618 22 364 18 618 18 618 4 570 75250 20 116 23 862 20 116 20 116 6 368 75315 21 127 24 873 21 127 21 127 6 968 112400 23 525 27 271 23 525 23 525 7 604 112
Base price Surcharge
Expansion modules
For information on Type EASYLAB control components see the Control Systems catalogue, K6 - 2.1/PC: The differential pressure transducer for room pressure control is not included in the price.
VARIABLE VOLUME FLOW CONTROL - LABCONTROLEASYLAB
TVZ
T U L B M Z I R2 847 8 016 3 259 3 259 3 259 2 285 8 541 9 665
Surcharge
326
Prisliste 2019DKK brutto ekskl. moms
For extract air systems with demanding acoustic requirements
TypeTVA VAV terminal unit, extract air
Acoustic cladding No entry: noneD With acoustic cladding
Nominal size [mm]125160200250315400
Accessories No entry: noneD1 Lip seal
Attachments (control component)ELAB EASYLAB controller TCU3 with fast-running actuator
Equipment function Room controlRE Extract air control (Room Exhaust)PC Differential pressure control
Single operationEC Extract air controller
External volume flow rate setting Only for single operationE0 Voltage signal 0 - 10 V DCE2 Voltage signal 2 - 10 V DC2P On-site switch contacts for 2 switching steps3P On-site switch contacts for 3 switching stepsF Volume flow rate constant value, without signalling
Module expansions Option 1: Power supply No entry: 24 V ACT EM-TRF for 230 V ACU EM-TRF-USV for 230 V AC, provides uninterruptible power
supply (UPS)
Option 2: Communication interface No entry: noneL EM-LON for LonWorks FTT-10A
B EM-BAC-MOD-01 for BACnet MS/TPM EM-BAC-MOD-01 for Modbus RTUI EM-IP for BACnet/IP, Modbus/IP and webserverR EM-IP with real time clock
Option 3: Automatic zero point correction No entry: noneZ EM-AUTOZERO Solenoid valve for automatic zero point
correction
Additional functions Only for room control (equipment function) Raum management function has been deactivatedLAB Extract air led system (laboratories)CLR Supply air led system (clean rooms) Raum management function is activeLAB-RMF Extract air led system (LAB)CLR-RMF Supply air led system (CLR)
Operating values [m3/h or l/s, Pa For equipment function 'room control' with additional function RMF Total room extract air/supply air 1: Standard mode 2: Reduced operation 3: Increased operation 4: Constant room supply air 5: Constant room extract air 6: Supply air/extract air difference Δpsetpoint: Setpoint pressure (only with differential pressure control) For equipment function 'single operation' E0, E2: min / max 2P: 1 / 2 3P: 1 / 2 / 3 F: 1
Useful additions Room control panelBE-LCD-01 40-character display
TVA – D / 160 / D1 / ELAB / EC – E0 / ULZ / ...
TVA – D / 160 / D1 / ELAB / RE / ULZ / LAB / ...
VARIABLE VOLUME FLOW CONTROL - LABCONTROLEASYLABTVA
327
Prisliste 2019DKK brutto ekskl. moms
Type TVA
Nominal size RE PC E0
E2
2P 3P F
D D1
125 17 606 21 352 17 606 17 606 3 334 75160 17 943 21 689 17 943 17 943 4 158 75200 18 618 22 364 18 618 18 618 4 570 75250 20 116 23 862 20 116 20 116 6 368 75315 21 127 24 873 21 127 21 127 6 968 112400 23 525 27 271 23 525 23 525 7 604 112
Base price Surcharge
Expansion modules
For information on Type EASYLAB control components see the Control Systems catalogue, K6 - 2.1/PC: The differential pressure transducer for room pressure control is not included in the price.
VARIABLE VOLUME FLOW CONTROL - LABCONTROLEASYLAB
TVA
T U L B M Z I R2 847 8 016 3 259 3 259 3 259 2 285 8 541 9 665
Surcharge
328
Prisliste 2019DKK brutto ekskl. moms
Adapter module for the expansion of the EASYLAB system
TypeTAM Adapter module
Expansion modules Option 1: Supply voltage No entry: 24 V ACT EM-TRF for 230 V ACU EM-TRF-USV for 230 V AC, provides uninterruptible power
supply (UPS)
Option 2: Communication interface No entry: noneL EM-LON for LonWorks-FTT-10AB EM-BAC-MOD-01 for BACnet MS/TPM EM-BAC-MOD-01 for Modbus RTUI EM-IP for BACnet/IP, Modbus/IP and webserverR EM-IP with real time clock
Operating modeLAB Extract air led system (laboratories)LAB-RMF Extract air led system with active room
management function (laboratories)CLR Supply air led system (clean room)CLR-RMF Supply air led system with active room
management function
Operating values [m3/h or l/s, Pa] Only with operating mode LAB-RMF or CLR-RMF1 Total room extract air/supply air - standard mode2 Total room extract air/supply air - reduced operation3 Total room extract air/supply air - increased operation4 Constant supply air5 Constant extract air6 Supply air/extract air differenceΔpsoll Setpoint pressure (only with differential pressure control)
Useful additions: Control panel for fume cupboard controller, for displaying the functions of the control system according to EN 14175BE-TCU-LON-II 40-character display
Type TAM
TAM8 803
Base price
T U L B M I R2 847 8 016 3 259 3 259 3 259 8 541 9 665
Surcharge
TAM / TL / LAB / ...
VARIABLE VOLUME FLOW CONTROL - LABCONTROLEASYLABTAM
329
Prisliste 2019DKK brutto ekskl. moms
TypeFSE Automatic sash device
Accessories 1Actuator01 Universal31 Wesemann DELTA51 Hohenloher71 ARGE81 IC-Inventar
Accessories 2P Passive infrared sensor (motion detector)K P.E. sensor for collision preventionF Pedal switchA Active infrared sensor (presence detector)
Combinations possible
FSE – 01 / PKF
VARIABLE VOLUME FLOW CONTROL - LABCONTROLEASYLAB
FSE
NOTEPrice upon request
330
Prisliste 2019DKK brutto ekskl. moms
LON modules / routers / terminal resistors
LON WA5/B 5 095LON WA5/B TAG 7 904
LON router FT10 / FT10 with terminator 19 667LON router FT10 / XF1250 with terminator 22 926
LON quadruple router FT 10 / XF1250 with 4 terminal resistors 40 906
LON IP router FT10 / Ethernet with terminator 31 017LON quadruple IP router FT10 / Ethernet with 4
terminal resistors 69 226
LON network terminal resistor FT10/FT10 637BACnet MS/TP to IP router 15 546
Price
Additional components
TBS motion detector 24 V AC 4 645 Price
Accessories
CAB-TRD 5 m extension for connecting cable VS-TRD 375
CAB-BE 5 m extension for TCU-LON II control panel connecting cable 337
Price
VARIABLE VOLUME FLOW CONTROL - LABCONTROLAccessoriesAccessories for LABCONTROL
331
Prisliste 2019DKK brutto ekskl. moms
For the monitoring of volume flows
Type FMS
1 2 S G V D5 731 4 720 524 187 187 1 873Base price Surcharge
VS-TRD4 533
Base price
BE-SEG02 03
5 469 3 072Price
TypeFMS Monitoring system
Variant1 Monitoring system with integral diaphragm pressure transducer and measuring
probe2 Monitoring system for external 0 (2) to 10 V DC signals
AccessoriesS EM-LIGHT-F: LightingG EM-CPL: Mating connector for the EM-LIGHT moduleV EM-VENT: Combined insulation piece and wire clamping bracket for digital output
DO1, fan activationD EM-DDT: Differential pressure transducer for monitoring a supportive flow
FMS – 1 / SGVD
NOTEVS-TRD, BE-SEG-02 and BE-SEG-03 are optional components.
AIR MANAGEMENT CONTROL SYSTEMSMonitoring system
FMS
332
Prisliste 2019DKK brutto ekskl. moms
For the differential pressure recording and control in combination with EASYLAB and TCU-LON-II
Type Differential pressure transducer
699 699-LCD GB604 GB604-CAL6 443 11 313 11 987 13 673
Base price
TypePT Differential pressure transducer
Variants699 Measuring range ±50 or ±100 Pa699-LCD Measuring range ±50 or ±100 Pa, with pressure displayGB604 Measuring range ±100 PaGB604-CAL Measuring range ±100 Pa, with calibration result
PT – GB604
AIR MANAGEMENT CONTROL SYSTEMSSensor systemsDifferential pressure transducer
333
Prisliste 2019DKK brutto ekskl. moms
For the commissioning and diagnosis of EASYLAB components, FSE, and FMS
Type EasyConnect
CAB BC13 111 16 857
Price
SoftwareEasyConnect Configuration software
Interface adapterCABUSB-RS485 and connnecting cable (cable connection)BCBluetooth adapter module BlueCON (wireless communication)
EasyConnect – CAB
AIR MANAGEMENT CONTROL SYSTEMSConfiguration software
EasyConnect
334
Prisliste 2019DKK brutto ekskl. moms
For the control of variable air volume flows in potentially explosive atmospheres (ATEX)
TypeTVR-Ex VAV terminal unit for use in potentially explosive atmospheres
Material No entry: galvanised sheet steelP1 Inner duct powder-coated, silver grey (RAL 7001)A2 Inner duct in stainless steel
Nominal size [mm]125, 160, 200, 250, 315, 400
Attachments (control component) For example Electronic controlS1S Internal controller and actuator
Pneumatic controlPG5 Volume flow controller with actuatorPJ5 Pressure and volume flow cascade (±20 Pa)
Operating values [m³/h or l/s, Pa] Electronic control min - max
Pneumatic control Volume flow rate min - max Pressure and volume flow cascade min - max / Δpsetpoint
Damper blade position Only for spring return actuators and pneumatic actuatorsNO Pressure off/power off to OPENNC Power off/Pressure off to close
Type TVR-Ex
Nominal size TES TEF TEX TEY S1S S1F S1X S1Y PG5 PJ5 PL5 P1 A2
125 113 536 120 240 125 407 132 111 104 308 111 012 116 179 122 883 35 966 47 008 47 008 1 459 3 944160 113 536 120 240 125 407 132 111 104 308 111 012 116 179 122 883 35 966 47 008 47 008 1 617 4 101200 113 536 120 240 125 407 132 111 104 308 111 012 116 179 122 883 35 966 47 008 47 008 1 696 4 259250 113 536 120 240 125 407 132 111 104 308 111 012 116 179 122 883 35 966 47 008 47 008 1 696 4 969315 115 824 122 528 127 694 134 398 106 596 113 300 118 466 125 170 38 253 49 295 49 295 2 130 5 403400 116 928 123 632 128 798 135 502 107 700 114 404 119 570 126 274 39 357 50 399 50 399 2 642 6 310
Base price Surcharge
TVR–Ex – P1 / 125 / S1S / 200 – 400 / NO
EXCONTROLVAV terminal unitsTVR-Ex
335
Prisliste 2017DKK brutto ekskl. moms
Prisliste 2019DKK brutto ekskl. moms
For low-leakage shut-off of volume flows in potentially explosive atmospheres (ATEX)
TypeAK-Ex Shut-off damper for potentially explosive atmospheres
Material No entry: galvanised sheet steelP1 Inner duct powder-coated, silver grey (RAL 7001)A2 Inner duct in stainless steel
Nominal size [mm]125, 160, 200, 250, 315, 400
Actuator ElectronicT0S ActuatorT0F Spring return actuatorT0X Actuator with auxiliary switchT0Y Spring return actuator with auxiliary switch
PneumaticP50 Actuator
Damper blade position Only for spring return actuators and pneumatic actuatorsNO Pressure off/power off to OPENNC Power off/Pressure off to close
Type AK-Ex
Nominal size T0S T0F T0X T0Y P50 P1 A2
125 58 523 65 148 70 393 77 097 19 008 1 459 3 944160 58 523 65 148 70 393 77 097 19 008 1 617 4 101200 58 523 65 148 70 393 77 097 19 008 1 696 4 259250 58 523 65 148 70 393 77 097 19 008 1 696 4 969315 60 810 67 436 72 681 79 385 21 295 2 130 5 403400 61 915 68 540 73 785 80 489 22 400 2 642 6 310
Base price Surcharge
AK-Ex – P1 / 125 / T0F / NO
EXCONTROLShut-off dampers
AK-Ex
12
Tint
kom
mun
ikasj
on |
ww
w.tin
tkom
.no
| F
oto/
Illust
rasj
oner
: Tro
xAur
anor
/ Sh
utte
rsto
ck /
John
er Im
ages
TROX Danmark A/SLyskær 102730 HerlevTlf.: +45 49 14 66 33www.trox.dk
Salgskontor DanmarkLysholt Allé 107100 VejleTlf.: +45 86 25 19 11www.trox.dk
8