troubleshooting manual r4.1

Upload: toan

Post on 02-Jun-2018

276 views

Category:

Documents


1 download

TRANSCRIPT

  • 8/10/2019 Troubleshooting Manual R4.1

    1/77

    FTDG-H750-D830

    FLASHWAVE 4570 RELEASE 4.1

    TROUBLESHOOTING MANUAL (TSMN)

    ISSUE 1, AUGUST 2008

    FUJITSU LIMITED

  • 8/10/2019 Troubleshooting Manual R4.1

    2/77

    Before You Begin

    FLASHWAVE 4570 Release 4.1

    Troubleshooting ManualFUJITSU and FUJITSU Customer Use Only

    FTDG-H750-D830

    Issue 1, August 2008

    Proprietary Rights Notice

    All product or service names mentioned in this document are trademarks or registered trademarks of theirrespective companies.

    This document and its contents are provided by FUJITSU Limited (FUJITSU) for guidance purposes only. This document isprovided as is with no warranties or representations whatsoever, either express or implied, including without limitation theimplied warranties of merchantability and fitness for purpose. FUJITSU does not warrant or represent that the contents ofthis document are error free. Furthermore, the contents of this document are subject to update and change at any timewithout notice by FUJITSU, since FUJITSU reserves the right, without notice, to make changes in equipment design orcomponents as progress in engineering methods may warrant. No part of the contents of this document may be copied,modified, or otherwise reproduced without the express written consent of FUJITSU.

    Unpublished work and only distributed under restriction.

    Copyright FUJITSU LIMITED. All Rights Reserved.

    http://www.fujitsu.com/http://www.fujitsu.com/http://www.fujitsu.com/http://www.fujitsu.com/
  • 8/10/2019 Troubleshooting Manual R4.1

    3/77

    Before You Begin

    FTDG-H750-D830

    Issue 1, August 2008FUJITSU and FUJITSU Customer Use Only

    FLASHWAVE 4570 Release 4.1

    Troubleshooting Manuali

    BEFORE YOU BEGIN

    Read through this manual set carefully and familiarize yourself with the FLASHWAVE4570 equipment before configuring, installing, turning up, performing operation andmaintenance of, and troubleshooting the equipment.

    Keep the manual set at hand so that you can refer to it at any time.

    Observe the notices and instructions provided in this manual set for your proper andsafety installation, use and maintenance of the equipment.

  • 8/10/2019 Troubleshooting Manual R4.1

    4/77

    Before You Begin

    iiFLASHWAVE 4570 Release 4.1

    Troubleshooting ManualFUJITSU and FUJITSU Customer Use Only

    FTDG-H750-D830

    Issue 1, August 2008

    Important Notice on Product Safety

    Elevated voltages are inevitably present at specific points in this electrical equipment.Some of the parts may also have elevated operating temperatures. Systems withforced ventilation have rotating items.

    Non-observance of these conditions and the safety instructions can result in personalinjury or in property damage.

    The system complies with the standard EN 60950-1 / IEC 60950-1. All equipmentconnected has to comply with the applicable safety standards.

    Mount the systems in areas with restricted access only. Only trained and qualifiedpersonnel may install, operate, and maintain the systems.

    !

  • 8/10/2019 Troubleshooting Manual R4.1

    5/77

    Contents

    FTDG-H750-D830

    Issue 1, August 2008FUJITSU and FUJITSU Customer Use Only

    FLASHWAVE 4570 Release 4.1

    Troubleshooting Manualiii

    Contents

    BEFORE YOU BEGIN.....................................................................................................................i

    Important Notice on Product Safety ........................................................................................... 1-2

    CHAPTER 1 Preface...............................................................................................................1-1

    1.1 Intended Audience......................................................................................................1-21.2 Structure of This Document........................................................................................ 1-21.3 Symbols and Conventions.......................................................................................... 1-21.3.1 Symbols Used.............................................................................................................1-31.3.2 Conventions Used....................................................................................................... 1-31.4 History of Changes ..................................................................................................... 1-4

    CHAPTER 2 Alarm Lists..........................................................................................................2-1

    2.1 Equipment Alarms....................................................................................................... 2-22.2 Communication Alarms............................................................................................... 2-32.3 Environmental Alarms................................................................................................. 2-52.4 Quality of Service Alarms ........................................................................................... 2-52.5 Security Alarms...........................................................................................................2-6

    CHAPTER 3 Troubleshooting.................................................................................................. 3-1

    3.1 Equipment Alarms....................................................................................................... 3-23.1.1 Communication_Failure.............................................................................................. 3-23.1.2 Equipment_OverHeating ............................................................................................ 3-23.1.3 Fan_Failure.................................................................................................................3-3

    3.1.4

    Loss_of_Power_Input ................................................................................................. 3-33.1.5 Low_Order_Capacity_Mismatch................................................................................. 3-3

    3.1.6 No_Free_Low_Order_Capacity.................................................................................. 3-43.1.7 OA-Power_Failure ......................................................................................................3-43.1.8 OA-Pump_Bias_out_of_Range .................................................................................. 3-43.1.9 OA-Temperature_out_of_Range................................................................................ 3-53.1.10 PLL_Unlock.................................................................................................................3-53.1.11 Power_Failure............................................................................................................. 3-53.1.12 SC_CF_Module_Absent ............................................................................................. 3-63.1.13 SC_CF_Module_Failure ............................................................................................. 3-63.1.14 SFP_Absent................................................................................................................3-63.1.15 SFP_Failure................................................................................................................3-73.1.16 SFP_Mismatch............................................................................................................3-7

    3.1.17

    SPI-Temperature_out_of_Range.... ............................................................................ 3-73.1.18 Unit_Failure.................................................................................................................3-8

    3.1.19 Unit_Removal .............................................................................................................3-83.1.20 UnitType_Mismatch .................................................................................................... 3-83.1.21 VCXO_Failure.............................................................................................................3-93.2 Communication Alarms............................................................................................... 3-93.2.1 AU_AIS .......................................................................................................................3-93.2.2 AU_LOP......................................................................................................................3-93.2.3 Embedded DCC Channel (n) Failure........................................................................ 3-103.2.4 HCOC27-DCC_Connection_Failure......................................................................... 3-103.2.5 HCOC9-DCC_Connection_Failure........................................................................... 3-103.2.6 HP-DEG....................................................................................................................3-113.2.7 HP-EXC ....................................................................................................................3-11

    3.2.8

    HP-GFP_Customer_Signal_Failure.......................................................................... 3-113.2.9 HP-GFP_Loss_of_Frame_Delineation ..................................................................... 3-12

  • 8/10/2019 Troubleshooting Manual R4.1

    6/77

    Contents

    ivFLASHWAVE 4570 Release 4.1

    Troubleshooting ManualFUJITSU and FUJITSU Customer Use Only

    FTDG-H750-D830

    Issue 1, August 2008

    3.2.10 HP-PLM.....................................................................................................................3-123.2.11 HP-RDI......................................................................................................................3-123.2.12 HP-TIM......................................................................................................................3-13

    3.2.13

    HP-UNEQ..................................................................................................................3-133.2.14 HP-Virtual_Concatenation_LOA ...............................................................................3-13

    3.2.15 HP-Virtual_Concatenation_LOM...............................................................................3-143.2.16 HP-Virtual_Concatenation_TLCT .............................................................................3-143.2.17 Link_Failure...............................................................................................................3-153.2.18 Loss_of_Timing_Input...............................................................................................3-153.2.19 Loss_of_Timing_Output............................................................................................3-163.2.20 LP-DEG.....................................................................................................................3-163.2.21 LP-EXC .....................................................................................................................3-163.2.22 LP-GFP_Customer_Signal_Failure ..........................................................................3-173.2.23 LP-GFP_Loss_of_Frame_Delineation......................................................................3-173.2.24 LP-PLM .....................................................................................................................3-173.2.25 LP-RDI ......................................................................................................................3-18

    3.2.26

    LP-RFI.......................................................................................................................3-183.2.27 LP-TIM ......................................................................................................................3-18

    3.2.28 LP-UNEQ ..................................................................................................................3-193.2.29 LP-Virtual_Concatenation_LOA................................................................................3-193.2.30 LP-Virtual_Concatenation_LOM...............................................................................3-193.2.31 LP-Virtual_Concatenation_TLCT..............................................................................3-203.2.32 MS_AIS.....................................................................................................................3-213.2.33 MS-DCC_Connection_Failure ..................................................................................3-213.2.34 MS_DEG...................................................................................................................3-213.2.35 MS_EXC ...................................................................................................................3-223.2.36 MS-K1/K2_Mismatch ................................................................................................3-223.2.37 MS_RDI.....................................................................................................................3-223.2.38 OA_Gain_High..........................................................................................................3-23

    3.2.39

    OA_Input_LOS..........................................................................................................3-233.2.40 OA_Output_LOS.......................................................................................................3-24

    3.2.41 OA_Output_Power_High ..........................................................................................3-243.2.42 PPI-AIS .....................................................................................................................3-243.2.43 PPI-LOF ....................................................................................................................3-253.2.44 PPI-LOM ...................................................................................................................3-253.2.45 PPI-LOS....................................................................................................................3-253.2.46 PPI-RDI .....................................................................................................................3-263.2.47 RPR-Exceed_Max_Stations .....................................................................................3-263.2.48 RPR-Link_Failure_East.............................................................................................3-263.2.49 RPR-Link_Failure_West............................................................................................3-273.2.50 RPR-Miscabling_East ...............................................................................................3-273.2.51 RPR-Miscabling_West ..............................................................................................3-27

    3.2.52

    RPR-Protection_Misconfig........................................................................................3-28

    3.2.53 RPR-Ringlet0_ReservedA0_Exceeding ...................................................................3-283.2.54 RPR-Ringlet1_ReservedA0_Exceeding ...................................................................3-283.2.55 RPR-Topology_Inconsistent .....................................................................................3-293.2.56 RPR-Topology_Instability .........................................................................................3-293.2.57 RS-DCC_Connection_Failure...................................................................................3-293.2.58 RS_DEG ...................................................................................................................3-303.2.59 RS_EXC....................................................................................................................3-303.2.60 RS_LOF ....................................................................................................................3-303.2.61 RS_TIM.....................................................................................................................3-313.2.62 SPI_LOS ...................................................................................................................3-313.2.63 Synchronization_Signal_Message_Mismatch ..........................................................3-323.2.64 System_Clock_Holdover_Longer .............................................................................3-32

    3.2.65

    System_Clock_Unlocked..........................................................................................3-32

    3.2.66 Timing_Reference_Degrade.....................................................................................3-33

  • 8/10/2019 Troubleshooting Manual R4.1

    7/77

    Contents

    FTDG-H750-D830

    Issue 1, August 2008FUJITSU and FUJITSU Customer Use Only

    FLASHWAVE 4570 Release 4.1

    Troubleshooting Manualv

    3.2.67 Timing_Reference_Failure ....................................................................................... 3-333.2.68 TU-AIS ......................................................................................................................3-333.2.69 TU-LOM ....................................................................................................................3-34

    3.2.70

    TU-LOP.....................................................................................................................3-343.3 Environmental Alarms............................................................................................... 3-34

    3.3.1 ENV_MDI............................................................................................................3-353.4 Quality of Service Alarms ......................................................................................... 3-353.4.1 E1-Negative_Bit-slip_TCA_15m............................................................................... 3-353.4.2 E1-Negative_Bit-slip_TCA_24h................................................................................ 3-353.4.3 E1-Positive_Bit-slip_TCA_15m................................................................................. 3-363.4.4 E1-Positive_Bit-slip_TCA_24h.................................................................................. 3-363.4.5 Ethernet TCA ............................................................................................................3-363.4.6 PDH TCA ..................................................................................................................3-373.4.7 SDH TCA ..................................................................................................................3-383.5 Security Alarms.........................................................................................................3-393.5.1 AccountExpiredOrDisabled....................................................................................... 3-39

    3.5.2

    LogIsFull ...................................................................................................................3-393.5.3 LogOccupancyThresholdReached ........................................................................... 3-40

    3.5.4 Unauthorized_Access_Attempt ................................................................................ 3-403.5.5 Unsuccessful_Logins_Exceeded.............................................................................. 3-40

    CHAPTER 4 Card Replacement ............................................................................................. 4-1

    4.1 Replacing SC Card.....................................................................................................4-24.1.1 SC Card Failure ..........................................................................................................4-34.1.2 CF Card Failure ..........................................................................................................4-44.1.3 Both SC and CF Cards Fail ........................................................................................ 4-44.1.4 Downloading Boot Image............................................................................................ 4-54.1.5 Downloading Software Load....................................................................................... 4-64.1.6 Downloading MIB........................................................................................................4-6

    4.2

    Replacing CC Card..................................................................................................... 4-84.3 Replacing Fan Unit .....................................................................................................4-8

    4.4 Replacing filter unit ..................................................................................................... 4-9

    CHAPTER 5 MIB Switching..................................................................................................... 5-1

    5.1 Different Data Configuration ....................................................................................... 5-25.2 Same Data Configuration ........................................................................................... 5-3

    CHAPTER 6 Optical Connector and Fiber Handling............................................................... 6-1

    CHAPTER 7 Abbreviations......................................................................................................7-1

  • 8/10/2019 Troubleshooting Manual R4.1

    8/77

    Contents

    viFLASHWAVE 4570 Release 4.1

    Troubleshooting ManualFUJITSU and FUJITSU Customer Use Only

    FTDG-H750-D830

    Issue 1, August 2008

    List of Tables

    Table 1-1

    List of Used Conventions ........................................................................................1-3

    Table 1-2 History of Changes..................................................................................................1-4Table 2-1 Equipment Alarms...................................................................................................2-2Table 2-2 Communication Alarms ...........................................................................................2-3Table 2-3 Environmental Alarms .............................................................................................2-5Table 2-4 Quality of Service Alarms........................................................................................2-5Table 2-5 Security Alarms .......................................................................................................2-6

  • 8/10/2019 Troubleshooting Manual R4.1

    9/77

    CHAPTER 1Preface

    FTDG-H750-D830

    Issue 1, August 2008FUJITSU and FUJITSU Customer Use Only

    FLASHWAVE 4570 Release 4.1

    Troubleshooting Manual1-1

    CHAPTER 1

    Preface

  • 8/10/2019 Troubleshooting Manual R4.1

    10/77

    CHAPTER 1Preface

    1-2FLASHWAVE 4570 Release 4.1

    Troubleshooting ManualFUJITSU and FUJITSU Customer Use Only

    FTDG-H750-D830

    Issue 1, August 2008

    This Troubleshooting Manual describes fault-clearing procedures to be performed in reaction

    to alarm events that may occur in the FLASHWAVE 4570 system.

    1.1 Intended Audience

    This document is intended for anyone tasked with clearing fault conditions to restore normal

    system operation. Personnel performing these procedures must have general experience

    with Synchronous Digital Hierarchy (SDH) transport networks as well as specific experience

    with Fujitsu FLASHWAVE 4570 hardware components and network management software.

    Personnel must also comply with all relevant safety practices whenever working with

    FLASHWAVE 4570 equipment.

    1.2 Structure of This Document

    Alarm lists

    When a fault condition occurs, the relevant alarm notification will be generated and displayed

    on craft terminal screens. All FLASHWAVE 4570 alarms are listed in the Alarm lists in

    Chapter 2. The alarm lists are divided into separate tables that match the fault categories as

    presented on craft terminal screens. These categories are as follows:

    Equipment alarms

    Communication alarms

    Environment alarms

    Quality of Service (QoS) alarms

    Security alarms

    Troubleshooting

    For each entry in the Alarm lists, specific fault-clearing procedures are contained in Chapter

    3, Troubleshooting. Click the desired alarm name in the Alarm list to jump directly to the

    instructions for that alarm.

    Described Features

    Some features described in this document may not be available. To identify the features

    released for your project, please refer to the Release Note delivered together with the

    product.

    1.3 Symbols and Conventions

    The following symbols and conventions are used in this document:

    i

  • 8/10/2019 Troubleshooting Manual R4.1

    11/77

    CHAPTER 1Preface

    FTDG-H750-D830

    Issue 1, August 2008FUJITSU and FUJITSU Customer Use Only

    FLASHWAVE 4570 Release 4.1

    Troubleshooting Manual1-3

    1.3.1 Symbols Used

    This symbol identifies notes which, if ignored, can result in bodily harm.

    This symbol identifies notes which, if ignored, can result in damage to the equipment.

    This symbol identifies notes which, if ignored, can result in service interruption.

    This symbol stands for an important note to be paid extra attention to, or additional

    information which extends beyond the immediate context.

    This symbol stands for a cross reference to other chapters in this manual or reference toother manuals.

    This symbol stands for a reference to the online help system of the FLEXR L local craft

    terminal or FLEXR C subnetwork management system software.

    1.3.2 Conventions Used

    Representation Meaning

    Inverted commas Window or wizard titles are represented in inverted commas.

    Example: Open the Help and Support Center window. The NewConnection wizard is displayed.

    Bold Any field or text in the GUI is represented in boldtype. Example:

    Click Shutdownand then click OKto turn off the computer.

    Italic Variables and file extensions are represented initalic.

    Example: Enter 192.168.0.1in the IP addressfield. Click OKto

    produce a .pdfrendition.

    Courier Commands, screen output, file names and paths are represented

    in courier.

    Example:# ping -t 192.168.0.1

    Used for keyboard actions or place holders for concrete names or

    values are represented in . If used for a filenamethe courierfont must be used also.

    Example: The naming convention for the log files is

    .txt, where is the name of the NE sending

    the messages. Press + to open the task

    manager.

    > Used for menu sequences.

    Example: Click File > Print...to print the document.

    Table 1-1 List of Used Conventions

    !!

    Danger

    !!

    Warning

    !!

    Caution

    i

    Help

  • 8/10/2019 Troubleshooting Manual R4.1

    12/77

    CHAPTER 1Preface

    1-4FLASHWAVE 4570 Release 4.1

    Troubleshooting ManualFUJITSU and FUJITSU Customer Use Only

    FTDG-H750-D830

    Issue 1, August 2008

    1.4 History of Changes

    Issue Issue date

    1 August 2008 Initial version

    Table 1-2 History of Changes

  • 8/10/2019 Troubleshooting Manual R4.1

    13/77

    CHAPTER 2Alarm Lists

    FTDG-H750-D830

    Issue 1, August 2008FUJITSU and FUJITSU Customer Use Only

    FLASHWAVE 4570 Release 4.1

    Troubleshooting Manual2-1

    CHAPTER 2

    Alarm Lists

  • 8/10/2019 Troubleshooting Manual R4.1

    14/77

    CHAPTER 2Alarm Lists

    2-2FLASHWAVE 4570 Release 4.1

    Troubleshooting ManualFUJITSU and FUJITSU Customer Use Only

    FTDG-H750-D830

    Issue 1, August 2008

    FLASHWAVE 4570 alarms are divided into the following categories:

    Equipment alarms: originate from specific hardware elements (e.g., traffic card, controller

    card, shelf, etc.) Communication alarms: originate from termination points which represent a particular

    function of the network

    Environmental alarms: originate from telemetry sensors that monitor conditions/ events

    external to the Network Element (NE)

    Quality of Service alarms: originate from termination points where performance

    measurement and threshold supervision is enabled

    Security alarms: originate from termination points which detect the system authentication

    and authorization

    2.1 Equipment Alarms

    Table 2-1lists FLASHWAVE 4570 equipment alarms. Click the alarm name in the table to

    jump directly to the troubleshooting procedure for that alarm.

    Alarm name Alarm Message Text

    Communication_Failure Communication failure

    Equipment_OverHeating Equipment overheating

    Fan_Failure Fan failure

    Loss_of_Power_Input Loss of power input

    Low_Order_Capacity_Mismatch Low order capacity mismatch

    No_Free_Low_Order_Capacity No free low order capacityOA-Power_Failure Optical Amplifier (OA) power failure

    OA-Pump_Bias_out_of_Range OA pump bias out of range

    OA-Temperature_out_of_Range OA temperature out of range

    PLL_Unlock Phase Lock Loop (PLL) unlock

    Power_Failure Power failure

    SC_CF_Module_Absent Compact Flash (CF) card absent

    SC_CF_Module_Failure CF card failure

    SFP_Absent Small Factor Pluggable (SFP) absent

    SFP_Failure SFP failureSFP_Mismatch SFP mismatch

    SPI-Temperature_out_of_Range Synchronous Physical Interface (SPI) laser

    temperature out of range

    Unit_Failure Unit failure

    Unit_Removal Unit removal

    UnitType_Mismatch Unit type mismatch

    VCXO_Failure Voltage Control Crystal Oscillator (VCXO)

    Failure

    Table 2-1 Equipment Alarms

  • 8/10/2019 Troubleshooting Manual R4.1

    15/77

    CHAPTER 2Alarm Lists

    FTDG-H750-D830

    Issue 1, August 2008FUJITSU and FUJITSU Customer Use Only

    FLASHWAVE 4570 Release 4.1

    Troubleshooting Manual2-3

    2.2 Communication Alarms

    Table 2-2lists FLASHWAVE 4570 communication alarms. Click the alarm name in the tableto jump directly to the troubleshooting procedure for that alarm.

    Alarm Name Alarm Message Text

    AU_AIS Administrative Unit (AU) Alarm Indication

    Signal (AIS)

    AU_LOP AU Loss Of Pointer (LOP)

    Embedded DCC channel (n) failure Embedded DCC Channel 1 or 2 failure

    HCOC27-DCC_Connection_Failure High Capacity Overhead Channel (HCOC)

    27 Data Communication Channel (DCC)

    connection failure

    HCOC9-DCC_Connection_Failure HCOC 9 DCC connection failure

    HP-DEG High order Path (HP) signal DEGraded

    (DEG)

    HP-EXC HP EXCessive (EXC) error

    HP-GFP_Customer_Signal_Failure HP Generic Framing Procedure (GFP)

    customer signal failure

    HP-GFP_Loss_of_Frame_Delineation HP GFP loss of frame delineation

    HP-PLM HP PayLoad Mismatch (PLM)

    HP-RDI HP Remote Defect Indication (RDI)

    HP-TIM HP Trace Identifier Mismatch (TIM)HP-UNEQ HP UNEQuipped (UNEQ)

    HP-Virtual_Concatenation_LOA HP virtual concatenation Loss Of Alignment

    (LOA)

    HP-Virtual_Concatenation_LOM HP virtual concatenation Loss Of Multiframe

    (LOM)

    HP-Virtual_Concatenation_TLCT HP virtual concatenation Total Loss of

    Capacity Transmit (TLCT)

    Link_Failure Link failure

    Loss_of_Timing_Input Loss of timing input

    Loss_of_Timing_Output Loss of timing outputLP-DEG Low order Path (LP) signal DEG

    LP-EXC LP EXC error

    LP-GFP_Customer_Signal_Failure LP GFP customer signal failure

    LP-GFP_Loss_of_Frame_Delineation LP GFP loss of frame delineation

    LP-PLM LP PLM

    LP-RDI LP RDI

    LP-RFI LP Remote Failure Indication (RFI)

    LP-TIM LP TIM

    Table 2-2 Communication Alarms

  • 8/10/2019 Troubleshooting Manual R4.1

    16/77

    CHAPTER 2Alarm Lists

    2-4FLASHWAVE 4570 Release 4.1

    Troubleshooting ManualFUJITSU and FUJITSU Customer Use Only

    FTDG-H750-D830

    Issue 1, August 2008

    Alarm Name Alarm Message Text

    LP-UNEQ LP UNEQ

    LP-Virtual_Concatenation_LOA LP virtual concatenation LOA

    LP-Virtual_Concatenation_LOM LP virtual concatenation LOM

    LP-Virtual_Concatenation_TLCT LP virtual concatenation TLCT

    MS_AIS Multiplex Section (MS) AIS

    MS-DCC_Connection_Failure MS DCC connection failure

    MS_DEG MS signal DEG

    MS_EXC MS EXC

    MS-K1/K2_Mismatch K1/K2 mismatch

    MS_RDI MS RDI

    OA_Gain_High OA gain highOA_Input_LOS OA input Loss Of Signal (LOS)

    OA_Output_LOS OA output LOS

    OA_Output_Power_High OA output power high

    PPI-AIS Plesiochronous Digital Hierarchy (PDH)

    Physical Interface (PPI) AIS

    PPI-LOF PPI LOF

    PPI-LOM PPI LOM

    PPI-LOS PPI LOS

    PPI-RDI PPI RDIRPR-Exceed_Max_Stations Resilient Packet Ring (RPR) exceed

    maximum stations

    RPR-Link_Failure_East RPR link failure east

    RPR-Link_Failure_West RPR link failure west

    RPR-Miscabling_East RPR miscabling east

    RPR-Miscabling_West RPR miscabling west

    RPR-Protection_Misconfig RPR protection misconfiguration

    RPR-Ringlet0_ReservedA0_Exceeding RPR ringlet 0 reserved A0 exceeding

    RPR-Ringlet1_ReservedA0_Exceeding RPR ringlet 1 reserved A0 exceeding

    RPR-Topology_Inconsistent RPR topology inconsistent

    RPR-Topology_Instability RPR topology instability

    RS-DCC_Connection_Failure Regeneration Section (RS) DCC connection

    failure

    RS_DEG RS signal DEG

    RS_EXC RS EXC

    RS_LOF RS Loss Of Frame (LOF)

    RS_TIM RS TIM

    SPI_LOS SPI LOS

    Table 2-2 Communication Alarms (Cont.)

  • 8/10/2019 Troubleshooting Manual R4.1

    17/77

  • 8/10/2019 Troubleshooting Manual R4.1

    18/77

    CHAPTER 2Alarm Lists

    2-6FLASHWAVE 4570 Release 4.1

    Troubleshooting ManualFUJITSU and FUJITSU Customer Use Only

    FTDG-H750-D830

    Issue 1, August 2008

    2.5 Security Alarms

    Table 2-5lists S hiT 7080 security alarms. Click the alarm name in the table to jump directlyto the troubleshooting procedure for that alarm.

    Alarm name Alarm Message Text

    accountExpiredOrDisabled Account expired or disabled

    logIsFull Log is full

    logOccupancyThresholdReached Log occupancy threshold reached

    Unauthorized_Access_Attempt Unauthorized access attempt

    Unsuccessful_Logins_Exceeded Unsuccessful logins exceeded

    Table 2-5 Security Alarms

  • 8/10/2019 Troubleshooting Manual R4.1

    19/77

    CHAPTER 3Troubleshooting

    FTDG-H750-D830

    Issue 1, August 2008FUJITSU and FUJITSU Customer Use Only

    FLASHWAVE 4570 Release 4.1

    Troubleshooting Manual3-1

    CHAPTER 3

    Troubleshooting

  • 8/10/2019 Troubleshooting Manual R4.1

    20/77

    CHAPTER 3Troubleshooting

    3-2FLASHWAVE 4570 Release 4.1

    Troubleshooting ManualFUJITSU and FUJITSU Customer Use Only

    FTDG-H750-D830

    Issue 1, August 2008

    This chapter describes the general troubleshooting instructions for each alarm.

    3.1 Equipment Alarms

    The equipment alarms are listed in the following sub-chapters.

    3.1.1 Communication_Failure

    Alarm name Communication_Failure

    Default severity Major

    Alarm object System Controller (SC), High Order Cross Connect

    (HOCC), and Low Order Cross Connect (LOCC)

    cardsGeneral information and causes The communication between a service card and the

    SC, HOCC, or LOCC card fails. This also includes

    communication between the SC, HOCC, and LOCC

    cards.

    Troubleshooting instructions

    1 Reboot or change the service card.

    2 Reboot or change the SC card.

    3 If the alarm persists, contact the next higher level of technical support.

    3.1.2 Equipment_OverHeating

    Alarm name Equipment_OverHeating

    Default severity Major

    Alarm object SC, HOCC, LOCC, and all service cards (not

    including IO cards)

    General information and causes The temperature of the equipment is not in the

    normal working range which is specified in the card

    properties configuration.

    Troubleshooting instructions

    1 Verify the fan unit is working correctly.

    2 Verify the filter unit is clean.

    3 Verify the air-conditioning is working correctly.

    4 Verify the equipment is working correctly.

    5 Verify the card temperature threshold is configured properly.

    6 If the alarm persists, contact the next higher level of technical support.

  • 8/10/2019 Troubleshooting Manual R4.1

    21/77

    CHAPTER 3Troubleshooting

    FTDG-H750-D830

    Issue 1, August 2008FUJITSU and FUJITSU Customer Use Only

    FLASHWAVE 4570 Release 4.1

    Troubleshooting Manual3-3

    3.1.3 Fan_Failure

    Alarm name Fan_Failure

    Default severity Major

    Alarm object Fan unit

    General information and causes The fan unit is defective.

    Troubleshooting instructions

    1 Verify the fans in the fan unit are working correctly.

    2 Change the fan unit.

    3 If the alarm persists, contact the next higher level of technical support.

    3.1.4 Loss_of_Power_Input

    Alarm name Loss_of_Power_Input

    Default severity Major

    Alarm object Power module

    General information and causes The -48 V power input is absent.

    The input power is lower than -40 V.

    The input power is higher than -72 V.

    Troubleshooting instructions

    1 Verify the power cables to the power module are connected correctly.

    2 If the alarm persists, contact the next higher level of technical support.

    3.1.5 Low_Order_Capacity_Mismatch

    Alarm name Low_Order_Capacity_Mismatch

    Default severity Major

    Alarm object NE

    General information and causes Alarm triggered when the Management InformationBase (MIB) configuration files in a newly input SC

    card do not match the actual configuration of the

    LOCC card in the NE.

    Troubleshooting instructions

    1 Download a backup MIB from the Personal Computer (PC) into the CF card of the newly

    inserted SC card. For more information on MIB download, please refer to Chapter 4.1.6.

    2 If the alarm persists, contact the next higher level of technical support.

    If there is no backup MIB the system will have to be reconfigured.!!

    Caution

  • 8/10/2019 Troubleshooting Manual R4.1

    22/77

    CHAPTER 3Troubleshooting

    3-4FLASHWAVE 4570 Release 4.1

    Troubleshooting ManualFUJITSU and FUJITSU Customer Use Only

    FTDG-H750-D830

    Issue 1, August 2008

    3.1.6 No_Free_Low_Order_Capacity

    Alarm name No_Free_Low_Order_Capacity

    Default severity Major

    Alarm object PDHcards

    General information and causes Alarm triggered when a new PDH card is inserted in

    the system, but there is no more available low order

    capacity in the LOCC card.

    Troubleshooting instructions

    1 Upgrade the LOCC capacity.

    2 Delete some existing low order mapping on relevant SDH cards.

    3 Delete some existing low order mapping on unused PDH cards and remove them fromthe system to reallocate low order capacity.

    4 If the alarm persists, contact the next higher level of technical support.

    3.1.7 OA-Power_Failure

    Alarm name OA_Power_Failure

    Default severity Critical

    Alarm object OAcard

    General information and causes The power for the OA card fails.

    Troubleshooting instructions

    1 Change the OA card.

    2 If the alarm persists, contact the next higher level of technical support.

    3.1.8 OA-Pump_Bias_out_of_Range

    Alarm name OA-Pump_Bias_out_of_Range

    Default severity Major

    Alarm object OA card

    General information and causes The OA pump bias exceeds the threshold which is

    specified in the OA port properties configuration.

    Troubleshooting instructions

    1 Verify the OA output power is set properly.

    2 Verify the OA input power is normal.

    3 Verify the OA card is not aging.

    4 If the alarm persists, contact the next higher level of technical support.

  • 8/10/2019 Troubleshooting Manual R4.1

    23/77

    CHAPTER 3Troubleshooting

    FTDG-H750-D830

    Issue 1, August 2008FUJITSU and FUJITSU Customer Use Only

    FLASHWAVE 4570 Release 4.1

    Troubleshooting Manual3-5

    3.1.9 OA-Temperature_out_of_Range

    Alarm name OA-Temperature_out_of_Range

    Default severity Major

    Alarm object OA card

    General information and causes The OA modules temperature exceeds the

    threshold which is specified in the OA port

    properties configuration.

    Troubleshooting instructions

    1 Verify the fan unit is working correctly.

    2 Verify the OA setting is proper.

    3 If the alarm persists, contact the next higher level of technical support.

    3.1.10 PLL_Unlock

    Alarm name PLL_Unlock

    Default severity Major

    Alarm object Card (All cards except HOCC, SC, power module,

    and fan unit)

    General information and causes This alarm is triggered when the PLLis in the

    unlock state.

    Troubleshooting instructions

    1 If fault occurs during card boot or synchronization, please wait till the initialization

    process of the card is complete.

    2 If the alarm continues after initialization is complete, replace the card.

    3 If the alarm persists, contact the next higher level of technical support.

    3.1.11 Power_Failure

    Alarm name Power_Failure

    Default severity Major

    Alarm object Power module

    General information and causes The power module is not working normally.

    Troubleshooting instructions

    1 Change the shelf.

    2 If the alarm persists, contact the next higher level of technical support.

  • 8/10/2019 Troubleshooting Manual R4.1

    24/77

    CHAPTER 3Troubleshooting

    3-6FLASHWAVE 4570 Release 4.1

    Troubleshooting ManualFUJITSU and FUJITSU Customer Use Only

    FTDG-H750-D830

    Issue 1, August 2008

    3.1.12 SC_CF_Module_Absent

    Alarm name SC_CF_Module_Absent

    Default severity Major

    Alarm object SC card

    General information and causes The CF card is absent.

    Troubleshooting instructions

    1 Insert the CF card.

    For more information, please refer to the FLASHWAVE 4570 Installation and Test

    Manual (ITMN).

    2 If the alarm persists, contact the next higher level of technical support.

    3.1.13 SC_CF_Module_Failure

    Alarm name SC_CF_Module_Failure

    Default severity Major

    Alarm object SC card

    General information and causes The CF card can not be accessed.

    Troubleshooting instructions

    1 Change the CF card.

    For more information, please refer to the FLASHWAVE 4570 Installation and Test

    Manual (ITMN).

    2 If the alarm persists, contact the next higher level of technical support.

    3.1.14 SFP_Absent

    Alarm name SFP_Absent

    Default severity Major

    Alarm object Optical portGeneral information and causes The SFPmodule is absent.

    Troubleshooting instructions

    1 Insert the proper SFP module.

    2 If the alarm persists, contact the next higher level of technical support.

  • 8/10/2019 Troubleshooting Manual R4.1

    25/77

    CHAPTER 3Troubleshooting

    FTDG-H750-D830

    Issue 1, August 2008FUJITSU and FUJITSU Customer Use Only

    FLASHWAVE 4570 Release 4.1

    Troubleshooting Manual3-7

    3.1.15 SFP_Failure

    Alarm name SFP_Failure

    Default severity Major

    Alarm object SFP module

    General information and causes The SFP module is not working normally.

    Troubleshooting instructions

    1 Change the SFP module.

    2 If the alarm persists, contact the next higher level of technical support.

    3.1.16 SFP_Mismatch

    Alarm name SFP_Mismatch

    Default severity Major

    Alarm object SFP module

    General information and causes The bit rate of the SFP is lower than the port

    requirement.

    Troubleshooting instructions

    1 Change to a suitable SFP module.

    2 If the alarm persists, contact the next higher level of technical support.

    3.1.17 SPI-Temperature_out_of_Range

    Alarm name SPI-Temperature_out_of_Range

    Default severity Major

    Alarm object STM-64 port

    General information and causes The temperature of the laser exceeds the normal

    range.

    Troubleshooting instructions

    1 Verify the refrigeration part and the bias current part of the laser are working correctly.

    2 Change the 10 Gigabit Small Form Factor Pluggable (XFP) module.

    3 If the alarm persists, contact the next higher level of technical support.

  • 8/10/2019 Troubleshooting Manual R4.1

    26/77

    CHAPTER 3Troubleshooting

    3-8FLASHWAVE 4570 Release 4.1

    Troubleshooting ManualFUJITSU and FUJITSU Customer Use Only

    FTDG-H750-D830

    Issue 1, August 2008

    3.1.18 Unit_Failure

    Alarm name Unit_Failure

    Default severity Major

    Alarm object Cards

    General information and causes The card is defective.

    Troubleshooting instructions

    1 Change the card.

    2 If the alarm persists, contact the next higher level of technical support.

    3.1.19 Unit_Removal

    Alarm name Unit_Removal

    Default severity Major

    Alarm object Cards

    General information and causes The card is absent.

    Troubleshooting instructions

    1 Insert the corresponding card.

    2 If the alarm persists, contact the next higher level of technical support.

    3.1.20 UnitType_Mismatch

    Alarm name UnitType_Mismatch

    Default severity Major

    Alarm object Cards

    General information and causes The inserted card type is not consistent with the

    preconfigured card type.

    Troubleshooting instructions

    1 Insert the correct type of card.

    2 Verify the card type in SEEPROM is set correctly through the cards mini USB.

    3 If the alarm persists, contact the next higher level of technical support.

  • 8/10/2019 Troubleshooting Manual R4.1

    27/77

    CHAPTER 3Troubleshooting

    FTDG-H750-D830

    Issue 1, August 2008FUJITSU and FUJITSU Customer Use Only

    FLASHWAVE 4570 Release 4.1

    Troubleshooting Manual3-9

    3.1.21 VCXO_Failure

    Alarm name VCXO_Failure

    Default severity Major

    Alarm object HOCC card

    General information and causes The VCXOcomponent on the HOCC card has

    failed.

    Troubleshooting instructions

    1 Replace HOCC card.

    2 If the alarm persists, contact the next higher level of technical support.

    3.2 Communication Alarms

    The communication alarms are listed in the following sub-chapters.

    3.2.1 AU_AIS

    Alarm name AU_AIS

    Default severity Minor

    Alarm object SDH AU

    General information and causes The upstream signal is defective.

    Troubleshooting instructions

    1 Troubleshoot the SPI, RS, MS,or AU-LOP alarms in the upstream node.

    2 If the alarm persists, contact the next higher level of technical support.

    3.2.2 AU_LOP

    Alarm name AU_LOP

    Default severity CriticalAlarm object SDH AU

    General information and causes No valid AU-4 pointer is found in the received signal

    due to:

    Line unit failure in the remote node.

    Local tributary unit failure in the station.

    Troubleshooting instructions

    1 Verify the upstream external cable connections are correct.

    2 If the alarm persists, contact the next higher level of technical support.

  • 8/10/2019 Troubleshooting Manual R4.1

    28/77

    CHAPTER 3Troubleshooting

    3-10FLASHWAVE 4570 Release 4.1

    Troubleshooting ManualFUJITSU and FUJITSU Customer Use Only

    FTDG-H750-D830

    Issue 1, August 2008

    3.2.3 Embedded DCC Channel (n) Failure

    Alarm name Embedded DCC channel1 failure

    Default severity Major

    Alarm object NE

    General information and causes DCCcommunication channel has failed.

    Troubleshooting instructions

    1 Verify routing configuration.

    2 If the alarm persists, contact the next higher level of technical support.

    3.2.4 HCOC27-DCC_Connection_Failure

    Alarm name HCOC27-DCC_Connection_Failure

    Default severity Major

    Alarm object SDH HCOC

    General information and causes The HCOC27-DCC is disabled at one side of

    the DCC link.

    DCC link is down.

    Troubleshooting instructions

    1 Verify the HCOC27-DCC is enabled and working normally at both ends of the DCC link.

    2 If the alarm persists, contact the next higher level of technical support.

    3.2.5 HCOC9-DCC_Connection_Failure

    Alarm name HCOC9-DCC_Connection_Failure

    Default severity Major

    Alarm object SDH HCOC

    General information and causes The HCOC9-DCC is disabled at one side of the

    DCC link. DCC link is down.

    Troubleshooting instructions

    1 Verify the HCOC9-DCC is enabled and working normally at both ends of the DCC link.

    2 If the alarm persists, contact the next higher level of technical support.

  • 8/10/2019 Troubleshooting Manual R4.1

    29/77

    CHAPTER 3Troubleshooting

    FTDG-H750-D830

    Issue 1, August 2008FUJITSU and FUJITSU Customer Use Only

    FLASHWAVE 4570 Release 4.1

    Troubleshooting Manual3-11

    3.2.6 HP-DEG

    Alarm name HP-DEG

    Default severity Minor

    Alarm object SDH HP

    General information and causes A degraded signal defect is detected when the

    equivalent Bit Error Rate (BER) exceeds a preset

    threshold of 10-x, x = 5, 6, 7, 8, 9.

    Troubleshooting instructions

    1 Verify the upstream external cabling and equipment are normal.

    2 Verify the threshold is set correctly.

    3 If the alarm persists, contact the next higher level of technical support.

    3.2.7 HP-EXC

    Alarm name HP-EXC

    Default severity Major

    Alarm object SDH HP

    General information and causes An excessive error defect is detected when the

    equivalent BER exceeds a preset threshold of 10-x, x

    = 4, 5.

    Troubleshooting instructions

    1 Verify the upstream external cabling and equipment are normal.

    2 Verify the threshold is set correctly.

    3 If the alarm persists, contact the next higher level of technical support.

    3.2.8 HP-GFP_Customer_Signal_Failure

    Alarm name HP-GFP_Customer_Signal_Failure

    Default severity Critical

    Alarm object Ethernet Wide Area Networks (WAN) ports

    General information and causes The upstream Local Area Networks (LAN) port

    connectivity is down.

    Troubleshooting instructions

    1 Verify the upstream external cabling and equipment are normal.

    2 If the alarm persists, contact the next higher level of technical support.

  • 8/10/2019 Troubleshooting Manual R4.1

    30/77

    CHAPTER 3Troubleshooting

    3-12FLASHWAVE 4570 Release 4.1

    Troubleshooting ManualFUJITSU and FUJITSU Customer Use Only

    FTDG-H750-D830

    Issue 1, August 2008

    3.2.9 HP-GFP_Loss_of_Frame_Delineation

    Alarm name HP-GFP_Loss_of_Frame_Delineation

    Default severity Critical

    Alarm object Ethernet WAN ports

    General information and causes The upstream Ethernet signal fails because of GFP

    synchronization failure.

    Troubleshooting instructions

    1 Verify the upstream connection and equipment are normal.

    2 If the alarm persists, contact the next higher level of technical support.

    3.2.10 HP-PLM

    Alarm name HP-PLM

    Default severity Critical

    Alarm object SDH HP

    General information and causes The mapping modes of the local side and the

    remote side are not the same.

    The expected payload value set via

    management system in the local side is not the

    same as the actual payload value from the

    remote side.

    Troubleshooting instructions

    1 Change the mapping mode of the local node to the same as the remote node.

    2 Change the expected payload value of the local node to the same as the actual payload

    value of the remote node.

    3 If the alarm persists, contact the next higher level of technical support.

    3.2.11 HP-RDI

    Alarm name HP-RDI

    Default severity Minor

    Alarm object SDH HP

    General information and causes The downstream NE receives the malfunctioning

    signal.

    Troubleshooting instructions

    1 React to the far-end alarms.

    2 If the alarm persists, contact the next higher level of technical support.

  • 8/10/2019 Troubleshooting Manual R4.1

    31/77

    CHAPTER 3Troubleshooting

    FTDG-H750-D830

    Issue 1, August 2008FUJITSU and FUJITSU Customer Use Only

    FLASHWAVE 4570 Release 4.1

    Troubleshooting Manual3-13

    3.2.12 HP-TIM

    Alarm name HP-TIM

    Default severity Critical

    Alarm object SDH HP

    General information and causes The received path trace identifier does not match

    the expected value.

    Troubleshooting instructions

    1 Verify the expected path trace identifier is correct.

    2 If the alarm persists, contact the next higher level of technical support.

    3.2.13 HP-UNEQ

    Alarm name HP-UNEQ

    Default severity Critical

    Alarm object SDH HP

    General information and causes The VC-4, VC-4-Xc (X = 4, 16, 64) in the STM-N

    signal is not in use.

    Troubleshooting instructions

    1 Confirm or create the cross connection at the other side to be consistent with the localside.

    2 If the alarm persists, contact the next higher level of technical support.

    3.2.14 HP-Virtual_Concatenation_LOA

    Alarm name HP-Virtual_Concatenation_LOA

    Default severity Critical

    Alarm object HP VCG

    General information and causes The time between the first and last member of a

    Virtual Concatenation Group (VCG) to reach the

    local node is outside of the differential delay period.

    Troubleshooting instructions

    1 Check the SDH path for each VCG member to see which member passes through the

    most equipment or is taking the most time, and investigate an alternative connection

    route.

    2 If the alarm persists, contact the next higher level of technical support.

  • 8/10/2019 Troubleshooting Manual R4.1

    32/77

    CHAPTER 3Troubleshooting

    3-14FLASHWAVE 4570 Release 4.1

    Troubleshooting ManualFUJITSU and FUJITSU Customer Use Only

    FTDG-H750-D830

    Issue 1, August 2008

    3.2.15 HP-Virtual_Concatenation_LOM

    Alarm name HP-Virtual_Concatenation_LOM

    Default severity Critical

    Alarm object HP VCG member

    General information and causes One VCG member failed or was received at the

    local node with errors.

    Troubleshooting instructions

    1 Check VCG member for relevant terminal point alarms and correct them. Verify if HP-

    Virtual_Concatenation_LOM alarm still exists.

    2 Check performance monitoring for relevant VCG member terminal point for errors and

    correct them. Verify if HP-Virtual_Concatenation_LOM alarm still exists.

    3 If the alarm persists, contact the next higher level of technical support.

    3.2.16 HP-Virtual_Concatenation_TLCT

    Alarm name HP-Virtual_Concatenation_TLCT

    Default severity Critical

    Alarm object HP VCG

    General information and causes If both ends are in Link Capacity Adjustment

    Scheme (LCAS) mode, all TPs status is failure:

    The Terminal Point (TP) in the VCG has

    alarms;

    The sink TP receives the IDLE signal sent

    from the remote source TP.

    If both ends are in non-LCAS mode, any TP has

    the following alarms:

    AU-AIS

    AU-LOP

    HP-PLM

    HP-TIM

    HP-UNEQ

    HP-Virtual_Concatenation_LOM

    If the following VCG alarms occur: HP-Virtual_Concatenation_LOA

    HP-GFP_Loss_of_Frame_Delineation

    Troubleshooting instructions

    1 Verify the connection to the upstream equipment is normal.

    2 If the alarm persists, contact the next higher level of technical support.

  • 8/10/2019 Troubleshooting Manual R4.1

    33/77

    CHAPTER 3Troubleshooting

    FTDG-H750-D830

    Issue 1, August 2008FUJITSU and FUJITSU Customer Use Only

    FLASHWAVE 4570 Release 4.1

    Troubleshooting Manual3-15

    3.2.17 Link_Failure

    Alarm name Link_Failure

    Default severity Critical

    Alarm object Ethernet ports

    General information and causes The interconnecting cable contacts fail.

    The receiver fails in the indicated unit.

    The transmitter fails in the upstream equipment.

    Discontinuity of the intermediate cabling occurs.

    The erroneous routing of intermediate cabling

    occurs.

    The fiber type is incorrect.

    Troubleshooting instructions

    1 Verify the connections of the physical layer are correct.

    2 Verify the connectors are clean.

    3 Verify the fiber type is correct.

    4 If the alarm persists, contact the next higher level of technical support.

    3.2.18 Loss_of_Timing_Input

    Alarm name Loss_of_Timing_Input

    Default severity CriticalAlarm object HOCC card

    General information and causes No incoming signal is detected on the indicated

    station clock port.

    Troubleshooting instructions

    1 Verify the connections of the physical layer are correct.

    2 Verify the cables and connectors are not damaged.

    3 If the alarm persists, contact the next higher level of technical support.

  • 8/10/2019 Troubleshooting Manual R4.1

    34/77

    CHAPTER 3Troubleshooting

    3-16FLASHWAVE 4570 Release 4.1

    Troubleshooting ManualFUJITSU and FUJITSU Customer Use Only

    FTDG-H750-D830

    Issue 1, August 2008

    3.2.19 Loss_of_Timing_Output

    Alarm name Loss_of_Timing_Output

    Default severity Critical

    Alarm object HOCC card

    General information and causes The equipment related to timing output fails.

    Troubleshooting instructions

    1 Verify the synchronization configuration is correct.

    2 Verify the external timing input is normal.

    3 Change the local equipment using this timing output.

    4 If the alarm persists, contact the next higher level of technical support.

    3.2.20 LP-DEG

    Alarm name LP-DEG

    Default severity Minor

    Alarm object SDH LP

    General information and causes The bit error ratio in the LP has exceeded the

    provisioned LP Degrade Threshold. The quality

    of the transmission signal is degraded.

    This error is caused by fault(s) in upstream

    external cabling or equipment.

    Troubleshooting instructions

    1 Verify the upstream external cabling and equipment.

    2 Verify the threshold in the management system.

    3 If the alarm persists, contact the next higher level of technical support.

    3.2.21 LP-EXC

    Alarm name LP-EXC

    Default severity Major

    Alarm object SDH LP

    General information and causes The bit error ratio in the LP has exceeded the

    provisioned LP Excessive Error Threshold. The

    quality of the transmission signal is degraded.

    This error is caused by fault(s) in upstream

    external cabling or equipment.

    Troubleshooting instructions

    1 Verify upstream external cabling and equipment.

    2 If the alarm persists, contact the next higher level of technical support.

  • 8/10/2019 Troubleshooting Manual R4.1

    35/77

    CHAPTER 3Troubleshooting

    FTDG-H750-D830

    Issue 1, August 2008FUJITSU and FUJITSU Customer Use Only

    FLASHWAVE 4570 Release 4.1

    Troubleshooting Manual3-17

    3.2.22 LP-GFP_Customer_Signal_Failure

    Alarm name LP-GFP_Customer_Signal_Failure

    Default severity Critical

    Alarm object Ethernet WAN ports

    General information and causes The upstream LAN port connectivity is down.

    Troubleshooting instructions

    1 Verify the upstream external cabling and equipment are normal.

    2 If the alarm persists, contact the next higher level of technical support.

    3.2.23 LP-GFP_Loss_of_Frame_Delineation

    Alarm name LP-GFP_Loss_of_Frame_Delineation

    Default severity Critical

    Alarm object Ethernet WAN ports

    General information and causes The upstream Ethernet signal fails because of GFP

    synchronization failure.

    Troubleshooting instructions

    1 Verify the upstream connection and equipment are normal.

    2 If the alarm persists, contact the next higher level of technical support.

    3.2.24 LP-PLM

    Alarm name LP-PLM

    Default severity Major

    Alarm object SDH LP

    General information and causes Mapping mode of local and far-end NEs is not

    same.

    Expected payload value set via the TP

    Configuration window of the LCT system inlocal node is not the same as the actual payload

    value in far-end node.

    Troubleshooting instructions

    1 Verify the traffic structure of the local node is the same as the far-end node.

    2 Change the expected traffic type in the TP Configuration window of the local node LCT

    to match the actual payload value in far-end node.

    3 If the alarm persists, contact the next higher level of technical support.

  • 8/10/2019 Troubleshooting Manual R4.1

    36/77

    CHAPTER 3Troubleshooting

    3-18FLASHWAVE 4570 Release 4.1

    Troubleshooting ManualFUJITSU and FUJITSU Customer Use Only

    FTDG-H750-D830

    Issue 1, August 2008

    3.2.25 LP-RDI

    Alarm name LP-RDI

    Default severity Minor

    Alarm object SDH LP

    General information and causes The downstream far end station of the node

    that reported the alarm detects a malfunction

    at its receiving side: Tributary Unit Alarm

    Indication Signal received (TU-AIS).

    Troubleshooting instructions

    1 No alarms in the reporting node. React on the far-end alarms. Follow the clearing

    actions for those alarm(s).

    2 If the alarm persists, contact the next higher level of technical support.

    3.2.26 LP-RFI

    Alarm name LP-RFI

    Default severity Minor

    Alarm object SDH LP

    General information and causes The downstream far end station of the node that

    reported the alarm detects a malfunction at its

    receiving side: VC-12 byte synchronous path RemoteFailure.

    Troubleshooting instructions

    1 No alarms in the reporting node. React on the far-end alarms. Follow the clearing

    actions for those alarm(s).

    2 If the alarm persists, contact the next higher level of technical support.

    3.2.27 LP-TIM

    Alarm name LP-TIM

    Default severity Critical

    Alarm object SDH LP

    General information and causes A provisioned trace string inserted in a VC-12 path

    was not received or was received corrupted, due to

    wrong configuration, hardware failures, or

    transmission failures. Mismatch between received

    trace ID and expected trace ID.

    Troubleshooting instructions

    1 Verify cross-connections.2 Verify tributary cables and tributary units.

  • 8/10/2019 Troubleshooting Manual R4.1

    37/77

    CHAPTER 3Troubleshooting

    FTDG-H750-D830

    Issue 1, August 2008FUJITSU and FUJITSU Customer Use Only

    FLASHWAVE 4570 Release 4.1

    Troubleshooting Manual3-19

    3 Verify the expected trace in the management system.

    4 If the alarm persists, contact the next higher level of technical support.

    3.2.28 LP-UNEQ

    Alarm name LP-UNEQ

    Default severity Critical

    Alarm object SDH LP

    General information and causes Lower order path in STM-N signal is not in use.

    Troubleshooting instructions

    1 Confirm or create the cross connection settings at the remote side to be consistent with

    the local side.

    2 If the alarm persists, contact the next higher level of technical support.

    When defining or changing a cross-connection this alarm will almost inevitably come up

    as it is practically impossible to issue the changes at both sides at the same moment.

    The LP-UNEQ can not be reported from 126 E1 (W/P) cards monitored ports if there is no

    cross connect card equipped in NE.

    3.2.29 LP-Virtual_Concatenation_LOA

    Alarm name LP-Virtual_Concatenation_LOA

    Default severity Critical

    Alarm object LP VCG

    General information and causes The time between the first and last member of a

    VCG group to reach the local node is outside of the

    differential delay period.

    Troubleshooting instructions

    1 Check the SDH path for each VCG member to see which member passes through the

    most equipment or is taking the most time, and investigate an alternative connectionroute.

    2 If the alarm persists, contact the next higher level of technical support.

    3.2.30 LP-Virtual_Concatenation_LOM

    Alarm name LP-Virtual_Concatenation_LOM

    Default severity Critical

    Alarm object LP VCG member

    General information and causes One VCG member failed or was received at the

    local node with errors.

    i

    !!

    Warning

  • 8/10/2019 Troubleshooting Manual R4.1

    38/77

    CHAPTER 3Troubleshooting

    3-20FLASHWAVE 4570 Release 4.1

    Troubleshooting ManualFUJITSU and FUJITSU Customer Use Only

    FTDG-H750-D830

    Issue 1, August 2008

    Troubleshooting instructions

    1 Check VCG member for relevant terminal point alarms and correct them. Verify if LP-

    Virtual_Concatenation_LOM alarm still exists.2 Check performance monitoring for relevant VCG member terminal point for errors and

    correct them. Verify if LP-Virtual_Concatenation_LOM alarm still exists.

    3 3 If the alarm persists, contact the next higher level of technical support.

    3.2.31 LP-Virtual_Concatenation_TLCT

    Alarm name LP-Virtual_Concatenation_TLCT

    Default severity Critical

    Alarm object LP VCG

    General information and causes If both ends are in LCAS mode, all TPs status

    is failure:

    The TP in the VCG has alarms;

    The sink TP receives the IDLE signal sent

    from the remote source TP.

    If both ends are in non-LCAS mode, any TP has

    the following alarms:

    AU-AIS

    AU-LOP

    TU-AIS

    TU-LOP

    HP-PLM

    HP-TIM HP-UNEQ

    HP-Virtual_Concatenation_LOM

    LP-PLM

    LP-TIM

    LP-UNEQ

    LP-Virtual_Concatenation_LOM

    If the following VCG alarms occur:

    HP-Virtual_Concatenation_LOA

    HP-GFP_Loss_of_Frame_Delineation

    LP-Virtual_Concatenation_LOA

    LP-GFP_Loss_of_Frame_Delineation

    Troubleshooting instructions

    1 Verify connection to the upstream equipment.

    2 If the alarm persists, contact the next higher level of technical support.

  • 8/10/2019 Troubleshooting Manual R4.1

    39/77

    CHAPTER 3Troubleshooting

    FTDG-H750-D830

    Issue 1, August 2008FUJITSU and FUJITSU Customer Use Only

    FLASHWAVE 4570 Release 4.1

    Troubleshooting Manual3-21

    3.2.32 MS_AIS

    Alarm name MS_AIS

    Default severity Minor

    Alarm object SDH MS

    General information and causes An AISsignal is inserted in the upstream NE.

    Troubleshooting instructions

    1 Clear the upstream inserted AIS signal.

    2 If the alarm persists, contact the next higher level of technical support.

    3.2.33 MS-DCC_Connection_Failure

    Alarm name MS-DCC_Connection_Failure

    Default severity Major

    Alarm object SDH MS

    General information and causes MS-DCC is disabled at one side of the MS DCC

    link.

    Troubleshooting instructions

    1 Verify the MS-DCC is enabled and working normally at both ends of the MS DCC link.

    2 If the alarm persists, contact the next higher level of technical support.

    3.2.34 MS_DEG

    Alarm name MS_DEG

    Default severity Minor

    Alarm object SDH MS

    General information and causes A degraded signal defect is detected when the

    equivalent BER exceeds a preset threshold of 10-x, x

    = 5, 6, 7, 8, 9.

    Troubleshooting instructions

    1 Verify the upstream external cabling and equipment are normal.

    2 Verify the threshold is set correctly.

    3 If the alarm persists, contact the next higher level of technical support.

  • 8/10/2019 Troubleshooting Manual R4.1

    40/77

    CHAPTER 3Troubleshooting

    3-22FLASHWAVE 4570 Release 4.1

    Troubleshooting ManualFUJITSU and FUJITSU Customer Use Only

    FTDG-H750-D830

    Issue 1, August 2008

    3.2.35 MS_EXC

    Alarm name MS_EXC

    Default severity Major

    Alarm object SDH MS

    General information and causes An excessive error defect is detected when the

    equivalent BER exceeds a preset threshold of 10-x, x

    = 3, 4, 5.

    Troubleshooting instructions

    1 Verify the upstream external cabling and equipment are normal.

    2 Verify the threshold is set correctly.

    3 If the alarm persists, contact the next higher level of technical support.

    3.2.36 MS-K1/K2_Mismatch

    Alarm name MS-K1/K2_Mismatch

    Default severity Major

    Alarm object SDH MS

    General information and causes The protection switching is not successful.

    Troubleshooting instructions1 Verify the conditions of protection switching are normal.

    2 If the alarm persists, contact the next higher level of technical support.

    3.2.37 MS_RDI

    Alarm name MS_RDI

    Default severity Minor

    Alarm object SDH MS

    General information and causes The downstream NE receives the malfunctioningsignal:

    MS-AIS

    RS-LOF

    RS-TIM

    SPI-LOS

    The following situations occur in the far-end station:

    No signal received

    AIS signal received

    Excessive error rate

    Troubleshooting instructions

    1 Verify the upstream external cabling and equipment are normal.

  • 8/10/2019 Troubleshooting Manual R4.1

    41/77

    CHAPTER 3Troubleshooting

    FTDG-H750-D830

    Issue 1, August 2008FUJITSU and FUJITSU Customer Use Only

    FLASHWAVE 4570 Release 4.1

    Troubleshooting Manual3-23

    2 Verity the local transmitting equipment is working normally.

    3 Clear the indicated faults in the far-end node.

    4 If the alarm persists, contact the next higher level of technical support.

    3.2.38 OA_Gain_High

    Alarm name OA_Gain_High

    Default severity Major

    Alarm object OA ports

    General information and causes 20 dB Pre-Optical Amplifier (POA): Gain > 21

    dB

    13 dBm Booster Optical Amplifier (BOA): Gain >

    19 Db 15 dBm BOA: Gain > 21 dB

    18 dBm BOA: Gain > 24 dB

    Troubleshooting instructions

    1 Verify the output power of the OA is set properly.

    2 Verity the input power of the OA is normal.

    3 If the alarm persists, contact the next higher level of technical support.

    3.2.39 OA_Input_LOS

    Alarm name OA_Input_LOS

    Default severity Critical

    Alarm object OA ports

    General information and causes The cable ruptures.

    The optical connector is dirty.

    The input optical power is below the pre-defined

    power threshold.

    Troubleshooting instructions

    1 Verify the connections of the physical layer are correct.

    2 Verity the operation of the transmitter in the far-end station is normal.

    3 Verify the cables and connectors are not damaged.

    4 Verify the pre-defined input power threshold is proper.

    5 If the alarm persists, contact the next higher level of technical support.

  • 8/10/2019 Troubleshooting Manual R4.1

    42/77

    CHAPTER 3Troubleshooting

    3-24FLASHWAVE 4570 Release 4.1

    Troubleshooting ManualFUJITSU and FUJITSU Customer Use Only

    FTDG-H750-D830

    Issue 1, August 2008

    3.2.40 OA_Output_LOS

    Alarm name OA_Output_LOS

    Default severity Critical

    Alarm object OA ports

    General information and causes The local transmitting module fails.

    The output optical power is below the pre-

    defined power threshold.

    Troubleshooting instructions

    1 Verify the local transmitting module is normal.

    2 Verify the pre-defined output power threshold is proper.

    3 If the alarm persists, contact the next higher level of technical support.

    3.2.41 OA_Output_Power_High

    Alarm name OA_Output_Power_High

    Default severity Major

    Alarm object OA ports

    General information and causes 20 dB POA: Output power > -9 dBm

    13 dBm BOA: Output power > 14 dBm

    15 dBm BOA: Output power > 16 dBm

    18 dBm BOA: Output power > 19 dBm

    Troubleshooting instructions

    1 Verify the gain of the OA is set properly.

    2 Verify the input power of the OA is proper.

    3 If the alarm persists, contact the next higher level of technical support.

    3.2.42 PPI-AIS

    Alarm name PPI-AIS

    Default severity Minor

    Alarm object Port

    General information and causes In one of the upstream nodes a defect is detected

    and led to the insertion of the alarm indication

    signal.

    Troubleshooting instructions

    1 Verify the upstream external cabling and equipment.

    2 If the alarm persists, contact the next higher level of technical support.

  • 8/10/2019 Troubleshooting Manual R4.1

    43/77

    CHAPTER 3Troubleshooting

    FTDG-H750-D830

    Issue 1, August 2008FUJITSU and FUJITSU Customer Use Only

    FLASHWAVE 4570 Release 4.1

    Troubleshooting Manual3-25

    3.2.43 PPI-LOF

    Alarm name PPI-LOF

    Default severity Critical

    Alarm object PDH Port

    General information and causes Alignment to the frame structure of the received

    E1/E3/DS3 signal is not possible.

    Troubleshooting instructions

    1 Verify operation of the transmitter in the far-end station.

    2 If the alarm persists, contact the next higher level of technical support.

    3.2.44 PPI-LOM

    Alarm name PPI-LOM

    Default severity Critical

    Alarm object PDH Port

    General information and causes Alignment to the Cyclic Redundancy Check (CRC)

    Multiframe structure of the received E1 signal is not

    possible.

    Troubleshooting instructions

    1 Verify operation of the transmitter in the far-end station.

    2 If the alarm persists, contact the next higher level of technical support.

    3.2.45 PPI-LOS

    Alarm name PPI-LOS

    Default severity Critical

    Alarm object PDH Port

    General information and causes Interconnecting cabling contacts have a

    problem. Receiver fault in indicated tributary unit.

    Transmitter fault in the upstream equipment (not

    the Transmission System).

    Discontinuity in the intermediate cabling.

    Erroneous routing of intermediate cabling.

    Troubleshooting instructions

    1 Verify the connections of the physical layer.

    2 Verify for cable breaks or dirty connectors (measure it with power meter and clear it).

    3 If the alarm persists, contact the next higher level of technical support.

  • 8/10/2019 Troubleshooting Manual R4.1

    44/77

    CHAPTER 3Troubleshooting

    3-26FLASHWAVE 4570 Release 4.1

    Troubleshooting ManualFUJITSU and FUJITSU Customer Use Only

    FTDG-H750-D830

    Issue 1, August 2008

    3.2.46 PPI-RDI

    Alarm name PPI-RDI

    Default severity Minor

    Alarm object PDH Port

    General information and causes When an alarm from the local node is transmitted to

    the remote (far-end) node, the far end node will

    send this alarm back.

    Troubleshooting instructions

    1 Verify operation of the transmitter in the local station.

    2 If the alarm persists, contact the next higher level of technical support.

    3.2.47 RPR-Exceed_Max_Stations

    Alarm name RPR-Exceed_Max_Stations

    Default severity Critical

    Alarm object RPRCard

    General information and causes Number of stations in the RPR ring exceeds 32.

    Troubleshooting instructions

    1 Remove stations which exceed the maximum limit of 32.2 If the alarm persists, contact the next higher level of technical support.

    3.2.48 RPR-Link_Failure_East

    Alarm name RPR-Link_Failure_East

    Default severity Critical

    Alarm object RPR Card

    General information and causes The east RPR links keep alive detection has timed

    out.

    Troubleshooting instructions

    1 Verify that the optical fiber or the SDH cross-connection used for the east RPR path is

    normal.

    2 If the alarm persists, contact the next higher level of technical support.

  • 8/10/2019 Troubleshooting Manual R4.1

    45/77

    CHAPTER 3Troubleshooting

    FTDG-H750-D830

    Issue 1, August 2008FUJITSU and FUJITSU Customer Use Only

    FLASHWAVE 4570 Release 4.1

    Troubleshooting Manual3-27

    3.2.49 RPR-Link_Failure_West

    Alarm name RPR-Link_Failure_West

    Default severity Critical

    Alarm object RPR Card

    General information and causes The west RPR links keep alive detection has timed

    out.

    Troubleshooting instructions

    1 Verify that the optical fiber or the SDH cross-connection used for the west RPR path is

    normal.

    2 If the alarm persists, contact the next higher level of technical support.

    3.2.50 RPR-Miscabling_East

    Alarm name RPR-Miscabling_East

    Default severity Critical

    Alarm object RPR Card

    General information and causes The east link of one RPR station is wrongly

    connected to the same side (east link) of another

    RPR station.

    Troubleshooting instructions

    1 Re-configure the RPR link direction of one of the links, either local or far end, to make

    sure the west (east) link connects to the east (west) link. Ensure this change is

    consistent with the rest of the topology structure.

    2 If the alarm persists, contact the next higher level of technical support.

    3.2.51 RPR-Miscabling_West

    Alarm name RPR-Miscabling_West

    Default severity CriticalAlarm object RPR Card

    General information and causes The west link of one RPR station is wrongly

    connected to the same side (west link) of another

    RPR station.

    Troubleshooting instructions

    1 Re-configure the RPR link direction of one of the links, either local or far end, to make

    sure the west (east) link connects to the east (west) link. Ensure this change is

    consistent with the rest of the topology structure.

    2 If the alarm persists, contact the next higher level of technical support.

  • 8/10/2019 Troubleshooting Manual R4.1

    46/77

    CHAPTER 3Troubleshooting

    3-28FLASHWAVE 4570 Release 4.1

    Troubleshooting ManualFUJITSU and FUJITSU Customer Use Only

    FTDG-H750-D830

    Issue 1, August 2008

    3.2.52 RPR-Protection_Misconfig

    Alarm name RPR-Protection_Misconfig

    Default severity Critical

    Alarm object RPR Card

    General information and causes At least one stations protection mode is different

    from other stations.

    Troubleshooting instructions

    1 Verify the protection mode in all of the RPR stations of the ring is the same. If not, re-

    configure the protection mode to be the same.

    2 If the alarm persists, contact the next higher level of technical support.

    3.2.53 RPR-Ringlet0_ReservedA0_Exceeding

    Alarm name RPR-Ringlet0_ReservedA0_Exceeding

    Default severity Major

    Alarm object RPR Card

    General information and causes A0 bandwidth reserved on RPR ringlet0 exceeds

    the link rate.

    Troubleshooting instructions

    1 Re-configure the A0 bandwidth reserved on RPR ringlet0 and make sure not to exceed

    the available link rate.

    2 If the alarm persists, contact the next higher level of technical support.

    3.2.54 RPR-Ringlet1_ReservedA0_Exceeding

    Alarm name RPR-Ringlet1_ReservedA0_Exceeding

    Default severity Major

    Alarm object RPR Card

    General information and causes A0 bandwidth reserved on RPR ringlet1 exceeds

    the link rate.

    Troubleshooting instructions

    1 Re-configure the A0 bandwidth reserved on RPR ringlet1 and make sure not to exceed

    the available link rate.

    2 If the alarm persists, contact the next higher level of technical support.

  • 8/10/2019 Troubleshooting Manual R4.1

    47/77

    CHAPTER 3Troubleshooting

    FTDG-H750-D830

    Issue 1, August 2008FUJITSU and FUJITSU Customer Use Only

    FLASHWAVE 4570 Release 4.1

    Troubleshooting Manual3-29

    3.2.55 RPR-Topology_Inconsistent

    Alarm name RPR-Topology_Inconsistent

    Default severity Critical

    Alarm object RPR Card

    General information and causes Inconsistent topology of the RPR ring is usually

    caused by the duplicate Media Access Control

    (MAC) addresses.

    Troubleshooting instructions

    1 Re-configure the duplicated RPR stations MAC address.

    2 If the alarm persists, contact the next higher level of technical support.

    3.2.56 RPR-Topology_Instability

    Alarm name RPR-Topology_Instability

    Default severity Critical

    Alarm object RPR Card

    General information and causes Topology instability is caused by the topology not

    being discovered correctly, because of reasons

    such as the incorrect configuration of RPR links

    and stations.

    Troubleshooting instructions

    1 Re-configure the RPR networks topology (such as the Cross Connection (CC), the WAN

    port trigger, the optical link, etc.) and make sure the configuration is correct.

    2 If the alarm persists, contact the next higher level of technical support.

    3.2.57 RS-DCC_Connection_Failure

    Alarm name RS-DCC_Connection_Failure

    Default severity MajorAlarm object SDH RS

    General information and causes RS-DCC is disabled at one side of the RS DCC link.

    Troubleshooting instructions

    1 Verify the RS-DCC is enabled and working normally at both ends of the RS DCC link.

    2 If the alarm persists, contact the next higher level of technical support.

  • 8/10/2019 Troubleshooting Manual R4.1

    48/77

    CHAPTER 3Troubleshooting

    3-30FLASHWAVE 4570 Release 4.1

    Troubleshooting ManualFUJITSU and FUJITSU Customer Use Only

    FTDG-H750-D830

    Issue 1, August 2008

    3.2.58 RS_DEG

    Alarm name RS-DEG

    Default severity Minor

    Alarm object SDH RS

    General information and causes A degraded signal defect is detected when the

    equivalent BER exceeds a preset threshold of 10-x,

    x = 6, 7, 8, 9.

    Troubleshooting instructions

    1 Verify the upstream external cabling and equipment are normal.

    2 Verify the threshold is set correctly.

    3 If the alarm persists, contact the next higher level of technical support.

    3.2.59 RS_EXC

    Alarm name RS_EXC

    Default severity Major

    Alarm object SDH RS

    General information and causes An excessive error defect is detected when the

    equivalent BER exceeds a preset threshold of 10-5

    .

    Troubleshooting instructions

    1 Verify the upstream external cabling and equipment are normal.

    2 If the alarm persists, contact the next higher level of technical support.

    3.2.60 RS_LOF

    Alarm name RS_LOF

    Default severity Critical

    Alarm object SDH RS

    General information and causes The received signal does not match the port rate.

    The received signal of the SDH section overhead

    is not correctly structured.

    The port input level (dBm) is too high or too low.

    The fiber type is wrong.

    Troubleshooting instructions

    1 Verify the intermediate fiber is normal.

    2 Verify the connectors are clean.

    3 Loop the signal from the transmitter to the receiver. Verify no LOF fault is reported.

    4 Verify the port signal level is proper.

  • 8/10/2019 Troubleshooting Manual R4.1

    49/77

    CHAPTER 3Troubleshooting

    FTDG-H750-D830

    Issue 1, August 2008FUJITSU and FUJITSU Customer Use Only

    FLASHWAVE 4570 Release 4.1

    Troubleshooting Manual3-31

    5 Verify the transmitter in the far-end is normal.

    6 If the alarm persists, contact the next higher level of technical support.

    3.2.61 RS_TIM

    Alarm name RS_TIM

    Default severity Critical

    Alarm object SDH RS

    General information and causes Incorrect routing occurs in the network due to:

    Incorrectly connected line cables. An improper

    expected trace identifier.

    Troubleshooting instructions

    1 Verify the line cables are connected correctly by interpreting the received STM-N RS

    trace identifiers.

    2 Verify the expected RS trace identifier is correct.

    3 If the alarm persists, contact the next higher level of technical support.

    3.2.62 SPI_LOS

    Alarm name SPI_LOS

    Default severity CriticalAlarm object SDH SPI

    General information and causes The fiber ruptures.

    The optical connectors are dirty.

    The upstream far-end station fails.

    Troubleshooting instructions

    1 Verify the connections of the physical layer are correct.

    2 Verify the operation of the transmitter in the far-end station is normal.

    3 Verify the connectors are clean.

    4 If the alarm persists, contact the next higher level of technical support.

  • 8/10/2019 Troubleshooting Manual R4.1

    50/77

    CHAPTER 3Troubleshooting

    3-32FLASHWAVE 4570 Release 4.1

    Troubleshooting ManualFUJITSU and FUJITSU Customer Use Only

    FTDG-H750-D830

    Issue 1, August 2008

    3.2.63 Synchronization_Signal_Message_Mismatch

    Alarm name Synchronization_Signal_Message_Mismatch

    Default severity Major

    Alarm object HOCC card

    General information and causes The SSMbyte is invalid.

    Troubleshooting instructions

    1 Verify the SSM byte value is a legal value.

    2 If the alarm persists, contact the next higher level of technical support.

    3.2.64 System_Clock_Holdover_Longer

    Alarm name System_Clock_Holdover_Longer

    Default severity Warning

    Alarm object HOCC card

    General information and causes The system clock is running in the holdover mode

    and the holdover time is longer than 24 hours.

    Troubleshooting instructions

    1 Repair the failed timing reference.

    2 Re-lock the system clock to a valid timing reference.

    3 If the alarm persists, contact the next higher level of technical support.

    3.2.65 System_Clock_Unlocked

    Alarm name System_Clock_Unlocked

    Default severity Major

    Alarm object HOCC card

    General information and causes All selected timing references are lost or have

    failed.

    The system clock mode has been changed from

    the locked mode to the holdover or free-running

    mode manually.

    Troubleshooting instructions

    1 Verify the selected timing reference works normally.

    2 Re-select a valid timing reference.

    3 Set the system clock working mode as locked

    4 If the alarm persists, contact the next higher level of technical support.

  • 8/10/2019 Troubleshooting Manual R4.1

    51/77

    CHAPTER 3Troubleshooting

    FTDG-H750-D830

    Issue 1, August 2008FUJITSU and FUJITSU Customer Use Only

    FLASHWAVE 4570 Release 4.1

    Troubleshooting Manual3-33

    3.2.66 Timing_Reference_Degrade

    Alarm name Timing_Reference_Degrade

    Default severity Minor

    Alarm object Input clock reference

    General information and causes The frequency offset of the timing source is out

    of range.

    The phase change of the timing source is

    abnormal.

    Troubleshooting instructions

    1 Verify the upstream related equipment is working normally.

    2 Verify the local timing input equipment is working normally.3 If the alarm persists, contact the next higher level of technical support.

    3.2.67 Timing_Reference_Failure

    Alarm name Timing_Reference_Failure

    Default severity Major

    Alarm object Input clock reference

    General information and causes The reference clock f