Page 1: TRITON IMAGING, INC. C3D Hardware January 2011. Hardware Configuration Options There are two different configuration options for the C3D: 1. towed 2

TRITON IMAGING, INC.TRITON IMAGING, INC.

C3D HardwareJanuary 2011

Page 2: TRITON IMAGING, INC. C3D Hardware January 2011. Hardware Configuration Options There are two different configuration options for the C3D: 1. towed 2

Hardware Configuration Hardware Configuration OptionsOptions

There are two different configuration options for the C3D:

1. towed

2. mounted (pole or hull

mounted)

This guide will focus on the mounted setup option

Page 3: TRITON IMAGING, INC. C3D Hardware January 2011. Hardware Configuration Options There are two different configuration options for the C3D: 1. towed 2

Pole-Mounted Hardware Pole-Mounted Hardware ConfigurationConfiguration

This includes plugging in hardware components and configuration of the GPS, Benthos DSP and acquisition PC

Page 4: TRITON IMAGING, INC. C3D Hardware January 2011. Hardware Configuration Options There are two different configuration options for the C3D: 1. towed 2

Hardware Setup – Benthos C3DHardware Setup – Benthos C3D

Attach port and starboard C3D transducer cables to port and starboard C3D transducers

Attach port and starboard C3D transducer cables to port and starboard connectors on C3D DSP

Connect Ethernet cable from DSP to PC

Page 5: TRITON IMAGING, INC. C3D Hardware January 2011. Hardware Configuration Options There are two different configuration options for the C3D: 1. towed 2

Hardware Setup – CDL GyroHardware Setup – CDL Gyro

Attach the power and communication cable to the ‘Umbilical’ port on the CDL MiniRLG2 and the other ends to:

24V DC power supply (red/black wires)

RS-232 port below the AUX port used for altimeter input, near PWR input

Page 6: TRITON IMAGING, INC. C3D Hardware January 2011. Hardware Configuration Options There are two different configuration options for the C3D: 1. towed 2

Hardware Setup – Hemisphere GPSHardware Setup – Hemisphere GPS

Attach Hemisphere GPS antenna BNC cable to the Antenna port on the Hemisphere GPS receiver

Attach a RS-232 serial cable to the GPS receiver and the other end to the 4-port RS-232 GPS splitter

Attach a GPS input cable from the GPS Splitter to the AUX2/GPS port on the CDL MiniRLG2

Attach a GPS input cable from the GPS Splitter to COM 4 on the PC

Attach the 24V DC power supply to the GPS Receiver power port

Page 7: TRITON IMAGING, INC. C3D Hardware January 2011. Hardware Configuration Options There are two different configuration options for the C3D: 1. towed 2

Hardware Setup – Tritech AltimeterHardware Setup – Tritech AltimeterInstall Tritech altimeter into tail cone of C3D transducer pod:

- Adjust height of altimeter - Tighten set screws

Attach Tritech altimeter cable to the altimeter.

Attach the Tritech altimeter cable to the C3D DSP port labeled AUX

Connect RS232 cable from the C3D DSP to PC serial port COM2.

Page 8: TRITON IMAGING, INC. C3D Hardware January 2011. Hardware Configuration Options There are two different configuration options for the C3D: 1. towed 2

Hardware Setup – Odom Digibar-VHardware Setup – Odom Digibar-V

Install Odom Digibar SVS onto mounting plate

Attach the Odom Digibar SVS cable to the SVS and the other end to the Odom Digibar-V topside port labeled Digibar Probe

Attach the supplied USB cable to the Odom Digibar-V topside port labeled USB and the other end to any available USB port on the acquisition PC, this supplies power to the SVS and also communication from the SVS to the PC, as COM 5

Page 9: TRITON IMAGING, INC. C3D Hardware January 2011. Hardware Configuration Options There are two different configuration options for the C3D: 1. towed 2

PC Network SettingsPC Network SettingsThe Benthos C3D sonar connects to Isis via an Ethernet connection. The default IP address of the C3D sonar is 192.168.0.40.

1.You need to configure the network card on the system that is running Isis to be in the same IP range, in the example we have chosen 192.168.0.39 (you must not use 192.168.0.40)

2.Open local area connections and select Properties for TCP/IP as shown below to the left.

3.Enter an address in the same range as the sonar as shown below to the right

Page 10: TRITON IMAGING, INC. C3D Hardware January 2011. Hardware Configuration Options There are two different configuration options for the C3D: 1. towed 2

SVS Network SettingsSVS Network Settings

Page 11: TRITON IMAGING, INC. C3D Hardware January 2011. Hardware Configuration Options There are two different configuration options for the C3D: 1. towed 2

SVS Network SettingsSVS Network Settings1. First , turn on the Odom Digibar by pressing the Power button (will light

red when powered)

2. On acquisition PC, open udp-serial-gui.exe

3. Select the Profile button, followed by Load button, to Load SVS.Conf configuration file

4. Navigate to the SVS.Conf file, select it, and press the Open button, to load for configuration of the udp-serial-gui software

5. Select the Connect button to connect the serial SV sensor for UDP output

6. Select the Serial Device button to verify correct com port (COM 5 for first USB serial device), baud rate (19200 for Odom Digibar) and protocol (8, None, 1, Off)

7. Select the Network button to verify the correct input (no choice) /output network IP addresses (192.168.0.39 and 192.168.0.40), UDP ports (4201, 4301), and hex-code line-feed (%OD) and carriage return (%OA) options are applied for output to the C3D

8. Select the Data button, to verify the SVS data are coming through and are correct (in air the digibar may read values below 1350m/s, however the C3D will not accept SV data below 1350m/s and the default value of 1500m/s will be displayed and used by C3D, until valid data are available - when the unit is submerged and reading sound velocity in water)

9. When done, minimize (DO NOT CLOSE) the udp-serial-gui program

10. Verify by opening the C3D Control Panel, under Utility tab select the Edit Server Configuration button, verify that the telemetry device SVS only /UDP/4301 line is enabled (meaning that corresponding line does not start with #) and verify the UDP port 4301 for receiving SV data from Serial to UDP software

Page 12: TRITON IMAGING, INC. C3D Hardware January 2011. Hardware Configuration Options There are two different configuration options for the C3D: 1. towed 2

Altimeter, GPS Altimeter, GPS && CDL Settings CDL Settings

Page 13: TRITON IMAGING, INC. C3D Hardware January 2011. Hardware Configuration Options There are two different configuration options for the C3D: 1. towed 2

Altimeter, GPS Altimeter, GPS && CDL Settings CDL SettingsTritech Altimeter:

1. From the C3D Control Panel on the acquisition PC, under Utility tab, select the Edit Server Configuration button

2. Set the Altimeter data to output on a RS232 port (9600, 8, N, 1)

Hemisphere GPS:

1. Turn on the 24V power supply for the GPS Receiver

2. Press the button on the GPS Receiver

3. Configure the GPS Receiver to output the following data strings: GGA, VTG, GPA, ZDA,

CDL RLGMini2:

1. Verify the 24V power supply for the CDL gyro is on

2. Open the C3D Control Panel, under Utility tab select the Edit Server Configuration button, verify that:

• 38400, (for CDL MiniRLG2 baud rate) • timestamp • device /dev/ttyS0 • output 192.168.0.39:4101 • output 192.168.0.39:4111

3. If changes are made, select the Save Config button to save changes

Page 14: TRITON IMAGING, INC. C3D Hardware January 2011. Hardware Configuration Options There are two different configuration options for the C3D: 1. towed 2

C3D Sonar Settings C3D Sonar Settings (page 1)(page 1)1. Return to the C3D Control Panel, Utility tab menu and select C3D Diagnostic

Utility button

2. Follow the procedure "Calibrating the C3D Receivers" outlined in the C3D manual, also provided as a *.pdf file, for quick reference on desktop

3. Select the Exit Display button to close the Diagnostic (Display) Utility program

4. Start Triton Isis (see Section 3.0 for configuration details)

5. Select appropriate water depth range of survey operation (usually 5xAltitude)

6. Tune the sidescan gain

7. From C3D Control Panel, under Utility tab, select the Sonar Parameters button

8. Verify the declination angle matches that of the C3D transducers (lowest orientation has 2 bolt holes exposed above transducer, is 40 degrees; highest orientation, 0 bolt holes exposed above transducer, is 20 degrees)

9. If the declination angle needed change, select Update Realtime and verify the result in Triton Isis bathymetry display, then select the Save button, near Profile, to save to the default range.cfg profile

10. Adjust the Amplitude threshold (toward 1 to reduce multipath and poor accuracy data in far- and near-field ranges and water column, or toward 0 to increase swath width and allow lower amplitude echoes to be mapped), after each change, select Update Realtime and verify results in Triton Isis bathymetry display

Page 15: TRITON IMAGING, INC. C3D Hardware January 2011. Hardware Configuration Options There are two different configuration options for the C3D: 1. towed 2

C3D Sonar Settings C3D Sonar Settings (page 2)(page 2)1. Adjust the Unit Circle threshold (toward 0 to reduce mulitpath and poor

accuracy data in far- and near-field ranges and water column, or toward 1 to increase data resolution and allow greater variability in the angle of arrival from echoes to be mapped), after each change, select Update Realtime and verify results in Triton Isis bathymetry display, verify results in triton Isis Bathymetry display

2. Adjust the Bottom Tracking threshold (toward 1 to reduce multipath and poor accuracy data in far- and near-field ranges and water column, or toward 4 to increase data resolution and allow greater tolerance for distance between neighboring echoes to be mapped), after each change, select Update Realtime and verify results in Triton Isis bathymetry display

3. Select the Update Realtime button and verify the result in Triton Isis bathymetry display, then select the Save button to save to the default range.cfg profile

4. Edit the Default Profile name to generate a new profile and save the new threshold settings to the custom profile, after changing the name from default to a name of choice, select the Save button to save the current settings

5. Select drop-down triangle at right of the profile name and change back to default

6. Select the Save button, to save the current settings to the default profile

7. <<Note: If C3D range is changed, repeat steps B.24-35>>

Page 16: TRITON IMAGING, INC. C3D Hardware January 2011. Hardware Configuration Options There are two different configuration options for the C3D: 1. towed 2

Once the hardware is configured and the data is coming into the acquisition PC, Isis needs to be setup to receive all the different data streams. For this example, the following data streams need to be configured:

1. C3D data – Ethernet port

2. Motion data (roll, pitch, heave, heading) – UDP

3. Epoch Time - UDP

4. Altimeter – RS232

5. GPS – RS232

6. SVS – UDP

Triton Isis ConfigurationTriton Isis Configuration

C3DEthernet

Motion/EpochUDP

AcquisitionPC

GPSRS232COM4

SVSUSBCOM5

ALTRS232COM2

Page 17: TRITON IMAGING, INC. C3D Hardware January 2011. Hardware Configuration Options There are two different configuration options for the C3D: 1. towed 2

Isis Configuration – C3D DataIsis Configuration – C3D Data (page 1) (page 1)

To configure the C3D sonar, start Isis and select the ‘Record Setup’ option from the drop-down menu:

This will launch the ‘Record Mode Setup’ window shown below:

Page 18: TRITON IMAGING, INC. C3D Hardware January 2011. Hardware Configuration Options There are two different configuration options for the C3D: 1. towed 2

Isis Configuration – C3D Data Isis Configuration – C3D Data (page 2)(page 2)

Select the ‘Sonar Setup’ button to open the ‘Select Sonar’ window shown below:

Clicking on the Benthos C3D in the list will open the window shown to the right. This window allows the user to set the hardware configuration parameters

Depending on the type of license you have you may only see one or two sonars in the Select Sonar dialog.

Page 19: TRITON IMAGING, INC. C3D Hardware January 2011. Hardware Configuration Options There are two different configuration options for the C3D: 1. towed 2

Isis Configuration – C3D Data Isis Configuration – C3D Data (page 3)(page 3)

From the Isis main window, select the ‘Record’ button as shown right to launch the Triton C3D server:

Selecting the ‘Settings’ button on the ‘Benthos C3D Controller’ will open a window with four tabs for controlling the C3D sonar (shown on next slide).

1.General2.Connection3.Gains4.Custom

Page 20: TRITON IMAGING, INC. C3D Hardware January 2011. Hardware Configuration Options There are two different configuration options for the C3D: 1. towed 2

Isis Configuration – C3D Data Isis Configuration – C3D Data (page 4)(page 4)

Page 21: TRITON IMAGING, INC. C3D Hardware January 2011. Hardware Configuration Options There are two different configuration options for the C3D: 1. towed 2

Isis Configuration – Motion Isis Configuration – Motion && Epoch Epoch TimeTime

Motion data and epoch time are sent to the acquisition PC by the DSP via a UDP connection. From the ‘Record Mode Setup’ window, select the ‘Ethernet UDP button to launch the following window: Custom Token Descriptions:

G = heading8 = pitch9 = roll{h} = heaveX = ignore value{E} = epoch time

H346.75P-02.719R+001.994^-00.011M600D0A8W0000.00U00.0,1290038508,757577

Page 22: TRITON IMAGING, INC. C3D Hardware January 2011. Hardware Configuration Options There are two different configuration options for the C3D: 1. towed 2

Isis Configuration – Altimeter DataIsis Configuration – Altimeter DataAltimeter data is configured by selecting the ‘Serial Ports’ button from the ‘Record Mode Setup’ window. Selecting this will launch the following window

Use the settings shown in the Serial Port Setup window to the left.

Custom Token Descriptions:

{1.01833} = scalera = altitude

Page 23: TRITON IMAGING, INC. C3D Hardware January 2011. Hardware Configuration Options There are two different configuration options for the C3D: 1. towed 2

Isis Configuration – GPS DataIsis Configuration – GPS DataGPS data is configured by selecting the ‘Serial Ports’ button from the ‘Record Mode Setup’ window. Selecting this will launch the following window

Use the settings shown in the Serial Port Setup window to the left.

Custom Token Descriptions:

NOHDT = ignore heading

NOVTG = ignore vessel speed

Page 24: TRITON IMAGING, INC. C3D Hardware January 2011. Hardware Configuration Options There are two different configuration options for the C3D: 1. towed 2

Isis Configuration – SVS DataIsis Configuration – SVS DataSVS data is routed through the PC to the DSP via ‘udp-serial-gui.exe’. To record the SVS data to the XTF files, Isis needs to be configured to receive the data on the UDP port specified in the C3D Control Panel.

Use the settings shown in the ‘Ethernet UDP Input Setup’ window to the left.

Custom Token Descriptions:

{v} = vessel speed

Select the ‘Ethernet UDP button to launch the following window:

Page 25: TRITON IMAGING, INC. C3D Hardware January 2011. Hardware Configuration Options There are two different configuration options for the C3D: 1. towed 2

C3D System Setup QC C3D System Setup QC (Page 1)(Page 1)Once everything is setup, it is always good practice to verify the data is coming into Isis as expected. Here are a few options:

•Be sure all sensors are connected and powered on

•Be sure the C3D Control Panel is open, the Server.exe and Timeserver.exe programs are running

•Be sure the udp-serial-gui program is running and SVS data are visible

•Open Triton Isis and click on the ‘Record’ button (red circle in the upper left corner of the program) to start the Benthos C3D Controller server application

•In the Benthos C3D Controller “Connected” should be displayed in the upper left, followed by a green circle and a blue flashing circle, and the dialogue area should show MSG_COMMAND Sent: ‘Send Next Ping’ Succeeded, repeating, indicating the C3D is responding to commands from Triton Isis

Page 26: TRITON IMAGING, INC. C3D Hardware January 2011. Hardware Configuration Options There are two different configuration options for the C3D: 1. towed 2

C3D System Setup QC C3D System Setup QC (Page 2)(Page 2)

• The Voltage window should show a transmit peak centered along the x-axis (if both Channels 1 and 2, port/starboard, are enabled, if not, right-click on the display and enable Chan 1), indicating that the C3D transducers are pinging and receiving data

• Perform rub test, by setting range equal to 200m and gains about 20, 0.02, and 20 and rubbing the port transducer followed by the starboard transducer and confirming dark streaks on the Vertical Waterfall, with the port (channel 1) streak below the starboard (channel2) streak, confirming the C3D transducers are connected correctly

• The Vertical Waterfall window should show SV= (some real value, not 1500.0), as supplied from the Odom Digibar SVS, given the value supplied is not below 1350 or above 1650 m/s

• Verify that sensor data is being read properly by Triton Isis, select the Window menu, then Status and Control, and Sensors to open the ‘Sensor Display’ window

Page 27: TRITON IMAGING, INC. C3D Hardware January 2011. Hardware Configuration Options There are two different configuration options for the C3D: 1. towed 2

C3D System Setup QC C3D System Setup QC (Page 3)(Page 3)

• The Isis Parameter Display should show:

a. Lat, Long, Speed, and Heading, according to data received from GPS

b. Gyro, Pitch, and Roll, according to data received from CDL MiniRLG

c. Alt, according to Tritech altimeter (if values are bad, altimeter outputs 50.00m)

• Confirm Date and Time are set to UTC and that the PC time matches that of the GPS, to verify in Triton Isis, select the Window menu, then Status and Control, and Clock Times to display the Current Clock Values window and confirm all times are within 1-2 seconds, as displayed.

Note, the C3D DSP Linux-based CPU will provide the time source for all CDL MiniRLG2 and C3D data, whereas navigation data will be referenced to GPS source or PC, as selected in Triton Isis