triple gem detectors : measurements of stray neutron

21
F.Murtas F.Murtas 1 CNAO- ARDENT Workshop October 19 CNAO- ARDENT Workshop October 19 th th 2012 2012 Triple GEM detectors : Triple GEM detectors : measurements of stray neutron. measurements of stray neutron. GEM as neutron detector Burning Plasma Monitor Neutron detectors Conclusions F.Murtas CERN and LNF-INFN F.Murtas CERN and LNF-INFN E.Aza, R.Froeshl, S.P.George, M.Magistris, S.Puddu, M.Silari E.Aza, R.Froeshl, S.P.George, M.Magistris, S.Puddu, M.Silari

Upload: studs

Post on 19-Jan-2016

51 views

Category:

Documents


0 download

DESCRIPTION

F.Murtas CERN and LNF-INFN. Triple GEM detectors : measurements of stray neutron. GEM as neutron detector Burning Plasma Monitor Neutron detectors Conclusions. E.Aza , R.Froeshl , S.P.George , M.Magistris , S.Puddu , M.Silari. Polietylene Converter Cathode. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Triple GEM detectors : measurements of stray neutron

F.MurtasF.Murtas 11CNAO- ARDENT Workshop October 19CNAO- ARDENT Workshop October 19thth20122012

Triple GEM detectors :Triple GEM detectors :measurements of stray neutron.measurements of stray neutron.

• GEM as neutron detector • Burning Plasma Monitor• Neutron detectors• Conclusions

F.Murtas CERN and LNF-INFN F.Murtas CERN and LNF-INFN

E.Aza, R.Froeshl, S.P.George, M.Magistris, S.Puddu, M.SilariE.Aza, R.Froeshl, S.P.George, M.Magistris, S.Puddu, M.Silari

Page 2: Triple GEM detectors : measurements of stray neutron

F.MurtasF.Murtas 22CNAO- ARDENT Workshop October 19CNAO- ARDENT Workshop October 19thth20122012

Polietylene Converter Cathode Polietylene Converter Cathode 2.5 MeV Neutrons interact with CH2, and, due to elastic scattering processes, protons are emitted and enter in the gas volume generating a detectable signal.

Aluminum thickness ensures the directional capability,

stopping protons that are emitted at a too wide angle.

Optimized CH2–Al thicknesses (50 μm-50 μm) determined by simulations (MCNPX-GEANT4)

Signal No Signal

Page 3: Triple GEM detectors : measurements of stray neutron

F.MurtasF.Murtas 33CNAO- ARDENT Workshop October 19CNAO- ARDENT Workshop October 19thth20122012

Detector Working Point Detector Working Point

ΣΔGEM (V)

Cou

nts

(H

z)

Counting rate Vs chamber gain: up to 890 V the chamber is sensitive to fast neutron but not to gamma rays

Working Point (870 V) NEUTRONS

PHOTONS

Page 4: Triple GEM detectors : measurements of stray neutron

F.MurtasF.Murtas 44CNAO- ARDENT Workshop October 19CNAO- ARDENT Workshop October 19thth20122012

Test at Frascati Neutron Test at Frascati Neutron GeneratorGenerator

ENEA FNGENEA FNG

2.5 MeV2.5 MeV

Measurement of the PH spectrum acquired under 2.5 MeV neutron irradiation at different angles with respect to beam direction and comparison with MCNP. As expected the integrated PH counts decrease when increasing the angle.

Comparison between measurements and simulations suggests that the Al thickness is less than 43 μm. Measured alluminum thikness is 40 μm.

Triple GEM Triple GEM systemsystem

NIO2BEAM NIO2BEAM prototypeprototype

Page 5: Triple GEM detectors : measurements of stray neutron

F.MurtasF.Murtas 55CNAO- ARDENT Workshop October 19CNAO- ARDENT Workshop October 19thth20122012

Fast Neutron Monitor (ISIS)Fast Neutron Monitor (ISIS)Monitor for a fast neutron beam with energies ranging from a few meV to 800 MeV

Tested at neutron beam of the Vesuvio facility at RAL-ISIS.

Beam profiles and intensity Neutron beam monitorig during the shutter opening

NIO2BEAM NIO2BEAM prototypeprototype

Page 6: Triple GEM detectors : measurements of stray neutron

F.MurtasF.Murtas 66CNAO- ARDENT Workshop October 19CNAO- ARDENT Workshop October 19thth20122012

Neutron time lineNeutron time line

Measurement of the difference between the arrival time of bunch and the T0 using GEM counts during a 100 ns wide gate and comparison with proton beam profile intensity

En>2MeV En<2MeV

Page 7: Triple GEM detectors : measurements of stray neutron

F.MurtasF.Murtas 77CNAO- ARDENT Workshop October 19CNAO- ARDENT Workshop October 19thth20122012

1010B Cathode for thermal B Cathode for thermal neutron neutron

Thermal Neutrons interact with 10B, and alfas are emitted entering in the gas volume generating a detectable signal.

Al Support

Gas gap (Ar CO2)10B

Side-On detector

Thermal neutrons

Alfas

cathodeThermal neutrons

Actually 4% efficiency ... working to obtain 50%.

Page 8: Triple GEM detectors : measurements of stray neutron

F.MurtasF.Murtas 88CNAO- ARDENT Workshop October 19CNAO- ARDENT Workshop October 19thth20122012

Monitor for fission reactor Monitor for fission reactor

Measurements at Triga (ENEA)Power of 1 MW

Gamma background freeWithout electronic noise

Only Support

Support with 10BGood linearity up to 1 MW

Online plot

Eff. = 4%

Page 9: Triple GEM detectors : measurements of stray neutron

F.MurtasF.Murtas 99CNAO- ARDENT Workshop October 19CNAO- ARDENT Workshop October 19thth20122012

N-TOF Thermal neutron Beam N-TOF Thermal neutron Beam spotspot

Time spectrum (1ms/bin)

150ms gate

Single event

online measurement

Page 10: Triple GEM detectors : measurements of stray neutron

F.MurtasF.Murtas 1010CNAO- ARDENT Workshop October 19CNAO- ARDENT Workshop October 19thth20122012

Imaging of Thermal Neutron beamImaging of Thermal Neutron beamthrough a cadmium grid (ISIS)through a cadmium grid (ISIS)

Beam

Online plot

Page 11: Triple GEM detectors : measurements of stray neutron

F.MurtasF.Murtas 1111CNAO- ARDENT Workshop October 19CNAO- ARDENT Workshop October 19thth20122012

X-Ray Monitor for X-Ray Monitor for radioactive wasteradioactive waste

Gamma Monitor for Gamma Monitor for

radiotherapyradiotherapy

Page 12: Triple GEM detectors : measurements of stray neutron

F.MurtasF.Murtas 1212CNAO- ARDENT Workshop October 19CNAO- ARDENT Workshop October 19thth20122012

X-Ray ImagesX-Ray Images

X-Ray 6 KeVWith a mesh of 600 micron holes Pitch of 2 mm

X-Ray beam of 6 KeV

This detector will be used for imaging of radioactive waste at CERN

Page 13: Triple GEM detectors : measurements of stray neutron

F.MurtasF.Murtas 1313CNAO- ARDENT Workshop October 19CNAO- ARDENT Workshop October 19thth20122012

Continous

x-rays ~60 keV

Pulsed (5 s)

gamma radiation

<50 MeV

GEM on medical imagingGEM on medical imaging

Page 14: Triple GEM detectors : measurements of stray neutron

F.MurtasF.Murtas 1414CNAO- ARDENT Workshop October 19CNAO- ARDENT Workshop October 19thth20122012

Gamma flux measurements at Gamma flux measurements at PTVPTV

Gamma flux of 108 Hrz/cm2 6-1 MeV

Gamma radiotherapyPoliclinico Tor Vergata

Pixel0.5 x 0.5 mm2

Page 15: Triple GEM detectors : measurements of stray neutron

F.MurtasF.Murtas 1515CNAO- ARDENT Workshop October 19CNAO- ARDENT Workshop October 19thth20122012

SummarySummary

Tests at Policlinico Tor Vergata (Rome) for Gamma Monitor show good and promising results

Two GEM neutron monitor has been tested, at ISIS neutron spallation source, nuclear reactor Triga, nTOF at CERN. A fast neutron detector with polietylene

Developments are in progress improving directionality and spectroscopy

A thermal neutron detector with Boron cathode with 4% efficiency

Developments are in progress improving efficiency (40-50%)

Page 16: Triple GEM detectors : measurements of stray neutron

F.MurtasF.Murtas 1616CNAO- ARDENT Workshop October 19CNAO- ARDENT Workshop October 19thth20122012

GEM Performances (2002-GEM Performances (2002-2006) 2006)

The results of several tests* on 10x10 cm2 prototype allowed us to select the Ar/CO2/CF4 with geometry 3/1/2/1 mm

better time resolution 4.8 ns in respect of Ar/CO2

G.Bencivenni et al., NIM A 518 (2004) 106

Ageing studies on whole detector area 20x24 cm2: 25 kCi 60Co source at 10 MHz/cm2 on 500 cm2

Integrated charge 2.2 C/cm2

P. de Simone et al., IEEE Trans. Nucl. Sci. 52 (2005) 2872

Detector performance recovered with a 15 V shift on HV

higher efficiency at lower gas gain : 96% in 20 ns

Max space resolution O(100 m)

Page 17: Triple GEM detectors : measurements of stray neutron

F.MurtasF.Murtas 1717CNAO- ARDENT Workshop October 19CNAO- ARDENT Workshop October 19thth20122012

The rate capability was measured with an X-ray (5.9 keV) tube over a spot of ~ 1 mm2

The detector was operated at a gain of ~ 2x104

A very good gain stability was found up to a photon counting rate of 50 MHz/cm2

LHCb M1R1 maximum rate (460 kHz /cm2)

Rate (Hz/cm2)

Linearity at very high rate Linearity at very high rate

Page 18: Triple GEM detectors : measurements of stray neutron

F.MurtasF.Murtas 1818CNAO- ARDENT Workshop October 19CNAO- ARDENT Workshop October 19thth20122012

The effective GAIN Geff of the detector has been measured using a 5.9 keV X-ray tube, measuring the rate R and the current i, induced on pads, by X-rays incident on the GEM detector.

Geff = A eα(Vgem1+Vgem2+Vgem3)

A and α depend on the gas mixture.

Geff = i / eNR

Gas GainGas Gain

Page 19: Triple GEM detectors : measurements of stray neutron

F.MurtasF.Murtas 1919CNAO- ARDENT Workshop October 19CNAO- ARDENT Workshop October 19thth20122012

At PSI we exposed three detectors to a particle flux up to 300 MHz.

Each detector integrated, without any damage, about 5000 discharges.

In order to have no more than 5000 discharges in 10 years in M1R1 the discharge probability has to be kept below 2.5 10-12 (G < 17000).

This limit is conservative because up to 5000 discharges no damage was observed.

G~4000 G~17000

Working region

Discharge probabilityDischarge probability

Page 20: Triple GEM detectors : measurements of stray neutron

F.MurtasF.Murtas 2020CNAO- ARDENT Workshop October 19CNAO- ARDENT Workshop October 19thth20122012

Carioca Card Sensitivity Carioca Card Sensitivity

The sensitivity is measured vs two different thresholds

DAC Threshold on power supply Threshold on Carioca

6mV/fC

Page 21: Triple GEM detectors : measurements of stray neutron

F.MurtasF.Murtas 2121CNAO- ARDENT Workshop October 19CNAO- ARDENT Workshop October 19thth20122012

Carioca Card Sensitivity Carioca Card Sensitivity

The sensitivity has been measured injecting a charge between 5 and 20 fC with different width

Q = 5 fCwidth=10 ns

LVDS 5 ns

Q = 5 fCwidth=20 ns

Q = 5 fCwidth=30 ns

LVDS 15 ns

LVDS 17 ns