tray cables for industrial plant installations the right ... · tr 600 hd is a severe duty motor...

24
SPECIAL CABLES | CONTROL CABLES CONTINUOUS FLEX CABLES | CABLE HARNESSING TEMPERATURE MEASUREMENT 866-722-2974 • www.sabcable.com TRAY CABLES FOR INDUSTRIAL APPLICATIONS

Upload: others

Post on 22-Jun-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: TRAY CABLES FOR INDUSTRIAL PLANT INSTALLATIONS THE RIGHT ... · TR 600 HD is a severe duty motor supply cable for use in applications that require tray cable ratings, flexibility,

SPECIAL CABLES | CONTROL CABLES CONTINUOUS FLEX CABLES | CABLE HARNESSING

TEMPERATURE MEASUREMENT

866-722-2974 • www.sabcable.com

TRAY CABLES FOR INDUSTRIAL APPLICATIONS

Page 2: TRAY CABLES FOR INDUSTRIAL PLANT INSTALLATIONS THE RIGHT ... · TR 600 HD is a severe duty motor supply cable for use in applications that require tray cable ratings, flexibility,

2

S NORTH AMERICA ABOUT US

S North America is a focused supplier for the automation, aerospace, medical, high temperature, and robotics industries, providing cable solutions that meet, exceed, and set new standards in the flexible cable market. In addition to flexible cable products, we offer an extensive inventory of high-quality cable accessories including cord grips, grounding glands and other accessories that complement our flexible control and automation cables. Whatever the need may be, look to S North America for Special Cables that can, for example, help minimize maintenance costs and increase productivity, reduce downtime, and solve specific problems. Here is a small sample of some of the challenges that Special Cables from SAB North America can help address:

• Hybrid designs for multiple functions • Harsh environments • Difficult applications • Industry-specific requirements.

S North America offers a well-stocked line of UL and CSA-listed tray cables for use in control systems, machinery, conveyors, control panels, assembly and production lines and processing equipment. Each carries a Class 1 Division 2 explosion classification and a WTTC rating for wind turbines. The lineup features flexible versions as well as round cables that allow installers to pull more cables at a time, thereby avoiding a stiff, complicated setup.

S’s level of speed and service as a supplier is unmatched. S lives up to its name in not only flexible cable but also flexible manufacturing. Special cables can be designed, manufactured and delivered in just 6-8 weeks, and even faster in special circumstances!

SAB Service Advantage...We make it Easy• Cut to length with no cut charges • Prepaid freight within US for orders over $2,500 • Specialty cable designs (1500 ft minimum) • No minimum on orders

• Free drop shipments (no surcharges) • 24-hour shipments from stock • Cord Grips for securing cables

866-722-2974 • www.sabcable.com

Page 3: TRAY CABLES FOR INDUSTRIAL PLANT INSTALLATIONS THE RIGHT ... · TR 600 HD is a severe duty motor supply cable for use in applications that require tray cable ratings, flexibility,

3

T TRAY CABLE TABLE OF CONTENTS

Semi-Rigid Data Cables

n DC 105 300V UL PLTC, ITC, CMG & CSA CMG multi-conductor data cable unshielded, PVC 5

n DC 105 C 300V UL PLTC, ITC, CMG & CSA CMG multi-conductor data cable shielded, PVC 6

n DC 105 C TP 300V UL PLTC, ITC, CMG & CSA CMG multi-pair data cable shielded, PVC 7

UV and Oil Resistant, Flexible Tray Cables

n TR 600 S 600V UL TC-ER, MTW & CSA CIC/TC multi-conductor tray cable unshielded, PVC 8

n TR 600 S CY 600V UL TC-ER, MTW & CSA CIC/TC multi-conductor tray cable shielded, PVC 9

n TR 600 S Gray 600V UL TC-ER, MTW & CSA CIC/TC multi-conductor tray cable unshielded, PVC 10

n TR 600 S CY Gray 600V UL TC-ER, MTW & CSA CIC/TC multi-conductor tray cable shielded, PVC 11

n TR 600 Plus 600V UL TC-ER, MTW & c(UL) CIC/TC multi-conductor reduced diameter tray cable unshielded, PVC 12

n TR 600 CY Plus 600V UL TC-ER, MTW & c(UL) CIC/TC multi-conductor reduced diameter tray cable shielded, PVC 13

n TR 850 S 600V UL TC-ER/STOOW & CSA STOOW/c(UL) CIC/TC multi-conductor tray cable and flexible cordage, PVC 14

Heavy Duty Tray Cablesn TR HD TPE 600V UL TC-ER & c(UL) CIC/TC multi-conductor unshielded tray cable with

blue conductors, TPE 15

n TR 600 HD 600V UL TC-ER & c(UL) CIC/TC multi-conductor tray cable unshielded, TPE 16

n TR 600 C HD 600V UL TC-ER & c(UL) CIC/TC multi-conductor tray cable shielded, TPE 17

Heavy Duty Continuous Flex Tray Cables

n TR 600 Auto HD 600V UL TC-ER, MTW & c(UL) CIC/TC multi-conductor tray cable unshielded, TPE 18

n TR 600 Auto C HD 600V UL TC-ER, MTW & c(UL) CIC/TC multi-conductor tray cable shielded, TPE 19

Cable Design Capabilities 20

Secure & Ground Your Cable with Cord Grips 22

Additional Products 23

866-722-2974 • www.sabcable.com

Page 4: TRAY CABLES FOR INDUSTRIAL PLANT INSTALLATIONS THE RIGHT ... · TR 600 HD is a severe duty motor supply cable for use in applications that require tray cable ratings, flexibility,

4

T TRAY CABLE SELECTION CHART

*The temperature range for flexing is mentioned on the product specification page.1 18-16 AWG only

866-722-2974 • www.sabcable.com

DC

105

DC

105

C

DC

105

C T

P

TR 6

00 S

TR 6

00 S

CY

TR 6

00 P

lus

TR 6

00 C

Y Pl

us

TR 8

50 S

Tray

HD

TPE

TR 6

00 H

D

TR 6

00 C

HD

TR 6

00 A

uto

HD

TR 6

00 A

uto

C H

D

Con

duct

ors Numbered conductors x x x x x x x x x

Color code chart 2, 4 and 6 x x

Color code chart 3 x

Colored x

Insu

latio

n Semi-rigid PVC (26 -20 AWG) x x x

PVC x

PVC/nylon x x x x x x x x x x x x

Shie

ldin

g Tinned Copper Braid x x x

Foil & Tinned Copper Braid x x x

Inner jacket x

Jack

et

Gray Jacket PVC PVC PVC PVC PVC TPE

Black Jacket PVC PVC PVC PVC TPE TPE TPE

Orange Jacket TPE TPE

Tem

pera

ture

Ra

nge

Stat

ic*

+ 105°C

+ 90°C

– 25°C– 40°C

olta

ge

300 V x x x

600 V x x x x x x x x x x

1000 V CSA AWM x x x

1000 V (UL) WTTC x x x x x x x x x x

Testing voltage 2000 V x x x x x x x x x x x x x

Cha

ract

eris

tics

Burning characteristics: FT1, FT4 x x x x x x x x x x

Cold bend test -25°C x x x

Cold bend test -40°C x x x x x x x x x x

Oil resistance I x x

Oil resistance I + II x x x x x x x x

Sunlight resistance x x x x x x x x x

Exposed runs x1 x1 x1 x x x x x x x x x x

Direct burial x x x x x x x x x x

Machinery area x x x x x x x x x x x x x

Continuous Flex x x

Page 5: TRAY CABLES FOR INDUSTRIAL PLANT INSTALLATIONS THE RIGHT ... · TR 600 HD is a severe duty motor supply cable for use in applications that require tray cable ratings, flexibility,

5

S TRAY CABLES DC 105 Type PLTC, ITC, CMG, & CSA Approved Semi-rigid PVC data cable

Marking for DC 105 DC3332203: S North America P/N DC3332203 22AWG/3c (UL) TYPE PLTC or ITC or CMG 105°C (DC 105) - CSA TYPE CMG or AWM I/II A/B 105°C 300V FT4 RoHS C

DC 105 is an unshielded, multi-conductor signal and control cable recommended for use with computers, data transmission, office equipment, process control equipment and instrumentation. DC 105 has finer stranding for improved flexibility and is oil resistant.

® 26 AWG (7/34) DC3222603 3 4.0 DC3222604 4 4.2 DC3222606 6 4.8 DC3222607 7 4.9 DC3222608 8 5.2 DC3222610 10 5.8 DC3222615 15 6.6 DC3222620 20 7.5 DC3222625 25 8.2 ® 24 AWG (7/32) DC3222402 2 4.1 DC3222403 3 4.2 DC3222404 4 4.6 DC3222405 5 4.9 DC3222406 6 5.2 DC3222407 7 5.3 DC3222408 8 5.6 DC3222410 10 6.3 DC3222412 12 6.5 DC3222415 15 7.2 DC3222418 18 7.7 DC3222420 20 7.9 DC3222425 25 8.7 ® 22 AWG (7/30) DC3332202 2 4.5 DC3332203 3 4.8 DC3332204 4 5.1 DC3332205 5 5.4 DC3332206 6 5.8 DC3332207 7 5.9 DC3332208 8 6.2 DC3332209 9 6.6 DC3332210 10 7.3 DC3332212 12 7.5 DC3332215 15 8.1 DC3332218 18 8.6 DC3332220 20 8.8 DC3332225 25 9.8 DC3332230 30 10.9 DC3332240 40 12.1 DC3332250 50 13.1

item no. no. of conductors

nominal outer-ø inch mm

cable weight

≈ lbs/mft

item no. no. of conductors

nominal outer-ø inch mm

cable weight

≈ lbs/mft

® 20 AWG (19/32) DC3332002 2 5.0 DC3332003 3 5.2 DC3332004 4 5.6 DC3332006 6 6.5 DC3332007 7 6.5 DC3332008 8 7.0 DC3332009 9 7.7 DC3332010 10 8.3 DC3332012 12 8.5 DC3332015 15 9.1 DC3332020 20 10.5 DC3332025 25 11.7 ® 18 AWG (19/30) DC3331802 2 7.0 DC3331803 3 7.4 DC3331804 4 8.0 DC3331805 5 8.6 DC3331806 6 9.3 DC3331807 7 9.3 DC3331808 8 10.0 DC3331809 9 10.7 DC3331810 10 11.6 DC3331812 12 12.0 DC3331815 15 12.9 DC3331818 18 14.7 DC3331820 20 15.1 DC3331825 25 16.8 DC3331850 50 23.0 ® 16 AWG (26/30) DC3331602 2 7.5 DC3331603 3 7.9 DC3331604 4 8.6 DC3331605 5 9.3 DC3331606 6 10.1 DC3331607 7 10.1 DC3331608 8 10.9 DC3331609 9 11.7 DC3331610 10 12.6 DC3331612 12 13.0 DC3331615 15 14.8 DC3331618 18 16.0 DC3331620 20 16.4 DC3331625 25 18.3

0.156 0.166 0.189 0.192 0.204 0.230 0.261 0.295 0.324 0.160 0.167 0.182 0.191 0.204 0.207 0.220 0.249 0.256 0.283 0.303 0.311 0.344 0.178 0.190 0.202 0.213 0.228 0.231 0.245 0.261 0.289 0.297 0.317 0.339 0.348 0.385 0.430 0.475 0.517

18 20 25 26 28 36 48 58 70

20 23 24 27 30 31 35 43 49 59 65 70 86

22 25 29 34 40 41 46 53 60 67 79 87 94

117 143 184 221

14 green/white 15 blue/white 16 black/red 17 white/red 18 orange/red 19 blue/red 20 red/green 21 orange/green 22 black/white/red 23 white/black/red 24 red/black/white 25 green/black/white

Conductor no. Color

Color Code chart 2

1 black 2 white 3 red 4 green 5 orange 6 blue 7 white/black 8 red/black 9 green/black 10 orange/black 11 blue/black 12 black/white 13 red/white

Conductor no. Color

14 white/orange 15 white/yellow 16 white/green 17 white/blue 18 white/violet 19 white/gray 20 white/black/brown 21 white/black/red 22 white/black/orange 23 white/black/yellow 24 white/black/green 25 white/black/blue

Conductor no. Color

Color Code chart 4

1 black 2 brown 3 red 4 orange 5 yellow 6 green 7 blue 8 violet 9 gray 10 white 11 white/black 12 white/brown 13 white/red

Conductor no. Color

14 red/yellow 15 red/black 16 white/black 17 white/red 18 white/green 19 white/yellow 20 white/blue 21 white/brown 22 white/orange 23 white/gray 24 white/violet 25 white/black/red

Conductor no. Color

Color Code chart 6

1 black 2 red 3 white 4 green 5 orange 6 blue 7 brown 8 yellow 9 violet 10 gray 11 pink 12 tan 13 red/green

Conductor no. Color

0.196 0.205 0.220 0.254 0.254 0.275 0.303 0.325 0.335 0.358 0.415 0.459 0.276 0.290 0.313 0.339 0.366 0.367 0.395 0.423 0.457 0.472 0.507 0.579 0.595 0.662 0.904 0.296 0.312 0.337 0.366 0.396 0.397 0.428 0.459 0.497 0.513 0.584 0.629 0.647 0.721

29 35 42 55 52 62 74 80 92

110 143 184

45 58 70 78 91 98

110 124 144 164 194 244 263 325 621

54 68 83 95

109 119 134 160 174 199 261 297 330 400

Construction: Conductor: tinned copper strands Insulation: 26 - 20 AWG semi-rigid PVC 18 - 16 AWG PVC/Nylon Color code: 26 - 24 AWG color code chart 2 22 AWG color code chart 4 20 - 16 AWG color code chart 6 Stranding: twisted together in layers with non-wicking fillers Jacket material: PVC Jacket color: gray

Technical data: Nominal voltage: 300 V Testing voltage: 2000 V Min. bending radius fixed installation: 4 x O.D. Temperature: -25/+105°C Approvals: UL: CMG (UL PLTC & ITC 22 - 20 AWG) (UL PLTC-ER & ITC-ER 18- 16 AWG) CSA: CMG/FT4 AWM I/II A/B Absence of acc. to RoHS directive of the European Union harmful substances: see page O/30 in full line catalog

105°C (DC 105) - CSA TYPE CMG or AWM I/II A/B 105°C 300V FT4 RoHS C

33C

866-722-2974 • www.sabcable.com

Page 6: TRAY CABLES FOR INDUSTRIAL PLANT INSTALLATIONS THE RIGHT ... · TR 600 HD is a severe duty motor supply cable for use in applications that require tray cable ratings, flexibility,

Marking for DC 105 C DC3332204S: S North America P/N DC3332204S 22AWG/4c (UL) TYPE PLTC OR ITC OR CMG SHIELDED 105°C (DC 105 C) CSA TYPE CMG OR AWM I/II A/B 105°C 300V FT4 RoHS C

CMG OR AWM I/II A/B 105°C 300V FT4 RoHS C

DC 105 C is a shielded, multi-conductor signal and control cable recommended for data transmission, process control, and all other signal and data communications. It has an overall foil tape with drain wire and tinned copper braid that is recommended whenever electrical interference distorts signal transmissions, or when EMI emissions need to be supressed. DC 105 C has finer stranding for improved flexibility and is oil resistant.

Construction: Conductor: tinned copper strands Insulation: 26 - 20 AWG semi-rigid PVC 18 - 16 AWG PVC/Nylon Color code: 26 - 24 AWG color code chart 2 22 AWG color code chart 4 20 - 16 AWG color code chart 6 Stranding: twisted together in layers with non-wicking fillers Screen: double screen, alu-foil, tinned copper braiding and tinned drain wire Jacket material: PVC Jacket color: gray

Technical data: Nominal voltage: 300 V Testing voltage: 2000 V Min. bending radius fixed installation: 6 x O.D. Temperature: -25/+105°C Approvals: UL: CMG (UL PLTC & ITC 22 - 20 AWG) (UL PLTC-ER & ITC-ER 18- 16 AWG) CSA: CMG/FT4 AWM I/II A/B Absence of acc. to RoHS directive of the European Union harmful substances: see page O/30 in full line catalog

® 26 AWG (7/34) DC3222602S 2 4.6 DC3222603S 3 4.7 DC3222604S 4 5.0 DC3222605S 5 5.3 DC3222606S 6 5.6 DC3222607S 7 5.6 DC3222608S 8 5.9 DC3222610S 10 6.6 DC3222615S 15 7.3 DC3222618S 18 7.8 DC3222625S 25 8.7 ® 24 AWG (7/32) DC3222403S 3 5.0 DC3222404S 4 5.3 DC3222405S 5 5.6 DC3222406S 6 5.9 DC3222407S 7 6.0 DC3222408S 8 6.3 DC3222409S 9 6.6 DC3222410S 10 7.3 DC3222412S 12 7.3 DC3222415S 15 7.9 DC3222418S 18 8.4 DC3222420S 20 8.6 DC3222425S 25 9.4

item no. no. of conductors

nominal outer-ø inch mm

cable weight

≈ lbs/mft

item no. no. of conductors

nominal outer-ø inch mm

cable weight

≈ lbs/mft

® 22 AWG (7/30) DC3332203S 3 5.3 DC3332204S 4 5.7 DC3332205S 5 6.0 DC3332206S 6 6.4 DC3332207S 7 6.6 DC3332208S 8 6.8 DC3332210S 10 7.9 DC3332212S 12 8.1 DC3332215S 15 8.6 DC3332218S 18 9.2 DC3332220S 20 9.4 DC3332225S 25 11.0 ® 20 AWG (19/32) DC3332003S 3 5.8 DC3332004S 4 6.2 DC3332006S 6 7.3 DC3332008S 8 7.8 DC3332010S 10 8.8 DC3332015S 15 9.7 DC3332020S 20 11.1 DC3332025S 25 12.2 ® 18 AWG (19/30) DC3331803S 3 8.0 DC3331804S 4 8.6 DC3331806S 6 9.9 ® 16 AWG (26/30) DC3331603S 3 8.5 DC3331604S 4 9.2 DC3331606S 6 10.7

0.180 0.186 0.196 0.207 0.219 0.221 0.231 0.258 0.289 0.307 0.343 0.197 0.209 0.221 0.234 0.236 0.248 0.261 0.288 0.288 0.312 0.332 0.340 0.372

27 30 32 34 37 39 43 51 66 70 88

35 36 39 45 46 51 56 62 67 80 86 92

111

14 green/white 15 blue/white 16 black/red 17 white/red 18 orange/red 19 blue/red 20 red/green 21 orange/green 22 black/white/red 23 white/black/red 24 red/black/white 25 green/black/white

Conductor no. Color

Color Code chart 2

1 black 2 white 3 red 4 green 5 orange 6 blue 7 white/black 8 red/black 9 green/black 10 orange/black 11 blue/black 12 black/white 13 red/white

Conductor no. Color

14 white/orange 15 white/yellow 16 white/green 17 white/blue 18 white/violet 19 white/gray 20 white/black/brown 21 white/black/red 22 white/black/orange 23 white/black/yellow 24 white/black/green 25 white/black/blue

Conductor no. Color

Color Code chart 4

1 black 2 brown 3 red 4 orange 5 yellow 6 green 7 blue 8 violet 9 gray 10 white 11 white/black 12 white/brown 13 white/red

Conductor no. Color

14 red/yellow 15 red/black 16 white/black 17 white/red 18 white/green 19 white/yellow 20 white/blue 21 white/brown 22 white/orange 23 white/gray 24 white/violet 25 white/black/red

Conductor no. Color

Color Code chart 6

1 black 2 red 3 white 4 green 5 orange 6 blue 7 brown 8 yellow 9 violet 10 gray 11 pink 12 tan 13 red/green

Conductor no. Color

0.210 0.224 0.237 0.252 0.260 0.267 0.312 0.320 0.339 0.362 0.371 0.433 0.229 0.244 0.289 0.307 0.348 0.380 0.437 0.481 0.314 0.337 0.390 0.336 0.361 0.420

40 43 49 54 57 61 77 86 99

110 118 150

51 59 73 85

102 135 169 213

79 92

116

93 111 139

33C

6

S TRAY CABLES DC 105 C Type PLTC, ITC, CMG, & CSA Approved Shielded semi-rigid PVC data cable

866-722-2974 • www.sabcable.com

Page 7: TRAY CABLES FOR INDUSTRIAL PLANT INSTALLATIONS THE RIGHT ... · TR 600 HD is a severe duty motor supply cable for use in applications that require tray cable ratings, flexibility,

7

S TRAY CABLES DC 105 C TP Type PLTC, ITC, CMG, & CSA Approved Shielded semi-rigid twisted pair PVC data cable

® 24 AWG (7/32) DC3222401TP* 1 4.8 DC3222402TP 2 6.2 DC3222403TP 3 6.6 DC3222404TP 4 7.4 DC3222405TP 5 7.8 DC3222406TP 6 8.3 DC3222408TP 8 8.9 DC3222409TP 9 9.5 DC3222415TP 15 11.7 ® 22 AWG (7/30) DC3332201TP* 1 5.2 DC3332202TP 2 6.8 DC3332203TP 3 7.3 DC3332204TP 4 8.2 DC3332205TP 5 8.5 DC3332206TP 6 9.1 DC3332208TP 8 9.7 DC3332209TP 9 10.9 DC3332211TP 11 11.7 DC3332215TP 15 12.8 *DC3222401TP & DC3332201TP: *black paired with white color code

item no. no. of pairs

nominal outer-ø inch mm

cable weight

≈ lbs/mft

item no. no. of pairs

nominal outer-ø inch mm

cable weight

≈ lbs/mft

® 20 AWG (19/32) DC3332001TP 1 5.6 DC3332002TP 2 7.7 DC3332003TP 3 8.2 DC3332004TP 4 8.8 DC3332006TP 6 10.7 DC3332009TP 9 12.2 DC3332015TP 15 14.5 ® 18 AWG (19/30) DC3331801TP 1 7.6 DC3331802TP 2 10.5 DC3331803TP 3 11.2 DC3331804TP 4 12.1 DC3331806TP 6 15.1 DC3331809TP 9 17.4 DC3331815TP 15 20.9 ® 16 AWG (26/30) DC3331601TP 1 8.1 DC3331602TP 2 11.4 DC3331603TP 3 12.0 DC3331604TP 4 13.1

0.190 0.246 0.258 0.292 0.307 0.328 0.351 0.373 0.460 0.203 0.266 0.289 0.323 0.333 0.358 0.383 0.429 0.460 0.505

31 44 51 57 65 73 85 97

151

32 50 63 71 80 90

107 128 154 188

Color Code chart 3

1 black paired with red 2 black paired with white 3 black paired with green 4 black paired with blue 5 black paired with yellow 6 black paired with brown 7 black paired with orange 8 red paired with white 9 red paired with green 10 red paired with blue 11 red paired with yellow 12 red paired with brown 13 red paired with orange 14 green paired with white 15 green paired with blue 16 green paired with yellow 17 green paired with brown 18 green paired with orange 19 white paired with blue 20 white paired with yellow 21 white paired with brown 22 white paired with orange 23 blue paired with yellow 24 blue paired with brown 25 blue paired with orange

Pair no. Color combination

0.220 0.305 0.321 0.345 0.422 0.482 0.572 0.300 0.415 0.439 0.476 0.595 0.686 0.823 0.320 0.448 0.474 0.515

42 67 80 95

129 180 254

68

106 128 162 231 312 461

78

124 162 192

Marking for DC 105 C TP DC3332203TP: S North America P/N DC3332203TP 22AWG/3pr (UL) TYPE PLTC or ITC or CMG SHIELDED 105°C (DC 105 CTP) CSA TYPE CMG or AWM I/II A/B 105°C 300V FT4 RoHS C

AWM I/II A/B 105°C 300V FT4 RoHS C

DC 105 C TP is a shielded, multi-pair signal and control cable designed for use with process control instrumentation, computers, data transmission, and office equipment. It has an overall foil tape with drain wire and tinned copper braid that is recommended whenever electrical interference distorts signal transmissions, or when EMI emissions need to be supressed. DC 105 C TP has finer stranding for improved flexibility and is oil resistant.

Construction: Conductor: tinned copper strands Insulation: 24 - 20 AWG semi-rigid PVC 18 - 16 AWG PVC/Nylon Color code: color code chart 3 Stranding: paired and twisted together in layers with non-wicking fillers Screen: double screen, alu-foil, tinned copper braiding and tinned drain wire Jacket material: PVC Jacket color: gray

Technical data: Nominal voltage: 300 V Testing voltage: 2000 V Min. bending radius fixed installation: 6 x O.D. Temperature: -25/+105°C Approvals: UL: CMG (UL PLTC & ITC 22 - 20 AWG) (UL PLTC-ER & ITC-ER 18- 16 AWG) CSA: CMG/FT4 AWM I/II A/B Absence of acc. to RoHS directive of the European Union harmful substances: see page O/30 in full line catalog

33C

866-722-2974 • www.sabcable.com

Page 8: TRAY CABLES FOR INDUSTRIAL PLANT INSTALLATIONS THE RIGHT ... · TR 600 HD is a severe duty motor supply cable for use in applications that require tray cable ratings, flexibility,

Marking for TR 600 S 93331641: SAB NORTH AMERICA TR 600 S 93331641 16 AWG/41C (UL) TC-ER 90C DRY 75C WET 600V SUN RES DIR BUR OIL RES I/II OR WTTC 1000V OR MTW "FLEXING" OR DP-1 OR AWM 2586 105°C CSA CIC-TC PVC/N 90°C DRY 75°C WET 600V -25°C SR FT4 OR AWM I/II A/B 90C 1000V FT4 RoHS C

-25°C SR FT4 OR AWM I/II A/B 90C 1000V FT4 RoHS C

TR 600 S is a multi-conductor, UL & CSA approved flexible tray cable. It is rated UL TC-ER, MTW, AWM and CSA CIC/TC for 600 V, 90°C and UL WTTC and CSA AWM 1000V. TR 600 S black is UV, oil resistant (Oil Res I & II) and is submersible pump rated (3-7 cond.). This cable can be used without conduit (exposed runs). The reduced outer diameter permits easy handling and installation in confined areas. TR 600 S tray cable is designed for use in all electrical equipment in dry, damp and wet conditions. Recommended applications are machine tools, control systems, assembly lines, CNC machining centers, grinding machines, bottling equipment, data processing equipment and connections between control panels and machines. TR 600 S is permitted to be used in hazardous (classified) locations Class I, Division 2 per NEC Article 501.4 (B) and is UL Type TC in acc. to UL standard 1277 and NEC Article 336 (392, 501). Additional uses include wind turbine power and control cable intended to be installed in cable trays or raceways within a wind turbine generator and NFPA 79 Machine areas.

® 18 AWG 93331802* 2 7.3 93331803 3 7.6 93331804 4 8.2 93331805 5 8.9 93331807 7 9.6 93331809 9 11.0 93331812 12 12.2 93331818 18 15.1 93331825 25 17.4 93331850 50 23.9 ® 16 AWG 93331602* 2 7.8 93331603 3 8.2 93331604 4 8.8 93331605 5 9.6 93331607 7 10.5 93331608 8 11.2 93331609 9 12.0 93331612 12 13.4 93331616 16 15.6 93331618 18 16.4

item no. no. of conductors incl. ground

nominal outer-ø inch mm

cable weight

≈ lbs/mft

item no. no. of conductors incl. ground

nominal outer-ø inch mm

cable weight

≈ lbs/mft

item no. no. of conductors incl. ground

nominal outer-ø inch mm

cable weight

≈ lbs/mft

® 16 AWG 93331619 19 16.4 93331625 25 18.9 93331634 34 22.5 93331637 37 22.8 93331641 41 24.0 93331650 50 26.0 ® 14 AWG 93331402* 2 8.8 93331403 3 9.2 93331404 4 10.1 93331405 5 10.9 93331407 7 12.0 93331409 9 14.7 93331412 12 16.4 93331418 18 18.9 93331425 25 23.0 ® 12 AWG 93331202* 2 9.8 93331203 3 10.2 93331204 4 11.2 93331205 5 12.2 93331207 7 13.4

® 10 AWG 93331003 3 12.4 93331004 4 14.4 93331005 5 15.7 93331007 7 17.1 ® 8 AWG 93330803 3 16.8 93330804 4 18.5 93330805 5 21.0 ® 6 AWG 93330603 3 19.4 93330604 4 22.3 93330605 5 24.2 ® 4 AWG 93330403 3 24.5 93330404 4 26.9 93330405 5 29.9 ® 2 AWG 93330203 3 28.3 93330204 4 29.5 93330205 5 34.6

Other dimensions and colors are possible on request. *2 conductor cables are rated UL TC only

0.286 0.300 0.324 0.349 0.376 0.432 0.480 0.596 0.686 0.940 0.306 0.321 0.348 0.376 0.412 0.440 0.473 0.527 0.613 0.646

45 55 67 79

100 125 157 244 319 622

52 70 81 96

126 137 152 196 273 300

0.646 0.746 0.884 0.896 0.945 1.025 0.346 0.364 0.396 0.430 0.472 0.578 0.644 0.744 0.904 0.385 0.403 0.440 0.479 0.526

310 395 544 592 654 756

65 88

112 130 169 236 297 417 596

99

120 150 189 240

0.487 0.568 0.618 0.674 0.662 0.728 0.826 0.765 0.879 0.954 0.966 1.061 1.179 1.114 1.160 1.363

179 248 298 403

309 388 465

443 580 717

696 845

1035

977 1215 1575

Construction: Conductor: bare copper strands class K (30 AWG multiple strands) Insulation: special formulated PVC/Nylon Color code: black conductors with consecutive white numbers; green-yellow earth wire from 3 conductors Stranding: in layers Jacket material: special oil resistant pressure extruded PVC Jacket color: black

Outstanding features: ä flexible stranding for easy installation ä oil resistant meeting UL Oil Res I and II ä NFPA 79 for Industrial Machinery ä UL TC-ER (exposed runs) ä CSA approved for TC ä Submersible pump (14 AWG ≥, 3 thru 7 cond.) ä WTTC: Wind turbine tray cable

Technical data: Voltage: UL-AWM / (UL) / CSA: 600 V (UL) WTTC: 1000 V Testing voltage: 2000 V Min. bending radius fixed installation: 4 x O.D. free movement: 6 x O.D. Temperature: UL-AWM: (UL) / CSA: up to +105°C up to +90°C static: -40°C Burning characteristics: (UL) FT4 and CSA FT1, FT2, FT4 Oil resistance I + II: yes Sunlight resistance: yes Exposed Runs: yes Cold bend test: -40°C Direct Burial: yes Machinery Area: yes Absence of acc. to RoHS directive of the European Union harmful substances: see page O/30 in full line catalog

33C

8

S TRAY CABLES TR 600 S Type TC-ER, MTW, WTTC, & CSA Approved UV and Oil resistant 90°C flexible tray cable

866-722-2974 • www.sabcable.com

Page 9: TRAY CABLES FOR INDUSTRIAL PLANT INSTALLATIONS THE RIGHT ... · TR 600 HD is a severe duty motor supply cable for use in applications that require tray cable ratings, flexibility,

9

S TRAY CABLES TR 600 S CY Type TC-ER, MTW, WTTC, & CSA Approved UV and oil resistant 90°C shielded flexible tray cable

® 18 AWG 93341803 3 8.2 93341804 4 8.8 93341805 5 9.5 93341807 7 10.2 93341809 9 11.6 93341812 12 12.8 93341818 18 15.7 93341825 25 18.0 ® 16 AWG 93341603 3 8.8 93341604 4 9.4 93341605 5 10.2 93341607 7 10.9 93341609 9 12.5 93341612 12 14.7 93341618 18 16.9 93341625 25 19.6

item no. no. of conductors incl. ground

nominal outer-ø inch mm

cable weight

≈ lbs/mft

item no. no. of conductors incl. ground

nominal outer-ø inch mm

cable weight

≈ lbs/mft

item no. no. of conductors incl. ground

nominal outer-ø inch mm

cable weight

≈ lbs/mft

® 14 AWG 93341403 3 9.9 93341404 4 10.7 93341405 5 11.5 93341407 7 12.4 93341412 12 16.8 93341418 18 19.4 93341425 25 23.5 ® 12 AWG 93341203 3 10.8 93341204 4 11.8 93341205 5 12.9

® 10 AWG 93341003 3 14.3 93341004 4 14.4 93341005 5 16.3 93341007 7 17.6 ® 8 AWG 93340804 4 19.3 ® 6 AWG 93340604 4 23.2 ® 4 AWG 93340404 4 27.9 ® 2 AWG 93340204 4 32.3

Other dimensions and colors are possible on request.

0.324 0.348 0.373 0.400 0.455 0.504 0.617 0.710 0.345 0.372 0.400 0.430 0.492 0.579 0.664 0.770

71 85 95

120 149 185 270 365

83

100 116 145 187 245 335 445

0.388 0.420 0.454 0.490 0.662 0.764 0.924 0.427 0.464 0.506

108 131 155 190 350 482 701

145 178 210

0.562 0.568 0.643 0.695 0.759 0.915 1.097 1.271

190 250 350 408

447

672

993

1455

Construction: Conductor: bare copper strands class K (30 AWG multiple strands) Insulation: special formulated PVC/Nylon Color code: black conductors with consecutive white numbers; green-yellow earth wire from 3 conductors Stranding: in layers Wrapping: fleece tape Screen: tinned copper braiding (85% coverage) Jacket material: special oil resistant pressure extruded PVC Jacket color: black

Outstanding features: ä flexible stranding for easy installation ä oil resistant meeting UL Oil Res I and II ä NFPA 79 for Industrial Machinery ä UL TC-ER (exposed runs) ä CSA approved for TC ä Submersible pump (14 AWG ≥, 3 thru 7 cond.) ä WTTC: Wind turbine tray cable

Technical data: Voltage: UL-AWM / (UL) / CSA: 600 V (UL) WTTC: 1000 V Testing voltage: 2000 V Min. bending radius fixed installation: 6 x O.D. free movement: 8 x O.D. Temperature: UL-AWM: (UL) / CSA: up to +105°C up to +90°C static: -40°C Burning characteristics: (UL) FT4 and CSA FT1, FT2, FT4 Oil resistance I + II: yes Sunlight resistance: yes Exposed Runs: yes Cold bend test: -40°C Direct Burial: yes Machinery Area: yes Absence of acc. to RoHS directive of the European Union harmful substances: see page O/30 in full line catalog

Marking for TR 600 S CY 93341604: SAB NORTH AMERICA TR 600 S CY 93341604 16 AWG/ 4C (UL) TC-ER 90C DRY 75C WET 600V SUN RES DIR BUR OIL RES I/II OR WTTC 1000V OR MTW "FLEXING" OR DP-1 OR AWM 2586 105°C CSA CIC-TC PVC/N 90°C DRY 75°C WET 600V -25°C SR FT4 OR AWM I/II A/B 90C 1000V FT4 RoHS C

AWM I/II A/B 90C 1000V FT4 RoHS C

TR 600 S CY is a multi-conductor, UL & CSA approved shielded flexible tray cable. It is rated UL TC-ER, MTW, AWM and CSA CIC/TC for 600 V, 90°C and UL WTTC and CSA AWM 1000V. TR 600 S CY black is UV, oil resistant (Oil Res I & II) and is submersible pump rated (3-7 cond.). This cable can be used without conduit (exposed runs). The reduced outer diameter permits easy handling and installation in confined areas. TR 600 S CY shielded tray cable is designed for use in all electrical equipment in dry, damp and wet conditions. Recommended applications are machine tools, control systems, assembly lines, CNC machining centers, grinding machines, bottling equipment, data processing equipment and connections between control panels and machines. TR 600 S CY is permitted to be used in hazardous (classified) locations Class I, Division 2 per NEC Article 501.4 (B) and is UL Type TC in acc. to UL standard 1277 and NEC Article 336 (392, 501). Additional uses include wind turbine power and control cable intended to be installed in cable trays or raceways within a wind turbine generator and NFPA 79 Machine areas.

33C

866-722-2974 • www.sabcable.com

Page 10: TRAY CABLES FOR INDUSTRIAL PLANT INSTALLATIONS THE RIGHT ... · TR 600 HD is a severe duty motor supply cable for use in applications that require tray cable ratings, flexibility,

® 18 AWG 93351802* 2 7.3 93351803 3 7.6 93351804 4 8.2 93351805 5 8.9 93351807 7 9.6 93351809 9 11.0 93351812 12 12.2 93351818 18 15.1 93351825 25 17.4 93351850 50 23.9 ® 16 AWG 93351602* 2 7.8 93351603 3 8.2 93351604 4 8.8 93351605 5 9.6 93351607 7 10.5 93351608 8 11.2 93351609 9 12.0 93351612 12 13.4 93351616 16 15.6 93351618 18 16.4

item no. no. of conductors incl. ground

nominal outer-ø inch mm

cable weight

≈ lbs/mft

item no. no. of conductors incl. ground

nominal outer-ø inch mm

cable weight

≈ lbs/mft

item no. no. of conductors incl. ground

nominal outer-ø inch mm

cable weight

≈ lbs/mft

® 16 AWG 93351619 19 16.4 93351625 25 18.9 93351634 34 22.5 93351641 41 24.0 93351650 50 26.0 ® 14 AWG 93351402* 2 8.8 93351403 3 9.2 93351404 4 10.1 93351405 5 10.9 93351407 7 12.0 93351409 9 14.7 93351412 12 16.4 93351418 18 18.9 93351425 25 23.0 ® 12 AWG 93351202* 2 9.8 93351203 3 10.2 93351204 4 11.2 93351205 5 12.2 93351207 7 13.4

® 10 AWG 93351003 3 12.4 93351004 4 14.4 93351005 5 15.7 93351007 7 17.1 ® 8 AWG 93350803 3 16.8 93350804 4 18.5 93350805 5 21.0 ® 6 AWG 93350603 3 19.4 93350604 4 22.3 93350605 5 24.2 ® 4 AWG 93350403 3 24.5 93350404 4 26.9 93350405 5 29.9 ® 2 AWG 93350203 3 28.3 93350204 4 29.5 93350205 5 34.6

Other dimensions and colors are possible on request. *2 conductor cables are rated UL TC only

0.286 0.300 0.324 0.349 0.376 0.432 0.480 0.596 0.686 0.940 0.306 0.321 0.348 0.376 0.412 0.440 0.473 0.527 0.613 0.646

45 55 67 79

100 125 157 244 319 622

52 70 81 96

126 137 152 196 273 300

0.646 0.746 0.884 0.945 1.025 0.346 0.364 0.396 0.430 0.472 0.578 0.644 0.744 0.904 0.385 0.403 0.440 0.479 0.526

310 395 544 654 756

65 88

112 130 169 236 297 417 596

99

120 150 189 240

0.487 0.568 0.618 0.674 0.662 0.728 0.826 0.765 0.879 0.954 0.966 1.061 1.179 1.114 1.160 1.363

179 248 298 403

309 388 465

443 580 717

696 845

1035

977 1215 1575

Marking for TR 600 S 93351641: SAB NORTH AMERICA TR 600 S 93351641 16 AWG/41C (UL) TC-ER 90C DRY 75C WET 600V SUN RES DIR BUR OIL RES I/II OR WTTC 1000V OR MTW "FLEXING" OR DP-1 OR AWM 2586 CSA CIC-TC PVC/N 90°C DRY 75°C WET 600V -25°C SR FT4 OR AWM I/II A/B 90C 1000V FT4 RoHS C

-25°C SR FT4 OR AWM I/II A/B 90C 1000V FT4 RoHS C

TR 600 S gray is a multi-conductor, UL & CSA approved flexible tray cable. It is rated UL TC-ER, MTW, AWM and CSA CIC/TC for 600 V, 90°C and UL WTTC and CSA AWM 1000V. TR 600 S gray is UV, oil resistant (Oil Res I & II) and is submersible pump rated (3-7 cond.). This cable can be used without conduit (exposed runs). The reduced outer diameter permits easy handling and installation in confined areas. TR 600 S gray tray cable is designed for use in all electrical equipment in dry, damp and wet conditions. Recommended applications are machine tools, control systems, assembly lines, CNC machining centers, grinding machines, bottling equipment, data processing equipment and connections between control panels and machines. TR 600 S gray is permitted to be used in hazardous (classified) locations Class I, Division 2 per NEC Article 501.4 (B) and is UL Type TC in acc. to UL standard 1277 and NEC Article 336 (392, 501). Additional uses include wind turbine power and control cable intended to be installed in cable trays or raceways within a wind turbine generator and NFPA 79 Machine areas.

Construction: Conductor: bare copper strands class K (30 AWG multiple strands) Insulation: special formulated PVC/Nylon Color code: black conductors with consecutive white numbers; green-yellow earth wire from 3 conductors Stranding: in layers Jacket material: special oil resistant pressure extruded PVC Jacket color: gray

Outstanding features: ä flexible stranding for easy installation ä oil resistant meeting UL Oil Res I and II ä NFPA 79 for Industrial Machinery ä UL TC-ER (exposed runs) ä CSA approved for TC ä Submersible pump (14 AWG ≥, 3 thru 7 cond.) ä WTTC: Wind turbine tray cable

Technical data: Voltage: UL-AWM / (UL) / CSA: 600 V (UL) WTTC: 1000 V Testing voltage: 2000 V Min. bending radius fixed installation: 4 x O.D. free movement: 6 x O.D. Temperature: UL-AWM: (UL) / CSA: up to +105°C up to +90°C static: -40°C Burning characteristics: (UL) FT4 and CSA FT1, FT2, FT4 Oil resistance I + II: yes Sunlight resistance: yes Exposed Runs: yes Cold bend test: -40°C Direct Burial: yes Machinery Area: yes Absence of acc. to RoHS directive of the European Union harmful substances: see page O/30

33C

10

S TRAY CABLES TR 600 S gray Type TC-ER, MTW, WTTC, & CSA Approved UV and Oil resistant 90°C flexible tray cable

866-722-2974 • www.sabcable.com

Page 11: TRAY CABLES FOR INDUSTRIAL PLANT INSTALLATIONS THE RIGHT ... · TR 600 HD is a severe duty motor supply cable for use in applications that require tray cable ratings, flexibility,

11

S TRAY CABLES TR 600 S CY gray Type TC-ER, MTW, WTTC, & CSA Approved UV and oil resistant 90°C shielded flexible tray cable

® 18 AWG 93361803 3 8.2 93361804 4 8.8 93361805 5 9.5 93361807 7 10.2 93361809 9 11.6 93361812 12 12.8 93361818 18 15.7 93361825 25 18.0 ® 16 AWG 93361603 3 8.8 93361604 4 9.4 93361605 5 10.2 93361607 7 10.9 93361609 9 12.5 93361612 12 14.7 93361618 18 16.9 93361625 25 19.6

item no. no. of conductors incl. ground

nominal outer-ø inch mm

cable weight

≈ lbs/mft

item no. no. of conductors incl. ground

nominal outer-ø inch mm

cable weight

≈ lbs/mft

item no. no. of conductors incl. ground

nominal outer-ø inch mm

cable weight

≈ lbs/mft

® 14 AWG 93361403 3 9.9 93361404 4 10.7 93361405 5 11.5 93361407 7 12.4 93361412 12 16.8 93361418 18 19.4 93361425 25 23.5 ® 12 AWG 93361203 3 10.8 93361204 4 11.8 93361205 5 12.9

® 10 AWG 93361003 3 14.3 93361004 4 14.4 93361005 5 16.3 93361007 7 17.6 ® 8 AWG 93360804 4 19.3 ® 6 AWG 93360604 4 23.2 ® 4 AWG 93360404 4 27.9 ® 2 AWG 93360204 4 32.3

Other dimensions and colors are possible on request.

0.324 0.348 0.373 0.400 0.455 0.504 0.617 0.710 0.345 0.372 0.400 0.430 0.492 0.579 0.664 0.770

71 85 95

120 149 185 270 365

83

100 116 145 187 245 335 445

0.388 0.420 0.454 0.490 0.662 0.764 0.924 0.427 0.464 0.506

108 131 155 190 350 482 701

145 178 210

0.562 0.568 0.643 0.695 0.759 0.915 1.097 1.271

190 250 350 408

447

672

993

1455

Construction: Conductor: bare copper strands class K (30 AWG multiple strands) Insulation: special formulated PVC/Nylon Color code: black conductors with consecutive white numbers; green-yellow earth wire from 3 conductors Stranding: in layers Wrapping: fleece tape Screen: tinned copper braiding (85% coverage) Jacket material: special oil resistant pressure extruded PVC Jacket color: gray

Outstanding features: ä flexible stranding for easy installation ä oil resistant meeting UL Oil Res I and II ä NFPA 79 for Industrial Machinery ä UL TC-ER (exposed runs) ä CSA approved for TC ä Submersible pump (14 AWG ≥, 3 thru 7 cond.) ä WTTC: Wind turbine tray cable

Technical data: Voltage: UL-AWM / (UL) / CSA: 600 V (UL) WTTC: 1000 V Testing voltage: 2000 V Min. bending radius fixed installation: 6 x O.D. free movement: 8 x O.D. Temperature: UL-AWM: (UL) / CSA: up to +105°C up to +90°C static: -40°C Burning characteristics: (UL) FT4 and CSA FT1, FT2, FT4 Oil resistance I + II: yes Sunlight resistance: yes Exposed Runs: yes Cold bend test: -40°C Direct Burial: yes Machinery Area: yes Absence of acc. to RoHS directive of the European Union harmful substances: see page O/30

Marking for TR 600 S CY gray 93361604: SAB NORTH AMERICA TR 600 S CY 93361604 16 AWG/ 4C (UL) TC-ER 90C DRY 75C WET 600V SUN RES DIR BUR OIL RES I/II OR WTTC 1000V OR MTW "FLEXING" OR DP-1 OR AWM 2586 105°C CSA CIC-TC PVC/N 90°C DRY 75°C WET 600V -25°C SR FT4 OR AWM I/II A/B 90C 1000V FT4 RoHS C

SR FT4 OR AWM I/II A/B 90C 1000V FT4 RoHS C

TR 600 S CY gray is a multi-conductor, UL & CSA approved shielded flexible tray cable. It is rated UL TC-ER, MTW, AWM and CSA CIC/TC for 600 V, 90°C and UL WTTC and CSA AWM 1000V. TR 600 S CY gray is UV, oil resistant (Oil Res I & II) and is submersible pump rated (3-7 cond.). This cable can be used without conduit (exposed runs). The reduced outer diameter permits easy handling and installation in confined areas. TR 600 S CY gray shielded tray cable is designed for use in all electrical equipment in dry, damp and wet conditions. Recommended applications are machine tools, control systems, assembly lines, CNC machining centers, grinding machines, bottling equipment, data processing equipment and connections between control panels and machines. TR 600 S CY gray is permitted to be used in hazardous (classified) locations Class I, Division 2 per NEC Article 501.4 (B) and is UL Type TC in acc. to UL standard 1277 and NEC Article 336 (392, 501). Additional uses include wind turbine power and control cable intended to be installed in cable trays or raceways within a wind turbine generator and NFPA 79 Machine areas.

33C

866-722-2974 • www.sabcable.com

Page 12: TRAY CABLES FOR INDUSTRIAL PLANT INSTALLATIONS THE RIGHT ... · TR 600 HD is a severe duty motor supply cable for use in applications that require tray cable ratings, flexibility,

12

S TRAY CABLES TR 600 Plus Type TC-ER, MTW, WTTC, & CSA Approved UV and Oil resistant 90°C reduced O.D. flexible tray cable

® 18 AWG 95551803 3 7.1 95551804 4 7.7 95551805 5 8.3 95551807 7 9.0 95551809 9 11.0 95551812 12 11.6 95551816 16 12.8 95551818 18 14.3 95551819 19 14.3 95551825 25 16.8 95551827 27 16.9 95551837 37 18.8 95551850 50 23.0 ® 16 AWG 95551603 3 7.6 95551604 4 8.3 95551605 5 9.0 95551607 7 9.7 95551608 8 11.2 95551609 9 12.0 95551612 12 12.6 95551616 16 14.8 95551618 18 15.5

item no. no. of conductors incl. ground

nominal outer-ø inch mm

cable weight

≈ lbs/mft

item no. no. of conductors incl. ground

nominal outer-ø inch mm

cable weight

≈ lbs/mft

® 16 AWG 95551619 19 15.5 95551625 25 18.4 95551627 27 18.4 95551637 37 21.5 95551641 41 23.0 95551650 50 25.1 95551661 61 26.5

® 14 AWG 95551403 3 8.5 95551404 4 9.2 95551405 5 10.1 95551407 7 11.8 95551409 9 14.3 95551412 12 15.1 95551418 18 17.5 95551425 25 21.9 ® 12 AWG 95551203 3 9.8 95551204 4 10.7 95551205 5 11.7 95551207 7 14.6

0.280 0.303 0.327 0.354 0.433 0.457 0.504 0.563 0.563 0.661 0.665 0.740 0.906

0.299 0.327 0.354 0.382 0.441 0.472 0.496 0.583 0.610

50 60 71 88

117 137 175 210 216 275 292 380 533

62 76 90

113 134 151 179 246 272

0.610 0.724 0.724 0.846 0.906 0.988 1.043 0.335 0.362 0.398 0.465 0.563 0.594 0.689 0.862 0.386 0.421 0.461 0.575

283 359 382 535 595 699 827

84 103 123 164 225 269 381 542

117 145 175 251

item no. no. of conductors incl. ground

nominal outer-ø inch mm

cable weight

≈ lbs/mft

® 10 AWG 95551003 3 11.6 95551004 4 12.7 95551005 5 14.8 95551007 7 17.4 ® 8 AWG 95550804 4 17.3 95550805 5 19.0 ® 6 AWG 95550604 4 20.6 95550605 5 23.8 ® 4 AWG 95550404 4 26.1 95550405 5 28.9 ® 2 AWG 95550204 4 30.2 95550205 5 33.5

0.457 0.500 0.583 0.685

0.681 0.748

0.811 0.937

1.028 1.138 1.189 1.319

174 218 280 374

374 451

549 703

884

1074

1266 1.533

600V c(UL) Type CIC 90°C dry 600V FT1 FT2 FT4 C

TR 600 Plus is a multi-conductor, 600 V, 90°C, UL recognized and CSA approved, UV and oil resistant flexible tray cable. It is a reduced diameter and more flexible tray cable. It is also machine tool cable for use as specified in the National Electrical Code (NFPA 70) and in the National Fire Protection Association Electrical Standard for industrial machinery (NFPA 79). This cable can be used without conduit (exposed runs). The reduced outer diameter permits easy handling and installation in confined areas. Our specially designed PVC jacket passes the stringent requirements of the VDE test 0281 part 1 and HD 21.1 oil test providing the best oil resistance available for a PVC jacket. TR 600 Plus tray cable is designed for use in all electrical equipment in dry, damp and wet conditions. Recommended applications are machine tools, control systems, assembly lines, CNC machining centers, grinding machines, bottling equipment, data processing equipment and connections between control panels and machines. TR 600 Plus is permitted to be used in hazardous (classified) locations Class I, Division 2 per NEC Article 501.4 (B), UL Type TC is in acc. to UL standard 1277 and NEC Article 336 (392, 501). Wind turbine power and control cable is intended to be installed in cable trays or raceways within a wind turbine generator. MTW listed cables can be used in NFPA 79 Machine areas.

Construction: Conductor: bare copper finely stranded, class 5 Insulation: special formulated PVC/Nylon Color code: black conductors with consecutive white numbers; green-yellow earth wire from 3 conductors Stranding: in layers Jacket material: special sunlight and oil resistant PVC Jacket color: black

Outstanding features: ä improved flexibility

ä flexible cable for cable tray use even where sunlight resistance and open wiring is required ä NFPA 79 for Industrial Machinery ä WTTC: UL subject 2277 ä TC: UL standard 1277 ä (UL)/(cUL) listed

Technical data: Voltage: UL-AWM / (UL) / c(UL): 600 V (UL) WTTC / CSA-AWM: 1000 V Testing voltage: 6000 V Min. bending radius fixed installation: 4 x O.D. free movement: 5 x O.D. Radiation resistance: 8 x 107 cJ/kg Temperature: UL-AWM: (UL) / c(UL) / CSA-AWM: up to +105°C up to +90°C static: -25°C Burning characteristics: (UL) FT4 and c(UL) FT1, FT2, FT4 and CSA FT1, FT2 Oil resistance I: yes Sunlight resistance: yes Exposed Runs: yes Direct Burial: yes Machinery Area: yes Absence of acc. to RoHS directive of the European Union harmful substances: see page O/30

33CMarking for TR 600 Plus 95551804: A BRÖCKSKES · D-VIERSEN · TR 600 Plus 18AWG/4 95551804 (UL) Type TC-ER 90°C 600V, Oil Resistant I, Sunlight Resistant, Direct Burial, FT4 (UL) WTTC 90°C 1000V (UL) MTW 600 V AWM Style 21179 600 V c(UL) Type CIC 90°C dry 600V FT1, FT2, FT4 CSA AWM I/II

A/B 90°C 1000V FT1, FT2 C

866-722-2974 • www.sabcable.com

Page 13: TRAY CABLES FOR INDUSTRIAL PLANT INSTALLATIONS THE RIGHT ... · TR 600 HD is a severe duty motor supply cable for use in applications that require tray cable ratings, flexibility,

13

S TRAY CABLES TR 600 CY Plus Type TC-ER, MTW, WTTC, & CSA Approved Shielded UV and Oil resistant 90°C reduced O.D. flexible tray cable

® 18 AWG 95561803 3 7.6 95561804 4 8.2 95561805 5 8.8 95561807 7 9.5 95561809 9 11.7 95561812 12 12.3 95561816 16 14.3 95561818 18 15.2 95561819 19 15.2 95561825 25 17.8 95561827 27 17.8 95561837 37 19.7 95561850 50 23.9 ® 16 AWG 95561603 3 8.1 95561604 4 8.8 95561605 5 9.5 95561607 7 10.2 95561608 8 11.9 95561609 9 12.7 95561612 12 14.1 95561616 16 15.7

item no. no. of conductors incl. ground

nominal outer-ø inch mm

cable weight

≈ lbs/mft

item no. no. of conductors incl. ground

nominal outer-ø inch mm

cable weight

≈ lbs/mft

® 16 AWG 95561618 18 16.4 95561619 19 16.4 95561625 25 19.3 95551627 27 19.3 95551637 37 22.4 95551641 41 23.9 95551650 50 26.0 95551661 61 27.4 ® 14 AWG 95561403 3 9.0 95561404 4 9.7 95561405 5 10.8 95561407 7 12.5 95561409 9 15.2 95561412 12 16.0 95561418 18 18.4 95561425 25 22.8 ® 12 AWG 95561203 3 10.3 95561204 4 11.4 95561205 5 12.4 95561207 7 15.5

® 10 AWG 95561003 3 12.3 95561004 4 14.2 95561005 5 15.7 95561007 7 18.3 ® 8 AWG 95560804 4 18.2 95560805 5 19.9 ® 6 AWG 95560604 4 22.5 95560605 5 24.7 ® 4 AWG 95560404 4 27.0 95560405 5 29.8 ® 2 AWG 95560204 4 31.1 95560205 5 34.4

0.299 0.323 0.346 0.374 0.461 0.484 0.563 0.598 0.598 0.701 0.701 0.776 0.941 0.319 0.346 0.374 0.402 0.469 0.500 0.555 0.618

58 67 79 97

138 159 214 247 252 323 339 431 603

68 83 98

122 155 172 217 286

0.646 0.646 0.760 0.760 0.882 0.941 1.024 1.079

0.354 0.382 0.425 0.492 0.598 0.630 0.724 0.898 0.406 0.449 0.488 0.610

312 320 411 433 592 661 769 898

88

110 139 182 258 307 424 599

120 159 189 286

item no. no. of conductors incl. ground

nominal outer-ø inch mm

cable weight

≈ lbs/mft 0.484 0.559 0.618 0.720 0.717 0.783 0.886 0.972 1.063 1.173 1.224 1.354

181 244 308 409

393 474

595 726

878

1076

1235 1509

Construction: Conductor: bare copper finely stranded, class 5 Insulation: special formulated PVC/Nylon Color code: black conductors with consecutive white numbers; green-yellow earth wire from 3 conductors Stranding: in layers Screen: double screen, alu-foil, tinned copper braiding Jacket material: special sunlight and oil resistant PVC Jacket color: black

Outstanding features: ä improved flexibility

ä flexible cable for cable tray use even where sunlight resistance and open wiring is required ä NFPA 79 for Industrial Machinery ä WTTC: UL subject 2277 ä TC: UL standard 1277 ä (UL)/(cUL) listed

Technical data: Voltage: UL-AWM / (UL) / c(UL): 600 V (UL) WTTC / CSA-AWM: 1000 V Testing voltage: 6000 V Min. bending radius fixed installation: 5 x O.D. free movement: 10 x O.D. Radiation resistance: 8 x 107 cJ/kg Temperature: UL-AWM: (UL) / c(UL) / CSA-AWM: up to +105°C up to +90°C static: -25°C Burning characteristics: (UL) FT4 and c(UL) FT1, FT2, FT4 and CSA FT1, FT2 Oil resistance I: yes Sunlight resistance: yes Exposed Runs: yes Direct Burial: yes Machinery Area: yes Absence of acc. to RoHS directive of the European Union harmful substances: see page O/30

Marking for TR 600 CY Plus 95561804: A BRÖCKSKES · D-VIERSEN · TR 600 CY Plus 18AWG/4 95561804 TFFN (UL) Type TC-ER 90°C 600V, Oil Resistant I, Sunlight Resistant, Direct Burial, FT4 (UL) WTTC 90°C 1000V (UL) MTW 600 V AWM Style 21179 600 V c(UL) Type CIC 90°C dry 600V FT1, FT2, FT4 CSA Type CIC Shielded 90°C dry 600V FT1, FT2, FT4 C

Type CIC SHIELDED 90°C dry 600V FT1 FT2 FT4 C

TR 600 CY Plus is a shielded multi-conductor, 600 V, 90°C, UL recognized and CSA approved, UV and oil resistant flexible tray cable. It is a reduced diameter and more flexible tray cable. It is also machine tool cable for use as specified in the National Electrical Code (NFPA 70) and in the National Fire Protection Association Electrical Standard for industrial machinery (NFPA 79). This cable can be used without conduit (exposed runs). The reduced outer diameter permits easy handling and installation in confined areas. Our specially designed PVC jacket passes the stringent requirements of the VDE test 0281 part 1 and HD 21.1 oil test providing the best oil resistance available for a PVC jacket. TR 600 CY Plus tray cable is designed for use in all electrical equipment in dry, damp and wet conditions. Recommended applications are machine tools, control systems, assembly lines, CNC machining centers, grinding machines, bottling equipment, data processing equipment and connections between control panels and machines. TR 600 CY Plus is permitted to be used in hazardous (classified) locations Class I, Division 2 per NEC Article 501.4 (B), UL Type TC is in acc. to UL standard 1277 and NEC Article 336 (392, 501). Wind turbine power and control cable is intended to be installed in cable trays or raceways within a wind turbine generator. MTW listed cables can be used in NFPA 79 Machine areas.

33C

866-722-2974 • www.sabcable.com

Page 14: TRAY CABLES FOR INDUSTRIAL PLANT INSTALLATIONS THE RIGHT ... · TR 600 HD is a severe duty motor supply cable for use in applications that require tray cable ratings, flexibility,

® 18 AWG 8501803 3 9.2 8501804 4 10.0 8501805 5 11.7 8501807 7 12.6 ® 16 AWG 8501603 3 10.0 8501604 4 10.7 8501605 5 12.6 8501607 7 13.6 ® 14 AWG 8501403 3 13.7 8501404 4 14.8 8501405 5 16.7 8501407 7 18.0 ® 12 AWG 8501203 3 15.6 8501204 4 16.3 8501205 5 18.2 8501207 7 19.6

item no. no. of conductors incl. ground

nominal outer-ø inch mm

cable weight

≈ lbs/mft

item no. no. of conductors incl. ground

nominal outer-ø inch mm

cable weight

≈ lbs/mft

® 10 AWG 8501003 3 17.7 8501004 4 18.8 8501005 5 20.8 8501007 7 21.6 ® 8 AWG 8500804 4 25.1 ® 6 AWG 8500604 4 28.4 ® 4 AWG 8500404 4 32.4 ® 2 AWG 8500204 4 36.6

Other dimensions and colors are possible on request.

0.363 0.394 0.462 0.495 0.392 0.422 0.497 0.535 0.541 0.584 0.656 0.708 0.614 0.640 0.716 0.773

77 95

133 157

96

111 159 192

170 208 264 324

232 329 329 418

0.696 0.742 0.819 0.850 0.990 1.120 1.277 1.442

307 378 445 544

623

828

1174

1578

Marking for TR 850 S 8501205: SAB NORTH AMERICA 12AWG/5C (UL) TYPE TC-ER 90C DRY 75C WET 600V SUN RES DIR BUR OIL RES I/II OR TYPE STOOW 105C 600V OR WTTC 1000V OR C(UL) CIC-TC PVC 600V FT4 --- CSA STOOW 105C 600V FT1 OR AWM I/II A/B 105C 1000V FT4 C

600V c(UL) Type CIC 90°C dry 600V FT1 FT2 FT4 C

TR 850 S is a multi-conductor, 600V, 90°C, UL TC-ER, UV and oil resistant flexible tray cable. It is also UL and CSA Type STOOW flexible cord for use as specified in the National Electrical Code (NFPA 70) and in the National Fire Protection Association Electrical Standard for industrial machinery (NFPA 79). Flexible cords shall be used for connection of portable lamps, portable and mobile signs or appliances, wiring of cranes and hoists. Our specially designed PVC jacket passes the stringent requirements of UL Oil Res I & II oil tests providing the best oil resistance available for a PVC jacket. TR 850 S tray cables are designed for use in all electrical equipment in dry damp and wet conditions. Recommended applications are machine tools, control systems, assembly lines, CNC machining centers, grinding machines, bottling equipment, data processing equipment and connections between control panels and machines. TR 850 S is permitted in hazardous (classified) locations Class I, Division 2 per NEC Article 501.4 (B), UL Type TC is in acc. to UL standard 1277 and NEC Article 336 (392, 501). The STOOW listed cable could be used in NFPA 79 Machinery Area.

Construction: Conductor: bare copper strands class K Insulation: special formulated PVC Color code: 3c-black, white, green/yellow; 4c-black,white, red, green/yellow; 5c-black, white, red, brown, green/yellow; 7c-black numbered plus green/yellow ground Stranding: in layers Jacket material: special sunlight and oil resisistant PVC Jacket color: black

Outstanding features: ä flexible cable for cable tray use even where sunlight resistance is required ä UL STOOW / CSA STOOW ä Class I Div I for flexible use only

Technical data: Voltage: (UL) TC / STOOW / CSA STOOW: 600 V (UL) WTTC / CSA AWM: 1000 V Testing voltage: 2000 V Min. bending radius fixed installation: 4 x O.D. free movement: 6 x O.D. Temperature: UL / CSA STOOW: (UL) / c(UL): up to +105°C up to +90°C static: -40°C Burning characteristics: (UL) FT4 and c(UL) FT1, FT2, FT4 Oil resistance I & II: yes Sunlight resistance: yes Exposed Runs: yes Direct Burial: yes Machinery Area: yes Absence of acc. to RoHS directive of the European Union harmful substances: see page O/30

33C

14

S TRAY CABLES TR 850 S Type TC-ER, STOOW, & CSA Approved UV and Oil resistant 90°C flexible tray cable- flexible cord

866-722-2974 • www.sabcable.com

Page 15: TRAY CABLES FOR INDUSTRIAL PLANT INSTALLATIONS THE RIGHT ... · TR 600 HD is a severe duty motor supply cable for use in applications that require tray cable ratings, flexibility,

15

S TRAY CABLES TRAY HD TPE Type TC-ER, WTTC, & CSA Approved Heavy duty tray cable

® 18 AWG 94441803 3 7.5 94441805 5 8.7 94441807 7 9.4 94441811 11 11.8 94441812 12 12.1 94441819 19 14.8 94441825 25 17.2 94441833 33 18.7 94441842 42 20.7 94441849 49 23.0 94441865 65 25.6

item no. no. of conductors incl. ground

nominal outer-ø inch mm

cable weight

≈ lbs/mft

item no. no. of conductors incl. ground

nominal outer-ø inch mm

cable weight

≈ lbs/mft

® 16 AWG 94441603 3 8.2 94441605 5 10.4 94441607 7 13.7 94441611 11 14.1 94441612 12 16.1 94441619 19 16.3 94441625 25 18.7 94441633 33 20.7 94441642 42 24.1 94441649 49 25.5 94441665 65 28.5

Other dimensions and colors are possible on request.

0.295 0.343 0.370 0.465 0.476 0.583 0.677 0.736 0.815 0.906 1.008

55 79

100 149 157 247 319 391 498 607 675

0.323 0.409 0.539 0.555 0.634 0.642 0.736 0.815 0.949 1.004 1.122

70 96

166 191 196 307 395 475 612 748 998

*For red conductors add R at end of P/N. i.e. 94441803R

Construction: Conductor: bare copper strands class K Insulation: special formulated PVC/Nylon Color code: blue with numerical print* one with white-blue conductor and one green/yellow earth wire** *Alpha-Numeric Alternate and Inverted, ie: 1-ONE Stranding: in layers Jacket material: TPE Jacket color: gray (also available in black)

Outstanding features: ä heavy duty tray cable and control and instrumentation cable ä UL-AWM recognized for 105°C ä extremely oil resistant ä WTTC: UL subject 2277 ä TC: UL standard 1277 ä CSA listed ä NFPA 79 for Industrial Machinery ä c(UL) CIC-TC FT4

Technical data: Voltage: UL-AWM / (UL) / c(UL): 600 V (UL) WTTC: 1000 V Testing voltage: 2000 V Min. bending radius: 7.5 x O.D. Temperature: UL-AWM: UL) / c(UL)/ CSA-AWM: up to +105°C up to +90°C static: -40°C Burning characteristics: (UL) FT4 and c(UL) FT1, FT2, FT4 Oil resistance I & II: yes Exposed Runs: yes Cold bend test: -40°C Absence of acc. to RoHS directive of the European Union harmful substances: see page O/30 Alt. color code: ** Add B at the end of Part No. for black conductors with numbers; and green-yellow earth wire ** Add R at the end of Part No. for red conductors with numbers; one white-red conductor and green-yellow earth wire

Marking for TRAY HD TPE 94441842: A NORTH AMERICA TRAY HD TPE 18 AWG 42c P/N 94441842 (UL) TC-ER 90C DRY 75C WET 600V OIL RES I/II SUN RES DIR BUR OR WTTC 1000V OR AWM 21270 105C 600V OR c (UL) CIC-TC PVC/N 600V FT4 CSA AWM I/II A/B 90C 600V FT4 RoHS C

600V FT4 CSA AWM I/II A/B 90C 600V FT4 RoHS C

TRAY HD TPE is a severe duty motor supply cable with blue conductor or red conductors for use in applications that require cables to be identified for AC or DC circuits. The TPE jacket provides excellent flexibility, chemical resistance and extreme oil resistance. This cable can be used without conduit (exposed runs).TRAY HD TPE is permitted to be used in hazardous (classified) locations Class I, Division 2 per NEC Article 501.4 (B), UL Type TC is in acc. to UL standard 1277 and NEC Article 336.Wind turbine power and control cable is intended to be installed in cable trays or raceways within a wind turbine generator.

33C

qqAvailable with black jacket as well as red conductors.

866-722-2974 • www.sabcable.com

Page 16: TRAY CABLES FOR INDUSTRIAL PLANT INSTALLATIONS THE RIGHT ... · TR 600 HD is a severe duty motor supply cable for use in applications that require tray cable ratings, flexibility,

*For blue conductors add B at end of P/N, for red add an R. i.e. 32401404B

® 18 AWG 32301803 3 7.6 32301804 4 8.2 32301805 5 8.9 32301807 7 9.6 32301812 12 12.2 32301818 18 15.1 32301825 25 17.4 ® 16 AWG 32301603 3 8.2 32301604 4 8.8 32301605 5 9.6 32301607 7 10.5 32301612 12 13.4 32301618 18 16.4 32301625 25 18.9

item no. no. of conductors incl. ground

nominal outer-ø inch mm

cable weight

≈ lbs/mft

item no. no. of conductors incl. ground

nominal outer-ø inch mm

cable weight

≈ lbs/mft

item no. no. of conductors incl. ground

nominal outer-ø inch mm

cable weight

≈ lbs/mft

® 14 AWG 32301403 3 9.2 32301404 4 10.1 32301407 7 12.0 32301412 12 16.4 ® 12 AWG 32301203 3 10.2 32301204 4 11.2 32301205 5 12.2 32301207 7 13.4 32301212 12 18.3 ® 10 AWG 32301003 3 12.9 32301004 4 15.0 32301005 5 16.3

® 8 AWG 32300804 4 19.2 32300805 5 21.0 ® 6 AWG 32300603 3 19.5 32300604 4 22.3 ® 4 AWG 32300404 4 26.9 32300405 5 29.9 ® 2 AWG 32300204 4 31.4 32300205 5 34.6 ® 1 AWG 32300104 4 35.6

Other dimensions and colors are possible on request.

0.300 0.324 0.349 0.376 0.480 0.596 0.686 0.321 0.348 0.376 0.412 0.527 0.646 0.746

55 67 79

100 157 244 319

70 81 96

166 196 300 395

0.364 0.396 0.472 0.644 0.403 0.440 0.479 0.526 0.719 0.506 0.590 0.642

88 92

169 297

120 150 182 240 420

179 248 298

0.756 0.826 0.767 0.879 1.061 1.179 1.235 1.363 1.403

385 465

426 580

845

1035

1278 1575

1605

Marking for TR 600 HD 32301604: A NORTH AMERICA TR 600 HD 16 AWG 4c P/N 32301604 (UL) TC-ER 90C DRY 75C WET 600V OIL RES I/II SUN RES DIR BUR OR WTTC 1000V OR AWM 21270 105C 600V OR c (UL) CIC-TC PVC/N 600V FT4 CSA AWM I/II A/B 90C 600V FT4 RoHS C

FT4 CSA AWM I/II A/B 90C 600V FT4 RoHS C

TR 600 HD is a severe duty motor supply cable for use in applications that require tray cable ratings, flexibility, chemical resistance and extreme oil resistance. This cable can be used without conduit (exposed runs). TR 600 HD is permitted to be used in hazardous (classified) locations Class I, Division 2 per NEC Article 501.4 (B), UL Type TC is in acc. to UL standard 1277 and NEC Article 336. Wind turbine power and control cable is intended to be installed in cable trays or raceways within a wind turbine generator.

Construction: Conductor: bare copper strands class K Insulation: special formulated PVC/Nylon Color code: black with numerical print* and one green/yellow earth wire** *Alpha-Numeric Alternate and Inverted, ie: 1-ONE Stranding: in layers Jacket material: TPE Jacket color: orange (also available in gray or black)

Outstanding features: ä heavy duty tray cable and control and instrumentation cable ä UL-AWM recognized for 105°C ä extremely oil resistant ä WTTC: UL subject 2277 ä TC: UL standard 1277 ä CSA listed ä NFPA 79 for Industrial Machinery ä c(UL) CIC-TC FT4

Technical data: Voltage: UL-AWM / (UL) / c(UL): 600 V (UL) WTTC: 1000 V Testing voltage: 2000 V Min. bending radius: 7.5 x O.D. Temperature: UL-AWM: (UL) / c(UL)/ CSA-AWM: up to +105°C up to +90°C static: -40°C Burning characteristics: (UL) FT4 and c(UL) FT1, FT2, FT4 Oil resistance I & II: yes Exposed Runs: yes Cold bend test: -40°C Absence of acc. to RoHS directive of the European Union harmful substances: see page O/30 Alt. color code: ** Add B at the end of Part No. for blue conductors with numbers; one white-blue conductor and green-yellow earth wire ** Add R at the end of Part No. for red conductors with numbers; one white-red conductor and green-yellow earth wire

33C

qqAvailable with gray

or black jacket as well as blue and red conductors.

16

S TRAY CABLES TR 600 HD Type TC-ER, WTTC, & CSA Approved Heavy duty tray cable

866-722-2974 • www.sabcable.com

Page 17: TRAY CABLES FOR INDUSTRIAL PLANT INSTALLATIONS THE RIGHT ... · TR 600 HD is a severe duty motor supply cable for use in applications that require tray cable ratings, flexibility,

17

S TRAY CABLES TR 600 C HD Type TC-ER, WTTC, & CSA Approved Shielded heavy duty tray cable

*For blue conductors add B at end of P/N, for red add an R. i.e. 32301404B

® 18 AWG 32401803 3 9.7 32401804 4 10.4 32401805 5 10.9 32401807 7 11.6 32401812 12 15.1 32401818 18 17.6 32401825 25 19.7 ® 16 AWG 32401603 3 10.3 32401604 4 10.5 32401605 5 11.7 32401607 7 12.4 32401612 12 16.3 32401618 18 19.1 32401625 25 22.4

item no. no. of conductors incl. ground

nominal outer-ø inch mm

cable weight

≈ lbs/mft

item no. no. of conductors incl. ground

nominal outer-ø inch mm

cable weight

≈ lbs/mft

item no. no. of conductors incl. ground

nominal outer-ø inch mm

cable weight

≈ lbs/mft

® 14 AWG 32401403 3 11.4 32401404 4 12.2 32401407 7 14.8 ® 12 AWG 32401204 4 13.3 32401205 5 15.2 ® 10 AWG 32401004 4 17.7

® 8 AWG 32400804 4 23.6 ® 6 AWG 32400604 4 26.0 ® 4 AWG 32400404 4 30.6 ® 2 AWG 32400204 4 35.1 ® 1 AWG 32400104 4 39.3

Other dimensions and colors are possible on request.

0.385 0.408 0.433 0.460 0.599 0.700 0.783 0.406 0.413 0.460 0.490 0.640 0.750 0.882

99

113 126 151 250 352 449

112 107 154 182 301 425 569

0.450 0.480 0.584 0.523 0.597 0.698

138 149 257

217 272

366

0.930 1.023 1.204 1.382 1.548

579

793

1157

1579

2815

Construction: Conductor: bare copper strands class K Insulation: special formulated PVC/Nylon Color code: black with numerical print* and one green/yellow earth wire** *Alpha-Numeric Alternate and Inverted, ie: 1-ONE Stranding: in layers Inner jacket: PVC, color black Screen: tinned copper braiding, 85% coverage Jacket material: TPE Jacket color: orange (also available in gray or black)

Outstanding features: ä heavy duty tray cable and control and instrumentation cable ä UL-AWM recognized for 105°C ä extremely oil resistant ä WTTC: UL subject 2277 ä TC: UL standard 1277 ä CSA listed ä NFPA 79 for Industrial Machinery ä c(UL) CIC-TC FT4

Technical data: Voltage: UL-AWM / (UL) / c(UL): 600 V (UL) WTTC: 1000 V Testing voltage: 2000 V Min. bending radius: 7.5 x O.D. Temperature: UL-AWM: UL) / c(UL)/ CSA-AWM: up to +105°C up to +90°C static: -40°C Burning characteristics: (UL) FT4 and c(UL) FT1, FT2, FT4 Oil resistance I & II: yes Exposed Runs: yes Cold bend test: -40°C Absence of acc. to RoHS directive of the European Union harmful substances: see page O/30 Alt. color code: ** Add B at the end of Part No. for black conductors with numbers; and green-yellow earth wire ** Add R at the end of Part No. for red conductors with numbers; one white-red conductor and green-yellow earth wire

Marking for TR 600 C HD 32401604: A North America TR 600 C HD 16 AWG/4c P/N 32401604 (UL) TC-ER 90°C DRY, 75°C WET, 600V OIL RES I/II SUN RES DIR BUR OR WTTC 1000V OR AWM 21270 105C 600V OR c(UL) CIC-TC PVC/N 600V FT4 CSA AWM I/II AB 90C 600V FT4 RoHS C

FT4 CSA AWM I/II AB 90C 600V FT4 RoHS C

TR 600 C HD is a shielded severe duty motor supply cable for use in applications that require tray cable ratings, flexibility, chemical resistance and extreme oil resistance. This cable can be used without conduit (exposed runs). TR 600 C HD is permitted to be used in hazardous (classified) locations Class I, Division 2 per NEC Article 501.4 (B), UL Type TC is in acc. to UL standard 1277 and NEC Article 336. Wind turbine power and control cable is intended to be installed in cable trays or raceways within a wind turbine generator.

33C

qqAvailable with gray

or black jacket as well as blue and red conductors.

866-722-2974 • www.sabcable.com

Page 18: TRAY CABLES FOR INDUSTRIAL PLANT INSTALLATIONS THE RIGHT ... · TR 600 HD is a severe duty motor supply cable for use in applications that require tray cable ratings, flexibility,

*For blue conductors add B at end of P/N, for red add an R. i.e. 32401404B

® 18 AWG 32321803 3 7.7 32321804 4 8.3 32321805 5 8.9 32321807 7 10.3 32321812 12 12.2 32321818 18 15.0 32321825 25 18.1 ® 16 AWG 32321603 3 8.5 32321604 4 9.2 32321605 5 10.0 32321607 7 11.6 32321612 12 14.7 32321618 18 17.0 32321625 25 20.8

item no. no. of conductors incl. ground

nominal outer-ø inch mm

cable weight

≈ lbs/mft

item no. no. of conductors incl. ground

nominal outer-ø inch mm

cable weight

≈ lbs/mft

item no. no. of conductors incl. ground

nominal outer-ø inch mm

cable weight

≈ lbs/mft

® 14 AWG 32321403 3 9.2 32321404 4 9.9 32321405 5 10.7 32321407 7 12.6 32321412 12 15.9 ® 12 AWG 32321203 3 10.7 32321204 4 11.6 32321207 7 15.8 32321212 12 18.8 ® 10 AWG 32321003 3 12.9 32321004 4 15.0 32321005 5 16.3

® 8 AWG 32320804 4 19.2 32320805 5 21.0 ® 6 AWG 32320603 3 19.5 32320604 4 22.3 ® 4 AWG 32320404 4 26.9 32320405 5 29.9 ® 2 AWG 32320204 4 31.4 32320205 5 34.6

Other dimensions and colors are possible on request.

0.302 0.325 0.350 0.405 0.480 0.589 0.714 0.336 0.364 0.394 0.458 0.580 0.669 0.817

48 58 75 94

134 214 307

63 77 98

125 204 300 423

0.361 0.391 0.423 0.495 0.625 0.420 0.458 0.621 0.742 0.506 0.590 0.642

82

102 125 169 282

115 145 264 398

179 248 298

0.756 0.826 0.767 0.879 1.061 1.179 1.235 1.363

385 465

426 580

845

1035

1278 1575

Construction: Conductor: bare copper strands class M Insulation: special formulated PVC/Nylon Color code: black with numerical print* and one green/yellow earth wire** *Alpha-Numeric Alternate and Inverted, ie: 1-ONE Stranding: in layers with fleece tape seperator Jacket material: TPE Jacket color: black

Outstanding features: ä heavy duty tray cable and control and instrumentation cable ä UL-AWM 21270 recognized for 105°C ä extremely oil resistant ä WTTC: UL subject 2277 ä TC: UL standard 1277 ä CSA listed ä NFPA 79 for Industrial Machinery ä c(UL) CIC-TC FT4 ä continuous flex applications

Technical data: Voltage: UL-AWM / (UL) / c(UL): 600 V (UL) WTTC: 1000 V Testing voltage: 2000 V Min. bending radius fixed installation: 4 x O.D. free movement: 6 x O.D. continuous flexing: 10 x O.D. Temperature: UL-AWM: (UL) / c(UL)/ CSA-AWM: up to +105°C up to +90°C static: -40°C Cold Bend Test: -40°C Burning characteristics: (UL) Vertical Tray Flame and c(UL) FT1, FT2, FT4 Oil resistance I & II: yes Exposed Runs: yes Absence of acc. to RoHS directive of the European Union harmful substances: see page O/30 in full line catalog Alt. color code: ** Add B at the end of Part No. for Blue Conductors blue conductors with numbers; one white-blue conductor and green-yellow earth wire ** Add R at the end of Part No. for Red Conductors red conductors with numbers; one white-red conductor and green-yellow earth wire

Marking for TR 600 Auto HD 32321604: A NORTH AMERICA TR 600 Auto HD 16AWG/4c P/N 32321604 (UL) TC-ER 90C DRY 75 C WET 600V OIL RES I/II SUN RES DIR BUR OR WTTC 1000V OR AWM 21270 105C 600V OR c (UL) CIC-TC PVC/N 600V FT4 CSA AWM I/II A/B 90C 600V FT4 RoHS C

600V FT4 CSA AWM I/II A/B 90C 600V FT4 RoHS C

TR 600 Auto HD is a severe duty continuous flex motor supply cable for use in applications that require tray cable ratings, flexibility, chemical resistance and extreme oil resistance. This cable can be used without conduit (exposed runs). TR 600 Auto HD is permitted to be used in hazardous (classified) locations Class I, Division 2 per NEC Article 501.4 (B), UL Type TC is in acc. to UL standard 1277 and NEC Article 336. Wind turbine power and control cable is intended to be installed in cable trays or raceways within a wind turbine generator.

qqAvailable with blue or red conductors

33C

18

S TRAY CABLES TR 600 Auto HD Type TC-ER, WTTC, & CSA Approved Continuous flex heavy duty tray cable

866-722-2974 • www.sabcable.com

Page 19: TRAY CABLES FOR INDUSTRIAL PLANT INSTALLATIONS THE RIGHT ... · TR 600 HD is a severe duty motor supply cable for use in applications that require tray cable ratings, flexibility,

19

S TRAY CABLES TR 600 Auto C HD Type TC-ER, WTTC, & CSA Approved Shielded continuous flex heavy duty tray cable

® 18 AWG 32421803 3 8.2 32421804 4 8.8 32421807 7 10.8 32421812 12 12.7 32421818 18 15.5 32421825 25 18.1 ® 16 AWG 32421603 3 9.0 32421604 4 9.8 32421605 5 10.5 32421607 7 12.1 32421612 12 15.2 32421618 18 17.0 32421625 25 22.4

item no. no. of conductors incl. ground

nominal outer-ø inch mm

cable weight

≈ lbs/mft

item no. no. of conductors incl. ground

nominal outer-ø inch mm

cable weight

≈ lbs/mft

item no. no. of conductors incl. ground

nominal outer-ø inch mm

cable weight

≈ lbs/mft

® 14 AWG 32421403 3 9.7 32421404 4 10.4 32421405 5 11.3 32421407 7 13.1 ® 12 AWG 32421204 4 12.1 32421205 5 13.2 ® 10 AWG 32421004 4 15.6 32421005 5 17.1

® 8 AWG 32420804 4 19.9 ® 6 AWG 32420604 4 23.2 ® 4 AWG 32420404 4 27.8 ® 2 AWG 32420204 4 32.1

Other dimensions and colors are possible on request.

0.322 0.345 0.425 0.500 0.609 0.714 0.356 0.384 0.414 0.478 0.600 0.669 0.883

45 85

120 185 260 307

78

100 127 145 245 337 541

0.381 0.411 0.443 0.515 0.478 0.519 0.613 0.673

108 123 147 185

178 210

280 350

0.785 0.914 1.096 1.264

450

630

945

1450

Construction: Conductor: bare copper strands class M Insulation: special formulated PVC/Nylon Color code: black with numerical print* and one green/yellow earth wire** *Alpha-Numeric Alternate and Inverted, ie: 1-ONE Stranding: in layers Wrapping: fleece binder Screen: tinned copper braiding (85% coverage) Separator: tissue tape Jacket material: TPE Jacket color: black

Outstanding features: ä heavy duty tray cable and control and instrumentation cable ä UL-AWM 21270 recognized for 105°C ä extremely oil resistant ä WTTC: UL subject 2277 ä TC: UL standard 1277 ä CSA listed ä NFPA 79 for Industrial Machinery ä c(UL) CIC-TC FT4 ä continuous flex applications

Technical data: Voltage: UL-AWM / (UL) / c(UL): 600 V (UL) WTTC: 1000 V Testing voltage: 2000 V Min. bending radius fixed installation: 5 x O.D. free movement: 10 x O.D. continuous flexing: 12 x O.D. Temperature: UL-AWM: (UL) / c(UL)/ CSA-AWM: up to +105°C up to +90°C static: -40°C Cold Bend Test: -40°C Burning characteristics: (UL) Vertical Tray Flame and c(UL) FT1, FT2, FT4 Oil resistance I & II: yes Exposed Runs: yes Absence of acc. to RoHS directive of the European Union harmful substances: see page O/30 in full line catalog Alt. color code: ** Add B at the end of Part No. for Blue Conductors blue conductors with numbers; one white-blue conductor and green-yellow earth wire ** Add R at the end of Part No. for Red Conductors red conductors with numbers; one white-red conductor and green-yellow earth wire

Marking for TR 600 Auto C HD 32421604: A NORTH AMERICA TR 600 Auto HD 16AWG/4c P/N 32421604 (UL) TC-ER 90C DRY 75 C WET 600V OIL RES I/II SUN RES DIR BUR OR WTTC 1000V OR AWM 21270 105C 600V OR c (UL) CIC-TC PVC/N 600V FT4 CSA AWM I/II A/B 90C 600V FT4 RoHS C

CSA AWM I/II A/B 90C 600V FT4 RoHS C

TR 600 Auto C HD is a shielded severe duty continuous flex motor supply cable for use in applications that require tray cable ratings, flexibility, chemical resistance and extreme oil resistance. This cable can be used without conduit (exposed runs). TR 600 C HD is permitted to be used in hazardous (classified) locations Class I, Division 2 per NEC Article 501.4 (B), UL Type TC is in acc. to UL standard 1277 and NEC Article 336. Wind turbine power and control cable is intended to be installed in cable trays or raceways within a wind turbine generator.

qqAvailable with blue or red conductors

33C

866-722-2974 • www.sabcable.com

Page 20: TRAY CABLES FOR INDUSTRIAL PLANT INSTALLATIONS THE RIGHT ... · TR 600 HD is a severe duty motor supply cable for use in applications that require tray cable ratings, flexibility,

20

S CABLES SPECIAL/HYBRID CABLES

WE DEVELOP AND PRODUCE CABLES AND WIRES

AS WELL AS SPECIAL SOLUTIONS PARTICULARLY ACCORDING TO YOUR REQUIREMENTS AND APPLICATIONS.

Here is a small sample of some of the challenges that Special Cables from SAB North America can help address:

n Hybrid Designs for multiple functions- In situations with space and budget constraints, a hybrid cable accommodates multiple functions like communications and control, fiber optics, power, pneumatics, and hydraulics.

n Harsh Environments- Because cables must endure inhospitable environments, standard cables can be customized with the right materials to resist threats such as temperature extremes from -50°C to 200°C, tears and abrasions, oils, solvents, and flames.

n Difficult applications- In many cases, cables must function reliably despite distinctive operating conditions such as high- speed data handling, unique motion and mechanical stresses in robotics and automated machines, reeling and pulley structures in hoists and transport systems, resistance to EMI and RFI in motors and drives as well as use with disinfectants and cleaning substances in medical and other sanitary environments.

n Industries- SAB North America customizes Special Cables for a diversity of industries such as industrial automation, renewable energy, transportation, medical, and entertainment and amusements.

Special cables and hybrid cables can help solve design problems or perform in challenging operating environments where standard cables may fall short. Customers can select from a large catalog of materials and jacket combinations, and SAB North America can assist customers in modifying or designing a completely new cable. Order minimums are as low as 1,500 feet, and we can test your unique product in our lab. No matter your application’s requirements, SAB North America Special Cables expand the possibilities of standard cables and address your design challenges.

Whatever the need may be, look to SAB North America for Special Cables that can, for example, help minimize maintenance costs and increase productivity, reduce downtime, and solve specific problems.

866-722-2974 • www.sabcable.com

Page 21: TRAY CABLES FOR INDUSTRIAL PLANT INSTALLATIONS THE RIGHT ... · TR 600 HD is a severe duty motor supply cable for use in applications that require tray cable ratings, flexibility,

21

S CABLES DESIGNED TO SPECIFICATION

Conductor Materials

n Bare copper n Tinned copper n Silver plated copper n Nickel plated copper n Nickel n Nickel pure n Compensating cable alloys

Conductor Sizes

n 0.14 mm2 - 300 mm2

(26 AWG to 500 MCM) n variety of stranding styles

Insulation and Jacketing Materials

n PVC (many varieties) n Polyethylene n Polypropylene n TPE n Fiberglass n Besilen®/Silicone n Pi foil n FEP, ETFE, PFA, PTFE n A zero halogen n Polyurethane

Conductor Count Ranges

n unshielded - up to 125 conductors n shielded - up to 100 conductors

Temperature Ranges (based on material) n Thermoplastic Elastomers -50°C up to +145°C

n Besilen®/Silicone -40°C up to +220°C

n FEP, ETFE, PFA, PTFE -90°C up to +260°C

n Halogen-free -50°C up to +220°C

n Fiberglass up to +600°C

Shielding and Braiding Materials

n Bare copper

n Tinned copper

n Galvanized steel

n Stainless steel

n Aluminium foil

n Fiberglass

n Aramid

Approvals n UL, CSA, CE, EAC, VDE, HAR, IEC, EN, ISO, DNV-GL, LR, ABS, RINA, RMRS, BSI

Order minimums are as low as 1,500 feet, and we can test your unique product in our lab. No matter your application’s requirements, SAB North America Special Cables expand the possibilities of standard cables and address your design challenges.

866-722-2974 • www.sabcable.com

Page 22: TRAY CABLES FOR INDUSTRIAL PLANT INSTALLATIONS THE RIGHT ... · TR 600 HD is a severe duty motor supply cable for use in applications that require tray cable ratings, flexibility,

22

CORD GRIP SECURING YOUR CABLE

Accessories & Fittings

Enlargers Reducers Multi-Hole BushingDummy Plugs

Vent Gland & Plugs Locknuts

CG 100 Polyamide Cord Grips Dome cap, black or gray available in NPT, PG, or metric thread

Liquid tight seal, fast and easy installation, wide clamping range, multi-purpose applications, easy handling.

CG 200 Polyamide Cord Grips Flex cap, black or gray available in NPT, PG, or metric thread

Strain relief gland offers maximum protection against conductor fatigue caused by flexing cables

CG 300 Nickel Plated Brass Cord Grips Available in NPT, PG, or metric thread

Impact resistant, suitable for industrial applications, water tight, corrosion resistant.

CG 350 SS303 or SS316 Stainless Steel Cord Grips Available in NPT, PG, or metric thread

Impact resistant, suitable for industrial applications, water tight, corrosion resistant.

EMC-2 Cord Grips Nickel plated brass EMC cable gland available in NPT, PG, or metric thread

EMC-2 is a nickel plated brass strain relief with integral grounding springs in the gland. Features: n One Direction Installation n Affordable n Nickel Plated Brass with Tinned Copper Springs

EMC-4 Cord Grips Nickel plated brass, EMC cable gland, vibration proof, available in NPT, PG, or metric thread

EMC-4 is a nickel plated brass strain relief with integral grounding springs in the gland that will allow the cable to move without damage to the shield. Features: n Bi-directional Installation n Great Anti-Vibration Mechanisms n Nickel Plated Brass with Tinned Copper Springs

866-722-2974 • www.sabcable.com

Page 23: TRAY CABLES FOR INDUSTRIAL PLANT INSTALLATIONS THE RIGHT ... · TR 600 HD is a severe duty motor supply cable for use in applications that require tray cable ratings, flexibility,

23

ADDITIONAL PRODUCTS TEMPERATURE MEASUREMENT

SAB North America has expertise in thermocouples, resistance thermometers and the cabling you need to build an optimal assembly. We’re well-positioned to answer cabling questions that pertain to your temperature measurement needs.

CABLE HARNESSING

866-722-2974 • www.sabcable.com

WE SUPPLY HARNESSED CABLES AND WIRES

FROM A SINGLE SOURCE.

n Helix cables

n Harnessed cables according to customers’ specification

n Cable harnesses

n Harnessed motor and transmission cables for Siemens and Indramat drives

n Harnessed track cable

n Various combinations of connector types and terminals

n Many application of various materials and sheath materials

n Complete solutions

n High quality standard by continuous quality control

n Protecting armatures and gauge slides

n Mineral insulated thermocouples

n Mineral insulated resistance thermometers

n Temperature measurement in plastics processing industry/Hot runner process

n Temperature measurement in test vehicles

n Probe with stainless steel sleeve

n Compensating and extension cables

n Accessories

WITH US YOU GET TEMPERATURE MEASUREMENT

AND ACCESSORIES FOR A WIDE VARIETY OF REQUIREMENTS AND INDUSTRIES.

Page 24: TRAY CABLES FOR INDUSTRIAL PLANT INSTALLATIONS THE RIGHT ... · TR 600 HD is a severe duty motor supply cable for use in applications that require tray cable ratings, flexibility,

344 Kaplan Drive Fairfield, NJ 07004

Toll Free: 866­722­2974 www.sabcable.com [email protected]

April 2020