transfer accuracy - why micro motion1.4 3” 4” 6” 8” 10” 12” 16” 150 600 860 1400 2285...

2
0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 2” 3.8 3.7 3.5 3.4 2.4 1.8 1.6 1.4 3” 4” 6” 8” 10” 12” 16” 150 600 860 1400 2285 2800 7200 12500 DN50 DN80 DN100 DN150 DN200 DN250 DN300 DN400 CFM200 CFM300 CMF300 CMF350 CMF400 CMF400 CMFHC2 CMFHC3 PD Meter Size Flow Rate bbl/h DN Size Coriolis Meter Model ADVANTAGES OF MICRO MOTION CORIOLIS TECHNOLOGY CORIOLIS CUSTODY TRANSFER ACCURACY WITHOUT THE MAINTENANCE METER FACTOR STABILITY - PD VS. CORIOLIS* PD OVERHAULS REQUIRED TO ACHIEVE PAYBACK WITH CORIOLIS REPLACEMENT METER METER REPLACED METER FACTOR MONTHS # OF FAILURES/REPAIRS PD METER CORIOLIS METER Unmatched flow and density measurement performance for ultimate process control ± 0.1% (± 0.05% option) mass flow accuracy ± 0.1% volume flow accuracy 0.0005 g/cm 3 density accuracy 20:1 turndown in custody transfer applications Bi-directional flow for process flexibility No moving parts, eliminating maintenance and mechanical slippage errors Immune to environmental and fluid effects Cannot be damaged by pulsating flows, flow surges, slug flow and entrained gas Continuous, full stream density measurement for net volume calculations and API confirmation High repeatability for efficient field proving Superior measurement confidence with Smart Meter Verification (SMV), an online diagnostic tool that verifies meter health Fast response/refresh rates for reliable proving EASY TO REPLACE Direct replacement with most 10” – 12” positive displacement (PD) meters Simple retrofit parts and design available 1 0 1.035 1.015 1.025 1.005 1.03 1.01 1.02 1 0.995 5 11 3 9 7 13 2 6 12 4 10 8 14 *Proving data taken over a 14-month period at the same truck loading facility American Petroleum Institute (API) Manual of Petroleum Measurement Standards Chapter 5.6 - Measurement of Liquid Hydrocarbons by Coriolis Meters ANSI/API MPMS 5.6 - 2013 COMPLIANCE WITH INDUSTRY STANDARDS

Upload: others

Post on 30-Jan-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: TRANSFER ACCURACY - Why Micro Motion1.4 3” 4” 6” 8” 10” 12” 16” 150 600 860 1400 2285 2800 7200 12500 dn50 dn80 dn100 dn150 dn200 dn250 dn300 dn400 cfm200 cfm300 cmf300

0.5

1.0

1.5

2.0

2.5

3.03.5

4.0

2”

3.8 3.7 3.5 3.4

2.4

1.81.6

1.4

3” 4” 6” 8” 10” 12” 16”150 600 860 1400 2285 2800 7200 12500

DN50 DN80 DN100 DN150 DN200 DN250 DN300 DN400

CFM200 CFM300 CMF300 CMF350 CMF400 CMF400 CMFHC2 CMFHC3

PD Meter SizeFlow Rate bbl/h

DN Size

Coriolis Meter Model

ADVANTAGES OF MICRO MOTION CORIOLIS TECHNOLOGY

CORIOLIS CUSTODY TRANSFER ACCURACYWITHOUT THE MAINTENANCE

METER FACTOR STABILITY - PD VS. CORIOLIS*

PD OVERHAULS REQUIRED TO ACHIEVE PAYBACK WITH CORIOLIS REPLACEMENT METER

METER REPLACED

ME

TER

FA

CTO

R

MONTHS

# O

F

FA

ILU

RE

S/R

EPA

IRS

PD METER

CORIOLIS METER

• Unmatched flow and density measurement performance for ultimate process control

• ± 0.1% (± 0.05% option) mass flow accuracy

• ± 0.1% volume flow accuracy

• 0.0005 g/cm3 density accuracy

• 20:1 turndown in custody transfer applications

• Bi-directional flow for process flexibility

• No moving parts, eliminating maintenance and mechanical slippage errors

• Immune to environmental and fluid effects

• Cannot be damaged by pulsating flows, flow surges, slug flow and entrained gas

• Continuous, full stream density measurement for net volume calculations and API confirmation

• High repeatability for efficient field proving

• Superior measurement confidence with Smart Meter Verification (SMV), an online diagnostic tool that verifies meter health

• Fast response/refresh rates for reliable proving

EASY TO REPLACE • Direct replacement with most 10” – 12”

positive displacement (PD) meters

• Simple retrofit parts and design available

10

1.035

1.015

1.025

1.005

1.03

1.01

1.02

1

0.9955 113 97 132 6 124 108 14

*Proving data taken over a 14-month period at the same truck loading facility

• American Petroleum Institute (API)

• Manual of Petroleum Measurement Standards

• Chapter 5.6 - Measurement of Liquid Hydrocarbons by Coriolis Meters

• ANSI/API MPMS 5.6 - 2013

COMPLIANCE WITH INDUSTRY STANDARDS

Page 2: TRANSFER ACCURACY - Why Micro Motion1.4 3” 4” 6” 8” 10” 12” 16” 150 600 860 1400 2285 2800 7200 12500 dn50 dn80 dn100 dn150 dn200 dn250 dn300 dn400 cfm200 cfm300 cmf300

©2014 Micro Motion, Inc. All rights reserved. For more information, visit www.MicroMotion.com

Typical applications: LACT, Truck Mounted, Pipeline, Loading, Cavern Storage

INDUSTRY ACCEPTED• Installed globally in a range of complex

industrial applications

• Meets or exceeds API standards for crude oil and hydrocarbon product

WE MAKE IT EASY:Micro Motion has the products and industry expertise to support

your application from the design to the field.

EDUCATIONAL SERVICES • FLOW AUDITS • SYSTEM DESIGN • COMMISSIONING • CALIBRATING SERVICES

Coriolis vs. PD Flowmeter Components

Process ConnectionFlange

Flow Tube

Resistance Thermal Device (RTD)

Pickoff Coils

Case

Drive Coil