trane residential an.. - hvac.amickracing residential and light... · 2007-01-16trane residential...

366

Click here to load reader

Upload: ngominh

Post on 28-Apr-2018

1.501 views

Category:

Documents


308 download

TRANSCRIPT

Page 1: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing
Page 2: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

Effective 1/1/06

Introduction

This is your Trane Residential and Light Commercial Products Handbook,published in January, 2006.

This handbook was created to provide one easy-to-use source forgeneralized information pertaining to 1 ton through 25 ton Trane products.However, it should not be used to replace the comprehensive Trane ProductData Catalogs. Product Data Catalogs contain critical and pertinent data notfound in this handbook.

This handbook does not contain data such as ARI system ratings,performance tables, etc… If you require this information, you should alwaysrefer to the most current Trane Product Data Catalog.

Effective immediately, this handbook will be published semi-annually.Tentative print dates are set for July, 2006 and again in January, 2007. Wewill attempt to maintain a ready supply of these printed catalogs in ourdistribution warehouse, and you can reorder as often as you wish. ThePublication Number is shown on the back cover of this handbook. Reprintsmade between January 2006 and June 2006 will not include any new/revisedinformation. This information will only become available in the July 2006edition.

This handbook will, however, be updated quarterly on TraneNet™ andComfortSite™. If you do not have access, please consult with your Tranedistributor. This electronic information will subsequently be the most currentinformation available.

If you find information that needs to be corrected/updated or added, pleasesend your recommendations directly to:

Kaye Berry / Jeff MondrikResidential Product SupportTrane Residential SystemsTyler, Texas [email protected] / [email protected](903) 581-9199 or (903) 509-7222 (Fax #s)

Thank you for the opportunity to provide you with an updated Trane handbook.

Page 3: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

Effective 1/1/06TOC-1For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Contents

This publication is for general referenceinformation only and is not intended forsystems equipment / combination selections.

For complete equipment / combinationselections and installation instructions,please refer to Product Data and InstallersGuides.

Products listed in this book are not alwayscarried in factory/distributor inventory, nor areall products available through all distributionchannels. Consult your Distributor for avail-ability and shipping information.

Since Trane has a policy of continuous productimprovement, it reserves the right to changedesign and specification without notice.

The Manufacturer’s Limited Warranties oncurrent residential split condensing units andsystems installed on or after 10/01/2001where product is manufactured after January1, 2000. The new Manufacturer’s LimitedWarranties are not retroactive to installationsprior to 10/01/2001 or units manufacturedbefore 2000 (see The Limited WarrantyGuidelines for more information, 26-1000-14).

Model Nomenclature ................................................................................................. TOC-4Split System Cooling

• Single Phase, 1½ through 5 Tons (2TTZ, 2TTX, 4TTX) ...................................... SC-1• Single Phase, 1½ through 5 Tons (2TTR, 4TTR) ................................................. SC-3• Single Phase, 1 through 5 Tons (2TTB, TTB) ...................................................... SC-7• Three Phase, 2½ through 6 Tons (2TTA) ............................................................ SC-9• Three Phase, 7½ through 20 Tons (TTA) .......................................................... SC-11• ReliaTel™ Controls Protection/Operation Timings and Features ...................... SC-17• ReliaTel™ Micro Control Operation with a Thermostat ...................................... SC-18

Split System Heat Pumps• Single Phase, 1½ through 5 Tons (2TWZ, 4TWX, 2TWX) ................................... SH-1• Single Phase, 1½ through 5 Tons (4TWR, 2TWR) .............................................. SH-3• Single Phase, 1½ through 5 Tons (2TWB) ........................................................... SH-7• Three Phase, 2½ through 6 Tons (2TWA) ........................................................... SH-9• Three Phase, 7½ through 20 Tons (TWA) ......................................................... SH-11

Air Handlers/Heaters• Convertibility Chart ............................................................................................... AH-1• Air-Tite™ Features and Benefits .......................................................................... AH-2• Single Phase, 1½ through 5 Tons (TWE-E, 4TEE) .............................................. AH-3• Single Phase, 1½ through 5 Tons (2TEH) ........................................................... AH-4• Single Phase, 1½ through 5 Tons (2/4TEC) ........................................................ AH-5• Single Phase, 1½ through 4 Tons (2TGB) ........................................................... AH-6• Single Phase, 1½ through 2½ Tons (2TFB, 2/4TFE) ........................................... AH-7• Heaters for Split System and Convertible ............................................................ AH-8• Single Phase, 1½ through 5 Tons (TWE-P, 2TEP, 4TEP) ................................. AH-11• Single Phase, 1½ through 5 Tons (TWE-C) ....................................................... AH-12• Single Phase, 1½ through 5 Tons (TWG) .......................................................... AH-13• Single Phase, 1½ through 3 Tons (2TFB, 2TFE) ............................................... AH-14• Single Phase 5-10 Tons, Three Phase 5-20 Tons (TWE) .................................. AH-15

Furnaces/Coils• XV, XL, XT, XR, XB 90 Airflow Directions .......................................................... FUR-1• XV, XL 90 Convertible (TUY, TDY, TUX, TDX) .................................................. FUR-2• XT, XR 90 Convertible (TUX, TDX) .................................................................... FUR-3• XR, XB 90 Convertible (TUX, TDX, TUC, TDC) ................................................. FUR-4• XV, XL, XT, XR, XB 80 Airflow Directions .......................................................... FUR-7• XV, XL 80 Convertible (TUD, TDD) .................................................................... FUR-8• XT, XR 80 Convertible (TUD, TDD) ................................................................... FUR-9• XR, XB 80 Convertible (TUD, TDD, TUE, TDE) ............................................... FUR-10• XV80 Variable Speed High Efficiency Oil Furnaces (THV, TLF, TLR, TDF) .... FUR-13• XP80 High Efficiency Oil Furnaces (THV, TLF, TLR, TDF) ............................. FUR-14• Quick Reference Charts ................................................................................... FUR-15• Split System Cased Heat Pump and Cooling Coils (2/4TXC, 2/4TXF) ............ FUR-19• Split System Cased Heat Pump and Cooling Coils (2/4TXC, 2CXC) ............... FUR-20• Split System Cased/Uncased Cooling Only Coils (4CXC, 2/4CXA) ................. FUR-21• Split System Cased/Uncased Heat Pump and Cooling Coils

(TXC, RXC, RXA, TXE) ................................................................................. FUR-22• Split System Cased Heat Pump and Cooling Coils (TXC, RXH, TXH) .............. FUR-23• Split System Cased/Uncased Heat Pump and Cooling Coils (TXA, CCB, CUB) FUR-24• Coil Enclosures ................................................................................................. FUR-25• Furnace/Coils Matrix ......................................................................................... FUR-26

Indoor Air Quality• TRANE CleanEffects™ Air Cleaner and Upgrade Kits (TFD) .......................... IDAQ-1• Perfect Fit™ Air Cleaner (TFE) ........................................................................ IDAQ-2• Perfect Fit™ Air Cleaner (TFM, TFP) ............................................................... IDAQ-3• Perfect Fit ™ Filter Accessories ....................................................................... IDAQ-4• Humidifiers Fan Powered and Bypass ............................................................ IDAQ-7• FreshEffects™ Energy Recovery Ventilator (TERV) ..................................... IDAQ-10

Package Cooling• Convertible, 1½ through 5 Tons (4TCX) .............................................................. PC-1• Convertible, 1½ through 5 Tons (4TCC) .............................................................. PC-6

© 2006 American Standard All Rights Reserved

Page 4: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

TOC-2For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Effective 1/1/06

Contents

This publication is for general referenceinformation only and is not intended forsystems equipment / combinationselections.

Package Cooling (continued)• Convertible, 2 through 5 Tons (TCY, TCX) ........................................................ PC-13• Convertible, 1½ through 5 Tons (TCP, TCC) ..................................................... PC-14• Convertible, 1½ through 5 Tons (TCY, TCX, TCP, TCC) .................................. PC-15• Electric Heat, 2 through 4 Tons (TCK) ............................................................... PC-19• Manufactured Housing, 2½ through 4 Tons (TCM) ............................................ PC-21• Over/Under, 2 through 5 Tons (TCH) ................................................................. PC-22• Precedent™ Convertible, 3-10 Tons Features ................................................... PC-24• Precedent™ Convertible, 3-10 Tons (TSC) ....................................................... PC-25• Precedent™ Convertible, 3-10 Tons (THC) ....................................................... PC-27• Light Commercial New Model Quick Reference ................................................. PC-33• ReliaTel™ Controls for Precedent™ 13 SEER and Voyager™ ......................... PC-35• Micro Control for Precedent™, Precedent™ 13 SEER and Voyager™ ............. PC-36• Precedent™ Convertible, 3-5 Tons 13 SEER R-22 (THC) ................................. PC-38• Voyager™ with ReliaTel™ Controls, 12½ through 25 Tons (TCD) .................... PC-43• Voyager™ with ReliaTel™ Controls, 12½ through 25 Tons (TCH) .................... PC-44

Package Heat Pump• Convertible, 1½ through 5 Tons (2/4WCX) .......................................................... PH-1• Convertible, 1½ through 5 Tons (2/4WCC) .......................................................... PH-6• Convertible, 2 through 5 Tons (WCZ, WCY, WCX) ........................................... PH-13• Convertible, 1½ through 5 Tons (WCP, WCC) ................................................... PH-14• Convertible, 1½ through 5 Tons (WCZ, WCY, WCX, WCP, WCC) ................... PH-15• Dual Fuel with Auxiliary Gas Heat (DCY) ........................................................... PH-16• Electric Heat, 2 through 3½ Tons (WCK) ........................................................... PH-20• Over/Under 2 through 5 Tons (WCH) ................................................................. PH-21• Manufactured Housing, 2½ through 3½ Tons (WCM) ....................................... PH-23• Precedent™ Convertible, 3-10 Tons Features ................................................... PH-24• Precedent™ Convertible, 3-10 Tons (WSC) ...................................................... PH-25• Light Commercial New Model Quick Reference ................................................. PH-29• Voyager™ with ReliaTel™ Controls, 12½ through 20 Tons (WCD, WCH) ........ PH-30

Package Gas/Electric• Convertible, 2 through 5 Tons (2YCX) ................................................................. PG-1• Convertible, 1½ through 5 Tons (4YCX) .............................................................. PG-2• Convertible, 2 through 5 Tons (2YCC) ................................................................. PG-7• Convertible, 1½ through 5 Tons (4YCC) .............................................................. PG-8• Convertible, 1½ through 5 Tons (YCZ, YCY, YCX) ............................................ PG-14• Convertible, 2 through 5 Tons (YCX, YCP) ........................................................ PG-15• Convertible, 1½ through 5 Tons (YCC) .............................................................. PG-16• Convertible, 2 through 5 Tons (YCZ, YCY, YCX) ............................................... PG-19• Convertible, 1½ through 5 Tons (YCP, YCC) ..................................................... PG-20• Precedent™ Convertible, 3-10 Tons Features ................................................... PG-21• Precedent™ Convertible, 3-10 Tons (YSC) ....................................................... PG-22• Precedent™ Convertible, 3-10 Tons (YHC) ....................................................... PG-28• Light Commercial New Model Quick Reference ................................................. PG-33• Precedent™ Convertible, 3-5 Tons 13 SEER R-22 Features ............................ PG-37• Precedent™ Convertible, 3-5 Tons 13 SEER R-22 (YHC) ................................ PG-38• Voyager™ with ReliaTel™ Controls 12½ through 15 Tons (YCD) ..................... PG-43• Voyager™ with ReliaTel™ Controls 17½ through 25 Tons (YCD) ..................... PG-44• Voyager™ with ReliaTel™ Controls 12½ through 15 Tons (YCH) ..................... PG-45• Voyager™ with ReliaTel™ Controls 17½ through 25 Tons (YCH) ..................... PG-46

Factory Installed Options• Voyager™ Commercial Packaged Units 12½ through 25 Tons ..................... FIOPS-1• Factory Installed Options Accessories ........................................................... FIOPS-2• Factory Installed Options Matrix Pages ........................................................ FIOPS-10

Comfort Controls/Zone Sensors• Comfort Control Definitions ............................................................................. CCZO-1• Programmable 7 Day ....................................................................................... CCZO-2• Programmable 5/2 Day .................................................................................... CCZO-4• Non-Programmable ......................................................................................... CCZO-5• Remote Sensors .............................................................................................. CCZO-7

Page 5: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

Effective 1/1/06TOC-3For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Contents

Comfort Controls/Zone Sensors (continued)• Humidity Control .............................................................................................. CCZO-8• Relay Hook-Up ................................................................................................ CCZO-8• Indoor Fan Delay Relay Kit ............................................................................. CCZO-9• Outdoor Thermostat Kit ................................................................................... CCZO-9• Cooling Only and Heating Only ..................................................................... CCZO-10• Single Stage .................................................................................................. CCZO-11• Multiple Stage ................................................................................................ CCZO-12• Heat Pump ..................................................................................................... CCZO-13• Zone .............................................................................................................. CCZO-14• ComfortLink™ System................................................................................... CCZO-15• Integrated Zone™ System Assembly and Accessories ................................ CCZO-15• Sensors for ComfortLink™ ............................................................................ CCZO-16• Integrated Zone™ System Dampers ............................................................. CCZO-17• Zone Sensor Unit Installation ........................................................................ CCZO-18• Micro Controls Zone Sensors ........................................................................ CCZO-19• Electronic Programmable Zone Sensors for ReliaTel™ Units ...................... CCZO-19• Electronic Zone Sensors for ReliaTel™ Units ............................................... CCZO-20• Integrated Comfort™ Systems Sensors for ReliaTel™ Units ....................... CCZO-21

Ductless Mini-Splits• Ductless Air Conditioners (MCW) ...................................................................... MINI-1• Ductless Outdoor Units (TTK) ........................................................................... MINI-2

Packaged Terminals/Unit Heaters• Packaged Terminal Air Conditioners and Heat Pumps ............................. PTAC/UH-1• Indoor Gas Heating Products Description ................................................. PTAC/UH-4• Indoor Units ............................................................................................... PTAC/UH-6• Model S – Horizontal Units ...................................................................... PTAC/UH-18• Model P – Vertical Units .......................................................................... PTAC/UH-26• Electric Unit – Voltage Control ................................................................. PTAC/UH-31• Electric Unit – Control Options ................................................................ PTAC/UH-33• Electric Unit, Hose Down Corrosion Resistant ........................................ PTAC/UH-36• Electric Unit, UHXA ................................................................................. PTAC/UH-38• Electric Ceiling Mounted Unit .................................................................. PTAC/UH-40• Electric Wall Mounted Units ..................................................................... PTAC/UH-42• Electric Wall Fin ....................................................................................... PTAC/UH-46

Extended Warranties• Labor Options ...................................................................................................... WA-1• Standard Servicer Guidelines .............................................................................. WA-2• Expanded Servicer Guidelines ............................................................................ WA-3• Optional Extended Warranty Benefits ................................................................. WA-4

Accessories/Information• Roof Curbs (BAYCURB050A, BAYCURB051A) ............................................. AC/IN-1• Roof Curb Adaptors (BAYADAP050A) ............................................................ AC/IN-2• Roof Curb Adaptors (BAYADAP051A) ............................................................ AC/IN-3• Roof Curb Adaptors (BAYADAP052A) ............................................................ AC/IN-4• Roof Curb Adaptors (BAYADAP053A) ............................................................ AC/IN-5• Roof Curb Adaptors (BAYADAP054A) ............................................................ AC/IN-6• Impack™ Roof Curbs (BAYCURB030A, BAYCURB038A) ............................. AC/IN-7• Impack™ Roof Curbs (BAYCURB033A, BAYCURB034A) ............................. AC/IN-8• Thermal Expansion Valves .............................................................................. AC/IN-9• Refrigerant Line Sets ..................................................................................... AC/IN-11• Base Pan Sizes ............................................................................................. AC/IN-12• Equipment Date Identification ........................................................................ AC/IN-15• Refrigerant ..................................................................................................... AC/IN-16• Split System Refrigerant Piping, 7½-20 Ton (HCFC-22) ............................... AC/IN-20• Branch Circuit Wire Sizing Table/Heater De-Rating Chart ............................ AC/IN-21• Basic Air Conditioning Formulas ................................................................... AC/IN-22• Low Ambient Accessories, Cooling Models ................................................... AC/IN-23• Low Ambient Accessories, Heat Pump Models ............................................. AC/IN-24• Wind Shields .................................................................................................. AC/IN-25

Page 6: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

TOC-4For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Effective 1/1/06

Air Handler -Residential

ModelNomenclature

Outdoor Units

Accessories

Commercial Condensing UnitsCooling and Heat Pump

Page 7: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

Effective 1/1/06TOC-5For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

ModelNomenclature

Air Handler -Residential

Air Handler -Commercial

Air Handler/Electric FurnaceHeaters

Furnaces15 - Digit

Page 8: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

TOC-6For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Effective 1/1/06

Oil Furnaces

Oil FurnaceAccessories

ModelNomenclature

Gas FurnacesHeat Pump/Cooling Coils

Page 9: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

Effective 1/1/06TOC-7For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

ModelNomenclature

Perfect Fit™Air Cleaner

Perfect Fit™ FilterAccessories

TRANECleanEffects™Whole HouseAir Cleaner

Furnace Coils

TXV Kits

Page 10: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

TOC-8For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Effective 1/1/06

ModelNomenclature

Humidifiers

HumidifierAccessories

HumidifierControls

EnergyRecoveryVentilator(ERV)

Page 11: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

Effective 1/1/06TOC-9For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Package Units15 - Digit

Package Units

ModelNomenclature

Page 12: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

TOC-10For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Effective 1/1/06

ModelNomenclature

Precedent™Units

Page 13: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

Effective 1/1/06TOC-11For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

ModelNomenclature

Precedent™13 SEER Units

Page 14: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

TOC-12For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Effective 1/1/06

Integrated Zone™System

ModelNomenclature

DuctlessOutdoor Units

DuctlessAir Conditioners

ComfortControls

Page 15: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

Effective 1/1/06TOC-13For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

ModelNomenclature

PackagedTerminals

Indoor GasHeating Units

Page 16: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

TOC-14For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Effective 1/1/06

Model SUnit Heater

ModelNomenclature

HorizontalBlower Assembly

Page 17: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

Effective 1/1/06TOC-15For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

ModelNomenclature

Model PUnit Heater

Electric HeatersModel UHEC

Electric WallMountedUnitHeatersModel UHWA

Page 18: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

TOC-16For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Effective 1/1/06

Electric CeilingMounted HeatersModel UHCA

Electric ExplosionProof Unit HeatersModel UHXA

ModelNomenclature

Electric Hose DownUnit HeaterModel UHRA

ElectricArchitecturalWall HeatersModel UHAA

Page 19: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

SC-1For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Effective 1/1/06

Split System CoolingSingle Phase – 1½ through 5 Tons

Table SC-1-A — XL19i Split System Cooling — Single PhaseNom. Cap. Uncrated Shipping Line Size

Model Power Cooling Metering Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Device H W D (lbs.) Rating MCA* Fuse* Gas Liq.

2TTZ9030B1000A 200-230/1/60 30,000 TXV-NB 50 37 34 439 72 18 30 7/8 3/82TTZ9036B1000A 200-230/1/60 36,000 TXV-NB 50 37 34 436 74 22 35 7/8 3/82TTZ9048B1000A 200-230/1/60 48,000 TXV-NB 50 37 34 444 74 25 40 11/8 3/82TTZ9060B1000A 200-230/1/60 60,000 TXV-NB 50 37 34 448 73 37 60 11/8 3/8

Note: Because of limited capabilities, please refer to product data for approved combinations.

Table SC-1-B — XL16i Split System Cooling — Single PhaseNom. Cap. Uncrated Shipping Line Size

Model Power Cooling Metering Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Device H W D (lbs.) Rating MCA* Fuse* Gas Liq.

4TTX6024B1000A 230/1/60 24,000 TXV-NB 44 33 30 254 73 12 20 5/8 5/16

4TTX6036B1000A 230/1/60 36,000 TXV-NB 42 37 34 288 72 24 40 3/4 3/84TTX6048B1000A 230/1/60 48,000 TXV-NB 50 37 34 312 74 29 50 7/8 3/84TTX6060B1000A 230/1/60 60,000 TXV-NB 50 37 34 356 74 35 60 7/8 3/8

Table SC-1-C — XL15i Split System Cooling — Single PhaseNom. Cap. Required Uncrated Shipping Line Size

Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.

2TTX5024A1000A 208/230/1/60 24,000 TXV-NB 46 37 34 283 72 14 20 3/4 5/16

2TTX5030A1000A 208/230/1/60 30,000 TXV-NB 46 37 34 284 74 16 25 3/4 5/16

2TTX5036A1000A 208/230/1/60 36,000 TXV-NB 50 37 34 300 72 18 30 7/8 3/82TTX5042A1000A 208/230/1/60 42,000 TXV-NB 50 37 34 307 73 23 35 7/8 3/82TTX5048A1000A 208/230/1/60 48,000 TXV-NB 50 37 34 337 72 26 40 11/8 3/8

Table SC-1-D — XL14i Split System Cooling — Single PhaseNom. Cap. Required Uncrated Shipping Line Size

Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.

2TTX4018B1000A 200-230/1/60 18,000 TXV-NB 40 33 30 220 73 10 15 5/8 1/42TTX4024B1000A 200-230/1/60 24,000 TXV-NB 40 33 30 236 73 11 15 3/4 5/16

2TTX4030B1000A 208-230/1/60 30,000 TXV-NB 40 33 30 244 74 18 30 3/4 5/16

2TTX4036B1000A 208-230/1/60 36,000 TXV-NB 44 33 30 248 72 20 30 7/8 3/82TTX4042B1000A 208-230/1/60 42,000 TXV-NB 46 37 34 289 75 24 40 7/8 3/82TTX4048B1000A 208-230/1/60 48,000 TXV-NB 50 37 34 306 75 28 45 11/8 3/82TTX4060B1000A 208-230/1/60 60,000 TXV-NB 50 37 34 354 75 34 50 11/8 3/8

Table SC-1-E — XL14i Split System Cooling — Single PhaseNom. Cap. Required Uncrated Shipping Line Size

Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.

4TTX4018B1000A 200-230/1/60 18,000 TXV-NB 40 33 30 236 74 10 15 1/2 1/44TTX4024B1000A 200-230/1/60 24,000 TXV-NB 40 33 30 239 74 13 20 5/8 5/16

4TTX4030B1000A 208-230/1/60 30,000 TXV-NB 40 33 30 242 71 20 30 3/4 5/16

4TTX4036B1000A 208-230/1/60 36,000 TXV-NB 44 33 30 255 71 21 35 3/4 3/84TTX4042B1000A 208-230/1/60 42,000 TXV-NB 46 37 34 297 74 25 40 3/4 3/84TTX4048B1000A 208-230/1/60 48,000 TXV-NB 50 37 34 310 74 27 45 7/8 3/84TTX4060C1000A 208-230/1/60 60,000 TXV-NB 50 37 34 360 74 35 60 7/8 3/8

* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.** Rated in accordance with ARI Standard 270, section 5.3.6.

XL19i

XL14i

XL14i

XL16i

XL15i

Page 20: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

SC-2For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Effective 1/1/06

Split System CoolingSingle Phase – 1½ through 5 Tons

XL19i XL16i XL15i XL14i XL 14iTable SC-2-A — Features (2TTZ9) (4TTX6) (2TTX5) (2TTX4) (4TTX4)• SEER’s up to .......................................................................................................... 19.50 17.15 16.25 15.00 15.00• Climatuff™ compressor ........................................................................................ 2 1 - staged ✔ ✔ ✔• Comfort”R”™ mode approved ............................................................................. ✔ ✔ ✔ ✔ ✔• DuraTuff™ base, fast complete drain, weatherproof ............................................. ✔ ✔ ✔ ✔ ✔

• Quick-Sess™ cabinet, service access & .............................................................. ✔ ✔ ✔ ✔ ✔ refrigerant connections with full coil protection

• Spine Fin™ coil ..................................................................................................... ✔ ✔ ✔ ✔ ✔

• Weatherguard™ II top .......................................................................................... ✔ ✔ ✔ ✔ ✔• Compressor sound enclosure ................................................................................ ✔ ✔ ✔ ✔ ✔• Compressor sump heat - factory installed .............................................................. 2½-5 5 2-4 1½-2 & 3½-5 1½-2• Factory supplied charge ......................................................................................... R-22 R-410A R-22 R-22 R-410A• Glossy corrosion resistant finish ............................................................................ ✔ ✔ ✔ ✔ ✔• High pressure switch .............................................................................................. — ✔ — — ✔

• Internal high / low pressure & temperature protection ............................................ ✔ ✔ ✔ ✔ ✔• Liquid line filter drier - factory installed ................................................................... ✔ ✔ ✔ ✔ ✔• Quick start kit-factory installed ............................................................................... 2½-5 5 — 1½-2 & 5 1½-2 & 5• Seacoast shield - factory installed .......................................................................... ✔ ✔ ✔ ✔ ✔• Tarpaulin gray cabinet ............................................................................................ ✔ ✔ ✔ ✔ ✔• 10-year limited warranty on compressor, ............................................................... ✔ ✔ ✔ ✔ ✔

outdoor coil & parts (Residential)• Extended warranties available ............................................................................ ✔ ✔ ✔ ✔ ✔

Table SC-2-B — Optional AccessoriesAY28X079 ..................... Evaporator defrost control kit ............................................. ✔ ✔ ✔ ✔ ✔BAYCCHT301 ............... Crank Case Heater Kit (Scroll Compressors) ................... — 2-4 — 2½-3 2½-5BAYECMT001 ............... Extreme Condition Mounting Kit ........................................ ✔ ✔ ✔ ✔ ✔BAYISLT101 .................. Rubber Isolators ................................................................. ✔ ✔ ✔ ✔ ✔BAYKSKT260 ............... Quick start kit (21/2 - 4 ton) (Scroll Compressors) ............. — 2-4 2-4 2½-4 2½-4BAYLEGS002 ............... Snow Legs - Base and Cap 6" High (Black) ...................... ✔ ✔ ✔ ✔ ✔BAYLEGS003 ............... 4" Extension (Black) ........................................................... ✔ ✔ ✔ ✔ ✔TAYASCT501A12 ...... Anti-Short Cycle Timer ....................................................... ✔ ✔ ✔ ✔ ✔

Comfort Controls — See Comfort Controls/Zone Sensors Section1 Not for use with programmable thermostats.2 Activated on Power Off.

Page 21: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

SC-3For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Effective 1/1/06

Table SC-3-A — XR14 Split System Cooling — Single PhaseNom. Cap. Required Uncrated Shipping Line Size

Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.

2TTR4018A1000A 200-230/1/60 18,000 TXV-NB 33 33 30 206 76 10 15 5/8 1/42TTR4024A1000A 200-230/1/60 24,000 TXV-NB 33 33 30 225 76 11 15 3/4 5/16

2TTR4030A1000A 208-230/1/60 30,000 TXV-NB 37 33 30 232 75 18 30 3/4 5/16

2TTR4036A1000A 208-230/1/60 36,000 TXV-NB 37 33 30 236 76 20 30 7/8 3/82TTR4042A1000A 208-230/1/60 42,000 TXV-NB 37 37 30 269 78 24 40 7/8 3/82TTR4048A1000A 208-230/1/60 48,000 TXV-NB 41 37 34 285 77 28 45 1 1/8 3/82TTR4060A1000A 208-230/1/60 60,000 TXV-NB 41 37 34 336 79 34 50 1 1/8 3/8

Table SC-3-B — XR14 Split System Cooling — Single PhaseNom. Cap. Required Uncrated Shipping Line Size

Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.

4TTR4018A1000A 200-230/1/60 18,000 TXV-NB 33 33 30 222 75 10 15 1/2 1/44TTR4024A1000A 200-230/1/60 24,000 TXV-NB 33 33 30 225 76 13 20 5/8 5/16

4TTR4030A1000A 208-230/1/60 30,000 TXV-NB 33 33 30 228 74 20 30 3/4 5/16

4TTR4036A1000A 208-230/1/60 36,000 TXV-NB 37 33 30 240 74 21 35 3/4 3/84TTR4042A1000A 208-230/1/60 42,000 TXV-NB 37 37 34 273 76 25 40 3/4 3/84TTR4048A1000A 208-230/1/60 48,000 TXV-NB 41 37 34 285 76 27 45 7/8 3/84TTR4060B1000A 208-230/1/60 60,000 TXV-NB 41 37 34 335 77 35 60 7/8 3/8

Table SC-3-C — XR13 Split System Cooling — Single PhaseNom. Cap. Required Uncrated Shipping Line Size

Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.

2TTR3018A1000A 200-230/1/60 18,000 TXV-NB 26 29 26 180 74 8 15 5/8 1/42TTR3024A1000A 200-230/1/60 24,000 TXV-NB 33 29 26 195 76 12 20 3/4 5/16

2TTR3030A1000A 200-230/1/60 30,000 TXV-NB 33 33 30 226 74 13 20 3/4 5/16

2TTR3036A1000A 208-230/1/60 36,000 TXV-NB 33 33 30 221 75 18 30 7/8 3/82TTR3042A1000A 200-230/1/60 42,000 TXV-NB 33 37 34 284 77 21 35 7/8 3/82TTR3048A1000A 200-230/1/60 48,000 TXV-NB 41 37 34 309 76 25 40 1 1/8 3/82TTR3060A1000A 208-230/1/60 60,000 TXV-NB 41 37 34 305 76 32 50 1 1/8 3/8

* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.** Rated in accordance with ARI Standard 270, section 5.3.6.

Split System CoolingSingle Phase – 1½ through 5 Tons

XR14

XR14

XR13

Page 22: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

SC-4For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Effective 1/1/06

Split System CoolingSingle Phase – 1½ through 5 Tons

XR 14 XR 14 XR 13Table SC-4-A — Features (2TTR4) (4TTR4) (2TTR3)• SEER’s up to ............................................................................................................................................. 14.00 14.00 14.00• Climatuff™ compressor ........................................................................................................................... ✔ ✔ ✔• Comfort”R”™ mode approved ................................................................................................................ ✔ ✔ ✔• DuraTuff™ base, fast complete drain, weatherproof ................................................................................ ✔ ✔ ✔

• Quick-Sess™ cabinet, service access & refrigerant connections with full coil protection ........................ ✔ ✔ ✔• Spine Fin™ coil ........................................................................................................................................ ✔ ✔ ✔• Compressor sound enclosure ................................................................................................................... ✔ ✔ ✔

• Compressor sump heat - factory installed ................................................................................................. 1½-2,3½-5 1½-2 5• Factory supplied charge ............................................................................................................................ R-22 R-410A R-22• Glossy corrosion resistant finish ............................................................................................................... ✔ ✔ ✔

• High pressure switch ................................................................................................................................. — ✔ —• Internal high / low pressure & temperature protection ............................................................................... ✔ ✔ ✔• Liquid line filter drier - factory installed ...................................................................................................... ✔ ✔ ✔

• Quick start kit - factory installed ................................................................................................................ 1½-2,5 1½-2,5 1½-2½,3½-5• Tarpaulin gray cabinet ............................................................................................................................... ✔ ✔ ✔• 10-year limited warranty on compressor, outdoor coil & 5 years on parts (Residential) ............................ ✔ ✔ ✔

• Extended warranties available ............................................................................................................... ✔ ✔ ✔

Table SC-4-B — Optional AccessoriesAY28X079 .............. Evap. Defrost Control Kit .............................................................................................. ✔ ✔ ✔BAYCCHT300 ........ Crankcase Heater Kit (Reciprocating Compressors) .................................................... — — 1½-2½,3½-4BAYCCHT301 ........ Crankcase Heater Kit (Scroll Compressors) ................................................................. 2½-3 2½-5 3BAYECMT001 ........ Extreme Condition Mounting Kit ................................................................................... ✔ ✔ ✔BAYISLT101 .......... Rubber Isolators ........................................................................................................... ✔ ✔ ✔BAYKSKT260 ........ Start Kit (Scroll Compressors) ...................................................................................... 2½-4 2½-4 3BAYLEGS002 ........ Snow Legs - Base and Cap 6" High (Black) ................................................................. ✔ ✔ ✔BAYLEGS003 ........ 4" Extension (Black) ..................................................................................................... ✔ ✔ ✔BAYLOAM103 ........ Low Ambient Kit ........................................................................................................... ✔ — ✔

BAYSEAC001 ........ Seacoast Kit ................................................................................................................. ✔ ✔ ✔TAYASCT501A12 . Anti-Short Cycle Timer ................................................................................................. ✔ ✔ ✔

Comfort Controls — See Comfort Controls/Zone Sensors Section1 Not for use with programmable thermostats2 Activated on Power Off.

Page 23: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

SC-5For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Effective 1/1/06

PHASED OUT

PHASED OUT

PHASED OUT

Split System CoolingSingle Phase – 1½ through 5 Tons

XR12

XR11

XR12

Table SC-5-A — XR12 Split System Cooling — Single PhaseNom. Cap. Required Uncrated Shipping Line Size

Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.

4TTR2018A1000A 200-230/1/60 18,000 .049 33 33 30 215 77 10 15 1/2 1/44TTR2024A1000A 200-230/1/60 24,000 .053 33 33 30 219 78 13 20 5/8 5/16

4TTR2030A1000A 208-230/1/60 30,000 .059 33 33 30 218 74 20 30 3/4 5/16

4TTR2036A1000A 208-230/1/60 36,000 .065 33 33 30 231 77 21 35 3/4 3/84TTR2042A1000A 208-230/1/60 42,000 .071 37 33 30 243 78 25 40 3/4 3/84TTR2048A1000A 208-230/1/60 48,000 .077 41 33 30 260 79 31 50 7/8 3/84TTR2060A1000A 208-230/1/60 60,000 11111 33 37 34 283 81 36 60 7/8 3/8

Table SC-5-B — XR12 Split System Cooling — Single PhaseNom. Cap. Required Uncrated Shipping Line Size

Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.

2TTR2018A1000A 200-230/1/60 18,000 .051 26 29 26 171 79 10 15 5/8 1/42TTR2024A1000A 200-230/1/60 24,000 .057 29 29 26 187 78 11 15 3/4 5/16

2TTR2030A1000A 208-230/1/60 30,000 .065 29 29 26 180 79 18 30 3/4 5/16

2TTR2036A1000A 208-230/1/60 36,000 .071 33 29 26 195 79 21 35 7/8 3/82TTR2042B1000A 208-230/1/60 42,000 .077 33 33 30 228 79 23 40 7/8 3/82TTR2048A1000A 208-230/1/60 48,000 .086 37 33 30 247 78 26 45 1 1/8 3/82TTR2060B1000A 208-230/1/60 60,000 11111 41 37 34 270 79 33 50 1 1/8 3/8

Table SC-5-C — XR11 Split System Cooling — Single PhaseNom. Cap. Required Uncrated Shipping Line Size

Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.

2TTR1018A1000A 200-230/1/60 18,000 .049 26 20 19 129 82 10 15 5/8 1/42TTR1024A1000A 200-230/1/60 24,000 .057 26 20 19 141 81 13 20 3/4 5/16

2TTR1030A1000A 200-230/1/60 30,000 .065 26 29 26 168 79 17 30 3/4 5/16

2TTR1036A1000A 200-230/1/60 36,000 .073 26 29 26 177 77 22 35 7/8 3/82TTR1042A1000A 200-230/1/60 42,000 .075 29 29 26 212 79 24 40 7/8 3/82TTR1048A1000A 200-230/1/60 48,000 .083 29 29 26 219 79 29 50 11/8 3/82TTR1060A1000A 200-230/1/60 60,000 11111 37 33 30 269 79 36 60 11/8 3/8

1 Indoor Metering device TXV only.* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.** Rated in accordance with ARI Standard 270, section 5.3.6.

Page 24: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

SC-6For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Effective 1/1/06

PH

AS

ED

OU

T

PH

ASED

OU

T

PH

AS

ED

OU

T

Split System CoolingSingle Phase – 1½ through 5 Tons

XR 12 XR 12 XR 11Table SC-6-A — Features (4TTR2) (2TTR2) (2TTR1)• SEER’s up to .......................................................................................................................................................................... 13 13 11.5• Climatuff™ compressor ........................................................................................................................................................ ✔ ✔ ✔• Comfort”R”™ mode approved .............................................................................................................................................. ✔ ✔ ✔• DuraTuff™ base, fast complete drain, weatherproof .............................................................................................................. ✔ ✔ ✔• Quick-Sess™ cabinet, service access & refrigerant connections with full coil protection ....................................................... ✔ ✔ ✔• Spine Fin™ coil ..................................................................................................................................................................... ✔ ✔ ✔• Factory installed start kit ......................................................................................................................................................... 1-2 & 5 1-2 —• Factory supplied charge ......................................................................................................................................................... R-410A R-22 R-22• Glossy corrosion resistant finish ............................................................................................................................................. ✔ ✔ ✔• High pressure switch .............................................................................................................................................................. — ✔ ✔• Internal high / low pressure & temperature protection ............................................................................................................. ✔ ✔ ✔• Liquid line filter drier - factory installed .................................................................................................................................... ✔ ✔ ✔• Tarpaulin gray cabinet ............................................................................................................................................................ ✔ ✔ ✔• 10-year limited warranty on compressor, outdoor coil & 5 years on parts (Residential) .......................................................... ✔ ✔ ✔

• Extended warranties available ............................................................................................................................................ ✔ ✔ ✔

Table SC-6-B — Optional AccessoriesAY28X079 ............... Evap. Defrost Control Kit .......................................................................................................................... ✔ ✔ ✔BAY24X045 ............. ID Fan Delay Relay Kit ............................................................................................................................. ✔ ✔ ✔BAYCCHT300 ......... Crankcase Heater Kit (Reciprocating Compressors) ................................................................................ 1½-2 1½-2 1½-5BAYCCHT301 ......... Crankcase Heater Kit (Scroll Compressors) ............................................................................................. 2½-5 2½-5 —BAYECMT001 ......... Extreme Condition Mounting Kit ............................................................................................................... ✔ ✔ ✔BAYISLT101 ............ Rubber Isolators ....................................................................................................................................... ✔ ✔ ✔BAYKSKT257 .......... Start Kit (Reciprocating Compressors) ..................................................................................................... — — 2½-5BAYKSKT260 .......... Start Kit (Scroll Compressors) .................................................................................................................. 2½-4 2½-5 —BAYKSKT261 .......... Start Kit (Base 1 & 2TTR1018, 024 only) (Reciprocating Compressors) ................................................... — — 1½-2BAYLEGS002 .......... Snow Legs - Base and Cap 6" High (Black) ............................................................................................. ✔ ✔ ✔BAYLEGS003 .......... 4" Extension (Black) ................................................................................................................................. ✔ ✔ ✔BAYLOAM103 ......... Low Ambient Kit ....................................................................................................................................... — ✔ 2½-5BAYLOAM104 ......... Low Ambient Kit with Start Kit .................................................................................................................. — — 1½-2BAYSDEN001 ......... Single Cylinder Compressor Enclosures .................................................................................................. — — 1½-2BAYSDEN003 ......... Small Scroll Compressor Enclosures ........................................................................................................ — 2½-4 —BAYSEAC001 ......... Seacoast Kit ............................................................................................................................................. ✔ ✔ ✔

Table SC-6-C — Comfort ControlsTAYASCT501A56 .. Anti-Short Cycle Timer ............................................................................................................................. ✔ ✔ ✔TAYSENS100A3 .... Outdoor Temp. Sensor (with case) ........................................................................................................... ✔ ✔ ✔TAYSTAT241 .......... Manual 2 Htg/1 Clg ................................................................................................................................... ✔ ✔ ✔TAYSTAT250B ........ Outdoor Thermostat ................................................................................................................................. ✔ ✔ ✔TAYSTAT300C ........ XT300C Prog., 7 Day, A/M,1Htg/1Clg ...................................................................................................... ✔ ✔ ✔TAYSTAT302C ........ XT302C Prog., 7 Day, A/M,2Htg/2Clg ...................................................................................................... ✔ ✔ ✔TAYSTAT340 .......... Prog., 5/2 Day, Manual, 1 Htg/1 Clg ......................................................................................................... ✔ ✔ ✔TAYSTAT350 .......... Prog., 5/2 Day, Manual, 2 (Gas) Htg/1Clg ................................................................................................ ✔ ✔ ✔TAYSTAT370 .......... Electronic, 1Htg (Gas) /1 Clg ( Non Prog.) ................................................................................................ ✔ ✔ ✔TAYSTAT3712 ....... Electronic, 1Htg (Elec.) /1 Clg ( Non Prog.) .............................................................................................. ✔ ✔ ✔TAYSTAT375 .......... Electronic, 2Htg (Gas/Elec.) 2 Clg (Non Prog.) Field Selectable ............................................................... ✔ ✔ ✔TAYSTAT380 .......... Electronic, 2 Htg (Gas)/ 1 Clg (Non Prog.) ................................................................................................ ✔ ✔ ✔TCONT200A ............ Electronic, 1Htg/1Clg (Gas/Elec./Oil) ........................................................................................................ ✔ ✔ ✔TCONT401A ............ 2Heat/1Clg (Heat Pump/A/C) ................................................................................................................... ✔ ✔ ✔TCONT402A ............ 3Heat/2Clg (Heat Pump/A/C) ................................................................................................................... ✔ ✔ ✔TCONT600A ............ 1Heat/1Clg (Heat Pump/A/C) ................................................................................................................... ✔ ✔ ✔TCONT602A ............ 2Heat/1Clg (Heat Pump/A/C) ................................................................................................................... ✔ ✔ ✔TCONT800A ............ 2Heat/1Clg (Heat Pump/A/C) ................................................................................................................... ✔ ✔ ✔TCONT802A ............ 3Heat/2Clg (Heat Pump/A/C) ................................................................................................................... ✔ ✔ ✔TCONT803A ............ 3Heat/2Clg (Heat Pump/A/C) w/Humidity Control ..................................................................................... ✔ ✔ ✔

1 Requires Subbase.2 Specifically designed for electric heat applications (instant on fan)3 Used with TAYSTAT300C, TAYSTAT302C4 Use with BAY28X182, BAY28X1835 Not for use with programmable thermostats6 Activated on Power Off.

Page 25: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

SC-7For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Effective 1/1/06

PHASED OUT

PHASED OUT

PHASED OUT

XB10

XB12

XB10

Split System CoolingSingle Phase – 1 through 5 Tons

XB13

Table SC-7-A — XB13 Split System Cooling — Single PhaseNom. Cap. Required Uncrated Shipping Line Size

Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.

2TTB3018A1000A 200-230/1/60 17,000 TXV-NB 26 29 26 182 76 8 15 5/8 1/42TTB3024A1000A 200-230/1/60 23,000 TXV-NB 33 29 26 195 78 12 20 3/4 5/16

2TTB3030A1000A 200-230/1/60 28,500 TXV-NB 33 33 30 225 78 13 20 3/4 5/16

2TTB3036A1000A 208-230/1/60 34,500 TXV-NB 33 33 30 220 76 18 30 7/8 3/82TTB3042A1000A 200-230/1/60 40,500 TXV-NB 33 37 34 283 79 21 35 7/8 3/82TTB3048A1000A 200-230/1/60 46,500 TXV-NB 41 37 34 307 79 25 40 1 1/8 3/82TTB3060A1000A 208-230/1/60 58,500 TXV-NB 41 37 34 303 79 32 50 1 1/8 3/8

Table SC-7-B — XB12 Split System Cooling — Single PhaseNom. Cap. Required Uncrated Shipping Line Size

Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.

2TTB2018A1000A 200-230/1/60 18,000 .051 26 29 26 172 81 10 15 5/8 1/42TTB2024A1000A 200-230/1/60 24,000 .057 29 29 26 188 82 11 15 3/4 5/16

2TTB2030A1000A 208-230/1/60 30,000 .065 29 29 26 180 79 18 30 3/4 5/16

2TTB2036A1000A 208-230/1/60 36,000 .071 33 29 26 195 79 21 35 7/8 3/82TTB2042A1000A 208-230/1/60 42,000 .077 33 33 30 216 N/A 23 40 7/8 3/82TTB2048A1000A 208-230/1/60 48,000 .086 37 33 30 248 78 26 45 11/8 3/82TTB2060A1000A 208-230/1/60 60,000 11111 37 33 30 271 79 38 60 11/8 3/8

Table SC-7-C — XB10 Split System Cooling — Single PhaseNom. Cap. Required Uncrated Shipping Line Size

Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.

2TTB0030A1000A 200-230/1/60 30,000 .065 26 29 26 169 81 17 30 3/4 5/16

2TTB0036A1000A 200-230/1/60 36,000 .071 26 29 26 175 80 20 35 7/8 3/82TTB0042A1000A 200-230/1/60 42,000 .075 26 29 26 208 81 23 40 7/8 3/82TTB0048A1000A 200-230/1/60 48,000 .080 26 29 26 218 82 26 45 11/8 3/82TTB0060A1000A 200-230/1/60 60,000 11111 33 33 30 256 83 35 60 11/8 3/8

Table SC-7-D — XB10 Split System Cooling — Single PhaseNom. Cap. Required Uncrated Shipping Line Size

Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.

TTB012C100A 200-230/1/60 12,000 .049 24 18 18 118 82 11 15 5/8 1/4TTB018C100A 200-230/1/60 18,000 .049 24 18 18 118 82 11 15 5/8 1/4TTB024C100A 208-230/1/60 24,000 .057 24 18 18 130 80 15 25 3/4 5/16

1 Indoor Metering device TXV only.* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.** Rated in accordance with ARI Standard 270, section 5.3.6.

Page 26: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

SC-8For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Effective 1/1/06

PH

AS

ED

OU

T

PH

AS

ED

OU

T

PH

AS

ED

OU

T

Split System CoolingSingle Phase – 1 through 5 Tons

See

Com

fort

Con

trol

s/ Z

one

Sen

sors

Sec

tion

XB 13 XB 12 XB 10 XB 10Table SC-8-A — Features (2TTB3) (2TTB2) (2TTB0) (TTB)• SEER’s up to ..................................................................................................................................................... 13.25 12.50 10.50 10.50• Climatuff™ compressor ................................................................................................................................... ✔ ✔ ✔ ✔• Comfort”R”™ mode approved ......................................................................................................................... ✔ ✔ ✔ ✔• DuraTuff™ base, fast complete drain, weatherproof ......................................................................................... ✔ ✔ ✔ ✔• Quick-Sess™ cabinet, service access & refrigerant connections with full coil protection .................................. ✔ ✔ ✔ ✔• Spine Fin™ coil ................................................................................................................................................ ✔ ✔ ✔ ✔• Compressor sump heat - factory installed .......................................................................................................... 5 — — —• Factory supplied charge .................................................................................................................................... R-22 R-22 R-22 R-22• Glossy corrosion resistant finish ........................................................................................................................ ✔ ✔ ✔ ✔• Internal high / low pressure & temperature protection ........................................................................................ ✔ ✔ ✔ ✔• Liquid line filter drier - factory installed ............................................................................................................... ✔ ✔ ✔ ✔• Polyslate gray cabinet ....................................................................................................................................... ✔ ✔ ✔ ✔• Quick start kit - factory installed ......................................................................................................................... 1½-2½,3½-5 1½-2 — —• 5 year limited warranty on compressor, outdoor coil & 5 years on parts (Residential) ........................................ ✔ ✔ ✔ ✔

• Extended warranties available ....................................................................................................................... ✔ ✔ ✔ ✔

Table SC-8-B — Optional AccessoriesAY28X079 ............... Evap. Defrost Control Kit ..................................................................................................... ✔ ✔ ✔ ✔BAYCCHT300 ......... Crankcase Heater Kit (Reciprocating Compressors) ........................................................... 1½-2½,3½-4 1½-2 2½-5 1-2BAYCCHT301 ......... Crankcase Heater Kit (Scroll Compressors) ........................................................................ 3 2½-5 — —BAYECMT001 ......... Extreme Condition Mounting Kit .......................................................................................... ✔ ✔ ✔ —BAYISLT100 ............ Rubber Isolators (012, 018 & 024 only) ............................................................................... — — — ✔BAYISLT101 ............ Rubber Isolators .................................................................................................................. ✔ ✔ ✔ —BAYKSKT257 .......... Start Kit (Reciprocating Compressors) ................................................................................ — — 2½-5 —BAYKSKT260 .......... Start Kit (Scroll Compressors) ............................................................................................. 3 2½-5 — —BAYKSKT261 .......... Start Kit (18" only - TTB012,018 & 024) (Reciprocating Compressors) ................................ — — — 1-2BAYLEGS002 .......... Snow Legs - Base and Cap 6" High (Black) ........................................................................ ✔ ✔ ✔ —BAYLEGS003 .......... 4" Extension (Black) ............................................................................................................ ✔ ✔ ✔ —BAYLOAM103 ......... Low Ambient Kit .................................................................................................................. ✔ ✔ ✔ —BAYLOAM104 ......... Low Ambient Control Kit ...................................................................................................... — — — ✔BAYSDEN001 ......... Single Cylinder Compressor Enclosures ............................................................................. 1½-2½ 1½-2 2½-3 1-2BAYSDEN002 ......... Two Cylinder Compressor Enclosures ................................................................................. — — 3½-5 —BAYSDEN003 ......... Small Scroll Compressor Enclosures ................................................................................... 3 2½-4 — —BAYSDEN004 ......... Large Scroll Compressor Enclosures .................................................................................. 5 5 — —BAYSEAC001 ......... Seacoast Kit ........................................................................................................................ ✔ ✔ ✔ —

Table SC-8-C — Comfort ControlsAY28X092 ............... Heat/Cool ( Horiz.) Therm. .................................................................................................. ✔ ✔ ✔BAYSTAT304 .......... Cooling Only w/ Fan Switch ................................................................................................. ✔ ✔ ✔BAYSTAT305 .......... Heat/Cool ( Vertical ) Therm. ............................................................................................... ✔ ✔ ✔TAYASCT501A56 .. Anti-Short Cycle Timer ........................................................................................................ ✔ ✔ ✔TAYSENS100A3 .... Outdoor Temp. Sensor (with case) ...................................................................................... ✔ ✔ ✔TAYSTAT250B ........ Outdoor Thermostat ............................................................................................................ ✔ ✔ ✔

TAYSTAT300C ........ XT300C Prog., 7 Day, A/M,1Htg/1Clg .......................................................................... ✔ ✔ ✔

TAYSTAT370 .......... Electronic, 1Htg (Gas) /1 Clg ( Non Prog.) ........................................................................... ✔ ✔ ✔TAYSTAT3712 ....... Electronic, 1Htg (Elec.) /1 Clg ( Non Prog.) ......................................................................... ✔ ✔ ✔TCONT200A ............ Electronic, 1Htg/1Clg (Gas/Elec./Oil) ................................................................................... ✔ ✔ ✔TCONT401A ............ 2Heat/1Clg (Heat Pump/A/C) .............................................................................................. ✔ ✔ ✔TCONT402A ............ 3Heat/2Clg (Heat Pump/A/C) .............................................................................................. ✔ ✔ ✔TCONT600A ............ 1Heat/1Clg (Heat Pump/A/C) .............................................................................................. ✔ ✔ ✔TCONT602A ............ 2Heat/1Clg (Heat Pump/A/C) .............................................................................................. ✔ ✔ ✔TCONT800A ............ 2Heat/1Clg (Heat Pump/A/C) .............................................................................................. ✔ ✔ ✔TCONT802A ............ 3Heat/2Clg (Heat Pump/A/C) .............................................................................................. ✔ ✔ ✔TCONT803A ............ 3Heat/2Clg (Heat Pump/A/C) w/Humidity Control ................................................................ ✔ ✔ ✔

1 Requires Subbase.2 Specifically designed for electric heat applications (instant on fan)3 Used with TAYSTAT300C, TAYSTAT302C4 Use with BAY28X182, BAY28X1835 Not for use with programmable thermostats6 Activated on Power Off.

Page 27: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

SC-9For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Effective 1/1/06

PHASED OUT

2TTA0

2TTA2

Split System CoolingThree Phase – 2½ through 6 Tons

2TTA3

Table SC-9-A — 2TTA0 Split System Cooling — Three PhaseNom. Cap. Required Uncrated Shipping Line Size

Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.

2TTA0030A3000A 200-230/3/60 30,000 .065 26 29 26 175 80 13 20 3/4 5/16

2TTA0036A3000A 200-230/3/60 36,000 .073 26 29 26 179 79 15 25 7/8 3/8

2TTA0042A3000A 200-230/3/60 42,000 .075 29 29 26 211 83 18 30 7/8 3/8

2TTA0048A3000A 200-230/3/60 48,000 .083 29 29 26 216 82 20 30 11/8 3/8

2TTA0060A3000A 200-230/3/60 60,000 11111 33 33 30 255 82 27 45 11/8 3/8

2TTA0072A3000A 200-230/3/60 72,000 11111 41 37 34 297 81 26 45 11/8 3/8

2TTA0030A4000A 460/3/60 30,000 .065 26 29 26 175 80 7 15 3/4 5/16

2TTA0036A4000A 460/3/60 36,000 .073 26 29 26 179 79 8 15 7/8 3/8

2TTA0042A4000A 460/3/60 42,000 .075 29 29 26 211 83 9 15 7/8 3/8

2TTA0048A4000A 460/3/60 48,000 .083 29 29 26 216 82 10 15 11/8 3/8

2TTA0060A4000A 460/3/60 60,000 11111 33 33 30 255 82 13 20 11/8 3/8

2TTA0072A4000A 460/3/60 72,000 11111 41 37 34 297 81 14 20 11/8 3/8

Table SC-9-B — 2TTA3 Split System Cooling — Three PhaseNom. Cap. Required Uncrated Shipping Line Size

Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.

2TTA3030A3000A 200-230/3/60 30,000 TXV-NB 33 33 30 225 78 9 15 3/4 5/16

2TTA3036A3000A 200-230/3/60 36,000 TXV-NB 33 33 30 216 76 13 20 7/83/8

2TTA3042A3000A 200-230/3/60 42,000 TXV-NB 33 37 34 245 79 13 20 7/83/8

2TTA3048A3000A 200-230/3/60 48,000 TXV-NB 41 37 34 303 79 16 25 1 1/83/8

2TTA3060A3000A 200-230/3/60 60,000 TXV-NB 41 37 34 292 79 23 40 1 1/83/8

2TTA3030A4000A 460/3/60 30,000 TXV-NB 33 33 30 225 78 5 15 3/4 5/16

2TTA3036A4000A 460/3/60 36,000 TXV-NB 33 33 30 219 76 7 15 7/83/8

2TTA3042A4000A 460/3/60 42,000 TXV-NB 33 37 34 246 79 7 15 7/83/8

2TTA3048A4000A 460/3/60 48,000 TXV-NB 41 37 34 305 79 9 15 1 1/83/8

2TTA3060A4000A 460/3/60 60,000 TXV-NB 41 37 34 293 79 10 15 1 1/83/8

Table SC-9-C — 2TTA2 Split System Cooling — Three PhaseNom. Cap. Required Uncrated Shipping Line Size

Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.

2TTA2030A3000A 200-230/3/60 30,000 .065 29 29 26 177 79 12 20 3/4 5/16

2TTA2036A3000A 200-230/3/60 36,000 .071 33 29 26 192 79 15 25 7/8 3/8

2TTA2042B3000A 200-230/3/60 42,000 .077 33 33 30 212 79 17 25 7/8 3/8

2TTA2048A3000A 200-230/3/60 48,000 .086 37 33 30 242 78 20 35 11/8 3/8

2TTA2060A3000A 200-230/3/60 60,000 11111 37 33 30 258 79 24 40 11/8 3/8

2TTA2030A4000A 460/3/60 30,000 .065 29 29 26 180 79 6 15 3/4 5/16

2TTA2036A4000A 460/3/60 36,000 .071 33 29 26 191 79 8 15 7/8 3/8

2TTA2042B4000A 460/3/60 42,000 .077 33 33 30 212 79 8 15 7/8 3/8

2TTA2048A4000A 460/3/60 48,000 .086 37 33 30 241 78 10 15 11/8 3/8

2TTA2060A4000A 460/3/60 60,000 11111 37 33 30 258 79 12 20 11/8 3/8

1 Indoor Metering device TXV only.* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.** Rated in accordance with ARI Standard 270, section 5.3.6.

Page 28: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

SC-10For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Effective 1/1/06

PH

AS

ED

OU

TP

HA

SE

D O

UT

PH

AS

ED

OU

T

Split System CoolingThree Phase – 2½ through 6 Tons

Table SC-10-A — Features 2TTA0 2TTA3 2TTA2• SEER's up to .................................................................................................................................................................. 11.75 14.50 12.50• Climatuff™ compressor ................................................................................................................................................ ✔ ✔ ✔• Comfort”R”™ mode approved ...................................................................................................................................... ✔ ✔ ✔• DuraTuff™ base, fast complete drain, weatherproof ...................................................................................................... ✔ ✔ ✔• Quick-Sess™ cabinet, service access & refrigerant connections with full coil protection ............................................... ✔ ✔ ✔• Spine Fin™ coil ............................................................................................................................................................. ✔ ✔ ✔• Compressor sump heat - factory installed ....................................................................................................................... 2½-6 2½-5 2½-5• Factory supplied charge ................................................................................................................................................. R-22 R-22 R-22• Glossy corrosion resistant finish ..................................................................................................................................... ✔ ✔ ✔• Internal high / low pressure & temperature protection ..................................................................................................... ✔ ✔ ✔• Liquid line filter drier - factory installed ............................................................................................................................ ✔ ✔ ✔• Low pressure switch ....................................................................................................................................................... ✔ ✔ —• PolySlate gray cabinet .................................................................................................................................................... ✔ ✔ ✔• 5-year limited warranty on compressor, and 1 year on coil and parts (Commercial) ....................................................... ✔ ✔ ✔• 5-year limited warranty on compressor, coil and 1 year on parts (Residential) ................................................................ ✔ ✔ ✔• Extended warranties available .................................................................................................................................... ✔ ✔ ✔

Table SC-10-B — Optional AccessoriessAY28X079 .................................... Evaporator Defrost Control .......................................................................................... ✔ ✔ ✔BAYECMT001 .............................. Extreme Condition Mounting Kit ................................................................................... ✔ ✔ ✔BAYISLT101 ................................. Rubber Isolators ........................................................................................................... ✔ ✔ ✔BAYLEGS002 ............................... Snow Legs - Base and Cap 6" High (Black) ................................................................. ✔ ✔ ✔BAYLEGS003 ............................... 4" Extension (Black) ..................................................................................................... ✔ ✔ ✔BAYLOAM103 .............................. Electronic Head Pressure Control ................................................................................ ✔ ✔ ✔BAYSDEN001 .............................. Single Cylinder Compressor Enclosures ...................................................................... 2½-3 2½ —BAYSDEN002 .............................. Two Cylinder Compressor Enclosures ......................................................................... 3½-5 3½-4 —BAYSDEN003 .............................. Small Scroll Compressor Enclosures ........................................................................... — 3 2½-4BAYSDEN004 .............................. Large Scroll Compressor Enclosures ........................................................................... 6 5 5BAYSEAC001 .............................. Seacoast Kit ................................................................................................................. ✔ ✔ ✔TAYASCT501A12 ...................... Anti-Short Cycle Timer ................................................................................................. ✔ ✔ ✔

Table SC-10-C — Comfort ControlsTAYSENS100A ........................... Outdoor Temp. Sensor (with case) .............................................................................. ✔TAYSTAT241 ............................... Manual 2 Stg Htg/1 Clg ................................................................................................ ✔TAYSTAT250B ............................. Outdoor Thermostat ..................................................................................................... ✔TAYSTAT300C ............................ XT300C Prog.,7 Day,A/M,1Htg/1Clg ............................................................................ ✔TAYSTAT340 ............................... Prog., 5/2 Day, Manual, 1 Htg/1 Clg ............................................................................. ✔TAYSTAT350 ............................... Prog., 5/2 Day, Manual, 2 (Gas) Htg/1 Clg ................................................................... ✔TAYSTAT370 ............................... Electronic, 1Htg(Gas)/1Clg(Non Prog.) ........................................................................ ✔TAYSTAT371 ............................... Electronic, 1Htg(Elec)/1Clg(Non Prog.) ........................................................................ ✔TAYSTAT380 ............................... Electronic, 2 Htg (Gas) 1 Clg(Non Prog.) ..................................................................... ✔TCONT200A ................................. Electronic, 1Htg/1Clg (Gas/Elec./Oil) ........................................................................... ✔TCONT401A ................................. 2Heat/1Clg (Heat Pump/A/C) ....................................................................................... ✔TCONT402A ................................. 3Heat/2Clg (Heat Pump/A/C) ....................................................................................... ✔TCONT600A ................................. 1Heat/1Clg (Heat Pump/A/C) ....................................................................................... ✔TCONT602A ................................. 2Heat/1Clg (Heat Pump/A/C) ....................................................................................... ✔TCONT800A ................................. 2Heat/1Clg (Heat Pump/A/C) ....................................................................................... ✔TCONT802A ................................. 3Heat/2Clg (Heat Pump/A/C) ....................................................................................... ✔TCONT803A ................................. 3Heat/2Clg (Heat Pump/A/C) w/Humidity Control ........................................................ ✔

1 Do not use with programmable thermostats.2 Activated on Power Off.

See

Com

fort

Con

trol

s/ Z

one

Sen

sors

Sec

tion

See

Com

fort

Con

trol

s/ Z

one

Sen

sors

Sec

tion

Page 29: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

SC-11For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Effective 1/1/06

Table SC-11-A — TTA Split System Cooling — Single CompressorFactory Nom. Cap. Uncrated Shipping Line Size

Model Installed Power Cooling Dimensions(in.) Mfg. Weight Sound11111 Max. OD ODNumber Option Supply (BTUH) H W L Plant (lbs.) Rating MCA* Fuse* Gas Liq.

TTA090A300F — 208/230/3/60 92,000 39 34 41 SPR 370 8.8 34.5 50 13/8 1/2TTA090A30SF Epoxy Coil 208-230/3/60 92,000 39 34 41 SPR 370TTA090A30RF ReliaTel™, No LCI Board 208-230/3/60 92,000 39 34 41 SPR 370TTA090A30TF ReliaTel™, No LCI Board W/Epoxy Coil 208-230/3/60 92,000 39 34 41 SPR 370TTA090A30UF ReliaTel™, W/LCI Board 208-230/3/60 92,000 39 34 41 SPR 370TTA090A30WF ReliaTel™, W/LCI Board & Epoxy Coil 208-230/3/60 92,000 39 34 41 SPR 370

TTA120A300F — 208/230/3/60 128,000 39 38 51 SPR 443 8.8 48.1 70 13/8 1/2TTA120A30SF Epoxy Coil 208-230/3/60 128,000 39 38 51 SPR 443TTA120A30RF ReliaTel™, No LCI Board 208-230/3/60 128,000 39 38 51 SPR 443TTA120A30TF ReliaTel™, No LCI Board W/Epoxy Coil 208-230/3/60 128,000 39 38 51 SPR 443TTA120A30UF ReliaTel™, W/LCI Board 208-230/3/60 128,000 39 38 51 SPR 443TTA120A30WF ReliaTel™, W/LCI Board & Epoxy Coil 208-230/3/60 128,000 39 38 51 SPR 443

TTA090A400F — 460/3/60 92,000 39 34 41 SPR 370 8.8 18.1 25 13/8 1/2TTA090A40SF Epoxy Coil 460/3/60 92,000 39 34 41 SPR 370TTA090A40RF ReliaTel™, No LCI Board 460/3/60 92,000 39 34 41 SPR 370TTA090A40TF ReliaTel™, No LCI Board W/Epoxy Coil 460/3/60 92,000 39 34 41 SPR 370TTA090A40UF ReliaTel™, W/LCI Board 460/3/60 92,000 39 34 41 SPR 370TTA090A40WF ReliaTel™, W/LCI Board & Epoxy Coil 460/3/60 92,000 39 34 41 SPR 370

TTA120A400F — 460/3/60 128,000 39 38 51 SPR 443 8.8 23.3 35 13/8 1/2TTA120A40SF Epoxy Coil 460/3/60 128,000 39 38 51 SPR 443TTA120A40RF ReliaTel™, No LCI Board 460/3/60 128,000 39 38 51 SPR 443TTA120A40TF ReliaTel™, No LCI Board W/Epoxy Coil 460/3/60 128,000 39 38 51 SPR 443TTA120A40UF ReliaTel™, W/LCI Board 460/3/60 128,000 39 38 51 SPR 443TTA120A40WF ReliaTel™, W/LCI Board & Epoxy Coil 460/3/60 128,000 39 38 51 SPR 443

TTA090AW00F — 575/3/60 92,000 39 34 41 SPR 370 8.8 14.5 20 13/8 1/2TTA090AW0SF Epoxy Coil 575/3/60 92,000 39 34 41 SPR 370TTA090AW0RF ReliaTel™, No LCI Board 575/3/60 92,000 39 34 41 SPR 370TTA090AW0TF ReliaTel™, No LCI Board W/Epoxy Coil 575/3/60 92,000 39 34 41 SPR 370TTA090AW0UF ReliaTel™, W/LCI Board 575/3/60 92,000 39 34 41 SPR 370TTA090AW0WF ReliaTel™, W/LCI Board & Epoxy Coil 575/3/60 92,000 39 34 41 SPR 370

TTA120AW00F — 575/3/60 128,000 39 38 51 SPR 443 8.8 18.8 25 13/8 1/2TTA120AW0SF Epoxy Coil 575/3/60 128,000 39 38 51 SPR 443TTA120AW0RF ReliaTel™, No LCI Board 575/3/60 128,000 39 38 51 SPR 443TTA120AW0TF ReliaTel™, No LCI Board W/Epoxy Coil 575/3/60 128,000 39 38 51 SPR 443TTA120AW0UF ReliaTel™, W/LCI Board 575/3/60 128,000 39 38 51 SPR 443TTA120AW0WF ReliaTel™, W/LCI Board & Epoxy Coil 575/3/60 128,000 39 38 51 SPR 4431 Sound rated in accordance with A.R.I. Standard 270.* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.

TTA – 7½ through 20 Tons

Split System CoolingThree Phase – 7½ through 20 Tons

• New ReliaTel™ controls option• (1) Trane 3-D® Scroll compressor (TTA090-

120A)• (2) Trane Scroll compressors (TTA120-

240B) with independent refrigerant circuits• (2) Manifolded Scroll compressors with

unloading capability (TTA120 & 180C)• Single point power supply• Compressor motor overload protection• Control transformer• High and low pressure cut-out switches• Liquid line filter drier, factory installed• Service valves with pressure taps

• Internal pressure relief valves(TTA120B,120C,150B)

• Holding charge of Nitrogen• Copper tube, aluminum plate fin coils• Low ambient cooling to 50°F as shipped.• Low ambient cooling to 0°F with accessory

head pressure control• Mounting/lifting rails under base• UL listed• 5 year compressor warranty

(TTA090-120A/TTA120-180B/TTA120-180C)• 1 year compressor warranty (TTA240B)• 1 year limited parts warranty• Optional Extended Warranties

Page 30: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

SC-12For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Effective 1/1/06

Split System CoolingThree Phase – 10 through 20 Tons

Table SC-12-A — TTA Split System Cooling — Dual CompressorFactory Nom. Cap. Uncrated Shipping Line Size

Model Installed Power Cooling Dimensions(in.) Mfg. Weight Sound11111 Max. OD ODNumber Option Supply (BTUH) H W L Plant (lbs.) Rating MCA* Fuse* Gas Liq.

TTA120B300E — 208-230/3/60 126,000 39 38 51 SPR 481 8.8 47.9 60 11/8 3/8TTA120B30SE Epoxy Coil 208-230/3/60 126,000 39 38 51 SPR 481TTA120B30RE ReliaTel™, No LCI Board 208-230/3/60 126,000 39 38 51 SPR 481TTA120B30TE ReliaTel™, No LCI Board w/Epoxy Coil 208-230/3/60 126,000 39 38 51 SPR 481TTA120B30UE ReliaTel™, W/LCI Board 208-230/3/60 126,000 39 38 51 SPR 481TTA120B30WE ReliaTel™, W/LCI Board & Epoxy Coil 208-230/3/60 126,000 39 38 51 SPR 481

TTA150B300E — 208/230/3/60 148,000 39 38 51 SPR 481 8.8 55.5 70 11/8 3/8TTA150B30SE Epoxy Coil 208-230/3/60 148,000 39 38 51 SPR 481TTA150B30RE ReliaTel™, No LCI Board 208-230/3/60 148,000 39 38 51 SPR 481TTA150B30TE ReliaTel™, No LCI Board w/Epoxy Coil 208-230/3/60 148,000 39 38 51 SPR 481TTA150B30UE ReliaTel™, W/LCI Board 208-230/3/60 148,000 39 38 51 SPR 481TTA150B30WE ReliaTel™, W/LCI Board & Epoxy Coil 208-230/3/60 148,000 39 38 51 SPR 481

TTA180B300F — 208/230/3/60 182,000 39 34 88 SPR 764 8.8 62.7 80 13/8 1/2TTA180B30SF Epoxy Coil 208-230/3/60 182,000 39 34 88 SPR 764TTA180B30RF ReliaTel™, No LCI Board 208-230/3/60 182,000 39 34 88 SPR 764TTA180B30TF ReliaTel™, No LCI Board w/Epoxy Coil 208-230/3/60 182,000 39 34 88 SPR 764TTA180B30UF ReliaTel™, W/LCI Board 208-230/3/60 182,000 39 34 88 SPR 764TTA180B30WF ReliaTel™, W/LCI Board & Epoxy Coil 208-230/3/60 182,000 39 34 88 SPR 764

TTA240B300F — 208/230/3/60 246,000 45 44 94 SPR 915 8.8 87.8 100 13/8 1/2TTA240B30SF Epoxy Coil 208-230/3/60 246,000 45 44 94 SPR 948TTA240B30RF ReliaTel™, No LCI Board 208-230/3/60 246,000 45 44 94 SPR 948TTA240B30TF ReliaTel™, No LCI Board w/Epoxy Coil 208-230/3/60 246,000 45 44 94 SPR 948TTA240B30UF ReliaTel™, W/LCI Board 208-230/3/60 246,000 45 44 94 SPR 948TTA240B30WF ReliaTel™, W/LCI Board & Epoxy Coil 208-230/3/60 246,000 45 44 94 SPR 948

TTA120B400E — 460/3/60 126,000 39 38 51 SPR 481 8.8 23.9 30 11/8 3/8TTA120B40SE Epoxy Coil 460/3/60 126,000 39 38 51 SPR 481TTA120B40RE ReliaTel™, No LCI Board 460/3/60 126,000 39 38 51 SPR 481TTA120B40TE ReliaTel™, No LCI Board w/Epoxy Coil 460/3/60 126,000 39 38 51 SPR 481TTA120B40UE ReliaTel™, W/LCI Board 460/3/60 126,000 39 38 51 SPR 481TTA120B40WE ReliaTel™, W/LCI Board & Epoxy Coil 460/3/60 126,000 39 38 51 SPR 481

TTA150B400E — 460/3/60 148,000 39 38 51 SPR 481 8.8 28.1 35 11/8 3/8TTA150B40SE Epoxy Coil 460/3/60 148,000 39 38 51 SPR 481TTA150B40RE ReliaTel™, No LCI Board 460/3/60 148,000 39 38 51 SPR 481TTA150B40TE ReliaTel™, No LCI Board w/Epoxy Coil 460/3/60 148,000 39 38 51 SPR 481TTA150B40UE ReliaTel™, W/LCI Board 460/3/60 148,000 39 38 51 SPR 481TTA150B40WE ReliaTel™, W/LCI Board & Epoxy Coil 460/3/60 148,000 39 38 51 SPR 481

TTA180B400F — 460/3/60 182,000 39 34 88 SPR 764 8.8 32.9 45 13/8 1/2TTA180B40SF Epoxy Coil 460/3/60 182,000 39 34 88 SPR 764TTA180B40RF ReliaTel™, No LCI Board 460/3/60 182,000 39 34 88 SPR 764TTA180B40TF ReliaTel™, No LCI Board w/Epoxy Coil 460/3/60 182,000 39 34 88 SPR 764TTA180B40UF ReliaTel™, W/LCI Board 460/3/60 182,000 39 34 88 SPR 764TTA180B40WF ReliaTel™, W/LCI Board & Epoxy Coil 460/3/60 182,000 39 34 88 SPR 764

TTA240B400F — 460/3/60 246,000 45 44 94 SPR 915 8.8 42.5 50 13/8 1/2TTA240B40SF Epoxy Coil 460/3/60 246,000 45 44 94 SPR 915TTA240B40RF ReliaTel™, No LCI Board 460/3/60 246,000 45 44 94 SPR 915TTA240B40TF ReliaTel™, No LCI Board w/Epoxy Coil 460/3/60 246,000 45 44 94 SPR 915TTA240B40UF ReliaTel™, W/LCI Board 460/3/60 246,000 45 44 94 SPR 915TTA240B40WF ReliaTel™, W/LCI Board & Epoxy Coil 460/3/60 246,000 45 44 94 SPR 9151 Sound rated in accordance with A.R.I. Standard 270.* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.

Page 31: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

SC-13For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Effective 1/1/06

Split System CoolingThree Phase – 10 through 20 Tons

Table SC-13-A — TTA Split System Cooling — Dual Compressor (continued)Factory Nom. Cap. Uncrated Shipping Line Size

Model Installed Power Cooling Dimensions(in.) Mfg. Weight Sound11111 Max. OD ODNumber Option Supply (BTUH) H W L Plant (lbs.) Rating MCA* Fuse* Gas Liq.

TTA120BW00E — 575/3/60 126,000 39 38 51 SPR 481 8.8 19.1 25 11/8 3/8TTA120BW0SE Epoxy Coil 575/3/60 126,000 39 38 51 SPR 481TTA120BW0RE ReliaTel™, No LCI Board 575/3/60 126,000 39 38 51 SPR 481TTA120BW0TE ReliaTel™, No LCI Board w/Epoxy Coil 575/3/60 126,000 39 38 51 SPR 481TTA120BW0UE ReliaTel™, W/LCI Board 575/3/60 126,000 39 38 51 SPR 481TTA120BW0WE ReliaTel™, W/LCI Board & Epoxy Coil 575/3/60 126,000 39 38 51 SPR 481

TTA150BW00E — 575/3/60 148,000 39 38 51 SPR 481 8.8 21.6 25 11/8 3/8TTA150BW0SE Epoxy Coil 575/3/60 148,000 39 38 51 SPR 481TTA150BW0RE ReliaTel™, No LCI Board 575/3/60 148,000 39 38 51 SPR 481TTA150BW0TE ReliaTel™, No LCI Board w/Epoxy Coil 575/3/60 148,000 39 38 51 SPR 481TTA150BW0UE ReliaTel™, W/LCI Board 575/3/60 148,000 39 38 51 SPR 481TTA150BW0WE ReliaTel™, W/LCI Board & Epoxy Coil 575/3/60 148,000 39 38 51 SPR 481

TTA180BW00F — 575/3/60 182,000 39 34 88 SPR 764 8.8 26.3 35 13/8 1/2TTA180BW0SF Epoxy Coil 575/3/60 182,000 39 34 88 SPR 764TTA180BW0RF ReliaTel™, No LCI Board 575/3/60 182,000 39 34 88 SPR 764TTA180BW0TF ReliaTel™, No LCI Board w/Epoxy Coil 575/3/60 182,000 39 34 88 SPR 764TTA180BW0UF ReliaTel™, W/LCI Board 575/3/60 182,000 39 34 88 SPR 764TTA180BW0WF ReliaTel™, W/LCI Board & Epoxy Coil 575/3/60 182,000 39 34 88 SPR 764

TTA240BW00F — 575/3/60 246,000 45 44 94 SPR 915 8.8 34.2 45 13/8 1/2TTA240BW0SF Epoxy Coil 575/3/60 246,000 45 44 94 SPR 915TTA240BW0RF ReliaTel™, No LCI Board 575/3/60 246,000 45 44 94 SPR 915TTA240BW0TF ReliaTel™, No LCI Board w/Epoxy Coil 575/3/60 246,000 45 44 94 SPR 915TTA240BW0UF ReliaTel™, W/LCI Board 575/3/60 246,000 45 44 94 SPR 915TTA240BW0WF ReliaTel™, W/LCI Board & Epoxy Coil 575/3/60 246,000 45 44 94 SPR 9151 Sound rated in accordance with A.R.I. Standard 270.* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.

Page 32: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

SC-14For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Effective 1/1/06

Split System CoolingThree Phase – 10 through 15 Tons

Table SC-14-A — TTA Split System Cooling — Dual Manifolded Compressors with Single Refrigerant CircuitsModel Installed Power Cooling Dimensions(in.) Mfg. Weight Sound11111 Max. OD ODNumber Option Supply (BTUH) H W L Plant (lbs.) Rating MCA* Fuse* Gas Liq.

TTA120C300G — 208-230/3/60 126,000 39 38 51 SPR 492 8.8 49.4 60 13/8 1/2TTA120C30SG Epoxy Coil 208-230/3/60 126,000 39 38 51 SPR 492TTA120C30RG ReliaTel™, No LCI Board 208-230/3/60 126,000 39 38 51 SPR 492TTA120C30TG ReliaTel™, No LCI Board w/Epoxy Coil 208-230/3/60 126,000 39 38 51 SPR 492TTA120C30UG ReliaTel™, W/LCI Board 208-230/3/60 126,000 39 38 51 SPR 492TTA120C30WG ReliaTel™, W/LCI Board & Epoxy Coil 208-230/3/60 126,000 39 38 51 SPR 492

TTA180C300G — 208-230/3/60 182,000 39 34 88 SPR 764 8.8 62.7 80 15/8 5/8TTA180C30SG Epoxy Coil 208-230/3/60 182,000 39 34 88 SPR 764TTA180C30RG ReliaTel™, No LCI Board 208-230/3/60 182,000 39 34 88 SPR 764TTA180C30TG ReliaTel™, No LCI Board w/Epoxy Coil 208-230/3/60 182,000 39 34 88 SPR 764TTA180C30UG ReliaTel™, W/LCI Board 208-230/3/60 182,000 39 34 88 SPR 764TTA180C30WG ReliaTel™, W/LCI Board & Epoxy Coil 208-230/3/60 182,000 39 34 88 SPR 764v

TTA120C400G — 460/3/60 126,000 39 38 51 SPR 492 8.8 25.2 30 13/8 1/2TTA120C40SG Epoxy Coil 460/3/60 126,000 39 38 51 SPR 492TTA120C40RG ReliaTel™, No LCI Board 460/3/60 126,000 39 38 51 SPR 492TTA120C40TG ReliaTel™, No LCI Board w/Epoxy Coil 460/3/60 126,000 39 38 51 SPR 492TTA120C40UG ReliaTel™, W/LCI Board 460/3/60 126,000 39 38 51 SPR 492TTA120C40WG ReliaTel™, W/LCI Board & Epoxy Coil 460/3/60 126,000 39 38 51 SPR 492

TTA180C400G — 460/3/60 182,000 39 34 88 SPR 764 8.8 32.9 45 15/8 5/8TTA180C40SG Epoxy Coil 460/3/60 182,000 39 34 88 SPR 764TTA180C40RG ReliaTel™, No LCI Board 460/3/60 182,000 39 34 88 SPR 764TTA180C40TG ReliaTel™, No LCI Board w/Epoxy Coil 460/3/60 182,000 39 34 88 SPR 764TTA180C40UG ReliaTel™, W/LCI Board 460/3/60 182,000 39 34 88 SPR 764TTA180C40WG ReliaTel™, W/LCI Board & Epoxy Coil 460/3/60 182,000 39 34 88 SPR 764

TTA120CW00G — 575/3/60 126,000 39 38 51 SPR 492 8.8 19.8 25 13/8 1/2TTA120CW0SG Epoxy Coil 575/3/60 126,000 39 38 51 SPR 492TTA120CW0RG ReliaTel™, No LCI Board 575/3/60 126,000 39 38 51 SPR 492TTA120CW0TG ReliaTel™, No LCI Board w/Epoxy Coil 575/3/60 126,000 39 38 51 SPR 492TTA120CW0UG ReliaTel™, W/LCI Board 575/3/60 126,000 39 38 51 SPR 492TTA120CW0WG ReliaTel™, W/LCI Board & Epoxy Coil 575/3/60 126,000 39 38 51 SPR 492

TTA180CW00G — 575/3/60 182,000 39 34 88 SPR 764 8.8 26.3 35 15/8 5/8TTA180CW0SG Epoxy Coil 575/3/60 182,000 39 34 88 SPR 764TTA180CW0RG ReliaTel™, No LCI Board 575/3/60 182,000 39 34 88 SPR 764TTA180CW0TG ReliaTel™, No LCI Board w/Epoxy Coil 575/3/60 182,000 39 34 88 SPR 764TTA180CW0UG ReliaTel™, W/LCI Board 575/3/60 182,000 39 34 88 SPR 764TTA180CW0WG ReliaTel™, W/LCI Board & Epoxy Coil 575/3/60 182,000 39 34 88 SPR 7641 Sound rated in accordance with A.R.I. Standard 270.* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.

Page 33: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

SC-15For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Effective 1/1/06

Table SC-15-A — Optional AccessoriesModelNumber Description Used With

BAY24X042 ....................... Fan Control Relay .......................................... TTA090-120A, 120-240B, 120-180C(Outdoor Thermostat 45°F to -10°F)

BAYASCT00139 ............. Anti-Short-Cycle Timer ................................... TTA090-120A, 120-240B, 120-180CBAYGARD024A ................ Coil Guard Kit ................................................. TTA090ABAYGARD026A ................ Coil Guard Kit ................................................. TTA150B, TTA120A, B, CBAYGARD039A ................ Coil Guard Kit ................................................. TTA180B, CBAYGARD042A ................ Coil Guard Kit ................................................. TTA240BBAYHGBP002C1 ............. Hot Gas Bypass Kit ........................................ TTA090-120ABAYHGBP003C12 .......... Hot Gas Bypass Kit ........................................ TTA180B, C, TTA240B, TTA120B, C; TTA150BBAYISLT004A ................... Rubber-In-Shear Isolators .............................. TTA090ABAYISLT005A ................... Rubber-In-Shear Isolators .............................. TTA120A, B, CBAYISLT009A ................... Rubber-In-Shear Isolators .............................. TTA150-180B, TTA180CBAYISLT010A ................... Rubber-In-Shear Isolators .............................. TTA240BBAYISLT023A ................... Steel Spring Isolators ..................................... TTA090-120A, 120CBAYISLT024A ................... Steel Spring Isolators ..................................... TTA180B, TTA180C, TTA120-150BBAYISLT025A ................... Steel Spring Isolators ..................................... TTA240BBAYLOAM015A0 .............. Head Pressure Control – 575V ...................... TTA090-180AW, BW, CWBAYLOAM326A40 ........... Head Pressure Control – 230V ...................... TTA090A3BAYLOAM327A40 ........... Head Pressure Control – 230V ...................... TTA120A3, B3, 120C3, 150B3BAYLOAM329A240 ....... Head Pressure Control – 230V ...................... TTA180B3, C3BAYLOAM328A240 ......... Head Pressure Control – 230V ...................... TTA240B3BAYLOAM425A0 .............. Head Pressure Control – 460V ...................... TTA090A4BAYLOAM426A40 ........... Head Pressure Control – 460V ...................... TTA120A4, B4, 150B4, 120C4BAYLOAM428A240 ......... Head Pressure Control – 460V ...................... TTA180B4, C4BAYLOAM427A240 ......... Head Pressure Control – 460V ...................... TTA240B4BAYLOAM429Bqw ........... Low Ambient Fan Cycle Control .................... TTA090-240A,B,CBAYLOAMW22A0 ............. Head Pressure Control – 575V ...................... TTA120, 150, 240AW, BW, CWBAYRLAY0023 ................ Time Delay Relay ........................................... TTA120-240B, TTA120-180C, TTA090-120ABAYSTAT033A .................. Outdoor Thermostat 45°F to -10°F ................ TTA090-120A, TTA120-240B, TTA120-180C

Table SC-15-B — Comfort ControlsModelNumber Description Used With

BAY28X1825 .................... 1-Stage Htg/Clg .............................................. TTA090-120ABAY28X1835 .................... 2-Stage Htg/Clg .............................................. TTA090-120A, 120-240B, 120-180CBAY28X1865 .................... 2-Stage Clg ..................................................... TTA090-120A, 120-240B, 120-180CBAY28X1846 .................... Subbase (Automatic/Manual Changeover) ..... BAY28X183BAY28X1857 .................... Subbase (Manual Changeover) ...................... BAY28X182, 183BAY28X1876 ..................... Subbase (Automatic Changeover) ................. BAY28X182, 183, 186BAY28X1903 .................... Locking Thermostat Cover ............................. All Room ThermostatsBAYBASE006A0 ............... Subbase 2-Stage Htg/Clg ............................... BAYSTAT040B with TTA090-120A,120-240B or 120-180CBAYBASE008A .................. Subbase 1-Stage Htg/Clg ............................... BAYSTAT040B with TTA090-120ABAYSENS033A .................. Remote Wall Sensor ....................................... BAYSTAT040BBAYSENS034A0 ............... Duct Temperature Sensor ............................... BAYSTAT040BBAYSTAT040B80 .............. Programmable Thermostat ............................. BAYBASE006A or BAYBASE008ATAYSENS100A .................. Outdoor Temp. Sensor (With Case) ............... TAYSTAT300C,302C,375TAYSTAT300C .................. XT 300C Prog., 7Day, A/M,1Htg/1Clg ............ All Cooling ModelsTAYSTAT302C .................. XT 302C Prog., 7Day, A/M,2Htg/2Clg ............ All Cooling ModelsTCONT200AN11AA ........... Electronic 1-Stage Htg/Clg ............................. TTA090A,120A1 Condensing unit must be on same level as or below Air Handler. Contact Application Engineer, Clarksville, before using any other configuration. (See Installers Guide).2 Quantity: 2 required on TTA180B, C; TTA240B.3 Do not use with programmable thermostats or ReliaTel™ model.4 Kits mount to the outdoor unit and operate by sensing liquid.5 Requires Subbase.6 Requires BAY24X042 relay kit when used with electric heat.7 Specifically designed for electric heat applications (instant on fan).8 Requires BAYBASE006A or BAYBASE008A.9 Activated on Power On.0 Option is compatible for units with ReliaTel™ Controls.q Option is compatible for units with electric mechanical controls only.w Kit mounts external to the outdoor unit and operates by sensing ambient and liquid line temperatures.

Split System CoolingThree Phase – 7½ through 20 Tons

Page 34: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

SC-16For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Effective 1/1/06

Table SC-16-A — Sensors for use with ReliaTel™ units.Model Mfg. ShippingNumber Description Used With Plant Weight

BAYSENS006B Single Setpoint Manual TTA090A_OR, OU, OT, OW- CK/001 1Changeover Zone Sensor TTA240B_OR, OU, OT, OW

BAYSENS008B Dual Setpoint Manual or Auto TTA090A_OR, OU, OT, OW- CK/001 1Changeover Zone Sensor TTA240B_OR, OU, OT, OW

BAYSENS010B Dual Setpoint Manual or Auto TTA090A_OR, OU, OT, OW- CK/001 1Changeover Zone Sensor with TTA240B_OR, OU, OT, OWSystem Function Lights

BAYSENS013C Zone Sensor w/ Timed TTA090A_OR, OU, OT, OW- CK/001 1Override & Cancel TTA240B_OR, OU, OT, OW

BAYSENS014C Zone Sensor w/ Setpoint TTA090A_OR, OU, OT, OW- CK/001 1Timed Override and Cancel TTA240B_OR, OU, OT, OW

BAYSENS017B Wall Mounted Zone Sensor for TTA090A_OR, OU, OT, OW- CK/001 1Remote Sensing TTA240B_OR, OU, OT, OW

BAYSENS019C Programmable Zone sensor TTA090A_OR, OU, OT, OW- CK/001 1NSB Panel TTA240B_OR, OU, OT, OW

BAYSENS032A Remote Wall Sensor TTA090A_OR, OU, OT, OW- CK/001 1for use with BAYSENS035A TTA240B_OR, OU, OT, OW

BAYSENS033A Remote Wall Sensor TTA090A-TTA240B CK/001 1for use with BAYSENS040A

BAYSENS034A Remote Duct Sensor TTA090A-TTA240B CK/001 1for use with BAYSTAT040B

BAYSENS035A Digital Zone Sensor with TTA090A_OR,OU,OT,OW- CK/001 1LCD Display TTA240B_OR,OU,OT,OW

Table SC-16-B — ControlsBAYICSI003A Trane Communication Interface (TCI) TTA090_OR,OT- CK/001 1

TTA240_OR,OTBAYLTCI002B LonTalk Communication Interface (LCI) TTA090_OR,OT- CK/001 1

TTA240_OR,OT

Split System CoolingThree Phase – 7½ through 20 Tons

Page 35: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

SC-17For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Effective 1/1/06

7 ½ - 20 Tons withReliaTel™ ControlsTTA090-120, TTA120-240, TTA120-180CProtection/Operation Timings and Features

Anti Short Cycle Timer (ASCT) Function — Provides a three (3)minute minimum “ON” time and a three (3) minute minimum “OFF” timefor compressors, enhances compressor reliability by ensuring proper oilreturn. Standard

Built In Fan Delay Relay (FDR) Function — Provides custom indoorfan timing sequences for the different types of equipment, enhancingefficiency and reliability. Standard

Built In Night Set Back and Unoccupied Functions1 — When usinga standard dual setpoint/auto change over Zone Sensor Module (ZSM),this function is enabled by applying a short across terminal J6-11 andJ6-12. Sets cooling setpoint up a minimum of 7°F, sets heating setpointback a minimum of 7°F, and forces fan operation to automatic.(requires time clock accessory or field supplied/installed switch orcontacts).

Built In “TEST” Mode — Aids in quick verification of systemand control operation, exercises both hardware and software(no special tools required). Standard

Built In Unoccupied Mode1 — When using a standard singlesetpoint/manual change over Zone Sensor Module (ZSM), this functionis enabled by applying a short across terminal J6-11 and J6-12. Forcesfan operation to automatic. (requires time clock accessory or fieldsupplied/installed switch or contacts.)

Direct Digital Control (DDC)1 — Proportional Integral (PI) control.Proportional – sets corrective action proportional to deviationfrom setpoint. Integral – fine tunes the rate of corrective actionproportional to the error (results in superior space temperature control).Standard

Increased Reliability — Fewer components (moving electro-mechanical parts), less likelihood of equipment down time orfailure. Standard

Integral Electric Heat Staging1 — Stages electric heaters “OFF” and“ON”, eliminating the use of outdated sequencers. Standard

Intelligent Fallback1 — A built in Default Control provides adaptiveoperation, which allows the equipment to continueto operate, providing comfort in the event of certain component failures.Also, allows emergency operation without a Zone Sensor Module(ZSM). Standard

Low Ambient Start Timer (LAST) Function — Bypasses lowpressure control when a compressor starts, eliminating nuisancecompressor lock outs. Standard

Lower Installation Cost — Using a standard Zone Sensor Module(ZSM), control voltage wiring may be run up to five (5) times furtherthan any electromechanical system, with no increase in wire gauge.Example: Electromechanical System –30 feet maximum using 22 gauge wire. Micro Control System – 150feet using 22 gauge wire. Standard

On Board Diagnostics1 — Assist with equipment troubleshooting, ifa problem occurrence should take place. Standard

Remote Sensing1 — All standard Zone Sensor Modules(ZSMs) have remote sensing capabilities, typically achieved by usingan expensive program-mable thermostat and remote sensor withelectromechanical equipment. Accessory (requires use of remotesensor).

Space Temperature Averaging1 — All standard Zone SensorModules (ZSMs) have space temperature averaging capabilities,typically achieved by using an expensive programmable thermostatand minimum of four (4) remote sensors with electromechanicalequipment. Averaging with ReliaTel™ can be achieved with two(2) sensors.

Time Delay Relay (TDR) Function — Provides an incrementalstaging delay between compressors, minimizes equipment currentinrush and consumption by keeping compressors from startingsimultaneously. Standard

Low Pressure and High Pressure Compressor Lockout — 3 tripswill lockout control.

1 Denotes features lost from utilizing standard conventional stat.

Page 36: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

SC-18For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Effective 1/1/06

7 ½ - 20 Tons with ReliaTel™Micro ControlOperation With A Thermostat

• Direct Digital Control (DDC) –Proportional Integral (PI) control is lost,equipment is controlled by a thermostator generic building automation systemdevice.

• Intelligent Fall back is lost, if a failureoccurs in the device controlling theequipment, operation will cease.

• Installation is more costly, with theaddition of a thermostat or genericcontrol, the control wiring size must beincreased.

• Remote Sensing capabilities are lost,unless generic control being applied canaccomplish this.

• Space Temperature Averagingcapabilities are lost, unless genericcontrol being applied can accomplishthis.

• Built In Night Set Back and Unoccu-pied functions are lost, unlessgeneric control being applied canaccomplish this.

• Built In Unoccupied Mode is lost,unless generic control being appliedcan accomplish this.

When the ReliaTel™ RTRM Thermostat Interface is used, equipment operationdiffers significantly. The basic equipment protection features remain intact, and thefollowing features and benefits are lost:

Page 37: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

SH-1 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Table SH-1-A — XL19i Weathertron® Split System Heat Pump — Single PhaseNom. Cap. Uncrated Shipping Line Size

Model Power Cooling Metering Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Device H W D (lbs.) Rating MCA* Fuse* Gas Liq.

2TWZ9030B1000A 200/230/1/60 30,000 TXV-NB 50 37 34 443 74 19 30 7/8 3/82TWZ9036B1000A 200/230/1/60 36,000 TXV-NB 50 37 34 440 74 22 36 7/8 3/82TWZ9048B1000A 200/230/1/60 48,000 TXV-NB 50 37 34 448 74 25 40 11/8 3/82TWZ9060B1000A 200/230/1/60 60,000 TXV-NB 50 37 34 455 74 37 60 11/8 3/8Note: Because of limited capabilities, please refer to product data for approved combinations.

Table SH-1-B — XL16i Weathertron® Split System Heat Pump — Single PhaseNom. Cap. Uncrated Shipping Line Size

Model Power Cooling Metering Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Device H W D (lbs.) Rating MCA* Fuse* Gas Liq.

4TWX6024B1000A 230/1/60 24,000 TXV-NB 44 33 30 260 72 12 20 5/8 5/16

4TWX6036B1000A 230/1/60 36,000 TXV-NB 46 37 34 305 71 24 40 3/4 3/84TWX6048B1000A 230/1/60 48,000 TXV-NB 50 37 34 320 74 29 50 7/8 3/84TWX6060B1000A 230/1/60 60,000 TXV-NB 50 37 34 362 74 35 60 7/8 3/8

Table SC-1-C — XL15i Split System Heat Pump — Single PhaseNom. Cap. Required Uncrated Shipping Line Size

Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.

2TWX5024A1000A 208/230/1/60 24,000 TXV-NB 42 37 34 273 74 14 20 3/4 5/16

2TWX5030A1000A 208/230/1/60 30,000 TXV-NB 46 37 34 290 71 20 30 3/4 5/16

2TWX5036A1000A 208/230/1/60 36,000 TXV-NB 50 37 34 304 74 20 30 7/8 3/82TWX5042A1000A 208/230/1/60 42,000 TXV-NB 50 37 34 314 72 23 35 7/8 3/82TWX5048A1000A 208/230/1/60 48,000 TXV-NB 50 37 34 342 74 26 40 11/8 3/8

Table SH-1-D — XL14i Split System Heat Pump — Single PhaseNom. Cap. Required Uncrated Shipping Line Size

Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.

2TWX4018B1000A 200/230/1/60 18,000 TXV-NB 40 33 30 242 71 8 15 5/8 1/42TWX4024B1000A 200/230/1/60 24,000 TXV-NB 44 33 30 256 74 11 15 3/4 5/16

2TWX4030B1000A 208/230/1/60 30,000 TXV-NB 42 37 34 275 73 18 30 3/4 5/16

2TWX4036B1000A 208/230/1/60 36,000 TXV-NB 46 37 34 294 74 21 35 7/8 3/82TWX4042B1000A 208/230/1/60 42,000 TXV-NB 50 37 34 309 74 24 40 7/8 3/82TWX4048B1000A 208/230/1/60 48,000 TXV-NB 50 37 34 313 74 28 45 11/8 3/82TWX4060B1000A 208/230/1/60 60,000 TXV-NB 50 37 34 340 74 34 50 11/8 3/8

Table SH-1-E — XL14i Split System Heat Pump — Single PhaseNom. Cap. Required Uncrated Shipping Line Size

Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.

4TWX4018B1000A 200/230/1/60 18,000 TXV-NB 40 33 30 224 74 10 15 1/2 1/44TWX4024B1000A 200/230/1/60 24,000 TXV-NB 48 33 30 239 74 13 20 5/8 5/16

4TWX4030B1000A 208/230/1/60 30,000 TXV-NB 48 33 30 242 71 20 30 3/4 5/16

4TWX4036B1000A 208/230/1/60 36,000 TXV-NB 46 37 34 259 72 21 35 3/4 3/84TWX4042B1000A 208/230/1/60 42,000 TXV-NB 50 37 34 274 74 25 40 3/4 3/84TWX4048B1000A 208/230/1/60 48,000 TXV-NB 50 37 34 280 74 30 50 7/8 3/84TWX4060B1000A 208/230/1/60 60,000 TXV-NB 50 37 34 318 74 36 60 7/8 3/8* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.** Rated in accordance with ARI Standard 270, section 5.3.6.

Split System Heat PumpsSingle Phase – 1½ through 5 Tons

XL19i

XL14i

XL14i

XL16i

XL15i

Page 38: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

SH-2Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Split System Heat PumpsSingle Phase – 1½ through 5 Tons

XL19i XL16i XL15i XL14i XL14iTable SH-2-A — Features (2TWZ9) (4TWX6) (2TWX5) (2TWX4) (4TWX4)• SEER’s up to .......................................................................................................... 17.90 17.00 16.50 15.00 15.00• HSPF’s up to .......................................................................................................... 8.8 9.2 9.0 9.0 9.0• Climatuff™ compressor ........................................................................................ 2 1 - staged ✔ ✔ ✔• Comfort”R”™ mode approved ............................................................................. ✔ ✔ ✔ ✔ ✔• DuraTuff™ base, fast complete drain, weatherproof ............................................. ✔ ✔ ✔ ✔ ✔

• Quick-Sess™ cabinet, service access & .............................................................. ✔ ✔ ✔ ✔ ✔ refrigerant connections with full coil protection

• Spine Fin™ coil ..................................................................................................... ✔ ✔ ✔ ✔ ✔

• Weatherguard™ II top .......................................................................................... ✔ ✔ ✔ ✔ ✔• Compressor sound enclosure ................................................................................ ✔ ✔ ✔ ✔ ✔• Compressor sump heat - factory installed .............................................................. 2½-5 5 2-4 1½-2 & 3½-5 1½-2• Factory supplied charge ......................................................................................... R-22 R-410A R-22 R-22 R-410A• Glossy corrosion resistant finish ............................................................................ ✔ ✔ ✔ ✔ ✔• High pressure switch .............................................................................................. — ✔ — — ✔

• Internal high / low pressure & temperature protection ............................................ ✔ ✔ ✔ ✔ ✔• Liquid line filter drier - factory installed ................................................................... ✔ ✔ ✔ ✔ ✔• Quick start kit - factory installed ............................................................................. 2½-5 5 — 1½-2 & 5 1½-2 & 5• Seacoast shield - factory installed .......................................................................... ✔ ✔ ✔ ✔ ✔• Tarpaulin gray cabinet ............................................................................................ ✔ ✔ ✔ ✔ ✔• 10-year limited warranty on compressor, outdoor coil & parts .............................. ✔ ✔ ✔ ✔ ✔

(Residential)• Extended warranties available ............................................................................... ✔ ✔ ✔ ✔ ✔

Table SH-2-B — Optional AccessoriesAY28X079 .............. Evaporator defrost control kit ..................................................... ✔ ✔ ✔ ✔ ✔BAYCCHT301 ........ Crank Case Heater Kit (Scroll Compressors) ............................ — 2-4 — 2½-3 2½-5BAYECMT001 ........ Extreme Condition Mounting Kit ................................................ ✔ ✔ ✔ ✔ ✔

BAYISLT101 .......... Rubber Isolators ........................................................................ ✔ ✔ ✔ ✔ ✔BAYKSKT260 ........ Quick start kit (21/2 - 4 ton) (Scroll Compressors) ..................... — 2-4 2-4 2½-4 2½-4BAYLEGS002 ........ Snow Legs - Base and Cap 6" High (Black) .............................. ✔ ✔ ✔ ✔ ✔

BAYLEGS003 ........ 4" Extension (Black) .................................................................. ✔ ✔ ✔ ✔ ✔

TAYASCT501A12 . Anti-Short Cycle Timer .............................................................. ✔ ✔ ✔ ✔ ✔

Comfort Controls — See Comfort Controls/Zone Sensors Section1 Do not use with programmable thermostats.2 Activated on Power Off.

Page 39: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

SH-3 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Table SH-3-A — XR14 Split System Heat Pump — Single PhaseNom. Cap. Required Uncrated Shipping Line Size

Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.

4TWR4018A1000A 200-230/1/60 18,000 TXV-NB 37 33 30 236 76 10 15 1/2 1/44TWR4024A1000A 200-230/1/60 24,000 TXV-NB 41 33 30 251 74 13 20 5/8 5/16

4TWR4030A1000A 208-230/1/60 30,000 TXV-NB 41 33 30 253 74 20 30 3/4 5/16

4TWR4036A1000A 208-230/1/60 36,000 TXV-NB 37 37 34 276 77 21 35 3/4 3/84TWR4042A1000A 208-230/1/60 42,000 TXV-NB 41 37 34 290 77 25 40 3/4 3/84TWR4048A1000A 208-230/1/60 48,000 TXV-NB 41 37 34 297 76 30 50 7/8 3/84TWR4060A1000A 208-230/1/60 60,000 TXV-NB 41 37 34 335 79 36 60 7/8 3/8

Table SH-3-B — XR14 Split System Heat Pump — Single PhaseNom. Cap. Required Uncrated Shipping Line Size

Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.

2TWR4018A1000A 200-230/1/60 18,000 TXV-NB 33 33 30 229 75 8 15 5/8 1/42TWR4024A1000A 200-230/1/60 24,000 TXV-NB 37 33 30 242 76 11 15 3/4 5/16

2TWR4030A1000A 208-230/1/60 30,000 TXV-NB 33 37 34 254 76 18 30 3/4 5/16

2TWR4036A1000A 208-230/1/60 36,000 TXV-NB 37 37 34 273 78 21 35 7/8 3/82TWR4042A1000A 208-230/1/60 42,000 TXV-NB 41 37 34 286 77 24 40 7/8 3/82TWR4048A1000A 208-230/1/60 48,000 TXV-NB 41 37 34 291 77 28 45 1 1/8 3/82TWR4060A1000A 208-230/1/60 60,000 TXV-NB 41 37 34 315 76 34 50 1 1/8 3/8

Table SH-3-C — XR13 Weathertron® Split System Heat Pump — Single PhaseNom. Cap. Required Uncrated Shipping Line Size

Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.

2TWR3018A1000A 200-230/1/60 18,000 TXV-NB 33 29 26 202 73 8 15 5/8 1/42TWR3024A1000A 200-230/1/60 24,000 TXV-NB 33 29 26 205 76 12 20 3/4 5/16

2TWR3030A1000A 200-230/1/60 30,000 TXV-NB 37 33 30 242 76 13 20 3/4 5/16

2TWR3036A1000A 200-230/1/60 36,000 TXV-NB 37 37 34 292 76 19 30 7/8 3/82TWR3042A1000A 200-230/1/60 42,000 TXV-NB 41 37 34 309 78 21 35 7/8 3/82TWR3048A1000A 200-230/1/60 48,000 TXV-NB 41 37 34 315 76 25 40 1 1/8 3/82TWR3060A1000A 208-230/1/60 60,000 TXV-NB 41 37 34 321 73 32 50 1 1/8 3/8

* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.** Rated in accordance with ARI Standard 270, section 5.3.6.

XR14

XR14

XR13

Split System Heat PumpsSingle Phase – 1½ through 5 Tons

Page 40: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

SH-4Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

XR14 XR14 XR13Table SH-4-A — Features (4TWR4) (2TWR4) (2TWR3)• SEER’s up to ......................................................................................................................................................... 14.00 14.00 14.00• HSPF’s up to ......................................................................................................................................................... 9.0 9.0 8.5• Climatuff™ compressor ....................................................................................................................................... ✔ ✔ ✔• Comfort”R”™ mode approved ............................................................................................................................ ✔ ✔ ✔

• DuraTuff™ base, fast complete drain, weatherproof ............................................................................................ ✔ ✔ ✔• Quick-Sess™ cabinet, service access & refrigerant connections with full coil protection .................................... ✔ ✔ ✔• Spine Fin™ coil .................................................................................................................................................... ✔ ✔ ✔

• Compressor sound enclosure ............................................................................................................................... ✔ ✔ ✔• Compressor sump heat - factory installed ............................................................................................................. 1½-5 1½-5 1½-5• Factory supplied charge ........................................................................................................................................ R-410A R-22 R-22• Glossy corrosion resistant finish ........................................................................................................................... ✔ ✔ ✔• High pressure switch ............................................................................................................................................. ✔ — —• Low pressure switch ............................................................................................................................................. — — ✔

• Internal high / low pressure & temperature protection ........................................................................................... ✔ ✔ ✔• Liquid line filter drier - factory installed .................................................................................................................. ✔ ✔ ✔• Quick start kit - factory installed ............................................................................................................................ 1½-2,5 1½-2,5 1½-5• Tarpaulin gray cabinet ........................................................................................................................................... ✔ ✔ ✔• 10-year limited warranty on compressor, outdoor coil & 5 years on parts (Residential) ........................................ ✔ ✔ ✔• Extended warranties available .............................................................................................................................. ✔ ✔ ✔

Table SH-4-B — Optional AccessoriesAY28X079 .............. Evap. Defrost Control Kit .......................................................................................................... ✔ ✔ ✔BAYECMT001 ........ Extreme Condition Mounting Kit ............................................................................................... ✔ ✔ ✔

BAYISLT101 .......... Rubber Isolators ....................................................................................................................... ✔ ✔ ✔BAYKSKT260 ........ Start Kit (Scroll Compressors) .................................................................................................. 2½-4 2½-4 —BAYLEGS002 ........ Snow Legs - Base and Cap 6" High (Black) ............................................................................. ✔ ✔ ✔

BAYLEGS003 ........ 4" Extension (Black) ................................................................................................................. ✔ ✔ ✔BAYLOAM103 ........ Low Ambient Kit ....................................................................................................................... — ✔ ✔BAYSEAC001 ........ Seacoast Kit ............................................................................................................................. ✔ ✔ ✔

TAYASCT501A12 . Anti-Short Cycle Timer ............................................................................................................. ✔ ✔ ✔

Comfort Controls — See Comfort Controls/Zone Sensors Section1 Do not use with programmable thermostats.2 Activated on Power Off.

Split System Heat PumpsSingle Phase – 1½ through 5 Tons

Page 41: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

SH-5 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

PHASED OUT

PHASED OUT

PHASED OUT

Split System Heat PumpsSingle Phase – 1½ through 5 Tons

XR12

XR11

XR12

Table SH-5-A — XR12 Split System Heat Pump — Single PhaseNom. Cap. Required Uncrated Shipping Line Size

Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.

4TWR2018A1000A 200/230/1/60 18,000 .047 33 33 30 221 77 10 15 1/2 1/44TWR2024A1000A 200/230/1/60 24,000 .053 33 33 30 225 78 14 20 5/8 5/16

4TWR2030A1000A 208/230/1/60 30,000 .059 33 33 30 234 74 20 30 3/4 5/16

4TWR2036A1000A 208/230/1/60 36,000 .063 41 33 30 257 77 21 35 3/4 3/84TWR2042A1000A 208/230/1/60 42,000 .069 41 33 30 262 79 26 45 3/4 3/84TWR2048A1000A 208/230/1/60 48,000 .075 33 37 34 271 79 30 50 7/8 3/84TWR2060A1000A 208/230/1/60 60,000 11111 41 37 34 302 81 36 60 7/8 3/8

Table SH-5-B — XR12 Split System Heat Pump — Single PhaseNom. Cap. Required Uncrated Shipping Line Size

Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.

2TWR2018A1000A 200/230/1/60 18,000 .049 26 29 26 176 79 10 15 5/8 1/42TWR2024A1000A 200/230/1/60 24,000 .059 29 29 26 191 78 13 20 3/4 5/16

2TWR2030B1000A 208/230/1/60 30,000 .065 29 29 26 187 99 18 30 3/4 5/16

2TWR2036A1000A 208/230/1/60 36,000 .071 33 33 30 233 77 21 35 7/8 3/82TWR2042A1000A 208/230/1/60 42,000 .077 33 33 30 229 79 24 40 7/8 3/82TWR2048A1000B 208/230/1/60 48,000 .086 37 33 30 256 99 26 45 11/8 3/82TWR2060A1000A 208/230/1/60 60,000 11111 41 37 34 316 80 37 60 11/8 3/8

Table SH-5-C — XR11 Weathertron® Split System Heat Pump — Single PhaseNom. Cap. Required Uncrated Shipping Line Size

Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.

2TWR1018A1000A 200/230/1/60 18,000 0.049 26 29 26 168 77 10 15 5/8 1/42TWR1024A1000A 200/230/1/60 24,000 0.057 26 29 26 176 77 15 25 3/4 5/16

2TWR1030A1000A 200/230/1/60 30,000 0.069 29 29 26 187 79 18 30 3/4 5/16

2TWR1036A1000A 200/230/1/60 36,000 0.069 29 29 26 190 79 21 35 7/8 3/82TWR1042A1000A 200/230/1/60 42,000 0.077 33 33 30 253 79 23 40 7/8 3/82TWR1048A1000A 200/230/1/60 48,000 0.083 33 33 30 259 80 30 50 11/8 3/82TWR1060A1000A 200/230/1/60 60,000 11111 33 37 34 292 81 34 50 11/8 3/8

1 Indoor Metering device TXV only.* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.** Rated in accordance with ARI Standard 270, section 5.3.6.

Page 42: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

SH-6Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

PH

AS

ED

OU

T

PH

AS

ED

OU

T

PH

AS

ED

OU

T

Split System Heat PumpsSingle Phase – 1½ through 5 Tons

XR12 XR12 XR11Table SH-6-A — Features (4TWR2) (2TWR2) (2TWR1)• SEER’s up to .................................................................................................................................................................. 13.00 13.00 11.50• HSPF’s up to .................................................................................................................................................................. 9.25 10.15 8.50• Climatuff™ compressor ................................................................................................................................................ ✔ ✔ ✔• Comfort”R”™ mode approved ...................................................................................................................................... ✔ ✔ ✔• DuraTuff™ base, fast complete drain, weatherproof ...................................................................................................... ✔ ✔ ✔• Quick-Sess™ cabinet, service access & refrigerant connections with full coil protection ............................................... ✔ ✔ ✔• Spine Fin™ coil ............................................................................................................................................................. ✔ ✔ ✔• Factory installed start kit ................................................................................................................................................. 1-2 & 5 1-2 —• Factory supplied charge ................................................................................................................................................. R-410A R-22 R-22• Glossy corrosion resistant finish ..................................................................................................................................... ✔ ✔ ✔• High pressure switch ...................................................................................................................................................... ✔ — —• Internal high / low pressure & temperature protection ..................................................................................................... ✔ ✔ ✔• Liquid line filter drier - factory installed ............................................................................................................................ ✔ ✔ ✔• Tarpaulin gray cabinet .................................................................................................................................................... ✔ ✔ ✔• 10-year limited warranty on compressor, outdoor coil & 5 years on parts (Residential) .................................................. ✔ ✔ ✔

• Extended warranties available ........................................................................................................................................ ✔ ✔ ✔

Table SH-6-B — Optional AccessoriesAY28X079 ............... Evap. Defrost Control Kit .................................................................................................................. ✔ ✔ ✔BAY24X045 ............. ID Fan Delay Relay Kit ..................................................................................................................... ✔ ✔ ✔BAYCCHT300 ......... Crankcase Heater Kit (Reciprocating Compressors) ........................................................................ 1½-2 1½-2 1½-5BAYCCHT301 ......... Crankcase Heater Kit (Scroll Compressors) ..................................................................................... 2½-5 2½-5 —BAYECMT001 ......... Extreme Condition Mounting Kit ....................................................................................................... ✔ ✔ ✔BAYISLT101 ............ Rubber Isolators ............................................................................................................................... ✔ ✔ ✔BAYKSKT257 .......... Start Kit (Reciprocating Compressors) ............................................................................................. — — 2½-5BAYKSKT260 .......... Start Kit (Scroll Compressors) .......................................................................................................... 2½-4 2½-5 —BAYLEGS002 .......... Snow Legs - Base and Cap 6" High (Black) ..................................................................................... ✔ ✔ ✔BAYLEGS003 .......... 4" Extension (Black) ......................................................................................................................... ✔ ✔ ✔BAYLOAM103 ......... Low Ambient Kit ............................................................................................................................... — ✔ 2½-5BAYLOAM104 ......... Low Ambient Kit with Start Kit .......................................................................................................... — — 1½-2BAYSDEN001 ......... Single Cylinder Compressor Enclosures .......................................................................................... — — 1½-2BAYSDEN003 ......... Small Scroll Compressor Enclosures ................................................................................................ — 2½-4 —BAYSEAC001 ......... Seacoast Kit ..................................................................................................................................... ✔ ✔ ✔

Table SH-6-C — Comfort ControlsTAYASCT501A12 .. Anti-Short Cycle Timer ..................................................................................................................... ✔ ✔ ✔TAYSENS100A ....... Outdoor Temp. Sensor (with case) ................................................................................................... ✔ ✔ ✔TAYSTAT241 .......... Manual 2 Htg/1 Clg ........................................................................................................................... ✔ ✔ ✔TAYSTAT250B ........ Outdoor Thermostat ......................................................................................................................... ✔ ✔ ✔TAYSTAT300C ........ XT300C Prog., 7 Day, A/M,1Htg/1Clg .............................................................................................. ✔ ✔ ✔TAYSTAT302C ........ XT302C Prog., 7 Day, A/M,2Htg/2Clg .............................................................................................. ✔ ✔ ✔TAYSTAT340 .......... Prog., 5/2 Day, Manual, 1 Htg/1 Clg ................................................................................................. ✔ ✔ ✔TAYSTAT350 .......... Prog., 5/2 Day, Manual, 2 (Gas) Htg/1Clg ........................................................................................ ✔ ✔ ✔TAYSTAT370 .......... Electronic, 1Htg (Gas) /1 Clg ( Non Prog.) ........................................................................................ ✔ ✔ ✔TAYSTAT371 .......... Electronic, 1Htg (Elec.) /1 Clg ( Non Prog.) ...................................................................................... ✔ ✔ ✔TAYSTAT375 .......... Electronic, 2Htg (Gas/Elec.) 2 Clg (Non Prog.) Field Selectable ....................................................... ✔ ✔ ✔TAYSTAT380 .......... Electronic, 2 Htg (Gas)/ 1 Clg (Non Prog.) ........................................................................................ ✔ ✔ ✔TCONT200A ............ Electronic, 1Htg/1Clg (Gas/Elec./Oil) ................................................................................................ ✔ ✔ ✔TCONT401A ............ 2Heat/1Clg (Heat Pump/A/C) ........................................................................................................... ✔ ✔ ✔TCONT402A ............ 3Heat/2Clg (Heat Pump/A/C) ........................................................................................................... ✔ ✔ ✔TCONT600A ............ 1Heat/1Clg (Heat Pump/A/C) ........................................................................................................... ✔ ✔ ✔TCONT602A ............ 2Heat/1Clg (Heat Pump/A/C) ........................................................................................................... ✔ ✔ ✔TCONT800A ............ 2Heat/1Clg (Heat Pump/A/C) ........................................................................................................... ✔ ✔ ✔TCONT802A ............ 3Heat/2Clg (Heat Pump/A/C) ........................................................................................................... ✔ ✔ ✔TCONT803A ............ 3Heat/2Clg (Heat Pump/A/C) w/Humidity Control ............................................................................. ✔ ✔ ✔1 Do not use with programmable thermostats.2 Activated on Power Off.

Page 43: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

SH-7 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

PHASED OUT

PHASED OUT

XB10

XB12

Split System Heat PumpsSingle Phase – 1½ through 5 Tons

XB13

Table SH-7-A — XB13 Weathertron® Split System Heat Pump — Single PhaseNom. Cap. Required Uncrated Shipping Line Size

Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.

2TWB3018A1000A 200-230/1/60 17,000 TXV-NB 33 29 26 202 74 8 15 5/8 1/42TWB3024A1000A 200-230/1/60 23,000 TXV-NB 33 29 26 205 79 12 20 3/4 5/16

2TWB3030A1000A 200-230/1/60 28,500 TXV-NB 37 33 30 240 79 13 20 3/4 5/16

2TWB3036A1000A 200-230/1/60 34,500 TXV-NB 37 37 34 291 79 19 30 7/8 3/82TWB3042A1000A 200-230/1/60 40,500 TXV-NB 41 37 34 308 80 21 35 7/8 3/82TWB3048A1000A 200-230/1/60 46,500 TXV-NB 41 37 34 312 78 25 40 1 1/8 3/82TWB3060A1000A 208-230/1/60 58,500 TXV-NB 41 37 34 318 79 32 50 1 1/8 3/8

Table SH-7-B — XB12 Weathertron® Split System Heat Pump — Single PhaseNom. Cap. Required Uncrated Shipping Line Size

Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.

2TWB2018A1000A 200/230/1/60 18,000 .049 26 29 26 176 81 10 15 5/8 1/42TWB2024A1000A 200/230/1/60 24,000 .059 29 29 26 191 82 13 20 3/4 5/16

2TWB2030A1000A 208/230/1/60 30,000 .065 29 29 26 187 79 18 30 3/4 5/16

2TWB2036A1000A 208/230/1/60 36,000 .071 33 33 30 233 77 21 35 7/8 3/82TWB2042A1000A 208/230/1/60 42,000 .077 33 33 30 229 79 24 40 7/8 3/82TWB2048A1000A 208/230/1/60 48,000 .086 37 33 30 256 79 26 45 11/8 3/82TWB2060A1000A 208/230/1/60 60,000 11111 41 37 34 316 80 37 60 11/8 3/8

Table SH-7-C— XB10 Weathertron® Split System Heat Pump — Single PhaseNom. Cap. Required Uncrated Shipping Line Size

Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.

2TWB0012A1000A 200/230/1/60 12,000 .047 26 29 26 169 79 10 15 5/8 1/42TWB0018A1000A 200/230/1/60 18,000 .049 26 29 26 169 79 10 15 5/8 1/42TWB0024A1000A 200/230/1/60 24,000 .057 26 29 26 177 79 15 25 3/4 5/16

2TWB0030A1000A 200/230/1/60 30,000 .067 29 29 26 187 81 17 25 3/4 5/16

2TWB0036A1000A 200/230/1/60 36,000 .067 29 29 26 189 81 20 30 7/8 3/82TWB0042A1000A 200/230/1/60 42,000 .075 33 33 30 247 79 23 40 7/8 3/82TWB0048A1000A 200/230/1/60 48,000 .083 33 33 30 255 80 26 40 11/8 3/82TWB0060A1000A 200/230/1/60 60,000 11111 33 37 34 291 81 34 50 11/8 3/8

1 Indoor Metering device TXV only.

Page 44: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

SH-8Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

PH

AS

ED

OU

T

PH

AS

ED

OU

T

PH

AS

ED

OU

T

Split System Heat PumpsSingle Phase – 1½ through 5 Tons

XB13 XB12 XB10Table SH-8-A — Features (2TWB3) (2TWB2) (2TWB0)• SEER’s up to ......................................................................................................................................................... 13.25 12.50 10.50• HSPF’s up to ......................................................................................................................................................... 8.0 9.10 8.15• Climatuff™ compressor ....................................................................................................................................... ✔ ✔ ✔• Comfort”R”™ mode approved ............................................................................................................................ ✔ ✔ ✔

• DuraTuff™ base, fast complete drain, weatherproof ............................................................................................ ✔ ✔ ✔• Quick-Sess™ cabinet, service access & refrigerant connections with full coil protection .................................... ✔ ✔ ✔• Spine Fin™ coil .................................................................................................................................................... ✔ ✔ ✔

• Compressor sound enclosure ............................................................................................................................... 3-4 4-5 4-5• Compressor sump heat - factory installed ............................................................................................................. 1½-5 1½-2,4-5 1½-5• Factory supplied charge ........................................................................................................................................ R-22 R-22 R-22• Glossy corrosion resistant finish ........................................................................................................................... ✔ ✔ ✔• Low pressure switch ............................................................................................................................................. ✔ — —• Internal high / low pressure & temperature protection ........................................................................................... ✔ ✔ ✔

• Liquid line filter drier - factory installed .................................................................................................................. ✔ ✔ ✔• PolySlate gray cabinet .......................................................................................................................................... ✔ ✔ ✔• Quick start kit - factory installed ............................................................................................................................ 1½-5 1½-2,5 —• 10-year limited warranty on compressor, outdoor coil & 5 years on parts (Residential) ........................................ ✔ ✔ ✔

• Extended warranties available .............................................................................................................................. ✔ ✔ ✔

Table SH-8-B — Optional AccessoriesAY28X079 .............. Evap. Defrost Control Kit .......................................................................................................... ✔ ✔ ✔

BAYCCHT301 ........ Crankcase Heater Kit (Scroll Compressors) ............................................................................. — 2½-3½ —BAYECMT001 ........ Extreme Condition Mounting Kit ............................................................................................... ✔ ✔ ✔BAYISLT101 .......... Rubber Isolators ....................................................................................................................... ✔ ✔ ✔BAYKSKT257 ........ Start Kit (Reciprocating Compressors) ..................................................................................... — — 1-5BAYKSKT260 ........ Start Kit (Scroll Compressors) .................................................................................................. — 2½-4 —BAYLEGS002 ........ Snow Legs - Base and Cap 6" High (Black) ............................................................................. ✔ ✔ ✔BAYLEGS003 ........ 4" Extension (Black) ................................................................................................................. ✔ ✔ ✔

BAYLOAM103 ........ Low Ambient Kit ....................................................................................................................... ✔ ✔ ✔BAYSDEN001 ........ Single Cylinder Compressor Enclosures .................................................................................. 1½-2 1-3 ?BAYSDEN002 ........ Two Cylinder Compressor Enclosures ..................................................................................... — 3½ ?BAYSDEN003 ........ Small Scroll Compressor Enclosures ....................................................................................... 2½ -— ?BAYSDEN004 ........ Large Scroll Compressor Enclosures ....................................................................................... 5 — ?BAYSEAC001 ........ Seacoast Kit ............................................................................................................................. ✔ ✔ ✔

Table SH-8-C — Comfort ControlsTAYASCT501A12 . Anti-Short Cycle Timer ............................................................................................................. ✔ ✔TAYSENS100A ...... Outdoor Temp. Sensor (with case) ........................................................................................... ✔ ✔TAYSTAT241 ......... Manual 2 Htg/1 Clg ................................................................................................................... ✔ ✔

TAYSTAT250B ...... Outdoor Thermostat ................................................................................................................. ✔ ✔TAYSTAT300C ...... XT300C Prog., 7 Day, A/M,1Htg/1Clg ...................................................................................... ✔ ✔TAYSTAT302C ...... XT302C Prog., 7 Day, A/M,2Htg/2Clg ...................................................................................... ✔ ✔

TAYSTAT340 ......... Prog., 5/2 Day, Manual, 1 Htg/1 Clg ......................................................................................... ✔ ✔TAYSTAT350 ......... Prog., 5/2 Day, Manual, 2 (Gas) Htg/1Clg ................................................................................ ✔ ✔TAYSTAT370 ......... Electronic, 1Htg (Gas) /1 Clg ( Non Prog.) ............................................................................... ✔ ✔

TAYSTAT371 ......... Electronic, 1Htg (Elec.) /1 Clg ( Non Prog.) .............................................................................. ✔ ✔TAYSTAT375 ......... Electronic, 2Htg (Gas/Elec.) 2 Clg (Non Prog.) Field Selectable .............................................. ✔ ✔TAYSTAT380 ......... Electronic, 2 Htg (Gas)/ 1 Clg (Non Prog.) ............................................................................... ✔ ✔

TCONT200A .......... Electronic, 1Htg/1Clg (Gas/Elec./Oil) ....................................................................................... ✔ ✔TCONT401A .......... 2Heat/1Clg (Heat Pump/A/C) ................................................................................................... ✔ ✔TCONT402A .......... 3Heat/2Clg (Heat Pump/A/C) ................................................................................................... ✔ ✔

TCONT600A .......... 1Heat/1Clg (Heat Pump/A/C) ................................................................................................... ✔ ✔TCONT602A .......... 2Heat/1Clg (Heat Pump/A/C) ................................................................................................... ✔ ✔TCONT800A .......... 2Heat/1Clg (Heat Pump/A/C) ................................................................................................... ✔ ✔

TCONT802A .......... 3Heat/2Clg (Heat Pump/A/C) ................................................................................................... ✔ ✔TCONT803A .......... 3Heat/2Clg (Heat Pump/A/C) w/Humidity Control .................................................................... ✔ ✔

1 Do not use with programmable thermostats.2 Activated on Power Off.

See

Com

fort

Con

trol

s/ Z

one

Sen

sors

Sec

tion

Page 45: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

SH-9 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

PHASED OUT

Split System Heat PumpsThree Phase – 2½ through 6 Tons

2TWA2

2TWA0

2TWA3

Table SH-9-A — Split System Heat Pump — Three PhaseNom. Cap. Required Uncrated Shipping Line Size

Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.

2TWA0030A3000A 200-230/3/60 30,000 .069 29 29 26 193 82 13 20 3/4 5/16

2TWA0036A3000A 200-230/3/60 36,000 .069 29 29 26 192 80 15 25 7/8 3/82TWA0042A3000A 200-230/3/60 42,000 .077 33 33 30 250 81 17 30 7/8 3/82TWA0048A3000A 200-230/3/60 48,000 .083 33 33 30 254 81 19 30 11/8 3/82TWA0060A3000A 200-230/3/60 60,000 11111 33 37 34 289 84 25 40 11/8 3/82TWA0072A3000A 200-230/3/60 72,000 11111 41 37 34 327 81 26 40 11/8 3/8

2TWA0030A4000A 460/3/60 30,000 .069 29 29 26 193 82 7 15 3/4 5/16

2TWA0036A4000A 460/3/60 36,000 .069 29 29 26 192 80 7 15 7/8 3/82TWA0042A4000A 460/3/60 42,000 .077 33 33 30 250 81 9 15 7/8 3/82TWA0048A4000A 460/3/60 48,000 .083 33 33 30 254 81 10 15 11/8 3/82TWA0060A4000A 460/3/60 60,000 11111 33 37 34 289 84 12 20 11/8 3/82TWA0072A4000A 460/3/60 72,000 11111 41 37 34 327 81 14 20 11/8 3/8

Table SH-9-B — Split System Heat Pump — Three PhaseNom. Cap. Required Uncrated Shipping Line Size

Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.

2TWA3030A3000A 200-230/3/60 30,000 TXV-NB 37 33 30 239 77 9 15 3/4 5/16

2TWA3036A3000A 200-230/3/60 36,000 TXV-NB 37 37 34 285 79 11 15 7/8 3/82TWA3042A3000A 200-230/3/60 42,000 TXV-NB 41 37 34 304 80 13 20 7/8 3/82TWA3048A3000A 200-230/3/60 48,000 TXV-NB 41 37 34 309 78 16 25 1 1/8 3/82TWA3060A3000A 200-230/3/60 60,000 TXV-NB 41 37 34 303 73 23 40 1 1/8 3/8

2TWA3030A4000A 460/3/60 30,000 TXV-NB 37 33 30 239 77 5 15 3/4 5/16

2TWA3036A4000A 460/3/60 36,000 TXV-NB 37 37 34 286 79 6 15 7/8 3/82TWA3042A4000A 460/3/60 42,000 TXV-NB 41 37 34 305 80 7 15 7/8 3/82TWA3048A4000A 460/3/60 48,000 TXV-NB 41 37 34 310 78 9 15 1 1/8 3/82TWA3060A4000A 460/3/60 60,000 TXV-NB 41 37 34 304 73 11 15 1 1/8 3/8

Table SH-9-C — Split System Heat Pump — Three PhaseNom. Cap. Required Uncrated Shipping Line Size

Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD ODNumber Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.

2TWA2030A3000A 200-230/3/60 30,000 .065 29 29 26 185 79 12 20 3/4 5/16

2TWA2036A3000A 200-230/3/60 36,000 .071 33 33 30 228 77 14 20 7/8 3/82TWA2042A3000A 208-230/3/60 42,000 .077 33 33 30 224 79 17 25 7/8 3/82TWA2048A3000A 208-230/3/60 48,000 .086 37 33 30 251 79 20 30 11/8 3/82TWA2060A3000A 208-230/3/60 60,000 11111 41 37 34 303 80 23 40 11/8 3/8

2TWA2030A4000A 460/3/60 30,000 .065 29 29 26 188 79 6 15 3/4 5/16

2TWA2036A4000A 460/3/60 36,000 .071 33 33 30 228 77 7 15 7/8 3/82TWA2042A4000A 460/3/60 42,000 .077 33 33 30 224 79 8 15 7/8 3/82TWA2048A4000A 460/3/60 48,000 .086 37 33 30 250 79 10 15 11/8 3/82TWA2060A4000A 460/3/60 60,000 11111 41 37 34 303 80 12 20 11/8 3/8

1 Indoor Metering device TXV only.* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.** Rated in accordance with ARI Standard 270, section 5.3.6.

Page 46: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

SH-10Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

PH

AS

ED

OU

TP

HA

SE

D O

UT

PH

AS

ED

OU

T

Split System Heat PumpsThree Phase – 2½ through 6 Tons

Table SH-10-A — Features 2TWA0 2TWA3 2TWA2• SEER’s up to ....................................................................................................................................................... 11.75 14.50 12.5• HSPF .................................................................................................................................................................. 8.2 8.8 9.75• Climatuff™ compressor ..................................................................................................................................... ✔ ✔ ✔• Comfort”R”™ mode approved .......................................................................................................................... ✔ ✔ ✔

• DuraTuff™ base, fast complete drain, weatherproof .......................................................................................... ✔ ✔ ✔• Quick-Sess™ cabinet, service access & refrigerant connections with full coil protection .................................. ✔ ✔ ✔• Spine Fin™ coil .................................................................................................................................................. ✔ ✔ ✔

• Compressor sump heat - factory installed ........................................................................................................... 2½-6 2½-5 2½-5• Factory supplied charge ...................................................................................................................................... R-22 R-22 R-22• Glossy corrosion resistant finish ......................................................................................................................... ✔ ✔ ✔

• Internal high / low pressure & temperature protection ......................................................................................... ✔ ✔ ✔• Liquid line filter drier - factory installed ................................................................................................................ ✔ ✔ ✔• Low pressure switch ........................................................................................................................................... ✔ ✔ ✔

• PolySlate gray cabinet ........................................................................................................................................ ✔ ✔ ✔• 5-year limited warranty on compressor, and 1 year on coil and parts (Commercial) ........................................... ✔ ✔ ✔• 5-year limited warranty on compressor, coil and 1 year on parts (Residential) ................................................... ✔ ✔ ✔

• Extended warranties available ............................................................................................................................ ✔ ✔ ✔

Table SH-10-B — Optional AccessoriesAY28X079 ...................... Evaporator Defrost Control ............................................................................................. ✔ ✔ ✔BAYECMT001 ................ Extreme Condition Mounting Kit ..................................................................................... ✔ ✔ ✔BAYISLT101 .................. Rubber Isolators ............................................................................................................. ✔ ✔ ✔

BAYLEGS002 ................ Snow Legs - Base and Cap 6" High (Black) ................................................................... ✔ ✔ ✔BAYLEGS003 ................ 4" Extension (Black) ....................................................................................................... ✔ ✔ ✔BAYLOAM103 ................ Electronic Head Pressure Control .................................................................................. ✔ ✔ ✔

BAYSDEN001 ................ Single Cylinder Compressor Enclosures ........................................................................ 2½-3 2½ —BAYSDEN002 ................ Two Cylinder Compressor Enclosures ........................................................................... 3½-5 3-4 —BAYSDEN003 ................ Small Scroll Compressor Enclosures ............................................................................. — — 2½-4BAYSDEN004 ................ Large Scroll Compressor Enclosures ............................................................................. 6 5 5BAYSEAC001 ................ Seacoast Kit ................................................................................................................... ✔ ✔ ✔TAYASCT501A12 ........ Anti-Short Cycle Timer ................................................................................................... ✔ ✔ ✔

Table SH-10-C — Comfort ControlsTAYSENS100A ............. Outdoor Temp. Sensor (with case) ................................................................................ ✔

TAYSTAT241 ................. Manual 2 Stg Htg/1 Clg .................................................................................................. ✔TAYSTAT250B .............. Outdoor Thermostat ....................................................................................................... ✔TAYSTAT300C ............. XT300C Prog.,7 Day,A/M,1Htg/1Clg .............................................................................. ✔

TAYSTAT340 ................. Prog., 5/2 Day, Manual, 1 Htg/1 Clg ............................................................................... ✔TAYSTAT350 ................. Prog., 5/2 Day, Manual, 2 (Gas) Htg/1 Clg ..................................................................... ✔TAYSTAT370 ................. Electronic, 1Htg(Gas)/1Clg(Non Prog.) .......................................................................... ✔

TAYSTAT371 ................. Electronic, 1Htg(Elec)/1Clg(Non Prog.) .......................................................................... ✔TAYSTAT380 ................. Electronic, 2 Htg (Gas) 1 Clg(Non Prog.) ....................................................................... ✔TCONT200A .................. Electronic, 1Htg/1Clg (Gas/Elec./Oil) ............................................................................. ✔

TCONT401A .................. 2Heat/1Clg (Heat Pump/A/C) ......................................................................................... ✔TCONT402A .................. 3Heat/2Clg (Heat Pump/A/C) ......................................................................................... ✔TCONT600A .................. 1Heat/1Clg (Heat Pump/A/C) ......................................................................................... ✔

TCONT602A .................. 2Heat/1Clg (Heat Pump/A/C) ......................................................................................... ✔TCONT800A .................. 2Heat/1Clg (Heat Pump/A/C) ......................................................................................... ✔TCONT802A .................. 3Heat/2Clg (Heat Pump/A/C) ......................................................................................... ✔

TCONT803A .................. 3Heat/2Clg (Heat Pump/A/C) w/Humidity Control .......................................................... ✔

1 Do not use with programmable thermostats2 Activated on Power Off.* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.

See

Com

fort

Con

trol

s/ Z

one

Sen

sors

Sec

tion

See

Com

fort

Con

trol

s/ Z

one

Sen

sors

Sec

tion

Page 47: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

SH-11 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Split System Heat PumpsThree Phase – 7½ through 20 Tons

Table SH-11-A— TWA Split System Heat Pump — Single CompressorFactory Nom. Cap. Uncrated Shipping Line Size

Model Installed Power Cooling Dimensions(in.) Mfg. Weight Sound Max OD ODNumber Option Supply (BTUH) H W L Plant (lbs.) Rating MCA Fuse Gas Liq.

TWA090A300F — 208-230/3/60 91,000 39 34 41 SPR 390 8.8 34.5 50 13/8 1/2TWA120A300F — 208-230/3/60 124,000 44 38 51 SPR 502 8.8 48.1 70 13/8 1/2

TWA090A400F — 460/3/60 91,000 39 34 41 SPR 390 8.8 18.1 25 13/8 1/2TWA120A400F — 460/3/60 124,000 44 38 51 SPR 502 8.8 23.3 35 13/8 1/2

TWA090AW00F — 575/3/60 91,000 39 34 41 SPR 390 8.8 14.5 25 13/8 1/2TWA120AW00F — 575/3/60 124,000 44 38 51 SPR 502 8.8 18.8 35 13/8 1/2

Table SH-11-B— TWA Split System Heat Pump — Dual CompressorFactory Nom. Cap. Uncrated Shipping Line Size

Model Installed Power Cooling Dimensions(in.) Mfg. Weight Sound Max OD ODNumber Option Supply (BTUH) H W L Plant (lbs.) Rating MCA Fuse Gas Liq.

TWA180B300F — 208-230/3/60 182,000 38 34 88 SPR 816 8.8 62.7 80 13/8 1/2TWA240B300F — 208-230/3/60 240,000 45 44 94 SPR 934 8.8 87.8 100 13/8 1/2

TWA180B400F — 460/3/60 182,000 38 34 88 SPR 816 8.8 32.9 45 13/8 1/2TWA240B400F — 460/3/60 240,000 45 44 94 SPR 934 8.8 42.5 50 13/8 1/2

TWA180BW00F — 575/3/60 182,000 38 34 88 SPR 816 8.8 26.3 35 13/8 1/2TWA240BW00F — 575/3/60 240,000 45 44 94 SPR 934 8.8 34.2 45 13/8 1/2

Table SH-11-A — Optional factory installed Black Epoxy Coil for corrosive resistance.Factory Nom. Cap. Uncrated Shipping Line Size

Model Installed Power Cooling Dimensions(in.) Mfg. Weight Sound Max OD ODNumber Option Supply (BTUH) H W L Plant (lbs.) Rating MCA Fuse Gas Liq.

TWA090A30SF Epoxy Coil 208-230/3/60 91,000 39 34 41 SPR 390 8.8 34.5 50 13/8 1/2TWA120A30SF Epoxy Coil 208-230/3/60 124,000 44 38 51 SPR 502 8.8 48.1 70 13/8 1/2

TWA090A40SF Epoxy Coil 460/3/60 91,000 39 34 41 SPR 390 8.8 18.1 25 13/8 1/2TWA120A40SF Epoxy Coil 460/3/60 124,000 44 38 51 SPR 502 8.8 23.3 35 13/8 1/2

TWA090AW0SF Epoxy Coil 575/3/60 91,000 39 34 41 SPR 390 8.8 14.5 20 13/8 1/2TWA120AW0SF Epoxy Coil 575/3/60 124,000 44 38 51 SPR 502 8.8 18.8 25 13/8 1/2

Table SH-11-B — Optional factory installed Black Epoxy Coil for corrosive resistance.Factory Nom. Cap. Uncrated Shipping Line Size

Model Installed Power Cooling Dimensions(in.) Mfg. Weight Sound Max OD ODNumber Option Supply (BTUH) H W L Plant (lbs.) Rating MCA Fuse Gas Liq.

TWA180B30SF Epoxy Coil 208-230/3/60 182,000 38 34 88 SPR 816 8.8 62.7 80 13/8 1/2TWA240B30SF Epoxy Coil 208-230/3/60 240,000 45 44 94 SPR 934 8.8 87.8 100 13/8 1/2

TWA180B40SF Epoxy Coil 460/3/60 182,000 38 34 88 SPR 816 8.8 32.9 45 13/8 1/2TWA240B40SF Epoxy Coil 460/3/60 240,000 45 44 94 SPR 934 8.8 42.5 50 13/8 1/2

TWA180BW0SF Epoxy Coil 575/3/60 182,000 38 34 88 SPR 816 8.8 26.3 35 13/8 1/2TWA240BW0SF Epoxy Coil 575/3/60 240,000 45 44 94 SPR 934 8.8 34.2 45 13/8 1/2

1 Sound Rating shown is tested in accordance with ARI standard 270 or 370.* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.

TWA – 7½ through 20 Tons

• Internal pressure relief valve• Single side service access for reduced

maintenance cost• Factory installed refrigerant drier to increase

reliability• Brazed refrigerant piping connections• Powder paint• Low ambient cooling to 50°F as shipped.• 5-year compressor warranty through 15

tons, 1-year limited parts warranty• 1-year compressor warranty on

20 ton unit, 1-year limited parts warranty

• Single refrigerant circuit on 7½ and 10 tonsizes (Trane 3-D® Scroll compressor)

• Dual refrigerant circuits on 15 and 20 tonsizes. (Two Trane 3-D® Scroll compressors)

• Service valves with pressure taps• Utilizes Trane compressor(s) for high

reliability and long life• Vertical upflow condenser discharge• Electronic time/temp. defrost control• Plate type aluminum fin/copper enhanced

tube condenser heat transfer for highefficiency to reduce energy consumption

• High/low pressure cut-out switches

Page 48: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

SH-12Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Table SH-12-A — Optional AccessoriesModelNumber Description Used With

BAYISLT005A ................... Rubber-In-Shear Isolator ................................ TWA090, 120ABAYISLT009A ................... Rubber-In-Shear Isolator ................................ TWA180BBAYISLT010A ................... Rubber-In-Shear Isolator ................................ TWA240BBAYISLT023A ................... Steel Spring Isolator ....................................... TWA090, 120ABAYISLT024A ................... Steel Spring Isolator ....................................... TWA180BBAYISLT025A ................... Steel Spring Isolator ....................................... TWA240BBAYASCT00125 ............. Anti-Short-Cycle Timer ................................... All TWA ModelsBAYSTAT033A .................. ODT 45°F to -10°F .......................................... All TWA ModelsBAYGARD024A ................ Coil Guard Kit ................................................. TWA090ABAYGARD038A ................ Coil Guard Kit ................................................. TWA120ABAYGARD028A ................ Coil Guard Kit ................................................. TWA180BBAYGARD042A ................ Coil Guard Kit ................................................. TWA240BBAYLOAM015A1 ............ Head Pressure Control-575V ......................... TWA090W,TWA180BWBAYLOAMW22A1 ........... Head Pressure Control-575V ......................... TWA120AW,TWA240BWBAYLOAM326A13 ......... Head Pressure Control-230V ......................... TWA090A3BAYLOAM327A13 ......... Head Pressure Control-230V ......................... TWA120A3BAYLOAM328A13 ......... Low Ambient Kit-230V .................................... TWA240B3BAYLOAM329A13 ......... Low Ambient Kit-230V .................................... TWA180B3BAYLOAM425A13 ......... Head Pressure Control-460V ......................... TWA090A4BAYLOAM426A13 ......... Head Pressure Control-460V ......................... TWA120A4BAYLOAM427A13 ......... Low Ambient Kit-460V .................................... TWA240B4BAYLOAM428A13 ......... Low Ambient Kit-460V .................................... TWA180B4BAYLOAM429B67 ......... Low Ambient Fan Cycle Control ..................... TWA090-240A,B,CBAYRLAY0022 ................ Time Delay Relay ........................................... TWA180-240B, TWA090-120ATAYSTAT250A .................. Outdoor Thermostat ........................................ All Heat Pump Models

Table SH-12-B — Comfort ControlsModelNumber Description Used With

BAY28X138A.................... 2 Htg/1 Clg Automatic Changeover ................ TWA090-120ABAY28X153A.................... 3 Htg/2 Clg Automatic Changeover ................ TWA180-240BBAY28X1902 ................. Locking Thermostat Cover .............................. All Room ThermostatsBAYBASE007A ................ 3 Htg/2 Clg Subbase ....................................... BAYSTAT040BBAYSENS033A ................ Remote Wall Sensor ....................................... BAYSTAT040BBAYSENS034A ................ Remote Duct Sensor ...................................... BAYSTAT040BBAYSTAT040B4 ............. Programmable Thermostat ............................. TWA090-240BBAYSTAT239 ................... 2 Htg/1 Clg Manual Changeover .................... TWA090-120ATAYSENS100A ................ Outdoor Temp. Sensor (With Case) ............... TAYSTAT500C,575TAYSTAT500C ................. XT 500C Prog., 7 Day, Man/Auto ................... All Heat Pump ModelsTAYSTAT570 ................... Electronic, 2 Htg/1 Clg (Non Prog.) ................ All Heat Pump Models

1 Quantity 1 required for each fan. (TWA180B, TWA240B)2 Do not use with programmable thermostats.3 Requires the use of BAYRLAY005A Interlock Kit.4 Requires the use of BAYBASE007A.5 Activated on Power ON.6 Option is compatible for units with electric mechanical controls unit.7 Kit mounts external to the outdoor unit and operates by sensing ambient and liquid line temperatures.

Split System Heat PumpsThree Phase – 7½ through 20 Tons

Page 49: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

TRANE 2TEH AIR HANDLER

Trane Profit-ability Sell-ability

Superior performance and appearance 4-speed fan motor Air-TiteTM cabinet Precision engineering Sound reduction Matched systems

Install-ability 6-way convertibility Tonnage 1.5 to 5 Recessed screws External drain connections

Service-ability Easy-access control box Quick filter change with standard filters External refrigerant components Easy coil cleaning

Performance-ability High efficiency 400 CFM/ton nominal airflow Thermostatic expansion valve

Rely-ability Best reliability Quiet internal check valve

QUIET AND HIGHLY EFFICIENT. DESIGNED WITH YOUR CUSTOMER IN MIND.The 2TEH air handler is the right choice for customers

looking to maximize comfort and efficiency. Ideal for new

home builders or as a replacement unit for discerning

customers, the 2TEH has a 4-speed indoor blower

distributing 400 CFM/ton nominal air flow for even,

consistent comfort every month of the year. The 2TEH

is among the quietest units we make. It has a high

efficiency blower motor and our unique VorticaTM blower

design—all in an attractive, smaller-sized package that

meets or beats the competition for reliability. And that

should yield some reliable profits for you.

TRANE LIMITED WARRANTY5-year functional parts

Reliable performancePrecision engineering, design

innovation and rigorous testing for reliable, long-lasting performance

and durability.

Better indoor airAdd a TRANE CleanEffectsTM air

cleaner and remove up to 99.98% of airborne allergens from the filtered air for a cleaner, more

comfortable home.

Comfort controlGive your customers better

comfort control with a Trane digital or programmable thermostat.

Efficient operationIncreased efficiency

may substantially lower customers’ utility costs.

TRAN

E TEH

AH

Enhanced comfortDelivers quiet, even, consistent

comfort all year round.

15633 2TEH Air Handler.indd 1 11/9/05 4:10:34 PM

Page 50: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

High efficiency 4-speed indoor blower motor Provides airflow flexibility to closely match heating and cooling requirements. Delivers exceptional air flow and efficiency.

Easy-access control boxLocated behind one easy-to-remove panel for fast installation and service.

“No Leak” base panRust-resistant, polycarbonate drain pan. Fully sloped to put an end to standing water.

Extra-large coil surfaceEnhances heat transfer, provides greater efficiency and more heating and cooling capacity.

Recessed screwsWill not snag on walls or door facings during installation.

Corrosion-resistant finishCovers all panels uniformly to resist corrosion.

Warranties generate additional income.Trane extended warranties create additional income. Selling extended warranties is another way to protect your customers and generate future business.

It all adds up to a stellar reputation.We know that when you recommend our products to customers, you are placing your livelihood and reputation in our hands. We appreciate your trust in us, and your dedication to delivering Trane technology and innovation to your customers to make their homes better places for living. You are the reason we can say, “expect more from Trane.”

trane.com

Insulated cabinetHeavy steel and insulation protects from heating and cooling losses, lowers sound levels, and is easy to clean.

Fully gasketed doorsReduces air leaks to improve efficiency, and decreases overall sound.

Easy-access filter doorsStandard off-the-shelf filters located behind one easy-to-remove door for quick and convenient filter change.

External refrigerant drain connectionsProvide for faster installation and service.

VorticaTM advanced air flow system Improves airflow while reducing energy use and operating sound. Durable composite material will not crack, corrode or rust.

Feat

ure

s an

d co

mpo

nen

ts m

ay v

ary

by m

odel

an

d a

re s

how

n for

illu

stra

tion

purp

oses

only

.

© 2005 TRANE® a business of American Standard Companies. All rights reserved. Pub. No. 2TEHAH-01 11/05

12

1

4

3

6

5

8

7

9

2

3

4

5

7

8

9

10

TRANE 2TEH AIR HANDLER

TRAN

E TEH

AH

As part of our continuous product improvement, Trane reserves the right to change specifications and design without notice.

2TEH AIR HANDLER (R-22 Refrigerant) Nominal Uncrated Power Cap. Clg. Ref. Flow Fan D imensions (in.) Model Supply (BTUH) Con Control Speed H W D

2TEH3F18A1000A 200/230/1/60 18,000 BZ TXV-NB 4 43 21.5 21

2TEH3F24A1000A 200/230/1/60 24,000 BZ TXV-NB 4 43 21.5 21

2TEH3F30A1000A 200/230/1/60 30,000 BZ TXV-NB 4 45 21.5 21

2TEH3F36A1000A 200/230/1/60 36,000 BZ TXV-NB 4 45 21.5 21

2TEH3F42A1000A 200/230/1/60 42,000 BZ TXV-NB 4 51.75 23.5 21

2TEH3F48A1000A 200/230/1/60 48,000 BZ TXV-NB 4 57.9 23.5 21

2TEH3F60A1000A 200/230/1/60 60,000 BZ TXV-NB 4 57.9 23.5 21

10

11

6

11

15633 2TEH Air Handler.indd 2 11/9/05 4:10:37 PM

Page 51: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

AH-1 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Easy Conversion to Opposite Side AccessConversion 5 – 6

Unit is shipped asHorizontal right

1

Pull coil out and rotate the coil 180°

2

Slide coil back in on supports and roll unit 180° (So primary condensate is down)

3

Note connectionsand access are now on back side of unit

4

Refrigerant connectors

Horizontal Right

Primary Condensate

Horizontal Drain PanCoil Supports

Airflow

(as shipped)

AirflowVertical Upflow(as shipped)One-Step ConversionStand unit on end

Horizontal LeftRotate Coil

Airflow

Vertical DownflowOne-Step Conversionfrom Horizontal left

Airflow

Primary Condensate

Airflow

Primary Condensate

Airflow

Airflow

Primary Condensate

Airflow

One Unit – 4 ApplicationsConversion 1 – 4

Six ConversionApplications1. Horizontal Right –

Front Access2. Vertical Upflow3. Horizontal Left –

Front Access4. Vertical Downflow5. Horizontal Right –

Rear Access6. Horizontal Left –

Rear Access

Air Handler Convertibility

Page 52: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

AH-2Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

"Air-TiteTM"Features and Benefits

heat transfer, and lower power bills.

8 Filter Door – "Filter" is stamped on the panel, and includestwo captive screws with easy grip knobs.

9 Insulation on Center Bar – Exclusive center bar insulationfor reduced cabinet loss, sweating and lower power bills.

0 Door Gasket – Exclusive formed gasket (similar to car doorgasket) to reduce air infiltration and heat transfer and lowerpower bills.

q Air-TiteTM Circuit Breaker Door – Easy access to breakerswith positive air seal.

The SEER test for system efficiency places the air handler inthe ambient return air stream (80°F). If your air handler is tobe in an unconditioned/severe climatic location, you shouldconsider the advantages of the “Air-TiteTM” model air handler.

1 Duct Flange – Allows flush fit for 3/4", 1" or 1 1/2" duct insulation

2 Liner/Flange Seal – Exclusive Duct Flange ThermalBreak/Seal and double wall construction to reducecabinet loss and sweating.

3 1" Foil Faced Insulation – Thicker foil faced insulationfor reduced cabinet loss, sweating and lower power bills.

4 Enclosed Control Box – Totally enclosed control boxwith transformer inside to improve component life, unitdurability and reliability.

5 Corrosion Resistant Screws – Exclusive “WeatherguardTM”coated screws to maintain the quality appearance of the

unit for the life of the product.

6 Coupling Panel Insulation – Exclusive “No Burn” refrigerantcoupling panel with thicker insulation for reduced heat loss.

7 Filter Door Seal – Improved door seal for reduced air infiltration,

Page 53: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

AH-3 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

• Enhanced Comfort-RTM dehumidificationstart-up

• Soft start - cycle-on speed is ramped upgradually to reduce sound and draft

• 200/230 volt primary & 24 volt, 75 VAsecondary transformer

• R 4.2-1" foil face insulated cabinet• Corrosion resistant galvanized metal with

attractive finish• Versatile duct flange - allows flush fit 3/4",

1", or 1.5" duct insulation• Low voltage terminal board• External brazed refrigerant connections• Filter panel stamped with word "filter"• Filter door seal• Exclusive duct flange thermal break/seal• Check valve for heat pump application• IAQ (Indoor Air Quality) sloped/free draining

pan, no standing water• Non-bleed expansion valve refrigerant

control• Internally enhanced finned coil tubing• Access to heater circuit breakers pull/

disconnects

11/2 through 5 TonsTWE-E (R-22) & 4TEE (R-410A)Convertible Air Handlers• Ships for vertical upflow and horizontal right

applications from factory• Six-way convertibility-horizontal (left & right);

front & rear access; upflow, downflow• Electrical, refrigerant, condensate & blower

access convertible to either side• Compact 21" depth for easy installation• Variable speed Direct drive ECM motor

Table AH-3-A — R-22 Convertible, Variable Speed with Comfort-RTM Enhanced Mode Option (200/230/1/60)Cooling

Unit Capacity Metering Fan Dimensions (in.) Shipping Supply Return Filter Line SizeModel No. (Btuh) Device Speed H x W x D Weight (Ibs.) Opening1212121212 Opening11111 Sizes Gas Liquid

TWE031E13FB 31,000 TXV-NB Variable 43x21.5x 21 134 19.22x12.02 or 18.22x 11.02 19.5x18.07 20x20x1 ¾ 5/16

TWE037E13FB 37,000 TXV-NB Variable 45x23.5x21 142 21.22x12.02 or 20.22x11.02 21.5x18.07 20x20x1 7/8 3/8TWE040E13FB 40,000 TXV-NB Variable 51.75x26x21 174 23.72x12.02 or 22.72x11.02 24x18.07 20x25x1 7/8 3/8TWE049E13FB 49,000 TXV-NB Variable 57.90x26x21 188 23.72x12.02 or 22.72x11.02 24x18.07 20x25x1 11/8 3/8TWE065E13FB3 65,000 TXV-NB Variable 62.75x26x21 218 23.72x12.02 or 22.72x11.02 24x18.07 20x25x1 11/8 3/8

Table AH-3-B — R-22 Convertible, Dual Circuit, Variable Speed with Comfort-RTM Enhanced Mode Option (200/230/1/60)TWE062E13FB3 65,000 TXV-NB(2) Variable 63x26x21 218 23.72x12.02 or 22.72x11.02 24x18.07 20x25x1 ¾ 3/8

Table AH-3-C —R-410A Variable Speed Air-Tite™ (200/230/1/60)4TEE3F31A1000A 31,000 TXV-NB Variable 43x21.5x21 134 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 3/4 5/16

4TEE3F37A1000A 37,000 TXV-NB Variable 45x23.5x21 142 21.22x12.02 or 20.22x11.02 21.5x18.07 20x20x1 3/4 3/8

4TEE3F40A1000A 40,000 TXV-NB Variable 51.75x26x21 174 23.72x12.02 or 22.72x11.02 24x18.07 20x25x1 3/4 3/8

4TEE3F49A1000A 49,000 TXV-NB Variable 57.90x26x21 188 23.72x12.02 or 22.72x11.02 24x18.07 20x25x1 7/8 3/8

4TEE3F65A1000A3 65,000 TXV-NB Variable 62.75x26x21 218 23.72x12.02 or 22.72x11.02 24x18.07 20x25x1 7/8 3/8

Table AH-3-D —R-410A Convertible, Dual Circuit, Variable Speed with Comfort-R™ Enhanced Mode Option (200/230/1/60)4TEE3F62A1000A3 65,000 TXV-NB(2) Variable 63x26x21 218 23.72x12.02 or 22.72x11.02 24x18.22 20x25x1 ¾ 3/8

Table AH-3-E – AccessoriesModel Number Description Used With

AY28X079 .................................... Evaporator Defrost Control Kit ...................... All Cooling ModelsAY28X084 .................................... Evaporator Defrost Control Kit ...................... All Heat Pump ModelsBAY99X1235 ............................... Knockout Cover Plate* ................................... TWE031E-065E, 4TEE3F31A-65ABAYSPEK140B ............................. Single Power Entry Kit .................................... BAYHTR1415BRKB, 1419BRKBTAYBASE100 ............................... Downflow Subbase ........................................ TWE037E, 4TEE3F37ATAYBASE101 ............................... Downflow Subbase ........................................ TWE031E, 4TEE3F31ATAYBASE102 ............................... Downflow Subbase ........................................ TWE040E-065E, 4TEE3F40A-65ATAYPLNM1004 ........................... Pedestal Plenum Upflow ................................ TWE031E-037E, 4TEE3F31A-37ATAYPLNM101............................... Pedestal Plenum Upflow ................................ TWE040E-065E, 4TEE3F40A-65A

• Polarized plugs for making motor andtransformer electrical connections from airhandler control box to electric heaters

• Primary and secondary drain connections• Built-in indoor fan delay function for

increased efficiency• TWE air handlers are approved for modular

or manufactured homes.• Energy saving continuous fan• Enhanced cooling/heating control Air TiteTM

• 031E airflow selectable for 1-1/2 – 3 tonO.D. unit

• 037E airflow selectable for 2 – 3-1/2 tonO.D. unit

• 040E airflow selectable for 2 – 3-1/2 tonO.D. unit

• 049E airflow selectable for 3 – 5 ton O.D.unit

• 065E airflow selectable for 3-1/2 – 5 tonO.D. unit

• 5 year limited parts residential warranty• 1 year limited parts commercial warranty• Optional extended warranties

Split System Air HandlersSingle Phase — 1½ through 5 Tons

4 4TEE3F31A-center on plenum for 2" difference in width.5 Minimum order 1 unit ( 1 unit = 50 pieces).* Required if no electric heat is used.

See Heater Tables on Pages AH-9

1 Actual opening does not include flange.2 Adjustable duct flange allows for a flush fit with

11/2 inch insulation or 3/4 inch or 1 inch insulation.3 Two (2) piece cabinet

Page 54: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

AH-4Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

• 13.0 - 14.0 SEER• High Efficiency direct drive motor• Ships for vertical upflow and horizontal right

applications from factory• Six- way convertibility-horizontal (left &

right) upflow, downflow• “1-man” installation opportunity• Electrical, refrigerant, condensate & blower

access convertible to either side• Compact 21" depth for easy

installation• Corrosion resistant galvanized metal with

attractive finish• Superior humidity performance• Enhanced internally finned coil tubes

• Versatile duct flange - allows flush fit 3/4",1", or 1.5" duct insulation

• Filter panel stamped with word "filter"• 200/230 volt primary & 24 volt secondary

transformer• Low voltage wire nut connections• Insulated cabinet• External access to heater electrical

disconnects• Polarized plugs for making electrical

connections from air handler control box toheaters

• Approved for modular or manufacturedhomes

• Optional extended warranties

Table AH-4-A — Horizontal with vertical convertibility (200/230/1/60)Cooling

Unit Capacity Metering Fan Dimensions (in.) Shipping Supply Return Filter Line SizeModel No. (Btuh) Device Speed H x W x D Weight (Ibs.) Opening1212121212 Opening11111 Sizes Gas Liquid

2TEH3F18A1000A 18,000 TXV-NB 4 43x21.5x 21 114 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x 5/8 1/42TEH3F24A1000A 24,000 TXV-NB 4 43x21.5x21 121 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 3/4 5/16

2TEH3F30A1000A 30,000 TXV-NB 4 45x21.5x21 121 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 3/4 5/16

2TEH3F36A1000A 36,000 TXV-NB 4 45x21.5x21 135 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 7/8 3/82TEH3F42A1000A 42,000 TXV-NB 4 51.8x23.5x21 165 21.22x12.02 or 20.22x11.02 21.5x18.07 20x20x1 7/8 3/82TEH3F48A1000A* 48,000 TXV-NB 4 57.9x23.5x21 188 21.22x12.02 or 20.22x11.02 21.5x18.07 20x20x1 11/8 3/82TEH3F60A1000A* 60,000 TXV-NB 4 57.9x23.5x21 193 21.22x12.02 or 20.22x11.02 21.5x18.07 20x22x1 11/8 3/8

Table AH-4-B – AccessoriesModel Number Description Used With

AY28X079 ..................................... Evaporator Defrost Control Kit ........................ All Cooling ModelsBAYSPEK140B ............................. Single Power Entry Kit .................................... BAYHTR1315BRKA, BAYHTR1319BRKATAYPLNM1001 ............................ Pedestal Plenum Upflow ................................ 2TEH3F18-60A1000ATAYBASE101 ............................... Downflow Subbase ......................................... 2TEH3F18-36A1000ATAYBASE100 ............................... Downflow Subbase ......................................... 2TEH3F42-60A1000A

1 For TEH018,024,030, center on plenum for 2" difference in width.* Two piece cabinet

BAYHTR1300 ONLYSee Heater Tables on Pages AH-8

2TEH3F18 & 24B will accommodate 10 & 15 kW Strip Heat - (BAYHTR1300 series only) in March, 2006.

Split System Air HandlersSingle Phase — 1½ through 5 Tons

11/2 through 5 TonsConvertible High EfficiencyAir Handlers

Page 55: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

AH-5 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

• 13.0 SEER• Ships for vertical upflow and horizontal right

applications from factory• Six- way convertibility-horizontal (left &

right); front & rear access; upflow,downflow

• “1-man” installation opportunity• Electrical, refrigerant, condensate & blower

access convertible to either side• Compact 21" depth for easy

installation• Corrosion resistant galvanized metal with

attractive finish• Superior humidity performance• Enhanced internally finned coil tubes• Direct drive motor

Split System Air HandlersSingle Phase — 1½ through 5 Tons

Table AH-5-A — Horizontal with vertical convertibility (200/230/1/60)Cooling

Unit Capacity Metering Fan Dimensions (in.) Shipping Supply Return Filter Line SizeModel No. (Btuh) Device Speed H x W x D Weight (Ibs.) Opening1212121212 Opening11111 Sizes Gas Liquid

2TEC3F18A1000A 18,000 TXV-NB 3 43x21.5x21 114 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 5/8 1/42TEC3F24A1000A 24,000 TXV-NB 3 43x21.5x21 121 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 3/4 5/16

2TEC3F30A1000A 30,000 TXV-NB 3 45x21.5x21 121 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 3/4 5/16

2TEC3F36A1000A 36,000 TXV-NB 3 45x21.5x21 135 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 7/8 3/82TEC3F42A1000A 42,000 TXV-NB 3 51.8x23.5x21 165 21.22x12.02 or 20.22x11.02 21.5x18.07 20x20x1 7/8 3/82TEC3F48A1000A* 48,000 TXV-NB 3 57.9x23.5x21 188 21.22x12.02 or 20.22x11.02 21.5x18.07 20x20x1 11/8 3/82TEC3F55A1000A* 60,000 TXV-NB 3 57.9x26x21 193 23.72x12.02 or 22.72x11.02 24x18.07 20x25x1 11/8 3/82TEC3F60A1000A* 60,000 TXV-NB 4 57.9x23.5x21 193 21.22x12.02 or 20.22x11.02 21.5x18.07 20x22x1 11/8 3/8

4TEC3F18A1000A 18,000 TXV-NB 3 43x21.5x21 114 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 1/2 1/44TEC3F24A1000A 24,000 TXV-NB 3 43x21.5x21 121 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 5/8 5/16

4TEC3F30A1000A 30,000 TXV-NB 3 45x21.5x21 121 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 3/4 5/16

4TEC3F36A1000A 36,000 TXV-NB 3 45x21.5x21 135 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 3/4 3/84TEC3F42A1000A 42,000 TXV-NB 3 51.8x23.5x21 165 21.22x12.02 or 20.22x11.02 21.5x18.07 20x20x1 3/4 3/84TEC3F48A1000A* 48,000 TXV-NB 3 57.9x23.5x21 188 21.22x12.02 or 20.22x11.02 21.5x18.07 20x20x1 7/8 3/84TEC3F55A1000A* 60,000 TXV-NB 3 57.9x26x21 193 23.72x12.02 or 22.72x11.02 24x18.07 20x25x1 7/8 3/84TEC3F60A1000A* 60,000 TXV-NB 4 57.9x23.5x21 193 21.22x12.02 or 20.22x11.02 21.5x18.07 20x22x1 7/8 3/8

Table AH-5-B – AccessoriesModel Number Description Used With

BAYSPEK140B ............................. Single Power Entry Kit .................................... BAYHTR1415BRKB, BAYHTR1419BRKBTAYPLNM1001 ............................ Pedestal Plenum Upflow ................................ 2/4TEC3F18-60A1000ATAYBASE101 ............................... Downflow Subbase ......................................... 2/4TEC3F18-36A1000ATAYBASE100 ............................... Downflow Subbase ......................................... 2/4TEC3F42-60A1000ABAY99X123 .................................. Knockout Cover Plate ..................................... 2/4TEC3F18-60A1000A

1 For TEC018,024,030, center on plenum for 2" difference in width.* Two piece cabinet

See Heater Tables on Pages AH-9

• Versatile duct flange - allows flush fit 3/4",1", or 1.5" duct insulation

• Filter panel stamped with word "filter"• 200/230 volt primary & 24 volt secondary

transformer• Low voltage wire nut connections• Insulated cabinet• External access to heater electrical

disconnects• Polarized plugs for making electrical

connections from air handler control box toheaters

• Approved for modular or manufacturedhomes

• Optional extended warranties11/2 through 5 Tons2/4TECConvertible Air Handlers

Page 56: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

AH-6Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Table AH-6-A — Vertical Upflow and Horizontal Left (200/230/1/60)Cooling

Unit Capacity Metering Fan Dimensions (in.) Shipping Supply Return Filter Line SizeModel No. (Btuh) Device Speed H x W x D Weight (Ibs.) Opening1212121212 Opening11111 Sizes Gas Liquid

2TGB3F18A1000A 18,000 TXV-NB 3 45.7x18x21 124 16x12.12 or 15x11.12 16x18.22 16x20x1 5/8 1/42TGB3F25A1000A 24,000 TXV-NB 3 45.7x18x21 124 16x12.12 or 15x11.12 16x18.22 16x20x1 3/4 5/16

2TGB3F30A1000A 30,000 TXV-NB 3 52x18x21 135 16x12.12 or 15x11.12 16x18.22 16x20x1 3/4 5/16

2TGB3F36A1000A 36,000 TXV-NB 3 52x18x21 135 16x12.12 or 15x11.12 16x18.22 16x20x1 7/8 3/82TGB3F42A1000A 42,000 TXV-NB 3 48.3x23.5x21 147 21.5x12.12 or 20.5x11.12 21.5x18.22 20x20x1 7/8 3/82TGB3F48A1000A 48,000 TXV-NB 3 57.3x23.5x21 172 21.5x12.12 or 20.5x11.12 21.5x18.22 20x20x1 7/8 3/8

Table AH-6-B – AccessoriesModel Number Description Used With

BAYSPEK140B ............................. Single Power Entry Kit .................................... BAYHTR1415BRKB, BAYHTR1419BRKB

See Heater Tables on Pages AH-9

• Exclusive easy to clean coil and drain pan• Convertible upflow to horizontal left (no

tools required) (matches installed units)• Designed to use "off the shelf"

standard size replaceable fiberglassfilters

• Easy to remove filters and blowers for easycleaning and replacement

• Expanded application fit with narrowcabinet profile

• Easy access electrical controls and hook-up

• Attractive enamel finish• R 4.2 - 1" insulation• Versatile duct flange - allows flush fit with

3/4", 1" or 1.5" duct insulation• Air-Tite™ cabinet - low leak by design• IAQ (Indoor Air Quality) sloped/free

draining pan (no standing water)

• Durable, glass-filled composite - Never rust,no leak drain pan

• Maximum depth 21" - fits pull-downstaircase

• Exclusive maximum width 23.5" - fits 2-ft.wide door all sizes

• External access to electrical disconnects• Direct drive motor• Filter panel stamped with word "filter"• Expansion valve (non-bleed TXV)

standard on all models• Polarized plugs for easy hook-up to electric

heaters• 200/230 volt primary and 24 volt secondary

transformer• Approved for modular or manufactured

homes• Optional extended warranties

Split System Air HandlersSingle Phase — 1½ through 4 Tons

11/2 through 4 Tons

Page 57: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

AH-7 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Table AH-7-A — Vertical Upflow and Horizontal Left (200/230/1/60)Cooling

Unit Capacity Metering Fan Dimensions (in.) Shipping Supply Return Filter Line SizeModel No. (Btuh) Device Speed H x W x D Weight (Ibs.) Opening1212121212 Opening11111 Sizes Gas Liquid

2TFB3F18B1D05A 18,000 TXV-NB 2 37x22x19.4 115 14x10.12 17.22x20 18x20x1 5/8 1/42TFB3F18B1D08A 18,000 TXV-NB 2 37x22x19.4 115 14x10.12 17.22x20 18x20x1 5/8 1/42TFB3F18B1D10A 18,000 TXV-NB 2 37x22x19.4 115 14x10.12 17.22x20 18x20x1 5/8 1/42TFB3F24B1D05A 24,000 TXV-NB 2 39x22x19.4 120 14x10.12 17.22x20 18x20x1 3/4 5/16

2TFB3F24B1D08A 24,000 TXV-NB 2 39x22x19.4 120 14x10.12 17.22x20 18x20x1 3/4 5/16

2TFB3F24B1D10A 24,000 TXV-NB 2 39x22x19.4 120 14x10.12 17.22x20 18x20x1 3/4 5/16

2TFB3F30B1D05A 30,000 TXV-NB 2 39x22x19.4 120 14x10.12 17.22x20 18x20x1 3/4 5/16

2TFB3F30B1D08A 30,000 TXV-NB 2 39x22x19.4 120 14x10.12 17.22x20 18x20x1 3/4 5/16

2TFB3F30B1D10A 30,000 TXV-NB 2 39x22x19.4 120 14x10.12 17.22x20 18x20x1 3/4 5/16

Table AH-7-B — Variable Speed R-22 (200/230/1/60)Cooling

Unit Capacity Metering Fan Dimensions (in.) Shipping Supply Return Filter Line SizeModel No. (Btuh) Device Speed H x W x D Weight (Ibs.) Opening1212121212 Opening11111 Sizes Gas Liquid

2TFE3F25B1D05A 25,000 TXV-NB Var 39x22x19.4 120 14x10.12 17.22x20 18x20x1 3/4 5/16

2TFE3F25B1D08A 25,000 TXV-NB Var 39x22x19.4 120 14x10.12 17.22x20 18x20x1 3/4 5/16

2TFE3F25B1D10A 25,000 TXV-NB Var 39x22x19.4 120 14x10.12 17.22x20 18x20x1 3/4 5/16

Table AH-7-C — Variable Speed R-410A (200/230/1/60)Cooling

Unit Capacity Metering Fan Dimensions (in.) Shipping Supply Return Filter Line SizeModel No. (Btuh) Device Speed H x W x D Weight (Ibs.) Opening1212121212 Opening11111 Sizes Gas Liquid

4TFE3F25B1D05A 25,000 TXV-NB Var 39x22x19.4 120 14x10.12 17.22x20 18x20x1 5/8 1/44TFE3F25B1D08A 25,000 TXV-NB Var 39x22x19.4 120 14x10.12 17.22x20 18x20x1 5/8 1/44TFE3F25B1D10A 25,000 TXV-NB Var 39x22x19.4 120 14x10.12 17.22x20 18x20x1 5/8 1/4* Heater kW is based on 240 volt rating.

• Shipped in vertical upflow, bottom returnwith front access & convertible to verticalupflow front return

• Variable speed ECM motor(2/4TFE Models)

• Enhanced Comfort-R™ (2/4TFE Models)• Soft start - fan speed is ramped up

gradually to reduce sound and draft(2/4TFE Models)

• Low voltage terminal board(2/4TFE Models)

• Air-Tite™ cabinet - low leakage by design• Attractive enamel finish• R 4.2-1” insulation• Exclusive easy clean coil and drain pan• Easy to remove filters and blowers for easy

cleaning and replacement

• Filter rack with throw away filter• Easy access electrical controls and

hook-up• 200/230 volt primary and 24 volt secondary

transformer• Multi-speed blower (2TFB Models)• Direct drive motor (2TFB Models)• Factory installed electric heaters• Factory installed service disconnect• Internally enhanced finned coil tubing• Primary and secondary drain connections• Approved for modular or manufactured

homes• Optional extended warranties• Five year limited parts warranty

Split System Air HandlersSingle Phase — 1½ through 2½ Tons

11/2 through 21/2 Tons

Page 58: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

AH-8Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Table AH-8-A Heaters for 2TEH onlyHeater Capacity Capacity Heater Amps ContainsModel @ 240 Volts @ 208 Volts Rated Control per Circuit CircuitNumber kW BTUH kW BTUH Voltage Stages 208 Volts 240Volt Breakers

BAYHTR1305000 4.80 16,400 3.6 12,300 208/240/1/60 1 17.3 20 NoBAYHTR1305BRK 4.80 16,400 3.6 12,300 208/240/1/60 1 17.3 20 YesBAYHTR1305PDC 4.80 16,400 3.6 12,300 208/240/1/60 1 17.3 20 NoBAYHTR1308000 7.68 26,200 5.76 19,700 208/240/1/60 1 27.7 32 NoBAYHTR1308BRK 7.68 26,200 5.76 19,700 208/240/1/60 1 27.7 32 YesBAYHTR1308PDC 7.68 26,200 5.76 19,700 208/240/1/60 1 27.7 32 NoBAYHTR1310000 9.60 32,800 7.20 24,600 208/240/1/60 1 34.6 40 NoBAYHTR1310BRK 9.60 32,800 7.20 24,600 208/240/1/60 1 34.6 40 YesBAYHTR1310PDC 9.60 32,800 7.20 24,600 208/240/1/60 1 34.6 40 NoBAYHTR1315BRK 15.36 52,400 11.53 39,300 208/240/1/60 2 34.6/20.812 40/241 YesBAYHTR1319BRK 19.20 65,500 14.42 44,200 208/240/1/60 2 27.8/41.612 32/481 YesThree PhaseBAYHTR3310000 9.60 32,800 7.20 24,600 208/240/3/60 1 30 34.6 NoBAYHTR3315000 15.36 52,400 11.53 39,300 208/240/3/60 1 33 38.2 No1 Circuit 1/Circuit 22 Heater can be converted to single circuit power entry by using

BAYSPEK140B. This kit allows a single power circuit to be used with electricheaters that contain two (2) circuit breakers.

Heaters for Split System andConvertible Air Handlers

BAYSPEK140B to be used with BAYHTR1315BRKA, BAYHTR1319BRKA.CAUTION: Any power supply and/or combination power supply, circuit or circuits must be

wired and protected in accordance with local electrical codes.

Cooling/Heat Pump Air FlowPS = Position sensitive. Minimum speed tap varies based on air handler installation position. See air handler nameplate or product data.L = LowML = Medium-LowMH = Medium-HighH = High+++ = 000 (pigtails), PCD (contains pull disconnect), BRK (contains circuit disconnects)

Table AH-9-B Heater Matrix for 2TEH only

MINIMUM HEATING AIRFLOW CFM - HEATER MATRIX

HEATER MODEL NUMBER

BAYHTR1305+++ BAYHTR1308+++ BAYHTR1310+++ BAYHTR3310000 BAYHTR1315BRK BAYHTR3315000 BAYHTR1319BRK4.80kW 7.68kW 9.60kW 9.60kW 15.36kW 15.36kW 19.20kW

NUMBER OF 1 2 2 2 3 3 4HEATER RACKSNUMBER OF 1 1 1 1 2 1 2CIRCUITS

2TEH3F18A100A L/MH L/MH N/A N/A N/A N/A N/A2TEH3F24A100A L/ML L/PS N/A N/A N/A N/A N/A2TEH3F30A100A L/L L/ML ML/H ML/H N/A N/A N/A2TEH3F36A100A L/L L/PS ML/PS ML/PS ML/H ML/H ML/H2TEH3F42A100A ML/ML ML/PS ML/MH ML/MH ML/H ML/H ML/H2TEH3F48A100A ML/ML ML/ML ML/PS ML/PS ML/H ML/H ML/H2TEH3F60A100A ML/ML ML/ML ML/ML ML/ML ML/MH ML/MH ML/H

AIR HANDLERMODEL NUMBER

Page 59: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

AH-9 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Heaters for Split System andConvertible Air Handlers

AIRHANDLER

MODELNUMBER

NUMBER OFHEATER RACKS

NUMBER OFCIRCUITS

(Example: L=Low, M=Medium, H=High Speed)PS = Minimum speed tap varies based on air

handler installation position.AS = Heater application is affected based on

whether the outdoor unit is a heat pumpor cooling unit.

000 = Pigtails, BRK = Contains circuitbreakers, PDC = Contains PullDisconnect

* For heat pump applications, upflow positiononly minimum setting is 1200

MINIMUM HEATING AIRFLOW CFM COOLING/HEAT PUMP AIR FLOW - HEATER MATRIX

HEATER MODEL NUMBER BAYHTR—

1405 000 1408 000 1410 000BRK BRK BRK 1415 BRK 3415 000 1419 BRK 1425 BRKPDC PDC PDC 15.36kW 15.36kW 19.20kW 24.96kW

4.80kW 7.68kW 3410 0009.60kW

1 2 2 2 2 4 5

1 1 1 2 1 2 3

TWE031E 700/1000 700/1000 700/1000 700/1125 700/1125 1000/1350 —TWE037E 600/700 600/900 600/900 1000/1300 1000/1300 1000/1350 —TWE040E 600/1100 600/1100 600/1100 1100/1400 1100/1400 1100/1400 1100/1400TWE049E 700/1400 700/1400 700/1400 1400/1600 1400/1600 1400/1600 1400/1600TWE062E 900/1500 900/1500 900/1500 1200/1800 1200/1800 1200/1800 1200/1800TWE065E 900/1500* 900/1500* 900/1500* 1200/1800 1200/1800 1200/1800 1200/1800

4TEE3F31A 700/1000 700/1000 700/1000 700/1125 700/1125 1000/1350 —4TEE3F37A 600/700 600/900 600/900 1000/1300 1000/1300 1000/1350 —4TEE3F40A 600/1100 600/1100 600/1100 1100/1400 1100/1400 1100/1400 1100/14004TEE3F49A 700/1400 700/1400 700/1400 1400/1600 1400/1600 1400/1600 1400/16004TEE3F65A 900/1500* 900/1500* 900/1500* 1200/1800 1200/1800 1200/1800 1200/1800

2/4TEC3F18A L/L L/M L/M — — — —2/4TEC3F24A L/L L/L L/L L/M L/M — —2/4TEC3F30A L/L L/L L/L L/M L/M — —2/4TEC3F36A L/L L/L L/L L/H L/H L/H —2/4TEC3F42A L/L L/L L/L L/PS L/PS L/H —2/4TEC3F48A L/L L/L L/L L/PS L/PS L/PS —2/4TEC3F60A L/L L/L L/L L/PS L/PS L/PS —

2TGB3F18A L/L L/M L/H N/A N/A N/A —2TGB3F25A L/L L/M L/M L/H L/H N/A —2TGB3F30A L/L L/L L/L L/M L/M N/A —2TGB3F36A L/L L/L L/L L/M L/M N/A —2TGB3F42A L/L L/L L/L L/H L/H N/A2TGB3F48A L/L L/L L/L L/H L/H L/H —

Table AH-9-B Heaters For TWE-C/D; TWE-P;TWE-E;TWG; 4TEE;2/4TEP, 2/4 TEC, 2TGBHeater Capacity Capacity Heater Amps ContainsModel @ 240 Volts @ 208 Volts Rated Control per Circuit CircuitNumber kW BTUH kW BTUH Voltage Stages 208 Volts 240Volt Breakers

BAYHTR1405000 4.80 16,400 3.6 12,300 208/240/1/60 1 17.3 20 NoBAYHTR1405BRKB 4.80 16,400 3.6 12,300 208/240/1/60 1 17.3 20 YesBAYHTR1405PDC 4.80 16,400 3.6 12,300 208/240/1/60 1 17.3 20 NoBAYHTR1408000 7.68 26,200 5.76 19,700 208/240/1/60 1 27.7 32 NoBAYHTR1408BRKB 7.68 26,200 5.76 19,700 208/240/1/60 1 27.7 32 YesBAYHTR1408PDC 7.68 26,200 5.76 19,700 208/240/1/60 1 27.7 32 NoBAYHTR1410000 9.60 32,800 7.20 24,600 208/240/1/60 1 34.6 40 NoBAYHTR1410BRKB 9.60 32,800 7.20 24,600 208/240/1/60 1 34.6 40 YesBAYHTR1410PDC 9.60 32,800 7.20 24,600 208/240/1/60 1 34.6 40 NoBAYHTR1415BRKB 15.36 52,400 11.53 39,300 208/240/1/60 2 34.6/20.812 40/241 YesBAYHTR1419BRKB 19.20 65,500 14.42 44,200 208/240/1/60 2 27.8/41.612 32/481 YesBAYHTR1425BRKB 24.96 85,200 18.73 63,900 208/240/1/60 3 38.1/34.6/17.31 44/40/201 YesThree PhaseBAYHTR3410000 9.60 32,800 7.20 24,600 208/240/3/60 1 30 34.6 NoBAYHTR3415000 15.36 52,400 11.53 39,300 208/240/3/60 1 33 38.2 No

1 Circuit 1/Circuit 22 Heater can be converted to single circuit power entry by using BAYSPEK140B. This kit allows a single power circuit to be

used with electric heaters that contain two (2) circuit breakers.BAYSPEK140B to be used with BAYHTR1415BRKB/ BAYHTR1419BRKB only.CAUTION: Any power supply and/or combination power supply, circuit or circuits must be wired and protected in accordance with local

electrical codes.

Page 60: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

AH-10Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

CAUTION: Any power supply and/or combination power supply, circuit or circuits must be wired and protected in accordance with localelectrical codes.

(Example: L=Low, M=Medium, H=High Speed)PS = Minimum speed tap varies based on air

handler installation position.AS = Heater application is affected based on

whether the outdoor unit is a heat pumpor cooling unit.

000 = Pigtails, BRK = Contains circuitbreakers, PDC = Contains PullDisconnect

* For heat pump applications, upflow positiononly minimum setting is 1200

AIRHANDLER

MODELNUMBER

NUMBER OFHEATER RACKS

NUMBER OFCIRCUITS

Heaters for Split System andConvertible Air Handlers

PHASED OUT

PHASED OUT

PHASED OUT

PHASED OUT

MINIMUM HEATING AIRFLOW CFM COOLING/HEAT PUMP AIR FLOW - HEATER MATRIX

HEATER MODEL NUMBER BAYHTR—

1405 000 1408 000 1410 000BRK BRK BRK 1415 BRK 3415 000 1419 BRK 1425 BRKPDC PDC PDC 15.36kW 15.36kW 19.20kW 24.96kW

4.80kW 7.68kW 3410 0009.60kW

1 2 2 2 2 4 5

1 1 1 2 1 2 3

TWE018P L/L L/M L/M — — — —TWE024P L/L L/L L/L L/M L/M — —TWE030P L/L L/L L/L L/M L/M — —TWE036P L/L L/L L/L L/H L/H L/H —TWE042P L/L L/L L/L PS PS L/H —TWE048P L/L L/L L/L PS PS L/H L/HTWE060P L/L L/L L/L PS PS L/H L/HTWE063P L/L L/L L/L PS PS L/H L/H

2TEP3F48B — L/L L/L L/L L/L — —2TEP3F63B — L/L L/L PS PS — —4TEP3F18A L/L L/M L/M — — — —4TEP3F24A L/L L/L L/L L/M L/M — —4TEP3F30A L/L L/L L/L L/M L/M — —4TEP3F36A L/L L/L L/L L/H L/H L/H —4TEP3F42A L/L L/L L/L PS PS L/H —4TEP3F48A L/L L/L L/L PS PS L/H L/H4TEP3F63A L/L L/L L/L PS PS L/H L/H4TEP3F48B — L/L L/L L/L L/L — —4TEP3F63B — L/L L/L L/L L/L — —

TWE018C L/L L/M L/M — — — —TWE024C L/L L/L L/L L/M L/M — —TWE030C L/L L/L L/L L/M L/M — —TWE036C L/L L/L L/L L/L L/L PS —TWE042C L/L L/L L/L L/L L/L AS —TWE048C L/L L/L L/L L/L L/L L/H L/HTWE060C/D AS L/L L/L L/L L/L L/H L/H

TWG018A L/L L/M L/H — — — —TWG025A L/L L/M L/M L/H L/H — —TWG030A L/L L/L L/L L/M L/M — —TWG036/037A L/L L/L L/L L/M L/M — —TWG042A L/L L/L L/L L/H L/H — —TWG048A L/L L/L L/L L/H L/H L/M —TWG060A L/L L/L L/L L/L L/L L/M L/H

Page 61: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

AH-11 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

PHASED OUT

PHASED OUT

PHASED OUT

• Enhanced internally finned coil tubes• Direct drive motor• IAQ (Indoor Air Quality) sloped/free draining

pan, no standing water• Versatile duct flange - allows flush fit 3/4", 1",

1.5" duct insulation• Exclusive duct flange thermal break/seal• External access to heater circuit breakers pull/

disconnects• Polarized plugs for making electrical

connections from air handler control box toheaters

• Non-bleed expansion valve refrigerant control• Approved for modular or manufactured homes• 1-year limited parts warranty• 5 year limited parts residential warranty• 1 year limited parts commercial warranty• Optional extended warranties

11/2 through 5 TonsTWE-P (R-22) & 4TEP (R-410A)Convertible Air Handlers

Split System Air HandlersSingle Phase — 1½ through 5 Tons

• 12.0 SEER• Ships horizontal - converts to upflow by

standing unit on end• Six-way convertibility-horizontal (left &

right);front & rear access; upflow, downflow• "1- man" installation opportunity• Electrical, refrigerant, condensate & blower

access convertible to either side• Compact 21" depth for easy installation• Multi-speed blower• Filter panel stamped with word "filter"• 200/230 volt primary & 24 volt secondary

transformer• Low voltage wire nut connections• R 4.2-1" foil face insulated cabinet• Corrosion resistant galvanized metal with

attractive finish• Superior condensate performance

4 Minimum Order 1 unit (1 unit = 50 pcs.)5 For TWE018P-36P, 4TEP3F18A-36A, center on plenum for 2" difference in width.** Required if no electric heat is used.

See Heater Tables on Pages AH-9

Table AH-11-A — R-22 Convertible (200/230/1/60)Cooling

Unit Capacity Fan Dimensions (in.) Shipping Supply Return Filter Line SizeModel No. (Btuh) FCCV Speed H x W x D Weight (Ibs.) Opening1212121212 Opening11111 Sizes Gas Liquid

TWE018P130B 18,000 TXV-NB 3 43x21.5x21 114 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 5/8 1/4TWE018P13FB (Air TiteTM) 18,000 TXV-NB 3 43x21.5x21 114 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 5/8 1/4TWE024P130B 24,000 TXV-NB 3 43x21.5x21 121 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 3/4 5/16

TWE024P13FB(Air TiteTM) 24,000 TXV-NB 3 43x21.5x21 121 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 3/4 5/16

TWE030P130B 30,000 TXV-NB 3 43x21.5x21 121 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 3/4 5/16

TWE030P13FB(Air TiteTM) 30,000 TXV-NB 3 43x21.5x21 121 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 3/4 5/16

TWE036P130B 36,000 TXV-NB 3 45x21.5x21 135 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 7/8 3/8TWE036P13FB(Air TiteTM) 36,000 TXV-NB 3 45x21.5x21 135 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 7/8 3/8TWE042P130B 42,000 TXV-NB 3 51.75x23.5x 21 165 21.22x12.02 or 20.22x11.02 21.5x18.07 20x20x1 7/8 3/8TWE042P13FB(Air TiteTM) 42,000 TXV-NB 3 51.75x23.5x 21 165 21.22x12.02 or 20.22x11.02 21.5x18.07 20x20x1 7/8 3/8TWE048P130B 48,000 TXV-NB 3 57.90x26x21 188 23.72x12.02 or 22.72x11.02 24x18.07 20x25x1 11/8 3/8TWE048P13FB(Air TiteTM) 48,000 TXV-NB 3 57.90x26x21 188 23.72x12.02 or 22.72x11.02 24x18.07 20x25x1 11/8 3/8TWE060P130B 58,000 TXV-NB 3 57.90x26x21 193 23.72x12.02 or 22.72x11.02 24x18.07 20x25x1 11/8 3/8TWE060P13FB(Air TiteTM) 58,000 TXV-NB 3 57.90x26x21 193 23.72x12.02 or 22.72x11.02 24x18.07 20x25x1 11/8 3/8TWE063P130B3 60,000 TXV-NB 3 62.75x26x21 211 23.72x12.02 or 22.72x11.02 24x18.07 20x25x1 11/8 3/8TWE063P13FB3(Air TiteTM) 60,000 TXV-NB 3 62.75x26x21 211 23.72x12.02 or 22.72x11.02 24x18.07 20x25x1 11/8 3/82TEP3F48B1000B3(Air TiteTM) 48,000 TXV-NB 3 57.90x23.5x21 166 21.22x12.02 or 20.22x11.02 21.5x18.07 20x20x1 11/8 3/82TEP3F63B1000B3(Air TiteTM) 60,000 TXV-NB 3 57.90x23.5x21 170 21.22x12.02 or 20.22x11.02 21.5x18.07 22x20x1 11/8 3/8

Table AH-11-B —R-410A Air-Tite™ (200/230/1/60)4TEP3F18A1000A 18,000 TXV-NB 3 43x21.5x21 114 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 1/2 1/4

4TEP3F24A1000A 24,000 TXV-NB 3 43x21.5x21 121 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 5/8 5/16

4TEP3F30A1000A 30,000 TXV-NB 3 43x21.5x21 121 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 3/4 5/16

4TEP3F36A1000A 36,000 TXV-NB 3 45 x21.5x21 135 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 3/4 3/8

4TEP3F42A1000A 42,000 TXV-NB 3 51.75x23.5x21 165 21.22x12.02 or 20.22x11.02 21.5x18.07 20x20x1 3/4 3/8

4TEP3F48A1000A 48,000 TXV-NB 3 57.90x26x21 188 23.72x12.02 or 22.72x11.02 24x18.07 20x25x1 7/8 3/8

4TEP3F63A1000A3 60,000 TXV-NB 3 62.75x26x21 211 23.72x12.02 or 22.72x11.02 24x18.07 20x25x1 7/8 3/8

4TEP3F48B1000B3 48,000 TXV-NB 3 57.90x23.5x21 166 21.22x12.02 or 20.22x11.02 21.5x18.07 20x25x1 7/8 3/8

4TEP3F63B1000B3 60,000 TXV-NB 3 57.90x23.5x21 170 21.22x12.02 or 20.22x11.02 21.5x18.07 20x25x1 7/8 3/8

Table AH-11-C – AccessoriesModel Number Description Used WithBAY24X038 .................................. Plug-In Speed Change Relay Kit ................... TWE018-063P/2, 4TEP3F18-063PBAY99X1234 ............................... Knockout Cover Plate** ................................. TWE018-063P/2, 4TEP3F18-063PBAYSPEK140A ............................ Single Power Entry Kit ................................... BAYHTR1415BRKAB, 1419BRKABTAYBASE100 ............................... Downflow Subbase ........................................ TWE042P/4TEP3F42PTAYBASE101 ............................... Downflow Subbase ........................................ TWE018-36P/4TEP3F18-36PTAYBASE102 ............................... Downflow Subbase ........................................ TWE048P-063P/2, 4TEP3F48-F63PTAYPLNM1005 ............................ Pedestal Plenum Upflow ................................ TWE018-042P/2, 4TEP3F48-F42PTAYPLNM101 ............................... Pedestal Plenum Upflow ................................ TWE048-063P/2, 4TEP3F48-F63P

1 Actual opening does not include flange.2 Adjustable duct flange allows for a flush fit with 11/2 inch insulation or 3/4 inch or 1 inch insulation.3 Two piece cabinet.

Page 62: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

AH-12Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

PHASED OUT

PHASED OUT

• Enhanced internally finned coil tubes• Direct drive motor• Standard size filters• Multi-speed blower• 200/230 volt primary & 24 volt secondary

transformer• Low voltage wire nut connections• R 4.2-1" foil face insulated cabinet• External access to heater circuit breakers• Polarized plugs for making electrical

connections from air handler control box toheaters

• Built-in indoor fan delay function forincreased efficiency. No kit required.

• Motors internally isolated• 5 year limited parts residential warranty• 1 year limited parts commercial warranty• Optional extended warranties

• Ships horizontal - converts to upflow bystanding unit on end.

• Six-way convertibility-horizontal (left &right); front & rear access; upflow, downflow

• "1-man" installation opportunity• Electrical, refrigerant, condensate & blower

access convertible to either side• Versatile duct flange - allows flush fit 3/4",

1", or 1.5" duct insulation• Compact 21" depth for easy installation• Uses BAYHTR1400 series heaters• Corrosion resistant galvanized metal with

attractive finish• IAQ (Indoor Air Quality) sloped/free draining

pan, no standing water• Approved for modular or manufactured

homes• Superior condensate performance

Split System Air HandlersSingle Phase — 1½ through 5 Tons

1½ through 5 TonsTWE-C/DConvertible Air Handlers

Table AH-12-A — Convertible (200/230/1/60)Cooling

Unit Capacity Fan Dimensions (in.) Shipping Supply Return Filter Line SizeModel No. (Btuh) FCCV Speed H x W x D Weight (Ibs.) Opening1212121212 Opening11111 Sizes Gas Liquid

TWE018C140B 18,000 .049 3 43x21.5x21 113 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 5/8 1/4TWE018C14FB (Air TiteTM) 18,000 .049 3 43x21.5x21 113 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 5/8 1/4TWE024C140B 24,000 .057 3 43x21.5x21 115 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 3/4 5/16

TWE024C14FB (Air TiteTM) 24,000 .057 3 43x21.5x21 115 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 3/4 5/16

TWE030C140B 30,000 .069 3 43x21.5x21 120 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 3/4 5/16

TWE030C14FB(Air TiteTM) 30,000 .069 3 43x21.5x21 120 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 3/4 5/16

TWE036C140B 36,000 .069 3 43x21.5x21 125 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 7/8 3/8TWE036C14FB(Air TiteTM) 36,000 .069 3 43x21.5x21 125 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 7/8 3/8TWE042C140C 42,000 .077 3 45x23.5x21 145 21.22x12.02 or 20.22x11.02 21.5x18.07 20x20x1 7/8 3/8TWE042C14FC(Air TiteTM) 42,000 .077 3 45x23.5x21 145 21.22x12.02 or 20.22x11.02 21.5x18.07 20x20x1 7/8 3/8TWE048C140C 48,000 .083 3 51.75x23.5x21 165 21.22x12.02 or 20.22x11.02 21.5x18.07 20x20x1 11/8 3/8TWE048C14FC(Air TiteTM) 48,000 .083 3 51.75x23.5x21 165 21.22x12.02 or 20.22x11.02 21.5x18.07 20x20x1 11/8 3/8TWE060D150B 60,000 TXV-B 3 57.90x23.5 x21 185 21.22x12.02 or 20.22x11.02 21.5x18.07 22x20x1 11/8 3/8TWE060C15FD3(Air TiteTM) 60,000 TXV-B 3 57.90x23.5 x21 185 21.22x12.02 or 20.22x11.02 21.5x18.07 22x20x1 11/8 3/8

Table AH-12-B – AccessoriesModel Number Description Used With

AY28X079 ...................................... Evap. Defrost Control Kit ................................. (All Cooling Models)AY28X084 ...................................... Evap. Defrost Control Kit ................................. (All Heat Pump Models)BAY24X038 .................................... Plug-in Speed Change Relay Kit ..................... TWE018-060C/DBAY99X1235 ................................. Knockout Cover Plate* .................................... TWE018-060C/DBAYSPEK140A .............................. Single Power Entry Kit .................................... BAYHTR1415BRKAB, 1419BRKABTAYBASE100 ................................. Downflow Subbase ......................................... TWE042-060C/DTAYBASE101 ................................. Downflow Subbase ......................................... TWE018-036CTAYPLNM1004 ............................. Pedestal Plenum Upflow ................................. TWE018-060C/D

1 Actual opening does not include flange.2 Adjustable duct flange allows for a flush fit with 11/2 inch insulation or 3/4 inch or 1 inch insulation.3 Two piece cabinet.4 For TWE018-036 center on plenum for 2" difference in width.5 Minimum order 1 unit (1 unit = 50 pcs.).* Required if no electric heat is used.

See Heater Tables on Pages AH-9

Page 63: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

AH-13 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

PHASED OUT

• Exclusive maximum width 231/2 inches – fits2 foot wide door

• Built-in time delay• Full line 11/2 – 5 tons• Direct drive motor• Filter panel stamped with word “filter”• AccuTronTM refrigerant control• Expansion valve (Bleed TXV) standard on

5-ton models• Polarized plugs for easy hook-up to electric

heaters• 200/230 volt primary and 24 volt secondary

transformer• Electric heaters with breaker option on all

sizes• Approved for modular or manufactured

homes• 5 year limited parts residential warranty• 1 year limited parts commercial warranty• Optional extended warranties

• Easy to clean coil and drain pan• Convertible upflow to horizontal left, (no

tools required) (matches installed units)• Designed to use “off the shelf” standard

size replaceable fiberglass filters –Industry Exclusive

• Easy to remove filters and blowers for easycleaning and replacement

• Expanded application fit with narrowcabinet profile

• Easy access electrical controls andhook-up

• Attractive enamel finish• R 4.2-1" foil face insulated cabinet• Versatile duct flange – allows flush fit 3/4, 1

or 11/2 inch duct insulation• Tight cabinet - low leak by design• IAQ (Indoor Air Quality) sloped/free draining

pan, no standing water• Durable, glass-filled Lexan – Never rust, no

leak drain pan• Maximum depth 21 inches – fits pull-down

staircase

Split System Air HandlersSingle Phase — 1½ through 5 Tons

11/2 through 5 TonsTWGConvertible Air Handlers

Table AH-13-A — Convertible (208-230/1/60)Cooling

Unit Capacity Fan Dimensions (in.) Shipping Supply Return Filter Line SizeModel No. (Btuh) FCCV Speed H x W x D Weight (Ibs.) Opening1212121212 Opening11111 Sizes Gas Liquid

TWG018A140B 18,000 .049 3 43x16x21 108 14x12.12 or 13x11.12 14x18.22 14x20x1 5/8 1/4TWG025A140B 24,000 .057 3 45.70x18x21 124 16x12.12 or 15 x11.12 16x18.22 16x20x1 3/4 5/16

TWG030A140B 30,000 .067 3 45.70x18x21 125 16x12.12 or 15 x11.12 16x18.22 16x20x1 3/4 5/16

TWG036A140B 36,000 .067 3 52x18x21 135 16x12.12 or 15 x11.12 16x18.22 16x20x1 7/8 3/8TWG037A140B 37,000 .067 3 43x21.5x21 145 19.5x12.12 or 18.5 x11.12 19.5x18.22 20x20x1 7/8 3/8TWG042A140B 42,000 .075 3 43x23.5x21 160 21.5x12.12 or 20.5x11.12 21.5x18.22 20x20x1 7/8 3/8TWG048A140B 48,000 .083 3 48.25x23.5x21 185 21.5x12.12 or 20.5x11.12 21.5x18.22 20x20x1 7/8 3/8TWG060A150B 58,000 TXV-B 3 57.25x23.5x21 205 21.5x12.12 or 20.5x11.12 21.5x18.22 22x20x1 7/8 3/81 Actual opening does not include flange.2 Adjustable duct flange allows for a flush fit with 3/4, 1 or 11/2 inch insulation.

See Heater Tables on Pages AH-9

Page 64: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

AH-14Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

PHASED OUT

PHASED OUT

Split System Air HandlersSingle Phase — 1½ through 3 Tons

• Shipped in vertical upflow front return withfront access & convertible to vertical upflowbottom return

• Tight cabinet - low leakage by design• Attractive enamel finish• R 4.2 – 1” insulation• Exclusive easy clean coil and drain pan• Easy to remove filters and blowers for easy

cleaning and replacement• Filter rack with throw away filter• Easy access electrical controls and hook –

up 200/230 volt primary and 24 voltsecondary transformer

• Built-in indoor fan delay function forincreased efficiency. No kit required

• Multi-speed blower (2TFB)• Direct drive motor (2TFB)• Factory installed electric heaters

• AccuTronTM refrigerant control (2TFB)• Standard expansion valve kits are internally

mounted (2TFB)• Factory installed service disconnect• Internally enhanced finned coil tubing• Primary and secondary drain connections• Approved for modular or manufactured

homes• Variable speed ECM motor (2TFE)• Enhanced Comfort-RTM (2TFE)• Soft start – cycle-on speed is ramped up

gradually to reduce sound (2TFE)• Low voltage terminal board (2TFE)• Expansion valve refrigerant control (2TFE)• 5 year limited parts residential warranty• 1 year limited parts commercial warranty• Optional extended warranties11/2 through 3 Tons

Table AH-14-A — (200/230/1/60)Cooling Bottom

Unit Capacity Fan Dimensions (in.) Shipping Supply Return Filter Line SizeModel No. (Btuh) FCCV Speed H x W x D Weight (Ibs.) Opening1212121212 Opening11111 Sizes Gas Liquid

2TFB4018A1D05A 18,000 .049 2 37x22x19.4 115 14 x 10.12 17.22 x 20 18x20x1 5/8 1/42TFB4018A1D08A 18,000 .049 2 37x22x19.4 115 14 x 10.12 17.22 x 20 18x20x1 5/8 1/42TFB4018A1D10A 18,000 .049 2 37x22x19.4 115 14 x 10.12 17.22 x 20 18x20x1 5/8 1/42TFB4024A1D05A 24,000 .057 2 37x22x19.4 115 14 x 10.12 17.22 x 20 18x20x1 3/4 5/16

2TFB4024A1D08A 24,000 .057 2 37x22x19.4 115 14 x 10.12 17.22 x 20 18x20x1 3/4 5/16

2TFB4024A1D10A 24,000 .057 2 37x22x19.4 115 14 x 10.12 17.22 x 20 18x20x1 3/4 5/16

2TFB4030A1D05A 30,000 .067 2 37x22x19.4 115 14 x 10.12 17.22 x 20 18x20x1 3/4 5/16

2TFB4030A1D08A 30,000 .067 2 37x22x19.4 115 14 x 10.12 17.22 x 20 18x20x1 3/4 5/16

2TFB4030A1D10A 30,000 .067 2 37x22x19.4 115 14 x 10.12 17.22 x 20 18x20x1 3/4 5/16

2TFB4036A1D05A 30,000 .067 2 39x22x19.4 120 14 x 10.12 17.22 x 20 18x20x1 7/8 3/82TFB4036A1D08A 30,000 .067 2 39x22x19.4 120 14 x 10.12 17.22 x 20 18x20x1 7/8 3/82TFB4036A1D10A 30,000 .067 2 39x22x19.4 120 14 x 10.12 17.22 x 20 18x20x1 7/8 3/8

Table AH-14-B — (200/230/1/60)Cooling Bottom

Unit Capacity Fan Dimensions (in.) Shipping Supply Return Filter Line SizeModel No. (Btuh) FCCV Speed H x W x D Weight (Ibs.) Opening1212121212 Opening11111 Sizes Gas Liquid

2TFE3025A1D05A 25,000 TXV-NB Var. 37x22x19.4 115 14 x 10.12 17.22 x 20 18x20x1 3/4 5/16

2TFE3025A1D08A 25,000 TXV-NB Var. 37x22x19.4 115 14 x 10.12 17.22 x 20 18x20x1 3/4 5/16

2TFE3025A1D10A 25,000 TXV-NB Var. 37x22x19.4 115 14 x 10.12 17.22 x 20 18x20x1 3/4 5/16

1 Actual opening does not include flange.2 Adjustable duct flange allows for a flush fit with 11/2 inch insulation or 3/4 inch or 1 inch insulation.

Page 65: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

AH-15 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

• IAQ (Indoor Air Quality) sloped/free drainingpan, no standing water

• Two inch filters factory installed on 15, 20ton units

• Supplemental heaters (electric, water,steam) fits directly on unit discharge for lowinstallation cost

• Single point power entry for reducedelectrical power installation cost

• Unit fully assembled to reduce fieldinstallation costs

• Compact design with low service clearanceto reduce building requirements

• Brazed refrigerant piping connections• Fan relay UL listed and CSA Certified• Optional extended warranties

• New 11th Digit "E" model ReliaTel™ andelectromechancial compatible.

• Upflow convertible to horizontal 5• Expansion valve factory installed• Check valves for heat pump applications• Belt drive blower• Factory installed motor, belt, sheaves,

contactor, low voltage terminal board• One inch filters on 5 to 10 ton units (rack

convertible for field supplied two inch)• Captive screws remain on the panels

for service ease• Low voltage terminal board• Drain Pan• Factory Installed (EDC) Evaporator Defrost

Control

Split System Air HandlersSingle Phase – 5 through 10 TonsThree Phase – 5 through 20 Tons

Table AH-15-A — Single Circuit CoilShipping Max Fuse Size

Unit Power Supply Capacity Drive Dimensions (in.)44444 Weight or Max CircuitTons Model No. Volts/Phase/Hz (Btuh) FCCV Type H x W x D (Ibs.) MCA* Breaker33333*

Single Phase

5 TWE060A100E 208-230/1/60 60,000 TXV Belt 48 x 39 x 23 298 7 1571/2 TWE090A100E1 208-230/1/60 90,000 TXV Belt 54 x48 x 26 388 8 1510 TWE120A100E1 208-230/1/60 120,000 TXV Belt 54 x 64 x 26 439 11 15Three Phase5 TWE060A300E 208-230/3/60 60,000 TXV Belt 48 x 39 x 23 298 4 155 TWE060A400E 460/3/60 60,000 TXV Belt 48 x 39 x 23 298 2 155 TWE060AW00E 575/3/60 60,000 TXV Belt 48 x 39 x 23 298 2 1571/2 TWE090A300E12 208-230/3/60 90,000 TXV Belt 54 x 48 x 26 388 7 1571/2 TWE090AW00E1 575/3/60 90,000 TXV Belt 54 x48 x 23 298 4 1510 TWE120A300E12 208-230/3/60 120,000 TXV Belt 54 x 64 x 26 439 8 1510 TWE120AW00E1 575/3/60 120,000 TXV Belt 54 x 64 x 26 439 4 15

Table AH-15-B— Dual Circuit CoilShipping Max Fuse Size

Unit Power Supply Capacity Drive Dimensions (in.)44444 Weight or Max CircuitTons Model No. Volts/Phase/Hz (Btuh) FCCV Type H x W x D (Ibs.) MCA* Breaker33333*

Single Phase

5 TWE060B100E 208-230/1/60 60,000 TXV Belt 48 x 39 x 23 298 7 1571/2 TWE090B100E 208-230/1/60 90,000 TXV Belt 54 x 48 x 26 388 8 1510 TWE120B100E 208-230/1/60 120,000 TXV Belt 54 x 64 x 26 439 11 15Three Phase5 TWE060B300E 208-230/3/60 60,000 TXV Belt 48 x 39 x 23 298 4 155 TWE060B400E 460/3/60 60,000 TXV Belt 48 x 39 x 23 298 2 1571/2 TWE090B300E12 208-230/3/60 90,000 TXV Belt 54 x 48 x 26 388 7 1510 TWE120B300E12 208-230/3/60 120,000 TXV Belt 54 x 64 x 26 439 8 1510 TWE120BW00E1 575/3/60 120,000 TXV Belt 54 x 64 x 26 439 4 1515 TWE180B300E 208-230/3/60 180,000 TXV Belt 69 x 80 x 28 754 12 2015 TWE180B400E 460/3/60 180,000 TXV Belt 69 x 80 x 28 754 6 1515 TWE180BW00E 575/3/60 180,000 TXV Belt 69 x 80 x 28 754 5 1520 TWE240B300E 208-230/3/60 240,000 TXV Belt 72 x 93 x 30 886 19 3020 TWE240B400E 460/3/60 240,000 TXV Belt 72 x 93 x 30 886 9 1520 TWE240BW00E 575/3/60 240,000 TXV Belt 72 x 93 x 30 886 7 15

1 Control transformer not included. Order control transformer accessory when matching these air handlers with 4-6 ton condensing units.2 Ships wired for 208-230/3/60. Field convertible to 460/3/60.3 HACR type circuit breaker per NEC.4 Dimensions based on Upflow position.5 All air handlers are shipped with the drain pan installed in the horizontal position. If an alternate position is required, the drain pan should be repositioned before

setting the air handler.* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.

5, 71/2, 10, 15, 20 Ton TWEConvertible Air Handlers(Upflow or Horizontal Only)

Page 66: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

AH-16Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Table AH-16-A — Supplementary Heaters11111Model No. Power Supply kW Rating Used With

BAYHTRL106A 208/240/1/60 4.33/5.76 TWE060-120A1, TWE060-120B1BAYHTRL112A 208/240/1/60 8.65/11.52 TWE060-120A1, TWE060-120B1BAYHTRL117A 208/240/1/60 12.98/17.28 TWE060-120A1, TWE060-120B1BAYHTRL123A 208/240/1/60 17.30/23.04 TWE060-120A1, TWE060-120B1BAYHTRL129A 208/240/1/60 21.65/28.80 TWE090-120A1, TWE090-120B1BAYHTRL305A 208/240/3/60 3.75/5.00 TWE060-120A3, TWE060-120B3BAYHTRL310A 208/240/3/60 7.45/9.96 TWE060-120A3, TWE060-120B3BAYHTRL315A 208/240/3/60 11.25/14.96 TWE060-120A3, TWE060-120B3BAYHTRL325A 208/240/3/60 18.71/24.92 TWE060-120A3, TWE060-120B3BAYHTRL335A 208/240/3/60 26.20/34.88 TWE090-120A3, TWE090-120B3BAYHTRL405A 460/3/60 5.00 TWE060A4,B4, TWE090-120A32, TWE090-120B32

BAYHTRL410A 460/3/60 9.96 TWE060A4,B4, TWE090-120A32, TWE090-120B32

BAYHTRL415A 460/3/60 14.96 TWE060A4,B4, TWE090-120A32, TWE090-120B32

BAYHTRL425A 460/3/60 24.92 TWE060A4,B4, TWE090-120A32, TWE090-120B32

BAYHTRL435A 460/3/60 34.88 TWE090,120A32, TWE090-120B32

BAYHTRLW05A 575/3/60 5.00 TWE060AW, TWE090-120AW, TWE090-120BWBAYHTRLW10A 575/3/60 9.96 TWE060AW, TWE090-120AW, TWE090-120BWBAYHTRLW15A 575/3/60 14.96 TWE060AW, TWE090-120AW, TWE090-120BWBAYHTRLW25A 575/3/60 24.92 TWE060-120AWBAYHTRLW35A 575/3/60 34.88 TWE090,120AWBAYHTRM310A 208/230/3/60 7.50/10.00 TWE180-240B3BAYHTRM320A 208/230/3/60 14.96/19.92 TWE180-240B3BAYHTRM330A 208/230/3/60 22.50/29.92 TWE180-240B3BAYHTRM350A 208/230/3/60 37.42/49.84 TWE180-240B3BAYHTRM410A 460/3/60 10.00 TWE180-240B4BAYHTRM420A 460/3/60 19.92 TWE180-240B4BAYHTRM430A 460/3/60 29.92 TWE180-240B4BAYHTRM450A 460/3/60 49.84 TWE180-240B4BAYHTRMW10A 575/3/60 10.00 TWE180-240BWBAYHTRMW20A 575/3/60 19.92 TWE180-240BWBAYHTRMW30A 575/3/60 29.92 TWE180-240BWBAYHTRMW50A 575/3/60 49.84 TWE180-240BW

1 Air Handler with heater of same voltage is single circuit single point.2 Field converted to 460/3/60.

Split System Air HandlersSingle Phase – 5 through 10 TonsThree Phase – 5 through 20 Tons

Page 67: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

AH-17 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Split System Air HandlersAccessories – 5 through 20 Tons

Table AH-17-A – AccessoriesModel Number Description Used With

BAYBASE001A1 ............. Subbase (38 W x 22 L) .............................................................................................. TWE060A, TWE060BBAYBASE002A1 ............. Subbase (471/2 W x 25 L) .......................................................................................... TWE090A, TWE090BBAYBASE003A1 ............. Subbase (631/2 W x 25 L) .......................................................................................... TWE120A, TWE120BBAYBASE004A1 ............. Subbase (791/2 W x 275/8 L) ...................................................................................... TWE180BBAYBASE005A1 ............. Subbase (921/2 W x 307/16 L) ..................................................................................... TWE240BBAYDRKT001A ................. Condensate Drain Kit ................................................................................................ TWE060BAYDRKT002A ................. Condensate Drain Kit ................................................................................................ TWE090BAYDRKT003A ................. Condensate Drain Kit ................................................................................................ TWE120BAYDRKT004A ................. Condensate Drain Kit ................................................................................................ TWE180BAYDRKT005A ................. Condensate Drain Kit ................................................................................................ TWE240BAYGRLE001A ................. Return Air Grille ......................................................................................................... TWE060A, TWE060BBAYGRLE002A ................. Return Air Grille ......................................................................................................... TWE090A, TWE090BBAYGRLE003A ................. Return Air Grille ......................................................................................................... TWE120A, TWE120BBAYGRLE004A ................. Return Air Grille ......................................................................................................... TWE180BBAYGRLE005A ................. Return Air Grille ......................................................................................................... TWE240BBAYHSMT022B ................. Oversized Motor 230/1/60 – 1 HP ............................................................................. TWE060A, TWE060BBAYHSMT023B ................. Oversized Motor 230/1/60 – 2 HP ............................................................................. TWE090A, TWE090BBAYHSMT025B ................. Oversized Motor 230-460/3/60 – 1 HP ...................................................................... TWE060A3, A4, B3, B4BAYHSMT026A ................. Oversized Motor 230-460/3/60 – 2 HP ...................................................................... TWE090A3, TWE090B3BAYHSMT027B ................. Oversized Motor 230-460/3/60 – 3 HP ...................................................................... TWE120A3BAYHSMT028A ................. Oversized Motor 230/3/60 – 5 HP ............................................................................. TWE180B3BAYHSMT029A ................. Oversized Motor 230-460/3/60 – 7.5 HP ................................................................... TWE240B3,B4BAYHSMT030A ................. Oversized Motor 460/3/60 – 5 HP ............................................................................. TWE180B4BAYHSMT035AA ............... Oversized Motor 575/3/60 – 5 HP ............................................................................. TWE180BWBAYHSMT036AA ............... Oversized Motor 575/3/60 – 7.5 HP .......................................................................... TWE240BWBAYISLT003A234 ........ Rubber-In-Shear Isolator - Floor ................................................................................ TWE060-090A, TWE060-090BBAYISLT004A234 ........ Rubber-In-Shear Isolator - Floor ................................................................................ TWE120A, TWE120BBAYISLT009A13 ............ Rubber-In-Shear Isolator - Floor ................................................................................ TWE180BBAYISLT012B1 ............... Rubber-In-Shear Isolator - Suspended ...................................................................... TWE180BBAYISLT013B34 ............ Rubber-In-Shear Isolator - Suspended ...................................................................... TWE060A, TWE060BBAYISLT014A34 ............ Rubber-In-Shear Isolator - Suspended ...................................................................... TWE090A, TWE090BBAYISLT015B34 ............ Rubber-In-Shear Isolator - Suspended ...................................................................... TWE120A, TWE120BBAYISLT016B1 ............... Rubber-In-Shear Isolator - Suspended ...................................................................... TWE240BBAYISLT018A23 ............ Spring Isolater - Floor ................................................................................................ TWE060A, TWE060BBAYISLT019A23 ............ Steel Spring Isolater - Floor ....................................................................................... TWE090-120A, TWE090-120BBAYISLT021A12 ............ Rubber-In-Shear Isolator - Floor ................................................................................ TWE180-240BBAYISLT028A3 ............... Steel Spring Isolater - Suspended ............................................................................. TWE060A, TWE060BBAYISLT029A3 ............... Spring Isolater - Suspended ...................................................................................... TWE090-120A, TWE090-120BBAYISLT030A1 ................ Rubber-In-Shear Isolator - Suspended ...................................................................... TWE180BBAYISLT031B1 ................ Rubber-In-Shear Isolator - Suspended ...................................................................... TWE240BBAYLSDR001A .................. Low Static Drive Kit ................................................................................................... TWE240BBAYLSDR003A .................. Low Static Drive Kit ................................................................................................... TWE090A, TWE090BBAYPLNM015A56 ......... Discharge Plenum and Grille ..................................................................................... TWE060A, TWE060BBAYPLNM016A56 ......... Discharge Plenum and Grille ..................................................................................... TWE090A, TWE090BBAYPLNM017A56 ......... Discharge Plenum and Grille ..................................................................................... TWE120A, TWE120BBAYPLNM018A56 ......... Hydronic Coil Discharge Plenum and Grille .............................................................. BAYWATR015A, 020BBAYPLNM019A56 ......... Hydronic Coil Discharge Plenum and Grille .............................................................. BAYWATR016A, 021BBAYPLNM020A5 ............. Hydronic Coil Discharge Plenum and Grille .............................................................. BAYWATR012A, 017BBAYPLNM021A5 ............. Hydronic Coil Discharge Plenum and Grille .............................................................. BAYWATR013A, 018BBAYPLNM022A5 ............. Hydronic Coil Discharge Plenum and Grille .............................................................. BAYWATR014A, 019BBAYPLNM025A7 ............. Electric Heat Discharge Plenum and Grille For use with TWE060A, TWE060B ....... BAYHTRL117A, 315A, 415ABAYPLNM026A7 ............. Electric Heat Discharge Plenum and Grille ............................................................... BAYHTRL117A, 123A, BAYHTRL315A, 325A,

For use with TWE090A, TWE090B ............................................................................ BAYHTRL415A, 425ABAYPLNM027A7 ............. Electric Heat Discharge Plenum and Grille ............................................................... BAYHTRL117A, 123A, BAYHTRL315A, 325A,

For use with TWE120A, TWE120B ............................................................................ BAYHTRL415A, 425ABAYPLNM028A7 ............. Electric Heat Discharge Plenum and Grille - 15 Ton ................................................. BAYHTRM330A,430A,W30ABAYPLNM029A7 ............. Electric Heat Discharge Plenum and Grille - 20 Ton ................................................. BAYHTRM330A,430A,W30ABAYTFMR003A89 ......... 77va Transformer 230v/24v ....................................................................................... TWE090-120A3, TWE090-120B3BAYTFMR004A890 ...... 77va Transformer 460v/24v ....................................................................................... TWE090-120A3, TWE090-120B3BAYTFMR005A89 ......... 77va Transformer 575v/24v ....................................................................................... TWE090AW,TWE120AW,BWBAYTFMR007A89q ...... 75va Transformer Relay and Terminal Connections 230v/24v .................................. TWE090B3-TWE120B3BAYTFMR008A80q ...... 87va Transformer Relay and Terminal Connections 460v/24v .................................. TWE090B3-TWE120B3BAYWATR012A ................. Steam Coil Encl. & Assm. (38 W x 221/8 L x 14 H) ................................................... TWE60A, TWE060BBAYWATR013A ................. Steam Coil Encl. & Assm. (475/8 W x 253/16 L x 14 H) ............................................... TWE090A, TWE090BBAYWATR014A ................. Steam Coil Encl. & Assm. (635/8 W x 253/16 L x 16 H) ............................................... TWE120A, TWE120BBAYWATR015A ................. Steam Coil Encl. & Assm. (795/8 W x 2713/16 L x 16 H) .............................................. TWE180BBAYWATR016A ................. Steam Coil Encl. & Assm. (925/8 W x 305/8 L x 18 H) ................................................ TWE240BBAYWATR017C ................. Hot Water Coil Encl. & Assm. (38 W x 221/8 L x 14 H) .............................................. TWE060A, TWE060BBAYWATR018C ................. Hot Water Coil Encl. & Assm. (475/8 W x 253/16 L x 14 H) ......................................... TWE090A, TWE090BBAYWATR019C ................. Hot Water Coil Encl. & Assm. (635/8 W x 253/16 L x 16 H) ......................................... TWE120A, TWE120BBAYWATR020C ................. Hot Water Coil Encl. & Assm. (795/8 W x 2713/16 L x 16 H) ........................................ TWE180BBAYWATR021C ................. Hot Water Coil Encl. & Assm. (925/8 W x 305/8 L x 18 H) .......................................... TWE240BBAYWRKT001A ............... Wire Kit to Achieve 180° Reversible Discharge ......................................................... TWE060-090-120A, TWE060-090-120B

6 Discharge Plenum and Grille cannot be used with Electric or Hydronic Heat options.7 See data catalog for minimum and maximum airflow requirements.8 Required when 71/2 – 10 ton Air Handlers are matched with 4 – 6 ton outdoor units.9 Required when used with Qty 2 Split System condensing units.0 When field connected for 460V.q Required when used with Qty 2 Split System Heat Pump.

1 When Air Handler is in vertical position and close proximity trapping of condensate is required,use of subbase is recommended.

2 Requires use of subbase accessory.3 Do not use with units having steam or hot water coil.4 Do not use if blower will operate less than 600 rpm.5 For vertical use only.

Page 68: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

AH-18Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

To Convert from Vertical to Horizontal Simply Lay Down

Drain Connections at Top and Bottom of Coil

Drain Connections at Top and Bottom of Coil

A Air Handler (TWE 5 – 20 Tons)

Factory SuppliedAccessories

B Outdoor Condensing Unit(TTA - Cooling 7 1/2 – 20 Tons)(TWA - Heat Pump 7 1/2 – 20 Tons)

P

P

Discharge Plenum and Grille(BAYPLNM)

EH

EH

Electric Heater and Casing (BAYHTRL)Fits on Top of Unit (13 H x 30 W x 17 D)

SB

SB

Subbase (BAYBASE)

I

I

I

Isolators (BAYISLT)

RG

RG

Return Grille (BAYGRLE)

CG

CG

Coil Guards (BAYGARD)

LA Low Ambient Control (BAYLOAM)

WCWC

Steam/Hot Water Coil (BAYWATR)

B

LA

A

Split System Air Handlers5 through 20 Tons

Page 69: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

TRANE XT90 HIGH EFFICIENCY FURNACE

TRAN

E X

T90 FU

RNA

CE

MORE ENHANCED COMFORT, EXTRA-EFFICIENT PROFITS.The TRANE XT90 furnace provides a higher efficiency,

single-stage furnace option with a bonus of added

reliability. Because it uses less electricity in both

its heating and cooling operations, it will appeal to

efficiency-minded customers for residential new

construction and replacement. It’s easy to install

and service. And can accommodate upgrades to higher

SEER outdoor units. Install it and provide an enhanced

comfort experience that will make you and your

customers more comfortable, too.

Reliable performancePrecision engineering, design

innovation and rigorous testing for reliable, long-lasting

performance and durability.

Better indoor airAdd a TRANE CleanEffectsTM

air filtration system to remove up to 99.98% of airborne allergens from the filtered air for a cleaner, more

comfortable home.

Comfort controlGive your customers better comfort control with a Trane

digital or programmable thermostat.

Enhanced comfortIntelligently designed to

deliver maximum comfort with fuel efficiency.

Efficient operationDesigned with innovative

technological touches throughout to provide the ultimate in energy

efficient operation that lowers customers’ heating costs.

TRANE LIMITED WARRANTYLifetime heat exchanger5-year functional parts

Trane Profit-ability Sell-ability

Industry leader and brand reputation Higher efficiency single-stage furnace Greater reliability Quieter operation

Install-ability Air cleaner and humidifier leads Upflow/horizontal left Downflow/horizontal right Left/right gas and electrical hookups Direct-vent option

Service-ability Quarter-turn blower door latches on upflow models Self-diagnostic controls Common parts across family Compatible with higher SEER outdoor units

Performance-ability 4-speed, high efficiency motor 90% efficiency on gas Insulated blower door and cabinet save energy and reduce sound Automotive-grade gaskets reduce air sound and infiltration

Rely-ability Each is factory tested before shipping Silicon nitride igniter 100% fresh air option Integrated furnace control Aluminized heat exchanger Multi-port in-shot burners

15633 XT90 Furnace.indd 1 9/13/05 1:41:43 PM

Page 70: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

XT90 High Efficiency, Upflow, Horizontal Left Cooling CFM Model Number AFUE Height (in.) Width (in.) Depth (in.) (Nom. tons)

TUX1B040A9H21A 92.1 40.00 17.50 28.00 2.0

TUX1B060A9H31A 92.1 40.00 17.50 28.00 3.0

TUX1B080A9H31A 92.1 40.00 17.50 28.00 3.0

TUX1C100A9H41A 92.1 40.00 21.00 28.00 4.0

TUX1D120A9H51A 92.1 40.00 24.50 28.00 5.0

XT90 High Efficiency, Downflow, Horizontal Right TDX1B040A9H31A 91.0 40.00 17.50 28.00 3.0

TDX1B060A9H31A 91.0 40.00 17.50 28.00 3.0

TDX1B080A9H31A 91.0 40.00 17.50 28.00 3.0

TDX1C100A9H41A 91.0 40.00 21.00 28.00 4.0

TDX1D120A9H51A 91.0 40.00 24.50 28.00 5.0

5

1

7

9

34

1 6

8

2

4

Warranties generate additional income.Trane extended warranties create additional income. Selling extended

warranties is another way to protect your customers and generate

future business.

It all adds up to a stellar reputation.We know that when you recommend our products to your loyal customers,

you are placing your livelihood and reputation in our hands. We salute

your expertise in delivering Trane technology and innovation to your

customers—making their homes better places for living. You are the

reason we can say, “expect more from Trane.”

9

TRAN

E X

T90 FU

RNA

CE

High efficiency blower motorControlled by a built-in microcomputer and on-board relays. Fixed 45-second time delay controls the indoor blower in heating cycles. Blower off timing is adjustable by presets, allowing you to customize comfort in the home.

Adaptive silicon nitride hot surface igniterPrevents overheating, which results in a highly reliable ignition system and longer service life.

Heavy steel insulated cabinet Easy-to-install sizes in four industry-standard widths; 40" tall. Holds more heat in the furnace and ensures greater durability and quieter operation.

Self-diagnostic controlsComplete diagnostics for easy servicing. Also includes a system fault analysis for quick gas flow shutoff, coupled with automatic ignition retry after sensing fault correction.

Easy-access doorsQuarter-turn dual door latches provide quick and easy access for servicing (upflow models only).

3

5

7

10

6

2 8

TRANE XT90 HIGH EFFICIENCY FURNACE

10

trane.com

Feat

ure

s an

d c

ompon

ents

may

var

y by

mod

el

and a

re s

how

n f

or

illust

ration p

urp

ose

s only

.

As part of our continuous product improvement, Trane reserves the right to change specifications and design without notice.

Multi-port in-shot burnersPerfectly shape the flame cone for the maximum heat possible while using less fuel. No service adjustment necessary.

Automotive-grade gaskets and insulated blower compartment Help reduce operating sound and air infiltration.

Aluminized steel heat exchanger Crimped, not welded, to prevent cracks from heat stress. Stamped serpentine channel offers the greatest efficiency in less space. Backed by our 20-year, non-prorated limited warranty.

Direct vent 100% fresh air option reduces heat exchanger corrosion and assures adequate combustion air.

Secondary heat exchanger The secondary heat exchanger is made of AL29-4CTM stainless steel to capture more of the heat your customers pay for. Backed by a lifetime limited warranty.

© 2005 TRANE® a business of American Standard Companies. All rights reserved. Pub. No. XT90FURN-01 09/05

15633 XT90 Furnace.indd 2 9/13/05 1:41:44 PM

Page 71: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

TRANE XT80 HIGH EFFICIENCY FURNACE

TRAN

E X

T80 FU

RNA

CE

OUR NEW SINGLE-STAGE, HIGH EFFICIENCY XT80 FURNACE REALLY HEATS UP YOUR SALES.With a high efficiency motor, the TRANE XT80 furnace

sets the stage for increased sales. It uses less

electricity in both its heating and cooling operations,

so it’s very attractive for new residential construction

and replacement. And it’s easy for you to install and

service. It also can accommodate upgrades to higher

SEER outdoor units. The XT80 furnace is a high

efficiency product that both you and your customers

can be comfortable with.

TRANE LIMITED WARRANTY20-year heat exchanger5-year functional parts

Trane Profit-ability

Sell-ability Industry leader and brand reputation Higher efficiency single-stage furnace Greater reliability Quieter operation

Install-ability Air cleaner and humidifier leads Upflow/horizontal left or right Downflow/horizontal left or right Left/right gas and electrical hookups

Service-ability Quarter-turn blower door latches on upflow models Self-diagnostic controls Common parts across family Compatible with higher SEER outdoor units

Performance-ability 4-speed high efficiency motor 80% efficiency on gas Insulated blower door and cabinet save energy and reduce sound Automotive-grade gaskets reduce air sound and infiltration

Rely-ability Each is factory tested before shipping Silicon nitride igniter Integrated furnace control Aluminized heat exchanger Multi-port in-shot burners

Reliable performancePrecision engineering, design

innovation and rigorous testing for reliable, long-lasting

performance and durability.

Better indoor airAdd a TRANE CleanEffectsTM air filtration system to remove up to

99.98% of airborne allergens from the filtered air for a cleaner,

more comfortable home.

Comfort controlGive your customers better comfort

control with a Trane digital or programmable thermostat.

Enhanced comfortIntelligently designed to

deliver maximum comfort with fuel efficiency.

Efficient operationDesigned with innovative

technological touches throughout to provide the ultimate in energy

efficient operation.

15633 XT80 Furnace.indd 1 9/14/05 10:03:31 AM

Page 72: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

XT80 High Efficiency, Upflow Horizontal Cooling CFM Model Number AFUE Height (in.) Width (in.) Depth (in.) (Nom. tons)

TUD1A040A9H21A 80.0 40.00 14.50 28.00 2.0 TUD1B060A9H31A 80.0 40.00 17.50 28.00 3.0 TUD1B080A9H31A 80.0 40.00 17.50 28.00 3.0 TUD1C080A9H41A 80.0 40.00 21.00 28.00 4.0 TUD1B100A9H31A 80.0 40.00 17.50 28.00 3.0 TUD1C100A9H51A 80.0 40.00 21.00 28.00 5.0 TUD1D120A9H51A 80.0 40.00 24.50 28.00 5.0 TUD1D140A9H51A 80.0 40.00 24.50 28.00 5.0

XT80 High Efficiency, Downflow Horizontal TDD1B060A9H31A 80.0 40.00 17.50 28.00 3.0 TDD1B080A9H31A 80.0 40.00 17.50 28.00 3.0 TDD1C100A9H51A 80.0 40.00 21.00 28.00 5.0 TDD1D120A9H51A 80.0 40.00 24.50 28.00 5.0

2

14

3

6

5

1 5

7

2

4

Warranties generate additional income.Trane extended warranties create additional income. Selling extended warranties is another way to protect your customers and generate future business.

It all adds up to a stellar reputation.We know that when you recommend our products to your loyal customers, you are placing your livelihood and reputation in our hands. We salute your expertise in delivering Trane technology and innovation to your customers—making their homes better places for living. You are the reason we can say “expect more from Trane.”

Easy-access doorsQuarter-turn dual door latches provide quick and easy access for servicing (upflow models only).

Multi-port in-shot burnersPerfectly shape the flame cone for the maximum heat possible while using less fuel. No service adjustment necessary.

Automotive-grade gaskets and insulated blower compartment Help reduce operating sound and air infiltration.

Aluminized steel heat exchanger Crimped, not welded, to prevent cracks from heat stress. Stamped serpentine channel offers the greatest efficiency in less space. Backed by our 20-year, non-prorated limited warranty.

TRANE XT80 HIGH EFFICIENCY FURNACE

TRAN

E X

T80 FU

RNA

CE

As part of our continuous product improvement, Trane reserves the right to change specifications and design without notice.

High efficiency blower motorControlled by a built-in microcomputer and on-board relays. Fixed 45-second time delay controls the indoor blower in heating cycles. Blower off-timing is adjustable by presets, allowing you to customize comfort in the home.

Adaptive silicon nitride hot surface igniterPrevents overheating, which results in a highly reliable ignition system and longer service life.

Heavy steel insulated cabinet Comes in easy-to-install sizes in four industry standard widths; 40" tall. Holds more heat in the furnace and ensures greater durability and quieter operation.

Self-diagnostic controlsComplete diagnostics for easy servicing. Also includes a sys-tem fault analysis for quick gas flow shutoff, coupled with automatic ignition retry after sensing fault correction.

3

6

8

trane.com

Feat

ure

s an

d co

mpo

nen

ts m

ay v

ary

by m

odel

an

d a

re s

how

n for

illu

stra

tion

purp

oses

only

.

© 2005 TRANE® a business of American Standard Companies. All rights reserved. Pub. No. XT80FURN-01 09/05

8

7

15633 XT80 Furnace.indd 2 9/14/05 10:03:32 AM

Page 73: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

TRANE ALUMINUM HIGH EFFICIENCY COMFORTTM COILS

TR AL

CO

ILS

Reliable performancePrecision engineering, design

innovation and rigorous testing for reliable, long-lasting performance

and durability.

Cleaner airAdd a TRANE CleanEffectsTM air cleaner to

remove up to 99.98% of airborne allergens from the filtered air for a cleaner,

more comfortable home.

Comfort ControlGive your customers better

comfort control with a Trane digital or programmable thermostat.

Efficient operationThe Comfort coil increases efficiency

to help substantially lower customers’ home utility costs.

Corrosion has been a long-standing problem affecting

every major HVAC manufacturer. Trane’s answer to

this environmental issue is the all-new, all-aluminum

Comfort™ coil—the only one of its kind in the industry.

By being corrosion and rust resistant, the aluminum

Comfort coil promises your customers the highest

efficiency there is and exceptional durability when

selecting this indoor coil for their matched system. The

innovative advancement and precision engineering

of the aluminum Comfort coil will be a money-saving

investment for your customer and a profit-earning

sale for you.

Trane Profit-ability

Sell-ability Industry leader with impeccable brand reputation Precision engineered

Install-ability Flush fit, easy attachment Available for different furnace widths Upflow, downflow and horizontal left airflow

Service-ability Easy-access cabinet Suction pressure service port Removable inner and outer panels TXV with mechanical fittings

Performance-ability Two-way, sloped drain pan Foil-insulated cabinet Non-bleed TXV

Rely-ability Non-corrosive parts TXV protects from refrigerant flooding

TRANE LIMITED WARRANTY10-year functional parts

INNOVATIVE TECHNOLOGY. INCREASED PROFIT MARGIN.

15633 Aluminum Coils.indd 1 9/19/05 9:07:31 AM

Page 74: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

HI-EFFICIENCY CASED UPFLOW/DOWNFLOW/HORIZONTAL LEFT (Refrigerant R-22) Nominal Uncrated Cap. Clg. Ref. Dimensions (in.) Model (BTUH) Type Control Cased H W D

2TXCB025AS3HCA 24,000 A HP TXV-NB Full 17.6 17.5 21.5

2TXCB031AS3HCA 30,000 A HP TXV-NB Full 22.6 17.5 21.5

2TXCB036AS3HCA 36,000 A HP TXV-NB Full 26.9 17.5 21.5

2TXCC037AS3HCA 37,000 A HP TXV-NB Full 26.9 21.0 21.5

2TXCC054AS3HCA 54,000 A HP TXV-NB Full 30.1 21.0 21.5

2TXCD065AS3HCA 60,000 A HP TXV-NB Full 30.1 24.5 21.5

HI-EFFICIENCY CASED UPFLOW/DOWNFLOW/HORIZONTAL LEFT (Refrigerant R-410A)

4TXCB025AS3HCA 24,000 A HP TXV-NB Full 17.6 17.5 21.5

4TXCB031AS3HCA 30,000 A HP TXV-NB Full 22.6 17.5 21.5

4TXCB036AS3HCA 36,000 A HP TXV-NB Full 26.9 17.5 21.5

4TXCC037AS3HCA 37,000 A HP TXV-NB Full 26.9 21.0 21.5

4TXCC054AS3HCA 54,000 A HP TXV-NB Full 30.1 21.0 21.5

4TXCD065AS3HCA 60,000 A HP TXV-NB Full 30.1 24.5 21.5

Foil insulation 100% foil-backed insulation provides easy cleaning for cleaner air, reduced sound operation.

Two-way, sloped, non-corrosive drain pan Prevents standing water and reduces bacteria growth which significantly improves indoor air quality. Manufactured with non-corrosive material to prevent rust.

Easy-access inner coil panelMakes cleaning and servicing easier which in turn leads to higher efficiency and longer life. Improves installation and service time.

1 4

52

3

Baked-on high gloss finish Provides increased protection from rust and corrosion. Matches furnace in color.

External service port To maintain higher performance with quicker and easier serviceability. Allows indoor evacuation and charging. Decreases service and unit down time.

TXV with mechanical fittings Allows replacement without brazing.

Warranties generate additional income.Trane extended warranties create additional income. Selling extended warranties is another way to protect your customers and generate future business.

It all adds up to a stellar reputation.We know that when you recommend our products to your loyal cus-tomers you are placing your livelihood and reputation in our hands. We salute your expertise in delivering Trane technology and innovation to your customers—making their homes a better place for living. You are the reason we can say “expect more from Trane.”

trane.com

TR AL

CO

ILS

Features and components may vary by model and are shown for illustration purposes only.

As part of our continuos product improvement, Trane reserves the right to change specifications and design without notice.

© 2005 TRANE® a business of American Standard Companies. All rights reserved. Pub. No. ALCOILS-01 09/05

TRANE ALUMINUM HIGH EFFICIENCY COMFORTTM COILS

4

1

3

2

5

6

6

15633 Aluminum Coils.indd 2 9/19/05 9:07:32 AM

Page 75: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

FUR-1 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

XV, XL, XT, XR, XB 90 ConvertibleGas Furnaces Airflow Directions

Note: Coil access is opposite of furnace.

Page 76: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

FUR-2Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

XV, XL 90Convertible Gas Furnaces

Airflow Directions:Downflow models when placed in horizontal position provide left to right airflow.Upflow models when placed in horizontal position provide right to left airflow.

XL 90 Direct/Non-Direct Vent

XV 90 Direct/Non- Direct Vent

XL 90 Direct/Non-Direct Vent

XV 90 Direct/Non- Direct Vent

Table FUR-2-A — XV Direct/Non-Direct Vent, Two-Stage, One or Two Pipe, Variable Speed, Upflow/HorizontalCondensing Gas Furnace (115/1/60)

Airflow Flue Uncrated ShippingUnit In Output (Btuh) ICS11111 Size Ignition Dimensions (in.) Weight Max FilterModel No. Tons Stage 2 Stage 1 AFUE (in) Device H x W x D (Ibs.) Fuse* Sizes

TUY060R9V3W 3 56,000 37,000 93.0 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 156 15 17 x 25 x 1TUY080R9V3W 3 73,000 48,000 92.5 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 168 15 17 x 25 x 1TUY100R9V4W 4 93,000 60,000 93.0 21/2-3 Silicon Nitride 40 x 21 x 28 197 15 20 x 25 x 1TUY120R9V5W 5 112,000 72,000 92.5 3 Only Silicon Nitride 40 x 241/2 x 28 206 15 24 x 25 x 1

Note: Variable speed XV90 furnaces should not be twinned and are not approved for twinning applications.

Table FUR-2-B — XV Direct/Non-Direct Vent, Two-Stage, One or Two Pipe, Variable Speed, Downflow/Horizontal Condensing Gas Furnace (115/1/60)

Airflow Flue Uncrated ShippingUnit In Output (Btuh) ICS11111 Size Ignition Dimensions (in.) Weight Max FilterModel No. Tons Stage 2 Stage 1 AFUE (in) Device H x W x D (Ibs.) Fuse* Sizes

TDY060R9V3W 3 56,000 36,000 92.0 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 160 15 (2) 14 x 20 x 1TDY080R9V3W 3 74,000 48,000 92.5 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 168 15 (2) 14 x 20 x 1TDY100R9V4W 4 94,000 60,000 93.0 21/2-3 Silicon Nitride 40 x 21 x 28 185 15 (2) 16 x 20 x 1TDY120R9V5W 5 112,000 72,000 92.5 3 Only Silicon Nitride 40 x 241/2 x 28 206 15 (2) 16 x 20 x 1

Note: Variable speed XV90 furnaces should not be twinned and are not approved for twinning applications.

Table FUR-2-C — XL 90 Direct/Non-Direct Vent, Two Stage, One or Two Pipe, Upflow/HorizontalCondensing Gas Furnace (115/1/60)

Airflow Flue Uncrated ShippingUnit In Output (Btuh) ICS11111 Size Ignition Dimensions (in.) Weight Max FilterModel No. Tons Stage 2 Stage 1 AFUE (in) Device H x W x D (Ibs.) Fuse* Sizes

TUX060R936W 3 56,000 36,000 93.0 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 156 15 17 x 25 x 1TUX080R942W 31/2 73,000 48,000 92.5 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 168 15 17 x 25 x 1TUX100R948W 4 93,000 60,000 93.0 21/2-3 Silicon Nitride 40 x 21x 28 197 15 20 x 25 x 1TUX120R960W 5 112,000 72,000 92.5 3 Only Silicon Nitride 40 x 241/2 x 28 206 15 24 x 25 x 1

Table FUR-2-D — XL 90 Direct/Non-Direct Vent, Two Stage, One or Two Pipe, Downflow/HorizontalCondensing Gas Furnace (115/1/60)

Airflow Flue Uncrated ShippingUnit In Output (Btuh) ICS11111 Size Ignition Dimensions (in.) Weight Max FilterModel No. Tons Stage 2 Stage 1 AFUE (in) Device H x W x D (Ibs.) Fuse* Sizes

TDX060R936W 3 55,000 36,000 92.0 2-3 Silicon Nitride 40 x 171/2 x 28 160 15 (2) 14 x 20 x 1TDX080R942W 31/2 74,000 48,000 92.5 2-3 Silicon Nitride 40 x 171/2 x 28 168 20 (2) 14 x 20 x 1TDX100R948W 4 93,000 60,000 93.0 21/2-3 Silicon Nitride 40 x 21 x 28 185 15 (2) 16 x 20 x 1TDX120R960W 5 111,000 72,000 92.5 3 Only Silicon Nitride 40 x 241/2 x 28 206 15 (2) 16 x 20 x 1

1 Isolated Combustion System.* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.

Page 77: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

FUR-3 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Table FUR-3-A — XT 90 Direct/Non-Direct Vent, Single-Stage, One or Two Pipe, Upflow/HorizontalCondensing Gas Furnace (115/1/60)

Airflow Nominal Flue Uncrated ShippingUnit In Output ICS11111 Size Ignition Dimensions (in.) Weight Max Filter**Model No. Tons (Btuh) AFUE (in) Device H x W x D (Ibs.) Fuse* Sizes

TUX1B040A9H21A 2 38,000 92.1 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 139 15 17 x 25 x 1TUX1B060A9H31A 3 56,000 92.1 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 150 15 17 x 25 x 1TUX1B080A9H31A 3 74,000 92.1 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 158 15 17 x 25 x 1TUX1C100A9H41A 4 94,000 92.1 21/2, 3 Silicon Nitride 40 x 21 x 28 171 20 20 x 25 x 1TUX1D120A9H51A 5 113,000 92.1 21/2, 3 Silicon Nitride 40 x 241/2 x 28 205 20 24 x 25 x 1

Table FUR-3-B — XT 90 Direct/Non-Direct Vent, Single-Stage, One or Two Pipe, Downflow/HorizontalCondensing Gas Furnace (115/1/60)

Airflow Nominal Flue Uncrated ShippingUnit In Output ICS11111 Size Ignition Dimensions (in.) Weight Max Filter**Model No. Tons (Btuh) AFUE (in) Device H x W x D (Ibs.) Fuse* Sizes

TDX1B040A9H21A 3 38,000 91.0 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 145 15 (2) 14 x 20 x 1TDX1B060A9H31A 3 56,000 91.0 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 155 15 (2) 14 x 20 x 1TDX1B080A9H31A 3 74,000 91.0 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 168 15 (2) 14 x 20 x 1TDX1C100A9H41A 4 94,000 91.0 21/2, 3 Silicon Nitride 40 x 21 x 28 185 20 (2) 16 x 20 x 1TDX1D120A9H51A 5 112,000 91.0 21/2, 3 Silicon Nitride 40 x 241/2 x 28 206 20 (2) 16 x 20 x 1

Table FUR-3-C — XR 90 Direct/Non-Direct Vent, Single Stage, One or Two Pipe, Upflow/HorizontalCondensing Gas Furnace (115/1/60)

Airflow Nominal Flue Uncrated ShippingUnit In Output ICS11111 Size Ignition Dimensions (in.) Weight Max Filter**Model No. Tons (Btuh) AFUE (in) Device H x W x D (Ibs.) Fuse* Sizes

TUX1B040A9241A 2 38,000 92.1 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 139 15 17 x 25 x 1TUX1B060A9361A 3 56,000 92.1 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 150 15 17 x 25 x 1TUX1B080A9421A 31/2 74,000 92.1 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 158 15 17 x 25 x 1TUX1C080A9601A 5 76,000 92.1 2, 21/2, 3 Silicon Nitride 40 x 21 x 28 171 15 20 x 25 x 1TUX1C100A9481A 4 94,000 92.1 21/2-3 Silicon Nitride 40 x 21 x 28 171 20 20 x 25 x 1TUX1D100A9601A 5 93,000 92.1 21/2-3 Silicon Nitride 40 x 241/2 x 28 197 15 24 x 25 x 1TUX1D120A9601A 5 113,000 92.1 21/2-3 Silicon Nitride 40 x 241/2 x 28 205 15 24 x 25 x 1

Table FUR-3-D — XR 90 Direct/Non-Direct Vent, Single Stage, One or Two Pipe, Downflow/HorizontalCondensing Gas Furnace (115/1/60)

Airflow Nominal Flue Uncrated ShippingUnit In Output ICS11111 Size Ignition Dimensions (in.) Weight Max Filter**Model No. Tons (Btuh) AFUE (in) Device H x W x D (Ibs.) Fuse* Sizes

TDX1B040A9241A 2 38,000 91.0 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 145 15 (2) 14 x 20 x 1TDX1B060A9361A 3 56,000 91.0 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 155 15 (2) 14 x 20 x 1TDX1B080A9421A 31/2 74,000 91.0 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 168 20 (2) 14 x 20 x 1TDX1C100A9481A 4 94,000 91.0 21/2-3 Silicon Nitride 40 x 21 x 28 185 20 (2) 16 x 20 x 1TDX1D120A9601A 5 112,000 91.0 21/2-3 Silicon Nitride 40 x 241/2 x 28 206 15 (2) 16 x 20 x 1

1 Isolated Combustion System.* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.** Filters are not shipped with furnace.

XT, XR 90Convertible Gas Furnaces

XT 90 Direct/Non- Direct Vent

XR 90 Direct Vent

Page 78: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

FUR-4Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

PHASED OUT

PHASED OUT

XB 90

XR 90 Direct Vent

XR, XB 90Convertible Gas Furnaces

Table FUR-4-A — XR 90 Direct/Non-Direct Vent, Single Stage, One or Two Pipe, Upflow/HorizontalCondensing Gas Furnace (115/1/60)

Airflow Nominal Flue Uncrated ShippingUnit In Output ICS11111 Size Ignition Dimensions (in.) Weight Max FilterModel No. Tons (Btuh) AFUE (in) Device H x W x D (Ibs.) Fuse* Sizes

TUX040C924D 2 38,000 92.1 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 139 15 17 x 25 x 1TUX060C936D 3 56,000 92.1 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 150 15 17 x 25 x 1TUX080C942D 31/2 74,000 92.1 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 158 15 17 x 25 x 1TUX080C960D 5 76,000 92.1 2, 21/2, 3 Silicon Nitride 40 x 21 x 28 171 15 20 x 25 x 1TUX100C948D 4 94,000 92.1 21/2-3 Silicon Nitride 40 x 21 x 28 171 20 20 x 25 x 1TUX100C960D 5 93,000 92.1 21/2-3 Silicon Nitride 40 x 241/2 x 28 197 15 24 x 25 x 1TUX120C960D 5 113,000 92.1 21/2-3 Silicon Nitride 40 x 241/2 x 28 205 15 24 x 25 x 1

Table FUR-4-B — XR 90 Direct/Non-Direct Vent, Single Stage, One or Two Pipe, Downflow/HorizontalCondensing Gas Furnace (115/1/60)

Airflow Nominal Flue Uncrated ShippingUnit In Output ICS11111 Size Ignition Dimensions (in.) Weight Max FilterModel No. Tons (Btuh) AFUE (in) Device H x W x D (Ibs.) Fuse* Sizes

TDX040C924D 2 38,000 91.0 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 145 15 (2) 14 x 20 x 1TDX060C936D 3 56,000 91.0 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 155 15 (2) 14 x 20 x 1TDX080C942D 31/2 74,000 91.0 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 168 20 (2) 14 x 20 x 1TDX100C948D 4 94,000 91.0 21/2-3 Silicon Nitride 40 x 21 x 28 185 20 (2) 16 x 20 x 1TDX120C960D 5 112,000 91.0 21/2-3 Silicon Nitride 40 x 241/2 x 28 206 15 (2) 16 x 20 x 1

Table FUR-4-C — XB 90 Single Stage, Single Pipe, Upflow/Horizontal Left Condensing Gas Furnace(115/1/60)

Airflow Nominal Flue Uncrated ShippingUnit In Output Size Ignition Dimensions (in.) Weight Max FilterModel No. Tons (Btuh) AFUE (in) Device H x W x D (Ibs.) Fuse* Sizes

TUC040C924B 2 37,000 92.1 2, 21/2, 3 Silicon Carbide 40 x 171/2 x 28 139 15 17 x 25 x 1TUC060C936B 3 56,000 92.1 2, 21/2, 3 Silicon Carbide 40 x 171/2 x 28 150 15 17 x 25 x 1TUC080C942B 31/2 74,000 92.1 2, 21/2, 3 Silicon Carbide 40 x 171/2 x 28 158 15 17 x 25 x 1TUC100C948B 4 94,000 92.1 2, 21/2, 3 Silicon Carbide 40 x 21 x 28 171 20 20 x 25 x 1TUC100C960B 5 93,000 92.1 2, 21/2, 3 Silicon Carbide 40 x 241/2 x 28 197 15 24 x 25 x 1TUC120C960B 5 113,000 92.1 3 Only Silicon Carbide 40 x 241/2 x 28 205 15 24 x 25 x 1

Table FUR-4-D— XB 90 Single Stage, Single Pipe, Downflow/Horizontal Right Condensing Gas Furnace(115/1/60)

Airflow Nominal Flue Uncrated ShippingUnit In Output Size Ignition Dimensions (in.) Weight Max FilterModel No. Tons (Btuh) AFUE (in) Device H x W x D (Ibs.) Fuse* Sizes

TDC040C924B 2 38,000 91.0 2, 21/2, 3 Silicon Carbide 40 x 171/2 x 28 145 15 (2) 14 x 20 x 1TDC060C936B 3 56,000 91.0 2, 21/2, 3 Silicon Carbide 40 x 171/2 x 28 155 15 (2) 14 x 20 x 1TDC080C942B 31/2 74,000 91.0 2, 21/2, 3 Silicon Carbide 40 x 171/2 x 28 168 20 (2) 14 x 20 x 1TDC100C948B 4 93,000 91.0 2, 21/2, 3 Silicon Carbide 40 x 21 x 28 185 20 (2) 16 x 20 x 1TDC120C960B 5 112,000 91.0 3 Only Silicon Carbide 40 x 241/2 x 28 206 15 (2) 16 x 20 x 1

1 Isolated Combustion System.* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.

Page 79: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

FUR-5 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

PH

AS

ED

OU

T

XV, XL, XT, XR, XB 90Convertible Gas Furnaces

Airflow Directions:Downflow models when placed in horizontal position provide leftto right airflow. Upflow models when placed in horizontal positionprovide right to left airflow.

NOTE: Variable speed XV90 furnaces should not be twinned and are not approved for twinning applications.

XV 90 XL 90 XT 90 XR 90 XR 90 XB 90TUY/TDY TUX-R/TDX-R TUX1/TDX1 TUX1/TDX1 TUX/TDX-C TUC/TDC

2 Stage/1-2 Pipe 2 Stage 1 Stage 1 Stage 1 Stage 1 StageVariable Speed 1 or 2 Pipe 1 or 2 Pipe 1or 2 Pipe 1or 2 Pipe 1 Pipe

Direct/Non Direct/Non High Efficiency Direct/Non Direct/Non Non Direct Vent Direct Vent Direct/Non Direct Vent Direct Vent DirectVent

Table FUR-5-A — Features Direct Vent• Comfort”R”™ enhanced mode (cooling) ............................ ✔ — — — — —• Adjustable heating fan off timing ........................................... ✔ ✔ ✔ ✔ ✔ ✔

• Alternate bottom/left/right return air (upflow only) ................... ✔ ✔ ✔ ✔ ✔ ✔

• Blower door safety switch .................................................... ✔ ✔ ✔ ✔ ✔ ✔

• Bottom panel ..................................................................... ✔ ✔ ✔ ✔ ✔ ✔

• Cleanable/Reusable high velocity filters ................................ ✔ ✔ — — ✔ —• Complete front service access ............................................ ✔ ✔ ✔ ✔ ✔ ✔

• Direct drive, 4-speed motor ................................................. — ✔ — ✔ ✔ ✔

• Direct drive high efficiency, 4 speed motor ............................ — — ✔ — — —• Direct drive, GE ICM variable speed blower motor ................. ✔ — — — — —• Downflow horizontal right (downflow models only) ................. TDY TDX TDX TDX TDX TDC• Dual PVC pipe venting (1 or 2 pipe option) ............................ ✔ ✔ ✔ ✔ ✔ —• Single PVC pipe venting (1 pipe only) ................................... — — — — — ✔

• Dual solenoid combination gas valve and regulator ............... ✔ ✔ ✔ ✔ ✔ ✔

• Gasketed blower door ......................................................... ✔ ✔ ✔ ✔ ✔ —• Heavy gauge reinforced wrap-around steel cabinet ............... ✔ ✔ ✔ ✔ ✔ ✔

• Hinged blower door ............................................................ ✔ ✔ ✔ ✔ ✔ —• Humidifier/EAC hook-up capability (factory wired) ................. ✔ ✔ ✔ ✔ ✔ ✔

• Inner blower door panel, downflow models only .................... TDY TDX TDX TDX TDX TDC• Insulated blower compartment 4 sides ................................. ✔ ✔ ✔ ✔ ✔ —• Cleanable Filters ................................................................ ✔ ✔ — — ✔ —• Internal filter rack ................................................................ ✔ ✔ — — ✔ —• Left/right condensate drain capability in vertical application ..... ✔ ✔ — ✔ ✔ ✔

• Lite Port/Stored diagnotics .................................................. ✔ ✔ — — — —• Mobile home approved w/BAYMFGH100A........................... ✔ ✔ ✔ ✔ ✔ —• Multi-port in shot burners ..................................................... ✔ ✔ ✔ ✔ ✔ ✔

• Painted cabinet single color ................................................. — — — — — ✔

• Painted cabinet two tone color ............................................. ✔ ✔ ✔ ✔ ✔ —• Service diagnostic capabilities ............................................. ✔ ✔ ✔ ✔ ✔ ✔

• Side out blower assembly ................................................... ✔ ✔ ✔ ✔ ✔ ✔

• Side return duct starter tabs ................................................ ✔ ✔ ✔ ✔ ✔ ✔

• Silicon Carbide hot surface igniter with adaptive heat up ........ — — — — — ✔

• Silicon Nitride hot surface igniter with adaptive heat up ........... ✔ ✔ ✔ ✔ ✔ —• Single wire twinning ............................................................ — ✔ ✔ ✔ ✔ —• Solid burner door (quiet operation) ....................................... ✔ ✔ ✔ ✔ ✔ —• 20 gauge aluminized steel heat exchanger ........................... ✔ ✔ ✔ ✔ ✔ ✔

• 24 volt secondary fuse ........................................................ ✔ ✔ ✔ ✔ ✔ ✔

• Two heating blower speeds ................................................. ✔ ✔ — — — —• Two-stage gas valve ........................................................... ✔ ✔ — — — —• Type 29-4C™ stainless steel secondary heat exchanger ....... ✔ ✔ ✔ ✔ ✔ ✔

• Upflow horizontal left (upflow models only) ............................ TUY TUX TUX TUX TUX TUC• Variable Speed venter motor ............................................... ✔ ✔ — — — —• Limited lifetime heat exchanger warranty to original owner and ✔ ✔ ✔ ✔ ✔ ✔

20-years to succeeding homeowner from date of installation• 5-year limited warranty on parts* .......................................... ✔ ✔ ✔ ✔ ✔ ✔

Page 80: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

FUR-6Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Special Use Furnace AccessoriesTable FUR-6-B — High Altitude Pressure Switch 90%Model ShippingNumber Description Used With WeightBAYHALT225 1 Switch TUC0 80,100C948,120C, TDC080,120C 2BAYHALT226 1 Switch TUC,TDC060C 2BAYHALT227 1 Switch TUC100C948 2BAYHALT228 1 Switch TUC/TDC040C 2BAYHALT230 1 Switch TUX/TDX040C, TUX1B040,D100/TDX1B040 2BAYHALT231 1 Switch TUX060C, TUX1060C 2BAYHALT232 1 Switch TUX080C, TUX1B080C 2BAYHALT233 1 Switch TUX100,120C/TDX080,120C, TUX1C100,D120/TDX1B080,D120 2BAYHALT234 1 Switch TDX100C, TDX1C100 2BAYHALT241 1 Switch TDX060C, TDX1B060 2BAYHALT245 2 Switches TDX/TUX/TDY/TUY060-R 2BAYHALT246 2 Switches TDX/TUX/TDY/TUY080,100-R 2BAYHALT247 2 Switches TDX/TUX/TDY/TUY120-R 2BAYSWT01AMALTA 1 Switch TUX/TDX120C,100C948,TUX/TDX1D120-9601,1C100-9481 2

Table FUR-6-C — Dual Fuel Heat Pump Control Kit12

Model Number Case Height Used WithTAYPLUS103A ............. Heat Pump Control Kit .............. Gas, LP., Oil and Electric FurnacesTAYSTAT250B .............. Outdoor Thermostat ................. TAYPLUS103A for Restricted ModeTHT1248 ....................... Bonnet Switch .......................... Oil Furnaces Only (Order Separately)1 Factory wired for non-restricted mode, can be wired for restricted mode.2 Applicable for all furnaces with 35 VA or larger low voltage transformer (separate high voltage power not required).

BonnetSwitch

TAYPLUS103A

PH

AS

ED

OU

T

Airflow Directions:Downflow models when placed in horizontal position provide leftto right airflow. Upflow models when placed in horizontal positionprovide right to left airflow.

XV, XL, XT, XR, XB 90Convertible Gas Furnaces

3 Includes 17" Cleanable Filter.NOTE: Variable Speed XV90 Furnaces should not be twinned and are not approved for twinning applications.

XV 90 XL 90 XT 90 XR 90 XR 90 XB 90TUY/TDY TUX-R/TDX-R TUX1/TDX1 TUX1/TDX1 TUX/TDX-C TUC/TDC

2 Stage/1-2 Pipe 2 Stage 1 Stage 1 Stage 1 Stage 1 StageVariable Speed 1 or 2 Pipe 1 or 2 Pipe 1or 2 Pipe 1or 2 Pipe 1 Pipe

Direct/Non Direct/Non Direct/Non Direct/Non Direct/Non NonTable FUR-6-A — Optional Accessories Direct Vent Direct Vent Direct Vent Direct Vent Direct Vent DirectVentBAY69X146 ........... Horizontal vent cap (Noryl) ............................ — — — — — ✔BAY69X147 ........... Wall mount flange – 3" .................................. — — ✔ ✔ ✔ ✔BAY69X148 ........... Wall mount flange – 2" .................................. — — ✔ ✔ ✔ ✔BAYBASE205 ........ Downflow subbase ....................................... ✔ ✔ ✔ ✔ ✔ ✔BAYFLTR200 ......... External side filter rack .................................. ✔ ✔ ✔ ✔ ✔ ✔BAYFLTR203 ........ Filter kit horiz conversion ............................. ✔ ✔ — — ✔ ✔

for 17.5" cabinetBAYFLTR204 ........ Filter kit horiz conversion ............................. ✔ ✔ — — ✔ ✔

for 21" cabinetBAYFLTR205 ........ Filter kit horiz conversion ............................ ✔ ✔ — — ✔ ✔

for 24.5" cabinetBAYFLTR206 ........ Filter kit ....................................................... — — ✔ ✔ ✔ ✔BAYFLTR3171 .... Cleanable filter for 17.5" ............................. ✔ ✔ ✔ ✔ ✔ ✔

cabinet upflow onlyBAYFLTR3211 .... Cleanable filter for 21" ............................... ✔ ✔ ✔ ✔ ✔ ✔

cabinet upflow onlyBAYFLTR3241 .... Cleanable filter for 24.5" ............................. ✔ ✔ ✔ ✔ ✔ ✔

cabinet upflow onlyBAYLPKT210B ..... Propane conversion kit .................................. ✔ ✔ ✔ ✔ ✔ ✔BAYLPSS210B .... LP Kit with Stainless ................................... ✔ ✔ ✔ ✔ ✔ ✔

Steel BurnersBAYMFGH100A .... Manufactured/mobile .................................. ✔ ✔ ✔ ✔ ✔ —

home kitBAYRACK960A .... Filter rack kit for upflow ............................... TUY TUX ✔ TUX TUX TUC

models only (internal)23BAYVENT100A ..... Concentric vent kit for 2, ............................. ✔ ✔ ✔ ✔ ✔ —

21/2 and 3" vent systemBAYVENT200B ..... Sidewall vent Terminator ............................. ✔ ✔ ✔ ✔ ✔ —

Kit for Direct vent furnaces1 Contains one (1) high velocity filter.2 Internal filter rack for side or bottom return air.

Page 81: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

FUR-7 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

XV, XL, XT, XR, XB 80 ConvertibleGas Furnaces Airflow Directions

Page 82: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

FUR-8Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

XV, XL 80, ConvertibleGas Furnaces

XV 80

Table FUR-8-A — XV 80 Variable Speed, Two-Stage, Upflow/Horizontal Left or Right Induced Draft GasFurnace (115/1/60)

Airflow Flue Uncrated ShippingUnit In Output (Btuh) Size Ignition Dimensions (in.) Weight Max FilterModel No. Tons Stage 2 Stage 1 AFUE (in) Device H x W x D (Ibs.) Fuse* Sizes

TUD060R9V3K 3 48,000 31,200 80.0 4 Silicon Nitride 40 x 171/2 x 28 136 15 17 x 25 x 1TUD080R9V3K 3 64,000 41,600 80.0 4 Silicon Nitride 40 x 171/2 x 28 142 15 17 x 25 x 1TUD080R9V4K 4 64,000 41,600 80.0 4 Silicon Nitride 40 x 21 x 28 166 15 17 x 25 x 1TUD100R9V3K 3 80,000 52,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 142 15 17 x 25 x 1TUD100R9V5K 5 79,000 52,000 80.0 4 Silicon Nitride 40 x 21 x 28 166 15 20 x 25 x 1TUD120R9V5K 5 97,000 62,400 80.0 4 Silicon Nitride 40 x 241/2 x 28 186 15 24 x 25 x 1TUD140R9V5K 5 111,000 72,800 80.0 4 Silicon Nitride 40 x 241/2 x 28 197 15 24 x 25 x 1NOTE: Variable speed XV80 furnaces should not be twinned and are not approved for twinning applications.

Table FUR-8-B — XV 80 Variable Speed, Two-Stage, Downflow/Horizontal Left or Right Induced Draft GasFurnace (115/1/60)

Airflow Flue Uncrated ShippingUnit In Output (Btuh) Size Ignition Dimensions (in.) Weight Max FilterModel No. Tons Stage 2 Stage 1 AFUE (in) Device H x W x D (Ibs.) Fuse* Sizes

TDD060R9V3F 3 48,000 31,200 80.0 4 Silicon Nitride 40 x 171/2 x 28 140 15 (2) 14 x 20 x 1TDD080R9V3F 3 63,000 41,600 80.0 4 Silicon Nitride 40 x 171/2 x 28 146 15 (2) 14 x 20 x 1TDD100R9V5F 5 81,000 52,000 80.0 4 Silicon Nitride 40 x 21 x 28 166 15 (2) 16 x 20 x 1TDD120R9V5F 5 95,000 62,400 80.0 4 Silicon Nitride 40 x 241/2 x 28 197 15 (2) 16 x 20 x 1NOTE: Variable speed XV80 furnaces should not be twinned and are not approved for twinning applications.

Table FUR-8-C — XL 80 Two-Stage, Upflow/Horizontal, Left or Right Induced Draft Gas Furnace (115/1/60)Airflow Flue Uncrated Shipping

Unit In Output (Btuh) Size Ignition Dimensions (in.) Weight Max FilterModel No. Tons Stage 2 Stage 1 AFUE (in) Device H x W x D (Ibs.) Fuse* Sizes

TUD040R924K 2 32,000 20,800 80.0 4 Silicon Nitride 40 x 141/2 x 28 119 15 17 x 25 x 1**TUD060R936K 3 47,000 31,200 80.0 4 Silicon Nitride 40 x 141/2 x 28 127 15 17 x 25 x 1**TUD060R937K 3 47,000 31,200 80.0 4 Silicon Nitride 40 x 171/2 x 28 137 15 17 x 25 x 1TUD080R936K 3 63,000 41,600 80.0 4 Silicon Nitride 40 x 171/2 x 28 142 15 17 x 25 x 1TUD080R948K 4 63,000 41,600 80.0 4 Silicon Nitride 40 x 171/2 x 28 142 15 17 x 25 x 1TUD100R936K 3 79,000 52,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 151 15 17 x 25 x 1TUD100R948K 4 79,000 52,000 80.0 4 Silicon Nitride 40 x 21 x 28 162 15 20 x 25 x 1TUD100R960K 5 80,000 52,000 80.0 4 Silicon Nitride 40 x 21 x 28 162 15 20 x 25 x 1TUD100R961K 5 80,000 52,000 80.0 4 Silicon Nitride 40 x 241/2 x 28 175 20 24 x 25 x 1TUD120R954K 5 95,000 62,400 80.0 4 Silicon Nitride 40 x 21 x 28 176 20 20 x 25 x 1TUD120R960K 5 95,000 62,400 80.0 4 Silicon Nitride 40 x 241/2 x 28 186 20 24 x 25 x 1TUD140R960K 5 112,000 72,800 80.0 4 Silicon Nitride 40 x 241/2 x 28 192 20 24 x 25 x 1

Table FUR-8-D — XL 80 Two-Stage, Downflow/Horizontal Left or Right Induced Draft (115/1/60)Airflow Flue Uncrated Shipping

Unit In Output (Btuh) Size Ignition Dimensions (in.) Weight Max FilterModel No. Tons Stage 2 Stage 1 AFUE (in) Device H x W x D (Ibs.) Fuse* Sizes

TDD040R924F 2 32,000 20,800 80.0 4 Silicon Nitride 40 x 141/2 x 28 125 15 (2) 14 x 20 x 1TDD060R936F 3 47,000 31,200 80.0 4 Silicon Nitride 40 x 141/2 x 28 135 15 (2) 14 x 20 x 1TDD060R937F 3 47,000 31,200 80.0 4 Silicon Nitride 40 x 171/2 x 28 147 15 (2) 14 x 20 x 1TDD080R936F 3 64,000 41,600 80.0 4 Silicon Nitride 40 x 171/2 x 28 152 15 (2) 14 x 20 x 1TDD100R945F 4 79,000 52,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 157 15 (2) 14 x 20 x 1TDD100R948F 4 79,000 52,000 80.0 4 Silicon Nitride 40 x 21 x 28 166 15 (2) 16 x 20 x 1TDD100R960F 5 81,000 52,000 80.0 4 Silicon Nitride 40 x 21 x 28 168 15 (2) 16 x 20 x 1TDD120R960F 5 96,000 62,400 80.0 4 Silicon Nitride 40 x 241/2 x 28 189 15 (2) 16 x 20 x 1TDD140R960F 5 113,000 72,800 80.0 4 Silicon Nitride 40 x 241/2 x 28 196 15 (2) 16 x 20 x 1

* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.** Ship with filter sizes. May be trimmed for bottom return.

XL 80

XL 80

XV 80

Page 83: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

FUR-9 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Table FUR-9-A — XT 80 Single Stage, Upflow Horizontal, Left or Right Induced Draft Gas Furnace (115/1/60)Airflow Nominal Flue Uncrated Shipping

Unit In Output Size Ignition Dimensions (in.) Weight Max Filter**Model No. Tons (Btuh) AFUE (in.) Device H x W x D (Ibs.) Fuse* Sizes

TUD1A040A9H21A 2 32,000 80 4 Silicon Nitride 40 x 141/2 x 28 119 15 17 x 25 x 1TUD1B060A9H31A 3 47,000 80 4 Silicon Nitride 40 x 171/2 x 28 127 15 17 x 25 x 1TUD1B080A9H31A 3 63,000 80 4 Silicon Nitride 40 x 171/2 x 28 142 15 17 x 25 x 1TUD1C080A9H41A 4 64,000 80 4 Silicon Nitride 40 x 21 x 28 142 20 20 x 25 x 1TUD1B100A9H31A 3 79,000 80 4 Silicon Nitride 40 x 171/2 x 28 151 20 17 x 25 x 1TUD1C100A9H51A 5 79,000 80 4 Silicon Nitride 40 x 21 x 28 162 20 20 x 25 x 1TUD1D120A9H51A 5 96,000 80 4 Silicon Nitride 40 x 241/2 x 28 186 20 24 x 25 x 1TUD1D140A9H51A 5 111,000 80 4 Silicon Nitride 40 x 241/2 x 28 193 20 24 x 25 x 1

Table FUR-9-B — XT 80 Single Stage, Downflow Horizontal, Left or Right Induced Draft Gas Furnace (115/1/60)Airflow Nominal Flue Uncrated Shipping

Unit In Output Size Ignition Dimensions (in.) Weight Max Filter**Model No. Tons (Btuh) AFUE (in.) Device H x W x D (Ibs.) Fuse* Sizes

TDD1B060A9H31A 3 48,000 80 4 Silicon Nitride 40 x 171/2 x 28 139 15 (2) 14 x 20 x 1TDD1B080A9H31A 3 64,000 80 4 Silicon Nitride 40 x 171/2 x 28 146 15 (2) 14 x 20 x 1TDD1C100A9H51A 5 81,000 80 4 Silicon Nitride 40 x 21 x 28 167 20 (2) 16 x 20 x 1TDD1D120A9H51A 5 96,000 80 4 Silicon Nitride 40 x 241/2 x 28 189 20 (2) 16 x 20 x 1

Table FUR-9-C — XR 80 Single Stage, Upflow/Horizontal Left or Right Induced Draft Gas Furnace (115/1/60)Airflow Nominal Flue Uncrated Shipping

Unit In Output Size Ignition Dimensions (in.) Weight Max Filter**Model No. Tons (Btuh) AFUE (in.) Device H x W x D (Ibs.) Fuse* Sizes

TUD1A040A9241A 2 32,000 80.0 4 Silicon Nitride 40 x 141/2 x 28 119 15 17 x 25 x 1TUD1A040A9301A 21/2 32,000 80.0 4 Silicon Nitride 40 x 141/2 x 28 122 15 17 x 25 x 1TUD1A060A9241A 2 47,000 80.0 4 Silicon Nitride 40 x 141/2 x 28 124 15 17 x 25 x 1TUD1A060A9361A 3 47,000 80.0 4 Silicon Nitride 40 x 141/2 x 28 127 15 17 x 25 x 1TUD1B060A9361A 3 47,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 137 15 17 x 25 x 1TUD1B080A9241A 2 64,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 139 15 17 x 25 x 1TUD1B080A9361A 3 63,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 142 15 17 x 25 x 1TUD1B080A9481A 4 64,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 142 15 17 x 25 x 1TUD1C080A9601A 5 64,000 80.0 4 Silicon Nitride 40 x 21 x 28 154 15 20 x 25 x 1TUD1C100A9361A 3 79,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 151 15 17 x 25 x 1TUD1C100A9451A 4 80,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 153 15 17 x 25 x 1TUD1C100A9481A 4 79,000 80.0 4 Silicon Nitride 40 x 21 x 28 162 15 20 x 25 x 1TUD1C100A9601A 5 79,000 80.0 4 Silicon Nitride 40 x 21 x 28 162 20 20 x 25 x 1TUD1D100A9721A 6 80,000 80.0 4 Silicon Nitride 40 x 241/2 x 28 175 20 24 x 25 x 1TUD1C120A9541A 5 96,000 80.0 4 Silicon Nitride 40 x 21 x 28 176 20 20 x 25 x 1TUD1D120A9601A 5 96,000 80.0 4 Silicon Nitride 40 x 241/2 x 28 186 20 24 x 25 x 1TUD1D140A9601A 5 111,000 80.0 4 Silicon Nitride 40 x 241/2 x 28 193 20 24 x 25 x 1

Table FUR-9-D — XR 80 Single Stage, Downflow/Horizontal Left or Right Induced Draft Gas Furnace (115/1/60)Airflow Nominal Flue Uncrated Shipping

Unit In Output Size Ignition Dimensions (in.) Weight Max Filter**Model No. Tons (Btuh) AFUE (in.) Device H x W x D (Ibs.) Fuse* Sizes

TDD1A040A9241A 2 31,000 78.0 4 Silicon Nitride 40 x 141/2 x 28 119 15 (2) 14 x 20 x 1TDD1A060A9241A 2 48,000 80.0 4 Silicon Nitride 40 x 141/2 x 28 129 15 (2) 14 x 20 x 1TDD1A060A9361A 3 48,000 80.0 4 Silicon Nitride 40 x 141/2 x 28 129 15 (2) 14 x 20 x 1TDD1B060A9361A 3 48,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 141 15 (2) 14 x 20 x 1TDD1B080A9361A 3 64,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 146 15 (2) 14 x 20 x 1TDD1B080A9451A 4 64,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 146 15 (2) 14 x 20 x 1TDD1B100A9451A 4 80,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 156 15 (2) 14 x 20 x 1TDD1C100A9481A 4 80,000 80.0 4 Silicon Nitride 40 x 21 x 28 166 15 (2) 16 x 20 x 1TDD1C100A9541A 5 81,000 80.0 4 Silicon Nitride 40 x 21 x 28 167 15 (2) 16 x 20 x 1TDD1C120A9541A 5 96,000 80.0 4 Silicon Nitride 40 x 21 x 28 177 15 (2) 16 x 20 x 1TDD1D120A9601A 5 96,000 80.0 4 Silicon Nitride 40 x 241/2 x 28 189 15 (2) 16 x 20 x 1TDD1D140A9601A 5 113,000 80.0 4 Silicon Nitride 40 x 241/2 x 28 196 15 (2) 16 x 20 x 1

* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.** Filters are not shipped with furnace.

XT, XR 80Convertible Gas Furnaces

XT 80Upflow

XT 80Downflow

XR 80

XR 80

Page 84: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

FUR-10Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

PHASED OUT

PHASED OUT

XR, XB 80Convertible Gas Furnaces

Table FUR-10-A — XR 80 Single Stage, Upflow/Horizontal Left or Right Induced Draft Gas Furnace (115/1/60)Airflow Nominal Flue Uncrated Shipping

Unit In Output Size Ignition Dimensions (in.) Weight Max FilterModel No. Tons (Btuh) AFUE (in.) Device H x W x D (Ibs.) Fuse* Sizes

TUD040C924K 2 32,000 80.0 4 Silicon Nitride 40 x 141/2 x 28 119 15 17 x 25 x 1TUD040C930K 21/2 32,000 80.0 4 Silicon Nitride 40 x 141/2 x 28 122 15 17 x 25 x 1TUD060C924K 2 47,000 80.0 4 Silicon Nitride 40 x 141/2 x 28 124 15 17 x 25 x 1TUD060C936K 3 47,000 80.0 4 Silicon Nitride 40 x 141/2 x 28 127 15 17 x 25 x 1TUD060C937K 3 47,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 137 15 17 x 25 x 1TUD080C924K 2 64,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 139 15 17 x 25 x 1TUD080C936K 3 63,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 142 15 17 x 25 x 1TUD080C948K 4 64,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 142 15 17 x 25 x 1TUD080C960K 5 64,000 80.0 4 Silicon Nitride 40 x 21 x 28 154 15 20 x 25 x 1TUD100C936K 3 79,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 151 15 17 x 25 x 1TUD100C945K 4 80,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 153 15 17 x 25 x 1TUD100C948K 4 79,000 80.0 4 Silicon Nitride 40 x 21 x 28 162 15 20 x 25 x 1TUD100C960K 5 79,000 80.0 4 Silicon Nitride 40 x 21 x 28 162 20 20 x 25 x 1TUD100C972K 6 80,000 80.0 4 Silicon Nitride 40 x 241/2 x 28 175 20 24 x 25 x 1TUD120C954K 5 96,000 80.0 4 Silicon Nitride 40 x 21 x 28 176 20 20 x 25 x 1TUD120C960K 5 96,000 80.0 4 Silicon Nitride 40 x 241/2 x 28 186 20 24 x 25 x 1TUD140C960K 5 111,000 80.0 4 Silicon Nitride 40 x 241/2 x 28 193 20 24 x 25 x 1

Table FUR-10-B — XR 80 Single Stage, Downflow/Horizontal Left or Right Induced Draft Gas Furnace (115/1/60)Airflow Nominal Flue Uncrated Shipping

Unit In Output Size Ignition Dimensions (in.) Weight Max FilterModel No. Tons (Btuh) AFUE (in.) Device H x W x D (Ibs.) Fuse* Sizes

TDD040C924F 2 31,000 78.0 4 Silicon Nitride 40 x 141/2 x 28 119 15 (2) 14 x 20 x 1TDD060C924F 2 48,000 80.0 4 Silicon Nitride 40 x 141/2 x 28 129 15 (2) 14 x 20 x 1TDD060C936F 3 48,000 80.0 4 Silicon Nitride 40 x 141/2 x 28 129 15 (2) 14 x 20 x 1TDD060C937F 3 48,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 141 15 (2) 16 x 20 x 1TDD080C936F 3 64,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 146 15 (2) 14 x 20 x 1TDD080C945F 4 64,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 146 15 (2) 16 x 20 x 1TDD100C945F 4 80,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 156 15 (2) 16 x 20 x 1TDD100C948F 4 80,000 80.0 4 Silicon Nitride 40 x 21 x 28 166 15 (2) 16 x 20 x 1TDD100C954F 5 81,000 80.0 4 Silicon Nitride 40 x 21 x 28 167 15 (2) 16 x 20 x 1TDD120C954F 5 96,000 80.0 4 Silicon Nitride 40 x 21 x 28 177 15 (2) 16 x 20 x 1TDD120C960F 5 96,000 80.0 4 Silicon Nitride 40 x 241/2 x 28 189 15 (2) 16 x 20 x 1TDD140C960F 5 113,000 80.0 4 Silicon Nitride 40 x 241/2 x 28 196 15 (2) 16 x 20 x 1

Table FUR-10-C — XB 80 Single Stage, Upflow/Horizontal Left or Right Induced Draft Gas Furnace (115/1/60)Airflow Nominal Flue Uncrated Shipping

Unit In Output Size Ignition Dimensions (in.) Weight Max FilterModel No. Tons (Btuh) AFUE (in.) Device H x W x D (Ibs.) Fuse* Sizes

TUE040A924L 2 31,000 80.0 4 Silicon Carbide 40 x 141/2 x 28 119 15 16 x 25 x 1TUE060A936L 3 47,000 80.0 4 Silicon Carbide 40 x 141/2 x 28 127 15 16 x 25 x 1TUE060A937L 3 47,000 80.0 4 Silicon Carbide 40 x 171/2 x 28 137 15 17 x 25 x 1TUE080A936L 3 63,000 80.0 4 Silicon Carbide 40 x 171/2 x 28 142 15 17 x 25 x 1TUE080A948L 4 64,000 80.0 4 Silicon Carbide 40 x 171/2 x 28 142 15 17 x 25 x 1TUE100A936L 3 79,000 80.0 4 Silicon Carbide 40 x 171/2 x 28 151 15 17 x 25 x 1TUE100A948L 4 79,000 80.0 4 Silicon Carbide 40 x 21 x 28 162 15 20 x 25 x 1TUE100A960L 5 79,000 80.0 4 Silicon Carbide 40 x 21 x 28 162 15 20 x 25 x 1TUE120A960L 5 96,000 80.0 4 Silicon Carbide 40 x 241/2 x 28 186 20 24 x 25 x 1TUE140A960L 5 111,000 80.0 4 Silicon Carbide 40 x 241/2 x 28 193 20 24 x 25 x 1

Table FUR-10-D — XB 80 Single Stage, Downflow/Horizontal Left or Right Induced Draft Gas Furnace (115/1/60)Airflow Nominal Flue Uncrated Shipping

Unit In Output Size Ignition Dimensions (in.) Weight Max FilterModel No. Tons (Btuh) AFUE (in.) Device H x W x D (Ibs.) Fuse* Sizes

TDE060A936M 3 48,000 80.0 4 Silicon Carbide 40 x 141/2 x 28 129 15 (2) 14 x 20 x 1TDE060A937M 3 48,000 80.0 4 Silicon Carbide 40 x 171/2 x 28 134 15 (2) 14 x 20 x 1TDE080A945M 4 64,000 80.0 4 Silicon Carbide 40 x 171/2 x 28 146 15 (2) 14 x 20 x 1TDE100A945M 4 80,000 80.0 4 Silicon Carbide 40 x 171/2 x 28 156 15 (2) 14 x 20 x 1TDE100A960M 5 81,000 80.0 4 Silicon Carbide 40 x 21 x 28 167 20 (2) 16 x 20 x 1TDE120A960M 5 96,000 80.0 4 Silicon Carbide 40 x 241/2 x 28 189 20 (2) 16 x 20 x 1

*Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.

XB 80

XR 80

XR 80

Page 85: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

FUR-11 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

PH

AS

ED

OU

T

XV, XL, XT, XR, XB 80Convertible Gas Furnaces

Airflow Directions:Downflow models when placed in horizontal position provide leftto right airflow. Upflow models when placed in horizontal positionprovide right to left airflow.

XV 80 XL 80 XT 80 XR 80 XR 80 XB 80TUD-R-V-K TUD-R-K TUD1/TDD1 TUD1/TDD1 TUD-C-K TUE/TDE

TDD-R-V-F 2-Stg. TDD-R-F 1 Stage 1 Stage TDD-C-K 1 StageVariable Speed 2 Stage 1 or 2 Pipe 1 Stage

Table FUR-11-A — Features High Efficiency• Comfort-R™ enhanced mode (cooling) ............................. ✔ — — — — —• Adjustable heating fan off timing .......................................... ✔ ✔ ✔ ✔ ✔ ✔• Adjustable internal filter rack1 ............................................ ✔ ✔ — — ✔ —• Alternate bottom/left/right return air1 ................................... ✔ ✔ ✔ ✔ ✔ ✔• Attractive color accents ...................................................... ✔ ✔ ✔ ✔ ✔ —• Blower door safety switch ................................................... ✔ ✔ ✔ ✔ ✔ ✔• Bottom Panel1 ................................................................. ✔ ✔ ✔ ✔ ✔ —• Cleanable/reusable high velocity filters ................................ ✔ ✔ — — ✔ —• Common vent capability ..................................................... ✔ ✔ ✔ ✔ ✔ ✔• Complete front service access ........................................... ✔ ✔ ✔ ✔ ✔ ✔• Direct drive, 4-speed motor ................................................ — ✔ ✔ ✔ ✔ ✔• Direct drive,GE ICM variable speed blower motor ................ ✔ — — — — —• Filter ................................................................................. ✔ ✔ — — ✔ —• Gasketed blower door ........................................................ ✔ ✔ ✔ ✔ ✔ —• Heavy gauge reinforced wrap-around steel cabinet .............. ✔ ✔ ✔ ✔ ✔ ✔• Hinged blower door1 ........................................................ ✔ ✔ ✔ ✔ ✔ —• Horizontal left/right without conversion required .................... ✔ ✔ ✔ ✔ ✔ ✔• Humidifier/EAC hook-up capability (factory-wired) ................ ✔ ✔ ✔ ✔ ✔ —• Inner blower door panel on downflow models only ................ ✔ ✔ ✔ ✔ ✔ ✔• Insulated blower compartment 4 sides1 ............................. ✔ ✔ ✔ ✔ ✔ —• Integrated solid state control w/self diagnostics .................... ✔ ✔ ✔ ✔ ✔ ✔• Internal filter rack ............................................................... ✔ ✔ — — ✔ —• Left/right gas connection .................................................... ✔ ✔ ✔ ✔ ✔ ✔• Manual reset flame roll out switches .................................... ✔ ✔ ✔ ✔ ✔ ✔• Manually resettable burner switches ................................... ✔ ✔ ✔ ✔ ✔ ✔• Masonry Chimney Venting w/BAYVENT800B...................... ✔ ✔ ✔ ✔ ✔ —• Multi-port in shot burners .................................................... ✔ ✔ ✔ ✔ ✔ ✔• Painted cabinet single color ................................................ — — — — — ✔• Perfect fit door latches1 ..................................................... ✔ ✔ ✔ ✔ ✔ —• Right or left hand side knock out for venting ......................... ✔ ✔ ✔ ✔ ✔ ✔

(downflow models only)• Selectable cooling fan off delay eliminates need ................... ✔ ✔ ✔ ✔ ✔ ✔

for time delay relay BAY24X045• Service diagnostic sight glass ............................................. ✔ ✔ ✔ ✔ ✔ —• Side return starter tabs ...................................................... TUD TUD TUD TUD TUD TUE• Silicon Carbide hot surface igniter with adaptive heat up ....... — — — — — ✔• Silicon Nitride hot surface igniter with adaptive heat up .......... ✔ ✔ ✔ ✔ ✔ —• Single door filter access ..................................................... ✔ ✔ ✔ ✔ ✔ —• Single wire twinning ........................................................... — ✔ ✔ ✔ ✔ —• Slide out blower assembly .................................................. ✔ ✔ ✔ ✔ ✔ ✔• Standard filter sizes1 ........................................................ ✔ ✔ ✔ ✔ ✔ —• 3-way vent option on downflow models (top,right or left) ........ ✔ ✔ ✔ ✔ ✔ ✔

(downflow only) .................................................................• 20 gauge aluminized steel heat exchanger .......................... ✔ ✔ ✔ ✔ ✔ ✔• 24 volt secondary fuse ....................................................... ✔ ✔ ✔ ✔ ✔ ✔• Two heating blower speeds ............................................... ✔ ✔ — — — —• Two speed venter motor .................................................... ✔ ✔ — — — —• Two tone color ................................................................... ✔ ✔ ✔ ✔ ✔ —• Two-stage gas valve .......................................................... ✔ ✔ — — — —• Non-prorated 20-year heat exchanger limited warranty ......... ✔ ✔ ✔ ✔ ✔ ✔

(Residential only)*• 5-year limited warranty on parts* ......................................... ✔ ✔ ✔ ✔ ✔ ✔1 Upflow only.

NOTE: Variable speed XV80 furnaces should not be twinned and are not approved for twinning applications.

Page 86: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

FUR-12Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Airflow Directions:Downflow models when placed in horizontal position provide leftto right airflow. Upflow models when placed in horizontal positionprovide right to left airflow.

XV, XL, XT, XR, XB 80Convertible Gas Furnaces

Special Use Furnace Accessories

Table FUR-12-B — High Altitude Pressure Switch 80%Model ShippingNumber Description Used With WeightBAYHALT248 1 Switch TUD-C-K/TDD-C-F.TUE-A-L/TDE-A-M, 2

TUD1, TDD1BAYHALT249 1 Switch TUD-R-K,TDD-R-F 2

Table FUR-12-C — Dual Fuel Heat Pump Control Kit1212121212

Model Number Case Height Used WithTAYPLUS103A ........... Heat Pump Control Kit ........... Gas, LP., Oil and Electric FurnacesTAYSTAT250B ........... Outdoor Thermostat ............... TAYPLUS103A for Restricted ModeTHT1248 ..................... Bonnet Switch ........................ Oil Furnaces Only (Order Separately)1 Factory wired for non-restricted mode, can be wired for restricted mode.2 Applicable for all furnaces with 35 VA or larger low voltage transformer (separate high voltage power not required).

BonnetSwitch

TAYPLUS103A

PH

AS

ED

OU

T

XV 80 XL 80 XT 80 XR 80 XR 80 XB 80TUD-R-V-K TUD-R-K TUD1/TDD1 TUD1/TDD1 TUD-C-K TUE-TDE

TDD-R-V-F 2-Stg. TDD-R-F 1 Stage 1 Stage TDD-C-F 1 StageTable FUR-12-A — Optional Accessories Variable Speed 2 Stage High Efficiency 1 StageBAYBASE205 ........... Downflow subbase for ................................ ✔ ✔ ✔ ✔ ✔ ✔

downflow models onlyBAYFLTR200 ............ Side Filter Rack (External) .......................... ✔ ✔ — TUD1 — —BAYFLTR203 ............ Filter kit horiz conversion ............................ ✔ ✔ — — ✔

for 17.5" cabinetBAYFLTR204 ............ Filter kit horiz conversion ............................ ✔ ✔ — — ✔ ✔

for 21" cabinetBAYFLTR205 ............ Filter kit horiz conversion ............................ ✔ ✔ — — ✔ ✔

for 24.5" cabinetBAYFLTR206 ............ Filter Access Door Kit ................................ ✔ ✔ TDD1 TDD1 ✔ ✔BAYFLTR3171 ......... Cleanable filter for 14.5" ........................... — — ✔ ✔ — ✔

and 17.5" cabinet upflow onlyBAYFLTR3211 ......... Cleanable filter for .................................... ✔ ✔ ✔ ✔ ✔ ✔

21" cabinet upflow onlyBAYFLTR3241 ......... Cleanable filter for .................................... ✔ ✔ ✔ ✔ ✔ ✔

24.5" cabinet upflow onlyBAYLPKT210B ......... Propane conversion kit ............................... ✔ ✔ ✔ ✔ ✔ ✔BAYLPSS210B ......... LP Kit with Stainless .................................. ✔ ✔ ✔ ✔ ✔ ✔

Steel BurnersBAYRACK960A235 . Filter Rack Kit for upflow ............................. TUD TUD ✔ ✔ TUD TUE

models only (internal)BAYVENT800B4 ...... Masonry chimney vent kit ........................... ✔ ✔ ✔ ✔ — —1 Contains one (1) high velocity filter.2 Available for models with 1800 CFM or greater witch require an additional side return.3 Upflow only.4 TUD-C-J/TUD-R-J and later5 Includes 17" Cleanable Filter.NOTE: Variable Speed XV80 Furnaces should not be twinned and are not approved for twinning applications.

Page 87: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

FUR-13 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

XV80 Variable SpeedHigh Efficiency Oil Furnaces

Table FUR-13-A — Specifications: Airflow Nominal Uncrated

Model In Tons Cap-BTUH ICS FLue Dimensions(In.) Mfg. ShippingNumber (Nom.) *Htg Output AFUE Size H W D Plant WeightTHV1M087A9V3SAA 3 87,000 82.4 6" 58 22.25 31 TR 260THV1M087A9V5SAA 5 87,000 82.6 6" 58 22.25 31 TR 260TLF1M087A9V3SAA 3 87,000 82.0 6" 41.5 22.25 47 TR 300TLF1M087A9V5SAA 5 87,000 82.7 6" 41.5 22.25 47 TR 300TLR1M087A9V3SAA 3 87,000 82.0 6" 41.5 22.25 47 TR 300TLR1M087A9V5SAA 5 87,000 82.4 6" 41.5 22.25 47 TR 300TDF1M087A9V5SAA 3 87,000 81.7 6" 22.25 61.25 22.25 TR 280TDF1M087A9V5SAA 5 87,000 82.6 6" 22.25 61.25 22.25 TR 280* Other input/output capacities are available by changing the burner nozzle. See installer's guide for details.

Table FUR-13-B — Accessories:Mfg. Shipping

Model Description Used With Plant WeightBAYSUB10ABASEAA Downflow Subbase TDF1M087A9V3, 9V5SAA TR 22BAYTRM10AVENTAA Top Panel & Trim Ring THV1M087A9V3, 9V5SAA TR 1

• Up to 82.7% Annual Fuel Utilization Efficiency(AFUE)

• 13 gauge hot rolled steel wrap around heatexchanger for durability

• Beckett Flame Retention Burner operatescleanly and quietly

• Burner features include primary control withinterrupted ignition for reliability, pre-purge andclean cutoff solenoid valve for smooth ignition

• Burner and controls factory wired• Dual clean out ports for quick access and easy

cleaning• Insulated blower compartment• Variable speed blower motor

• Slide out blower assembly for quickcleaning and service accessibility

• Filter rack with cleanable filter (Highboy &Lowboy Models) except Downflow/Horizontal

• 5 year limited parts warranty• Limited lifetime heat exchanger warranty• Preformed ceramic fiber

combustion chamber for higher efficienciesand more complete combustion

• 40 VA control transformer for add oncooling

• Heavy gauge, powder painted (two tone),steel cabinet

TDF -Downflow/Horizontal

TLF -Lowboy FrontFlue (TLR not shown)

THV -Highboy Vertical

• Recessed door handles for easy removal ofHighboy & lowboy Furnace doors

• Lowboy models available with front or rearflue option

• Highboy models with top or right sideventing

• Downflow/Horizontal model fieldconvertible from Downflow to right or lefthorizontal

• 6” Left and Right side fresh air knockouts –Highboy and Lowboy Models

• Barometric draft regulator included

Page 88: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

FUR-14Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

XP80 High Efficiency Oil Furnaces

Table FUR-14-A — Specifications: Airflow Nominal Uncrated

Model In Tons Cap-BTUH ICS FLue Dimensions(In.) Mfg. ShippingNumber (Nom.) *Htg Output AFUE Size H W D Plant WeightTHV1M087A936SAA 3 87,000 82.4 6" 58 22.25 31 TR 260THV1M087A948SAA 4 87,000 82.4 6" 58 22.25 31 TR 260TLF1M087A936SAA 3 87,000 82.0 6" 41.5 22.25 47 TR 300TLF1M087A948SAA 4 87,000 82.0 6" 41.5 22.25 47 TR 300TLR1M087A936SAA 3 87,000 82.0 6" 41.5 22.25 47 TR 300TLR1M087A948SAA 4 87,000 82.0 6" 41.5 22.25 47 TR 300TDF1M087A936SAA 3 87,000 81.7 6" 22.25 61.25 22.25 TR 280TDF1M087A948SAA 4 87,000 81.7 6" 22.25 61.25 22.25 TR 280

* Other input/output capacities are available by changing the burner nozzle. See installer's guide for details.

Table FUR-14-B — Accessories:Mfg. Shipping

Model Description Used With Plant WeightBAYSUB10ABASEAA Downflow Subbase TDF1M087A936, 948SAA TR 22BAYTRM10AVENTAA Top Panel & Trim Ring THV1M087A936, 948SAA TR 1

• Up to 82.4% Annual Fuel UtilizationEfficiency (AFUE)

• 13 gauge hot rolled steel wrap around heatexchanger for durability

• Beckett Flame Retention Burner operatescleanly and quietly

• Burner features include primary control withinterrupted ignition for reliability, pre-purgeand clean cutoff solenoid valve for smoothignition

• Burner and controls factory wired• Dual clean out ports for quick access and

easy cleaning• Direct drive, permanently lubricated, 4

speed blower motor

• Insulated blower compartment• Slide out blower assembly for quick cleaning

and service accessibility• Filter rack with washable filter (Highboy &

Lowboy Models) except Downflow/Horizontal• 5 year parts limited warranty and lifetime heat

exchanger warranty• Preformed ceramic fiber

combustion chamber for higher efficienciesand more complete combustion

• 40 VA control transformer for add on cooling• Heavy gauge, powder painted (two tone),

steel cabinet

TDF -Downflow/Horizontal

TLF -Lowboy FrontFlue (TLR not shown)

THV -Highboy Vertical

• Recessed door handles for easy removal ofHighboy & lowboy Furnace doors

• Lowboy models available with front or rearflue option

• Highboy models with top or right sideventing

• Downflow/Horizontal model fieldconvertible from Downflow to right or lefthorizontal

• 6” Left and Right side fresh air knockouts –Highboy and Lowboy Models

• Barometric draft regulator included

Page 89: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

FUR-15 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

PHASED OUT

Upflow/Horizontal90% Gas Furnace Quick Reference

Specifications:Furnace Nom. Blower Flue Propane Outlet Return AirModel BTUH ICS11111 Max.22222 Speed Motor Size Conversion Air Bottom SideNumber22222 Output AFUE Airflow Taps H.P. (in.) Kit W D W D H D

1 Isolated Combustion System.2 CFM @ .5 inches ESP with filter in place.

UPFLOW/HORIZONTAL — XV 90 VARIABLE SPEED WITH RECUPERATIVE CELL DIRECT/NON DIRECT VENT TWO-STAGETUY060R9V3W 56,000 93.0 1275 Var. Var. 2–3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUY080R9V3W 73,000 92.5 1400 Var. Var. 2–3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUY100R9V4W 93,000 93.0 1770 Var. Var. 21/2–3 BAYLPKT210B 19.75 19.6 19 23.5 14.88 23.75TUY120R9V5W 112,000 92.5 1920 Var. Var. 3 Only BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75UPFLOW/HORIZONTAL — XL 90 DIRECT/NON-DIRECT VENT, TWO STAGE, 1 OR 2 PIPE, UPFLOW/HORIZONTAL CONDENSING GAS FURNACETUX060R936W 56,000 93.0 1196 4 1/3 2–3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUX080R942W 73,000 92.5 1470 4 1/3 2–3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUX100R948W 93,000 93.0 1746 4 1/2 21/2–3 BAYLPKT210B 19.75 19.6 19 23.5 14.88 23.75TUX120R960W 112,000 92.5 2261 4 3/4 3 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75UPFLOW/ HORIZONTAL- XT 90 DIRECT/NON-DIRECT VENT, SINGLE-STAGE, ONE OR TWO PIPE, CONDENSING GAS FURNACE (115/1/60)TUX1B040A9H21A 38,000 92.1 1052 4 1/2 2, 21/2, 3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUX1B060A9H31A 56,000 92.1 1248 4 1/2 2, 21/2, 3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUX1B080A9H31A 74,000 92.1 1320 4 1/2 2, 21/2, 3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUX1C100A9H41A 94,000 92.1 1737 4 3/4 21/2, 3 BAYLPKT210B 19.75 19.6 19 23.5 14.88 23.75TUX1D120A9H51A 113,000 92.1 2023 4 1.0 21/2, 3 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75UPFLOW/ HORIZONTAL- XR 90 DIRECT/NON-DIRECT VENT, SINGLE-STAGE, ONE OR TWO PIPE, CONDENSING GAS FURNACE (115/1/60)TUX1B040A9241A 38,000 92.1 812 4 1/5 2–3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUX1B060A9361A 56,000 92.1 1196 4 1/3 2–3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUX1B080A9421A 74,000 92.1 1470 4 1/3 2–3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUX1B080A9601A 76,000 92.1 2121 4 1/2 2–3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUX1C100A9481A 94,000 92.1 1746 4 1/2 21/2–3 BAYLPKT210B 19.75 19.6 19 23.5 14.88 23.75TUX1C100A9601A 93,000 92.1 2165 4 1/2 21/2–3 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75TUX1D120A9601A 113,000 92.1 2261 4 1/2 3 Only BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75UPFLOW/HORIZONTAL — XB 90 WITH RECUPERATIVE COIL SINGLE STAGETUC040C924B 37,000 92.1 812 4 1/5 21/2–3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUC060C936B 56,000 92.1 1196 4 1/3 21/2–3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUC080C942B 74,000 92.1 1470 4 1/3 21/2–3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUC100C948B 94,000 92.1 1746 4 1/2 21/2–3 BAYLPKT210B 19.75 19.6 19 23.5 14.88 23.75TUC100C960B 93,000 92.1 2165 4 1/2 21/2–3 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75TUC120C960B 113,000 92.1 2261 4 1/2 3 Only BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75UPFLOW/HORIZONTAL — XR 90 WITH RECUPERATIVE COIL DIRECT/NON DIRECT VENT SINGLE STAGETUX040C924D 38,000 92.1 812 4 1/5 2–3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUX060C936D 56,000 92.1 1196 4 1/3 2–3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUX080C942D 74,000 92.1 1470 4 1/3 2–3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUX080C960D 76,000 92.1 2121 4 1/2 2–3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUX100C948D 94,000 92.1 1746 4 1/2 21/2–3 BAYLPKT210B 19.75 19.6 19 23.5 14.88 23.75TUX100C960D 93,000 92.1 2165 4 1/2 21/2–3 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75TUX120C960D 113,000 92.1 2261 4 1/2 3 Only BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75

Page 90: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

FUR-16Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

PHASED OUT

Specifications:Furnace Nom. Blower Flue Propane Outlet ReturnModel BTUH ICS11111 Max.2 Speed Motor Size Conversion Downflow Air AirNumber Output AFUE Airflow Taps H.P. (in.) Kit Subbase W D H D

DOWNFLOW/HORIZONTAL — XV 90 VARIABLE SPEED WITH RECUPERATIVE CELL DIRECT VENT TWO-STAGETDY060R9V3W 56,000 92.0 1350 Var. Var. 2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDY080R9V3W 74,000 92.5 1210 Var. Var. 2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDY100R9V4W 94,000 93.0 1800 Var. Var. 21/2–3 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6TDY120R9V5W 112,000 92.5 1900 Var. Var. 3 Only BAYLPKT210B BAYBASE205 23 19.6 23.25 19.6DOWNFLOW/HORIZONTAL— XL 90 NON-DIRECT VENT, TWO STAGE, ONE OR TWO PIPE, CONDENSING GAS FURNACETDX060R936W 55,000 92.0 1209 4 1/3 2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDX080R942W 74,000 92.5 1323 4 1/2 2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDX100R948W 93,000 93.0 1614 4 1/2 21/2–3 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6TDX120R960W 111,000 92.5 1939 4 3/4 3 BAYLPKT210B BAYBASE205 23 19.6 23.25 19.6DOWNFLOW/ HORIZONTAL- XT 90 DIRECT/NON-DIRECT VENT, SINGLE-STAGE, ONE OR TWO PIPE, CONDENSING GAS FURNACETDX1B040A9H31A 38,000 91.0 1043 4 1/2 2, 21/2, 3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDX1B060A9H31A 56,000 91.0 1223 4 1/2 2, 21/2, 3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDX1B080A9H31A 74,000 91.0 1423 4 3/4 2, 21/2, 3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDX1C100A9H41A 94,000 91.0 1700 4 3/4 21/2, 3 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6TDX1D120A9H51A 112,000 91.0 2006 4 1.0 21/2, 3 BAYLPKT210B BAYBASE205 23 19.6 23.25 19.6DOWNFLOW/ HORIZONTAL- XR 90 DIRECT/NON-DIRECT VENT, SINGLE-STAGE, ONE OR TWO PIPE, CONDENSING GAS FURNACETDX1B040A9241A 38,000 91.0 807 4 1/5 2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDX1B060A9361A 56,000 91.0 1209 4 1/3 2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDX1B080A9421A 74,000 91.0 1323 3 1/2 2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDX1C100A9481A 94,000 91.0 1614 3 1/2 21/2–3 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6TDX1D120A9601A 112,000 91.0 1939 3 1/2 3 Only BAYLPKT210B BAYBASE205 23 19.6 23.25 19.6DOWNFLOW/HORIZONTAL — XB 90 WITH RECUPERATIVE COIL SINGLE STAGETDC040C924B 38,000 91.0 807 4 1/5 21/2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDC060C936B 56,000 91.0 1082 4 1/3 2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDC080C942B 74,000 91.0 1323 3 1/2 2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDC100C948B 93,000 91.0 1614 3 1/2 2–3 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6TDC120C960B 112,000 91.0 1939 3 1/2 3 Only BAYLPKT210B BAYBASE205 23.0 19.6 23.25 19.6DOWNFLOW/HORIZONTAL — XR 90 WITH RECUPERATIVE COIL DIRECT VENT SINGLE STAGETDX040C924D 38,000 91.0 807 4 1/5 2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDX060C936D 56,000 91.0 1209 4 1/3 2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDX080C942D 74,000 91.0 1323 3 1/2 2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDX100C948D 94,000 91.0 1614 3 1/2 21/2–3 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6TDX120C960D 112,000 91.0 1939 3 1/2 3 Only BAYLPKT210B BAYBASE205 23 19.6 23.25 19.6

1 Isolated Combustion System.2 CFM @ .5 inches ESP with filter in place.

Downflow/Horizontal90% Gas Furnace Quick Reference

Page 91: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

FUR-17 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

PHASED OUT

Upflow/Horizontal80% Gas Furnace Quick Reference

Specifications:Furnace Nom. Blower Flue Propane Outlet Return AirModel BTUH ICS11111 Max.22222 Speed Motor Size Conversion Air Bottom SideNumber22222 Output AFUE Airflow Taps H.P. (in.) Kit W D W D H D

UPFLOW/HORIZONTAL — XV 80 VARIABLE SPEED TWO-STAGETUD060R9V3K 48,000 80.0 1402 Var. Var. 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD080R9V3K 64,000 80.0 1410 Var. Var. 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD080R9V4K 64,000 80.0 1591 Var. Var. 4 BAYLPKT210B 19.75 19.6 19.5 23.5 14.88 23.75TUD100R9V3K 80,000 80.0 1251 Var. Var. 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD100R9V5K 79,000 80.0 2100 Var. Var. 4 BAYLPKT210B 19.75 19.6 19 23.5 14.88 23.75TUD120R9V5K 97,000 80.0 2019 Var. Var. 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75TUD140R9V5K 112,000 80.0 2075 Var. Var. 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75UPFLOW/HORIZONTAL — XL 80 INDUCED DRAFT TWO-STAGETUD040R924K 32,000 80.0 910 4 1/5 4 BAYLPKT210B 13.25 19.6 13 23.5 14.88 23.75TUD060R936K 47,000 80.0 1236 4 1/3 4 BAYLPKT210B 13.25 19.6 13 23.5 14.88 23.75TUD060R937K 47,000 80.0 1296 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD080R936K 63,000 80.0 1296 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD080R948K 63,000 80.0 1710 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD100R936K 79,000 80.0 1363 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD100R948K 79,000 80.0 1669 4 1/2 4 BAYLPKT210B 19.75 19.6 19.5 23.5 14.88 23.75TUD100R960K 80,000 80.0 1978 4 1/2 4 BAYLPKT210B 19.75 19.6 23 23.5 14.88 23.75TUD100R961K 80,000 80.0 2175 4 1/2 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75TUD120R954K 95,000 80.0 2037 4 1/2 4 BAYLPKT210B 19.75 19.6 19.5 23.5 14.88 23.75TUD120R960K 95,000 80.0 2005 4 1/2 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75TUD140R960K 112,000 80.0 2216 4 3/4 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75UPFLOW/ HORIZONTAL- XT 80 DIRECT/NON-DIRECT VENT, SINGLE-STAGE, ONE OR TWO PIPE, CONDENSING GAS FURNACETUD1A040A9H21A 32,000 80.0 1011 4 1/2 4 BAYLPKT210B 13.25 19.6 13 23.5 14.88 23.75TUD1B060A9H31A 47,000 80.0 1238 4 1/2 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD1B080A9H31A 63,000 80.0 1318 4 1/2 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD1C080A9H41A 64,000 80.0 1600 4 3/4 4 BAYLPKT210B 19.75 19.6 19.5 23.5 14.88 23.75TUD1B100A9H31A 79,000 80.0 1280 4 3/4 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD1C100A9H51A 79,000 80.0 2038 4 1.0 4 BAYLPKT210B 19.25 19.6 19.5 23.5 14.88 23.75TUD1D120A9H51A 96,000 80.0 1996 4 1.0 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75TUD1D140A9H51A 111,000 80.0 1984 4 1.0 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75UPFLOW/ HORIZONTAL- XR 80 DIRECT/NON-DIRECT VENT, SINGLE-STAGE, ONE OR TWO PIPE, CONDENSING GAS FURNACETUD1A040A9241A 32,000 80.0 910 4 1/5 4 BAYLPKT210B 13.25 19.6 13 23.5 14.88 23.75TUD1A040A9301A 32,000 80.0 1092 4 1/3 4 BAYLPKT210B 13.25 19.6 13 23.5 14.88 23.75TUD1A060A9241A 47,000 80.0 901 4 1/5 4 BAYLPKT210B 13.25 19.6 13 23.5 14.88 23.75TUD1A060A9361A 47,000 80.0 1236 4 1/3 4 BAYLPKT210B 13.25 19.6 13 23.5 14.88 23.75TUD1B060A9361A 47,000 80.0 1296 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD1B080A9241A 64,000 80.0 956 4 1/5 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD1B080A9361A 63,000 80.0 1296 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD1B080A9481A 64,000 80.0 1710 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD1C080A9601A 64,000 80.0 2163 4 3/4 4 BAYLPKT210B 16.25 19.6 19.5 23.5 14.88 23.75TUD1B100A9361A 79,000 80.0 1363 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD1B100A9451A 80,000 80.0 1556 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.55TUD1C100A9481A 79,000 80.0 1669 4 1/2 4 BAYLPKT210B 19.75 19.6 19.5 23.5 14.88 23.75TUD1C100A9601A 79,000 80.0 2001 4 1/2 4 BAYLPKT210B 19.75 19.6 23 23.5 14.88 23.75TUD1D100A9721A 80,000 80.0 2249 4 3/4 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75TUD1C120A9541A 96,000 80.0 2037 4 1/2 4 BAYLPKT210B 19.75 19.6 19.5 23.5 14.88 23.75TUD1D120A9601A 96,000 80.0 2005 4 1/2 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75TUD1D140A9601A 111,000 80.0 2216 4 3/4 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75UPFLOW/HORIZONTAL— XB 80 INDUCED DRAFT SINGLE STAGETUE040A924L 31,000 80.0 910 4 1/5 4 BAYLPKT210B 13.25 19.6 13 23.5 14.88 23.75TUE060A936L 47,000 80.0 1296 4 1/3 4 BAYLPKT210B 13.25 19.6 13 23.5 14.88 23.75TUE060A937L 47,000 80.0 1296 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUE080A936L 63,000 80.0 1296 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUE080A948L 64,000 80.0 1710 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUE100A936L 79,000 80.0 1363 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUE100A948L 79,000 80.0 1669 4 1/2 4 BAYLPKT210B 19.25 19.6 19.5 23.5 14.88 23.75TUE100A960L 79,000 80.0 2001 4 1/2 4 BAYLPKT210B 19.75 19.6 19.5 23.5 14.88 23.75TUE120A960L 96,000 80.0 2005 4 1/2 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75TUE140A960L 111,000 80.0 2216 4 3/4 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75UPFLOW/HORIZONTAL — XR 80 INDUCED DRAFT SINGLE STAGETUD040C924K 32,000 80.0 910 4 1/5 4 BAYLPKT210B 13.25 19.6 13 23.5 14.88 23.75TUD040C930K 32,000 80.0 1092 4 1/3 4 BAYLPKT210B 13.25 19.6 13 23.5 14.88 23.75TUD060C924K 47,000 80.0 901 4 1/5 4 BAYLPKT210B 13.25 19.6 13 23.5 14.88 23.75TUD060C936K 47,000 80.0 1236 4 1/3 4 BAYLPKT210B 13.25 19.6 13 23.5 14.88 23.75TUD060C937K 47,000 80.0 1296 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD080C924K 64,000 80.0 956 4 1/5 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD080C936K 63,000 80.0 1296 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD080C948K 64,000 80.0 1710 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD080C960K 64,000 80.0 2163 4 3/4 4 BAYLPKT210B 16.25 19.6 19.5 23.5 14.88 23.75TUD100C936K 79,000 80.0 1363 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD100C945K 80,000 80.0 1556 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.55TUD100C948K 79,000 80.0 1669 4 1/2 4 BAYLPKT210B 19.75 19.6 19.5 23.5 14.88 23.75TUD100C960K 79,000 80.0 2001 4 1/2 4 BAYLPKT210B 19.75 19.6 23 23.5 14.88 23.75TUD100C972K 80,000 80.0 2249 4 3/4 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75TUD120C954K 96,000 80.0 2037 4 1/2 4 BAYLPKT210B 19.75 19.6 19.5 23.5 14.88 23.75TUD120C960K 96,000 80.0 2005 4 1/2 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75TUD140C960K 111,000 80.0 2216 4 3/4 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75

1 Isolated Combustion System. 2 CFM @ .5 inches ESP with filter in place.

Page 92: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

FUR-18Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

PHASED OUT

Specifications:Furnace Nom. Blower Flue Propane Outlet ReturnModel BTUH ICS11111 Max.2 Speed Motor Size Conversion Downflow Air AirNumber Output AFUE Airflow Taps H.P. (in.) Kit Subbase W D H D

DOWNFLOW/HORIZONTAL — XV 80 VARIABLE SPEED TWO STAGETDD060R9V3F 48,000 80.0 1360 Var. Var. 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDD080R9V3F 63,000 80.0 1315 Var. Var. 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDD100R9V5F 81,000 80.0 2015 Var. Var. 4 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6TDD120R9V5F 95,000 80.0 2215 Var. Var. 4 BAYLPKT210B BAYBASE205 23 19.6 23.25 19.6DOWNFLOW/HORIZONTAL — XL 80 TWO-STAGE INDUCED DRAFTTDD040R924F 32,000 80.0 960 4 1/5 4 BAYLPKT210B BAYBASE205 13 19.6 13.25 19.6TDD060R936F 47,000 80.0 1282 4 1/3 4 BAYLPKT210B BAYBASE205 13 19.6 13.25 19.6TDD060R937F 47,000 80.0 1369 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDD080R936F 64,000 80.0 1369 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDD100R945F 79,000 80.0 1546 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDD100R948F 79,000 80.0 1740 4 1/2 4 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6TDD100R960F 81,000 80.0 1929 4 1/2 4 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6TDD120R960F 94,000 80.0 2049 4 1/2 4 BAYLPKT210B BAYBASE205 23 19.6 23.25 19.6TDD140R960F 113,000 80.0 2133 4 3/4 4 BAYLPKT210B BAYBASE205 23 19.6 23.25 19.6DOWNFLOW/ HORIZONTAL- XT 80 DIRECT/NON-DIRECT VENT, SINGLE-STAGE, ONE OR TWO PIPE, CONDENSING GAS FURNACETDD1B060A9H31A 48,000 80.0 1309 4 1/2 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDD1B080A9H31A 64,000 80.0 1314 4 1/2 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDD1C100A9H51A 81,000 80.0 2007 4 1.0 4 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6TDD1D120A9H51A 96,000 80.0 2010 4 1.0 4 BAYLPKT210B BAYBASE205 23 19.6 23.25 19.6DOWNFLOW/ HORIZONTAL- XR 80 DIRECT/NON-DIRECT VENT, SINGLE-STAGE, ONE OR TWO PIPE, CONDENSING GAS FURNACETDD1A040A9241A 31,000 78.0 920 4 1/5 4 BAYLPKT210B BAYBASE205 13 19.6 13.25 19.6TDD1A060A9241A 48,000 80.0 1001 4 1/5 4 BAYLPKT210B BAYBASE205 13 19.6 13.25 19.6TDD1A060A9361A 48,000 80.0 1282 4 1/3 4 BAYLPKT210B BAYBASE205 13 19.6 13.25 19.6TDD1B060A9361A 48,000 80.0 1369 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDD1B080A9361A 64,000 80.0 1369 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDD1B080A9451A 64,000 80.0 1575 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDD1B100A9451A 80,000 80.0 1546 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDD1C100A9481A 80,000 80.0 1740 4 1/2 4 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6TDD1C100A9541A 81,000 80.0 1929 4 1/2 4 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6TDD1C120A9541A 96,000 80.0 1918 4 1/2 4 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6TDD1D120A9601A 96,000 80.0 2049 4 1/2 4 BAYLPKT210B BAYBASE205 23 19.6 23.25 19.6TDD1D140A9601A 113,000 80.0 2133 4 3/4 4 BAYLPKT210B BAYBASE205 23 19.6 23.25 19.6DOWNFLOW/HORIZONTAL — XB 80 INDUCED DRAFT SINGLE STAGETDE060A936M 48,000 80.0 1282 4 1/3 4 BAYLPKT210B BAYBASE205 13 19.6 13.25 19.6TDE060A937M 48,000 80.0 1281 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDE080A945M 64,000 80.0 1575 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDE100A945M 80,000 80.0 1546 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDE100A960M 81,000 80.0 1929 4 1/2 4 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6TDE120A960M 96,000 80.0 2049 4 1/2 4 BAYLPKT210B BAYBASE205 23 19.6 23.25 19.6DOWNFLOW/HORIZONTAL — XR 80 INDUCED DRAFT SINGLE STAGETDD040C924F 31,000 78.0 920 4 1/5 4 BAYLPKT210B BAYBASE205 13 19.6 13.25 19.6TDD060C924F 48,000 80.0 1001 4 1/5 4 BAYLPKT210B BAYBASE205 13 19.6 13.25 19.6TDD060C936F 48,000 80.0 1282 4 1/3 4 BAYLPKT210B BAYBASE205 13 19.6 13.25 19.6TDD060C937F 48,000 80.0 1369 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDD080C936F 64,000 80.0 1369 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDD080C945F 64,000 80.0 1575 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDD100C945F 80,000 80.0 1546 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6TDD100C948F 80,000 80.0 1740 4 1/2 4 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6TDD100C954F 81,000 80.0 1929 4 1/2 4 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6TDD120C954F 96,000 80.0 1918 4 1/2 4 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6TDD120C960F 96,000 80.0 2049 4 1/2 4 BAYLPKT210B BAYBASE205 23 19.6 23.25 19.6TDD140C960F 113,000 80.0 2133 4 3/4 4 BAYLPKT210B BAYBASE205 23 19.6 23.25 19.6

1 Isolated Combustion System.2 CFM @ .5 inches ESP with filter in place.

Downflow/Horizontal80% Gas Furnace Quick Reference

Page 93: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

FUR-19 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

High EfficiencySplit System – CasedHeat Pump and Cooling Coils

Table FUR-19-A — Aluminum High Efficiency Coils (Upflow/Downflow/Horizontal Left) R-22 RefrigerantNom. Cap. Outlet Overall Shipping Line Size

Model Cooling Coil Refrigerant Dim. (in.) Dim. (in.) Weight OD ODNumber (Btuh) Type Control W/H x D H x W x D (Ibs.) Gas Liq.

2TXCB025AS3HCA 30,000 A TXV-NB1 155/8 x 193/8 17.5 x 17.5 x 21.5 42 5/8 3/82TXCB031AS3HCA 30,000 A TXV-NB1 155/8 x 193/8 22.5 x 17.5 x 21.5 54 7/8 3/82TXCB036AS3HCA 36,000 A TXV-NB1 155/8 x 193/8 26.88 x 17.5 x 21.5 67 7/8 3/82TXCC037AS3HCA 36,000 A TXV-NB1 191/8 x 193/8 26.88 x 21 x 21.5 70 7/8 3/82TXCC054AS3HCA 54,000 A TXV-NB1 191/8 x 193/8 30 x 21 x 21.5 73 11/8 3/82TXCD065AS3HCA 60,000 A TXV-NB1 225/8 x 193/8 33* x 24.5 x 21.5 90 11/8 3/8

Table FUR-19-B — Aluminum High Efficiency Coils (Upflow/Downflow/Horizontal Left) R-410A RefrigerantNom. Cap. Outlet Overall Shipping Line Size

Model Cooling Coil Refrigerant Dim. (in.) Dim. (in.) Weight OD ODNumber (Btuh) Type Control W/H x D H x W x D (Ibs.) Gas Liq.

4TXCB025AS3HCA 30,000 A TXV-NB1 155/8 x 193/8 17.5 x 17.5 x 21.5 42 5/8 3/84TXCB031AS3HCA 30,000 A TXV-NB1 155/8 x 193/8 22.5 x 17.5 x 21.5 54 7/8 3/84TXCB036AS3HCA 36,000 A TXV-NB1 155/8 x 193/8 26.88 x 17.5 x 21.5 67 7/82 3/84TXCC037AS3HCA 36,000 A TXV-NB1 191/8 x 193/8 26.88 x 21 x 21.5 70 7/8 3/84TXCC054AS3HCA 54,000 A TXV-NB1 191/8 x 193/8 30 x 21 x 21.5 73 11/83 3/84TXCD065AS3HCA 60,000 A TXV-NB1 225/8 x 193/8 33* x 24.5 x 21.5 90 11/83 3/8

Table FUR-19-C —Cased Horizontal Flat Coil R-22 RefrigerantNom. Cap. Outlet Overall Shipping Line Size

Model Cooling Coil Refrigerant Dim. (in.) Dim. (in.) Weight OD ODNumber (Btuh) Type Control W/H x D H x W x D (Ibs.) Gas Liq.

2TXFH018AS3HHA 18,000 Flat TXVNB1 24 x 21 22 x 10 x 28 40 5/8 1/42TXFH033AS3HHA 34,000 Flat TXVNB1 24 x 21 22 x 10 x 28 46 3/4 5/16

2TXFH041AS3HHA 44,000 Flat TXVNB1 331/4 x 21 22 x 10 x 37 56 7/8 3/82TXFH054AS3HHA 58,000 Flat TXVNB1 331/4 x 21 22 x 10 x 37 64 11/8 3/82TXFH063AS3HHA 61,000 Flat TXVNB1 331/4 x 27 28 x 10 x 37 79 11/8 3/8

Table FUR-19-D —Cased Horizontal Flat Coil R-410A RefrigerantNom. Cap. Outlet Overall Shipping Line Size

Model Cooling Coil Refrigerant Dim. (in.) Dim. (in.) Weight OD ODNumber (Btuh) Type Control W/H x D H x W x D (Ibs.) Gas Liq.

4TXFH018AS3HHA 18,000 Flat TXVNB1 24 x 21 22 x 10 x 28 40 1/2 1/44TXFH033AS3HHA 34,000 Flat TXVNB1 24 x 21 22 x 10 x 28 46 3/4 5/16

4TXFH041AS3HHA 44,000 Flat TXVNB1 331/4 x 21 22 x 10 x 37 56 3/4 3/84TXFH054AS3HHA 58,000 Flat TXVNB1 331/4 x 21 22 x 10 x 37 64 7/8 3/84TXFH063AS3HHA 61,000 Flat TXVNB1 331/4 x 27 28 x 10 x 37 79 7/8 3/8

Table FUR-19-E — Reversible, Cased Heat Pump/Cooling Coils — (Upflow/Downflow Horizontal Leftor Right) R-22 Refrigerant

Nom. Cap. Maximum Outlet Overall Shipping Line SizeModel Cooling Cooling Coil Refrigerant Dim. (in.) Dim. (in.) Weight OD ODNumber (Btuh) (CFM**) Type Control W/H x D H x W x D (Ibs.) Gas Liq.

2TXCA024AC3HMA 24,000 1000 A TXVNB1 125/8 x 193/8 30 x 14.5 x 21.5 1000 3/4 5/16

2TXCB036AC3HMA 36,000 1200 A TXVNB1 155/8 x 193/8 30 x 17.5 x 21.5 1200 7/8 3/81 Start Kits may be required on outdoor unit.2 7/8 x 3/4 reducing coupling shipped with R-410A model coil.3 11/8 x 7/8 reducing coupling shipped with R-410A model coil.*Overall height. Actual height of case is 30".**Water Blowoff may occur if Maximum Cooling airflow is exceeded.

• All Aluminium coil to reduceformicary corrosion

• All Non-Bleed TXV valveswith internal check valve forheat pump operation

• Split inner and outer doorsfor easy coil cleaning

• Double sloped non corrosivedrain pans- UL Rated 400°F

• Suction pressure serviceport

• 100% foil faced insulation• Easy case attachment to

furnace• 3 way application• Painted cabinet matches

furnace• 10 Year limited parts

warranty on all Aluminiumcoils

Comfort TM coil

2/4TXC Comfort™Coil Features:

UP

DOWN

LEFT 3 WAY COIL

TXF Features:• Bi-directional airflow• Sloped non corrosive drain pan• HP TXV with mechanical

fittings• Galvanized steel cabinet• 100% foil lined insulation

Reversible Features:• Bi-Directional Airflow• Same side service access for

Horizontal Right or Leftapplications

• Eliminates need for fieldinstalled Horizontal DripTray!!!

• Fully Convertible - Upflow,Downflow, Left or Right

• Heat Pump and CoolingCompatible

• Suction service port• 100% foil lined insulation• Split inner and outer doors for

easy coil cleaning• Double sloped non-corrosive

drain pan - UL rated 400°F• 5 year limited parts warranty

on all coils• Non-Bleed TXV with

mechanical fittings

AIRFLOW

FURNACE

AIRFLOW

FURNACE

Page 94: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

FUR-20Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Split System – CasedHeat Pump and Cooling Coils

Table FUR-20-A — Cased Coil Convertible (Upflow/ Downflow/ Horizontal Left) R-22 RefrigerantNom. Cap. Outlet Overall Shipping Line Size

Model Cooling Coil Refrigerant Dim. (in.) Dim. (in.) Weight OD ODNumber (Btuh) Type Control W/H x D H x W x D (Ibs.) Gas Liq.

2TXCA018AC3HCA 18,000 A TXVNB1 125/8 x 193/8 17.6 x 14.5 x 21.5 34 5/8 1/42TXCA024AC3HCA 24,000 A TXVNB1 125/8 x 193/8 22.6 x 14.5 x 21.5 37 3/4 5/16

2TXCB025AC3HCA 24,000 A TXVNB1 155/8 x 193/8 17.6 x 17.5 x 21.5 42 3/4 5/16

2TXCB031AC3HCA 30,000 A TXVNB1 155/8 x 193/8 17.6 x 17.5 x 21.5 46 3/4 5/16

2TXCB036AC3HCA 36,000 A TXVNB1 155/8 x 193/8 22.6 x 17.5 x 21.5 54 7/8 3/82TXCC037AC3HCA 37,000 A TXVNB1 191/8 x 193/8 22.6 x 21 x 21.5 53 7/8 3/82TXCB042AC3HCA 42,000 A TXVNB1 155/8 x 193/8 22.6 x 17.5 x 21.5 59 7/8 3/82TXCC043AC3HCA 43,000 A TXVNB1 191/8 x 193/8 22.6 x 21 x 21.5 56 11/8 3/82TXCB048AC3HCA 48,000 A TXVNB1 155/8 x 193/8 26.9 x 17.5 x 21.5 71 11/8 3/82TXCC049AC3HCA 48,000 A TXVNB1 191/8 x 193/8 26.9 x 21 x 21.5 67 11/8 3/82TXCD050AC3HCA 48,000 A TXVNB1 225/8 x 193/8 26.9 x 24.5 x 21.5 77 11/8 3/82TXCC060AC3HCA 60,000 A TXVNB1 191/8 x 193/8 30.1 x 21 x 21.5 74 11/8 3/82TXCD061AC3HCA 60,000 A TXVNB1 225/8 x 193/8 30.1 x 24.5 x 21.5 77 11/8 3/8

Table FUR-20-B — Cased Coil Convertible (Upflow/ Downflow/ Horizontal Left) R-410A RefrigerantNom. Cap. Outlet Overall Shipping Line Size

Model Cooling Coil Refrigerant Dim. (in.) Dim. (in.) Weight OD ODNumber (Btuh) Type Control W/H x D H x W x D (Ibs.) Gas Liq.4TXCA018AC3HCA 18,000 A TXVNB1 125/8 x 193/8 17.6 x 14.5 x 21.5 34 5/8 1/44TXCA024AC3HCA 24,000 A TXVNB1 125/8 x 193/8 22.6 x 14.5 x 21.5 37 3/4 5/16

4TXCB025AC3HCA 24,000 A TXVNB1 155/8 x 193/8 17.6 x 17.5 x 21.5 42 3/4 5/16

4TXCB031AC3HCA 30,000 A TXVNB1 155/8 x 193/8 17.6 x 17.5 x 21.5 46 3/4 5/16

4TXCB036AC3HCA 36,000 A TXVNB1 155/8 x 193/8 22.6 x 17.5 x 21.5 54 7/8 3/84TXCC037AC3HCA 37,000 A TXVNB1 191/8 x 193/8 22.6 x 21 x 21.5 53 7/8 3/84TXCB042AC3HCA 42,000 A TXVNB1 155/8 x 193/8 22.6 x 17.5 x 21.5 59 7/8 3/84TXCC043AC3HCA 43,000 A TXVNB1 191/8 x 193/8 22.6 x 21 x 21.5 56 11/8 3/84TXCB048AC3HCA 48,000 A TXVNB1 155/8 x 193/8 26.9 x 17.5 x 21.5 71 11/8 3/84TXCC049AC3HCA 48,000 A TXVNB1 191/8 x 193/8 26.9 x 21 x 21.5 67 11/8 3/84TXCD050AC3HCA 48,000 A TXVNB1 225/8 x 193/8 26.9 x 24.5 x 21.5 77 11/8 3/84TXCC060AC3HCA 60,000 A TXVNB1 191/8 x 193/8 30.1 x 21 x 21.5 74 11/8 3/84TXCD061AC3HCA 60,000 A TXVNB1 225/8 x 193/8 30.1 x 24.5 x 21.5 77 11/8 3/8

Comfort TM coil

TXC Comfort™Coil Features:• HP TXV Mechanical

Fittings (2/4 TXC)• Split inner and outer doors

for easy coil cleaning• Double sloped non

corrosive drain pans-UL Rated 400°F

• Suction pressure serviceport

• 100% foil lined insulation• Easy case attachment to

furnace• 3 way application• Painted cabinet matches

furnace• 5 year limited parts

warranty• Copper tube Aluminum fin

2/4CXC Coil Features:• Cased and uncased

upflow /downflow coolingonly coils

• Brazed fittings (left side)• Drain fitting (left side)• Non-Bleed TXV with

mechanical fittings.• Copper tube with

Aluminum fins• Painted coil case• Suction pressure service

port• 100% foil lined insulation• Split inner and outer doors

for easy coil cleaning• 5 Year limited parts

warranty

Comfort TM coil

Split System – CasedCooling Only Coils

Table FUR-20-C — Cooling Only Cased (Upflow/ Downflow) R-22 RefrigerantNom. Cap. Outlet Overall Shipping Line Size

Model Cooling Coil Refrigerant Dim. (in.) Dim. (in.) Weight OD ODNumber (Btuh) Type Control W/H x D H x W x D (Ibs.) Gas Liq.

2CXCA018AC3CUA 18,000 A TXVNB1 125/8 x 193/8 17.6 x 14.5 x 21.5 32 5/8 1/42CXCA024AC3CUA 24,000 A TXVNB1 125/8 x 193/8 22.6 x 14.5 x 21.5 34 3/4 5/16

2CXCB025AC3CUA 24,000 A TXVNB1 155/8 x 193/8 17.6 x 17.5 x 21.5 42 3/4 5/16

2CXCB031AC3CUA 30,000 A TXVNB1 155/8 x 193/8 17.6 x 17.5 x 21.5 44 3/4 5/16

2CXCB036AC3CUA 36,000 A TXVNB1 155/8 x 193/8 22.6 x 17.5 x 21.5 44 7/8 3/82CXCC037AC3CUA 37,000 A TXVNB1 191/8 x 193/8 22.6 x 21 x 21.5 53 7/8 3/82CXCB042AC3CUA 42,000 A TXVNB1 155/8 x 193/8 22.6 x 17.5 x 21.5 52 7/8 3/82CXCC043AC3CUA 43,000 A TXVNB1 191/8 x 193/8 22.6 x 21 x 21.5 56 11/8 3/82CXCB048AC3CUA 48,000 A TXVNB1 155/8 x 193/8 26.9 x 17.5 x 21.5 58 11/8 3/82CXCC049AC3CUA 48,000 A TXVNB1 191/8 x 193/8 26.9 x 21 x 21.5 67 11/8 3/82CXCD050AC3CUA 48,000 A TXVNB1 225/8 x 193/8 26.9 x 24.5 x 21.5 77 11/8 3/82CXCC060AC3CUA 60,000 A TXVNB1 191/8 x 193/8 30.1 x 21 x 21.5 70 11/8 3/82CXCD061AC3CUA 60,000 A TXVNB1 225/8 x 193/8 30.1 x 24.5 x 21.5 72 11/8 3/8

1 Start Kits may be required on outdoor unit.

Page 95: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

FUR-21 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Table FUR-21-A — Cooling Only Cased (Upflow/ Downflow) R-410A RefrigerantNom. Cap. Outlet Overall Shipping Line Size

Model Cooling Coil Refrigerant Dim. (in.) Dim. (in.) Weight OD ODNumber (Btuh) Type Control W/H x D H x W x D (Ibs.) Gas Liq.

4CXCA018AC3CUA 18,000 A TXVNB1 125/8 x 193/8 17.6 x 14.5 x 21.5 32 5/8 1/44CXCA024AC3CUA 24,000 A TXVNB1 125/8 x 193/8 22.6 x 14.5 x 21.5 34 3/4 5/16

4CXCB025AC3CUA 24,000 A TXVNB1 155/8 x 193/8 17.6 x 17.5x 21.5 42 3/4 5/16

4CXCB031AC3CUA 30,000 A TXVNB1 155/8 x 193/8 17.6 x 17.5 x 21.5 44 3/4 5/16

4CXCB036AC3CUA 36,000 A TXVNB1 155/8 x 193/8 22.6 x 17.5 x 21.5 44 7/8 3/84CXCC037AC3CUA 37,000 A TXVNB1 191/8 x 193/8 22.6 x 21 x 21.5 53 7/8 3/84CXCB042AC3CUA 42,000 A TXVNB1 155/8 x 193/8 22.6 x 17.5 x 21.5 52 7/8 3/84CXCC043AC3CUA 43,000 A TXVNB1 191/8 x 193/8 22.6 x 21 x 21.5 56 11/8 3/84CXCB048AC3CUA 48,000 A TXVNB1 155/8 x 193/8 26.9 x 17.5 x 21.5 58 11/8 3/84CXCC049AC3CUA 48,000 A TXVNB1 191/8 x 193/8 26.9 x 21 x 21.5 67 11/8 3/84CXCD050AC3CUA 48,000 A TXVNB1 225/8 x 193/8 26.9 x 24.5 x 21.5 77 11/8 3/84CXCC060AC3CUA 60,000 A TXVNB1 191/8 x 193/8 30.1 x 21 x 21.5 70 11/8 3/84CXCD061AC3CUA 60,000 A TXVNB1 225/8 x 193/8 30.1 x 24.5 x 21.5 72 11/8 3/8

Table FUR-21-B — Cooling Only Uncased Coils (Upflow/ Downflow) R-22 RefrigerantNom. Cap. Overall Shipping Line Size

Model Cooling Coil Refrigerant Dim. (in.) Weight OD ODNumber (Btuh) Type Control H x W x D (Ibs.) Gas Liq.

2CXAA018AC3CUA 18,000 A TXVNB1 15.9 x 13.3 x 21.1 17 5/8 1/42CXAA024AC3CUA 24,000 A TXVNB1 17.6 x 13.3 x 21.1 20 3/4 5/16

2CXAB025AC3CUA 24,000 A TXVNB1 15.9 x 16.3 x 21.1 21 3/4 5/16

2CXAB031AC3CUA 30,000 A TXVNB1 15.9 x 16.3 x 21.1 26 3/4 5/16

2CXAB036AC3CUA 36,000 A TXVNB1 21.2 x 16.3 x 21.1 26 7/8 3/82CXAB042AC3CUA 42,000 A TXVNB1 21.2 x 16.3 x 21.1 31 7/8 3/82CXAB048AC3CUA 48,000 A TXVNB1 25.3 x 16.3 x 21.1 36 7/8 3/82CXAC037AC3CUA 36,000 A TXVNB1 20.8 x 19.8 x 21.1 27 11/8 3/82CXAC043AC3CUA 42,000 A TXVNB1 20.8 x 19.8 x 21.1 32 11/8 3/82CXAC049AC3CUA 48,000 A TXVNB1 24.9 x 19.8 x 21.1 34 11/8 3/82CXAC060AC3CUA 60,000 A TXVNB1 29.1 x 19.8 x 21.1 40 11/8 3/82CXAD050AC3CUA 48,000 A TXVNB1 25.1 x 23.3 x 21.1 37 11/8 3/82CXAD061AC3CUA 60,000 A TXVNB1 28.6 x 23.3 x 21.1 42 11/8 3/8

Table FUR-21-C — Cooling Only Uncased Coils (Upflow/ Downflow) R-410A RefrigerantNom. Cap. Overall Shipping Line Size

Model Cooling Coil Refrigerant Dim. (in.) Weight OD ODNumber (Btuh) Type Control H x W x D (Ibs.) Gas Liq.

4CXAA018AC3CUA 18,000 A TXVNB1 15.9 x 13.3 x 21.1 17 5/8 1/44CXAA024AC3CUA 24,000 A TXVNB1 17.6 x 13.3 x 21.1 20 3/4 5/16

4CXAB025AC3CUA 24,000 A TXVNB1 15.9 x 16.3 x 21.1 21 3/4 5/16

4CXAB031AC3CUA 30,000 A TXVNB1 15.9 x 16.3 x 21.1 26 3/4 5/16

4CXAB036AC3CUA 36,000 A TXVNB1 21.2 x 16.3 x 21.1 26 7/8 3/84CXAB042AC3CUA 42,000 A TXVNB1 21.2 x 16.3 x 21.1 31 7/8 3/84CXAB048AC3CUA 48,000 A TXVNB1 25.3 x 16.3 x 21.1 36 7/8 3/84CXAC037AC3CUA 36,000 A TXVNB1 20.8 x 19.8 x 21.1 27 11/8 3/84CXAC043AC3CUA 42,000 A TXVNB1 20.8 x 19.8 x 21.1 32 11/8 3/84CXAC049AC3CUA 48,000 A TXVNB1 24.9 x 19.8 x 21.1 34 11/8 3/84CXAC060AC3CUA 60,000 A TXVNB1 29.1 x 19.8 x 21.1 40 11/8 3/84CXAD050AC3CUA 48,000 A TXVNB1 25.1 x 23.3 x 21.1 37 11/8 3/84CXAD061AC3CUA 60,000 A TXVNB1 28.6 x 23.3 x 21.1 42 11/8 3/8

1 Start Kits may be required on outdoor unit.

Split System - Cased/UncasedCooling Only Coils

2/4CXC Coil Features:• Cased and uncased

upflow /downflow coolingonly coils

• Brazed fittings (left side)• Drain fitting (left side)• Non-Bleed TXV with

mechanical fittings.• Copper tube with

Aluminum fins• Painted coil case• Suction pressure service

port• 100% foil lined insulation• Split inner and outer doors

for easy coil cleaning• 5 Year limited parts

warranty

Comfort TM coil

2/4CXA Coil Features:• Uncased upflow /downflow

cooling only coils• Brazed fittings (left side)• Drain fitting (left side)• Non-Bleed TXV with

mechanical fittings.• Copper tube with Aluminum

fins• Suction pressure service

port• Split inner for easy coil

cleaning• 5 Year limited parts

warranty

Page 96: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

FUR-22Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

High EfficiencySplit System – Cased/UncasedHeat Pump and Cooling Coils

Table FUR-22-A — Brazed, Cased High Efficiency Heat Pump/Cooling Coils-(Upflow, Downflow orHorizontal Left Only) R-22 Refrigerant

Nom. Cap. Outlet Overall Shipping Line SizeModel Cooling Coil Refrigerant Dim. (in.) Dim. (in.) Weight OD ODNumber (Btuh) Type Control W/H x D H x W x D (Ibs.) Gas Liq.

TXC031S3HPC 30,000 A TXVNB1 155/8 x 193/8 22.5 x 17.5 x 21.5 54 3/4 5/16

TXC036S3HPD 36,000 A TXVNB1 155/8 x 193/8 26.9 x 17.5 x 21.5 67 7/8 3/8TXC037S3HPD 36,000 A TXVNB1 191/8 x 193/8 26.9 x 21 x 21.5 70 7/8 3/8TXC054S3HPC 54,000 A TXVNB1 191/8 x 193/8 30.0 x 21 x 21.5 73 11/8 3/8TXC065S3HPC 60,000 A TXVNB1 225/8 x 1911/16 33.0* x 24.5 x 21.5 90 11/8 3/8

Table FUR-22-B — Brazed, Cased Dual Circuit Cooling Only Coils-(Upflow, Downflow or Horizontal Left Only)Nom. Cap. Outlet Overall Shipping Line Size

Model Cooling Coil Refrigerant Dim. (in.) Dim. (in.) Weight OD ODNumber (Btuh) Type Control W/H x D H x W x D (Ibs.) Gas Liq.

TXC039E300C2 36,000 A TXVNB1 155/8 x 195/16 301/16 x 171/2 x 211/2 69 3/4 5/16

TXC059E300C2 59,000 A TXVNB1 191/8 x 195/16 301/16 x 21 x 211/2 73 7/8 3/8TXC062E300C2 64,000 A TXVNB1 225/8 x 195/16 301/16 x 241/2 x 211/2 79 7/8 3/8

1 Start Kits may be required on outdoor unit.2 Only used with Variable Speed Gas Furnace to achieve 2-stage heat/cool.*Overall height. Actual height of case is 30".

Table FUR-22-C — Comfort™ Coils Brazed Coils* (Upflow/Downflow/Horizontal Left Only)R-410A Refrigerant

Nom. Cap. Outlet Uncrated Shipping Line SizeModel Cooling Coil Refrigerant Dim. (in.) Dim. (in.) Weight OD ODNumber (Btuh) Type Control Cased W/H x D H x W x D (Ibs.) Gas Liq.

RXC025S3HPD 24,000 A TXVNB1 Full 155/8 x 195/16 175/8 x 171/2 x 211/2 42 5/8 5/16

RXC031S3HPC 30,000 A TXVNB1 Full 155/8 x 195/16 225/8 x 171/2 x 211/2 54 3/4 5/16

RXC036S3HPD 36,000 A TXVNB1 Full 155/8 x 195/16 267/8 x 171/2 x 211/2 67 3/4 3/8RXC037S3HPD 36,000 A TXVNB1 Full 191/8 x 195/16 267/8 x 21 x 211/2 70 3/4 3/8RXC054S3HPC 54,000 A TXVNB1 Full 191/8 x 195/16 301/16 x 21 x 211/2 73 7/8 3/8RXC061S3HPC 60,000 A TXVNB1 Full 2211/16 x 195/16 301/16 x 241/2 x 211/2 77 7/8 3/8RXC065S3HPC 60,000 A TXVNB1 Partial 225/8 x 195/16 2337/8 x 241/2 x 211/2 94 7/8 3/8

Table FUR-22-D — Brazed Uncased Coils* (Upflow/Downflow) R-410A RefrigerantNom. Cap. Uncrated Line Size

Model Cooling Coil Refrigerant Dim. (in.) Shipping OD ODNumber (Btuh) Type Control Cased H x W x D Weight (Ibs.) Gas Liq.

RXA060S3HPC 60,000 A TXVNB1 None 28 x 199/16 x 199/16 46 3/4 3/8RXA061S3HPC 60,000 A TXVNB1 None 277/16 x 234/16 x 199/16 47 3/4 3/8

1 Start Kits may be required on outdoor unit.2 Overall height. Actual height of case is 30". Downflow application of RXC065 requires field fabrication of case extension shown in

the Installer's Guide.Note: RXC, RXA and RXH series coils include a reducing coupling to accept the smaller interconnecting suction line tubing

recommended with R-410A systems

Table FUR-22-E — Brazed, Cased Dual Circuit Cooling Only Coil2323232323

Nom. Cap. Outlet Overall Shipping Line SizeModel Cooling Coil Refrigerant Dim. (in.) Dim. (in.) Weight OD ODNumber (Btuh) Type Control W/H x D H x W x D (Ibs.) Gas Liq.

TXE120B500D 120,000 Flat TXV-B 183/4 x 573/4 26 x 64 x 25 235 11/8 3/81 Start Kits may be required on outdoor unit.2 Coils are 3/8" cu/al plate fin.3 Two circuit cooling coil.

TXC Comfort™Coil Features:• Split inner and outer doors

for easy coil cleaning• Double sloped non

corrosive drain pans-UL Rated 400°F

• Suction pressure serviceport

• 100% foil lined insulation• Easy case attachment to

furnace• 3 way application• Painted cabinet matches

furnace• 5 Year limited parts

warranty on all coils• Copper tube and

Aluminum fin

RXC ComfortTM CoilFeatures• Refrigerant R-410A only• Split inner and outer

doors for easy coilcleaning

• Double sloped non-corrosive drain pans(UL Rated 400oF)

• Suction pressureservice port

• 100% foil lined insulation• Easy case attachment

to furnace• Painted cabinet matches

furnace• 3 way application• 5-year limited parts

warranty

RXA ComfortTM CoilFeatures• Double sloped non-

corrosive drain pan(UL Rated 400oF)

• Suction pressureservice port

• Easy access servicepanels

• 5-year limited partswarranty

Page 97: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

FUR-23 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

PHASED OUT

PHASED OUT

Split System – CasedHeat Pump and Cooling Coils

1 – 5 TonCased Coils• Split inner and outer

doors for easy coilcleaning

• Double sloped noncorrosive drain pans-UL Rated 400° F

• Suction pressure serviceport

• 100% foil lined insulation• External FCCV location• Easy case attachment to

furnace• 3 way application• Painted cabinet matches

furnace• 5 year limited parts

warranty on all coils• FCCV equipped coils

compatible with R-22 orR-410A refrigerant

• Upflow, downflow orhorizontal left only(TXC-E/TXC-S)

PHASED OUT

RXH ComfortTM CoilFeatures• Sloped non-corrosive

drain pan (UL Rated400oF)

• Bi-directional airflow• Galvanized case -

unpainted• Suction pressure port• 5-year limited parts

warranty

PHASED OUT PHASED OUT PHASED OUT PHASED OUT

PHASED OUT

Table FUR-23-A — Brazed, Cased Heat Pump/Cooling Coils-(Upflow, Downflow or Horizontal Left Only*)Nom. Cap. Outlet Overall Shipping Line Size

Model Cooling Coil Refrigerant Dim. (in.) Dim. (in.) Weight OD ODNumber (Btuh) Type Control W/H x D H x W x D (Ibs.) Gas Liq.

TXC018C4HPC 18,000 A .049 125/8 x 193/8 175/8 x 141/2 x 211/2 32 5/8 1/4TXC024C4HPC 24,000 A .049 125/8 x 193/8 175/8 x 141/2 x 211/2 34 3/4 5/16

TXC025C4HPC 24,000 A .057 155/8 x 193/8 175/8 x 171/2 x 211/2 39 3/4 5/16

TXC030C4HPC 30,000 A .067 125/8 x 193/8 225/8 x 141/2 x 211/2 37 3/4 5/16

TXC031C4HPC 31,000 A .067 155/8 x 193/8 175/8 x 171/2 x 211/2 43 3/4 5/16

TXC035C4HPC 35,000 A .071 125/8 x 193/8 225/8 x 141/2 x 211/2 37 7/8 3/8TXC036C4HPC 36,000 A .071 155/8 x 193/8 225/8 x 171/2 x 211/2 51 7/8 3/8TXC037C4HPC 37,000 A .071 191/8 x 193/8 225/8 x 21 x 211/2 54 7/8 3/8TXC042C4HPC 42,000 A .080 155/8 x 193/8 225/8 x 171/2 x 211/2 56 7/8 3/8TXC043C4HPC 43,000 A .080 191/8 x 193/8 225/8 x 21 x 211/2 57 11/8 3/8TXC048C4HPD 48,000 A .083 155/8 x 193/8 267/8 x 171/2 x 211/2 68 11/8 3/8TXC049C4HPD 48,000 A .083 191/8 x 193/8 267/8 x 21 x 211/2 69 11/8 3/8TXC050C4HPD 48,000 A .083 225/8 x 195/16 267/8 x 241/2 x 211/2 69 11/8 3/8TXC060C5HPC 60,000 A TXV-B 191/8 x 193/8 301/16 x 21 x 211/2 69 11/8 3/8TXC061C5HPC 61,000 A TXV-B 225/8 x 195/16 301/16 x 241/2 x 211/2 71 11/8 3/8

Table FUR-23-B —Brazed, Cased High Efficiency Heat Pump/Cooling Coils-(Upflow, Downflow orHorizontal Left Only*)

Nom. Cap. Outlet Overall Shipping Line SizeModel Cooling Coil Refrigerant Dim. (in.) Dim. (in.) Weight OD ODNumber (Btuh) Type Control W/H x D H x W x D (Ibs.) Gas Liq.

TXC031E5HPC 30,000 A TXV-B 155/8 x 193/8 225/8 x 171/2 x 211/2 54 3/4 5/16

TXC036E5HPD 36,000 A TXV-B 155/8 x 193/8 267/8 x 171/2 x 211/2 67 7/8 3/8TXC037E5HPD 37,000 A TXV-B 191/8 x 193/8 267/8 x 21 x 211/2 70 7/8 3/8TXC054E5HPC 54,000 A TXV-B 191/8 x 193/8 301/16 x 21 x 211/2 73 11/8 3/8

Table FUR-23-C — Brazed,Cased Heat Pump/Cooling Coils-(Upflow, Downflow or Horizontal Left or Right)Nom. Cap. Outlet Overall Shipping Line Size

Model Cooling Coil Refrigerant Dim. (in.) Dim. (in.) Weight OD ODNumber (Btuh) Type Control W/H x D H x W x D (Ibs.) Gas Liq.

TXC024D4HPC 24,000 A .057 125/8 x 193/8 301/16 x 141/2 x 211/2 42 3/4 5/16

TXC025D4HPC 24,000 A .057 155/8 x 193/8 301/16 x 171/2 x 211/2 48 3/4 5/16

TXC030D4HPC 30,000 A .067 125/8 x 193/8 301/16 x 141/2 x 211/2 46 3/4 5/16

TXC031D4HPC 30,000 A .067 155/8 x 193/8 301/16 x 171/2 x 211/2 52 3/4 5/16

TXC035D4HPC 35,000 A .071 125/8 x 193/8 301/16 x 141/2 x 211/2 46 7/8 3/8TXC036D4HPC 36,000 A .071 155/8 x 193/8 301/16 x 171/2 x 211/2 60 7/8 3/8

* TXC series coils include a reducing coupling to accept the smaller interconnecting suction line tubing recommended with R-410Asystems.

Table FUR-23-D — Horizontal Only Cased Coil* R-410A RefrigerantNom. Cap. Uncrated Line Size

Model Cooling Coil Refrigerant Dim. (in.) Shipping OD ODNumber (Btuh) Type Control Cased H x W x D Weight (Ibs.) Gas Liq.

RXH063S3HPB 63,500 Flat TXVNB1 Full 283/4 x 101/4 x 371/2 79 3/4 3/8

Table FUR-23-E — Cased Horizontal OnlyNom. Cap. Duct Con. Uncrated Line Size

Model Cooling Coil Refrigerant Dim. (in.) Dim. (in.) Shipping OD ODNumber (Btuh) Type Control H x W H x W x D Weight (Ibs.) Gas Liq.

TXH025A4HPA 27,000 Flat .057 21 x 24 22 x 10 x 28 40 3/4 5/16

TXH033A4HPA 34,000 Flat .057 21 x 24 22 x 10 x 28 46 3/4 3/8TXH041A4HPA 44,000 Flat .067 21 x 331/4 22 x 10 x 37 56 7/8 3/8TXH054A4HPA 58,000 Flat .083 21 x 331/4 22 x 10 x 37 64 7/8 3/8TXH063P3HPB 61,000 Flat TXVNB1 27 x 331/4 28 x 10 x 37 79 7/8 3/8

1 Start Kits may be required on outdoor unit.* RXH series coils include a reducing coupling to accept the smaller interconnecting suction line tubing recommended with R-410A

systems.

Page 98: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

FUR-24Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

PHASED OUT1 – 5 TonUncased Coils• 5-year limited parts

warranty• FCCV equipped coils

compatible with R-22 orR-410A refrigerant

Split System – Cased/UncasedHeat Pump and Cooling Coils

Table FUR-24-A — Brazed, Uncased Heat Pump/Cooling Coils (Upflow/Downflow)Nom. Cap. Uncrated Line Size

Model Cooling Coil Refrigerant Dim. (in.) Shipping OD ODNumber (Btuh) Type Control Cased H x W x D Weight (Ibs.) Gas Liq.

TXA018C4HPC 18,000 A .049 No 155/16 x 131/16 x 199/16 15 5/8 1/4TXA024C4HPC 24,000 A .049 No 165/8 x 131/16 x 199/16 18 3/4 5/16

TXA025C4HPC 24,000 A .057 No 151/8 x 161/16 x 199/16 20 3/4 5/16

TXA030C4HPC 30,000 A .067 No 193/4 x 131/16 x 199/16 23 3/4 5/16

TXA031C4HPC 30,000 A .067 No 16 x 161/16 x 199/16 24 3/4 5/16

TXA035C4HPC 35,000 A .071 No 193/4 X 131/16 X 199/16 23 7/8 5/16

TXA036C4HPC 36,000 A .071 No 191/8 x 161/16 x 199/16 29 7/8 3/8TXA037C4HPC 36,000 A .071 No 189/16 x 199/16 x 199/16 29 7/8 3/8TXA042C4HPC 42,000 A .080 No 211/4 x 161/16 x 199/16 34 7/8 3/8TXA043C4HPC 42,000 A .080 No 2011/16 x 199/16 x 199/16 32 7/8 3/8TXA048C4HPC 48,000 A .083 No 255/16 x 161/16 x 199/16 39 11/8 3/8TXA049C4HPC 48,000 A .083 No 247/8 x 199/16 x 199/16 37 11/8 3/8TXA050C4HPC 48,000 A .083 No 243/8 x 231/16 x 199/16 38 11/8 3/8TXA060C5HPC 60,000 A TXV - B No 28 x 199/16 x 199/16 43 11/8 3/8TXA061C5HPC 60,000 A TXV - B No 277/16 x 231/16 x 199/16 44 11/8 3/8

PHASED OUT

PHASED OUT

Table FUR-24-B — Brazed Cased (Upflow Only)Nom. Cap. Outlet Uncrated Line Size

Model Cooling Coil Refrigerant Dim. (in.) Dim. (in.) Shipping OD ODNumber (Btuh) Type Control H x W H x W x D Weight (Ibs.) Gas Liq.

CCBA18A4ACD 18,000 A FIXED 125/8 x 193/8 175/8 x 141/2 x 211/2 30 5/8 5/16

CCBA24A4ACD 24,000 A FIXED 125/8 x 193/8 175/8 x 141/2 x 211/2 32 3/4 5/16

CCBA30A4ACD 30,000 A FIXED 125/8 x 193/8 175/8 x 141/2 x 211/2 32 3/4 5/16

CCBA36A4ACD 36,000 A FIXED 125/8 x 193/8 225/8 x 141/2 x 211/2 35 3/4 5/16

CCBB30A4ACD 30,000 A FIXED 155/8 x 193/8 175/8 x 171/2 x 211/2 41 3/4 5/16

CCBB36A4ACD 36,000 A FIXED 155/8 x 193/8 175/8 x 171/2 x 211/2 41 3/4 5/16

CCBB42A4ACD 42,000 A FIXED 155/8 x 193/8 225/8 x 171/2 x 211/2 49 3/4 3/8CCBB48A4ACD 48,000 A FIXED 155/8 x 193/8 225/8 x 171/2 x 211/2 54 3/4 3/8CCBC48A4ACD 48,000 A FIXED 191/8 x 193/8 225/8 x 21 x 211/2 55 3/4 3/8CCBC60A4ACE 60,000 A FIXED 191/8 x 193/8 267/8 x 21 x 211/2 67 7/8 3/8CCBD60A5ACD 60,000 A TXV-B 225/8 x 195/16 301/16 x 241/2 x 211/2 69 7/8 3/8

Table FUR-24-C — Brazed Uncased (Upflow Only)Nom. Cap. Uncrated Line Size

Model Cooling Coil Refrigerant Dim. (in.) Shipping OD ODNumber (Btuh) Type Control Cased H x W x D Weight (Ibs.) Gas Liq.

CUBA18A4ACD 18,000 A FIXED No 111/2 x 131/16 x 199/16 15 5/8 5/16

CUBA24A4ACD 24,000 A FIXED No 145/8 x 131/16 x 199/16 18 3/4 5/16

CUBA30A4ACD 30,000 A FIXED No 145/8 x 131/16 x 199/16 18 3/4 5/16

CUBA36A4ACD 36,000 A FIXED No 193/4 x 131/16 x 199/16 18 3/4 5/16

CUBB24A4ACD 24,000 A FIXED No 153/16 x 161/16 x 199/16 23 3/4 5/16

CUBB30A4ACD 30,000 A FIXED No 16 x 161/16 x 199/16 24 3/4 5/16

CUBB36A4ACD 36,000 A FIXED No 16 x 161/16 x 199/16 24 3/4 5/16

CUBB42A4ACD 42,000 A FIXED No 191/8 x 161/16 x 199/16 24 3/4 3/8CUBB48A4ACD 48,000 A FIXED No 211/4 x 161/16 x 199/16 29 3/4 3/8CUBC36A4ACD 36,000 A FIXED No 165/16 x 199/16 x 199/16 27 3/4 5/16

CUBC42A4ACD 42,000 A FIXED No 189/16 x 199/16 x 199/16 34 3/4 3/8CUBC48A4ACD 48,000 A FIXED No 2011/16 x 199/16 x 199/16 32 3/4 3/8CUBC60A4ACD 60,000 A FIXED No 247/8 x 199/16 x 199/16 31 7/8 3/8CUBD48A4ACD 48,000 A FIXED No 205/8 x 231/16 x 199/16 37 3/4 3/8CUBD60A5ACD 60,000 A TXV-B No 277/16 x 231/16 x 199/16 44 3/4 3/8

11/2 – 5 TonCased & Uncased• Cased and uncased upflow

cooling only coils• Brazed fittings (left side)• Drain fitting (left side)• Fixed orifice flow control

(except CCBD60A5ACD,CUBD60A5ACD-TXV-B)

• Shipped vertical upflowonly

• Painted coil case• Suction pressure service

port• 100% foil lined insulation• Split inner and outer doors

for easy coil cleaning• 5 year limited parts

warranty

Page 99: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

FUR-25 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Table FUR-25-A — Coil EnclosuresModel Coils Cooling or Used With Furnaces Outlet Dimensions (in) Dimensions (in.) ShippingNumber Heat Pump Flush on Both Sides W/H x D H x W x D Weight (Ibs.)

BAYCLE1400C TXA018C4 141/2" Wide Furnaces 125/8 x 195/16 221/2 x 141/2 x 211/2 12TXA024C4TXA030C4

BAYCLE1700C TXA025C4 171/2" Wide Furnaces 155/8 x 195/16 221/2 x 171/2 x 211/2 14TXA031C4TXA035C4TXA036C4TXA042C4TXA048C4

BAYCLE2100C TXA037C4 21" Wide Furnaces 191/8 x 195/16 30 x 21 x 211/2 18TXA043C4TXA049C4TXA060C5RXA060S3

BAYCLE2400C TXA061C5 241/2" Wide Furnaces 225/8 x 195/16 30 x 241/2 x 211/2 22RXA061S3

Table FUR-25-B — 13 SEER Coil EnclosuresModel Used With Furnaces Dimensions (in.) ShippingNumber Coils Cooling or Heat Pump Flush on Both Sides H x W x D Weight (Ibs.)

BAYCLE14A1422A 2/4CXAA018AC3CUA TXA018C4 141/2" Wide Furnace 221/2 x 141/2 x 211/2 122/4CXAA024AC3CUA TXA024C4

TXA030C4BAYCLE17A1722A 2/4CXAB025AC3CUA TXA025C4 171/2" Wide Furnace 225/8 x 171/2 x 211/2 14

2/4CXAB031AC3CUA TXA031C42/4CXAB036AC3CUA TXA035C42/4CXAB042AC3CUA TXA036C42/4CXAB048AC3CUA TXA042C4

TXA048C4BAYCLE21A2130A 2/4CXAC037AC3CUA TXA037C4 21" Wide Furnace 30 x 21 x 211/2 18

2/4CXAC043AC3CUA TXA043C42/4CXAC049AC3CUA TXA049C42/4CXAC060AC3CUA TXA060C5

RXA060S3BAYCLE24A2430A 2/4CXAD050AC3CUA TXA061C5 241/2" Wide Furnace 30 x 241/2 x 211/2 22

2/4CXAD061AC3CUA RXA061S3

Table FUR-25-C — ComfortTM Coil Door KitsModel Number Case Height Used WithBAYCCKT1750A 17.5 TXC018,024,025,031-C-A,BBAYCCKT2250A 22.5 TXC030,035,036,037,042,043-C-A,B

TXC031-E/S-A,BBAYCCKT3000A 30.0 TXC048,049,050,060,061-C-A,B

TXC036,037,054,065-E/S-A,B

Split System – UncasedCoil Enclosures

Page 100: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

FUR-26Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

XL 90, XV 90 & CoilsFurnace Cabinet Matching Matching Furnace Cabinet Matching MatchingModel Width Cased Coils Uncased Coils Model Width Cased Coils Uncased CoilsTUX060R936W 17.5" 2CXCB025A TXC025C 2CXAB025A TXA025C TDX060R936W 17.5" 2CXCB025A TXC025C 2CXAB025A TXA025CTUX080R942W 17.5" 2CXCB031A TXC031C 2CXAB031A TXA031C TDX080R942W 17.5" 2CXCB031A TXC031C 2CXAB031A TXA031C

2CXCB036A TXC036C 2CXAB036A TXA036C 2CXCB036A TXC036C 2CXAB036A TXA036C2CXCB042A TXC042C 2CXAB042A TXA042C 2CXCB042A TXC042C 2CXAB042A TXA042C2CXCB048A TXC048C 2CXAB048A TXA048C 2CXCB048A TXC048C 2CXAB048A TXA048C2TXCB025A TXC025D 2TXCB025A TXC025D2TXCB031A TXC031D 2TXCB031A TXC031D2TXCB036A TXC036D 2TXCB036A TXC036D2TXCB042A TXC031E 2TXCB042A TXC031E2TXCB048A TXC036E 2TXCB048A TXC036E4CXCB025A TXC031S 4CXCB025A TXC031S4CXCB031A TXC036S 4CXCB031A TXC036S4CXCB036A RXC025S 4CXCB036A RXC025S4CXCB042A RXC031S 4CXCB042A RXC031S4CXCB048A RXC036S 4CXCB048A RXC036S4TXCB025A CUBB24A 4TXCB025A4TXCB031A CCBB30A CUBB30A 4TXCB031A4TXCB036A CCBB36A CUBB36A 4TXCB036A4TXCB042A CCBA42A CUBB42A 4TXCB042A4TXCB048A CCBA48A CUBB48A 4TXCB048A

TUX100R948W 21" 2CXCC037A TXC037C 2CXAC037A TXA037C TDX100R948W 21" 2CXCC037A TXC037C 2CXAC037A TXA037C2CXCC043A TXC043C 2CXAC043A TXA043C 2CXCC043A TXC043C 2CXAC043A TXA043C2CXCC049A TXC049C 2CXAC049A TXA049C 2CXCC049A TXC049C 2CXAC049A TXA049C2CXCC060A TXC060C 2CXAC060A TXA060C 2CXCC060A TXC060C 2CXAC060A TXA060C2TXCC037A TXC037E 2TXCC037A TXC037E2TXCC043A TXC054E 2TXCC043A TXC054E2TXCC049A TXC037S 2TXCC049A TXC037S2TXCC054A TXC054S 2TXCC054A TXC054S2TXCC060A RXC037S 2TXCC060A RXC037S4CXCC037A RXC054S 4CXCC037A RXC054S4CXCC043A CUBC36A 4CXCC043A4CXCC049A CUBC42 A 4CXCC049A4CXCC060A CCBC48A CUBC48A 4CXCC060A4TXCC037A CCBC60A CUBC60A 4TXCC037A4TXCC043A 4TXCC043A4TXCC049A 4TXCC049A4TXCC054A 4TXCC054A4TXCC060A 4TXCC060A

TUX120R960W 24.5" 2CXCD050A TXC050C 2CXAD050A TXA060C TDX120R960W 24.5" 2CXCD050A TXC050C 2CXAD050A TXA060C2CXCD061A TXC061C 2CXAD061A TXA061C 2CXCD061A TXC061C 2CXAD061A TXA061C2TXCD050A TXC065S1 2TXCD050A TXC065S1

2TXCD061A RXC061S 2TXCD061A RXC061S2TXCD065A RXC065S1 2TXCD065A RXC065S1

4CXCD050A CUBD48A 4CXCD050A4CXCD061A CCBD60A CUBD60A 4CXCD061A4TXCD050A 4TXCD050A4TXCD061A 4TXCD061A4TXCD065A 4TXCD065A

TUY060R9V3W 17.5" TXC031E TDY060R9V3W 17.5" TXC031ETUY080R9V3W 17.5" TXC036E TDY080R9V3W 17.5" TXC036E

TXC031S TXC031STXC036S TXC036SRXC025S RXC025SRXC031S RXC031SRXC036S RXC036S

TUY100R9V4W 21" TXC037E TDY100R9V4W 21" TXC037ETXC054E TXC054ETXC037S TXC037STXC054S TXC054SRXC037S RXC037SRXC054S RXC054S

TUY120R9V5W 24.5" TXC065S1 TDY120R9V5W 24.5" TXC065S1RXC061S RXC061SRXC065S1 RXC065S1

NOTE: For reference only on Flush Fit Applications1 Coil apex extends above case, actual height of case is 30" (Downflow application of coil is not recommended).

Furnace/CoilsMatrix

Page 101: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

FUR-27 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Furnace/CoilsMatrix

XT 90 & CoilsMatching Matching Matching Matching

Furnace Cabinet Cased Uncased Furnace Cabinet Cased UncasedModel Width Coils Coils Model Width Coils CoilsTUX1B040A9H21A 17.5" 2CXCB025A 2CXAB025A TDX1B040A9H31A 17.5" 2CXCB025A 2CXAB025ATUX1B060A9H31A 17.5" 2CXCB031A 2CXAB031A TDX1B060A9H31A 17.5" 2CXCB031A 2CXAB031ATUX1B080A9H31A 17.5" 2CXCB036A 2CXAB036A TDX1B080A9H31A 17.5" 2CXCB036A 2CXAB036A

2CXCB042A 2CXAB042A 2CXCB042A 2CXAB042A2CXCB048A 2CXAB048A 2CXCB048A 2CXAB048A2TXCB025A 2TXCB025A2TXCB031A 2TXCB031A2TXCB036A 2TXCB036A2TXCB042A 2TXCB042A2TXCB048A 2TXCB048A4CXCB025A 4CXCB025A4CXCB031A 4CXCB031A4CXCB036A 4CXCB036A4CXCB042A 4CXCB042A4CXCB048A 4CXCB048A4TXCB025A 4TXCB025A4TXCB031A 4TXCB031A4TXCB036A 4TXCB036A4TXCB042A 4TXCB042A4TXCB048A 4TXCB048A

TUX1C100A9H41A 21" 2CXCC037A 2CXAC037A TDX1C100A9H41A 21" 2CXCC037A 2CXAC037A2CXCC043A 2CXAC043A 2CXCC043A 2CXAC043A2CXCC049A 2CXAC049A 2CXCC049A 2CXAC049A2CXCC060A 2CXAC060A 2CXCC060A 2CXAC060A2TXCC037A 2TXCC037A2TXCC043A 2TXCC043A2TXCC049A 2TXCC049A2TXCC054A 2TXCC054A2TXCC060A 2TXCC060A4CXCC037A 4CXCC037A4CXCC043A 4CXCC043A4CXCC049A 4CXCC049A4CXCC060A 4CXCC060A4TXCC037A 4TXCC037A4TXCC043A 4TXCC043A4TXCC049A 4TXCC049A4TXCC054A 4TXCC054A4TXCC060A 4TXCC060A

TUX1D120A9H51A 24.5" 2CXCD050A 2CXAD050A TDX1D120A9H51A 24.5" 2CXCD050A 2CXAD050A2CXCD061A 2CXAD061A 2CXCD061A 2CXAD061A2TXCD050A 2TXCD050A2TXCD061A 2TXCD061A2TXCD065A 2TXCD065A4CXCD050A 4CXCD050A4CXCD061A 4CXCD061A4TXCD050A 4TXCD050A4TXCD061A 4TXCD061A4TXCD065A 4TXCD065A

NOTE: For reference only on Flush Fit Applications

Page 102: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

FUR-28Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

XR 90 & CoilsFurnace Cabinet Matching Matching Furnace Cabinet Matching MatchingModel Width Cased Coils Uncased Coils Model Width Cased Coils Uncased CoilsTUX040C924D 17.5" 2CXCB025A TXC025C 2CXAB025A TXA025C TDX040C924D 17.5" 2CXCB025A TXC025C 2CXAB025A TXA025CTUX060C936D 17.5" 2CXCB031A TXC031C 2CXAB031A TXA031C TDX060C936D 17.5" 2CXCB031A TXC031C 2CXAB031A TXA031CTUX080C942D 17.5" 2CXCB036A TXC036C 2CXAB036A TXA036C TDX080C942D 17.5" 2CXCB036A TXC036C 2CXAB036A TXA036CTUX1B040A9241A 17.5" 2CXCB042A TXC042C 2CXAB042A TXA042C TDX1B040A9241A 17.5" 2CXCB042A TXC042C 2CXAB042A TXA042CTUX1B060A9361A 17.5" 2CXCB048A TXC048C 2CXAB048A TXA048C TDX1B060A9361A 17.5" 2CXCB048A TXC048C 2CXAB048A TXA048CTUX1B080A9421A 17.5" 2TXCB025A TXC025D TDX1B080A9421A 17.5" 2TXCB025A TXC025D

2TXCB031A TXC031D 2TXCB031A TXC031D2TXCB036A TXC036D 2TXCB036A TXC036D2TXCB042A TXC031E 2TXCB042A TXC031E2TXCB048A TXC036E 2TXCB048A TXC036E4CXCB025A TXC031S 4CXCB025A TXC031S4CXCB031A TXC036S 4CXCB031A TXC036S4CXCB036A RXC025S 4CXCB036A RXC025S4CXCB042A RXC031S 4CXCB042A RXC031S4CXCB048A RXC036S 4CXCB048A RXC036S4TXCB025A CUBB24A 4TXCB025A4TXCB031A CCBB30A CUBB30A 4TXCB031A4TXCB036A CCBB36A CUBB36A 4TXCB036A4TXCB042A CCBA42A CUBB42A 4TXCB042A4TXCB048A CCBA48A CUBB48A 4TXCB048A

TUX080C960D 21" 2CXCC037A TXC037C 2CXAC037A TXA037C TDX100C948D 21" 2CXCC037A TXC037C 2CXAC037A TXA037CTUX100C948D 21" 2CXCC043A TXC043C 2CXAC043A TXA043C TDX1C100A9481A 21" 2CXCC043A TXC043C 2CXAC043A TXA043CTUX1C080A9601A 21" 2CXCC049A TXC049C 2CXAC049A TXA049C 2CXCC049A TXC049C 2CXAC049A TXA049CTUX1C100A9481A 21" 2CXCC060A TXC060C 2CXAC060A TXA060C 2CXCC060A TXC060C 2CXAC060A TXA060C

2TXCC037A TXC037E 2TXCC037A TXC037E2TXCC043A TXC054E 2TXCC043A TXC054E2TXCC049A TXC037S 2TXCC049A TXC037S2TXCC054A TXC054S 2TXCC054A TXC054S2TXCC060A RXC037S 2TXCC060A RXC037S2TXCC037A RXC054S 2TXCC037A RXC054S4CXCC043A CUBC36A 4CXCC043A4CXCC049A CUBC42 A 4CXCC049A4CXCC060A CCBC48A CUBC48A 4CXCC060A4TXCC037A CCBC60A CUBC60A 4TXCC037A4TXCC043A 4TXCC043A4TXCC049A 4TXCC049A4TXCC054A 4TXCC054A4TXCC060A 4TXCC060A

TUX100C960D 24.5" 2CXCD050A TXC050C 2CXAD050A TXA060C TDX120C960D 24.5" 2CXCD050A TXC050C 2CXAD050A TXA060CTUX120C960D 24.5" 2CXCD061A TXC061C 2CXAD061A TXA061C TDX1D120A9601A 24.5" 2CXCD061A TXC061C 2CXAD061A TXA061CTUX1D100A9601A 2TXCD050A TXC065S1 2TXCD050A TXC065S1TUX1D120A9601A 2TXCD061A RXC061S 2TXCD061A RXC061S

2TXCD065A RXC065S1 2TXCD065A RXC065S14CXCD050A CUBD48A 4CXCD050A4CXCD061A CCBD60A CUBD60A 4CXCD061A4TXCD050A 4TXCD050A4TXCD061A 4TXCD061A4TXCD065A 4TXCD065A

NOTE: For reference only on Flush Fit Applications1 Coil apex extends above case, actual height of case is 30" (Downflow application of coil is not recommended).

Furnace/CoilsMatrix

Page 103: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

FUR-29 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Furnace/CoilsMatrix

XB 90 & CoilsFurnace Cabinet Matching Matching Furnace Cabinet Matching MatchingModel Width Cased Coils Uncased Coils Model Width Cased Coils Uncased CoilsTUC040C924B 17.5" 2CXCB025A TXC025C 2CXAB025A TXA025C TDC040C924B 17.5" 2CXCB025A TXC025C TXA025CTUC060C936B 17.5" 2CXCB031A TXC031C 2CXAB031A TXA031C TDC060C936B 17.5" 2CXCB031A TXC031C TXA031CTUC080C942B 17.5" 2CXCB036A TXC036C 2CXAB036A TXA036C TDC080C942B 17.5" 2CXCB036A TXC036C TXA036C

2CXCB042A TXC042C 2CXAB042A TXA042C 2CXCB042A TXC042C TXA042C2CXCB048A TXC048C 2CXAB048A TXA048C 2CXCB048A TXC048C TXA048C2TXCB025A TXC025D 2TXCB025A TXC025D2TXCB031A TXC031D 2TXCB031A TXC031D2TXCB036A TXC036D 2TXCB036A TXC036D2TXCB042A TXC031E 2TXCB042A TXC031E2TXCB048A TXC036E 2TXCB048A TXC036E4CXCB025A TXC031S 4CXCB025A TXC031S4CXCB031A TXC036S 4CXCB031A TXC036S4CXCB036A RXC025S 4CXCB036A RXC025S4CXCB042A RXC031S 4CXCB042A RXC031S4CXCB048A RXC036S 4CXCB048A RXC036S4TXCB025A CUBB24A 4TXCB025A4TXCB031A CCBB30A CUBB30A 4TXCB031A4TXCB036A CCBB36A CUBB36A 4TXCB036A4TXCB042A CCBA42A CUBB42A 4TXCB042A4TXCB048A CCBA48A CUBB48A 4TXCB048A

TUC100C948B 21" 2CXCC037A TXC037C 2CXAC037A TXA037C TDC100C948B 21" 2CXCC037A TXC037C TXA037C2CXCC043A TXC043C 2CXAC043A TXA043C 2CXCC043A TXC043C TXA043C2CXCC049A TXC049C 2CXAC049A TXA049C 2CXCC049A TXC049C TXA049C2CXCC060A TXC060C 2CXAC060A TXA060C 2CXCC060A TXC060C TXA060C2TXCC037A TXC037E 2TXCC037A TXC037E2TXCC043A TXC054E 2TXCC043A TXC054E2TXCC049A TXC037S 2TXCC049A TXC037S2TXCC054A TXC054S 2TXCC054A TXC054S2TXCC060A RXC037S 2TXCC060A RXC037S4CXCC037A RXC054S 4CXCC037A RXC054S4CXCC043A CUBC36A 4CXCC043A4CXCC049A CUBC42 A 4CXCC049A4CXCC060A CCBC48A CUBC48A 4CXCC060A4TXCC037A CCBC60A CUBC60A 4TXCC037A4TXCC043A 4TXCC043A4TXCC049A 4TXCC049A4TXCC054A 4TXCC054A4TXCC060A 4TXCC060A

TUC100C960B 24.5" 2CXCD050A TXC050C 2CXAD050A TXA060C TDC120C960B 24.5" 2CXCD050A TXC050C TXA060CTUC120C960B 24.5" 2CXCD061A TXC061C 2CXAD061A TXA061C 2CXCD061A TXC061C TXA061C

2TXCD050A TXC065S1 2TXCD050A TXC065S1

2TXCD061A RXC061S 2TXCD061A RXC061S2TXCD065A RXC065S1 2TXCD065A RXC065S1

4CXCD050A CUBD48A 4CXCD050A4CXCD061A CCBD60A CUBD60A 4CXCD061A4TXCD050A 4TXCD050A4TXCD061A 4TXCD061A4TXCD065A 4TXCD065A

NOTE: For reference only on Flush Fit Applications1 Coil apex extends above case, actual height of case is 30" (Downflow application of coil is not recommended).

Page 104: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

FUR-30Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Furnace/CoilsMatrix

XV 80 & CoilsFurnace Cabinet Matching Matching Furnace Cabinet Matching MatchingModel Width Cased Coils Uncased Coils Model Width Cased Coils Uncased Coils

TUD060R9V3K 17.5" TXC031E TDD060R9V3F 17.5" TXC031ETUD080R9V3K 17.5" TXC036E TDD080R9V3F 17.5" TXC036ETUD100R9V3K TXC031S TXC031S

TXC036S TXC036SRXC025S RXC025SRXC031S RXC031SRXC036S RXC036S

TUD080R9V4K 21" TXC054E TDD100R9V5F 21" TXC037ETUD100R9V5K 21" TXC037E TXC054E

TXC037S TXC037STXC054S TXC054SRXC037S RXC037SRXC054S RXC054S

TUD120R9V5K 24.5" TXC065S1 TDD120R9V5F 24.5" TXC065S1TUD140R9V5K 24.5" RXC061S RXC061S

RXC065S1 RXC065S1

NOTE: For reference only on Flush Fit Applications1 Coil apex extends above case, actual height of case is 30" (Downflow application of coil is not recommended).

Page 105: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

FUR-31 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

XL 80 & CoilsFurnace Cabinet Matching Matching Furnace Cabinet Matching MatchingModel Width Cased Coils Uncased Coils Model Width Cased Coils Uncased CoilsTUD040R924K 14.5" 2CXCA018A TXC018C 2CXAA018A TXA018C TDD040R924F 14.5" 2CXCA018A TXC018C 2CXAA018A TXA018CTUD060R936K 14.5" 2CXCA024A TXC024C 2CXAA024A TXA024C TDD060R936F 14.5" 2CXCA024A TXC024C 2CXAA024A TXA024C

2TXCA018A TXC030C TXA030C 2TXCA018A TXC030C TXA030C2TXCA024A TXC035C TXA035C 2TXCA024A TXC035C TXA035C4CXCA018A TXC024D 4CXCA018A TXC024D4CXCA024A TXC030D 4CXCA024A TXC030D4TXCA018A TXC035D 4TXCA018A TXC035D4TXCA024A CCBA18A CUBA18A 4TXCA024A

CCBA24A CUBA24ACCBA30A CUBA30ACCBA36A CUBA36A

TUD060R937K 17.5" 2CXCB025A TXC025C 2CXAB025A TDD060R937F 17.5" 2CXCB025A TXC025C 2CXAB025A TXA025CTUD080R936K 17.5" 2CXCB031A TXC031C 2CXAB031A TDD080R936F 17.5" 2CXCB031A TXC031C 2CXAB031A TXA031CTUD080R948K 17.5" 2CXCB036A TXC036C 2CXAB036A TDD100R945F 17.5" 2CXCB036A TXC036C 2CXAB036A TXA036CTUD100R936K 17.5" 2CXCB042A TXC042C 2CXAB042A TXA025C 2CXCB042A TXC042C 2CXAB042A TXA042C

2CXCB048A TXC048C 2CXAB048A TXA031C 2CXCB048A TXC048C 2CXAB048A TXA048C2TXCB025A TXC025D TXA036C 2TXCB025A TXC025D2TXCB031A TXC031D TXA042C 2TXCB031A TXC031D2TXCB036A TXC036D TXA048C 2TXCB036A TXC036D2TXCB042A TXC031E 2TXCB042A TXC031E2TXCB048A TXC036E 2TXCB048A TXC036E4CXCB025A TXC031S 4CXCB025A TXC031S4CXCB031A TXC036S 4CXCB031A TXC036S4CXCB036A RXC025S 4CXCB036A RXC025S4CXCB042A RXC031S 4CXCB042A RXC031S4CXCB048A RXC036S 4CXCB048A RXC036S4TXCB025A CUBB24A 4TXCB025A4TXCB031A CCBB30A CUBB30A 4TXCB031A4TXCB036A CCBB36A CUBB36A 4TXCB036A4TXCB042A CCBA42A CUBB42A 4TXCB042A4TXCB048A CCBA48A CUBB48A 4TXCB048A

TUD100R948K 21" 2CXCC037A TXC037C 2CXAC037A TXA037C TDD100R948F 21" 2CXCC037A TXC037C 2CXAC037A TXA037CTUD100R960K 21" 2CXCC043A TXC043C 2CXAC043A TXA043C TDD100R960F 21" 2CXCC043A TXC043C 2CXAC043A TXA043C

2CXCC049A TXC049C 2CXAC049A TXA049C 2CXCC049A TXC049C 2CXAC049A TXA049C2CXCC060A TXC060C 2CXAC060A TXA050C 2CXCC060A TXC060C 2CXAC060A TXA050C2TXCC037A TXC037E 2TXCC037A TXC037E2TXCC043A TXC054E 2TXCC043A TXC054E2TXCC049A TXC037S 2TXCC049A TXC037S2TXCC054A TXC054S 2TXCC054A TXC054S2TXCC060A RXC037S 2TXCC060A RXC037S4CXCC037A RXC054S 4CXCC037A RXC054S4CXCC043A CUBC36A 4CXCC043A4CXCC049A CUBC42A 4CXCC049A4CXCC060A CCBC48A CUBC48A 4CXCC060A4TXCC037A CCBC60A CUBC60A 4TXCC037A4TXCC043A 4TXCC043A4TXCC049A 4TXCC049A4TXCC054A 4TXCC054A4TXCC060A 4TXCC060A

TUD120R960K 24.5" 2CXCD050A TXC050C 2CXAD050A TXA060C TDD120R960F 24.5" 2CXCD050A TXC050C 2CXAD050A TXA060CTUD140R960K 24.5" 2CXCD061A TXC061C 2CXAD061A TXA061C TDD140R960F 24.5" 2CXCD061A TXC061C 2CXAD061A TXA061C

2TXCD050A TXC065S1 2TXCD050A TXC065S1

2TXCD061A RXC061S 2TXCD061A RXC061S2TXCD065A RXC065S1 2TXCD065A RXC065S1

4CXCD050A CUBD48A 4CXCD050A4CXCD061A CCBD60A CUBD60A 4CXCD061A4TXCD050A 4TXCD050A4TXCD061A 4TXCD061A4TXCD065A 4TXCD065A

Furnace/CoilsMatrix

NOTE: For reference only on Flush Fit Applications1 Coil apex extends above case, actual height of case is 30" (Downflow application of coil is not recommended).

Page 106: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

FUR-32Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

XT 80 & CoilsMatching Matching Matching Matching

Furnace Cabinet Cased Height Uncased Height Furnace Cabinet Cased Height Uncased HeightModel Width Coils Inches Coils Inches Model Width Coils Inches Coils InchesTUD1A040A9H21A 14.5" 2CXCA018A 2CXAA018A

2CXCA024A 2CXAA024A2TXCA018A2TXCA024A2TXCA024A4CXCA018A4CXCA024A4TXCA018A4TXCA024A

TUD1B060A9H31A 17.5" 2CXCB025A 2CXAB025A TDD1B060A9H31A 17.5" 2CXCB025A 2CXAB025ATUD1B080A9H31A 17.5" 2CXCB031A 2CXAB031A TDD1B080A9H31A 17.5" 2CXCB031A 2CXAB031ATUD1B100A9H31A 17.5" 2CXCB036A 2CXAB036A 2CXCB036A 2CXAB036A

2CXCB042A 2CXAB042A 2CXCB042A 2CXAB042A2CXCB048A 2CXAB048A 2CXCB048A 2CXAB048A2TXCB025A 2TXCB025A2TXCB031A 2TXCB031A2TXCB036A 2TXCB036A2TXCB042A 2TXCB042A2TXCB048A 2TXCB048A4CXCB025A 4CXCB025A4CXCB031A 4CXCB031A4CXCB036A 4CXCB036A4CXCB042A 4CXCB042A4CXCB048A 4CXCB048A4TXCB025A 4TXCB025A4TXCB031A 4TXCB031A4TXCB036A 4TXCB036A4TXCB042A 4TXCB042A4TXCB048A 4TXCB048A

TUD1C080A9H41A 21" 2CXCC037A 2CXAC037A TDD1C100A 21" 2CXCC037A 2CXAC037ATUD1C100A9H51A 21" 2CXCC043A 2CXAC043A 2CXCC043A 2CXAC043A

2CXCC049A 2CXAC049A 2CXCC049A 2CXAC049A2CXCC060A 2CXAC060A 2CXCC060A 2CXAC060A2TXCC037A 2TXCC037A2TXCC043A 2TXCC043A2TXCC049A 2TXCC049A2TXCC054A 2TXCC054A2TXCC060A 2TXCC060A4CXCC037A 4CXCC037A4CXCC043A 4CXCC043A4CXCC049A 4CXCC049A4CXCC060A 4CXCC060A4TXCC037A 4TXCC037A4TXCC043A 4TXCC043A4TXCC049A 4TXCC049A4TXCC054A 4TXCC054A4TXCC060A 4TXCC060A

TUD1D120A9H51A 24.5" 2CXCD050A 2CXAD050A TDD1D120A 24.5" 2CXCD050A 2CXAD050ATUD1D140A9H51A 24.5" 2CXCD061A 2CXAD061A 2CXCD061A 2CXAD061A

2TXCD050A 2TXCD050A2TXCD061A 2TXCD061A2TXCD065A 2TXCD065A4CXCD050A 4CXCD050A4CXCD061A 4CXCD061A4TXCD050A 4TXCD050A4TXCD061A 4TXCD061A4TXCD065A 4TXCD065A

NOTE: For reference only on Flush Fit Applications

Furnace/CoilsMatrix

Page 107: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

FUR-33 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Furnace/CoilsMatrix

XR 80 & CoilsFurnace Cabinet Matching Matching Furnace Cabinet Matching MatchingModel Width Cased Coils Uncased Coils Model Width Cased Coils Uncased CoilsTUD040C924K 14.5" 2CXCA018A TXC018C 2CXAA018A TXA018C TDD040C924F 14.5" 2CXCA018A TXC018C 2CXAA018A TXA018CTUD040C930K 14.5" 2CXCA024A TXC024C 2CXAA024A TXA024C TDD060C936F 14.5" 2CXCA024A TXC024C 2CXAA024A TXA024CTUD060C924K 14.5" 2TXCA018A TXC030C TXA030C TDD060C936F 14.5" 2TXCA018A TXC030C TXA030CTUD060C936K 14.5" 2TXCA024A TXC035C TXA035C TDD1A040A9241A 14.5" 2TXCA024A TXC035C TXA035CTUD1A040A9241A 14.5" 4CXCA018A TXC024D TDD1A060A9241A 14.5" 4CXCA018A TXC024DTUD1A040A9301A 14.5" 4CXCA024A TXC030D TDD1A060A9361A 14.5" 4CXCA024A TXC030DTUD1A060A9301A 14.5" 4TXCA018A TXC035D 4TXCA018A TXC035DTUD1A060A9241A 14.5" 4TXCA024A CCBA18A CUBA18A 4TXCA024A

CCBA24A CUBA24ACCBA30A CUBA30ACCBA36A CUBA36A

TUD060C937K 17.5" 2CXCB025A TXC025C 2CXAB025A TDD060C937F 17.5" 2CXCB025A TXC025C 2CXAB025A TXA025CTUD080C924K 17.5" 2CXCB031A TXC031C 2CXAB031A TDD080C936F 17.5" 2CXCB031A TXC031C 2CXAB031A TXA031CTUD080C936K 17.5" 2CXCB036A TXC036C 2CXAB036A TDD080C945F 17.5" 2CXCB036A TXC036C 2CXAB036A TXA036CTUD080C948K 17.5" 2CXCB042A TXC042C 2CXAB042A TXA025C TDD100C945F 17.5" 2CXCB042A TXC042C 2CXAB042A TXA042CTUD100C936K 17.5" 2CXCB048A TXC048C 2CXAB048A TXA031C TDD1B060A9361A 17.5" 2CXCB048A TXC048C 2CXAB048A TXA048CTUD100C945K 17.5" 2TXCB025A TXC025D TXA036C TDD1B080A9361A 17.5" 2TXCB025A TXC025DTUD1B060A9361A 17.5" 2TXCB031A TXC031D TXA042C TDD1B080A9451A 17.5" 2TXCB031A TXC031DTUD1B080A9241A 17.5" 2TXCB036A TXC036D TXA048C TDD1B100A9451A 17.5" 2TXCB036A TXC036DTUD1B080A9361A 17.5" 2TXCB042A TXC031E 2TXCB042A TXC031ETUD1B080A9481A 17.5" 2TXCB048A TXC036E 2TXCB048A TXC036ETUD1B100A9361A 17.5" 4CXCB025A TXC031S 4CXCB025A TXC031STUD1B100A9451A 17.5" 4CXCB031A TXC036S 4CXCB031A TXC036S

4CXCB036A RXC025S 4CXCB036A RXC025S4CXCB042A RXC031S 4CXCB042A RXC031S4CXCB048A RXC036S 4CXCB048A RXC036S4TXCB025A CUBB24A 4TXCB025A4TXCB031A CCBB30A CUBB30A 4TXCB031A4TXCB036A CCBB36A CUBB36A 4TXCB036A4TXCB042A CCBA42A CUBB42A 4TXCB042A4TXCB048A CCBA48A CUBB48A 4TXCB048A

TUD080C960K 21" 2CXCC037A TXC037C 2CXAC037A TXA037C TDD100C948F 21" 2CXCC037A TXC037C 2CXAC037A TXA037CTUD100C948K 21" 2CXCC043A TXC043C 2CXAC043A TXA043C TDD100C954F 21" 2CXCC043A TXC043C 2CXAC043A TXA043CTUD100C960K 21" 2CXCC049A TXC049C 2CXAC049A TXA049C TDD120C954F 21" 2CXCC049A TXC049C 2CXAC049A TXA049CTUD120C954K 21" 2CXCC060A TXC060C 2CXAC060A TXA050C TDD1C100A9481A 21" 2CXCC060A TXC060C 2CXAC060A TXA050CTUD1C080A9601A 2TXCC037A TXC037E TDD1C100A9541A 21" 2TXCC037A TXC037ETUD1C100A9481A 2TXCC043A TXC054E TDD1C120A9541A 21" 2TXCC043A TXC054ETUD1C100A9601A 2TXCC049A TXC037S 2TXCC049A TXC037STUD1C120A9541A 2TXCC054A TXC054S 2TXCC054A TXC054S

2TXCC060A RXC037S 2TXCC060A RXC037S4CXCC037A RXC054S 4CXCC037A RXC054S4CXCC043A CUBC36A 4CXCC043A4CXCC049A CUBC42A 4CXCC049A4CXCC060A CCBC48A CUBC48A 4CXCC060A4TXCC037A CCBC60A CUBC60A 4TXCC037A4TXCC043A 4TXCC043A4TXCC049A 4TXCC049A4TXCC054A 4TXCC054A4TXCC060A 4TXCC060A

TUD120C960K 24.5" 2CXCD050A TXC050C 2CXAD050A TXA060C TDD120C960F 24.5" 2CXCD050A TXC050C 2CXAD050A TXA060CTUD140C960K 24.5" 2CXCD061A TXC061C 2CXAD061A TXA061C TDD140C960F 24.5" 2CXCD061A TXC061C 2CXAD061A TXA061CTUD1D100A9721A 2TXCD050A TXC065S1 TDD1D120A9601A 24.5" 2TXCD050A TXC065S1

TUD1D120A9601A 2TXCD061A RXC061S TDD1D140A9601A 24.5" 2TXCD061A RXC061STUD1D140A9601A 2TXCD065A RXC065S1 2TXCD065A RXC065S1

4CXCD050A CUBD48A 4CXCD050A4CXCD061A CCBD60A CUBD60A 4CXCD061A4TXCD050A 4TXCD050A4TXCD061A 4TXCD061A4TXCD065A 4TXCD065A

NOTE: For reference only on Flush Fit Applications1 Coil apex extends above case, actual height of case is 30" (Downflow application of coil is not recommended).

Page 108: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

FUR-34Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Furnace/CoilsMatrix

XB 80 & CoilsFurnace Cabinet Matching Matching Furnace Cabinet Matching MatchingModel Width Cased Coils Uncased Coils Model Width Cased Coils Uncased CoilsTUE040A924L 14.5" 2CXCA018A TXC018C 2CXAA018A TXA018C TDE060A936M 14.5" 2CXCA018A TXC018C 2CXAA018A TXA018CTUE060A936L 14.5" 2CXCA024A TXC024C 2CXAA024A TXA024C 2CXCA024A TXC024C 2CXAA024A TXA024C

2TXCA018A TXC030C TXA030C 2TXCA018A TXC030C TXA030C2TXCA024A TXC035C TXA035C 2TXCA024A TXC035C TXA035C4CXCA018A TXC024D 4CXCA018A TXC024D4CXCA024A TXC030D 4CXCA024A TXC030D4TXCA018A TXC035D 4TXCA018A TXC035D4TXCA024A CCBA18A CUBA18A 4TXCA024A

CCBA24A CUBA24ACCBA30A CUBA30ACCBA36A CUBA36A

TUE060A937L 17.5" 2CXCB025A TXC025C 2CXAB025A TXA025C TDE060A937M 17.5" 2CXCB025A TXC025C 2CXAB025A TXA025CTUE080A936L 17.5" 2CXCB031A TXC031C 2CXAB031A TXA031C TDE080A945M 17.5" 2CXCB031A TXC031C 2CXAB031A TXA031CTUE080A948L 17.5" 2CXCB036A TXC036C 2CXAB036A TXA036C TDE100A945M 17.5" 2CXCB036A TXC036C 2CXAB036A TXA036CTUE100A936L 17.5" 2CXCB042A TXC042C 2CXAB042A TXA042C 2CXCB042A TXC042C 2CXAB042A TXA042C

2CXCB048A TXC048C 2CXAB048A TXA048C 2CXCB048A TXC048C 2CXAB048A TXA048C2TXCB025A TXC025D 2TXCB025A TXC025D2TXCB031A TXC031D 2TXCB031A TXC031D2TXCB036A TXC036D 2TXCB036A TXC036D2TXCB042A TXC031E 2TXCB042A TXC031E2TXCB048A TXC036E 2TXCB048A TXC036E4CXCB025A TXC031S 4CXCB025A TXC031S4CXCB031A TXC036S 4CXCB031A TXC036S4CXCB036A RXC025S 4CXCB036A RXC025S4CXCB042A RXC031S 4CXCB042A RXC031S4CXCB048A RXC036S 4CXCB048A RXC036S4TXCB025A CUBB24A 4TXCB025A4TXCB031A CCBB30A CUBB30A 4TXCB031A4TXCB036A CCBB36A CUBB36A 4TXCB036A4TXCB042A CCBA42A CUBB42A 4TXCB042A4TXCB048A CCBA48A CUBB48A 4TXCB048A

TUE100A948L 21" 2CXCC037A TXC037C 2CXAC037A TXA037C TDE100A960M 21" 2CXCC037A TXC037C 2CXAC037A TXA037CTUE100A960L 21" 2CXCC043A TXC043C 2CXAC043A TXA043C 2CXCC043A TXC043C 2CXAC043A TXA043C

2CXCC049A TXC049C 2CXAC049A TXA049C 2CXCC049A TXC049C 2CXAC049A TXA049C2CXCC060A TXC060C 2CXAC060A TXA050C 2CXCC060A TXC060C 2CXCC060A TXC050C2TXCC037A TXC037E 2TXCC037A TXC037E2TXCC043A TXC054E 2TXCC043A TXC054E2TXCC049A TXC037S 2TXCC049A TXC037S2TXCC054A TXC054S 2TXCC054A TXC054S2TXCC060A RXC037S 2TXCC060A RXC037S4CXCC037A RXC054S 4CXCC037A RXC054S4CXCC043A CUBC36A 4CXCC043A4CXCC049A CUBC42A 4CXCC049A4CXCC060A CCBC48A CUBC48A 4CXCC060A4TXCC037A CCBC60A CUBC60A 4TXCC037A4TXCC043A 4TXCC043A4TXCC049A 4TXCC049A4TXCC054A 4TXCC054A4TXCC060A 4TXCC060A

TUE120A960L 24.5" 2CXCD050A TXC050C 2CXAD050A TXA060C TDE120A960M 24.5" 2CXCD050A TXC050C 2CXAD050A TXA060CTUE140A960L 24.5" 2CXCD061A TXC061C 2CXAD061A TXA061C 2CXCD061A TXC061C 2CXAD061A TXA061C

2TXCD050A TXC065S1 2TXCD050A TXC065S12TXCD061A RXC061S 2TXCD061A RXC061S2TXCD065A RXC065S1 2TXCD065A RXC065S14CXCD050A CUBD48A 4CXCD050A4CXCD061A CCBD60A CUBD60A 4CXCD061A4TXCD050A 4TXCD050A4TXCD061A 4TXCD061A4TXCD065A 4TXCD065A

NOTE: For reference only on Flush Fit Applications1 Coil apex extends above case, actual height of case is 30" (Downflow application of coil is not recommended).

Page 109: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing
Page 110: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

IDAQ-1 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

TRANE “CleanEffects™”Air Cleaner and Upgrade Kits

Table IDAQ-1-A – Air Handler – 24 Volt TRANE CleanEffects™ Whole House AirCleaner

TRANE UncratedModel Airflow CleanEffects™ Dimensions(in.) ShippingNumber Range Air Handler Width H x W x D Weight

TFD215ALAH000A 300-1200 211/2 inch 71/2 x 211/2 x 21 42TFD235ALAH000A 350-1600 231/2 inch 71/2 x 231/2 x 21 44TFD260ALAH000A 400-2000 26 inch 71/2 x 26 x 21 46

Table IDAQ-1-B – Upflow / Side Return Furnace – 24 Volt TRANE CleanEffects™TRANE Uncrated

Model Airflow CleanEffects™ Dimensions(in.) ShippingNumber Range Air Handler Width H x W x D Weight

TFD145ALFR000A 300-1200 141/2 inch1 71/2 x 141/2 x 27 39TFD175ALFR000A 300-1600 171/2 inch1 71/2 x 171/2 x 27 43TFD210ALFR000A 300-2000 21 inch2 71/2 x 21 x 27 47TFD245ALFR000A 400-2000 241/2 inch2 71/2 x 241/2 x 27 49

Table IDAQ-1-C – Downflow Furnace – 24 Volt TRANE CleanEffects™TRANE Uncrated

Model Airflow CleanEffects™ Dimensions(in.) ShippingNumber Range Air Handler Width H x W x D Weight

TFD14DALFR000A 300-1200 141/2 inch 71/2 x 141/2 x 21 33TFD17DALFR000A 300-1600 171/2 inch 71/2 x 171/2 x 21 37TFD21DALFR000A 300-2000 21 inch 71/2 x 21 x 21 41TFD24DALFR000A 400-2000 241/2 inch 71/2 x 241/2 x 21 45

Table IDAQ-1-D– Air Handler – TRANE CleanEffects™ Upgrade KitModel Airflow Perfect Fit™ ShippingNumber Range Cabinet Width Weight

TFD215ALUPGRDA 300-1200 211/2 inch 38TFD235ALUPGRDA 350-1600 231/2 inch 40TFD260ALUPGRDA 400-2000 26 inch 42

Table IDAQ-1-E – Furnace – TRANE CleanEffects™ Upgrade KitModel Airflow Perfect Fit™ ShippingNumber Range Cabinet Width Weight

TFD145ALUPGRD 300-1200 141/2 inch1 35TFD175ALUPGRD 300-1600 171/2 inch1 39TFD210ALUPGRD 300-2000 21 inch2 43TFD245ALUPGRD 400-2000 241/2 inch2 45

Table IDAQ-1-F – Downflow Furnace – TRANE CleanEffects™ Upgrade KitModel Airflow Perfect Fit™ ShippingNumber Range Cabinet Width Weight

TFD14DALUPGRD 300-1200 141/2 inch 29TFD17DALUPGRD 300-1600 171/2 inch 33TFD21DALUPGRD 300-2000 21 inch 37TFD24DALUPGRD 400-2000 241/2 inch 41

Table IDAQ-1-G — Accessories – TRANE CleanEffects™ and Upgrade KitsModel ShippingNumber Description Used With Weight

BAYTRANS12024 120 to 24 Volt Transformer All TFD Air Cleaners 61 Side return no Transition Required.2 Side return Transition Required.

TRANE CleanEffects™Air Cleaner:• TRANE CleanEffects™ removes up to

99.98% of allergens from the filtered air• Removes particles down to .3 microns in

size• Outperforms HEPA, and up to 100 times

more effective than a standard 1" filter• Constructed of heavy 18 gage metal to

protect the filter and internal electronics• Power door provides easy access to

internal components and features a filterstatus display as well as safety interlocksthat automatically shut down the powerwhen the door is opened for maintenance orcleaning

• Designed for flush fit on both sides and rearof equipment cabinet

• No transitions required on TRANECleanEffects™ applications

• Gaskets included with the air cleaner• 24 Volt input power• 10 year electronics warranty• 5 year parts warranty

TRANE CleanEffects™Upgrade Kits:• Fits any “Perfect Fit™” Air Cleaner

cabinet.• Easily convert Perfect Fit™, TFP, TFM or

TFE product to TRANE CleanEffects™ AirCleaner

• 24 Volt input power• 10 year electronics warranty.• 5 year parts warranty.

Page 111: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

IDAQ-2Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

“Perfect Fit™” Air Cleaner

Table IDAQ-2-A – Air Handler “Perfect Fit™” Dual Filtration Electronic Air Cleaner System With One (1) Inch Pre-Filter(120 Volt or 240 volt)

UncratedModel Airflow Perfect Fit™ Dimensions(in.) Shipping ReturnNumber Range Voltage Air Handler Width H x W x D Weight Air Opening33333

TFE215A9AH3 300-1400 120 211/2 inch 71/2 x 211/2 x 21 45 187/8 x187/8

TFE235A9AH3 300-1800 120 231/2 inch 71/2 x 231/2 x 21 49 207/8 x187/8

TFE260A9AH3 400-2100 120 26 inch 71/2 x 26 x 21 53 237/8 x187/8

TFE215A1AH3 300-1400 240 211/2 inch 71/2 x 211/2 x 21 45 187/8 x187/8

TFE235A1AH3 300-1800 240 231/2 inch 71/2 x 231/2 x 21 49 207/8 x187/8

TFE260A1AH3 400-2100 240 26 inch 71/2 x 26 x 21 53 237/8 x187/8

Table IDAQ-2-B – Furnace “Perfect Fit™” Dual Filtration Electronic Air Cleaner System With One (1) Inch Pre-Filter (120 Volt)Uncrated

Model Airflow Perfect Fit™ Dimensions(in.) Shipping ReturnNumber Range Voltage Air Handler Width H x W x D Weight Air Opening33333

TFE145A9FR3 300-1200 120 141/2 inch1 71/2 x141/2 x 27 44 117/8 x2413/16

TFE175A9FR3 300-1500 120 171/2 inch1 71/2 x 171/2 x 27 48 147/8 x2413/16

TFE210A9FR3 300-2000 120 21 inch2 71/2 x 21 x 27 54 183/8 x2413/16

TFE245A9FR3 400-2200 120 241/2 inch2 71/2 x 241/2 x 27 60 217/8 x2413/16

Table IDAQ-2-C — Accessories: 1" Permanent - Washable Filter (Ordered through Parts)Replacement Previous EnclosurePart Number Model Number Description Used WithFLR03831 BAYFTFR14W1A 1" PERMANENT - Washable 14-1/2FLR03832 BAYFTFR17W1A 1" PERMANENT - Washable 17-1/2FLR03833 BAYFTFR21W1A 1" PERMANENT - Washable 21FLR03834 BAYFTFR24W1A 1" PERMANENT - Washable 24-1/2

FLR03835 BAYFTAH21W1A 1" PERMANENT - Washable 21-1/2FLR03836 BAYFTAH23W1A 1" PERMANENT - Washable 23-1/2FLR03837 BAYFTAH26W1A 1" PERMANENT - Washable 261 Side return no Transition Required.2 Side return Transition Required.3 Actual opening does not include flange.

• Three sizes to flush fit TWE/4TEE/4TEP 6-wayconvertible Air Handler return.

• Four sizes to flush fit bottom of Trane furnaces.• TFP175, TFM175, TFE175 (171/2") bottom

return model can be used for a “Perfect Fit™”side return on all furnace models.

• Air Cleaners designed for flush fit on both sidesand rear of equipment cabinet.

• All service and access is from the front of the aircleaner.

• Cabinet case versatility provides three levels ofair quality.

• All Electronic Air Cleaners are shipped with a 1"washable metal pre-filter.

• “Air-Tite™” Door construction eliminatesair leaks, improves air quality and keepsoperating costs low.

• Gaskets included with the air cleaner.• Built-In Air Sensor Switch senses when air

flows through the power assembly on andoff automatically;No “Power On” relay required.

• Air Cleaner furnace models come with a120 volt power supply.

• Air Cleaner Air Handler models come with a240 volt power supply or 120 volt powersupply.

Page 112: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

IDAQ-3 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

“Perfect Fit™” Air Cleaner

Table IDAQ-3-A– Air Handler “Perfect Fit™” High Efficiency Air Cleaner With Five (5) Inch Expandable Media FilterUncrated

Model Airflow Perfect Fit™ Dimensions(in.) Shipping ReturnNumber Range Air Handler Width H x W x D Weight Air Opening33333

TFM215B0AH0 300-1400 211/2 inch 71/2 x 211/2 x 21 22 187/8 x187/8

TFM235B0AH0 300-1700 231/2 inch 71/2 x 231/2 x 21 24 207/8 x187/8

TFM260B0AH0 400-2100 26 inch 71/2 x 26 x 21 25 237/8 x187/8

Table IDAQ-3-B – Furnace “Perfect Fit™”High Efficiency Air Cleaner With Five (5) Inch Expandable Media FilterUncrated

Model Airflow Perfect Fit™ Dimensions(in.) Shipping ReturnNumber Range Air Handler Width H x W x D Weight Air Opening33333

TFM145B0FR0 300-1200 141/2 inch1 71/2 x141/2 x 27 18 117/8 x2413/16

TFM175B0FR0 300-1500 171/2 inch1 71/2 x 171/2 x 27 21 147/8 x2413/16

TFM210B0FR0 300-2000 21 inch2 71/2 x 21 x 27 24 183/8 x2413/16

TFM245B0FR0 400-2000 241/2 inch2 71/2 x 241/2 x 27 27 217/8 x2413/16

Table IDAQ-3-C – Downflow Furnace “Perfect Fit™”High Efficiency Air Cleaner With Five (5) Inch Expandable Media FilterUncrated

Model Airflow Perfect Fit™ Dimensions(in.) Shipping ReturnNumber Range Air Handler Width H x W x D Weight Air Opening33333

TFM14DA0FR0 300-1200 141/2 inch 71/2 x141/2 x 21 17 117/8 x187/8

TFM17DA0FR0 300-1500 171/2 inch 71/2 x 171/2 x 21 19 147/8 x187/8

TFM21DA0FR0 300-2000 21 inch 71/2 x 21 x 21 22 183/8x187/8

TFM24DA0FR0 400-2000 241/2 inch 71/2 x 241/2 x 21 24 217/8 x187/8

Table IDAQ-3-D – Air Handler “Perfect Fit™” Medium Efficiency Air Cleaner With One (1) Inch Pleated FilterUncrated

Model Airflow Perfect Fit™ Dimensions(in.) Shipping ReturnNumber Range Air Handler Width H x W x D Weight Air Opening33333

TFP215A0AH1 300-1200 211/2 inch 71/2 x 211/2 x 21 20 187/8 x187/8

TFP235A0AH1 300-1500 231/2 inch 71/2 x 231/2 x 21 22 207/8 x187/8

TFP260A0AH1 400-1800 26 inch 71/2 x 26 x 21 24 237/8 x187/8

Table IDAQ-3-E – Furnace “Perfect Fit™” Medium Efficiency Air Cleaner With One (1) Inch Pleated FilterUncrated

Model Airflow Perfect Fit™ Dimensions(in.) Shipping ReturnNumber Range Air Handler Width H x W x D Weight Air Opening33333

TFP145A0FR1 300-1200 141/2 inch1 71/2 x141/2 x 27 17 117/8 x2413/16

TFP175A0FR1 300-1500 171/2 inch1 71/2 x 171/2 x 27 19 147/8 x2413/16

TFP210A0FR1 400-1800 21 inch2 71/2 x 21 x 27 22 183/8 x2413/16

TFP245A0FR1 400-2000 241/2 inch2 71/2 x 241/2 x 27 25 217/8 x2413/16

1 Side return no Transition Required.2 Side return Transition Required.3 Actual opening does not include flange.

• Three sizes to flush fit TWE/4TEE/4TEP 6-wayconvertible Air Handler return.

• Four sizes to flush fit bottom of Trane furnaces.• Air Cleaners designed for flush fit on both sides

and rear of equipment cabinet.• All service and access is from the front of the air

cleaner.

• “Air-Tite™” Door construction eliminatesair leaks, improves air quality and keepsoperating costs low.

• Gaskets included with the air cleaner.

Page 113: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

IDAQ-4Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

“Perfect Fit™” Filter Accessories

Table IDAQ-4-A — Furnace Enclosure FiltersModel Enclosure ShippingNumber Description Qty Used with Weight

BAYFTFR14P4 1" Pleated Filter 4 / Box 14 1/2 3BAYFTFR17P4 1" Pleated Filter 4 / Box 17 1/2 3BAYFTFR21P4 1" Pleated Filter 4 / Box 21 3BAYFTFR24P4 1" Pleated Filter 4 / Box 24 1/2 3BAYFTFR14M2 5" Media Filter 2 / Box 14 1/2 5BAYFTFR17M2 5" Media Filter 2 / Box 17 1/2 5BAYFTFR21M2 5" Media Filter 2 / Box 21 5BAYFTFR24M2 5" Media Filter 2 / Box 24 1/2 6BAYFTFREXM2 Expandable 5" Cartridge Media Filter 2 / Box 14 1/2-24 1/2 5

Table IDAQ-4-B — Air Handler Enclosure FiltersModel Enclosure ShippingNumber Description Qty Used with Weight

BAYFTAH21P4 1" Pleated Filter 4 / Box 21 1/2 3BAYFTAH23P4 1" Pleated Filter 4 / Box 23 1/2 3BAYFTAH26P4 1" Pleated Filter 4 / Box 26 3BAYFTAH21M2 5" Media Filter 2 / Box 21 1/2 5BAYFTAH23M2 5" Media Filter 2 / Box 23 1/2 5BAYFTAH26M2 5" Media Filter 2 / Box 26 6BAYFTAHEXM2 Expandable 5" Cartridge Media Filter 2 / Box 21 1/2-26 5

Table IDAQ-4-C — Downflow Cartridge MediaModel Enclosure ShippingNumber Description Qty Used with Weight

BAYFTDN14M2 5" Downflow Media Filter 2/ Box 14 D 5BAYFTDN17M2 5" Downflow Media Filter 2/ Box 17 D 5BAYFTDN21M2 5" Downflow Media Filter 2/ Box 21 D 5BAYFTDN24M2 5" Downflow Media Filter 2/ Box 24 D 5

Table IDAQ-4-D — Furnace FramesModel Enclosure ShippingNumber Description Qty Used with Weight

BAYFRAME1451 Expandable Media Filter 1/ Box 14 1/2 5BAYFRAME1751 Expandable Media Filter 1/ Box 17 1/2 5BAYFRAME2101 Expandable Media Filter 1/ Box 21 5BAYFRAME2451 Expandable Media Filter 1/ Box 24 1/2 5

Table IDAQ-4-E — Air Handler FramesModel Enclosure ShippingNumber Description Qty Used with Weight

BAYFRAME2151 Expandable Media Frame 1/ Box 21 5BAYFRAME2351 Expandable Media Frame 1/ Box 23 1/2 5BAYFRAME2601 Expandable Media Frame 1/ Box 26 51 Includes one filter.

Page 114: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

IDAQ-5 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

“Perfect Fit™”

Table IDAQ-5-A — Air Handler FiltersAIR HANDLER MODEL NUMBER

1" Pleated Filter 5" Media Filter Electronic Filter CleanEffects™ A BTFP215A0AH0 TFM215A0AH0 TFE215A1AH0, A9AH0 TFD215ALAH000A 21-1/2 18-7/8TFP235A0AH0 TFM235A0AH0 TFE235A1AH0, A9AH0 TFD235ALAH000A 23-1/2 20-7/8TFP260A0AH0 TFM260A0AH0 TFE260A1AH0, A9AH0 TFD260ALAH000A 26 23-7/8

Side View

Topof

Cabinet

Page 115: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

IDAQ-6Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

“Perfect Fit™”

Table IDAQ-6-A — Upflow Furnace FiltersFURNACE MODEL NUMBER

1" Pleated Filter 5" Media Filter Electronic Filter CleanEffects™ A BTFP145A0FR0 TFM145A0FR0 TFE145A9FR0 TFD145ALFR000A 14-1/2 11-7/8TFP175A0FR0 TFM175A0FR0 TFE175A9FR0 TFD175ALFR000A 17-1/2 14-7/8TFP210A0FR0 TFM210A0FR0 TFE210A9FR0 TFD210ALFR000A 21 18-3/8TFP245A0FR0 TFM245A0FR0 TFE245A9FR0 TFD245ALFR000A 24-1/2 21-7/8

Side View

Topof

Cabinet

Table IDAQ-6-B — Downflow Furnace FiltersFURNACE MODEL NUMBER

5" Media Filter ifD Filter A BTFM14DA0FR0 TFD14DALFR000A 14-1/2 11-7/8TFM17DA0FR0 TFD17DALFR000A 17-1/2 14-7/8TFM21DA0FR0 TFD21DALFR000A 21 18-3/8TFM24DA0FR0 TFD24DALFR000A 24-1/2 21-7/8

OUTLINE DRAWING UPFLOW FURNACE MODELSOUTLINE DRAWINGDOWNFLOW FURNACE MODELS

Side View

Topof

Cabinet

Page 116: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

IDAQ-7 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

HumidifiersFan Powered and Bypass

THUMD500A• Flow Through Fan Powered Humidifier• High Performance Humidifier Delivers up to

18 Gallons per Day• Automatic Humidifier Control with O.D.

Sensor for up to 50% more Humidity• Front Cover Access for easy replacement of

humidifier pad.• Aluminum Humidifier Pad Treated with

Ceramic Clay for Enhanced Pad Perfor-mance

• Reliable Brass Solenoid Valve w/StainlessSteel Valve Seat

• UV Resistant Cabinet and Scale ControlInsert

• Saddle Valve• Polyslate Gray Housing matches Furnace

Cabinet Color• Decorative nameplate• 120V Power Line Cord

Table IDAQ-7-A — Specifications: Humidifier with HumidistatModel Mfg. ShippingNumber Description Used With Plant WeightTHUMD500APA00A14 Fan Powered Humidifer All Furnace Models TY 1THUMD300ABA00A2 Large Bypass Humidifier All Furnace Models TY 1THUMD200ABM00A3 Small Bypass Humidifier All Furnace Models TY 11 Includes Automatic Humidifier Control (Duct Mount Only)2 Includes Automatic Humidifier Control (Duct Mount Only) and 120/24V transformer3 Includes Manual Humidifier Control and 120/24V transformer4 Not applicable for horizontal installations

Table IDAQ-7-B — AccessoriesModel Mfg. ShippingNumber Description Used With Plant WeightBAYPAD02A1310A Large Humidifier Pad 13”x10” THUMD500,300A TY 1BAYPAD01A1010A Small Humidifier Pad 9-7/8”x9-5/8” THUMD200A TY 1TCONTH01AAUTOA Automatic Humidifier Control THUMD200A TY 1BAYRLY10ASENSA Current Sensing Relay All TY 1BAYPLT01AMHCOA Adapter Plate (Duct Mount) Manual Humidifier Control TY 1

THUMD500A

THUMD200A, 300A

THUMD200,300A

• THUMD300A Bypass delivers up to 17Gallons per day

• THUMD200A delivers up to 12 Gallons perday.

• THUMD300A Automatic Humidifier Controland O.D. Sensor for up to 50% moreHumidity

• THUMD200A Manual Humidifier Control• UV Resistant Cabinet and Scale Control

Insert• Front Cover Access for easy replacement of

humidifier pad.• Aluminum Humidifier Pad Treated with

Ceramic Clay for Enhanced Pad Perfor-mance

• Reliable Brass Solenoid Valve w/StainlessSteel Valve Seat

• Field Convertible Duct Connection, Left orRight Side

• Built in Summer / Winter Damper• UV Resistant Cabinet and Scale Control

Insert• Saddle Valve• Polyslate Gray Housing matches Furnace

Cabinet Color• Decorative nameplate• 120 V Primary• 24V Secondary, 10VA

Page 117: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

IDAQ-8Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

HumidifiersFan Powered and Bypass

THUMD500PA00A FAN POWERED HUMIDIFIER

THUMD300AB00A LARGE BYPASS HUMIDIFIER

THUMD200AB00A SMALL BYPASS HUMIDIFIER

Page 118: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

IDAQ-9 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

HumidifiersFan Powered and Bypass

TCONTH01AAUTOA AUTOMATIC HUMIDIFIER CONTROLMANUAL HUMIDIFIER CONTROL(SHIP WITH THUMD200AB00A)

SUGGESTED BYPASS HUMIDFIER LOCATIONS

OPTIONAL FLUENOT ALL MODELS

RETURN AIR

SUPPLY AIR

Page 119: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

IDAQ-10Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

FreshEffects™ Energy RecoveryVentilator (ERV)

• FreshEffects™ ERV technology for allseasons and climates

• Static plate energy transfer core for efficienttransfer of heat and moisture

• Passive defrost - condensate drain notrequired

• Balancing dampers not required• Multi position mounting• Percent Timer (PT) control included with

ERV for simple, automatic operation• Optional push button control for use with PT

control• Cam action door latches for quick service

access• Heavy gauge, powder painted steel cabinet• Permanently lubricated motor bearings

Table IDAQ-10-A — Specifications: ERVNominal Uncrated

Model Airflow Power Dimensions (In.) ShippingNumber (CFM) Supply H W D WeightTERVR100A9P00A1 130 120/1/60 20-1/8 28-3/4 13 58TERVR200A9P00A1 200 120/1/60 20-1/8 28-3/4 23-7/8 80TERVR300A9P00A12 300 120/1/60 20-1/8 28-3/4 23-7/8 881 Percent Timer Control included with the ERV2 Available in April 2006

Table IDAQ-10-B — Specifications: ERVModel Apparent Sensible Sensible Recovery Latent TotalNumber Effectiveness(32°F) Effectiveness(32°F) Recovery (32°F) Recovery (32°F)TERVR100A9P00A 80% @ 120 cfm 84% @ 120 cfm 73% @ 251 cfm 51% @ 63 cfmTERVR200A9P00A 72% @ 120 cfm 77% @ 120 cfm 64% @ 251 cfm 59% @ 63 cfmTERVR300A9P00A2 44% @ 120 cfm 63% @ 120 cfm 40% @ 251 cfm 31% @ 252 cfm2 Available in April 2006

Table IDAQ-10-C — Optional AccessoriesModel ShippingNumber Description Used With WeightTCONTV10APBC0A Point of Use Push Button Control ERV models 100, 200, 300 1BAYFLT10A1010A Filters - 2 per pack ERV models 100 1BAYFLT20A1020A Filters - 2 per pack ERV models 200, 300 1BAYWHT10AVENTA3 6 inch White Vinyl Ventilation Hood ERV models 100, 200 1BAYBRN10AVENTA3 6 inch Brown Vinyl Ventilation Hood ERV models 100, 200 1BAYGLV10AVENTA3 8 inch Galvenized Ventilation Hood ERV models 300 23 Qty 1

• 6” and 8” double collar duct connections forTERVR100 and 200

• 8” round compatible duct connection forTERVR300

• Closed cell foam gasketing for insulationintegrity

• 1” duct board insulation withcleanable foil face

• May be installed in conditioned andunconditioned spaces

• Cabinet / Door color: Trane Polyslate Gray /Tarpaulin Gray

• 5 year limited warranty on parts• 10 year limited warranty on energy

transfer core• Optional extended warranty

Page 120: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PC-1 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Package CoolingConvertible 1½ through 5 Tons

Table PC-1-A — 4TCX- XL13c - Convertible Package Cooling - R-410ACabinet

Model Shipping Max Sound Dimensions (in.)Number Capacity SEER/EER Weight MCA Fuse Rating H x W x L

4TCX – 208/230/1/604TCX3018A1000A 18,800 13.65/11.20 444 10.1 15 69 36 x 51 x 434TCX3024A1000A 24,800 13.30/11.00 444 13.6 20 72 36 x 51 x 434TCX3030A1000A 29,800 13.15/11.65 445 21.7 35 72 36 x 51 x 434TCX3036A1000A 36,200 13.30/11.00 450 23.2 35 72 36 x 51 x 434TCX3042A1000A 43,500 13.05/11.00 523 27.9 45 72 38 x 46 x 614TCX3048A1000A 46,500 13.15/11.00 607 31.1 50 72 38 x 46 x 614TCX3060A1000A 60,500 13.40/11.05 610 43.3 60 72 40 x 46 x 614TCX – 208/230/3/604TCX3036A3000A 36,200 13.30/11.00 450 18.2 30 72 36 x 51 x 434TCX3048A3000A 46,500 13.14/11.00 607 23.6 35 72 38 x 46 x 614TCX3060A3000A 60,500 13.40/11.05 610 31.5 50 72 40 x 46 x 614TCX – 460/3/604TCX3036A4000A 36,200 13.30/11.00 450 8.7 15 72 36 x 51 x 434TCX3048A4000A 46,500 13.15/11.00 607 11.7 15 72 38 x 46 x 614TCX3060A4000A 60,500 13.40/11.00 610 19.3 25 79 40 x 46 x 61

• Architecturally integrated louvers and cornerguards deliver durable protection, extrasafety, and great looks.

• Weather Beater Top contoured for greatappearance and reinforced for strength.

• Ultra quiet operation provides best-in-classperformance with barely noticeable soundlevels.

• Appliance grade finish of durable powderpaint baked on both sides of the panels.

• Exclusive Climatuff® high efficiencycompressor with internal overload protection.

• Aerospace ducted outdoor fan with a highefficiency motor for quiet and reliableoperation.

• Composite Vortica® blower provides betterairflow and less sound while using lessenergy.

• Spine Fin™ outdoor coil for long lastingperformance and durability.

• Right side electrical service for high and lowvoltage lines.

• Rugged steel basepan features deep drawnduct connections and emergency drains.

• Steeply sloped composite drainpan willempty fast and never rust.

• Ships in horizontal configuration and convertsquickly for downflow.

• Complete set of customized electric heatersdesigned for all models. Features a polarizedplug for easy installation.

• Optional filter rack kits fit inside the unit.Available for 1" or 2" media.

• Non-bleed expansion valves on indoor andoutdoor coils.

• Direct drive 2 and 3 speed indoor blowermotors.

• Pressure taps easily accessed and protectedinside compressor compartment.

• Easy access liquid line tap inside compressorcompartment.

• Standard operation to 55°F as manufactured.• Low ambient cooling to 0°F with kit.• UL approved and listed.• 20 year heat exchanger, 10 year compres-

sor, 10 year outdoor coil, and 5 years otherparts limited warranty.(Residential Use Only)

• Optional extended warranty.

For information on Roof Curbs and Roof Curb Adaptors,please refer to the Accessories/Information Tab.

Page 121: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PC-2Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Package CoolingConvertible 1½ through 5 Tons

4TCX3018A through 4TCX3036A

For information on Roof Curbs andRoof Curb Adaptors, please refer tothe Accessories/Information Tab.

Page 122: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PC-3 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Package CoolingConvertible 1½ through 5 Tons

4TCX3018A through 4TCX3036A

For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.

Page 123: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PC-4Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Package CoolingConvertible 1½ through 5 Tons

4TCX3042A through 4TCX3060A

For information on Roof Curbs andRoof Curb Adaptors, please refer tothe Accessories/Information Tab.

Page 124: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PC-5 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Package CoolingConvertible 1½ through 5 Tons

4TCX3042A through 4TCX3060A

For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.

Page 125: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PC-6Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Table PC-6-A — 4TCC–XB13c - Convertible Package Cooling - R-410ACabinet

Model Shipping Max Sound Dimensions (in.)Number Capacity SEER/EER Weight MCA Fuse Rating H x W x L

4TCC – 208/230/1/604TCC3018A1000A 18,000 13.0/11.00 444 10.1 15 74 36 x 49 x 424TCC3024A1000A 23,000 13.0/11.00 444 13.6 20 76 36 x 49 x 424TCC3030A1000A 28,000 13.0/11.00 445 21.7 35 75 36 x 49 x 424TCC3036A1000A 35,000 13.0/11.00 450 23.2 35 76 36 x 49 x 424TCC3042A1000A 40,000 13.0/11.00 523 27.9 45 78 38 x 59 x 444TCC3048A1000A 46,500 13.0/11.00 607 31.1 50 80 38 x 59 x 444TCC3060A1000A 58,000 13.0/11.00 610 43.3 60 79 40 x 59 x 444TCC – 208/230/3/604TCC3036A3000A 35,000 13.0/11.00 450 18.2 30 76 36 x 49 x 424TCC3048A3000A 46,500 13.0/11.00 607 23.6 35 80 38 x 59 x 444TCC3060A3000A 58,000 13.0/11.00 610 31.5 50 79 40 x 59 x 444TCC – 460/3/604TCC3036A4000A 35,000 13.0/11.00 450 8.7 15 76 36 x 49 x 424TCC3048A4000A 46,500 13.0/11.00 607 11.7 15 80 38 x 59 x 444TCC3060A4000A 58,000 13.0/11.00 610 19.3 25 79 40 x 59 x 44

Package CoolingConvertible 1½ through 5 Tons

• All steel louvers and cabinet for rugged, longlasting protection.

• Weather Beater Top contoured for greatappearance and reinforced for strength.

• Quiet operation delivers great in-homecomfort with minimal sound.

• Appliance grade finish of durable powderpaint baked on both sides of the panels.

• Exclusive Climatuff® high efficiencycompressor with internal overload protec-tion.

• High efficiency outdoor fan motor for quietand reliable operation.

• Composite Vortica® blower provides betterairflow and less sound while using lessenergy.

• Spine Fin™ outdoor coil for long lastingperformance and durability.

• Right side electrical service for high and lowvoltage lines.

• Rugged steel basepan features deep drawnduct connections and emergency drains.

• Steeply sloped composite drainpan willempty fast and never rust.

• Ships in horizontal configuration andconverts quickly for downflow.

• Complete set of customized electric heatersdesigned for all models. Features a polarizedplug for easy installation.

• Optional filter rack kits fit inside the unit.Available for 1" or 2" media.

• Non-bleed expansion valves on indoor andoutdoor coils.

• Direct drive 2 and 3 speed indoor blowermotors.

• Pressure taps easily accessed and protectedinside compressor compartment.

• Easy access liquid line tap inside compressorcompartment.

• Standard operation to 55°F as manufactured.• Low ambient cooling to 0°F with kit.• UL approved and listed.• 5 year compressor and 5 years other parts

limited warranty. (Residential Use Only)• Optional extended warranty.

For information on Roof Curbs and Roof Curb Adaptors,please refer to the Accessories/Information Tab.

Page 126: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PC-7 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Package CoolingConvertible 1½ through 5 Tons

4TCC3018A through 4TCC3036A

For information on Roof Curbs andRoof Curb Adaptors, please refer tothe Accessories/Information Tab.

Page 127: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PC-8Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Package CoolingConvertible 1½ through 5 Tons

4TCC3018A through 4TCC3036A

For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.

Page 128: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PC-9 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Package CoolingConvertible 1½ through 5 Tons

4TCC3042A through 4TCC3060A

For information on Roof Curbs andRoof Curb Adaptors, please refer tothe Accessories/Information Tab.

Page 129: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PC-10Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Package CoolingConvertible 1½ through 5 Tons

4TCC3042A through 4TCC3060A

For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.

Page 130: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PC-11 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Package CoolingConvertible 1½ through 5 Tons

4TCX3 4TCC3Table PC-11-A — Accessories 1½-5 1½-5BAYADAP050A ...... Adapter Curb (Cabinet A/B) ............................................................................................................................ 1½-3 1½-3BAYADAP051A ...... Adapter Curb (Cabinet C) ............................................................................................................................... 1½-3 1½-3BAYADAP052A ...... Adapter Curb (Cabinet A/B) ............................................................................................................................ 3½-5 3½-5BAYADAP053A ...... Adapter Curb (Cabinet C) ............................................................................................................................... 3½-5 3½-5BAYADAP054A ...... Adapter Curb (Cabinet D) ............................................................................................................................... 3½-5 3½-5BAYCCHT101A ..... Crankcase Heater (230V) .............................................................................................................................. 1½-2 1½-2BAYCCHT102A ..... Crankcase Heater (230V) .............................................................................................................................. 2½-5 2½-5BAYCCHT104A ..... Crankcase Heater (460V) .............................................................................................................................. 3,4,5 3,4,5BAYCOVR112A ..... 12" Duct Shourd (Covers Horizontal Ducts)0 ................................................................................................. 1½-3 1½-3BAYCOVR118A ..... 18" Duct Shourd (Covers Horizontal Ducts)0 ................................................................................................. 1½-3 1½-3BAYCURB050A ..... Flat Roof Curb (Insulated)5 ........................................................................................................................... 1½- 3 1½- 3BAYCURB051A ..... Flat Roof Curb (Insulated)6 ........................................................................................................................... 3½-5 3½-5BAYDMPR101A ..... 2-Position Motorized Damper ......................................................................................................................... 1½- 3 1½- 3BAYDMPR102A ..... 2-Position Motorized Damper ......................................................................................................................... 3½-5 3½-5BAYECON101A ..... Economizer with Barometric Relief1347 .................................................................................................... 1½- 3 1½- 3BAYECON102A ..... Economizer with Barometric Relief1347 .................................................................................................... 3½-5 3½-5BAYECON200A ..... Economizer (Horizontal)137 ........................................................................................................................ 1½- 3 1½- 3BAYECON201A ..... Economizer (Horizontal)137 ........................................................................................................................ 3½-5 3½-5BAYENTH100A ..... Enthalpy Control Kit3 ..................................................................................................................................... ✔ ✔BAYEXMK001A ..... Extreme Conditions Mounting Kit (Used on BAYCURB & BAYADAP) ............................................................. ✔ ✔BAYEXMK002A ..... Extreme Conditions Mounting Kit (Used on BAYUTIL) .................................................................................... ✔ ✔BAYEXMK003A ..... Extreme Conditions Mounting Kit (Used on Slab Mounts) ............................................................................... ✔ ✔BAYFLTR101A ....... 1-2" Filter Frame1 .......................................................................................................................................... 1½- 3 1½- 3BAYFLTR201A ....... 1-2" Filter Frame1 .......................................................................................................................................... 3½-4 3½-4BAYLIFT002BA ..... Lifting Lug Kit ................................................................................................................................................. ✔ ✔BAYLOAM011A ..... Evaporator Defrost Control Kit ........................................................................................................................ ✔ ✔BAYLOAM105A ..... Low Ambient Control Kit ................................................................................................................................. ✔ ✔BAYOSAH001A ..... Manual Fresh Air Damper14 ........................................................................................................................ 1½-3 1½-3BAYOSAH002A ..... Manual Fresh Air Damper14 ........................................................................................................................ 3½-5 3½-5BAYQSTK300A ..... Quick Start Kit .............................................................................................................................................. 1 Phase Only 1 Phase OnlyBAYSQRD001A ..... 16" Round Duct Adapter9 ............................................................................................................................. 1½-3 1½-3BAYSQRD002A ..... 18" Round Duct Adapter9 ............................................................................................................................. 1½-5 1½-5BAYUTIL101A ....... Roof Curb Utility Extension Kit ........................................................................................................................ 1½-3 1½-3BAYUTIL102A ....... Roof Curb Utility Extension Kit ........................................................................................................................ 3½-5 3½-51 Must use filter frame when economizer/fresh air kit is used.2 Ships knocked down.3 Dry bulb control standard with economizer.4 Downflow Only.5 Full perimeter curb for 4TC*3018-036A.6 Full perimeter curb for 4TC*3042-060A.7 2-Stage thermostat provides additional energy savings if simultaneous economizer and compressor operation is expected.8 Do not use with programmable thermostats.9 It is the responsibility of the installing dealer to properly size the ductwork for each specific application.0 BAYCOVR112,118A will not cover BAYSQRD002A applications

For information on Roof Curbs and Roof Curb Adaptors,please refer to the Accessories/Information Tab.

Page 131: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PC-12Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Package CoolingConvertible 1½ through 5 Tons

Table PH-12-A — Supplementary Heaters – Separate power source /power entry requiredModel ShippingNumber Description Used With WeightBAYHTRV105A 3.76/5.0 kW Heater (208/240V 1PH) 4TC*3018-060A1 9BAYHTRV110A 7.50/10.0 kW Heater (208/240V 1PH) 4TC*3024-060A1 10BAYHTRV115A 11.27/15.00 kW Heater (208/240V 1PH) 4TC*3030-060A1 14BAYHTRV120A 15.00/20.0 kW Heater (208/240V 1PH) 4TC*3048-060A1 14BAYHTRV305A 3.76/5.0 kW Heater (208/240V 3PH) 4TC*3018-060A3 9BAYHTRV310A 7.50/10.0 kW Heater (208/240V 3PH) 4TC*3024-060A3 10BAYHTRV315A 11.27/15.00 kW Heater (208/240V 3PH) 4TC*3030-060A3 14BAYHTRV320A 15.0/20.0 kW Heater (208/240V 3PH) 4TC*3048-060A3 14BAYHTRV405A 3.76/5.0 kW Heater (460V 3PH) 4TC*3018-060A4 9BAYHTRV410A 7.50/10.0 kW Heater (460V 3PH) 4TC*3024-060A4 10BAYHTRV415A 11.27/15.00 kW Heater (460V 3PH) 4TC*3030-060A4 14BAYHTRV420A 15.0/20.0 kW Heater (460V 3PH) 4TC*3048-060A4 14

Table PH-12-B — Single Power Entry Kit/Heater Matrix:Single Power Heater Unit ShippingEntry Kit11111 Model Model WeightBAYSPEK060A BAYHTRV105A 4TC*3018-048A1 3

BAYHTRV110A 4TC*3024-048A1BAYSPEK061A BAYHTRV305A 4TC*3036-060A3 7

BAYHTRV310A 4TC*3036-048A3BAYHTRV315A 4TC*3036-060A3BAYHTRV405A 4TC*3036-060A4BAYHTRV410A 4TC*3036-060A4BAYHTRV415A 4TC*3036-060A4BAYHTRV420A 4TC*3048-060A4

BAYSPEK062A BAYHTRV105A 4TC*3060A1 7BAYHTRV110A 4TC*3060A1

BAYSPEK063A BAYHTRV115A 4TC*3030-060A1 7BAYHTRV120A 4TC*3048-060A1

BAYSPEK064A BAYHTRV320A 4TC*3048-060A3 61 All necessary fuses are included in kit

For information on Roof Curbs and Roof Curb Adaptors,please refer to the Accessories/Information Tab.

Page 132: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PC-13 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

PHASED OUT

Package CoolingConvertible 2 through 5 Tons

TCY — XL 1400 TCX — XL 1200

XL1400

PHASED OUT

Table PC-13-A — TCY – XL 1400 Convertible Package CoolingCooling Cabinet Supply/Return Supply /Return Shipping

Unit Capacity Dimensions (in.) Downflow Horizontal Weight Max SoundModel No. SEER/EER* (Btuh) H x W x L W x L H x W (Ibs.) MCA* Fuse* Rating Compressor

TCY – 208-230/1/60

TCY024G100B 14.00/12.00 24,000 29 x 36 x 56 (B) 171/2 x 10 189/16 x 111/16 371 15.9 25 80 R1TCY030G100A 13.00/11.00 30,600 29 x 36 x 56 (B) 171/2 x 10 189/16 x 111/16 382 21.4 30 80 R2TCY036G100A 14.10/12.00 36,000 29 x 36 x 64 (C) 171/2 x 10 189/16 x 111/16 448 24.8 35 80 R2TCY042G100A 14.00/11.70 41,500 29 x 36 x 64 (C) 171/2 x 10 189/16 x 111/16 448 26.7 40 80 R2TCY048G100A 14.40/12.20 49,000 33 x 45 x 65 (D) 20 x 14 211/16 x 151/16 561 32.7 50 84 R2TCY060G100A 13.00/11.00 61,000 33 x 45 x 65 (D) 20 x 14 211/16 x 151/16 566 46.8 60 84 S

Table PC-13-B — TCX – XL 1200 Convertible Package CoolingCooling Cabinet Supply/Return Supply /Return Shipping

Unit Capacity Dimensions (in.) Downflow Horizontal Weight Max SoundModel No. SEER/EER* (Btuh) H x W x L W x L H x W (Ibs.) MCA* Fuse* Rating Compressor

TCX – 208-230/1/60

TCX024G100B 12.00/10.50 24,500 25 x 36 x 56 (A) 171/2 x 10 189/16 x 111/16 351 14.6 20 80 R1TCX030G100A 12.05/10.90 30,600 29 x 36 x 56 (B) 171/2 x 10 189/16 x 111/16 363 21.2 30 80 STCX036G100A 12.05/10.50 37,000 29 x 36 x 56 (B) 171/2 x 10 189/16 x 111/16 374 24.4 40 80 STCX042G100A 12.05/10.55 43,000 29 x 36 x 56 (B) 171/2 x 10 189/16 x 111/16 384 26.8 40 80 STCX048G100A 12.50/11.45 48,000 33 x 45 x 65 (D) 20 x 14 211/16 x 151/16 480 31.9 50 84 STCX060G100A 12.05/10.55 61,500 33 x 45 x 65 (D) 20 x 14 211/16 x 151/16 507 45.0 70 84 STCX – 208-230/3/60

TCX036G300A 12.05 37,000 29 x 36 x 56 (B) 171/2 x 10 189/16 x 111/16 374 17.4 25 80 STCX042G300A 12.05 43,000 29 x 36 x 56 (B) 171/2 x 10 189/16 x 111/16 384 19.9 30 80 STCX048G300A 12.50 48,000 33 x 45 x 65 (D) 20 x 14 211/16 x 151/16 480 24.5 35 84 STCX060G300A 12.05 61,500 33 x 45 x 65 (D) 20 x 14 211/16 x 151/16 507 30.6 45 84 STCX – 460/3/60

TCX036G400A 12.05 37,000 29 x 36 x 56 (B) 171/2 x 10 189/16 x 111/16 374 10.0 15 80 STCX048G400A 12.50 48,000 33 x 45 x 65 (D) 20 x 14 211/16 x 151/16 480 15.4 20 84 STCX060G400A 12.05 61,500 33 x 45 x 65 (D) 20 x 14 211/16 x 151/16 507 15.1 20 84 S

* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.Compressor Types are: R1 = Reciprocating One Cylinder, R2 = Reciprocating Two Cylinder, S = Scroll

For information on Roof Curbs and Roof Curb Adaptors,please refer to the Accessories/Information Tab.

Page 133: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PC-14Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

PHASED OUT

PHASED OUT

Table PC-14-A — TCP – XE 1200 Convertible Package CoolingCooling Cabinet Supply/Return Supply /Return Shipping

Unit Capacity Dimensions (in.) Downflow Horizontal Weight Max SoundModel No. SEER/EER* (Btuh) H x W x L W x L H x W (Ibs.) MCA* Fuse* Rating Compressor

TCP – 208-230/1/60TCP024F100B 12.10/10.50 24,500 25 x 36 x 56 (A) 171/2 x 10 189/16 x 111/16 351 14.6 20 80 R1TCP030F100A 12.00/10.90 30,000 29 x 36 x 56 (B) 171/2 x 10 189/16 x 111/16 363 21.2 30 80 STCP036F100A 12.00/10.50 36,000 29 x 36 x 56 (B) 171/2 x 10 189/16 x 111/16 374 24.4 40 80 STCP042F100A 12.00/11.45 42,000 29 x 36 x 56 (B) 171/2 x 10 189/16 x 111/16 384 26.8 40 80 STCP048F100A 12.20/11.45 47,000 33 x 45 x 65 (D) 20 x 14 211/16 x 151/16 480 31.9 50 84 STCP060F100A 12.00/10.55 60,000 33 x 45 x 65 (D) 20 x 14 211/16 x 151/16 507 45 70 84 STCP – 208-230/3/60TCP036F300A 12.00 36,000 29 x 36 x 56 (B) 171/2 x 10 189/16 x 111/16 374 17.4 25 80 STCP042F300A 12.00 42,000 29 x 36 x 56 (B) 171/2 x 10 189/16 x 111/16 384 19.9 30 80 STCP048F300A 12.20 47,000 33 x 45 x 65 (D) 20 x 14 211/16 x 151/16 480 24.5 35 84 STCP060F300A 12.00 60,000 33 x 45 x 65 (D) 20 x 14 211/16 x 151/16 507 30.6 45 84 STCP – 460/3/60TCP036F400A 12.00 36,000 29 x 36 x 56 (B) 171/2 x 10 189/16 x 111/16 374 10 15 80 STCP048F400A 12.20 47,000 33 x 45 x 65 (D) 20 x 14 211/16 x 151/16 480 15.4 20 84 STCP060F400A 12.00 60,000 33 x 45 x 65 (D) 20 x 14 211/16 x 151/16 507 15.1 20 84 S

TCP — XE 1200TCC — XE 1000

Package CoolingConvertible 1½ through 5 Tons

* Information subject to change. Please confirm with currentProduct Data/Service Facts for current factory production.Note: TCC-F models currently manufactured with sloped drain pans.Compressor Types are: R1 = Reciprocating One Cylinder, R2 = Reciprocating Two Cylinder, S = Scroll

Table PC-14-B — TCC – XE 1000 Convertible Package CoolingCooling Cabinet Supply/Return Supply /Return Shipping

Unit Capacity Dimensions (in.) Downflow Horizontal Weight Max SoundModel No. SEER/EER* (Btuh) H x W x L W x L H x W (Ibs.) MCA* Fuse* Rating Compressor

TCC – 208-230/1/60TCC018F100B 10.00/9.35 18,000 25 x 36 x 55 (A) 171/2 x 10 189/16 x 111/16 319 15.0 20 80 R1TCC024F100B 10.00/9.10 23,400 25 x 36 x 55 (A) 171/2 x 10 189/16 x 111/16 327 17.7 25 80 R1TCC030F100B 10.00/9.10 29,800 29 x 36 x 55 (B) 171/2 x 10 189/16 x 111/16 354 22.7 35 80 R1TCC042F100B 10.00/8.60 40,500 29 x 36 x 55 (B) 171/2 x 10 189/16 x 111/16 389 31.2 50 80 R2TCC048F100B 10.00/9.25 48,000 33 x 45 x 64 (D) 20 x 14 211/16 x 151/16 513 37.0 55 84 R2TCC060F100B 10.00/9.20 60,000 33 x 45 x 64 (D) 20 x 14 211/16 x 151/16 547 43.9 70 84 R2

TCC – 208-230/3/60 - LIMITED AVAILABILITY 3 PHASE ONLY, 2006.TCC036F300B 10.00 35,400 29 x 36 x 55 (B) 171/2 x 10 189/16 x 111/16 369 19.9 30 80 R1/2TCC042F300B 10.00 40,500 29 x 36 x 55 (B) 171/2 x 10 189/16 x 111/16 389 22.9 35 80 R2TCC048F300B 10.00 48,000 33 x 45 x 64 (D) 20 x 14 211/16 x 151/16 513 27.0 40 84 R2TCC060F300B 10.00 60,000 33 x 45 x 64 (D) 20 x 14 211/16 x 151/16 547 31.0 45 84 R2

TCC – 460/3/60 - LIMITED AVAILABILITY 3 PHASE ONLY, 2006.TCC036F400B 10.00 35,400 29 x 36 x 55 (B) 171/2 x 10 189/16 x 111/16 369 10.5 15 80 R1/2TCC048F400B 10.00 48,000 33 x 45 x 64 (D) 20 x 14 211/16 x 151/16 513 12.7 20 84 R2TCC060F400B 10.00 60,000 33 x 45 x 64 (D) 20 x 14 211/16 x 151/16 547 16.3 25 84 R2

For information on Roof Curbs andRoof Curb Adaptors, please refer tothe Accessories/Information Tab.

Page 134: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PC-15 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

PHASED OUT

PHASED OUT

PHASED OUT

Package CoolingConvertible 1½ through 5 Tons

C

BA

E

DD

F

ML

J

K ML

YY

N

X X

PHORIZONTALSUPPLYOPENING DOWNFLOW

SUPPLYOPENING

HORIZONTALRETURN OPENING

DOWNFLOWRETURN OPENING

CONDENSATE DRAIN19 MM (3/4") FEMALE NPT

EG

H

35 MM(1 3/8")

29 MM(1 1/8")

76 MM(3")

EVAPORATOR COIL &BLOWER PANEL

ECONOMIZER/FILTERACCESS PANEL

CENTER OFGRAVITY

SUPPLY &RETURN PANEL

Note: TCC-F models currently manufactured with sloped drain pans.

PHASED OUT

For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.

Table PC-15-A — TCY – XL 1400 Dimensional DataModel A B C D E F G H J K L M N P BAYCURB0

TCY024G 561/2 36 293/16 189/16 111/16 69/16 613/16 17 21 253/8 171/2 10 3 47/16 30A, 38ATCY030G 561/2 36 293/16 189/16 111/16 69/16 613/16 17 21 243/8 171/2 10 3 47/16 30A, 38ATCY036G 64 36 291/16 189/16 111/16 69/16 111/8 17 191/4 271/2 171/2 10 3 83/4 30A, 38A, 33ATCY042G 64 36 291/16 189/16 111/16 69/16 111/8 17 191/4 271/2 171/2 10 3 83/4 30A, 38A, 33ATCY048G 651/4 45 333/8 211/16 151/16 415/16 91/8 2115/16 251/4 281/2 20 14 31/2 85/16 30A, 38A, 34ATCY060G 651/4 45 333/8 211/16 151/16 415/16 91/8 2115/16 251/4 281/2 20 14 31/2 85/16 30A, 38A, 34A

Table PC-15-B — TCX – XL 1200 Dimensional DataModel A B C D E F G H J K L M N P BAYCURB0

TCX024G 561/2 36 253/16 189/16 111/16 69/16 613/16 17 21 241/4 171/2 10 3 47/16 30A, 38ATCX030G 561/2 36 293/16 189/16 111/16 69/16 613/16 17 21 247/8 171/2 10 3 47/16 30A, 38ATCX036G 561/2 36 293/16 189/16 111/16 69/16 613/16 17 201/2 251/4 171/2 10 3 47/16 30A, 38ATCX042G 561/2 36 293/16 189/16 111/16 69/16 613/16 17 201/2 257/8 171/2 10 3 47/16 30A, 38ATCX048G 651/4 45 333/8 211/16 151/16 415/16 91/8 2115/16 253/8 301/4 20 14 31/2 85/16 30A, 38A,34ATCX060G 651/4 45 333/8 211/16 151/16 415/16 91/8 2115/16 253/16 287/8 20 14 31/2 85/16 30A, 38A,34A

Table PC-15-C — TCP – XE 1200 Dimensional DataModel A B C D E F G H J K L M N P BAYCURB0

TCP024F 561/2 36 253/16 189/16 111/16 69/16 613/16 17 21 241/4 171/2 10 3 47/16 30A, 38ATCP030F 561/2 36 293/16 189/16 111/16 69/16 613/16 17 21 247/8 171/2 10 3 47/16 30A, 38ATCP036F 561/2 36 293/16 189/16 111/16 69/16 613/16 17 201/2 251/4 171/2 10 3 47/16 30A, 38ATCP042F 561/2 36 293/16 189/16 111/16 69/16 613/16 17 201/2 257/8 171/2 10 3 47/16 30A, 38ATCP048F 651/4 45 333/8 211/16 151/16 415/16 91/8 2115/16 253/8 301/4 20 14 31/2 85/16 30A, 38A,34ATCP060F 651/4 45 333/8 211/16 151/16 415/16 91/8 2115/16 253/16 287/8 20 14 31/2 85/16 30A, 38A,34A

Table PC-15-D — TCC – XE 1000 Dimensional Data - Limited Availability 3 Phase Only, 2006Model A B C D E F G H J K L M N P BAYCURB0

TCC018F 551/4 36 253/16 189/16 111/16 69/16 613/16 17 215/16 251/2 171/2 10 3 47/16 30A, 38ATCC024F 551/4 36 253/16 189/16 111/16 69/16 613/16 17 215/16 251/2 171/2 10 3 47/16 30A, 38ATCC030F 551/4 36 293/16 189/16 111/16 69/16 613/16 17 203/16 255/16 171/2 10 3 47/16 30A, 38ATCC036F 551/4 36 293/16 189/16 111/16 69/16 613/16 17 185/8 243/16 171/2 10 3 47/16 30A, 38ATCC042F 551/4 36 293/16 189/16 111/16 69/16 613/16 17 19 24 171/2 10 3 47/16 30A, 38ATCC048F 645/16 45 333/8 211/16 151/16 415/16 91/8 2115/16 245/8 281/2 20 14 31/2 85/16 30A, 38A, 34ATCC060F 645/16 45 333/8 211/16 151/16 415/16 91/8 2115/16 245/8 281/2 20 14 31/2 85/16 30A, 38A, 34A

Page 135: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PC-16Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

PHAS

ED O

UT

PHAS

ED O

UT

Package Cooling1½ through 5 Tons

TCY-G TCX-G TCP-F TCC-FTable PC-16-A — Features 2-5 Ton 2-5 Ton 2-5 Ton 11/2-5 Ton• Impack Plus™ feature set .............................................................................................................. ✔ ✔ ✔ ✔• Climatuff® Compressor (1) .............................................................................................................. ✔ ✔ ✔ ✔• Comfort-RTM mode option ............................................................................................................... ✔ — — —• Coil Sav’RTM coil guard ................................................................................................................... ✔ ✔ — —• Direct drive two-speed fan motor ..................................................................................................... ✔ — — —• GE ECM variable speed fan motor .................................................................................................. ✔ — — —• Heavy vinyl - coated coil guard ........................................................................................................ — — ✔ —• Horizontal convertible to downflow .................................................................................................. ✔ ✔ ✔ ✔• Plate Fin coil .................................................................................................................................... ✔ ✔ ✔ ✔• Polarized plugs ................................................................................................................................ ✔ ✔ ✔ ✔• Powder paint .................................................................................................................................... ✔ ✔ ✔ ✔• 5-year limited compressor only warranty (Commercial use) ............................................................ ✔ ✔ ✔ ✔• 5-year limited compressor, coil and parts warranty (Residential use) ............................................. — — ✔ ✔• 5-year limited parts warranty (Residential use) ............................................................................... ✔ ✔ — —• 1-year limited coil and parts warranty (Commercial use) ................................................................ ✔ ✔ ✔ ✔• 10-year limited compressor and outdoor coil warranty (Residential use) ........................................ ✔ ✔ — —

Table PC-16-B — Comfort ControlsAY28X092 ............... Heat/Cool (Horizontal) ....................................................................................... ✔ ✔ ✔BAY28X1821 .......... 1-Stage Heating/Cooling .................................................................................... ✔ ✔ ✔BAY28X1831 .......... 2-Stage Heating/Cooling .................................................................................... ✔ ✔ ✔BAY28X1842 .......... Subbase Auto/Manual Changeover ................................................................... ✔ ✔ ✔BAY28X1853 .......... Subbase Manual Changeover ........................................................................... ✔ ✔ ✔BAY28X1872 .......... Subbase Auto Changeover ................................................................................ ✔ ✔ ✔BAY28X190 ............. Locking Thermostat Cover ................................................................................. ✔ ✔ ✔BAYSTAT0102 ........ Auto 2-Stage Heating/2 Cooling with Economizer ............................................. ✔ ✔ ✔BAYSTAT0082 ........ Manual 1-Stage Heating/1 Cooling .................................................................... ✔ ✔ ✔BAYSTAT0122 ........ Manual 1-Stage Heating/2 Cooling w/economizer ............................................. ✔ ✔ ✔BAYSTAT033A ........ Outdoor Thermostat ........................................................................................... ✔ ✔ ✔BAYSTAT253A ........ Humidity Control ................................................................................................ — — —BAYSTAT304 ........... Cooling Only with Fan Switch ............................................................................ ✔ ✔ ✔BAYSTAT305 ........... Heat/Cool Vertical .............................................................................................. ✔ ✔ ✔TAYSENS100A ........ Outdoor Temp. Sensor (with case)4 .................................................................. ✔ ✔ ✔TAYSTAT300C ......... XT 300C Prog.,7 Day,A/M 1Htg/1Clg ................................................................ ✔ ✔ ✔TAYSTAT302C ......... XT 302C Prog.,7 Day,A/M 2Htg/2Clg ................................................................ ✔ ✔ ✔TAYSTAT340 ........... Prog., 5/2 Day, Manual Thermostat ................................................................... ✔ ✔ ✔TAYSTAT3713 ......... Electronic 1Htg(Elec)/1Clg (Non Prog) .............................................................. ✔ ✔ ✔TCONT200 .............. 1Heat/1Clg (Gas, Oil or Electric) ....................................................................... ✔ ✔ ✔TCONT401 .............. 2Heat/1Clg (Heat Pump/A/C) ............................................................................ ✔ ✔ ✔TCONT402 .............. 3Heat/2Clg (Heat Pump/A/C) ............................................................................ ✔ ✔ ✔TCONT600 .............. 1Heat/1Clg (Heat Pump/A/C) ............................................................................ ✔ ✔ ✔TCONT602 .............. 2Heat/2Clg (Heat Pump/A/C) ............................................................................ ✔ ✔ ✔

TCONT800 .............. 1Heat/1Clg (Gas, Oil or Electric) ....................................................................... ✔ ✔ ✔

1 Requires Subbase.2 Requires BAY24X042 relay kit when used with electric heat.3 Specifically designed for electric heat applications (instant on fan).4 Used with TAYSTAT300C, TAYSTAT302C.

See

Com

fort

Con

trol

s/ Z

one

Sen

sors

Sec

tion

For information on Roof Curbs and Roof Curb Adaptors,please refer to the Accessories/Information Tab.

Page 136: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PC-17 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Package CoolingConvertible 1½ through 5 Tons

Table PC-17-A — Supplementary Heaters – Single Point Entry Kit/Heater MatrixUsed With Single Used With

Model No. Description Power Entry Kit1 Packaged Cooling Unit

BAYHTRN105A ..... 3.74/4.98 kW Heater (208/240V 1PH) .......... BAYSPEK047A ....... TCC018-042F1, TCP024-042F1,TCY/TCX024-42G1BAYHTRN108A ..... 5.76/7.68 kW Heater (208/240V 1PH) .......... BAYSPEK047A ....... TCC018-042F1, TCP024-042F1, TCY/TCX024-42G1BAYHTRN110A ..... 7.47/9.96 kW Heater (208/240V 1PH) .......... BAYSPEK047A ....... TCC/TCP024-048F1, TCY/TCX024-60G1

BAYSPEK053A ....... TCC/TCP060F1,TCY/TCX060G1BAYHTRN112A ..... 8.65/11.52 kW Heater (208/240V 1PH) ........ BAYSPEK049A ....... TCC/TCP024-048F1, TCY/TCX024-48G1

BAYSPEK053A ....... TCC/TCP060F1,TCY/TCX060G1BAYHTRN115A ..... 11.21/14.94 kW Heater (208/240V 1PH) ...... BAYSPEK048A ....... TCC/TCP030-048F1, TCY/TCX030-048G1

BAYSPEK052A ....... TCC/TCP060F1,TCY/TCX060G1BAYHTRN117A ..... 12.98/17.28 kW Heater (208/240V 1PH) ...... BAYSPEK048A ....... TCC/TCP030-048F1, TCY/TCX030-060G1

BAYSPEK052A ....... TCC/TCP060F1,TCY/TCX060G1BAYHTRN123A ..... 17.2/23.04 kW Heater (208/240V 1PH) ........ BAYSPEK048A ....... TCC/TCP030-48F1,TCY/TCX048G1

BAYSPEK052A ....... TCC/TCP060F1,TCY/TCX060G1BAYHTRN306A ..... 4.89/6.25 kW Heater (208/240V 3PH) .......... BAYSPEK047A ....... TCC//TCP036-060F3,TCX036-060G3BAYHTRN310A ..... 7.45/9.96 kW Heater (208/240V 3PH) .......... BAYSPEK047A ....... TCC/TCP036-060F3,TCX036-060G3BAYHTRN315A ..... 11.25/14.90 kW Heater (208/240V 3PH) ...... BAYSPEK047A ....... TCC/TCP036-060F3,TCX036-060G3BAYHTRN320A ..... 14.96/19.92 kW Heater (208/240V 3PH) ...... BAYSPEK051A ....... TCC/TCP042-060F3/TCX042-060G3BAYHTRN330A ..... 22.41/29.80 kW Heater (208/240V 3PH) ...... BAYSPEK050A ....... TCC/TCP060F3,TCX060G3BAYHTRN406A ..... 6kW Heater (480V 3PH) ............................. BAYSPEK047A ....... TCC/TCP036-060F4,TCX036-060G4BAYHTRN410A ..... 9.96 kW Heater (480V 3PH) ....................... BAYSPEK047A ....... TCC/TCP036-060F4,TCX036-060G4BAYHTRN410F ..... 9.96 kW Heater (480V 3PH) ....................... BAYSPEK047A ....... TCC/TCP036-060F4,TCX036-060G4BAYHTRN415A ..... 14.90 kW Heater (480V 3PH) ..................... BAYSPEK047A ....... TCC/TCP036-060F4,TCX036-060G4BAYHTRN420A ..... 19.92 kW Heater (480V 3PH) ..................... BAYSPEK047A ....... TCC/TCP048-060F4,TCX036-060G4BAYHTRN430A ..... 29.80 kW Heater (480V 3PH) ..................... BAYSPEK047A ....... TCC/TCP060F4,TCX060G4

1 All necessary fuses are included in kit

For information on Roof Curbs and Roof Curb Adaptors,please refer to the Accessories/Information Tab.

Page 137: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PC-18Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

PH

AS

ED

OU

T

Package CoolingConvertible 1½ through 5 Tons

TCY-G TCX-G TCP-F TCC-FTable PC-18-A — Accessories 2-5 2-5 2-5 1½-5BAY24X045 ........... DPDT Relay .................................................................................................... — — — 1½-5BAYASCT001 ........ Anti-Short Cycle Timer69 .............................................................................. 2-5 2-5 2-5 1½-5BAYCCHT003A ..... Crankcase Heater, 230V7 .............................................................................. 2-4 2-5 2-5 1½-5BAYCCHT202A ..... Crankcase Heater (230v) ................................................................................ 5 2½-5 2½-5 —BAYCCHT400A ..... Crankcase Heater (460v) ................................................................................. 3-5 3-5 3-5 —BAYCURB030A ..... Roof Curb (Flat Roof)2 (14 H x 34 W x 53 1/8 L) ............................................ 2-5 2-5 2-5 1½-5BAYCURB033A ..... Roof Curb (Flat Roof)2 Acousti-Curb (14 H x 34 W x 60 5/8 L) ...................... 3-3½ — — —BAYCURB034A ..... Roof Curb (Flat Roof)2 Acousti-Curb (14 H x 43 W x 62 1/16 L) .................... 4-5 4-5 4-5 4-5BAYCURB038A ..... Roof Curb (Flat Roof)2 Acousti-Curb (14 H x 34 W x 53 1/8 L) ...................... 2-5 2-5 2-5 1½-5BAYDMPR040A ..... 0-25% Manual Fresh Air Damper14 .............................................................. 2-3½ 2-3½ 2-3½ 1½-3½BAYDMPR041A ..... 0-25% Manual Fresh Air Damper14 .............................................................. 4-5 4-5 4-5 4-5BAYDMPR050A ..... Motorized Fresh Air Damper1 ....................................................................... 4-5 4-5 4-5 4-5BAYDUCT004A ..... 12" Round Duct Adapters (2 per Box) ............................................................. 2-3½ 2-3½ 2-3½ 1½-3½BAYDUCT005A ..... 14" Round Duct Adapters (1 per Box) ............................................................. 2-3½ 2-3½ 2-3½ 1½-3½BAYECMT002A ..... Extreme Conditions Mounting Kit (Curb Mount) ............................................... 2-5 2-5 2-5 1½-5BAYECMT003A ..... Extreme Conditions Mounting Kit (Slab or Rack Mount) ................................. 2-5 2-5 2-5 1½-5BAYECON054B ..... 0-100% Mod. Economizer with Bar Relief1345 ............................................ 2-3½ 2-3½ 2-3½ 1½-3½BAYECON055B ..... 0-100% Mod. Economizer with Bar Relief1345 ............................................ 4-5 4-5 4-5 4-5BAYECON073A ..... 0-100% Mod. Economizer – Horizontal135 ................................................... 2-5 2-5 2-5 1½-5BAYENTH001A ..... Enthalpy Control (Solid State)3 ...................................................................... 2-5 2-5 2-5 1½-5BAYFLTR012A ....... Filter Frame1 (20 x 25 x 1" filter not included) ................................................ 2-2½ 2-3½ 2½-3½ 2½-3½BAYFLTR013A ....... Filter Frame1 (20 x 25 x 1" filter not included) ................................................ 3-3½ — — —BAYFLTR014A ....... Filter Frame1 (3-10 x 25 x 1" filter not included) ............................................. 4-5 4-5 4-5 4-5BAYFLTR015A ....... Filter Frame1 (20 x 20 x 1" filter not included) ................................................ — 2-5 2 1½-2BAYFLTR017A ....... Filter Frame1 (1-20 x 25 x 2" filter not included) ............................................. 2-2½ 2-3½ 2½-3½ 2½-3½BAYFLTR018A ....... Filter Frame1 (1-20 x 25 x 2" filter not included) ............................................. 3-3½ — — —BAYFLTR019A ....... Filter Frame1 (2-16 x 25 x 2" filter not included) ............................................. 4-5 4-5 4-5 4-5BAYGARD016A ..... Condenser Coil Guard ..................................................................................... — — — 1½-2BAYGARD017A ..... Condenser Coil Guard ..................................................................................... — — — 31/2BAYGARD018A ..... Condenser Coil Guard ..................................................................................... — — — 2½-3BAYGARD021A ..... Condenser Coil Guard ..................................................................................... — — — 4-5BAYHSMT043A ..... High Static Motor (230/460V) 3/4HP ................................................................ — 2½-3½ 2½-3½ 2½-3½BAYHSMT044A ..... High Static Motor (230/460V) 1HP ................................................................... — 4 4-5 4-5BAYHSMT045A ..... High Static Motor (208V) 1HP ......................................................................... — 4 4-5 4-5BAYHSMT056A ..... High Static Motor (208V) 3/4HP ...................................................................... — 2½-3½ 2½-3½ 2½-3½BAYINDK001A* ..... Insulated Deck Pan for A & B Cabinet ............................................................. 2-5 2-5 2-5 1½-5BAYINDK002A** .... Insulated Deck Pan for C Cabinet .................................................................... 2-3½ — — —BAYINDK003A*** ... Insulated Deck Pan for D Cabinet .................................................................... 4-5 4-5 4-5 4-5BAYKSKT010A ...... Quick Start Kit (Single Phase Models Only) .................................................... — — — 1½-5BAYKSKT254 ........ Start Kit - Scroll Models Only(Single Phase Models Only) ............................... — 2½-4 2½-4 —BAYLIFT002B ........ Lifting Lug Kit .................................................................................................. 2-5 2-5 2-5 1½-5BAYLOAM011A ..... Evaporator Defrost Control Kit ......................................................................... 2-5 2-5 2-5 1½-5BAYLOAM323A ..... Dual Voltage Elec. Head Pressure Control (208-230V or 460V)78 .................... 2-5 2-5 2-5 1½-5BAYMOTR307A ..... 200-230V 1/2HP Ball Bearing OD Motor (use with BAYLOAM323A) .................. 2-3½ 2-5 2-5 1½-5BAYMOTR406A ..... 460V 1/2HP Ball Bearing OD Motor (use with BAYLOAM323A) ......................... — 3-5 3-5 1½-5BAYRLAY002 ......... Time Delay Relay ............................................................................................ 2-5 2-5 2-5 —BAYSTAT023 ......... Remote Potentiometer for BAYECON054B, 055B, 073A ................................. 2-5 2-5 2-5 1½-5BAYUTIL030A ....... Roof Curb Utility Extension Kit for BAYCURB030A, 038A ................................ — — — 1½-5BAYUTIL033A ....... Roof Curb Utility Extension Kit for BAYCURB033A .......................................... — — — —BAYUTIL034A ....... Roof Curb Utility Extension Kit for BAYCURB034A .......................................... — — — 4-51 Must use filter frame when economizer/fresh air kit is used.2 Ships knocked down.3 Dry bulb control standard with economizer.4 Downflow Only.5 2-Stage thermostat provides additional energy savings if

simultaneous economizer and compressor operation is expected.6 Do not use with programmable thermostats.

7 Low ambient cooling requires crankcase heater.8 May require motor change. (See Installers Guide.)9 Activated on Power On.* Currently Shipped with BAYCURB038A.** Currently Shipped with BAYCURB033A.***Currently Shipped with BAYCURB034A.

For information on Roof Curbs and Roof Curb Adaptors,please refer to the Accessories/Information Tab.

Page 138: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PC-19 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Table PC-19-A — XE 1200 — Cooling - Single Phase (208/230/1/60)Cooling Round Round Shipping

Unit Capacity Dimensions (in.) Supply Return Weight SoundTons Model No. SEER/EER* (Btuh) H x W x L Opening Opening (Ibs.) Rating Compressor

2 TCK024A100B 12.00/10.49 24,000 31 x 32 x 44 (**) 14" 14" 334 73 R121/2 TCK030A100B 12.00/10.62 30,000 31 x 32 x 44 (**) 14" 14" 341 73 S3 TCK036A100B 12.00/10.63 36,000 31 x 32 x 44 (**) 14" 14" 343 73 S31/2 TCK042A100B 12.00/10.45 41,000 31 x 32 x 44 (**) 14" 14" 351 73 S31/2 TCK042A1H0B 12.00/10.45 41,000 31 x 32 x 44 (**) 14" 14" 351 73 S4 TCK048A100B 11.80/10.33 45,000 31 x 32 x 44 (**) 14" 14" 372 73 S

TCK

• Climatuff® compressor• Compressor motor overload protection• Internal pressure relief valve• Copper tube, aluminum plate fin coils• Shaft-Down OD fan system for quiet

operation (good neighbor)• Sloped composite drain pan• Waterproof closed-cell foam evaporator

base insulation

Package Cooling/Electric Heat2 through 4 Tons

• Heavy gauge steel cabinet• Weather resistant Powder Paint• Double powder painted G90 base pan with

dimpled feet• Wrap-around vinyl-coated wire coil guards• U.L. listed• 5-year limited warranty on compressor and

5-year on all other parts (Residential use)• Optional extended warranties

Table PC-19-B — Electric Heater DataUsing Single Supply Circuit

TCK Cooling/HTG Heater Only Supply CircuitMax Fuse Canada Only Max Fuse Canada Only

Unit Electric Rated Heater kW or HACR CKT Max. CKT or HACR CKT Max. CKTModel No. Heater Model Voltage 208/240 MCA22222 BKR Size44444 BKR Size55555 MCA66666 BKR Size44444 BKR Size55555

TCK024A1 BAYHTRK105A 208/240 3.74/4.98 25/2933333 25/30 30/30 23/26 25/30 30/30BAYHTRK110A 208/240 7.48/9.96 47/5533333 50/60 50/60 45/52 45/60 50/60

TCK030A1 BAYHTRK105A 208/240 3.74/4.98 25/2933333 25/30 30/30 23/26 25/30 30/30BAYHTRK110A 208/240 7.48/9.96 48/5533333 50/60 50/60 45/52 45/60 50/60

TCK036A1 BAYHTRK105A 208/240 3.74/4.98 25/2933333 25/30 30/30 23/26 25/30 30/30BAYHTRK110A 208/240 7.48/9.96 48/5533333 50/60 50/60 45/52 45/60 50/60

TCK042A1 BAYHTRK105A 208/240 3.74/4.98 27/3033333 30/30 30/30 23/26 25/30 30/30BAYHTRK110A 208/240 7.48/9.96 49/5633333 50/60 50/60 45/52 45/60 50/60BAYHTRK115A 208/240 11.22/14.94 71/8133333 80/90 100/100 68/78 70/80 70/100

TCK048A166666 BAYHTRK106A 208/240 3.74/4.98 26/3033333 30/30 30/30 23/26 25/30 30/30BAYHTRK110A 208/240 7.48/9.96 50/6033333 50/60 50/60 45/52 45/60 50/60BAYHTRK115A 208/240 11.22/14.94 71/8133333 80/90 100/100 68/78 70/80 70/100

NOTES:1 Any power supply and circuits must be wired and protected in accordance with local electrical codes.2 The MCA values listed are for electric heater and cooling unit.3 Field wire must be rated at least 75°C.4 The HACR circuit breaker is for U.S.A. installations only.5 For Canada installation reference only6 BAYHTRK106A only approved for TCK048A17 The MCA values listed are for electric heater only.8 The MCA values listed are for electric heater and heat pump.

TCK-A models will be upgraded in the 1st Quarter of 2006.

For information on Roof Curbs and Roof Curb Adaptors,please refer to the Accessories/Information Tab.

Page 139: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PC-20Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

1 Requires subbase.2 Requires BAY24X042 relay when used with electric heaters.3 Specially designed for electric heater application (instant on fan).4 Not for use with programmable thermostats.A/M = Automatic or Manual Changeover* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.

Table PC-20-A — Accessories/Comfort ControlsModel No. Description Used With

AY28X092 Heat/Cool (Horizontal) Therm. All Cooling ModelsBAY28X1821 1-Stage Heating/Cooling Therm. All Cooling ModelsBAY28X1831 2-Stage Heating/Cooling Therm. All Cooling ModelsBAY28X1842 Subbase Auto/Man. Changeover BAY28X183BAY28X1853 Subbase Man. Changeover BAY28X182,183BAY28X1872 Subbase Auto Changeover BAY28X182,183BAY28X1904 Locking Thermostat Cover All Room ThermostatsBAYCOVR100A Wallcover Plate TAYSTAT371BAYECMT002A Extreme Conditions Mounting Kit (Curb Mount) All TCK ModelsBAYECMT003A Extreme Conditions Mounting Kit (Slab and Rack Mount) All TCK ModelsBAYSTAT304 Cooling only with Fan Switch All Cooling ModelsBAYSTAT305 Heat/Cool Vertical All Cooling ModelsTAYSENS100A Outdoor Temperature Sensor (with case) TAYSTAT300TAYSTAT300C XT300C Prog.,7 Day,A/M,1Htg./Clg. All Cooling ModelsTAYSTAT340 Prog.,5/2 Day,Manual,1 Htg./Clg. All Cooling ModelsTAYSTAT3713 Electronic,1Htg(Elec)/1Clg (Non Prog) All Cooling ModelsTCONT200A 1Heat/1Clg (Gas, Oil or Electric) All Cooling ModelsTCONT401A 2Heat/1Clg (Heat Pump/A/C) All Cooling ModelsTCONT402A 3Heat/2Clg (Heat Pump/A/C) All Cooling ModelsTCONT600A 1Heat/1Clg (Heat Pump/A/C) All Cooling Models

Package Cooling/Electric Heat2 through 4 Tons

TCK-A models will be upgraded in the 1st Quarter of 2006.

For information on Roof Curbs and Roof Curb Adaptors,please refer to the Accessories/Information Tab.

Page 140: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PC-21 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

PHASED OUT

PHASED OUT

PHASED OUT

PHASED OUT

TCM

• Climatuff® compressor• High efficiency performance• Round duct connections for Manufactured

Housing• Quiet operating top condenser

air discharge• Copper tube/aluminum fin coils• Totally enclosed, permanently lubricated

condenser fan motor• Hermetically sealed compressor

with internal relief valve• Two-Speed evaporator blower motor

• Sloped Drain Pan• Fully charged R-22 system• Heavy gauge steel cabinet with weather

resistant, baked enamel finish• Protected pressure taps for

refrigerant checks• Fully insulated air handling compartment• Convenient access panels• 5-year limited compressor warranty

(Residential use)• 5-year limited coil and parts warranty

(Residential use)

Package Cooling – ManufacturedHousing 2½ through 4 Tons

Table PC-21-A — TCM (208-230/1/60)Cooling Cabinet Round Round Shipping

Unit Capacity Dimensions (in.) Supply Return Weight Max SoundModel No. SEER/EER* (Btuh) H x W x L Opening Opening (Ibs.) MCA* Fuse* Rating Compressor

TCM030F100B 9.7/9.10 29,800 29 x 36 x 55 (B) 12 12 358 22.7 35 80 R1TCM036F100B 9.7/8.75 35,200 29 x 36 x 55 (B) 12 12 380 26.8 45 80 R1TCM042F100B 9.7/8.60 40,500 29 x 36 x 55 (B) 14 14 383 31.8 50 80 R2TCM048F100B 9.7/8.90 46,500 29 x 36 x 63 (C) 14 14 461 33.0 50 82 R2

Table PC-21-B — Supplementary Heaters – Heater MatrixModel No. Description Used With

BAYHTRN105A 3.74/4.98 kW Heater (208/240 volt) TCM030, 036, 042FBAYHTRN108A 5.76/7.68 kW Heater (208/240 volt) TCM030, 036, 042FBAYHTRN110A 7.47/9.96 kW Heater (208/240 volt) TCM030, 036, 042, 048FBAYHTRN112A 8.65/11.52 kW Heater (208/240 volt) TCM030, 036, 042FBAYHTRN115A 11.21/14.94 kW Heater (208/240 volt) TCM030, 036, 042FBAYHTRN117A 12.98/17.28kW Heater (208/240 volt) TCM030, 036, 042, 048F

Table PC-21-C — AccessoriesModel No. Description Used With

BAYCCHT003A Crankcase Heater (230 volt) All TCM-F ModelsBAYECMT002A Extreme Conditions Mounting Kit (Curb Mount) All TCM ModelsBAYECMT003A Extreme Conditions Mounting Kit (Slab and Rack Mount) All TCM ModelsBAYFLTR012A Filter Frame (20x25x1" filer not included) TCM030, 036, 042FBAYFLTR013A Filter Frame (20x25x1" filer not included) TCM042FBAYGARD017A Condenser Coil Guard TCM042, 048FBAYGARD018A Condenser Coil Guard TCM030, 036FBAYHSMT043A High Static Motor All TCM-F ModelsBAYHSMT044A High Static Motor All TCM-F ModelsBAYHSMT045A High Static Motor All TCM-F ModelsBAYHSMT056A High Static Motor All TCM-F ModelsBAYKSKT010A Quick Start Kit All TCM-F Models

Table PC-21-D — Comfort ControlsModel No. Description Used With

AY28X092 Heat/Cool Horizontal All TCM-F ModelsBAYSTAT304 Cooling Only with Fan Switch All TCM-F ModelsBAYSTAT305 Heat/Cool Vertical All TCM-F ModelsBAYSTAT033A Outdoor Thermostat All TCM-F ModelsTCONT200A 1Heat/1Clg All TCM-F ModelsTCONT401A 2Heat/1Clg All TCM-F ModelsTCONT402A 3Heat/2Clg All TCM-F ModelsTCONT600A 1Heat/1Clg All TCM-F Models

* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.Compressor Types are: R1 = Reciprocating One Cylinder, R2 = Reciprocating Two Cylinder, S = Scroll

For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.

Page 141: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PC-22Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

• Climatuff® compressor• Compressor motor

overload protection• Internal pressure relief

valve• Copper tube, aluminum

plate fin coils• Pressure taps for

refrigerant check• Top discharge condens-

ing fan• Indoor fan relay• Top access to supple-

mentary heater• Polarized plug for easy

field connection of lowvoltage to supplementaryheaters

• Over (supply) under(return) airconfiguration

• Wrap around coil guard• Expansion valve on

indoor coil• Heavy gauge steel

cabinet• Multi-speed direct drive

blower Variable speeddirect drive blower motorton TCH-048-060F models

• Factory installed coilguard

• Low ambient cooling to45° F as manufactured

• UL listed• 5 year limited warranty

on compressor and 5year on all other parts(residential use only)

• Optional extendedwarranties

• Energy Star Listed

TCH

Package CoolingOver/Under 2 through 5 Tons

LEFT SIDE

311mm[12-1/4]

Top Diagram Only

Table PC-22-A — TCH – Over/Under Horizontal UnitPower Supply Nom. Cap. Shipping

Unit Volts Cooling Dimensions (in.) Weight Max SoundModel No. Phase/Hz SEER/EER* (Btuh) H x W x L (Ibs.) MCA* Fuse* Rating Comp.

Single PhaseTCH024B100B 208-230/1/60 12.05/11.00 24,000 303/8 x 315/8 x 44 319 17.2 25 79 R1TCH030B100B 208-230/1/60 12.6/11.00 30,000 303/8 x 315/8 x 44 335 19.3 30 82 R2TCH036B100C 208-230/1/60 12.0/11.30 36,000 303/8 x 315/8 x 44 370 25.5 40 82 R2TCH042B100B 208-230/1/60 12.5/11.00 41,500 303/8 x 315/8 x 44 374 24.1 40 82 R2

TCH048F100A 208-230/1/60 13.75/12.35 50,000 33 x 45 x 58 504 37 50 84 S

TCH060F100A 208-230/1/60 13.00/11.45 62,000 33 x 45 x 58 509 47 60 84 S

Tons Supply H x W Return H x W

2 – 31/2 83/8 x 273/8 163/4 x 273/8

4 – 5 81/2 x321/32 1915/16 x 321/32

Table PC-22-B — TCH – Over/Under Horizontal UnitPower Supply Nom. Cap. Dimensions Shipping

Unit Volts Performance Cooling (in.) Weight Max SoundTons Model No. Phase/Hz SEER (Btuh) H x W x L (Ibs.) MCA* Fuse* Rating

Three Phase

3 TCH036B300C 208-230/3/60 11.4 36,000 303/8 x 315/8 x 44 370 17.8 25 8231/2 TCH042B300B 208-230/3/60 12.5 41,500 303/8 x 315/8 x 44 374 18.1 25 82

3 TCH036B400C 460/3/60 11.4 36,000 303/8 x 315/8 x 44 370 9.7 15 8231/2 TCH042B400B 460/3/60 12.5 41,500 303/8 x 315/8 x 44 374 9.9 15 82

Tons Supply H x W Return H x W

3 – 31/2 83/8 x 273/8 163/4 x 273/8Dimensions are in inches. See Outline Dimensions.* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.

TCH-B models will be upgraded inthe 1st Quarter of 2006.

For information on Roof Curbs andRoof Curb Adaptors, please refer tothe Accessories/Information Tab.

Page 142: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PC-23 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

RIGHT SIDE

422mm[16-5/8]

Package CoolingOver/Under 2 through 5 Tons

Table PC-23-A — Supplementary Heaters – Heater MatrixModel No. Power Supply kW Rating Used With

BAYHTRC106A 208/240/1/60 4.33/5.76 kW TCH024-042B100A, 048F, 060F100ABAYHTRC108A 208/240/1/60 6.12/8.16 kW TCH024-042B100ABAYHTRC110A 208/240/1/60 7.93/10.56 kW TCH048F1 onlyBAYHTRC111A 208/240/1/60 7.93/10.56 kW TCH024-042B100A, 060F1BAYHTRC112A 208/240/1/60 8.65/11.52 kW TCH024-042B100ABAYHTRC117A1 208/240/1/60 12.98/17.28kW TCH030-042B100A, 048F, 060F1BAYHTRC306A 208/240/3/60 4.33/5.76 TCH036-042B300ABAYHTRC312A 208/240/3/60 8.65/11.52 TCH036-042B300ABAYHTRC317A 208/240/3/60 12.98/17.28 TCH036-042B300ABAYHTRC406A 480/3/60 5.76 TCH036-042B400ABAYHTRC412A 480/3/60 11.52 TCH036-042B400ABAYHTRC417A 480/3/60 17.28 TCH036-042B400A

Table PC-23-B — Accessories/Comfort ControlsModel No. Description Used With

AY28X092 ............................. Heat/Cool (Horizontal) Thermostat .......................................... All Cooling ModelsBAY24X042 .......................... DPDT Fan and Electric Heat Relay ......................................... Auto Changeover T-StatBAY28X1822 ...................... 1-Stage Heating/Cooling Thermostat ...................................... All Cooling ModelsBAY28X1843 ...................... Subbase Automatic/Manual Changeover ................................ BAY28X182BAY28X1854 ...................... Subbase Manual Changeover ................................................. BAY28X182BAY28X1873 ...................... Subbase Automatic Changeover ............................................. BAY28X182BAY28X190 ......................... Locking Thermostat Cover ...................................................... All Room ThermostatsBAY41X171A ........................ 5 or 7 Minute Delay Relay ....................................................... All TCH ModelsBAYASCT00156 ................. Anti-Short Cycle Timer ............................................................ All TCH ModelsBAYECMT002A .................... Extreme Conditions Mounting Kit (Curb Mount) ...................... All TCH ModelsBAYECMT003A .................... Extreme Conditions Mounting Kit (Slab and Rack Mount) ...... All TCH ModelsBAYLOAM011A .................... Low Ambient Cooling Kit ......................................................... All TCH ModelsBAYSTAT304 ........................ Cooling Only with Fan Switch .................................................. All Cooling ModelsBAYSTAT305 ........................ Heat/Cool Vertical ................................................................... All Cooling ModelsTAYASCT501A56 ................ Anti-Short Cycle Timer ............................................................ All Cooling ModelsTAYSENS100A ..................... Outdoor Temp. Sensor (with case) .......................................... TAYSTAT300C,302CTAYSTAT300C ....................... XT300C Prog.,7 Day,A/M,1Htg/1Clg ....................................... All Cooling ModelsTCONT200A ......................... 1Heat/1Clg (Gas, Oil or Electric) ............................................. All Cooling ModelsTCONT401A ......................... 2Heat/1Clg (Heat Pump/A/C) .................................................. All Cooling ModelsTCONT402A ......................... 3Heat/2Clg (Heat Pump/A/C) .................................................. All Cooling ModelsTCONT600A ......................... 1Heat/1Clg (Heat Pump/A/C) .................................................. All Cooling Models

1 This model has a fuse box factory installed.2 Requires subbase.3 Requires BAY24X042 relay when used with electric heaters.4 Specially designed for electric heater application (instant on fan).5 Not for use with programmable thermostats.6 Activated on Power Off.

TCH-B models will be upgradedin the 1st quarter of 2006.

For information on Roof Curbs andRoof Curb Adaptors, please refer tothe Accessories/Information Tab.

Page 143: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PC-24Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Standard Features:• Trane built scroll compressors on all 3-10 ton units except 3 ton standard efficiency

model (Reciprocating Compressor)• Colored and numbered wiring• Provisions for through the Base Condensate Drain Connections• Patented Hybrid Condenser Coil for easy cleaning• 1" throwaway filters provided on 3-5 ton units• 2" throwaway filters provided on 6-10 ton units• Liquid Line Refrigerant Drier• Operating Charge of R-22 or R-410A• IAQ Sloped Drain Pans• Single point power for Electric Heat• Low Ambient to 40°F on Electromechanical models• Low Ambient to 0°F on Microprocessor models• 5 - year Limited Compressor Warranty• 1 - year Limited Parts Warranty

Added Flexibility

• Electromechanical or ReliaTel™ controls (See page PC-35 for ReliaTel™Control Information)

• Standard or high efficiency cooling models available• Convertible airflow (ships in downflow application)• Fork lift openings on three sides of unit• Direct or belt drive - standard or oversized motors (Direct for 3-5 ton only)• We don’t prepackage options• Choose options tailored to suit each job —pay only for what is needed• Units ship with options installed —and within our standard ship cycle time

Factory Installed Options

• Through-the-Base — Electrical• Convenience Outlet — Powered or unpowered• Unit Disconnect Switch• Smoke Detectors — Supply, return, or both• Condenser Coil Coating• Hinged Access Service Panels• Discharge Air Sensor• Fan Fail and Clogged Filter Switches• Condenser Coil Guard — Hail Protection Quality• TXV thermal expansion valve and split face evaporator coil• Dehumidification Hot Gas Reheat Coil• Novar Controls• TCI (Trane Communication Interface)• LonTalk (Communication Interface)• 2" Pleated Media filters• Phase Monitor

The same Trane Quality andReliability … with added Flexibility!

Precedent™ 3-10 tonPackaged Cooling

FeaturingA New Look for a New Century

Beveled TopSmoother DesignSmall compact cabinetRecessed access handles

Page 144: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PC-25 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Table PC-25-A — Base Unit — Standard Efficiency — ElectromechanicalCooling Cabinet Shipping

Unit Performance33333 Capacity Dimensions (in.) Downflow Downflow Weight Max2Tons Ordering No.44444 SEER/EER (Btuh) H x W x L Supply Return (Ibs.) MCA* Fuse*

TSC – 208-230/1/60 – Single Phase – No Heat3 TSC036E1E0A0000 13.0 35,620 32 x 44 x 70 18 x 15.5 24 x 14 555 27.2 404 TSC048E1E0A0000 13.0 49,210 32 x 44 x 70 18 x 15.5 24 x 14 586 35.2 505 TSC060E1E0A0000 13.0 58,000 32 x 44 x 70 18 x 15.5 24 x 14 636 43.8 70TSC – 208-230/3/60 – Three Phase – No Heat3 TSC036A3E0A0000 10.7 37,400 32 x 44 x 70 18 x 15.5 24 x 14 501 17.9 254 TSC048A3E0A0000 10.0 49,200 32 x 44 x 70 18 x 15.5 24 x 14 526 23.9 355 TSC060A3E0A0000 10.2 63,100 32 x 44 x 70 18 x 15.5 24 x 14 543 31.5 503 TSC036E3E0A0000 13.0 37,150 32 x 44 x 70 18 x 15.5 24 x 14 555 21.4 304 TSC048E3E0A0000 13.0 49,450 32 x 44 x 70 18 x 15.5 24 x 14 586 25.2 355 TSC060E3E0A0000 13.0 62,270 32 x 44 x 70 18 x 15.5 24 x 14 636 29.5 456 TSC072A3E0A0000 10.3 72,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 824 32.7 5071/2 TSC090A3E0A0000 10.3 90,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 897 42.7 6071/2 TSC092A3E0A0000 10.3 90,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 899 38.9 5081/2 TSC102A3E0A0000 10.3 105,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 978 45.1 6010 TSC120A3E0A0000 10.4/10.31 117,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1052 52.6 60TSC – 460/3/60 – Three Phase – No Heat3 TSC036A4E0A0000 10.7 37,400 32 x 44 x 70 18 x 15.5 24 x 14 501 9.2 154 TSC048A4E0A0000 10.0 49,200 32 x 44 x 70 18 x 15.5 24 x 14 526 12.8 205 TSC060A4E0A0000 10.2 63,100 32 x 44 x 70 18 x 15.5 24 x 14 543 16.0 253 TSC036E4E0A0000 13.0 37,150 32 x 44 x 70 18 x 15.5 24 x 14 555 10.1 154 TSC048E4E0A0000 13.0 49,450 32 x 44 x 70 18 x 15.5 24 x 14 586 12.5 155 TSC060E4E0A0000 13.0 62,270 32 x 44 x 70 18 x 15.5 24 x 14 636 15.5 256 TSC072A4E0A0000 10.3 72,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 824 17.6 2571/2 TSC090A4E0A0000 10.3 90,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 897 22.6 3571/2 TSC092A4E0A0000 10.3 90,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 899 20.5 2581/2 TSC102A4E0A0000 10.3 105,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 978 24.0 3010 TSC120A4E0A0000 10.4/10.31 117,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1052 26.9 35TSC – 575/3/60 – Three Phase – No Heat3 TSC036AWE0A0000 10.7 37,400 32 x 44 x 70 18 x 15.5 24 x 14 501 7.7 154 TSC048AWE0A0000 10.0 49,200 32 x 44 x 70 18 x 15.5 24 x 14 526 9.8 155 TSC060AWE0A0000 10.2 63,100 32 x 44 x 70 18 x 15.5 24 x 14 543 12.2 153 TSC036EWE0A0000 13.0 37,150 32 x 44 x 70 18 x 15.5 24 x 14 555 8.0 154 TSC048EWE0A0000 13.0 49,450 32 x 44 x 70 18 x 15.5 24 x 14 586 9.0 155 TSC060EWE0A0000 13.0 62,270 32 x 44 x 70 18 x 15.5 24 x 14 636 10.1 156 TSC072AWE0A0000 10.3 72,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 824 12.8 2071/2 TSC090AWE0A0000 10.3 90,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 897 17.6 2571/2 TSC092AWE0A0000 10.3 90,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 899 15.5 2081/2 TSC102AWE0A0000 10.3 105,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 978 19.5 2510 TSC120AWE0A0000 10.4/10.31 117,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1052 21.8 25

1 Upflow/Horizontal.2 HACR breaker per NEC.3 SEER applies, 3-5 tons; EER applies 6-10 tons.4 Digit 7-A=R-22 or E=410A* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.

Precedent™ Packaged CoolingConvertible 3-10 Tons

Page 145: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PC-26Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Precedent™ Packaged CoolingConvertible 3-10 Tons

Table PC-26-A — Base Unit — Standard Efficiency — ReliaTel™ Microprocessor ControlsCooling Cabinet Shipping

Unit Performance33333 Capacity Dimensions (in.) Downflow Downflow Weight Max2Tons Ordering No.44444 SEER/EER (Btuh) H x W x L Supply Return (Ibs.) MCA* Fuse*

TSC – 208-230/1/60 – Single Phase – No Heat3 TSC036E1R0A0000 13.0 35,620 32 x 44 x 70 18 x 15.5 24 x 14 555 27.2 404 TSC048E1R0A0000 13.0 49,210 32 x 44 x 70 18 x 15.5 24 x 14 586 35.2 505 TSC060E1R0A0000 13.0 58,000 32 x 44 x 70 18 x 15.5 24 x 14 636 43.8 70TSC – 208-230/3/60 – Three Phase – No Heat3 TSC036A3R0A0000 10.7 37,400 32 x 44 x 70 18 x 15.5 24 x 14 501 17.9 254 TSC048A3R0A0000 10.0 49,200 32 x 44 x 70 18 x 15.5 24 x 14 526 23.9 355 TSC060A3R0A0000 10.2 63,100 32 x 44 x 70 18 x 15.5 24 x 14 543 31.5 503 TSC036E3R0A0000 13.0 37,150 32 x 44 x 70 18 x 15.5 24 x 14 555 21.4 304 TSC048E3R0A0000 13.0 49,450 32 x 44 x 70 18 x 15.5 24 x 14 586 25.2 355 TSC060E3R0A0000 13.0 62,270 32 x 44 x 70 18 x 15.5 24 x 14 636 29.5 456 TSC072A3R0A0000 10.3 72,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 824 32.7 5071/2 TSC090A3R0A0000 10.3 90,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 897 42.7 6071/2 TSC092A3R0A0000 10.3 90,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 899 38.9 5081/2 TSC102A3R0A0000 10.3 105,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 978 45.1 6010 TSC120A3R0A0000 10.4/10.31 117,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1052 52.6 60TSC – 460/3/60 – Three Phase – No Heat3 TSC036A4R0A0000 10.7 37,400 32 x 44 x 70 18 x 15.5 24 x 14 501 9.2 154 TSC048A4R0A0000 10.0 49,200 32 x 44 x 70 18 x 15.5 24 x 14 526 12.8 205 TSC060A4R0A0000 10.2 63,100 32 x 44 x 70 18 x 15.5 24 x 14 543 16.0 253 TSC036E4R0A0000 13.0 37,150 32 x 44 x 70 18 x 15.5 24 x 14 555 10.1 154 TSC048E4R0A0000 13.0 49,450 32 x 44 x 70 18 x 15.5 24 x 14 586 12.5 155 TSC060E4R0A0000 13.0 62,270 32 x 44 x 70 18 x 15.5 24 x 14 636 15.5 256 TSC072A4R0A0000 10.3 72,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 824 17.6 2571/2 TSC090A4R0A0000 10.3 90,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 897 22.6 3571/2 TSC092A4R0A0000 10.3 90,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 899 20.5 2581/2 TSC102A4R0A0000 10.3 105,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 978 24.0 3010 TSC120A4R0A0000 10.4/10.31 117,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1052 26.9 35TSC – 575/3/60 – Three Phase – No Heat3 TSC036AWR0A0000 10.7 37,400 32 x 44 x 70 18 x 15.5 24 x 14 501 7.7 154 TSC048AWR0A0000 10.0 49,200 32 x 44 x 70 18 x 15.5 24 x 14 526 9.8 155 TSC060AWR0A0000 10.2 63,100 32 x 44 x 70 18 x 15.5 24 x 14 543 12.2 153 TSC036EWR0A0000 13.0 37,150 32 x 44 x 70 18 x 15.5 24 x 14 555 8.0 154 TSC048EWR0A0000 13.0 49,450 32 x 44 x 70 18 x 15.5 24 x 14 586 9.0 155 TSC060EWR0A0000 13.0 62,270 32 x 44 x 70 18 x 15.5 24 x 14 636 10.1 156 TSC072AWR0A0000 10.3 72,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 824 12.8 2071/2 TSC090AWR0A0000 10.3 90,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 897 17.6 2571/2 TSC092AWR0A0000 10.3 90,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 899 15.5 2081/2 TSC102AWR0A0000 10.3 105,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 978 19.5 2510 TSC120AWR0A0000 10.4/10.31 117,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1052 21.8 25

1 Upflow/Horizontal.2 HACR breaker per NEC.3 SEER applies, 3-5 tons; EER applies 6-10 tons.4 Digit 7-A=R-22 or E=410A* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.

Page 146: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PC-27 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Precedent™ Packaged CoolingConvertible 3-10 Tons

Table PC-27-A — Base Unit — High Efficiency — ElectromechanicalCooling Cabinet Shipping

Unit Performance33333 Capacity Dimensions (in.) Downflow Downflow Weight Max1Tons Ordering No. SEER/EER (Btuh) H x W x L Supply Return (Ibs.) MCA* Fuse*

THC – 208-230/3/60 – Three Phase – No Heat6 THC072A3E0A0000 11.5/11.32 72,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 861 34.8 5071/2 THC092A3E0A0000 11.5/11.32 90,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 899 38.1 5081/2 THC102A3E0A0000 11.5/11.32 102,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1036 42.3 5010 THC120A3E0A0000 11.2/10.72 116,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1125 48.6 60THC – 460/3/60 – Three Phase – No Heat6 THC072A4E0A0000 11.5/11.32 72,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 861 17.5 2571/2 THC092A4E0A0000 11.5/11.32 90,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 899 19.4 2581/2 THC102A4E0A0000 11.5/11.32 102,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1036 21.4 2510 THC120A4E0A0000 11.2/10.72 116,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1125 25.3 30THC – 575/3/60 – Three Phase – No Heat6 THC072AWE0A0000 11.5/11.32 72,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 861 13.5 2071/2 THC092AWE0A0000 11.5/11.32 90,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 899 14.8 1581/2 THC102AWE0A0000 11.5/11.32 102,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1036 16.6 2010 THC120AWE0A0000 11.2/10.72 116,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1125 19.9 25

1 HACR breaker per NEC.2 Downflow Airflow/Horizontal Airflow.3 SEER applies, 3-5 tons; EER applies 6-10 tons.* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.

Page 147: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PC-28Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Precedent™ Packaged CoolingConvertible 3-10 Tons

Table PC-28-A — Base Unit — High Efficiency — ReliaTel™ Microprocessor ControlsCooling Cabinet Shipping

Unit Performance33333 Capacity Dimensions (in.) Downflow Downflow Weight Max1Tons Ordering No. SEER/EER (Btuh) H x W x L Supply Return (Ibs.) MCA* Fuse*

THC – 208-230/3/60 – Three Phase – No Heat6 THC072A3R0A0000 11.5/11.32 72,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 861 34.8 5071/2 THC092A3R0A0000 11.5/11.32 90,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 899 38.1 5081/2 THC102A3R0A0000 11.5/11.32 102,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1036 42.3 5010 THC120A3R0A0000 11.2/10.72 116,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1125 48.6 60THC – 460/3/60 – Three Phase – No Heat6 THC072A4R0A0000 11.5/11.32 72,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 861 17.5 2571/2 THC092A4R0A0000 11.5/11.32 90,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 899 19.4 2581/2 THC102A4R0A0000 11.5/11.32 102,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1036 21.4 2510 THC120A4R0A0000 11.2/10.72 116,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1125 25.3 30THC – 575/3/60 – Three Phase – No Heat6 THC072AWR0A0000 11.5/11.32 72,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 861 13.5 2071/2 THC092AWR0A0000 11.5/11.32 90,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 899 14.8 1581/2 THC102AWR0A0000 11.5/11.32 102,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1036 16.6 2010 THC120AWR0A0000 11.2/10.72 116,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1125 19.9 25

1 HACR breaker per NEC.2 Downflow Airflow/Horizontal Airflow.3 SEER applies, 3-5 tons; EER applies 6-10 tons.* Information subject to change. Please confirm with current Product Data/Service Facts for current factory productio

Page 148: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PC-29 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Digit Description Order Number1-8 Main Assembly (see previous page)9 Unit Controls

Electro-Mechanical ......................................................... EUnit Controls -ReliaTel™ Micro-processor ....................... R

10 (See Heater Table below)11 Minor Design Sequence

First Sequence .............................................................. A12-13 Service Sequence

First Sequence (Factory Supplied) ................................. ✱,✱14 Fresh Air Selection

No Fresh Air ................................................................... 00-50% Manual Outside Air Damperw .............................. A0-50% Motorized Outside Air Damper .............................. B0-100% Economizer, Dry Bulb without

Barometric Relief 2 .................................................... C0-100% Economizer, Dry Bulb with

Barometric Relief2 .................................................... D0-100% Economizer, Reference Enthalpy

without Barometric Relief12 ....................................... E0-100%Economizer, Reference Enthalpy

with Barometric Relief12 ........................................... F0-100%Economizer, Comparative Enthalpy

without Barometric Relief 12 ..................................... G0-100%Economizer, Comparative Enthalpy

with Barometric Relief 12 ......................................... H15 Supply Fan/Drive Type/Motor

Standard Drive ............................................................... 0Oversized Motor ............................................................. 1Optional Belt Drive Motor (3 phase only) .......................... 2

16 Hinged Service Access & FiltersStandard Panels & Filters ................................................ 0Hinged Access Panels & Standard Filters ........................ AStandard Panels & 2" Pleated Filters ............................... BHinged Access Panels & 2" Pleated Filters ...................... C

17 Condenser Coil ProtectionStandard Coil ................................................................. 0Standard Coil with Hail Guard .......................................... 1Epoxy Coated Condenser Coil ........................................ 2Epoxy Coated Condenser Coil with Hail Guard ................ 3

18 Through the Base ProvisionsNo Through the Base Provisions ..................................... 0Through the Base Electricr ............................................ A

19 Disconnect/Circuit Breaker /Phase Monitor (3 phase only)No Disconnect/ Circuit Breaker/No Phase Monitor ............ 0Non-Fused Disconnectr ................................................ 1

Precedent™ PackagedCooling Convertible 3-10 Tons(Model Digit Numbers)

Circuit Breakerr ............................................................. 2Phase Monitort ............................................................. 3Phase Monitort & Non-Fused Disconnect Switch ............ 4Phase Monitort & Circuit Breaker ................................... 5

20 Convenience OutletNo Convenience Outlet ................................................... 0Unpowered Convenience Outlet ...................................... APowered Convenience Outlet (3 phase only)3 ................ B

21 Communications OptionsyNo Communications Interface ......................................... 0Trane Communications Interface ..................................... 1LonTalk® Communications Interface ................................. 2Novar 2024 Controls ....................................................... 3Novar 3051 Controls ....................................................... 4

22 Refrigeration System OptionStandard Refrigeration System ........................................ 0Thermal Expansion Valve (TXV) ...................................... ADehumidification (Hot Gas Reheat Coil)e ....................... B

23 Refrigeration ControlsNo Refrigeration Control .................................................. 0High Pressure Control6y .............................................. 1Frostat5 ........................................................................ 2Crankcase Heater ........................................................... 3High Pressure Control6y and Frostat5 ......................... 4High Pressure Control6y and Crankcase Heater ............ 5Frostat5 and Crankcase Heater6 .................................. 6High Pressure Control6y, Frostat5 and

Crankcase Heater6 ................................................... 724 Smoke Detector7y

No Smoke Detector ........................................................ 0Return Air Smoke Detector 89 ...................................... ASupply Air Smoke Detector .............................................. BSupply and Return Air Smoke Detectors 89 .................. C

25 Monitoring ControlsyNo Monitoring Control0 .................................................. 0Clogged Filter Switch0 ................................................... 1Fan Failure Switch0 ....................................................... 2Discharge Air Sensing Tube0 ......................................... 3Clogged Filter Switch and Fan Fail Switch0 .................... 4Clogged Filter Switch and Discharge

Air Sensing Tube0 ...................................................... 5Fan Fail Switch and Discharge Air Sensing Tube0 .......... 6Clogged Filter and Fan Fail Switches

and Discharge Air Sensing Tube0 ............................... 7Novar Return Air Sensorq .............................................. 8

1 Enthalpy control not available factory installed with electro-mechanical controls.2 Economizer with Barometric Relief is for downfllow configured units only. Order Economizer without

Barometric Relief for horizontal configuration. Barometric relief for horizontal configured units must be orderedas field installed accessory BAYBARM010A.

3 Requires use of Disconnect or Circuit Breaker.4 Standard refrigeration metering device - short orifice.5 Frostat cannot be field installed in electro-mechanical units.6 High Pressure control is standard on 3 phase units with scroll compressors and in TSC036A.7 Not available with BAYFRST001A High Temperature Stat accessory.8 The return air smoke detector may not fit up or work properly on the Convertible units when used in

conjunction with 3rd party accessories such as bolt on heat wheels, economizers and power exhaust. Do not

Digit Description Order Number

order the return air smoke detectors when using this type of accessory.9 Return Air Smoke Detector cannot be ordered with Novar Controls.0 These options are standard when ordering Novar Controls.q This options for use when ordering Novar Control only.w The manual outside air damper will ship factory supplied within the unit, but must be field installed.e Requires Selection of 2" Pleated Filters (Option B or C) for Digit 16.r Through the base electric required when ordering disconnect/circuit breaker options.t Phase Monitor is standard on T/Y/WSC060A3,4,W models. All other models Phase Monitor will be an option.y Not available with electro-mechanical unit controls.

Heaters (Digit 10)kW Nominal No.

Rating Digit BTUH Stages Used With208/240/1/60

3.7/5.0 (A) 12,800/17,100 1 T*C036-060A17.5/10.0 (D) 25,600/34,100 2 T*C036-060A1

10.3/13.8 (F) 35,300/47,100 2 T*C036-060A113.2/17.6 (G) 45,100/60,100 2 T*C048-060A1

208/240/3/604.5/6.0 (B) 13,400/20,500 1 T*C036-060A3

9.0/12.0 (E) 30,800/59,400 2 T*C036-060A313.2/17.6 (G) 44,600/59,400 2 T*C036-060A317.2/23.0 (J) 58,900/78,500 2 T*C060A36.75/9.0 (C) 23,000/30,700 1 T*C072-102A3

13.5/18.0 (G) 46,100/61,400 1 T*C072-120A320.3/27.0 (K) 69,000/92,100 2 T*C072-120A327.0/36.0 (N) 92,200/122,900 2 T*C072-120A340.5/54.0 (P) 138,200/184,300 2 T*C120A3

kW Nominal No.Rating Digit BTUH Stages Used With

460/3/606.0 (B) 20,500 1 T*C036-060A4

12.0 (E) 41,000 2 T*C036-060A417.6 (G) 59,400 2 T*C036-060A423.0 (J) 78,500 2 T*C060A49.0 (C) 30,700 1 T*C072-102A4

18.0 (G) 61,400 1 T*C072-120A427.0 (K) 92,100 2 T*C072-120A436.0 (N) 122,900 2 T*C072-120A454.0 (P) 184,300 2 T*C120A4

575/3/606.0 (B) 20,500 1 T*C036-060AW

12.0 (E) 41,000 2 T*C036-060AW17.6 (G) 59,400 2 T*C036-060AW23.0 (J) 78,500 2 T*C060AW9.0 (C) 30,700 1 T*C072-102AW

18.0 (G) 61,400 1 T*C072-120AW27.0 (K) 92,100 2 T*C072-120AW36.0 (N) 122,900 2 T*C072-120AW54.0 (P) 184,300 2 T*C120AW

Page 149: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PC-30Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Table PC-30-A — Accessory Electric Heaters – Unit with heater is single circuit / single point power entryModel Power kW Nominal No.Number Supply Rating BTUH Stages Used With11111

BAYHTRR105A 208/240/1/60 3.8/5.0 12,800/17,100 1 T*C036-060(A or E)1BAYHTRR110A 208/240/1/60 7.5/10.0 25,600/34,100 2 T*C036-060(A or E)1BAYHTRR114A 208/240/1/60 10.4/13.8 35,300/47,100 2 T*C036-060(A or E)1BAYHTRR118A 208/240/1/60 13.2/17.6 45,100/60,100 2 T*C048-060(A or E)1BAYHTRR306A 208/240/3/60 4.5/6.0 13,400/20,500 1 T*C036-060(A or E)3BAYHTRR312A 208/240/3/60 9.0/12.0 30,800/41,000 2 T*C036-060(A or E)3BAYHTRR318A 208/240/3/60 13.1/17.4 44,600/59,400 2 T*C036-060(A or E)3BAYHTRR323A 208/240/3/60 17.3/23.0 58,900/78,500 2 T*C060(A or E)3BAYHTRS309A 208/240/3/60 6.75/9.0 23,000/30,700 1 T*C072A3,TSC090,092A3BAYHTRS318A 208/240/3/60 13.5/18.0 46,100/61,400 1 T*C072A3,TSC090,092A3BAYHTRS327A 208/240/3/60 20.3/27.0 69,000/92,100 2 T*C072A3,TSC090,092A3BAYHTRS336A 208/240/3/60 27.0/36.0 92,200/122,900 2 T*C072A3,TSC090,092A3BAYHTRT309A 208/240/3/60 6.75/9.0 23,000/30,700 1 THC092A3,T*C102A3BAYHTRT318A 208/240/3/60 13.5/18.0 46,100/61,400 1 THC092A3,T*C102,120A3BAYHTRT327A 208/240/3/60 20.3/27.0 69,000/92,100 2 T*C102,120A3,THC092ABAYHTRT336A 208/240/3/60 27.0/36.0 92,200/122,900 2 THC092A3,T*C102,120A3BAYHTRT354A 208/240/3/60 40.5/54.0 138,200/184,300 2 T*C120A3

BAYHTRR406A 460/3/60 6.0 20,500 1 T*C036-060(A or E)4BAYHTRR412A 460/3/60 12.0 41,000 2 T*C036-060(A or E)4BAYHTRR418A 460/3/60 17.4 59,400 2 T*C036-060(A or E)4BAYHTRR423A 460/3/60 23.0 78,500 2 T*C060(A or E)4BAYHTRS409A 460/3/60 9.0 30,700 1 T*C072A4,TSC090,092A4BAYHTRS418A 460/3/60 18.0 61,400 1 T*C072A4,TSC090,092A4BAYHTRS427A 460/3/60 27.0 92,100 2 T*C072A4,TSC090,092A4BAYHTRS436A 460/3/60 36.0 122,900 2 T*C072A4,TSC090,092A4BAYHTRT409A 460/3/60 9.0 30,700 1 THC092A4,T*C102A4BAYHTRT418A 460/3/60 18.0 61,400 1 THC092A4,T*C102,120A4BAYHTRT427A 460/3/60 27.0 92,100 2 THC092A4,T*C102,120A4BAYHTRT436A 460/3/60 36.0 122,900 2 THC092A4,T*C102-120A4BAYHTRT454A 460/3/60 54.0 184,300 2 T*C120A4

BAYHTRRW06A 575/3/60 6.0 20,500 1 T*C036-060(A or E)WBAYHTRRW12A 575/3/60 12.0 41,000 2 T*C036-060(A or E)WBAYHTRRW18A 575/3/60 17.4 59,400 2 T*C036-060(A or E)WBAYHTRRW23A 575/3/60 23.0 78,500 2 T*C060(A or E)WBAYHTRSW09A 575/3/60 9.0 30,700 1 T*C072AW,TSC090,092AWBAYHTRSW18A 575/3/60 18.0 61,400 1 T*C072AW,TSC090,092AWBAYHTRSW27A 575/3/60 27.0 92,100 2 T*C072AW,TSC090,092AWBAYHTRSW36A 575/3/60 36.0 122,900 2 T*C072AW,TSC090,092AWBAYHTRTW18A 575/3/60 18.0 61,400 1 THC092AW,T*C102,120AWBAYHTRTW27A 575/3/60 27.0 92,100 2 THC092AW,T*C102,120AWBAYHTRTW36A 575/3/60 60 122,900 2 THC092AW,T*C102,120AWBAYHTRTW54A 575/3/60 54.0 184,300 2 T*C120AW

1 A=R-22, E=410A.

Precedent™ Packaged CoolingConvertible 3-10 Tons

Page 150: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PC-31 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Precedent™ Packaged CoolingConvertible 3-10 Tons

1 Kits contain all necessary parts to achieve desired level ofenthalpy control.

2 For ReliaTel™ microprocessor controlled units only.Must be factory installed for electromechanical controlledunits

3 Used for true discharge air sensing in both heating andcooling.Required for supply air tempering.

4 Lynn Haven Manufacturing has a No-Return policy for thisroof curb.

5 For use with ReliaTel™ controlled units only6 Barometric Relief accessory installs in ductwork for horizontal

configuration. For downflow configuration, installs in the unit'shorizontal return duct. See Installer's Guide for completeinstructions.

7 Cannot be used in conjunction with factory installedsmoke detector.

8 BAYABRD001C is required when ordering field installedaccessories Clogged Filter Switch (BAYDFPS003A), FanFail Switch (BAYDFPS004A), Discharge Air Sensing Kit(BAYTUBE004A) or Evaporator Defrost Control (Frostat)(BAYLOAM020B) Ventilation Override Kit(BAYVNOR001B) unless the following options are factoryinstalled: Frostat, Smoke Detector, Clogged Filter Switch,Fan Failure Switch, Discharge Air Sensing Kit. Thesefactory installed options include the ReliaTel™ OptionsModule.

9 BAYQACB009A adapts Voyager BAYCURB021B toaccept Precedent 3-5 ton unit. BAYQACB010A adaptsVoyager BAYCURB022B to accept Precedent unit.

0 For use with electromechanical controlled units only.q Cannot be used in conjunction with Barometric Relief.

Order Economizer without Barometric Relief.w BAYQACB012A adapts Voyager BAYCURB025A to

accept Precedent 6-10 ton unit. BAYQACB013A adaptsVoyager BAYCURB026A to accept Precedent 6-10 tonunit. BAYQACB011A adapts Voyager BAYCURB022 toaccept Precedent 6-10 ton unit.

e Interface allows a unit with ReliaTel™ Controls tocommunicate with Tracer 100, Tracker, VariTrac II, and isthe preferred method of communication to Tracer Summit.

r Activated on Power On.t Field installed accessory requires economizer.y The manual outside air damper will ship factory supplied

within the unit, but must be field installed.u A=R-22, E=410A.* Either Standard or High Efficiency.

Table PC-31-A — AccessoriesModel Number Description Used Withuuuuu

BAYABRD001C .............. ReliaTel™ Options Module .................................................... See Note8BAYASCT0010r* .......... Anti-Short-Cycle Timer .......................................................... T*C036-060(A or E)_EBAYBARM010A6 ........... Barometric Relief ................................................................... T*C036-060(A or E)BAYBARM011A6 ........... Barometric Relief ................................................................... T*C072-120ABAYCCHT010B ............... Crankcase Heater .................................................................. THC072A3, TSC048-060(A or E)1,A3, T*C072-120A3BAYCCHT011B ............... Crankcase Heater .................................................................. THC072A4,AW, TSC048-060(A or E)4,AW,T*C072-120A4,AWBAYCCHT012A .............. Crankcase Heater .................................................................. T*C090A3BAYCCHT013A .............. Crankcase Heater .................................................................. T*C090A4BAYCCHT014A ............... Crankcase Heater .................................................................. T*C090AWBAYCO2K001B5t ......... CO2 Sensor Kit, Wall Mounted ............................................... T*C036-060(A or E)_R, T*C072-120A_R w/EconomizerBAYCO2K003B5t ......... CO2 Sensor Kit, Duct Mounted .............................................. T*C036-060(A or E)_R, T*C072-120A_R w/EconomizerBAYCURB042A4 ........... Roof Curb .............................................................................. T*C036-060(A or E)BAYCURB043A4 ........... Roof Curb .............................................................................. T*C072-120ABAYDFPS003A58 ......... Clogged Filter Switch ............................................................. T*C036-060(A or E), T*C072-120A_RBAYDFPS004A58 ......... Fan Failure Switch ................................................................. T*C036-060(A or E), T*C072-120A_RBAYDMPR051A5 ........... 0-50% Motorized Outside Air Damper ................................... T*C036-060(A or E)_RBAYDMPR052A0 ........... 0-50% Motorized Outside Air Damper ................................... T*C036-060(A or E)_EBAYDMPR053By ........... 0-50% Manual Outside Air Damper ....................................... T*C036-060(A or E)BAYDMPR054A5 ........... 0-50% Motorized Outside Air Damper ................................... T*C072-120A_RBAYDMPR055A0 ........... 0-50% Motorized Outside Air Damper ................................... T*C072-120A_EBAYDMPR056By ........... 0-50% Manual Outside Air Damper ....................................... T*C072-120ABAYECON085A5 ........... 0-100% Dry Bulb Economizer without Barometric Relief ...... T*C036-060(A or E)_RBAYECON086A0 ........... 0-100% Dry Bulb Economizer without Barometric Relief ...... T*C036-060(A or E)_EBAYECON087A5 ........... 0-100% Dry Bulb Economizer without Barometric Relief ..... T*C072-120A_RBAYECON088A0 ........... 0-100% Dry Bulb Economizer without Barometric Relief ..... T*C072-120A_EBAYENTH005A15 ......... Reference Enthalpy Kit .......................................................... BAYECON085A, 087ABAYENTH006A15 ......... Comparative Enthalpy Kit ...................................................... BAYECON085A, 087ABAYENTH001A ............... Enthalpy Control (Solid State) ............................................... BAYECON0086A, 088ABAYFRST001A50 ......... High Temperature Stat .......................................................... T*C036-060(A or E), T*C072-120A_RBAYGARD036B .............. Condenser Coil Hail Guard .................................................... TSC036-060(A or E), THC036,048(A or E)BAYGARD037B .............. Condenser Coil Hail Guard .................................................... THC060(A or E)BAYGARD040B .............. Condenser Coil Hail Guard .................................................... THC072, 090BAYGARD041B .............. Condenser Coil Hail Guard .................................................... TSC102,120A, THC092,102,120ABAYHSDR012A .............. High Static Drive Kit ............................................................... T*C072A, TSC090,092ABAYHSMT073A .............. .45 HP Oversized motor kit .................................................... T*C036(A or E)1,(A or E)3BAYHSMT074A .............. .45 HP Oversized motor kit .................................................... T*C036(A or E)4BAYHSMT075A .............. .45 HP Oversized motor kit .................................................... T*C036(A or E)WBAYHSMT076A .............. .75 HP Oversized motor kit .................................................... T*C048(A or E)1,(A or E)3BAYHSMT077A .............. .75 HP Oversized motor kit .................................................... T*C048(A or E)4BAYHSMT078A .............. .75 HP Oversized motor kit .................................................... T*C048(A or E)WBAYHSMT079A .............. 1.2 HP Oversized motor kit .................................................... T*C060(A or E)1,(A or E)3BAYHSMT080A .............. 1.2 HP Oversized motor kit .................................................... T*C060(A or E)4BAYHSMT081A .............. 1.2 HP Oversized motor kit .................................................... T*C060(A or E)WBAYHSMT082A .............. 2 HP Oversized motor kit ....................................................... T*C072A3, A4BAYHSMT083A .............. 2 HP Oversized motor kit ....................................................... T*C072AWBAYHSMT084A .............. 3 HP Oversized motor kit ....................................................... T*C090, 092A3, A4BAYHSMT085A .............. 3 HP Oversized motor kit ....................................................... T*C090, 092AWBAYHSMT086A .............. 3 HP Oversized motor kit ....................................................... T*C102A3,A4, THC092A3,A4BAYHSMT087A .............. 3 HP Oversized motor kit ....................................................... T*C102AW, THC092AWBAYHSMT088A .............. 5 HP Oversized motor kit ....................................................... T*C120A3, A4BAYHSMT089A .............. 5 HP Oversized motor kit ....................................................... T*C120AWBAYICSI003A5e ............ Trane Communications Interface (TCI) .................................. T*C036-060(A or E), T*C072-120A_RBAYKSKT255A ............... Quick Start Kit ........................................................................ THC060A1, TSC048-060A1BAYKSKT256A ............... Quick Start Kit ........................................................................ TSC036(A or E)1BAYLOAM020B258 ..... Evaporator Defrost Control (Frostat) ...................................... T*C036-060(A or E), T*C072-120A_RBAYLTCI002B5 .............. LonTalk® Communications Interface (LCI) ............................. T*C036-060(A or E), T*C072-120A_RBAYPWRX026Aq ........... Power Exhaust ...................................................................... T*072-120A3BAYPWRX027Aq ........... Power Exhaust ...................................................................... T*072-120A4BAYPWRX028Aq ........... Power Exhaust ...................................................................... T*072-120AWBAYQACB009A49 ........ Quick Adapt Roof Curb .......................................................... T*C036-060(A or E)BAYQACB010A49 ........ Quick Adapt Roof Curb .......................................................... T*C036-060(A or E)BAYQACB011A4w ........ Quick Adapt Roof Curb .......................................................... T*C072-120ABAYQACB012A4w ........ Quick Adapt Roof Curb .......................................................... T*C072-120ABAYQACB013A4w ........ Quick Adapt Roof Curb .......................................................... T*C072-120ABAYSTAT0235 ............... Remote Potentiometer ........................................................... BAYECON085A, 087ABAYSERV001A5 ............ Selective Resistance Service Tester ..................................... T*C036-060(A or E), T*C072-120A_RBAYSENS016A5 ............ Temperature Sensor .............................................................. T*C036-060(A or E)_RBAYTUBE005A358 ...... Discharge Air Sensing Kit ...................................................... T*C036-060(A or E)_RBAYTUBE007A358 ....... Discharge Air Sensing Kit ...................................................... T*C072-120_RBAYVNOR001B58t ..... Ventilation Override Kit w/ReliaTel™ options module ............ T*C036-060(A or E), T*C072-120A_R

Page 151: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PC-32Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Table PC-32-A — Zone Sensors for ReliaTel™ Controlled UnitsModelNumber Description Used With

BAYMTPL003B Retrofit Wall Cover Plate Kit 7.25" x 6.0" BAYSENS019CBAYMTPL004B Retrofit Wall Cover Plate Kit 4.75" x 4.75" BAYSENS006,008010B,013,014C,017BBAYSENS006B Single Setpoint Manual Changeover T*C036-060_RBAYSENS008B Dual Setpoint Manual or Auto Changeover T*C036-060_RBAYSENS010B Dual Setpoint Man. or Auto Changeover with System

Function Lights T*C036-120_RBAYSENS019C Programmable Night Setback w/System Function Lights T*C036-120_RBAYSENS013C1 Room Sensor w/ Override and Cancel Buttons T*C036-120_RBAYSENS014C1 Room Sensor w/ Temp. Adjustment with Override and

Cancel Buttons T*C036-120_RBAYSENS017B Remote Room Sensor BAYSENS006B,008B,010B, & 019CBAYSENS032A8 Dual Thermistor Remote Zone Sensor T*C036-120A_RBAYSENS035A8 Digital Display Zone Sensor T*C036-120A_RBAYSENS036A7 Wall-Mounted Humidity Zone Sensor THC120A,3,4,WRBAYSENS037A7 Duct-Mounted Humidity Zone Sensor THC120A,3,4,WR

Table PC-32-B — ThermostatsModelNumber Description Used With

BAY24X042 DPDT Fan and Electric Heat Relay BAYSTAT008,010BAY28X1904 Locking Thermostat Cover for up to 4 units Room ThermostatsBAYSTAT040B2 Programmable Thermostat T*C036-120ABAYBASE008A Subbase 1-Stage Heating/Cooling BAYSTAT040BBAYBASE006A Subbase 2-Stage Heating/Cooling BAYSTAT040BBAYSENS033A Remote Wall Sensor BAYSTAT040BBAYSENS034A Remote Duct Sensor BAYSTAT040BBAYSTAT0083 Manual 1-Stage Heating/Cooling T*C036-120ABAYSTAT0103 Auto 2-Stage Heating/Cooling T*C036-120ATCONT200AN11AA Electronic 1 Htg/1 Clg (Non Prog) T*C036-090A

1 Used with Integrated ComfortTM Systems, any unit type. These sensors do not work with TCM. Consult BASD Marketing for them.2 Requires use of BAYBASE006A or BAYBASE008A.3 Requires DPDT Fan and Electric Heat Relay BAY24x042 when using electric heat.4 Do not use with programmable thermostats.5 Specially designed for electric heat applications (instant on fan).6 Use only with electromechanical unit controls.7 For use with Dehumidification (Hot Gas Reheat) Coil Option.8 For use with ReliaTel™ Controls only.*Either standard or high efficiency models

Precedent™ Packaged CoolingConvertible 3-10 Tons

Page 152: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PC-33 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Light Commercial Packaged CoolingNew Model Reference Chart

Table PC-33-A — Quick Reference

Precedent™ Precedent™Voyager Horizontal Voyager Downflow Controls Ordering Number Service Model Number

TCD036C100B Micro-Proc TSC036*1R0A0000 TSC036*1R0A**000000000000Electro-Mech TSC036*1E0A0000 TSC036*1E0A**000000000000

TCD036C300B Micro-Proc TSC036*3R0A0000 TSC036*3R0A**000000000000Electro-Mech TSC036*3E0A0000 TSC036*3E0A**000000000000

TCD036C400B Micro-Proc TSC036*4R0A0000 TSC036*4R0A**000000000000Electro-Mech TSC036*4E0A0000 TSC036*4E0A**000000000000

TCH048C100B TCD048C100B Micro-Proc TSC048*1R0A0000 TSC048*1R0A**000000000000Electro-Mech TSC048*1E0A0000 TSC048*1E0A**000000000000

TCH048C300B TCD048C300B Micro-Proc TSC048*3R0A0000 TSC048*3R0A**000000000000Electro-Mech TSC048*3E0A0000 TSC048*3E0A**000000000000

TCH048C400B TCD048C300B Micro-Proc TSC048*4R0A0000 TSC048*4R0A**000000000000Electro-Mech TSC048*4E0A0000 TSC048*4E0A**000000000000

TCH048CW00B TCD048CW00B Micro-Proc TSC048*WR0A0000 TSC048*WR0A**000000000000Electro-Mech TSC048*WE0A0000 TSC048*WE0A**000000000000

TCH060C100B TCD060C100B Micro-Proc TSC060*1R0A0000 TSC060*1R0A**000000000000Electro-Mech TSC060*1E0A0000 TSC060*1E0A**000000000000

TCH060C300B TCD060C300B Micro-Proc TSC060*3R0A0000 TSC060*3R0A**000000000000Electro-Mech TSC060*3E0A0000 TSC060*3E0A**000000000000

TCH060C400B TCD060C400B Micro-Proc TSC060*4R0A0000 TSC060*4R0A**000000000000Electro-Mech TSC060*4E0A0000 TSC060*4E0A**000000000000

TCH060CW00B TCD060CW00B Micro-Proc TSC060*WR0A0000 TSC060*WR0A**000000000000Electro-Mech TSC060*WE0A0000 TSC060*WE0A**000000000000

*Digit 7- A=R-22, E=410A.NOTE: N/A indicates that an Ordering Number has not yet been set up for the indicated model.

Page 153: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PC-34Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Light Commercial Packaged CoolingNew Model Reference Chart

Table PC-34-A — Quick Reference

Precedent™ Precedent™Voyager Horizontal Voyager Downflow Controls Ordering Number Service Model Number

TCH074C300B TCD074C300B Micro-Proc TSC072A3R0A0000 TSC072A3R0A**000000000000Electro-Mech TSC072A3E0A0000 TSC072A3E0A**000000000000

TCH074C400B TCD074C400B Micro-Proc TSC072A4R0A0000 TSC072A4R0A**000000000000Electro-Mech TSC072A4E0A0000 TSC072A4E0A**000000000000

W 575 Volt Micro-Proc TSC072AWR0A0000 TSC072AWR0A**000000000000Electro-Mech TSC072AWE0A0000 TSC072AWE0A**000000000000

TCH075C300B TCD075C300B Micro-Proc THC072A3R0A0000 THC072A3R0A**000000000000Electro-Mech THC072A3E0A0000 THC072A3E0A**000000000000

TCH075C400B TCD075C400B Micro-Proc THC072A4R0A0000 THC072A4R0A**000000000000Electro-Mech THC072A4E0A0000 THC072A4E0A**000000000000

TCH075CW00B TCD075CW00B Micro-Proc THC072AWR0A0000 THC072AWR0A**000000000000Electro-Mech THC072AWE0A0000 THC072AWE0A**000000000000

TCH090D300B TCD090D300B Micro-Proc TSC090A3R0A0000 TSC090A3R0A**000000000000Electro-Mech TSC090A3E0A0000 TSC090A3E0A**000000000000

TCH090D400B TCD090D400B Micro-Proc TSC090A4R0A0000 TSC090A4R0A**000000000000Electro-Mech TSC090A4E0A0000 TSC090A4E0A**000000000000

TCH090DW00B TCD090DW00B Micro-Proc TSC090AWR0A0000 TSC090AWR0A**000000000000Electro-Mech TSC090AWE0A0000 TSC090AWE0A**000000000000

TCH091D300B TCD091D300B Micro-Proc THC090A3R0A**000000000000Electro-Mech THC090A3E0A**000000000000

TCH091D400B TCD091D400B Micro-Proc THC090A4R0A**000000000000Electro-Mech THC090A4E0A**000000000000

W 575 Volt Micro-Proc THC090AWR0A**000000000000Electro-Mech THC090AWE0A**000000000000

TCH102C300A TCD102C300A Micro-Proc TSC102A3R0A0000 TSC102A3R0A**000000000000Electro-Mech TSC102A3E0A0000 TSC102A3E0A**000000000000

TCH102C400A TCD102C400A Micro-Proc TSC102A4R0A0000 TSC102A4R0A**000000000000Electro-Mech TSC102A4E0A0000 TSC102A4E0A**000000000000

TCH102CW00A TCD102CW00A Micro-Proc TSC102AWR0A0000 TSC102AWR0A**000000000000Electro-Mech TSC102AWE0A0000 TSC102AWE0A**000000000000

TCH103C300A TCD103C300A Micro-Proc THC102A3R0A0000 THC102A3R0A**000000000000Electro-Mech THC102A3E0A0000 THC102A3E0A**000000000000

TCH103C400A TCD103C400A Micro-Proc THC102A4R0A0000 THC102A4R0A**000000000000Electro-Mech THC102A4E0A0000 THC102A4E0A**000000000000

TCH103CW00A TCD103CW00A Micro-Proc THC102AWR0A0000 THC102AWR0A**000000000000Electro-Mech THC102AWE0A0000 THC102AWE0A**000000000000

TCH120C300A TCD120C300A Micro-Proc TSC120A3R0A0000 TSC120A3R0A**000000000000Electro-Mech TSC120A3E0A0000 TSC120A3E0A**000000000000

TCH120C400A TCD120C400A Micro-Proc TSC120A4R0A0000 TSC120A4R0A**000000000000Electro-Mech TSC120A4E0A0000 TSC120A4E0A**000000000000

TCH120CW00A TCD120CW00A Micro-Proc TSC120AWR0A0000 TSC120AWR0A**000000000000Electro-Mech TSC120AWE0A0000 TSC120AWE0A**000000000000

TCH121C300A TCD121C300A Micro-Proc THC120A3R0A0000 THC120A3R0A**000000000000Electro-Mech THC120A3E0A0000 THC120A3E0A**000000000000

TCH121C400A TCD121C400A Micro-Proc THC120A4R0A0000 THC120A4R0A**000000000000Electro-Mech THC120A4E0A0000 THC120A4E0A**000000000000

TCH121CW00A TCD121CW00A Micro-Proc THC120AWR0A0000 THC120AWR0A**000000000000Electro-Mech THC120AWE0A0000 THC120AWE0A**000000000000

NOTE: N/A indicates that an Ordering Number has not yet been set up for the indicated model.

Page 154: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PC-35 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

ReliaTel™ Controls for Precedent™,Precedent™ 13 SEER and Voyager™Packaged Unit Protection/Operation Timings and Features

Alternating Lead/Lag – Dual Compressor Models Only —During periods of part load operation, each compressor cyclesalternately as circuit number one, equalizing compressor wear and runtime. Enabled by cutting the wire (BLUE) at (RTRM) junction numberJ3-8. Standard

Anti Short Cycle Timer (ASCT) Function — Provides a three (3)minute minimum “ON” time and a three (3) minute minimum “OFF” timefor compressors, enhances compressor reliability by ensuring proper oilreturn. Standard

Built In Evaporator Defrost Control (EDC) Function —Provides low ambient cooling down to 0°F. Standard

Built In Fan Delay Relay (FDR) Function — Provides custom indoorfan timing sequences for the different types of equipment, enhancingefficiency and reliability. Standard

Built In Night Set Back and Unoccupied Functions1 — When usinga standard dual setpoint/auto change over Zone Sensor Module (ZSM),this function is enabled by applying a short across terminal J6-11 andJ6-12. Sets cooling setpoint up a minimum of 7°F, sets heating setpointback a minimum of 7°F, forces outside air damper (if present) minimumposition to zero, and forces fan operation to automatic. Accessory(requires time clock accessory or field supplied/installed switch orcontacts).

Built In “TEST” Mode — Aids in quick verification of systemand control operation, exercises both hardware and software(no special tools required). Standard

Built In Unoccupied Mode1 — When using a standard singlesetpoint/manual change over Zone Sensor Module (ZSM), this functionis enabled by applying a short across terminal J6-11 and J6-12. Forcesoutside air damper (if present) minimum position to zero, forces fanoperation to automatic. Accessory (requires time clock accessory orfield supplied/installed switch or contacts.)

Direct Digital Control (DDC)1 — Proportional Integral (PI) control.Proportional – sets corrective action proportional to deviationfrom setpoint. Integral – fine tunes the rate of corrective actionproportional to the error (results in superior space temperature control).Standard

Economizer Preferred Cooling1 — Provides fully integratedoperation if required. Will not turn on a compressor with the economizer,if the space is recovering adequately with the economizer alone (0.2°F/minute). Allows the equipment to be utilized in more varied applications.Standard with economizer accessory.

Emergency Stop Terminals On Low Voltage Terminal Board(LTB-5 and LTB-6) — Provides a convenient point to disable theequipment completely, and immediately. Still provides communication toBAS. Standard

Heat Pump Smart Recovery and Smart Staging1 — Inhibitsauxiliary heat operation if the space is recovering adequately(0.1°F/minute) with the heat pump alone, providing considerablesavings in operating costs. Standard

Heat Pump Soft Start — Provides a smooth transition into heatingafter defrost, minimizing noise and compressor stress associated withswitch over. Standard

Increased Reliability — Fewer components (moving electro-mechanical parts), less likelihood of equipment down time orfailure. Standard

Integral Electric Heat Staging1 — Stages electric heaters “OFF”and “ON”, eliminating the use of outdated sequencers. Standard

Intelligent Fallback1 — A built in Default Control provides adaptiveoperation, which allows the equipment to continueto operate, providing comfort in the event of certain componentfailures. Also, allows emergency operation without a Zone SensorModule (ZSM). Standard

Low Ambient Start Timer (LAST) Function — Bypasses lowpressure control when a compressor starts, eliminating nuisancecompressor lock outs. Standard

Lower Installation Cost — Using a standard Zone Sensor Module(ZSM), control voltage wiring may be run up to five (5) times furtherthan any electromechanical system, with no increase in wire gauge.Example: Electromechanical System –30 feet maximum using 22 gauge wire. Micro Control System – 150feet using 22 gauge wire. Standard

On Board Diagnostics1 — Assist with equipment troubleshooting, ifa problem occurrence should take place. Standard

Remote Sensing1 — All standard Zone Sensor Modules(ZSMs) have remote sensing capabilities, typically achieved by usingan expensive program-mable thermostat and remote sensor withelectromechanical equipment. Accessory (requires use of remotesensor).

Selectable Economizer Dry Bulb Change Over — Allows thecapability of selecting the following dry bulb change over points:63, 67, 70 or 73°F. Standard with economizer accessory.

Space Temperature Averaging1 — All standard Zone SensorModules (ZSMs) have space temperature averaging capabilities,typically achieved by using an expensive programmable thermostatand minimum of four (4) remote sensors with electromechanicalequipment. Averaging with ReliaTel™ can be achieved with two(2) sensors.

Supply Air Tempering1 — A built in feature, once enabled onlythrough an ICS device, may also be enabled using a digital orprogrammable Zone Sensor Module. When in the HEAT mode(and not actively heating), if supply air temperature drops 10°F belowthe heating setpoint, heat is turned on until supply air temperaturerises to a point 10°F above the heating setpoint. Provides temperateair during the “OFF” cycle, and eliminatescold air dumping from supply ducts. Extremely effective whenintroducing any quantity of fresh air. Standard when using a RTOM,ICS device, digital, or programmable Zone Sensor Module.

Time Delay Relay (TDR) Function — Provides an incrementalstaging delay between compressors, minimizes equipment currentinrush and consumption by keeping compressors from startingsimultaneously. Standard

Low Pressure and High Pressure Compressor Lockout — 3 tripswill lockout control.

1 Denotes features lost from utilizing standard conventional stat.

Page 155: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PC-36Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Micro Control for Precedent™,Precedent™ 13 SEER and Voyager™Operation With A Thermostat

• Direct Digital Control (DDC) –Proportional Integral (PI) control islost, equipment is controlled by athermostat or generic buildingautomation system device.

• Intelligent Fall back is lost, if a failureoccurs in the device controlling theequipment, operation will cease.

• Installation is more costly, with theaddition of a thermostat or genericcontrol, the control wiring size must beincreased.

• Heat Pump Smart Recovery andSmart Staging is lost, Heat Pumpoperation becomes more costly unlessgeneric control being applied canaccomplish this.

• Remote Sensing capabilities are lost,unless generic control being appliedcan accomplish this.

When the ReliaTel™ RTRM Thermostat Interface is used, equipment operationdiffers significantly. The basic equipment protection features remain intact, and thefollowing features and benefits are lost:

• Low ambient disabled economizer andsecond condensing fan cyclingcapability.

• Space Temperature Averagingcapabilities are lost, unless genericcontrol being applied can accomplishthis.

• Supply Air Tempering feature is lost,discharge air temperature may be coldwhen not actively heating if outdoor airis being introduced through theequipment.

• Built In Night Set Back and Unoccu-pied functions are lost, unless genericcontrol being applied can accomplishthis.

• Built In Unoccupied Mode is lost,unless generic control being appliedcan accomplish this.

• Economizer Preferred Cooling Featureis lost, all compressor operation islocked out below 50°F.

Page 156: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PC-37 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Standard Features:• Trane built scroll compressors on all 3-5 ton units• Colored and numbered wiring• Provisions for through the Base Condensate Drain Connections• Patented Hybrid Condenser Coil for easy cleaning• 1" throwaway filters provided on 3-5 ton units• Liquid Line Refrigerant Drier• Operating Charge of R-22• IAQ Sloped Drain Pans• Single point power for Electric Heat• Low Ambient to 40°F on Electromechanical models• Low Ambient to 0°F on Microprocessor models• 5 - year Limited Compressor Warranty• 1 - year Limited Parts Warranty

Added Flexibility

• Electromechanical or ReliaTel™ controls (See page PC-35 for ReliaTel™Control Information)

• Convertible airflow (ships in downflow application)• Fork lift openings on three sides of unit• Belt drive - standard or oversized motors• We don’t prepackage options• Choose options tailored to suit each job —pay only for what is needed• Units ship with options installed —and within our standard ship cycle time

Factory Installed Options

• Through-the-Base — Electrical• Convenience Outlet — Powered or unpowered• Unit Disconnect Switch• Smoke Detectors — Supply, return, or both• Condenser Coil Coating• Hinged Access Service Panels• Discharge Air Sensor• Fan Fail and Clogged Filter Switches• Condenser Coil Guard — Hail Protection Quality• TXV thermal expansion valve and split face evaporator coil standard• Dehumidification Hot Gas Reheat Coil• Novar Controls• TCI (Trane Communication Interface)• LonTalk (Communication Interface)• 2" Pleated Media filters• Phase Monitor

The same Trane Quality andReliability … with added Flexibility!

Precedent™ 3-5 ton 13 SEER R-22Packaged Cooling

FeaturingA New Look for a New Century

Beveled TopSmoother DesignSmall compact cabinetRecessed access handles

Page 157: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PC-38Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Precedent™ Packaged CoolingConvertible 3-5 Tons 13 SEER R-22

Table PC-38-A — Base Unit — 13 SEER High Efficiency — ElectromechanicalCooling Cabinet Shipping

Unit Performance33333 Capacity Dimensions (in.) Downflow Downflow Weight Max1Tons Ordering No. SEER/EER (Btuh) H x W x L Supply Return (Ibs.) MCA* Fuse*

THC – 208-230/3/60 – Three Phase – No Heat3 THC033A3E0A0000 13.0 38,000 32 x 44 x 70 18 x 15.5 24 x 14 549 19.9 304 THC043A3E0A0000 13.0 49,800 32 x 44 x 70 18 x 15.5 24 x 14 591 22.6 355 THC063A3E0A0000 13.0 62,400 36 x 44 x 70 18 x 15.5 24 x 14 641 28.8 45THC – 460/3/60 – Three Phase – No Heat3 THC033A4E0A0000 13.0 38,000 32 x 44 x 70 18 x 15.5 24 x 14 549 10.4 154 THC043A4E0A0000 13.0 49,800 32 x 44 x 70 18 x 15.5 24 x 14 591 11.8 155 THC063A4E0A0000 13.0 62,400 36 x 44 x 70 18 x 15.5 24 x 14 641 14.3 20THC – 575/3/60 – Three Phase – No Heat3 THC033AWE0A0000 13.0 38,000 32 x 44 x 70 18 x 15.5 24 x 14 549 7.7 154 THC043AWE0A0000 13.0 49,800 32 x 44 x 70 18 x 15.5 24 x 14 591 8.5 155 THC063AWE0A0000 13.0 62,400 36 x 44 x 70 18 x 15.5 24 x 14 641 11.4 15

Table PC-38-B — Base Unit — 13 SEER High Efficiency — ReliaTel™ Microprocessor ControlsCooling Cabinet Shipping

Unit Performance33333 Capacity Dimensions (in.) Downflow Downflow Weight Max1Tons Ordering No. SEER/EER (Btuh) H x W x L Supply Return (Ibs.) MCA* Fuse*THC – 208-230/3/60 – Three Phase – No Heat3 THC033A3R0A0000 13.0 38,000 32 x 44 x 70 18 x 15.5 24 x 14 549 19.9 304 THC043A3R0A0000 13.0 49,800 32 x 44 x 70 18 x 15.5 24 x 14 591 22.6 355 THC063A3R0A0000 13.0 62,400 36 x 44 x 70 18 x 15.5 24 x 14 641 28.8 45THC – 460/3/60 – Three Phase – No Heat3 THC033A4R0A0000 13.0 38,000 32 x 44 x 70 18 x 15.5 24 x 14 549 10.4 154 THC043A4R0A0000 13.0 49,800 32 x 44 x 70 18 x 15.5 24 x 14 591 11.8 155 THC063A4R0A0000 13.0 62,400 36 x 44 x 70 18 x 15.5 24 x 14 641 14.3 20THC – 575/3/60 – Three Phase – No Heat3 THC033AWR0A0000 13.0 38,000 32 x 44 x 70 18 x 15.5 24 x 14 549 7.7 154 THC043AWR0A0000 13.0 49,800 32 x 44 x 70 18 x 15.5 24 x 14 591 8.5 155 THC063AWR0A0000 13.0 62,400 36 x 44 x 70 18 x 15.5 24 x 14 641 11.4 15

1 HACR breaker per NEC.2 Downflow Airflow/Horizontal Airflow.3 SEER applies, 3-5 tons; EER applies 6-10 tons.* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.

Page 158: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PC-39 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Heaters (Digit 10)kW Nominal No.

Rating Digit BTUH Stages Used With208/240/3/60

4.5/6.0 (B) 13,400/20,500 1 THC033-063A39.0/12.0 (E) 30,800/59,400 2 THC033-063A313.2/17.6 (G) 44,600/59,400 2 THC033-063A317.2/23.0 (J) 58,900/78,500 2 THC063A3

Digit Description Order Number1-8 Main Assembly (see previous page)9 Unit Controls

Electro-Mechanical ......................................................... EUnit Controls -ReliaTel™ Micro-processor ....................... R

10 (See Heater Table below)11 Minor Design Sequence

First Sequence .............................................................. A12-13 Service Sequence

First Sequence (Factory Supplied) ................................. ✱,✱14 Fresh Air Selection

No Fresh Air ................................................................... 00-50% Manual Outside Air Damperw .............................. A0-50% Motorized Outside Air Damper .............................. B0-100% Economizer, Dry Bulb without

Barometric Relief 2 .................................................... C0-100% Economizer, Dry Bulb with

Barometric Relief2 .................................................... D0-100% Economizer, Reference Enthalpy

without Barometric Relief12 ....................................... E0-100%Economizer, Reference Enthalpy

with Barometric Relief12 ........................................... F0-100%Economizer, Comparative Enthalpy

without Barometric Relief 12 ..................................... G0-100%Economizer, Comparative Enthalpy

with Barometric Relief 12 ......................................... H15 Supply Fan/Drive Type/Motor

Standard Drive ................................................................ 016 Hinged Service Access & Filters

Standard Panels & Filters ................................................ 0Hinged Access Panels & Standard Filters ........................ AStandard Panels & 2" Pleated Filters ............................... BHinged Access Panels & 2" Pleated Filters ...................... C

17 Condenser Coil ProtectionStandard Coil ................................................................. 0Standard Coil with Hail Guard .......................................... 1Epoxy Coated Condenser Coil ........................................ 2Epoxy Coated Condenser Coil with Hail Guard ................ 3

18 Through the Base ProvisionsNo Through the Base Provisions ..................................... 0Through the Base Electricr ............................................ A

19 Disconnect/Circuit Breaker /Phase Monitor (3 phase only)No Disconnect/ Circuit Breaker/No Phase Monitor ............ 0Non-Fused Disconnectr ................................................ 1Circuit Breakerr ............................................................. 2

Phase Monitort ............................................................. 3Phase Monitort & Non-Fused Disconnect Switch ............ 4Phase Monitort & Circuit Breaker ................................... 5

20 Convenience OutletNo Convenience Outlet ................................................... 0Unpowered Convenience Outlet ...................................... APowered Convenience Outlet (3 phase only)3 ................ B

21 Communications OptionsyNo Communications Interface ......................................... 0Trane Communications Interface ..................................... 1LonTalk® Communications Interface ................................. 2Novar 2024 Controls ....................................................... 3Novar 3051 Controls ....................................................... 4

22 Refrigeration System OptionStandard Refrigeration System with Thermal Expansion Valve .............................................. 0Dehumidification (Hot Gas Reheat Coil)e ........................ B

23 Refrigeration ControlsNo Refrigeration Control .................................................. 0High Pressure Control6y .............................................. 1Frostat5 ........................................................................ 2Crankcase Heater ........................................................... 3High Pressure Control6y and Frostat5 ......................... 4High Pressure Control6y and Crankcase Heater ............ 5Frostat5 and Crankcase Heater6 .................................. 6High Pressure Control6y, Frostat5 and

Crankcase Heater6 ................................................... 724 Smoke Detector7y

No Smoke Detector ........................................................ 0Return Air Smoke Detector 89 ...................................... ASupply Air Smoke Detector .............................................. BSupply and Return Air Smoke Detectors 89 .................. C

25 Monitoring ControlsyNo Monitoring Control0 .................................................. 0Clogged Filter Switch0 ................................................... 1Fan Failure Switch0 ....................................................... 2Discharge Air Sensing Tube0 ......................................... 3Clogged Filter Switch and Fan Fail Switch0 .................... 4Clogged Filter Switch and Discharge

Air Sensing Tube0 ...................................................... 5Fan Fail Switch and Discharge Air Sensing Tube0 .......... 6Clogged Filter and Fan Fail Switches

and Discharge Air Sensing Tube0 ............................... 7Novar Return Air Sensorq .............................................. 8

1 Enthalpy control not available factory installed with electro-mechanical controls.2 Economizer with Barometric Relief is for downfllow configured units only. Order Economizer without

Barometric Relief for horizontal configuration. Barometric relief for horizontal configured units mustbe ordered as field installed accessory BAYBARM010A.

3 Requires use of Disconnect or Circuit Breaker.4 Standard refrigeration metering device - short orifice.5 Frostat cannot be field installed in electro-mechanical units.6 High Pressure control is standard on 3 phase units with scroll compressors.7 Not available with BAYFRST001A High Temperature Stat accessory.8 The return air smoke detector may not fit up or work properly on the Convertible units when used in

conjunction with 3rd party accessories such as bolt on heat wheels, economizers and powerexhaust. Do not order the return air smoke detectors when using this type of accessory.

Digit Description Order Number

9 Return Air Smoke Detector cannot be ordered with Novar Controls.0 These options are standard when ordering Novar Controls.q This options for use when ordering Novar Control only.w Factory Supplied Field Installed.The manual outside air damper will ship factory supplied within the

unit, but must be field installed.e Requires Selection of 2" Pleated Filters (Option B or C) for Digit 16.r Through the base electric required when ordering Disconnect/Circuit Breaker options.t Phase Monitor is standard on T/Y/WSC060A3,4,W models. All other models Phase Monitor will be

an option.y Not available with electro-mechanical unit controls.

kW Nominal No.Rating Digit BTUH Stages Used With

460/3/606.0 (B) 20,500 1 THC033-063A4

12.0 (E) 41,000 2 THC033-063A417.6 (G) 59,400 2 THC033-063A423.0 (J) 78,500 2 THC063A4

575/3/606.0 (B) 20,500 1 THC033-063AW

12.0 (E) 41,000 2 THC033-063AW17.6 (G) 59,400 2 THC033-063AW23.0 (J) 78,500 2 THC063AW

Precedent™ PackagedCooling Convertible 3-5 Tons13 SEER R-22 (Model Digit Numbers)

Page 159: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PC-40Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Table PC-40-A — Accessory Electric Heaters – Unit with heater is single circuit / single point power entryModel Power kW Nominal No.Number Supply Rating BTUH Stages Used With

BAYHTRR306A 208/240/3/60 4.5/6.0 13,400/20,500 1 THC033-063A3BAYHTRR312A 208/240/3/60 9.0/12.0 30,800/41,000 2 THC033-063A3BAYHTRR318A 208/240/3/60 13.1/17.4 44,600/59,400 2 THC033-063A3BAYHTRR323A 208/240/3/60 17.3/23.0 58,900/78,500 2 THC063A3

BAYHTRR406A 460/3/60 6.0 20,500 1 THC033-063AA4BAYHTRR412A 460/3/60 12.0 41,000 2 THC033-063A4BAYHTRR418A 460/3/60 17.4 59,400 2 THC033-063A4BAYHTRR423A 460/3/60 23.0 78,500 2 THC063A4

BAYHTRRW06A 575/3/60 6.0 20,500 1 THC033-063AWBAYHTRRW12A 575/3/60 12.0 41,000 2 THC033-063AWBAYHTRRW18A 575/3/60 17.4 59,400 2 THC033-063AWBAYHTRRW23A 575/3/60 23.0 78,500 2 THC063AW

Precedent™ Packaged CoolingConvertible 3-5 Tons 13 SEER R-22

Page 160: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PC-41 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Precedent™ Packaged CoolingConvertible 3-5 Tons 13 SEER R-22

1 Kits contain all necessary parts to achieve desiredlevel of enthalpy control.

2 For ReliaTel™ microprocessor controlled unitsonly. Must be factory installed for electromechani-cal controlled units

3 Used for true discharge air sensing in bothheating and cooling.Required for supply airtempering.

4 Lynn Haven Manufacturing has a No-Returnpolicy for this roof curb.

5 For use with ReliaTel™ controlled units only6 Barometric Relief accessory installs in ductwork

for horizontal configuration. For downflowconfiguration, installs in the unit's horizontal returnduct. See Installer's Guide for completeinstructions.

7 Cannot be used in conjunction with factoryinstalled smoke detector.

8 BAYABRD001C is required when ordering fieldinstalled accessories Clogged Filter Switch(BAYDFPS003A), Fan Fail Switch(BAYDFPS004A), Discharge Air Sensing Kit(BAYTUBE004A) or Evaporator Defrost Control(Frostat) (BAYLOAM020B) Ventilation Override Kit(BAYVNOR001B) unless the following options arefactory installed: Frostat, Smoke Detector,Clogged Filter Switch, Fan Failure Switch,Discharge Air Sensing Kit. These factory installedoptions include the ReliaTel™ Options Module.

9 BAYQACB009A adapts Voyager BAYCURB021Bto accept Precedent 3-5 ton unit. BAYQACB010Aadapts Voyager BAYCURB022B to acceptPrecedent unit.

0 For use with electromechanical controlled unitsonly.

q Cannot be used in conjunction with BarometricRelief. Order Economizer without BarometricRelief.

w BAYQACB012A adapts Voyager BAYCURB025Ato accept Precedent 6-10 ton unit.BAYQACB013A adapts Voyager BAYCURB026Ato accept Precedent 6-10 ton unit.BAYQACB011A adapts Voyager BAYCURB022 toaccept Precedent 6-10 ton unit.

e Interface allows a unit with ReliaTel™ Controls tocommunicate with Tracer 100, Tracker, VariTrac II,and is the preferred method of communication toTracer Summit.

r Activated on Power On.t Field installed accessory requires economizer.y The manual outside air damper will ship factory

supplied within the unit, but must be field installed.

Table PC-41-A — AccessoriesModel Number Description Used With

BAYABRD001C ..................... ReliaTel™ Options Module ..................................................... See Note8BAYASCT0010r .................. Anti-Short-Cycle Timer ........................................................... THC033-063A_EBAYBARM010A6 .................. Barometric Relief .................................................................... THC033-063ABAYCCHT010B ..................... Crankcase Heater ................................................................... THC033-063A3BAYCCHT011B ..................... Crankcase Heater ................................................................... THC033-063A4,AWBAYCO2K001B5t ............... CO2 Sensor Kit, Wall Mounted ................................................ THC033-063A_RBAYCO2K003B5t ............... CO2 Sensor Kit, Duct Mounted ............................................... THC033-063A_RBAYCURB042A4 .................. Roof Curb ............................................................................... THC033-063ABAYDFPS003A58 ............... Clogged Filter Switch .............................................................. THC033-063A_RBAYDFPS004A58 ............... Fan Failure Switch .................................................................. THC033-063A_RBAYDMPR051A5 .................. 0-50% Motorized Outside Air Damper .................................... THC033-063A_RBAYDMPR052A0 .................. 0-50% Motorized Outside Air Damper .................................... THC033-063A_EBAYDMPR053By .................. 0-50% Manual Outside Air Damper ........................................ THC033-063ABAYECON085A5 .................. 0-100% Dry Bulb Economizer without Barometric Relief ...... THC033-063A_RBAYECON086A0 .................. 0-100% Dry Bulb Economizer without Barometric Relief ...... THC033-063A_EBAYENTH005A15 ............... Reference Enthalpy Kit ........................................................... BAYECON085ABAYENTH006A15 ............... Comparative Enthalpy Kit ....................................................... BAYECON085ABAYENTH001A ..................... Enthalpy Control (Solid State) ................................................ BAYECON0086ABAYFRST001A50 ................ High Temperature Stat ........................................................... THC033-063A_RBAYGARD036B ..................... Condenser Coil Hail Guard ..................................................... THC033-043ABAYGARD037B ..................... Condenser Coil Hail Guard ..................................................... THC063ABAYHSMT073A ..................... .45 HP Oversized motor kit ..................................................... THC033A3BAYHSMT074A ..................... .45 HP Oversized motor kit ..................................................... THC033A4BAYHSMT075A ..................... .45 HP Oversized motor kit ..................................................... THC033AWBAYHSMT076A ..................... .75 HP Oversized motor kit ..................................................... THC043A3BAYHSMT077A ..................... .75 HP Oversized motor kit ..................................................... THC043A4BAYHSMT078A ..................... .75 HP Oversized motor kit ..................................................... THC043AWBAYHSMT079A ..................... 1.2 HP Oversized motor kit ..................................................... THC063A3BAYHSMT080A ..................... 1.2 HP Oversized motor kit ..................................................... THC063A4BAYHSMT081A ..................... 1.2 HP Oversized motor kit ..................................................... THC063AWBAYICSI003A5e .................. Trane Communications Interface (TCI) .................................. THC033-063A_RBAYLOAM020B258 ............ Evaporator Defrost Control (Frostat) ...................................... THC033-063A_RBAYLTCI002B5 .................... LonTalk® Communications Interface (LCI) ............................. THC033-063A_RBAYQACB009A49 ............... Quick Adapt Roof Curb ........................................................... THC033-063ABAYQACB010A49 ............... Quick Adapt Roof Curb ........................................................... THC033-063ABAYSTAT0235 ..................... Remote Potentiometer ............................................................ BAYECON085ABAYSERV001A5 .................. Selective Resistance Service Tester ...................................... THC033-063A_RBAYSENS016A5 .................. Temperature Sensor ............................................................... THC033-063A_RBAYTUBE005A358 ............ Discharge Air Sensing Kit ....................................................... THC033-063A_RBAYVNOR001B58t ............ Ventilation Override Kit w/ReliaTel™ options module ............ THC033-063A_R

Page 161: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PC-42Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Table PC-42-A — Zone Sensors for ReliaTel™ Controlled UnitsModelNumber Description Used With

BAYMTPL003B Retrofit Wall Cover Plate Kit 7.25" x 6.0" BAYSENS019CBAYMTPL004B Retrofit Wall Cover Plate Kit 4.75" x 4.75" BAYSENS006,008010B,013,014C,017BBAYSENS006B Single Setpoint Manual Changeover THC033-063A_RBAYSENS008B Dual Setpoint Manual or Auto Changeover THC033-063A_RBAYSENS010B Dual Setpoint Man. or Auto Changeover with System

Function Lights THC033-063A_RBAYSENS019C3 Programmable Night Setback w/System Function Lights THC033-063A_RBAYSENS013C1 Room Sensor w/ Override and Cancel Buttons THC033-063A_RBAYSENS014C1 Room Sensor w/ Temp. Adjustment with Override and

Cancel Buttons THC033-063A_RBAYSENS017B Remote Room Sensor BAYSENS006B,008B,010B, & 019CBAYSENS032A8 Dual Thermistor Remote Zone Sensor THC033-063A_RBAYSENS035A8 Digital Display Zone Sensor THC033-063A_RBAYSENS036A7 Wall-Mounted Humidity Zone Sensor THC033-063A,3,4,WRBAYSENS037A7 Duct-Mounted Humidity Zone Sensor THC033-063A,3,4,WR

Table PC-42-B — ThermostatsModelNumber Description Used With

BAY24X042 DPDT Fan and Electric Heat Relay BAYSTAT008,010BAY28X1904 Locking Thermostat Cover for up to 4 units Room ThermostatsBAYSTAT040B2 Programmable Thermostat THC033-063ABAYBASE008A Subbase 1-Stage Heating/Cooling BAYSTAT040BBAYBASE006A Subbase 2-Stage Heating/Cooling BAYSTAT040BBAYSENS033A Remote Wall Sensor BAYSTAT040BBAYSENS034A Remote Duct Sensor BAYSTAT040BBAYSTAT0083 Manual 1-Stage Heating/Cooling THC033-063ABAYSTAT0103 Auto 2-Stage Heating/Cooling THC033-063ATCONT200AN11AA Electronic 1 Htg/1 Clg (Non Prog) THC033-063A

1 Used with Integrated ComfortTM Systems, any unit type. These sensors do not work with TCM. Consult BASD Marketing for them.2 Requires use of BAYBASE006A or BAYBASE008A.3 Requires DPDT Fan and Electric Heat Relay BAY24x042 when using electric heat.4 Do not use with programmable thermostats.5 Specially designed for electric heat applications (instant on fan).6 Use only with electromechanical unit controls.7 For use with Dehumidification (Hot Gas Reheat) Coil Option.8 For use with ReliaTel™ Controls only.*Either standard or high efficiency models

For additional Controls Information:See ReliaTel™ and Micro Control features on PC-35 and PC-36.

Precedent™ Packaged CoolingConvertible 3-5 Tons 13 SEER R-22

Page 162: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PC-43 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Voyager™ PackagedCooling with ReliaTel™ Controls12½ through 25 Tons

• Colored and numbered wiring• Quick-adjust idler arm pulley. Adjust belt

tension, change belts, adjust airflow quickly(12½ – 25 tons)

• 5-year limited compressor warranty(12½ – 17½ tons)

• 1-year limited compressor warranty(20 and 25 tons)

• 1-year limited parts warranty

12½-25 Ton TCD — Downflow• Meets ASHRAE 90.1-1999• ReliaTel™ control features are listed on

page PC-35• Built-in anti-short cycle, time-delay relay

and minimum on time controls• 2" standard for 12½ – 25 ton units• Liquid line drier• Built-in fork lift holes

• Operating charge of R-22• “Quick Access” on 12½ – 25• Scroll compressors on all units• IAQ sloped condensate drain pans• Dedicated horizontal and downflow units• Single point power for electric heat• Complete line of optional electric heaters• Internally enhanced coil tubing• Low ambient to 0°F standard

Table PC-43-A — TCD Downflow — Micro Control UnitUnit Power Supply Performance Cooling Dimensions (in.) Shipping Max Fuse Size or55555 Downflow

Tons Model No. Volts/Phase/Hz EER (3Ø) Capacity (Btuh) H x W x L Weight (Ibs.) MCA* Max Circuit Breaker* Roofcurb

121/2 TCD150D300B 208-230/3/60 9.8 150,000 50 x 72 x 108 1687 63 80 BAYCURB026B121/2 TCD151C300B 208-230/3/60 11.3 154,000 501/8 x 715/16 x 1075/16 1776 64 80 BAYCURB026B15 TCD180B300H 208-230/3/60 9.9 182,000 50 x 72 x 108 1866 78 90 BAYCURB026B15 TCD181C300C4 208-230/3/60 11.5 189,000 54 x 855/16 x 1225/16 2297 74 90 BAYCURB027B171/2 TCD210C300E 208-230/3/60 9.8 210,000 50 x 72 x 108 2202 88 110 BAYCURB026B171/2 TCD211C300C 208-230/3/60 11.0 220,000 54 x 855/16 x 1225/16 2372 91 110 BAYCURB027B20 TCD240B300J 208-230/3/60 9.7 242,000 54 x 86 x 123 2772 100 125 BAYCURB027B20 TCD241C300C 208-230/3/60 10.6 268,000 54 x 855/16 x 1225/16 2470 99 125 BAYCURB027B25 TCD300B300H 208-230/3/60 9.7 290,000 54 x 855/16 x 1225/16 2365 118 150 BAYCURB027B25 TCD301C300C 208-230/3/60 10.4 300,000 54 x 855/16 x 1225/16 2475 120 150 BAYCURB027B

121/2 TCD150D400B 460/3/60 9.8 150,000 50 x 72 x 108 1687 33 40 BAYCURB026B121/2 TCD151C400B 460/3/60 11.3 154,000 501/8 x 715/16 x 1075/16 1776 31 40 BAYCURB026B15 TCD180B400H 460/3/60 9.9 182,000 50 x 72 x 108 1866 39 50 BAYCURB026B15 TCD181C400C4 460/3/60 11.5 189,000 54 x 855/16 x 1225/16 2292 36 50 BAYCURB027B171/2 TCD210C400E 460/3/60 9.8 210,000 50 x 72 x 108 2202 44 50 BAYCURB026B171/2 TCD211C400C 460/3/60 11.0 220,000 54 x 855/16 x 1225/16 2380 44 60 BAYCURB027B20 TCD240B400J 460/3/60 9.7 242,000 54 x 86 x 123 2372 50 60 BAYCURB027B20 TCD241C400C 460/3/60 10.6 268,000 54 x 855/16 x 1225/16 2470 50 60 BAYCURB027B25 TCD300B400H 460/3/60 9.7 290,000 54 x 855/16 x 1225/16 2365 58 70 BAYCURB027B25 TCD301C400C 460/3/60 10.4 300,000 54 x 855/16 x 1225/16 2475 58 70 BAYCURB027B

121/2 TCD150DW00B 575/3/60 9.8 150,000 50 x 72 x 108 1687 26 30 BAYCURB026B121/2 TCD151CW00B 575/3/60 11.3 154,000 501/8 x 715/16 x 1075/16 1776 25 30 BAYCURB026B15 TCD180BW00H 575/3/60 9.9 182,000 50 x 72 x 108 1866 31 40 BAYCURB026B15 TCD181CW00C4 575/3/60 11.5 189,000 54 x 855/16 x 1225/16 2297 29 40 BAYCURB027B171/2 TCD210CW00E 575/3/60 9.8 210,000 50 x 72 x 108 2702 35 45 BAYCURB026B171/2 TCD211CW00C 575/3/60 11.0 220,000 54 x 855/16 x 1225/16 2380 35 45 BAYCURB027B20 TCD240BW00J 575/3/60 9.7 242,000 54 x 86 x 123 2372 40 45 BAYCURB027B20 TCD241CW00C 575/3/60 10.6 268,000 54 x 855/16 x 1225/16 2470 40 50 BAYCURB027B25 TCD300BW00H 575/3/60 9.7 290,000 54 x 855/16 x 1225/16 2365 46 50 BAYCURB027B25 TCD301CW00C 575/3/60 10.4 300,000 54 x 855/16 x 1225/16 2475 47 60 BAYCURB027B

Supply Return Curb Size Roof OpeningModel No. Downflow W x L1212121212 Downflow W x L1212121212 H x W x L1313131313 W x L1212121212

TC❋150, 151, 180, 210 289/16 x 551/2 207/8 x 63 141/16 x 6615/16 x 1021/4 621/2 x 731/2TC❋181, 211-301 289/16 x 691/2 221/4 x 77 141/16 x 8015/16 x 1171/8 761/2 x 81

MCA = Minimum Circuit Ampacity.Maximum Fuse = Maximum Fuse Size or Maximum HACR Type Circuit Breaker Size.1 Dimensions are in inches. See Outline Dimensions.2 Interior Dimension.3 Measurement Includes Curb Flange.4 Uses 17½ – 25 ton dimensions.5 HACR type circuit breaker per NEC.* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.

Page 163: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PC-44Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Voyager™ PackagedCooling with ReliaTel™ Controls12½ through 25 Tons

• Colored and numbered wiring• Quick-adjust idler arm pulley. Adjust belt

tension, change belts, adjust airflow quickly(12½ – 25 tons)

• 5-year limited compressor warranty(12½ – 17½ tons)

• 1-year limited compressor warranty(20 and 25 tons)

• 1-year limited parts warranty

12½-25 Ton TCH — Horizontal• Meets ASHRAE 90.1-1999• Reliatel™ control features are listed on

page PC-35• Built-in anti-short cycle, time-delay relay

and minimum on time controls• 2" filters for 12½ – 25 ton units• Liquid line drier• Built-in fork lift holes

• Operating charge of R-22• “Quick Access” on 12½ – 25• Scroll compressors on all units• IAQ sloped drain pans• Dedicated horizontal and downflow units• Single point power for electric heat• Complete line of optional electric heaters• Internally enhanced coil tubing• Low ambient to 0°F standard

Table PC-44-A — TCH Horizontal — Micro Control UnitUnit Power Supply Performance Cooling Dimensions (in.) Shipping Max Fuse Size or44444

Tons Model No. Volts/Phase/Hz EER (3Ø) Capacity (Btuh) H x W x L Weight (Ibs.) MCA* Max Circuit Breaker*

121/2 TCH150D300B 208-230/3/60 9.8 150,000 50 x 72 x 108 1687 63 80121/2 TCH151C300C 208-230/3/60 11.3 154,000 50 x 72 x 108 1776 64 8015 TCH180B300H 208-230/3/60 9.9 182,000 50 x 72 x 108 1866 78 9015 TCH181C300C3 208-230/3/60 11.5 189,000 54 x 86 x 123 2297 74 100171/2 TCH210C300E 208-230/3/60 9.8 210,000 50 x 72 x 108 2202 88 100171/2 TCH211C300C 208-230/3/60 11.0 220,000 54 x 86 x 123 2380 91 11020 TCH240B300J 208-230/3/60 9.7 242,000 54 x 86 x 123 2372 100 12520 TCH241C300C 208-230/3/60 10.6 268,000 54 x 86 x 123 2470 99 12525 TCH300B300H 208-230/3/60 9.7 290,000 54 x 86 x 123 2365 118 15025 TCH301C300C 208-230/3/60 10.4 300,000 54 x 86 x 123 2475 120 150

121/2 TCH150D400B 460/3/60 9.8 150,000 50 x 72 x 108 1687 33 40121/2 TCH151C400C 460/3/60 11.3 154,000 50 x 72 x 108 1776 31 4015 TCH180B400H 460/3/60 9.9 182,000 50 x 72 x 108 1866 39 5015 TCH181C400C3 460/3/60 11.5 189,000 54 x 86 x 123 2292 36 50171/2 TCH210C400E 460/3/60 9.8 210,000 50 x 72 x 108 2202 44 50171/2 TCH211C400C 460/3/60 11.0 220,000 54 x 86 x 123 2380 44 6020 TCH240B400J 460/3/60 9.7 242,000 54 x 86 x 123 2372 50 6020 TCH241C400C 460/3/60 10.6 268,000 54 x 86 x 123 2470 50 6025 TCH300B400H 460/3/60 9.7 290,000 54 x 86 x 123 2365 58 7025 TCH301C400C 460/3/60 10.4 300,000 54 x 86 x 123 2475 58 70

121/2 TCH150DW00B 575/3/60 9.8 150,000 50 x 72 x 108 1687 26 30121/2 TCH151CW00C 575/3/60 11.3 154,000 50 x 72 x 108 1776 25 3015 TCH180BW00H 575/3/60 9.9 182,000 50 x 72 x 108 1866 31 4015 TCH181CW00C3 575/3/60 11.5 189,000 54 x 86 x 123 2297 29 40171/2 TCH210CW00E 575/3/60 9.8 210,000 50 x 72 x 108 2202 35 45171/2 TCH211CW00C 575/3/60 11.0 220,000 54 x 86 x 123 2380 35 4520 TCH240BW00J 575/3/60 9.7 242,000 54 x 86 x 123 2372 40 4520 TCH241CW00C 575/3/60 10.6 268,000 54 x 86 x 123 2470 40 5025 TCH300BW00H 575/3/60 9.7 290,000 54 x 86 x 123 2365 46 5025 TCH301CW00C 575/3/60 10.4 300,000 54 x 86 x 123 2475 47 60

Supply ReturnModel No. Horizontal H x W1212121212 Horizontal H x W1212121212

TC❋ 150,151, 180, 210 421/2 x 261/2 421/2 x 249/16

TC❋181, 211-301 467/16 x 261/2 467/16 x 279/16

MCA = Minimum Circuit Ampacity.Maximum Fuse = Maximum Fuse Size or Maximum HACR Type Circuit Breaker Size.1 Dimensions are in inches. See Outline Dimensions.2 Interior Dimension.3 Uses 17½ – 25 ton dimensions.4 HACR type circuit breaker per NEC.* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.

Page 164: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PC-45 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Voyager™ PackagedCooling with ReliaTel™ Controls12½ through 25 Tons

Table PC-45-A — Factory Installed Accessories1212121212 For Complete list of all Factory Installed Options, please refer to the FIOPSsection of this book.Digit Description Order Number Used With

1-9 Main Assembly (see previous page)10 Factory Installed Options

No Options 0 TC*150-301Downflow Economizer3 A TCD150-301Oversized Motor B TC*150-241Downflow Economizer and Oversized Motor3 C TCD150-241Trane Communications Interface (TCI)4 F TC*150-301Downflow Economizer TCI34 G TCD150-301TXV/Face - Split Evaporator H TCD151, 181, 211, 241, 301Oversized Motor and TXV/Face -Split Evaporator J TCD151, 181, 211, 241Downflow Economizer, Oversized Motor and TXV/Face K TCD151, 181, 211, 241Split Evaporator34

Downflow Economizer with TXV/Face - Split Evaportor3 L TCD151, 181, 211, 241, 301Reheat Coil5 M TCD151, 181, 241Downflow Economizer with Reheat Coil35 N TCD151, 181, 241Oversized Motor and Reheat Coil5 P TCD151, 181, 241Downflow Economizer, Oversized Motor and R TCD151, 181, 241Reheat Coil 35

11-12 Minor Design and Service Sequence **1 Price includes accessory and factory installation.2 Four (4) week shipping approximately.3 Some field set up required.4 TCI is for use with non-VariTrac systems and VariTrac systems.5 All 10th digit model numbers including reheat coil (M,N,P,R) require additional factory installed options; ReliaTel™ Options Module (FIYABRD002B), Frostat

(FIYLOAM023A), and 2" Pleated Filters (FIYPLTD001A, 002A, or 003A refer to FIOPS section for appropriate model number usage). For these or any FactoryInstalled Options not included in 10th digit model number, digits 1-3 must be TFD.

Table PC-45-B — Zone SensorsModel Number Description Used With

BAYSENS006B ......... Single Setpoint Manual Changeover ......................................................... TC*150-301BAYSENS008B ......... Dual Setpoint Manual or Automatic Changeover ...................................... TC*150-301BAYSENS010B ......... Dual Setpoint Manual or Automatic Changeover ...................................... TC*150-301

with System Function LightsBAYSENS019C ........ Programmable Night Setback with System Function Lights ..................... TC*150-301BAYSENS013C1 .... Room Sensor with Override Button ........................................................... TC*150-301BAYSENS014C1 .... Room Sensor with Temperature Adjustment and Override ....................... TC*150-301BAYSENS017B ......... Remote Room Sensor ............................................................................... BAYSENS006B, 008B,

010B and 019CBAYSENS032Ay ..... Dual Thermistor Remote Zone Sensor ...................................................... TC*150-301BAYSENS035Ay ..... Digital Display Zone Sensor ....................................................................... TC*150-301BAYSENS036A ......... Wall-Mounted Humidity Sensor ................................................................. TFD151,181,241 (with Reheat)BAYSENS037A......... Duct-Mounted Humidity Sensor ................................................................ TFD151,181,241 (with Reheat)BAYCLCK001Au ...... Electronic Time Clock for up to 4 units ...................................................... BAYSENS006B,008B, 010BBAYMTPL003B ......... Retrofit Wall Cover Plate Kit (71/4" x 6") ..................................................... BAYSENS019CBAYMTPL004A ........ Retrofit Wall Cover Plate Kit (43/4" x 43/4") ................................................. BAYSENS006B, 008B, 010B, 017B

and 013, 014CFor additional Controls Information:See ReliaTel™ and Micro Control features on PC-35 and PC-36.

Page 165: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PC-46Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Voyager™ Packaged Coolingwith ReliaTel™ Controls12½ through 25 Tons Accessories

Table PC-46-A — Field Installed AccessoriesFor complete list of of All Factory Installed Options refer to FIOPS section of this book.

Model Number Description Used WithBAYABRD002e .......... ReliaTel™ Options Module ........................................................ TCD/TCH150-301BAYCO2K002Brt ..... CO2 Sensor Wall Mounted ......................................................... TC*150-301 w/EconomizerBAYCO2K004Brt ..... CO2 Sensor Duct Mounted ........................................................ TC*150-301 w/EconomizerBAYCURB026B67 .... Downflow Roof Curb (Can not be adapted for horizontal use) ..... TCD150D,151C, 180B, 210CBAYCURB027B67 .... Downflow Roof Curb (Can not be adapted for horizontal use) ..... TCD181C, 211C, 240B, 241C, 300B, 301CBAYDFPS005Awe ..... Clogged Filter Switch ................................................................ TCD/TCH (12½-25 Tons)BAYDFPS006Awe ..... Fan Failure Switch .................................................................... All Economizers and 0-50% Motorized Air DampersBAYDMPR029C .......... 0-25% Manual Outside Air Damper ........................................... TCD/TCH (12½-25 Tons)BAYDMPR057A .......... 0-50% Motorized Outside Air Damper ........................................ TCD/TCH150D, 151C, 180B, 210CBAYDMPR058A .......... 0-50% Motorized Outside Air Damper ........................................ TCD/TCH181C, 211C, 240B, 241C, 300B, 301CBAYECON089Ae ....... Downflow Economizer with Barometric Relief ............................. TCD150D, 151C, 180B, 210CBAYECON090Ae ....... Downflow Economizer with Barometric Relief ............................. TCD181C211C, 240B, 241C, 300B, 301CBAYECON091A .......... Horizontal Economizer .............................................................. TCH151C, 180B, 210CBAYECON092A .......... Horizontal Economizer .............................................................. TCH181C211C, 240B, 241C, 300B, 301CBAYENTH007A12 ..... Reference Enthalpy Kit .............................................................. All BAYECNO089-92ABAYENTH008A123 .. Comparative Enthalpy Kit .......................................................... All BAYECNO089-92ABAYFRST003A0 ........ High Temperature Stat .............................................................. TCD/TCH150DBAYGARD043Be ....... Tool-less Hail Guard .................................................................. TC*150BAYGARD044Be ....... Tool-less Hail Guard .................................................................. T*C151C, 180B, 210CBAYGARD045Ae ....... Tool-less Hail Guard .................................................................. T*C181C, 211C, 241C, 301C, 240BBAYGARD047Ae ....... Tool-less Hail Guard .................................................................. TC*300BBAYHSDR002B4 ....... High Static Drive ....................................................................... TCD/TCH151CBAYHSDR005B4 ....... High Static Drive ....................................................................... TCD/TCH180B, 211C, 241C,TCD/TCH150DBAYHSDR010A4 ....... High Static Drive ....................................................................... TCD/TCH300B, 301CBAYHSDR011A4 ....... High Static Drive ....................................................................... TCD/TCH181CBAYHSMT039B4e .... 5HP Oversized Motor Kit ........................................................... TCD/TCH151C, 180B,150DBAYHSMT040B4e .... 5HP Oversized Motor Kit (575V) ................................................ T*151CW, 180BWBAYHSMT042A4e .... 7-1/2HP Oversized Motor Kit (575V) .......................................... TC*211C, 240B, 241CWBAYHSMT055B4e .... 5HP Oversized Motor Kit ........................................................... TCD/TCH181CBAYHSMT059A5e .... 7-1/2HP Oversized Motor Kit (230V) .......................................... TCD/TCH210CBAYHSMT060A5e .... 7-1/2HP Oversized Motor Kit (460V) .......................................... TCD/TCH210CBAYHSMT061A4e .... 7-1/2HP Oversized Motor Kit (575V) .......................................... TC*210CWBAYHSMT072A4e .... 7-1/2HP Oversized Motor Kit (575V) .......................................... TC*181CWBAYHSMT098A4e .... 7-1/2HP Oversized Motor Kit ..................................................... TC*211,240,241C3BAYHSMT099A4e .... 7-1/2HP Oversized Motor Kit ..................................................... TC*211,240,241C4BAYICSI004Bty ........ Comm 3/4 Trane Communications Interface (TCI) ...................... TC*150-301BAYLOAM023Ae ........ Evaporator Defrost Control Frostat ............................................. TC*150-301BAYLSDR004A5 ....... Low Static Drive ........................................................................ TCD/TCH210CBAYLSDR002A5 ....... Low Static Drive ........................................................................ TCD/TCH300B, 301CBAYLTCI003By .......... LonTalk® Communications Interface (LCI) .................................. TC*150-301BAYPWRX029A .......... Power Exhaust for 230 volt units ................................................ BAYECON089-092ABAYPWRX030A .......... Power Exhaust for 460 volt units ................................................ BAYECON089-092ABAYPWRX031A .......... Power Exhaust for 575 volt units ................................................ TCD150DWBAYSENS016A ........... Temperature Sensor ................................................................. TCD/TCH (12½-25 Tons)BAYSERV001A ........... Selective Resistance Service Tester .......................................... TCD/TCH (12½-25 Tons)BAYSTAT0238 ............ Remote Potentiometer .............................................................. All Economizers and 0-50% Motorized Air DampersBAYTUBE008A9we .. Discharge Air Sensing Kit .......................................................... TCD150D-301BAYTUBE009A9we .. Discharge Air Sensing Kit .......................................................... TCH150D-301BAYVNOR002Bw ...... Ventilation Override Kit ........................................................... TC*150-301 w/ReliaTel™ Options Module1 Kit contains all necessary parts to achieve desired level of Enthalpy Control.2 Reference Enthalpy senses outside temperature/humidity and inside supply air only.3 Comparative Enthalpy senses outside temperature/humidity and inside supply and return air.4 High static drive and oversized motors are mutually exclusive, Do Not Combine.5 Low static drive and oversized motors are mutually exclusive, Do Not Combine.6 Clarksville manufacturing has a no return policy for this roof curb.7 For downflow use only. Can not be adapted for horizontal units.8 Cannot be used with Integrated Comfort™ Systems.9 Used for true discharge air sensing in both heating and cooling models.0 Must be used with either field or factory installed TCI (Trane Communications Interface).q Cannot be used with economizer and motorized outside air damper. For operational characteristics see Accessory IOM.w BAYABRD002B is required when ordering field installed BAYDFPS005A or 006A, BAYTUBE008A or 009A and BAYLOAM023A or BAYVNOR002B.e Field or factory installed option.r Field installed accessory. Requires an economizer.t Interface allows a unit with ReliaTel™ Controls to communicate with Tracer 100, Tracker, VariTrac II, and is the preferred method of communication to Tracer Summit.y With ReliaTel™ controlled units only.

Page 166: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PC-47 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Voyager™ PackagedCooling with ReliaTel™ Controls12½ through 25 Tons

Table PC-47-A — Downflow /Horizontal Supplementary Heaters:Model Power kW Nominal No.Number Supply Rating BTUH Stages Used With

AYDHTRK318A 208/240/3/60 13.5/18.0 46,100/61,400 1 TCD180B,181C,150D3,151C3AYDHTRK336A 208/240/3/60 27.0/36.0 92,200/122,900 2 TCD180B,181C,150D3,151C3AYDHTRK354A 208/240/3/60 40.5/54.0 138,200/184,300 2 TCD180B,181C,150D3,151C3

AYDHTRL418A 460/3/60 18.0 61,400 1 TCD150D, 180B4,181C4,151C4AYDHTRK427A 460/3/60 27.0 92,150 2 TCD181C4AYDHTRK436A 460/3/60 36.0 122,900 2 TCD150D, 180B4,181C4,151C4AYDHTRK454A 460/3/60 54.0 184,300 2 TCD150D, 180B4,181C4,151C4

AYDHTRL336A 208/240/3/60 27.0/36.0 92,200/122,900 2 TCD210-301C3,B3AYDHTRL354A 208/240/3/60 40.5/54.0 138,200/184,300 2 TCD210-301C3,B3AYDHTRK372A 208/240/3/60 54.0/72.0 184,300/245,700 2 TCD211-301C3,B3

AYDHTRL427A 460/3/60 27.0 92,150 2 TCD211-301C4AYDHTRL436A 460/3/60 36.0 122,900 2 TCD210-301C4,B4AYDHTRL454A 460/3/60 54.0 184,300 2 TCD210-301C4,B4AYDHTRK472A 460/3/60 72.0 245,700 2 TCD211-301C4,B4

AYHHTRK318A 208/240/3/60 13.5/18.0 46,100/61,400 1 TCH181C3AYHHTRK336A 208/240/3/60 27.0/36.0 92,200/122,900 2 TCH181C3AYHHTRK354A 208/240/3/60 40.5/54.0 138,200/184,300 2 TCH181C3

AYHHTRM418A 460/3/60 18.0 61,400 1 TCH181C4AYHHTRK436A 460/3/60 36.0 122,900 2 TCH181C4AYHHTRM454A 460/3/60 54.0 184,300 2 TCH181C4

AYHHTRN318A 208/240/3/60 13.5/18.0 46,000/61,400 1 TCH150D3,180B3,151C3AYHHTRP336A 208/240/3/60 27.0/36.0 92,200/122,900 2 TCH150D3,180B3,151C3AYHHTRP354A 208/240/3/60 40.5/54.0 138,200/184,300 2 TCH150D3,180B3,151C3

AYHHTRN418A 460/3/60 18.0 61,400 1 TCH150D, 180B4,151C4AYHHTRP436A 460/3/60 36.0 122,900 2 TCH150D, 180B4,151C4AYHHTRP454A 460/3/60 54.0 184,300 2 TCH150D, 180B4,151C4

AYHHTRQ336A 208/240/3/60 27.0/36.0 92,200/22,900 2 TCH210C3AYHHTRQ354A 208/240/3/60 40.5/54.0 138,200/184,300 2 TCH210C3

AYHHTRQ436A 460/3/60 36.0 122,900 2 TCH210C4AYHHTRQ454A 460/3/60 54.0 184,300 2 TCH210C4

AYHHTRN336A 208/240/3/60 27.0/36.0 92,200/122,900 2 TCH211-301C3,B3AYHHTRN354A 208/240/3/60 40.5/54.0 138,200/184,300 2 TCH211-301C3,B3AYHHTRN372A 208/240/3/60 54.0/72.0 184,300/245,700 2 TCH211-301C3,B3

AYHHTRN436A 460/3/60 36.0 122,900 2 TCH211-301C4,B4AYHHTRN454A 460/3/60 54.0 184,300 2 TCH211-301C4,B4AYHHTRN472A 460/3/60 72.0 245,700 2 TCH211-301C4,B4

Note: Unit with heater is single circuit/single point.

Page 167: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PC-48Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Voyager™ Packaged Coolingwith ReliaTel™ Controls12½ through 25 Tons

Table PC-48-A — Downflow /Horizontal Supplementary Heaters:Model Power kW Nominal No.Number Supply Rating BTUH Stages Used With

AYDHTRKW18A 575/3/60 18.0 61,400 1 TCD150DW,180BW,151CW,181CAYDHTRKW36A 575/3/60 36.0 122,900 2 TCD150DW,180BW,210CW,181C

240-300BW,211-301CW

AYDHTRLW54A 575/3/60 54.0 184,300 2 TCD210CW,240-300B,211-301CWAYDHTRKW72A 575/3/60 72.0 245,700 2 TCD211-301CW

AYDHTRMW36A 575/3/60 36.0 122,900 2 TCD150DW,180BW,210CW181C,240-300BW,211-301CW

AYDHTRMW72A 575/3/60 72.0 245,700 2 TCD240-300BW

AYHHTRMW18A 575/3/60 18.0 61,400 1 TCD181CAYHHTRMW36A 575/3/60 36.0 122,900 2 TCH181CW,211-301CWAYHHTRMW54A 575/3/60 54.0 184,300 2 TCH240-300BW,181C

AYHHTRNW18A 575/3/60 18.0 61,400 1 TCH150DW,180BW,151C,181CAYHHTRNW54A 575/3/60 54.0 184,300 2 TCH240-300BW,211-301CWAYHHTRNW72A 575/3/60 72.0 245,700 2 TCH240-300BW,211-301CW

AYHHTRPW36A 575/3/60 36.0 122,900 2 TCH150DW,180BW,210CW,151CAYHHTRPW54A 575/3/60 54.0 184,300 2 TCH150DW,180BW,151C

AYHHTRQW54A 575/3/60 54.0 184,300 2 TCH210CWAYHHTRKW72A 575/3/60 72.0 245,700 2 TCH211-301CW

Note: Unit with heater is single circuit/single point.

See ReliaTel™ and Micro Control features on PC-35 and PC-36.

Page 168: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PH-1 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Table PH-1-A — 2WCX - XL13c - Convertible Package Heat Pump - R-22Cabinet

Model Shipping Max Sound Dimensions (in.)Number Capacity SEER/EER HSPF Weight MCA Fuse Rating H x W x L2WCX – 208/230/1/602WCX3024A1000A 23,200 13.45/11.80 7.9 453 11.5 20 72 36 x 51 x 432WCX3030A1000A 29,400 13.05/11.00 8.4 454 17.1 25 72 36 x 51 x 432WCX3036A1000A 37,200 13.20/11.00 8.0 468 24.2 40 75 36 x 51 x 432WCX3042A1000A 40,000 13.10/11.20 8.25 529 24.6 40 73 38 x 61 x 462WCX3048A1000A 47,000 13.30/11.30 7.95 553 28.6 45 73 38 x 61 x 462WCX3060A1000A 58,500 13.35/11.25 8.3 623 40.4 60 72 42 x 61 x 46

Table PH-1-B — 4WCX - XL13c - Convertible Package Heat Pump - R-410ACabinet

Model Shipping Max Sound Dimensions (in.)Number Capacity SEER/EER HSPF Weight MCA Fuse Rating H x W x L4WCX – 208/230/1/604WCX3018A1000A 18,600 13.15/11.10 7.7 444 10.6 15 69 36 x 51 x 434WCX3036A1000A 36,200 13.20/11.00 7.75 468 25.5 40 71 36 x 51 x 434WCX3048A1000A 46,000 13.15/10.75 8.25 553 31.1 50 73 38 x 61 x 464WCX3060A1000A 59,500 13.05/10.85 7.85 618 43.3 60 72 40 x 61 x 464WCX – 208/230/3/604WCX3036A3000A 36,200 13.20/11.00 7.75 468 18.2 30 71 36 x 51 x 434WCX3048A3000A 46,600 13.15/10.75 8.25 553 23.6 35 73 38 x 61 x 464WCX3060A3000A 59,500 13.05/10.85 7.85 618 31.5 50 72 40 x 59 x 444WCX– 460/3/604WCX3036A4000A 36,200 13.20/11.00 7.75 468 8.7 15 71 36 x 51 x 434WCX3048A4000A 46,000 13.15/10.75 8.25 553 11.7 15 73 38 x 61 x 464WCX3060A4000A 59,500 13.05/10.85 7.85 618 19.3 25 72 40 x 61 x 46

• Architectual Louvers and Corner Guards fordurable protection and extra safety.

• Appliance Grade Finish durable powder paintbaked on both sides of every panel.

• Weater Beater top contoured and reinforcedfor strength.

• Exclusive Climatuff® high efficiencycompressor

• Aerospace Ducted Outdoor fan for quietoperation

• Composite Vortica® Blower uses lessenergy to provide more air with less sound.

• Side electrical service access for high andlow voltage

• Sloped composite no-rust drain pan• Shipped for horizontal application, easily

convertible to downflow• One electric heater family• Optional filter rack fits inside unit• Low voltage polarized plug for easy electric

heater installation• Heavy gauge steel cabinet with weather

resistant, baked enamel finish• Top discharge fan• Demand defrost control• Refrigerant line filter drier

• Solenoid operated switchover valve• Copper tube, aluminum plate fin Indoor coil• Expansion valve no bleed on outdoor coil• High efficiency outdoor fan motor with

polarized plug• Expansion valve no bleed on indoor coil• Water shed base• UL Listed• Crankcase heater• Direct drive blower 2-speed motor• Compressor internal overload protection• Protected pressure taps for refrigerant

checks• Standard operation to 55°F. as manufac-

tured• Low ambient cooling to 0°F. with

BAYLOAM105A• 10-year limited compressor

warranty, 5-year other parts single phase(Residential Use Only)

• Optional extended warranties

Package Heat PumpConvertible 1½ through 5 Tons

For information on Roof Curbs and Roof Curb Adaptors,please refer to the Accessories/Information Tab.

Page 169: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PH-2Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Package Heat PumpConvertible 1½ through 5 Tons

2/4WCX3018A through 2/4WCX3036A

For information on Roof Curbs andRoof Curb Adaptors, please refer tothe Accessories/Information Tab.

Page 170: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PH-3 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Package Heat PumpConvertible 1½ through 5 Tons

2/4WCX3018A through 2/4WCX3036A

For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.

Page 171: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PH-4Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Package Heat PumpConvertible 1½ through 5 Tons

2/4WCX3042A through 2/4WCX3060A

For information on Roof Curbs andRoof Curb Adaptors, please refer tothe Accessories/Information Tab.

Page 172: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PH-5 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Package Heat PumpConvertible 1½ through 5 Tons

2/4WCX3042A through 2/4WCX3060A

For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.

Page 173: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PH-6Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Table PH-6-A — 2WCC - XB13c - Convertible Package Heat Pump - R-22Cabinet

Model Shipping Max Sound Dimensions (in.)Number Capacity SEER/EER HSPF Weight MCA Fuse Rating H x W x L2WCC– 208/230/1/602WCC3024A1000A 23,000 13.00/11.00 7.7 453 12.5 20 76 36 x 49 x 422WCC3030A1000A 28,000 13.00/11.00 7.7 454 17.1 25 76 36 x 49 x 422WCC3036A1000A 35,000 13.00/11.00 7.7 468 24.2 40 75 36 x 49 x 422WCC3042A1000A 40,000 13.00/11.00 7.7 529 24.6 40 78 38 x 59 x 442WCC3048A1000A 45,500 13.00/11.00 7.7 553 28.6 45 79 38 x 59 x 442WCC3060A1000A 58,000 13.00/11.00 7.7 623 40.4 60 79 42 x 59 x 44

Table PH-6-B — 4WCC - XB13c - Convertible Package Heat Pump - R-410ACabinet

Model Shipping Max Sound Dimensions (in.)Number Capacity SEER/EER HSPF Weight MCA Fuse Rating H x W x L4WCC– 208/230/1/604WCC3018A1000A 18,000 13.00/11.00 7.7 444 10.6 15 74 36 x 49 x 424WCC3036A1000A 35,000 13.00/11.00 7.7 468 25.5 40 75 36 x 49 x 424WCC3048A1000A 45,500 13.00/10.75 7.7 553 31.1 50 80 38 x 59 x 444WCC3060A1000A 58,000 13.00/10.85 7.7 618 43.3 60 79 40 x 59 x 444WCC – 208/230/3/604WCC3036A3000A 35,000 13.00/11.00 7.7 468 18.2 30 75 36 x 49 x 424WCC3048A3000A 45,500 13.00/10.75 7.7 553 23.6 35 80 38 x 59 x 444WCC3060A3000A 58,000 13.00/10.85 7.7 618 31.5 50 79 40 x 59 x 444WCC– 460/3/604WCC3036A4000A 35,000 13.00/11.00 7.7 468 8.7 15 75 36 x 49 x 424WCC3048A4000A 45,500 13.00/10.75 7.7 553 11.7 15 80 38 x 59 x 444WCC3060A4000A 58,000 13.00/10.85 7.7 618 19.3 25 79 40 x 59 x 44

• Climatuff® high efficiencycompressor

• Shipped for horizontal application, easilyconvertible to downflow

• One electric heater family• Optional filter rack fits inside unit• Low voltage polarized plug for easy electric

heater installation• Heavy gauge steel cabinet with weather

resistant, baked enamel finish• Top discharge fan• Demand defrost control• Refrigerant line filter drier• Solenoid operated switchover valve• Copper tube, aluminum plate fin Indoor coil• Expansion valve no bleed on outdoor coil

• High efficiency outdoor fan motorwith polarized plug

• Expansion valve no bleed on indoor coil• Water shed base• UL Listed• Crankcase heater• Direct drive blower 2-speed motor• Compressor internal overload protection• Protected pressure taps for

refrigerant checks• Standard operation to 55°F. as manufac-

tured• Low ambient cooling to 0°F. with

BAYLOAM105A• 5-year limited compressor

warranty, 5-year other parts single phase(Residential Use Only)

• Optional extended warranties

Package Heat PumpConvertible 1½ through 5 Tons

For information on Roof Curbs and Roof Curb Adaptors,please refer to the Accessories/Information Tab.

Page 174: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PH-7 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

2/4WCC3018A through 2/4WCC3036A

Package Heat PumpConvertible 1½ through 5 Tons

For information on Roof Curbs andRoof Curb Adaptors, please refer tothe Accessories/Information Tab.

Page 175: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PH-8Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

2/4WCC3018A through 2/4WCC3036A

Package Heat PumpConvertible 1½ through 5 Tons

For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.

Page 176: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PH-9 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

2/4WCC3042A through 2/4WCC3060A

Package Heat PumpConvertible 1½ through 5 Tons

For information on Roof Curbs andRoof Curb Adaptors, please refer tothe Accessories/Information Tab.

Page 177: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PH-10Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

2/4WCC3042A through 2/4WCC3060A

Package Heat PumpConvertible 1½ through 5 Tons

For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.

Page 178: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PH-11 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Package Heat PumpConvertible 1½ through 5 Tons

2WCX 4WCX 2WCC 4WCCTable PH-11-A — Accessories 2-5 1½-5 2-5 1½-5BAYADAP050A ............... Adapter Curb (Cabinet A/B) .......................................................................... 1½-3 1½-3 1½-3 1½-3BAYADAP051A ............... Adapter Curb (Cabinet C) ............................................................................. 1½-3 1½-3 1½-3 1½-3BAYADAP052A ............... Adapter Curb (Cabinet A/B) .......................................................................... 3½-5 3½-5 3½-5 3½-5BAYADAP053A ............... Adapter Curb (Cabinet C) ............................................................................. 3½-5 3½-5 3½-5 3½-5BAYADAP054A ............... Adapter Curb (Cabinet D) ............................................................................. 3½-5 3½-5 3½-5 3½-5BAYCCHT101A .............. Crankcase Heater (230V) ............................................................................. 2-2½,5 1½ 2-2½,4 1½BAYCCHT102A .............. Crankcase Heater (230V) ............................................................................. 3-3½ 3, 4 3-3½ 3,4BAYCCHT104A .............. Crankcase Heater (460V) ............................................................................. — 5 — 5BAYCOVR112A .............. 12" Duct Shroud (Covers Horizontal Ducts)w ................................................ 3½-5 3½-5 3½-5 3½-5BAYCOVR118A .............. 18" Duct Shroud (Covers Horizontal Ducts)w ................................................ 3½-5 3½-5 3½-5 3½-5BAYCURB050A .............. Flat Roof Curb (Insulated)3 .......................................................................... 1½-3 1½-3 1½-3 1½-3BAYCURB051A .............. Flat Roof Curb (Insulated)3 .......................................................................... 3½-5 3½-5 3½-5 3½-5BAYDMPR101A .............. 2-Position Motorized Damper ........................................................................ 1½-3 1½-3 1½-3 1½-3BAYDMPR102A .............. 2-Position Motorized Damper ........................................................................ 3½-4 3½-4 3½-4 3½-4BAYECON101A .............. Economizer with Barometric Relief12458 .................................................. 1½-3 1½-3 1½-3 1½-3BAYECON102A .............. Economizer with Barometric Relief12458 .................................................. 3½-4 3½-4 3½-4 3½-4BAYECON200A .............. Economizer (Horizontal)1248 ..................................................................... ✔ ✔ ✔ ✔BAYECON201A .............. Economizer (Horizontal)1248 ..................................................................... 3½-5 3½-5 3½-5 3½-5BAYENTH100A .............. Enthalpy Control Kit4 .................................................................................... ✔ ✔ ✔ ✔BAYEXMK001A .............. Extreme Conditions Mounting Kit .................................................................. ✔ ✔ ✔ ✔BAYEXMK002A .............. Extreme Conditions Mounting Kit .................................................................. ✔ ✔ ✔ ✔BAYEXMK003A .............. Extreme Conditions Mounting Kit (Used on Slab Mounts) ............................. ✔ ✔ ✔ ✔BAYFLTR101A ................ 1-2" Filter Frame2 ......................................................................................... 1½-3 1½-3 1½-3 1½-3BAYFLTR201A ................ 1-2" Filter Frame2 ......................................................................................... 3½-4 3½-4 3½-4 3½-4BAYLIFT002B ................. Lifting Lug Kit ............................................................................................... ✔ ✔ ✔ ✔BAYLOAM011A .............. Evaporator Defrost Control Kit ....................................................................... ✔ ✔ ✔ ✔BAYLOAM105A .............. Low Ambient Control Kitq ............................................................................. ✔ ✔ ✔ ✔BAYOSAH001A .............. Manual Fresh Air Damper25 ........................................................................ 1½-3 1½-3 1½-3 1½-3BAYOSAH002A .............. Manual Fresh Air Damper25 ........................................................................ 3½-4 3½-4 3½-4 3½-4BAYQSTK300A .............. Quick Start Kit ............................................................................................... 1 Phase Only 1 Phase Only 1 Phase Only 1 Phase OnlyBAYSQRD001A .............. 16" Round Duct Adapter0 ........................................................................... 1½-3 1½-3 1½-3 1½-3BAYSQRD002A .............. 18" Round Duct Adapter0 ........................................................................... 1½-5 1½-5 1½-5 1½-5BAYUTIL101A ................ Roof Curb Extension Kit ................................................................................ 1½-3 1½-3 1½-3 1½-3BAYUTIL102A ................ Roof Curb Extension Kit ................................................................................ 3½-4 3½-4 3½-4 3½-41 Relay required with economizer on all 2/4WC*3 models.2 Must use filter frame when economizer/fresh air kit is used.3 Ships knocked down.4 Dry bulb control standard with economizer.5 Downflow Only.6 Full perimeter curb for 2/4WC*3018-036A models.7 Full perimeter curb for 2/4WC*3042-060A models.8 2-Stage thermostat provides additional energy savings if simultaneous economizer and compressor operation is expected.9 Do not use with programmable thermostats.0 It is the responsibility of the installing dealer to properly size the ductwork for each specific application.q BAYRLAY005A, required on all heat pump applications.w BAYCOVR112,118A will not cover BAYSQRD002A applications

For information on Roof Curbs and Roof Curb Adaptors,please refer to the Accessories/Information Tab.

Page 179: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PH-12Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Package Heat PumpConvertible 1½ through 5 Tons

Table PH-12-A — Supplementary Heaters – Separate power source /power entry requiredModel ShippingNumber Description Used With WeightBAYHTRV105A 3.76/5.0 kW Heater (208/240V 1PH) 2/4WC*3018-060A1 9BAYHTRV110A 7.50/10.0 kW Heater (208/240V 1PH) 2/4WC*3024-060A1 10BAYHTRV115A 11.27/15.00 kW Heater (208/240V 1PH) 2/4WC*3030-060A1 14BAYHTRV120A 15.0/20.0 kW Heater (208/240V 1PH) 2/4WC*3048-060A1 14BAYHTRV305A 3.76/5.0 kW Heater (208/240V 3PH) 2/4WC*3018-060A3 9BAYHTRV310A 7.50/10.0 kW Heater (208/240V 3PH) 2/4WC*3024-060A3 10BAYHTRV315A 11.27/15.00 kW Heater (208/240V 3PH) 2/4WC*3030-060A3 14BAYHTRV320A 15.00/20.0 kW Heater (208/240V 3PH) 2/4WC*3048-060A3 14BAYHTRV405A 3.76/5.0 kW Heater (460V 3PH) 2/4WC*3018-060A4 9BAYHTRV410A 7.50/10.0 kW Heater (460V 3PH) 2/4WC*3024-060A4 10BAYHTRV415A 11.27/15.00 kW Heater (460V 3PH) 2/4WC*3030-060A4 14

BAYHTRV420A 15.00/20.0 kW Heater (460V 3PH) 2/4WC*3048-060A4 14

Table PH-12-B — Single Power Entry Kit/Heater Matrix:Single Power Heater Unit ShippingEntry Kit11111 Model Model WeightBAYSPEK060A BAYHTRV105A 2WC*3024-048A1 3

4WC*3018-036A1BAYSPEK061A BAYHTRV305A 4WC*3036-060A3 7

BAYHTRV310A 4WC*3036-048A3BAYHTRV405A 4WC*3036-060A4BAYHTRV410A 4WC*3036-060A4BAYHTRV415A 4WC*3036-060A4BAYHTRV420A 4WC*3048-060A4

BAYSPEK062A BAYHTRV105A 4WC*3048-060A1 72WC*3060A1

BAYHTRV110A 2WC*3024-060A14WC*3036-060A1

BAYSPEK063A BAYHTRV115A 2WC*3030-060A1 74WC*3036-060A1

BAYHTRV120A 2WC*3048-060A14WC*3048-060A1

BAYSPEK064A BAYHTRV315A 4WC*3036-060A3 6BAYHTRV320A 4WC*3048-060A3

BAYSPEK065A BAYHTRV310A 4WC*3060A3 71 All necessary fuses are included in kit

For information on Roof Curbs and Roof Curb Adaptors,please refer to the Accessories/Information Tab.

Page 180: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PH-13 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

PHASED OUT

Package Heat PumpConvertible 2 through 5 Tons

WCZ-F – XL 1600WCY-G – XL 1400WCX-G – XL 1200

PHASED OUT

Table PH-13-A — WCZ – XL 1600 Convertible Package Heat PumpCooling Cabinet Supply/Return Supply/Return Shipping

Unit Capacity Dimensions (in.) Downflow Horizontal Weight Max SoundModel No. SEER/EER HSPF (Btuh) H x W x L W x L H x W (Ibs.) MCA* Fuse* Rating Comp.

WCZ – 208-230/1/60WCZ036F100B 15.60/12.00 7.65 36,000 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 588 27.1 40 80 R1/2WCZ060F100B 15.05/10.50 8.10 58,000 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 679 43.5 70 82 R1/2WCZ – 208-230/3/60WCZ036F300B 15.60/12.00 7.65 36,000 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 588 19.6 30 82 R1/2WCZ060F300B 15.05/10.50 8.10 58,000 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 679 30.9 45 82 R1/2

Table PH-13-B — WCY-G – XL 1400 Convertible Package Heat PumpCooling Cabinet Supply/Return Supply/Return Shipping

Unit Capacity Dimensions (in.) Downflow Horizontal Weight Max SoundModel No. SEER/EER HSPF (Btuh) H x W x L W x L H x W (Ibs.) MCA* Fuse* Rating Comp.

WCY – 208-230/1/60WCY024G100B 13.70/11.90 7.90 24,500 29 x 36 x 56 (B) 10 x 171/2 189/16 x 111/16 387 15.8 25 80 R1WCY030G100B 13.50/11.50 7.70 30,000 29 x 36 x 56 (B) 10 x 171/2 189/16 x 111/16 398 21.4 30 80 R2WCY036G100B 13.50/11.55 7.95 37,000 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 468 27.4 40 80 R2WCY042G100B 13.05/11.25 7.80 42,000 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 468 29.6 45 80 R2WCY048G100A 13.75/12.00 7.60 49,000 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 576 38.1 60 84 R2WCY060G100A 13.00/11.35 7.80 60,000 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 574 46.8 60 84 S

Table PH-13-C — WCX – XL 1200 Convertible Package Heat PumpCooling Cabinet Supply/Return Supply/Return Shipping

Unit Capacity Dimensions (in.) Downflow Horizontal Weight Max SoundModel No. SEER/EER HSPF (Btuh) H x W x L W x L H x W (Ibs.) MCA* Fuse* Rating Comp.

WCX – 208-230/1/60WCX024G100B 12.80/11.50 7.60 25,800 29 x 36 x 56 (A) 10 x 171/2 189/16 x 111/16 387 17.1 25 80 R1WCX030G100B 12.30/11.00 7.60 30,500 29 x 36 x 56 (A) 10 x 171/2 189/16 x 111/16 398 20.4 30 80 R2WCX036G100B 12.30/10.90 7.60 38,000 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 468 25.9 40 80 R2WCX042G100B 12.20/10.60 7.90 42,500 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 468 25.9 40 80 R2WCX048G100A 12.00/10.60 7.60 48,000 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 576 37.2 55 84 R2WCX060G100A 12.00/10.70 8.20 58,500 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 576 45.4 70 84 R2WCX – 208-230/3/60WCX036G300B 12.30/10.90 7.60 38,000 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 468 17.9 25 80 R2WCX042G300A 12.10/10.60 7.90 42,500 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 468 18.8 30 80 R2WCX048G300A 12.00/10.60 7.60 48,000 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 576 27.8 40 84 R2WCX060G300A 12.00/10.70 8.20 58,500 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 576 30.1 45 84 R2WCX – 460/3/60WCX036G400B 12.30/10.90 7.60 38,000 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 468 9.7 15 80 R2WCX048G400A 12.00/10.60 7.60 48,000 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 576 12.7 15 84 R2WCX060G400A 12.00/10.70 8.20 58,500 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 576 21.1 30 84 R2

* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.Compressor Types are: R1 = Reciprocating One Cylinder, R2 = Reciprocating Two Cylinder, S = Scroll

For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.

Page 181: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PH-14Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

PHASED OUT

PHASED OUT

Package Heat PumpConvertible 1½ through 5 Tons

WCP – XE 1200WCC – XE 1000

Table PH-14-A — WCP – XE 1200 Convertible Package Heat PumpCooling Cabinet Supply/Return Supply/Return Shipping

Unit Capacity Dimensions (in.) Downflow Horizontal Weight Max SoundModel No. SEER/EER HSPF (Btuh) H x W x L W x L H x W (Ibs.) MCA* Fuse* Rating Comp.

WCP – 208-230/1/60WCP036F100B 12.30/10.9 7.6 38,000 29 x 36 x 62 (C) 10 x 171/2 189/16 x 111/16 468 25.9 40 80 R2WCP048F100A 12.00/10.6 7.6 48,000 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 576 37.2 55 84 R2WCP060F100A 12.00/10.7 8.2 60,000 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 576 45.4 70 84 R2

WCP – 208-230/3/60WCP036F300B 12.30/10.90 7.6 38,000 29 x 36 x 62 (C) 10 x 171/2 189/16 x 111/16 468 17.9 25 80 R2WCP048F300A 12.00/10.60 7.6 48,000 33 x 45 x 64 (D) 14 x 20 211/16 x 151/16 576 27.8 40 84 R2WCP060F300A 12.00/10.70 8.2 60,000 33 x 45 x 64 (D) 14 x 20 211/16 x 151/16 576 30.1 45 84 R2WCP – 460/3/60WCP036F400B 12.30/10.90 7.6 38,000 29 x 36 x 62 (C) 10 x 171/2 189/16 x 111/16 468 9.7 15 80 R2WCP048F400A 12.00/10.60 7.6 48,000 33 x 45 x 64 (D) 14 x 20 211/16 x 151/16 576 12.7 15 84 R2WCP060F400A 12.00/10.70 8.2 60,000 33 x 45 x 64 (D) 14 x 20 211/16 x 151/16 576 17.7 25 84 R2

Table PH-14-B — WCC – XE 1000 Convertible Package Heat PumpCooling Cabinet Supply/Return Supply/Return Shipping

Unit Capacity Dimensions (in.) Downflow Horizontal Weight Max SoundModel No. SEER/EER HSPF (Btuh) H x W x L W x L H x W (Ibs.) MCA* Fuse* Rating Comp.

WCC – 208-230/1/60WCC018F100B 10.00/9.60 6.8 18,000 25 x 36 x 55 (A) 10 x 171/2 189/16 x 111/16 337 17.0 25 80 R1WCC024F100B 10.00/9.40 6.8 23,800 25 x 36 x 55 (A) 10 x 171/2 189/16 x 111/16 337 17.7 25 80 R1WCC030F100B 10.00/9.50 6.8 29,800 29 x 36 x 55 (B) 10 x 171/2 189/16 x 111/16 359 23.4 40 80 R1/2WCC036F100B 10.00/9.50 6.8 36,000 29 x 36 x 55 (B) 10 x 171/2 189/16 x 111/16 383 26.0 40 80 R2WCC042F100B 10.00/9.15 6.8 41,500 29 x 36 x 55 (B) 10 x 171/2 189/16 x 111/16 400 31.2 50 80 R2WCC048F100B 10.00/9.50 6.8 48,000 33 x 45 x 64 (D) 14 x 20 211/16 x 151/16 552 37.2 60 84 R2WCC060F100B 10.009.50 6.8 60,000 33 x 45 x 64 (D) 14 x 20 211/16 x 151/16 547 41.1 60 84 R2

WCC – 208-230/3/60 - LIMITED AVAILABILITY 3 PHASE ONLY, 2006.WCC036F300B 10.00/9.50 6.8 36,000 29 x 36 x 55 (B) 10 x 171/2 189/16 x 111/16 459 19.4 30 80 R2WCC042F300B 10.00/9.15 6.8 41,500 29 x 36 x 55 (B) 10 x 171/2 189/16 x 111/16 400 23 7 40 80 R2WCC048F300B 10.00/9.50 6.8 48,000 33 x 45 x 64 (D) 14 x 20 211/16 x 151/16 552 28.3 40 84 R2WCC060F300B 10.00/9.50 6.8 60,000 33 x 45 x 64 (D) 14 x 20 211/16 x 151/16 547 31.5 45 84 R2WCC – 460/3/60 - LIMITED AVAILABILITY 3 PHASE ONLY, 2006.WCC036F400B 10.00/9.50 6.8 36,000 29 x 36 x 55 (B) 10 x 171/2 189/16 x 111/16 359 10.2 15 80 R2WCC048F400B 10.00/9.50 6.8 48,000 33 x 45 x 64 (D) 14 x 20 211/16 x 151/16 552 13.8 20 84 R2WCC060F400B 10.00/9.50 6.8 60,000 33 x 45 x 64 (D) 14 x 20 211/16 x 151/16 547 16.3 25 84 R2

* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.Note: WCC-F models currently manufactured with sloped drain pans.Compressor Types are: R1 = Reciprocating One Cylinder, R2 = Reciprocating Two Cylinder, S = Scroll

For information on Roof Curbs and Roof Curb Adaptors,please refer to the Accessories/Information Tab.

Page 182: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PH-15 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

PHASED OUT

PHASED OUT

Package Heat PumpConvertible 1½ through 5 Tons

C

BA

E

DD

F

ML

J

K ML

YY

N

X X

PHORIZONTALSUPPLYOPENING DOWNFLOW

SUPPLYOPENING

HORIZONTALRETURN OPENING

DOWNFLOWRETURN OPENING

CONDENSATE DRAIN19 MM (3/4") FEMALE NPT

EG

H

35 MM(1 3/8")

29 MM(1 1/8")

76 MM(3")

EVAPORATOR COIL &BLOWER PANEL

SPACER PANELWCCO42F ONLY

CORNER POST

CONDENSOR COIL

ECONOMIZER/FILTERACCESS PANEL

CENTER OFGRAVITY

SUPPLY &RETURN PANEL

PHASED OUT

For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.

PHASED OUT

Table PH-15-A — WCZ – XL 1600 Dimensional DataModel A B C D E F G H J K L M N P BAYCURB0

WCZ036F 64 36 293/16 189/16 111/16 69/16 111/8 17 181/2 25 171/2 10 3 83/4 33AWCZ060F 651/8 45 333/8 211/16 151/16 415/16 91/8 2115/16 221/4 25 20 14 31/2 85/16 34A

Table PH-15-B — WCY – XL 1400 Dimensional DataModel A B C D E F G H J K L M N P BAYCURB0

WCY024G 561/2 36 293/16 189/16 111/16 69/16 613/16 17 21 253/8 171/2 10 3 47/16 30A, 38AWCY030G 561/2 36 293/16 189/16 111/16 69/16 613/16 17 21 243/8 171/2 10 3 47/16 30A, 38AWCY036G 64 36 291/16 189/16 111/16 69/16 111/8 17 191/4 271/2 171/2 10 3 83/4 30A, 38A, 33AWCY042G 64 36 291/16 189/16 111/16 69/16 111/8 17 191/4 271/2 171/2 10 3 83/4 30A, 38A, 33AWCY048G 651/4 45 333/8 211/16 151/16 415/16 91/8 2115/16 241/4 281/2 20 14 31/2 85/16 30A, 38A, 34A

WCY060G 651/4 45 333/8 211/16 151/16 415/16 91/8 2115/16 241/4 281/2 20 14 31/2 85/16 30A, 38A, 34A

Table PH-15-C — WCX – XL 1200 Dimensional DataModel A B C D E F G H J K L M N P BAYCURB0

WCX024G 561/2 36 293/16 189/16 111/16 69/16 613/16 17 21 253/8 171/2 10 3 47/16 30A, 38AWCX030G 561/2 36 293/16 189/16 111/16 69/16 613/16 17 21 243/8 171/2 10 3 47/16 30A, 38AWCX036G 64 36 291/16 189/16 111/16 69/16 111/8 17 191/4 271/2 171/2 10 3 83/4 30A, 38A, 33AWCX042G 64 36 291/16 189/16 111/16 69/16 111/8 17 191/4 271/2 171/2 10 3 83/4 30A, 38A, 33AWCX048G 651/4 45 333/8 211/16 151/16 415/16 91/8 2115/16 241/4 281/2 20 14 31/2 85/16 30A, 38A, 34AWCX060G 651/4 45 333/8 211/16 151/16 415/16 91/8 2115/16 241/4 281/2 20 14 31/2 85/16 30A, 38A, 34A

Table PH-15-D— WCP – XE 1200 Dimensional DataModel A B C D E F G H J K L M N P BAYCURB0

WCP036F 627/8 36 293/16 189/16 111/16 69/16 111/8 17 191/4 271/2 171/2 10 3 83/4 30A, 38A, 33AWCP048F 643/8 45 331/8 211/16 151/16 415/16 91/8 2115/16 241/4 281/2 20 14 31/2 85/16 30A, 38A, 33AWCP060F 643/8 45 331/8 211/16 151/16 415/16 91/8 2115/16 241/4 281/2 20 14 31/2 85/16 30A, 38A, 34A

Table PH-15-E — WCC – XE 1000 Dimensional Data - LIMITED AVAILABILITY 3 PHASE ONLY, 2006.Model A B C D E F G H J K L M N P BAYCURB0

WCC018F 551/4 36 253/16 189/16 111/16 69/16 613/16 17 201/2 25 171/2 10 3 47/16 30A, 38AWCC024F 551/4 36 253/16 189/16 111/16 69/16 613/16 17 201/2 25 171/2 10 3 47/16 30A, 38AWCC030F 551/4 36 293/16 189/16 111/16 69/16 613/16 17 2013/16 255/16 171/2 10 3 47/16 30A, 38AWCC036F 551/4 36 293/16 189/16 111/16 69/16 613/16 17 19 243/16 171/2 10 3 47/16 30A, 38AWCC042F 551/4 36 293/16 189/16 111/16 69/16 613/16 17 1813/16 24 171/2 10 3 47/16 30A, 38AWCC048F 645/16 45 333/8 211/16 151/16 415/16 91/8 2115/16 243/4 29 20 14 31/2 85/16 30A, 38A, 34AWCC060F 645/16 45 333/8 211/16 151/16 415/16 91/8 2115/16 243/4 29 20 14 31/2 85/16 30A, 38A, 34A

Note: WCC-F models currently manufactured with sloped drain pans.

Page 183: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PH-16Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

PHASED OUT

PHASED OUT

Package Dual Fuel Heat Pump withAuxiliary Gas Heat

Table PH-16-B — AccessoriesModel No. Description Used With

BAYECMT002A Extreme Conditions Mounting Kit (Curb Mount) All DCY ModelsBAYECMT003A Extreme Conditions Mounting Kit (Slab or Rack Mount) All DCY ModelsBAYLPKT022A LP Conversion Kit All DCY ModelsBAYLPSS001A LP Conversion Kit w/stainless burners All DCY Models

Additional Accessories are listed on page PH-19.1 Unit ships standard in high heat configuration. Low-fire operation requires optional BAYLOFR001-007 kit..* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.Compressor Types are: R1 = Reciprocating One Cylinder, R2 = Reciprocating Two Cylinder, S = Scroll

Table PH-16-A — DCY – XL 1200 Convertible Dual Fuel Heat PumpsUnit Cooling Gas Heating Cabinet Supply/Return Supply/Return ShippingModel Capacity Capacity Output SEER/ Dimensions (in.) Downflow Horizontal Weight Max. SoundNo. (Btuh) (Btuh)11111 EER AFUE % HSPF H x W x L W x L H x W (Ibs.) MCA* Fuse* Rating Comp.

DCY – 208-230/1/60DCY024F1L0B 25,800 32 or 38 12.80/11.50 78 7.60 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 446 17.1 25 80 R1DCY030F1M0B 30,400 45 or 57 12.20/11.00 78 7.60 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 471 20.4 30 80 R2DCY036F1H0B 38,000 64 or 80 12.30/10.90 80 7.60 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 486 25.9 40 80 R2DCY048F1H0B 48,000 80 or 98 12.00/10.60 80 7.60 33 x 45 x 65 (D) 20 x 14 211/16 x 151/16 628 37.2 55 84 R2DCY060F1M0A 58,500 80 or 98 12.00/10.70 80 8.20 33 x 45 x 65 (D) 20 x 14 211/16 x 151/16 628 45.4 70 84 R2DCY – 208-230/3/60DCY036F3H0B 38,000 64 or 80 12.00/10.90 80 7.60 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 486 17.9 25 80 R2DCY048F3H0B 49,000 80 or 98 12.00/10.60 80 7.60 33 x 45 x 65 (D) 20 x 14 211/16 x 151/16 628 27.8 40 84 R2DCY060F3M0A 58,500 80 or 98 12.00/10.70 80 8.20 33 x 45 x 65 (D) 20 x 14 211/16 x 151/16 628 30.1 45 84 R2DCY – 460/3/60DCY036F4H0B 38,000 64 or 80 12.00/10.90 80 7.60 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 486 9.7 15 80 R2DCY048F4H0B 49,000 80 or 98 12.00/10.60 80 7.60 33 x 45 x 65 (D) 20 x 14 211/16 x 151/16 628 12.7 15 84 R2DCY060F4M0A 58,500 80 or 98 12.00/10.70 80 8.21 33 x 45 x 65 (D) 20 x 14 211/16 x 151/16 628 21.1 30 84 R2

• Dual firing 20 and 25 MBTUHheat exchangers (optional)

• Top discharge condenser fan• Comfort-RTM enhanced performance on

DCY060F models (1ø and 3ø) only• Demand defrost• Water shed base pan• Liquid line filter-drier• High efficiency outdoor fan motor with

polarized plug• 2-speed (high for cooling, low for heating)

direct-drive blower motor• Internal compressor protection• Protected pressure taps for refrigerant

checks• Standard operations to 55°F as manufac-

tured• Low ambient cooling to 0°F with accessories

BAYLOAM011A

• Climatuff® high efficiency compressor• Shipped for horizontal application,

easily convertible to downflow• Heavy gauge steel cabinet with weather

resistant, powder paint• Attractive coil guard and trim ring• Direct spark (3-try) ignition• Aluminized steel tubular heat exchanger• Optional filter rack fits inside unit• Ball-bearing induced draft combustion

blower• Copper tube, aluminum plate fin coils• Restricted or non-restricted operating mode• Low profile horizontal duct take-offs• One screw convertible to downflow• Built-in downflow duct flanges• Single curb fits all models• Aluminized multi-port-in-shot burner

DCY

For information on Roof Curbs and Roof Curb Adaptors,please refer to the Accessories/Information Tab.

Page 184: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PH-17 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

PH

AS

ED

OU

T

PHAS

ED O

UT

PHAS

ED O

UT

PH

AS

ED

OU

T

Package Heat PumpConvertible 1½ through 5 Tons

DCY WCZ WCY-G WCX-G WCP-F WCC-FTable PH-17-A — Features 2-5 3-5 2-5 2-5 3-5 11/2-5

• Impack Plus™ feature set ............................................................................................ — ✔ ✔ ✔ ✔ —• Climatuff® Compressor (2) .......................................................................................... — ✔ — — — —• Climatuff® Compressor (1) .......................................................................................... ✔ — ✔ ✔ ✔ ✔• Comfort “R”™ mode option .......................................................................................... 5 ✔ ✔ 5 5 —• DuraTuff™ Plate Fin coil ............................................................................................... ✔ ✔ ✔ ✔ ✔ ✔• Coil Sav’RTM coil guard ................................................................................................. ✔ ✔ ✔ ✔ — —• Crankcase heater .......................................................................................................... ✔ ✔ ✔ ✔ ✔ ✔• Deluxe XL Lexan nameplate .......................................................................................... ✔ ✔ ✔ ✔ ✔ —• Demand defrost control with Lite Port/Stored diagnostics ............................................. ✔ ✔ ✔ ✔ ✔ ✔• GE ECM variable speed fan w/potted motor module ..................................................... 5 ✔ ✔ 5 5 —• Horizontal convertible to downflow ................................................................................ ✔ ✔ ✔ ✔ ✔ ✔• Polarized plugs .............................................................................................................. ✔ ✔ ✔ ✔ ✔ ✔• Powder paint .................................................................................................................. ✔ ✔ ✔ ✔ ✔ ✔• Time/temperature defrost .............................................................................................. — — — — — ✔• Two-stage cooling .......................................................................................................... — ✔ — — — —• Two-stage heating .......................................................................................................... — ✔ ✔ — — —• 5-year limited compressor only warranty (Commercial use) .......................................... ✔ ✔ ✔ ✔ ✔ ✔• 5-year limited heat exchanger warranty (Commercial use) ........................................... ✔ — — — — —• 5-year limited compressor and coil warranty (Residential use) ..................................... — — — — — ✔• 5-year limited parts warranty (Residential use) ............................................................. ✔ ✔ ✔ ✔ — —• 5-year limited parts warranty (Residential use) ............................................................. — — — — — ✔• 1-year limited coil and parts warranty (Commercial use) .............................................. ✔ ✔ ✔ ✔ ✔ ✔• 10-year limited compressor and coil warranty (Residential use) ................................... ✔ — — — — —• 10-year limited compressor and outdoor coil warranty (Residential use) ...................... ✔ ✔ ✔ ✔ — —• 20-year heat exchanger warranty (Residential use) ...................................................... ✔ — — — — —

Table PH-17-B — Comfort ControlsBAY28X138A ........... Auto 2-Stage Heating/1-Stage Cooling ............................................. ✔ ✔ ✔ ✔BAY28X153A ........... Auto 3-Stage Heating/2 Stage Cooling ............................................. ✔ ✔ ✔ ✔BAY28X1901 ........ Locking Thermostat Cover ................................................................ ✔ ✔ ✔ ✔BAY41X1711 ........ 5 or 7 Minute Delay Relay ................................................................. ✔ ✔ ✔ ✔BAYASCT001A1 ....... Anti-short Cycle Timer ...................................................................... — — — —BAYSTAT033A ......... Outdoor Thermostat ......................................................................... ✔ ✔ ✔ ✔BAYSTAT040B3 ...... Prog. Electronic Setback 3 Htg/2 Clg ................................................ ✔ — — —BAYSTAT239A ......... Manual 2-Stage Heating/1 Cooling ................................................... ✔ ✔ ✔ ✔BAYSTAT240A ......... Manual 2 Heating/1 Cooling with Subbase ........................................ ✔ ✔ ✔ ✔BAYSTAT253A ......... Humidity Control ............................................................................... — — — —TAYSENS100A ........ Outdoor Temp. Sensor (with case) .................................................... ✔ ✔ ✔ ✔TAYSTAT500C ......... XT 500C Manual Prog. 3 Htg/2 Clg ................................................... ✔ ✔ ✔ ✔TAYSTAT540 ............ Prog.,5/2 Day, Manual ...................................................................... ✔ ✔ ✔ ✔TAYSTAT570 ............ Electronic, 2Htg/1Clg (Non Prog.) ..................................................... ✔ — — —TAYSTAT575 ............ Electronic, 3Htg/2Clg (Non Prog.) ..................................................... ✔ — ✔ ✔TCONT402A ............ 3Htg/2Clg (Heat Pump/A/C) ............................................................. ✔ ✔ ✔ ✔TCONT602A ............ 2Htg/2Clg (Heat Pump/A/C) ............................................................. ✔ ✔ ✔ ✔TCONT802A ............ 3Htg/2Clg (Heat Pump/A/C) ............................................................. ✔ ✔ ✔ ✔TCONT803A ............ 3Htg/2Clg (Heat Pump/A/C) w/Humidity Control ............................... ✔ ✔ ✔ ✔

1 Not for use with programmable thermostats.2 Subbase used with BAYSTAT040B.3 Use with BAYBASE007A.

See

Com

fort

Con

trol

s/ Z

one

Sen

sors

Sec

tion

See

Com

fort

Con

trol

s/ Z

one

Sen

sors

Sec

tion

For information on Roof Curbs and Roof Curb Adaptors,please refer to the Accessories/Information Tab.

Page 185: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PH-18Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Table PH-18-A — Supplementary Heaters – Single Point Entry Kit/Heater MatrixUsed With Single Used With

Model No. Description Power Entry Kit1212121212 Packaged Heat Pump Unit

BAYHTRN105A ... 3.74/4.98 kW Heater (208/240V 1PH) ....... BAYSPEK047A ..... WCC018-042F1, WCY024-042G1, WCX024-042G1,WCZ036F1

BAYHTRN108A ... 5.76/7.68 kW Heater (208/240V 1PH) ....... BAYSPEK047A ..... WCC018-024F1, WCY/WCX024G1BAYSPEK049A ..... WCC030-042F1,WCY030-042G1,WCX030-042G1,

WCZ036F1BAYHTRN110A ... 7.47/9.96 kW Heater (208/240V 1PH) ....... BAYSPEK049A ..... WCC024-048F1, WCY024-048G1 ,WCX024-048G1, WCZ036F1

BAYSPEK053A ..... WCC/WCZ060F1, WCY060G1,WCX060G1BAYHTRN112A ... 8.65/11.52 kW Heater (208/240V 1PH) ..... BAYSPEK049A ..... WCC024-048F1, WCY024-048G1,WCX024-048G1, WCZ036F1

BAYSPEK053A ..... WCC/WCZ060F1,WCY060G1, WCX060G1BAYHTRN115A ... 11.21/14.94 kW Heater (208/240V 1PH) .... BAYSPEK048A ..... WCC030-048F1, WCY030-048G1, WCX030-048G1, WCZ036F1

BAYSPEK052A ..... WCC/WCZ060F1, WCY060G1, WCX060G1BAYHTRN117A ... 12.98/17.28 kW Heater (208/240V 1PH) .... BAYSPEK048A ..... WCC030-048F1, WCY030-048G1, WCX030-048G1, WCZ036F1

BAYSPEK052A ..... WCC/WCZ060F1, WCY060G1, WCX060G1BAYHTRN123A ... 17.2/23.04 kW Heater (208/240V 1PH) ..... BAYSPEK048A ..... WCC048F1, WCY048G1, WCX048G1

BAYSPEK052A ..... WCC/WCZ060F1,WCY/ WCX060G1BAYHTRN306A ... 4.89/6.25 kW Heater (208/240V 3PH) ....... BAYSPEK047A ..... WCC/WCZ036-060F3, WCX036-060G3BAYHTRN310A ... 7.45/9.96 kW Heater (208/240V 3PH) ....... BAYSPEK047A ..... WCC/WCZ036F3, WCP036 - 060F3, WCX036G3

BAYSPEK051A ..... WCZ060F3BAYHTRN310F ... 7.45/9.96 kW Heater (208/240V 3PH) ....... BAYSPEK051A ..... WCZ060F3, WCX/WCY036-060G3, WCP036-060F3

BAYSPEK047 ........ WCZ036F3BAYHTRN315A ... 11.25/14.90 kW Heater (208/240V 3PH) .... BAYSPEK051A ..... WCC/WCZ036-060F3, WCX036-060G3, WCP036-060F3BAYHTRN320A ... 14.96/19.92 kW Heater (208/240V 3PH) .... BAYSPEK051A ..... WCC042-060F3, WCX042-060G3, WCZ060F3,

WCP042-060F3BAYHTRN330A ... 22.41/29.80 kW Heater (208/240V 3PH) .... BAYSPEK050A ..... WCC/WCZ060F3, WCX060G3, WCP060F3BAYHTRN406A ... 6kW Heater (480V 3PH) .......................... BAYSPEK047A ..... WCC/WCP036-060F4, WCX036-060G4BAYHTRN410A ... 9.96 kW Heater (480V 3PH) ..................... BAYSPEK047A ..... WCC036-060F4, WCP036-060F4, WCX036-060G4BAYHTRN410F ... 9.96 kW Heater (460V 3PH) ..................... BAYSPEK047A ..... WCP036-060F4, WCX036-060G4BAYHTRN415A ... 14.90 kW Heater (480V 3PH) ................... BAYSPEK047A ..... WCC036-060F4, WCP036-060F4, WCX036-060G4BAYHTRN420A ... 19.92 kW Heater (480V 3PH) ................... BAYSPEK047A ..... WCC048-060F4, WCP048-060F4, WCX048-060G4BAYHTRN430A ... 29.80 kW Heater (480V 3PH) ................... BAYSPEK047A ..... WCC060F4, WCP060F4, WCX060G4

1 All necessary fuses are included in kit.2 Relay required with economizer on WCZ-F models.

Package Heat PumpConvertible 1½ through 5 Tons

For information on Roof Curbs and Roof Curb Adaptors,please refer to the Accessories/Information Tab.

Page 186: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PH-19 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

PH

AS

ED

OU

T P

HA

SE

D O

UT

PH

AS

ED

OU

T

Package Heat PumpConvertible 1½ through 5 Tons

* Currently Shipped with BAYCURB038A.** Currently Shipped with BAYCURB033A.*** Currently Shipped with BAYCURB034A.

DCY WCZ WCY-G WCX WCP WCCTable PH-19-A — Accessories 2-5 3-5 2-5 2-5 3-5 1½-5BAY24X045 ......... Indoor Fan Delay Kit .................................................................................. — — — 2-5 3-5 11/2-5BAYASCT00168 Anti-Short Cycle Timer ............................................................................... 2-5 3-5 2-5 2-5 3-5 11/2-5BAYCURB030A ... Roof Curb (Flat Roof)3 (14 H x 34 W x 531/8 L) .......................................... 2-5 3-5 2-4 2-5 3-5 11/2-5BAYCURB033A ... Roof Curb (Flat Roof)3 Acousti-Curb (14 H x 34 W x 605/8 L) .................... 2-3 3 3 31/2 31/2 —BAYCURB034A ... Roof Curb (Flat Roof)3Acousti-Curb (14 H x 43 W x 621/16 L) .................... 4-5 5 4-5 4-5 4-5 4-5BAYCURB038A ... Roof Curb (Flat Roof)3 Acousti-Curb (14 H x 34 W x 531/8 L) .................... 2-5 3-5 2-4 2-5 3-5 11/2-5BAYDMPR040A ... 0-25% Manual Fresh Air Damper (Downflow Only)2 ................................ 2-3 3 2-31/2 2-31/2 3 11/2-31/2

BAYDMPR041A ... 0-25% Manual Fresh Air Damper (Downflow Only)2 ................................ 4-5 5 4-5 4-5 4-5 4-5BAYDMPR050A ... Motorized Fresh Air Damper ...................................................................... 4-5 — 4-5 4-5 4-5 4-5BAYDUCT004A ... 12" Round Duct Adapters (2 per Box) ....................................................... 2-3 3 2-31/2 2-31/2 3 11/2-31/2

BAYDUCT005A ... 14" Round Duct Adapters (1 per Box) ....................................................... 2-3 3 2-31/2 2-31/2 3 11/2-31/2

BAYECMT002A ... Extreme Conditions Mounting Kit (Curb Mount) ......................................... 2-5 3-5 2-5 2-5 3-5 11/2-5BAYECMT003A ... Extreme Conditions Mounting Kit (Slab or Rack Mount) ............................. 2-5 3-5 2-5 2-5 3-5 11/2-5BAYECON054B ... 0-100% Mod. Downflow Economizer with Bar Relief1245 ..................... 2-3 3 2-31/2 2-31/2 3 11/2-31/2

BAYECON055B ... 0-100% Mod. Downflow Economizer with Bar Relief1245 ..................... 4-5 5 4 -5 4-5 4-5 4-5BAYECON073A ... 0-100% Mod. Horizontal Economizer1245 ............................................ 2-5 3-5 2-5 2-5 3-5 11/2-5BAYENTH001A ... Enthalpy Control (Solid State)4 ................................................................ 2-5 3-5 2-5 3-5 3-5 11/2-5BAYFLTR012A ..... Filter Frame2 (20 x 25 x 1" filter not included) ........................................... — — 2-21/2 2-21/2 — 21/2-31/2

BAYFLTR013A ..... Filter Frame2 (20 x 25 x 1" filter not included) ........................................... 2-3 3 3-31/2 3-31/2 3 —BAYFLTR014A ..... Filter Frame2 (3-10 x 25 x 1" filter not included) ........................................ 4-5 5 4-5 4-5 4-5 4-5BAYFLTR015A ..... Filter Frame2 (20 x 20 x 1" filter not included) ........................................... — — — — — 11/2-2BAYFLTR017A ..... Filter Frame2 (1-20 x 25 x 2" filter not included) ........................................ — — 2-21/2 2-21/2 — 21/2-31/2

BAYFLTR018A ..... Filter Frame2 (1-20 x 25 x 2" filter not included) ........................................ 2-3 3 3-31/2 3-31/2 3 —BAYFLTR019A ..... Filter Frame2 (2-16 x 25 x 2" filter not included) ........................................ 4-5 5 4 4-5 4-5 4-5BAYGARD016A ... Condenser Coil Guard ............................................................................... — — — — — 11/2-2BAYGARD017A ... Condenser Coil Guard ............................................................................... — — — — — 21/2-3BAYGARD019A ... Condenser Coil Guard ............................................................................... — — — — — 31/2

BAYGARD022A ... Condenser Coil Guard ............................................................................... — — — — — 4-5BAYHSMT043A ... High Static Motor (230/460) 3/4HP ............................................................ 21/2-3 — — 21/2-31/2 21/2-3 21/2-31/2

BAYHSMT044A ... High Static Motor (230/460) 1HP ............................................................... 4 — — 4 4 4-5BAYHSMT045A ... High Static Motor (208) 1HP ...................................................................... 4 — — 4 4 4-5BAYHSMT056A ... High Static Motor (208) 3/4HP ................................................................... 21/2-3 — — 21/2-31/2 3 21/2-31/2

BAYINDK001A* ... Insulated Deck Pan for A & B Cabinet ........................................................ — — 2-21/2 2-21/2 — 11/2-3BAYINDK002A** .. Insulated Deck Pan for C Cabinet .............................................................. 2-3 3 3-31/2 3-31/2 3 —BAYINDK003A*** . Insulated Deck Pan for D Cabinet .............................................................. 4-5 5 4-5 4-5 4-5 4-5BAYKSKT010A .... Quick Start Kit (Single Phase Units Only) ................................................. — — — — — 11/2-5BAYLIFT002B ...... Lifting Lug Kit ............................................................................................ 2-5 3-5 2-5 2-5 3-5 11/2-5BAYLOAM011A ... Evaporator Defrost Control Kit ................................................................... 2-5 3-5 2-5 2-5 3-5 11/2-5BAYLOAM323A ... Dual Voltage Electronic Head Pressure Control7 (use w/BAYRLAY005) ........... 2-5 — 2-5 2-5 3-5 11/2-5BAYLOFR001 ...... Low Fire Kit ................................................................................................ 2 — — — — —BAYLOFR004 ...... Low Fire Kit ................................................................................................ 21/2 -3 — — — — —BAYLOFR005 ...... Low Fire Kit ................................................................................................ 3 — — — — —BAYLOFR007 ...... Low Fire Kit ................................................................................................ 4-5 — — — — —BAYLPKT022A .... LP Conversion Kit ...................................................................................... 2-5 — — — — —BAYLPSS001A .... LP Conversion Kit with SS Burners ............................................................ 2-5 — — — — —BAYMOTR307A ... 200-230V 1/2HP OD Fan Motor (use w/BAYLOAM323A&BAYRLAY005) .......... 2-5 — 2-5 2-5 3-5 11/2-5BAYMOTR406A ... 460V 1/2HP Outdoor Fan Motor (use w/BAYLOAM323A&BAYRLAY005) ......... 3-5 — — 3-5 3-5 3-5BAYOSAC001A ... Outside Air Controller ............................................................................. — 3-5 — — — —BAYRLAY002 ....... Time Delay Relay ..................................................................................... — — 2-5 2-5 2-5 —BAYRLAY004A .... Economizer Relay Kit1 ............................................................................. 2-5 3-5 2-5 2-5 3-5 11/2-5BAYRLAY005A7 . Relay Required with BAYLOAM323A8 ...................................................... 2-5 — 2-5 2-5 3-5 11/2-5BAYSTAT023 ....... Remote Potentiometer for All Economizers ................................................ 2-5 3-5 2-5 2-5 3-5 11/2-5BAYUTIL030A ..... Roof Curb Utility Extension Kit for BAYCURB030, 038A ............................ — — — — — 11/2-5BAYUTIL034A ..... Roof Curb Utility Extension Kit for BAYCURB034A .................................... — — — — — 4-5

1 BAYRLAY004A required with economizer.2 Must use filter frame when economizer/fresh air kit is used.3 Ships knocked down.4 Dry bulb control standard with economizer.5 2-Stage thermostat provides additional energy savings if simultaneous

economizer and compressor operation is expected.6 Do not use with programmable thermostats.7 May require motor change. (See Installers Guide.)8 Activated on Power On.

For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.

Page 187: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PH-20Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Table PC-20-A — XE 1200 — Cooling w/5/10-15 kW Electric Heat - Single Phase (208/230/1/60)Cooling Dimensions Round Round Shipping

Unit Capacity (in.) Supply Return Weight SoundTons Model No. SEER/EER (Btuh) H x W x L Opening Opening (Ibs.) Rating Compressor

2 WCK024A100A 12.50/11.00 25,000 31 x 32 x 44 (**) 14" 14" 348 73 R121/2 WCK030A100A 12.30/10.75 30,500 31 x 32 x 44 (**) 14" 14" 350 73 S3 WCK036A100A 12.75/10.70 36,000 31 x 32 x 44 (**) 14" 14" 370 73 S31/2 WCK042A100A 12.00/10.50 42,000 31 x 32 x 44 (**) 14" 14" 372 73 S

WCK• Climatuff® compressor• Compressor motor overload protection• Internal pressure relief valve• Demand Defrost Control w/Lite Port/Stored

Diagnostics• Copper tube, aluminum plate fin coils• Static (0.5") ESP Indoor Blower System with

two-speed blower motor• Shaft-Down OD fan system for quiet operation

(good neighbor)

• Sloped composite drain pan• Waterproof closed-cell foam evaporator base

insulation• Heavy gauge steel cabinet• Weather resistant Powder Paint• Double powder painted G90 base pan with

dimpled feet• Wrap-around vinyl-coated wire coil guards• U.L. listed• 5-year limited warranty on compressor and

5-year on all other parts (Residential use)• Optional extended warranties

Package Heat Pump2 through 3½ Tons

Table PC-20-B — Electric Heater DataUSING SINGLE SUPPLY CIRCUIT HEATER ONLY

WCK HEAT PUMP SUPPLY CIRCUITMax. Fuse Canda Max. Fuse Canda

Unit Electric Rated Heater or HQCR Only Max. or HQCR Only Max.Model Heater Voltage Kw MCA (2) CKT BKR CKT BKR MCA (7) CKT BKR CKT BKRModel 208/240 Size (4) Size (5) Size (4) Size (5)

NONE** 208/240 NONE** 17/17(3) 25/25 25/25 NONE NONE NONEWCK024A1 (6) BAYHTRK105A 208/240 3.74/4.98 40/43(3) 45/45 50/50 23/26 25/30 25/30

BAYHTRK111A 208/240 7.47/9.96 62/70(3) 70/70 70/70 45/53 45/60 50/60NONE** 208/240 NONE** 21/21(3) 30/30 30/30 NONE NONE NONE

WCK030A1 (6) BAYHTRK105A 208/240 3.74/4.98 44/47(3) 50/50 50/50 23/26 25/30 25/30BAYHTRK110A 208/240 7.47/9.96 66/73(3) 70/80 70/100 45/53 45/60 50/60

NONE** 208/240 NONE** 25/25(3) 40/40 40/40 NONE NONE NONE

WCK036A1 (6) BAYHTRK105A 208/240 3.74/4.98 48/51(3) 50/60 50/60 23/26 25/30 25/30BAYHTRK110A 208/240 7.47/9.96 70/77(3) 70/80 70/100 45/53 45/60 50/60BAYHTRK115A 208/240 11.18/14.94 93/103(3) 100/110 100/110 58/78 70/80 70/100

NONE** 208/240 NONE** 28/28(3) 45/45 45/45 NONE NONE NONE

WCK042A1 (6) BAYHTRK105A 208/240 3.74/4.98 51/54(3) 60/60 60/60 23/26 25/30 25/30BAYHTRK110A 208/240 7.47/9.96 73/80(3) 80/80 100/100 45/53 45/60 50/60BAYHTRK115A 208/240 11.18/14.94 96/106(3) 100/110 100/125 68/78 70/80 70/100

** Unit electrical information with no electric heat installed.1. Any power supply and circuits must be wired and protected in

accordance with local electrical codes.2. The MCA values listed are for electric heater and heat pump unit.

3. Field wire must be rated at least 75°C.4. The HACR circuit breaker is for U.S.A. installations only.5. For Canada installation reference only.6. BAYHTR111A only approved for WCK024A1.7. The MCA values listed are for electric heater only.

Table PC-20-C — Accessories/Comfort ControlsModel No. Description Used With

BAY28X1842 Subbase Auto/Man. Changeover BAY28X183BAY28X1853 Subbase Man. Changeover BAY28X182,183BAY28X1872 Subbase Auto Changeover BAY28X182,183BAYECMT002A Extreme Conditions Mounting Kit (Curb Mount) All WCK ModelsBAYECMT003A Extreme Conditions Mounting Kit (Slab or Rack Mount) All WCK ModelsBAYCOVR100A Wallcover Plate TAYSTAT371TAYSENS100A Outdoor Temperature Sensor (with case) TAYSTAT300TCONT402A 3Heat/2Clg (Heat Pump/A/C) All WCK ModelsTCONT602A 2Heat/2Clg (Heat Pump/A/C) All WCK ModelsTCONT802A 3Heat/2Clg (Heat Pump/A/C) All WCK ModelsTCONT803A 3Heat/2Clg (Heat Pump/A/C) w/Humidity Control All WCK Models

A/M = Automatic or Manual Changeover1 Requires subbase.2 Requires BAY24X042 relay when used with electric heaters.3 Specially designed for electric heater application (instant on fan).* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.

WCK models will be upgraded in the 1st Quarter of 2006.

For information on Roof Curbs andRoof Curb Adaptors, please refer tothe Accessories/Information Tab.

Page 188: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PH-21 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

• Climatuff® compressor• Over(Supply)/Under (Return) air configuration• Electric heat accessory fits inside unit casing

for lower installation cost• Electronic time/temperature defrost control

system• Demand Defrost Control w/Lite Port/stored

diagnostics

WCH

Package Heat PumpOver/Under 2 through 5 Tons

RIGHT SIDE

422mm[16-5/8]

LEFT SIDE

311mm[12-1/4]

• Powder paint• Top discharge – quieter operation• 5-year limited compressor warranty• 5-year limited coil and parts warranty• Variable speed direct drive blower motor on

WCH048-060F models

Table PH-21-A — WCH – Over/Under Horizontal UnitUnit Power Supply Nom. Cap. Dimensions ShippingModel Volts/ Cooling (in.) Weight Max SoundNo. Phase/Hz SEER/EER HSPF (Btuh) H x W x L (lbs.) MCA* Fuse* Rating Comp.Single PhaseWCH024B100C 208-230/1/60 12.40/10.80 8.0 24,500 303/8 x 315/8 x 44 324 17.2 25 79 R1WCH030B100C 208-230/1/60 12.05/10.80 7.7 30,500 303/8 x 315/8 x 44 343 19.3 30 79 R2WCH036B100C 208-230/1/60 12.05/10.50 8.0 36,400 303/8 x 315/8 x 44 378 25.1 40 79 R2WCH042B100C 208-230/1/60 12.05/10.70 8.0 40,500 303/8 x 315/8 x 44 378 25.1 40 79 R2WCH048F100A 208-230/1/60 13.50/12.00 8.0 49,000 331/8 x 45 x 58 447 37 50 84 SWCH060F100A 208-230/1/60 13.00/11.30 8.2 60,000 331/8 x 45 x 58 457 47 60 84 S

Tons Supply H x W Return H x W

2 – 31/2 83/8 x 273/8 163/4 x 273/84 – 5 81/2 x321/32 1915/16 x 321/32

Table PH-21-B — WCH – Over/Under Horizontal UnitUnit Power Supply Nom. Cap. Dimensions ShippingModel Volts/ Cooling (in.) Weight Max SoundNo. Phase/Hz SEER/EER HSPF (Btuh) H x W x L (lbs.) MCA* Fuse* Rating Comp.Three PhaseWCH036B300C 208-230/3/60 12.05/10.50 7.4 36,000 303/8 x 315/8 x 44 378 17.8 25 82 R2WCH042B300C 208-230/3/60 12.05/10.70 7.5 41,000 303/8 x 315/8 x 44 378 19.4 30 82 R2

WCH036B400C 460/3/60 12.05/10.50 7.4 36,000 303/8 x 315/8 x 44 378 9.7 15 82 R2WCH042B400C 460/3/60 12.05/10.70 7.5 41,000 303/8 x 315/8 x 44 378 10.7 15 82 R2

Tons Supply H x W Return H x W

3 – 31/2 83/8 x 273/8 163/4 x 273/8Dimensions are in inches. See Outline Dimensions.* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.Compressor Types are: R1 = Reciprocating One Cylinder, R2 = Reciprocating Two Cylinder, S = Scroll

WCH models will be upgraded inthe 1st Quarter of 2006.

For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.

Page 189: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PH-22Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Package Heat PumpOver/Under 2 through 5 Tons

Table PH-22-B — Accessories/Comfort ControlsModel No. Description Used With

BAY28X138A ....................... 2-Stg. Heat/1-Stg. Cool Auto. Thermostat ..........................................All WCH ModelsBAY28X153A ....................... Auto. 3 Stg. Htg./2 Stg Clg. ................................................................All WCH ModelsBAYASCT00114 ............... Anti-Short Cycle Timer ......................................................................All WCH ModelsBAYBASE007A3 ............... 3-Heat/2-Cool Heat Pump .................................................................BAYSTAT040BBAYECMT002A ................... Extreme Conditions Mounting Kit (Curb Mount) ................................All WCH ModelsBAYECMT003A ................... Extreme Conditions Mounting Kit (Slab or Rack Mount) ....................All WCH ModelsBAYLOAM011A ................... Low Ambient Cooling Kit ...................................................................All WCH ModelsBAYSTAT033A ..................... Outdoor Thermostat ..........................................................................All WCH ModelsBAYSTAT040B ..................... Programmable (used with BAYBASE) ...............................................All WCH ModelsBAYSTAT239A ..................... 2-Stg. Heat/1-Stg. Cool Manual Thermostat ......................................All WCH ModelsBAYSTAT240A ..................... Manual 2 Heat/1 Cool with Subbase .................................................All WCH ModelsTAYASCT501A4 ................. 5 minute delay relay ..........................................................................All WCH ModelsTAYSENS100A .................... Outdoor Temp. Sensor .......................................................................TAYSTAT500CTAYSTAT500C ..................... XT500C Prog.,7 Day, Man/Auto ........................................................All WCH ModelsTAYSTAT540 ....................... Prog.,5/2 Day, Manual .......................................................................All WCH ModelsTAYSTAT570 ....................... Electronic, 2Htg/1Clg (Non Prog.) .....................................................All WCH ModelsTCONT402A ........................ 3Heat/2Clg (Heat Pump/A/C) ............................................................All WCH ModelsTCONT602A ........................ 2Heat/2Clg (Heat Pump/A/C) ............................................................All WCH ModelsTCONT802A ........................ 3Heat/2Clg (Heat Pump/A/C) ............................................................All WCH ModelsTCONT803A ........................ 3Heat/2Clg (Heat Pump/A/C) w/Humidity Control .............................All WCH Models

1 Not for use with programmable thermostats.2 BAYSENS026A must be used with BAYSENS025A.3 Subbase used with BAYSTAT040B.4 Activated on Power Off.* Heaters must have an “A” in eleventh digit to work on WCH models.

Table PH-22-A— Supplementary Heaters – Heater MatrixModel No. Power Supply kW Ratings Used With

BAYHTRC106A 208/240/1/60 4.33/5.76 kW WCH024-042B100B, 048F1, 060F1BAYHTRC108A 208/240/1/60 6.12/8.16 kW WCH024-042B100BBAYHTRC110A 208/240/1/60 7.93/10.56 kW WCH048F1 onlyBAYHTRC111A 208/240/1/60 7.98/10.56 kW WCH024-042B100B, 060F1BAYHTRC112A 208/240/1/60 8.65/11.52 kW WCH024-042B100BBAYHTRC117A 208/240/1/60 12.98/17.28 kW WCH030-042B100B, 048F1, 060F1

Model No. Power Supply kW Ratings Nominal BTUH No. of Stages Used With

BAYHTRC306A 208/240/3/60 4.33/5.76 14,800/19,700 1 WCH036-042B300BBAYHTRC312A 208/240/3/60 8.65/11.52 29,500/39,300 1 WCH036-042B300BBAYHTRC317A 208/240/3/60 12.98/17.28 44,300/59,000 1 WCH036-042B300B

BAYHTRC406A 480/3/60 5.76 19,700 1 WCH036-042B400BBAYHTRC412A 480/3/60 11.52 39,300 1 WCH036-042B400BBAYHTRC417A 480/3/60 17.28 59,000 1 WCH036-042B400B

For information on Roof Curbs and Roof Curb Adaptors,please refer to the Accessories/Information Tab.

Page 190: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PH-23 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

PHASED OUT

PHASED OUT

PHASED OUT

PHASED OUT

Package HP ManufacturedHousing – 2½ through 3½ Tons

• Crankcase heater• Protected pressure taps for refrigerant

checks• Heavy gauge steel cabinet with weather

resistant, baked enamel finish• Fully insulated air handling compartment• Convenient access panels• 5-year limited compressor and coil warranty

(Residental)• 5-year limited parts warranty

(Residental)• 5-year compressor only limited warranty

(Commercial)• 1-year limited parts warranty (Commercial)

WCM• Climatuff® compressor• High efficiency performance• Two-speed evaporator blower motor• Round duct connections for manufactured

housing applications• Quiet operating top condenser air discharge• Copper tube/aluminum fin coils• Totally enclosed, permanently lubricated

condenser fan motor• Hermetically sealed compressor with

internal relief valve• Fully charged R-22 system• Sloped Drain Pan• Liquid line filter-drier• Heating expansion device/cooling FCCV

Table PH-23-A — Mobile Home Heat Pumps (208-230/1/60)Unit Cooling Dimensions Round Round ShippingModel Capacity (in.) Supply Return Weight Max SoundNo. SEER/EER (Btuh) H x W x L Opening Opening (Ibs.) MCA* Fuse* Rating Comp.

WCM030F100B 10.0/9.50 29,800 29 x 36 x 55 (B) 12 12 376 23.4 35 80 R1WCM036F100B 10.0/9.50 36,000 29 x 36 x 55 (B) 12 12 406 26.0 40 80 R2WCM042F100B 10.09.20 41,500 29 x 36 x 55 (B) 14 14 416 31.8 50 80 R2

Table PH-23-B — Supplementary Heaters – Separate Power Source/Power Entry RequiredModel No. Description Used With

BAYHTRN105A 3.74/4.98 kW Heater (208/240 volts) All WCM-F ModelsBAYHTRN108A 5.76/7.68 kW Heater (208/240 volts) All WCM-F ModelsBAYHTRN110A 7.47/9.96 kW Heater (208/240 volts) All WCM-F ModelsBAYHTRN112A 8.65/11.52 kW Heater (208/240 volts) All WCM-F ModelsBAYHTRN115A 11.21/14.94 kW Heater (208/240 volts) All WCM-F ModelsBAYHTRN117A 12.98/17.28 kW Heater (208/240 volts) All WCM-F Models

Table PH-23-C — AccessoriesModel No. Description Used With

BAYECMT002A Extreme Conditions Mounting Kit (Curb Mount) All WCM ModelsBAYECMT003A Extreme Conditions Mounting Kit (Slab or Rack Mount) All WCM ModelsBAYFLTR012A Filter Frame (20 x 25 x 1" filter not included) All WCM-F ModelsBAYGARD017A Condenser Coil Guard WCM030, 036FBAYGARD019A Condenser Coil Guard WCM042FBAYHSMT043A High Static Motor All WCM-F ModelsBAYKSKT010A Quick Start Kit All WCM-F Models

Table PH-23-D — Comfort ControlsModel No. Description Used With

BAY28X138A Auto Changeover All WCM ModelsBAYSTAT033A Outdoor Thermostat All WCM ModelsBAYSTAT239A Manual Heat Pump All WCM ModelsTAYSTAT500C XT 500C Manual Programmable 3 Htg/2 Clg All WCM ModelsTCONT402A 3Heat/2Clg (Heat Pump/A/C) All WCM ModelsTCONT602A 2Heat/2Clg (Heat Pump/A/C) All WCM ModelsTCONT802A 3Heat/2Clg (Heat Pump/A/C) All WCM ModelsTCONT803A 3Heat/2Clg (Heat Pump/A/C) w/Humidity Control All WCM Models

* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.Compressor Types are: R1 = Reciprocating One Cylinder, R2 = Reciprocating Two Cylinder, S = Scroll

For information on Roof Curbs and Roof Curb Adaptors,please refer to the Accessories/Information Tab.

Page 191: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PH-24Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Standard Features:• Trane built scroll compressors on all 4-10 ton units. 3 ton unit has a Reciprocating

Compressor• ReliaTel™ Controls (See page PC-35 for ReliaTel™ Control Information)• Colored and numbered wiring• Provisions for through the Base Condensate Drain Connections• Patented Hybrid Condenser Coil for easy cleaning• 1" throwaway filters provided on 3-5 ton units• 2" throwaway filters provided on 6-10 ton units• Liquid Line Refrigerant Drier• Operating Charge of R-22• IAQ Sloped Drain Pans• Single point power for electric Heat• Low Ambient cooling to 0°F• 5 - year Limited Compressor Warranty• 1 - year Limited Parts Warranty

Added Flexibility• Convertible airflow• Fork lift openings on three sides of unit• Direct or belt drive - standard or oversized motors (Direct for 3-5 ton only)• We don’t prepackage options• Choose options tailored to suit each job —pay only for what is needed• Units ship with options installed —and within our standard ship cycle time

Factory Installed Options

• Through-the-Base — Electrical• Convenience Outlet — Powered or unpowered• Unit Disconnect Switch• Smoke Detectors — Supply, return, or both• Condenser Coil Coating• Hinged Access Service Panels• Discharge Air Sensor• Fan Fail and Clogged Filter Switches• Condenser Coil Guard — Hail Protection Quality• TCI (Trane Communication Interface)• LonTalk (Communication Interface)• 2" Pleated Media filters• Phase Monitor

The same Trane Quality andReliability … with added Flexibility!

Precedent™ 3-10 tonPackaged Heat Pumps

FeaturingA New Look for a New Century

Beveled TopSmoother DesignSmall compact cabinetRecessed access handles

Page 192: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PH-25 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Precedent™ Packaged Heat PumpConvertible 3-10 Tons

Table PH-25-A — Base Unit — Standard Efficiency — ReliaTel™ Microprocessor ControlsCooling Cabinet Shipping

Unit Performance22222 Capacity Dimensions (in.) Downflow Downflow Weight Max1Tons Ordering No.33333 SEER/EER (Btuh) H x W x L Supply Return (Ibs.) MCA* Fuse*

WSC – 208-230/1/60 – Single Phase – No Heat3 WSC036E1R0A0000 13.0 37,650 32 x 44 x 70 18 x 15.5 24 x 14 589 31.2 454 WSC048E1R0A0000 13.0 49,040 32 x 44 x 70 18 x 15.5 24 x 14 600 38.9 605 WSC060E1R0A0000 13.0 58,360 41 x 53 x 89 33 x 17.5 32.13 x 17.5 825 44.6 70WSC – 208-230/3/60 – Three Phase – No Heat3 WSC036A3R0A0000 10.2 38,100 32 x 44 x 70 18 x 15.5 24 x 14 534 19.1 304 WSC048A3R0A0000 10.7 50,800 32 x 44 x 70 18 x 15.5 24 x 14 566 24.4 355 WSC060A3R0A0000 10.1 62,100 32 x 44 x 70 18 x 15.5 24 x 14 584 32.6 503 WSC036E3R0A0000 13.0 38,030 32 x 44 x 70 18 x 15.5 24 x 14 589 23.8 354 WSC048E3R0A0000 13.0 50,130 32 x 44 x 70 18 x 15.5 24 x 14 600 27.5 405 WSC060E3R0A0000 13.0 63,440 41 x 53 x 89 33 x 17.5 32.13 x 17.5 825 30.2 456 WSC072A3R0A0000 10.6 72,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 32.2 5071/2 WSC090A3R0A0000 10.1 92,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 937 41.4 6010 WSC120A3R0A0000 10.1 119,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1084 50.4 60WSC – 460/3/60 – Three Phase – No Heat3 WSC036A4R0A0000 10.2 38,100 32 x 44 x 70 18 x 15.5 24 x 14 534 9.9 154 WSC048A4R0A0000 10.7 50,800 32 x 44 x 70 18 x 15.5 24 x 14 566 12.1 155 WSC060A4R0A0000 10.1 62,100 32 x 44 x 70 18 x 15.5 24 x 14 584 16.6 253 WSC036E4R0A0000 13.0 38,030 32 x 44 x 70 18 x 15.5 24 x 14 589 11.4 154 WSC048E4R0A0000 13.0 50,130 32 x 44 x 70 18 x 15.5 24 x 14 600 12.3 155 WSC060E4R0A0000 13.0 63,440 41 x 53 x 89 33 x 17.5 32.13 x 17.5 825 14.7 206 WSC072A4R0A0000 10.6 72,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 16.6 2571/2 WSC090A4R0A0000 10.1 92,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 937 21.9 3510 WSC120A4R0A0000 10.1 119,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1084 26.4 35WSC – 575/3/60 – Three Phase – No Heat3 WSC036AWR0A0000 10.2 38,100 32 x 44 x 70 18 x 15.5 24 x 14 534 8.3 154 WSC048AWR0A0000 10.7 50,800 32 x 44 x 70 18 x 15.5 24 x 14 566 10.1 155 WSC060AWR0A0000 10.1 62,100 32 x 44 x 70 18 x 15.5 24 x 14 584 13.1 203 WSC036EWR0A0000 13.0 38,030 32 x 44 x 70 18 x 15.5 24 x 14 589 8.8 154 WSC048EWR0A0000 13.0 50,130 32 x 44 x 70 18 x 15.5 24 x 14 600 9.5 155 WSC060EWR0A0000 13.0 63,440 41 x 53 x 89 33 x 17.5 32.13 x 17.5 825 11.0 156 WSC072AWR0A0000 10.6 72,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 12.5 1571/2 WSC090AWR0A0000 10.1 92,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 937 16.8 2510 WSC120AWR0A0000 10.1 119,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1084 21.0 25

* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.1 HCAR breaker per NEC.2 SEER applies, 3-5 tons; EER applies 6-10 tons.3 Digit 7 - A=R-22, E=410A.

Page 193: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PH-26Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Precedent™ Packaged Heat PumpConvertible 3-10 Tons(Model Digit Numbers)

Digit Description Order Number1-8 Main Assembly (see previous page)9 Unit Controls

Unit Controls -ReliaTel™ Micro-processor .................. R10 (See Heater Table below)11 Minor Design Sequence

First Sequence ........................................................ A12-13 Service Sequence

First Sequence (Factory Assiged) ............................ ✱,✱14 Fresh Air Selection

No Fresh Air ............................................................. 00-50% Manual Outside Air Damper9 ......................... A0-50% Motorized Outside Air Damper ........................ B0-100% Economizer, Dry Bulb without

Barometric Relief 1 ............................................... C0-100% Economizer, Dry Bulb with

Barometric Relief1 ............................................... D0-100% Economizer, Reference Enthalpy

without Barometric Relief1 ..................................... E0-100%Economizer, Reference Enthalpy

with Barometric Relief1 ......................................... F0-100%Economizer, Comparative Enthalpy

without Barometric Relief 1 ................................... G0-100%Economizer, Comparative Enthalpy

with Barometric Relief 1 ......................................... H15 Supply Fan/Drive Type/Motor

Standard Drive ......................................................... 0Oversized Motor ....................................................... 1Optional Belt Drive Motor (3 phase only) .................... 2

16 Hinged Service Access & FiltersStandard Panels & Filters ......................................... 0Hinged Access Panels & Standard Filters .................. AStandard Panels & 2" Pleated Filters ......................... BHinged Access Panels & 2" Pleated Filters ................ C

17 Condenser Coil ProtectionStandard Coil ........................................................... 0Standard Coil with Hail Guard ................................... 1Epoxy Coated Condenser Coil .................................. 2Epoxy Coated Condenser Coil with Hail Guard .......... 3

18 Through the Base ProvisionsNo Through the Base Provisions ............................... 0Through the Base Electric8 ...................................... A

19 Disconnect/Circuit Breaker/Phase Monitor (3 phase only)No Disconnect /Circuit Breaker/No Phase Monitor ...... 0Non-Fused Disconnect8 ........................................... 1Circuit Breaker8 ....................................................... 2Phase Monitor0 ....................................................... 3Phase Monitor0 & Non-Fused Disconnect Switch ...... 4Phase Monitor0 & Circuit Breaker ............................. 5

20 Convenience OutletNo Convenience Outlet ............................................. 0Unpowered Convenience Outlet ............................... APowered Convenience Outlet (3 phase only)2 ............ B

21 Communications OptionsNo Communications Interface ................................... 0Trane Communications Interface ............................... 1LonTalk® Communications Interface .......................... 2

22 Refrigeration System OptionStandard Refrigeration System ................................. 0

23 Refrigeration ControlsNo Refrigeration Control ........................................... 0High Pressure Control5 ............................................ 1Frostat4 ................................................................... 2Crankcase Heater .................................................... 3High Pressure Control5 and Frostat4 ........................ 4High Pressure Control5 and Crankcase Heater .......... 5Frostat4 and Crankcase Heater5 ............................. 6High Pressure Control5, Frostat4 and

Crankcase Heater5 .............................................. 724 Smoke Detector67

No Smoke Detector .................................................. 0Return Air Smoke Detector ....................................... ASupply Air Smoke Detector ....................................... BSupply and Return Air Smoke Detectors .................... C

25 Monitoring ControlsNo Monitoring Control ............................................... 0Clogged Filter Switch ................................................ 1Fan Failure Switch .................................................... 2Discharge Air Sensing Tube ...................................... 3Clogged Filter Switch and Fan Fail Switch .................. 4Clogged Filter Switch and Discharge

Air Sensing Tube .................................................... 5Fan Fail Switch and Discharge Air Sensing Tube ......... 6Clogged Filter and Fan Fail Switches

and Discharge Air Sensing Tube ............................. 71 Economizer with Barometric Relief is for downfllow configured units only. Order Economizer without

Barometric Relief for horizontal configuration. Barometric relief for horizontal configured units mustbe ordered as field installed accessory BAYBARM010A.

2 Requires use of Disconnect or Circuit Breaker.3 Standard refrigeration metering device - short orifice.4 Frostat cannot be field installed in electro-mechanical units.5 High Pressure control is standard on 3 phase units with scroll compressor and WSC036A.6 Not available with BAYFRST001A High Temperature Stat accessory.7 The return air smoke detector may not fit up or work properly on the Convertible units when used in

Digit Description Order Number

conjunction with 3rd party accessories such as bolt on heat wheels, economizers and powerexhaust. Do not order the return air smoke detectors when using this type of accessory.

8 Through the base electric required when ordering disconnect/circuit breaker options.9 The manual outside air damper will ship factory supplied within the unit, but must be field

installed.0 Phase Monitor is standard on T/Y/WSC060A3,4,W models. All other models Phase Monitor will

be an option.

Heaters (Digit 10)kW Nominal No.

Rating Digit BTUH Stages Used With208/240/1/60

3.8/5.0 (A) 12,800/17,100 1 WSC036-060A17.5/10.0 (D) 25,600/34,100 2 WSC036-060A1

10.4/13.8 (F) 35,300/47,100 2 WSC036-060A113.2/17.6 (G) 45,100/60,100 2 WSC048-060A1

208/240/3/604.5/6.0 (B) 13,400/20,500 1 WSC036-060A3

9.0/12.0 (E) 30,800/59,400 2 WSC036-060A313.1/17.4 (G) 44,600/59,400 2 WSC036-060A317.3/23.0 (J) 58,900/78,500 2 WSC060A36.75/9.0 (C) 23,000/30,700 1 W*C072-090A3

13.5/18.0 (G) 46,100/61,400 1 W*C072-120A320.3/27.0 (K) 69,000/92,100 2 W*C072-120A327.0/36.0 (N) 92,200/122,900 2 W*C072-120A340.5/54.0 (P) 138,200/184,300 2 W*C120A3

kW Nominal No.Rating Digit BTUH Stages Used With

460/3/606.0 (B) 20,500 1 WSC036-060A412.0 (E) 41,000 2 WSC036-060A417.4 (G) 59,400 2 WSC036-060A423.0 (J) 78,500 2 WSC060A49.0 (C) 30,700 1 W*C072-090A418.0 (G) 61,400 1 W*C072-120A427.0 (K) 92,100 2 W*C072-120A436.0 (N) 122,900 2 W*C072-120A454.0 (P) 184,300 2 W*C120A4

575/3/606.0 (B) 20,500 1 WSC036-060AW12.0 (E) 41,000 2 WSC036-060AW17.4 (G) 59,400 2 WSC036-060AW23.0 (J) 78,500 2 WSC060AW9.0 (C) 30,700 1 W*C072-090AW18.0 (G) 61,400 1 W*C072-120AW27.0 (K) 92,100 2 W*C072-120AW36.0 (N) 122,900 2 W*C072-120AW54.0 (P) 184,300 2 W*C120AW

Page 194: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PH-27 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Table PH-27-A — Accessory Electric Heaters – Unit with heater is single circuit / single point power entryModel Power kW Nominal No.Number Supply Rating BTUH Stages Used With11111

BAYHTRR105A 208/240/1/60 3.8/5.0 12,800/17,100 1 WSC036-060(A or E)1BAYHTRR110A 208/240/1/60 7.5/10.0 25,600/34,100 2 WS036-060(A or E)1BAYHTRR114A 208/240/1/60 10.4/13.8 35,300/47,100 2 WSC036-060(A or E)1BAYHTRR118A 208/240/1/60 13.2/17.6 45,100/60,100 2 WSC048-060(A or E)1BAYHTRR306A 208/240/3/60 4.5/6.0 13,400/20,500 1 WSC036-060(A or E)3BAYHTRR312A 208/240/3/60 9.0/12.0 30,800/41,000 2 WSC036-060(A or E)3BAYHTRR318A 208/240/3/60 13.1/17.4 44,600/59,400 2 WSC036-060(A or E)3BAYHTRR323A 208/240/3/60 17.3/23.0 58,900/78,500 2 WSC060(A or E)3BAYHTRS309A 208/240/3/60 6.75/9.0 23,000/30,700 1 WSC072-090A3BAYHTRS318A 208/240/3/60 13.5/18.0 46,100/61,400 1 WSC072-090A3BAYHTRS327A 208/240/3/60 20.3/27.0 69,000/92,100 2 WSC072-090A3BAYHTRS336A 208/240/3/60 27.0/36.0 92,200/122,900 2 WSC072-090A3BAYHTRT318A 208/240/3/60 13.5/18.0 46,100/61,400 1 WSC120A3BAYHTRT327A 208/240/3/60 20.3/27.0 69,000/92,100 2 WSC120A3BAYHTRT336A 208/240/3/60 27.0/36.0 92,200/122,900 2 WSC120A3BAYHTRT354A 208/240/3/60 40.5/54.0 138,200/184,300 2 WSC120A3

BAYHTRS409A 460/3/60 9.0 30,700 1 WSC072-090A4BAYHTRS418A 460/3/60 18.0 61,400 1 WSC072-090A4BAYHTRS427A 460/3/60 27.0 92,100 2 WSC072-090A4BAYHTRS436A 460/3/60 36.0 122,900 2 WSC072-090A4BAYHTRT418A 460/3/60 18.0 61,400 1 WSC120A4BAYHTRT427A 460/3/60 27.0 92,100 2 WSC120A4BAYHTRT436A 460/3/60 36.0 122,900 2 WSC120A4BAYHTRT454A 460/3/60 54.0 184,300 2 WSC120A4BAYHTRR406A 460/3/60 6.0 20,500 1 WSC036-060(A or E)4BAYHTRR412A 460/3/60 12.0 41,000 2 WSC036-060(A or E)4BAYHTRR418A 460/3/60 17.4 59,400 2 WSC036-060(A or E)4BAYHTRR423A 460/3/60 23.0 78,500 2 WSC060(A or E)4

BAYHTRSW09A 575/3/60 9.0 30,700 1 WSC072-090AWBAYHTRSW18A 575/3/60 18.0 61,400 1 WSC072-090AWBAYHTRTW18A 575/3/60 18.0 61,400 1 WSC120AWBAYHTRSW27A 575/3/60 27.0 92,100 2 WSC072-090AWBAYHTRTW27A 575/3/60 27.0 92,100 2 WSC120AWBAYHTRSW36A 575/3/60 36.0 122,900 2 WSC072-090AWBAYHTRTW36A 575/3/60 36.0 122,900 2 WSC120AWBAYHTRTW54A 575/3/60 54.0 184,300 2 WSC120AWBAYHTRRW06A 575/3/60 6.0 20,500 1 WSC036-060(A or E)WBAYHTRRW12A 575/3/60 12.0 41,000 2 WSC036-060(A or E)WBAYHTRRW18A 575/3/60 17.4 59,400 2 WSC036-060(A or E)WBAYHTRRW23A 575/3/60 23.0 78,500 2 WSC060(A or E)W

1 A = R-22, E = 410A

Table PH-27-B — Zone Sensors for ReliaTel™ Controlled UnitsModelNumber Description Used With33333

BAYMTPL003B Retrofit Wall Cover Plate Kit 7.25" x 6.0" BAYSENS019CBAYMTPL004B Retrofit Wall Cover Plate Kit 4.75" x 4.75" BAYSENS007B,009B,011B,013,014C,017BBAYSENS007B Single Setpoint Manual Changeover WSC036-060(A or E)-120ABAYSENS009B Dual Setpoint Manual or Auto Changeover WSC036-060(A or E)-120ABAYSENS011B Dual Setpoint Man. or Auto Change-over with System

Function Lights WSC036-060(A or E)-120ABAYSENS013C1 Room Sensor w/ Override and Cancel Buttons WSC036-060(A or E)-120ABAYSENS014C1 Room Sensor w/ Temp. Adjustment with Override and

Cancel Buttons WSC036-060(A or E)-120ABAYSENS017B Remote Room Sensor 010B, & 019C BAYSENS007B,009B,011B,019CBAYSENS019C Programmable Night Setback w/System Function Lights WSC036-060(A or E)-120ABAYSENS031A2 Digital Display Zone Sensor WSC036-060(A or E)-120ABAYSENS032A2 Dual Thermistor Remote Zone Sensor WSC036-060(A or E)-120A

1 Used with Integrated ComfortTM Systems, any unit type. These sensors do not work with TCM. Consult BASD Marketing for them.2 Functional only with ReliaTel™ controls.3 A=R-22, E=410A

Precedent™ Packaged Heat PumpConvertible 3-10 Tons

Page 195: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PH-28Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Precedent™ Packaged Heat PumpConvertible 3-10 Tons

Table PH-28-A — AccessoriesModel Number Description Used Withrrrrr

BAYABRD001C ........................... ReliaTel™ Options Module ..................................................... See Note6BAYBARM010A3 ....................... Barometric Relief .................................................................... WSC036-060(A or E)BAYBARM011A3 ....................... Barometric Relief .................................................................... WSC072-120ABAYCCHT010B ........................... Crankcase Heater .................................................................. WSC036-060(A or E), WSC072-120A1, A3BAYCCHT011B ........................... Crankcase Heater .................................................................. WSC036-060(A or E), WSC072-120A1, A4, AWBAYCCHT012A ........................... Crankcase Heater .................................................................. WSC090A3BAYCCHT013A ........................... Crankcase Heater .................................................................. WSC090A4BAYCCHT014A ........................... Crankcase Heater .................................................................. WSC090AWBAYCO2K001Bw ........................ CO2 Sensor Kit, Wall Mounted ............................................... WSC036-060(A or E), WSC072-120A w/EconomizerBAYCO2K003Bw ........................ CO2 Sensor Kit, Duct Mounted .............................................. WSC036-060(A or E), WSC072-120A w/EconomizerBAYCURB042A4 ....................... Roof Curb ............................................................................... WSC036-060(A or E)BAYCURB043A4 ....................... Roof Curb ............................................................................... WSC072-120ABAYDFPS003A6 ........................ Clogged Filter Switch ............................................................. WSC036-060(A or E)-120ABAYDFPS004A6 ........................ Fan Failure Switch .................................................................. WSC036-060(A or E)-120ABAYDMPR051A .......................... 0-50% Motorized Outside Air Damper .................................... WSC036-060(A or E)BAYDMPR053Be ....................... 0-50% Manual Outside Air Damper ........................................ WSC036-060(A or E)BAYDMPR054A .......................... 0-50% Motorized Outside Air Damper .................................... WSC072-120ABAYDMPR056Be ....................... 0-50% Manual Outside Air Damper ........................................ WSC072-120ABAYECON085A ........................... 0-100% Economizer without Barometric Relief ....................... WSC036-060(A or E)BAYECON087A ........................... 0-100% Economizer without Barometric Relief ....................... WSC072-120ABAYENTH005A1 ........................ Reference Enthalpy Kit ........................................................... BAYECON085A,087ABAYENTH006B1 ........................ Comparative Enthalpy Kit ....................................................... BAYECON085A,087ABAYFRST001A7 ........................ High Temperature Stat ............................................................ WSC036-060(A or E), WSC072-120ABAYGARD036B ........................... Condenser Coil Hail Guard ..................................................... WSC036-060(A or E)BAYGARD040B ........................... Condenser Coil Hail Guard ..................................................... WSC072-090ABAYGARD041B ........................... Condenser Coil Hail Guard ..................................................... WSC120ABAYHSDR012A ........................... High Static Drive Kit ............................................................... WSC072ABAYHSMT073A ........................... .45 HP Direct Drive Oversized Motor Kit ................................. WSC036(A or E)1,(A or E)3BAYHSMT074A ........................... .45 HP Direct Drive Oversized Motor Kit ................................. WSC036(A or E)4BAYHSMT075A ........................... .45 HP Direct Drive Oversized Motor Kit ................................. WSC036(A or E)WBAYHSMT076A ........................... .75 HP Direct Drive Oversized Motor Kit ................................. WSC048(A or E)1,(A or E)3BAYHSMT077A ........................... .75 HP Direct Drive Oversized Motor Kit ................................. WSC048(A or E)4BAYHSMT078A ........................... .75 HP Direct Drive Oversized Motor Kit ................................. WSC048(A or E)WBAYHSMT079A ........................... 1.2 HP Direct Drive Oversized Motor Kit ................................. WSC060(A or E)1,(A or E)3BAYHSMT080A ........................... 1.2 HP Direct Drive Oversized Motor Kit ................................. WSC060(A or E)4BAYHSMT081A ........................... 1.2 HP Direct Drive Oversized Motor Kit ................................. WSC060(A or E)WBAYHSMT082A ........................... 2 HP Belt Drive Oversized Motor ............................................ WSC072A3, A4BAYHSMT083A ........................... 2 HP Belt Drive Oversized Motor ............................................ WSC072AWBAYHSMT086A ........................... 3 HP Belt Drive Oversized Motor ............................................ WSC090A3, A4BAYHSMT087A ........................... 3 HP Belt Drive Oversized Motor ............................................ WSC090AWBAYHSMT090A ........................... 5 HP Belt Drive Oversized Motor ............................................ WSC120A3, A4BAYHSMT091A ........................... 5 HP Belt Drive Oversized Motor ............................................ WSC120AWBAYICSI003A8 ........................... Trane Communications Interface ............................................ WSC036-060(A or E), WSC072-120ABAYKSKT255A ............................ Quick Start Kit ........................................................................ WSC048,060(A or E)A1BAYKSKT256A ............................ Quick Start Kit ........................................................................ WSC036(A or E)1BAYLOAM020B6 ....................... Evaporator Defrost Control (Frostat) ....................................... WSC036-060(A or E), WSC072-120ABAYLTCI002B0 .......................... LonTalk® Communications Interface ...................................... WSC036-060(A or E), WSC072-120ABAYPWRX026A9 ....................... Power Exhaust ....................................................................... WSC072-120A3BAYPWRX027A9 ....................... Power Exhaust ....................................................................... WSC072-120A4BAYPWRX028A9 ....................... Power Exhaust ....................................................................... WSC072-120AWBAYQACB009A45 .................... Quick Adapt Roof Curb ........................................................... WSC036-060(A or E)BAYQACB010A45 .................... Quick Adapt Roof Curb ........................................................... WSC036-060(A or E)BAYQACB011A4q .................... Quick Adapt Roof Curb ........................................................... WSC036-060(A or E), WSC072-120ABAYQACB012A4q .................... Quick Adapt Roof Curb ........................................................... WSC036-060(A or E), WSC072-120ABAYSENS016A ........................... Temperature Sensor ............................................................... WSC036-060(A or E)BAYSERV001A ........................... Selective Resistance Service Tester ....................................... WSC036-060(A or E), WSC072-120ABAYSTAT023 ............................... Remote Potentiometer ............................................................ BAYECON085A,087ABAYTUBE005A26 ..................... Discharge Air Sensing Kit ....................................................... WSC036-060(A or E)BAYTUBE007 .............................. Discharge Air Sensing Kit ....................................................... WSC072-120ABAYVNOR001Bw6 .................... Ventilation Override Kit w/ReliaTel™ options module .............. WSC036-060(A or E), WSC072-120A

1 Kits contain all necessary parts to achieve desired level of enthalpy control.2 Used for true discharge air sensing in both heating and cooling. Required for supply air tempering.3 Barometric Relief accessory installs in ductwork for horizontal configuration. For downflow configuration, installs in the unit's horizontal return duct. See Installer's Guide for complete

instructions.4 Lynn Haven manufacturing has a no return policy for this roof curb.5 BAYQACB009A adapts Voyager BAYCURB021A roof curb to accept Precedent 3-5 ton unit. BAYQACB010A adapts Voyager (BAYCURB022A roof curb to accept Precedent 3-5 ton unit.6 BAYABRD001C is required when ordering field installed accessories Clogged Filter Switch (BAYDFPS003A), Fan Fail Switch (BAYDFPS004A), Discharge Air Sensing Kit BAYTUBE004A

or BAYTUBE005A) or Evaporator Defrost Control (Frostat) (BAYLOAM020B) Ventilation Override Kit (BAYVNOR001B) unless the following options are factory installed: Frostat, SmokeDetector, Clogged Filter Switch, Fan Failure Switch, Discharge Air Sensing Kit. These factory installed options Include the ReliaTel™ Options Module.

7 Cannot be used in conjunction with factory installed smoke detector.8 Interface allows unit to communicate with Tracer 100, Tracker, VariTrac II, and is the preferred method of communication to Tracer Summit.9 Power Exhaust cannot be used with Barometric Relief. Order Economizer without Barometric Relief.0 Interface allows unit to communicate as a Trane LonTalk device or directly with generic LonTalk Network BAS Controls.q BAYQACB012A adapts Voyager BAYCURB025 roof curb to accept Convertible 6-10 ton unit.BAYQACB011A adapts Voyager BAYCURB022B roof curb to accept Precedent 6-10 ton unit.w Field installed accessory. Requires an economizer.e The manual outside air damper will ship factory supplied within the unit, but must be field installed.r A=R-22, E=410A.

Page 196: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PH-29 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Light Commercial Packaged HeatPump New Model Quick Reference

Table PH-29-A — Quick ReferencePrecedent™ Precedent™

Voyager Horizontal Voyager Downflow Controls Ordering Number Service Model Number

WCH036B100A WCD036C100B Microprocessor WSC036*1R0A0000 WSC036*1R0A**000000000000WCH036B300A WCD036C300B Microprocessor WSC036*3R0A0000 WSC036*3R0A**000000000000WCH036B400A WCD036C400B Microprocessor WSC036*4R0A0000 WSC036*4R0A**000000000000WCH048C100B WCD048C100B Microprocessor WSC048*1R0A0000 WSC048*1R0A**000000000000WCH048C300B WCD048C300B Microprocessor WSC048*3R0A0000 WSC048*3R0A**000000000000WCH048C400B WCD048C400B Microprocessor WSC048*4R0A0000 WSC048*4R0A**000000000000WCH048CW00B WCD048CW00B Microprocessor WSC048*WR0A0000 WSC048*WR0A**000000000000WCH060C100B WCD060C100B Microprocessor WSC060*1R0A0000 WSC060*1R0A**000000000000WCH060C300B WCD060C300B Microprocessor WSC060*3R0A0000 WSC060*3R0A**000000000000WCH060C400B WCD060C400B Microprocessor WSC060*4R0A0000 WSC060*4R0A**000000000000WCH060CW00B WCD060CW00B Microprocessor WSC060*WR0A0000 WSC060*WR0A**000000000000WCH075C300B WCD075C300B Microprocessor WSC072A3R0A0000 WSC072A3R0A**000000000000WCH075C400B WCD075C400B Microprocessor WSC072A4R0A0000 WSC072A4R0A**000000000000WCH075CW00B WCD075CW00B Microprocessor WSC072AWR0A0000 WSC072AWR0A**000000000000WCH090C300B WCD090C300B Microprocessor WSC090A3R0A0000 WSC090A3R0A**000000000000WCH090C400B WCD090C400B Microprocessor WSC090A4R0A0000 WSC090A4R0A**000000000000WCH090CW00B WCD090CW00B Microprocessor WSC090AWR0A0000 WSC090AWR0A**000000000000WCH120B300E WCD120B300E Microprocessor WSC120A3R0A0000 WSC120A3R0A**000000000000WCH120B400E WCD120B400E Microprocessor WSC120A4R0A0000 WSC120A4R0A**000000000000

WCH120BW00E WCD120BW00E Microprocessor WSC120AWR0A0000 WSC120AWR0A**000000000000* Digit 7- A=R-22, E=410A.

For additional Controls Information:See ReliaTel™ and Micro Control features on PC-35 and PC-36.

Page 197: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PH-30Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Voyager™ PackagedHeat Pump with ReliaTel™Controls 12½ through 20 Tons

• Single point power for electric heat• Complete line of optional electric heaters• Internally enhanced coil tubing• Low ambient to 0°F standard• Colored and numbered wiring• Common cabinet and accessories as

TCD/TCH and YCD/YCH models• Quick-adjust idler arm pulley.• 5-year limited compressor warranty

(12½ – 15 tons)• 1-year limited parts warranty• 1-year limited compressor warranty (20

tons)

• EER up to 10.0• ReliaTel™ processor control features are

listed on page PC-35• Built-in anti-short cycle, time-delay relay

and minimum on time controls• 2" filters for 12½ - 20 ton units• Liquid line drier• Built-in fork lift holes• Operating charge of R-22• “Quick-Sess” service panels slide in

and out• Scroll compressors• Dedicated horizontal and downflow designs• Single-side access

12½ – 20 TonWCD/WCH—Downflow/Horizontal

Supply Supply Return Return Curb Size Roof OpeningTons Downflow W x L1212121212 Horizontal H x W1212121212 Downflow W x L1212121212 Horizontal H x W1212121212 H x W x L2424242424 W x L1212121212

121/2 – 15 289/16 x 551/2 421/2 x 261/2 207/8 x 63 421/2 x 249/16 141/16 x 6615/16 x 1021/4 621/2 x 731/220 289/16 x 691/2 467/16 x 261/2 221/4 x 77 467/16 x 279/16 141/16 x 8015/16 x 1171/8 761/2 x 81

Table PH-30-A — WCD Downflow or WCH Horizontal — Micro Control UnitUnit Power Supply Performance Cooling Dimensions (in.) Shipping Max Fuse Size or55555 Downflow

Tons Model No. Volts/Phase/Hz EER (1Ø) Capacity (Btuh) H x W x L Weight (Ibs.) MCA33333 Max Circuit Breaker Roofcurb

121/2 WCD150B300G 208-230/3/60 9.50 152,000 501/8 x 715/16 x 1075/16 1719 66 80 BAYCURB026B15 WCD180B300H 208-230/3/60 9.60 180,000 501/8 x 715/16 x 1075/16 1857 76 90 BAYCURB026B20 WCD240B300G 208-230/3/60 10.0 244,00 54 x 855/16 x 1225/16 2467 96 125 BAYCURB027B121/2 WCD150B400G 460/3/60 9.50 152,000 501/8 x 715/16 x 1075/16 1719 31 40 BAYCURB026B15 WCD180B400H 460/3/60 9.60 180,000 501/8 x 715/16 x 1075/16 1857 39 45 BAYCURB026B20 WCD240B400G 460/3/60 10.0 244,000 54 x 855/16 x 1225/16 2467 49 60 BAYCURB027B121/2 WCD150BW00G 575/3/60 9.50 152,000 501/8 x 715/16 x 1075/16 1719 25 30 BAYCURB026B15 WCD180BW00H 575/3/60 9.60 180,000 501/8 x 715/16 x 1075/16 1857 31 35 BAYCURB026B20 WCD240BW00G 575/3/60 10.0 244,000 54 x 855/16 x 1225/16 2467 38 45 BAYCURB027B121/2 WCH150B300G 208-230/3/60 9.50 152,000 501/8 x 715/16 x 1075/16 1719 66 80 BAYCURB026B15 WCH180B300H 208-230/3/60 9.60 180,000 501/8 x 715/16 x 1075/16 1857 76 90 BAYCURB026B20 WCH240B300G 208-230/3/60 10.0 244,000 54 x 855/16 x 1225/16 2467 96 125 BAYCURB027B121/2 WCH150B400G 460/3/60 9.50 152,000 501/8 x 715/16 x 1075/16 1719 31 40 BAYCURB026B15 WCH180B400H 460/3/60 9.60 180,000 501/8 x 715/16 x 1075/16 1857 39 45 BAYCURB026B20 WCH240B400G 460/3/60 10.0 244,000 54 x 855/16 x 1225/16 2467 49 60 BAYCURB027B121/2 WCH150BW00G 575/3/60 9.50 152,000 501/8 x 715/16 x 1075/16 1719 25 30 BAYCURB026B15 WCH180BW00H 575/3/60 9.60 180,000 501/8 x 715/16 x 1075/16 1857 31 35 BAYCURB026B20 WCH240BW00G 575/3/60 10.0 244,000 54 x 855/16 x 1225/16 2467 38 45 BAYCURB027B

Page 198: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PH-31 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Table PC-31-A — Factory Installed Accessories12 For Complete list of all Factory Installed Options, please refer to the FIOPSsection of this book.Digit Description Order Number Used With

1-8 Main Assembly (see previous page)9-10 Factory Installed Options

No Options 00 WC*150-240Downflow Economizer3 0A WCD150-240Oversized Motor 0B WC*150-240Downflow Economizer and Oversized Motor3 0C WCD150-240Trane Communications Interface (TCI)4 0F WC*150-240Downflow Economizer TCI34 0G WCD150-240

11-12 Minor Design and Service Sequence **1 Price includes accessory and factory installation.2 Four (4) week shipping approximately.3 Some field set up required.4 TCI is for use with non-VariTrac systems and VariTrac systems.

Table PH-31-B — Zone SensorsModel Number Description Used With

BAYSENS007B ............ Single Setpoint Manual Changeover with Emergency Heat ........................... WC*150-240BAYSENS009B ............ Dual Setpoint Manual or Automatic Changeover with Emergency Heat .......... WC*150-240BAYSENS011B ............ Dual Setpoint Manual or Automatic Changeover with System ........................ WC*150-240

Function Light and Emergency HeatBAYSENS013C1 ........ Room Sensor with Override Button ............................................................. WC*150-240BAYSENS014C1 ........ Room Sensor with Temperature Adjustment ................................................ WC*150-240BAYSENS019C ............ Programmable Night Setback ..................................................................... WC*150-240BAYSENS017B ............ Remote Room Sensor ............................................................................... BAYSENS007B, 009B, 011B, 019CBAYSENS031Aq ......... Digital Display Zone Sensor ....................................................................... WC*150-240BAYSENS032Aq ......... Dual Thermistor Remote Zone Sensor ....................................................... WC*150-240BAYMTPL003B ............ Retrofit Wall Cover Plate Kit (71/4" x 6") ......................................................... BAYSENS019CBAYMTPL004A .............. Retrofit Wall Cover Plate Kit (41/4" x 41/4") .......................................................... BAYSENS007B, 009B, 011B, 017B,

013C, 014C

Voyager™ PackagedHeat Pump with ReliaTel™Controls 12½ through 20 Tons

Page 199: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PH-32Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Table PH-32-A — Field Installed Accessories For complete list of of All Factory Installed Options refer to FIOPS section of thisbook.Model Number Description Used With

BAYABRD002Bq ........... ReliaTel™ Options Module .......................................... WCH/D150-240BAYCO2K002Bw ........... CO2 Sensor Wall Mounted ........................................... WC*150-240 w/EconomizerBAYCO2K004Bw ........... CO2 Sensor Duct Mounted .......................................... WC*150-240 w/EconomizerBAYCURB026B89 ........ Downflow Only Roof Curb ............................................ WCD150B, 180BBAYCURB027B89 ........ Downflow Only Roof Curb ............................................ WCD240BBAYECON089Aq ........... Downflow Economizer with Barometric Relief ................ WCD150B, 180BBAYECON090Aq ........... Downflow Economizer with Barometric Relief ................ WCD240BBAYECON091A .............. Horizontal Economizer ................................................. WCH150B, 180BBAYECON092A .............. Horizontal Economizer ................................................. WCH240BBAYFRST003A .............. High Temperature Stat ................................................ WC*150-240 w/ICSBAYENTH007A .............. Reference Enthalpy Kit ................................................ All BAYECON089-92ABAYENTH008A .............. Comparative Enthalpy Kit ............................................ All BAYECON089-92ABAYDMPR029C ............. 0-25% Manual Outside Air Damper ............................... WCD/WCH (12½-20 Tons)BAYDMPR0057A ............ 0-50% Motorized Outside Air Damper ........................... WCD/WCH150B, 180BBAYDMPR058A ............. 0-50% Motorized Outside Air Damper ........................... WCD/WCH240BBAYDFPS005A0q ......... Clogged Filter Switch ................................................... WCD/WCH (12½-20 Tons)BAYDFPS006A0q ......... Fan Failure Switch ....................................................... Economizers/0-50% Motorized Air DampersBAYGARD043Bq ........... Tool-less Hail Guard .................................................... WC*150BBAYGARD044Bq ........... Tool-less Hail Guard .................................................... WC*180BBAYGARD045Aq ........... Tool-less Hail Guard .................................................... WC*240BBAYPWRX029A ............. Power Exhaust for 230 volt units ................................... BAYECON089,090 (WCD150B, 180B, 240B3)BAYPWRX030A ............. Power Exhaust for 460 volt units ................................... BAYECON089,090 (WCD150B, 180B, 240B4)BAYPWRX031A ............. Power Exhaust for ....................................................... WCD150,180,240BWBAYHSDR002B6 .......... High Static Drive .......................................................... WCD/WCH150BBAYHSMT039B6q ........ 5HP Oversized Motor Kit .............................................. WCD/WCH150B, 180BBAYHSMT040B6q ........ 5HP Oversized Motor Kit .............................................. WC*150, 180BWBAYHSMT042A .............. 7-1/2HP Oversized Motor Kit ........................................ WC*240BWBAYHSMT098A6q ........ 7-1/2HP Oversized Motor Kit ........................................ WC*240B3BAYHSMT099A6q ......... 7-1/2HP Oversized Motor Kit ........................................ WC*240B4BAYICSI004Ber ............ Trane Communications Interface, Comm 3/4 (TCI) ......... WC*150-300BAYLOAM023A0q ......... Evaporator Deforst Control (Frostat) .............................. WC*150-240BAYLTCI003Br .............. LonTalk® Communications Inteface (LCI) ....................... WC*150-300BAYSERV001A .............. Selective Resistance Service Tester .............................. WCD/WCH (12½-20 Tons)BAYSTAT023 ................. Remote Potentiometer ................................................ All BAYECON089-92ABAYSENS016A .............. Temperature Sensor .................................................... WCD/WCH (12½-20 Tons)BAYTUBE008A70q ....... Discharge Air Sensing Kit ............................................. WCD150-240BAYTUBE009A70q ....... Discharge Air Sensing Kit ............................................. WCH150-240BAYVNOR002B0 ......... Ventilation Override Kit ............................................. WCH150-240 w/ReliaTel™ Options Module1 Dimensions are in inches.2 Interior Dimension.3 MCA = Minimum Circuit Ampacity.4 Measurement Includes Curb Flange.5 HACR Type Circuit per NEC.6 High static drive and oversized motors are mutually exclusive, Do not Combine.7 Used for true discharge air sensing in both heating and cooling models.8 Clarksville Manufacturing has a no-return policy for this roof curb.9 For downflow use only. Can not be adapted for horizontal units.0 BAYABRD002B is required when ordering field installed accessories BAYDFPS005A or 006A, BAYTUBE008A or 009A and BAYLOAM023A or BAYVNOR002B.q Field or factory installed option.w Field installed accessory. Requires an economizer.e Interface allows a unit with ReliaTel™ Controls to communicate with Tracer 100, Tracker, VariTrac II, and is the prefered method of communication to Tracer Summit.r With ReliaTel™ controlled units only.* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.

Voyager™ Packaged Heat Pump withReliaTel™ Controls 12½ through 20Tons Accessories

Page 200: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PH-33 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Table PH-33-A — Downflow/Horizontal Supplementary Heaters:Model Power kW Nominal No.Number Supply Rating BTUH Stages Used With

AYDHTRK418A 460/3/60 18.0 61,400 1 WCD150B4,180B4AYDHTRK436A 460/3/60 36.0 122,900 2 WCD150B4,180B4AYDHTRK454A 460/3/60 54.0 184,300 2 WCD150B4,180B4

AYDHTRK318A 208/240/3/60 13.5/18.0 46,100/61,400 1 WCD150B3, 180B3AYDHTRK336A 208/240/3/60 27.0/36.0 92,200/122,900 2 WCD150B3, 180B3AYDHTRK354A 208/240/3/60 40.5/54.0 138,200/184,300 2 WCD150B3, 180B3

AYDHTRL336A 208/240/3/60 27.0/36.0 92,200/122,900 2 WCD240B3AYDHTRL354A 208/240/3/60 40.5/54.0 138,200/184,300 2 WCD240B3AYDHTRK372A 208/240/3/60 54.0/72.0 184,300/245,700 2 WCD240B3

AYDHTRL436A 460/3/60 36.0 122,900 2 WCD240B4AYDHTRL454A 460/3/60 54.0 184,300 2 WCD240B4AYDHTRK472A 460/3/60 72.0 245,700 2 WCD240B4

AYHHTRN318A 208/240/3/60 13.5/18.0 46,100/61,400 1 WCH150B3, 180B3AYHHTRP336A 208/240/3/60 27.0/36.0 92,200/122,900 2 WCH150B3, 180B3AYHHTRP354A 208/240/3/60 40.5/54.0 138,200/184,300 2 WCH150B3, 180B3

AYHHTRP418A 460/3/60 18.0 61,400 1 WCH180B4,150B4AYHHTRP436A 460/3/60 36.0 122,900 2 WCH180B4,150B4AYHHTRP454A 460/3/60 54.0 184,300 2 WCH180B4,150B4

AYHHTRN336A 208/240/3/60 27.0/36.0 92,200/122,900 2 WCH240B3AYHHTRN354A 208/240/3/60 40.5/54.0 138,200/184,300 2 WCH240B3AYHHTRN372A 208/240/3/60 54.0/72.0 184,300/245,700 2 WCH240B3

AYHHTRN436A 460/3/60 36.0 122,900 2 WCH240B4AYHHTRN454A 460/3/60 54.0 184,300 2 WCH240B4AYHHTRN472A 460/3/60 72.0 245,700 2 WCH240B4

AYDHTRKW18A 575/3/60 18.0 61,400 1 WCD120BW,180BWAYDHTRKW36A 575/3/60 36.0 122,900 2 WCD120BW,180BWAYDHTRKW54A 575/3/60 54.0 184,300 2 WCD120BW,180BW

AYDHTRLW36A 575/3/60 36.0 122,900 2 WCD240BWAYDHTRLW54A 575/3/60 54.0 184,300 2 WCD240BWAYDHTRKW72A 575/3/60 72.0 245,700 2 WCD240BW

AYHHTRNW18A 575/3/60 18.0 61,400 1 WCH150BW,180BWAYHHTRPW36A 575/3/60 36.0 122,900 2 WCH150BW,180BWAYHHTRPW54A 575/3/60 54.0 184,300 2 WCH150BW,180BW

AYHHTRNW36A 575/3/60 36.0 122,900 2 WCH240BWAYHHTRNW54A 575/3/60 54.0 184,300 2 WCH240BWAYHHTRNW72A 575/3/60 72.0 245,700 2 WCH240BW

Note: Unit with heater is single circuit/single point.

Voyager™ PackagedHeat Pump with MicroControls 12½ through 20 Tons

See ReliaTel™ and Micro Control features on PC-35 and PC-36.

Page 201: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PG-1 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Table PG-1-A — 2YCX- XL13c - Convertible Package Gas/Electric - R-22Cabinet

Model AFUE (%) Shipping Max Sound Dimensions (in.)Number Capacity SEER/EER HSPF Weight MCA Fuse Rating H x W x L2YCX – 208/230/1/602YCX3024A1040A 25,500 13.35/11.65 80 470 13.3 20 70 36 x 51 x 432YCX3024A1064A 25,500 13.35/11.65 80 481 13.3 20 70 36 x 51 x 432YCX3030A1040A 29,400 13.20/11.30 80 470 16.3 25 70 36 x 51 x 432YCX3030A1064A 29,400 13.20/11.30 80 481 16.3 25 70 36 x 51 x 432YCX3030A1075A 29,400 13.20/11.30 80 481 16.3 25 70 36 x 51 x 432YCX3036A1063A 35,200 13.00/11.20 80 479 23.0 35 72 36 x 51 x 432YCX3036A1075A 35,200 13.00/11.20 80 479 23.0 35 72 36 x 51 x 432YCX3036A1096A 35,200 13.00/11.20 80 485 23.0 35 72 36 x 51 x 432YCX3042A1064A 41,500 13.15/11.30 80 599 24.5 40 73 38 x 61 x 462YCX3042A1075A 41,500 13.15/11.30 80 599 24.5 40 73 38 x 61 x 462YCX3042A1096A 41,500 13.15/11.30 80 607 24.5 40 73 38 x 61 x 462YCX3048A1075A 48,000 13.30/11.25 80 656 29.0 45 73 38 x 61 x 462YCX3048A1096A 48,000 13.30/11.25 80 663 29.0 45 73 38 x 61 x 462YCX3048A1120A 48,000 13.30/11.25 80 669 29.0 45 73 38 x 61 x 462YCX3060A1096A 59,500 13.55/11.60 80 678 40.4 60 75 42 x 61 x 462YCX3060A1120A 59,500 13.55/11.60 80 684 40.4 60 75 42 x 61 x 46

• Architecturally integrated louvers andcorner guards deliver durable protection,extra safety, and great looks.

• Weather Beater Top contoured for greatappearance and reinforced for strength.

• Ultra quiet operation provides best-in-classperformance with barely noticeable soundlevels.

• Appliance grade finish of durable powderpaint baked on both sides of the panels.

• Exclusive Climatuff® high efficiencycompressor with internal overload protection.

• Aerospace ducted outdoor fan with a highefficiency motor for quiet and reliableoperation.

• Composite Vortica® blower provides betterairflow and less sound while using lessenergy.

• Spine Fin™ outdoor coil for long lastingperformance and durability.

• Right side electrical service for high and lowvoltage lines.

• Rugged steel basepan features deep drawnduct connections and emergency drains.

• Steeply sloped composite drainpan willempty fast and never rust.

• Ships in horizontal configuration andconverts quickly for downflow.

• Complete set of customized electricheaters designed for all models. Featuresa polarized plug for easy installation.

• Optional filter rack kits fit inside the unit.Available for 1" or 2" media.

• Non-bleed expansion valves on indoorand outdoor coils.

• Direct drive 2 and 3 speed indoor blowermotors.

• Pressure taps easily accessed andprotected inside compressor compart-ment.

• Easy access liquid line tap insidecompressor compartment.

• Standard operation to 55°F as manufac-tured.

• Low ambient cooling to 0°F with kit.• UL approved and listed.• 20 year heat exchanger, 10 year

compressor, 10 year outdoor coil, and5 year other parts limited warranty.(Residential Use Only)

• Optional extended warranty.

Package Gas/ElectricConvertible 2 through 5 Tons

For information on Roof Curbs and Roof Curb Adaptors,please refer to the Accessories/Information Tab.

Page 202: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PG-2Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Table PG-2-A — 4YCX - XL13c - Convertible Package Gas/Electric - R-410ACabinet

Model AFUE (%) Shipping Max Sound Dimensions (in.)Number Capacity SEER/EER HSPF Weight MCA Fuse Rating H x W x L4YCX – 208/230/1/604YCX3018A1040A 18,800 13.55/11.15 80 471 10.1 15 69 36 x 51 x 434YCX3036A1064A 36,400 13.15/11.05 80 488 23.6 35 71 36 x 51 x 434YCX3036A1075A 36,400 13.15/11.05 80 488 23.6 35 71 36 x 51 x 434YCX3036A1096A 36,400 13.15/11.05 80 493 23.6 35 71 36 x 51 x 434YCX3048A1075A 46,500 13.05/11.00 80 645 31.5 50 73 38 x 61 x 464YCX3048A1096A 46,500 13.05/11.00 80 653 31.5 50 73 38 x 61 x 464YCX3048A1120A 46,500 13.05/11.00 80 659 31.5 50 73 38 x 61 x 464YCX3060A1096A 60,000 13.40/10.95 80 678 43.3 60 75 40 x 61 x 464YCX3060A1120A 60,000 13.40/10.95 80 684 43.3 60 75 40 x 61 x 464YCX – 208/230/3/604YCX3036A3064A 36,400 13.15/11.05 80 488 18.5 30 71 36 x 51 x 434YCX3036A3075A 36,400 13.15/11.05 80 488 18.5 30 71 36 x 51 x 434YCX3036A3096A 36,400 13.15/11.05 80 493 18.5 30 71 36 x 51 x 434YCX3048A3075A 46,500 13.05/11.00 80 645 24.0 35 73 38 x 61 x 464YCX3048A3096A 46,500 13.05/11.00 80 653 24.0 35 73 38 x 61 x 464YCX3048A3120A 46,500 13.05/11.00 80 659 24.0 35 73 38 x 61 x 464YCX3060A3096A 60,000 13.40/10.95 80 678 31.5 50 75 40 x 61 x 464YCX3060A3120A 60,000 13.40/10.95 80 684 31.5 50 75 40 x 61 x 464YCX – 460/3/604YCX3036A4064A 36,400 13.15/11.05 80 448 8.7 15 71 36 x 51 x 434YCX3036A4075A 36,400 13.15/11.05 80 448 8.7 15 71 36 x 51 x 434YCX3036A4096A 36,400 13.15/11.05 80 493 8.7 15 71 36 x 51 x 434YCX3048A4075A 46,500 13.05/11.00 80 645 11.7 15 73 38 x 61 x 464YCX3048A4096A 46,500 13.05/11.00 80 653 11.7 15 73 38 x 61 x 464YCX3048A4120A 46,500 13.05/11.00 80 659 11.7 15 73 38 x 61 x 464YCX3060A4096A 60,000 13.40/10.95 80 678 19.3 25 75 40 x 61 x 464YCX3060A4120A 60,000 13.40/10.95 80 684 19.3 25 75 40 x 61 x 46

• Architecturally integrated louvers andcorner guards deliver durable protection,extra safety, and great looks.

• Ultra quiet operation provides best-in-classperformance with barely noticeable soundlevels.

• Appliance grade finish of durable powderpaint baked on both sides of the panels.

• Exclusive Climatuff® high efficiencycompressor with internal overloadprotection.

• Aerospace ducted outdoor fan with a highefficiency motor for quiet and reliableoperation.

• Composite Vortica® blower providesbetter airflow and less sound while usingless energy.

• Spine Fin™ outdoor coil for long lastingperformance and durability.

• Right side electrical service for high andlow voltage lines.

• Rugged steel basepan features deepdrawn duct connections and emergencydrains.

• Steeply sloped composite drainpan willempty fast and never rust.

• Ships in horizontal configuration andconverts quickly for downflow.

• Complete set of customized electricheaters designed for all models. Featuresa polarized plug for easy installation.

• Optional filter rack kits fit inside the unit.Available for 1" or 2" media.

• Non-bleed expansion valves on indoorand outdoor coils.

• Direct drive 2 and 3 speed indoor blowermotors.

• Pressure taps easily accessed andprotected inside compressor compart-ment.

• Easy access liquid line tap insidecompressor compartment.

• Standard operation to 55°F as manufac-tured.

• Low ambient cooling to 0°F with kit.• UL approved and listed.• 20 year heat exchanger, 10 year

compressor, 10 year outdoor coil, and5 year other parts limited warranty.(Residential Use Only)

• Optional extended warranty.

Package Gas/ElectricConvertible 1½ through 5 Tons

For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.

Page 203: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PG-3 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Package Gas/ElectricConvertible 1½ through 5 Tons

2/4YCX3018A through 2/4YCX3036A

For information on Roof Curbs andRoof Curb Adaptors, please refer tothe Accessories/Information Tab.

Page 204: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PG-4Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Package Gas/ElectricConvertible 1½ through 5 Tons

2/4YCX3018A through 2/4YCX3036A

For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.

Page 205: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PG-5 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Package Gas/ElectricConvertible 1½ through 5 Tons

2/4YCX3042A through 2/4YCX3060A

For information on Roof Curbs andRoof Curb Adaptors, please refer tothe Accessories/Information Tab.

Page 206: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PG-6Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Package Gas/ElectricConvertible 1½ through 5 Tons

2/4YCX3042A through 2/4YCX3060A

For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.

Page 207: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PG-7 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Table PG-7-A — 2YCC - XB13c - Convertible Package Gas/Electric - R-22Cabinet

Model AFUE (%) Shipping Max Sound Dimensions (in.)Number Capacity SEER/EER HSPF Weight MCA Fuse Rating H x W x L2YCC – 208/230/1/602YCC3024A1040A 23,000 13.00/11.00 80 470 13.3 20 74 36 x 49 x 412YCC3024A1064A 23,000 13.00/11.00 80 481 13.3 20 74 36 x 49 x 412YCC3030A1040A 28,000 13.00/11.00 80 470 16.3 25 74 36 x 49 x 412YCC3030A1064A 28,000 13.00/11.00 80 481 16.3 25 74 36 x 49 x 412YCC3030A1075A 28,000 13.00/11.00 79.4 481 16.3 25 74 36 x 49 x 412YCC3036A1064A 35,000 13.00/11.00 80 479 23.0 35 76 36 x 49 x 412YCC3036A1075A 35,000 13.00/11.00 80 479 23.0 35 76 36 x 49 x 412YCC3036A1096A 35,000 13.00/11.00 80 485 23.0 35 76 36 x 49 x 412YCC3042A1064A 40,000 13.00/11.00 80 599 24.5 40 78 38 x 59 x 442YCC3042A1075A 40,000 13.00/11.00 80 599 24.5 40 78 38 x 59 x 442YCC3042A1096A 40,000 12.20/11.00 80 607 24.5 40 78 38 x 59 x 442YCC3048A1075A 47,000 13.00/11.00 80 656 29.0 45 77 38 x 59 x 442YCC3048A1096A 47,000 13.00/11.00 80 663 29.0 45 77 38 x 59 x 442YCC3048A1120A 47,000 13.00/11.00 80 669 29.0 45 77 38 x 59 x 442YCC3060A1096A 58,000 13.00/11.00 80 678 40.4 60 76 42 x 59 x 442YCC3060A1120A 58,000 13.00/11.00 80 684 40.4 60 76 42 x 59 x 44

• All steel louvers and cabinet for rugged,long lasting protection.

• Stainless steel burners and heat exchangerfor extra long life and safety.

• Quiet operation delivers great in-homecomfort with minimal sound.

• Weather Beater Top contoured for greatappearance and reinforced for strength.

• Appliance grade finish of durable powderpaint baked on both sides of the panels.

• Exclusive Climatuff® high efficiencycompressor with internal overloadprotection.

• High efficiency outdoor fan motor for quietand reliable operation.

• Composite Vortica® blower providesbetter airflow and less sound while usingless energy.

• Spine Fin™ outdoor coil for long lastingperformance and durability.

• Right side electrical service for high andlow voltage lines.

• Rugged steel basepan features deepdrawn duct connections and emergencydrains.

• Steeply sloped composite drainpan willempty fast and never rust.

• Ships in horizontal configuration andconverts quickly for downflow.

• Complete set of customized electricheaters designed for all models. Featuresa polarized plug for easy installation.

• Optional filter rack kits fit inside the unit.Available for 1" or 2" media.

• Non-bleed expansion valves on indoorand outdoor coils.

• Direct drive 2 and 3 speed indoor blowermotors.

• Pressure taps easily accessed andprotected inside compressor compart-ment.

• Easy access liquid line tap insidecompressor compartment.

• Standard operation to 55°F as manufac-tured.

• Low ambient cooling to 0°F with kit.• UL approved and listed.• 10 year heat exchanger, 5 year

compressor and coil and 5 year otherparts limited warranty.(Residential Use Only)

• Optional extended warranty.

Package Gas/ElectricConvertible 2 through 5 Tons

For information on Roof Curbs and Roof Curb Adaptors,please refer to the Accessories/Information Tab.

Page 208: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PG-8Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Table PG-8-A — 4YCC - XB13c - Convertible Package Gas/Electric - R-410ACabinet

Model AFUE (%) Shipping Max Sound Dimensions (in.)Number Capacity SEER/EER HSPF Weight MCA Fuse Rating H x W x L4YCC – 208/230/1/604YCC3018A1040A 18,000 13.00/11.00 79.8 471 10.1 15 74 36 x 49 x 414YCC3036A1064A 35,000 13.00/11.00 80 488 23.6 35 75 36 x 49 x 414YCC3036A1075A 35,000 13.00/11.00 80 488 23.6 35 75 36 x 49 x 414YCC3036A1096A 35,000 13.00/11.00 80 493 23.6 35 75 36 x 49 x 414YCC3048A1075A 46,500 13.00/11.00 80 645 31.5 50 80 38 x 59 x 444YCC3048A1096A 46,500 13.00/11.00 80 653 31.5 50 80 38 x 59 x 444YCC3048A1120A 46,500 13.00/11.00 80 659 31.5 50 80 38 x 59 x 444YCC3060A1096A 58,000 13.00/10.95 80 670 43.3 60 79 40 x 59 x 444YCC3060A1120A 58,000 13.00/10.95 80 676 43.3 60 79 40 x 59 x 444YCC – 208/230/3/604YCC3036A3064A 35,000 13.00/11.00 80 488 18.5 30 75 36 x 49 x 414YCC3036A3075A 35,000 13.00/11.00 80 488 18.5 30 75 36 x 49 x 414YCC3036A3096A 35,000 13.00/11.00 80 493 18.5 30 75 36 x 49 x 414YCC3048A3075A 46,500 13.00/11.00 80 645 24.0 35 80 38 x 59 x 444YCC3048A3096A 46,500 13.00/11.00 80 653 24.0 35 80 38 x 59 x 444YCC3048A3120A 46,500 13.00/11.00 80 659 24.0 35 80 38 x 59 x 444YCC3060A3096A 58,000 13.00/10.95 80 670 31.5 50 79 40 x 59 x 444YCC3060A3120A 58,000 13.00/10.95 80 676 31.5 50 79 40 x 59 x 444YCC – 460/3/604YCC3036A4064A 35,000 13.00/11.00 80 488 8.7 15 75 36 x 49 x 414YCC3036A4075A 35,000 13.00/11.00 80 488 8.7 15 75 36 x 49 x 414YCC3036A4096A 35,000 13.00/11.00 80 493 8.7 15 75 36 x 49 x 414YCC3048A4075A 46,500 13.00/11.00 80 645 11.7 15 80 38 x 59 x 444YCC3048A4096A 46,500 13.00/11.00 80 653 11.7 15 80 38 x 59 x 444YCC3048A4120A 46,500 13.00/11.00 80 659 11.7 15 80 38 x 59 x 444YCC3060A4096A 58,000 13.00/10.95 80 678 19.3 25 79 40 x 59 x 444YCC3060A4120A 58,000 13.00/10.95 80 684 19.3 25 79 40 x 59 x 44

• All steel louvers and cabinet for rugged,long lasting protection.

• Stainless steel burners and heat exchangerfor extra long life and safety.

• Quiet operation delivers great in-homecomfort with minimal sound.

• Weather Beater Top contoured for greatappearance and reinforced for strength.

• Appliance grade finish of durable powderpaint baked on both sides of the panels.

• Exclusive Climatuff® high efficiencycompressor with internal overloadprotection.

• High efficiency outdoor fan motor for quietand reliable operation.

• Composite Vortica® blower providesbetter airflow and less sound while usingless energy.

• Spine Fin™ outdoor coil for long lastingperformance and durability.

• Right side electrical service for high andlow voltage lines.

• Rugged steel basepan features deepdrawn duct connections and emergencydrains.

• Steeply sloped composite drainpan willempty fast and never rust.

• Ships in horizontal configuration andconverts quickly for downflow.

Package Gas/ElectricConvertible 1½ through 5 Tons

• Complete set of customized electricheaters designed for all models.Features a polarized plug for easyinstallation.

• Optional filter rack kits fit inside the unit.Available for 1" or 2" media.

• Non-bleed expansion valves on indoorand outdoor coils.

• Direct drive 2 and 3 speed indoor blowermotors.

• Pressure taps easily accessed andprotected inside compressor compart-ment.

• Easy access liquid line tap insidecompressor compartment.

• Standard operation to 55°F as manufac-tured.

• Low ambient cooling to 0°F with kit.• UL approved and listed.• 10 year heat exchanger, 5 year

compressor and coil and 5 year otherparts limited warranty.(Residential Use Only)

• Optional extended warranty.

For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.

Page 209: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PG-9 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

2/4YCC3018A through 2/4YCC3036A

Package Gas/ElectricConvertible 1½ through 5 Tons

For information on Roof Curbs andRoof Curb Adaptors, please refer tothe Accessories/Information Tab.

Page 210: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PG-10Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

2/4YCC3018A through 2/4YCC3036A

Package Gas/ElectricConvertible 1½ through 5 Tons

For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.

Page 211: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PG-11 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

2/4YCC3042A through 2/4YCC3060A

Package Gas/ElectricConvertible 1½ through 5 Tons

For information on Roof Curbs andRoof Curb Adaptors, please refer tothe Accessories/Information Tab.

Page 212: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PG-12Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

2/4YCC3042A through 2/4YCC3060A

Package Gas/ElectricConvertible 1½ through 5 Tons

For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.

Page 213: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PG-13 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Package Gas/ElectricConvertible 1½ through 5 Tons

2YCX 4YCX 2YCC 4YCCTable PG-13-A — Accessories 2-5 1½-5 2-5 1½-5BAYADAP050A ...... Adapter Curb (Cabinet A/B) .................................................................................. 1½-3 1½-3 1½-3 1½-3BAYADAP051A ...... Adapter Curb (Cabinet C) ..................................................................................... 1½-3 1½-3 1½-3 1½-3BAYADAP052A ...... Adapter Curb (Cabinet A/B) .................................................................................. 3½-5 3½-5 3½-5 3½-5BAYADAP053A ...... Adapter Curb (Cabinet C) ..................................................................................... 3½-5 3½-5 3½-5 3½-5BAYADAP054A ...... Adapter Curb (Cabinet D) ..................................................................................... 3½-5 3½-5 3½-5 3½-5BAYCCHT101A ..... Crankcase Heater (230v) ..................................................................................... 2-2½, 3½-4 1½ 2-2½, 3½-4 1½BAYCCHT102A ..... Crankcase Heater (230v) ..................................................................................... 3 3,4,5 3 3,4,5BAYCCHT104A ..... Crankcase Heater (460v) ..................................................................................... — 3,4,5 — 3,4,5BAYCOVR112A ..... 12" Duct Shroud (Covers Horizontal Ducts)0 ....................................................... 1½-5 1½-5 1½-5 1½-5BAYCOVR118A ..... 18" Duct Shroud (Covers Horizontal Ducts)0 ....................................................... 1½-5 1½-5 1½-5 1½-5BAYCURB050A ..... Flat Roof Curb (Insulated)5 .................................................................................. 1½- 3 1½- 3 1½- 3 1½- 3BAYCURB051A ..... Flat Roof Curb (Insulated)6 .................................................................................. 3½-5 3½-5 3½-5 3½-5BAYDMPR101A ..... Motorized Fresh Air Damper14 ........................................................................... 1½- 3 1½- 3 1½- 3 1½- 3BAYDMPR102A ..... Motorized Fresh Air Damper14 ........................................................................... 3½-5 3½-5 3½-5 3½-5BAYECON101A ..... Economizer with Barometric Relief1347 ............................................................ 1½- 3 1½- 3 1½- 3 1½- 3BAYECON102A ..... Economizer with Barometric Relief1347 ............................................................ 3½-5 3½-5 3½-5 3½-5BAYECON200A ..... Economizer (Horizontal)137 ............................................................................... 1½- 3 1½- 3 1½- 3 1½- 3BAYECON201A ..... Economizer (Horizontal)137 ............................................................................... 3 ½-5 3 ½-5 3 ½-5 3 ½-5BAYENTH100A ..... Enthalpy Control Kit3 ........................................................................................... ✔ ✔ ✔ ✔BAYEXMK001A ..... Extreme Conditions Mounting Kit (Used on BAYCURB & BAYADAP) ................... ✔ ✔ ✔ ✔BAYEXMK002A ..... Extreme Conditions Mounting Kit (Used on BAYUTIL) .......................................... ✔ ✔ ✔ ✔BAYEXMK003A ..... Extreme Conditions Mounting Kit (Used on Slab Mounts) ..................................... ✔ ✔ ✔ ✔BAYFLTR101A ....... 1-2" Filter Frame (20x20 filter not included)1 ........................................................ 1½- 3 1½- 3 1½- 3 1½- 3BAYFLTR201A ....... 1-2" Filter Frame (20x20, 20x18 filters not included)1 .......................................... 3½-5 3½-5 3½-5 3½-5BAYLIFT002BA ..... Lifting Lug Kit ....................................................................................................... ✔ ✔ ✔ ✔BAYLOAM011A ..... Evaporator Defrost Control Kit .............................................................................. ✔ ✔ ✔ ✔BAYLOAM105A ..... Head Pressure Control ......................................................................................... ✔ ✔ ✔ ✔BAYLPKT100A ...... LP Conversion Kit ................................................................................................ 40K,120K 40K,120K 40K,120K 40K,120KBAYLPKT101A ...... LP Conversion Kit ................................................................................................ 64K, 96K 64K, 96K 64K, 96K 64K, 96KBAYLPKT102A ...... LP Conversion Kit ................................................................................................ 75K 75K 75K 75KBAYOSAH001A ..... Manual Fresh Air Damper1 .................................................................................. 1½- 3 1½- 3 1½- 3 1½- 3BAYOSAH002A ..... Manual Fresh Air Damper1 .................................................................................. 3½-5 3½-5 3½-5 3½-5BAYQSTK301A ..... Quick Start Kit ...................................................................................................... ✔ ✔ ✔ ✔BAYSQRD001A ..... 16" Round Duct Adapter9 .................................................................................... 1½- 3 1½- 3 1½- 3 1½- 3BAYSQRD002A ..... 18" Round Duct Adapter9 .................................................................................... 1½-5 1½-5 1½-5 1½-5BAYUTIL101A ....... Roof Curb Utility Extension Kit .............................................................................. 1½- 3 1½- 3 1½- 3 1½- 3BAYUTIL102A ....... Roof Curb Utility Extension Kit .............................................................................. 3½-5 3½-5 3½-5 3½-51 Must use filter frame when economizer/fresh air kit is used.2 Ships knocked down.3 Dry bulb control standard with economizer.4 Downflow Only.5 Full perimeter curb for 2/4YC*3018-036A.6 Full perimeter curb for 2/4YC*3042-060A.7 2-Stage thermostat provides additional energy savings if simultaneous economizer and compressor operation is expected.8 Do not use with programmable thermostats.9 It is the responsibility of the installing dealer to properly size the ductwork for each specific application.0 BAYCOVR112,118A will not cover BAYSQRD002A applications

For information on Roof Curbs and Roof Curb Adaptors,please refer to the Accessories/Information Tab.

Page 214: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PG-14Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

PHASED OUT

YCX – XL 1200YCZ – XL 1600YCY – XL 1400

Table PG-14-A — YCZ – XL 1600 Convertible Package Gas/ElectricCooling Heating Output Cabinet Supply/Return Supply/Return Shipping

Unit Capacity Capacity Dimensions (in.) Downflow Horizontal Weight Max. SoundModel No. SEER/EER* (Btuh) (Btuh) AFUE% H x W x L W x L H x W (Ibs.) MCA* Fuse* Rating Comp.

YCZ – 208-230/1/60 Stage 1 - Stage 2YCZ036F1M0B 16.05/12.00 36,000 45,000 – 57,000 80 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 588 27.1 40 80 R1/ 2YCZ050F1H0A 16.00/11.60 51,000 73,000 – 95,500 80 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 693 32 40 82 R1YCZ060F1M0B 15.20/11.00 59,000 72,000 – 96,000 80 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 723 43.5 70 84 R1 /2YCZ – 208-230/3/60 Stage 1 - Stage 2YCZ036F3M0B 16.05/12.00 36,000 45,000 – 57,000 80 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 588 19.6 30 80 R1/ 2YCZ050F3H0A 16.00/11.60 51,000 73,000 – 95,500 80 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 693 26 30 82 R1YCZ060F3M0B 15.20/11.00 59,000 72,000 – 96,000 80 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 723 30.9 45 84 R1/ 2

YCZ – 460/3/60 Stage 1 - Stage 2YCZ036F4M0A 15.60 36,000 45,000 – 57,000 80 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 613 11.4 15 80 R1/ 2YCZ050F4H0A 14.00 51,000 73,000 – 95,500 80 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 718 15.1 20 82 R1YCZ060F4M0A 14.85 59,000 72,000 – 96,000 80 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 748 20.3 30 82 R1/ 2

Table PG-14-B — YCY – XL 1400 Convertible Package Gas/ElectricCooling Heating Output Cabinet Supply/Return Supply/Return Shipping

Unit Capacity Capacity Dimensions (in.) Downflow Horizontal Weight Max. SoundModel No. SEER/EER* (Btuh) (Btuh) AFUE% H x W x L W x L H x W (Ibs.) MCA* Fuse* Rating Comp.

YCY – 208-230/1/60 Stage 1 - Stage 2YCY024G1L0A 14.00/12.00 24,000 30,000 – 37,000 80 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 444 15.9 25 80 R1YCY024G1M0A 14.00/12.00 24,000 44,000 – 53,000 80 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 455 15.9 25 80 R1YCY030G1L0A 13.00/11.00 30,600 31,000 – 38,000 80 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 474 21.4 30 80 R2YCY030G1M0A 13.00/11.00 30,600 44,000 – 55,000 80 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 485 21.4 30 80 R2YCY036G1M0A 14.00/12.00 36,000 45,000 – 57,000 80 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 508 24.8 40 80 R2YCY036G1H0A 14.00/12.00 36,000 61,000 – 72,000 80 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 513 24.8 40 80 R2YCY042G1M0A 14.00/11.70 41,500 65,000 – 78,000 80 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 513 26.7 40 80 R2YCY048G1H0A 14.40/12.20 49,000 73,000 – 95,500 80 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 639 32.7 45 84 R2YCY060G1M0A 13.00/11.00 61,000 72,000 – 96,000 80 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 659 46.8 70 84 S

Table PG-14-C — YCX – XL 1200 Convertible Package Gas/ElectricCooling Heating Output Cabinet Supply/Return Supply/Return Shipping

Unit Capacity Capacity Dimensions (in.) Downflow Horizontal Weight Max. SoundModel No. SEER/EER* (Btuh) (Btuh) AFUE% H x W x L W x L H x W (Ibs.) MCA* Fuse* Rating Comp.

YCX – 208-230/1/60YCX024G1L0B 12.00/10.50 24,500 30,000-38,000 80 25 x 36 x 56 (A/B) 10 x 171/2 189/16 x 111/16 380 15.6 25 80 R1YCX024G1M0B 12.00/10.50 24,500 46,000-57,000 80 29 x 36 x 56 (A/B) 10 x 171/2 189/16 x 111/16 397 15.6 25 80 R1YCX030G1L0A 12.05/10.90 30,600 30,000-38,000 80 29 x 36 x 56 (B) 10 x 171/2 189/16x 111/16 396 20.3 30 80 SYCX030G1M0A 12.05/10.90 30,600 44,000-56,000 80 29 x 36 x 56 (B) 10 x 171/2 189/16 x 111/16 403 20.3 30 80 SYCX036G1L0A 12.05/10.50 37,000 32,000-39,000 80 29 x 36 x 56 (B/C) 10 x 171/2 189/16 x 111/16 412 24.0 40 80 SYCX036G1M0A 12.05/10.50 37,000 48,000-57,000 80 29 x 36 x 56 (B/C) 10 x 171/2 189/16 x 111/16 419 24.0 40 80 SYCX036G1H0A 12.05/10.50 37,000 60,000-76,000 80 29 x 36 x 64 (B/C) 10 x 171/2 189/16 x 111/16 440 24.0 40 80 SYCX042G1M0A 12.05/10.55 43,000 60,000-76,000 80 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 454 27.9 45 80 SYCX048G1H0A 12.50/11.45 48,000 78,000-95,000 80 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 582 31.1 45 84 SYCX060G1M0A 12.05/10.55 61,500 80,000-97,000 80 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 609 43.7 70 84 S

1 Low/High output - Unit ships standard high heat configuration. Low-fire operation requires optional BAYLOFR001-007 kit.* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.Compressor Types are: R1 = Reciprocating One Cylinder, R2 = Reciprocating Two Cylinder, S = Scroll

Package Gas/ElectricConvertible 1½ through 5 Tons

For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.

Page 215: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PG-15 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

PHASED OUT

PHASED OUT

Table PG-15-A — YCX – XL 1200 Convertible Package Gas/ElectricCooling Heating Output11111 Cabinet Supply/Return Supply/Return Shipping

Unit Capacity Capacity Dimensions (in.) Downflow Horizontal Weight Max. SoundModel No. SEER/EER* (Btuh) (Btuh) AFUE% H x W x L W x L H x W (Ibs.) MCA* Fuse* Rating Comp.

YCX – 208-230/3/60YCX036G3L0A 12.05/10.5 37,000 32,000-39,000 80 29 x 36 x 56 (B/C) 10 x 171/2 189/16 x 111/16 412 17.4 25 80 SYCX036G3M0A 12.05/10.50 37,000 48,000-57,000 80 29 x 36 x 56 (B/C) 10 x 171/2 189/16 x 111/16 419 17.4 25 80 SYCX036G3H0A 12.05/10.50 37,000 60,000-76,000 80 29 x 36 x 64 (B/C) 10 x 171/2 189/16 x 111/16 440 17.4 25 80 SYCX042G3M0A 12.05/10.55 43,000 60,000-76,000 80 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 454 19.9 30 80 SYCX048G3H0A 12.50/11.45 48,000 78,000-95,000 80 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 582 24.5 35 84 SYCX060G3M0A 12.05/10.55 61,500 80,000-97,000 80 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 609 30.6 45 84 SYCX – 460/3/60YCX036G4H0A 12.05/10.50 37,000 60,000-76,000 80 29 x 36 x 64 (B/C) 10 x 171/2 189/16 x 111/16 440 10.0 15 80 SYCX048G4H0A 12.50/11.45 48,000 78,000-95,000 80 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 582 15.4 20 84 SYCX060G4M0A 12.05/10.55 61,500 80,000-97,000 80 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 609 15.1 20 84 S

Table PG-15-B — YCP – XE 1200 Convertible Package Gas/ElectricCooling Heating Output11111 Cabinet Supply/Return Supply/Return Shipping

Unit Capacity Capacity Dimensions (in.) Downflow Horizontal Weight Max. SoundModel No. SEER/EER* (Btuh) (Btuh) AFUE% H x W x L W x L H x W (Ibs.) MCA* Fuse* Rating Comp.

YCP – 208-230/1/60YCP024F1L0B 12.00/10.50 24,200 30,000 – 38,000 80 25 x 36 x 56 (A/B) 10 x 171/2 189/16 x 111/16 380 14.6 20 80 R1YCP024F1M0B 12.00/10.50 24,000 46,000 – 57,000 80 29 x 36 x 56 (A/B) 10 x 171/2 189/16 x 111/16 397 14.8 20 80 R1YCP030F1L0A 12.00/10.90 30,000 30,000 – 38,000 80 29 x 36 x 56 (A/B) 10 x 171/2 189/16 x 111/16 396 21.2 30 80 SYCP030F1M0A 12.00/10.90 30,000 44,000 – 56,000 80 29 x 36 x 56 (A/B) 10 x 171/2 189/16 x 111/16 403 21.2 30 80 SYCP036F1L0A 12.00/10.50 36,000 32,000 – 39,000 80 29 x 36 x 56 (B/C) 10 x 171/2 189/16 x 111/16 412 24.4 40 80 SYCP036F1M0A 12.0010.50 36,000 48,000 – 57,000 80 29 x 36 x 56 (B/C) 10 x 171/2 189/16 x 111/16 419 24.4 40 80 SYCP036F1H0A 12.00/10.50 36,000 60,000 – 76,000 80 29 x 36 x 64 (B/C) 10 x 171/2 189/16 x 111/16 440 24.4 40 80 SYCP042F1M0A 12.00/10.55 42,000 60,000 – 76,000 80 29 x 36 x 64 (B/C) 10 x 171/2 189/16 x 111/16 454 26.8 40 80 SYCP048F1H0A 12.20/11.45 47,000 78,000 – 95,000 80 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 582 31.9 50 84 SYCP060F1M0A 12.00/10.55 60,000 80,000 – 97,000 80 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 609 45.0 70 84 SYCP – 208-230/3/60YCP036F3L0A 12.00/10.50 36,000 32,000 – 39,000 80 29 x 36 x 56 (B/C) 10 x 171/2 189/16 x 111/16 412 17.4 25 80 SYCP036F3M0A 12.00/10.50 36,000 48,000 – 57,000 80 29 x 36 x 56 (B/C) 10 x 171/2 189/16 x 111/16 419 17.4 25 80 SYCP036F3H0A 12.00/10.50 36,000 60,000 – 76,000 80 29 x 36 x 64 (B/C) 10 x 171/2 189/16 x 111/16 440 17.4 25 80 SYCP042F3M0A 12.00/10.55 42,000 60,000 – 76,000 80 29 x 36 x 64 (B/C) 10 x 171/2 189/16 x 111/16 454 19.9 30 80 SYCP048F3H0A 12.20/11.45 47,000 78,000 – 95,000 80 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 582 24.5 35 84 SYCP060F3M0A 12.00/10.55 60,000 80,000 – 97,000 80 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 609 30.6 45 84 SYCP – 460/3/60YCP036F4H0A 12.00/10.50 36,000 60,000 – 76,000 80 29 x 36 x 64 (B/C) 10 x 171/2 189/16 x 111/16 440 10.0 15 80 SYCP048F4H0A 12.20/11.45 47,000 78,000 – 95,000 80 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 582 15.4 20 84 SYCP060F4M0A 12.00/10.55 60,000 80,000 – 97,000 80 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 609 15.1 20 84 S

1 Low/High output - Unit ships standard high heat configuration. Low-fire operation requires optional BAYLOFR001-007 kit.* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.Compressor Types are: R1 = Reciprocating One Cylinder, R2 = Reciprocating Two Cylinder, S = Scroll

YCP – XE 1200YCX – XL 1200

Package Gas/ElectricConvertible 2 through 5 Tons

For information on Roof Curbs and Roof Curb Adaptors,please refer to the Accessories/Information Tab.

Page 216: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PG-16Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

PHASED OUT

Table PG-16-A —YCC – XE 1000 Convertible Package Gas/ElectricCooling Heating Output11111 Cabinet Supply/Return Supply/Return Shipping

Unit Capacity Capacity Dimensions (in.) Downflow Horizontal Weight Max. SoundModel No. SEER/EER* (Btuh) (Btuh) AFUE% H x W x L W x L H x W (Ibs.) MCA* Fuse* Rating Comp.

YCC – 208-230/1/60YCC018F1L0B 10.00/9.35 18,000 32,000-40,000 78 25 x 36 x 55 (A) 10 x 171/2 189/16 x 111/16 341 13.2 20 80 R1YCC024F1L0B 10.00/9.10 23,400 32,000-40,000 78 25 x 36 x 55 (A) 10 x 171/2 189/16 x 111/16 350 15.7 25 80 R1YCC030F1L0B 10.00/9.20 29,200 32,000-40,000 78 25 x 36 x 55 (A/B) 10 x 171/2 189/16 x 111/16 398 20.1 30 80 R1YCC030F1M0B 10.00/9.20 29,800 48,000-60,000 78 29 x 36 x 55 (A/B) 10 x 171/2 189/16 x 111/16 398 21.3 35 80 R1YCC036F1L0B 10.00/8.75 35,200 32,000-40,000 78 29 x 36 x 55 (B/C) 10 x 171/2 189/16 x 111/16 420 25.2 40 80 R1/2YCC036F1M0B 10.00/8.75 35,200 48,000-60,000 78 29 x 36 x 55 (B/C) 10 x 171/2 189/16 x 111/16 426 25.2 40 80 R1/2YCC036F1H0B 10.00/8.75 35,200 64,000-80,000 78 29 x 36 x 63 (B/C) 10 x 171/2 189/16 x 111/16 454 25.2 40 80 R1/2YCC042F1M0B 10.00/9.50 42,000 64,000-80,000 78 29 x 36 x 63 (C) 10 x 171/2 189/16 x 111/16 454 30.2 50 80 R2YCC048F1M0B 10.00/9.25 46,500 64,000-80,000 78 29 x 36 x 63 (C/D) 10 x 171/2 189/16 x 111/16 461 33 50 80 R2YCC048F1H0B 10.00/9.25 48,000 80,000-100,000 78 33 x 45 x 64 (C/D) 14 x 20 211/16 x 151/16 576 34.4 50 84 R2YCC060F1M0B 10.00/9.20 60,000 80,000-100,000 78 33 x 45 x 64 (D) 14 x 20 211/16 x 151/16 604 43.9 70 84 R2

YCC – 208-230/3/60 - LIMITED AVAILABILITY 3 PHASE ONLY, 2006.YCC036F3L0B 10.00/8.75 35,400 32,000-40,000 78 29 x 36 x 55 (B/C) 10 x 171/2 189/16 x 111/16 420 18 25 80 R1/2YCC036F3M0B 10.00/8.75 35,400 48,000-60,000 78 29 x 36 x 55 (B/C) 10 x 171/2 189/16 x 111/16 426 18 25 80 R1/2YCC036F3H0B 10.008.75 35,400 64,000-80,000 78 29 x 36 x 63 (B/C) 10 x 171/2 189/16 x 111/16 454 18 25 80 R1/2YCC042F3M0B 10.00/9.50 42,000 64,000-80,000 78 29 x 36 x 63 (C) 10 x 171/2 189/16 x 111/16 454 22 35 80 R2YCC048F3M0B 10.00/9.25 46,500 64,000-80,000 78 29 x 36 x 63 (C/D) 10 x 171/2 189/16 x 111/16 461 24.8 40 84 R2YCC048F3H0B 10.00/9.25 48,000 80,000-100,000 78 33 x 45 x 64 (C/D) 14 x 20 211/16 x 151/16 576 26.8 40 84 R2YCC060F3M0B 10.00/9.20 60,000 80,000-100,000 78 33 x 45 x 64 (D) 14 x 20 211/16 x 151/16 604 31 45 84 R2YCC – 460/3/60 - LIMITED AVAILABILITY 3 PHASE ONLY, 2006.YCC036F4H0B 10.00/8.75 35,400 64,000-80,000 78 29 x 36 x 63 (B/C) 10 x 171/2 189/16 x 111/16 454 8 15 80 R1/2YCC048F4H0B 10.00/9.25 48,000 80,000-100,000 78 33 x 45 x 64 (C/D) 14 x 20 211/16 x 151/16 576 12.2 15 84 R2YCC060F4M0B 10.00/9.20 60,000 80,000-100,000 78 33 x 45 x 64 (D) 14 x 20 211/16 x 151/16 604 15.6 25 84 R2

1 Low/High output - Unit ships standard high heat configuration. Low-fire operation requires optional BAYLOFR001-007 kit.* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.Compressor Types are: R1 = Reciprocating One Cylinder, R2 = Reciprocating Two Cylinder, S = Scroll

Package Gas/ElectricConvertible 1½ through 5 Tons

YCC – XE 1000

For information on Roof Curbs and Roof Curb Adaptors,please refer to the Accessories/Information Tab.

Page 217: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PG-17 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

PH

AS

ED

OU

T

PH

AS

ED

OU

T

Package Gas/ElectricConvertible 1½ through 5 Tons

YCZ YCY-G YCX-G YCP-F YCC-FTable PG-17-A — Features 3-5 Ton 2-5 Ton 2-5 Ton 2-5 Ton 11/2-5 Ton• Climatuff® Compressor (2) ........................................................................................................ ✔ — — — —• Climatuff® Compressor (1) ........................................................................................................ — ✔ ✔ ✔ ✔• Coil Sav’RTM guard ...................................................................................................................... ✔ ✔ ✔ — —• Comfort "R"™ mode option ....................................................................................................... ✔ ✔ — — —• Aluminized steel tubular heat exchanger ..................................................................................... ✔ ✔ ✔ ✔ ✔• Direct spark ignition ..................................................................................................................... ✔ ✔ ✔ ✔ ✔• Dual firing rates (w/optional accessory) ...................................................................................... — — ✔ ✔ ✔• GE ECM variable speed fan ........................................................................................................ ✔ ✔ — — —• Heavy Vinyl - coated coil guard ................................................................................................... — — — ✔ —• Horizontal convertible to downflow .............................................................................................. ✔ ✔ ✔ ✔ ✔• Lite Port/Stored diagnostics ......................................................................................................... ✔ ✔ ✔ ✔ ✔• L.P. convertible ............................................................................................................................. ✔ ✔ ✔ ✔ ✔• Meets California NOX (as shipped) ............................................................................................. ✔ ✔ ✔ ✔ ✔• Multi-port in-shot burner .............................................................................................................. ✔ ✔ ✔ ✔ ✔• Plate Fin coils .............................................................................................................................. ✔ ✔ ✔ ✔ ✔• Two-stage cooling ........................................................................................................................ ✔ — — — —• Two-stage gas valve .................................................................................................................... ✔ ✔ — — —• 5-year limited compressor only warranty (Commercial use) ........................................................ ✔ ✔ ✔ ✔ ✔• 5-year limited compressor and outdoor coil warranty (Residential use) ...................................... — — — ✔ ✔• 5-year limited heat exchanger warranty (Commercial use) ......................................................... ✔ ✔ ✔ ✔ ✔• 5-year limited parts warranty (Residential use) ........................................................................... ✔ ✔ ✔ ✔ ✔• 1-year limited parts warranty (Commercial use) .......................................................................... ✔ ✔ ✔ ✔ ✔• 10-year limited compressor and outdoor coil warranty (Residential use) .................................... ✔ ✔ ✔ — —• 10-year limited heat exchanger warranty (Residential use) ......................................................... — — — ✔ ✔• 20-year limited heat exchanger warranty (Residential use) ......................................................... ✔ ✔ ✔ — —

Table PG-17-B — Comfort ControlsAY28X092 ............. Heat/Cool (Horizontal) ...................................................................................... ✔ ✔ ✔BAY28X1821 ....... 1-Stage Htg/Clg ................................................................................................ ✔ ✔ ✔BAY28X1831 ...... 2-Stage Htg/Clg ................................................................................................ ✔ ✔ ✔BAY28X184 ........... Subbase Auto/Manual Changeover .................................................................. ✔ ✔ ✔BAY28X187 ........... Subbase Auto Changeover ............................................................................... ✔ ✔ ✔BAY28X190 ........... Locking Thermostat Cover for Room Thermostat .............................................. ✔ ✔ ✔BAYBASE006A ...... Used w/BAYSTAT040B, 2 Htg / 2 Clg w/Economizer ........................................ ✔ ✔ ✔BAYBASE008A ...... Used w/BAYSTAT040B, 1 Htg / 1 Clg ............................................................... ✔ ✔ ✔BAYCOVR100A ..... Wall Cover Plate ............................................................................................... ✔ ✔ ✔BAYSTAT008 ......... Manual 1-Stage Htg/Clg ................................................................................... ✔ ✔ ✔BAYSTAT010 ......... Auto 2-Stage Heating/Cooling .......................................................................... ✔ ✔ ✔BAYSTAT012 ......... Manual 1-Stage Htg/2-Stage Clg w/Economizer ............................................... ✔ ✔ ✔BAYSTAT040B ....... Programmable (used with BAYBASE) ............................................................... ✔ ✔ ✔BAYSTAT253A ....... Humidity Control ............................................................................................... — — —BAYSTAT305 ......... Heat/Cool (Vertical) .......................................................................................... ✔ ✔ ✔TAYSENS100A2 ... Outdoor Temp. Sensor (with case) .................................................................... ✔ ✔ ✔TAYSTAT241 .......... Manual 2-Stage Htg/1-Stage Clg ...................................................................... ✔ ✔ ✔TAYSTAT300C ....... 7 day Programmable 1 Htg/1 Clg ...................................................................... ✔ ✔ ✔TAYSTAT302C ....... 7 day Programmable 2 Htg/2 Clg w/Economizer ............................................... ✔ ✔ ✔TAYSTAT340 .......... Prog., 5/2 Day, Manual, 1Htg/1 Clg ................................................................... ✔ ✔ ✔TAYSTAT350 .......... Prog., 5/2 Day, Manual, 2 (Gas)Htg/1 Clg ......................................................... ✔ ✔ ✔TAYSTAT370 .......... Electronic, Auto 1 Htg (Gas)/ 1Clg (Non Prog) .................................................. ✔ ✔ ✔TAYSTAT375 .......... Electronic, 2 Htg/ 2Clg (Non Prog) .................................................................... ✔ ✔ ✔TAYSTAT380 .......... Electronic, 2 Htg (Gas)/ 1Clg (Non Prog) .......................................................... — — —TCONT200A .......... 1Htg /1Clg (Gas, Oil or Electric) ........................................................................ ✔ ✔ ✔TCONT401A .......... 2Htg /1Clg (Heat Pump/A/C) ............................................................................ ✔ ✔ ✔TCONT402A .......... 3Htg /2Clg (Heat Pump/A/C) ............................................................................ ✔ ✔ ✔TCONT600A .......... 1Htg /1Clg (Heat Pump/A/C) ............................................................................ ✔ ✔ ✔TCONT602A .......... 2Htg /2Clg (Heat Pump/A/C) ............................................................................ ✔ ✔ ✔TCONT800A .......... 1Htg /1Clg (Gas, Oil or Electric) ........................................................................ ✔ ✔ ✔TCONT802A .......... 3Htg /2Clg (Heat Pump/A/C) ............................................................................ ✔ ✔ ✔

TCONT803A .......... 3Htg /2Clg (Heat Pump/A/C) w/Humidity Control .............................................. ✔ ✔ ✔

1 Requires Subbase.2 Used with TAYSTAT300C and TAYSTAT302C only.* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.

See

Com

fort

Con

trol

s/ Z

one

Sen

sors

Sec

tion

See

Com

fort

Con

trol

s/ Z

one

Sen

sors

Sec

tion

For information on Roof Curbs and Roof Curb Adaptors,please refer to the Accessories/Information Tab.

Page 218: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PG-18Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

PH

AS

ED

OU

T

YCZ-F YCY-G YCX-G YCP-F YCC-FTable PG-18-A — Accessories 3-5 2-5 2-5 2-5 11/2-5BAYASCT00178 .... Anti-Short Cycle Timer ..................................................................................... 3-5 2-5 2-5 2-5 1½-5BAYCCHT003A ...... Crankcase Heater (230v)1 ............................................................................. — 2-3½ 2 2 1½-5BAYCCHT202A ...... Crankcase Heater (230v) ................................................................................. — 2½-5 2½-5 2½-5 —BAYCCHT400A ...... Crankcase Heater (460v) ................................................................................. — — 2½-5 2½-5 —BAYCURB030A ...... Roof Curb (Flat Roof)3 (14 H x 34 W x 531/8 L) ............................................... 3-5 3-5 2-5 2-5 1½-5BAYCURB033A ...... Roof Curb (Flat Roof)3Acousti-Curb (14 H x 34 W x 605/8 L) .......................... 3 2-3½ 3½ M/H 36H-42M 3H,3½-4MBAYCURB034A ...... Roof Curb (Flat Roof)3 Acousti-Curb (14 H x 43 W x 621/16 L) .......................... 4-5 4-5 4-5 4-5 4H, 5MBAYCURB038A ...... Roof Curb (Flat Roof)3Acousti-Curb (14 H x 34 W x 531/8 L) .......................... 3-5 2-5 2-5 2-5 1½-5BAYDMPR040A ..... 0-25% Manual Fresh Air Damper (Downflow Only)2 ...................................... 3 2-3½ 2-3½ 2-3½ 1½-4MBAYDMPR041A ..... 0-25% Manual Fresh Air Damper (Downflow Only)2 ...................................... 4-5 4-5 4-5 4-5 4H-5MBAYDMPR050A ..... Motorized Fresh Air Damper ............................................................................ — — 4H-5M 4H-5M 4H-5MBAYDUCT004A ...... 12" Round Duct Adapters (2 per Box) Horizontal Only ..................................... 3 2-3½ 2-3½ 2-3½ 1½-4MBAYDUCT005A ...... 14" Round Duct Adapters (1 per Box) Horizontal Only ..................................... 4 2-3½ 2-3½ 2-3½ 1½-4MBAYECMT002A ...... Extreme Conditions Mouniting Kit (Curb Mount) .............................................. 3-5 2-5 2-5 2-5 1½-5BAYECMT003A ...... Extreme Conditions Mouniting Kit (Slab or Rack Mount) ................................. 3-5 2-5 2-5 2-5 1½-5BAYECON054B ...... 0-100% Mod. Economizer with Bar Relief – Downflow246 ............................ 3 2-3½ 2-3½ 2-3½ 1½-4MBAYECON055B ...... 0-100% Mod. Economizer with Bar Relief – Downflow246 ........................... 4-5 4-5 4-5 4-5 4H, 5MBAYECON073A ...... 0-100% Mod. Economizer – Horizontal246 .................................................. 3-5 2-5 2-5 2-5 1½-5BAYENTH001A ...... Enthalpy Control (Solid State)4 ...................................................................... 3-5 2-5 2-5 2-5 1½-5BAYFLTR012A ....... Filter Frame2 (20 x 25 x 1" filter not included) ................................................ — — 2-3½M 2-3½M 2½M-3LMBAYFLTR013A ....... Filter Frame2 (20 x 25 x 1" filter not included) ................................................ 3 2-3½LMH 3H-3½M 3H-3½M 3H,3½-4MBAYFLTR014A ....... Filter Frame2 (3-10 x 25 x 1" filter not included) ............................................. 4H-5M 4H-5M 4H-5M 4H-5M 4H-5MBAYFLTR015A ....... Filter Frame2 (20 x 20 x 1" filter not included) ................................................ — — 2L 2L 1½-2½LBAYFLTR017A ....... Filter Frame2 (20 x 25 x 2" filter not included) ................................................ — — 2-3½M 2-3½M 2½M-3LMBAYFLTR018A ....... Filter Frame2 (20 x 25 x 2" filter not included) ................................................ 3 2-3½LMH 3H-3½M 3H-3½M 3H-3½-4MBAYFLTR019A ....... Filter Frame2 (2-16 x 25 x 2" filter not included) ............................................. 4H-5M 4H-5M 4H-5M 4H-5M 4H-5MBAYGARD016A ...... Condenser Coil Guard ..................................................................................... — — — — 1½-2½LBAYGARD017A ...... Condenser Coil Guard ..................................................................................... — — — — 3½-4MBAYGARD018A ...... Condenser Coil Guard ..................................................................................... — — — — 2½M-3HBAYGARD021A ...... Condenser Coil Guard ..................................................................................... — — — — 4H-5MBAYHSMT043A ...... High Static Motor (230/460V) 3/4HP ................................................................ — — 2½-3½ 2½-3½ 2½-3½BAYHSMT044A ...... High Static Motor (230/460V) 1HP ................................................................... — — 4-5 4-5 4-5BAYHSMT045A ...... High Static Motor (208V) 1HP .......................................................................... — — 4-5 4-5 4-5BAYHSMT056A ...... High Static Motor (208V) 3/4HP ....................................................................... — — 2½-3½ 2½-3½ 2½-3½BAYINDK001A* ...... Insulated Deck Pan for A & B Cabinet .............................................................. — — 2-3LM 2-3LM 1½-3LMBAYINDK002A** ..... Insulated Deck Pan for C Cabinet .................................................................... 3M 2-3½LMH 3H-3½M 3H-3½M 3H,3½-4MBAYINDK003A*** ... Insulated Deck Pan for D Cabinet .................................................................... 4H-5M 4H-5M 4H-5M 4H-5M 4H-5MBAYKSKT010A ....... Quick Start Kit for (Single Phase Units) ........................................................... — — — — 1½-5BAYKSKT254 ......... Start Kit-Scroll Models Only (Single Phase Only) ............................................ — — 2½-4 2½-4 —BAYLIFT002B ......... Lifting Lug Kit .................................................................................................. 3-5 2-5 2-5 2-5 1½-5BAYLOAM011A ...... Evaporator Defrost Control Kit1 ....................................................................... 3-5 2-5 2-5 2-5 1½-5BAYLOAM323A ...... Head Pressure Control15 ............................................................................... — 2-5 2-5 2-5 1½-5BAYLOFR001B ...... Low Fire Kit ...................................................................................................... — — 1½-3L 1½-3L 1½-3LBAYLOFR002B ...... Low Fire Kit ...................................................................................................... — — 2M 2M 2MBAYLOFR003B ...... Low Fire Kit ...................................................................................................... — — 2½-3M 2½-3M 2½-3MBAYLOFR004B ...... Low Fire Kit ...................................................................................................... — — 3H,3½M 3H,3½M 3H,3½M-4MBAYLOFR005B ...... Low Fire Kit ...................................................................................................... — — — — —BAYLOFR006B ...... Low Fire Kit ...................................................................................................... — — 4-5 4-5 —BAYLOFR007B ...... Low Fire Kit ...................................................................................................... — — — — 4-5M, 4HBAYLPKT022A ....... LP Conversion Kit ............................................................................................ — — 2-5 2-5 1½-5BAYLPKT024C ....... LP Conversion Kit ............................................................................................ 3-5 2-5 — — —BAYLPSS001A ....... LP Conversion Kit with 5 Stainless steel burners ............................................. — — 2-5 2-5 1½-5

and 5 LP #54 orifices (Single Stage)BAYLPSS002A ....... LP Conversion Kit with 5 Stainless steel burners ............................................. 3-5 2-5 — — —

and 5 LP #54 orifices (Two Stage)BAYMOTR307A ...... 208-230V 1/2HP Ball Bearing OD Motor used with BAYLOAM323A .............................. — 2-5 2-5 2-5 1½-5BAYMOTR406A ...... 460V 1/2HP Ball Bearing OD Motor used with BAYLOAM323A ............................ — — 2-5 2-5 1½-5BAYOSAC001A ...... Outside Air Econo Controller ............................................................................ 3-5 — — — —BAYSTAT023 .......... Remote Potentiometer for BAYECON054B, 055B ............................................ 3-5 2-5 2-5 2-5 1½-5BAYUTIL030A ........ Roof Curb Utility Extension Kit for BAYCURB030, 038A .................................. — — — — 1½-5BAYUTIL033A ........ Roof Curb Utility Extension Kit for BAYCURB033A .......................................... — — — — 3H,3½-4MBAYUTIL034A ........ Roof Curb Utility Extension Kit for BAYCURB034A .......................................... — — — — 4H, 5M

Package Gas/ElectricConvertible 1½ through 5 Tons

1 Low ambient cooling requires crankcase heater.2 Must use filter frame when economizer/fresh air kit is used.3 Ships knocked down.4 Dry bulb control standard with economizer.5 May require motor change, see instruction guide.6 2-Stage thermostat provides additional energy savings if simultaneous economizer

and compressor operation is expected.

7 Activated on Power Off.8 Not for use with programmable thermostat.* Currently Shipped with BAYCURB038A.** Currently Shipped with BAYCURB033A.*** Currently Shipped with BAYCURB034A.L – Low heat modelM – Medium heat modelH – High heat model

For information on Roof Curbsand Roof Curb Adaptors, pleaserefer to the Accessories/Information Tab.

Page 219: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PG-19 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

PHASED OUT

C

BA

E

DD

F

ML

J

K ML

Y

N

X X

PHORIZONTALSUPPLYOPENING DOWNFLOW

SUPPLYOPENING

HORIZONTALRETURN OPENING

DOWNFLOWRETURN OPENING

CONDENSATE DRAIN19 MM (3/4") FEMALE NPT

48 MM (1 7/8") DIA. ENTRYFOR 13 MM (1/2) NPTGAS CONNECTION

EG

H

35 MM(1 3/8")

29 MM (1 1/8")

67 MM (2 5/8")

59 MM (2 5/16")

76 MM(3")

SUPPLY &RETURN PANEL

EVAPORATOR COIL &BLOWER PANEL

ECONOMIZER/FILTERACCESS PANEL

CENTER OFGRAVITY

Y

Table PG-19-A — YCZ – XL 1600 Dimensional DataModel A B C D E F G H J K L M N P BAYCURB0

YCZ036F-M 64 36 293/16 189/16 111/16 69/16 111/8 17 181/2 251/2 171/2 10 3 83/4 33AYCZ050F-H 651/8 45 333/8 211/16 151/16 415/16 91/8 2115/16 24 261/2 20 14 31/2 85/16 34AYCZ060F-M 651/8 45 333/8 211/16 151/16 415/16 91/8 2115/16 223/4 251/2 20 14 31/2 85/16 34A

Table PG-19-B — YCY – XL 1400 Dimensional DataModel A B C D E F G H J K L M N P BAYCURB0

YCY024G-L 64 36 293/16 189/16 111/16 69/16 111/8 17 205/16 291/2 171/2 10 3 83/4 30A, 38A, 33AYCY024G-M 64 36 293/16 189/16 111/16 69/16 111/8 17 211/2 291/2 171/2 10 3 83/4 30A, 38A, 33AYCY030G-L 64 36 293/16 189/16 111/16 69/16 111/8 17 195/16 281/2 171/2 10 3 83/4 30A, 38A, 33AYCY030G-M 64 36 293/16 189/16 111/16 69/16 111/8 17 195/16 281/2 171/2 10 3 83/4 30A, 38A, 33AYCY036G-M 64 36 293/16 189/16 111/16 69/16 111/8 17 191/2 287/32 171/2 10 3 83/4 30A, 38A, 33AYCY036G-H 64 36 293/16 189/16 111/16 69/16 111/8 17 1913/16 281/2 171/2 10 3 83/4 30A, 38A, 33AYCY042G-M 64 36 293/16 189/16 111/16 69/16 111/8 17 1913/16 281/2 171/2 10 3 83/4 30A, 38A, 33AYCY048G-H 651/8 45 333/8 211/16 151/16 415/16 91/8 2115/16 25 297/32 20 14 31/2 85/16 30A, 38A, 34AYCY060G-M 651/8 45 333/8 211/16 151/16 415/16 91/8 2115/16 25 297/32 20 14 31/2 85/16 30A, 38A, 34A

Table PG-19-C — YCX – XL 1200 Dimensional DataModel A B C D E F G H J K L M N P BAYCURB0

YCX024G-L 561/2 36 253/16 189/16 111/16 69/16 613/16 17 215/16 25 171/2 10 3 47/16 30A, 38AYCX030G-L 561/2 36 293/16 189/16 111/16 69/16 613/16 17 203/4 2513/16 171/2 10 3 47/16 30A, 38AYCX036G-L 561/2 36 293/16 189/16 111/16 69/16 613/16 17 193/4 2413/16 171/2 10 3 47/16 30A, 38AYCX024G-M 56 36 293/16 189/16 111/16 69/16 111/8 17 211/2 23 171/2 10 3 83/4 30A, 38AYCX030G-M 56 36 293/16 189/16 111/16 69/16 111/8 17 201/2 25 171/2 10 3 83/4 30A, 38AYCX036G-M 56 36 293/16 189/16 111/16 69/16 111/8 17 191/2 2715/16 171/2 10 3 83/4 30A, 38AYCX036G-H 64 36 293/16 189/16 111/16 69/16 111/8 17 193/4 281/4 171/2 10 3 83/4 30A, 38A, 33AYCX042G-M 64 36 293/16 189/16 111/16 69/16 111/8 17 193/4 281/4 171/2 10 3 83/4 30A, 38A, 33AYCX048G-H 645/16 45 333/8 211/16 151/16 415/16 91/8 2115/16 25 291/2 20 14 31/2 815/16 30A, 38A, 34AYCX060G-M 645/16 45 333/8 211/16 151/16 415/16 91/8 2115/16 25 291/2 20 14 31/2 815/16 30A, 38A, 34A

Package Gas/ElectricConvertible 2 through 5 Tons

For information on Roof Curbs and Roof Curb Adaptors,please refer to the Accessories/Information Tab.

Page 220: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PG-20Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

PHASED OUT

PHASED OUT

C

BA

E

DD

F

ML

J

K ML

Y

N

X X

PHORIZONTALSUPPLYOPENING DOWNFLOW

SUPPLYOPENING

HORIZONTALRETURN OPENING

DOWNFLOWRETURN OPENING

CONDENSATE DRAIN19 MM (3/4") FEMALE NPT

48 MM (1 7/8") DIA. ENTRYFOR 13 MM (1/2) NPTGAS CONNECTION

EG

H

35 MM(1 3/8")

29 MM (1 1/8")

67 MM (2 5/8")

59 MM (2 5/16")

76 MM(3")

SUPPLY &RETURN PANEL

EVAPORATOR COIL &BLOWER PANEL

ECONOMIZER/FILTERACCESS PANEL

CENTER OFGRAVITY

Y

Table PG-20-A — YCP – XE 1200 Dimensional DataModel A B C D E F G H J K L M N P BAYCURB0

YCP024F-L 56½ 36 253/16 189/16 111/16 69/16 613/16 17 21 21¼ 171/2 10 3 47/16 30A, 38AYCP024F-M 56½ 36 293/16 189/16 111/16 69/16 613/16 17 21 217/8 171/2 10 3 47/16 30A, 38AYCP030F-L 56½ 36 293/16 189/16 111/16 69/16 613/16 17 21 217/8 171/2 10 3 47/16 30A, 38AYCP030F-M 56½ 36 293/16 189/16 111/16 69/16 613/16 17 21 217/8 171/2 10 3 47/16 30A, 38AYCP036F-L 56½ 36 293/16 189/16 111/16 69/16 613/16 17 20½ 251/8 171/2 10 3 47/16 30A, 38AYCP036F-M 56½ 36 293/16 189/16 111/16 69/16 613/16 17 20½ 251/8 171/2 10 3 47/16 30A, 38AYCP036F-H 64 36 293/16 189/16 111/16 69/16 111/8 17 20½ 281/2 171/2 10 3 83/4 30A, 38A, 33AYCP042F-M 64 36 293/16 189/16 111/16 69/16 111/8 17 20½ 281/2 171/2 10 3 83/4 30A, 38A, 33AYCP048F-H 651/8 45 333/8 211/16 151/16 415/16 91/8 2115/16 253/8 30¼ 20 14 31/2 815/16 30A, 38A, 34AYCP060F-M 651/8 45 333/8 211/16 151/16 415/16 91/8 2115/16 253/8 287/8 20 14 31/2 815/16 30A, 38A, 34A

Table PG-20-B — YCC – XE 1000 Dimensional DataModel A B C D E F G H J K L M N P BAYCURB0

YCC018F-L 551/4 36 253/16 189/16 111/16 69/16 613/16 17 215/16 25 171/2 10 3 47/16 30A, 38AYCC024F-L 551/4 36 253/16 189/16 111/16 69/16 613/16 17 215/16 25 171/2 10 3 47/16 30A, 38AYCC030F-L 551/4 36 253/16 189/16 111/16 69/16 613/16 17 215/16 25 171/2 10 3 47/16 30A, 38AYCC036F-L 551/4 36 293/16 189/16 111/16 69/16 613/16 17 203/4 2513/16 171/2 10 3 47/16 30A, 38AYCC030F-M 551/4 36 293/16 189/16 111/16 69/16 613/16 17 193/4 2413/16 171/2 10 3 47/16 30A, 38AYCC036F-M 551/4 36 293/16 189/16 111/16 69/16 613/16 17 193/4 2413/16 171/2 10 3 47/16 30A, 38AYCC036F-H 623/4 36 293/16 189/16 111/16 69/16 111/8 17 193/4 281/4 171/2 10 3 83/4 30A, 38A, 33AYCC042F-M 623/4 36 293/16 189/16 111/16 69/16 111/8 17 193/4 281/4 171/2 10 3 83/4 30A, 38A, 33AYCC048F-M 623/4 36 293/16 189/16 111/16 69/16 111/8 17 193/4 281/4 171/2 10 3 83/4 30A, 38A, 33AYCC048F-H 645/16 45 333/8 211/16 151/16 415/16 91/8 2115/16 25 291/2 20 14 31/2 815/16 30A, 38A, 34AYCC060F-M 645/16 45 333/8 211/16 151/16 415/16 91/8 2115/16 25 291/2 20 14 31/2 815/16 30A, 38A, 34A

Package Gas/ElectricConvertible 1½ through 5 Tons

For information on Roof Curbs and Roof Curb Adaptors,please refer to the Accessories/Information Tab.

Page 221: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PG-21 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Standard Features:• Trane built scroll compressors on all 3-10 ton units except 3 ton standard efficiency

model (Reciprocating Compressor)• Colored and numbered wiring• Provisions for through the Base Gas and Condensate Drain Connections• Patented Hybrid Condenser Coil for easy cleaning• 1" throwaway filters provided on 3-5 ton units• 2" throwaway filters provided on 6-10 ton units• Liquid Line Refrigerant Drier• Operating Charge of R-22• IAQ Sloped Drain Pans• Low Ambient to 40°F on Electromechanical models• Low Ambient to 0°F on Microprocessor models• 5 - year Limited Compressor Warranty• 5 - year Limited Heat Exchanger Warranty• 1 - year Limited Parts Warranty

Added Flexibility

• Electromechanical or microprocessor controls (See page PC-35 for ReliaTel™Control Information)

• Standard or high efficiency cooling models available• Low, medium or high heat, single or two stage• Convertible airflow• Fork lift openings on three sides of unit• Direct or belt drive - standard or oversized motors (Direct for 3-5 ton only)• We don’t prepackage options• Choose options tailored to suit each job —pay only for what is needed• Units ship with options installed —and within our standard ship cycle time

Factory Installed Options

• Through-the-Base — Electrical• Convenience Outlet — Powered or unpowered• Unit Disconnect Switch• Smoke Detectors — Supply, return, or both• Condenser Coil Coating• Hinged Access Service Panels• Discharge Air Sensor• Fan Fail and Clogged Filter Switches• Condenser Coil Guard — Hail Protection Quality• Hot Gas Reheat Coil - Dehumidification• TXV thermal expansion valve and split face evaporator coil• TCI (Trane Communication Interface)• LonTalk (Communication Interface)• 2" Pleated Media filters• Phase Monitor• Frostat

The same Trane Quality andReliability … with added Flexibility!

Precedent™ 3-10 tonPackaged Gas Electrics

FeaturingA New Look for a New Century

Beveled TopSmoother DesignSmall compact cabinetRecessed access handles

Page 222: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PG-22Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Precedent™ Packaged Gas/ElectricConvertible 3-10 Tons

* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.1 Downflow Airflow/Horizontal Airflow2 HCAR Breaker per NEC.3 SEER applies, 3-5 tons; EER applies 6-10 tons.4 Digit 7 - A=R-22, E=410A.

Table PG-22-A — Base Unit — Standard Efficiency — ElectromechanicalHeating Output11111 Cabinet Shipping

Unit Performance33333 Cooling Capacity Dimensions (in.) Downflow Downflow Weight Max.2Tons Ordering No.44444 SEER/EER Capacity (Btuh) (Btuh) AFUE% H x W x L Supply Return (Ibs.) MCA* Fuse*

YSC – 208-230/1/60 – Single Phase – Low Heat3 YSC036E1ELA0000 13.0 35,620 47,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 27.2 404 YSC048E1ELA0000 13.0 49,210 49,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 35.2 505 YSC060E1ELA0000 13.0 59,900 47,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 43.8 70YSC –208-230/3/60 – Three Phase – Low Heat3 YSC036A3ELA0000 10.7 37,400 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 572 17.9 254 YSC048A3ELA0000 10.0 49,200 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 597 23.9 355 YSC060A3ELA0000 10.2 63,100 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 614 31.5 503 YSC036E3ELA0000 13.0 37,150 48,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 21.4 304 YSC048E3ELA0000 13.0 49,450 48,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 25.2 355 YSC060E3ELA0000 13.0 62,270 48,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 29.5 456 YSC072A3ELA0000 10.2/10.11 72,000 64,800 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 878 32.7 507½ YSC090A3ELA0000 10.1 90,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 963 42.7 607½ YSC092A3ELA0000 10.4/10.11 90,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 38.9 508½ YSC102A3ELA0000 10.1 105,000 97, 200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 45.1 6010 YSC120A3ELA0000 10.2/10.11 117,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1130 52.6 60YSC –460/3/60 – Three Phase – Low Heat3 YSC036A4ELA0000 10.7 37,400 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 572 9.2 154 YSC048A4ELA0000 10.0 49,200 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 597 12.8 205 YSC060A4ELA0000 10.2 63,100 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 614 16.0 253 YSC036E4ELA0000 13.0 37,150 48,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 10.1 154 YSC048E4ELA0000 13.0 49,450 48,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 12.5 155 YSC060E4ELA0000 13.0 62,270 48,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 15.5 256 YSC072A4ELA0000 10.2/10.11 72,000 64,800 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 878 17.6 257½ YSC090A4ELA0000 10.1 90,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 963 22.6 357½ YSC092A4ELA0000 10.4/10.11 90,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 20.5 258½ YSC102A4ELA0000 10.1 105,000 97,200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 24.0 3010 YSC120A4ELA0000 10.2/10.11 117,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1130 26.9 35YSC –575/3/60 – Three Phase – Low Heat3 YSC036AWELA0000 10.7 37,400 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 572 7.7 154 YSC048AWELA0000 10.0 49,200 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 597 9.8 155 YSC060AWELA0000 10.2 63,100 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 614 12.2 153 YSC036EWELA0000 13.0 37,150 48,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 8.0 154 YSC048EWELA0000 13.0 49,450 48,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 9.0 155 YSC060EWELA0000 13.0 62,270 48,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 10.1 156 YSC072AWELA0000 10.2/10.11 72,000 64,800 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 878 12.8 207½ YSC090AWELA0000 10.1 90,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 963 17.6 257½ YSC092AWELA0000 10.4/10.11 90,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 15.5 208½ YSC102AWELA0000 10.1 105,000 97,200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 19.5 2510 YSC120AWELA0000 10.2/10.11 117,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1130 21.8 257½ YSC092A3EMA0000 10.4/10.11 90,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 38.9 508½ YSC102A3EMA0000 10.1 105,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 44.4 6010 YSC120A3EMA0000 10.2/10.11 117,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1130 50.9 60

Page 223: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PG-23 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Precedent™ Packaged Gas/ElectricConvertible 3-10 Tons

* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.1 Downflow Airflow/Horizontal Airflow2 HCAR Breaker per NEC.3 SEER applies, 3-5 tons; EER applies 6-10 tons.4 Digit 7 - A=R-22, E=410A.

Table PG-23-A — Base Unit — Standard Efficiency — ElectromechanicalHeating Output11111 Cabinet Shipping

Unit Performance33333 Cooling Capacity Dimensions (in.) Downflow Downflow Weight Max.2Tons Ordering No.44444 SEER/EER Capacity (Btuh) (Btuh) AFUE% H x W x L Supply Return (Ibs.) MCA* Fuse*

YSC – 208-230/1/60 – Single Phase – Medium Heat3 YSC036E1EMA0000 13.0 35,620 65,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 27.2 404 YSC048E1EMA0000 13.0 49,210 65,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 35.2 505 YSC060E1EMA0000 13.0 59,900 64,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 43.8 70

YSC –208-230/3/60 – Three Phase – Medium Heat3 YSC036A3EMA0000 10.7 37,400 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 572 17.9 254 YSC048A3EMA0000 10.0 49,200 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 597 23.9 355 YSC060A3EMA0000 10.2 63,100 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 614 31.5 503 YSC036E3EMA0000 13.0 37,150 64,000 81 32 x 44 x 70 18 x 15.5 12 x 14 607 21.4 304 YSC048E3EMA0000 13.0 49,450 64,000 81 32 x 44 x 70 18 x 15.5 12 x 14 638 25.2 355 YSC060E3EMA0000 13.0 62,270 64,000 81 32 x 44 x 70 18 x 15.5 12 x 14 688 29.5 456 YSC072A3EMA0000 10.2/10.11 72,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 878 32.2 507½ YSC090A3EMA0000 10.1 90,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 963 42.7 607½ YSC092A3EMA0000 10.4/10.11 90,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 38.9 508½ YSC102A3EMA0000 10.1 105,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 44.4 6010 YSC120A3EMA0000 10.2/10.11 117,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1130 50.9 60

YSC –460/3/60 – Three Phase – Medium Heat3 YSC036A4EMA0000 10.7 37,400 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 572 9.2 154 YSC048A4EMA0000 10.0 49,200 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 597 12.8 205 YSC060A4EMA0000 10.2 63,100 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 614 16.0 253 YSC036E4EMA0000 13.0 37,150 64,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 10.1 154 YSC048E4EMA0000 13.0 49,450 64,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 12.5 155 YSC060E4EMA0000 13.0 62,270 64,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 15.5 256 YSC072A4EMA0000 10.2/10.11 63,100 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 878 17.6 257½ YSC090A4EMA0000 10.1 90,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 963 22.6 357½ YSC092A4EMA0000 10.4/10.11 90,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 20.5 258½ YSC102A4EMA0000 10.11 105,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 24.0 3010 YSC120A4EMA0000 10.2/10.11 117,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1130 26.9 35

YSC –575/3/60 – Three Phase – Medium Heat3 YSC036AWEMA0000 10.7 37,400 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 572 7.7 154 YSC048AWEMA0000 10.0 49,200 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 597 9.8 155 YSC060AWEMA0000 10.2 63,100 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 614 12.2 153 YSC036EWEMA0000 13.0 37,150 64,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 8.0 154 YSC048EWEMA0000 13.0 49,450 64,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 9.0 155 YSC060EWEMA0000 13.0 62,270 64,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 10.1 156 YSC072AWEMA0000 10.2/10.11 63,100 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 878 12.8 207½ YSC090AWEMA0000 10.1 90,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 963 17.6 257½ YSC092AWEMA0000 10.4/10.11 90,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 15.5 208½ YSC102AWEMA0000 10.1 105,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 19.5 2510 YSC120AWEMA0000 10.2/10.11 117,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1130 21.8 25

Page 224: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PG-24Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Precedent™ Packaged Gas/ElectricConvertible 3-10 Tons

* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.1 Downflow Airflow/Horizontal Airflow2 HCAR Breaker per NEC.3 SEER applies, 3-5 tons; EER applies 6-10 tons.4 Digit 7 - A=R-22, E=410A.

Table PG-24-A — Base Unit — Standard Efficiency — ElectromechanicalHeating Output11111 Cabinet Shipping

Unit Performance33333 Cooling Capacity Dimensions (in.) Downflow Downflow Weight Max.2Tons Ordering No.44444 SEER/EER Capacity (Btuh) (Btuh) AFUE% H x W x L Supply Return (Ibs.) MCA* Fuse*

YSC –208-230/1/60 – Single Phase – High Heat3 YSC036E1EHA0000 13.0 35,620 94,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 27.2 404 YSC048E1EHA0000 13.0 49,210 95,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 35.2 505 YSC060E1EHA0000 13.0 59,900 103,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 43.8 70

YSC –208-230/3/60 – Three Phase – High Heat3 YSC036A3EHA0000 10.7 37,400 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 572 17.9 254 YSC048A3EHA0000 10.0 49,200 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 597 23.9 355 YSC060A3EHA0000 10.2 63,100 104,000 81 36 x 44 x 70 18 x 15.5 24 x 14 614 31.5 503 YSC036E3EHA0000 13.0 37,150 96,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 21.4 304 YSC048E3EHA0000 13.0 49,450 96,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 25.2 355 YSC060E3EHA0000 13.0 62,270 104,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 29.5 456 YSC072A3EHA0000 10.1 72,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 878 32.7 507½ YSC090A3EHA0000 10.1 90,000 162,000 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 963 42.7 607½ YSC092A3EHA0000 10.4/10.11 90,000 162,000 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 38.9 508½ YSC102A3EHA0000 10.11 105,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 45.1 6010 YSC120A3EHA0000 10.2/10.11 117,000 202,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1130 52.6 60

YSC –460/3/60 – Three Phase – High Heat3 YSC036A4EHA0000 10.7 37,400 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 572 9.2 154 YSC048A4EHA0000 10.0 49,200 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 597 12.8 205 YSC060A4EHA0000 10.2 63,100 104,000 81 36 x 44 x 70 18 x 15.5 24 x 14 614 16.0 253 YSC036E4EHA0000 13.0 37,150 96,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 10.1 154 YSC048E4EHA0000 13.0 49,450 96,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 12.5 155 YSC060E4EHA0000 13.0 62,270 104,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 15.5 256 YSC072A4EHA0000 10.1 72,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 878 17.6 257½ YSC090A4EHA0000 10.1 90,000 162,000 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 963 22.6 357½ YSC092A4EHA0000 10.4/10.11 90,000 162,000 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 20.5 258½ YSC102A4EHA0000 10.1 105,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 24.0 3010 YSC120A4EHA0000 10.2/10.11 117,000 202,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1130 26.9 35

YSC –575/3/60 – Three Phase – High Heat3 YSC036AWEHA0000 10.7 37,400 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 572 7.7 154 YSC048AWEHA0000 10.0 49,200 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 597 9.8 155 YSC060AWEHA0000 10.2 63,100 104,000 81 36 x 44 x 70 18 x 15.5 24 x 14 614 12.2 153 YSC036EWEHA0000 13.0 37,150 96,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 8.0 154 YSC048EWEHA0000 13.0 49,450 96,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 9.0 155 YSC060EWEHA0000 13.0 2,270 104,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 10.1 156 YSC072AWEHA0000 10.2/10.11 72,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 878 12.8 207½ YSC090AWEHA0000 10.1 90,000 162,000 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 963 17.6 257½ YSC092AWEHA0000 10.4/10.11 90,000 162,000 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 15.5 208½ YSC102AWEHA0000 /10.1 105,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 19.5 2510 YSC120AWEHA0000 10.2/10.11 117,000 202,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1130 21.8 25

Page 225: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PG-25 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Precedent™ Packaged Gas/ElectricConvertible 3-10 Tons

Table PG-25-A — Base Unit — Standard Efficiency — ReliaTel™ Microprocessor ControlsHeating Output11111 Cabinet Shipping

Unit Performance33333 Cooling Capacity Dimensions (in.) Downflow Downflow Weight Max.2Tons Ordering No.44444 SEER/EER Capacity (Btuh) (Btuh) AFUE% H x W x L Supply Return (Ibs.) MCA* Fuse*

YSC – 208-230/1/60 – Single Phase – Low Heat3 YSC036E1RLA0000 13.0 35,620 47,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 27.2 404 YSC048E1RLA0000 13.0 49,210 47,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 35.2 505 YSC060E1RLA0000 13.0 59,900 47,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 43.8 70

YSC –208-230/3/60 – Three Phase – Low Heat3 YSC036A3RLA0000 10.7 37,400 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 572 17.9 254 YSC048A3RLA0000 10.0 49,200 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 597 23.9 355 YSC060A3RLA0000 10.2 63,100 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 614 31.5 503 YSC036E3RLA0000 13.0 37,150 48,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 21.4 304 YSC048E3RLA0000 13.0 49,450 48,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 25.2 355 YSC060E3RLA0000 13.0 62,270 48,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 29.5 456 YSC072A3RLA0000 10.2/10.11 72,000 64,800 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 878 32.7 507½ YSC090A3RLA0000 10.1 90,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 963 42.7 607½ YSC092A3RLA0000 10.4/10.11 90,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 38.9 508½ YSC102A3RLA0000 10.1 105,000 97, 200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 45.1 6010 YSC120A3RLA0000 10.2/10.11 117,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1130 52.6 60

YSC –460/3/60 – Three Phase – Low Heat3 YSC036A4RLA0000 10.7 37,400 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 572 9.2 154 YSC048A4RLA0000 10.0 49,200 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 597 12.8 205 YSC060A4RLA0000 10.2 63,100 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 614 16.0 253 YSC036E4RLA0000 13.0 37,150 48,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 10.1 154 YSC048E4RLA0000 13.0 49,450 48,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 12.5 155 YSC060E4RLA0000 13.0 62,270 48,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 15.5 256 YSC072A4RLA0000 10.2/10.11 72,000 64,800 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 878 17.6 257½ YSC090A4RLA0000 10.1 90,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 963 22.6 357½ YSC092A4RLA0000 10.4/10.11 90,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 20.5 258½ YSC102A4RLA0000 10.1 105,000 97,200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 24.0 3010 YSC120A4RLA0000 10.2/10.11 117,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1130 26.9 35

YSC –575/3/60 – Three Phase – Low Heat3 YSC036AWRLA0000 10.7 37,400 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 572 7.7 154 YSC048AWRLA0000 10.0 49,200 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 597 9.8 155 YSC060AWRLA0000 10.2 63,100 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 614 12.2 153 YSC036EWRLA0000 13.0 37,150 48,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 8.0 154 YSC048EWRLA0000 13.0 49,450 48,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 9.0 155 YSC060EWRLA0000 13.0 62,270 48,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 10.1 156 YSC072AWRLA0000 10.2/10.11 72,000 64,800 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 878 12.8 207½ YSC090AWRLA0000 10.1 90,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 963 17.6 257½ YSC092AWRLA0000 10.4/10.11 90,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 15.5 208½ YSC102AWRLA0000 10.1 105,000 97,200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 19.5 2510 YSC120AWRLA0000 10.2/10.11 117,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1130 21.8 25

* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.1 Downflow Airflow/Horizontal Airflow2 HCAR Breaker per NEC.3 SEER applies, 3-5 tons; EER applies 6-10 tons.4 Digit 7 - A=R-22, E=410A..

Page 226: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PG-26Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Precedent™ Packaged Gas/ElectricConvertible 3-10 Tons

Table PG-26-A — Base Unit — Standard Efficiency — ReliaTel™ Microprocessor ControlsHeating Output11111 Cabinet Shipping

Unit Performance33333 Cooling Capacity Dimensions (in.) Downflow Downflow Weight Max.2Tons Ordering No.44444 SEER/EER Capacity (Btuh) (Btuh) AFUE% H x W x L Supply Return (Ibs.) MCA* Fuse*

YSC – 208-230/1/60 – Single Phase – Medium Heat3 YSC036E1RMA0000 13.0 35,620 65,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 27.2 404 YSC048E1RMA0000 13.0 49,210 65,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 35.2 505 YSC060E1RMA0000 13.0 59,900 64,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 43.8 70

YSC –208-230/3/60 – Three Phase – Medium Heat3 YSC036A3RMA0000 10.7 37,400 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 572 17.9 254 YSC048A3RMA0000 10.0 49,200 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 597 23.9 355 YSC060A3RMA0000 10.2 63,100 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 614 31.5 503 YSC036E3RMA0000 13.0 37,150 64,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 21.4 304 YSC048E3RMA0000 13.0 49,450 64,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 25.2 355 YSC060e3RMA0000 13.0 62,270 64,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 29.5 456 YSC072A3RMA0000 10.2/10.11 72,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 878 32.7 507½ YSC090A3RMA0000 10.1 90,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 963 42.7 607½ YSC092A3RMA0000 10.4/10.11 90,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 38.9 508½ YSC102A3RMA0000 10.1 105,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 45.1 6010 YSC120A3RMA0000 10.2/10.11 117,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1130 52.6 60

YSC –460/3/60 – Three Phase – Medium Heat3 YSC036A4RMA0000 10.7 37,400 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 572 9.2 154 YSC048A4RMA0000 10.0 49,200 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 597 12.8 205 YSC060A4RMA0000 10.2 63,100 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 614 16.0 253 YSC036E4RMA0000 13.0 37,150 64,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 10.1 154 YSC048E4RMA0000 13.0 49,450 64,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 12.5 155 YSC060E4RMA0000 13.0 62,270 64,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 15.5 256 YSC072A4RMA0000 10.2/10.11 63,100 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 878 17.6 257½ YSC090A4RMA0000 10.1 90,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 963 22.6 357½ YSC092A4RMA0000 10.4/10.11 90,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 20.5 258½ YSC102A4RMA0000 10.1 105,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 24.0 3010 YSC120A4RMA0000 10.2/10.11 117,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1130 26.9 35

YSC –575/3/60 – Three Phase – Medium Heat3 YSC036AWRMA0000 10.7 37,400 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 572 7.7 154 YSC048AWRMA0000 10.0 49,200 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 597 9.8 155 YSC060AWRMA0000 10.2 63,100 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 614 12.2 153 YSC036EWRMA0000 13.0 37,150 64,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 8.0 154 YSC048EWRMA0000 13.0 49,450 64,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 9.0 155 YSC060EWRMA0000 13.0 62,270 64,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 10.1 156 YSC072AWRMA0000 10.1 63,100 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 878 12.8 207½ YSC090AWRMA0000 10.1 90,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 963 17.6 257½ YSC092AWRMA0000 10.4/10.11 90,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 15.5 208½ YSC102AWRMA0000 10.2 105,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 19.5 2510 YSC120AWRMA0000 10.2/10.11 117,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1130 21.8 25

* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.1 Downflow Airflow/Horizontal Airflow2 HCAR Breaker per NEC.3 SEER applies, 3-5 tons; EER applies 6-10 tons.4 Digit 7 - A=R-22, E=410A.

Page 227: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PG-27 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Precedent™ Packaged Gas/ElectricConvertible 3-10 Tons

Table PG-27-A — Base Unit — Standard Efficiency — ReliaTel™ Microprocessor ControlsHeating Output11111 Cabinet Shipping

Unit Performance33333 Cooling Capacity Dimensions (in.) Downflow Downflow Weight Max.2Tons Ordering No.44444 SEER/EER Capacity (Btuh) (Btuh) AFUE% H x W x L Supply Return (Ibs.) MCA* Fuse*

YSC –208-230/1/60 – Single Phase – High Heat3 YSC036E1RHA0000 13.0 35,620 94,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 27.2 404 YSC048E1RHA0000 13.0 49,210 95,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 35.2 505 YSC060E1RHA0000 13.0 59,900 103,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 43.8 70

YSC –208-230/3/60 – Three Phase – High Heat3 YSC036A3RHA0000 10.7 37,400 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 572 17.9 254 YSC048A3RHA0000 10.0 49,200 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 597 23.9 355 YSC060A3RHA0000 10.2 63,100 104,000 81 36 x 44 x 70 18 x 15.5 24 x 14 614 31.5 503 YSC036E3RHA0000 13.0 37,150 96,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 21.4 304 YSC048E3RHA0000 13.0 49,450 96,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 25.2 355 YSC060E3RHA0000 13.0 62,270 104,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 29.5 456 YSC072A3RHA0000 10.2/10.11 72,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 878 32.7 507½ YSC090A3RHA0000 10.1 90,000 162,000 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 963 42.7 607½ YSC092A3RHA0000 10.4/10.11 90,000 162,000 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 38.9 508½ YSC102A3RHA0000 10.1 105,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 45.1 6010 YSC120A3RHA0000 10.2/10.11 117,000 202,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1130 52.6 60

YSC –460/3/60 – Three Phase – High Heat3 YSC036A4RHA0000 10.7 37,400 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 572 9.2 154 YSC048A4RHA0000 10.0 49,200 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 597 12.8 205 YSC060A4RHA0000 10.2 63,100 104,000 81 36 x 44 x 70 18 x 15.5 24 x 14 614 16.0 253 YSC036E4RHA0000 13.0 37,150 96,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 10.1 154 YSC048E4RHA0000 13.0 49,450 96,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 12.5 155 YSC060E4RHA0000 13.0 62,270 104,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 15.5 256 YSC072A4RHA0000 10.2/10.11 72,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 878 17.6 257½ YSC090A4RHA0000 10.1 90,000 162,000 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 963 22.6 357½ YSC092A4RHA0000 10.4/10.11 90,000 162,000 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 20.5 258½ YSC102A4RHA0000 10.1 105,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 24.0 3010 YSC120A4RHA0000 10.2/10.11 117,000 202,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1130 26.9 35

YSC –575/3/60 – Three Phase – High Heat3 YSC036AWRHA0000 10.7 37,400 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 572 7.7 154 YSC048AWRHA0000 10.0 49,200 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 597 9.8 155 YSC060AWRHA0000 10.2 63,100 104,000 81 36 x 44 x 70 18 x 15.5 24 x 14 614 12.2 153 YSC036EWRHA0000 13.0 37,150 96,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 8.0 154 YSC048EWRHA0000 13.0 49,450 96,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 9.0 155 YSC060EWRHA0000 13.0 62,270 104,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 10.1 156 YSC072AWRHA0000 10.2/10.11 72,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 878 12.8 207½ YSC090AWRHA0000 10.1 90,000 162,000 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 963 17.6 257½ YSC092AWRHA0000 10.4/10.11 90,000 162,000 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 15.5 208½ YSC102AWRHA0000 10.1 105,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 19.5 2510 YSC120AWRHA0000 10.2/10.11 117,000 202,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 11300 21.8 25

* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.1 Downflow Airflow/Horizontal Airflow2 HCAR Breaker per NEC.3 SEER applies, 3-5 tons; EER applies 6-10 tons.4 Digit 7 - A=R-22, E=410A.

Page 228: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PG-28Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Precedent™ Packaged Gas/ElectricConvertible 3-10 Tons

Table PG-28-A — Base Unit — High Efficiency — ElectromechanicalHeating Output11111 Cabinet Shipping

Unit Performance33333 Cooling Capacity Dimensions (in.) Downflow Downflow Weight Max.2Tons Ordering No. SEER/EER Capacity (Btuh) (Btuh) AFUE% H x W x L Supply Return (Ibs.) MCA* Fuse*

YHC –208-230/3/60 – Three Phase – Low Heat6 YHC072A3ELA0000 11.5/11.31 72,000 64,800 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 34.8 507½ YHC092A3ELA0000 11.5/11.31 90,000 97,200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1066 38.1 508½ YHC102A3ELA0000 11.5/11.31 102,000 97, 200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1100 42.3 5010 YHC120A3ELA0000 11.2/10.71 116,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1203 48.6 60

YHC –460/3/60 – Three Phase – Low Heat6 YHC072A4ELA0000 11.5/11.31 72,000 64,800 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 17.5 257½ YHC092A4ELA0000 11.5/11.31 90,000 97,200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1066 19.4 258½ YHC102A4ELA0000 11.5/11.31 102,000 97,200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1100 21.4 2510 YHC120A4ELA0000 11.2/10.71 116,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1203 25.3 30

YHC –575/3/60 – Three Phase – Low Heat6 YHC072AWELA0000 11.5/11.31 72,000 64,800 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 13.5 207½ YHC092AWELA0000 11.5/11.31 90,000 97,200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1066 14.8 158½ YHC102AWELA0000 11.5/11.31 102,000 97,200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1100 16.6 2010 YHC120AWELA0000 11.2/10.71 116,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1203 19.9 25

YHC –208-230/3/60 – Three Phase – Medium Heat6 YHC072A3EMA0000 11.5/11.31 72,000 97,200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 915 34.8 507½ YHC092A3EMA0000 11.5/11.31 90,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1066 38.1 508½ YHC102A3EMA0000 11.5/11.31 102,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1100 42.3 5010 YHC120A3EMA0000 11.2/10.71 116,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1203 48.6 60

YHC –460/3/60 – Three Phase – Medium Heat6 YHC072A4EMA0000 11.4/11.01 72,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 17.5 257½ YHC092A4EMA0000 11.4/11.01 90,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1066 19.4 258½ YHC102A4EMA0000 11.4/11.01 102,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1100 21.4 2510 YHC120A4EMA0000 11.3/10.81 116,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1203 25.3 30

YHC –575/3/60 – Three Phase – Medium Heat6 YHC072AWEMA0000 11.4/11.01 72,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 13.5 207½ YHC092AWEMA0000 11.4/11.01 90,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1066 14.8 158½ YHC102AWEMA0000 11.4/11.01 102,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1100 16.6 2010 YHC120AWEMA0000 11.3/10.81 116,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1203 19.9 25

YHC –208-230/3/60 – Three Phase – High Heat6 YHC072A3EHA0000 11.4/11.01 72,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 34.8 507½ YHC092A3EHA0000 11.4/11.01 90,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1066 38.1 508½ YHC102A3EHA0000 11.4/11.01 102,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1100 42.3 5010 YHC120A3EHA0000 11.3/10.81 116,000 202,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1203 48.6 60

YHC –460/3/60 – Three Phase – High Heat6 YHC072A4EHA0000 11.4/11.01 72,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 17.5 257½ YHC092A4EHA0000 11.4/11.01 90,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1066 19.4 258½ YHC102A4EHA0000 11.4/11.01 102,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1100 21.4 2510 YHC120A4EHA0000 11.3/10.81 116,000 202,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1203 25.3 30

YHC –575/3/60 – Three Phase – High Heat6 YHC072AWEHA0000 11.4/11.01 72,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 13.5 207½ YHC092AWEHA0000 11.4/11.01 90,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1066 14.8 158½ YHC102AWEHA0000 11.4/11.01 102,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1100 16.6 2010 YHC120AWEHA0000 11.3/10.81 116,000 202,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1203 19.9 25

* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.1 Downflow Airflow/Horizontal Airflow2 HCAR Breaker per NEC.3 SEER applies, 3-5 tons; EER applies 6-10 tons.

Page 229: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PG-29 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Precedent™ Packaged Gas/ElectricConvertible 3-10 Tons

Table PG-29-A — Base Unit — High Efficiency — ReliaTel™ Microprocessor ControlsHeating Output11111 Cabinet Shipping

Unit Performance33333 Cooling Capacity Dimensions (in.) Downflow Downflow Weight Max.2Tons Ordering No. SEER/EER Capacity (Btuh) (Btuh) AFUE% H x W x L Supply Return (Ibs.) MCA* Fuse*

YHC –208-230/3/60 – Three Phase – Low Heat6 YHC072A3RLA0000 11.4/11.01 72,000 64,800 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 34.8 507½ YHC092A3RLA0000 11.4/11.01 90,000 97,200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1066 38.1 508½ YHC102A3RLA0000 11.4/11.01 102,000 97, 200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1100 42.3 5010 YHC120A3RLA0000 11.3/10.81 116,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1203 48.6 60

YHC –460/3/60 – Three Phase – Low Heat6 YHC072A4RLA0000 11.4/11.01 72,000 64,800 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 17.5 257½ YHC092A4RLA0000 11.4/11.01 90,000 97,200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1066 19.4 258½ YHC102A4RLA0000 11.4/11.01 102,000 97,200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1100 21.4 2510 YHC120A4RLA0000 11.3/10.81 116,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1203 25.3 30

YHC –575/3/60 – Three Phase – Low Heat6 YHC072AWRLA0000 11.4/11.01 72,000 64,800 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 13.5 207½ YHC092AWRLA0000 11.4/11.01 90,000 97,200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1066 14.8 158½ YHC102AWRLA0000 11.4/11.01 105,000 97,200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1100 16.6 2010 YHC120AWRLA0000 11.3/10.81 116,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1203 19.9 25

YHC –208-230/3/60 – Three Phase – Medium Heat6 YHC072A3RMA0000 11.4/11.01 72,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 34.8 507½ YHC092A3RMA0000 11.4/11.01 90,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1066 38.1 508½ YHC102A3RMA0000 11.4/11.01 102,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1100 42.3 5010 YHC120A3RMA0000 11.3/10.81 116,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1203 48.6 60

YHC –460/3/60 – Three Phase – Medium Heat6 YHC072A4RMA0000 11.4/11.01 72,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 17.5 257½ YHC092A4RMA0000 11.4/11.01 90,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1066 19.4 258½ YHC102A4RMA0000 11.4/11.01 102,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1100 21.4 2510 YHC120A4RMA0000 11.3/10.81 116,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1203 25.3 30

YHC –575/3/60 – Three Phase – Medium Heat6 YHC072AWRMA0000 11.4/11.01 72,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 13.5 207½ YHC092AWRMA0000 11.4/11.01 90,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1066 14.8 158½ YHC102AWRMA0000 11.4/11.01 102,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1100 16.6 2010 YHC120AWRMA0000 11.3/10.81 116,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1203 19.9 25

YHC –208-230/3/60 – Three Phase – High Heat6 YHC072A3RHA0000 11.4/11.01 72,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 34.8 507½ YHC092A3RHA0000 11.4/11.01 90,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1066 38.1 508½ YHC102A3RHA0000 11.4/11.01 102,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1100 42.3 5010 YHC120A3RHA0000 11.3/10.81 116,000 202,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1203 48.6 60

YHC –460/3/60 – Three Phase – High Heat6 YHC072A4RHA0000 11.4/11.01 72,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 17.5 257½ YHC092A4RHA0000 11.4/11.01 90,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1066 19.4 258½ YHC102A4RHA0000 11.4/11.01 102,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1100 21.4 2510 YHC120A4RHA0000 11.3/10.81 116,000 202,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1203 25.3 30

YHC –575/3/60 – Three Phase – High Heat6 YHC072AWRHA0000 11.4/11.01 72,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 13.5 207½ YHC092AWRHA0000 11.4/11.01 90,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1066 14.8 158½ YHC102AWRHA0000 11.4/11.01 102,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1100 16.6 2010 YHC120AWRHA0000 11.3/10.81 116,000 202,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1203 19.9 25

* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.1 Downflow Airflow/Horizontal Airflow2 HCAR Breaker per NEC.3 SEER applies, 3-5 tons; EER applies 6-10 tons.

Page 230: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PG-30Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Precedent™ Packaged Gas/ElectricConvertible 3-10 Tons(Model Digit Numbers)

Digit Description Order Number1-8 Main Assembly (see previous page)9 Unit Controls

Electromechanical .................................................... EUnit Controls -ReliaTel™ Micro-processor .................. R

10 Heating CapacityLow ......................................................................... LMedium .................................................................. MHigh ......................................................................... HLow - Stainless Steel Heat Exchanger ....................... XMedium - Stainless Steel Heat Exchanger .................. YHigh - Stainless Steel Heat Exchanger ....................... Z

11 Minor Design Sequence First Sequence ........................................................ A

12-13 Service SequenceFirst Sequence (Factory assigned) .......................... ✱,✱

14 Fresh Air SelectionNo Fresh Air ............................................................. 00-50% Manual Outside Air Dampere ......................... A0-50% Motorized Outside Air Damper ........................ B0-100% Economizer, Dry Bulb without

Barometric Relief2 ................................................ C0-100% Economizer, Dry Bulb with

Barometric Relief2 ............................................... D0-100% Economizer, Reference Enthalpy

without Barometric Relief12 .................................. E0-100%Economizer, Reference Enthalpy

with Barometric Relief12 ....................................... F0-100%Economizer, Comparative Enthalpy

without Barometric Relief 12 ................................ G0-100%Economizer, Comparative Enthalpy

with Barometric Relief 12 ...................................... H15 Supply Fan/Drive Type/Motor

Standard Drive ......................................................... 0Oversized Motor ....................................................... 1Optional Belt Drive Motor (3 phase only) .................... 2

16 Hinged Service Access & FiltersStandard Panels & Filters ......................................... 0Hinged Access Panels & Standard Filters .................. AStandard panels & 2" Pleated Filters .......................... BHinged Access Panels & 2" Pleated Filters ................ C

17 Condenser Coil ProtectionStandard Coil ........................................................... 0Standard Coil with Hail Guard ................................... 1Epoxy Coated Condenser Coil .................................. 2Epoxy Coated Condenser Coil with Hail Guard .......... 3

18 Through the Base ProvisionsNo Through the Base Provisions ............................... 0Through the Base Electrict ...................................... AThrough the Base Gas .............................................. BThrough the Base Gas and Electricw ......................... C

19 Disconnect/Circuit Breaker/Phase Monitor (3 phase only)No Disconnect Circuit Breaker/No Phase Monitor ....... 0Non-Fused Disconnectt ........................................... 1Circuit Breakert ....................................................... 2Phase Monitory ....................................................... 3Phase Monitory & Non-Fused Disconnect Switch ...... 4Phase Monitory & Circuit Breaker ............................. 5

20 Convenience OutletNo Convenience Outlet ............................................. 0Unpowered Convenience Outlet ............................... APowered Convenience Outlet (3 phase only)3 ........... B

21 Communications Optionsu

No Communications Interface ................................... 0Trane Communications Interface ............................... 1LonTalk® Communications Interface .......................... 2Novar 2024 Controls ................................................. 3Novar 3051 Controls ................................................. 4

22 Refrigeration System OptionStandard Refrigeration System4 ............................... 0Thermal Expansion Value (TXV)4 ............................. ADehumidification (Hot Gas Reheat Coil)r .................. B

23 Refrigeration ControlsNo Refrigeration Control ........................................... 0High Pressure Control6u ......................................... 1Frostat5 .................................................................. 2Crankcase Heater .................................................... 3High Pressure Control6u and Frostat5 ..................... 4High Pressure Control6u and Crankcase Heater ....... 5Frostat5 and Crankcase Heater6 ............................. 6High Pressure Control6u, Frostat5 and

Crankcase Heater6 .............................................. 724 Smoke Detector7u

No Smoke Detector .................................................. 0Return Air Smoke Detector89 .................................. ASupply Air Smoke Detector ....................................... BSupply and Return Air Smoke Detectors89 ............... C

25 Monitoring Controlsu

No Monitoring Control0 ............................................ 0Clogged Filter Switch0 ............................................. 1Fan Failure Switch0 ................................................. 2Discharge Air Sensing Tube0 ................................... 3Clogged Filter Switch and Fan Fail Switch0 ............... 4Clogged Filter Switch and Discharge

Air Sensing Tube0 ................................................ 5Fan Fail Switch and Discharge Air Sensing Tube0 ..... 6Clogged Filter and Fan Fail Switches

and Discharge Air Sensing Tube0 .......................... 7Novar Return Air Sensorq ........................................ 8

1 Enthalpy control not available factory installed with electro-mechanical controls.2 Economizer with Barometric Relief is for downfllow configured units only. Order

Economizer without Barometric Relief for horizontal configuration. Barometric relief forhorizontal configured units must be ordered as field installed accessory BAYBARM010A.

3 Requires use of Disconnect or Circuit Breaker.4 Standard refrigeration metering device - short orifice.5 Frostat cannot be field installed in electro-mechanical units.6 High Pressure control is standard on 3 phase units with scroll compressors and in

YSC036A.7 Not available with BAYFRST001A High Temperature Stat accessory.7 The return air smoke detector may not fit up or work properly on the Precedent units

when used in conjunction with 3rd party accessories such as bolt on heat wheels,economizers and power exhaust. Do not order the return air smoke detectors whenusing this type of accessory.

Digit Description Order Number

9 Return Air Smoke Detector cannot be ordered with Novar Controls.0 These options are standard when ordering Novar Controls.q This option is used when ordering Novar Controls.w Includes gas piping and shutoff (field assembly required).e The manual outside air damper will ship factory supplied within the unit, but must be field

installed.r Requires Selection of 2" Pleated Filters (Option B or C) for Digit 16.t Through the base electric required when ordering disconnect/circuit breaker options.y Phase Monitor is standard on T/Y/WSC060A3,4,W models. All other models phase

monitor will be an option.u Not available with electro-mechanical controls.

Page 231: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PG-31 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Precedent™ Packaged Gas/ElectricConvertible 3-10 Tons

Table PG-31-A — AccessoriesModel Number Description Used WithyyyyyBAYABRD001C5 .................... ReliaTel™ Options Module ...................................................... See Note8BAYASCT0010e .................... Anti-Short-Cycle Timer ............................................................ Y*C036-060(A or E), Y*C072-120A_EBAYBARM011A7 .................... Barometric Relief ..................................................................... Y*C072-120ABAYBARM010A7 .................... Barometric Relief ..................................................................... Y*C036-060(A or E)BAYCCHT010B ........................ Crankcase Heater ................................................................... YSC048-060(A or E), YSC072A1,A3, Y*C092-120A3, YHC072A1,A3BAYCCHT011B ........................ Crankcase Heater ................................................................... YSC048-060(A or E), YSC072A4,AW, Y*C092-120A4,AW, YHC072A4,AWBAYCCHT012A ....................... Crankcase Heater ................................................................... Y*C090A3BAYCCHT013A ....................... Crankcase Heater ................................................................... Y*C090A4BAYCCHT014A ....................... Crankcase Heater ................................................................... Y*C090AWBAYCO2K001B5r ................ CO2 Sensor Kit, Wall Mounted ................................................ Y*C036-060(A or E), Y*C072-120A_RBAYCO2K003B5r ................ CO2 Sensor Kit, Duct Mounted ................................................ Y*C036-060(A or E), Y*C072-120A_RBAYCURB042A4 .................... Roof Curb ................................................................................ Y*C036-060(A or E)BAYCURB043A4 .................... Roof Curb ................................................................................ Y*C072-120ABAYDFPS003A58 ................. Clogged Filter Switch .............................................................. Y*C036-060(A or E), Y*C072-120A_RBAYDFPS004A58 ................. Fan Failure Switch ................................................................... Y*C036-060(A or E), Y*C072-120A_RBAYDMPR051A5 ................... 0-50% Motorized Outside Air Damper .................................... Y*C036-060(A or E)BAYDMPR052A0 ................... 0-50% Motorized Outside Air Damper .................................... Y*C036-060(A or E)_EBAYDMPR053Bt ................... 0-50% Manual Outside Air Damper ........................................ Y*C036-060(A or E)BAYDMPR054A5 ................... 0-50% Motorized Outside Air Damper .................................... Y*C072-120A_RBAYDMPR055A0 ................... 0-50% Motorized Outside Air Damper .................................... Y*C072-120A_EBAYDMPR056Bt ................... 0-50% Manual Outside Air Damper ........................................ Y*C072-120ABAYECON085A5 .................... 0-100% Dry Bulb Economizer without Barometric Relief ........ Y*C036-060(A or E)_RBAYECON086A0 .................... 0-100% Dry Bulb Economizer without Barometric Relief ........ Y*C036-060(A or E)_EBAYECON087A5 ................... 0-100% Dry Bulb Economizer without Barometric Relief ........ Y*C072-120A_RBAYECON088A0 ................... 0-100% Dry Bulb Economizer without Barometric Relief ........ Y*C072-120A_EBAYENTH005A1 .................... Reference Enthalpy Kit ............................................................ BAYECON085A, 087ABAYENTH006A1 .................... Comparative Enthalpy Kit ........................................................ BAYECON085A, 087ABAYENTH001A ........................ Enthalpy Control (Solid State .................................................. BAYECON086A, 088ABAYFRST001A56 ................. High Temperature Stat ............................................................. Y*C036-060(A or E), Y*072-120A_EBAYGARD036B ....................... Condenser Coil Hail Guard ..................................................... YSC036-060(A or E)**L,M, YHC036-048(A or E)**L,MBAYGARD037B ....................... Condenser Coil Hail Guard ..................................................... YSC036-060(A or E)**H, YHC036-048(A or E)**H,YHC060(A or E)**L,M,HBAYGARD040B ....................... Condenser Coil Hail Guard ..................................................... YSC072A,090A,092A,YHC072ABAYGARD041B ....................... Condenser Coil Hail Guard ..................................................... YSC102A,120A,YHC092,102A,120ABAYHAKT010B ........................ High Altitude Kit ....................................................................... Y*C036-060(A or E), Y*C072-120ABAYHSDR012A ....................... High Static Drive Kit ................................................................ Y*C072A,YSC090, 092ABAYHSMT073A ....................... .45 HP Oversized motor kit ..................................................... Y*C036(A or E)1,(A or E)3BAYHSMT074A ....................... .45 HP Oversized motor kit ..................................................... Y*C036(A or E)4BAYHSMT075A ....................... .45 HP Oversized motor kit ..................................................... Y*C036(A or E)WBAYHSMT076A ....................... .75 HP Oversized motor kit ..................................................... Y*C048(A or E)1,(A or E)3BAYHSMT077A ....................... .75 HP Oversized motor kit ..................................................... Y*C048(A or E)4BAYHSMT078A ....................... .75 HP Oversized motor kit ..................................................... Y*C048(A or E)WBAYHSMT079A ....................... 1.2 HP Oversized motor kit ..................................................... Y*C060(A or E)1,(A or E)3BAYHSMT080A ....................... 1.2 HP Oversized motor kit ..................................................... Y*C060(A or E)4BAYHSMT081A ....................... 1.2 HP Oversized motor kit ..................................................... Y*C060(A or E)WBAYHSMT082A ....................... 2 HP Oversized motor kit ........................................................ Y*C072A3,A4BAYHSMT083A ....................... 2 HP Oversized motor kit ........................................................ Y*C072AWBAYHSMT084A ....................... 3 HP Oversized motor kit ........................................................ YSC090,092A3, A4BAYHSMT085A ....................... 3 HP Oversized motor kit ........................................................ YSC090,092AWBAYHSMT086A ....................... 3 HP Oversized motor kit ........................................................ Y*C102A3,A4,YHC092A3, A4BAYHSMT087A ....................... 3 HP Oversized motor kit ........................................................ Y*C102AW,YHC092AWBAYHSMT088A ....................... 5 HP Oversized motor kit ........................................................ Y*C120A3,A4BAYHSMT089A ....................... 5 HP Oversized motor kit ........................................................ Y*C120AWBAYICSI003A5q .................... Trane Communications Interface (TCI) ................................... Y*C036-060(A or E), Y*C072-120A_RBAYKSKT255A ........................ Quick Start Kit ......................................................................... YSC048-060(A or E)1BAYKSKT256A ........................ Quick Start Kit ......................................................................... YSC036(A or E)1BAYLOAM020B28 ................ Evaporator Defrost Control (Frostat) ....................................... Y*C036-060(A or E)_RBAYLPKT028B ........................ LP Conversion Kit .................................................................... Y*C036-060(A or E), Y*C072L,M,Y*C090L,092L,Y*C102LBAYLPKT029A ........................ LP Conversion Kit .................................................................... Y*C072A**H, Y*C090,092,102A**M,H,Y*C120A**L,M,HBAYLTCI002B5 ....................... LonTalk® Communications Interface (LCI) .............................. Y*C036-060(A or E), Y*C072-120A_RBAYPWRX026Aw ................... Power Exhaust ........................................................................ Y*C072-120A3BAYPWRX027Aw ................... Power Exhaust ........................................................................ Y*C072-120A4BAYPWRX028Aw ................... Power Exhaust ........................................................................ Y*C072-120AWBAYQACB009A49 ................ Quick Adapt Curb .................................................................... Y*C036-060(A or E)BAYQACB010A49 ................ Quick Adapt Curb .................................................................... Y*C036-060(A or E)BAYQACB011A49 ................ Quick Adapt Curb .................................................................... Y*C072-120ABAYQACB012A49 ................ Quick Adapt Curb .................................................................... Y*C072-120ABAYQACB013A49 ................ Quick Adapt Curb .................................................................... Y*C072-120ABAYSENS016A5 .................... Temperature Sensor ................................................................ Y*C036-060(A or E), Y*C072-120A_RBAYSERV001A5 .................... Selective Resistance Service Tester ....................................... Y*C036-060(A or E)_RBAYSTAT0235 ........................ Remote Potentiometer ............................................................. BAYECON085ABAYTUBE004A538 ............. Discharge Air Sensing Kit ....................................................... Y*C036-060(A or E)_RBAYTUBE006A538 ............. Discharge Air Sensing Kit ....................................................... Y*C036-060(A or E), Y*C072-120A_RBAYVNOR001B5r8 ............ Ventilation Override Kit ............................................................ Y*C036-060(A or E), Y*C072-120A_R

1 Kits contain all necessary parts to achieve desired levelof enthalpy control.

2 For use with ReliaTel™ microprocessor controlled unitsonly. Must be factory installed for Electromechanicalcontrolled units.

3 Used for true discharge air sensing in both heating andcooling. Required for supply air tempering.

4 Lynn Haven Manufacturing has a No-Return policy forthis roof curb.

5 For use with ReliaTel™ controlled units only.6 Cannot be used in conjunction with factory installed

Smoke Detector option.7 Installs in ductwork for horizontal configuration. For

downflow configuration, it installs in the unit's horizontalreturn duct. See Installer's Guide for more information.

8 BAYABRD001C is required when ordering field installedaccessories Clogged Filter Switch (BAYDFPS003A), FanFail Switch (BAYDFPS004A),Discharge Air Sensing Kit(BAYTUBE004A or BAYTUBE005A) or EvaporatorDefrost Control (Frostat) (BAYLOAM020B) VentilationOverride Kit (BAYVNOR001B) unless the followingoptions are factory installed: Frostat, Smoke Detector,Clogged Filter Switch, Fan Failure Switch, Discharge AirSensing Kit. These factory installed options includethe ReliaTel™ Options Module.

9 BAYQACB009A adapts Voyager BAYCURB021B toaccept Precedent 3 -5 ton unit. BAYQACB010A adaptsVoyager BAYCURB022B to accept Precedent 3-5 tonunit. BAYQACB012A adapts Voyager BAYCURB025B toaccept Precedent 6-10 ton unit. BAYQACB013A adapts

Voyager BAYCURB026B to accept Precedent 6-10 tonunit.BAYQACB011A adapts Voyager BAYCURB022B toaccept Precedent 6-10 ton unit.

0 Electromechanical controlled units onlyq Interface allows 3-10 ton units with ReliaTel™ Controls

to communicate with Tracer 100, Tracker, VariTrac II,and is the preferred method of communication to TracerSummit.

w Power Exhaust cannot be used with Barometric Relief.Order Economizer without Barometric Relief.

e Activated on Power on.r Field installed accessory. Requires an economizer.t The manual outside air damper will ship factory supplied

within the unit, but must be field installed.y A=R-22, E=410A

Page 232: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PG-32Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Table PG-32-A — Zone Sensors for ReliaTel™ Controlled UnitsModelNumber Description Used with

BAYSENS006B ...... Single Setpoint Manual Changeover .................................... Y*C036-120A_RBAYSENS008B ...... Dual Setpoint Manual or Auto Changeover .......................... Y*C036-120A_RBAYSENS010B ...... Dual Setpoint Man. or Auto Change-over with System ........ Y*C036-120A_R

Function LightsBAYSENS019C ...... Programmable Night Setback w/System Function Lights ..... Y*C036-120A_RBAYSENS013C1 ... Room Sensor w/ Override and Cancel Buttons .................... Y*C036-120A_RBAYSENS014C1 ... Room Sensor w/ Temp. Adjustment with Override and ........ Y*C036-120A_R

Cancel ButtonsBAYSENS017B ...... Remote Room Sensor .......................................................... BAYSENS006B,008B,010B,019CBAYSENS032A5 ... Dual Thermistor Remote Zone Sensor ................................. Y*C036-120A_RBAYSENS035A5 ... Digital Display Zone Sensor ................................................. Y*C036-120A_RBAYSENS036A4 ... Wall-Mounted Humidity Zone Sensor ................................... YHC120,3,4,WRBAYSENS037A4 ... Duct-Mounted Humidity Zone Sensor ................................... YHC120,3,4,WRBAYMTPL003B ...... Retrofit Wall Cover Plate Kit 7.25" x 6.0" .............................. BAYSENS019CBAYMTPL004B ...... Retrofit Wall Cover Plate Kit 4.75" x 4.75" ............................ BAYSENS006B,007B,010B,

013,014C,017B

Precedent™ Packaged Gas/ElectricConvertible 3-10 Tons

Table PG-32-B — ThermostatsModelNumber Description Used with

BAY28X1903 ............ Locking Thermostat Cover .................................................... Room ThermostatsBAYSTAT040B2 ..... Programmable Thermostat ................................................... Y*C036-120ATCONT200AN11AA Electronic, 1 Htg/1 CLG (non-prog) ...................................... Y*C036-090ABAYBASE008A ....... Subbase 1-Stage Heating/Cooling ........................................ BAYSTAT040BBAYBASE006A ....... Subbase 2-Stage Heating/Cooling ........................................ BAYSTAT040BBAYSENS033A ....... Remote Wall Sensor ............................................................. BAYSTAT040BBAYSENS034A ....... Remote Duct Sensor ............................................................ BAYSTAT040BBAYSTAT008 ........... Manual 1-Stage Heating/Cooling .......................................... Y*C036-120ABAYSTAT010 .......... Auto 2-Stage Heating/Cooling .............................................. Y*C036-120A

1 Used with Integrated ComfortTM Systems, any unit type. These sensors do not work with TCM. Consult BASD Marketing for them.2 Requires use of BAYBASE006A or BAYBASE008A.3 Do not use with Programmable Thermostats.4 For use with Dehumidification (Hot Gas Reheat) Coil Option.5 For use with ReliaTel™ Controls only.* Either standard or high efficiency models.

For additional Controls Information:See ReliaTel™ and Micro Control features on PC-35 and PC-36

Page 233: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PG-33 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Light Commercial Gas Electrics NewModel Number Quick Reference

Table PG-33-A — Quick Reference

Precedent™ Precedent™Voyager Horizontal Voyager Downflow Controls Ordering Number Service Model Number

YCD036C1L0B Micro-Proc YSC036*1RLA0000 YSC036*1RLA**000000000000Electro-Mech YSC036*1ELA0000 YSC036*1ELA**000000000000

Medium Heat Micro-Proc YSC036*1RMA0000 YSC036*1RMA**000000000000Electro-Mech YSC036*1EMA0000 YSC036*1EMA**000000000000

YCD036C1H0B Micro-Proc YSC036*1RHA0000 YSC036*1RHA**000000000000Electro-Mech YSC036*1EHA0000 YSC036*1EHA**000000000000

YCD036C3L0B Micro-Proc YSC036*3RLA0000 YSC036*3RLA**000000000000Electro-Mech YSC036*3ELA0000 YSC036*3ELA**000000000000

Medium Heat Micro-Proc YSC036*3RMA0000 YSC036*3RMA**000000000000Electro-Mech YSC036*3EMA0000 YSC036*3EMA**000000000000

YCD036C3H0B Micro-Proc YSC036*3RHA0000 YSC036*3RHA**000000000000Electro-Mech YSC036*3EHA0000 YSC036*3EHA**000000000000

YCD036C4L0B Micro-Proc YSC036*4RLA0000 YSC036*3RLA**000000000000Electro-Mech YSC036*4ELA0000 YSC036*3ELA**000000000000

Medium Heat Micro-Proc YSC036*4RMA0000 YSC036*3RMA**000000000000Electro-Mech YSC036*4EMA0000 YSC036*3EMA**000000000000

YCD036C4H0B Micro-Proc YSC036*4RHA0000 YSC036*4RHA**000000000000Electro-Mech YSC036*4EHA0000 YSC036*4EHA**000000000000

YCH048C1L0B YCD048C1L0B Micro-Proc YSC048*1RLA0000 YSC048*1RLA**000000000000Electro-Mech YSC048*1ELA0000 YSC048*1ELA**000000000000

Medium Heat Micro-Proc YSC048*1RMA0000 YSC048*1RMA**000000000000Electro-Mech YSC048*1EMA0000 YSC048*1EMA**000000000000

YCH048C1H0B YCD048C1H0B Micro-Proc YSC048*1RHA0000 YSC048*1RHA**000000000000Electro-Mech YSC048*1EHA0000 YSC048*1EHA**000000000000

YCH048C3L0B YCD048C3L0B Micro-Proc YSC048*3RLA0000 YSC048*3RLA**000000000000Electro-Mech YSC048*3ELA0000 YSC048*3ELA**000000000000

Medium Heat Micro-Proc YSC048*3RMA0000 YSC048*3RMA**000000000000Electro-Mech YSC048*3EMA0000 YSC048*3EMA**000000000000

YCH048C3H0B YCD048C3H0B Micro-Proc YSC048*3RHA0000 YSC048*3RHA**000000000000Electro-Mech YSC048*3EHA0000 YSC048*3EHA**000000000000

YCH048C4L0B YCD048C4L0B Micro-Proc YSC048*4RLA0000 YSC048*4RLA**000000000000Electro-Mech YSC048*4ELA0000 YSC048*4ELA**000000000000

Medium Heat Micro-Proc YSC048*4RMA0000 YSC048*4RMA**000000000000Electro-Mech YSC048*4EMA0000 YSC048*4EMA**000000000000

YCH048C4H0B YCD048C4H0B Micro-Proc YSC048*4RHA0000 YSC048*4RHA**000000000000Electro-Mech YSC048*4EHA0000 YSC048*4EHA**000000000000

YCH048CWL0B YCD048CWL0B Micro-Proc YSC048*WRLA0000 YSC048*WRLA**000000000000Electro-Mech YSC048*WELA0000 YSC048*WELA**000000000000

Medium Heat Micro-Proc YSC048*WRMA0000 YSC048*WRMA**000000000000Electro-Mech YSC048*WEMA0000 YSC048*WEMA**000000000000

YCH048CWH0B YCD048CWH0B Micro-Proc YSC048*WRHA0000 YSC048*WRHA**000000000000Electro-Mech YSC048*WEHA0000 YSC048*WEHA**000000000000

NOTE: N/A indicates that an Ordering Number has not yet been set up for the indicated model.* Digit 7- A=R-22, E=410A.

Page 234: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PG-34Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Table PG-34-A — Quick Reference

Precedent™ Precedent™Voyager Horizontal Voyager Downflow Controls Ordering Number Service Model Number

Light Commercial Gas Electrics NewModel Number Quick Reference

YCH060C1L0B YCD060C1L0B Micro-Proc YSC060*1RLA0000 YSC060*1RLA**000000000000Electro-Mech YSC060*1ELA0000 YSC060*1ELA**000000000000

Medium Heat Micro-Proc YSC060*1RMA0000 YSC060*1RMA**000000000000Electro-Mech YSC060*1EMA0000 YSC060*1EMA**000000000000

YCH060C1H0B YCD060C1H0B Micro-Proc YSC060*1RHA0000 YSC060*1RHA**000000000000Electro-Mech YSC060*1EHA0000 YSC060*1EHA**000000000000

YCH060C3L0B YCD060C3L0B Micro-Proc YSC060*3RLA0000 YSC060*3RLA**000000000000Electro-Mech YSC060*3ELA0000 YSC060*3ELA**000000000000

Medium Heat Micro-Proc YSC060*3RMA0000 YSC060*3RMA**000000000000Electro-Mech YSC060*3EMA0000 YSC060*3EMA**000000000000

YCH060C3H0B YCD060C3H0B Micro-Proc YSC060*3RHA0000 YSC060*3RHA**000000000000Electro-Mech YSC060*3EHA0000 YSC060*3EHA**000000000000

YCH060C4L0B YCD060C4L0B Micro-Proc YSC060*4RLA0000 YSC060*4RLA**000000000000Electro-Mech YSC060*4ELA0000 YSC060*4ELA**000000000000

Medium Heat Micro-Proc YSC060*4RMA0000 YSC060*4RMA**000000000000Electro-Mech YSC060*4EMA0000 YSC060*4EMA**000000000000

YCH060C4H0B YCD060C4H0B Micro-Proc YSC060*4RHA0000 YSC060*4RHA**000000000000Electro-Mech YSC060*4EHA0000 YSC060*4EHA**000000000000

YCH060CWL0B YCD060CWL0B Micro-Proc YSC060*WRLA0000 YSC060*WRLA**000000000000Electro-Mech YSC060*WELA0000 YSC060*WELA**000000000000

Medium Heat Micro-Proc YSC060*WRMA0000 YSC060*WRMA**000000000000Electro-Mech YSC060*WEMA0000 YSC060*WEMA**000000000000

YCH060CWH0B YCD060CWH0B Micro-Proc YSC060*WRHA0000 YSC060*WRHA**000000000000Electro-Mech YSC060*WEHA0000 YSC060*WEHA**000000000000

YCH074C3L0B YCD074C3L0B Micro-Proc YSC072*3RLA0000 YSC072*3RLA**000000000000Electro-Mech YSC072*3ELA0000 YSC072*3ELA**0000000000000

Medium Heat Micro-Proc YSC072*3RMA0000 YSC072*3RMA**000000000000Electro-Mech YSC072*3EMA0000 YSC072*3EMA**000000000000

YCH074C3H0B YCD074C3H0B Micro-Proc YSC072*3RHA0000 YSC072*3RHA**000000000000Electro-Mech YSC072*3EHA0000 YSC072*3EHA**000000000000

YCH074C4L0B YCD074C4L0B Micro-Proc YSC072*4RLA0000 YSC072*3RLA**000000000000Electro-Mech YSC072*4ELA0000 YSC072*3ELA**000000000000

Medium Heat Micro-Proc YSC072*4RMA0000 YSC072*3RMA**000000000000Electro-Mech YSC072*4EMA0000 YSC072*3EMA**000000000000

YCH074C4H0B YCD074C4H0B Micro-Proc YSC072*4RHA0000 YSC072*4RHA**000000000000Electro-Mech YSC072*4EHA0000 YSC072*4EHA**000000000000

Low Heat Micro-Proc YSC072*WRLA0000 YSC072*WRLA**000000000000Electro-Mech YSC072*WELA0000 YSC072*WELA**000000000000

Medium Heat Micro-Proc YSC072*WRMA0000 YSC072*WRMA**000000000000Electro-Mech YSC072*WEMA0000 YSC072*WEMA**000000000000

High Heat Micro-Proc YSC072*WRHA0000 YSC072*WRHA**000000000000Electro-Mech YSC072*WEHA0000 YSC072*WEHA**000000000000

YCH075C3L0B YCD075C3L0B Micro-Proc YHC072*3RLA0000 YHC072*3RLA**000000000000Electro-Mech YHC072*3ELA0000 YHC072*3ELA**000000000000

Medium Heat Micro-Proc YHC072*3RMA0000 YHC072*3RMA**000000000000Electro-Mech YHC072*3EMA0000 YHC072*3EMA**000000000000

YCH075C3H0B YCD075C3H0B Micro-Proc YHC072*3RHA0000 YHC072*3RHA**000000000000Electro-Mech YHC072*3EHA0000 YHC072*3EHA**000000000000

YCH075C4L0B YCD075C4L0B Micro-Proc YHC072*4RLA0000 YHC072*3RLA**000000000000Electro-Mech YHC072*4ELA0000 YHC072*3ELA**000000000000

Medium Heat Micro-Proc YHC072*4RMA0000 YHC072*3RMA**000000000000Electro-Mech YHC072*4EMA0000 YHC072*3EMA**000000000000

YCH075C4H0B YCD075C4H0B Micro-Proc YHC072*4RHA0000 YHC072*4RHA**000000000000Electro-Mech YHC072*4EHA0000 YHC072*4EHA**000000000000

NOTE: N/A indicates that an Ordering Number has not yet been set up for the indicated model.* Digit 7- A=R-22, E=410A.

Page 235: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PG-35 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

YCH075CWL0B YCD075CWL0B Micro-Proc YHC072AWRHA0000 YHC072AWRHA**000000000000Electro-Mech YHC072AWEHA0000 YHC072AWEHA**000000000000

Medium Heat Micro-Proc YHC072AWRMA0000 YHC072AWRMA**000000000000Electro-Mech YHC072AWEMA0000 YHC072AWEMA**000000000000

YCH075CWH0B YCD075CWH0B Micro-Proc YHC072AWRLA0000 YHC072A3RLA**000000000000Electro-Mech YHC072AWELA0000 YHC072A3ELA**000000000000

YCH090D3L0B YCD090D3L0B Micro-Proc YSC090A3RLA0000 YSC090A3RLA**000000000000Electro-Mech YSC090A3ELA0000 YSC090A3ELA**000000000000

Medium Heat Micro-Proc YSC090A3RMA0000 YSC090A3RMA**000000000000Electro-Mech YSC090A3EMA0000 YSC090A3EMA**000000000000

YCH090D3H0B YCD090D3H0B Micro-Proc YSC090A3RHA0000 YSC090A3RHA**000000000000Electro-Mech YSC090A3EHA0000 YSC090A3EHA**000000000000

YCH090D4L0B YCD090D4L0B Micro-Proc YSC090A4RLA0000 YSC090A4RLA**000000000000Electro-Mech YSC090A4ELA0000 YSC090A4ELA**000000000000

Medium Heat Micro-Proc YSC090A4RMA0000 YSC090A4RMA**000000000000Electro-Mech YSC090A4EMA0000 YSC090A4EMA**000000000000

YCH090D4H0B YCD090D4H0B Micro-Proc YSC090A4RHA0000 YSC090A4RHA**000000000000Electro-Mech YSC090A4EHA0000 YSC090A4EHA**000000000000

YCH090DWL0B YCD090DWL0B Micro-Proc YSC090AWRLA0000 YSC090AWRLA**000000000000Electro-Mech YSC090AWELA0000 YSC090AWELA**000000000000

Medium Heat Micro-Proc YSC090AWRMA0000 YSC090AWRMA**000000000000Electro-Mech YSC090AWEMA0000 YSC090AWEMA**000000000000

YCH090DWH0B YCD090DWH0B Micro-Proc YSC090AWRHA0000 YSC090AWRHA**000000000000Electro-Mech YSC090AWEHA0000 YSC090AWEHA**000000000000

YCH091D3L0B YCD091D3L0B Micro-Proc YHC090A3RLA**000000000000Electro-Mech YHC090A3ELA**000000000000

Medium Heat Micro-Proc YHC090A3RMA**000000000000Electro-Mech YHC090A3EMA**000000000000

YCH091D3H0B YCD091D3H0B Micro-Proc YHC090A3RHA**000000000000Electro-Mech YHC090A3EHA**000000000000

YCH091D4L0B YCD091D4L0B Micro-Proc YHC090A4RLA**000000000000Electro-Mech YHC090A4ELA**000000000000

Medium Heat Micro-Proc YHC090A4RMA**000000000000Electro-Mech YHC090A4EMA**000000000000

YCH091D4H0B YCD091D4H0B Micro-Proc YHC090A4RHA**000000000000Electro-Mech YHC090A4EHA**000000000000

Low Heat Micro-Proc YHC090AWRLA**000000000000Electro-Mech YHC090AWELA**000000000000

Medium Heat Micro-Proc YHC090AWRMA**000000000000Electro-Mech YHC090AWEMA**000000000000

High Heat Micro-Proc YHC090AWRHA**000000000000Electro-Mech YHC090AWEHA**000000000000

YCH102C3L0A YCD102C3L0A Micro-Proc YSC102A3RLA0000 YSC102A3RLA**000000000000Electro-Mech YSC102A3ELA0000 YSC102A3ELA**000000000000

Medium Heat Micro-Proc YSC102A3RMA**000000000000Electro-Mech YSC102A3EMA0000 YSC102A3EMA**000000000000

YCH102C3H0A YCD102C3H0A Micro-Proc YSC102A3RHA0000 YSC102A3RHA**000000000000Electro-Mech YSC102A3EHA0000 YSC102A3EHA**000000000000

YCH102C4L0A YCD102C4L0A Micro-Proc YSC102A4RLA0000 YSC102A4RLA**000000000000Electro-Mech YSC102A4ELA0000 YSC102A4ELA**000000000000

Medium Heat Micro-Proc YSC102A4RMA0000 YSC102A4RMA**000000000000Electro-Mech YSC102A4EMA0000 YSC102A4EMA**000000000000

YCH102C4H0A YCD102C4H0A Micro-Proc YSC102A4RHA0000 YSC102A4RHA**000000000000Electro-Mech YSC102A4EHA0000 YSC102A4EHA**000000000000

YCH102CWL0A YCD102CWL0A Micro-Proc YSC102AWRLA0000 YSC102AWRLA**000000000000Electro-Mech YSC102AWELA0000 YSC102AWELA**000000000000

Medium Heat Micro-Proc YSC102AWRMA0000 YSC102AWRMA**000000000000Electro-Mech YSC102AWEMA0000 YSC102AWEMA**000000000000

YCH102CWH0A YCD102CWH0A Micro-Proc YSC102AWRHA0000 YSC102AWRHA**000000000000Electro-Mech YSC102AWEHA0000 YSC102AWEHA**000000000000

YCH103C3L0A YCD103C3L0A Micro-Proc YHC102A3RLA0000 YHC102A3RLA**000000000000Electro-Mech YHC102A3ELA0000 YHC102A3ELA**000000000000

Medium Heat Micro-Proc YHC102A3RMA0000 YHC102A3RMA**000000000000Electro-Mech YHC102A3EMA0000 YHC102A3EMA**000000000000

YCH103C3H0A YCD103C3H0A Micro-Proc YHC102A3RHA0000 YHC102A3RHA**000000000000Electro-Mech YHC102A3EHA0000 YHC102A3EHA**000000000000

NOTE: N/A indicates that an Ordering Number has not yet been set up for the indicated model.

Table PG-35-A — Quick Reference

Precedent™ Precedent™Voyager Horizontal Voyager Downflow Controls Ordering Number Service Model Number

Light Commercial Gas Electrics NewModel Number Quick Reference

Page 236: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PG-36Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Table PG-36-A — Quick Reference

Precedent™ Precedent™Voyager Horizontal Voyager Downflow Controls Ordering Number Service Model Number

YCH103C4L0A YCD103C4L0A Micro-Proc YHC102A4RLA0000 YHC102A4RLA**000000000000Electro-Mech YHC102A4ELA0000 YHC102A4ELA**000000000000

Medium Heat Micro-Proc YHC102A4RMA0000 YHC102A4RMA**000000000000Electro-Mech YHC102A4EMA0000 YHC102A4EMA**000000000000

YCH103C4H0A YCD103C4H0A Micro-Proc YHC102A4RHA0000 YHC102A4RHA**000000000000Electro-Mech YHC102A4EHA0000 YHC102A4EHA**000000000000

YCH103CWL0A YCD103CWL0A Micro-Proc YHC102A4RLA0000 YHC102A4RLA**000000000000Electro-Mech YHC102A4ELA0000 YHC102A4ELA**000000000000

Medium Heat Micro-Proc YHC102A4RMA0000 YHC102A4RMA**000000000000Electro-Mech YHC102A4EMA0000 YHC102A4EMA**000000000000

YCH103CWH0A YCD103CWH0A Micro-Proc YHC102A4RHA0000 YHC102A4RHA**000000000000Electro-Mech YHC102A4EHA0000 YHC102A4EHA**000000000000

YCH120C3L0A YCD120C3L0A Micro-Proc YSC120A3RLA0000 YSC120A3RLA**000000000000Electro-Mech YSC120A3ELA0000 YSC120A3ELA**000000000000

YCH120C3M0A YCD120C3M0A Micro-Proc YSC120A3RMA0000 YSC120A3RMA**000000000000Electro-Mech YSC120A3EMA0000 YSC120A3EMA**000000000000

YCH120B3H0E YCD120B3H0E Micro-Proc YSC120A3RHA0000 YSC120A3RHA**000000000000Electro-Mech YSC120A3EHA0000 YSC120A3EHA**000000000000

YCH120C4L0A YCD120C4L0A Micro-Proc YSC120A4RLA0000 YSC120A4RLA**000000000000Electro-Mech YSC120A4ELA0000 YSC120A4ELA**000000000000

YCH120C4M0A YCD120C4M0A Micro-Proc YSC120A4RMA0000 YSC120A4RMA**000000000000Electro-Mech YSC120A4EMA0000 YSC120A4EMA**000000000000

YCH120B4H0E YCD120B4H0E Micro-Proc YSC120A4RHA0000 YSC120A4RHA**000000000000Electro-Mech YSC120A4EHA0000 YSC120A4EHA**000000000000

YCH120CWL0A YCD120CWL0A Micro-Proc YSC120AWRLA0000 YSC120AWRLA**000000000000Electro-Mech YSC120AWELA0000 YSC120AWELA**000000000000

YCH120CWM0A YCD120CWM0A Micro-Proc YSC120AWRMA0000 YSC120AWRMA**000000000000Electro-Mech YSC120AWEMA0000 YSC120AWEMA**000000000000

YCH120BWH0E YCD120BWH0E Micro-Proc YSC120AWRHA0000 YSC120AWRHA**000000000000Electro-Mech YSC120AWEHA0000 YSC120AWEHA**000000000000

YCH121C3L0A YCD121C3L0A Micro-Proc YHC120A3RLA0000 YHC120A3RLA**000000000000Electro-Mech YHC120A3ELA0000 YHC120A3ELA**000000000000

Medium Heat Micro-Proc YHC120A3RMA0000 YHC120A3RMA**000000000000Electro-Mech YHC120A3EMA0000 YHC120A3EMA**000000000000

YCH121C3H0A YCD121C3H0A Micro-Proc YHC120A3RHA0000 YHC120A3RHA**000000000000Electro-Mech YHC120A3EHA0000 YHC120A3EHA**000000000000

YCH121C4L0A YCD121C4L0A Micro-Proc YHC120A4RLA0000 YHC120A4RLA**000000000000Electro-Mech YHC120A4ELA0000 YHC120A4ELA**000000000000

Medium Heat Micro-Proc YHC120A4RMA0000 YHC120A4RMA**000000000000Electro-Mech YHC120A4EMA0000 YHC120A4EMA**000000000000

YCH121C4H0A YCD121C4H0A Micro-Proc YHC120A4RHA0000 YHC120A4RHA**000000000000Electro-Mech YHC120A4EHA0000 YHC120A4EHA**000000000000

YCH121CWL0A YCD121CWL0A Micro-Proc YHC120AWRLA0000 YHC120AWRLA**000000000000Electro-Mech YHC120AWELA0000 YHC120AWELA**000000000000

Medium Heat Micro-Proc YHC120AWRMA0000 YHC120AWRMA**000000000000Electro-Mech YHC120AWEMA0000 YHC120AWEMA**000000000000

YCH121CWH0A YCD121CWH0A Micro-Proc YHC120AWRHA0000 YHC120AWRHA**000000000000Electro-Mech YHC120AWEHA0000 YHC120AWEHA**000000000000

NOTE: N/A indicates that an Ordering Number has not yet been set up for the indicated mode

Light Commercial Gas Electrics NewModel Number Quick Reference

See ReliaTel™ and Micro Control features on PC-35 and PC-36.

Page 237: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PG-37 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Standard Features:• Trane built scroll compressors on all 3-5 ton units• Colored and numbered wiring• Provisions for through the Base Gas and Condensate Drain Connections• Patented Hybrid Condenser Coil for easy cleaning• 1" throwaway filters provided on 3-5 ton units• Liquid Line Refrigerant Drier• Operating Charge of R-22• IAQ Sloped Drain Pans• Low Ambient to 40°F on Electromechanical models• Low Ambient to 0°F on Microprocessor models• 5 - year Limited Compressor Warranty• 5 - year Limited Heat Exchanger Warranty• 1 - year Limited Parts Warranty

Added Flexibility

• Electromechanical or microprocessor controls (See page PC-35 for ReliaTel™Control Information)

• Low, medium or high heat, single or two stage• Convertible airflow• Fork lift openings on three sides of unit• Belt drive - standard or oversized motors• We don’t prepackage options• Choose options tailored to suit each job —pay only for what is needed• Units ship with options installed —and within our standard ship cycle time

Factory Installed Options

• Through-the-Base — Electrical• Convenience Outlet — Powered or unpowered• Unit Disconnect Switch• Smoke Detectors — Supply, return, or both• Condenser Coil Coating• Hinged Access Service Panels• Discharge Air Sensor• Fan Fail and Clogged Filter Switches• Condenser Coil Guard — Hail Protection Quality• Hot Gas Reheat Coil - Dehumidification• TXV thermal expansion valve and split face evaporator coil standard• TCI (Trane Communication Interface)• LonTalk (Communication Interface)• 2" Pleated Media filters• Phase Monitor• Frostat

The same Trane Quality andReliability … with added Flexibility!

Precedent™ 3-5 ton 13 SEER R-22Packaged Gas Electrics

FeaturingA New Look for a New Century

Beveled TopSmoother DesignSmall compact cabinetRecessed access handles

Page 238: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PG-38Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Precedent™ Packaged Gas/ElectricConvertible 3-5 Tons 13 SEER R-22

Table PG-38-A — Base Unit — 13 SEER High Efficiency — ElectromechanicalHeating Output11111 Cabinet Shipping

Unit Performance33333 Cooling Capacity Dimensions (in.) Downflow Downflow Weight Max.2Tons Ordering No. SEER/EER Capacity (Btuh) (Btuh) AFUE% H x W x L Supply Return (Ibs.) MCA* Fuse*

YHC –208-230/3/60 – Three Phase – Low Heat3 YHC033A3ELA0000 13.0 38,000 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 620 19.9 304 YHC043A3ELA0000 13.0 49,800 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 662 22.6 355 YHC063A3ELA0000 13.0 62,400 48,000 81 36 x 44 x 70 18 x 15.5 24 x 14 697 28.8 45

YHC –460/3/60 – Three Phase – Low Heat3 YHC033A4ELA0000 13.0 38,000 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 620 10.4 154 YHC043A4ELA0000 13.0 49,800 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 662 11.8 155 YHC063A4ELA0000 13.0 62,400 48,000 81 36 x 44 x 70 18 x 15.5 24 x 14 697 14.3 20

YHC –575/3/60 – Three Phase – Low Heat3 YHC033AWELA0000 13.0 38,000 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 620 7.7 154 YHC043AWELA0000 13.0 49,800 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 662 8.5 155 YHC063AWELA0000 13.0 62,400 48,000 81 36 x 44 x 70 18 x 15.5 24 x 14 697 11.4 15

YHC –208-230/3/60 – Three Phase – Medium Heat3 YHC033A3EMA0000 13.0 38,000 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 620 19.9 304 YHC043A3EMA0000 13.0 49,800 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 662 22.6 355 YHC063A3EMA0000 13.0 62,400 64,000 81 36 x 44 x 70 18 x 15.5 24 x 14 697 28.8 45

YHC –460/3/60 – Three Phase – Medium Heat3 YHC033A4EMA0000 13.0 38,000 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 620 10.4 154 YHC043A4EMA0000 13.0 49,800 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 662 11.8 155 YHC063A4EMA0000 13.0 62,400 64,000 81 36 x 44 x 70 18 x 15.5 24 x 14 697 14.3 20

YHC –575/3/60 – Three Phase – Medium Heat3 YHC033AWEMA0000 13.0 38,000 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 620 7.7 154 YHC043AWEMA0000 13.0 49,800 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 662 8.5 155 YHC063AWEMA0000 13.0 62,400 64,000 81 36 x 44 x 70 18 x 15.5 24 x 14 697 11.4 15

YHC –208-230/3/60 – Three Phase – High Heat3 YHC033A3EHA0000 13.0 38,000 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 620 19.9 304 YHC043A3EHA0000 13.0 49,800 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 662 22.6 355 YHC063A3EHA0000 13.0 62,400 104,000 80 36 x 44 x 70 18 x 15.5 24 x 14 697 28.8 45

YHC –460/3/60 – Three Phase – High Heat3 YHC033A4EHA0000 13.0 38,000 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 620 10.4 154 YHC043A4EHA0000 13.0 49,800 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 662 11.8 15

YHC063A4EHA0000 13.0 62,400 104,000 80 36 x 44 x 70 18 x 15.5 24 x 14 697 14.3 20

YHC –575/3/60 – Three Phase – High Heat3 YHC033AWEHA0000 13.0 38,000 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 620 7.7 154 YHC043AWEHA0000 13.0 49,800 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 662 8.5 155 YHC063AWEHA0000 13.0 62,400 104,000 80 36 x 44 x 70 18 x 15.5 24 x 14 697 11.4 15

* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.1 Downflow Airflow/Horizontal Airflow2 HCAR Breaker per NEC.3 SEER applies, 3-5 tons; EER applies 6-10 tons.

Page 239: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PG-39 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Precedent™ Packaged Gas/ElectricConvertible 3-5 Tons 13 SEER R-22

Table PG-39-A — Base Unit — 13 SEER High Efficiency — ReliaTel™ Microprocessor ControlsHeating Output11111 Cabinet Shipping

Unit Performance33333 Cooling Capacity Dimensions (in.) Downflow Downflow Weight Max.2Tons Ordering No. SEER/EER Capacity (Btuh) (Btuh) AFUE% H x W x L Supply Return (Ibs.) MCA* Fuse*

YHC –208-230/3/60 – Three Phase – Low Heat3 YHC033A3RLA0000 13.0 38,000 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 620 19.9 304 YHC043A3RLA0000 13.0 49,800 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 662 22.6 355 YHC063A3RLA0000 13.0 62,400 48,000 81 36 x 44 x 70 18 x 15.5 24 x 14 697 28.8 45

YHC –460/3/60 – Three Phase – Low Heat3 YHC033A4RLA0000 13.0 38,000 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 620 10.4 154 YHC043A4RLA0000 13.0 49,800 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 662 11.8 155 YHC063A4RLA0000 13.0 62,400 48,000 81 36 x 44 x 70 18 x 15.5 24 x 14 697 14.3 20

YHC –575/3/60 – Three Phase – Low Heat3 YHC033AWRLA0000 13.0 38,000 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 620 7.7 154 YHC043AWRLA0000 13.0 49,800 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 662 8.5 155 YHC063AWRLA0000 13.0 62,400 48,000 81 36 x 44 x 70 18 x 15.5 24 x 14 697 11.4 15

YHC –208-230/3/60 – Three Phase – Medium Heat3 YHC033A3RMA0000 13.0 38,000 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 620 19.9 304 YHC043A3RMA0000 13.0 49,800 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 662 22.6 355 YHC063A3RMA0000 13.0 62,400 64,000 81 36 x 44 x 70 18 x 15.5 24 x 14 697 28.8 45

YHC –460/3/60 – Three Phase – Medium Heat3 YHC033A4RMA0000 13.0 38,000 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 620 10.4 154 YHC043A4RMA0000 13.0 49,800 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 662 11.8 155 YHC063A4RMA0000 13.0 62,400 64,000 81 36 x 44 x 70 18 x 15.5 24 x 14 697 14.3 20

YHC –575/3/60 – Three Phase – Medium Heat3 YHC033AWRMA0000 13.0 38,000 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 620 7.7 154 YHC043AWRMA0000 13.0 49,800 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 662 8.5 155 YHC063AWRMA0000 13.0 62,400 64,000 81 36 x 44 x 70 18 x 15.5 24 x 14 697 11.4 15

YHC –208-230/3/60 – Three Phase – High Heat3 YHC033A3RHA0000 13.0 38,000 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 620 19.9 304 YHC043A3RHA0000 13.0 49,800 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 662 22.6 355 YHC063A3RHA0000 13.0 62,400 104,000 80 36 x 44 x 70 18 x 15.5 24 x 14 697 28.8 45

YHC –460/3/60 – Three Phase – High Heat3 YHC033A4RHA0000 13.0 38,000 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 620 10.4 154 YHC043A4RHA0000 13.0 49,800 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 662 11.8 155 YHC063A4RHA0000 13.0 62,400 104,000 80 36 x 44 x 70 18 x 15.5 24 x 14 697 14.3 20

YHC –575/3/60 – Three Phase – High Heat3 YHC033AWRHA0000 13.0 38,000 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 620 7.7 154 YHC043AWRHA0000 13.0 49,800 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 662 8.5 155 YHC063AWRHA0000 13.0 62,400 104,000 80 36 x 44 x 70 18 x 15.5 24 x 14 697 11.4 15

* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.1 Downflow Airflow/Horizontal Airflow2 HCAR Breaker per NEC.3 SEER applies, 3-5 tons; EER applies 6-10 tons.

Page 240: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PG-40Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Digit Description Order Number1-8 Main Assembly (see previous page)9 Unit Controls

Electromechanical .................................................... EUnit Controls -ReliaTel™ Micro-processor .................. R

10 Heating CapacityLow ......................................................................... LMedium .................................................................. MHigh ......................................................................... H

11 Minor Design Sequence First Sequence ........................................................ A

12-13 Service SequenceFirst Sequence (Factory assigned) .......................... ✱,✱

14 Fresh Air SelectionNo Fresh Air ............................................................. 00-50% Manual Outside Air Dampere ......................... A0-50% Motorized Outside Air Damper ........................ B0-100% Economizer, Dry Bulb without

Barometric Relief2 ................................................ C0-100% Economizer, Dry Bulb with

Barometric Relief2 ............................................... D0-100% Economizer, Reference Enthalpy

without Barometric Relief12 .................................. E0-100%Economizer, Reference Enthalpy

with Barometric Relief12 ....................................... F0-100%Economizer, Comparative Enthalpy

without Barometric Relief 12 ................................ G0-100%Economizer, Comparative Enthalpy

with Barometric Relief 12 ...................................... H15 Supply Fan/Drive Type/Motor

Standard Drive ......................................................... 016 Hinged Service Access & Filters

Standard Panels & Filters ......................................... 0Hinged Access Panels & Standard Filters .................. AStandard panels & 2" Pleated Filters .......................... BHinged Access Panels & 2" Pleated Filters ................ C

17 Condenser Coil ProtectionStandard Coil ........................................................... 0Standard Coil with Hail Guard ................................... 1Epoxy Coated Condenser Coil .................................. 2Epoxy Coated Condenser Coil with Hail Guard .......... 3

18 Through the Base ProvisionsNo Through the Base Provisions ............................... 0Through the Base Electrict ...................................... AThrough the Base Gas ............................................. BThrough the Base Gas and Electricw ........................ C

19 Disconnect/Circuit Breaker/Phase Monitor (3 phase only)No Disconnect Circuit Breaker/No Phase Monitor ....... 0Non-Fused Disconnectt ........................................... 1Circuit Breakert ....................................................... 2Phase Monitory ....................................................... 3Phase Monitory & Non-Fused Disconnect Switch ...... 4Phase Monitory & Circuit Breaker ............................. 5

20 Convenience OutletNo Convenience Outlet ............................................. 0Unpowered Convenience Outlet ............................... APowered Convenience Outlet (3 phase only)3 ........... B

21 Communications Optionsu

No Communications Interface ................................... 0Trane Communications Interface ............................... 1LonTalk® Communications Interface .......................... 2Novar 2024 Controls ................................................. 3Novar 3051 Controls ................................................. 4

22 Refrigeration System OptionStandard Refrigeration System with

Thermal Expansion Value ....................................... 0Dehumidification (Hot Gas Reheat Coil)r .................. B

23 Refrigeration ControlsNo Refrigeration Control ........................................... 0High Pressure Control6u ......................................... 1Frostat5 .................................................................. 2Crankcase Heater .................................................... 3High Pressure Control6u and Frostat5 ..................... 4High Pressure Control6u and Crankcase Heater ....... 5Frostat5 and Crankcase Heater6 ............................. 6High Pressure Control6u, Frostat5 and

Crankcase Heater6 .............................................. 724 Smoke Detector7u

No Smoke Detector .................................................. 0Return Air Smoke Detector89 .................................. ASupply Air Smoke Detector ....................................... BSupply and Return Air Smoke Detectors89 ............... C

25 Monitoring Controlsu

No Monitoring Control0 ............................................ 0Clogged Filter Switch0 ............................................. 1Fan Failure Switch0 ................................................. 2Discharge Air Sensing Tube0 ................................... 3Clogged Filter Switch and Fan Fail Switch0 ............... 4Clogged Filter Switch and Discharge

Air Sensing Tube0 ................................................ 5Fan Fail Switch and Discharge Air Sensing Tube0 ..... 6Clogged Filter and Fan Fail Switches

and Discharge Air Sensing Tube0 .......................... 7Novar Return Air Sensorq ........................................ 8

1 Enthalpy control not available factory installed with electro-mechanical controls.2 Economizer with Barometric Relief is for downfllow configured units only. Order

Economizer without Barometric Relief for horizontal configuration. Barometric relief forhorizontal configured units must be ordered as field installed accessory BAYBARM010A.

3 Requires use of Disconnect or Circuit Breaker.4 Standard refrigeration metering device - short orifice.5 Frostat cannot be field installed in electro-mechanical units.6 High Pressure control is standard on 3 phase units with scroll compressors and in

YSC036A.7 Not available with BAYFRST001A High Temperature Stat accessory.8 The return air smoke detector may not fit up or work properly on the Precedent units

when used in conjunction with 3rd party accessories such as bolt on heat wheels,economizers and power exhaust. Do not order the return air smoke detectors whenusing this type of accessory.

Digit Description Order Number

9 Return Air Smoke Detector cannot be ordered with Novar Controls.0 These options are standard when ordering Novar Controls.q This option is used when ordering Novar Controls.w Includes gas piping and shutoff (field assembly required).e The manual outside air damper will ship factory supplied within the unit, but must be field

installed.r Requires Selection of 2" Pleated Filters (Option B or C) for Digit 16.t Through the base electric required when ordering disconnect/circuit breaker options.y Phase Monitor is standard on T/Y/WSC060A3,4,W models. All other models Phase

Monitor is an option.u Not available with electro-mechanical controls.

Precedent™ Packaged Gas/ElectricConvertible 3-5 Tons 13 SEER R-22(Model Digit Numbers)

Page 241: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PG-41 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Precedent™ Packaged Gas/ElectricConvertible 3-5 Tons 13 SEER R-22

Table PG-41-A — AccessoriesModel Number Description Used WithBAYABRD001C5 ................... ReliaTel™ Options Module ..................................................... See Note8

BAYASCT0010w .................... Anti-Short-Cycle Timer ........................................................... YHC033-063A_EBAYBARM010A7 ................... Barometric Relief .................................................................... YHC033-063ABAYCCHT010B...................... Crankcase Heater ................................................................... YHC033-063A3BAYCCHT011B...................... Crankcase Heater ................................................................... YHC033-063A4,AWBAYCO2K001B5e ................ CO2 Sensor Kit, Wall Mounted ................................................ YHC033-063A_RBAYCO2K003B5e ................ CO2 Sensor Kit, Duct Mounted ............................................... YHC033-063A_RBAYCURB042A4 ................... Roof Curb ............................................................................... YHC033-063ABAYDFPS003A58 ................. Clogged Filter Switch .............................................................. YHC033-063A_RBAYDFPS004A58 ................. Fan Failure Switch .................................................................. YHC033-063A_RBAYDMPR051A5 .................. 0-50% Motorized Outside Air Damper .................................... YHC033-063ABAYDMPR052A0 .................. 0-50% Motorized Outside Air Damper .................................... YHC033-063A_EBAYDMPR053Br .................. 0-50% Manual Outside Air Damper ........................................ YHC033-063ABAYECON085A5 .................. 0-100% Dry Bulb Economizer without Barometric Relief ....... YHC033-063A_RBAYECON086A0 .................. 0-100% Dry Bulb Economizer without Barometric Relief ....... YHC033-063A_EBAYENTH005A1 ................... Reference Enthalpy Kit ........................................................... BAYECON085ABAYENTH006A1 ................... Comparative Enthalpy Kit ....................................................... BAYECON085ABAYENTH001A ...................... Enthalpy Control (Solid State .................................................. BAYECON086ABAYFRST001A56 ................. High Temperature Stat ............................................................ YHC033,063A_RBAYGARD036B ..................... Condenser Coil Hail Guard ..................................................... YHC033-043A**L,MBAYGARD037B ..................... Condenser Coil Hail Guard ..................................................... YHC033-043A**H,YHC063A**L,M,HBAYHAKT010B ...................... High Altitude Kit ...................................................................... YHC033-063ABAYHSMT073A ..................... .45 HP Oversized motor kit ..................................................... YHC033A3BAYHSMT074A ..................... .45 HP Oversized motor kit ..................................................... YHC033A4BAYHSMT075A ..................... .45 HP Oversized motor kit ..................................................... YHC033AWBAYHSMT076A ..................... .75 HP Oversized motor kit ..................................................... YHC043A3BAYHSMT077A ..................... .75 HP Oversized motor kit ..................................................... YHC043A4BAYHSMT078A ..................... .75 HP Oversized motor kit ..................................................... YHC043AWBAYHSMT079A ..................... 1.2 HP Oversized motor kit ..................................................... YHC063A3BAYHSMT080A ..................... 1.2 HP Oversized motor kit ..................................................... YHC063A4BAYHSMT081A ..................... 1.2 HP Oversized motor kit ..................................................... YHC063AWBAYICSI003A5q ................... Trane Communications Interface (TCI) ................................... YHC033-063A_RBAYLOAM020B28 ................ Evaporator Defrost Control (Frostat) ....................................... YHC033-063A_RBAYLPKT028B ....................... LP Conversion Kit ................................................................... YHC033-063ABAYLTCI002B5 ...................... LonTalk® Communications Interface (LCI) .............................. YHC033-063A_RBAYQACB009A49 ................ Quick Adapt Curb ................................................................... YHC033-063ABAYQACB010A49 ................ Quick Adapt Curb ................................................................... YHC033-063ABAYSENS016A5 ................... Temperature Sensor ............................................................... YHC033-063A_RBAYSERV001A5 ................... Selective Resistance Service Tester ...................................... YHC033-063A_RBAYSTAT0235 ....................... Remote Potentiometer ............................................................ BAYECON085ABAYTUBE004A358 .............. Discharge Air Sensing Kit ....................................................... YHC033-063A_RBAYTUBE006A358 .............. Discharge Air Sensing Kit ....................................................... YHC033-063A_RBAYVNOR001B58e ............. Ventilation Override Kit ........................................................... YHC033-063A_R

1 Kits contain all necessary parts to achieve desired levelof enthalpy control.

2 For use with ReliaTel™ microprocessor controlled unitsonly. Must be factory installed for Electromechanicalcontrolled units.

3 Used for true discharge air sensing in both heating andcooling. Required for supply air tempering.

4 Lynn Haven Manufacturing has a No-Return policy forthis roof curb.

5 For use with ReliaTel™ controlled units only.6 Cannot be used in conjunction with factory installed

Smoke Detector option.7 Installs in ductwork for horizontal configuration. For

downflow configuration, it installs in the unit's horizontalreturn duct. See Installer's Guide for more information.

8 BAYABRD001C is required when ordering field installedaccessories Clogged Filter Switch (BAYDFPS003A),Fan Fail Switch (BAYDFPS004A),Discharge Air SensingKit (BAYTUBE004A or BAYTUBE005A) or EvaporatorDefrost Control (Frostat) (BAYLOAM020B) VentilationOverride Kit (BAYVNOR001B) unless the followingoptions are factory installed: Frostat, Smoke Detector,Clogged Filter Switch, Fan Failure Switch, Discharge AirSensing Kit. These factory installed options includethe ReliaTel™ Options Module.

9 BAYQACB009A adapts Voyager BAYCURB021B toaccept Precedent 3 -5 ton unit. BAYQACB010A adaptsVoyager BAYCURB022B to accept Precedent 3-5 tonunit. BAYQACB012A adapts Voyager BAYCURB025B toaccept Precedent 6-10 ton unit. BAYQACB013A adaptsVoyager BAYCURB026B to accept Precedent 6-10 tonunit.BAYQACB011A adapts Voyager BAYCURB022B toaccept Precedent 6-10 ton unit.

0 Electromechanical controlled units onlyq Interface allows 3-10 ton units with ReliaTel™ Controls

to communicates with Tracer 100, Tracker, VariTrac II,and is the preferred method of communication to TracerSummit.

w Activated on Power on.e Field installed accessory. Requires an economizer.r The manual outside air damper will ship factory supplied

within the unit, but must be field installed.

Page 242: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PG-42Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Table PG-42-A — Zone Sensors for ReliaTel™ Controlled UnitsModelNumber Description Used with

BAYSENS006B ...... Single Setpoint Manual Changeover .................................... YHC033-063A_RBAYSENS008B ...... Dual Setpoint Manual or Auto Changeover .......................... YHC033-063A_RBAYSENS010B ...... Dual Setpoint Man. or Auto Change-over with System ........ YHC033-063A_R

Function LightsBAYSENS019C2 ... Programmable Night Setback w/System Function Lights ..... YHC033-063A_RBAYSENS013C1 ... Room Sensor w/ Override and Cancel Buttons .................... YHC033-063A_RBAYSENS014C1 ... Room Sensor w/ Temp. Adjustment with Override and ........ YHC033-063A_R

Cancel ButtonsBAYSENS017B ...... Remote Room Sensor .......................................................... BAYSENS006B,008B,010B,019CBAYSENS032A6 ... Dual Thermistor Remote Zone Sensor ................................. YHC033-063A_RBAYSENS035A6 ... Digital Display Zone Sensor ................................................. YHC033-063A_RBAYSENS036A5 ... Wall-Mounted Humidity Zone Sensor ................................... YHC033-063A3,4,WRBAYSENS037A5 ... Duct-Mounted Humidity Zone Sensor ................................... YHC033-063A3,4,WRBAYMTPL003B ...... Retrofit Wall Cover Plate Kit 7.25" x 6.0" .............................. BAYSENS019CBAYMTPL004B ...... Retrofit Wall Cover Plate Kit 4.75" x 4.75" ............................ BAYSENS006B,007B,010B,

013,014C,017B

Precedent™ Packaged Gas/ElectricConvertible 3-5 Tons 13 SEER R-22

Table PG-42-B — ThermostatsModelNumber Description Used with

BAY28X1903 ............ Locking Thermostat Cover .................................................... Room ThermostatsBAYSTAT040B2 ..... Programmable Thermostat ................................................... YHC033-063ATCONT200AN11AA Electronic, 1 Htg/1 CLG (non-prog) ...................................... YHC033-063ABAYBASE008A ....... Subbase 1-Stage Heating/Cooling ........................................ BAYSTAT040BBAYBASE006A ....... Subbase 2-Stage Heating/Cooling ........................................ BAYSTAT040BBAYSENS033A ....... Remote Wall Sensor ............................................................. BAYSTAT040BBAYSENS034A ....... Remote Duct Sensor ............................................................ BAYSTAT040BBAYSTAT008 ........... Manual 1-Stage Heating/Cooling .......................................... YHC033-063ABAYSTAT010 .......... Auto 2-Stage Heating/Cooling .............................................. YHC033-063A

1 Used with Integrated ComfortTM Systems, any unit type. These sensors do not work with TCM. Consult BASD Marketing for them.2 Requires use of BAYBASE006A or BAYBASE008A.3 Do not use with Programmable Thermostats.4 Use only with electromechanical unit controls.5 For use with Dehumidification (Hot Gas Reheat) Coil Option.6 For use with ReliaTel™ Controls only.* Either standard or high efficiency models.

For additional Controls Information:See ReliaTel™ and Micro Control features on PC-35 and PC-36.

Page 243: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PG-43 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Voyager™ PackagedGas/Electric with ReliaTel™Controls 12½ through 15 Tons

• “Quick-Access” doors and single sideaccess make servicing much faster forlower maintenance costs

• Quick-adjust idler arm pulley. Adjust belttension, change belts, adjust airflowquickly

• High efficiency gas heat with hot surfaceignition for low heating energy costs, lowmaintenance and high reliability

• IAQ sloped condensate drain pans• 5-year limited compressor warranty

(12½-15 tons)• 5-year limited heat exchanger warranty

(12½-15 tons)• 1 year limited parts warranty

YCD — Downflow

• EER up to 11.5• Trane built scroll compressors• Scroll compressors on all models• ReliaTel™ control features are listed on

page PC-35• Built-in anti-short cycle timer, time delay

relay and minimum on time controls• Low Ambient to 0°F standard• High efficiency drum and tube heat

exchanger• Color coded and numbered wiring• Two inch filters on both YCH and YCD to

clean air and keep coil maintenance low• Simple U-shaped airflow pattern results in

very low airside energy requirement

Table PG-43-A — Downflow — Micro Control UnitCooling Heating Output Shipping Max Fuse Size

Unit Power Supply Performance Capacity Capacity Dimensions (in.) Weight or1 1 1 1 1 Max DownflowTons Model No. Volts/Phase/Hz EER (3Ø) (Btuh) (Btuh) H x W x L (Ibs.) MCA* Circuit Breaker* Roofcurb

121/2 YCD150D3L0B 208-230/3/60 9.6 150,000 122,000 501/8 x 715/16 x 1075/16 1826 63 80 BAYCURB026B121/2 YCD150D4L0B 460/3/60 9.6 150,000 122,000 501/8 x 715/16 x 1075/16 1826 33 40 BAYCURB026B121/2 YCD150DWL0B 575/3/60 9.6 150,000 122,000 501/8 x 715/16 x 1075/16 1826 26 30 BAYCURB026B121/2 YCD150D3H0B 208-230/3/60 9.6 150,000 203,000 501/8 x 715/16 x 1075/16 1826 63 80 BAYCURB026B121/2 YCD150D4H0B 460/3/60 9.6 150,000 203,000 501/8 x 715/16 x 1075/16 1826 33 40 BAYCURB026B121/2 YCD150DWH0B 575/3/60 9.6 150,000 203,000 501/8 x 715/16 x 1075/16 1826 26 30 BAYCURB026B121/2 YCD151C3L0B 208-230/3/60 11.3 154,000 122,000 501/8 x 715/16 x 1075/16 1915 64 80 BAYCURB026B121/2 YCD151C4L0B 460/3/60 11.3 154,000 122,000 501/8 x 715/16 x 1075/16 1915 31 40 BAYCURB026B121/2 YCD151CWL0B 575/3/60 11.3 154,000 122,000 501/8 x 715/16 x 1075/16 1915 25 30 BAYCURB026B121/2 YCD151C3H0B 208-230/3/60 11.3 154,000 203,000 501/8 x 715/16 x 1075/16 1915 64 80 BAYCURB026B121/2 YCD151C4H0B 460/3/60 11.3 154,000 203,000 501/8 x 715/16 x 1075/16 1915 31 40 BAYCURB026B121/2 YCD151CWH0B 575/3/60 11.3 154,000 203,000 501/8 x 715/16 x 1075/16 1915 25 30 BAYCURB026B15 YCD180B3L0H 208-230/3/60 9.7 182,000 203,000 501/8 x 715/16 x 1075/16 2033 78 90 BAYCURB026B15 YCD180B4L0H 460/3/60 9.7 182,000 203,000 501/8 x 715/16 x 1075/16 2033 39 50 BAYCURB026B15 YCD180BWL0H 575/3/60 9.7 182,000 203,000 501/8 x 715/16 x 1075/16 2033 31 40 BAYCURB026B15 YCD180B3H0H 208-230/3/60 9.7 182,000 284,000 501/8 x 715/16 x 1075/16 2033 78 90 BAYCURB026B15 YCD180BWH0H 575/3/60 9.7 182,000 284,000 501/8 x 715/16 x 1075/16 2033 31 40 BAYCURB026B15 YCD180B4H0H 460/3/60 9.7 182,000 284,000 501/8 x 715/16 x 1075/16 2033 39 50 BAYCURB026B15 YCD181C3L0C 208-230/3/60 11.5 189,000 203,000 54 x 855/16 x 1225/16 2464 74 90 BAYCURB027B15 YCD181C4L0C 460/3/60 11.5 189,000 203,000 54 x 855/16 x 1225/16 2464 36 50 BAYCURB027B15 YCD181CWL0C 575/3/60 11.5 189,000 203,000 54 x 855/16 x 1225/16 2464 29 40 BAYCURB027B15 YCD181C3H0C 208-230/3/60 11.5 189,000 284,000 54 x 855/16 x 1225/16 2464 74 90 BAYCURB027B15 YCD181C4H0C 460/3/60 11.5 189,000 284,000 54 x 855/16 x 1225/16 2464 36 50 BAYCURB027B15 YCD181CWH0C 575/3/60 11.5 189,000 284,000 54 x 855/16 x 1225/16 2464 29 40 BAYCURB027B

Unit Supply Return Curb Size Roof OpeningModel No. Downflow W x L2323232323 Downflow W x L2323232323 H x W x L2424242424 W x L2323232323

YC❋150,151, 180 289/16 x 551/2 207/8 x 63 141/16 x 6615/16 x 1021/4 621/2 x 731/2YC❋181 289/16 x 691/2 221/4 x 77 141/16 x 8015/16 x 1171/8 761/2 x 81

Note: L = Low Heat H = High Heat in ninth digit1 HACR Type Circuit Breaker per NEC.2 Dimensions are in inches. See Outline Dimensions.3 Interior Dimension.4 Measurement Includes Curb Flange.* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.

Page 244: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PG-44Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Voyager™ PackagedGas/Electric with ReliaTel™Controls 17½ through 25 Tons

YCD — Downflow

• Built-in anti-short cycle timer, time delay relayand minimum on time controls

• Low Ambient to 0°F standard• High efficiency drum and tube heat exchanger• Color coded and numbered wiring• Two inch filters on both YCH and YCD to clean

air and keep coil maintenance low• Simple U-shaped airflow pattern results in very

low airside energy requirement• “Quick-Access” doors and single side access

make servicing much faster for lowermaintenance costs

• Quick-adjust idler arm pulley. Adjust belttension, change belts, adjust airflow quickly

Table PG-44-A — Downflow — Micro Control UnitCooling Heating Output Shipping Max Fuse Size

Unit Power Supply Performance Capacity Capacity Dimensions (in.) Weight or1 1 1 1 1 Max DownflowTons Model No. Volts/Phase/Hz EER (3Ø) (Btuh) (Btuh) H x W x L (Ibs.) MCA* Circuit Breaker* Roofcurb

171/2 YCD210C3L0E 208-230/3/60 9.6 210,000 203,000 501/8 x 715/16 x 1075/16 2189 88 100 BAYCURB026B171/2 YCD210C4L0E 460/3/60 9.6 210,000 203,000 501/8 x 715/16 x 1075/16 2189 44 50 BAYCURB026B171/2 YCD210CWL0E 575/3/60 9.6 210,000 203,000 501/8 x 715/16 x 1075/16 2189 35 45 BAYCURB026B171/2 YCD210C3H0E 208-230/3/60 9.6 210,000 284,000 501/8 x 715/16 x 1075/16 2189 88 100 BAYCURB026B171/2 YCD210C4H0E 460/3/60 9.6 210,000 284,000 501/8 x 715/16 x 1075/16 2189 44 50 BAYCURB026B171/2 YCD210CWH0E 575/3/60 9.6 210,000 284,000 501/8 x 715/16 x 1075/16 2189 35 45 BAYCURB026B171/2 YCD211C3L0C 208-230/3/60 11.0 220,000 203,000 54 x 855/16 x 1225/16 2547 91 110 BAYCURB027B171/2 YCD211C4L0C 460/3/60 11.0 220,000 203,000 54 x 855/16 x 1225/16 2547 44 60 BAYCURB027B171/2 YCD211CWL0C 575/3/60 11.0 220,000 203,000 54 x 855/16 x 1225/16 2547 35 45 BAYCURB027B171/2 YCD211C3H0C 208-230/3/60 11.0 220,000 284,000 54 x 855/16 x 1225/16 2547 91 110 BAYCURB027B171/2 YCD211C4H0C 460/3/60 11.0 220,000 284,000 54 x 855/16 x 1225/16 2547 44 60 BAYCURB027B171/2 YCD211CWH0C 575/3/60 11.0 220,000 284,000 54 x 855/16 x 1225/16 2547 35 45 BAYCURB027B20 YCD240B3L0J 208-230/3/60 9.5 242,000 203,000 54 x 855/16 x 1225/16 2547 100 125 BAYCURB027B20 YCD240B4L0J 460/3/60 9.5 242,000 203,000 54 x 855/16 x 1225/16 2547 50 60 BAYCURB027B20 YCD240BWL0J 575/3/60 9.5 242,000 203,000 54 x 855/16 x 1225/16 2547 40 45 BAYCURB027B20 YCD240B3H0J 208-230/3/60 9.5 242,000 324,000 54 x 855/16 x 1225/16 2547 100 125 BAYCURB027B20 YCD240B4H0J 460/3/60 9.5 242,000 324,000 54 x 855/16 x 1225/16 2547 50 60 BAYCURB027B20 YCD240BWH0J 575/3/60 9.5 242,000 324,000 54 x 855/16 x 1225/16 2547 40 45 BAYCURB027B20 YCD241C3L0C 208-230/3/60 10.6 268,000 203,000 54 x 855/16 x 1225/16 2645 99 125 BAYCURB027B20 YCD241C4L0C 460/3/60 10.6 268,000 203,000 54 x 855/16 x 1225/16 2645 50 60 BAYCURB027B20 YCD241CWL0C 575/3/60 10.6 268,000 203,000 54 x 855/16 x 1225/16 2645 40 50 BAYCURB027B20 YCD241C3H0C 208-230/3/60 10.6 268,000 324,000 54 x 855/16 x 1225/16 2645 99 125 BAYCURB027B20 YCD241C4H0C 460/3/60 10.6 268,000 324,000 54 x 855/16 x 1225/16 2645 50 60 BAYCURB027B20 YCD241CWH0C 575/3/60 10.6 268,000 324,000 54 x 855/16 x 1225/16 2645 40 50 BAYCURB027B25 YCD300B3L0H 208-230/3/60 9.7 290,000 203,000 54 x 855/16 x 1225/16 2541 118 150 BAYCURB027B25 YCD300B4L0H 460/3/60 9.7 290,000 203,000 54 x 855/16 x 1225/16 2541 58 70 BAYCURB027B25 YCD300BWL0H 575/3/60 9.7 290,000 203,000 54 x 855/16 x 1225/16 2541 46 50 BAYCURB027B25 YCD300B3H0H 208-230/3/60 9.7 290,000 324,000 54 x 855/16 x 1225/16 2541 118 150 BAYCURB027B25 YCD300B4H0H 460/3/60 9.7 290,000 324,000 54 x 855/16 x 1225/16 2541 58 70 BAYCURB027B25 YCD300BWH0H 575/3/60 9.7 290,000 324,000 54 x 855/16 x 1225/16 2541 46 50 BAYCURB027B25 YCD301C3L0C 208-230/3/60 10.4 300,000 203,000 54 x 855/16 x 1225/16 2650 120 150 BAYCURB027B25 YCD301C4L0C 460/3/60 10.4 300,000 203,000 54 x 855/16 x 1225/16 2650 58 70 BAYCURB027B25 YCD301CWL0C 575/3/60 10.4 300,000 203,000 54 x 855/16 x 1225/16 2650 47 60 BAYCURB027B25 YCD301C3H0C 208-230/3/60 10.4 300,000 324,000 54 x 855/16 x 1225/16 2650 120 150 BAYCURB027B25 YCD301C4H0C 460/3/60 10.4 300,000 324,000 54 x 855/16 x 1225/16 2650 58 70 BAYCURB027B25 YCD301CWH0C 575/3/60 10.4 300,000 324,000 54 x 855/16 x 1225/16 2650 47 60 BAYCURB027B

Unit Supply Return Curb Size Roof OpeningModel No. Downflow W x L2323232323 Downflow W x L2323232323 H x W x L2424242424 W x L2323232323

YC❋210 289/16 x 551/2 207/8 x 63 141/16 x 6615/16 x 1021/4 621/2 x 731/2YC❋211, 240, 241, 300 289/16 x 691/2 221/4 x 77 141/16 x 8015/16 x 1171/8 761/2 x 81

Note: L = Low Heat H = High Heat in ninth digit1 HACR Type Circuit Breaker per NEC.2 Dimensions are in inches. See Outline Dimensions.3 Interior Dimension.4 Measurement Includes Curb Flange.* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.

• EER up to 11.5• Scroll compressors on all units• ReliaTel™ control features are listed on page

PC-35

• High efficiency gas heat with hot surfaceignition for low heating energy costs, lowmaintenance and high reliability

• IAQ sloped condensate drain pans• 5-year limited compressor warranty

(17½ tons)• 1-year limited compressor warranty

(20 and 25 tons)• 5-year limited heat exchanger warranty

(17½ tons)• 1-year limited heat exchanger warranty (20

and 25 tons)• 1 year limited parts warranty

Page 245: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PG-45 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

YCH — Horizontal

lower maintenance costs• Quick-adjust idler arm pulley. Adjust

belt tension, change belts, adjustairflow quickly

• High efficiency gas heat with hot surfaceignition for low heatingenergy costs, low maintenanceand high reliability

• IAQ sloped condensate drain pans• 5-year limited compressor warranty

(12½-15 tons)• 5-year limited heat exchanger warranty

(12½-15 tons)• 1 year limited parts warranty

• EER up to 11.5• Scroll compressors on all units• ReliaTel™ control features are listed on

page PC-35• Built-in anti-short cycle timer, time delay

relay and minimum on time controls• Low Ambient to 0°F standard• High efficiency drum and tube heat

exchanger• Color coded and numbered wiring• Two inch filters on both YCH and YCD to

clean air and keep coil maintenance low• Simple U-shaped airflow pattern results in

very low airside energy requirement• “Quick-Access” doors and single side

access make servicing much faster for

Voyager™ PackagedGas/Electric with ReliaTel™Controls 12½ through 15 Tons

Table PG-45-A — Horizontal — Micro Control UnitShipping Max Fuse Size

Unit Power Supply Performance Cooling Heating Output Dimensions (in.) Weight or1 1 1 1 1 MaxTons Model No. Volts/Phase/Hz EER (3Ø) Capacity (Btuh) Capacity (Btuh) H x W x L (Ibs.) MCA* Circuit Breaker*

121/2 YCH150D3L0B 208-230/3/60 9.6 150,000 122,000 501/8 x 715/16 x 1075/16 1826 63 80121/2 YCH150D4L0B 460/3/60 9.6 150,000 122,000 501/8 x 715/16 x 1075/16 1826 33 40121/2 YCH150DWL0B 575/3/60 9.6 150,000 122,000 501/8 x 715/16 x 1075/16 1826 26 30121/2 YCH150D3H0B 208-230/3/60 9.6 150,000 203,000 501/8 x 715/16 x 1075/16 1826 63 80121/2 YCH150D4H0B 460/3/60 9.6 150,000 203,000 501/8 x 715/16 x 1075/16 1826 33 40121/2 YCH150DWH0B 575/3/60 9.6 150,000 203,000 501/8 x 715/16 x 1075/16 1826 26 30121/2 YCH151C3L0B 208-230/3/60 11.3 154,000 122,000 501/8 x 715/16 x 1075/16 1915 64 80121/2 YCH151C4L0B 460/3/60 11.3 154,000 122,000 501/8 x 715/16 x 1075/16 1915 31 40121/2 YCH151DWL0B 575/3/60 11.3 154,000 122,000 501/8 x 715/16 x 1075/16 1915 25 30121/2 YCH151C3H0B 208-230/3/60 11.3 154,000 203,000 501/8 x 715/16 x 1075/16 1915 64 80121/2 YCH151C4H0B 460/3/60 11.3 154,000 203,000 501/8 x 715/16 x 1075/16 1915 31 40121/2 YCH151DWH0B 575/3/60 11.3 154,000 203,000 501/8 x 715/16 x 1075/16 1915 25 3015 YCH180B3L0H 208-230/3/60 9.7 182,000 203,000 501/8 x 715/16 x 1075/16 2033 78 9015 YCH180B4L0H 460/3/60 9.7 182,000 203,000 501/8 x 715/16 x 1075/16 2033 39 5015 YCH180BWL0H 575/3/60 9.7 182,000 203,000 501/8 x 715/16 x 1075/16 2033 31 4015 YCH180B3H0H 208-230/3/60 9.7 182,000 284,000 501/8 x 715/16 x 1075/16 2033 78 9015 YCH180B4H0H 460/3/60 9.7 182,000 284,000 501/8 x 715/16 x 1075/16 2033 39 5015 YCH180BWH0H 575/3/60 9.7 182,000 284,000 501/8 x 715/16 x 1075/16 2033 31 4015 YCH181C3L0C 208-230/3/60 11.5 189,000 203,000 54 x 855/16 x 1225/16 2464 74 9015 YCH181C4L0C 460/3/60 11.5 189,000 203,000 54 x 855/16 x 1225/16 2464 36 5015 YCH181CWL0C 575/3/60 11.5 189,000 203,000 54 x 855/16 x 1225/16 2464 29 4015 YCH181C3H0C 208-230/3/60 11.5 189,000 284,000 54 x 855/16 x 1225/16 2464 74 9015 YCH181C4H0C 460/3/60 11.5 189,000 284,000 54 x 855/16 x 1225/16 2464 36 5015 YCH181CWH0C 575/3/60 11.5 189,000 203,000 54 x 855/16 x 1225/16 2464 29 40Unit Supply ReturnModel No. Horizontal H x W2323232323 Horizontal H x W2323232323

YC❋150C 417/16 x 221/2 417/16 x 173/16

YC❋151, 180 421/2 x 261/2 421/2 x 249/16

YC❋181 467/16 x 261/2 467/16 x 279/16

Note: L = Low Heat H = High Heat in ninth digit1 HACR Type Circuit Breaker per NEC.2 Dimensions are in inches. See Outline Dimensions.3 Interior Dimension.* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.

Page 246: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PG-46Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Voyager™ PackagedGas/Electric with ReliaTel™Controls 17½ through 25 Tons

• Built-in anti-short cycle timer, time delay relayand minimum on time controls

• Low Ambient to 0°F standard• High efficiency drum and tube heat exchanger• Color coded and numbered wiring• Two inch filters on both YCH and YCD to clean

air and keep coil maintenance low• Simple U-shaped airflow pattern results in very

low airside energy requirement• “Quick-Access” doors and single side access

make servicing much faster for lowermaintenance costs

• Quick-adjust idler arm pulley. Adjust belttension, change belts, adjust airflow quickly

YCH — Horizontal• EER up to 11.5• Scroll compressors on all units• ReliaTel™ control features are listed on page

PC-35

Table PG-46-A — Horizontal — Micro Control UnitMax Fuse SizeShipping Max Fuse Size

Unit Power Supply Performance Cooling Heating Output Dimensions (in.) Weight or1 1 1 1 1 MaxTons Model No. Volts/Phase/Hz EER (3Ø) Capacity (Btuh) Capacity (Btuh) H x W x L (Ibs.) MCA* Circuit Breaker*

171/2 YCH210C3L0E 208-230/3/60 9.6 210,000 203,000 501/8 x 715/16 x 1075/16 2189 88 110171/2 YCH210C4L0E 460/3/60 9.6 210,000 203,000 501/8 x 715/16 x 1075/16 2189 44 50171/2 YCH210CWL0E 575/3/60 9.6 210,000 203,000 501/8 x 715/16 x 1075/16 2189 35 45171/2 YCH210C3H0E 208-230/3/60 9.6 210,000 284,000 501/8 x 715/16 x 1075/16 2189 88 110171/2 YCH210C4H0E 460/3/60 9.6 210,000 284,000 501/8 x 715/16 x 1075/16 2189 44 5071/2 YCH210CWH0E 575/3/60 9.6 210,000 284,000 501/8 x 715/16 x 1075/16 2189 35 45171/2 YCH211C3L0C 208-230/3/60 11.0 220,000 203,000 54 x 855/16 x 1225/16 2547 91 110171/2 YCH211C4L0C 460/3/60 11.0 220,000 203,000 54 x 855/16 x 1225/16 2547 44 60171/2 YCH211CWL0C 575/3/60 11.0 220,000 203,000 54 x 855/16 x 1225/16 2547 35 45171/2 YCH211C3H0C 208-230/3/60 11.0 220,000 284,000 54 x 855/16 x 1225/16 2547 91 110171/2 YCH211C4H0C 460/3/60 11.0 220,000 284,000 54 x 855/16 x 1225/16 2547 44 60171/2 YCH211CWH0C 575/3/60 11.0 220,000 284,000 54 x 855/16 x 1225/16 2547 35 4520 YCH240B3L0J 208-230/3/60 9.5 242,000 203,000 54 x 855/16 x 1225/16 2547 100 12520 YCH240B4L0J 460/3/60 9.5 242,000 203,000 54 x 855/16 x 1225/16 2547 50 6020 YCH240BWL0J 575/3/60 9.5 242,000 203,000 54 x 855/16 x 1225/16 2547 40 4520 YCH240B3H0J 208-230/3/60 9.5 242,000 324,000 54 x 855/16 x 1225/16 2547 100 12520 YCH240B4H0J 460/3/60 9.5 242,000 324,000 54 x 855/16 x 1225/16 2547 50 6020 YCH240BWH0J 575/3/60 9.5 242,000 324,000 54 x 855/16 x 1225/16 2547 40 4520 YCH241C3L0C 208-230/3/60 10.6 268,000 203,000 54 x 855/16 x 1225/16 2645 99 12520 YCH241C4L0C 460/3/60 10.6 268,000 203,000 54 x 855/16 x 1225/16 2645 50 6020 YCH241CWL0C 575/3/60 10.6 268,000 203,000 54 x 855/16 x 1225/16 2645 40 5020 YCH241C3H0C 208-230/3/60 10.6 268,000 324,000 54 x 855/16 x 1225/16 2645 99 12520 YCH241C4H0C 460/3/60 10.6 268,000 324,000 54 x 855/16 x 1225/16 2645 50 6020 YCH241CWH0C 575/3/60 10.6 268,000 324,000 54 x 855/16 x 1225/16 2645 40 5025 YCH300B3L0H 208-230/3/60 9.3 290,000 203,000 54 x 855/16 x 1225/16 2541 118 15025 YCH300B4L0H 460/3/60 9.3 290,000 203,000 54 x 855/16 x 1225/16 2541 58 7025 YCH300BWL0H 575/3/60 9.3 290,000 203,000 54 x 855/16 x 1225/16 2541 46 5025 YCH300B3H0H 208-230/3/60 9.3 290,000 324,000 54 x 855/16 x 1225/16 2541 118 15025 YCH300B4H0H 460/3/60 9.3 290,000 324,000 54 x 855/16 x 1225/16 2541 58 7025 YCH300BWH0H 575/3/60 9.3 290,000 324,000 54 x 855/16 x 1225/16 2541 46 5025 YCH301C3L0C 208-230/3/60 10.4 300,000 203,000 54 x 855/16 x 1225/16 2650 120 15025 YCH301C4L0C 460/3/60 10.4 300,000 203,000 54 x 855/16 x 1225/16 2650 58 7025 YCH301CWL0C 575/3/60 10.4 300,000 203,000 54 x 855/16 x 1225/16 2650 47 6025 YCH301C3H0C 208-230/3/60 10.4 300,000 324,000 54 x 855/16 x 1225/16 2650 120 15025 YCH301C4H0C 460/3/60 10.4 300,000 324,000 54 x 855/16 x 1225/16 2650 58 7025 YCH301CWH0C 575/3/60 10.4 300,000 324,000 54 x 855/16 x 1225/16 2650 47 60

Unit Supply ReturnModel No. Horizontal H x W2323232323 Horizontal H x W2323232323

YC❋ 210 421/2 x 261/2 421/2 x 249/16

YC❋211, 240, 241, 300 467/16 x 261/2 467/16 x 279/16

Note: L = Low Heat H = High Heat in ninth digit1 HACR Type Circuit Breaker per NEC.2 Dimensions are in inches. See Outline Dimensions.3 Interior Dimension.* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.

• High efficiency gas heat with hot surfaceignition for low heating energy costs, lowmaintenance and high reliability

• IAQ sloped condensate drain pans• 5-year limited compressor warranty

(17½ tons)• 1-year limited compressor warranty

(20 and 25 tons)• 5-year limited heat exchanger warranty

(17½ tons)• 1-year limited heat exchanger warranty

(20 and 25 tons)• 1 year limited parts warranty

Page 247: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PG-47 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Voyager™ PackagedGas/Electric with ReliaTel™Controls12½ through 25 Tons

Table PG-47-A —Factory Installed Accessories12 For Complete list of all Factory Installed Options, please refer to the FIOPSsection of this book.

Digit Description Order Number Used With

1-9 Main Assembly (see previous page)10 Factory Installed Options

No Options 0 YC*150-301Downflow Economizer3 A YCD150-301Oversized Motor B YC*150-241Downflow Economizer and Oversized Motor3 C YCD150-241Trane Communications Interface (TCI)4 F YC*150-301Downflow Economizer TCI34 G YCD150-301TXV/Face - Split Evaporator H YCD151, 181, 211, 241, 301Oversized Motor and TXV/Face -Split Evaporator J YCD151, 181, 211, 241Downflow Economizer, Oversized Motor and TXV/Face K YCD151, 181, 211, 241Split Evaporator3Downflow Economizer with TXV/Face - Split Evaporator3 L YCD151, 181, 211, 241, 301Reheat Coil5 M YCD151, 181, 241Downflow Economizer with Reheat Coil35 N YCD151, 181, 241Oversized Motor and Reheat Coil5 P YCD151, 181, 241Downflow Economizer, Oversized Motor and R YCD151, 181, 241Reheat Coil 35

11-12 Minor Design and Service Sequence **1 Price includes accessory and factory installation.2 Four (4) week shipping approximately.3 Some field set up required.4 TCI is for use with non-VariTrac systems and VariTrac systems.5 All 10th digit model numbers including reheat coil (M,N,P,R) require additional factory installed options; ReliaTel™ options module (FIYABRD002B), Frostat

(FIYLOAM023A), and 2" pleated filters (FIYPLTD001A, 002A, or 003A refer to FIOPS section for appropriate model number usage). For these or any Factory InstalledOptions not included in 10th digit model number, digits 1-3 must be YFD.

Page 248: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PG-48Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Voyager™ Packaged Gas/Electricwith ReliaTel™ Controls12½ through 25 Tons Accessories

Table PG-48-A — Field Installed Accessories For complete list of of All Factory Installed Options refer to FIOPS section of this book.Model Number Description Used With

BAYABRD002Bq ........ ReliaTel™ Options Module ................................................ YCD/YCH150-301BAYCO2K002Bw ........ CO2 Sensor Wall Mounted ................................................. YC*150-301 w/EconomizerBAYCO2K004Bw ........ CO2 Sensor Duct Mounted ................................................ YC*150-301 w/EconomizerBAYCURB026B67 ..... Downflow Only Roof Curb ................................................. YCD150D, 151C, 180B, 210CBAYCURB027B67 ..... Downflow Only Roof Curb ................................................. YCD181C, 211-301BAYDFPS005A9q ...... Clogged Filter Switch ........................................................ YCD/YCH (12½-25 Tons)BAYDFPS006A9q ...... Fan Failure Switch ............................................................. Economizers/0-50% Motorized Outside Air DampersBAYDMPR029C .......... 0-25% Manual Outside Air Damper ................................... YCD/YCH (12½-25 Tons)BAYDMPR057A .......... 0-50% Motorized Outside Air Damper ............................... YCD/YCH150D, 151C, 180B, 210CBAYDMPR058A .......... 0-50% Motorized Outside Air Damper ............................... YCD/YCH181, 211-301BAYECON089Aq ........ Downflow Economizer with Barometric Relief ................... YCD150D, 151C, 180B, YCD210CBAYECON090Aq ........ Downflow Economizer with Barometric Relief ................... YCD181C, 211, 240B, 241C, 300B, 301CBAYECON091A .......... Horizontal Economizer ...................................................... YCH150D, 151C, 180B, YCH210CBAYECON092A .......... Horizontal Economizer ...................................................... YCH181C, 211-301BAYENTH007A12 .... Reference Enthalpy Kit ...................................................... All BAYECON089A-092ABAYENTH008A123 .. Comparative Enthalpy Kit ................................................. All BAYECON089A-092ABAYFRST003A ........... High Temperature Stat ...................................................... YCD/YCH150DBAYGARD043Bq ........ Tool-less Hail Guard .......................................................... YC*150DBAYGARD044Bq ........ Tool-less Hail Guard .......................................................... YC*151C, 180B, 210CBAYGARD045Aq ........ Tool-less Hail Guard .......................................................... YC*181C, 211C, 240B,241C, 301CBAYGARD047Aq ........ Tool-less Hail Guard .......................................................... YC*300BBAYHSDR002B4 ....... High Static Drive ................................................................ YCD/YCH151CBAYHSDR005B4 ....... High Static Drive ................................................................ YCD/YCH150D,180B, 211C, 240B, 241BBAYHSDR010A ........... High Static Drive ................................................................ YCD/YCH300B, 301CBAYHSDR011A ........... High Static Drive ................................................................ YCD/YCH181CBAYHSMT039B4q .... 5 HP Oversized Motor Kit .................................................. YCD/YCH150D,151C, 180BBAYHSMT040Bq ........ 5 HP Oversized Motor Kit .................................................. YCD/YCH150DWBAYHSMT042A5q .... 7-1/2HP Oversized Motor Kit (575V) ................................. YC*211C, 240B, 241CWBAYHSMT055B4q .... 5HP Oversized Motor Kit ................................................... YCD/YCH181CBAYHSMT059A5q .... 7-1/2HP Oversized Motor Kit (230V) ................................. YCD/YCH210CBAYHSMT060A5q .... 7-1/2HP Oversized Motor Kit (460V) ................................. YCD/YCH210CBAYHSMT061A5q .... 7-1/2HP Oversized Motor Kit (575V) ................................. YC*210CWBAYHSMT072A5q .... 7-1/2HP Oversized Motor Kit (575V) ................................. YC*181CWBAYHSMT098A5q ..... 7-1/2HP Oversized Motor Kit .............................................. YC*211,240,241C3BAYHSMT099A5q ..... 7-1/2HP Oversized Motor Kit .............................................. YC*211,240,241C4BAYICSI004B0e .......... Trane Comunications Interface, Comm 3/4 (TCI) ................... YC*150-301BAYLOAM023A9 ......... Evaporator Defrost Control ................................................... YCD150-301BAYLPKT018A ............ LP Conversion Kit .............................................................. YCD/YCH150D,151-301CBAYLSDR004A5 ....... Low Static Drive ................................................................. YCD/YCH210CBAYLSDR002A5 ....... Low Static Drive ................................................................. YCD/YCH300B, 301CBAYLTCI003B0 ........... LonTalk® Communications Interface (LCI) ......................... YC*150-301BAYPWRX029A .......... Power Exhaust for 230 volt units ....................................... BAYECON062-089A,063-090A,065-091A,066-092A (YCD150D, 151-301C)BAYPWRX030A .......... Power Exhaust for 460 volt units ....................................... BAYECON062-089A,063-090A,065-091A,066-092A (YCD150D, 151-301C)BAYPWRX031A .......... Power Exhaust for use with Downflow Economizer(575V) ........ YCD150DWBAYSENS016A ........... Temperature Sensor .......................................................... YCD/YCH (12½-25 Tons)BAYSERV001A ........... Selective Resistance Service Tester ................................. YCD/YCH (12½-25 Tons)BAYSTAT0237 ........... Remote Potentiometer ....................................................... All BAYECON089-92ABAYTUBE008A9q ...... Discharge Air Sensing Kit .................................................. YCD150D-301BAYTUBE009A9q ...... Discharge Air Sensing Kit .................................................. YCH150-301BAYVNOR002B9 ........ Ventilation Override Kit ...................................................... YCD/YCH150-301 w/Reliatel™ Options Module

Table PG-48-B — Zone SensorsBAYMTPL003B ........... Retrofit Wall Cover Plate Kit (71/4" x 6") ............................................. BAYSENS019CBAYMTPL004B ........... Retrofit Wall Cover Plate Kit (43/4" x 43/4") .......................................... BAYSENS006B, 008B, 010B, 017B, 013C, 014CBAYSENS006B ........... Single Setpoint Manual Changeover ................................................. YC*150-301BAYSENS008B ........... Dual Setpoint Manual or Auto Changeover ....................................... YC*150-301BAYSENS010B ........... Dual Setpoint Man. or Auto Changeover with Sys. Funct. Light ......... YC*150-301BAYSENS013C8 ....... Room Sensor with Override Button ................................................... YC*150-301BAYSENS014C8 ....... Room Sensor with Temperature Adjustment and Override .............. YC*150-301BAYSENS017B ........... Remote Room Sensor ....................................................................... BAYSENS006B, 008B, 010B, 019CBAYSENS019C ........... Programmable Night Setback with System Function Lights .............. YC*150-301BAYSENS032A0 ........ Dual Thermistor Remote Zone Sensor .............................................. YC*150-301BAYSENS035A0 ........ Digital Display Zone Sensor ............................................................... YC*150-300BAYSENS036A ........... Wall-Mounted Humidity Sensor ......................................................... YFD151,181,241 (with Reheat)BAYSENS037A ........... Duct-Mounted Humidity Sensor ......................................................... YFD151,181,241 (with Reheat)

1 Kit contains all necessary parts to achieve desired level of Enthalpy Control.2 Reference Enthalpy senses outside temperature/humidity and inside supply air only.3 Comparative Enthalpy senses outside temperature/humidity and inside supply and

return air.4 High static drive and oversized motors are mutually exclusive, Do Not Combine.5 Low static drive and oversized motors are mutually exclusive, Do Not Combine.6 See Accessory IOM for operational characteristics.7 Clarksville Manufacturing has a no-return policy for this roof curb.

8 Used with Integrated Comfort SystemsTM any unit type. These sensors do not work withTCM. Consult BASD Marketing for them.

9 BAYABRD002 is required when ordering BAYDFPS005A or 006A, BAYTUBE008A or009A and BAYLOAM023A or BAYVNOR002B.

0 Functional only with ReliaTel™ controls.q Field or factory installed option.* Either horizontal or downflow modelsw Field installed accessory. Requires an economizer.e Interface allows a unit with ReliaTel™ Controls to communicate with Tracer 100,

Tracker, VariTrac II, and is the preferred method of communication to Tracer Summit.See ReliaTel™ and Micro Control features on PC-35 and PC-36.

Page 249: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PG-49 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

12 1/2 – 25 Ton Packaged Gas/Electric, Electric/Electric and HeatPump

Voyager™ Packaged Unit Accessories121/2 through 25 Tons

Factory SuppliedAccessoriesUnitYCD/H, TCD/H, WCD/HCoil Guard (3-7 1/2 Ton)(BAYGARD)Economizer (Downflow andHorizontal) (BAYECON)Fresh Air Damper (BAYDMPR)Manual (3-25 Ton) (0-25%)Motorized (5-25 Ton Only) (0-50%)Sensor/Thermostat

Curb (BAYCURB)

Quick Adapt Curb...Field Supplied(8 1/2-25 Ton Only) (BAYCURB)Power Exhaust (BAYPWRX)(6 1/4-25 Ton Only) (BAYPWRX)

A

G

E

D

S

C

QA

PE

Page 250: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

FIOPS-1 Effective 1/1/06

Trane offers a variety of factory installed options (FIOPS) for the light commercial packaged rooftop product line. These optionsare in addition to the standard factory installed options, i.e., downflow economizer and oversized motors.

Black Epoxy Coated Condenser Coil – Black Epoxy coil protection is a fac-tory-applied, thermoset vinyl coating that is bonded to the aluminum fin stockprior to the fin stamping process. The pre-coated coils are an economical optionfor protection in mildly corrosive environments.

Dehumidification Option – The dehumidification (hot gas reheat) option shallbe a factory-installed option that provides increased dehumidification. Theoption shall consist of a hot-gas reheat coil located on the leaving air side of theevaporator coil prepiped and circuited. The option shall be equipped withcrankcase heater(s), low pressure switch(es), Frostat™, and a thermostaticexpansion valve(s) (TXV) as standard.

Differential Pressure Switches – A dedicated differential pressure switch isavailable to achieve active fan failure indication and/or clogged filter indication.These indications will be registered on a zone sensor with status indicationlights. This option is available for all 12½ – 25 ton models.

Electric Heaters – Factory installed and wired electric heatersare available for all 230, 460, and 575 volt 3-phase horizontal and downflow12½ – 25 ton models. If ordering the Through the Base Electrical option with anElectric Heater, the heater must be factory installed.

High Efficiency Motors – Available with efficiency ratings from 86.5 up to 91.0.Check unit specifications for specific motor size per unit model.

Hinged Access Doors – Sheet metal hinges are available factory installed onthe Filter/Evaporator Access Door and the Compressor/Control Access Door ofall 12½ – 25 ton downflow units.

Powered or Unpowered Convenience Outlet – This option is a GFCI, 120volt/15 amp, 2 plug, convenience outlet, either powered or unpowered. Whenthe convenience outlet is powered, a service receptacle disconnect will beavailable. The convenience outlet is powered from the line side of thedisconnect or circuit breaker, and therefore will not be affected by the positionof the disconnect or circuit breaker.

This option is available for all 12½– 25 ton downflow units and can only beordered when the Through the Base Electrical with either the Disconnect Switchor Circuit Breaker option is ordered.

Reference or Comparative Enthalpy – When a factory installed DownflowEconomizer is ordered, an option will be to factory install either Reference orComparative Enthalpy Control.

Supply and Return Air Smoke Detector – With this option installed, if smokeis detected the line will shut down all operation. Reset will be manual at the unit.Smoke detectors are photo cell.

Through the Base Electrical with Circuit Breaker – This optionis a factory installed thermal magnetic, molded case, HACR Circuit Breakerwith provisions for through the base electrical connections. The circuit breakerwill be installed in a water tight enclosure in the unit with access through aswinging door. Factory wiring will be provided from the switch to the unit highvoltage terminal block. The circuit breaker will provide overcurrent protection,be sized per NEC and UL guidelines, and be agency recognized by UL/CSA.

This option is available for all 12½ – 25 ton downflow models. Either a CircuitBreaker or a Disconnect Switch (not both) must be ordered when ordering theThrough the Base Electrical option.

Through the Base Electrical with Disconnect Switch – Factory installed 3-pole, molded case disconnect switch with provisions for through the base electri-cal connections are available. The disconnect switch will be installed in the unit ina water tight enclosure with access through a swinging door. Factory wiring willbe provided from the switch to the unit high voltage terminal block. The switchwill be UL/CSA agency recognized. Note: The disconnect switchwill be sized per NEC and UL guidelines but will not be used in place of unitovercurrent protection.

This option is available for all 230, 460 and 575 volt, 3-phase downflow 12½ – 25ton models. Either a Circuit Breaker or a Disconnect Switch (not both) must beordered when ordering the Through the Base Electrical option.

Through the Base Gas Piping – With this option, provision willbe made in the unit for installing through the base gas piping. The option willhave all piping necessary including a pre-assembled, black steel, manual gasshut-off valve, elbows and union. The manual shut-off valve shall include a 1/8inch NPT pressure tap. This assembly will require minor field labor to install.

This option is available for all 12½ – 25 ton downflow gas/electric units, and canonly be ordered when the Through the Base Electrical Option with Disconnect orCircuit Breaker is ordered.

Thermal Expansion Valve (TXV) and Face Split Evaporator – All units have ashort orifice refrigerant control metering device. For more exact refrigerant flow,when using units in low airflow or high outside air applications, a ThermalExpansion Valve option shall be available. This is available on High EfficiencyGas/Cooling units only.

Discharge Air Sensing Kit – This option provides true discharge air sensing inheating models. This sensor is a status indicator readable through Tracer® orTracker®. The kit is functional only with the ReliaTel™ Module.

Coil Guards – Hail protection quality coil guards shall be either factory or field-installed for condenser coil protection.

High Efficiency Motors – This option is available with efficiency ratings from86.5 up to 91.0. Not available for all models.

Supply and/or Return Air Smoke Detector – With this option installed, if smokeis detected, all unit operation will be shut down. Reset will be manual at the unit.Return Air Smoke Detectors require minimum allowable airflow when used withcertain models. See the Installation, Operation, and Maintenance (IOM) manualfor the models affected and the minimum allowable airflow required. This optionis available on all 12½-25 tons downflow models.

Frostat – This factory or field installed option is to be utilized as a safety device.The Frostat opens when temperatures on the evaporator coil fall below 10°F. Thetemperature will need to rise to 50°F before closing. This option should be utilizedin low airflow or high outside air applications.

Through the Base Utilities Access – An electrical service entrance shall beprovided allowing electrical access for both control and main power connectioninside the curb and through the base of the unit. Option will allow for fieldinstallation of liquid-tight conduit and an external field installed disconnect switch.

Novar Unit Controls – Novar rooftop unit controls will be factor installed andtested. The Novar electronic thermostat module will interface to the unitmicroprocessor and will control the unit to the desired stage of cooling or heating.The Novar electronic thermostat module will monitor the following unitinformation: fan failure status, cooling stage 1-on status, cooling stage 2 onstatus, heating on status, clogged filter status or unit shutdown status, anddischarge air temperature. The Novar electronic thermostat module will have theability to enable the unit mounted economizer.

Novar Return Air Sensor – This option, when used in conjunction with NovarControls, will contain a factory provided wired zone temperature sensor located inthe return air stream.

Two Inch Pleated Filters – Two inch pleated media filters shall be available onall 12½-20 ton models.

Voyager™ Factory Installed OptionsCommercial Packaged Units 12½ through 25 Tons

Before Ordering:Not all factory options are offered for single phase units.Please contact the Clarksville, TN Support Team for latest updates offactory installed options and ordering instructions.Call (931) 645-6471 and ask to be connected to the Light CommercialProduct Support Team.

* Some FIOPs available only for certaintonnages, unit functions, or efficiencies.

Page 251: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

FIOPS-2Effective 1/1/06

Table FIOPS-2-A — AccessoriesModelNumber Description Used WithBlack Epoxy Coated Condenser CoilFIYCOIL205A Black Epoxy Coated Condenser Coil T/Y/WC*150FIYCOIL206A Black Epoxy Coated Condenser Coil T/YC*151,180,210FIYCOIL207A Black Epoxy Coated Condenser Coil WC*180FIYCOIL209A Black Epoxy Coated Condenser Coil T/YC*181,211,240,241,301, WC*240FIYCOIL210A Black Epoxy Coated Condenser Coil T/YC*300Circuit BreakerMust be used with Through-the-Base Electrical option (downflow only).FIYUCB3175A Unit Mounted Circuit Breaker Consult Matrix SheetsFIYUCB3200A Unit Mounted Circuit Breaker Consult Matrix SheetsFIYUCB3225A Unit Mounted Circuit Breaker Consult Matrix SheetsFIYUCB3250A Unit Mounted Circuit Breaker Consult Matrix SheetsFIYUCB4015A Unit Mounted Circuit Breaker Consult Matrix SheetsFIYUCB4020A Unit Mounted Circuit Breaker Consult Matrix SheetsFIYUCB4025A Unit Mounted Circuit Breaker Consult Matrix SheetsFIYUCB4030A Unit Mounted Circuit Breaker Consult Matrix SheetsFIYUCB4035A Unit Mounted Circuit Breaker Consult Matrix SheetsFIYUCB4040A Unit Mounted Circuit Breaker Consult Matrix SheetsFIYUCB4045A Unit Mounted Circuit Breaker Consult Matrix SheetsFIYUCB4050A Unit Mounted Circuit Breaker Consult Matrix SheetsFIYUCB4060A Unit Mounted Circuit Breaker Consult Matrix SheetsFIYUCB4070A Unit Mounted Circuit Breaker Consult Matrix SheetsFIYUCB4080A Unit Mounted Circuit Breaker Consult Matrix SheetsFIYUCB4090A Unit Mounted Circuit Breaker Consult Matrix SheetsFIYUCB4100A Unit Mounted Circuit Breaker Consult Matrix SheetsFIYUCB4110A Unit Mounted Circuit Breaker Consult Matrix SheetsFIYUCB4125A Unit Mounted Circuit Breaker Consult Matrix SheetsFIYUCB4150A Unit Mounted Circuit Breaker Consult Matrix SheetsFIYUCB6110A Unit Mounted Circuit Breaker Consult Matrix SheetsFIYUCB6125A Unit Mounted Circuit Breaker Consult Matrix SheetsConvenience OutletMust be ordered with Through-the-Base Electrical option and either Unit Mounted Disconnect or Circuit Breaker (downflow only).FIYCOPO201A Powered, 120V Convenience Outlet, 230V TC/YCD150-301*3, WCD150-240*3FIYCOPO202A Powered, 120V Convenience Outlet, 230V TC/YCD150-301*4, WCD150-240*4FIYCOPO205A Powered, 120V Convenience Outlet, 230V TC/YCD150-301*W, WCD150-240*WFIYCOUP201A Unpowered, 115V Convenience Outlet TC/YCD150-301, WCD150-240Discharge Air Sensing KitUsed for true discharge air sensing in heating models. Functional only with ReliaTelTM Options Module (FIYABRD002B).FIYTUBE008A Discharge Air Sensing Kit (All Voltages) TC/YCD150-301*, WCD150-240FIYTUBE009A Discharge Air Sensing Kit (All Voltages) TC/YCH150-301*, WCH150-240Disconnect SwitchMust be used with Through-the-Base Electrical option (downflow only). Cannot be fused.FIYUDC3250A Unit Mounted Disconnect Switch Consult Matrix SheetsFIYUDC4100A Unit Mounted Disconnect Switch Consult Matrix SheetsFIYUDC4150A Unit Mounted Disconnect Switch Consult Matrix SheetsFIYUDC6100A Unit Mounted Disconnect Switch Consult Matrix SheetsEconomizer Actuator Logic ModuleFIYLGCM001A is required when ordering the following Factory Installed Options (FIOPs). Reference Enthalpy (FIYENTH007A), ComparativeEnthalpy (FIYENTH008A), Novar Controls (FIYCNTL013A, 015A,016A, 017A,018A, 019A).FIYLGCM001A Economizer Actuator Logic Module All Voyager units with economizers and the

above mentioned FIOPs. (FIOP #s)

Downflow/Horizontal Packaged Cooling,Packaged Gas/Electric/Packaged HeatPump Factory Installed Options (FIOPS)

Page 252: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

FIOPS-3 Effective 1/1/06

Table FIOPS-3-A — AccessoriesModelNumber Description Used WithElectric Heat - CoolingMust be factory installed when using with Through-the-Base Electrical option.FIDHTRA309B Factory Installed 9 KW Electric Heat See Unit Price SheetsFIDHTRA318B Factory Installed 18 KW Electric Heat See Unit Price SheetsFIDHTRA327B Factory Installed 27 KW Electric Heat See Unit Price SheetsFIDHTRA336B Factory Installed 36 KW Electric Heat See Unit Price SheetsFIDHTRD318A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIDHTRD336A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIDHTRD354A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIDHTRF318A Factory Installed 18 KW Electric Heat See Unit Price SheetFIDHTRK336A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIDHTRK354A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIDHTRL336A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIDHTRL354A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIDHTRK372A Factory Installed 72 KW Electric Heat See Unit Price SheetsFIDHTRJ318A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIDHTRJ336A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIDHTRA409B Factory Installed 9 KW Electric Heat See Unit Price SheetsFIDHTRA418B Factory Installed 18 KW Electric Heat See Unit Price SheetsFIDHTRA427B Factory Installed 27 KW Electric Heat See Unit Price SheetsFIDHTRA436B Factory Installed 36 KW Electric Heat See Unit Price SheetsFIDHTRC418A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIDHTRD436A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIDHTRD454A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIDHTRL418A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIDHTRK436A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIDHTRK454A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIDHTRL436A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIDHTRL454A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIDHTRK472A Factory Installed 72 KW Electric Heat See Unit Price SheetsFIDHTRJ418A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIDHTRJ436A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIDHTRAW18B Factory Installed 18 KW Electric Heat See Unit Price SheetsFIDHTRAW27B Factory Installed 27 KW Electric Heat See Unit Price SheetsFIDHTRCW18A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIDHTRCW36A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIDHTRCW54A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIDHTRKW18A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIDHTRKW54A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIDHTRMW36A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIDHTRLW54A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIDHTRKW72A Factory Installed 72 KW Electric Heat See Unit Price SheetsFIDHTRJW18A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIDHTRJW36A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRA309B Factory Installed 9 KW Electric Heat See Unit Price SheetsFIHHTRA318B Factory Installed 18 KW Electric Heat See Unit Price SheetsFIHHTRA327B Factory Installed 27 KW Electric Heat See Unit Price SheetsFIHHTRA336B Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRD318A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIHHTRD336A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRD354A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIHHTRM318A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIHHTRM336A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRM354A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIHHTRN336A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRN354A Factory Installed 54 KW Electric Heat See Unit Price Sheets

Downflow/Horizontal PackagedCooling,Packaged Gas/Electric/Packaged HeatPump Factory Installed Options (FIOPS)

Page 253: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

FIOPS-4Effective 1/1/06

Downflow/Horizontal Packaged Cooling,Packaged Gas/Electric/Packaged HeatPump Factory Installed Options (FIOPS)

Table FIOPS-4-A — AccessoriesModelNumber Description Used WithElectric Heat - Cooling (Contd.)FIHHTRN372A Factory Installed 72 KW Electric Heat See Unit Price SheetsFIHHTRJ318A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIHHTRJ336A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRA409B Factory Installed 9 KW Electric Heat See Unit Price SheetsFIHHTRA418B Factory Installed 18 KW Electric Heat See Unit Price SheetsFIHHTRA427B Factory Installed 27 KW Electric Heat See Unit Price SheetsFIHHTRA436B Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRM418A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIHHTRM436A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRM454A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIHHTRN436A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRN454A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIHHTRN472A Factory Installed 72 KW Electric Heat See Unit Price SheetsFIHHTRJ418A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIHHTRJ436A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRAW18B Factory Installed 18 KW Electric Heat See Unit Price SheetsFIHHTRAW27B Factory Installed 27 KW Electric Heat See Unit Price SheetsFIHHTRMW18A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIHHTRMW36A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRMW54A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIHHTRNW54A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIHHTRNW72A Factory Installed 72 KW Electric Heat See Unit Price SheetsFIHHTRJW18A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIHHTRJW36A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRN318A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIHHTRN418A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIHHTRNW18A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIHHTRP336A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRQ336A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRP436A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRQ436A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRPW36A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRP354A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIHHTRQ354A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIHHTRP454A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIHHTRQ454A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIHHTRPW54A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIHHTRQW54A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIYHTRP105A Factory Installed 6 KW Electric Heat See Unit Price SheetsFIYHTRP110A Factory Installed 10 KW Electric Heat See Unit Price SheetsFIYHTRP114A Factory Installed 14 KW Electric Heat See Unit Price SheetsFIYHTRP118A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIYHTRP306A Factory Installed 6 KW Electric Heat See Unit Price SheetsFIYHTRP312A Factory Installed 12 KW Electric Heat See Unit Price SheetsFIYHTRP318A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIYHTRP323A Factory Installed 23 KW Electric Heat See Unit Price SheetsFIYHTRP406A Factory Installed 6 KW Electric Heat See Unit Price SheetsFIYHTRP412A Factory Installed 12 KW Electric Heat See Unit Price SheetsFIYHTRP418A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIYHTRP423A Factory Installed 23 KW Electric Heat See Unit Price SheetsFIYHTRPW06A Factory Installed 6 KW Electric Heat See Unit Price SheetsFIYHTRPW12A Factory Installed 12 KW Electric Heat See Unit Price SheetsFIYHTRPW18A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIYHTRPW23A Factory Installed 23 KW Electric Heat See Unit Price Sheets

Page 254: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

FIOPS-5 Effective 1/1/06

Table FIOPS-5-A — AccessoriesModelNumber Description Used WithElectric Heat - Heat PumpMust be factory installed when using with Through-the-Base Electrical option.FIYHTRP105A Factory Installed 6 KW Electric Heat See Unit Price SheetsFIYHTRP110A Factory Installed 10 KW Electric Heat See Unit Price SheetsFIYHTRP114A Factory Installed 14 KW Electric Heat See Unit Price SheetsFIYHTRP118A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIYHTRP306A Factory Installed 6 KW Electric Heat See Unit Price SheetsFIYHTRP312A Factory Installed 12 KW Electric Heat See Unit Price SheetsFIYHTRP318A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIYHTRP323A Factory Installed 23 KW Electric Heat See Unit Price SheetsFIYHTRP406A Factory Installed 6 KW Electric Heat See Unit Price SheetsFIYHTRP412A Factory Installed 12 KW Electric Heat See Unit Price SheetsFIYHTRP418A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIYHTRP423A Factory Installed 23 KW Electric Heat See Unit Price SheetsFIYHTRPW06A Factory Installed 6 KW Electric Heat See Unit Price SheetsFIYHTRPW12A Factory Installed 12 KW Electric Heat See Unit Price SheetsFIYHTRPW18A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIYHTRPW23A Factory Installed 23 KW Electric Heat See Unit Price SheetsFIDHTRA327B Factory Installed 27 KW Electric Heat See Unit Price SheetsFIDHTRA336B Factory Installed 36 KW Electric Heat See Unit Price SheetsFIDHTRB309B Factory Installed 9 KW Electric Heat See Unit Price SheetsFIDHTRB318B Factory Installed 18 KW Electric Heat See Unit Price SheetsFIDHTRD318A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIDHTRD336A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIDHTRD354A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIDHTRK318A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIDHTRK336A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIDHTRK354A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIDHTRL336A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIDHTRL354A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIDHTRK372A Factory Installed 72 KW Electric Heat See Unit Price SheetsFIDHTRA409B Factory Installed 9 KW Electric Heat See Unit Price SheetsFIDHTRA418B Factory Installed 18 KW Electric Heat See Unit Price SheetsFIDHTRA427B Factory Installed 27 KW Electric Heat See Unit Price SheetsFIDHTRA436B Factory Installed 36 KW Electric Heat See Unit Price SheetsFIDHTRC418A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIDHTRD418A Factory Installed 9 KW Electric Heat See Unit Price SheetsFIDHTRD436A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIDHTRD454A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIDHTRK436A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIDHTRK454A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIDHTRL436A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIDHTRL454A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIDHTRK472A Factory Installed 72 KW Electric Heat See Unit Price SheetsFIDHTRAW18B Factory Installed 18 KW Electric Heat See Unit Price SheetsFIDHTRAW27B Factory Installed 27 KW Electric Heat See Unit Price SheetsFIDHTRCW18A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIDHTRCW36A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIDHTRCW54A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIDHTRDW18A Factory installed 18 KW Electric Heat See Unit Price Sheets

Downflow/Horizontal PackagedCooling,Packaged Gas/Electric/Packaged HeatPump Factory Installed Options (FIOPS)

Page 255: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

FIOPS-6Effective 1/1/06

Table FIOPS-6-A — AccessoriesModelNumber Description Used WithElectric Heat - Heat Pump (Contd.)FIDHTRDW54A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIDHTRKW36A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIDHTRKW54A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIDHTRLW36A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIDHTRMW36A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIDHTRKW72A Factory Installed 72 KW Electric Heat See Unit Price SheetsFIHHTRA327B Factory Installed 27 KW Electric Heat See Unit Price SheetsFIHHTRA336B Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRB309B Factory Installed 9 KW Electric Heat See Unit Price SheetsFIHHTRB318B Factory Installed 18 KW Electric Heat See Unit Price SheetsFIHHTRD318A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIHHTRD336A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRD354A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIHHTRM318A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIHHTRM336A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRM354A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIHHTRN336A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRN354A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIHHTRN372A Factory Installed 72 KW Electric Heat See Unit Price SheetsFIHHTRA409B Factory Installed 9 KW Electric Heat See Unit Price SheetsFIHHTRA418B Factory Installed 18 KW Electric Heat See Unit Price SheetsFIHHTRA427B Factory Installed 27 KW Electric Heat See Unit Price SheetsFIHHTRA436B Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRM418A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIHHTRD418A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIHHTRM436A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRM454A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIHHTRN436A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRN454A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIHHTRN472A Factory Installed 72 KW Electric Heat See Unit Price SheetsFIHHTRAW18B Factory Installed 18 KW Electric Heat See Unit Price SheetsFIHHTRAW27B Factory Installed 27 KW Electric Heat See Unit Price SheetsFIHHTRMW18A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIHHTRMW36A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRCW54A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIHHTREW36A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRMW54A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIHHTRNW36A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRNW54A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIHHTRNW72A Factory Installed 72 KW Electric Heat See Unit Price SheetsFIHHTRMW54A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIHHTRNW54A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIHHTRNW72A Factory Installed 72 KW Electric Heat See Unit Price SheetsFIHHTRN318A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIHHTRNW18A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIHHTRP336A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRP436A Factory Installed 36 KW Electric Heat See Unit Price SheetsFIHHTRP454A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIHHTRQW54A Factory Installed 54 KW Electric Heat See Unit Price SheetsFIHHTRP418A Factory Installed 18 KW Electric Heat See Unit Price SheetsFIHHTRQW36A Factory Installed 18 KW Electric Heat See Unit Price Sheets

Downflow/Horizontal PackagedCooling,Packaged Gas/Electric/Packaged HeatPump Factory Installed Options (FIOPS)

Page 256: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

FIOPS-7 Effective 1/1/06

Table FIOPS-7-A — AccessoriesModelNumber Description Used WithEnthalpy KitsFIYENTH007A Reference Enthalpy Downflow Units w/A,C or G in 10th DigitFIYENTH008A Comparative Enthalpy Downflow Units w/A,C or G in 10th DigitFilter & Control Access(Downflow units only)FIYHNGE004A Hinged Filter/Evap. and Comp./Control Access Door TC/YCD150,180,210, WCD150-180FIYHNGE005A Hinged Filter/Evap. and Comp./Control Access Door TC/YCD300FIYHNGE008A Hinged Filter/Evap. and Comp./Control Access Door TC/YCD151FIYHNGE009A Hinged Filter/Evap. and Comp./Control Access Door TC/YCD181,211,240,241,301, WCD240FrostatFIYLOAM023A Frostat TC/YCD151,181,241 with H,J,K,L in 10th digit

w/FIYABRD002BHigh Efficiency MotorsCan be used on downflow or horizontal units unless specified on matrix sheets.FIYHEMT001A 2 HP High Effic. Motor (86.5 Eff.)(208-230/460/60/3) Consult Matrix SheetsFIYHEMT002A 2 HP High Effic. Motor (86.5 Eff.)(575/60/3) Consult Matrix SheetsFIYHEMT003A 3 HP High Effic. Motor (89.5 Eff.)(208-230/60/3) Consult Matrix SheetsFIYHEMT004A 3 HP High Effic. Motor (89.5 Eff.)(460/60/3) Consult Matrix SheetsFIYHEMT005A 3 HP High Effic. Motor (89.5 Eff.)(575/60/3) Consult Matrix SheetsFIYHEMT006A 5 HP High Effic. Motor (91.0 Eff.)(208-230/60/3) Consult Matrix SheetsFIYHEMT007A 5 HP High Effic. Motor (91.0 Eff.)(460/60/3) Consult Matrix SheetsFIYHEMT008A 5 HP High Effic. Motor (91.0 Eff.)(575/60/3) Consult Matrix SheetsFIYHEMT009A 7½ HP High Effic. Motor (90.2 Eff.)(208-230/60/3) Consult Matrix SheetsFIYHEMT010A 7½ HP High Effic. Motor (90.2 Eff.)(460/60/3) Consult Matrix SheetsFIYHEMT011A 7½ HP High Effic. Motor (90.2 Eff.)(575/60/3) Consult Matrix SheetsLCIFIYLTCI003B Comm-5 LonTalk Interface TC/YC*150-301, WC*150-240Novar Controls-2024The Novar control option includes the following factory installed and wired devices: Novar ETM-2024 rooftop controller, fan proving switch, cloggedfilter or unit shutdown switch, Cool 1,Cool 2, Heat switch and discharge air sensor (downflow only) (Novar # DTS-30, 20-170°F). NOTE: Optioncannot be ordered in conjunction with FIOPS Smoke Detector option.FIYCNTL013A Novar Control, 208-230V T/YCD150-301*3FIYCNTL015A Novar Control, 460 & 575V T/ YCD150-301*4,WNovar Controls-3051The Novar control option includes the following factory installed and wired devices: Novar 3051 rooftop controller, fan proving switch, clogged filter orunit shutdown switch, and discharge air sensor (Novar # DTS-30, 20-170°F) (downflow only). NOTE: This option can be ordered in conjunction withfactory installed Smoke Detector option. It can also be ordered with 100% DB economizer but not with enthalpy controls.FIYCNTL016A Novar Control, 460V, 575V TC/ YCD181,211,240,241,300,301*4,WFIYCNTL017A Novar Control, 208-230V TC/ YCD150,151,180,210*3FIYCNTL018A Novar Control, 460V, 575V TC/YCD150,151,180,210*4,WFIYCNTL019A Novar Control, 208-230V TC/YCD181,211,240,241,300,301*3Novar Return Air SensorThis option consists of the Novar return air sensor (Novar # WTS-10) that is wired and shipped in the return air section of the unit. The sensorships with approximately 15' of extra wire for dropping down the return air duct (downflow only).FIYNRAS001A Return Air Sensor FIYCNTL013A and FIYCNTL015ANovar Zone SensorThis option consists of a Novar Zone Sensor (Novar #WTS-SOS) used with Novar 3051 Controls.FIYNZSR001A Novar Zone Sensor for Novar 3051 FIYCNTL016AReliaTelTM Options ModuleFIYABRD002B is required when ordering the following accessories: Clogged Filter Switch (FIYDFPS005A/BAYDFPS005A), Fan Fail Switch (FIYDFPS006A/BAYDFPS006A), Discharge Air Sensing Kit (FIYTUBE008A,FIYTUBE009A, BAYTUBE008A, BAYTUBE009A), Frostat (FIYLOAM023A, BAYLOAM023A),Ventilation Override (must order BAYVNOR002B), Smoke Detector (FIYSMDT).FIYABRD002B ReliaTelTM Options Module All Voyager Units

Downflow/Horizontal Packaged Cooling,Packaged Gas/Electric/Packaged HeatPump Factory Installed Options (FIOPS)

Page 257: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

FIOPS-8Effective 1/1/06

Table FIOPS-8-A — AccessoriesModelNumber Description Used WithSmoke Detector (Return Air) for downflow units with economizer123Option cannot be ordered in conjunction with field installed economizer.FIYSMDT221A Return Air Smoke Detector TC/YCD150,151,180,210, WCD150,180FIYSMDT223A Return Air Smoke Detector TC/YCD181,211,240,241,300,301, WCD240Smoke Detector (Return Air) for downflow units without economizer123FIYSMDT222A Return Air Smoke Detector TC/YCD150,151,180,210, WCD150,180FIYSMDT224A Return Air Smoke Detector TC/YCD181,211,240,241,300,301, WCD240Smoke Detector (Supply Air) for downflow units 23

FIYSMDT225A Supply Air Smoke Detector TC/ YCD150,151,180,210, WCD150B-180FIYSMDT228A Supply Air Smoke Detector TC/ YCD181,211,240,241,300,301, WCD240Smoke Detectors (Supply and Return Air) for downflow units with economizer123Option cannot be ordered in conjunction with field installed economizer.FIYSMDT226A Supply and Return Air Smoke Detector TC/ YCD150,151,180,210, WCD150,180FIYSMDT229A Supply and Return Air Smoke Detector TC/YCD181,211,240,241,300,301, WCD240Smoke Detectors (Supply and Return Air ) for downflow units without economizer123

FIYSMDT227A Supply and Return Air Smoke Detector TC/ YCD150,151,180,210, WCD150,180BFIYSMDT230A Supply and Return Air Smoke Detector TC/YCD181,211,240,241,300,301, WCD240B1 The return air smoke detector may not fit up or work properly on the Voyager units when used in conjunction with 3rd party accessories (such as bolt on

heat wheels, economizers, and power exhaust). Do not order the return air smoke detectors when using this type of accessory.2 Smoke Detectors available for downflow units only.3 Functional only with ReliaTel ™ Options Module (FIYABR002B).Stainless Steel Heat ExchangerFIYSSHX001A 150 MBH Stainless Steel Heat Exchanger YC*150,151 Low HeatFIYSSHX002A 250 MBH Stainless Steel Heat Exchanger YC*150,151 High Heat

YC*155,175,180,181,200,210,211,240,241,250,300 and301 Low Heat

FIYSSHX003A 350 MBH Stainless Steel Heat Exchanger YC*155,175,180,181,210,211 High HeatFIYSSHX004A 400 MBH Stainless Steel Heat Exchanger YC*200,240,241,250,300,301 High HeatSwitches1

FIYDFPS005A Clogged Filter Switch All Voyager UnitsFIYDFPS006A Fan Failure Switch All Voyager Units1 Functional only with ReliaTel ™ Options Module (FIYABR002B).TCIFIYICSI004B Trane Communication Interface All Units w/B or C in 10th Digit and

- when combination of oversize TXV Units w/H, J, K or L in 10th Digitmotor and TCI is required.

Downflow/Horizontal PackagedCooling,Packaged Gas/Electric/Packaged HeatPump Factory Installed Options (FIOPS)

Page 258: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

FIOPS-9 Effective 1/1/06

Table FIOPS-9-A — AccessoriesModelNumber Description Used WithThrough the Base ElectricalMust be used with Unit Mounted Disconnect Switch or Unit Mounted Circuit Breaker (downflow only). When adding heat, must order Trane Electric Heat. If no factory installed UnitMounted disconnect Switch or Unit Mounted Circuit Breaker is required, order the Through the Base Utility Access Option (FIYTBUA****)FIYTBUE206A Through-the-Base Electrical Option Consult Matrix SheetsFIYTBUE207A Through-the-Base Electrical Option Consult Matrix SheetsFIYTBUE208A Through-the-Base Electrical Option Consult Matrix SheetsFIYTBUE209A Through-the-Base Electrical Option Consult Matrix SheetsFIYTBUE210A Through-the-Base Electrical Option Consult Matrix SheetsFIYTBUE211A Through-the-Base Electrical Option Consult Matrix SheetsFIYTBUE212A Through-the-Base Electrical Option Consult Matrix SheetsFIYTBUE213A Through-the-Base Electrical Option Consult Matrix SheetsFIYTBUE214A Through-the-Base Electrical Option Consult Matrix SheetsFIYTBUE215A Through-the-Base Electrical Option Consult Matrix SheetsFIYTBUE216A Through-the-Base Electrical Option Consult Matrix SheetsThrough The Base Gas PipingFIYTBUG202A1 Through-the-Base Gas Piping YCD150,151 Low & High Heat

YCD180-301 Low HeatFIYTBUG203A1 Through-the-Base Gas Piping YCD180-301 High HeatFIYTBUG205A2 Through-the-Base Gas Piping YCD150,151 Low & High Heat

YCD180-301 Low HeatFIYTBUG206A2 Through-the-Base Gas Piping YCD180-301 High Heat

1 Must order when ordering through-the-base electrical or through-the-base access option (downflow only).2 Order when not ordering through-the-base electrical or through-the-base access option (downflow only).Through the Base Utilities AccessOrder this accessory when no factory installed Unit Mounted Disconnect Switch or Unit Mounted Circuit Breaker is required. If factory installed Unit MountedDisconnect or Unit Mounted Circuit Breaker is required, order the Through the Base Electrical Option (FIYTBUE****) from the FIOP Matrix page.FIYTBUA204A Through the Base Utilities Access YCD150,151,180,210FIYTBUA205A Through the Base Utilities Access TCD150,151,180,210, WCD150,180FIYTBUA206A Through the Base Utilities Access YCD181,211,240,241,300,301FIYTBUA207A Through the Base Utilities Access TCD181,211,240,241,300,301, WCD240,300Tool-less Condenser Hail GuardFIYGARD001B Tool-less Condenser Hail Guard TC/YC*150, WC*150FIYGARD002B Tool-less Condenser Hail Guard TC/YC*151,180,210, WC*180FIYGARD003A Tool-less Condenser Hail Guard TC/YC*181,211,240,241,301,WC*240FIYGARD005A Tool-less Condenser Hail Guard TC/YC*3002" Pleated FiltersFIYPLTD001A 2" Pleated Filters TC/YC*150,151,180,210, WC*150,180FIYPLTD002A 2" Pleated Filters TC/YCD181,211,240,241,300,301, WCD240FIYPLTD003A 2" Pleated Filters TC/YCH181,211,240,241,300,301, WCH240

Downflow/Horizontal Packaged Cooling,Packaged Gas/Electric/Packaged HeatPump Factory Installed Options (FIOPS)

Page 259: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

FIOPS-10Effective 1/1/06

Do

wn

flow

Pac

kag

ed C

oo

ling

, & G

as E

lect

ric

Fac

tory

Inst

alle

d O

ptio

ns

(FIO

PS

)M

atri

x P

age

FAC

TOR

Y IN

STA

LL

ED

OP

TIO

NS

(FIO

PS

)(1

)U

nit m

odel

# c

hang

es to

"F

" in

2nd

dig

it, in

dica

ting

desi

re fo

r fa

ctor

y in

stal

led

optio

ns (

unit

nam

epla

te w

ill s

till r

efle

ct s

tand

ard

mod

el #

, i.e

. T/Y

CD

).(2

)U

nit m

ount

ed d

isco

nnec

t and

circ

uit b

reak

ers

are

mut

ually

exc

lusi

ve o

f eac

h ot

her.

(3)

Thr

ough

-the

-bas

e el

ectr

ical

opt

ion

mus

t be

orde

red

with

eith

er u

nit m

ount

ed d

isco

nnec

t or c

ircui

t bre

aker

. Whe

n ad

ding

hea

t, m

ust o

rder

Tra

ne E

lect

ric H

eat.

(4)

Whe

n or

derin

g ec

onom

izer

("A

" in

10t

h di

git)

, TC

I ("F

" in

10t

h di

git)

, or

econ

omiz

er a

nd T

CI (

"G"

in 1

0th

digi

t) u

se li

ne w

ith m

odel

num

ber

with

"0"

in 1

0th

digi

t for

FIO

P s

elec

tions

; whe

n or

derin

g ov

ersi

zed

mot

or (

"B"

in 1

0th

digi

t) o

r ov

ersi

zed

mot

or &

eco

nom

izer

("C

" in

10t

h di

git)

use

s lin

e w

ith m

odel

num

ber

with

"B

" in

10t

hdi

git f

or F

IOP

sel

ectio

ns. W

hen

orde

ring

ther

mal

exp

ansi

on v

alve

("H

" in

10t

h di

git)

with

eco

nom

izer

("L

" in

10t

h di

git)

use

line

with

mod

el n

umbe

r w

ith "

H"

in th

e 10

thdi

git f

or F

IOP

sel

ectio

ns; w

hen

orde

ring

ther

mal

exp

ansi

on v

alve

with

ove

rsiz

ed m

otor

("J

" in

10t

h di

git)

or

over

size

d m

otor

& e

cono

miz

er (

"K"

in 1

0th

digi

t) u

ses

line

with

mod

el n

umbe

r w

ith "

J" in

10t

h di

git f

or F

IOP

sel

ectio

ns.

(5)

Hig

h ef

ficie

ncy

mot

ors

can

be fa

ctor

y in

stal

led

on d

ownf

low

and

hor

izon

tal u

nits

unl

ess

note

d. W

hen

orde

ring

horiz

onta

l uni

ts w

ith h

igh

effic

ienc

y m

otor

s,un

it m

odel

# c

hang

es to

"H

" in

3rd

dig

it.C

O*

= C

oolin

g O

nly

G

E*

= G

as E

lect

ric

AL

L FA

CT

OR

Y IN

STA

LL

ED

OP

TIO

NS

AR

E B

UIL

T-T

O-O

RD

ER

.C

HE

CK

OR

DE

R S

ER

VIC

ES

FO

RE

ST

IMA

TE

D P

RO

DU

CT

ION

CY

CL

E.

High

Effi

cien

cyTh

roug

h-th

e-Ba

se E

lect

rical

Unit

Mou

nted

Dis

conn

ect

Unit

Mou

nted

Circ

uit B

reak

erM

odel

Mot

ors

FIYT

BUE_

__A

(3)

FIYU

DC__

__A

(2)

FIYU

CB__

__A

(2)

Num

ber (

1)(4

)FI

YHEM

T___

A (5

)(D

ownf

low

Onl

y)(D

ownf

low

Onl

y)(D

ownf

low

Onl

y)C

O* (

*=0)

Coo

ling

&C

O* &

CO

* &G

E* (*

= L

or H

Hea

t)G

as E

lect

ricC

O*/G

E*18

KW27

KW36

KW54

KW72

KWG

E*18

KW27

KW36

KW54

KW72

KWG

E*18

KW27

KW36

KW54

KW72

KWT/

YFD

150D

3*0B

003

207/

206

208

N/A

209

210

N/A

6100

6100

N/A

4150

3250

N/A

4080

4080

N/A

6125

3200

N/A

T/YF

D15

0D3*

BB00

620

7/20

620

8N

/A20

921

0N

/A61

0061

00N

/A41

5032

50N

/A40

8040

80N

/A41

5032

00N

/AT/

YFD

150D

4*0B

004

207/

206

208

N/A

208

208

N/A

6100

6100

N/A

6100

6100

N/A

4040

4040

N/A

4070

4090

N/A

T/YF

D15

0D4*

BB00

720

7/20

620

8N

/A20

820

8N

/A61

0061

00N

/A61

0061

00N

/A40

4040

40N

/A40

7041

00N

/AT/

YFD

150D

W*0

B00

520

7/20

620

8N

/A20

820

8N

/A61

0061

00N

/A61

0061

00N

/A40

3040

30N

/A40

5040

70N

/AT/

YFD

150D

W*B

B00

820

7/20

620

8N

/A20

820

8N

/A61

0061

00N

/A61

0061

00N

/A40

3540

35N

/A40

6040

80N

/AT/

YFD

151C

3*0B

003

207/

206

208

N/A

209

210

N/A

6100

6100

N/A

4150

3250

N/A

4080

4080

N/A

6125

3200

N/A

T/YF

D15

1C3*

BB00

620

7/20

620

8N

/A20

921

0N

/A61

0061

00N

/A41

5032

50N

/A40

9040

90N

/A41

5032

00N

/AT/

YFD

151C

4*0B

004

207/

206

208

N/A

208

208

N/A

6100

6100

N/A

6100

6100

N/A

4040

4040

N/A

4070

4090

N/A

T/YF

D15

1C4*

BB00

720

7/20

620

8N

/A20

820

8N

/A61

0061

00N

/A61

0061

00N

/A40

4040

40N

/A40

7041

00N

/AT/

YFD

151C

W*0

B00

520

7/20

620

8N

/A20

820

8N

/A61

0061

00N

/A61

0061

00N

/A40

3040

30N

/A40

5040

70N

/AT/

YFD

151C

W*B

B00

820

7/20

620

8N

/A20

820

8N

/A61

0061

00N

/A61

0061

00N

/A40

3540

35N

/A40

6040

80N

/AT/

YFD

151C

3*H

B00

320

7/20

620

8N

/A20

921

0N

/A61

0061

00N

/A41

5032

50N

/A40

7040

70N

/A61

2532

00N

/AT/

YFD

151C

3*JB

006

207/

206

208

N/A

209

210

N/A

6100

6100

N/A

4150

3250

N/A

4080

4080

N/A

4150

3200

N/A

T/YF

D15

1C4*

HB

004

207/

206

208

N/A

208

208

N/A

6100

6100

N/A

6100

6100

N/A

4035

4035

N/A

4070

4090

N/A

T/YF

D15

1C4*

JB00

720

7/20

620

8N

/A20

820

8N

/A61

0061

00N

/A61

0061

00N

/A40

4040

40N

/A40

7041

00N

/AT/

YFD

151C

W*H

B00

520

7/20

620

8N

/A20

820

8N

/A61

0061

00N

/A61

0061

00N

/A40

3040

30N

/A40

5040

70N

/AT/

YFD

151C

W*J

B00

820

7/20

620

8N

/A20

820

8N

/A61

0061

00N

/A61

0061

00N

/A40

3040

30N

/A40

6040

80N

/AT/

YFD

180B

3*0H

003

207/

206

208

N/A

209

210

N/A

6100

6100

N/A

4150

3250

N/A

4090

4100

N/A

6125

3200

N/A

T/YF

D18

0B3*

BH00

620

7/20

620

8N

/A20

921

0N

/A61

0061

00N

/A41

5032

50N

/A41

0041

00N

/A41

5032

00N

/AT/

YFD

180B

4*0H

004

207/

206

208

N/A

208

208

N/A

6100

6100

N/A

6100

6100

N/A

4050

4050

N/A

4070

4090

N/A

T/YF

D18

0B4*

BH00

720

7/20

620

8N

/A20

820

8N

/A61

0061

00N

/A61

0061

00N

/A40

5040

50N

/A40

7041

00N

/AT/

YFD

180B

W*0

H00

520

7/20

620

8N

/A20

820

8N

/A61

0061

00N

/A61

0061

00N

/A40

4040

40N

/A40

5040

70N

/AT/

YFD

180B

W*B

H00

820

7/20

620

8N

/A20

820

8N

/A61

0061

00N

/A61

0061

00N

/A40

4040

40N

/A40

6040

80N

/AT/

YFD

181C

3*0C

003

213/

212

214

N/A

215

216

N/A

6100

6100

N/A

4150

3250

N/A

4090

4100

N/A

6125

3200

N/A

T/YF

D18

1C3*

BC00

621

3/21

221

4N

/A21

521

6N

/A61

0061

00N

/A41

5032

50N

/A41

0041

00N

/A41

5032

00N

/AT/

YFD

181C

4*0C

004

213/

211

214

214

214

214

N/A

6100

6100

6100

6100

6100

N/A

4050

4050

4050

4070

4090

N/A

T/YF

D18

1C4*

BC00

721

3/21

121

4N

/A21

421

4N

/A61

0061

00N

/A61

0061

00N

/A40

5040

50N

/A40

7041

00N

/AT/

YFD

181C

W*0

C00

521

3/21

121

4N

/A21

421

4N

/A61

0061

00N

/A61

0061

00N

/A40

4040

40N

/A40

5040

70N

/AT/

YFD

181C

W*B

C00

821

3/21

121

4N

/A21

421

4N

/A61

0061

00N

/A61

0061

00N

/A40

4040

40N

/A40

6040

80N

/AT/

YFD

181C

3*H

C00

321

3/21

221

4N

/A21

521

6N

/A61

0061

00N

/A41

5032

50N

/A40

9041

00N

/A61

2532

00N

/AT/

YFD

181C

3*JC

006

213/

212

214

N/A

215

216

N/A

6100

6100

N/A

4150

3250

N/A

4090

4090

N/A

4150

3200

N/A

T/YF

D18

1C4*

HC

004

213/

211

214

214

214

214

N/A

6100

6100

6100

6100

6100

N/A

4050

4050

4050

4070

4090

N/A

T/YF

D18

1C4*

JC00

721

3/21

121

4N

/A21

421

4N

/A61

0061

00N

/A61

0061

00N

/A40

5040

50N

/A40

7041

00N

/AT/

YFD

181C

W*H

C00

521

3/21

121

4N

/A21

421

4N

/A61

0061

00N

/A61

0061

00N

/A40

4040

40N

/A40

5040

70N

/AT/

YFD

181C

W*J

C00

821

3/21

121

4N

/A21

421

4N

/A61

0061

00N

/A61

0061

00N

/A40

4040

40N

/A40

6040

80N

/A

Page 260: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

FIOPS-11 Effective 1/1/06

High

Effi

cien

cyTh

roug

h-th

e-Ba

se E

lect

rical

Unit

Mou

nted

Dis

conn

ect

Unit

Mou

nted

Circ

uit B

reak

erM

odel

Mot

ors

FIYT

BUE_

__A

(3)

FIYU

DC__

__A

(2)

FIYU

CB__

__A

(2)

Num

ber (

1)(4

)FI

YHEM

T___

A (5

)(D

ownf

low

Onl

y)(D

ownf

low

Onl

y)(D

ownf

low

Onl

y)C

O* (

*=0)

Coo

ling

&C

O* &

GE*

= (*

= L

or H

Hea

t)G

as E

lect

ricC

O*/G

E*18

KW27

KW36

KW54

KW72

KWG

E*18

KW27

KW36

KW54

KW72

KWC

O*/G

E*18

KW27

KW36

KW54

KW72

KWT/

YFD

210C

3*0E

006

207/

206

N/A

N/A

209

210

N/A

6100

N/A

N/A

4150

3250

N/A

4100

/410

0N

/AN

/A41

5032

00N

/AT/

YFD

210C

3*BE

009

207/

206

N/A

N/A

209

210

N/A

4150

N/A

N/A

4150

3250

N/A

6125

/412

5N

/AN

/A41

5032

00N

/AT/

YFD

210C

4*0E

007

207/

206

N/A

N/A

208

208

N/A

6100

N/A

N/A

6100

6100

N/A

4050

/405

0N

/AN

/A40

7041

00N

/AT/

YFD

210C

4*BE

010

207/

206

N/A

N/A

208

208

N/A

6100

N/A

N/A

6100

6100

N/A

4060

/406

0N

/AN

/A40

7041

00N

/AT/

YFD

210C

W*0

E00

820

7/20

6N

/AN

/A20

820

8N

/A61

00N

/AN

/A61

0061

00N

/A40

45/4

045

N/A

N/A

4060

4080

N/A

T/YF

D21

0CW

*BE

011

207/

206

N/A

N/A

208

208

N/A

6100

N/A

N/A

6100

6100

N/A

4045

/404

5N

/AN

/A40

6040

80N

/AT/

YFD

211C

3*0C

006

213/

212

N/A

N/A

215

216

216

4150

N/A

N/A

4150

3250

3250

6110

/411

0N

/AN

/A41

5032

0032

50T/

YFD

211C

3*BC

009

213/

212

N/A

N/A

215

216

216

4150

N/A

N/A

4150

3250

3250

6125

/412

5N

/AN

/A41

5032

0032

50T/

YFD

211C

4*0C

007

213/

211

N/A

214

214

214

215

6100

N/A

6100

6100

6100

4150

4060

/406

0N

/A40

6040

7041

0061

25T/

YFD

211C

4*BC

010

213/

211

N/A

N/A

214

214

215

6100

N/A

N/A

6100

6100

4150

4060

/406

0N

/AN

/A40

7041

0061

25T/

YFD

211C

W*0

C00

821

3/21

1N

/AN

/A21

421

421

461

00N

/AN

/A61

0061

0061

0040

45/4

045

N/A

N/A

4060

4080

4100

T/YF

D21

1CW

*BC

011

213/

211

N/A

N/A

214

214

215

6100

N/A

N/A

6100

6100

6100

4050

/405

0N

/AN

/A40

6040

8041

00T/

YFD

240B

3*0J

006

213/

212

N/A

N/A

215

216

216

4150

N/A

N/A

4150

3250

3250

6125

/412

5N

/AN

/A41

5032

0032

50T/

YFD

240B

3*BJ

009

213/

212

N/A

N/A

215

216

216

4150

N/A

N/A

4150

3250

3250

6125

/412

5N

/AN

/A41

5032

0032

50T/

YFD

240B

4*0J

007

213/

211

N/A

N/A

214

214

215

6100

N/A

N/A

6100

6100

4150

4060

/406

0N

/AN

/A40

7041

0061

25T/

YFD

240B

4*BJ

010

213/

211

N/A

N/A

214

214

215

6100

N/A

N/A

6100

6100

4150

4060

/406

0N

/AN

/A40

7041

0061

25T/

YFD

240B

W*0

J00

821

3/21

1N

/AN

/A21

421

421

461

00N

/AN

/A61

0061

0061

0040

45/4

045

N/A

N/A

4060

4080

4100

T/YF

D24

0BW

*BJ

011

213/

211

N/A

N/A

214

214

215

6100

N/A

N/A

6100

6100

6100

4050

/405

0N

/AN

/A40

6040

8041

00T/

YFD

241C

3*0C

006

213/

212

N/A

N/A

215

216

216

4150

N/A

N/A

4150

3250

3250

6125

/412

5N

/AN

/A41

5032

0032

50T/

YFD

241C

3*BC

009

213/

212

N/A

N/A

215

216

216

4150

N/A

N/A

4150

3250

3250

6125

/412

5N

/AN

/A41

5032

0032

50T/

YFD

241C

4*0C

007

213/

211

N/A

214

214

214

215

6100

N/A

6100

6100

6100

4150

4060

/406

0N

/A40

6040

7041

0061

25T/

YFD

241C

4*BC

010

213/

211

N/A

N/A

214

214

215

6100

N/A

N/A

6100

6100

4150

4060

/406

0N

/AN

/A40

7041

0061

25T/

YFD

241C

W*0

C00

821

3/21

1N

/AN

/A21

421

421

461

00N

/AN

/A61

0061

0061

0040

50/4

050

N/A

N/A

4060

4080

4100

TFD

241C

W*B

C01

121

3/21

1N

/AN

/A21

421

421

561

00N

/AN

/A61

0061

0061

0040

50/4

050

N/A

N/A

4060

4080

4100

T/YF

D24

1C3*

HC

006

213/

212

N/A

N/A

215

216

216

4150

N/A

N/A

4150

3250

3250

6125

/412

5N

/AN

/A41

5032

0032

50T/

YFD

241C

3*JC

009

213/

212

N/A

N/A

215

216

216

4150

N/A

N/A

4150

3250

3250

6125

/412

5N

/AN

/A41

5032

0032

50T/

YFD

241C

4*H

C00

721

3/21

1N

/A21

421

421

421

561

00N

/A61

0061

0061

0041

5040

60/4

060

N/A

4060

4070

4100

6125

T/YF

D24

1C4*

JC01

021

3/21

1N

/AN

/A21

421

421

561

00N

/AN

/A61

0061

0041

5040

70/4

070

N/A

N/A

4070

4100

6125

T/YF

D24

1CW

*HC

008

213/

211

N/A

N/A

214

214

214

6100

N/A

N/A

6100

6100

6100

4050

/405

0N

/AN

/A40

6040

8041

00T/

YFD

241C

W*J

C01

121

3/21

1N

/AN

/A21

421

421

561

00N

/AN

/A61

0061

0061

0040

50/4

050

N/A

N/A

4060

4080

4100

Do

wn

flow

Pac

kag

ed C

oo

ling

, & G

as E

lect

ric

Fac

tory

Inst

alle

d O

ptio

ns

(FIO

PS

)M

atri

x P

age

(Co

ntd

.)

FAC

TOR

Y IN

STA

LL

ED

OP

TIO

NS

(FIO

PS

)(1

)U

nit m

odel

# c

hang

es to

"F

" in

2nd

dig

it, in

dica

ting

desi

re fo

r fa

ctor

y in

stal

led

optio

ns (

unit

nam

epla

te w

ill s

till r

efle

ct s

tand

ard

mod

el #

, i.e

. T/Y

CD

).(2

)U

nit m

ount

ed d

isco

nnec

t and

circ

uit b

reak

ers

are

mut

ually

exc

lusi

ve o

f eac

h ot

her.

(3)

Thr

ough

-the

-bas

e el

ectr

ical

opt

ion

mus

t be

orde

red

with

eith

er u

nit m

ount

ed d

isco

nnec

t or c

ircui

t bre

aker

. Whe

n ad

ding

hea

t, m

ust o

rder

Tra

ne E

lect

ric H

eat.

(4)

Whe

n or

derin

g ec

onom

izer

("A

" in

10t

h di

git)

, TC

I ("F

" in

10t

h di

git)

, or

econ

omiz

er a

nd T

CI (

"G"

in 1

0th

digi

t) u

se li

ne w

ith m

odel

num

ber

with

"0"

in 1

0th

digi

t for

FIO

P s

elec

tions

; whe

n or

derin

g ov

ersi

zed

mot

or (

"B"

in 1

0th

digi

t) o

r ov

ersi

zed

mot

or &

eco

nom

izer

("C

" in

10t

h di

git)

use

s lin

e w

ith m

odel

num

ber

with

"B

" in

10t

hdi

git f

or F

IOP

sel

ectio

ns. W

hen

orde

ring

ther

mal

exp

ansi

on v

alve

("H

" in

10t

h di

git)

with

eco

nom

izer

("L

" in

10t

h di

git)

use

line

with

mod

el n

umbe

r w

ith "

H"

in th

e 10

thdi

git f

or F

IOP

sel

ectio

ns; w

hen

orde

ring

ther

mal

exp

ansi

on v

alve

with

ove

rsiz

ed m

otor

("J

" in

10t

h di

git)

or

over

size

d m

otor

& e

cono

miz

er (

"K"

in 1

0th

digi

t) u

ses

line

with

mod

el n

umbe

r w

ith "

J" in

10t

h di

git f

or F

IOP

sel

ectio

ns.

(5)

Hig

h ef

ficie

ncy

mot

ors

can

be fa

ctor

y in

stal

led

on d

ownf

low

and

hor

izon

tal u

nits

unl

ess

note

d. W

hen

orde

ring

horiz

onta

l uni

ts w

ith h

igh

effic

ienc

y m

otor

s,un

it m

odel

# c

hang

es to

"H

" in

3rd

dig

it.C

O*

= C

oolin

g O

nly

GE

* =

Gas

Ele

ctric

AL

L FA

CT

OR

Y IN

STA

LL

ED

OP

TIO

NS

AR

E B

UIL

T-T

O-O

RD

ER

.C

HE

CK

OR

DE

R S

ER

VIC

ES

FO

RE

ST

IMA

TE

D P

RO

DU

CT

ION

CY

CL

E.

Page 261: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

FIOPS-12Effective 1/1/06

High

Effi

cien

cyTh

roug

h-th

e-Ba

se E

lect

rical

Unit

Mou

nted

Dis

conn

ect

Unit

Mou

nted

Circ

uit B

reak

erM

odel

Mot

ors

FIYT

BUE_

__A

(3)

FIYU

DC__

__A

(2)

FIYU

CB__

__A

(2)

Num

ber (

1)(4

)FI

YHEM

T___

A (5

)(D

ownf

low

Onl

y)(D

ownf

low

Onl

y)(D

ownf

low

Onl

y)C

O* (

* = 0

)C

oolin

g &

CO

* &C

O* &

GE*

= (L

or H

Hea

t)G

as E

lect

ricC

O*/G

E*18

KW27

KW36

KW54

KW72

KWG

E*18

KW27

KW36

KW54

KW72

KWG

E*18

KW27

KW36

KW54

KW72

KWT/

YFD

300B

3*0H

009

213/

212

N/A

N/A

215

216

216

4150

N/A

N/A

4150

3250

3250

4150

N/A

N/A

4150

3200

3250

T/YF

D30

0B4*

0H01

021

3/21

1N

/AN

/A21

421

421

561

00N

/AN

/A61

0061

0041

5040

70N

/AN

/A40

7041

0061

25T/

YFD

300B

W*0

H01

121

3/21

1N

/AN

/A21

421

421

561

00N

/AN

/A61

0061

0061

0040

50N

/AN

/A40

6040

8041

00T/

YFD

301C

3*0C

009

213/

212

N/A

N/A

215

216

216

4150

N/A

N/A

4150

3250

3250

4150

N/A

N/A

4150

3200

3250

T/YF

D30

1C4*

0C01

021

3/21

1N

/A21

421

421

421

561

00N

/A61

0061

0061

0041

5040

70N

/A40

7040

7041

0061

25T/

YFD

301C

W*0

C01

121

3/21

1N

/AN

/A21

421

421

561

00N

/AN

/A61

0061

0061

0040

60N

/AN

/A40

6040

8041

00

Do

wn

flow

Pac

kag

ed C

oo

ling

, & G

as E

lect

ric

Fac

tory

Inst

alle

d O

ptio

ns

(FIO

PS

)M

atri

x P

age

(Co

ntd

.)

FAC

TOR

Y IN

STA

LL

ED

OP

TIO

NS

(FIO

PS

)(1

)U

nit m

odel

# c

hang

es to

"F

" in

2nd

dig

it, in

dica

ting

desi

re fo

r fa

ctor

y in

stal

led

optio

ns (

unit

nam

epla

te w

ill s

till r

efle

ct s

tand

ard

mod

el #

, i.e

. T/Y

CD

).(2

)U

nit m

ount

ed d

isco

nnec

t and

circ

uit b

reak

ers

are

mut

ually

exc

lusi

ve o

f eac

h ot

her.

(3)

Thr

ough

-the

-bas

e el

ectr

ical

opt

ion

mus

t be

orde

red

with

eith

er u

nit m

ount

ed d

isco

nnec

t or c

ircui

t bre

aker

. Whe

n ad

ding

hea

t, m

ust o

rder

Tra

ne E

lect

ric H

eat.

(4)

Whe

n or

derin

g ec

onom

izer

("A

" in

10t

h di

git)

, TC

I ("F

" in

10t

h di

git)

, or

econ

omiz

er a

nd T

CI (

"G"

in 1

0th

digi

t) u

se li

ne w

ith m

odel

num

ber

with

"0"

in 1

0th

digi

t for

FIO

P s

elec

tions

; whe

n or

derin

g ov

ersi

zed

mot

or (

"B"

in 1

0th

digi

t) o

r ov

ersi

zed

mot

or &

eco

nom

izer

("C

" in

10t

h di

git)

use

s lin

e w

ith m

odel

num

ber

with

"B

" in

10t

hdi

git f

or F

IOP

sel

ectio

ns. W

hen

orde

ring

ther

mal

exp

ansi

on v

alve

("H

" in

10t

h di

git)

with

eco

nom

izer

("L

" in

10t

h di

git)

use

line

with

mod

el n

umbe

r w

ith "

H"

in th

e 10

thdi

git f

or F

IOP

sel

ectio

ns; w

hen

orde

ring

ther

mal

exp

ansi

on v

alve

with

ove

rsiz

ed m

otor

("J

" in

10t

h di

git)

or

over

size

d m

otor

& e

cono

miz

er (

"K"

in 1

0th

digi

t) u

ses

line

with

mod

el n

umbe

r w

ith "

J" in

10t

h di

git f

or F

IOP

sel

ectio

ns.

(5)

Hig

h ef

ficie

ncy

mot

ors

can

be fa

ctor

y in

stal

led

on d

ownf

low

and

hor

izon

tal u

nits

unl

ess

note

d. W

hen

orde

ring

horiz

onta

l uni

ts w

ith h

igh

effic

ienc

y m

otor

s,un

it m

odel

# c

hang

es to

"H

" in

3rd

dig

it.C

O*

= C

oolin

g O

nly

GE

* =

Gas

Ele

ctric

AL

L FA

CTO

RY

INS

TAL

LE

D O

PT

ION

S A

RE

BU

ILT-

TO

-OR

DE

R.

CH

EC

K O

RD

ER

SE

RV

ICE

S F

OR

ES

TIM

AT

ED

PR

OD

UC

TIO

N C

YC

LE

.

Page 262: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

FIOPS-13 Effective 1/1/06

(1)

Uni

t mod

el #

cha

nges

to "

F"

in 2

nd d

igit,

indi

catin

g de

sire

for

fact

ory

inst

alle

d op

tions

(un

it na

mep

late

will

stil

l ref

lect

sta

ndar

d m

odel

#, i

.e. W

CD

).(2

)U

nit m

ount

ed d

isco

nnec

t and

circ

uit b

reak

ers

are

mut

ually

exc

lusi

ve o

f eac

h ot

her.

(3)

Thr

ough

-the

-bas

e el

ectr

ical

opt

ion

mus

t be

orde

red

with

eith

er u

nit m

ount

ed d

isco

nnec

t or

circ

uit b

reak

er. W

hen

addi

ng h

eat,

mus

t ord

er T

rane

Ele

ctric

Hea

t.(4

)W

hen

orde

ring

econ

omiz

er (

"A"

in 1

0th

digi

t), T

CI (

"F"

in 1

0th

digi

t), o

r ec

onom

izer

and

TC

I ("G

" in

10t

h di

git)

use

line

with

mod

el n

umbe

r w

ith "

0" in

10t

h di

git f

or F

IOP

sel

ectio

ns; w

hen

orde

ring

over

size

d m

otor

("B

" in

10t

h di

git)

or

over

size

d m

otor

& e

cono

miz

er (

"C"

in 1

0th

digi

t) u

ses

line

with

mod

el n

umbe

r w

ith "

B"

in 1

0th

dig

it fo

r F

IOP

sel

ectio

ns.

(5)

Hig

h ef

ficie

ncy

mot

ors

can

be fa

ctor

y in

stal

led

on d

ownf

low

and

hor

izon

tal u

nits

unl

ess

note

d. W

hen

orde

ring

horiz

onta

l uni

ts w

ith h

igh

effic

ienc

y m

otor

s, u

nit m

odel

# c

hang

es to

"H

" in

3rd

dig

it.*

Coo

ling

Onl

y

FAC

TOR

Y IN

STA

LL

ED

OP

TIO

NS

(FIO

PS

)

Hig

h E

ffic

ien

cyT

hro

ug

h-t

he-

Bas

e E

lect

rica

lU

nit

Mo

un

ted

Dis

con

nec

tU

nit

Mo

un

ted

Cir

cuit

Bre

aker

Mo

del

Mo

tors

FIY

TB

UE

___A

(3)

FIY

UD

C__

__A

(2)

FIY

UC

B__

__A

(2)

Nu

mb

er (

1)F

IYH

EM

T__

_A (

5)(D

ow

nfl

ow

On

ly)

(Do

wn

flo

w O

nly

)(D

ow

nfl

ow

On

ly)

CO

*18

KW

36K

W54

KW

72K

WC

O*

18K

W36

KW

54K

W72

KW

CO

*18

KW

36K

W54

KW

72K

WW

FD

150B

300G

003

207

209

210

210

N/A

6100

4150

3250

3250

N/A

4080

6125

3175

3250

N/A

WF

D15

0B30

BG

006

207

209

210

210

N/A

6100

4150

3250

3250

N/A

4080

4150

3200

3250

N/A

WF

D15

0B40

0G00

420

720

820

820

9N

/A61

0061

0061

0041

50N

/A40

4040

6040

9061

25N

/AW

FD

150B

40B

G00

720

720

820

820

9N

/A61

0061

0061

0041

50N

/A40

4040

7040

9061

25N

/AW

FD

150B

W00

G00

520

720

820

820

8N

/A61

0061

0061

0061

00N

/A40

3040

5040

7040

90N

/AW

FD

150B

W0B

G00

820

720

820

820

8N

/A61

0061

0061

0061

00N

/A40

3540

5040

8041

00N

/A

Do

wn

flow

Pac

kag

ed H

eat P

um

pF

acto

ry In

stal

led

Op

tion

s (F

IOP

S)

Mat

rix

Pag

e

with

out

aux.

hea

tw

ithou

tau

x. h

eat

with

out

aux.

hea

t

Page 263: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

FIOPS-14Effective 1/1/06

Hig

h E

ffic

ien

cyT

hro

ug

h-t

he-

Bas

e E

lect

rica

lU

nit

Mo

un

ted

Dis

con

nec

tU

nit

Mo

un

ted

Cir

cuit

Bre

aker

Mo

del

Mo

tors

FIY

TB

UE

___A

(3)

FIY

UD

C__

__A

(2)

FIY

UC

B__

__A

(2)

Nu

mb

er (

1)F

IYH

EM

T__

_A (

5)(D

ow

nfl

ow

On

ly)

(Do

wn

flo

w O

nly

)(D

ow

nfl

ow

On

ly)

CO

*18

KW

36K

W54

KW

72K

WC

O*

18K

W36

KW

54K

W72

KW

CO

*18

KW

36K

W54

KW

72K

WW

FD

180B

300G

003

207

209

210

210

N/A

6100

4150

3250

3250

N/A

4090

4150

3200

3250

N/A

WF

D18

0B30

BG

006

207

209

210

NA

N/A

6100

4150

3250

3250

N/A

4100

4150

3200

3250

N/A

WF

D18

0B40

0G00

420

720

820

820

9N

/A61

0061

0061

0041

50N

/A40

4540

7041

0061

25N

/AW

FD

180B

40B

G00

720

720

820

920

9N

/A61

0061

0061

0041

50N

/A40

5040

7041

0061

25N

/AW

FD

180B

W00

G00

520

720

820

820

9N

/A61

0061

0061

0061

00N

/A40

3540

6040

8041

00N

/AW

FD

180B

W0B

G00

820

720

820

820

9N

/A61

0061

0061

0061

00N

/A40

4040

6040

8041

00N

/AW

FD

240B

300G

006

213

N/A

216

216

N/A

4150

N/A

3250

NA

N/A

6125

N/A

3225

NA

N/A

WF

D24

0B30

BG

009

213

N/A

216

NA

N/A

4150

N/A

3250

NA

N/A

6125

N/A

3225

NA

N/A

WF

D24

0B40

0G00

721

3N

/A21

521

5N

/A61

00N

/A41

5041

50N

/A40

60N

/A61

1041

50N

/AW

FD

240B

40B

G01

021

3N

/A21

521

5N

/A61

00N

/A41

5041

50N

/A40

60N

/A61

1041

50N

/AW

FD

240B

W00

G00

821

3N

/A21

421

521

561

00N

/A61

0041

5041

5040

45N

/A40

9061

1061

25W

FD

240B

W0B

G01

121

3N

/A21

421

521

561

00N

/A61

0041

5041

5040

50N

/A40

9061

1041

50

AL

L FA

CTO

RY

INS

TAL

LE

D O

PT

ION

S A

RE

BU

ILT-

TO

-OR

DE

R.

CH

EC

K O

RD

ER

SE

RV

ICE

S F

OR

ES

TIM

AT

ED

PR

OD

UC

TIO

N C

YC

LE

.

(1)

Uni

t mod

el #

cha

nges

to "

F"

in 2

nd d

igit,

indi

catin

g de

sire

for

fact

ory

inst

alle

d op

tions

(un

it na

mep

late

will

stil

l ref

lect

sta

ndar

d m

odel

#, i

.e. W

CD

).(2

)U

nit m

ount

ed d

isco

nnec

t and

circ

uit b

reak

ers

are

mut

ually

exc

lusi

ve o

f eac

h ot

her.

(3)

Thr

ough

-the

-bas

e el

ectr

ical

opt

ion

mus

t be

orde

red

with

eith

er u

nit m

ount

ed d

isco

nnec

t or

circ

uit b

reak

er. W

hen

addi

ng h

eat,

mus

t ord

er T

rane

Ele

ctric

Hea

t.(4

)W

hen

orde

ring

econ

omiz

er (

"A"

in 1

0th

digi

t), T

CI (

"F"

in 1

0th

digi

t), o

r ec

onom

izer

and

TC

I ("G

" in

10t

h di

git)

use

line

with

mod

el n

umbe

r w

ith "

0" in

10t

h di

git f

or F

IOP

sel

ectio

ns; w

hen

orde

ring

over

size

d m

otor

("B

" in

10t

h di

git)

or

over

size

d m

otor

& e

cono

miz

er (

"C"

in 1

0th

digi

t) u

ses

line

with

mod

el n

umbe

r w

ith "

B"

in 1

0th

dig

it fo

r F

IOP

sel

ectio

ns.

(5)

Hig

h ef

ficie

ncy

mot

ors

can

be fa

ctor

y in

stal

led

on d

ownf

low

and

hor

izon

tal u

nits

unl

ess

note

d. W

hen

orde

ring

horiz

onta

l uni

ts w

ith h

igh

effic

ienc

y m

otor

s, u

nit m

odel

# c

hang

es to

"H

" in

3rd

dig

it.*

C

oolin

g O

nly

FAC

TOR

Y IN

STA

LL

ED

OP

TIO

NS

(FIO

PS

)

Do

wn

flow

Pac

kag

ed H

eat P

um

pF

acto

ry In

stal

led

Op

tion

s (F

IOP

S)

Mat

rix

Pag

e (C

on

td.)

with

out

aux.

hea

tw

ithou

tau

x. h

eat

with

out

aux.

hea

t

Page 264: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

CCZO-1 Effective 1/1/06

Comfort ControlDefinitions

Manual or MechanicalDifferential

The difference (Degrees F) betweencut-in and cut-out temperature with noelectrical load connected to thethermostat.

Operating DifferentialThe difference (Degrees F) incut-in and cut-out temperature whenthe thermostat is actually operatingequipment. Operating differential isless than mechanical differential.

RangeMinimum to maximum temperaturescale shown on dial.

SensorA device that measures andcommunicates temperature of theconditioned space in which it islocated to a system controller.

Set PointThe temperature at which thethermostat indicator is set.

Two Piece ThermostatSystem consisting of a sensormounted in the controlled spacecommunicating to a controller whichestablishes the systems operation.

Power Stealing 4 WireResistor Terminal in Box. 4-wiresystem to supply power with heatingmode; steals power from "y" incooling.

CalibrationThe relationship of the dial setting andthe cut-in temperature of thethermostat.

ComfortLinkTM

An open architecture communicationsbridge for reliably interfacing toautomation and energy managementsystems.

Cut-in PointThe temperature at which thethermostat calls for system operation.

Cut-out PointThe temperature at which thethermostat stops calling forheating or cooling.

Cycle RateThe number of times per hour that theheating equipment is cycled on athalf load conditions.

DroopAn indoor temperature controlcondition where the room remainsbelow the thermostat setting. Thiscontrol occurs in mild coolingconditions and is caused by thecooling anticipator resistor whichprovides a false heat source: forthe thermostat to maintain relativehumidity control.

Heat Anticipator(Sometimes called a PreheatResistor.)

A bias heater that shuts off thethermostat before the roomreaches the thermostat setting.

Page 265: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

CCZO-2Effective 1/1/06

Programmable 7 DayComfort Controls

TCONT800A• Interactive Touchscreen• Effortless Programming• Large, Backlit Display• Streamlined Design• Armchair Programming• Real Time Clock• Visual Reminder Cues• BAYCOVR600A - Wall cover plate• Energy Star

TCONT802A• Interactive Touchscreen• Effortless Programming• Large, Backlit Display• Streamlined Design• Armchair Programming• Real Time Clock• Visual Reminder Cues• BAYCOVR600A - Wall cover plate• Energy Star

TCONT803A• Built-in Humidity Sensor• Dehumidification Control• Interactive Touchscreen• Effortless Programming• Large, Backlit Display• Streamlined Design• Armchair Programming• Real Time Clock• Visual Reminder Cues• BAYCOVR600A - Wall cover plate• Energy Star

Application:• Up to 3 Heat/2 Cool

(Gas, Oil or Electric)/HP• ZZSENSAL0800AA - Remote Indoor

Temperature SensorDimensions:

• 6.02” w x 4.62” h• Finish: Bright White

Application:• 1 Heat/1 Cool (Gas, Oil or Electric)• 1 Heat/0 Cool (Gas, Oil or Electric)• 0 Heat/1 Cool• ZZSENSAL0800AA - Remote Indoor

Temperature SensorDimensions:• 6.02” w x 4.62” h• Finish: Bright White

BAYCOVR600AApplication:• Use with TCONT800A Series Comfort

Controls

• Finish: Bright White

Application:• Up to 3 Heat/2 Cool

(Gas, Oil or Electric)/HP• ZZSENSAL0800AA - Remote Indoor

Temperature SensorDimensions:• 6.02” w x 4.62” h• Finish: Bright White

Page 266: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

CCZO-3 Effective 1/1/06

PHASEDOUT

PHASEDOUT

Programmable 7 DayComfort Controls

TAYSTAT302CXT302C• 2 Heat/2 Cool• 7 Day, 24 Hour or Constant

Temperature Programming• 4 Temperature Set Points Per Day• Manual or Auto Changeover (Field

Selectable)• Outdoor Temperature Display (Optional

Accessory – TAYSENS100A)

• Bright Backlight Display• Filter Clean/Replacement Key (FieldAd-

justable)• No Batteries Required; Super Cap

Continues Clock for an Average of30 Minutes

• Programming and Other FunctionsStored in Permanent “E-PROM” Memory

• Must be set for 2 Heat/2 Cool by installer• Factory shipped 2 Heat/ 1 Cool• Conventional or Adaptive Intelligent

Recovery (Field Selectable)• Daylight Savings Time Key• Programmable Fan – Fan can be

Programmed in the “ON” or “AUTO”Mode for Each Period

• Minimum Compressor Run Time(Factory Set to 10 Minutes, FieldAdjustable)

• Vacation/Leave Program; Will HoldVacation/Leave Temperature for up to256 Days

• Field Temperature Re-Calibration Offset(Field Adjustable); Allows Installer to SetThermostat to Customer’s Wall -Mounted Thermostat Setting

• Fan-On Heat with Terminal (Heat/CoolModels, Field Adjustable); i.e. Fan “G”is Activated with “W” (Electric HeatInstallations)

• “Comfort "R"™” Enhanced Cooling forPSC Motors, Field Activated (This isOnly a Portion of Comfort "R"™ that isAchieved with Variable Speed Equip-ment)

• Finish: Bright White

• Filter Clean/Replacement Key (FieldAdjustable)

• No Batteries Required; Super CapContinues Clock for an Average of30 Minutes

• Field Select 1 or 2 Stage• Programming and Other Functions

Stored in Permanent “E-PROM” Memory• Conventional or Adaptive Intelligent

Recovery (Field Selectable)• Factory shipped 2 Heat/1 Cool• If needed, Installation setup allows

control to be used in 3 Heat/1 Cool• Daylight Savings Time Key• Programmable Fan – Fan can be

Programmed in the “ON” or “AUTO”Mode for Each Period

TAYSTAT500CXT500C• 2 Heat/1 Cool• 3 Heat/2 Cool Heat Pumps• 7 Day, 24 Hour or Constant

Temperature Programming• 4 Temperature Set Points Per Day• Manual or Auto Changeover (FieldSe-

lectable)• Outdoor Temperature Display

(Optional Accessory – TAYSENS100A)• Bright Backlight Display

• Minimum Compressor Run Time (FactorySet to 10 Minutes, Field Adjustable)

• Vacation/Leave Program; Will HoldVacation/Leave Temperature for up to256 Days

• Field Temperature Re-Calibration Offset(Field Adjustable); Allows Installer to SetThermostat to Customer’s Wall-MountedThermostat Setting

• Fan-On Heat with Terminal (Heat/CoolModels, Field Adjustable); i.e. Fan “G” isActivated with “W” (Electric HeatInstallations)

• “Comfort "R"™” Enhanced Cooling forPSC Motors, Field Activated (This is Onlya Portion of Comfort "R"™ that isAchieved with Variable Speed Equipment)

• Finish: Bright White

Phased

Out

Phased

Out

PHASEDOUT

TAYSTAT300CXT300C• Single Stage Heating/Cooling• 7 Day, 24 Hour or Constant

Temperature Programming• 4 Temperature Set Points Per Day• Power Stealing 4-wire• Manual or Auto Changeover (Field

Selectable)

• Outdoor Temperature Display (OptionalAccessory – TAYSENS100A)

• Bright Backlight Display• 4-wire hook up-register is supplied for

systems with electric heat• Filter Clean/Replacement Key (Field

Adjustable)• No Batteries Required; Super Cap

Continues Clock for an Average of30 Minutes

• Programming and Other FunctionsStored in Permanent “E-PROM” Memory

• Conventional or Adaptive IntelligentRecovery (Field Selectable)

• Daylight Savings Time Key• Gas only models do not need resistor• Programmable Fan – Fan can be

Programmed in the “ON” or “AUTO”Mode for Each Period

Phased

Out

• Minimum Compressor Run Time(Factory Set to 10 Minutes, FieldAdjustable)

• Vacation/Leave Program; Will HoldVacation/Leave Temperature for up to256 Days

• Field Temperature Re-Calibration Offset(Field Adjustable); Allows Installer to SetThermostat to Customer’s Wall-MountedThermostat Setting

• Fan-On Heat with Terminal (Heat/CoolModels, Field Adjustable); i.e. Fan “G”is Activated with “W” (Electric HeatInstallations)

• “Comfort "R"™” Enhanced Cooling forPSC Motors, Field Activated (This isOnly a Portion of Comfort "R"™ that isAchieved with Variable Speed Equip-ment)

• Finish: Bright White

Page 267: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

CCZO-4Effective 1/1/06

PHASED OUT

PHASED OUT• 2 Heat (Gas)/1 Cool• Heat/Off/Cool System Switch• 5/2 Programmable• Auto/On Fan Switch• Manual Changeover• Super Cap Continues Clock for an

Average of 30 Minutes

• 2 Heat/1 Cool• Heat/Off/Cool/Emergency Heat

System Switch• 5/2 Programmable• Auto/On Fan Switch• Manual Changeover• Super Cap Continues Clock for an

Average of 30 Minutes

• Programming Stored In Permanent“E-PROM” Memory

• No Batteries• Adjustable Heating Cycle Rate• 6-wire connection• Finish: Bright White

• Programming Stored In Permanent“E-PROM” Memory

• No Batteries• Adjustable Heating Cycle Rate• Finish: Bright White

TCONT602A

Application:• Use with TCONT600A Series Comfort

Controls

• Finish: Bright White

Programmable 5/2 DayComfort Controls

TCONT600A

• 1 Heat/1 Cool• 5/2 or 5/1/1 Programming• Simple to Install and Use• Front Wired (Wires attach to wall

plates)• Standard Wiring Terminal Block• Easy to follow Sequential Program-

ming• Inside and set temperatures displayed

simultaneously

• Plain language (no symbols)• Easy battery access• Easy to understand soft key controls• Energy Star• BAYCOVR700A - Wall cover plateDimensions:• 5.81” w x 3.56” h• Finish: Bright White

• 2 Heat/2 Cool• 5/2 or 5/1/1 Programming• Simple to Install and Use• Front Wired (Wires attach to wall

plates)• Standard Wiring Terminal Block• Easy to follow Sequential

Programming• Inside and set temperatures displayed

simultaneously

• Plain language (no symbols)• Easy battery access• Easy to understand soft key controls• BAYCOVR700A - Wall cover plate• Energy StarDimensions:• 5.81” w x 3.56” h• Finish: Bright White

PHASED OUTPhasedOut

TAYSTAT340

• 1 Heat (Gas/Electric)/1 Cool• Heat/Off/Cool System Switch• Power Stealing 4 Wire• 5/2 Programmable• Auto/On Fan Switch• Manual Changeover• Super Cap Continues Clock for an

Average of 30 Minutes

• Programming Stored In Permanent“E-PROM” Memory

• No Batteries• Fuel Selection Switch (Gas/Electric)• Adjustable Heating Cycle Rate• Finish: Bright White

TAYSTAT350

PhasedOut

PhasedOut

Heat PumpTAYSTAT540

BAYCOVR700A

Page 268: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

CCZO-5 Effective 1/1/06

Non-ProgrammableComfort Controls

TCONT401A• Auto Changeover• Backlit Display & Keys• Comfort Information Compartment• Energy Savings Mode• Filter Reminder• Outdoor Temperature Sensor• Keypad LockApplication (3-9 Wire Hookup -2

for Outdoor Sensor) Heat Pump*or A/C

• 1 Stage Heat Pump**, 1 Stage AuxHeat

• 1 Stage Heat Pump**, 0 Stage AuxHeat

• 1 Stage Cool, 2 Stage Heat(Gas, Electric or Oil*)

• 1 Stage Cool, 1 Stage Heat(Gas, Electric or Oil*)

• 1 Stage Cool, 0 Stage Heat• 0 Stage Cool, 2 Stage Heat

(Gas, Electric or Oil*)• 0 Stage Cool, 1 Stage Heat

(Gas, Electric or Oil*)Dimensions:

6.75" w x 4.52" h• Finish: Bright White* Requires external relay for oil furnace

applications.** External TAYPLUS103A required for

dual fuel applications.BAYSEN01ATEMPAA required foroutdoor temperature sensing anddisplay

TCONT402A• Auto Changeover• Backlit Display & Keys• Comfort Information Compartment• Energy Savings Mode• Filter Reminder• BAYSEN01ATEMPAA-Outdoor

Temperature Sensor included*• Keypad LockApplication (3-9 Wire Hookup -2

for Outdoor Sensor) Heat Pump*or A/C

• 3 Heat/2 Cool• No external Dual Fuel Kit Required• ZZSENSAL0400AA - Remote Indoor

Temperature Sensor

Dimensions:6.75" w x 4.52" h

• Finish: Bright White* Requires external relay for oil furnace

applications.* Installation is required for outdoor

temperature sensing and display* BAYSEN01ATEMPAA required for

outdoor temperature sensing anddisplay

TCONT200A• Auto Changeover• Back Lit Display & Keys• Comfort Information Compartment• Energy Savings Mode• Filter Reminder• Key Pad Lock

Dimensions:• 4.25" (W) x 5.33" (H)Application (4 wire hookup - power

stealing)*• 1 Heat/1 Cool (Gas, Oil or electric)• 1 Heat/0 Cool (Gas, Oil or electric)• 0 Heat/1 Cool• Finish: Bright White

Page 269: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

CCZO-6Effective 1/1/06

PHASED OUT

PHASED OUT

PHASED OUT

PHASED OUT

PHASED OUT

PHASED OUT

TAYSTAT371• 1 Heat (Electric)/1 Cool• Power Stealing 4 Wire• Resistor must be installed (shipped

with control)• Heat/Off/Cool System Switch• Auto/On Fan Switch

• Manual Changeover• Digital Display• No Batteries• Permanent Temperature Setting

Retention• Finish: Bright White

TAYSTAT370• 1 Heat (Gas)/1 Cool• Power Stealing 4 Wire• Heat/Off/Cool System Switch• Auto/On Fan Switch• Manual Changeover

Non-ProgrammableComfort Controls

TAYSTAT380• 2 Heat (Gas)/1 Cool• Heat/Off/Cool System Switch• Auto/On Fan Switch• Manual Changeover• Digital Display

Heat PumpTAYSTAT570• 2 Heat /1 Cool• Heat/Off/Cool/Emergency Heat

System Switch• Auto/On Fan Switch• Manual Changeover

• No Batteries• Permanent Temperature Setting

Retention• Adjustable Heating Cycle Rate• Finish: Bright White

PhasedOut

• Digital Display• No Batteries• Permanent Temperature Setting

Retention• Finish: Bright White

TAYSTAT375• 2 Heat (Gas/Electric) /2 Cool (Field

Selectable)• Factory Ships 2 Heat/1 Cool• Lighted Digital Display• Permanent Temperature Setting

Retention

Heat

Heat PumpTAYSTAT575• 3 Heat /2 Cool (Field Selectable)• Factory Ships 2 Heat/1 Cool• Lighted Digital Display• Emergency Heat/Off/Cool Auto System

Keyboard

Heat

• Auto/On Fan Switch Keyboard• No Batteries• Manual or Auto Changeover• Permanent Temperature Setting

Retention• Finish: Bright White

PhasedOut

• Heat/Off/Cool/Auto System Keyboard• Auto/On Fan Switch Keyboard• Manual or Auto Changeover• No Batteries• Finish: Bright White

• Digital Display• No Batteries• Permanent Temperature Setting

Retention• Adjustable Heating Cycle Rate

• Finish: Bright White

PhasedOut

PhasedOut

PhasedOut

PhasedOut

Page 270: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

CCZO-7 Effective 1/1/06

PHASED OUT• Finish: Bright White

Remote Sensors

BAYSEN02ATEMPAA• Outdoor Temperature Sensor for Use

with TCONT800, 802, 803• Accuracy +/– 1°F from –40 to 120°F

ZZSENSAL0800AA• Indoor Temperature Sensor for Use

with TCONT800, 802, 803• Operating Ambient Temperature

Range: 45 to 88°F (7.2 to 32°C)• Display Range: 0 to 99°F (-18 to 37°C)• Sensor Accuracy: +/-1.5°F at 70°F

(+/-.84 at 21°C)• Operating Relative Humidity: 5% to

95% non-condensing

BAYSEN01ATEMPAA• Outdoor Temperature Sensor for Use

with TCONT401A & 402A• Accuracy

+/- 15°F over 32°F to 100°F• Display Range

-40°F to 140°F

Phased

Out

ZZSENSAL0400AA• Indoor Sensor for Use with

TCONT402 Comfort Controls• Operating Ambient Temperature

Range: 20° to 120°F (-6.7° to 48.9°C)• Display Range: 20° to 120°F

(-6.7° to 48.9°C)• Sensor Accuracy: +/-.5°F at 75°F• Operating Relative Humidity: 5% to

90% non-condensing

Dimensions in in. (mm):• 1.54 (39) wide x 1.93 (49) high x .625

(1.6) deep• Storage Temperature: -40° to 140°F

(-40° to 60°C)• Finish: White

Dimensions in in. (mm):• 1.50 (38) wide x 2.28 (58) high x .70

(18) deep• Finish: White

TAYSENS100A• Outdoor Temperature Sensor for Use

with TAYSTAT300C, 302C, 500C, 575and 375

• Accuracy +/– 1°F from –40 to 120°F

Page 271: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

CCZO-8Effective 1/1/06

Humidity Control

• Heating Cycle Humidity ControlThe humidity control provides automaticlow voltage control of humidifiers incentral heating and cooling applications.It has an spst, snap-acting, dust-proofswitch that opens when humidity risesabove the control setting. It is designedfor wall or surface duct mounting.

• Cooling Cycle Humidity*When activated, the humidity controllowers the furnace/air handler blowerspeed, reducing air velocity over thefurnace/air handler coil and removing agreater amount of moisture from the air.

• Bright White Finish

* For use w/variable speed indoor products"ONLY"

BAYSTAT253A

Humidity Control

• BAY24X042 relay for fan operationwhen using electric heat.

• This sample hook-up diagramillustrates Field Connections forcooling only units, electric heat andautomatic change over control.

• On a call for heat, the relay providesfor instant fan-on. Without the relay,you will get no airflow or heat! Relayis not needed with Fossel Fuel onHeat Pump applications.

Relay Hook-Up

BAY24X042Relay

Page 272: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

CCZO-9 Effective 1/1/06

Indoor Fan Delay Relay Kit

BAY24X045• For application to furnaces and air

handlers with cooling coils equippedwith capillary tube or 15% bleedexpansion valve components.

• This kit allows the indoor fan tocontinue to run a short time after theoutdoor unit shuts off for increasedcooling efficiency.

• The kit contains: 1 solid state timedelay relay with four (4) color codedwires, 1 wiring diagram, 1 notice label,1 mounting screw.

TAYSTAT250B• The outdoor thermostat (ODT) is

designed to turn "ON" the supple-mentary heater at a pre-selectedoutdoor temperature.

• The number and setting of the ODTis dependent on the heat loss of thestructure and capacity of the heatingsystem installed.

• This model ODT gives a temperaturerange for 44°F. to -10°F. (See figure 1for settings). The switching action issingle pole/double throw, opening ontemperature rise and closing ontemperature fall, completing thecircuit through the thermostat.

Outdoor Thermostat Kit

Page 273: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

CCZO-10Effective 1/1/06

Heating OnlyBAYSTAT303• 1 Heat/0 Cool• Gas Heat Compatible• Off/Auto/Fan System Switch• Clear Plastic Set Point Lever• Not Electric Heat Compatible• Requires BAY24X042 Relay for

Indoor Fan Operation when usedfor Electric Heat

• Adjustable Heat Anticipator• Finish: Bright White

Subbase is required

(shown with 187 subbase)

Cooling Only BAY28X186• 0 Heat/2 Cool• Can be Used for Economizer Operation• Use with BAY28X187 Subbase only• Off/Auto System Switch• Auto/On Fan Switch• Clear Plastic Set Point Lever• Thermometer can be Calibrated• Finish: Beige and Gold

Cooling OnlyBAYSTAT304• 0 Heat/1 Cool• Off/Auto/Fan System Switch• Clear Plastic Set Point Lever• Finish: Bright White

Cooling Only and Heating OnlyComfort Controls

Page 274: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

CCZO-11 Effective 1/1/06

• Electric Heat Compatible; jumperterminals 1 & 2 together

• Calibrate by Adjusting the CamRider Screw

• Adjustable Heat Anticipator• Finish: Bright White

• Auto/On Fan Switch• Adjustable Heat Anticipator• Requires BAY24X042 Relay for

Indoor Fan Operation when usedfor Electric Heat

• Finish: Gold

• Requires BAY24X042 Relay forIndoor Fan Operation when usedfor Electric Heat

• Clear Plastic Set Point Levers• Adjustable Heat Anticipator• Thermometer can be Calibrated• Finish: Beige and Gold

• Electric Heat Compatible; jumperterminals 1 & 2 together

• Adjustable Heat Anticipator• Finish: Bright White

Single StageComfort Controls

Subbase is required

(shown with 185 subbase)

Single StageBAYSTAT008• 1 Heat/1 Cool• Manual Changeover• Includes Stat and Subbase• Set Point Dial• Calibrate with Honeywell Calibration

Wrench (Part #104994A)• Cool/Off Heat System Switch

Single StageBAYSTAT305• 1 Heat/1 Cool• Manual Changeover• Heat/Off/Cool System Switch• On Auto Fan Switch• Clear Plastic Set Point Lever• Gas Heat Compatible

Single StageAY28X092• 1 Heat/1 Cool• Manual Changeover• Heat/Off/Cool System Switch• On Auto Fan Switch• Set Point Dial• Gas Heat Compatible

Single StageBAY28X182• 1 Heat/1 Cool• With BAY28X185 Subbase:

Manual ChangeoverInstant On Fan (for Electric Heat)Heat/Off/Cool System SwitchAuto/On Fan Switch

• With BAY28X187 Subbase:Automatic ChangeoverOff/Auto System SwitchAuto/On Fan Switch

Page 275: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

CCZO-12Effective 1/1/06

Subbase is required

(shown with 184 subbase)

• Requires AY24X042 (DPDT Relay) forindoor fan operation when used forElectric Heat

• Finish: Bright White

• Thermometer can be Calibrated• Adjustable Heat Anticipator• Finish: Beige and Gold

• Thermometer can be Calibrated• Adjustable Heat Anticipator• Finish: Beige and Gold

• With BAY28X187 Subbase:Automatic ChangeoverOff/Auto System SwitchAuto/On Fan Switch

• Requires AY24X042 Electric HeatRelay

• Clear Plastic Set Point Levers• Adjustable Heat Anticipator• Thermometer can be Calibrated• Finish: Beige and Gold

Multiple StageComfort Controls

Multiple StageBAY28X183• 2 Heat/2 Cool-Can be Used for

Economizer Operation• With BAY28X184 Subbase:

Automatic or Manual ChangeoverOff Heat/Auto/Cool System SwitchAuto/On Fan Switch

• Requires AY24X042 Electric HeatRelay

• With BAY28X185 Subbase:Manual ChangeoverInstant On Fan (for Electric Heat)Heat/Off/Cool System SwitchAuto/On Fan Switch

Multiple StageBAYSTAT010• 2 Heat/2 Cool-Can be Used for

Economizer Operation• Automatic Changeover• Includes Stat and Subbase• Off/Auto System Switch• Auto/On Fan Switch• Clear Plastic Set Point Levers

Multiple StageBAYSTAT012• 1 Heat/2 Cool-Can be Used for

Economizer Operation• Manual Changeover• Includes Stat and Subbase• Heat/Off/Cool System Switch• Auto/On Fan Switch• Clear Plastic Set Point Levers

Multiple StageTAYSTAT241• 2 Heat/1 Cool• Manual Changeover• For 2-stage Gas Furnaces• Heat/Off/Cool System Switch• Auto/On Fan Switch• Clear Plastic Set Point Lever

Page 276: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

CCZO-13 Effective 1/1/06

Heat PumpComfort Controls

• Thermometer can be Calibrated• Clear Plastic Set Point Lever• Finish: Bright White

• Thermometer can be Calibrated• Clear Plastic Set Point Lever• Finish: Bright White

• Clear Plastic Set Point Levers• Deluxe Clear Plastic Cover• Minimum differential between Heating

and Cooling is 4°F• Thermometer can be Calibrated• Finish: Bright White

• Used with System2

• Deluxe Clear Plastic Cover• Clear Plastic Set Point Levers• Minimum differential between heating

and cooling is 4°F• Thermometer can be Calibrated• Includes Stat & Subbase• Finish: Bright White

Heat PumpBAYSTAT239A• 2 Heat/1 Cool• Manual Changeover• Includes Stat & Subbase• Heat/Off/Cool System Switch• Auto/On Fan Switch• Normal/Emergency Heat Switch• Auxiliary and Emergency Heat

Indicator Lights

Heat PumpBAYSTAT240A• 2 Heat/1 Cool• Manual Changeover• Heat/Off/Cool System Switch• Auto/On Fan Switch• Normal Emergency Heat Switch• Auxiliary and Emergency Heat

Indicator Lights

Heat PumpBAY28X138A• 2 Heat/1 Cool• Automatic Changeover• Off/Auto System Switch• Auto/On Fan Switch• Normal/Emergency Heat Switch• Auxiliary and Emergency Heat

Indicator Lights

Heat PumpBAY28X153A• 3 Heat/2 Cool• Automatic or Manual Changeover• Can be Used for Economizer

Operation• Auto Heat/Off/Cool System Switch• High Auto Low Fan Switch• Normal Emergency Heat Switch• Auxiliary and Emergency Heat

Indicator Lights

Page 277: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

CCZO-14Effective 1/1/06

Zone Comfort Controls

• Keyboard disable to prevent tampering• 100% solid state• No outdoor thermostat required, utilizes

computer controlled staging (multistage)• Auto fan during setback (optional)• No anticipator required• Automatic or Manual changeover• Built-in minimum on-off time delays

ensure short cycle protection• Lockable cover• Equipment short cycle protection against

power outages longer than 1/2 second.Equipment turns off for 6 minutes

• No accessories required. Each unit iscomplete and ready for installation

• Finish: Bright White

• Vendor: Honeywell• Finish: Bright White

BAYSTAT040B• BAYBASE008A: Single Stage

1 Heat/1 Cool• BAYBASE006A: Multi Stage

2 Heat/2 Cool-Can be used forEconomizer Operation

• BAYBASE007A: Multi StageHeat Pump-3 Heat/2 Cool-Can beused for Economizer Operation

• Digital display indicating the time ofday, the day of the week, roomtemperature, current program operat-ing mode, and current active stage

• Instant override, continuous ortemporary 3 hour timed

• Automatic adjustment of temperaturesup to four times a day

• L.C.D. readout in F or C (Celsius) and12 or 24-hour clock

• Preferential Rate Control (PRC)minimizes overshooting and preventsroom temperature deviating fromsetpoint under varying load conditions(zero droop)

• PRC provides smart recovery fromoffset to minimize use of supplementalelectric heat

Remote SensorBAYSENS033A• Remote Sensor for use with

BAYSTAT040B• Allows convenient thermostat location

and optimum temperature sensinglocation

• Maximum distance from thermostatto sensor = 1000 ft.

• Use 3 conductor (18-26 AWG)shielded, and insulated cable

BAYSENS034A• Return Air Remote Temperature

Sensor for use with BAYSTAT040B

Page 278: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

CCZO-15 Effective 1/1/06

ZSCNTRAL010

Use:• Two Piece Control• Home Automation Interface "Open Protocol"• Extensive Diagnostics and Monitoring

System

The System ControllerThe Controller is the master and center hub ofthe system. It acquires information. From theinformation it gathers, it establishes thesystem's operation. The main functions of thecontroller are communications, computation,activation and control.

ComfortLinkTM System

Must be used with any ZUSTATAL** Wall Mounted Sensor.

ZSASSMAL010

Integrated ZoneTM SystemAssembly and Accessories

• Full modulating zone operation• Single and two-stage heating products• Single and two-stage cooling products• Indoor fan motors -- handles both Variable

Speed and PSC induction motors• Heat pump compatible• Fossil fuel (gas and oil furnace)

compatible

ZSASSMAL010: Zoning AssemblyContains the Basic Control components (excluding wall mounted sensors) for either I) a three(3) zone system, or II) a two (2) zone system with by-pass. Control Components included arethe system controller, one (1) four-zone expander board with three (3) zone cards. All mountedin a metal enclosure that will accept an additional four-zone expander board for up to eight (8)zones. Discharge Air Sensor is included and packaged in a 2x2x11 box. For single and two-stage products (except XL16i); cooling, gas, oil, electric heat, and heat pump systems.

ZZEXPDAL010: Four-Zone Expander BoardUsed to expand ZSASSMAL010 Basic Zoning Assembly up to eight (8) zones or seven (7)zones with by-pass.

ZZCARDAL010: Zone/By-Pass CardControls a single zone's damper(s) or the by-pass damper. Zone and by-pass airflows are seton each card. One card required per zone.

Note: XL16i models, both cooling or heat pump models, are not approved for Trane Comfort Link™ Zoning System.

• Wet-heat (hot water coil in air handler)compatible

• Zone card adjustable from 20 to 100%system airflow

• By-pass offering• Relief to zones adjustment (standard

feature)

Page 279: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

CCZO-16Effective 1/1/06

• Remote Sensor for:– ZUSTATALS51– ZUSTATALP51– ZUSTATALMS10

• Continuously Displays:– Indoor Temperature– Thermostat Mode– Fan Mode

Sensors ForTrane ComfortLinkTM System

• Continuously Displays:– Indoor Temperature– Thermostat Mode– Programmable– Fan Mode– Time of Day– Day of Week– System Staging– Active Program

Slimline Wall Mount Zone Scheduler/Programmable Display Sensor: Same features as ZUSTATALP510 sensor.Can be used to program and schedule up to eight (8) zones. Copy button for ease of programming time/temperatureschedules from other zones. Use with ZSASSMAL010 only.

• Backlight Display• Battery Backup• Programmable Setback (Four Set Points)• Must be applied with ZSCNTRAL010• Seven Day Programming• Temporary Program Override• Hold Set Point

• Outdoor Temperature Displayupon Request (TAYSTAT265BSensor Required)

• Finish: Bright White*When used as a Two Piece

Control, ZSCNTRAL010 Mustbe Applied

ProgrammableSensorZUSTATALP510

Slimline Wall Mount Programmable Display Sensor: Same basic features as ZUSTATALS510 sensor with seven dayschedule programming which allows four separate time/tempeature settings per 24-hour period. Backlit LCD for easy viewand programming. Displays day of week in addition to time and temperature. Use with either ZSASSMAL010 orZSCNTRAL010.

ZUSTATALMS10

Slimline Wall Mount Display Sensor: Comfort sensor continuously displays the time and indoor temperature backlitLCD for easy view. Used to change indoor temperature settings and conditioning modes. When used withTAYSTAT265B sensor, outdoor temperature can be viewed. Use with either ZSASSMAL010 or ZSCNTRAL010.

• Continuously Displays:– Indoor Temperature– Thermostat Mode– Fan Mode– Time of Day– Day of Week– System Staging

Non-ProgrammableSensorZUSTATALS510

• Backlight Display• Battery Backup• Must be applied with ZSCNTRAL010• Outdoor Temperature Display upon

Request (TAYSTAT265B SensorRequired)

• Finish: Bright White

*When used as a Two Piece Control,ZSCNTRAL010 Must be Applied

CommunicatingComfort SensorZUSTATAL0310

Petite Wall Mount Display Sensor: Slimline design comfort sensor continuously displays indoor temperature. Used tochange indoor temperature settings and conditioning modes for cool, heat, auto, or continuous fan. When used withTAYSTAT265B sensor, outdoor temperature can be viewed. Used with either ZSASSMAL010 or ZSCNTRAL010. Notbacklit.

• Outdoor Temperature Display uponRequest (TAYSTAT265B SensorRequired)

• Must be applied with ZSCNTRAL010

Outdoor Temperature Sensor: Outdoor temperature only sensor. Can be used with ZUSTATALS51, ZUSTATALP51, orZUSTATALMS1. Weather proofed.

Remote Analog Temperature Sensor: Temperature only sensor. Senses the temperature where located. When usedfor a zone temperature sensor, must be used with ZUSTATALMS1 Master Scheduler. Can be used as a remote sensorfor ZUSTATALS51, ZUSTATALP51, or ZUSTATALMS1.

Room/RemoteSensorZZSENSAL011 orOutoor TemperatureSensorTAYSTAT265B

• Outdoor Sensor for:– ZUSTATALS51– ZUSTATALP51

• Finish: Bright White

• Finish: Bright White

• Finish: Bright White

• Continuously Displays:– Indoor Temperature– Thermostat Mode– Programmable– Fan Mode– Time of Day– Day of Week– System Staging– Active Program

• Backlight Display• Battery Backup• Programmable Setback (Four Set Points)• Must be applied with ZSCNTRAL010• Seven Day Programming• Temporary Program Override• Hold Set Point

• Outdoor Temperature Displayupon Request (TAYSTAT265BSensor Required)

• Finish: Bright White*When used as a Two Piece

Control, ZSCNTRAL010 Mustbe Applied

Page 280: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

CCZO-17 Effective 1/1/06

Integrated ZoneTM SystemDampers

Table CCZO-17-A — Specifications: Round DampersModel Power Fits Round Mfg. ShippingNumber Supply Description Duct Size Plant Weight Diameter LengthZD0006ALF0B0 24 VAC 6" Modulating Damper 6" TY 8 6.375 12.00ZD0008ALF0B0 24 VAC 8" Modulating Damper 8" TY 10 8.375 12.00ZD0010ALF0B0 24 VAC 10" Modulating Damper 10" TY 13 10.375 16.00ZD0012ALF0B0 24 VAC 12" Modulating Damper 12" TY 15 12.375 16.00ZD0014ALF0B0 24 VAC 14" Modulating Damper 14" TY 22 14.375 20.00ZD0016ALF0B0 24 VAC 16" Modulating Damper 16" TY 24 16.375 20.00

• Fully modulating damper• Low power requirement 2.5 VA @ 24v• Factory mounted motor actuator• 53 inch-pound running torque• 40 inch-pound break away torque• Magnetic clutch for torque protection• Adjustable rotation stops allow for minimum/

maximum airflow

• 60 second travel time• Manual gear release• Color coded wiring harness for easy field

hook-up• Low leakage Trane design• 18 guage construction• 24 volt operation

• Bottom mount actuator motor• Low power requirement 2.5 VA @ 24v• Fully modulating damper• Factory mounted motor actuator• 53 inch-pound running torque• 40 inch-pound break away torque• Magnetic clutch for torque protection• Adjustable rotation stops allow for minimum/

maximum airflow• 60 second travel time

• Manual gear release• Color coded wiring harness for easy field

hook-up• Low leakage Trane design• 18 guage construction• 24 volt operation• Long life PTC High Impact ABS gears

designed and tested to exceed 200,000cycles

Table CCZO-17-B — Specifications: Rectangular Dampers with Bottom Mount ActuatorUncrated

Model Power Dimensions (in.) Mfg. ShippingNumber Supply Description H W Plant Weight

ZD0810ALBMB0 24 VAC 8" height x 10" width 8 10 TY 16ZD0814ALBMB0 24 VAC 8" height x 14" width 8 14 TY 20ZD0820ALBMB0 24 VAC 8" height x 20" width 8 20 TY 26ZD1014ALBMB0 24 VAC 10" height x 14" width 10 14 TY 28ZD1020ALBMB0 24 VAC 10" height x 20" width 10 20 TY 35

W

H

Table CCZO-17-C — Specifications: Rectangular Dampers with Side Mount ActuatorUncrated

Model Power Dimensions (in.) Mfg. ShippingNumber Supply Description H W Plant Weight

ZD0812ALSMB0 24 VAC 8" height x 12" width 8 12 TY 17ZD0814ALSMB0 24 VAC 8" height x 14" width 8 14 TY 20ZD0816ALSMB0 24 VAC 8" height x 16" width 8 16 TY 22ZD0818ALSMB0 24 VAC 8" height x 18" width 8 18 TY 24ZD0820ALSMB0 24 VAC 8" height x 20" width 8 20 TY 26ZD1016ALSMB0 24 VAC 10" height x 16" width 10 16 TY 29ZD1020ALSMB0 24 VAC 10" height x 20" width 10 20 TY 35

• Side mount actuator motor• Low power requirement 2.5 VA @ 24v• Fully modulating damper• Factory mounted motor actuator• 53 inch-pound running torque• 40 inch-pound break away torque• Magnetic clutch for torque protection• Adjustable rotation stops allow for minimum/

maximum airflow• 60 second travel time

• Manual gear release• Color coded wiring harness for easy field

hook-up• Low leakage Trane design• 18 guage construction• 24 volt operation• Long life PTC High Impact ABS gears

designed and tested to exceed 200,000cycles

W

H

Page 281: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

CCZO-18Effective 1/1/06

Zone Sensor UnitInstallation

The zone sensor provides the operatorcontrol and zone temperature sensingfunctions for use with electronic unitcontrols. Refer to the appropriate unitinstallation manual for interconnectingwiring instructions.

ZONE SENSOR LOCATION

To ensure proper operation, select alocation on an interior wall, at a heightapproximately 5 feet above the floor,with freely circulating air of averagetemperature.

Avoid Locations:• Behind doors or in corners where air

does not freely circulate.

• On an outside wall or any wall withunheated (uncooled) areas behind thezone sensor.

• Where direct sunlight or any Source: ofradiant heat could affect thetemperature measurements.

• In line with the discharge air from theunit being controlled.

Mount the zone sensor base on thewall or optional mounting plate with thewires routed through the wire accesshole in the base of the zone sensor.

ZONE SENSOR CONTROLS

Emergency Heat/Heat/Auto/Off/Cool

This switch determines whether theunit operates in emergency heat (EM.HEAT - for heat pumps only), heating(HEAT), automatically changing fromheating to cooling as required (AUTO),heating and cooling functions disabled(OFF), or cooling (COOL).

Fan Auto/Fan OnThis switch determines whether theindoor fan operates during cooling andheating cycles only (FAN AUTO) orruns continuously (FAN ON).

Temperature AdjustmentsOne or two temperature adjustmentcontrols are provided to set thedesired temperature or temperaturerange (for unit mode AUTO). If twocontrols are present, the blue controlsets the desired temperature forcooling and the red control sets thedesired temperature for heating.

Temperature IndicatorThis indicates the temperature in thezone. The indicator has been factorycalibrated and should not normallyrequire adjustment. If adjustment isneeded, it can be accomplished byslowly rotating a small screwdriver inthe slot on the back of the indicatoruntil the correct temperature isobtained.

Optional Remote SensorWhen using the optional remotesensor (BAYSENS017B), it should belocated in the space that is to becontrolled. Wire according to theinterconnecting wiring diagrams in theunit IOM.

Installation: 18-HD60D41Source: Clarksville

Page 282: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

CCZO-19 Effective 1/1/06

• 7 wires required.• Non-Programmable Zone Sensor with

a digital display• Used with 3-25 ton packaged units.• BAYSENS035A - Cool/Gas• BAYSENS031A - Heat Pumps

LCD DigitalDisplay Zone SensorBAYSENS035A/031A

• Refer to IOM for wires required• Zone Sensor averaging only• Application where two wall mounted

sensors are required• BAYSENS032A used with 3-25 Ton

packaged Gas/Cool/Heat Pumps

Averaging RemoteZone SensorBAYSENS032A

Micro ControlsZone Sensors

MODE

• Keyboard disable to prevent tampering• Programming on a 7-day basis• Status indication lights displayed in

Digital Display• Auxiliary relay (Form 1C)• Auto Fan During Setback• No Anticipator Required• No Battery Required• No accessories required. Each unit is

complete and ready for installation• Remote Room Sensor (BAYSENS017B)• Vendor: Heatcraft 63J74• Finish: Pantone Cool Gray #2C• Replacement: SEN-0415• Installation: 18-HD60D29• Source: Clarksville

Electronic Programmable ZoneSensors For ReliaTel TM Units

BAYSENS019C• Automatic or Manual Changeover

with System Lights• Use With:

3 – 10 Ton Precedent™ Units12.5 – 25 Ton Voyager™ Units

• Digital display indicating the time ofday, the day of the week, roomtemperature, current program operat-ing mode, and current active stage

• Continuous or 3 hour timed override• Two occupied, two unoccupied

programs per day• L.C.D. readout in F or C (Celsius) and

12 or 24-hour clock

Page 283: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

CCZO-20Effective 1/1/06

• Blue Cool/Red Heat Setpoint Levers• Single Setpoint requires 4 wires for

Electric/Electric• Vendor: Sunne (62822)• Finish: Pantone Cool Gray #2C• Replacement: SEN-0410• Installation – 18-HD60D28• Source: Clarksville

• Heat Indicator Light• Blue Cool/Red Heat Setpoint Levers• Single Setpoint for heat pumps systems

requires 6 wires• Vendor: Sunne (62821)• Finish: Pantone Cool Gray #2C• Replacement: SEN-0411• Installation – 18-HD60D33• Source: Clarksville

• Auto/On Fan Switch• Blue Cool/Red Heat Setpoint Levers• Vendor: Sunne (62826)• Finish: Pantone Cool Gray #2C• Replacement: SEN-0408• Installation – 18-HD60D34• Source: Clarksville

• Normal/Emergency Heat Switch• Heat Indicator Light• Blue Cool/Red Heat Setpoint Levers• Vendor: Sunne (62825)• Finish: Pantone Cool Gray #2C• Replacement: SEN-0412• Installation – 18-HD60D35• Source: Clarksville

Electronic Zone Sensors ForReliaTelTM Units

BAYSENS006B• Single Setpoint• Manual Changeover• Use With:

3 – 10 Ton Precedent™ Units T*C, Y*C12.5 – 25 Ton Voyager™ UnitsYCD/YCH & TCD/TCH

• Heat/Off/Cool System Switch• Auto/On Fan Switch

BAYSENS007B• Single Setpoint• Manual Changeover• Use With:

3 – 10 Ton Precedent™ Units WSC12.5 – 20 Ton Voyager™ Units WCD\WCH

• Heat/Off/Cool System Switch• Auto/On Fan Switch• Normal/Emergency Heat Switch

BAYSENS008B• Dual Setpoint• Manual or Auto Changeover• Use With:

3 – 10 Ton Precedent™ Units T*C, Y*C12.5 – 25 Ton Voyager™ UnitsYCD/YCH & TCD/TCH

• Heat/Auto/Off/Cool Switch

BAYSENS009B• Dual Setpoint• Manual or Auto Changeover• Use With:

3 – 10 Ton Precedent™ Units WSC12.5 – 20 Ton Voyager™ Units WCD\WCH

• Heat/Auto/Off/Cool Switch• Auto/On Fan Switch

• System On/Heat/Cool/ServiceIndicator Lights

• Blue Cool/Red Heat Setpoint Levers• Vendor: Sunne (62823)• Finish: Pantone Cool Gray #2C• Replacement: SEN-0413• Installation – 18-HD60D36• Source: Clarksville

BAYSENS010B• Dual Setpoint• Manual or Auto Changeover• Use With:

3 – 10 Ton Precedent™ Units T*C, Y*C12.5 – 25 Ton Voyager™ Units YCD/YCH &TCD/TCH

• Heat/Auto/Off/Cool Switch• Auto/On Fan Switch

Page 284: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

CCZO-21 Effective 1/1/06

• Vendor: Sunne (65464)• Finish: Pantone Cool Gray #2C• Replacement: SEN-0495• Installation – 18-HD60D38• Source: Clarksville

• Timed Override Buttons• Thumbwheel Setpoint• Vendor: Sunne (65465)• Finish: Pantone Cool Gray #2C• Replacement: SEN-0496• Installation – 18-HD60D39• Source: Clarksville

Integrated ComfortTM SystemsSensors For ReliaTel TM Units

BAYSENS013C• Room Sensor with Timed Override• Use with Integrated ComfortTM

Systems• Use With:

3 – 10 Ton Precedent Units12.5 – 25 Ton Voyager™ Units

• Timed Override Buttons

BAYSENS014C• Room Sensor with Setpoint

Adjustment• Used with Integrated ComfortTM

Systems• Use With:

3 – 10 Ton Precedent Units12.5 – 25 Ton Voyager™ Units

• Normal/Emergency Heat Switch• System On/Heat/Cool/Service

Indicator Lights• Blue Cool/Red Heat Setpoint Levers• Vendor: Sunne (62824)• Finish: Pantone Cool Gray #2C• Replacement: SEN-0414• Installation – 18-HD60D37• Source: Clarksville

• Vendor: Sunne (62828)• Finish: Pantone Cool Gray #2C• Replacement: SEN-0435• Installation – 18-HD60D41• Source: Clarksville

Electronic Zone Sensors ForReliaTelTM Units

BAYSENS011B• Dual Setpoint• Manual or Auto Changeover• Use With:

3 – 10 Ton Precedent™ Units WSC12.5 – 20 Ton Voyager™ UnitsWCD\WCH

• Heat/Auto/Off/Cool Switch• Auto/On Fan Switch

BAYSENS017B• Remote Zone Sensor• Use With:

BAYSENS006, 007, 008, 009, 010B,011B

• Allows remote zone monitoring withstandard electronic zone sensors

Page 285: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

MINI-1 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Table MINI-1-A – Ductless High Wall - Cooling OnlySound Uncrated

Model Nominal Level Dimensions(in.) ShippingNumber Airflow (L, H) H x W x D Weight

MCW509AMUA 265 31, 36 10.8 x 30.9 x 7.3 17.6MCW512AMUA 310 31, 39 10.8 x 30.9 x 7.3 17.6MCW518AMUA 520 36, 43 11.8 x 41.3 x 7.5 26.4MCW524AMUA 525 38, 46 11.8 x 41.3 x 7.5 26.4MCW530AMUA 600 37, 41 14.2 x 61.8 x 7.9 59.5MCW536AMUA 800 41, 45 14.2 x 66.5 x 7.9 61.7

Table MINI-1-B – Accessories – Remote Controller Options (MCW530 & MCW536)11111

Model Number Description H W D

RAYSTAT020A ............ Wired Remote Controller ............... 4.8 ......... 4.8 ......... 0.7RAYSTAT021A ............ Wireless Remote Controller ........... 6.2 ......... 2.4 ......... 0.7

Table MINI-1-C – Accessories – Expansion Device (Orifice) (All Sizes)11111

Model Model UsedNumber Description With Size

BAYOFKT001 .... Metering Device (Orifice) ..... MCW512-18 ..... .043/.046BAYOFKT002 .... Metering Device (Orifice) ....... MCW524 ............ .047BAYOFKT003 .... Metering Device (Orifice) ....... MCW530 ............ .057BAYOFKT004 .... Metering Device (Orifice) ....... MCW536 ............ .063

Table MINI-1-D – Accessories – Low Voltage Transformer (All Sizes)11111

Model Model UsedNumber Description With

BAYHVLV001 ...... 208-240/24V Transformer ............ All1 Required for unit operation with TTB, 2TTB2 condensing units. Not required with TTK condensing units.

Ductless Air Conditioners

• Low sound levels through improved fanand motor.

• Precise Airflow through unique wide airdiffusion system.

• Three stage air filter for improved IndoorAir Quality (IAQ).

• Flexibility to be matched with 10 SEERand 12 SEER condensing units.

• Washable Grille.• Lightweight and compact size.• Powerful mode for 20 minute maxi-

mum output.• Cooling, Dehumidify (Dry), and Fan-

Only modes

Page 286: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

MINI-2Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Table MINI-2-A – Ductless Outdoor Unit - Cooling OnlyNom. Cap. Uncrated Line Size

Model Power Cooling Dimensions(in.) Shipping Sound Max OD ODNumber Supply (BTUH) H W D Weight Rating MCA* Fuse* Gas Liq.TTK509E5UA 208-230/1/60 9,000 20 28 10 66 53 6.6 10 3/8 1/4TTK512E5UA 208-230/1/60 12,000 20 28 10 77 53 7.3 12 1/2 1/4TTK518E5UA 208-230/1/60 18,000 29 33 13 121 58 11.7 20 1/2 1/4TTK524E5UA 208-230/1/60 24,000 29 33 13 141 62 14.5 25 5/8 1/4TTK530E5UA 208-230/1/60 30,000 29 33 13 163 62 21.5 35 5/8 3/8TTK536E5UA 208-230/1/60 36,000 29 33 13 168 64 26 45 3/4 3/8

Table MINI-2-B – Optional Accessories:Model Model UsedNumber Description With

BAYLOAMM001A Low Ambient Kit TTK509-512

BAYLOAMM002A Low Ambient Kit TTK518-536

• 9000 Btu model available• Low sound levels• Reduced installation time

• 10-12 SEER depending uponcapacity

• Installation flexibility

Ductless Outdoor Units

Page 287: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PTAC/UH-1 Effective 1/1/06

Table PTAC/UH-1-A — Packaged Terminal Air ConditionerPower Supply Cooling Cabinet Shipping

Chassis Volts/Phase/Hz Capacity EER kW H x W x D WeightPTED0701D*A 208-230/1/60 7,000 12.5 2.0 16 1/6 x 42 x 13 ¾ 102PTED0701G*A 208-230/1/60 7,000 12.5 3.5 16 1/6 x 42 x 13 ¾ 102PTED0701W*A5 208-230/1/ 60 7,000 12.5 N/A 16 1/6 x 42 x 13 ¾ 102PTED0901D*A 208-230/1/ 60 9,000 11.6 2.0 16 1/6 x 42 x 13 ¾ 103PTED0901G*A 208-230/1/ 60 9,000 11.6 3.5 16 1/6 x 42 x 13 ¾ 103PTED0901W*A5 208-230/1/ 60 9,000 11.5 N/A 16 1/6 x 42 x 13 ¾ 103PTED0902D*A 265/1/60 9,000 11.5 2.0 16 1/6 x 42 x 13 ¾ 103PTED0902G*A 265/1/60 9,000 11.5 3.7 16 1/6 x 42 x 13 ¾ 103PTED1201G*A 208-230/1/60 12,000 11.2 3.5 16 1/6 x 42 x 13 ¾ 109PTED1201J*A 208-230/1/60 12,000 11.2 5.0 16 1/6 x 42 x 13 ¾ 109PTED1201W*A5 208-230/1/60 12,000 11.2 N/A 16 1/6 x 42 x 13 ¾ 109PTED1202G*A 265/1/60 12,000 11.2 3.7 16 1/6 x 42 x 13 ¾ 110PTED1501G*A 208-230/1/60 15,000 10.2 3.5 16 1/6 x 42 x 13 ¾ 117PTED1501J*A 208-230/1/60 15,000 10.2 5.0 16 1/6 x 42 x 13 ¾ 117PTED1501W*A5 208-230/1/60 15,000 10.2 N/A 16 1/6 x 42 x 13 ¾ 117PTED1502G*A 265/1/60 15,000 10.0 3.7 16 1/6 x 42 x 13 ¾ 118

Table PTAC/UH-1-B — Packaged Terminal Heat Pump with Electric HeatPower Supply Cooling Cabinet Shipping

Chassis Volts/Phase/Hz Capacity EER kW H x W x D WeightPTHD0701D*A 208-230/1/60 7,000 12.2 2.0 16 1/6 x 42 x 13 ¾ 102PTHD0701G*A 208-230/1/60 7,000 12.2 3.5 16 1/6 x 42 x 13 ¾ 102PTHD0901D*A 208-230/1/60 9,000 11.2 2.0 16 1/6 x 42 x 13 ¾ 109PTHD0901G*A 208-230/1/60 9,000 11.2 3.5 16 1/6 x 42 x 13 ¾ 109PTHD0902D*A 265/1/60 9,000 11.2 2.0 16 1/6 x 42 x 13 ¾ 109PTHD0902G*A 265/1/60 9,000 11.2 3.7 16 1/6 x 42 x 13 ¾ 109PTHD1201G*A 208-230/1/60 12,000 10.3 3.5 16 1/6 x 42 x 13 ¾ 110PTHD1201J*A 208-230/1/60 12,000 10.3 5.0 16 1/6 x 42 x 13 ¾ 110PTHD1202G*A 265/1/60 12,000 10.7 3.7 16 1/6 x 42 x 13 ¾ 110PTHD1501G*A 208-230/1/60 15,000 9.7 3.5 16 1/6 x 42 x 13 ¾ 110PTHD1501J*A 208-230/1/60 15,000 9.7 5.0 16 1/6 x 42 x 13 ¾ 118PTHD1502G*A 265/1/60 15,000 9.3 3.7 16 1/6 x 42 x 13 ¾ 118Notes:1 All units ship with cord and plug.2 265 volt units require either a subbase or a hard wire junction box kit to be U.L. approved.3 All units are ARI listed, C.U.L. and U.L. approved.4 All units include a cord with plug, unit mounted control, built in front desk control terminals (wiring kit is required) temperature

limiter, room freeze protection, fan cycle switch, compressor time delay, cooling condensate removal and automatic emergencyheat stage thermostat on all heat pumps. Also all units have a built-in switch to change operation from unit mounted control toremote, wall, mounted control.

5 Hydronic units ship with no electric heat and no plastic front cover. The hydronic kit, which must be ordered separately, includes ametal front cover.

Packaged TerminalAir Conditioners And Heat Pumps

Page 288: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PTAC/UH-2Effective 1/1/06

Table PTAC/UH-2-A — AccessoriesDescription and Usage Sleeves Order NumberStandard Wall Sleeve WS130

Extended 18" Wall Sleeve WS180

Extended 24" Wall Sleeve WS240

Note: To be ordered for all installations except where existing wall sleeves are used.Drain Kit DRAIN

Note: Attaches to wall sleeve for controlled indoor or outdoor disposal of condensate to a field supplied drain system.

GrillesStamped Aluminum Grille - Single Pack SAG01Stamped Aluminum Grilles - Ten Pack SAG10Architectural Aluminum Grille - Anodized finish AAGALArchitectural Aluminum Grille - Dark Bronze AAGDBArchitectural Aluminum Grille - Soft Dove AAGSDWall Sleeve Levelling Legs LVLG02

Note: Used when a subbase is not required, but, additional support and leveling is needed. The adjusting screw can be extended 2 inches with a maximumdistance from the bottom of the wall sleeve to screw base of 5 inches and a minimum distance of 3 inches.

SubbasesSubbase 230/208V, 20A SUB0120Subbase 230/208V, 30A SUB0130Subbase 265V, 20A SUB0220Subbase 265V, 30A SUB0230

Note: Provides a space to tie into building wiring and also includes a receptacle to plug unit into. Gives additional leveling and support capabilities. Provides aplace for fuses, circuit breaker or mechanical disconnect to be mounted.

Power or Mechanical Disconnect SwitchPower Switch 230/208V, 30 A PS0130Power Switch 265V, 30 A PS0230

Note: These above kits can be installed on hard wire junction box and provides a way to shut unit on and off. Check local codes for approval.

Circuit Breaker KitsCircuit Breaker 15A CB0115Circuit Breaker 20A CB0120Circuit Breaker 30A CB0130

Note: The Circuit Breaker Kit can be installed on front of subbase and provides overcurrent protection and means of shutting unit on and off.Control Panel Key Lock KEYLOK

Note: To prevent unauthorized access to unit control panel.

Fuse Holder KitsFuse Holder Kit 15A FUSE0115Fuse Holder Kit 20A FUSE0120Fuse Holder Kit 30A FUSE0130

Note: Cartridge fuse fits into receptacle with screw type cap. Installed at unit control panel or in subbase. Provides overcurrent protection.Hard Wire Kit HWIREK

Note: This kit provides convenient space to make electrical connection to building wiring. Includes flexible conduit, and wire to make connection from unitchassis.

Hydronic Chassis OptionPlastic Front Cover PFC01

Note: Use with hydronic chassis when hot water kit is not used.

Packaged TerminalAir Conditioners And Heat Pumps

Page 289: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PTAC/UH-3 Effective 1/1/06

Table PTAC/UH-3-A — AccessoriesHydronic Kits Order NumberHydronic Steam Heat Kit - 230/208V HSK01Hydronic Steam Heat Kit - 265V HSK02Hydronic Steam Heat Kit - 115V HSK04Hydronic Water Heat Kit - 115V HWK04Hydronic Water Heat Kit - 265V HWK02Hydronic Water Heat Kit - 230/208V HWK01

Note: Hydronic kits are to be ordered with the hydronic heat chassis only. Kits come with valve and transformer.Note: All valves for Hydronic and Steam are 24 volt and include an end switch.

Digital Wall Mounted Thermostats1H/1C Digital Prog Tstat (4-wire Pwr Steal) TAYSTAT3401H/1C Digital NonProg Tstat (4-wire Pwr Steal) TAYSTAT3712H/1C Heat Pump Digital Prog Tstat TAYSTAT5402H/1C Heat Pump Digital NonProg Tstat TAYSTAT570

Note: All Wall Mounted Thermostats will work with standard units. All units include a switch for changing from unit mounted operation to remote or wallmounted operation. See notes for AUXWIRE.

Wire Harness Kit - 10 Pack AUXWIRENote: Required when Wall Mounted Thermostat or Zone Sensor is used.

Remote Zone Sensor ZONSENSNote: This temperature sensor overrides standard unit mounted thermostat to allow temperature sensing on internal wall for more accurate temperaturecontrol.

Remote Escutcheon Kits - 10 Pack REK10CNote: This kit should be ordered whenever Wall Thermostats are ordered. This Kit includes a control cover plate, that will cover the normal unit mountednomenclature. This kit comes 10/pack. A wire harness kit should be ordered separate.

Condensate PumpsCondensate Pump 230/208V CDP01Condensate Pump 265V CDP02

Note: This kit is for Heat Pumps ONLY and includes a small pump that will remove condensate developed during the heat pump operation and transfer it tothe indoor coil for re-evaporation and to dissipate into the room, adding humidity to the room. This option cannot be used with Corrosion-Resistant Models.This can be field installed but it is very time-consuming and it is our recommendation that you choose the factory installed option. Important, even with thisoption if no overflow of condensate is permissible, the installation of an external or building internal drain system is recommended.

Spare Filters - 10 Pack FILTR10Note: Using the field installed, permanent, cleanable filters will keep debris off of the coil and out of the air. Unit will operate more efficiently if filters arechanged regularly.

Packaged TerminalAir Conditioners And Heat Pumps

Page 290: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PTAC/UH-4Effective 1/1/06

Indoor Gas Heating ProductsProduct Description Indoor Units

Propeller Fan Gas Unit Heater

• Two-point Suspension• Horizontal Louvers• 115/60/1 Open Drip-proof Motor with

Built-in T.O.P.• 24V Control Transformer• Junction Box for Power Wiring• Single-Stage Automatic Gas Valve• Standing Pilot• Fan Time Delay Relay• Aluminized Steel Heat Exchanger• Blocked Vent (Spill) Switch

• “10 Year Non-Prorated Warranty” onthe Heat Exchanger, Burners andDraft Hood Assembly.

High Efficiency Propeller Fan GasUnit Heater

• Two-point Suspension• Horizontal Louvers• 115/60/1 Open Drip-proof Motor with

Built-in T.O.P.• 24V Control Transformer• Junction Box for Power Wiring• Single-Stage Combination Gas Valve• Intermittent Pilot Ignition• Fan Time Delay Relay• Aluminized Steel Heat Exchanger• Factory Installed Flue Vent Fan• Combustion Air Pressure Switch

• “10 Year Non-Prorated Warranty” onthe Heat Exchanger, Burners andDraft Hood Assembly.

Centrifugal Fan Gas Unit Heater

• Horizontal Louvers• 115/60/1 Open Drip-proof Motor with

Built-in T.O.P.• Adjustable V-belt Drive With Belt Guard• 24V Control Transformer• Junction Box for Power Wiring• Single-Stage Automatic Gas Valve• Standing Pilot• Fan Time Delay Relay• Aluminized Steel Heat Exchanger• Blocked Vent (Spill) Switch

• “10 Year Non-Prorated Warranty” onthe Heat Exchanger, Burners andDraft Hood Assembly.

The State of California requires a steady-state efficiency of 80% forboth indoor and outdoor gas heating equipment. All units shippingto the state of California require intermittent pilot ignition.

Contact Macon Product Support for moreinformation on these products (1-800-322-6495)

Page 291: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PTAC/UH-5 Effective 1/1/06

Indoor Gas Heating ProductsProduct Description Indoor Units

High Efficiency Centrifugal Fan GasUnit Heater

• Horizontal Louvers• 115/60/1 Open Drip-proof Motor with

Built-in T.O.P.• Fan Guard• 24V Control Transformer• Junction Box for Power Wiring• Single-Stage Intermittent Pilot Ignition• Fan Time Delay Relay• Aluminized Steel Heat Exchanger

• Factory Installed Flue Vent Fan• Combustion Air Pressure Switch• “10 Year Non-Prorated Warranty”

on the Heat Exchanger, Burnersand Draft Hood Assembly.

Indoor Gas Duct Furnace

• Blow Through Applications Only!• 24V Control Transformer• Junction Box For Power Wiring• Single-Stage Automatic Gas Valve• Standing Pilot• Aluminized Steel Heat Exchanger• 10 year warranty “does not apply.”

Trane’s standard 12/18 month only.• Blocked Vent (Spill) Switch

Note: A drain pan is not included.See field installed options.

High Efficiency Indoor Gas DuctFurnace

• Blow Through Applications Only• 24V Control Transformer• Junction Box For Power Wiring• Single-Stage Combination Gas Valve• Intermittent Pilot Ignition• Aluminized Steel Heat Exchanger• Factory Installed Flue Vent Fan• Combustion Air Pressure Switch• 10 year warranty “does not apply.”

Trane’s standard 12/18 month only.

Note: A drain pan is not included.See field installed options.

Horizontal Blower Assembly

• Junction Box For Power Wiring• Filter Rack and 1” Permanent Filters• Adjustable V-Belt Drive• 10 year warranty “does not apply.”

Trane’s standard 12/18 month only.

The State of California requires a steady-state efficiency of 80% forboth indoor and outdoor gas heating equipment. All units shippingto the state of California require intermittent pilot ignition.

Contact Macon Product Support for moreinformation on these products (1-800-322-6495)

Page 292: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PTAC/UH-6Effective 1/1/06

Indoor Gas Heating ProductsIndoor Units

Table PTAC/UH-6-A — Propeller Fan Gas Unit HeatersUnit Size 003 004 006 007 010 012 015 017 020 022 025 030 035 040MBh (input) 30 45 60 75 100 125 150 175 200 225 250 300 350 400MBh (output) 24.3 36.5 48.6 60.8 80.0 100.0 120.0 140.0 160.0 180.0 200.0 240.0 280.0 320.0

Propeller Fan AlumUnit Heater 409SSGPND or GPPD 321SS — — — —Std. 115/60/1 motor hp 1/30 1/30 1/30 1/30 1/20 1/10 1/4 1/3 1/3 1/3 1/3 (2)1/4 (2)1/3 (2)1/3Notes:Approved in California when ordered with intermittent pilot ignition.

Table PTAC/UH-6-B — High Efficiency Propeller Fan Unit HeaterUnit Size 003 004 006 007 010 012 015 017 020 022 025 030 035 040MBh (input) 30 45 60 75 100 125 150 175 200 225 250 300 350 400MBh (output) 24.9 37.4 48.0 60.0 80.0 100.0 120.0 140.0 160.0 180.0 200.0 240.0 280.0 320.0

High Eff Prop AlumFan U.H. 409SSGHND or GHPD 321SS — — — —Std 115/60/1 motor hp 1/30 1/30 1/30 1/30 1/20 1/10 1/4 1/3 1/3 1/3 1/3 (2)1/4 (2)1/3 (2)1/3Notes:1. The only gas control option available is single stage intermittent pilot. This is included in the list price of the unit.2. 115V flue vent fans are factory installed and included in the list price of the unit.

Table PTAC/UH-6-C — Separated Combustion Propeller Fan Gas Unit HeaterUnit Size 010 012 015 017 020 022 025 030 035 040MBh (input) 100 125 150 175 200 225 250 300 350 400MBh (output) 80.0 100.0 120.0 140.0 160.0 180.0 200.0 240.0 280.0 320.0

Sep. Comb. AlumFan U.H. 409SSGAND or GAPD 321SSStd 115/60/1 motor hp 1/20 1/10 1/4 1/3 1/3 1/3 1/3 (2) 1/4 (2) 1/3 (2) 1/3Notes:1. Single stage intermittent pilot ignition is standard and included in the list price of the unit. Two-stage intermittent pilot is available as an option.2. 115V factory installed flue vent fan is included in the list price of the unit.

Table PTAC/UH-6-D — Centrifugal Fan Gas Unit HeatersUnit Size 010 012 015 017 020 022 025 030 035 040MBh (input) 100 125 150 175 200 225 250 300 350 400MBh (output) 80.0 100.0 120.0 140.0 160.0 180.0 200.0 240.0 280.0 320.0

Centrifugal Fan Alum Unit Heater 409SS GCND or GCPD 321SS Std 115/60/1 motor hp 1/4 1/3 1/2 1/2 3/4 3/4 3/4 3/4 1 1Notes:1. Includes standard 115/60/1 open drip-proof motor.2. If other than standard voltage required, deduct standard motor and add required motor.3. Contact Macon Product Support if motor size other than standard size is required.4. Approved in California when ordered with intermittent pilot ignition.5. If ordering a flue vent fan (460V units) add transformer list add shown in flue vent fan table.

The State of California requires a steady-state efficiency of 80% forboth indoor and outdoor gas heating equipment. All units shippingto the state of California require intermittent pilot ignition.

Contact Macon Product Support for moreinformation on these products (1-800-322-6495)

Page 293: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PTAC/UH-7 Effective 1/1/06

Table PTAC/UH-7-A — High Efficiency Centrifugal Fan Gas Unit HeaterUnit Size 010 012 015 017 020 022 025 030 035 040MBh (input) 100 125 150 175 200 225 250 300 350 400MBh (output) 80.0 100.0 120.0 140.0 160.0 180.0 200.0 240.0 280.0 320.0

High Eff. Cent. AlumFan U.H. 409SSGBND or GBPD 321SSSt. 115/60/1 motor hp 1/4 1/3 1/2 1/2 3/4 3/4 3/4 3/4 1 1Notes:1. Includes standard 115/60/1 open drip-proof motor.2. If other than standard voltage is required, deduct standard motor and add required motor.3. 115V flue vent fans are standard and included. If other than standard voltage is required, include a Line/115V transformer.4. Contact Macon Product Support, if motor size other than standard is required.

Table PTAC/UH-7-B — Separated Combustion Centrifugal Fan Gas Unit HeaterUnit Size 010 012 015 017 020 022 025 030 035 040MBh (input) 100 125 150 175 200 225 250 300 350 400MBh (output) 80.0 100.0 120.0 140.0 160.0 180.0 200.0 240.0 280.0 320.0

Sep. Comb. Cent. AlumFan U.H. 409SSGKND or GKPD 321SSStd 115/60/1 motor hp 1/4 1/3 1/2 1/2 3/4 3/4 3/4 3/4 1 1Notes:1. Includes standard 115/60/1 open drip-proof (ODP) motor.2. If other than standard voltage is required, deduct standard motor and add required motor.3. Includes single-stage intermittent pilot ignition and a 115V factory installed flue vent fan. If other than standard voltage is required, include a line/115V transformer.4. Two-stage intermittent pilot ignition is available as an option.5. Contact Macon Product Support if motor size other than standard is required.

Table PTAC/UH-7-C — Indoor Gas Duct FurnacesUnit Size 010 012 015 017 020 022 025 030 035 040MBh (input) 100 125 150 175 200 225 250 300 350 400MBh (output) 80.0 100.0 120.0 140.0 160.0 180.0 200.0 240.0 280.0 320.0

Indoor Duct AlumFurnace 409SSGDND or GDPD 321SSNotes:Duct Furnaces are approved only in blow-thru applications.If a duct furnace is being used with an HBAC — the main power supply must be the same. The duct furnace includes a Line to 24V control transformer.

Table PTAC/UH-7-D — High Efficiency Gas Duct FurnacesUnit Size 010 012 015 017 020 022 025 030 035 040MBh (input) 100 125 150 175 200 225 250 300 350 400MBh (output) 80 100 120 140 160 180 200 240 280 320

High Eff Indoor AlumDuct Furnace 409SSGLND or GLPD 321SSNotes:1. Includes single-stage intermittent pilot.2. Includes 115/24V control transformer. No other voltage selection available.3. 115V flue vent fans are factory installed.4. Approved in the blow-thru applications only.

Indoor Gas Heating ProductsIndoor Units

The State of California requires a steady-state efficiency of 80% forboth indoor and outdoor gas heating equipment. All units shippingto the state of California require intermittent pilot ignition.

Contact Macon Product Support for moreinformation on these products (1-800-322-6495)

Page 294: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PTAC/UH-8Effective 1/1/06

Indoor Gas Heating ProductsIndoor Units

Table PTAC/UH-8-A — Separated Combustion Duct FurnacesUnit Size 010 012 015 017 020 022 025 030 035 040MBh (input) 100 125 150 175 200 225 250 300 350 400MBh (output) 80.0 100.0 120.0 140.0 160.0 180.0 200.0 240.0 260.0 320.0

Sep. Comb. AlumDuct Furnace 409SSGMND or GMPD 321SSNotes:1. Includes single-stage intermittent pilot.2. Includes 115/24V control transformer. No other voltage selection available.3. 115V flue vent fans are factory installed.4. Approved in the blow-through applications only.

Table PTAC/UH-8-B— Tubular Heat Exchanger, Propeller Gas Unit HeaterUnit Size 003 004 006 007 009 010 012 015 017 020 025 030 035 040

MBh (input) 30 45 60 75 90 100 125 150 175 200 250 300 350 400MBh (output) 24.3 36.5 48.6 60.8 72.9 81.0 101.3 121.5 141.7 162.0 202.5 243.0 283.5 324.0

Tubular Heat Exc. AlumGTND or GTPDStd. 115/60/ motor hp 1/20 1/20 1/20 1/20 1/20 1/10 1/4 1/4 1/3 1/3 1/3 1/4 1/3 1/3Notes:1. Units only available with Aluminized Heat Exchanger, stainless steel not available or required.2. Factory installed flue vent fan is included.3. The gas control is single stage, hot surface pilot ignition and is included in the unit.4. Size 225 MBh units are not available.

Table PTAC/UH-8-C — Tubular Heat Exchanger - Residential Propeller Fan Gas Unit HeaterUnit Size R03 R04 R06 R07 R09MBh (input) 30 45 60 75 90MBh (output) 24.3 36.5 48.6 60.8 72.9

Tubular - Residential AlumGTND or GTPDStd. 115/60/1 motor hp 1/20 1/20 1/20 1/20 1/20Notes:1. Includes standard 115/60/1 open drip-proof (ODP) motor. If totally enclosed 115/60/1 motors are required.2. Units only available with Aluminized Heat Exchanger, stainless steel not available or required.3. Factory installed flue vent fan is included.4. The only gas control option available is single stage, hot surface pilot ignition. This is included in the unit.5. Includes spil or flame roll out switch.6. Includes OSHA Fan Guard.

Table PTAC/UH-8-D — Horizontal Blower AssemblyHorizontal Unit Size 15 20 030 045Blower Duct Furnace Size Used With 010, 012 015, 017 020, 022, 025 030, 035, 040Assembly Unit —HBAC Transition 48 48 48 48Note:Does not include motor. Motor from Table PTAC/UH-9-A must be added to unit.

The State of California requires a steady-state efficiency of 80% forboth indoor and outdoor gas heating equipment. All units shippingto the state of California require intermittent pilot ignition.

Contact Macon Product Support for moreinformation on these products (1-800-322-6495)

Page 295: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PTAC/UH-9 Effective 1/1/06

Table PTAC/UH-9-A —Motor Prices Voltage 1/4 hp 1/3 hp 1/2 hp 3/4 hp 1 hp 1-1/2 hp 2 hp 115/60/1 - Open 230/60/1 - Open 208/60/3 - Open — 230/60/3 - Open — 460/60/3 - Open — 575/60/3 - Open — — 115/60/1 - T.E. 230/60/1 - T.E. 208/60/3 - T.E. — 230/60/3 - T.E. — 460/60/3 - T.E. — 575/60/3 - T.E. — — Shipping Wt. 51 55 55 57 57 75 88

motor prices — for totally enclosed motors for Propeller Fan Unit Heaters only and Tubular Units Voltage 1/3 hp 1/20 hp 1/10 hp 1/4 hp 1/3 hp 1/4 hp 1/3 hp Unit sizes 003 004 006 007 10 12 15 017 020 022 025 30 035 040

R03, R04, R06, R07, R09 115/60/1 Note:Contactors not required on any units provided with single phase motors up to 1 hp. Low voltage contactors are included on all units with single phase 11/2 hp and above motors andon all three-phase motors.

Table PTAC/UH-9-B —Gas Control OptionsPilot — Gas Type Control Designator

Standard Standing Pilot — Single-Stage A**Propeller, Duct and Natural or LP (Propane) Gas Hydraulic Modulating1 CCentrifugal Units Only Intermittent Pilot — Single-Stage D (GP, GC, GD) Natural or LP (Propane) Two-Stage4 E Gas Hydraulic Modulating1,4 F Hydraulic Modulating w/Bypass1,4 G

Intermittent — Pilot — Electronic Modulating — Room Stat HNatural or LP (Propane) Gas Electronic Modulating — Duct Stat5 J

Electronic Modulating w/External L4-20 mA InputElectronic Modulating w/External N0-10 VDC Input

High Efficiency Intermittent Pilot Single-Stage D**Units — Propeller, Natural or LP (Propane) Gas Two-Stage4 ECentrifugal and Duct Hydraulic Modulating1,4 F Furnaces Only Hydraulic Modulating w/Bypass1,4 G (GH, GB, GL) Intermittent Pilot — Electronic Modulating — Room Stat4 H

Natural or LP (Propane) Gas Electronic Modulating — Duct Stat4, 5 JElectronic Modulating w/External L4-20 mA InputElectronic Modulating w/External N0-10 VDC Input

Separated Intermittent Pilot — Single-Stage DCombustion Units Natural or LP (Propane) Two-Stage E

Intermittent Pilot — Electronic Modulating — Room Stat4 HNatural or LP (Propane) Gas Electronic Modulating — Duct Stat4, 5 J

Electronic Modulating w/External L4-20 mA InputElectronic Modulating w/External N0-10 VDC Input

Tubular Heat Exchanger Units Hot surface pilot ignition Single-Stage KTubular Heat Exchanger Units Hot surface pilot ignition Two-Stage ENotes:1. Specify discharge temperature in the body of the order. Two hydraulic modulating valves are offered. One valve has a range of 60-100 degrees. The other valve has a range of

75-200°. If no temperature is specified, the 60-100 range will ship. N/A on sizes 003-007.2. For elevations over 4000 ft., hydraulic modulating is not available.3. Units for California shipment require intermittent pilot ignition.4. Not available on sizes 003-007. These sizes are AGA approved on single stage gas controls only. Two-stage control is available up to 7,500 ft. elevation. Over 7500 ft., single

stage only.5. Only available on duct unit heaters or centrifugal with duct discharge flange option.** Not available.

Indoor Gas Heating ProductsIndoor Unit Options(Factory Installed)

The State of California requires a steady-state efficiency of 80% forboth indoor and outdoor gas heating equipment. All units shippingto the state of California require intermittent pilot ignition.

Contact Macon Product Support for moreinformation on these products (1-800-322-6495)

Page 296: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PTAC/UH-10Effective 1/1/06

Table PTAC/UH-10-A — Miscellaneous Options Available On Option Designator All Gas Special Orifices B** Heating Units3 Summer-Winter Switch* D Centrifugal Fan Unit Heaters Duct Discharge Flange1 H** Indoor Duct Fan Time Delay Control L Furnaces Side Access Burner Drawer2 K Horiz. Blower Assembly Motor 3 See Table PTAC/UH-9-ANotes:* When used with a duct furnace, optional fan time delay control must be ordered.1. Not required when nozzles are ordered.2. Standard side access is on the left side as the airflow is blowing in your face. Opposite from standard can be ordered as a special. Contact Macon Product Support.3. Not available on Tubular Heat Exchanger units.** Not available.

Indoor Gas Heating ProductsIndoor Unit Options(Factory Installed)

The State of California requires a steady-state efficiency of 80% forboth indoor and outdoor gas heating equipment. All units shippingto the state of California require intermittent pilot ignition.

Contact Macon Product Support for moreinformation on these products (1-800-322-6495)

Page 297: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PTAC/UH-11 Effective 1/1/06

Table PTAC/UH-11-A— Miscellaneous OptionsUnit Size 003 004 006 007 010 012 015 017 020 022 025 030 035 040

MBhAvailable On Option Des 30 45 60 75 100 125 150 175 200 225 250 300 350 400

409 S.S. Burners A — — — —

All Units1 409 S.S. Flue Collector/Draft Diverter C — — — —Vertical Louvers E — — — —Horiz. Louvers F — — — —

Indoor Horiz. & VerticalDuct Furnaces Louvers G — — — —

Unit Size 32 42 62 94Horiz. Blower Insul. for BlowerAssembly & Transition 1Available on Unit Size 003 004 006 007 010 012 015 017 020 022 025 030 035 040Propeller Fan, MBhHigh Efficiency Option Des 30 45 60 75 100 125 150 175 200 225 250 300 350 400Propeller Fan OSHA Fan Guards 7and TubularHeat ExchangerSeparated OSHA Fan Guards 7 — — — —

CombustionPropeller Fan UnitsNote:1. 409 S.S. Burners, 409 S.S. Flue Collector/Draft Diverter and Vertical Louvers are not available on Tubular Heat exchanger units.

Indoor Gas Heating ProductsIndoor Unit Accessories(Factory Installed)

The State of California requires a steady-state efficiency of 80% forboth indoor and outdoor gas heating equipment. All units shippingto the state of California require intermittent pilot ignition.

Contact Macon Product Support for moreinformation on these products (1-800-322-6495)

Page 298: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PTAC/UH-12Effective 1/1/06

Table PTAC/UH-12-A—Flue Vent FansFlue Vent Fan Thermostat4 Unit 003 004 006 007 010 012 015 017 020 022 025 030 035 040Power Supply Size 30 45 60 75 100 125 150 175 200 225 250 300 350 400115/60/1 Ordering No

Low 350-0019- 01 02 04 05 06 07 08 09 10 11 12 13 14 151 List Price208/60/1 Order No

Low 350-0019- — — — 17 18 19 20 21 22 23 24 25 26 272 List Price230/60/1 Order No

Low 350-0019- — — — 29 30 31 32 33 34 35 36 37 38 393 List PriceNotes:All flue vent fans provided with adaptor for unit mounting.1. For use with units with 115/60/1 main power supply.2. For use with units with 208/60/1 or 208/60/3 main power supply.3. For use with units with 230/60/1, 230/60/3, 460/60/3, or 575/60/3 main power supply. Order should specify when for use with units with 460/60/3 or 575/60/3 main power supply, a

460/230V transformer is required.4. Flue vent fans for use with low voltage thermostats are provided with a relay with 24V holding coil.5. Flue vent fans are standard 115V on GHPD, GHND, GBPD, GBND, GLND, GLPD, GAND, GAPD, GKND, GKPD, GMND, GMPD, GTND,GTPD units and included in the unit. Do not

order separately.

Table PTAC/UH-12-B—Miscellaneous AccessoriesAvailable On Option Pipe Size Order No 350-Natural Gas High Gas LineHeating Units Pressure Regulator (See Note) 3/4” NPT 0015-20Notes:When high gas line pressure regulators are ordered you must specify the pressure at the job. This is required so the factory can select the regulator to accommodate thespecific pressure at the job. More than one unit can be run from one regulator, however, we recommend that each unit have its own regulator. See orifice chart thatfollows. N/A requires local purchase of regulator.When ordered separate, must include model and size of unit.

Orifice Chart: Rockwell 043-182 RegulatorInlet Capacity in MBh for Natural Gas Spring

Pressure 25-200 225-300 350-500 600 700 800 Required1 psi 3/8” — — — — — Blue (only)

2 3/8” 3/8” — — — — Blue (only)3 3/8” 3/8” 3/8” — — — Blue or Green5 3/8” 3/8” 3/8” 3/8” 3/8” 3/8” Blue or Green

10 3/8” 3/8” 3/8” 3/8” 3/8” 3/8” Blue or Green20 1/4” 1/4” 1/4” 1/4” 1/4” 5/16” Blue or Green40 1/4” 1/4” 1/4” 1/4” 1/4” 1/4” Blue or Green60 1/8” 1/8” 1/8” 1/8” 1/8” 3/16” Blue or Green80 1/8” 1/8” 1/8” 1/8” 1/8” — Blue or Green

100 1/8” 1/8” 1/8” 1/8” 1/8” 1/8” Blue or Green125 1/8” 1/8” 1/8” 1/8” 1/8” 1/8” Blue or Green

Indoor Gas Heating ProductsIndoor Unit Accessories(Field Installed)

The State of California requires a steady-state efficiency of 80% forboth indoor and outdoor gas heating equipment. All units shippingto the state of California require intermittent pilot ignition.

Contact Macon Product Support for moreinformation on these products (1-800-322-6495)

Page 299: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PTAC/UH-13 Effective 1/1/06

Table PTAC/UH-13-A—Miscellaneous AccessoriesUnit Size 010 012 015 017 020 022 025 030 035 040

Available On Option Unit MBh 100 125 150 175 200 225 250 300 350 400All Units 6 Y Splitter Ordering No

Discharge 350-0018- 03 04 05 06 07 08 09 10 11 12 Nozzle1 List Price 90° Downward Ordering No Discharge 350-0018- 27 28 29 30 31 32 33 34 35 36 Nozzle1,4 List Price 30° Downward Ordering No Discharge 350-0018 65 45 46 47 48 49 50 51 52 53 Nozzle 1,4 List Price 60° Downward Ordering No Discharge 350-0018 68 54 55 56 57 58 59 60 61 62 Nozzle 1,4 List Price

Ordering No Only Drain Pan5 350-0076- 03 04 05 06 07 08 09 10 11 12 Indoor (Al Steel) List Price Duct Furnaces, & Ordering No Hi Eff. Drain Pan5 350-0076- 15 16 17 18 19 20 21 22 23 24 not Sep. Comb. (409 SS) List Price

Unit Size 15 20 30 45 Horiz. Blower Ordering No Assembly 1” TA Filter 350-0050- 01 01 03 05 Set List Price 1” Perm Filter Ordering No

Set 350-0050- 02 02 04 06 (Std on HBAC) List Price

Unit Size 003 004 006 007 010 012 015 017 020 022 025 030 035 040Option Unit MBh 30 45 60 75 100 125 150 175 200 225 250 300 350 400

Available on OSHA Ordering NoPropeller Fan, Fan 350-0154- 01 01 02 02 02 02 02 04 04 04 04 03 05 05High Efficiency Guards List Price Propeller Fan andTubular HeatExchanger UnitsSeparated OSHA Ordering No.Combustion Fan 350-0154- — — — — 02 02 02 04 04 04 04 03 05 05Propeller Fan Units Guards List PriceNotes:1. Available on all indoor units 100-400 MBh.2. Only available on Duct Furnaces and Centrifugal Fan Unit Heaters.3. When nozzles are ordered separate from the unit, specify unit type. High efficiency units have different nozzle configurations than standard units.4. 60° nozzles are two 30° and 90° nozzles are three 30° nozzles. All nozzles ship unassembled.5. Recommended when used downstream of a cooling coil.6. If unit has (E) vertical louvers and nozzles are ordered, vertical louvers not needed because vertical louvers are on nozzles.

Indoor Gas Heating ProductsIndoor Unit Accessories(Factory Installed)

The State of California requires a steady-state efficiency of 80% forboth indoor and outdoor gas heating equipment. All units shippingto the state of California require intermittent pilot ignition.

Contact Macon Product Support for moreinformation on these products (1-800-322-6495)

Page 300: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PTAC/UH-14Effective 1/1/06

Table PTAC/UH-14-A— Vent Caps and Adapters (Reducers or Increasers)Unit Size 003 004 006 007 010 012 015 017 020 022 025 030 035 040

Available on all Option Unit MBh 30 45 60 75 100 125 150 175 200 225 250 300 350 400

High Efficiency and 4” Ordering NoSeparated Vent Cap 0350-0155- 01 01 01 01 01 01 01 01 — — — — — —Combustion Units

and Tubular Heat 5” Ordering NoExchanger Units Vent Cap 0350-0157- — — — — — — — — 01 01 01 — — —

6” Ordering NoVent Cap 0350-0158- — — — — — — — — — — — 01 01 01

5” to 4” Ordering NoReducer 0350-0156- 01 01 01 01 01 01 01 01 — — — — — —

5 to 6” Ordering NoIncreaser 0350-0159- — — — — — — — — — — — 01 01 01

Notes:1. These are mandatory, for the Canadian market, per the National Standard of Canada section B149, 1M91 for category 3 venting: (III). Use Certified venting system provided

by (Manufacturer).2. Tubular heat exchanger units do not require reducers or increasers.

Table PTAC/UH-14-B— Thermostats Type Voltage Range Order No 350-

Single Stage Room Low (24V) 55 - 95°F 0015-01 Duct Low (24V) 55 - 175°F 0015-07 Single Stage* Room with Summer Winter Switch2 Low (24V) 55 - 95°F 0015-02

Room with Summer Winter Switch2 Low (24V) 45 - 85°F 0015-03 Two Stage Duct Low (24V) 55 - 175°F 0015-08 Electronic Room Low (24V) 60 - 85°F Included in Gas Modulating Duct Low (24V) 65 - 85°F Control Option Price

Override Room (for use with duct) Line 115V 50 - 90°F 0015-05 Universal Guard for Room Thermostats 0015-06 Notes:*When used with a duct furnace, optional fan time delay control must be ordered.1. Two-stage room thermostat with Fan Auto-On Switch and System Off-Auto Switch.2. Summer/winter switch does not lock out the heat.3. The only Thermostats available for Tubular heat exchanger units are Single Stage Room, Order No. 0350-0015-01 and Single Stage Room W/Summer Winter Switch, Order

No. 0350-0015-02.

Table PTAC/UH-14-C— Concentric Vent Terminals Available On Option Ordering No. Separated Combustion Vertical Concentric Vent Kit1 0350-0151-01 Units ONLY Horizontal Concentric Vent Kit2 0350-0152-01Notes:1. Kit includes 5” cap with special attached nonrecirculation disc, special 8” cap with 5” hole and concentric vent box.2. Kit includes 5” cap with special attached nonrecirculation disc, inlet air screen and concentric vent box.

Table PTAC/UH-14-D— Vertical Louver Kits (Propeller and Centrifugal Fan Unit Heaters Only)GPND

030 004 006 007 010 012 015 017 020 022 025 030 035 040 Ordering No. Contact Macon Product Support Quantity Required for Ordering Information

Notes:1. Kits are for use in modifying existing units in the field. Kits for GPND-003 thru 007 are complete assemblies including frame and louvers. Kits for all other units include

individual louver with fastening springs.2. When ordering vertical louvers for new equipment, refer to Table PTAC/UH-11-A.3. These Kits are not available for Tubular Heat Exchanger units.

Indoor Gas Heating ProductsIndoor Unit Accessories(Field Installed)

The State of California requires a steady-state efficiency of 80% forboth indoor and outdoor gas heating equipment. All units shippingto the state of California require intermittent pilot ignition.

Contact Macon Product Support for moreinformation on these products (1-800-322-6495)

Page 301: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PTAC/UH-15 Effective 1/1/06

Table PTAC/UH-15-A— Natural to Propane Gas Conversion Packages — Single StageUnit Type and Size— Converting — Ordering No.

Pilot Type From To 350-0119-Standing GPND-003-A GPPD-003-A 01 Pilot1 GPND-004-A GPPD-004-A 02

GPND-006-A GPPD-006-A 04GPND-007-A GPPD-007-A 06GPND-010-A GPPD-010-A 07GPND-012-A GPPD-012-A 08GCND-012-A GCPD-012-AGPND-015-A GPPD-015-A 09GCND-015-A GCPD-015-AGPND-017-A GPPD-017-A 10GCND-017-A GCPD-017-AGPND-020-A GPPD-020-A 11GCND-020-A GCPD-020-AGPND-022-A GPPD-022-A 12GCND-022-A GCPD-022-AGPND-025-A GPPD-025-A 13GCND-025-A GCPD-025-AGPND-030-A GPPD-030-A 14GCND-030-A GCPD-030-AGPND-035-A GPPD-035-A 15GCND-035-A GCPD-035-AGPND-040-A GPPD-040-A 16GCND-040-A GCPD-040-AGDND-010-A GDPD-010-A 35GDND-012-A GDPD-012-A 36GDND-015-A GDPD-015-A 37GDND-017-A GDPD-017-A 38GDND-020-A GDPD-020-A 39GDND-022-A GDPD-022-A 40GDND-025-A GDPD-025-A 41GDND-030-A GDPD-030-A 42GDND-035-A GDPD-035-A 43GDND-040-A GDPD-040-A 44

Intermittent Pilot2 Not Available — Not AvailableNotes:1. Conversion packages are for use in modifying existing units in the field from Natural Gas to Propane Gas. Use only with units with Single Stage — Standing Pilot gas

controls. D Development Series Only.2. Conversion Packages to convert from Natural Gas to Propane Gas with intermittent pilot ignition are not available.3. When ordering conversion packages, complete Model Number and Serial Number must be included in the body of the order.4. Control product marketing for units with development sequence prior to “D”.5. Kit includes pilot burner, main burner orifices and a spring for the existing valve.6. For these kits you may receive any of the numbers selected due to the fact all kits are the same:

350-0119-01, 02, 04 and 06 – all the same.350-0119-07, 08, 09 and 10 – all the same.350-0119-14, 15 and 16 – all the same.

Indoor Gas Heating ProductsIndoor Unit Accessories(Field Installed)

The State of California requires a steady-state efficiency of 80% forboth indoor and outdoor gas heating equipment. All units shippingto the state of California require intermittent pilot ignition.

Contact Macon Product Support for moreinformation on these products (1-800-322-6495)

Page 302: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PTAC/UH-16Effective 1/1/06

Table PTAC/UH-16-A—Propane to Natural Gas Conversion Packages— Single StageUnit Type and Size— Converting — Ordering No.

Pilot Type From To 350-0119-Standing GPP*-003-A GPN*-003-A 17Pilot1 GPP*-004-A GPN*-004-A 18

GPP*-006-A GPN*-006-A 20GPP*-007-A GPN*-007-A 22GPP*-010-A GPN*-010-A 23GCP*-010-A GCN*-010-AGPP*-012-A GPN*-012-A 24GCP*-012-A GCN*-012-AGPP*-015-A GPN*-015-A 25GCP*-015-A GCN*-015-AGPP*-017-A GPN*-017-A 26GCP*-017-A GCN*-017-AGPP*-020-A GPN*-020-A 27GCP*-020-A GCN*-020-AGPP*-022-A GPN*-022-A 28GCP*-022-A GCN*-022-AGPP*-025-A GPN*-025-A 29GCP*-025-A GCN*-025-AGPP*-030-A GPN*-030-A 30GCP*-030-A GCN*-030-AGPP*-035-A GPN*-035-A 31GCP*-035-A GCN*-035-AGPP*-040-A GPN*-040-A 32GCP*-040-A GCN*-040-AGDP*-010-A GDN*-010-A 47GDP*-012-A GDN*-012-A 48GDP*-015-A GDN*-015-A 49GDP*-017-A GDN*-017-A 50GDP*-020-A GDN*-020-A 51GDP*-022-A GDN*-022-A 52GDP*-025-A GDN*-025-A 53GDP*-030-A GDN*-030-A 54GDP*-035-A GDN*-035-A 55GDP*-040-A GDN*-040-A 56

Intermittent Pilot2 All Units Contact Macon Product SupportNotes:1. Conversion packages are for use in modifying existing units in the field from Propane Gas to Natural Gas. Use only with units with Single Stage gas controls. D Develop-

ment Series Only.2. Conversion Packages — Intermittent Pilot Ignition, are available upon request from the parts department.3. *When ordering conversion packages, complete Model Number and Serial Number must be included in the body of the order. Make sure that the * is replaced by the

development sequence number.4. Kit includes pilot burner, main burner orifices and a gas valve.

Indoor Gas Heating ProductsIndoor Unit Accessories(Field Installed)

The State of California requires a steady-state efficiency of 80% forboth indoor and outdoor gas heating equipment. All units shippingto the state of California require intermittent pilot ignition.

Contact Macon Product Support for moreinformation on these products (1-800-322-6495)

Page 303: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PTAC/UH-17 Effective 1/1/06

Table PTAC/UH-17-A—All Indoor Duct Furnaces (Std., High Effic. and Separated Combustion Units) Heat Exchanger Warranty NetPrices Option Extended Warranty1

5 year 10 yearUnit MBh 2nd-5th year 2nd-10th yearSize input alum 409SS 321SS alum 409SS 321SS010 100012 125015 150017 175020 200022 225025 250030 300035 350040 400Ordering Number 2705-4000-05-00 2705-4000-06-00Product Code 588 588Note:1. The extension applies only to new equipment installed in domestic sales territories and must be ordered prior to start-up.

Table PTAC/UH-17-B—Indoor Unit Shipping WeightsUnit Type 030 004 006 007 010 012 015 017 020 022 025 030 035 040Propeller Unit Heater 70 85 100 110 165 188 210 229 240 266 296 341 405 452High EfficiencyPropeller Unit Heater 79 94 109 119 174 197 219 238 249 275 305 350 414 461High EfficiencyCentrifugal Unit Heater — — — — 262 279 314 336 363 408 427 471 561 594Centrifugal Unit Heater — — — — 253 270 315 335 351 396 415 459 550 582Duct Furnace — — — 140 152 162 180 195 216 224 272 348 360High EfficiencyDuct Furnace — — — — 162 164 174 192 207 228 236 284 360 372Separated CombustionPropeller Unit Heater — — — — 200 228 256 284 312 340 368 432 488 545Centrifugal Unit Heater — — — — 298 330 362 394 426 458 490 558 619 678Separated Combustion — — — — 161 180 188 207 227 246 266 305 344 383Indoor Gas Duct FurnaceTubular Heat Exchanger 72 78 102 108 173 185 195 241 251 — 261 367 381 395Propeller Unit HeaterUnit Size 15 20 30 45Horiz Blower Assy (wt less Motor) 135 155 200 295

The State of California requires a steady-state efficiency of 80% forboth indoor and outdoor gas heating equipment. All units shippingto the state of California require intermittent pilot ignition.

Contact Macon Product Support for moreinformation on these products (1-800-322-6495)

Indoor Gas Heating ProductsIndoor Unit Accessories

Page 304: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PTAC/UH-18Effective 1/1/06

1. Model S Unit Heaters (Tables PTAC/UH-19-A-PTAC/UH-25-E) include stock units,as well as production unit casing withmotor, coil, fan, fin, tube, fan guard andhorizontal louvers.

2. Units with modified coils (odd numberedunits) are generally not suitable for enteringwater temperatures below 180° because oflow final air temperatures. See EngineeringBulletin EB-UH7 (photocopy only availablefrom Inland printing 608-783-4700 or onEAGLE), 15-24 for capacity data.

Table PTAC/UH-18-A—S Unit Heater Coil — Temperature & Pressure LimitationsTube Steam Hot Water

Model S Material O.D. Wall Pres.-PSIG Deg.°F Pres.-PSIG Deg.°F Fin MaterialCopper (Std.) 1'’ .031'’ 75 325 200 325Red Brass 1'’ .049'’ 75 325 260 390 Alum. or CopperSteel 1'’ .049” 75 325 400 450 (Std.)

Table PTAC/UH-18-B—Standard Motors for Model S Unit HeatersTop Avail. Current Thermal Winding

hp Speed Speed Type Bearing Char. Overload Insulation1/50 1075 Variable* TE-TOP Sleeve 115/60/1 Yes ‘’B’’

Shaded Pole1/20 1550 Variable* TE-TOP Sleeve 115/60/1 Yes ‘’B’’

Shaded Pole1/8 1550 Variable* TE-TOP Sleeve 115/60/1 Yes ‘’B’’

Perm. Split Cap.1/6-1/4-1/2 1100 1 TE-TOP Ball 115/60/1 Yes ‘’B’’

Perm. Split Cap.1/6-1/4-1/2 1140 1 3-Phase Ball 208/230/460/60/3 No ‘’B’’

3/4 1140 1 3-Phase Ball 208/230/460/60/3 No “B”1/6-1/4-1/2 1140 1 Exp. Proof Ball 115/60/1 Yes “B”

Class I, Group D 208/230/460/60/3 Yes “B”3/4 1145 1 Class II, Group F & G Ball 208/230/460/60/3 Yes “B”

Divisions I And IINOTES:1. Special motors (575/60/3) may be ordered by using appropriate designators in the 13th and 14th digits of the model number. Contact St. Louis (888-872-6302) for availability.2. Unit sizes 18S thru 100S with 115/60/1 motors can be operated at variable speeds with the addition of solid-state speed control from Table PTAC/UH-25-B.3. TE = Totally enclosed.4. TOP = Thermal overload protection.

Propeller Type Unit HeatersModel S — Horizontal Units

3. CoilsThe standard coil is 1-row 0.031'’ wall 1'’O.D. copper tubing with 108 Sigma-Flo®

aluminum fins per foot and are suitable forservice on steam to 75 psi and water at325° at 200 psi. Coil variations are asindicated inPTAC/UH-18-A.

Unit heater name plates will use the 11th digitof the 21 digit model number system todesignate the coil tube material as follows —

A — STD. COPPER

C — RED BRASS

F — STEEL

4. MotorsStandard cycle motors are indicated inPTAC/UH-18-B.

These items are not available to all distribution channels.Please contact your distributor or local sales office for moreinformation.

Contact Waco Product Support for moreinformation on these products (1-888-872-6335)

Page 305: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PTAC/UH-19 Effective 1/1/06

Table PTAC/UH-19-A—Packed Stock Horizontal Model S Unit Heaters Constant SpeedCapacities

Louver Fin Steam @2# and Hot Water @200° EWTDiffuser 60° EAT 60° EAT and 20° WTD

Unit Unit Order No. UnitModel Order Digit 17 Ship cfm Final Model

No. No. B hp rpm wt. # @ 70 Mbh Temp. Mbh gpm No.UHSA- 0136- Model S Horizontal Units — Standard Full Coil

18S 0101-01 4601-3049-01 1/50 1075 38 280 17.4 117 3.5 .36 18S20S-2 0102-01 4601-3049-01 1/50 1075 40 318 20.0 118 6.4 .66 20S-238S 0103-01 4601-3049-01 1/20 1550 42 544 38.7 126 19.1 1.97 38S42S 0104-01 4601-3049-01 1/20 1550 42 590 41.6 125 20.0 2.06 42S60S 0105-01 4601-3049-02 1/20 1550 57 815 60.5 129 34.6 3.56 60S70S 0106-01 4601-3049-02 1/8 1550 61 1100 68.2 117 40.4 4.17 70S90S 0107-01 4601-3049-03 1/8 1550 73 1214 87.6 127 55.7 5.74 90S100S 0108-01 4601-3049-03 1/8 1550 84 1535 96.0 118 62.5 6.44 100S126S 0109-01 4601-3049-04 1/6 1100 102 1760 125.7 126 84.9 8.74 126S168S 0110-01 4601-3049-05 1/6 1100 145 2380 172.0 127 115.3 11.88 168S186S 0111-01 4601-3049-05 1/4 1100 147 2808 185.2 121 125.4 12.92 186S230S 0112-01 4601-3049-06 1/4 1100 190 3300 229.7 124 161.7 16.67 230S260S 0113-01 4601-3049-06 1/2 1100 195 4100 256.3 118 181.1 18.67 260S320S 0114-01 4601-3049-07 1/2 1100 245 4480 324.0 127 234.3 24.15 320S354S 0115-01 4601-3049-07 1/2 1100 250 5660 355.5 118 264.9 27.30 354S

Notes:1. All units on this page are carried in stock (limited quantities) for immediate shipment.2. All stock units have single phase motors.3. Unit sizes 18S thru 100S with 115/60/1 std. motors can be operated at variable speeds with addition of solid-state speed control from Table PTAC/UH-25-B.

These items are not available to all distribution channels.Please contact your distributor or local sales office for moreinformation.

Contact Waco Product Support for moreinformation on these products (1-888-872-6335)

Propeller Type Unit HeatersModel S — Constant Speed

Page 306: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PTAC/UH-20Effective 1/1/06

Table PTAC/UH-20-A—Model S Unit and Motor SelectionsUnit Motor MotorSize hp rpm Voltage Type 13th Digit / 14th Digit018 1/50 1075 115/60/1 TE 1/ T

1/6 1140 208/230/460/60/3 TE (2,3,4)/ T1/6 1140 115/60/1 X-Proof 1/E1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T

019 1/50 1075 115/60/1 TE 1/ T1/6 1140 208/230/460/60/3 TE (2,3,4)/ T1/6 1140 115/60/1 X-Proof 1/E1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T

020 1/50 1075 115/60/1 TE 1/ T1/6 1140 208/230/460/60/3 TE (2,3,4)/ T1/6 1140 115/60/1 X-Proof 1/E1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T

031 1/20 1550 115/60/1 TE 1/ T1/6 1140 208/230/460/60/3 TE (2,3,4)/ T1/6 1140 115/60/1 X-Proof 1/E1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T

038 1/20 1550 115/60/1 TE 1/ T1/6 1140 208/230/460/60/3 TE (2,3,4)/ T1/6 1140 115/60/1 X-Proof 1/E1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T

042 1/20 1550 115/60/1 TE 1/ T1/6 1140 208/230/460/60/3 TE (2,3,4)/ T1/6 1140 115/60/1 X-Proof 1/E1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T

045 1/20 1550 115/60/1 TE 1/ T1/6 1140 208/230/460/60/3 TE (2,3,4)/ T1/6 1140 115/60/1 X-Proof 1/E1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T

053 1/8 1550 115/60/1 TE 1/ T1/6 1140 208/230/460/60/3 TE (2,3,4)/ T1/6 1140 115/60/1 X-Proof 1/E1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T

060 1/20 1550 115/60/1 TE 1/ T1/6 1140 208/230/460/60/3 TE (2,3,4)/ T1/6 1140 115/60/1 X-Proof 1/E1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T

Propeller Type Unit HeatersModel S Unit and Motor Selections

These items are not available to all distribution channels.Please contact your distributor or local sales office for moreinformation.

Contact Waco Product Support for moreinformation on these products (1-888-872-6335)

Page 307: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PTAC/UH-21 Effective 1/1/06

Propeller Type Unit HeatersModel S Unit and Motor Selections

Table PTAC/UH-21-A—Model S Unit and Motor Selections (Continued)Unit Motor MotorSize HP RPM Voltage Type 13th Digit / 14th Digit069 1/8 1550 115/60/1 TE 1/ T

1/6 1140 208/230/460/60/3 TE (2,3,4)/ T1/6 1140 115/60/1 X-Proof 1/E1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T

070 1/8 1550 115/60/1 TE 1/ T1/6 1140 208/230/460/60/3 TE (2,3,4)/ T1/6 1140 115/60/1 X-Proof 1/E1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T

077 1/8 1550 115/60/1 TE 1/ T1/6 1140 208/230/460/60/3 TE (2,3,4)/ T1/6 1140 115/60/1 X-Proof 1/E1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T

090 1/8 1550 115/60/1 TE 1/ T1/6 1140 208/230/460/60/3 TE (2,3,4)/ T1/6 1140 115/60/1 X-Proof 1/E1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T

091 1/6 1100 115/60/1 TE 1/ T1/6 1140 208/230/460/60/3 TE (2,3,4)/ T1/6 1140 115/60/1 X-Proof 1/E1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T

100 1/8 1550 115/60/1 TE 1/ T1/6 1140 208/230/460/60/3 TE (2,3,4)/ T1/6 1140 115/60/1 X-Proof 1/E1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T

126 1/6 1100 115/60/1 TE 1/ T1/6 1140 208/230/460/60/3 TE (2,3,4)/ T1/6 1140 115/60/1 X-Proof 1/E1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T

127 1/6 1100 115/60/1 TE 1/ T 1/6 1140 208/230/460/60/3 TE (2,3,4)/ T1/6 1140 115/60/1 X-Proof 1/E1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T

137 1/4 1100 115/60/1 TE 1/ T1/4 1140 208/230/460/60/3 TE (2,3,4)/ T1/4 1140 115/60/1 X-Proof 1/E1/4 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T

168 1/6 1100 115/60/1 TE 1/ T1/6 1140 208/230/460/60/3 TE (2,3,4)/ T1/6 1140 115/60/1 X-Proof 1/E1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T

These items are not available to all distribution channels.Please contact your distributor or local sales office for moreinformation.

Contact Waco Product Support for moreinformation on these products (1-888-872-6335)

Page 308: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PTAC/UH-22Effective 1/1/06

Table PTAC/UH-22-A—Model S Unit and Motor Selections (Continued)Unit MotorSize HP RPM Voltage Type Digit 13 / Digit 14181 1/4 1100 115/60/1 TE 1/ T

1/4 1140 208/230/460/60/3 TE (2,3,4)/ T1/4 1140 115/60/1 X-Proof 1/E1/4 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T

186 1/4 1100 115/60/1 TE 1/ T1/4 1140 208/230/460/60/3 TE (2,3,4)/ T1/4 1140 115/60/1 X-Proof 1/E1/4 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T

207 1/2 1100 115/60/1 TE 1/ T1/2 1140 208/230/460/60/3 TE (2,3,4)/ T1/2 1140 115/60/1 X-Proof 1/E3/4 1145 208/230/460/60/3 X-Proof (2,3,4)/E1/2 1140 575/60/3 Totally Enclosed 5/T

230 1/4 1100 115/60/1 TE 1/ T1/4 1140 208/230/460/60/3 TE (2,3,4)/ T1/4 1140 115/60/1 X-Proof 1/E1/4 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T

243 1/2 1100 115/60/1 TE 1/ T1/2 1140 208/230/460/60/3 TE (2,3,4)/ T1/2 1140 115/60/1 X-Proof 1/E3/4 1145 208/230/460/60/3 X-Proof (2,3,4)/E1/2 1140 575/60/3 Totally Enclosed 5/T

260 1/2 1100 115/60/1 TE 1/ T1/2 1140 208/230/460/60/3 TE (2,3,4)/ T1/2 1140 115/60/1 X-Proof 1/E3/4 1145 208/230/460/60/3 X-Proof (2,3,4)/E1/2 1140 575/60/3 Totally Enclosed 5/T

273 1/2 1100 115/60/1 TE 1/ T1/2 1140 208/230/460/60/3 TE (2,3,4)/ T1/2 1140 115/60/1 X-Proof 1/E3/4 1145 208/230/460/60/3 X-Proof (2,3,4)/E1/2 1140 575/60/3 Totally Enclosed 5/T

320 1/2 1100 115/60/1 TE 1/ T1/2 1140 208/230/460/60/3 TE (2,3,4)/ T1/2 1140 115/60/1 X-Proof 1/E3/4 1145 208/230/460/60/3 X-Proof (2,3,4)/E1/2 1140 575/60/3 Totally Enclosed 5/T

354 1/2 1100 115/60/1 TE 1/ T1/2 1140 208/230/460/60/3 TE (2,3,4)/ T1/2 1140 115/60/1 X-Proof 1/E3/4 1145 208/230/460/60/3 X-Proof (2,3,4)/E1/2 1140 575/60/3 Totally Enclosed 5/T

400 3/4 1140 208/230/460/60/3 TE (2,3,4)/ T3/4 1145 208/230/460/60/3 X-Proof (2,3,4)/E3/4 1140 575/60/3 Totally Enclosed 5/T

Units in boldboldboldboldbold print can also be ordered from packed stock. See Table PTAC/UH-19-A for stock ordering number.Notes:1. Units with modified coils (odd numbered units; 019, 031, etc.) are used in applications with lower final temperatures. These units not available as packed stock.2. All single-phase motors have built-in overload protection.3. 115/60/1, TE motors on unit sizes 18S-90S and 100S can be operated at variable speeds with the addition of a solid-state speed control. See Table PTAC/UH-25-B for selection.4. All explosion-proof motors meet Class I, Group D; Class II, Group F and G; Divisions 1 and 2.5. Verify electrical characteristics of motors are ordered correctly.6. Special motor requirements are available. Contact St. Louis (888-872-6302) for availability.7. TE = Totally Enclosed8. X-Proof = Explosion Proof

Propeller Type Unit HeatersModel S Unit and Motor Selections

These items are not available to all distribution channels.Please contact your distributor or local sales office for moreinformation.

Contact Waco Product Support for moreinformation on these products (1-888-872-6335)

Page 309: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PTAC/UH-23 Effective 1/1/06

TTable PTAC/UH-23-A—Model S Coil TypeUnit Size Designator

018 SW

019* SW

020 SW

031* SW

038 SW

042 SW

045* SW

053* SW

060 SW

069* SW

070 SW

077* SW

090 SW

091* SW

100 SW

126 SW

127* SW

137* SW

168 SW

181* SW

186 SW

207* SW

230 SW

243* SW

260 SW

273* SW

320 SW

354 SW

400 SW

*Units have modified coil for lower outlet temperatures.Notes:1. Std = Standard2. Type “S” coils can be operated with either steam or hot water.3. Type “W” coils are for use with hot water only and have turbulators.

Table PTAC/UH-23-B—Model S Fin SeriesUnit Size Designator

018 82

019 82

020 82

031 82

038 82

042 82

045 82

053 82

060 82

069 82

070 82

077 82

090 82

091 82

100 82

126 82

127 82

137 82

168 82

181 82

186 82

207 82

230 82

243 82

260 82

273 82

320 82

354 82

400 82

Notes:1. Std = Standard2. N/C = No Charge3. Selection of digit “8” equals 108 fins per foot.4. Selection of digit “2” equals 132 fins per foot.5. 132 fins per foot is standard on models 020, 019 and 400.

These items are not available to all distribution channels.Please contact your distributor or local sales office for moreinformation.

Contact Waco Product Support for moreinformation on these products (1-888-872-6335)

Propeller Type Unit HeatersModel S Coil and Fin

Page 310: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PTAC/UH-24Effective 1/1/06

Table PTAC/UH-24-B—(Continued) Model S Tube MaterialUnit Size Type Designator

126 Copper ARed Brass CSteel F

127 Copper ARed Brass CSteel F

137 Copper ARed Brass CSteel F

168 Copper ARed Brass CSteel F

181 Copper ARed Brass CSteel F

186 Copper ARed Brass CSteel F

207 Copper ARed Brass CSteel F

230 Copper ARed Brass CSteel F

243 Copper ARed Brass CSteel F

260 Copper ARed Brass CSteel F

273 Copper ARed Brass CSteel F

320 Copper ARed Brass CSteel F

354 Copper ARed Brass CSteel F

400 Copper ARed Brass CSteel F

Note:1. Std = Standard2. Tube temperature and pressure limitations found in Table PTAC/UH-18-A.

Table PTAC/UH-24-A—Model S Tube MaterialUnit Size Type Designator

018 Copper ARed Brass CSteel F

019 Copper ARed Brass CSteel F

020 Copper ARed Brass CSteel F

031 Copper ARed Brass CSteel F

038 Copper ARed Brass CSteel F

042 Copper ARed Brass CSteel F

045 Copper ARed Brass CSteel F

053 Copper ARed Brass CSteel F

060 Copper ARed Brass CSteel F

069 Copper ARed Brass CSteel F

070 Copper ARed Brass CSteel F

077 Copper ARed Brass CSteel F

090 Copper ARed Brass CSteel F

091 Copper ARed Brass CSteel F

100 Copper ARed Brass CSteel F

These items are not available to all distribution channels.Please contact your distributor or local sales office for moreinformation.

Contact Waco Product Support for moreinformation on these products (1-888-872-6335)

Propeller Type Unit HeatersModel S Tube Material

Page 311: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PTAC/UH-25 Effective 1/1/06

Table PTAC/UH-25-A—Model S Louver Fin DiffuserUnit Size Ordering Number Digit 17

018 4601-3049-01 B019 4601-3049-01 B020 4601-3049-01 B031 4601-3049-01 B038 4601-3049-01 B042 4601-3049-01 B045 4601-3049-02 B053 4601-3049-02 B060 4601-3049-02 B069 4601-3049-03 B070 4601-3049-02 B077 4601-3049-03 B090 4601-3049-03 B091 4601-3049-04 B100 4601-3049-03 B126 4601-3049-04 B127 4601-3049-05 B137 4601-3049-05 B168 4601-3049-05 B181 4601-3049-06 B186 4601-3049-05 B207 4601-3049-06 B230 4601-3049-06 B243 4601-3049-07 B260 4601-3049-06 B273 4601-3049-07 B320 4601-3049-07 B354 4601-3049-07 B400 4601-3049-07 B

Table PTAC/UH-25-B—Model S & P Starter and ControlAccessoriesOrdering ModelNumber Number DescriptionX13011500 600 TAX 4 Manual Starter without 1

overload protectionX13510361-01 T451A Light-Duty Thermostat 2X13530027-01 Q473B Light-Duty Subbase 3X13080500 T6051A Heavy-Duty Thermostat 4X13530028-01 Q651A Heavy-Duty Subbase 5136-0162-01 KBWC-15 Solid-State Speed Control 6

Table PTAC/UH-25-D—Model S OSHA Wire Guards(Standard Units Only)

Unit Size Ordering Number018 0136-0251-01019 0136-0251-02020 0136-0251-03031 0136-0251-04038 0136-0251-05042 0136-0251-06045 0136-0252-01053 0136-0252-03060 0136-0252-02069 0136-0252-05070 0136-0252-04077 0136-0253-01090 0136-0252-06091 0136-0253-02100 0136-0253-03126 0136-0253-04127 0136-0254-03137 0136-0254-04168 0136-0254-01181 0136-0254-05186 0136-0254-02207 0136-0255-01230 0136-0254-06243 0136-0255-02260 0136-0255-03273 0136-0255-04320 0136-0255-05354 0136-0255-06

Notes:1. OSHA guards will be factory installed when ordered with a corresponding standard unit

heater.2. Field installation of “type 2” motor mounts (three-phase and explosion-proof motors)

requires cutting portions of the guard to fit over motor side arm. Guards are not OSHA.3. To order OSHA guards for standard unit, digit 15 must be A.To order OSHA guards for standard unit, digit 15 must be A.To order OSHA guards for standard unit, digit 15 must be A.To order OSHA guards for standard unit, digit 15 must be A.To order OSHA guards for standard unit, digit 15 must be A.

Table PTAC/UH-25-E—Special Coatings for Model S Unit HeatersEpoxy Baked

Unit Size Epoxy Phenolic Phenolic18,19,20,31,38,42,45,5360,69,70,77,90,91100,126,127,137168,181,186,207,230243,260,273,320354,400Digit 17/D: Any Coating on All Louver Fin Diffusers =Notes:1. Surface preparation: sandblasting, except coils which are chemically cleaned. Inside and

outside of each casing, fan blade and heating coil are special coated. Motors cannot bespecial coated.

2. Epoxy Coating (Digit 16/R)(Digit 16/R)(Digit 16/R)(Digit 16/R)(Digit 16/R) : Two coats on all subassemblies and one coat on assembled.Unit force cured at 150° F.

3. Epoxy Phenolic Coating (Digit 16/T)(Digit 16/T)(Digit 16/T)(Digit 16/T)(Digit 16/T): Two coats on all subassemblies and one coat onassembled. Unit force cured at 150°F.

4. Baked Phenolic Coating (Digit 16/W)(Digit 16/W)(Digit 16/W)(Digit 16/W)(Digit 16/W): Four coats on all surfaces. Baked at 325°F onintermediate coats and 425°F on cure.

5. To order, enter appropriate designator in digit 16.6. All units reshipped in original cartons.

Table PTAC/UH-25-C— Model S & P Starter andControl Accessories (Continued)Digit Designator18 A20 B21 E20 C21 F19 DNotes:1. NEMA Type 1, single-pole, single-throw, one hp, 110 220V, toggle operated. For

use on single-phase operation only.2. Line voltage 8.0 Amps, 56°-94° range.3. Auto-off. For use with light duty thermostat.4. Line voltage 16.0 Amps, 45°-85° range.5. Auto-off-on for use with heavy-duty thermostat.6. 120V, five Amps. (Only available up to 100S).

These items are not available to all distribution channels.Please contact your distributor or local sales office for moreinformation.

Contact Waco Product Support for moreinformation on these products (1-888-872-6335)

Propeller Type Unit HeatersModel S Accessories and Coatings

Page 312: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PTAC/UH-26Effective 1/1/06

1. Model P Unit Heaters (Tables PTAC/UH-27-A-PTAC/UH-30-A) include stock units,as well as production unit casing withmotor, coil, fin, tube, fan guard and fan.

2. Model PL Unit Heaters are identical toModel P. The performance difference is aresult of removing the air ports in the field.

3. CoilsThe standard coil 1-row 0.025'’ wall 5/8'’O.D. copper with 144 Sigma-Flo® aluminumfins per foot and threaded steel pipeheaders. Coils are suitable for service on75 psi steam or water at 325 F at 225 psi.Coil variations are as indicated in TablePTAC/UH-26-A.

Table PTAC/UH-26-A—Type ‘’P’’ Unit Heater Coil — Temperature & Pressure LimitationsTube Steam Hot Water

Model P Material O.D. Wall Pres.-PSIG Deg.°F Pres.-PSIG Deg.°F Fin MaterialCopper (Std.) 5/8'’ .025'’ 75 325 225 325Red Brass 5/8'’ .049'’ 75 325 300 425 Alum. or CopperSteel 5/8'’ .049'’ 75 325 400 450 (Std.)

Table PTAC/UH-26-B—Standard Motors for Model P Unit HeatersTop Avail. Current Thermal Winding

hp Speed Speed Type Bearing Char. Overload Insulation1/40-1/20 1550 Variable TE-TOP Sleeve 115/60/1 Yes ‘’B’’

Shaded Pole1/8 1070 Variable TE-TOP PSC Sleeve 115/60/1 Yes ‘’B’’

1/6-1/4-1/2 1100 1 TE-TOP Ball 115/60/1 Yes ‘’B’’Perm. Split Cap.

1/6-1/4-1/2 1140 1 3-Phase Ball 208/230/460/60/3 No ‘’B’’3/4 1140 1 TE Polyphase Ball 208/230/460/60/3 No ‘’B’’1½ 1160 1 TE Polyphase Ball 208/230/460/60/3 No “B”3 1165 1 TE Polyphase Ball 208/230/460/60/3 No “B”

1/6-1/4-1/2 1140 1 Exp. Proof Ball 115/60/1 Yes “B”3 1150 1 Class I, Group D Ball 208/230/460/60/3 Yes “B”

3/4 1145 1 Class II, Group F & G Ball 230/460/60/3 Yes “B”Divisions I and II

1½ 1150 1 Ball 230/460/60/3 Yes “B”1. Special motors (575/60/3) may be ordered by using appropriate designators in digits 13 and 14 of model number. Contact St. Louis

(888-872-6302) for availability.2. Unit sizes 42P thru 102P may be operated as variable speeds with addition of solid-state control from Table PTAC/UH-29-C.3. TE = Totally Enclosed4. TOP = Thermal Overload Protection5. PSC = Permanent Split Capacitor.

Propeller Type Unit HeatersModel P — Vertical Units

4. Unit heater name plates will use the 11thdigit of the 21 digit model number systemto designate the coil tube material asfollows:A — STD. COPPERC — RED BRASSF — STEEL

5. MotorsStandard cycle motors are described inTable PTAC/UH-26-B.Special motors may be ordered.(575/60/3) by putting appropriatedesignators in Digits 13 and 14 of modelnumber. Contact St. Louis (888-872-6302)

These items are not available to all distribution channels.Please contact your distributor or local sales office for moreinformation.

Contact Waco Product Support for moreinformation on these products (1-888-872-6335)

Page 313: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PTAC/UH-27 Effective 1/1/06

Table PTAC/UH-27-A—Packed Stock Vertical Model P Unit Heaters Constant SpeedCapacities

Steam @2# and Hot Water @200° EWT Louver (Digit 17/A) 60° EAT 60° EAT and 20° WTD

Unit Unit Cone UnitModel Order Diffuser Ship cfm Final Model

No. No. Order No. hp rpm wt. # @ 70 Mbh Temp. Mbh gpm No.UHPA- 136- Model P (Standard Vertical Units)42P* 0143-01 4607-330-01 1/40 1550 28 595 41.3 124 22.7 2.34 42P64P* 0144-01 4607-330-02 1/20 1550 37 989 65.5 121 39.6 4.08 64P80P* 0145-01 4607-330-02 1/20 1550 41 1200 80.6 122 48.4 4.99 80P102P* 0146-01 4607-330-03 1/8 1070 57 1490 101.8 123 68.3 7.03 102P122P 0147-01 4607-330-03 1/6 1100 57 1790 124.4 124 83.7 8.63 122P146P 0148-01 4607-330-04 1/6 1100 80 2220 152.0 123 105.2 10.84 146P166P 0149-01 4607-330-04 1/6 1100 82 2620 173.0 121 118.6 12.22 166P202P 0150-01 4607-330-04 1/4 1100 86 3200 201.2 118 139.7 14.40 202P252P 0151-01 4607-330-05 1/4 1100 134 4180 249.8 115 180.1 18.56 252P280P 0152-01 4607-330-05 1/2 1100 134 4430 283.8 119 205.4 21.17 280P336P 0153-01 4607-330-05 3/4 1140 144 5210 333.4 119 242.9 25.03 336P

UHPA- 136- P-L (Standard Model P with all Air-Ports Opened)42P* 0143-01 4607-330-01 1/40 1550 28 668 34.8 108 18.9 1.95 42P64P* 0144-01 4607-330-02 1/20 1550 37 1200 57.2 104 34.2 3.53 64P80P* 0145-01 4607-330-02 1/20 1550 41 1360 68.0 106 40.5 4.17 80P102P* 0146-01 4607-330-03 1/8 1070 57 1640 85.4 108 56.5 5.82 102P122P 0147-01 4607-330-03 1/6 1100 57 2180 111.0 107 73.9 7.62 122P146P 0148-01 4607-330-04 1/6 1100 80 2360 125.8 109 85.5 8.81 146P166P 0149-01 4607-330-04 1/6 1100 82 2920 149.0 107 100.7 10.38 166P202P 0150-01 4607-330-04 1/4 1100 86 3390 176.8 108 121.5 12.52 202P252P 0151-01 4607-330-05 1/4 1100 134 4500 214.9 104 153.8 15.85 252P280P 0152-01 4607-330-05 1/2 1100 134 5040 251.8 106 180.1 18.56 280P336P 0153-01 4607-330-05 3/4 1140 144 5700 291.0 107 210.6 21.70 336P

*These units may be operated as variable speed with the addition of the solid-state control from Table PTAC/UH-29-C.Notes:1. All stock units have single phase motors except the 336P which has three-phase.2. All units on this page are available from stock for immediate shipment. Contact St. Louis (888-872-6302) for availability.3. Be sure the electrical characteristics of motors ordered are correct.

Table PTAC/UH-27-B—Model P Unit and Motor SelectionsUnit Motor MotorSize hp rpm Voltage Type 13th Digit / 14th Digit042 1/40 1550 115/60/1 TE 1/T

1/6 1140 208/230/460/60/3 TE (2,3,4)/T1/6 1140 115/60/1 X-Proof 1/E1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T

064 1/20 1550 115/60/1 TE 1/T1/6 1140 208/230/460/60/3 TE (2,3,4)/T1/6 1140 115/60/1 X-Proof 1/E1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T

080 1/20 1550 115/60/1 TE 1/T1/6 1140 208/230/460/60/3 TE (2,3,4)/T1/6 1140 115/60/1 X-Proof 1/E1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T

102 1/8 1070 115/60/1 TE 1/T1/6 1140 208/230/460/60/3 TE (2,3,4)/T1/6 1140 115/60/1 X-Proof 1/E1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T

122 1/6 1100 115/60/1 TE 1/T1/6 1140 208/230/460/60/3 TE (2,3,4)/T1/6 1140 115/60/1 X-Proof 1/E1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T

These items are not available to all distribution channels.Please contact your distributor or local sales office for moreinformation.

Contact Waco Product Support for moreinformation on these products (1-888-872-6335)

Propeller Type Unit HeatersModel P — Constant Speed andMotor Selections

Page 314: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PTAC/UH-28Effective 1/1/06

Table PTAC/UH-28-A— Model P Unit and Motor Selections (Continued)Unit Motor MotorSize hp rpm Voltage Type 13th Digit / 14th Digit146 1/6 1100 115/60/1 TE 1/T

1/6 1140 208/230/460/60/3 TE (2,3,4)/T1/6 1140 115/60/1 X-Proof 1/E1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T

166 1/6 1100 115/60/1 TE 1/T1/6 1140 208/230/460/60/3 TE (2,3,4)/T1/6 1140 115/60/1 X-Proof 1/E1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T

202 1/4 1100 115/60/1 TE 1/T1/4 1140 208/230/460/60/3 TE (2,3,4)/T1/4 1140 115/60/1 X-Proof 1/E1/4 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T

252 1/4 1100 115/60/1 TE 1/T1/4 1140 208/230/460/60/3 TE (2,3,4)/T1/4 1140 115/60/1 X-Proof 1/E1/4 1140 208/230/460/60/3 X-Proof (2,3,4)/E1/3 1140 575/60/3 Totally Enclosed 5/T

280 1/2 1100 115/60/1 TE 1/T1/2 1140 208/230/460/60/3 TE (2,3,4)/T1/2 1140 115/60/1 X-Proof 1/E1/2 1140 230/460/60/3 X-Proof (3,4)/E1/2 1140 575/60/3 Totally Enclosed 5/T

336 3/4 1140 208/230/460/60/3 TE (2,3,4)/T3/4 1145 208/230/460/60/3 X-Proof (2,3,4)/E3/4 1140 575/60/3 Totally Enclosed 5/T

384 3/4 1140 208/230/460/60/3 TE (2,3,4)/T3/4 1145 208/230/460/60/3 X-Proof (2,3,4)/E3/4 1140 575/60/3 Totally Enclosed 5/T

500 1-½ 1160 208/230/460/60/3 TE (2,3,4)/T1-½ 1150 230/460/60/3 X-Proof (3,4)/E1-½ 1160 575/60/3 Totally Enclosed 5/T

600 1-½ 1160 208/230/460/60/3 TE (2,3,4)/T1-½ 1150 230/460/60/3 X-Proof (3,4)/E1-½ 1160 575/60/3 Totally Enclosed 5/T

720 3 1165 208/230/460/60/3 TE (2,3,4)/T3 1150 230/460/60/3 X-Proof (3,4)/E3 1165 575/60/3 Totally Enclosed 5/T

Units in boldboldboldboldbold print can be ordered from packed stock. See Table PTAC/UH-27-A for ordering information.Notes:1. All single-phase motors have built-in overload protection.2. All explosion-proof motors meet Class I, Group D; Class II, Group F and G; Divisions 1 and 2.

These items are not available to all distribution channels.Please contact your distributor or local sales office for moreinformation.

Contact Waco Product Support for moreinformation on these products (1-888-872-6335)

Propeller Type Unit HeatersModel P — Motor Selections

Page 315: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PTAC/UH-29 Effective 1/1/06

Table PTAC/UH-29-A—Model P Tube MaterialUnit Size Type Designator042 Copper A

Red Brass CSteel F

064 Copper ARed Brass CSteel F

080 Copper ARed Brass CSteel F

102 Copper ARed Brass CSteel F

122 Copper ARed Brass CSteel F

146 Copper ARed Brass CSteel F

166 Copper ARed Brass CSteel F

202 Copper ARed Brass CSteel F

252 Copper ARed Brass CSteel F

280 Copper ARed Brass CSteel F

336 Copper ARed Brass CSteel F

384 Copper ARed Brass CSteel F

500 Copper ARed Brass CSteel F

600 Copper ARed Brass CSteel F

720 Copper ARed Brass CSteel F

Notes:1. Std = Standard2. Tube temperature and pressure limitations found in Table PTAC/UH-26-A.

Table PTAC/UH-29-B—Model P Louver Cone DiffuserUnit Size Designator Digit 17042 4607-0330-01 A064 4607-0330-02 A080 4607-0330-02 A102 4607-0330-03 A122 4607-0330-03 A146 4607-0330-04 A166 4607-0330-04 A202 4607-0330-04 A252 4607-0330-05 A280 4607-0330-05 A336 4607-0330-05 A384 4607-0330-05 A500 4607-0330-06 A600 4607-0330-06 A720 4607-0330-06 A

Table PTAC/UH-29-C—Model S & P Starter and ControlAccessoriesOrdering ModelNumber Number DescriptionX13011500 600 TAX 4 Manual Starter without1

overload protectionX13510361-01 T451A A Light-Duty Thermostat2

X13530027-01 Q473B Light-Duty Subbase3

X13080500 T6051A Heavy-Duty Thermostat4

X13530028-01 Q651A Heavy-Duty Subbase5

136-0162-01 KBWC-15 Solid-State Speed Control6

Table PTAC/UH-29-D— Model S & P Starter andControl Accessories (Continued)Digit Designator18 A20 B21 E20 C21 F19 DNotes:1. NEMA Type 1, single-pole, single-throw, one hp, 110-220V toggle operated. For

use on single-phase operation only.2. Line voltage 8.0 Amps, 56°-94° range.3. Auto-off. For use with light duty thermostat.4. Line voltage 16.0 Amps, 45°-85° range.5. Auto-off-on for use with heavy-duty thermostat.6. 120V, Five Amps.

Table PTAC/UH-29-E—Model P OSHA Wire GuardsUnit Size Designator Digit 15042 0136-0256-01 A064 0136-0257-01 A080 0136-0257-02 A102 0136-0258-01 A122 0136-0258-02 A146 0136-0259-01 A166 0136-0259-02 A202 0136-0259-03 A252 0136-0260-01 A280 0136-0260-02 A336 0136-0260-03 A384 0136-0260-04 A500 0136-0261-01 A600 0136-0261-02 A720 0136-0261-03 A

Notes:1. OSHA guards will be factory installed when ordered with a corresponding unit

heater.2. For the 3-phase and explosion-proof motor, the OSHA guard ships separately.

These items are not available to all distribution channels.Please contact your distributor or local sales office for moreinformation.

Contact Waco Product Support for moreinformation on these products (1-888-872-6335)

Propeller Type Unit HeatersModel P — Accessories

Page 316: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PTAC/UH-30Effective 1/1/06

Table PTAC/UH-30-C— Packed Stock Model P Unit Heater Order Numbers & Equivalent Production Model NumbersVertical Model P Unit Heaters Constant Speed

Stock Order Production OrderSize Order No. Type Model No. Type Notes42P 136-0143-01 STK UHPA042P4CAA1T0000000 PRD 164P 136-0144-01 STK UHPA064P4CAA1T0000000 PRD 180P 136-0145-01 STK UHPA080P4CAA1T0000000 PRD 1102P 136-0146-01 STK UHPA102P4CAA1T0000000 PRD 1122P 136-0147-01 STK UHPA122P4CAA1T0000000 PRD 1146P 136-0148-01 STK UHPA146P4CAA1T0000000 PRD 1166S 136-0149-01 STK UHPA166P4CAA1T0000000 PRD 1202P 136-0150-01 STK UHPA202P4CAA1T0000000 PRD 1252P 136-0151-01 STK UHPA252P4CAA1T0000000 PRD 1280P 136-0152-01 STK UHPA280P4CAA1T0000000 PRD 1336P* 136-0153-01 STK UHPA336P4CAA1T0000000 PRD 1Notes:1. For steam or hot water coils made from .025 copper tubes. Aluminum fins (144 per foot) and steel pipe headers. Fans made with steel hubs and aluminum blades. Sleeve

bearing motors are provided for 1/20 & 1/8 HP ranges and ball bearing motors provided for 1/6, 1/4, & 1/2 HP ranges are 115/60/1. TE with TOP and class B insulation. Steelmotor mount furnished. Variable speed motors furnished on sizes 42P thru 102P as standard. Requires a solid-state speed control which must be ordered separately. Casingsmade from two steel plates with the top plate having air ports as standard, phosphatized and painted with a blue-gray baked enamel finish.

*Size 336P stock unit uses a 230/460/60/3, ball bearing, TE with class B insulation motor as standard.

Table PTAC/UH-30-B— Packed Stock Model S Unit Heater Order Numbers & Equivalent Production Model NumbersHorizontal Model S Unit Heaters Constant Speed

Stock Order Production OrderSize Order No. Type Model No. Type Notes18S 136-0101-01 STK UHSA018S8EAA1T0000000 PRD 120S2* 136-0102-01 STK UHSA020S2EAA1T0000000 PRD 138S 136-0103-01 STK UHSA038S8EAA1T0000000 PRD 142S 136-0104-01 STK UHSA042S8EAA1T0000000 PRD 160S 136-0105-01 STK UHSA060S8EAA1T0000000 PRD 170S 136-0106-01 STK UHSA070S8EAA1T0000000 PRD 190S 136-0107-01 STK UHSA090S8EAA1T0000000 PRD 1100S 136-0108-01 STK UHSA100S8EAA1T0000000 PRD 1126S 136-0109-01 STK UHSA126S8EAA1T0000000 PRD 1168S 136-0110-01 STK UHSA168S8EAA1T0000000 PRD 1186S 136-0111-01 STK UHSA186S8EAA1T0000000 PRD 1230S 136-0112-01 STK UHSA230S8EAA1T0000000 PRD 1260S 136-0113-01 STK UHSA260S8EAA1T0000000 PRD 1320S 136-0114-01 STK UHSA320S8EAA1T0000000 PRD 1354S 136-0115-01 STK UHSA354S8EAA1T0000000 PRD 1Notes:1. For steam or hot water coils made from .031 copper tubes. Aluminum fins (*108 per foot) and steel pipe headers. Fans made with steel hubs and aluminum blades. Sleeve

bearing motors are 115/60/1. TEAOM with TOP and class B insulation. Type No. 1 motor mount (wire guard) furnished. Variable speed motors furnished on sizes 18S thru 100Sas standard. Requires a solid-state speed control which must be ordered separately. Unit casings top, front, back and sides made from steel with adjustable louversphosphatized and painted with a blue-gray baked enamel finish.

*Size 20S2 stock unit furnished with 132 fins per foot as standard.

Table PTAC/UH-30-A— Special Coatings for Model P Unit HeatersEpoxy Baked

Unit Size Epoxy Phenolic Phenolic042, 064, 080102, 122146, 166, 202252, 280, 336, 384500, 600720Digit 17/C - Any Coating on All Louver Cone Diffusers = $248 list priceDigit 17/C - Any Coating on All Louver Cone Diffusers = $248 list priceDigit 17/C - Any Coating on All Louver Cone Diffusers = $248 list priceDigit 17/C - Any Coating on All Louver Cone Diffusers = $248 list priceDigit 17/C - Any Coating on All Louver Cone Diffusers = $248 list priceNotes:1. Surface preparation: sandblasting, except coils which are chemically cleaned. Inside and outside of each casing, fan blade and heating coil are special coated. Motors cannot

be special coated.2. Epoxy Coating Coating (Digit 16/R)(Digit 16/R)(Digit 16/R)(Digit 16/R)(Digit 16/R): Two coats on all subassemblies and one coat on assembled. Unit force cured at 150°F.3. Epoxy Phenolic Coating (Digit 16/T)(Digit 16/T)(Digit 16/T)(Digit 16/T)(Digit 16/T): Two coats on all subassemblies and one coat on assembled. Unit force cured at 150°F.4. Baked Phenolic Coating (Digit 16/W)(Digit 16/W)(Digit 16/W)(Digit 16/W)(Digit 16/W): Four coats on all surfaces. Baked at 325°F on intermediate coats and 425°F on cure. Units are reshipped in original cartons.5. To order, enter appropriate in digit 16 of model number.

These items are not available to all distribution channels.Please contact your distributor or local sales office for moreinformation.

Contact Waco Product Support for moreinformation on these products (1-888-872-6335)

Propeller Type Unit HeatersModel P CoatingsModel S and P Order Numbers andEquivalent Production Numbers

Page 317: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PTAC/UH-31 Effective 1/1/06

These items are not available to all distribution channels.Please contact your distributor or local sales office for moreinformation.

Contact Waco Product Support for moreinformation on these products (1-888-872-6335)

Table PTAC/UH-31-A— Standard with 24V Control Transformer and ContactorOrder Element Std.

kW No. Element & Motor Amp Control ShipRating UHEC 236- Phase Voltage Rating Voltage wt lbs

031AACA -246 1 208 15.9 24 253.3 kW 031CACA -248 1 277 11.9 24 25

033DACA -182 3 480 4.0 24 25052AACA -250 1-3 208 24.1 24 25

5.0 kW 052BACA -252 1-3 240/208 20.9/18.1 24 25053DACA -194 3 480 6.1 24 25072AACA -196 1-3 208 36.1 24 50072BACA -198 1-3 240/208 31.3/27.1 24 50

7.5 kW 071CACA -200 1 277 27.1 24 50073DACA -202 3 480 9.1 24 50102AACA -204 1-3 208 47.8 24 50102BACA -206 1-3 240/208 42.2/36.1 24 50

10 kW 101CACA -208 1 277 36.1 24 50103DACA -210 3 480 12.1 24 50153AACA -212 3 208 41.7 24 65

15 kW 153BACA -214 3 240/208 36.1/31.3 24 65153DACA -216 3 480 18.1 24 65203BACA -218 3 240/208 47.8/41.1 24 65

20 kW 203DACA -220 3 480 24.1 24 65253AACA -222 3 208 69.5 24 120

25 kW 253BACA -224 3 240/208 60.2/52.1 24 120253DACA -226 3 480 30.1 24 120303AACA -228 3 208 83.4 24 120

30 kW 303DACA -232 3 480 36.2 24 120403BACA -236 3 240/208 96.4/83.4 24 120

40 kW 403DACA -238 3 480 47.0 24 12050 kW 503DACA -244 3 480 60.3 24 120

1. Supply wire must have 75°C minimum insulation.2. Each Electric Unit Heater in Table PTAC/UH-31-A is provided with a factory installed Transformer and Contactor as standard for 24V control voltage.3. All 25-50 kW units are factory wired for two-stage operation as standard. To operate on two-stage, a two-stage thermostat must be ordered.4. All 25-50 kW units are equipped with two-speed motors and factory installed Speed Switches as standard.

Table PTAC/UH-31-B— Standard Units for Line Voltage ControlOrder Element Std.

kW No. Element & Motor Amp Control ShipRating UHEC 236- Phase Voltage Rating Voltage wt. lbs

031A0C0 -172 1 208 15.9 208 25031B0C0 -174 1 240/208 13.7/11.9 240/208 25

3.3 kW 032A0C0 -176 1-3 208 15.9 208 25032B0C0 -178 1-3 240/208 13.7/11.9 240/208 25031C0C0 -180 1 277 11.9 277 25051A0C0 -184 1 208 24.1 208 25051B0C0 -186 1 240/208 20.9/18.1 240/208 25

5.0 kW 052A0C0 -188 1-3 208 24.1 208 25052B0C0 -190 1-3 240/208 20.9/18.1 240/208 25051C0C0 -192 1 277 18.1 277 25

1. Supply wire must have 75°C minimum insulation.2. Transformers and Contactors are not furnished for these units.3. The control voltage is line voltage.

Electric Unit HeatersVoltage Control

Page 318: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PTAC/UH-32Effective 1/1/06

Table PTAC/UH-32-A—Production with 24V Control Voltage Transformer & ContactorOrder Element Std.

kW No. Element & Motor Amp Control ShipRating UHEC 236- Phase Voltage Rating Voltage wt. lbs

031BACA SPEC 1 240/208 13.7/11.9 24 253.3 kW 032AACA SPEC 1-3 208 15.9 24 25

032BACA SPEC 1-3 240/208 13.7/11.9 24 25051AACA SPEC 1 208 24.1 24 25

5.0 kW 051BACA SPEC 1 240/208 20.9/18.1 24 25051CACA SPEC 1 277 18.1 24 25

30 kW 303BACA SPEC 3 240/208 72.3/62.5 24 12040 kW 403AACA SPEC 3 208 111.2 24 120

503AACA SPEC 3 208 139.0 24 12050 kW 503BACA SPEC 3 240/208 120.5/104.3 24 120

1. Supply wire must have 75°C minimum insulation.2. Each Electric Unit Heater in Table PTAC/UH-32-A is provided with a factory installed Transformer and Contactor as standard for 24V control voltage.3. All 30-50 kW units are factory wired for two-stage operation as standard. To operate on two-stage, a two-stage thermostat must be ordered.4. All 30-50 kW units are equipped with two-speed motors and factory installed Speed Switches as standard.5. Use the model number to order.

Table PTAC/UH-32-B—Production Units for Line Voltage Control with ContactorOrder Element Std.

kW No. Element & Motor Amp Control ShipRating UHEC 236- Phase Voltage Rating Voltage wt. lbs

031A0CA SPEC 1 208 15.9 208 25 031B0CA SPEC 1 240/208 13.7/11.9 240/208 25

3.3 kW 032A0CA SPEC 1-3 208 15.9 208 25032B0CA SPEC 1-3 240/208 13.7/11.9 240/208 25031C0CA SPEC 1 277 11.9 277 25051A0CA SPEC 1 208 24.1 208 25051B0CA SPEC 1 240/208 20.9/18.1 240/208 25

5.0 kW 052A0CA SPEC 1-3 208 24.1 208 25052B0CA SPEC 1-3 240/208 20.9/18.1 240/208 25051C0CA SPEC 1 277 18.1 277 25

1. Supply wire must have 75°C insulation minimum.2. Transformer not provided for these units.3. Contactor provided as standard for these units.4. Use the model number to order.

Electric Unit HeatersVoltage Control

These items are not available to all distribution channels.Please contact your distributor or local sales office for moreinformation.

Contact Waco Product Support for moreinformation on these products (1-888-872-6335)

Page 319: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PTAC/UH-33 Effective 1/1/06

Table1 PTAC/UH-33-A— Field Installed Control Options (See Tables PTAC/UH-33-A, PTAC/UH-33-B,PTAC/UH-34-A for Control Prices)Unit Thermostat Louver

Mounted Summer w/Summer ConeDisconnect Fan Fan Stratification Mounting Diffuser

Unit Switch Thermostats Switches Switch Thermostat Brackets 7.50-50 kWOrder Single- Three- Unit Wall Unit Wall Wall Unit Wall vert

Number Phase Phase MTD2 MTD MTD MTD MTD MTD MTD vert horiz only236-172 -700* NA -705* -714* -711* -719 NA -710* -718 -726* -723* NA

174 -700* NA -705* -714* -711* -719 NA -710* -718 -726* -723* NA 246 700* NA 705* 716* 711* -720 NA 710* 718 726* 723* NA 176 -700* -701* -7053* -7147* -711* -719 NA -710* -718 -726* -723* NA 178 -700* -701* -7053* -7147* -711* -719 NA -710* -718 -726* -723* NA 180 -700* NA -705* -714* -711* -719 NA -NA -718 -726* -723* NA 248 -700* NA -705* -716* -711* -720* NA -710* -718 -726* -723* NA 182 NA -701* -705* -716* -712* -720* -721 -709 NA -726* -723* NA236-184 -700* NA -705* -714* -711* -719 NA -710* -718 -726* -723* NA 250 -700* -701* -7053* -716* -711* 719 NA -710* -718 -726* -723* NA 186 -700* NA -705* -714* -711* -719 NA -710* -718 -726* -723* NA 188 -700* -701* -7053* -7147* -711* -719 NA -710* -718 -726* -723* NA 190 -700* -701* -7053* -7147* -711* -719 NA -710* -718 -726* -723* NA 252 -700* -701 -7053* -716* -711* 719 NA -710* -718 -726* -723* NA 192 -700* NA -705* -714* -711* -719 NA NA -718 -726* -723* NA 194 NA -701* -705* -716* -712* -720* -721 -709 NA -726* -723* NA 236-196 -703 -704 -705* -716* -711* 719 -721 -710* -718 -727* -724* -920* 198 -703 -702* -705* -716* -711* 719 -721 -710* -718 -727* -724* -920* 200 -703 — -705* -716* -711* 719 -721 -NA -718 -727* -724* -920* 202 NA -701* -705* -716* -712* -720* -721 -709 NA -727* -724* -920*236-204 -703 -702* -705* -716* -711* 719 -721 -710* -718 -727* -724* -920* 206 -703 -702* -705* -716* -711* 719 -721 -710* -718 -727* -724* -920* 208 -703 NA -705* -716* -711* 719 -721 -NA -718 -727* -724* -920* 210 NA -701* -705* -716* -712* -720* -721 -709 NA -727* -724* -920*236-212 NA -704 -705* -716* -711* 719 -721 -710* -718 -727* -724* -920* 214 NA -704 -705* -716* -711* 719 -721 -710* -718 -727* -724* -920* 216 NA -701* -705* -716* -712* -720* -721 -709 NA -727* -724* -920*236-218 NA -704 -705* -716* -711* 719 -721 -710* -718 -727* -724* -920* 220 NA -702* -705* -716* -712* -720* -721 -709 NA -727* -724* -920*236-222 NA NA -7054* -7165* -711* 719 -7216 -710* -718 -728* -725* -922* 224 NA -704 -7054* -7165* -711* 719 -7216 -710* -718 -728* -725* -922* 226 NA -702* -7054* -7165* -712* -720* -7216 -709 NA -728* -725* -922*236-228 NA NA -7054* -7165* -711* 719 -7216 -710* -718 -728* -725* -922* 232 NA -704 -7054* -7165* -712* -720* -7216 -709 NA -728* -725* -922* 236 NA NA -7054* -7165* -711* 719 -7216 -710* -718 -728* -725* -922* 238 NA -704 -7054* -7165* -712* -720* -7216 -709 NA -728* -725* -922*236-244 NA -704 -7054* -7165* -712 -720* -7216 -709 NA -728* -725* -922*

Notes:1. Three-phase electric unit heaters need two-pole thermostats for line voltage service.2. Unit mounted controls are always field installed by others.3. For three-phase operation use 236-706.4. For two-stage operation use 236-708.5. For two-stage operation use 236-717.6. For two-stage operation use 236-722.7. For three-phase operation use 236-715.

Electric Unit HeatersControl Options(Field Installed)

These items are not available to all distribution channels.Please contact your distributor or local sales office for moreinformation.

Contact Waco Product Support for moreinformation on these products (1-888-872-6335)

Page 320: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PTAC/UH-34Effective 1/1/06

Table PTAC/UH-34-A— Control Options (Unit Mounted in Field)Model No. Order No. Description

Power Disconnect Switch (Unit Mounted)1

DCS 252 236-700 2 Pole 25 Amp 120-277 VAC Res.DCS 253 236-701 3 Pole 25 Amp 120-600 VAC Res.DCS 323 236-702 3 Pole 32 Amp 120-600 VAC Res.DCS 632 236-703 2 Pole 63 Amp 120-600 VAC Res.DCS 633 236-704 3 Pole 63 Amp 120-600 VAC Res.

Line Voltage Thermostats (Unit Mounted)T5100 236-705 SPST 25 Amp 120-277V 45 - 90°F2

T5102 236-706 DPST 25 Amp 120-277V 45 - 90°F3

Low Voltage Thermostats 24VT5100R 236-705 SPST Low Voltage 24V 45 - 90°F (3-20 kW units) (single-stage)T5122 236-708 Two-stage Low Voltage 24V 45 - 90°F (25-50 kW units)

Stratification Thermostat4

TC5102 236-709 SPST Low Volt-Pilot 24V Duty (w/relay) 70 - 130°F5

TC5103 236-710 SPST Line Voltage 120/277V 70 - 130°F6

Summer Fan SwitchFS5101 236-711 SPST Line Voltage 120-277VFS5102 236-712 SPST Line Voltage 120-600V

Notes:1. Use two pole disconnect switch only for single-phase operation and a three pole disconnect switch only for three-phase operation. Both are factory installed.2. Ok for single or three-phase.3. Must be used on dual (single to three-phase) units when three-phase is required. Ok to use on single or three-phase units.4. Wall thermostat must be used when unit mounted stratification thermostat is required. The stratification thermostat activates the fan only for heat recovery.5. To be used on 480V three-phase units only. Not available for 277V single-phase units.6. Not available for 480V three-phase and 277V single-phase units only.

Table PTAC/UH-34-B— Control Options (Wall Mounted)Model No. Order No. Description

Line Voltage ThermostatsTW1510 236-714 SPST 30 amp 120-240V 25 Amp 277V 40 - 90°F1

TW1512 236-715 DPST 30 amp 120-240V 25 Amp 277V 40 - 90°F2

Low Voltage ThermostatA6176 236-716 SPST 24V 50 - 80°F TW123 236-717 Two-stage 24V 45 - 85°F (25-50 kW units)

Stratification ThermostatTC1602 236-718 SPST Line Voltage 120-240V 70 - 140°F3

Summer Fan SwitchFSW5111 236-719 SPST Line Voltage 120-600V FSW5112 236-720 SPST Low Voltage w/relay 24V

Low Voltage T’stat w/Summer Fan SwitchTFS5101 236-721 SPST Low Voltage 40 - 90°F4 , 6

TFS5102 236-722 Two-stage Low Voltage 45 - 85°F 24V5

1. Must be used on single-phase units only.2. Ok for use on single or three-phase units.3. Do not use with 480V three-phase units only.4. Not available for 3.3 and 5.0 kW, 208/1, 277/1, 240/208/1, 208/1-3 units must have transformer and contactor to be ok and 240/208/1-3V/phase units. Ok for use on 3.3 and 5.0 480/3 volt/

phase units. All 7.5 thru 50 kW size units, volts and phase units are ok.5. For use on 25 - 50 kW size units only.6. Comes with a relay as standard, can be factory installed if shown on the order.

These items are not available to all distribution channels.Please contact your distributor or local sales office for moreinformation.

Contact Waco Product Support for moreinformation on these products (1-888-872-6335)

Electric Unit HeatersControl Options(Field Installed)

Page 321: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PTAC/UH-35 Effective 1/1/06

Table PTAC/UH-35-A—AccessoriesModel No. Order No. Description wt. lbs.

Wall/Ceiling Mounting Bracket (horiz. discharge)A5105 236-723 2-5 kW Bracket 6.0A5120 236-724 7-20 kW Bracket 9.0 A5150 236-725 25-50 kW Bracket 11.0

Dust Shield (horiz. discharge)DS5105 233-740 3.3-5 kW Dust Shield .5 DS5120 233-741 7.5-20 kW Dust Shield .5 DS5150 233-742 25-50 kW Dust Shield .5

Ceiling Mtg. Bracket (vert. discharge)V5105 236-726 2-5 kW Bracket 9.0V5120 236-727 7-20 kW Bracket 13.0V5150 236-728 25-50 kW Bracket 13.0

Louver Cone Diffusers (vert. discharge only)RD5120 236-920 7-20 kW Diffuser 8.0RD5150 236-922 25-50 kW Diffuser 12.0

Anemostat Diffusers (vert. discharge only)AD5120 233-730 7-20 kW ANEMOSTAT 9.0AD5150 233-731 25-50 kW ANEMOSTAT 13.0

Table PTAC/UH-35-B—OSHA Fan Guards

OFG5101 233-930 3-5 kW OFG5102 233-932 7-20 kWOFG5103 233-935 25-50 kW

These items are not available to all distribution channels.Please contact your distributor or local sales office for moreinformation.

Contact Waco Product Support for moreinformation on these products (1-888-872-6335)

Electric Unit HeatersAccessories

Page 322: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PTAC/UH-36Effective 1/1/06

Table PTAC/UH-36-A— Hose Down Corrosion Resistant Unit Heaters kW Order No. Element & Ship

Rating UHRA 233 Element Phase Motor Voltage Amp Rating wt. lbs031AAAT -600 1 208 15.9033AAAT -602 3 208 9.2031GAAT -603 1 240 13.8

3.3 kW 033GAAT -604 3 240 8.0 45031CAAT -606 1 277 12.0033DAAT -608 3 480 4.0033FAAT -609 3 600 3.2051AAAT -610 1 208 24.1053AAAT -612 3 208 13.9051GAAT -614 1 240 20.9

5.0 kW 053GAAT -615 3 240 12.1 45051CAAT -616 1 277 18.1053DAAT -617 3 480 6.1053FAAT -618 3 600 4.9071AAAT -620 1 208 36.1073AAAT -621 3 208 20.9071GAAT -623 1 240 31.3

7.5 kW 073GAAT -625 3 240 18.1 45071CAAT -626 1 277 27.1073DAAT -627 3 480 9.1073FAAT -629 3 600 7.3101AAAT -631 1 208 48.1103AAAT -633 3 208 27.8101GAAT -634 1 240 41.7

10 kW 103GAAT -635 3 240 24.1 55101CAAT -637 1 277 36.2103DAAT -638 3 480 12.1103FAAT -639 3 600 9.7151AAAT -651 1 208 72.2153AAAT -653 3 208 41.7151GAAT -654 1 240 62.5

15 kW 153GAAT -655 3 240 36.2 55153DAAT -658 3 480 18.1153FAAT -659 3 600 14.5203AAAT -660 3 208 55.6

20 kW 203GAAT -662 3 240 48.2 85203DAAT -664 3 480 24.1203FAAT -666 3 600 19.3253AAAT -661 3 208 69.5

25 kW 253GAAT -663 3 240 60.3 85253DAAT -665 3 480 30.2253FAAT -667 3 600 24.1303AAAT -670 3 208 83.4

30 kW 303GAAT -672 3 240 72.3 85303DAAT -673 3 480 36.2303FAAT -674 3 600 29.0

40 kW 403DAAT -677 3 480 48.2 130403FAAT -678 3 600 38.6

48 kW 483DAAT -685 3 480 57.9 130483FAAT -687 3 600 46.3

1. Includes as standard the following controls factory installed and wired. (24V transformer, pilot light, thermostat, heat- off-fan switch, fan delay relay and disconnect.)2. Corrosion-resistant in high humidity and water-saturated areas in non-hazardous locations and atmospheres.3. 15 kW, 277V single-phase heaters are not available.

These items are not available to all distribution channels.Please contact your distributor or local sales office for moreinformation.

Contact Waco Product Support for moreinformation on these products (1-888-872-6335)

Electric Unit HeatersHose Down Corrosion Resistant

Page 323: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PTAC/UH-37 Effective 1/1/06

Table PTAC/UH-37-A— AccessoriesModel No. Order No. Description wt. lbs.

Wall Mounting KitA5520 233-690 3.3-15 kW Bracket1

W5520 233-691 3.3-15 kW Bracket2 28W5550 233-692 20-48 kW Bracket2

Ceiling Mtg. Kit3

H5550 233-694 3.3-48 kW Hanging Bracket. 6Pipe Mtg. Kit4

P5520 233-695 3.3-15 kW BracketP5550 233-696 20-48 kW Bracket 39

1. One piece bracket for wall mounting for sizes 3.3-15 kW only. Manufactured from stainless steel and epoxy coated.2. Contains wall bracket and mounting arm, ideal for use in buildings that have substantial walls. Arm only can also be bolted directly to structural steel. Manufactured from cast iron steel and

epoxy coated.3. Requires Roof or Ceiling Structure. ½” pipe, cut and threaded is required furnished by others.4. 3 ½” pipe 4” O.D. supplied by others.

These items are not available to all distribution channels.Please contact your distributor or local sales office for moreinformation.

Contact Waco Product Support for moreinformation on these products (1-888-872-6335)

Electric Unit HeatersAccessories

Page 324: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PTAC/UH-38Effective 1/1/06

Table PTAC/UH-38-A— UHXA with 24V Control Voltage 1

kW Order No. Element + Mtr Amp ControlRating UHXA 233- Volts/Phase Rating Voltage wt. lbs.

031A1B -110 208/1 16.3 24 167033A1B -112 208/3 9.8 24 167

3 kW 031B1B -114 240/1 14.8 24 167033B1B -116 240/3 8.6 24 167033D1B -118 480/3 4.3 24 167033F1B -119 600/3 3.5 24 167051A1B -120 208/1 26.0 24 167053A1B -122 208/3 15.4 24 167

5 kW 051B1B -124 240/1 23.1 24 167053B1B -126 240/3 13.4 24 167053D1B -128 480/3 6.7 24 167053F1B -129 600/3 5.4 24 167071A1B -130 208/1 38.0 24 167073A1B -132 208/3 22.3 24 167

7.5 kW 071B1B -134 240/1 33.6 24 167073B1B -136 240/3 19.4 24 167073D1B -138 480/3 9.7 24 167073F1B -139 600/3 7.8 24 167103A1B -140 208/3 29.3 24 193101B1B -142 240/1 44.0 24 193

10 kW 103B1B -144 240/3 25.5 24 193103D1B -146 480/3 12.7 24 193103F1B -148 600/3 10.2 24 193153A1B -150 208/3 43.5 24 225

15 kW 153B1B -151 240/3 38.1 24 225153D1B -152 480/3 19.0 24 225153F1B -153 600/3 15.2 24 225

20 kW 203D1B -154 480/3 25.1 24 225203F1B -155 600/3 20.0 24 225

25 kW 253D1B -156 480/3 31.1 24 225253F1B -157 600/3 24.9 24 225

*Supply conductors must be suitable for 90°C1. 24V control voltage is standard and includes built-in contactor and 24V control transformer.

Table PTAC/UH-38-B— UHXA with 120V Control Voltage kW Order No. Element + Mtr Amp Control

Rating UHXA 233- Volts/Phase Rating Voltage wt. lbs.031A2B -111 208/1 16.3 120 167033A2B -113 208/3 9.8 120 167

3 kW 031B2B -115 240/1 14.8 120 167033B2B -117 240/3 8.6 120 167033D2B -121 480/3 4.3 120 167051A2B -125 208/1 26.0 120 167053A2B -127 208/3 15.4 120 167

5 kW 051B2B -131 240/1 23.1 120 167053B2B -133 240/3 13.4 120 167053D2B -135 480/3 6.7 120 167071A2B -141 208/1 38.0 120 167073A2B -143 208/3 22.3 120 167

7 kW 071B2B -145 240/1 33.6 120 167073B2B -147 240/3 19.4 120 167073D2B -149 480/3 9.7 120 167103A2B -159 208/3 29.3 120 193101B2B -160 240/1 44.0 120 193

10 kW 103B2B -161 240/3 25.5 120 193103D2B -162 480/3 12.7 120 193153A2B -164 208/3 43.5 120 225

15 kW 153B2B -165 240/3 38.1 120 225153D2B -166 480/3 19.0 120 225

20 kW 203D2B -168 480/3 25.1 120 22525 kW 253D2B -170 480/3 31.1 120 225

* Supply conductors must be suitable for 90°C1. 120V control voltage is standard and includes built-in contactor and 120V control transformer.2. Not available for 600V heaters.

These items are not available to all distribution channels.Please contact your distributor or local sales office for moreinformation.

Contact Waco Product Support for moreinformation on these products (1-888-872-6335)

Electric Unit HeatersUHXA

Page 325: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PTAC/UH-39 Effective 1/1/06

Table PTAC/UH-39-A—UHXA with 208 or 240 Volt Control Voltage kW Order No. Element + Mtr Amp Control

Rating UHXA 233- Volts/Phase Rating Voltage wt. lbs.031A3B -260 208/1 16.3 208 167033A3B -262 208/3 9.8 208 167

3 kW 031B4B -264 240/1 14.8 240 167033B4B -266 240/3 8.6 240 167051A3B -268 208/1 26.0 208 167053A3B -270 208/3 15.4 208 167

5 kW 051B4B -272 240/1 23.1 240 167053B4B -274 240/3 13.4 240 167071A3B -276 208/1 38.0 208 167073A3B -278 208/3 22.3 208 167

7 kW 071B4B -280 240/1 33.6 240 167073B4B -282 240/3 19.4 240 167103A3B -284 208/3 29.3 208 193

10 kW 101B4B -286 240/1 44.0 240 193103B4B -288 240/3 25.5 240 193153A3B -290 208/3 43.5 208 225

15 kW 153B4B -292 240/3 38.1 240 225* Supply conductors must be suitable for 90°C1. Not available for 480 and 600 volt heaters.

Table PTAC/UH-39-B—Unit Mounted Control Option (Factory Installed)Model No. Order No. Description

Unit Mounted ThermostatT 233-010 Explosion Proof 45-90°F

1. Will operate on all voltages.

Table PTAC/UH-39-C—Wall Mounted Control OptionModel No. Order No. Description wt. lbs.TW161 233-015 Explosion Proof Thermostat SPST 40-90°F 22 Amps, 5

125-277 VAC ¾ HP @ 125 VAC, 1½ HP @ 250-277 VAC*TW162 233-019 Explosion Proof Thermostat DPST 40-90°F 22 Amps, 5

125-277 VAC ¾ HP @ 125 VAC, 1½ HP @ 250-277 VAC** Makes on fall in the temperature.

OK for use on units with 24V and 120V control voltage.

Table PTAC/UH-39-D—Mounting Bracket KitsModel No. Order No. Description wt. lbs.

Wall Mounting Bracket1

HLWM37 233-020 3, 5 and 7.5 kW Bracket 27HLWM10 233-022 10 kW Bracket 28HLWM1525 233-026 15, 20 and 25 kW Bracket 29

Ceiling Mounting Bracket2

HLHM 233-033 All Sizes 5Floor Mounting Bracket 3

HLPM37 233-041 3, 5 and 7.5 kW Bracket 37HLPM10 233-044 10 kW Bracket 38HLPM1525 233-049 15, 20 and 25 kW Bracket 40

1. Wall Bracket, ideal for use in buildings that have substantial walls. Note: The arm only can be bolted directly to structural steel.2. Ceiling Mounting Bracket - Must have adequate overhead structure to mount to. Note: ½” pipe, cut and threaded and supplied by others is required.3. Floor Mounting Bracket should be used in buildings with insufficient strength to use other types of mounting brackets.

To be used with 3½” schedule 40 pipe (4 OD supplied by others).

These items are not available to all distribution channels.Please contact your distributor or local sales office for moreinformation.

Contact Waco Product Support for moreinformation on these products (1-888-872-6335)

Electric Unit HeatersUHXA Control Options MountingBracket Kits

Page 326: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PTAC/UH-40Effective 1/1/06

Table PTAC/UH-40-A—Series 70 Electric Ceiling Surface HeaterskW Order No. Element + Element Mounting Amp

Rating UHCA 233- Motor Voltage Phase Application Rating021A7A -300 208 1 Surface 9.6

2 kW 021B7A -302 240 1 Surface 8.3021C7A -304 277 1 Surface 7.2031A7A -306 208 1 Surface 14.4

3 kW 031B7A -308 240 1 Surface 12.5031C7A -310 277 1 Surface 10.8041A7A -312 208 1 Surface 19.2041B7A -314 240 1 Surface 16.7

4 kW 041C7A -316 277 1 Surface 14.4043A7A -318 208 3 Surface 11.1043B7A -320 240 3 Surface 9.6051A7A -322 208 1 Surface 24.1051B7A -324 240 1 Surface 20.8

5 kW 051C7A -326 277 1 Surface 18.1053A7A -328 208 3 Surface 13.9053B7A -330 240 3 Surface 12.1

Surface Mounted Ceiling Heaters — Series 70 designed to be mounted to standard 4 inch ceiling box furnished and installed by others. Approximate weight 32 lbs. Packed and shipped ascomplete unit.

Table PTAC/UH-40-B—Series 80 Electric Ceiling Recessed HeaterskW Order No. Element + Element Mounting Amp

Rating UHCA 233- Motor Voltage Phase Application Rating021A8A -331 208 1 Recessed 9.6

2 kW 021B8A -333 240 1 Recessed 8.3021C8A -335 277 1 Recessed 7.2031A8A -337 208 1 Recessed 14.4

3 kW 031B8A -339 240 1 Recessed 12.5031C8A -341 277 1 Recessed 10.8041A8A -343 208 1 Recessed 19.2041B8A -345 240 1 Recessed 16.7

4 kW 041C8A -347 277 1 Recessed 14.4043A8A -349 208 3 Recessed 11.1043B8A -351 240 3 Recessed 9.6051A8A -353 208 1 Recessed 24.1051B8A -355 240 1 Recessed 20.8

5 kW 051C8A -357 277 1 Recessed 18.1053A8A -359 208 3 Recessed 13.9053B8A -361 240 3 Recessed 12.1

Recessed Mounted Ceiling Heaters — Series 80 packed and shipped as a complete unit. Contains junction box, heater box and grille.For finished ceiling application use plaster trim which is an optional accessory. Approximate weight 35 lbs.

Table PTAC/UH-40-C—Plaster TrimModel No. Order No. Description*PT3480 233-363 Plaster Trim

*Use PT3480 plaster trim for Series 80 recessed heaters when recessed in a hard finished ceiling.

Table PTAC/UH-40-D—Line Voltage Thermostats (Wall Mounted)Model No. Order No. Description*TW148 233-301 DPST 25 AMP 120-240V, 18 Amp 277V for single-phase*TW146 233-303 DPST 25 AMP 120-240V, 18 Amp 277V, Tamper Resistant for single-phase

**TW1512 233-715 DPST 30 AMP 120-240V, 25 Amp 277V, 40-90°F for 3 PhaseTW147 233-311 SPST 25 AMP 120-240V, 18 Amp 277V, Pilot Duty for use with Remote ContactorsTW145 233-313 SPST 25 AMP 120-240V, 18 Amp 277V, Pilot Duty for use with Remote Contactors,

Tamper Resistant*For use with one unit single phase and more than one unit single-phase. Makes and breaks two poles simultaneously.**For use with one unit three phase only and more than one unit three or single-phase. Do not exceed thermostat’s rated ampacity.Makes and breaks two poles simultaneously. Three phase units with TW1512 line voltage thermostat does not need a control panel.

Table PTAC/UH-40-E—Low Voltage Thermostat (Wall Mounted)Model No. Order No. Description*A6176 236-716 Deluxe 24V, Adjustable Anticipation Positive Off Switch, Thermometer, Honeywell T87FA6280 233-323 Tamperproof Kit for A6176

*Three-phase units must have a control panel when used with a wall mounted low voltage thermostat.

These items are not available to all distribution channels.Please contact your distributor or local sales office for moreinformation.

Contact Waco Product Support for moreinformation on these products (1-888-872-6335)

Electric Unit HeatersCeiling Heaters, Plaster Trim andThermostats

Page 327: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PTAC/UH-41 Effective 1/1/06

Table PTAC/UH-41-A—Thermal Relay with Built-in Line Voltage/24V Transformer*Model No. Order No. DescriptionA6281 233-370 120, 208, 240 or 277V (Specify Voltage) SPSTA6283 233-373 120, 208, 240 or 277V (Specify Voltage) 2 Circuit

*For remote mounting only, for use with low voltage A6176 thermostat.

Table PTAC/UH-41-B—Control Panels — 24V*Model No. Order No. Primary Voltage Dimensions No. Of ContactorsAF3401-24 233-332 208AH3401-24 233-334 240 12”x12”x4 ½” 1AG3401-24 233-336 277AF3402-24 233-338 208AH3402-24 233-340 240 15”x15”x4 ½” 2AG3402-24 233-342 277AF3403-24 233-344 208AH3403-24 233-346 240 20”x20”x4 ½” 3AG3403-24 233-348 277

*For control of one or more single or three phase ceiling heaters from one 24V thermostat. Panels are in NEMA one enclosures and have one or more 30 Amp, three pole, 600 VACcontactor(s), operating voltage to control voltage transformer and transformer fusing. (User must provide separate circuit for each contactor.)

Table PTAC/UH-41-C—Control Panels — 120V*Model No. Order No. Primary Voltage Dimensions No. of ContactorsAF3401-120 233-350 208AH3401-120 233-352 240 12”x12”x4 ½” 1AG3401-120 233-354 277AF3402-120 233-356 208AH3402-120 233-358 240 15”x15”x4 ½” 2AG3402-120 233-360 277AF3403-120 233-362 208AH3403-120 233-364 240 20”x20”x4 ½” 3AG3403-120 233-366 277

*For control of one or more single or three phase ceiling heaters from one 120V thermostat. Panels are in NEMA one enclosures and have one or more 30 Amp, three pole, 600 VACcontactor(s), operating voltage to control voltage transformer and transformer fusing. (User must provide separate circuit for each contactor.)

CONTROL PANELS — 1-PHASE ELECTRIC CEILING HEATERS1 – Contactor handle 3 Units.2 – Contactors handle 6 Units.3 – Contactors handle 9 Units.

Note: Make sure you do not exceed total ampacity rating.

3-PHASE ELECTRIC CEILING HEATERS1 – Contactor handle 1 Unit.2 – Contactors handle 2 Units.3 – Contactors handle 3 Units.

Note: Make sure you do not exceed total ampacity rating.Note: Each control panel uses three pole contactors rated at 30 Amps per pole.

Table PTAC/UH-41-D—Unit Mounted Controls for Series 80 Ceiling Heaters OnlyModel No. Order No. DescriptionT2 233-382 Thermostat Double PoleS 233-383 Disconnect SwitchR1 233-385 24V Transformer/RelayR 233-387 Line Voltage RelayR2 233-389 120V Relay

1. All controls factory installed and wired on the heaters.2. Thermostats are tamperproof.3. Fan purge (off delay to dissipate residual heat on shutoff) supplied as a standard control on heaters with factory installed options.

These items are not available to all distribution channels.Please contact your distributor or local sales office for moreinformation.

Contact Waco Product Support for moreinformation on these products (1-888-872-6335)

Electric Unit HeatersThermal Relay, Control Panels

Page 328: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PTAC/UH-42Effective 1/1/06

Table PTAC/UH-42-A—Electric Wall Mounted Unit Heaters — Series 20 'Order Element

kW No. + Motor Element Ship AmpRating UHWA 233- 2 Voltage Phase Amps wt. lbs. Rating

021A2AT -400 208 1 9.6 9.62000W 021B2AT -402 240 1 8.3 41 8.3

021C2AT -404 277 1 7.2 7.2031A2AT -406 208 1 14.4 14.4

3000W 031B2AT -408 240 1 12.5 41 12.5031C2AT -410 277 1 10.8 10.8041A2AT -412 208 1 19.2 19.2041B2AT -414 240 1 16.7 16.7

4000W 041C2AT -416 277 1 14.4 41 14.4043A2AT -418 208 3 11.1 11.1043B2AT -420 240 3 9.6 9.6051A2AT -422 208 1 24.0 24.1051B2AT -424 240 1 20.8 20.8

5000W 051C2AT -426 277 1 18.0 41 18.1053A2AT -428 208 3 13.9 13.9053B2AT -430 240 3 12.0 12.1

All Sizes 3420 -440 Wall Box5 9 —1. Only contactor can be built-in on Series 20 Wall Heaters.2. Factory installed (T) thermostat is standard.3. Wall box must be ordered.

Table PTAC/UH-42-B—Electric Wall Mounted Unit Heaters without Unit Mounted ThermostatOrder Element

kW No. + Motor Element Ship AmpRating UHWA 233-2 Voltage Phase Amps wt. lbs. Rating

021A2A0 n/a 208 1 9.6 9.62000W 021B2A0 n/a 240 1 8.3 41 8.3

021C2A0 n/a 277 1 7.2 7.2031A2A0 n/a 208 1 14.4 14.4

3000W 031B2A0 n/a 240 1 12.5 41 12.5031C2A0 n/a 277 1 10.8 10.8041A2A0 n/a 208 1 19.2 19.2041B2A0 n/a 240 1 16.7 16.7

4000W 041C2A0 n/a 277 1 14.4 41 14.4043A2A0 n/a 208 3 11.1 11.1043B2A0 n/a 240 3 9.6 9.6051A2A0 n/a 208 1 24.0 24.1051B2A0 n/a 240 1 20.8 20.8

5000W 051C2A0 n/a 277 1 18.0 41 18.1053A2A0 n/a 208 3 13.9 13.9053B2A0 n/a 240 3 12.0 12.1

All Sizes 3420 233-440 Wall Box5 91. Only contactor can be built-in on Series 20 Wall Heaters.2. Wall box must be ordered.

These items are not available to all distribution channels.Please contact your distributor or local sales office for moreinformation.

Contact Waco Product Support for moreinformation on these products (1-888-872-6335)

Electric Unit HeatersElectric Wall Mounted

Page 329: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PTAC/UH-43 Effective 1/1/06

Table PTAC/UH-43-A— Electric Wall Mounted Unit Heaters — Series 50 1

Order Element kW No. + Motor Element Ship AmpRating UHWA 233-2 Voltage Phase Amps wt. lbs. Rating

021A5AT -431 208 1 9.6 9.62000W 021B5AT -433 240 1 8.3 54 8.3

021C5AT -435 277 1 7.2 7.2031A5AT -437 208 1 14.4 14.4

3000W 031B5AT -439 240 1 12.5 55 12.5031C5AT -441 277 1 10.8 10.8041A5AT -443 208 1 19.2 19.2041B5AT -445 240 1 16.7 16.7

4000W 041C5AT -447 277 1 14.4 55 14.4043A5AT -449 208 3 11.1 11.1043B5AT -451 240 3 9.6 9.6051A5AT -453 208 1 24.0 24.1051B5AT -455 240 1 20.8 20.8

5000W 051C5AT -457 277 1 18.0 55 18.1053A5AT -459 208 3 13.9 13.9053B5AT -461 240 3 12.0 12.1

All Sizes 3450 -450 Wall Box5 11 —1. If circuit breaker and/or transformers are required, the Series 50 wall heater must be ordered.2. Factory installed (T) thermostat is standard.3. Wall box must be ordered.

Table PTAC/UH-43-B— Electric Wall Mounted Unit Heaters without Unit Mounted ThermostatOrder Element

kW No. + Motor Element Ship AmpRating UHWA 233-2 Voltage Phase Amps wt. lbs. Rating

021A5A0 n/a 208 1 9.6 9.62000W 021B5A0 n/a 240 1 8.3 54 8.3

021C5A0 n/a 277 1 7.2 7.2031A5A0 n/a 208 1 14.4 14.4

3000W 031B5A0 n/a 240 1 12.5 55 12.5031C5A0 n/a 277 1 10.8 10.8041A5A0 n/a 208 1 19.2 19.2041B5A0 n/a 240 1 16.7 16.7

4000W 041C5A0 n/a 277 1 14.4 55 14.4043A5A0 n/a 208 3 11.1 11.1043B5A0 n/a 240 3 9.6 9.6051A5A0 n/a 208 1 24.0 24.1051B5A0 n/a 240 1 20.8 20.8

5000W 051C5A0 n/a 277 1 18.0 55 18.1053A5A0 n/a 208 3 13.9 13.9053B5A0 n/a 240 3 12.0 12.1

All Sizes 3450 233-450 Wall Box5 111. If circuit breaker and/or transformers are required, the Series 50 wall heater must be ordered.2. Wall box must be ordered.

Table PTAC/UH-43-C— Extension Sleeves Model No. Order No. Series Unit Description 3420EX343 233-401 20 4½” extension sleeve for full surface mtg 3420EX161 233-403 20 2” extension sleeve for semi-recess mtg 3420EX82 233-405 20 1” extension sleeve for semi-recess mtg 3450EX343 233-407 50 4½” extension sleeve for full surface mtg 3450EX161 233-409 50 2” extension sleeve for semi-recess mtg 3450EX82 233-411 50 1” extension sleeve for semi-recess mtg

1. For extending front additional 2” from finished wall. Heater recesses 2¼”.2. For extending front additional 1” from finished wall. Heater recesses 3¼”. Shipping weight for sleeves is 5 lbs.3. Must be used when heater can not be fully or semi recessed into the wall.

These items are not available to all distribution channels.Please contact your distributor or local sales office for moreinformation.

Contact Waco Product Support for moreinformation on these products (1-888-872-6335)

Electric Unit HeatersElectric Wall Mounted andExtension Sleeves

Page 330: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PTAC/UH-44Effective 1/1/06

Table PTAC/UH-44-A— Control Options Factory InstalledModel No. OrderNo. Series Unit Description

R 233-415 20 + 50 Built-in contactor holding coil same as heater voltage. R1 233-417 20 + 50 Built-in Contactor 24V Holding Coil R2 233-419 20 + 50 Built-in Contactor 120V Holding Coil C 233-425 50 Circuit Breaker (Series 50 only) arranged to be disconnected before

removal of front with line side terminals covered for safe maintenance.Additional control circuit switch installed if required.

A11 233-427 50 Built-in control transformer (Series 50 only) 24V secondary. A21 233-429 50 Built-in control transformer (Series 50 only) 120V secondary available

on all three-phase heaters, up to 3 kW on 208V and 240V, single-phase and up to 4 kW on 277V, single-phase.

1. Contactor must be ordered with transformer.

Table PTAC/UH-44-B— Line Voltage Thermostats (Wall Mounted) Model No. Order No. Description TW1481 233-301 DPST 25 Amp 120-240V, 18 Amp 277V for single-phase TW1461 233-303 DPST 25 Amp 120-240V, 18 Amp 277V, Tamper Resistant for single-phase TW15122 233-715 DPST 30 Amp 120-240V, 25 Amp 277V, 40-90°F for three-phase TW147 233-311 SPST 25 Amp 120-240V, 18 Amp 277V, Pilot Duty for use with Remote Contactors TW145 233-313 SPST 25 Amp 120-240V, 18 Amp 277V, Pilot Duty for use with Remote Contactors,

Tamper Resistant1. For use with one unit single-phase and more than one unit single-phase. Makes and breaks two poles simultaneously.2. For use with one unit three-phase only and more than one unit three or single-phase. Do not exceed thermostats rated ampacity. Makes and breaks two poles simultaneously.

These items are not available to all distribution channels.Please contact your distributor or local sales office for moreinformation.

Contact Waco Product Support for moreinformation on these products (1-888-872-6335)

Electric Unit HeatersControl Options (Factory Installed)Line Voltage Thermostats

Page 331: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PTAC/UH-45 Effective 1/1/06

Table PTAC/UH-45-A—Electric Architectural Forced Air Wall Heater 1

Model No. Order No. Element +Motor Element kW ShipWatts UHAA2 233- 2 Voltage Phase Rating wt. lbs.

151ETAD -500 120 11500 151BTAD -512 240 1 1.5 26

151ATAD -502 208 1151CTAD -522 277 1 1.5 26021BTAD -514 240 1

2000 021ATAD -504 208 1 2.0 27021CTAD -524 277 1 2.0 27031BTAD -516 240 1

3000 031ATAD -506 208 1 3.0 29031CTAD -526 277 1 3.0 29041BTAD -518 240 1

4000 041ATAD -508 208 1 4.0 29041CTAD -528 277 1 4.0 29481BTAD -520 240 1

4800 481ATAD -510 208 1 4.8 29481CTAD -530 277 1 4.8 29

1. 3310 Wall Box is standard part of the Wall Heater.2. All Wall Heaters shipped as standard with factory installed tamperproof thermostat, fan delay and disconnect switch.

Table PTAC/UH-45-B—Suface Mounting Adapter 1

Model No. Order No. Description3320 EX 33 233-501 Surface Mounting Adapter

1. Field installed.2. Order as a separate item.

Table PTAC/UH-45-C—Day/Night Relay 1

Model No. Order No. DescriptionR 233-505 Day/Night Relay

1. Factory installed only.2. Order as a separate item.

These items are not available to all distribution channels.Please contact your distributor or local sales office for moreinformation.

Contact Waco Product Support for moreinformation on these products (1-888-872-6335)

Electric Unit HeatersWall Heater and Accessories

Page 332: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PTAC/UH-46Effective 1/1/06

Table PTAC/UH-46-A—Heater with Electric Element and Enclosurelbs.

Model No. Dimensions per ft.DBT 6” High x 3½” dp 4.0DBF 6” High x 3½” dp 4.0CB 4½” High x 25/8” dp 3.0DBCT 7” High x 5” dp 5.0DBCF 7” High x 5” dp 5.0RDBT-PD 5” High x 6” dp 5.0ASHDB 8” High 7.5

10” High 8.512” High 9.514” High x 5½” dp 10.516” High 11.518” High 12.520” High 13.5

1. Includes Heating Element, Thermal Overload, Front Panel and Back Panel.2. Model ASHDB furnished with steel front panels.

Table PTAC/UH-46-B—Maximum Watts/FootModel No. Maximum W/ft.DBT 300DBF 250CB 250DBCT 750DBCF 500RDBT-PD 300ASHDB 500

W/ft. Maximum W/ft.(Single Element Heaters) (Double Element Heaters) V/ph

125 282 120/single-phase188 376 208/single-phase250 500 240/single-phase93 438 277/single-phase141 564282 666333 750375 625

Electric Wall Fin - OrderingInformation

1. Electric wall fin units with painted enclosuresare available. Please contact St. LouisCustomer Service for more information.

2. Electric wall fin units with anodized aluminumfronts and (or) anodized aluminum outlet grillesand accessories are available. Please contactSt. Louis Customer Service for moreinformation.

3. Blank enclosure sections only with paintedsteel fronts and painted aluminum outlet grillesare available. Please contact St. LouisCustomer Service for more information.

4. Enclosure sections only with anodizedaluminum fronts and (or) anodized aluminumoutlet grilles are available on a 12 week shipcycle.

5. Color selection must be specified in the lineitem notes of the sales order.

6. Unit Lengths*

2 ft.3 ft.4 ft.5 ft.6 ft.*Cannot go beyond 10 ft. including extended enclosure.

These items are not available to all distribution channels.Please contact your distributor or local sales office for moreinformation.

Contact Waco Product Support for moreinformation on these products (1-888-872-6335)

Electric Unit HeatersElectric Wall Fin

Page 333: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PTAC/UH-47 Effective 1/1/06

Table PTAC/UH-47-A—Extended EnclosureModel No. lg lbs.230-6080 6” 1.0230-6081 12” 2.0 230-6082 18” 3.0 230-6083 24” 4.0230-6084 30” 5.0230-6085 36” 6.0230-6086 42” 7.0230-6087 48” 8.0230-6088 54” 9.0230-6089 60” 10.0 1. Extends the Enclosure lg another 6”, 12”, 18”, 24”, 30”, 36”, 42”, 48”, 54” or 60”.2. Extended Enclosure and Heater furnished as a one piece unit.3. Manufactured with solid metal grilles.4. Maximum over all Heater Length with Extended Enclosure is 15 feet for Models (DBT, DBF and CB), 12 feet for Models

(DBCT and RDBT-PD) and 10 feet for Model (ASHDB).

Table PTAC/UH-47-B—Blank Enclosure Sectionslbs.

Model No. Dimensions per ft.DBT 6” High x 3½” dp 4.0 DBF 6” High x 3½” dp 4.0CB 4½” High x 25/8” dp 3.0DBCT 7” High x 5” dp 5.0DBCF 7” High x 5” dp 5.0RDBT-PD 5” High x 6” dp 5.0 ASHDB 8” High 7.5

10” High 8.512” High 9.514” High x 5½” dp 10.516” High 11.518” High 12.520” High 13.5

1. Manufactured with solid metal grille less the electric heating element.2. Available in 1 ft. through 10 ft. lengths in 1 ft. increments.3. Can be modified for use with hydronic heating elements for Models DBT, DBF, DBCT, DBCF and ASHDB only.

Table PTAC/UH-47-C—Finish SelectionColor Ordering Number .Clear Anodized FSHP-CLEARBronze Anodized FSHP-BRONZEBlack Anodized FSHP-BLACK_ANODIvory, Gray, or Eggshell White FSHBP-E_WHITEBeige Baked Enamel1 FSHBP-BEIGEWhite Baked Enamel FSHBP-WHITEBrown Baked Enamel FSHP-BROWNBlack Baked Enamel FSHP-BLACK1. Baked Enamel Color Finish per Electric Wall Fin Color Selection Chart - FIN-S-3.2. Model ASHDB only cannot have anodized color finish.

Table PTAC/UH-47-D—Finished Back Panels - OptionalFinished Back Panel Ordering NumberClear Anodized (204R1) FSHP-CLEARBronze Anodized (313R1) FSHP-BRONZEBlack Anodized (313R1) FSHP-BLACK_ANODIvory, Gray, or Eggshell White FSHBP-E_WHITEBeige Baked Enamel FSHBP-BEIGEWhite Baked Enamel FSHBP-WHITEBrown Baked Enamel FSHP-BROWNBlack Baked Enamel FSHP-BLACK1. Finished back panels either painted or anodized in the same color as the heater are available for pedestal floor mountedheaters to be installed in front of windows and in lobbies.

These items are not available to all distribution channels.Please contact your distributor or local sales office for moreinformation.

Contact Waco Product Support for moreinformation on these products (1-888-872-6335)

Electric Unit HeatersEnclosures and Finishes

Page 334: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PTAC/UH-48Effective 1/1/06

Table PTAC/UH-48-C—Factory Built-In Controls - OptionalOrdering No. Model No. Description230-6000 ITS Single Pole Thermostat 20A 120-277 Vac1

230-6002 ITD Double Pole Thermostat 20A 120-277 Vac1

230-6005 IDS Double Pole Disconnect Switch 20A 120-277 Vac2

230-6010 ATR Transformer Relay single pole 25A 120-277 Vac3

230-6012 PR Power Relay Contactor 208/24, 208/208 18 amp4, 5

230-6014 PR Power Relay Contactor 240/24 18 amp4, 5 230-6016 PR Power Relay Contactor 277/24, 277/277 18 amp4, 5

1. Factory mounted and wired in left hand junction box, adjustable thru discharge grille.2. Factory mounted and wired in left hand junction box, adjustable thru discharge grille.3. Rated 25 Amp 120-277 VAC contacts rated up thru 277V and must be specified. Coils are 24V and 120V and must be specified. Requires 6” or 12” Control Sections for mounting which

will lengthen the heater dimensions. 12” Extended Enclosures must be used.4. Requires 6” or 12” Control Sections for mounting which will lengthen the heater dimensions. 12” Extended Enclosures must be used.5. Standard Contactor with 18 Amp contacts and coil voltage of 24V or same as primary voltage of the heater as specified.

TTable PTAC/UH-48-D—Control SectionsOrdering No. Model No. Description230-6030 CS6 6” Control Section1

230-6033 CS12 12” Control Section2

1. For factory mounting of 1 or 2 controls. Right or left side mounting available with right side being standard. Requires 12” Extended Enclosure for installation. Control Sections must be fieldwired to the heater.

2. For factory mounting of 1, 2 or 3 controls. Right or left side mounting available with right side being standard. Requires 12” Extended Enclosure for installation. Control Sections must befield wired to the heater.

Table PTAC/UH-48-E—Inside CornersModel No. Ordering No.DBT-ICDBF-IC 230-6040CB-ICDBCT-IC 230-6044DBCF-ICRDBT-PD-IC 230-6046 ASHDB-IC 8”-20” 230-60481. Inside Corners 90 - 180° furnished as standard.

Table PTAC/UH-48-F—Outside CornersModel No. Ordering No.DBT-OCDBF-OC 230-6050CB-OC DBCT-OC 230-6054DBCF-OCRDBT-PD-OC 230-6056ASHDB-OC 8”-20” 230-60581. Outside Corners 180 - 270° furnished as standard.

Table PTAC/UH-48-A—¼” Wire Mesh - Optional

1/4” Wire Mesh1. Factory installed under grille on enclosure or Blank Enclosure Sections and Extended Enclosure Sections with open

grilles.

Table PTAC/UH-48-B—Pedestal Brackets - OptionalOrdering No.230-6020 ASB PD Pedestals1. For floor mounting of all Model Heaters. Must be ordered separately.2. Pedestal brackets are available for floor mounting in lobbies and in front of windows for all models except ASHDB 10”,

12”, 14”, 18” and 20” high heaters. Factory installed to the bottom of the unit for field furnished power wiring to be runthrough the center of the pedestal into the bottom of the units junction box for connection to the heater. The knockouts thatare provided in the side and rear of each heaters junction box and the back panel mounting holes for wall mounting ofunits are not furnished when pedestals are ordered. 2’ to 6’ heaters require two pedestals, 6’ to 8’ heaters require threepedestals, 9’ and 10’ heaters require four pedestals.

These items are not available to all distribution channels.Please contact your distributor or local sales office for moreinformation.

Contact Waco Product Support for moreinformation on these products (1-888-872-6335)

Electric Unit HeatersElectric Wall Fin Accessories

Page 335: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

PTAC/UH-49 Effective 1/1/06

Table PTAC/UH-49-A—LH and RH End CapsModel No. Ordering No.DBT-ECDBF-EC LH - 230-6051CB-EC RH - 230-6055DBCT-ECDBCF-ECASHDB-EC LH - 230-6053

RH - 230-6059RDBT-EC LH-PDIEC

RDBT-EL RH-PDIEC1. Specify Left or Right hand.2. To cap off each end of the heater for a finished look.

Table PTAC/UH-49-B—2” Wall TrimsModel No. Ordering No.DBT-WT_DBF-WT_ 230-6062CB-WT_DBCT-WT_ 230-6063DBCF-WT_ASHDB-WT_ 230-60651. Extends the end of the heater to the wall or column.

Table PTAC/UH-49-C—6” Wall TrimsModel No. Ordering No.DBT-WT_DBF-WT_ 230-6061CB-WT_DBCT-WT_ 230-6067DBCF-WT_ASHDB-WT_ 230-60681. Extends the end of the heater to the wall or column.

Table PTAC/UH-49-D—1½” Splice PlateModel No. Ordering No.DBT-SPDBF-SP 230-6060CB-SPDBCT-SP 230-6064DBCF-SPASHDB-SP 230-60661. Conceals gap between two heaters or blank sections.

Table PTAC/UH-49-E—Accessories for Mounting Hydronic Heating ElementsItem Ordering No.Rod Hangers 230-6070Slide Cradle Brackets 230-6071 6” Valve Compartment Blank Sections 230-6072

12” Valve Compartment Blank Sections 230-60741. Order qty. 2 Rod Hangers or Slide Cradle Brackets for 2' - 5' lengths, qty. 3 for 6' - 8' lengths and qty. 4 for 9' - 10' lengths.

Table PTAC/UH-49-F—Wall Mounted Controls — OptionalModel No. Order No. DescriptionTW241 230-006 SPST Wall Mounted Line Voltage Thermostat, 40-90°F, 250 VA2

TW242 230-007 DPST Wall Mounted Line Voltage Thermostat, 40-90°F, 250 VA2

MB-120 230-009 Wall Mounted Low Voltage Thermostat, 50-90°F, 24V A62811 233-370 Remote Mounted Thermal Relay with Built-In Line Voltage/24V

Transformer. 120, 208, 240 or 277V SPST 25 Amp1. Specify voltage on the sales order.2. Electrical rating and W — 120V - 2600W, 208V - 4500W, 240V - 5200W and 277V - 4900W.

These items are not available to all distribution channels.Please contact your distributor or local sales office for moreinformation.

Contact Waco Product Support for moreinformation on these products (1-888-872-6335)

Electric Unit HeatersElectric Wall Fin Accessories

Page 336: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

WA-1 Effective 1/1/06

Dealer/Seller’s Signature* Date

Equipment Owner’s Signature Date

Dealer/Seller

Dealer/Seller #

Name ____________________________________

Address __________________________________

City, State, Zip ____________________________

Telephone # ( ______ ) _____________________

Servicer (if other than Dealer/Seller)

Servicer #

Name ____________________________________

Address __________________________________

City, State, Zip ____________________________

Telephone # ( ______ ) _____________________

Warranty Model # A RAWY *Not used on somewarranty model numbers.

Completed by Distributor Only

Bill to #

Name ______________________________________________

Approved By _______________________________________

Purchasers P.O. # ____________________________________(If Desired)

EQUIPMENT Note: Use separate applications for each required agreement.COVERED MODEL # – use 1st 11 digits SERIAL # Date Equipment Installed ___________________

___________________ _________________________ __________________________Required

___________________ _________________________ __________________________ Date Warranty Sold ___________________

___________________ _________________________ __________________________By Dealer

___________________ _________________________ __________________________ Warranty Sales Price $ __________________

If the Equipment Covered is a Compressor Only – What is the Condensing Unit Model # ___________________________________

What is the Condensing Unit Serial # ___________________________________

EQUIPMENT OWNER: (Mailing Address)

Name

Address

City State Zip (Required)

( ) Telephone

EQUIPMENT LOCATION: (If Different)

Name

Address

City State Zip (Required)

Servicer Labor Option: 1 2 3 (Circle One)

Is this warranty a renewal of an existing Extended Warranty? Yes No

If yes, what is the agreement number of the old warranty .

EXTENDED WARRANTY APPLICATION

For Extended Warranty Dept. Use Only

Agreement No. __________________________________

Rec’d. Date: __________________________________

This Document is an Application Only. The Extended Warranty will become effective when accepted byThe Trane Company. The Trane Company will notify the Equipment Owner by sending the Extended WarrantyAgreement that provides coverage for the Extended Warranty Model listed above. If you do not receive aconfirming agreement from Trane within 45 days, please call 800-554-6413.

As the Equipment Owner, I acknowledge that I haveread and understand the “Terms and Conditions” as wellas the type of coverage and length of coverage of theTrane Extended Warranty for which I have applied.

UNITARYPRODUCTS GROUP

* Dealer/Seller’s signature indicates equipment over 9 months old has been inspected and is in good working condition.Inspection not required if equipment is less than 9 months old or if this is a renewal of an existing extended warranty.

DEALER INSTRUCTIONS: Send To Your Distributor For Processing.

Pub. No. 26-1021-06 (12/00)

PROM

O STA

MP

IF APPLIC

ABLE

T

Product Application: ■ Residential ■ CommercialEquipment Covered: ■ System ■ Condensing Unit ■ Furnace/Air Handler ■ Compressor Only ■ Other ______________Length of Coverage: ■ 1 Year ■ 5 Years ■ 10 Years ■ 15 Years ■ 20 YearsType of Coverage: ■ Parts Only ■ Labor Only ■ Both Parts and LaborNote: Not all combinations of above are available. The warranty model number listed above must agree with selections.

Extended Warranty Labor Options

Labor Options provide more flexibility forthe dealer and are selected at the time ofsale. These options determine how longa dealer has to guarantee his labor, andestablish the set of “Servicer Guideline”rates that can be used when makingclaims. The options are as follows:

Labor Option #1:Trane’s Optional Extended Warranty isresponsible for labor beginning theninety-first (91st) day from the dateof installation or the date activated,whichever is later. The dealer is respon-sible for the labor through the first ninety(90) days.

Labor Option #2:Trane’s Optional Extended Warranty isresponsible for labor beginning one (1)year from the date of installation. Thedealer is responsible for the laborthrough the first (1st) year. Labor Option#2 is not available on equipment over 9months old or on "Parts Only" OptionalExtended Warranties.

Labor Option #3:Trane’s Optional Extended Warranty isresponsible for labor beginning theninety-first (91st) day from the date ofinstallation or the date activated,whichever is later. The dealer is respon-sible for labor through the first ninety(90) days.Coverage for Labor Option #3 will costmore than the other two options. If itis chosen, the Trane Optional ExtendedWarranty Agreement will automaticallybe assigned the letter “X” to the end ofthe model number. (Example:TAYWAR0004 that contains LaborOption #3 will become TAYWAR0004X).To determine the exact cost of an TraneOptional Extended Warranty thatcontains Labor Option #3, refer to theprice book and select the model numberthat contains the letter “X”at the end of the model number. It is notnecessary to indicate the“X” in the model number whencompleting an application.

Labor options are chosen at the time an application is completed using the three(3) selection blocks on the application form (see above). The dealer simply marksthe option chosen. When the application is activated, that agreement will always beassociated with that Labor Option. If no option is chosen, then option #1 willautomatically be selected.

Refer to the Trane Optional Extended Warranty Handbook for additional information(Pub. No. 26-1019).

The “Servicer Guideline Rates” forlabor options #1, #2, and #3 areused when submitted claims andare noted on page WA-2 and WA-3.

or latest version

Great care has been taken to ensure the accuracy of the information in the Extended Warrantysection of the Residential and Light Commercial Products Handbook; however, the information inthe Trane Optional Extended Warranty handbook supersedes all information contained herein.

Page 337: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

WA-2Effective 1/1/06

Trane Optional Extended Warranty“Standard Servicer Guidelines”

These guidelines should be used when submitting claims on “Trane Extended Warranty” agreements - Standard or Labor Option #1.

1. ALLOWABLE LABOR RATES ———————— Dealer’s standard hourly rate.

2. PARTS MARK UP ALLOWANCE (Used for out-of-warranty parts)$0.01 - 4.99 = Dealer Cost + $5.00$5.00 - 24.99 = Dealer Cost x 2.0

$25.00 - 49.99 = Dealer Cost x 1.7$50.00 - 149.99 = Dealer Cost x 1.6

$150.00 - 499.99 = Dealer Cost x 1.5$500.00 - up = Dealer Cost x 1.4

Refrigerant = Dealer Cost x 2.0

IN-WARRANTY PARTS MARK UP ALLOWANCE (Used for in-Warranty Parts, years 2-5 when equipment has 5-year parts Manufacturer’s Limited Warranty. Does not apply tocompressor, outdoor coil, or heat exchanger. If a non-Trane part is purchased during the Manufacturer’s Limited Warranty period, dealer will be reimbursed cost of part only,maximum $10.00)

Labor Option #1$0.01 - 4.99 = Dealer’s Normal Purchase Price, $5.00$5.00 - 24.99 = Dealer’s Normal Purchase Price x 1.0

$25.00 - 49.99 = Dealer’s Normal Purchase Price x 0.7$50.00 - 149.99 = Dealer’s Normal Purchase Price x 0.6

$150.00 - 499.99 = Dealer’s Normal Purchase Price x 0.5$500.00 - up = Dealer’s Normal Purchase Price x 0.4

3. REPAIR/REPLACE TIME — The hours provided below constitute the maximum number of hours that may be claimed. If your actual repair or replacement time is lessthan the amounts specified below, or as described in this paragrah, your actual time must be reported. For multiple component replacements in the same unit, eachadditional component may receive a maximum of 0.5 hours. For any component not listed, it may receive a maximum of 0.5 hours. If your actual repair or replacement time isgreater than the amounts specified below, or as described in this paragraph, and you believe that additional time is justified, please explain the circumstances of the repair orreplacement in writing.

Max Hours AllowedReplacement or Repaired Item 1-5 Tons 6 1/4 - 25 TonsRefrigerant Circuit2

Refrigerant recovery (only if required) .................................................................... 1.0 2.0Compressor replacement3 .................................................................................... 4.0 6.0Condenser coil replacement ................................................................................... 4.0 6.0Evaporator coil replacement ................................................................................... 4.5 6.0Expansion valve replacement ................................................................................ 3.0 4.0Switch over valve replacement ............................................................................... 3.5 4.5Check valve replacement or service valve ............................................................. 2.0 3.0Drier replacement ................................................................................................... 1.0 1.0Schrader core ......................................................................................................... 0.5 0.5Tighten valves (caps, cores, rotolocks) .................................................................. 0.5 0.5Repairable leak in fitting, etc. (Brazing required,explain work done) ......................... 2.0 3.0

Electrical ControlsAny component replacement .................................................................................. 0.5 0.5Hard start kit ........................................................................................................... 0.5 —Thermostat (Indoor) ................................................................................................ 1.0 1.0Thermostat (Outdoor) ............................................................................................. 0.5 0.5Crankcase heater replacement .............................................................................. 0.5 0.5

Condenser Fan AssembliesFan blade replacement ........................................................................................... 0.5 0.5Motor replacement (includes fan blade, capacitor) ................................................ 1.5 1.5

Evaporator Fan AssemblyBlower wheel replacement ..................................................................................... 1.0 1.0Motor replacement (includes blower wheel, capacitor) .......................................... 1.5 1.5Replace module (includes motor) ........................................................................... 1.0 1.0Bearing replacement - each ................................................................................... 0.5 0.5Sheaves replacement - each (includes belt) .......................................................... 0.5 0.5Belt replacement ..................................................................................................... 0.5 0.5Drain pan replacement ........................................................................................... 2.0 2.0

Heating SectionAny control replacement (ignitor, sensor, ignition control, etc.) ............................. 0.5 0.5Heating element replacement ................................................................................ 1.0 1.0Combustion blower replacement ............................................................................ 1.0 1.0Gas valve replacement ........................................................................................... 1.0 1.0Heat exchanger replacement ................................................................................. 4.0 6.0Burners ................................................................................................................... 1.0 1.0

Economizer SectionAny control replacement ......................................................................................... 0.5 0.5Actuator replacement ............................................................................................. 1.0 1.0

Misc. SectionSolve noise complaint7 ......................................................................................... 0.5 0.5Diagnostic Charge1 ............................................................................................... 0.5 0.5Multiple Components .............................................................................................. 0.5 0.5

NOTES:1 Diagnostic calls will be paid only on covered repairs. (Not paid on maintenance or dirty sock)2 All times allowed requiring entry or repair to refrigerant circuit includes evacuation, recharge and drier change.3 All times allowed for compressor replacement includes drier change, cleanup, evacuation and recharge.4 Crane allowance up to $150 or 2 hrs. at a Dealer’s registered rate in lieu of crane charge is allowed on systems applied in a commercial application or if the equipment is 4

tons or greater. (Not allowed on parts only warranty.)5 Sales tax, if applicable, will be reimbursed to the dealer.6 All times not shown for specific tasks - Call 1-800-554-6413.7 Noise complaint paid only when noise due to internal component failure or malfunction. Maximum time allowed is 0.5 hrs. plus the time allowed for the component

replacement/repair. Explain fully.8 Pay only one (1) man per job.9 All invoices must be received within sixty (60) days of the repair.

TRAVEL TIME: (Flat Rate Dealers cannot charge Travel Time)24 miles or less, one way - add 1/2 hour based on your established labor rate.25 miles or greater, one way - add 1 hour based on your established labor rate.Only one (1) trip charge paid per service call.

ALL CLAIMS RELATED DECISIONS MADE BY AMERICAN STANDARD WARRANTY COMPANY ARE FINAL.

Great care has been taken to ensure the accuracy ofthe information in the Extended Warranty section ofthe Residential and Light Commercial ProductsHandbook; however, the information in the TraneOptional Extended Warranty handbook supersedesall information contained herein.

Page 338: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

WA-3 Effective 1/1/06

Trane Optional Extended Warranty“Expanded Servicer Guidelines”

These guidelines should be used when submitting claims on “Trane Optional Extended Warranty” Agreements - Labor Option #2 & #3.

1. ALLOWABLE LABOR RATES ———————— Dealer’s standard hourly rate.

2. PARTS MARK UP ALLOWANCE (Used for out-of-warranty parts)

$0.01 - 4.99 = Dealer Cost + $7.50$5.00 - 24.99 = Dealer Cost x 2.5

$25.00 - 49.99 = Dealer Cost x 2.1$50.00 - 149.99 = Dealer Cost x 1.9

$150.00 - 499.99 = Dealer Cost x 1.7$500.00 - up = Dealer Cost x 1.5

Refrigerant = Dealer Cost x 2.0

IN-WARRANTY PARTS MARK UP ALLOWANCE (Used for in-Warranty Parts, years 2-5 when equipment has 5 year parts Manufacturer’s Limited Warranty. Does not apply tocompressor, outdoor coil, or heat exchanger. If a non-Trane part is purchased during the Manufacturer’s Limited Warranty period, dealer will be reimbursed cost of part only,maximum $10.00)

Labor Option #2 and #3$0.01 - 4.99 = Dealer’s Normal Purchase Price, $7.50$5.00 - 24.99 = Dealer’s Normal Purchase Price x 1.5

$25.00 - 49.99 = Dealer’s Normal Purchase Price x 1.1$50.00 - 149.99 = Dealer’s Normal Purchase Price x 0.9

$150.00 - 499.99 = Dealer’s Normal Purchase Price x 0.7$500.00 - up = Dealer’s Normal Purchase Price x 0.5

3. REPAIR/REPLACE TIME — The hours provided below constitute the maximum number of hours that may be claimed. If your actual repair or replacement time is lessthan the amounts specified below, or as described in this paragrah, your actual time must be reported. For multiple component replacements in the same unit, eachadditional component may receive a maximum of 0.5 hours. For any component not listed, it may receive a maximum of 0.5 hours. If your actual repair or replacement time isgreater than the amounts specified below, or as described in this paragraph, and you believe that additional time is justified, please explain the circumstances of the repair orreplacement in writing.

Max Hours AllowedReplacement or Repaired Item 1-5 Tons 6 1/4 - 25 Tons

Refrigerant Circuit2Refrigerant recovery (only if required) ........................................................................... 1.0 2.0Compressor replacement3 ........................................................................................... 4.0 6.0Condenser coil replacement .......................................................................................... 4.0 6.0Evaporator coil replacement .......................................................................................... 4.5 6.0Expansion valve replacement ........................................................................................ 3.0 4.0Switch over valve replacement ...................................................................................... 3.5 4.5Check valve replacement or service valve ..................................................................... 2.0 3.0Drier replacement .......................................................................................................... 1.0 1.0Schrader core ................................................................................................................ 0.5 0.5Tighten valves (caps, cores, rotolocks) .......................................................................... 0.5 0.5Repairable leak in fitting, etc. (brazing required explain work done) ............................. 2.0 3.0

Electrical ControlsAny component replacement ......................................................................................... 0.5 0.5Hard start kit ................................................................................................................... 0.5 —Thermostat (Indoor) ....................................................................................................... 1.0 1.0Thermostat (Outdoor) .................................................................................................... 0.5 0.5Crankcase heater replacement ...................................................................................... 0.5 0.5

Condenser Fan AssembliesFan blade replacement .................................................................................................. 0.5 0.5Motor replacement (includes fan blade capacitor) ......................................................... 1.5 1.5

Evaporator Fan AssemblyBlower wheel replacement ............................................................................................. 1.0 1.0Motor replacement (includes blower wheel, capacitor) .................................................. 1.5 1.5Module replacement (includes motor) ............................................................................ 1.0 1.0Bearing replacement - each ........................................................................................... 0.5 0.5Sheaves replacement - each (includes belt) .................................................................. 0.5 0.5Belt replacement ............................................................................................................ 0.5 0.5Drain pan replacement ................................................................................................... 2.0 2.0

Heating SectionAny control replacement (ignitor, sensor, ignition control, etc.) .................................... 0.5 0.5Heating element replacement ........................................................................................ 1.0 1.0Combustion blower replacement ................................................................................... 1.0 1.0Gas valve replacement .................................................................................................. 1.0 1.0Heat exchanger replacement ......................................................................................... 4.0 6.0Burners .......................................................................................................................... 1.0 1.0

Economizer SectionAny control replacement ................................................................................................ 0.5 0.5Actuator replacement ..................................................................................................... 1.0 1.0

Misc. SectionSolve noise complaint7 ................................................................................................ 0.5 0.5Diagnostic Charge1 ...................................................................................................... 0.5 0.5Multiple Components ..................................................................................................... 0.5 0.5

NOTES: 1 Diagnostic calls will be paid only on covered repairs. (Not paid on maintenance or dirty sock)2 All times allowed requiring entry or repair to refrigerant circuit includes evacuation, recharge and drier change.3 All times allowed for compressor replacement includes drier change, cleanup, evacuation and recharge.4 Crane allowance up to $150 or 2 hrs. at a Dealer’s registered rate in lieu of crane charge is allowed on systems applied in a commercial application or if the

equipment is 4 tons or greater. (Not allowed on parts only warranty.)5 Sales tax, if applicable, will be reimbursed to the dealer.6 All times not shown for specific tasks - Call 1-800-554-6413.7 Noise complaint paid only when noise due to internal component failure or malfunction. Maximum time allowed is 0.5 hours plus the time

allowed for the component replacement/repair. Explain fully.8 Pay only one (1) man per job.9 All invoices must be received within sixty (60) days of the repair.

TRAVEL TIME (Flat Rate Dealers cannot charge Travel Time):Mileage (any distance) - add 1 hour based on your established labor rate.Two (2) trip charges are allowed for major component replacement (compressor, outdoor coil, evaporator coil, switch over valve, burners, or heat exchanger).

ALL CLAIMS RELATED DECISIONS MADE BY AMERICAN STANDARD WARRANTY COMPANY ARE FINAL.

Great care has been taken to ensure the accuracy ofthe information in the Extended Warranty section ofthe Residential and Light Commercial ProductsHandbook; however, the information in the TraneOptional Extended Warranty handbook supersedesall information contained herein.

Page 339: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

WA-4Effective 1/1/06

Optional Extended Warranty Benefits

Consumer Benefits

Peace of Mind• No unexpected out-of-pocket expenses*• Repair/Replace option allows consumer to apply repair cost toward

purchase price of new equipment• Hedge against inflation (parts, labor and refrigerant)

Assurance of Commitment• Trane dealer assigned to their agreement has up-to-date

knowledge of equipment and service techniques• Extended Warranty is transferrable to subsequent homeowners

should the original owner sell their home• Cost effective as compared to other Extended Warranties

(i.e., appliances, consumer electronics, automobiles)

Dealer Benefits• Labor Coverage after 90th Day (lower labor reserves)• Extended Warranty contracts assign selling dealer as servicer of

record which potentially “locks in” customer for the life of thewarranty

• Provides “In Warranty” parts markup (revenue opportunity)• Additional profit opportunity by selling the Extended Warranty

(gross profit becomes close to net profit)• Repair/Replace option allows consumer to apply repair costs

toward purchase price of new equipment• Dealer provides more comprehensive coverage which improves

customer satisfaction with dealer and Trane• Encourages the sale of Maintenance Agreements• Commercial Product up to 25 tons can be covered up to 10 years

for parts and labor• New construction dealer can include Extended Warranties, captur-

ing customers they normally don’t see (if agreement is put in thebuilder’s name, the agreement can be transferred to the newhomeowner at no charge)

*Covers labor, refrigerant, diagnostic, and parts, subject to product coverage and terms and conditions.

Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the Residential and LightCommercial Products Handbook; however, the information in the Trane Optional Extended Warranty handbook supersedes allinformation contained herein.

Page 340: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

WA-5 Effective 1/1/06

Optional Extended Warranty Benefits

Example:

Assumptions:• Unit is 4 years old and an Evaporator Coil must be replaced• Evaporator Coil is an in-warranty part that would normally cost $500

if purchased• Dealer has $70/hr. labor rate (time and material, not flat rate)• 7 lbs. of R410A needed for repair (dealer cost is $11/lb.)

• In the above example, even with a 10-year Limited Warranty on parts, the consumer still paid $644 for acoil replacement, and you made only $77 in profit on parts. With the Extended Warranty, the consumerpays nothing for the repair and you made an additional $250 in profit on parts

Selling Story:• The Extended Warranty should be offered at time of sale (can be

included with financing)• Use the Extended Warranty Sales Brochure, Pub. No. 26-1016 and the

consumer benefits on the reverse side• Point out that Limited Warranty does not cover refrigerant or labor• If the Extended Warranty is “included” in the total proposal, it is much easier

to sell• If you are in a “regulated” state, you must provide the actual purchase price

(not to be less than your actual cost) on the Extended Warranty Application.This amount will appear on the consumer’s agreement (see your ExtendedWarranty Handbook for more information on selling Extended Warranties in“regulated” states)

Consumer has NoConsumer has 10-Yr. P&L, Lbr. Opt. 3 Extended Warranty Difference

EW Pays Dealer Consumer Pays DealerLabor Travel (2 hrs.) $ 140.00 $ 140.00 $ -

Diagnostic (.5 hrs.) $ 35.00 $ 35.00 $ -Repair (4.5 hrs.) $ 315.00 $ 315.00 $ -Total $ 490.00 $ 490.00 $ -

Parts Coil (.5 x normal cost) $ 250.00 $ - (in-warranty part) $ 250.00R410A(2 x #lbs. x dealer cost) $ 154.00 $ 154.00 $ -

Total $ 894.00 $ 644.00 $ 250.00Profit on Parts $ 327.00 $ 77.00 $ 250.00

Great care has been taken to ensure the accuracy of the information in the Extended Warranty section ofthe Residential and Light Commercial Products Handbook; however, the information in the Trane OptionalExtended Warranty handbook supersedes all information contained herein.

Page 341: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

AC/IN-1 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Roof Curbs

BAYCURB050A FULL PERIMETER ROOF MOUNTING CURB OUTLINE

Full Perimeter BAYCURB050A Full Perimeter BAYCURB051A

4TCC3018-036A 4TCC3042-060A4TCX3018-036A 4TCX3042-060A

2/4WCC3018-036A 2/4WCC3042-060A2/4WCX3018-036A 2/4WCX3042-060A2/4YCC3018-036A 2/4YCC3042-060A2/4YCX3018-036A 2/4YCX3042-060A

BAYCURB051A FULL PERIMETER ROOF MOUNTING CURB OUTLINE

018 through 036

042 through 060

Page 342: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

AC/IN-2Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Roofcurb Adaptors

BAYADAP050A CURB ADAPTOR FOR ***018-36A TO EXISTING BAYCURB030 OR BAYCURB038

EXISTING NEW UNIT USECURB 2/4TC/WC/YC****A BAYADAP0**A

BAYCURB030,38A 018-036 50BAYCURB030,38A 042-060 52

BAYCURB033A 018-036 51BAYCURB033A 042-060 53BAYCURB034A 042-060 54

*All 15 digit model numbers starting with 2 or 4 andYCC, YCX, TCC, TCX, WCC and WCX.

Page 343: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

AC/IN-3 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Roofcurb Adaptors

BAYADAP051A CURB ADAPTOR FOR ***018-36A TO EXISTING BAYCURB033

EXISTING NEW UNIT USECURB 2/4TC/WC/YC****A BAYADAP0**A

BAYCURB030,38A 018-036 50BAYCURB030,38A 042-060 52

BAYCURB033A 018-036 51BAYCURB033A 042-060 53BAYCURB034A 042-060 54

*All 15 digit model numbers starting with 2 or 4 andYCC, YCX, TCC, TCX, WCC and WCX.

Page 344: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

AC/IN-4Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Roofcurb Adaptors

BAYADAP052A CURB ADAPTOR FOR *****042-60A TO EXISTING BAYCURB030 OR BAYCURB038

EXISTING NEW UNIT USECURB 2/4TC/WC/YC****A BAYADAP0**A

BAYCURB030,38A 018-036 50BAYCURB030,38A 042-060 52

BAYCURB033A 018-036 51BAYCURB033A 042-060 53BAYCURB034A 042-060 54

*All 15 digit model numbers starting with 2 or 4 andYCC, YCX, TCC, TCX, WCC and WCX.

Page 345: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

AC/IN-5 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Roofcurb Adaptors

BAYADAP053A CURB ADAPTOR FOR *****042-60A TO EXISTING BAYCURB030 OR BAYCURB033

EXISTING NEW UNIT USECURB 2/4TC/WC/YC****A BAYADAP0**A

BAYCURB030,38A 018-036 50BAYCURB030,38A 042-060 52

BAYCURB033A 018-036 51BAYCURB033A 042-060 53BAYCURB034A 042-060 54

SA

RA

41 7/8"56 1/8"

31"

57 21/32"“A”

“A”“B”

“B”

EXISTING CURBBAYCURB033

Weight in Lbs.

ShippingWeight

OperatingWeight

155

110

56 1/8"

ROOFVIEW “A”-”A”

10"

53 1/8" I.D.

19 1/2" I.D. 28 7/8" I.D.

61 21/32"

EXISTINGCURB

VIEW “B”-”B”

41 7/8"

EXISTINGCURB

ROOF

CC C CC C CC C

35"

38 7/8" I.D.

20" I.D.

*All 15 digit model numbers starting with 2 or 4 andYCC, YCX, TCC, TCX, WCC and WCX.

Page 346: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

AC/IN-6Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Roofcurb Adaptors

BAYADAP054A CURB ADAPTOR FOR *****042-60A TO EXISTING BAYCURB034

EXISTING NEW UNIT USECURB 2/4TC/WC/YC****A BAYADAP0**A

BAYCURB030,38A 018-036 50BAYCURB030,38A 042-060 52

BAYCURB033A 018-036 51BAYCURB033A 042-060 53BAYCURB034A 042-060 54

*All 15 digit model numbers starting with 2 or 4 andYCC, YCX, TCC, TCX, WCC and WCX.

Page 347: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

AC/IN-7 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Impack™ Roof Curbs

BAYCURB038A UNIVERSAL ROOF MOUNTING CURB OUTLINE

From Dwg. 21C662034 Rev. 2

BAYCURB030A UNIVERSAL ROOF MOUNTING CURB OUTLINE

Insul.Deck

Universal curb w/adaptations,fits all Impack models with insulated deck pans

Universal curb w/adaptations, fits all Impack models

Full Perimeter BAYCURB030A Full Perimeter BAYCURB038ATCC018-042 WCC018-042 YCC018-036M TCC018-042 WCC018-042 YCC018-036MTCP024-030 WCX024-030 YCP024-36M TCP024-030 WCX024-030 YCP024-36MTCX024-030 WCY024-030 YCX024-036M TCX024-030 WCY024-030 YCX024-036M

TCY024-030 TCY024-030

Page 348: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

AC/IN-8Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

From Dwg. 21C662034 Rev. 2

BAYCURB034A ROOF MOUNTING CURB OUTLINESUPPLY /RETURN AIR DUCT OPENINGS

BAYCURB033A ROOF MOUNTING CURB OUTLINE

Full perimeter fit curb for Impack models with insulated deck pan

Full perimeter fit curb for Impack models with insulated deck pan

Impack™ Roof Curbs

Full Perimeter BAYCURB033A Full Perimeter BAYCURB034ATCP036-042F WCP036 YCC036H,042 TCC048-060 WCC048-060 YCC048H-060

048MTCX036-042G WCX036-042G YCP036H-042 TCP048-060 WCP048-060 YCP048-060TCY036-042G WCY036-042G YCX036H-042 TCX048-060 WCX048-060G YCX048-060TCY048-060G WCZ036 YCY024-042 WCY048-060G YCY048-060

YCZ036F WCZ060F YCZ050, 060F

Page 349: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

AC/IN-9 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Table AC/IN-9-A Cooling/ Heat Pump Non-Bleed TXV Kits- Dual Direction FlowR-410 R-22 Used WithModel Number Model Numbers 13 SEER Coils4AYTXVH3D1831A 2AYTXVH3C1818A 2/4TXC,CXC,CXA -0184AYTXVH3D1831A 2AYTXVH3C2425A 2/4TXC,CXC,CXA -0244AYTXVH3D1831A 2AYTXVH3C2425A 2/4TXC,CXC,CXA -0254AYTXVH3D1831A 2AYTXVH3C3031A 2/4TXC,CXC,CXA -0304AYTXVH3D1831A 2AYTXVH3C3031A 2/4TXC,CXC,CXA -0314AYTXVH3D3343A 2AYTXVH3C3337A 2/4TXC,CXC,CXA -0364AYTXVH3D3343A 2AYTXVH3C3337A 2/4TXC,CXC,CXA -0374AYTXVH3D3343A 2AYTXVH3C4243A 2/4TXC,CXC,CXA -0424AYTXVH3D3343A 2AYTXVH3C4243A 2/4TXC,CXC,CXA -0434AYTXVH3D4863A 2AYTXVH3C4850A 2/4TXC,CXC,CXA -0484AYTXVH3D4863A 2AYTXVH3C4850A 2/4TXC,CXC,CXA -0494AYTXVH3D4863A 2AYTXVH3C4850A 2/4TXC,CXC,CXA -0504AYTXVH3D4863A 2AYTXVH3C5463A 2/4TXC,CXC,CXA -0604AYTXVH3D4863A 2AYTXVH3C5463A 2/4TXC,CXC,CXA -061

Table AC/IN-9-B Cooling/ Heat Pump Non-Bleed TXV Kits- Dual Direction FlowR-410 R-22 Used WithModel Number Model Number Horizontal Flat Coils4AYTXVH3D1831A 2AYTXVH3C1818A 2/4TXF -0184AYTXVH3D3343A 2AYTXVH3C3337A 2/4TXF -0334AYTXVH3D3343A 2AYTXVH3C4243A 2/4TXF -0414AYTXVH3D4863A 2AYTXVH3C5463A 2/4TXF -0544AYTXVH3D4863A 2AYTXVH3C5463A 2/4TXF -063

Table AC/IN-9-C Cooling/ Heat Pump Non-Bleed TXV Kits- Dual Direction FlowR-410 R-22 Used WithModel Model High EfficiencyNumber Number Aluminum Coils4AYTXVH3B2531A 2AYTXVH3B2531A 2/4TXC -0254AYTXVH3B2531A 2AYTXVH3B2531A 2/4TXC -0314AYTXVH3B3654A 2AYTXVH3B3637A 2/4TXC -0364AYTXVH3B3654A 2AYTXVH3B3637A 2/4TXC -0374AYTXVH3B3654A 2AYTXVH3B5454A 2/4TXC -0544AYTXVH3B6165A 2AYTXVH3B6161A 2/4TXC -0614AYTXVH3B6165A 2AYTXVH3B6565A 2/4TXC -065

Table AC/IN-9-D Cooling/ Heat Pump Non-Bleed TXV Kits- Dual Direction FlowR-410 R-22 Used WithNumber Numbers Air Handlers4AYTXVH3D1831A 2AYTXVH3D1830A 2TFB -018-0304AYTXVH3D1831A 2AYTXVH3D1830A 2/4TFE -025

4AYTXVH3D1831A 2AYTXVH3D1830A 2/4TEC -018-030 — 2AYTXVH3D3636A 2/4TEC -036

4AYTXVH3D3642A — 2/4TEC -036-042 — 2AYTXVH3D4260A 2/4TEC -042-060

4AYTXVH3D4863A — 2/4TEC -048-060

4AYTXVH3D1831A 2AYTXVH3D1830A 2TEH -018-030— 2AYTXVH3D3636A 2TEH -036

4AYTXVH3D3642A — 2TEH -036-042 — 2AYTXVH3D4260A 2TEH -042-060

4AYTXVH3D4863A — 2TEH -048-060

4AYTXVH3D1831A 2AYTXVH3D1830A 2TGB -018-0364AYTXVH3D3642A — 2TGB -042

— 2AYTXVH3D4260A 2TGB -042-0484AYTXVH3D4863A — 2TGB -048

Thermal Expansion Valves

Expansion Valve TXVCooling/Heat Pump Kit

General InformationThis Thermostatic Expansion Valve Kit maybe used on any indoor air handler or coil thatis equipped with a current thermostaticexpansion valve with an internal check valveand mechanical fittings This kit can be usedon split system heat pumps and air condi-tioning systems.

Thermostatic Expansion Valve Kits can befield installed to fit a variety of sizes andcombinations of air handlers or coils andoutdoor units to optimize performance.

This TXV kit will normally be used when adifferent refrigerant is going to be used in theair handler or coil than what is indicated onthe unit name plate. The TXV type must al-ways match the refrigerant type used in theoutdoor unit.

Kit IdentificationThe first character in the kit model numberindicates the type of refrigerant that thevalve can be used with. Example a2AYTXVH3D1830A is an R-22 valve.

The “3” in the eighth digit in the modelnumber identifies the valve as a non-bleedTXV. When this TXV kit is installed with anoutdoor unit that contains a reciprocatingcompressor, the outdoor unit must beequipped with a hard start kit if not factoryinstalled. If the outdoor unit contains a scrollcompressor, the installation of a hard startkit may be required.

InspectionCheck carefully for any shipping damage.Any such damage must be reported andclaims made against the transpor tationcompany immediately. Any missing partsshould be reported to your supplier at onceand replaced with authorized parts only.

Page 350: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

AC/IN-10Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

PHASED OUT

PHASED OUT

PHASED OUT

Thermal Expansion Valves

Expansion Valve TXVCooling Kit

Expansion Valve TXVHeat Pump Kit*

PHASED OUT

Table AC/IN-10-A — Cooling Bleed TXV Kits – Single Direction FlowLiquid Line Gas Line

Model Used With Connection Connection ShippingNumber AC Units Dia. I.D. (In.) Dia. I.D. (In.) Weight (Ibs.) Refrigerant

TAYTXVA0B5C 1-11/2 Ton 1/4 5/8 2 R-22TAYTXVA0C5C 2-21/2 Ton 5/16 3/4 2 R-22TAYTXVA0E5C 3-31/2 Ton 3/8 7/8 2 R-22TAYTXVA0G5C 4 Ton 3/8 11/8 2 R-22TAYTXVA0H5C 5-6 Ton 3/8 11/8 2 R-22

Table AC/IN-10-B — Cooling Non-Bleed TXV Kits – Single Direction FlowLiquid Line Gas Line

Model Used With Connection Connection ShippingNumber AC Units Dia. I.D. (In.) Dia. I.D. (In.) Weight (Ibs.) Refrigerant

TAYTXVA0B3C 1-11/2 Ton 1/4 5/8 2 R-22TAYTXVA0C3C 2-21/2 Ton 5/16 3/4 2 R-22TAYTXVA0E3C 3-31/2 Ton 3/8 7/8 2 R-22TAYTXVA0G3C 4 Ton 3/8 11/8 2 R-22TAYTXVA0H3C 5-6 Ton 3/8 11/8 2 R-22

Table AC/IN-10-C — Heat Pump Non- Bleed TXV Kits (also for cooling) – Dual Direction FlowLiquid Line Gas Line

Model Used With Connection Connection ShippingNumber AC Units Dia. I.D. (In.) Dia. I.D. (In.) Weight (Ibs.) Refrigerant

TAYTXVH0B3C 1-11/2 Ton 1/4 5/8 3 R-22TAYTXVH0C3C 2-21/2 Ton 5/16 3/4 3 R-22TAYTXVH0E3C 3-31/2 Ton 3/8 7/8 3 R-22TAYTXVH0G3C 4 Ton 3/8 11/8 3 R-22TAYTXVH0H3C 5-6 Ton 3/8 11/8 3 R-22

Table AC/IN-10-D— Cooling/Heat Pump Non-Bleed TXV Kits - Dual Direction Flow*Liquid Line Gas Line

Model Used With Connection Connection ShippingNumber AC Units Dia. I.D. (In.) Dia. I.D. (In.) Weight (Ibs.) Refrigerant

TAYTXVH0D3C 21/2 -3 Ton 3/8 11/8 2 R-22TAYTXVH0G3C 4 -5 Ton 3/8 11/8 2 R-22

* Used with TXH coils only where approved for use with 2 compressor systems.

Page 351: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

AC/IN-11 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Refrigerant Line Sets

Table AC/IN-11-A — Refrigerant Line SetsModel Gas Line23 Liquid Line Tonnages/W Tonnages/W ShippingNumber Dia. O.D. Dia. O.D. Length R-22 R-410A Weight

TAYREFLN125 5/8 1/4 25 1 & 11/2 13TAYREFLN130 5/8 1/4 30 1 & 11/2 15TAYREFLN140 5/8 1/4 40 1 & 11/2 20TAYREFLN150 5/8 1/4 50 1 & 11/2 28TAYREFLN225 3/4 5/16 25 2 & 21/2 21/2 15TAYREFLN230 3/4 5/16 30 2 & 21/2 21/2 18TAYREFLN240 3/4 5/16 40 2 & 21/2 21/2 23TAYREFLN250 3/4 5/16 50 2 & 21/2 21/2 32TAYREFLN325 7/8 3/8 25 3 & 31/2 4 & 5 20TAYREFLN330 7/8 3/8 30 3 & 31/2 4 & 5 24TAYREFLN340 7/8 3/8 40 3 & 31/2 4 & 5 30TAYREFLN350 7/8 3/8 50 3 & 31/2 4 & 5 39TAYREFLN425 11/81 3/8 25 4, 5, & 6 20TAYREFLN430 11/81 3/8 30 4, 5, & 6 24TAYREFLN440 11/81 3/8 40 4, 5, & 6 30TAYREFLN450 11/81 3/8 50 4, 5, & 6 39TAYREFLN550 1/2 1/4 50 1 & 11/2 26TAYREFLN625 5/8 5/16 25 2 15TAYREFLN630 5/8 5/16 30 2 17TAYREFLN640 5/8 5/16 40 2 22TAYREFLN650 5/8 5/16 50 2 29TAYREFLN725 3/4 3/8 25 3 & 31/2 19TAYREFLN730 3/4 3/8 30 3 & 31/2 22TAYREFLN740 3/4 3/8 40 3 & 31/2 28TAYREFLN750 3/4 3/8 50 3 & 31/2 351 Gas line is 7/8 O.D. but expanded out to 1-1/8 on the ends.2 Gas line 90o bend one end.3 Gas line insulation 1/2" thickness.Note: Contains a holding charge of Nitrogen.

Page 352: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

AC/IN-12Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Base Pan Sizes

Table AC/IN-12-A — Base Pan 450 X 37 X 34 46 X 37 X 34 42 X 37 X 34

Cooling Models Heat Pump Models Cooling Models Heat Pump Models Cooling Models Heat Pump Models

2TTX4048B 2TWX4042B 2TTX4042B 2TWX4036B 4TTX6036B 2TWX4030B2TTX4060B 2TWX4048B 2TTX5024B 2TWX5030A 2TWX5024A2TTX5036B 2TWX4060B 2TTX5030B 4TWX4036B2TTX5042B 2TWX5036A 4TTX4042B 4TWX6036B2TTX5048B 2TWX5042A2TTZ9030B 2TWX5048A2TTZ9036B 2TWZ9030B2TTZ9048B 2TWZ9036B2TTZ9060B 2TWZ9048B4TTX4048B 2TWZ9060B4TTX4060B 4TWX4042B4TTX6048B 4TWX4048B4TTX6060B 4TWX4060B

4TWX6048B4TWX6060B

Table AC/IN-12-B — Base Pan 348 X 33 X 30 44 X 33 X 30 40 X 33 X 30

Cooling Models Heat Pump Models Cooling Models Heat Pump Models Cooling Models Heat Pump Models

4TWX4024B 4TTX4036B 2TWX4024B 2TTX4018B 2TWX4018B4TWX4030B 4TTX6024B 4TWX6024B 2TTX4024B 4TWX4018B

2TTX4030B2TTX4036B4TTX4018B4TTX4024B4TTX4030B

Table AC/IN-12-C — Base Pan 441 X 37 X 34 37 x 37 x 34 33 X 37 X 34

Cooling Models Heat Pump Models Cooling Models Heat Pump Models Cooling Models Heat Pump Models

2TTR2060B 2TWR2060A 2TTR4042A 2TWR3036A 2TTR3042A 2TWR1060A2TTR3048A 2TWR3042A 4TTR4042A 2TWR4036A 4TTR2060A 2TWR4030A2TTR3060A 2TWR3048A 4TWR4036A 4TWR2048A2TTR4048A 2TWR3060A2TTR4060A 2TWR4042A4TTR4048A 2TWR4048A4TTR4060A 2TWR4060A

4TWR2060A4TWR4042A4TWR4048A4TWR4060A

Page 353: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

AC/IN-13 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Base Pan Sizes

Table AC/IN-13-A — Base Pan 341 X 33 X 30 37 X 33 X 30 33 X 33 X 30

Cooling Models Heat Pump Models Cooling Models Heat Pump Models Cooling Models Heat Pump Models

4TTR2048A 4TWR2042A 2TTR1060A 2TWR2048A 2TTR2042B 2TWR1042A4TWR4024A 2TTR2048A 2TWR3030A 2TTR3030A 2TWR1048A4TWR4030A 2TTR4030A 4TWR4024A 2TTR3036A 2TWR2036A

2TTR4036A 4TWR4018A 2TTR4018A 2TWR2042A4TTR2042A 2TTR4024A 2TWR4018A4TTR4036A 4TTR2018A 4TWR2018A

4TTR2024A 4TWR2024A4TTR2030A 4TWR2030A4TTR2036A 4TWR2036A4TTR4018A4TTR4024A4TTR4030A

Table AC/IN-13-B — Base Pan 233 X 29 X 26 29 X 29 X 26 26 X 29 X 26

Cooling Models Heat Pump Models Cooling Models Heat Pump Models Cooling Models Heat Pump Models

2TTR2036A 2TWR3018A 2TTR1042A 2TWR1030A 2TTR1030A 2TWR1018A2TTR3024A 2TWR3024A 2TTR1048A 2TWR1036A 2TTR1036A 2TWR1024A

2TTR2024A 2TWR2018A 2TTR2018A2TTR2030A 2TWR2024A 2TTR3018A

2TWR2030B

Table AC/IN-13-C — Base Pan 126 X 20 X 19

Cooling Models Heat Pump Models

2TTR1018A2TTR1024A

Page 354: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

AC/IN-14Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Base Pan Sizes

Table AC/IN-14-B — Base Pan 337 X 33 X 30 33 X 33 X 30

Cooling Models Heat Pump Models Cooling Models Heat Pump Models

2TTA2048A 2TWA2048A 2TTA0060A 2TWA0042A2TTA2060A 2TWA3030A 2TTA2042A 2TWA0048A2TTB2048A 2TWB2048A 2TTA3030A 2TWA2036A2TTB2060A 2TWB3030A 2TTA3036A 2TWA2042A

2TTB0060A 2TWB0042A2TTB2042A 2TWB0048A2TTB3030A 2TWB2036A2TTB3036A 2TWB2042A

Table AC/IN-14-A — Base Pan 441 X 37 X 34 37 X 37 X 34 33 X 37 X 34

Cooling Models Heat Pump Models Cooling Models Heat Pump Models Cooling Models Heat Pump Models

2TTA0072A 2TWA0072A 2TWA3036A 2TTA3042A 2TWA0060A2TTA3048A 2TWA2060A 2TWB3036A 2TTB3042A 2TWB0060A2TTA3060A 2TWA3042A2TTB3048A 2TWA3048A2TTB3060A 2TWA3060A

2TWB2060A2TWB3042A2TWB3048A2TWB3060A

Table AC/IN-14-C — Base Pan 233 X 29 X 26 29 X 29 X 26 26 X 29 X 26

Cooling Models Heat Pump Models Cooling Models Heat Pump Models Cooling Models Heat Pump Models

2TTA2036A 2TWB3018A 2TTA0042A 2TWA0030A 2TTA0030A 2TWB0012A2TTB2036A 2TWB3024A 2TTA0048A 2TWA0036A 2TTA0036A 2TWB0018A2TTB3024A 2TTA2030A 2TWA2030A 2TTB0030A 2TWB0024A

2TTB2024A 2TWB0030A 2TTB0036A 2TWB2018A2TTB2030A 2TWB0036A 2TTB0042A

2TWB2024A 2TTB0048A2TWB2030A 2TTB2018A

2TTB3018A

Page 355: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

AC/IN-15 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Equipment DateIdentification

YEAR DESIGNATIONS FROM 1980Residential, ID & OD1 Ducane Oil1 Residential, ID &OD1 DucaneOil1

Light Commercial Horizontal Light Commercial HorizontalYear Products & Compressors Gas Furnaces2 Year Products & Compressors Gas Furnaces2

1980 O,A L 1995 K 95

1981 T M 1996 L 96

1982 U N 1997 M 97

1983 W P 1998 N 98

1984 X Q 1999 P 99

1985 Y 85 2000 R —

1986 S 86 2001 Z —

1987 B 87 2002 2 —

1988 C 88 2003 3 —

1989 D 89 2004 4 —

1990 E 90 2005 5 —

1991 F 91 2006 6 —

1992 G 92 2007 7 —

1993 H 93 2008 8 —

1994 J 94 2009 9 —

The nine digit serial numbers on all Trane central air conditioning and heatingproducts are employed to identify the year and fiscal week of product manufacture.

Year of manufacture .......................... First digit ................................... M124X04CF

Fiscal week of manufacture ............... Second and third digit ............... M124X04CF

Day of week of manufacture .............. Fourth digit ............................... M124X04CF

Consecutive order of production ........ Last Five digits ......................... M124X04CF

Exception – Accessories are an exception to the nine digit serial numberassignment and may have only three digits to indicate date code.Coils which have only three digits to indicate date code are an exceptionto the nine digit serial number assignment.

1 Beginning with 1/1/96 (L01) Ducane oil furnace production uses same datecode method as gas furnace. Prior to 1/1/96 Ducane serial number usedlast four digits = date code, example HA1234569540 1995, 40th week.

2 Dedicated horizontal gas furnaces, production ceased after introduction ofconvertible furnaces.

Example: 123456-8 5 4 0

Year of manufacture Fiscal week of manufacture

Page 356: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

AC/IN-16Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Refrigerant HCFC 22 (R-22)

Table AC/IN-16-A — Allowable Suction Line Diameters and Capacities (R-22)

Table AC/IN-16-B — Liquid Line Selection Table for R-22 Systems

Note 1: * indicates values more than 10% capacity loss.Note 2: --- indicates values more than 15% capacity loss.

Refrigerant Line Limits1. Do not use traps.2. The suction line diameter must be one of the sizes listed.3. Use the recommended liquid line size unless the total pressure drop (friction loss

plus liquid lift) exceeds: 35 PSI.4. Refer to 7½ - 20 ton section to determine appropriate refrigerant line size for 7½, 10,

12½, 15 and 20 ton split systems.5. XL19i - Max length = 80 – of that max length, 25 feet may be vertical.

This page contains limited data for an unskilled user to fully determine if the application will work or toselect required accessories. Please refer to publication #22-3317-01 for complete details and examples.

Tables contain no allowances for vertical lift!

Page 357: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

AC/IN-17 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Refrigerant HFC 410A (R-410A)

Table AC/IN-17-A

Allowable Liquid Line Diameters and Pressure Drops

Allowable Suction Line Diameters and Capacity Losses

Table AC/IN-17-B

Note 1: A blank space indicates a pressure drop of over than 50 PSI.Note 2: Other existing sources of pressure drop such as (solenoid valves, etc.) must be considered.Note 3: A vertical run with a heat pump system always results in a liquid lift (heating or cooling).Note 4: The smallest liquid line diameter that results in a total liquid line pressure drop of 50 PSI or less results in the most reliable system (fewer pounds of R-410A).

Note * Rated tube size.Note 1: Shaded value indicates more than 10% capacity loss.Note 2: Blank space indicates more than 15% capacity loss.

Tables contain no allowances for vertical lift!

Refrigerant Line Limits1. Do not use traps.2. The suction line diameter must be one of the sizes listed. Use the actual tonnage of

the system in selecting line sizes.3. Use the recommended liquid line size unless the total pressure drop (friction loss

plus liquid lift) exceeds: 50 PSI.4. XL16i - Max length = 80 – of that max length, 25 feet may be vertical.

This page contains limited data for an unskilleduser to fully determine if the application will workor to select required accessories. Please refer topublication #22-3317-01 for complete details andexamples.

Page 358: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

AC/IN-18Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Page 359: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

AC/IN-19 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Page 360: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

AC/IN-20Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

���������������������������� ��� ��� ������������������������ ��������������� �������������������������������������������� ���������������������� ��� ��� ���������������� ������������� �������������� ���������������������������������������� ��������� ��������

������������������������ ������ ��� ��������������������� ����� ����������������!����������������� ����� ��� ��"����������� ��������������� �������!���� �����������!������������ ������� ���������������������� �������������� ��������������������� ���������������������#������������������������������ �����$%�����&'�%��(�������)��$%������&*+�������%��������������������� ���

7 1/2 - 20 Ton (HCFC-22)Split System Refrigerant Piping

TTA Liquid Suction Applicable line length and rise:: x=total line length (hor+vert) : y=total line rise 090a 1/2 1- 3/8120a 1/2 1- 3/8 For 0<=x<=50: x=y120b 3/8 1- 1/8 For 50<x<=150: y=62.5-.25x120c 1/2 1- 3/8150b 1/2 1- 3/8180b 1/2 1- 3/8180c 5/8 1- 5/8240b 1/2 1- 3/8

TWA Liquid Suction Applicable line length and rise:: x=total line length (hor+vert) : y=total line rise 090a 1/2 1- 3/8120a 1/2 1- 3/8 for 0<=x<=50: x=y180b 1/2 1- 3/8 For 50<x<=150: y=62.5-.25x240b 1/2 1- 3/8 Same as TTA

50

50 150

25

Total Length

Acceptable

Call Trane for reviewTotal Rise

Page 361: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

AC/IN-21 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175

10

15

20

25

30

35

40

45

50

55

60

65

70

75

80

85

90

95

100

105

110

115

120

125

13050 100 150 200 250 300 350

BRANCH CIRCUIT WIRE SIZING TABLE(Based on 2% Voltage Drop)

Chart is based on 75˚ C. wire. (Types FEPW, RH, RHW,THHW,THW,THWN, XHHW, USE, AND ZW.)

Use Chart For Wire Sizing Only. Refer To Electrical Code, (Or Product Specs.) For Fuse Sizing

Suitable for 1 Ph. or 3 Ph. Circuits 75˚ C. Insulation; 30˚ C. Ambient Temp. (80˚ F.)DISTANCE (POWER SUPPLY TO LOAD) IN FEET (208-230V) Not more than three conductors per raceway

RE

QU

IRE

D B

RA

NC

H C

IRC

UIT

AM

PAC

ITY

Distance (power supply to load in feet (460V).See National Electrical Code for Temperature corrections and other variables. All wiring must comply with Local Codes

#12 Copperor

#10 Aluminum

#10 Copperor

#8 Aluminum

#8 Copperor

#6 Aluminum

#6 Copperor

#4 Aluminum

#4 Copperor

#2 Aluminum

#2 Copperor

#0 Aluminum

Branch Circuit Wire Sizing Table/Heater De-Rating Chart

The output of electric heaters, applied at voltages other than the rated 240 or 480 volts, can beeasily determined with the use of this chart.

Heater De-Rating Chart

Page 362: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

AC/IN-22Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Basic Air Conditioning Formulas

ApplicationGuide

Basic Air Conditioning FormulasCOOLINGTO DETERMINE

Total Airflow

Infiltration or Ventilation

Number of Air Changes Per Hour – Total

Number of Air Changes Per Hour – Outdoor Air

Total Heat (HT)

Sensible Heat (HS)

Latent Heat (HL)

Leaving Air D.B.Temperature (T2)

Enthalpy – Leaving Air (h2)

Leaving Air W.B. Temperature

Heat Required to EvaporateWater Vapor Added toVentilation Air

Humidification Requirements

CFMTCFMoNTNoVHTHSHLh1h2T1T2Tadpt1t2W1W2W3Wo

**

Btu/lb.Btu/lb.

°F.D.B.°F.D.B.°F.D.B.Grains/lb.Grains/lb.Grains/lb.Grains/lb.

===================

Total airflow cubic feet/min.Outdoor air cubic feet/min.Total air changes per hourOutdoor air, air changes per hourVolume of space cubic feetTotal heat BtuhSensible heat BtuhLatent heat BtuhEnthalpy or total heat of entering air Enthalpy or total heat of leaving airTemperature of entering airTemperature of leaving airApparatus dewpointIndoor design temperatureOutdoor design temperatureGrains of water/lb. of dry air at entering conditionGrains of water/lb. of dry air at leaving conditionGrains of water/lb. of dry air at indoor design conditionsGrains of water/lb. of dry air at outdoor design conditions

The air constants below apply specifically to standard air which is defined as dry air at 70°F and 14.7 P.S.I.A. (29.92 in. mercury column).They can, however, be used in most cooling calculations unless extremelyprecise results are desired.

4.5 (To convert CFM to lbs./hr.)

Where 13.33 is the specific volume of standard air (cu.ft./lb.) and .075 is the density (lbs./cu.ft.)

4.5 = 60 min./hr.13.33

or 60 X .075

Required Airflow

Entering Air Temperature (T1) (Mixed Air)

CFMT =NT V

60 min./hr.

HT = CFMT x 4.5 x (h1 – h2) = Btuh

HS = CFMT x 1.08 x (T1 – T2) = Btuh

HL = CFMT x .68 x (W1 – W2) = Btuh

T2 = T1 – = °F.D.B.

Refer to Enthalpy Table and read W.B. temperaturecorresponding to enthalpy of leaving air (h2) (see #17).

Refer to Enthalpy Table and read W.B. temperaturecorresponding to enthalpy of leaving air (h2) (see #18).

HL = CFMo x .68 (W3 – Wo) = Btuh

= = lbs./hr.

(Industrial Process Work)

HL = CFMo x .68 (W3 – Wo) = Btuh

Make upMoisture( )

T1 = t1 +

1 If duct heat gain is a factor, add to T1:

x (t2 – t1) = °F.D.B. 1

HT = CFMT x 4.5 x (h2 – h1) = Btuh

HS = CFMT x 1.08 x (T2 – T1) = Btuh

HL = CFMT x .68 x (W2 – W1) = Btuh

CFMT

CFMo

NT

No

Btuh

Btuh

Btuh

°F. D.B.

Btu/lb.dry air

°F.W.B.

Btuh

Lbs.water/hr.

CFMT

°F. D.B.

1.

2.

3.

4.

6.

8.

10.

14.

18.

20.

22.

24.

16.

12.

1.

2.

3.

4.

5.

7.

9.

13.

17.

19.

21.

23.

15.

11.

LEGEND DERIVATION OF AIR CONSTANTS

HEATING and/or HUMIDIFYINGEXPRESSED

AS

CFMT =NT V

60 min./hr.

CFMo =NO V

60 min./hr.

NT =CFMT (60 min./hr.)

VNT =

CFMT (60 min./hr.)

V

No =CFMo (60 min./hr.)

V

HSCFMT x 1.08

h2 = h1 – = Btu/lb. dry airHT

CFMT x 4.5

Excess Latent Capacityof System x % Run Time

1060 Btu/lb.= = lbs./hr.Make up

Moisture( ) HL loss Btuh (see #22)

1060 Btu/lb.

h2 = h1 + = Btu/lb. dry airHT

CFMT x 4.5

CFMT =

OR

= CFMHS (total)

1.08 x (T1 – T2)CFMT = = CFM

HS1.08 x (T2 – T1)

CFMT =

3 Sensible load of outside air not included

= CFMHS (internal)3

1.08 x (t1 – T2)

T2 = T1 + = °F.D.B.HS

CFMT x 1.08

Duct Heat Gain (Btuh)CFMT x 1.08

CFMoCFMT

T1 = t1 –

2 If duct heat loss is a factor, subtract from T1:

x (t1 – t2) = °F.D.B. 2

Duct Heat Loss (Btuh)CFMT x 1.08

CFMoCFMT

No =CFMo (60 min./hr.)

V

CFMo =No V

60 min./hr.

1.08 = .24 X 6013.33

or .24 X 4.5

.24 BTU = specific heat of standard air (BTU/LB/°F)

Where: 1060 = Average Latent Heat of water vapor (BTU/LB.).

7000 = Grains per lb.

.68 = 6013.33

or 4.5 XX 10607000

10607000

* See Enthalpy of air (Total Heat Content of Air) Table for exact values.

Page 363: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

AC/IN-23 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Notes:1 Scroll compressors unload during the off cycle and do not require hard start components due to refrigerant pressure differential. However, it is

recommended to install start kit when operating below 30°F.2 For all systems employing head pressure control, a non-bleed thermal expansion valve (NB-TXV) is required. TWE060A has a factory installed bleed

port TXV. If belt drive is preferred (TWE060A), it is recommended to change the TXV to a non-bleed type.3 If off cycle time exceeds 30 minutes at low outdoor ambient conditions, it is recommended to install a liquid line solenoid valve.

a) If solenoid valve is required, pressure drop across the solenoid valve plus liquid line pressure drop shall be no greater than 35 PSI for R-22 systemsand 50 PSI for R410A systems.

4 Wind shields may be required, please refer to the following pages to locate documentation regarding windshields.5 System indoor airflow shall be no less than 370 CFM / Ton when applying head pressure control.6 Check Product Data General Specification page in order to determine if the condensing unit ships with required components such as crankcase heat or

start components.7 If non bleed thermal expansion valve is used in a system bearing a reciprocating style compressor, the condensing unit must have quick start compo-

nents. Check Product Data for factory-installed components in order to determine if a quick start accessory is required.8 BAYLOAM104 includes integrated quick start kit.* Please refer to Product Data.** BAYCCHT (Crankcase Heater) is factory installed.

Low Ambient AccessoriesCooling Models

ModelFamily 55oF 45oF 30oF OoF

For a detailed Application Bulletin on required accessories and wind shields for lowoutdoor ambient operation, please contact your Territory Manager or Local FSR.

XL19iAsShipped

AsShipped

AY28X079 TXV-NB7 BAYCCHT* Not Approved

XL16iAsShipped

AsShipped

AY28X079 TXV-NB7 BAYCCHT* Not Approved

XL15iAsShipped

AsShipped

AY28X079 TXV-NB7 BAYCCHT* Not Approved

XL14iR-22 / R-410A

AsShipped

TXV7 AY28X079 TXV-NB7 BAYCCHT* Not Approved

XR14R-22 / R-410A

AsShipped

TXV7 AY28X079 TXV-NB7 BAYCCHT* Not Approved

XR13AsShipped

TXV7 AY28X079 TXV-NB7 BAYCCHT* BAYLOAM103 TXV-NB7 BAYCCHT*Quick StartKit

SolenoidValve3

XR12 - R-410AAsShipped

TXV7 AY28X079 TXV-NB7 BAYCCHT* Not Approved

XR12 - R-22AsShipped

TXV7 AY28X079 TXV-NB7 BAYCCHT* BAYLOAM103 TXV-NB7 BAYCCHT*Quick StartKit

SolenoidValve3

2TTA3 /2TTA2 / 2TTA0

Asshipped

TXV7 AY28X079 TXV-NB7 ** BAYLOAM103 TXV-NB7 ** 3 phasenot needed

SolenoidValve3

2.5 to 5 TonXR11

AsShipped

TXV7 AY28X079 TXV-NB7 BAYCCHT* BAYLOAM103 TXV-NB7 BAYCCHT*Quick StartKit

SolenoidValve3

1.5 to 2 TonXR11

AsShipped

TXV7 AY28X079 TXV-NB7 BAYCCHT* BAYLOAM104 TXV-NB7 BAYCCHT*Quick StartKit8

SolenoidValve3

XB13AsShipped

TXV7 AY28X079 TXV-NB7 BAYCCHT* BAYLOAM103 TXV-NB7 BAYCCHT*Quick StartKit

SolenoidValve3

XB12Asshipped

TXV7 AY28X079 TXV-NB7 BAYCCHT* BAYLOAM103 TXV-NB7 BAYCCHT*Quick StartKit

SolenoidValve3

2.5 to 5 TonXB10

AsShipped

TXV7 AY28X079 TXV-NB7 BAYCCHT* BAYLOAM103 TXV-NB7 BAYCCHT*Quick StartKit

SolenoidValve3

TTB012 thru 024 AsShipped

TXV7 AY28X079 TXV-NB7 BAYCCHT* BAYLOAM104 TXV-NB7 BAYCCHT*Quick StartKit8

SolenoidValve3

Page 364: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

AC/IN-24Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Notes:1 Scroll compressors unload during the off cycle and do not require hard start components due to refrigerant pressure differential. However, it is

recommended to install a start kit when operating below 30°F.2 For all systems employing head pressure control, a non-bleed thermal expansion valve (NB-TXV) is required. All heat pump expansion valve accesso-

ries are non-bleed type. TWE060A has a factory installed bleed port TXV. If belt drive is preferred (TWE060A), it is recommended to change the TXV toa non-bleed type.

3 Wind shields may be required, please refer to the following pages to locate documentation regarding windshields.4 System indoor airflow shall be no less than 370 CFM / Ton.5 Do not use solenoid valves with heat pump systems.6 Check Product Data General Specification page in order to determine if the heat pump unit ships with required components such as crankcase heat or

start components.7 If non bleed thermal expansion valve is used in a system bearing a reciprocating style compressor, the condensing unit must have quick start compo-

nents. Check Product Data for factory-installed components in order to determine if a quick start accessory is required.* Please refer to Product Data.** BAYCCHT (Crankcase Heater) is factory installed.

Low Ambient AccessoriesHeat Pump Models

ModelFamily 55oF 45oF 30oF34 OoF34

For a detailed Application Bulletin on required accessories and wind shields for lowoutdoor ambient operation, please contact your Territory Manager or Local FSR.

XL19iAsShipped

As Shipped AY28X084 TXV-NB7 BAYCCHT* Not Approved

XL16i AsShipped

As Shipped AY28X084 TXV-NB7 BAYCCHT* Not Approved

XL15iAsShipped As Shipped AY28X084 TXV-NB7 BAYCCHT* Not Approved

XL14iR-22 / R-410A

AsShipped

TXV-NB7 AY28X084 TXV-NB7 BAYCCHT* Not Approved

XR14R-22 / R-410A

AsShipped

TXV-NB7 AY28X084 TXV-NB7 BAYCCHT* Not Approved

XR13AsShipped

TXV-NB7 AY28X084 TXV-NB7 BAYCCHT* BAYLOAM103 TXV-NB7 BAYCCHT6Quick StartKit6

XR12 - R410AAsShipped

TXV-NB7 AY28X084 TXV-NB7 BAYCCHT* Not Approved

XR12 - R-22 AsShipped

TXV-NB7 AY28X084 TXV-NB7 BAYCCHT* BAYLOAM103 TXV-NB7 BAYCCHT6Quick StartKit6

XR11AsShipped TXV-NB7

QuickStartKit

AY28X084 TXV-NB7

QuickStartKit

BAYCCHT* BAYLOAM103 TXV-NB7 BAYCCHT6Quick StartKit6

XB13AsShipped

TXV-NB7 AY28X084 TXV-NB7 BAYCCHT* BAYLOAM103 TXV-NB7 BAYCCHT6Quick StartKit6

XB12AsShipped

TXV-NB7

QuickStartKit

AY28X084 TXV-NB7

QuickStartKit

BAYCCHT* BAYLOAM103 TXV-NB7 BAYCCHT6Quick StartKit6

XB10AsShipped

TXV-NB7

QuickStartKit

AY28X084 TXV-NB7

QuickStartKit

BAYCCHT* BAYLOAM103 TXV-NB7 BAYCCHT6Quick StartKit6

2TWA3 /2TWA2 / 2TWA0

AsShipped

TXV-NB73phase

AY28X084 TXV-NB73phase ** BAYLOAM103 TXV-NB7 ** 3 phase

Page 365: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

AC/IN-25 Effective 1/1/06For complete equipment / combinationselections and installation instructions, pleaserefer to Product Data and/or Installers Guides.

Wind Shields

Wind Shields are required to blockprevailing winds across condensercoil. In applications where cooling

operation is required to 0°F, windshields are a Must. Use the followingguidelines for your application.

Notes:Minimum working clearance must be in compliance with the National Electric Code. Currently,the minimum clearance between a wood or suitable grounding material type fence requiresminimum 3 feet. If other material is used to form the windshield, the minimum space may beincreased to 3.5 feet. Please consult the 2002 Edition of the National Electric Code, Article 110for the most up to date information, please refer to the most current National Electric Code.

For a detailed Application Bulletin on required accessories and wind shieldsfor low ambient operation, please contact your Territory Manager or Local FSR.

Page 366: Trane Residential an.. - HVAC.Amickracing Residential and Light... · 2007-01-16Trane Residential an.. - HVAC.Amickracing

Literature Order Number

File No. Pub. No. 22-8301-15 1/06

Supersedes Pub. No. 22-8301-14 10/05(Electronic Only)

P.O. Box 9010Tyler TX 75711-9010http://www.trane.com

Stocking location PI (L)

Since Trane has a policy of continuous product improvement, it reserves the right to change design andspecifications without notice.© 2006 American Standard All rights reserved

A Business of American StandardCompanies.