trane product data upflow/horizontal right or upflow
TRANSCRIPT
Upflow/Horizontal Rightor Upflow/Horizontal LeftInduced Draft Gas Furnace
XR 80
PUB. NO. 22-1640-13
TUD1A040A9241A, TUD1A040A9301A, TUD1A060A9241A,TUD1A060A9361A, TUD1B060A9361A, TUD1B080A9241A,TUD1B080A9361A, TUD1B080A9481A, TUD1C080A9601A, TUD1B100A9361A, TUD1B100A9451A, TUD1C100A9481A,TUD1C100A9601A, TUD1D100A9721A, TUD1C120A9541A,TUD1D120A9601A, TUD1D140A9601A
Single-Stage Fan Assisted Combustion System
2 Pub. No. 22-1640-13
GeneralFeatures
© 2015 Trane All Rights Reserved
NATURAL GAS MODELSCentral Heating furnace designs are certified by the American and Cana-dian Gas Associations for both natural and L.P. gas. Limit setting and rating data were established and approved under standard rating conditions using American National Standards Institute standards.
SAFE OPERATIONThe Integrated System Control has solid state devices, which continuously monitor for presence of flame, when the system is in the heating mode of opera-tion. Dual solenoid combination gas valve and regulator provide extra safety.
QUICK HEATINGDurable, cycle tested, heavy gauge aluminized steel heat exchanger quickly transfers heat to provide warm conditioned air to the structure.
BURNERSMultiport Inshot burners will give years of quiet and efficient service. All models can be converted to L.P. gas.
INTEGRATED SYSTEM CONTROLExclusively designed operational pro-gram provides total control of furnace limit sensors, blowers, gas valve, flame control and includes self diagnostics for ease of service. Also contains connec-tion points for E.A.C./humidifier.
AIR DELIVERYThe 4-speed, direct drive blower motor, has sufficient airflow for most heating and cooling requirements, will switch from heating to cooling speeds on demand from room thermostat. The blower door safety switch will prevent or terminate furnace operation when the blower door is removed.
STYLINGHeavy gauge steel and “wrap-around” cabinet construction is used in the cabinet with baked-on enamel finish for strength and beauty. The heat exchang-er section of the cabinet is completely lined with foil faced fiberglass insulation. This results in quiet and efficient opera-tion due to the excellent acoustical and insulating qualities of fiberglass.
FEATURES AND GENERAL OPERATIONThe XR 80 High Efficiency Gas Fur-naces empoys an adaptive Hot Surface Ignition system, which eliminates the waste of a constant burning pilot. The integrated system control lights the main burners upon a demand for heat from the room thermostat. Complete front service access.
a. Low energy power venter b. Vent proving pressure switch.
3Pub. No. 22-1640-13
Contents
General Features 2Features and Benefits 4
Standard Equipment 4Optional Equipment 4
General Data 5TUD1A040A9241A 5TUD1A040A9301A 5TUD1A060A9241A 6TUD1A060A9361A 6TUD1B060A9361A 6TUD1B080A9241A 7TUD1B080A9361A 7TUD1B080A9481A 7TUD1C080A9601A 7TUD1B100A9361A 8TUD1B100A9451A 8TUD1C100A9481A 8TUD1C100A9601A 8TUD1D100A9721A 9TUD1C120A9541A 9TUD1D120A9601A 9TUD1D140A9601A 9
Performance Data 10Field Wiring 12Dimensions 14Electrical Data 15
4 Pub. No. 22-1640-13
Featuresand Benefits
XR 80 UPFLOW/HORIZONTAL RIGHT or LEFT
STANDARD EQUIPMENT
• Power supply 115/1/60
•Multi-port In-shot burners
• Integrated solid state control with self diagnostics
•Silicon Nitride hot surface igniter with adaptive heat up
•Complete front service access
•Heavy guage aluminized steel heat exchanger
•Slide out blower assembly
•Blower door safety switch
•Direct drive, 4-speed motor
•Optional L.P. conversion kit
•Common vent
•Alternate bottom/left/right return air
•Hinged blower door
•Perfect Fit door latches
•Gasketed blower door
•Single wire twinning
• Selectable cooling fan off delay
•Left-right gas connection
•Optional L.P. conversion kit
•Common vent capability
•24 volt fuse
•Manual reset flame roll out switches
•Insulated blower door
•Insulated blower compartment
•Accessoryhook-upcapability-Humand EAC
•Blowerdoorsafetyswitch
XR 80 OPTIONAL EQUIPMENT
Thermostat ...............................................................................................................................................................BAYSTAT388 [ ]Thermostat, Heating/Cooling Single Stage (Mounts Horizontally) .............................................................................. AY28X092 [ ]Thermostat, Heating/Cooling Single Stage (Mounts Vertically) ................................................................................BAYSTAT305 [ ]Thermostat, Electronic Programmable 1-Stage Heating/1-Stage Cooling ............................................................. TAYSTAT300C [ ]Propane Conversion Kit .........................................................................................................................................BAYLPKT210A [ ]Electronic Air Filter, “Perfect Fit” High Efficiency (14-1/2" Wide Gas Furnace) ......................................................TFM145A9FR1 [ ]Electronic Air Filter, “Perfect Fit” High Efficiency (17-1/2" Wide Gas Furnace) ......................................................TFM175A9FR1 [ ]Electronic Air Filter, “Perfect Fit” High Efficiency (21" Wide Gas Furnace) ............................................................TFM210A9FR1 [ ]Electronic Air Filter, “Perfect Fit” High Efficiency (24-1/2" Wide Gas Furnace) ......................................................TFM245A9FR1 [ ] Electronic Air Filter, “Perfect Fit” Standard Efficiency (17-1/2" Wide Gas Furnace)............................................. TFP175A9FR01 [ ]Electronic Air Filter, “Perfect Fit” Standard Efficiency (21" Wide Gas Furnace) ................................................... TFP210A9FR01 [ ]Electronic Air Filter, “Perfect Fit” Standard Efficiency (24-1/2" Wide Gas Furnace)............................................. TFP245A9FR01 [ ]Coil Enclosure (14-1/2" Wide Cabinets) ..........................................................................................................BAYCLE14A1422A [ ]Coil Enclosure (17-1/2" Wide Cabinets) ..........................................................................................................BAYCLE17A1722A [ ]Coil Enclosure (21" Wide Cabinets) ................................................................................................................BAYCLE21A2130A [ ]Coil Enclosure (24-1/2" Wide Cabinets) ..........................................................................................................BAYCLE24A2430A [ ]High Altitude Pressure Switch Kit .............................................................................................................................BAYHALT248 [ ]Masonry Chimney Vent Kit (Upflow models only) ................................................................................................. BAYVENT800B [ ]Filter Rack Kit ....................................................................................................................................................... BAYRACK960A [ ]
5Pub. No. 22-1640-13
MODELTYPE RATINGS 2 Input BTUH Capacity BTUH (ICS) 3 AFUE Temp. rise (Min.-Max.) °F. BLOWER DRIVE Diameter - Width (In.) No. Used Speeds (No.) CFM vs. in. w.g. Motor HP R.P.M. Volts / Ph / Hz COMBUSTION FAN - Type Drive - No. Speeds Motor HP - RPM Volts / Ph / Hz FLA FILTER — Furnished? Type Recommended Hi Vel. (No.-Size-Thk.) VENT — Size (in.) HEAT EXCHANGERType-Fired -Unfired Gauge (Fired) ORIFICES — MainNat. Gas. Qty. — Drill Size L.P. Gas Qty. — Drill Size GAS VALVE PILOT SAFETY DEVICE Type BURNERS — Type Number POWER CONN. — V / Ph / Hz 4 Ampacity (In Amps) Max Overcurrent Protection (Amps) PIPE CONN. SIZE (IN.) DIMENSIONS Crated (In.) WEIGHTShipping (Lbs.) / Net (Lbs)
GeneralData
1 Central Furnace heating designs are certified by AGA and CSA.2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian
applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
PRODUCT SPECIFICATIONS 1
TUD1A040A9241AUpflow / Horizontal
40,00032,00080.0
30 - 60DIRECT10 x 6
14
See Fan Performance Table1/5
1080115/1/60
CentrifugalDirect - 1
1/50 - 3000115/1/60
1.0No
High Velocity1 - 16x25 - 1in.
4 Round
Aluminized Steel - Type I
20
2 — 452 — 56
Redundant - Single Stage
Hot Surface IgnitionMultiport Inshot
2115/1/60
6.3151/2
H x W x D41-3/4 x 16-1/2 x 30-1/2
119 / 110
TUD1A060A9241AUpflow / Horizontal
60,00047,00080.0
35 - 65DIRECT10 x 6
14
See Fan Performance Table1/5
1080115/1/60
CentrifugalDirect - 1
1/50- 3000115/1/60
1.0No
High Velocity1 - 16x25 - 1in.
4 Round
Aluminized Steel - Type I
20
3 — 453 — 56
Redundant - Single Stage
Hot Surface IgnitionMultiport Inshot
3115/1/60
10.4151/2
H x W x D41-3/4 x 16-1/2 x 30-1/2
124 / 115
TUD1A040A9301AUpflow / Horizontal
40,00032,00080.0
30 - 60DIRECT10 x 6
14
See Fan Performance Table1/3
1075115/1/60
CentrifugalDirect - 1
1/50 - 3000115/1/60
1.0No
High Velocity1 - 16x25 - 1in.
4 Round
Aluminized Steel - Type I
20
2 — 452 — 56
Redundant - Single Stage
Hot Surface IgnitionMultiport Inshot
2115/1/60
6.3151/2
H x W x D41-3/4 x 16-1/2 x 30-1/2
122 / 113
6 Pub. No. 22-1640-13
TUD1B080A9241AUpflow / Horizontal
80,00064,00080.0
50 - 80DIRECT
9 x 714
See Fan Performance Table1/5
1080115/1/60
CentrifugalDirect - 1
1/50- 3000115/1/60
1.0No
High Velocity1 - 17x25 - 1in.
4 Round
Aluminized Steel - Type I
20
4 — 454 — 56
Redundant - Single Stage
Hot Surface IgnitionMultiport Inshot
4115/1/60
10.4151/2
H x W x D41-3/4 x 19-1/2 x 30-1/2
139 / 129
MODELTYPE RATINGS 2 Input BTUH Capacity BTUH (ICS) 3 AFUE Temp. rise (Min.-Max.) °F. BLOWER DRIVE Diameter - Width (In.) No. Used Speeds (No.) CFM vs. in. w.g. Motor HP R.P.M. Volts / Ph / Hz COMBUSTION FAN - Type Drive - No. Speeds Motor HP - RPM Volts / Ph / Hz FLA FILTER — Furnished? Type Recommended Hi Vel. (No.-Size-Thk.) VENT — Size (in.) HEAT EXCHANGERType-Fired -Unfired Gauge (Fired) ORIFICES — MainNat. Gas. Qty. — Drill Size L.P. Gas Qty. — Drill Size GAS VALVE PILOT SAFETY DEVICE Type BURNERS — Type Number POWER CONN. — V / Ph / Hz 4 Ampacity (In Amps) Max Overcurrent Protection (Amps) PIPE CONN. SIZE (IN.) DIMENSIONS Crated (In.) WEIGHTShipping (Lbs.) / Net (Lbs)
TUD1A060A9361AUpflow / Horizontal
60,00047,00080.0
30 - 60DIRECT10 x 6
14
See Fan Performance Table1/3
1075115/1/60
CentrifugalDirect - 1
1/50- 3000115/1/60
1.0No
High Velocity1 - 16x25 - 1in.
4 Round
Aluminized Steel - Type I
20
3 — 453 — 56
Redundant - Single Stage
Hot Surface IgnitionMultiport Inshot
3115/1/60
9.0151/2
H x W x D41-3/4 x 16-1/2 x 30-1/2
127 / 118
TUD1B060A9361AUpflow / Horizontal
60,00047,00080.0
30 - 60DIRECT10 x 7
14
See Fan Performance Table1/3
1075115/1/60
CentrifugalDirect - 1
1/50- 3000115/1/60
1.0No
High Velocity1 - 17x25 - 1in.
4 Round
Aluminized Steel - Type I
20
3 — 453 — 56
Redundant - Single Stage
Hot Surface IgnitionMultiport Inshot
3115/1/60
9.0151/2
H x W x D41-3/4 x 19-1/2 x 30-1/2
137 / 127
1 Central Furnace heating designs are certified by AGA and CSA.2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian
applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
PRODUCT SPECIFICATIONS 1
GeneralData
7Pub. No. 22-1640-13
GeneralData
1 Central Furnace heating designs are certified by AGA and CSA.2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian
applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
MODELTYPE RATINGS 2 Input BTUH Capacity BTUH (ICS) 3 AFUE Temp. rise (Min.-Max.) °F. BLOWER DRIVE Diameter - Width (In.) No. Used Speeds (No.) CFM vs. in. w.g. Motor HP R.P.M. Volts / Ph / Hz COMBUSTION FAN - Type Drive - No. Speeds Motor HP - RPM Volts / Ph / Hz FLA FILTER — Furnished? Type Recommended Hi Vel. (No.-Size-Thk.) VENT — Size (in.) HEAT EXCHANGERType-Fired -Unfired Gauge (Fired) ORIFICES — MainNat. Gas. Qty. — Drill Size L.P. Gas Qty. — Drill Size GAS VALVE PILOT SAFETY DEVICE Type BURNERS — Type Number POWER CONN. — V / Ph / Hz 4 Ampacity (In Amps) Max Overcurrent Protection (Amps) PIPE CONN. SIZE (IN.) DIMENSIONS Crated (In.) WEIGHTShipping (Lbs.) / Net (Lbs)
PRODUCT SPECIFICATIONS 1
TUD1B080A9361AUpflow / Horizontal
80,00063,00080.0
30 - 60DIRECT10 x 7
14
See Fan Performance Table1/3
1075115/1/60
CentrifugalDirect - 1
1/50- 3000115/1/60
1.0No
High Velocity1 - 17x25 - 1in.
4 Round
Aluminized Steel - Type I
20
4 — 454 — 56
Redundant - Single Stage
Hot Surface IgnitionMultiport Inshot
4115/1/60
10.4151/2
H x W x D41-3/4 x 19-1/2 x 30-1/2
142 / 132
TUD1B080A9481AUpflow / Horizontal
80,00064,00080.0
30 - 60DIRECT10 x 8
14
See Fan Performance Table1/3
1075115/1/60
CentrifugalDirect - 1
1/50- 3000115/1/60
1.0No
High Velocity1 - 17x25 - 1in.
4 Round
Aluminized Steel - Type I
20
4 — 454 — 56
Redundant - Single Stage
Hot Surface IgnitionMultiport Inshot
4115/1/60
9.1151/2
H x W x D41-3/4 x 19-1/2 x 30-1/2
142 / 132
TUD1C080A9601AUpflow / Horizontal
80,00064,00080.0
25 - 55DIRECT11 x10
14
See Fan Performance Table3/4
1100115/1/60
CentrifugalDirect - 1
1/50- 3000115/1/60
1.0No
High Velocity1 - 20x25 - 1in.
4 Round
Aluminized Steel - Type I
20
4 — 454 — 56
Redundant - Single Stage
Hot Surface IgnitionMultiport Inshot
4115/1/60
13.8151/2
H x W x D41-3/4 x 23 x 30-1/2
162 / 151
8 Pub. No. 22-1640-13
GeneralData
1 Central Furnace heating designs are certified by AGA and CSA.2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian
applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
MODELTYPE RATINGS 2 Input BTUH Capacity BTUH (ICS) 3 AFUE Temp. rise (Min.-Max.) °F. BLOWER DRIVE Diameter - Width (In.) No. Used Speeds (No.) CFM vs. in. w.g. Motor HP R.P.M. Volts / Ph / Hz COMBUSTION FAN - Type Drive - No. Speeds Motor HP - RPM Volts / Ph / Hz FLA FILTER — Furnished? Type Recommended Hi Vel. (No.-Size-Thk.) VENT — Size (in.) HEAT EXCHANGERType-Fired -Unfired Gauge (Fired) ORIFICES — MainNat. Gas. Qty. — Drill Size L.P. Gas Qty. — Drill Size GAS VALVE PILOT SAFETY DEVICE Type BURNERS — Type Number POWER CONN. — V / Ph / Hz 4 Ampacity (In Amps) Max Overcurrent Protection (Amps) PIPE CONN. SIZE (IN.) DIMENSIONS Crated (In.) WEIGHTShipping (Lbs.) / Net (Lbs)
PRODUCT SPECIFICATIONS 1
TUD1B100A9361AUpflow / Horizontal
100,00079,00080.0
40 - 70DIRECT10 x 7
14
See Fan Performance Table1/3
1075115/1/60
CentrifugalDirect - 1
1/50- 3000115/1/60
1.0No
High Velocity1 - 17x25 - 1in.
4 Round
Aluminized Steel - Type I
20
5 — 455 — 56
Redundant - Single Stage
Hot Surface IgnitionMultiport Inshot
5115/1/60
10.4151/2
H x W x D41-3/4 x 19-1/2 x 30-1/2
151 / 141
TUD1B100A9451AUpflow / Horizontal
100,00079,00080.0
35 - 65DIRECT10 x 8
14
See Fan Performance Table1/3
1075115/1/60
CentrifugalDirect - 1
1/50- 3000115/1/60
1.0No
High Velocity1 - 17x25 - 1in.
4 Round
Aluminized Steel - Type I
20
5 — 455 — 56
Redundant - Single Stage
Hot Surface IgnitionMultiport Inshot
5115/1/60
10.4151/2
H x W x D41-3/4 x 19-1/2 x 30-1/2
153 / 143
TUD1C100A9481AUpflow / Horizontal
100,00079,00080.0
35 - 65DIRECT10 x 8
14
See Fan Performance Table1/2
1075115/1/60
CentrifugalDirect - 1
1/50- 3000115/1/60
1.0No
High Velocity1 - 20x25 - 1in.
4 Round
Aluminized Steel - Type I
20
5 — 455 — 56
Redundant - Single Stage
Hot Surface IgnitionMultiport Inshot
5115/1/60
11.6151/2
H x W x D41-3/4 x 23 x 30-1/2
162 / 151
TUD1C100A9601AUpflow / Horizontal
100,00079,00080.0
30 - 60DIRECT11 x 10
14
See Fan Performance Table1/2
1075115/1/60
CentrifugalDirect - 1
1/50- 3000115/1/60
1.0No
High Velocity1 - 20x25 - 1in.
4 Round
Aluminized Steel - Type I
20
5 — 455 — 56
Redundant - Single Stage
Hot Surface IgnitionMultiport Inshot
5115/1/60
12.8151/2
H x W x D41-3/4 x 23 x 30-1/2
162 / 151
9Pub. No. 22-1640-13
GeneralData
1 Central Furnace heating designs are certified by AGA and CSA.2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian
applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
MODELTYPE RATINGS 2 Input BTUH Capacity BTUH (ICS) 3 AFUE Temp. rise (Min.-Max.) °F. BLOWER DRIVE Diameter - Width (In.) No. Used Speeds (No.) CFM vs. in. w.g. Motor HP R.P.M. Volts / Ph / Hz COMBUSTION FAN - Type Drive - No. Speeds Motor HP - RPM Volts / Ph / Hz FLA FILTER — Furnished? Type Recommended Hi Vel. (No.-Size-Thk.) VENT — Size (in.) HEAT EXCHANGERType-Fired -Unfired Gauge (Fired) ORIFICES — MainNat. Gas. Qty. — Drill Size L.P. Gas Qty. — Drill Size GAS VALVE PILOT SAFETY DEVICE Type BURNERS — Type Number POWER CONN. — V / Ph / Hz 4 Ampacity (In Amps) Max Overcurrent Protection (Amps) PIPE CONN. SIZE (IN.) DIMENSIONS Crated (In.) WEIGHTShipping (Lbs.) / Net (Lbs)
PRODUCT SPECIFICATIONS 1
TUD1D100A9721AUpflow / Horizontal
100,0008000080.0
30 - 60DIRECT11 x 10
14
See Fan Performance Table3/4
1100115/1/60
CentrifugalDirect - 1
1/50 - 3000115/1/60
1.0No
High Velocity1 - 24x25 - 1in.
4 Round
Aluminized Steel - Type I
20
5 — 455 — 56
Redundant - Single Stage
Hot Surface IgnitionMultiport Inshot
5115/1/60
13.1151/2
H x W x D41-3/4 x 26-1/2 x 30-1/2
175 / 163
TUD1C120A9541AUpflow / Horizontal
120,00096,00080.0
35 - 65DIRECT11 x 10
14
See Fan Performance Table1/2
1075115/1/60
CentrifugalDirect - 1
1/50 - 3000115/1/60
1.0No
High Velocity1 - 20x25 - 1in.
4 Round
Aluminized Steel - Type I
20
6 — 456 — 56
Redundant - Single Stage
Hot Surface IgnitionMultiport Inshot
6115/1/60
12.8151/2
H x W x D41-3/4 x 23 x 30-1/2
176 / 164
TUD1D120A9601AUpflow / Horizontal
120,00096,00080.0
30 - 60DIRECT11 x 10
14
See Fan Performance Table1/2
1075115/1/60
CentrifugalDirect - 1
1/50 - 3000115/1/60
1.0No
High Velocity1 - 24x25 - 1in.
4 Round
Aluminized Steel - Type I
20
6 — 456 — 56
Redundant - Single Stage
Hot Surface IgnitionMultiport Inshot
6115/1/60
12.8151/2
H x W x D41-3/4 x 26-1/2 x 30-1/2
186 / 174
TUD1D140A9601AUpflow / Horizontal
140,000111,000
80.040 - 70
DIRECT11 x 10
14
See Fan Performance Table3/4
1075115/1/60
CentrifugalDirect - 1
1/50 - 3000115/1/60
1.0No
High Velocity1 - 24x25 - 1in.
4 Round
Aluminized Steel - Type I
20
7 — 457 — 56
Redundant - Single Stage
Hot Surface IgnitionMultiport Inshot
7115/1/60
13.1151/2
H x W x D41-3/4 x 26-1/2 x 30-1/2
193 / 181
10 Pub. No. 22-1640-13
PerformanceData
FURNACE AIRFLOW (CFM) VS. STATIC PRESSURE (ins. w.g.)
MODEL SPEED TAP 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90
TU-D1A040A9241A
4 -3 -2 -1 -
HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red
1018847716617
1004832701599
982809678575
950779648544
910742610507
860697585463
802644512413
763585452357
660517384294
TU-D1A040A9301A
4 -3 -2 -1 -
HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red
130711721030892
126211401007876
12111100976856
11641053938893
1092996893789
1023937840744
949867779691
869791712630
783707636561
TU-D1A060A9241A
4 -3 -2 -1 -
HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red
1013835712611
997821702596
973800683573
941771655543
901734617505
852689571459
796636516406
731575452345
659506379277
TU-D1A060A9361A
4 -3 -2 -1 -
HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red
142612431042900
138912251039903
134511971027895
129811601005877
12361113973848
11711057931809
1099991879760
1020916817700
934831745629
TUD-1B060A9361A
4 -3 -2 -1 -
HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red
158813291090894
155413181090901
151712991093904
146812681076894
141212281052881
135111861028860
12781135978828
12001072917777
1102988836683
TUD-1B080A9241A
4 -3 -2 -1 -
HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red
1115919772643
1094912767655
1060891750648
1014857722622
956809681577
886747629512
803671565428
708582489325
600478401203
TUD-1B080A9361A
4 -3 -2 -1 -
HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red
139312101046900
138412091052903
136411981047895
133511771033888
129611471008869
12471107963842
11891058928808
1120999873766
1042930808717
TUD-1B080A9481A
4 -3 -2 -1 -
HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red
183913231092788
182113251090783
179613291091780
175613191083768
171013081076758
164112751059737
157312461040719
148012011005647
13921165970630
TUD-1C080A9601A
4 -3 -2 -1 -
HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red
2308200616901437
2281199716911437
2254198716911437
2209196016831434
2163193316741431
2095188816511418
2026184216271404
1950178015561369
1873171814851334
TUD-1B100A9361A
4 -3 -2 -1 -
HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red
147612491020873
146412571046887
144112521058890
140812341050883
136312031028864
13071158990834
12411101936794
11631030866742
1074946780680
TUD-1B100A9451A
4 -3 -2 -1 -
HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red
177113751127780
173113711141815
135513281124829
162413281124822
155612891094796
147912381049749
13921176989681
12961102914593
11911016825485
TUD-1C100A9481A
4 -3 -2 -1 -
HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red
1880166214281208
1846163514211215
1799159814021210
1740155113701193
1669149313261164
1595142412691124
1489134511991073
1381125611171009
126011571022935
TUD-1C100A9601A
4 -3 -2 -1 -
HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red
2181190816211443
2143188816091419
2104186815971395
2053183415821381
2001180015671367
1929174515331335
1856169014981302
1766163114381256
1676157213771209
11Pub. No. 22-1640-13
PerformanceData
FURNACE AIRFLOW (CFM) VS. STATIC PRESSURE (ins. w.g.)
MODEL SPEED TAP 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90TUD1D100A9721A
BOTTOM AND LEFT SIDE RETURN
4 -3 -2 -1 -
HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red
2484 2458 2432 2387 2342SEE
NOTE 1
2275 2208 2125 2041
TUD1D100A9721A 4 -3 -2 -1 -
HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red
2447209717531459
2401208817501456
2356207917481453
2303205317321443
2249202817161434
2173197016901407
2097191216651380
1994183115941335
1892175015231289
TUD1C120A9541A 4 -3 -2 -1 -
HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red
2162188916541427
2130188116431421
2097187316311414
2067183916191400
2037180516061386
1976177615721357
1914174615381327
1833167014831285
1752159314281243
TUD1D120A9601A 4 -3 -2 -1 -
HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red
2135190616461423
21011881416321415
2066185616171407
2036181715961391
2005177715751375
1923172415351338
1840167114941300
1750160214271246
1659153313601192
TUD1D140A9601A 4 -3 -2 -1 -
HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red
2462212817551450
2407211217461446
2351209617361442
2284205417191427
2216201117021411
2143194916561383
2069188716091354
1989179715641298
1908170615181241
Note 1: High speed CFM is based on bottom and left side return option for this model. Medium High, Medium Low, and Low speedtaps for this model do not have improved airflow with the addition of side return.
CFM VS. TEMPERATURE RISE
MODELCubic Feet Per Minute (CFM)
500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 2400
TUD1A040A9241A 59 49 42 37 33 30
TUD1A040A9301A 59 49 42 37 33
TUD1A060A9241A 63 56 49 44
TUD1A060A9361A 56 49 44 40 37 34 32
TUD1B060A9361A 56 49 44 40 37 34 32
TUD1B080A9241A 74 66 59 54
TUD1B080A9361A 59 54 49 46 42
TUD1B080A9481A 59 54 49 46 42 40 37 35 33
TUD1C080A9601A 54 49 46 42 40 37 35 33 31 30 28 27 26
TUD1B100A9361A 67 62 57 53 49
TUD1B100A9451A 62 57 53 49 46 44 41
TUD1C100A9481A 67 62 57 53 49 46 44 41 39 37
TUD1C100A9601A 62 57 53 49 46 44 41 39 37 35 34 32 31
TUD1D100A9721A 62 57 53 49 46 44 41 39 37 35 34 32 31
TUD1C120A9541A 63 59 56 52 49 47 44 42 40
TUD1D120A9601A 59 56 52 49 47 44 42 40
TUD1D140A9601A 69 65 61 58 55 52 49 47 45
12 Pub. No. 22-1640-13
Field Wiring
FIELD WIRING DIAGRAM FOR HEATING ONLY
FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING/COOLING(OUTDOOR SECTION WITHOUT TRANSFORMER)
From Dwg.. 21B341437 Rev. 1
From Dwg.. 21B341436 Rev. 1
13Pub. No. 22-1640-13
Field Wiring
From Dwg.. 21B341422 Rev. 1
From Dwg.. 21B341423 Rev. 1
14 Pub. No. 22-1640-13
Dimensions
TU
D1
OU
TL
INE
DR
AW
ING
(AL
L D
IME
NS
ION
S A
RE
IN IN
CH
ES
)
Ø 1
-5/8
” H
OLE
WIT
H P
LUG
Ø 1
-5/8
” H
OLE
WIT
H P
LUG
Ø 7
/8”
HO
LE W
ITH
PLU
GEL
ECTR
ICA
L C
ON
NEC
TIO
N
(ALT
ERN
ATE)
MO
DE
LD
IM "
A"
DIM
"B
"D
IM "
C"
DIM
"D
"
*UD
1A04
0A92
41A
, *U
D1A
040A
9301
A*U
D1A
060A
9241
A, *
UD
1A06
0A93
61A
14-1
/2"
9-5/
8"13
-1/4
"13
"
*UD
1B06
0A93
61A
, *U
D1B
080A
9241
A*U
D1B
080A
9361
A, *
UD
1B08
0A94
81A
*UD
1B10
0A93
61A
, *U
D1B
100A
9451
A17
-1/2
"9-
5/8"
16-1
/4"
16"
*UD
1C08
0A96
01A
, *U
D1C
100A
9481
A*U
D1C
100A
9601
A, *
UD
1C12
0A95
41A
21"
13-1
/16"
19-3
/4"
19-1
/2"
*UD
1D10
0A97
21A
, *U
D1D
120A
9601
A*U
D1D
140A
9601
A24
-1/2
"15
-5/1
6"23
-1/4
"23
"
15Pub. No. 22-1640-13
ElectricalData
WIRING DIAGRAM FOR GAS FURNACES
Since Trane has a policy of continuous product and product data improvement, it reserves the right to change design and specifications without notice.
Trane6200 Troup HighwayTyler, TX 75707www.trane.com
File No. PL-UN-FURN-TDD-D-1 3/98 04/15
SCHEMATIC DIAGRAM FOR GAS FURNACES