TP3 Cond Steel condensing generator with three flue passes, for oil and gas fuel

Upload: vukiet

Post on 11-Oct-2018

224 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: TP3 Cond - FERROLI · TP3 COND is ideal for systems with high water flow-rates, ... - Includes 2 stages regulation thermostat based on NTC flow probe, safety thermostat - Inputs for

TP3 CondSteel condensing generator with three flue passes, for oil and gas fuel

Page 2: TP3 Cond - FERROLI · TP3 COND is ideal for systems with high water flow-rates, ... - Includes 2 stages regulation thermostat based on NTC flow probe, safety thermostat - Inputs for

> TP3 CONDDESIGNED WITH EXPERIENCE

> THE raNgE

Ferroli’s long history and the experience in the steel boiler business are the strong columns of TP3 COND project.

It’s a very innovative orizontal condensing generator for pressurised combustion with three flue gas passes.

ready for operation in combination with a gas or oil jet burner.

The arrangement and generous sizing of the combustion chamber guarantee a low heating load and the possibility to be combined with burners featuring technology for the combustion with low polluting emissions.

Its very high efficiency and the big volume of water content make the TP3 COND the best solution for the replecement activities or for the new high tech building design.

tp3 cond> > > Heating division

7 Models

TherMal ouTpuT range: 65 / 650 kW

erp Class: a

en 92/42: ★ ★ ★ ★

Working pressure: 6 bar

Max Working TeMperaTure: 100°C

Page 3: TP3 Cond - FERROLI · TP3 COND is ideal for systems with high water flow-rates, ... - Includes 2 stages regulation thermostat based on NTC flow probe, safety thermostat - Inputs for

> TP3 CONDTHINKED FOR DESIGNER

The boiler’s high water content and their large water passages mean that TP3 COND series have very low pressure drop even at high flow-rates, allowing the boiler to work practically at any ΔT between outlet and return-up.

All this ensures considerable installation flexibility, freeing system designers from the limits imposed by the type of boiler.

1CIRCUITS WITH DIFFERENT OPERATING TEMPERATURES

TP3 COND is fitted with a second return connection for operating with a high temperatures system (for example the return from DHW storage) that, being located around half-way up the heat exchanger, avoids raising the average return temperature of the low temperature circuit, while guaranteeing maximum appliance efficiency.

2SYSTEMS WITH MULTI-ZONE DISTRIBUTION CIRCUITS AND SYSTEMS WITH MODULATING CIRCULATION

TP3 COND is ideal for systems with high water flow-rates, operating simultaneously in multiple “zones”. The possibility to work across a practically unlimited range of Δt means the boiler can easily operate in combination with low power, variable-speed circulation systems, bringing advantages in terms of building energy efficiency.

3REPLACEMENT OF EXISTING HEAT GENERATORS

The fact that the TP3 COND is “independent” of the type of system makes it the best solution in terms of performance and technical specifications when replacing old heat generators. Condensation system efficiency makes it perfect for the reduction in energy consumption in according with the actual European rules.

tp3 cond> > > Heating division

MODEL 65 100 150 230 370 500 650Water content (litres) 237 296 349 571 881 1202 1327

Page 4: TP3 Cond - FERROLI · TP3 COND is ideal for systems with high water flow-rates, ... - Includes 2 stages regulation thermostat based on NTC flow probe, safety thermostat - Inputs for

E

F

G

N/O

L

M

KEYA Central heating flue outletB Safety connection C Central heating high

temperature inletD Central heating low

temperature inletE Combustion chamberF Pipe for the second flue gas

accrossG Tubes bundle for the third

flue gas accrossH Preformed insulation on

furnace side and on flue gas reversal side

I Jet burner plate on boardL Door with reversible opening

and adjustment systemM DeflectorsN Rear flue gas chamberO Front and back plate for tube

bundle

> TP3 CONDMANUFACTURED FOR THE TECHNICIAN

tp3 cond> > > Heating division

E

dMcBAI

H

F

G

o

L

n

FOCUS ON...Floating combustion chamber with cooled end plate, small volumetric heating load to ensure very low atmospheric nitrogen oxide emissions in combination with suitable burners.

Pipe for the second flue pass with intake from the bottom of the furnace, sized to optimise combustion parameters and to decrease the load loss of flue gas loop.It’s manufactured in stainless steel (InoX 2205)

On the vertical of the low temperature connection there is a deflector that favors the flow of cold water to the lower part of the boiler body to elevate the efficiency of the heat exchange and favor the condensation process.

Front door has been studied with a reversible opening, both right-hand or left-hand. Special attention has been focused on the insulation, so as to guarantee the smallest heat loss and maximum resistance to high temperatures. The perfect closing of the door is ensured with four lock.

Rear flue gas chamber, the front and back plate for tuble bundle are manufactured in stainless steel(InoX 2205)

Tubes bundle for the third flue gas pass located at the lower part of the hot water generator to increase the condensing process and the efficency of the system. Fitted with steel turbulators to increase convective heat exchange. It’s manufactured in stainless steel (InoX 2205)

Page 5: TP3 Cond - FERROLI · TP3 COND is ideal for systems with high water flow-rates, ... - Includes 2 stages regulation thermostat based on NTC flow probe, safety thermostat - Inputs for

> TP3 CONDCONTROL PANEL

tp3 cond> > > Heating division

TP3COND is macthed with two different type of control panel. Both are complete of the electric system to connect with the boiler, the jet burner and the main heating system components.

Panel is equipped with:

1 Pump ON switch2 Burner ON switch3 Boiler ON switch4 Test button5 Safety button with manual reset6 Boiler water temperature7 Boiler ON LED8 1st stage burner LED 9 2nd stage burnerLED10 Burner lockout LED11 Safety pressure switch LED12 2nd stage control thermostat

TR113 1st stage control thermostat TR114 Housing for optional temperature

controller (not supplied)

THErmOsTaTiC CONTrOl bOarD- Suitable for single or two stages burners- Digital thermometer and LED diagnostic- Pre-set for integration of an electronic controller- Includes 2 stages regulation thermostat based on NTC flow

probe, safety thermostat- Inputs for ambient thermostat, additional safety device (max

2 in series)

THErmO EbmEvOLvED ELECTRONIC CONTROL BOARD- Outdoor temperature compensation- Manages as a standard 2 CH mixed zones, with possible

third direct zone - Daily or weekly central heating and DHW program- Cascade management via bus- Generator and system protection functions- Relays and probe connection settable for several functions (solar,

external heat source, cooling, 0/10 V, various system devices, modulating pump, modulating burner, alarm output, ect)

- Possible installation of additional modules to multiply simultaneous functions management

Page 6: TP3 Cond - FERROLI · TP3 COND is ideal for systems with high water flow-rates, ... - Includes 2 stages regulation thermostat based on NTC flow probe, safety thermostat - Inputs for

tp3 cond> > > Heating division

> TP3 CONDTECHNICAL DATA

MODEL 65 100 150 230 370 500 650

erp class A - - - - - -

Thermal input power(kW)

Max 61,3 94,3 141,5 217 349,1 471,7 613,2Min 18,4 28,3 42,5 65,1 104,7 141,5 184

Thermal output power (80/60°C) (kW)

Max 59,5 91,5 137,3 210,5 338,6 457,5 594,8Min 18 27,7 41,6 63,8 102,6 138,7 180,3

Thermal output power(50/30°C)(kW)

gas Max 65 100 150 230 370 500 650Min 19,7 30,3 45,4 69,7 112 151,4 196,8

oilMax 62,9 96,7 145 222,4 357,8 483,5 628,5Min 19,1 29,4 44,2 67,7 108,9 147,2 191,3

efficency (50/30°C)(%)

gas Max 106 106 106 106 106 106 106Min 107 107 107 107 107 107 107

oilMax 102,5 102,5 102,5 102,5 102,5 102,5 102,5Min 104 104 104 104 104 104 104

efficency30%

gas Max 107,5 107,5 107,5 107,5 107,5 107,5 107,5oil Min 104,5 104,5 104,5 104,5 104,5 104,5 104,5

Maximun operating pressure bar 6 6 6 6 6 6 6loss pressure water side mbar 0,4 0,65 1,7 1,7 2 3,5 4,2protection rating ipx0d electrical power supply V/hz 230/50 230/50 230/50 230/50 230/50 230/50 230/50 empty weight kg 377 436 490 645 1035 1338 1451

MODEL 65 100 150 230 370 500 650

dimensions

a mm 700 700 700 800 950 1050 1050 b mm 1437 1437 1437 1637 1462 1462 1462 C mm 1157 1377 1577 1777 1987 2187 2387 d mm 650 650 650 750 900 1000 1000 e mm 1275 1275 1275 1475 1655 1805 1805 g mm 1335 1335 1335 1535 1715 1860 1860 h mm 878 1098 1298 1498 1698 1900 2100 i mm 123 123 123 142 172 179 179 J mm 200 260 350 400 450 500 600 k mm 200 300 320 400 450 500 600 l mm 200 260 350 400 450 500 500 M mm 155 155 155 156 176 221 221 n mm 157 157 157 157 167 167 167 o mm 122 122 122 122 122 120 120 p mm 846 1066 1266 1467 1667 1867 2067 Q mm 134 134 134 134 144 144 144 s mm 80 80 80 80 70 70 70 V mm 450 443 435 500 550 587 580 W mm 905 905 905 1055 1200 1315 1315

Central heating outlet T1 dn 50 dn 50 dn 50 dn 65 dn 80 dn 100 dn 100 high temperature Ch inlet T2 dn 40 dn 40 dn 40 dn 40 dn 50 dn 65 dn 65 low temperature Ch inlet T3 dn 50 dn 50 dn 50 dn 65 dn 80 dn 100 dn 100 safety connection T4 dn 40 dn 40 dn 40 dn 40 dn 50 dn 65 dn 65 boiler drain T5 1” 1” 1” 1” 1” 1” 1”

Flue outlet T6 Øe mm 160 160 160 200 250 300 300

Page 7: TP3 Cond - FERROLI · TP3 COND is ideal for systems with high water flow-rates, ... - Includes 2 stages regulation thermostat based on NTC flow probe, safety thermostat - Inputs for

tp3 cond> > > Heating division

> TP3 CONDTECHNICAL DATA / PRESSURE LOSSES / COUPLING

FErrOLi LaMbOrGhiNi caLOrbOiLEr OiL bUrNEr GaS bUrNErMODEL cODE MODEL TYPE cODE MODEL TYPE cODE

tp3 cond 65 0RGZ3AXAeCo 8 one stage 00870013 eM 9-e.d2 one stage 00860301

eCo 7/2 Two stage 00840381eM 9-e.d3 one stage 00860311eM 9/2-e.d3 Two stage 00860322

tp3 cond 100 0RGZ4AXA eCo 10/l one stage 00845650

eM 12/l-e.d3 one stage 00873030eM 12/l-e.d6 one stage 00873020eM 16/2-e.d4 Two stage 00860421eM 16/2-e.d6 Two stage 00860431eM 16/M-e.d4 Two stage progressive 00872210

tp3 cond 150 0RGZ5AXA

eCo 22 one stage 00840602eM 26/2-e.d4 Two stage 00860551eM 26/2-e.d6 Two stage 00860531

eCo 22/2 Two stage 00840654eM 26/M-e.d4 Two stage progressive 00860581eM 26/M-e.d5 Two stage progressive 00860591eM 26/M-e.d7 Two stage progressive 00860571

tp3 cond 230 0RGZ8AXA

eCo 22 one stage 00840602eM 40/2-e.d4 Two stage 00870262eM 40/2-e.d7 Two stage 00870252eM 40/M-e.d4 Two stage progressive 00870302

eCo 22/2 Two stage 00840654eM 40/M-e.d5 Two stage progressive 00870312eM 40/M-e.d7 Two stage progressive 00870292eM 40/2-e.d4 Two stage 00870262

tp3 cond 370 0RGZBAXA eCo 40/2 Two stage 00870171 lMb g 450-k1 (VCV-l225) Two stage progressive 00873810

tp3 cond 500 0RGZdAXA lMb lo 700 bl Two stage 00845881lMb g 700 (bl) (k1"1/2) Two stage progressive 00873541lMb g 700-k1 (VCV-l125) Two stage progressive 00873531

tp3 cond 650 0RGZGAXA lMb lo 1000 (2sT-bl) Two stage 00845301lMb g 1000 (bl) (k2") Two stage progressive 00872591lMb g 1000 (bl) (s1 1/2") Two stage progressive 00872690

RECOMMENDED COUPLING TP3 COND WITH LAMBORGHINI CALOR BURNER

It’s possible to find every other information about the burners (technical features, configuration, kits...) on Lamborghini Calor technical and commercial documentations

PRESSURE LOSSES MOD. 65 100 150 230 370

TP3 COND 65÷230 TP3 COND 370÷650

PRESSURE LOSSES MOD. 500 650

KEY

1 Instrument panel2 Burner

connection flange3 Smoke chamber

cleaning door4 Flame control

sight glass5 Lifting hooks6 Holes for lifting

hookT1 Heating deliveryT2 High temperature

returnT3 Low temperature

returnT4 Expansion vessel

connectionT5 Boiler discharge

connectionT6 Flue connectionT7 Condensate

discharge connection

Page 8: TP3 Cond - FERROLI · TP3 COND is ideal for systems with high water flow-rates, ... - Includes 2 stages regulation thermostat based on NTC flow probe, safety thermostat - Inputs for

cod.

89a

g404

0/00

- 08

.201

7NOTICE FOR DEALERS:As part of its efforts to constantly improve its range of products, with the aim of increasing the level of customer satisfaction, the company stresses that the appearance, dimensions, technical data and accessories may be subject to variation.

Consequently, ensure that the customer is provided with up-to-date technical and/or sales documents.

Ferroli spa37047 San Bonifacio (VR) Italy - Via Ritonda 78/Atel. +39.045.6139411fax [email protected]