top view bottom view top wiring interconnet …...battery cabinet (floor mounting) front view...

3
1 A 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 A2 B C D E F G H A B C D E F G H "B" 2281 89.8 [ ] 2055 80.9 [ ] 650 25.6 [ ] 530 20.9 [ ] "A" "C" 410 16.1 [ ] 529 20.8 [ ] 650 25.6 [ ] 465 18.3 [ ] REF 57 2.2 [ ] WEIGHT AND CENTER OF GRAVITY (INSTALLED) A B C WEIGHT kg (lbs) 128S 325 [12.8] 263.8 [10.4] 1027.5 [40.5] 482 [1063] 136S 325 [12.8] 263.8 [10.4] 1027.5 [40.5] 500 [1102] PACKAGED RACK DIMENSIONS PALLET WIDTH PALLET DEPTH OVERALL HEIGHT 1110 [43.7] 1130 [44.5] 2190 [86.2] PRODUCT SPECIFICATIONS BATTERY CABINET MODEL DC VOLTAGE OUTPUT, V (NOMINAL) BATTERY NAMEPLATE kWh 128S1P 486.4 V 32.6 kWh 136S1P 516.8 V 34.6 kWh HEAT OUTPUT: 567 BTU TOP WIRING INTERCONNECT ASSEMBLY 128S1P P-103003835 136S1P P-103003836 EATON CORPORATION - CONFIDENTIAL AND PROPRIETARY. NOTICE TO PERSONS RECEIVING THIS DOCUMENT AND/OR TECHNICAL INFORMATION THIS DOCUMENT, INCLUDING THE DRAWING AND INFORMATION CONTAINED THEREON, IS CONFIDENTIAL AND IS THE EXCLUSIVE PROPERTY OF EATON CORPORATION, AND IS MERELY ON LOAN AND SUBJECT TO RECALL BY EATON AT ANY TIME. BY TAKING POSSESSION OF THIS DOCUMENT, THE RECIPIENT ACKNOWLEDGES AND AGREES THAT THIS DOCUMENT CANNOT BE USED IN ANY MANNER ADVERSE TO THE INTERESTS OF EATON AND THAT NO PORTION OF THIS DOCUMENT MAY BE COPIED OR OTHERWISE REPRODUCED WITHOUT THE PRIOR WRITTEN CONSENT OF EATON. IN THE CASE OF CONFLICTING CONTRACTUAL PROVISIONS, THIS NOTICE SHALL GOVERN THE STATUS OF THIS DOCUMENT. © 2019 Eaton Corporation - All Rights Reserved. SHEET: 1 OF 3 ECO: ECO-176039 SEE NOTES FOR TOLERANCES DIM ARE IN MM (INCHES) AFTER PLATING INTERPRET DIM AND TOL PER ASME Y14.5-2018 18-NOV-2019 MODIFIED BY: V. Mule SCALE: 1:10 STATE: Release 18-NOV-2019 ORIGINATED BY: MULE_V SIZE: A2 DESCRIPTION: SAMSUNG UL9540a BATTERY CABINET SITE PLAN REVISION: 01 NAME (PART NUMBER): P-110000740 THIRD ANGLE PROJECTION METRIC NOTES 1. THE SYSTEM MUST BE INSTALLED ON A LEVEL FLOOR SURFACE SUITABLE FOR COMPUTER OR ELECTRONIC EQUIPMENT. 2. THE SYSTEM MUST BE INSTALLED IN A TEMPERATURE AND HUMIDITY CONTROLLED INDOOR AREA FREE OF CONDUCTIVE CONTAMINANTS. 3. AMBIENT TEMPERATURE RANGE 18-28degC [64-83degF], RELATIVE HUMIDITY: 5%-95% NON-CONDENSING. 4. WEIGHT: WEIGHTS DO NOT INCLUDE CUSTOMER WIRING. 5. MINIMUM 914mm [36"] FRONT ACCESS NEEDED FOR SERVICING. 6. VENTILATION IS BY MEANS OF NATURAL CONVECTION 7. ALL WIRING IS TO BE IN ACCORDANCE WITH NATIONAL AND LOCAL ELECTRIC CODES. 8. POWER HOOKUP TO UPS: POSITIVE, NEGATIVE, GROUND. 9. SPECIFICATIONS ARE SUBJECT TO CHANGE. 10. ALL DIMENSIONS ARE IN MILLIMETERS [INCHES]. TOP VIEW TOP WIRING INTERCONNET ASSEMBLY / BATTERY CABINET BOTTOM VIEW BATTERY CABINET (FLOOR MOUNTING) FRONT VIEW TOP-WIRING INTERCONNECT ASSEMBLY * FIELD INSTALLED * ASSEMBLY VENTILATION INTER-CABINET CONTROL WIRING ACCESS (BOTH SIDES) INTER-CABINET POWER WIRING ACCESS (BOTH SIDES) SIDE VIEW REAR VIEW TOP-WIRING INTERCONNECT CONDUIT ACCESS (ACCESS AREA: 600 [23.6] X 155 [6.1]) SECURE CABINET TO FLOOR WITH M16 OR 5/8" BOLTS (4X CORNERS) ** CUSTOMER SUPPLIED ** Page: 1 of 3

Upload: others

Post on 18-Apr-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

1

A

2 3 4 5 6 7 8 9 10 11 12

1 2 3 4 5 6 7 8 9 10 11 A2

B

C

D

E

F

G

H

A

B

C

D

E

F

G

H

"B"

228189.8[ ]

205580.9[ ]

65025.6[ ]

53020.9[ ]

"A"

"C"

41016.1[ ]

52920.8[ ]

65025.6[ ]

46518.3[ ]

REF57 2.2[ ]

WEIGHT AND CENTER OF GRAVITY (INSTALLED)

A B CWEIGHT

kg (lbs)

128S 325 [12.8] 263.8 [10.4] 1027.5 [40.5] 482 [1063]

136S 325 [12.8] 263.8 [10.4] 1027.5 [40.5] 500 [1102]

PACKAGED RACK DIMENSIONS

PALLETWIDTH

PALLETDEPTH

OVERALLHEIGHT

1110 [43.7] 1130 [44.5] 2190 [86.2]

PRODUCT SPECIFICATIONS

BATTERY CABINET MODEL

DC VOLTAGE OUTPUT,

V (NOMINAL)

BATTERY NAMEPLATE

kWh

128S1P 486.4 V 32.6 kWh

136S1P 516.8 V 34.6 kWh

HEAT OUTPUT: 567 BTU

TOP WIRING INTERCONNECTASSEMBLY

128S1P P-103003835

136S1P P-103003836

EATON CORPORATION - CONFIDENTIAL AND PROPRIETARY. NOTICE TO PERSONS RECEIVING THIS DOCUMENT AND/OR TECHNICAL INFORMATIONTHIS DOCUMENT, INCLUDING THE DRAWING AND INFORMATION CONTAINED THEREON, IS CONFIDENTIAL AND IS THE EXCLUSIVE PROPERTY OF EATON CORPORATION, AND IS MERELY ON LOAN AND SUBJECT TO RECALL BY EATON AT ANY TIME. BY TAKING POSSESSION OF THIS DOCUMENT, THE RECIPIENT ACKNOWLEDGES AND AGREES THAT THIS DOCUMENT CANNOT BE USED IN ANY MANNER ADVERSE TO THE INTERESTS OF EATON AND THAT NO PORTION OF THIS DOCUMENT MAY BE COPIED OR OTHERWISE REPRODUCED WITHOUT THE PRIOR WRITTEN CONSENT OF EATON. IN THE CASE OF CONFLICTING CONTRACTUAL PROVISIONS, THIS NOTICE SHALL GOVERN THE STATUS OF THIS DOCUMENT. © 2019 Eaton Corporation - All Rights Reserved.

SHEET: 1 OF 3ECO: ECO-176039

SEE NOTES FOR TOLERANCESDIM ARE IN MM (INCHES) AFTER PLATINGINTERPRET DIM AND TOL PER ASME Y14.5-201818-NOV-2019MODIFIED BY: V. Mule

SCALE: 1:10STATE: Release18-NOV-2019ORIGINATED BY: MULE_V

SIZE: A2DESCRIPTION: SAMSUNG UL9540a BATTERY CABINET SITE PLAN

REVISION: 01NAME (PART NUMBER):

P-110000740THIRD ANGLE PROJECTION

METRIC

NOTES1. THE SYSTEM MUST BE INSTALLED ON A LEVEL FLOOR SURFACE SUITABLE FOR COMPUTER OR ELECTRONIC EQUIPMENT.2. THE SYSTEM MUST BE INSTALLED IN A TEMPERATURE AND HUMIDITY CONTROLLED INDOOR AREA FREE OF CONDUCTIVE CONTAMINANTS.3. AMBIENT TEMPERATURE RANGE 18-28degC [64-83degF], RELATIVE HUMIDITY: 5%-95% NON-CONDENSING.4. WEIGHT: WEIGHTS DO NOT INCLUDE CUSTOMER WIRING.5. MINIMUM 914mm [36"] FRONT ACCESS NEEDED FOR SERVICING.6. VENTILATION IS BY MEANS OF NATURAL CONVECTION 7. ALL WIRING IS TO BE IN ACCORDANCE WITH NATIONAL AND LOCAL ELECTRIC CODES.8. POWER HOOKUP TO UPS: POSITIVE, NEGATIVE, GROUND.9. SPECIFICATIONS ARE SUBJECT TO CHANGE.10. ALL DIMENSIONS ARE IN MILLIMETERS [INCHES].

TOP VIEWTOP WIRING INTERCONNET

ASSEMBLY / BATTERY CABINET

BOTTOM VIEWBATTERY CABINET(FLOOR MOUNTING)

FRONT VIEW

TOP-WIRING INTERCONNECT

ASSEMBLY* FIELD INSTALLED *

ASSEMBLYVENTILATION

INTER-CABINET CONTROL WIRING ACCESS(BOTH SIDES)

INTER-CABINET POWERWIRING ACCESS(BOTH SIDES)

SIDE VIEW REAR VIEW

TOP-WIRING INTERCONNECT CONDUIT ACCESS

(ACCESS AREA:600 [23.6] X 155 [6.1]) SECURE CABINET TO FLOOR

WITH M16 OR 5/8" BOLTS(4X CORNERS)

** CUSTOMER SUPPLIED **

Page: 1 of 3

1

A

2 3 4 5 6 7 8 9 10 11 12

1 2 3 4 5 6 7 8 9 10 11 A2

B

C

D

E

F

G

H

A

B

C

D

E

F

G

H

CUSTOMER SUPPLIED WIRING, TOP INTERCONNECT ASSEMBLY

RECOMMENDED MINIMUM WIRE SIZE FOR 75 deg C COPPER STRANDED WIRE

RECOMMENDED TORQUE

BATTERY WIRES 3/0 AWG (2X PER POLE) 519 IN-LB

GROUND WIRES 3/0 AWG 519 IN-LB

CONTROL WIRES (TB1) 18 AWG 5 IN-LB

480 VAC AUX POWER (TB2)(2 SOURCES)**

14 AWG 10 IN-LB

CONTROL WIRING TO UPS (TB1)

TB1-1 MCCB NORMALLY OPEN

TB1-2 MCCB COMMON

TB1-3 MAJOR ALARM NORMALLY OPEN

TB1-4 MAJOR COMMON

TB1-5 MINOR ALARM NORMALLY OPEN

TB1-6 MINOR COMMON

TB2-7INPUT, OPEN BREAKER,CONTACT CLOSE >3 SEC

TB1-8GND, OPEN BREAKER,CONTACT CLOSE >3 SEC

TB1-9 NOT USED

TB1-10 NOT USED

480 VAC AUX POWER (TB2)

TB2-1 SOURCE 1 L1

TB2-2 SOURCE 1 L2

TB2-3 SOURCE 1 L3

TB2-4 SOURCE 1 PE

TB2-5 SOURCE 2 L1

TB2-6 SOURCE 2 L2

TB2-7 SOURCE 2 L3

TB2-8 SOURCE 2 PE

*14 AWG AC AUXILIARY POWERSHOULD BE PROTECTED BY A LISTED15A BREAKER OR FUSE.

TOP WIRING INTERFACE BOXASSEMBLY

480 VAC UPS APPLICATIONS

P-103003825

208/220 VAC UPS APPLICATIONS

P-103003826

EATON CORPORATION - CONFIDENTIAL AND PROPRIETARY. NOTICE TO PERSONS RECEIVING THIS DOCUMENT AND/OR TECHNICAL INFORMATIONTHIS DOCUMENT, INCLUDING THE DRAWING AND INFORMATION CONTAINED THEREON, IS CONFIDENTIAL AND IS THE EXCLUSIVE PROPERTY OF EATON CORPORATION, AND IS MERELY ON LOAN AND SUBJECT TO RECALL BY EATON AT ANY TIME. BY TAKING POSSESSION OF THIS DOCUMENT, THE RECIPIENT ACKNOWLEDGES AND AGREES THAT THIS DOCUMENT CANNOT BE USED IN ANY MANNER ADVERSE TO THE INTERESTS OF EATON AND THAT NO PORTION OF THIS DOCUMENT MAY BE COPIED OR OTHERWISE REPRODUCED WITHOUT THE PRIOR WRITTEN CONSENT OF EATON. IN THE CASE OF CONFLICTING CONTRACTUAL PROVISIONS, THIS NOTICE SHALL GOVERN THE STATUS OF THIS DOCUMENT. © 2019 Eaton Corporation - All Rights Reserved.

SHEET: 2 OF 3ECO: ECO-176039

SEE NOTES FOR TOLERANCESDIM ARE IN MM (INCHES) AFTER PLATINGINTERPRET DIM AND TOL PER ASME Y14.5-201818-NOV-2019MODIFIED BY: V. Mule

SCALE: 1:20STATE: Release18-NOV-2019ORIGINATED BY: MULE_V

SIZE: A2DESCRIPTION: SAMSUNG UL9540a BATTERY CABINET SITE PLAN

REVISION: 01NAME (PART NUMBER):

P-110000740THIRD ANGLE PROJECTION

METRIC

**NOTE:1. EACH TYPE S BATTERY SYSTEM REQUIRES A MINIMUM OF ONE 400-500 VAC THREE-PHASE CIRCUIT TO PROVIDE AUXILIARY POWER TO THE SYSTEM BMS.2. FOR 480 VAC UPS APPLICATIONS, THE BATTERY CABINET IS WIRED DIRECTLY TO A 480 VAC SOURCE.3. FOR 208/220 VAC UPS APPLICATIONS, THE TOP WIRING KIT INCLUDES TRANSFORMERS TO STEP UP TO 480 VAC.4. THESE CIRCUITS MUST BE PROVIDED FROM THE CUSTOMER'S ELECTRICAL DISTRIBUTION AND SHOULD BE PROTECTED BY A LISTED 15A DEVICE (CIRCUIT BREAKER OR FUSE), WITH A RECOMMENDED WIRE SIZE OF 14 AWG.5. SOURCE 1 (REQUIRED) SHALL BE PROVIDED FROM THE UPS OUTPUT DISTRIBUTION; SOURCE 2 (OPTIONAL) SHALL BE PROVIDED FROM THE UPS BYPASS INPUT.6. FOR PARALLEL BATTERY CABINETS, THE AC SOURCES CAN BE PROVIDED TO ONLY THE "MASTER" CABINET TOP WIRING KIT AND FROM THERE TO THE PARALLEL CABINETS USING THE SUPPLIED INTERCONNECT HARNESSING.

TERMINAL BLOCK (TB-1)

TERMINAL BLOCK (TB-2)

FRONT

**COVER AND BUS BAR INSULATORSREMOVED FOR CLARITY**

TOP WIRINGINTERCONNECT ASSEMBLYNOTE:

RECOMMEND 3/0 COMPRESSION LUGTHOMAS & BETTS CATALOG# 54265

SCALE 3:2

SCALE 1:1

SEE DETAIL A

DC BUS JUMPERS TO SWITCHGEAR

14 AWG HARNESS CONNECTING TB-1 & TB-2 WITH AUTO TRANSFORMER(P-152002119)

(FOR 208/220V ONLY)

DC(-)

TERMINAL BLOCKTB-2

DC(+)

DETAIL ASCALE 1:4

TERMINAL BLOCK TB-1

TRANSFORMERS (QTY. 2)FOR 208/220V ONLY

GROUNDING HOLES1.75" SPACING

Page: 2 of 3

1

A

2 3 4 5 6 7 8 9 10 11 12

1 2 3 4 5 6 7 8 9 10 11 A2

B

C

D

E

F

G

H

A

B

C

D

E

F

G

H

EATON CORPORATION - CONFIDENTIAL AND PROPRIETARY. NOTICE TO PERSONS RECEIVING THIS DOCUMENT AND/OR TECHNICAL INFORMATIONTHIS DOCUMENT, INCLUDING THE DRAWING AND INFORMATION CONTAINED THEREON, IS CONFIDENTIAL AND IS THE EXCLUSIVE PROPERTY OF EATON CORPORATION, AND IS MERELY ON LOAN AND SUBJECT TO RECALL BY EATON AT ANY TIME. BY TAKING POSSESSION OF THIS DOCUMENT, THE RECIPIENT ACKNOWLEDGES AND AGREES THAT THIS DOCUMENT CANNOT BE USED IN ANY MANNER ADVERSE TO THE INTERESTS OF EATON AND THAT NO PORTION OF THIS DOCUMENT MAY BE COPIED OR OTHERWISE REPRODUCED WITHOUT THE PRIOR WRITTEN CONSENT OF EATON. IN THE CASE OF CONFLICTING CONTRACTUAL PROVISIONS, THIS NOTICE SHALL GOVERN THE STATUS OF THIS DOCUMENT. © 2019 Eaton Corporation - All Rights Reserved.

SHEET: 3 OF 3ECO: ECO-176039

SEE NOTES FOR TOLERANCESDIM ARE IN MM (INCHES) AFTER PLATINGINTERPRET DIM AND TOL PER ASME Y14.5-201818-NOV-2019MODIFIED BY: V. Mule

SCALE: 1:20STATE: Release18-NOV-2019ORIGINATED BY: MULE_V

SIZE: A2DESCRIPTION: SAMSUNG UL9540a BATTERY CABINET SITE PLAN

REVISION: 01NAME (PART NUMBER):

P-110000740THIRD ANGLE PROJECTION

METRIC

MODULE 2

-

MODULE 4

MODULE 6

-

+

MODULE 8

MODULE 10

-

+MODULE 12

MODULE 14

-

+

MODULE 16 MODULE 1

MODULE 3

MODULE 5

MODULE 7

MODULE 9

MODULE 11

MODULE 13

MODULE 15

-

+

+

-

+

-

+

-

+

+

-

+-

+

-

+-

+

-

+

-

+

-

128S CONFIGURATIONBATTERY CABINET

ONE LINE

DC BREAKER

+

-

-DC+DC

-

-

+

-

+

-

+

-

+

+

-

+

-

+

-

+

+

-

+-

+

-

+-

+

-

+

-

+

-

136S CONFIGURATIONBATTERY CABINET

ONE LINE

DC BREAKER

+

-

-DC+DC

MODULE 17

+

-

MODULE 2

MODULE 4

MODULE 6

MODULE 8

MODULE 1

MODULE 3

MODULE 5

MODULE 7

MODULE 10

MODULE 12

MODULE 14

MODULE 16

MODULE 9

MODULE 11

MODULE 13

MODULE 15

Page: 3 of 3