PROPOSAL The facility proposed by Telstra comprises a 60m guyed mast with a 3m extension, six (6) panel antennas mounted on a triangular headframe on the proposed mast, two parabolic antennas mounted on the mast, one equipment shelter at ground level and one (1) GPS antenna mounted on the equipment shelter, together with cabling and ancillary equipment, including nine (9) radio remote units and three (3) tower mounted amplifiers. The components of the proposal are summarised as follows: Component Guyed mast Guyed mast extension Panel antennas Parabolic Antenna Parabolic Antenna GPS Antenna Equipment shelter Total structure Quantity 1 1 6 1 1 1 1 1 Dimensions per unit N/A 2533mm (h) x 350mm (w) x 208mm (d) 01200mm 01200mm 96mm (h) x 068mm 3000mm (I) x 2500mm (w) x 2750mm (h) N/A Height (AGL) 60.00m 3.00m 62.30m 4, 59.40m t, 55.00m ^ 3.1m AGL 63.30m overall The proposed facility will be contained within the existing fenced compound measuring in 10m x 10m size. The monopole will be of a non-reflective galvanised finish which is considered the least obtmsive finish. The proposed equipment shelter will be of pale eucalypt finish. The facility will also reserve space on the monopole for future emergency services organisations infrastructure. Detailed plans and elevations depicting the proposal are attached

Upload: others

Post on 25-Jul-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: together with cabling and ancillary equipment, including ... · The facility proposed by Telstra comprises a 60m guyed mast with a 3m extension, six (6) panel antennas ... together

PROPOSAL

The facility proposed by Telstra comprises a 60m guyed mast with a 3m extension, six (6) panel antennasmounted on a triangular headframe on the proposed mast, two parabolic antennas mounted on the mast,one equipment shelter at ground level and one (1) GPS antenna mounted on the equipment shelter,together with cabling and ancillary equipment, including nine (9) radio remote units and three (3) towermounted amplifiers.

The components of the proposal are summarised as follows:

Component

Guyed mast

Guyed mast extension

Panel antennas

Parabolic Antenna

Parabolic Antenna

GPS Antenna

Equipment shelter

Total structure

Quantity

1

1

6

1

1

1

1

1

Dimensions per unit

N/A

2533mm (h) x 350mm (w) x 208mm (d)

01200mm

01200mm

96mm (h) x 068mm

3000mm (I) x 2500mm (w) x 2750mm (h)

N/A

Height (AGL)

60.00m

3.00m

62.30m 4,

59.40m t,

55.00m ^

3.1m

AGL

63.30m overall

The proposed facility will be contained within the existing fenced compound measuring in 10m x 10msize. The monopole will be of a non-reflective galvanised finish which is considered the least obtmsivefinish. The proposed equipment shelter will be of pale eucalypt finish.

The facility will also reserve space on the monopole for future emergency services organisationsinfrastructure.

Detailed plans and elevations depicting the proposal are attached

Page 2: together with cabling and ancillary equipment, including ... · The facility proposed by Telstra comprises a 60m guyed mast with a 3m extension, six (6) panel antennas ... together

Photograph 1 - View of the subject site (left) looking north along Johnson Road

Photograph 2 - View from subject site looking north

Photograph 3 - View of the subject site's surroundings looking west

Page 3

Page 3: together with cabling and ancillary equipment, including ... · The facility proposed by Telstra comprises a 60m guyed mast with a 3m extension, six (6) panel antennas ... together

B

DO NOTSCALE

77Y

TN

t

EXISTING SMALL TOWER OTHERS -

EXISTING WESTERN POWER SINGLE •PHASE 0/H POWER LINE

EXISTING WESTERN POWER POLE #8480038

PROPOSED WESTERN POWER MINI PILLAR •

PROPOSED TELSTRA COMPOUNDAREA TO BE LEVELLED WITH CUT& FILL AS REQUIRED

JOHNSON ROAD

WPOSED TELSTRA LEASE AREA0"0 •.<->&„ ^ "0

00

S5

°0 0 c?_^5:

~^/ '^y/ ^S~/ '/^'/^//^//^'7'//~T/^7'/^7'/f:/ y/if^^/i/', /s\/rf / / / /^ R/^YyfV / /v /"/\/_/ /TV~W //\>'/^/_/ifJ/ //>'/"//1^/9, /.'"' '.< r/''\' c,',1,' "'A'!0/'''v •'^ ^/w//

\/ /9 / /'/ R/ ^/ /ei / /'//<^///^//^/^//

'^.

^sco

g0a:Q-

' /y/At^,/ / ^/.: /> / /VIW / /y//-y / /\/ / /<y /„/ /^y /^/ /\/ / 4y ^ ^ ^ ^0 <G^^ ^7'0f ^ /

\//^//^//y/9'/^//y////// w/ /^ / /c^ /^/_////Y^///v// /^/ ^ / /(^/o /^ / ^/ ^y / / <

/j^f/<y//////; / ^ f,/ /^/ /y /^y /y~/ / / /ir/I'/ >% v'^y/ /'/ /> <y'/ '/'»6w'/i/ / ^jfY/ /^y // // ^/ /7 ?74-/ / / / ^

',// /-^ / / w/fi/ / / Y./'s/'y/ / / / <iy /./-A^' ./?fc^./^-^^L-'.Y-A^/—t-^. /—^. /—*-/. ^

"0 00" 0 %%0 °

- EXISTING WATER TANKS (P^P.)

•EXISTING GATE

-EXISTING CONSUMER POLE WITH MSB

- EXISTING POWER POLE #8480042 WITHSINGLE PHASE TRANSFORMER

0c00

SITE ACCESS

-EXISTING TREES (TYP.)

-EXISTING PROPERTY BOUNDARY AND FENCE LINE

- PROPOSED TELSTRA WP POWERCABLE ROUTE (APPROX. 90m) TBC

- PROPOSED TELSTRA 3m WIDE ACCESSGATE ON BOUNDARY FENCE

-PROPOSED TELSTRA ACCESS TRACK (APPROX. 50m)

• PROPOSED TELSTRA SITE. REFER TOSHEET 31-1 FOR SITE LAYOUT

- PROPOSED VEGETATION TO BE REMOVEDINSIDE AND AROUND THE COMPOUND AREA

SCALE 1:200020m 0 20m 40m 60m 80m mm SCALE 1:2000

J:—RFNSA SITE No. 6632001

|A

COPYRIGHT © WHEREIS® REGISTERED TRADEMARK OF SENSIS PTY LTD.

LOCALITY PLANNOT TO SCALE

SERVICES LEGENDE

FE

E

FE

— — E — — — EFE — — — FE

-T——T——T-—

ABOVE GROUND ELECTRICAL SUPPLYABOVE GROUND FEEDER CABLESBELOW GROUND ELECTRICAL SUPPLYBELOW GROUND FEEDER CABLESOPTIC FIBRE BELOW GROUND

t>

NOTES:1. ALL EXTERNAL FEEDERS AND TAILS MUST BE BIRD PROOFED AS PEREXTERNAL PLANT POLICY 003615.2. ALL DIMENSIONS ARE IN MILLIMETRES UNLESS SPECIFIED OTHERWISE.3. THIS DRAWING SET IS A PRELIMINARY DRAWING ONLY AND IS ISSUEDFOR COMMENT. IT IS NOT A DETAILED SURVEY / STRUCTURAL DRAWINGAND THEREFORE COULD BE SUBJECT TO CHANGE.4. FOR EME SIGNS NOTED THUS(#XJ REFER TO 005486 FOR DETAILS.QPROPOSED TELSTRA LEASE AREA5. CLEAR ALL VEGETATION WITHIN THE COMPOUND TO MINIMISE SNAKEACTIVITY.

ID

NOTE: THIS DRAWING TO BE READ IN CONJUNCTION WITH SHEETS S1-1 & 81-2 PRELIMINARY

PROPERTY DESCRIPTIONPART OF LOT 6061 ON DP226750, VOL 1155 FOLIO 479CIP^ OF GREATER GERALDTON

SITE STRUCTURE CO-ORDINATES (GDA94)GPS READING ACCURACY: ± 10m

CENTRE OF MAST

LATITUDE

LONGITUDE

GDA94-28.53583

GDA94115.26280

service I; I.';.)' I ! ! I.MORHE(:l)MM(INK';\TIO('IS

Level 3, 7-9 Tanunda Drive, Rivervale WA 6103

T +61 8 9355 7500 I F +61 8 9355 5100 | www.sereicestream.com.au

ORDER DRAWNBL PRELIMINARY - 30064619W0230SSMC - WCDMA850 /LTE700

AMENDMENT EXAMJK

APPD DATE24.11.17

©Telstra Corporation Limited ABN 33 051 775 556 All rights reserved.

^elstraMOBILE NETWORK SITE 316700

TENINDEWA(YUNAROAD)SITE ACCESS AND LOCALITY PLAN

LOT 6061 JOHNSON ROAD, TENINDEWA, WA 6632

DWGNO. W108607 SHT 81

NO.

3. \/ |Cadfile:W108607.dwg 6 ~A3_

The coovriaht and ownersfiio of the drawinas is to be assianed to TeSstra

Page 4: together with cabling and ancillary equipment, including ... · The facility proposed by Telstra comprises a 60m guyed mast with a 3m extension, six (6) panel antennas ... together

D

DO NOTSCALE

77Y

TN

IA

10000

PROPOSED TELSTRAWP POWER-CABLE ROUTE (APPROX. 90m) TBC

PROPOSED WESTERN POWER MINI PILLAR(SUBJECTED TO WP DESIGN)

PROPOSED TELSTRA U/G SUBMAINS •FROM PILLAR

PROPOSED VEGETATION TO BE REMOVED -INSIDE AND AROUND THE COMPOUND AREA

PROPOSED TELSTRA 450W CABLE LADDER •TO ACCOMMODATE PROPOSED TELSTRAFEEDERS(5 OFF)

PROPOSED TELSTRA GPS ANTENNA(1 OFF A12)MOUNTED ON PROPOSED ANTENNA BRACKETNEAR FEEDER WINDOW ON SHELTER ROOF

PROPOSED TELSTRA MAST BASEFOOTING (SHOWN INDICATIVELY)

#6 I 1.5m AGL

PROPOSED TELSTRA 60m HIGH WITH3m EXTENSION 750 F/W GUYED MAST

PROPOSED SIGN SECURED TOTELSTRA COMPOUND GATE

IB

PROPOSED TELSTRA ACCESS TRACK (APPROX. 50m)

z

REFER TO SHEET 81-2 FOR ANTENNA LAYOUT

PROPOSED TELSTRA COMPOUND SECURITYFENCE WITH DOUBLE ACCESS GATES

PROPOSED TELSTRA LOW IMPACT ICS BS TYPE 1BEQUIPMENT SHELTER (3000 L x 2500 W x 2750 H)COLOURED PALE EUCALYPT ON CONCRETE PIERS

1>

PROPOSED TELSTRA STOCK FENCEAROUND GUY ANCHORS (TYP.)

PROPOSED TELSTRA GUY WIRES (TYP.)

PROPOSED TELSTRA GUY ANCHORFOOTING (SHOWN INDICATIVE ONLY)

SITE LAYOUTSCALE 1:1001m . 0lllllllinl

1mJ_

2m 3mJ_

4m_L 5m SCALE 1:100

GUY ANCHOR DETAILSSCALE 1:100

NOTE: THIS DRAWING TO BE READ IN CONJUNCTION WITH SHEETS S1 & S1-2

NOTES:PRELIMINARY

1. ALL EXTERNAL FEEDERS AND TAILS MUST BE BIRD PROOFED AS PEREXTERNAL PLANT POLICY 003615.2. ALL DIMENSIONS ARE IN MILLIMETRES UNLESS SPECIFIED OTHERWISE.3. THIS DRAWING SET IS A PRELIMINARY DRAWING ONLY AND IS ISSUED FORCOMMENT. IT IS NOT A DETAILED SURVEY / STRUCTURAL DRAWING ANDTHEREFORE COULD BE SUBJECT TO CHANGE.4. FOR EME SIGNS NOTED THUSgXJREFER TO 005486 FOR DETAILS.5. CLEAR ALL VEGETATION WITHIN THE COMPOUND TO MINIMISE SNAKEACTIVITY.

serviceMOBII E COMMONICAIIOHS

Level 3, 7-9 Tanunda Drive, Riven/ale WA 6103

T +61 8 9355 7500 I F +61 8 9355 5100 I www.servicestream.com.au

ORDERBL PRELIMINARY - 30064619W0230SSMC - WCDMA850 /LTE700 JK

APPD DATE24.11.17

(c)Telstra Corporation Limited ABN 33 051 775 556 All rights reserved.

^elstraMOBILE NETWORK SITE 316700

TENINDEWA(YUNAROAD)SITE LAYOUT

LOT 6061 JOHNSON ROAD, TENINDEWA, WA 6632

DWGNO. W108607 SHT 81-1

NO.

T 1 \/ T 1 |Cadfite:W108607.dwg 6 "A3The coDvriaht and oiwnershiD of the drawinas is to be assigned to Telstra

Page 5: together with cabling and ancillary equipment, including ... · The facility proposed by Telstra comprises a 60m guyed mast with a 3m extension, six (6) panel antennas ... together

D

DO NOTSCALE

^\

TN

t ANTENNA LEGENDPROPOSED TELSTRAPANEL ANTENNA

PROPOSED TELSTRA WCDMA850 / LTE700 COMBINERS(3 OFF) ATTACHED BEHIND PROPOSED PANELANTENNAS (A1, A3 & A5) ON PROPOSED MOUNTS

BEHIND PARABOLICANTENNA

-^

BEHIND EACHPANEL ANTENNA

A200&A201 (BELOW)

ANTENNA LAYOUT AT EL 59.4m & 55.0mSCALE 1:25

(T/P.I

ANTENNA LAYOUT AT EL 62.3mSCALE 1:25500. . . .0. .. .500

1111 Imnunl 11111

500 .. 01111 lnnnnil

.500J_ -i1000 SCALE 1:25

^mo SCALE 1:25

NOTE: THIS DRAWING TO BE READ IN CONJUNCTION WITH SHEETS 81 & 81-1

NOTES:

PROPOSED TELSTRA LTE700 / WCDMA850 TMA'S(3 OFF) ATTACHED BEHIND PROPOSED TELSTRAPANEL ANTENNAS (A1, A3 &A5)

PROPOSED TELSTRAWCDMA850 RRU'S(3 OFF) WITH WCDMA850 FILTERS (3 OFF)BELOW ON PROPOSED MOUNTS

PROPOSED TELSTRA TRIANGULAR HEADFRAME.REFER TO STD DRG 017866P182 FOR DETAILS

PROPOSED TELSTRA 60m HIGH WITH 3mEXTENSION 750 F/W GUYED MAST

PROPOSED TELSTRA LTE700 RRU'S (6 OFF)WITH RRU INTERFACE JUNCTION BOXES(3 OFF) ON PROPOSED MOUNTS

PROPOSED TELSTRA LTE700 PANEL ANTENNAS(3 OFF A2, A4 & A6) ON PROPOSED MOUNTS

PROPOSED TELSTRA LTE700 COMBINERS (3 OFF)ATTACHED BEHIND PROPOSED PANELANTENNAS (A2, A4 &A6) ON PROPOSED MOUNTS

PROPOSED TELSTRA WCDMA850 / LTE700PANEL ANTENNAS (3 OFF A1, A3 & A5) ONPROPOSED MOUNTS

PRELIMINARY1.ALL EXTERNAL FEEDERS AND TAILS MUST BE BIRD PROOFED AS PEREXTERNAL PLANT POLICY 003615.2. ALL DIMENSIONS ARE IN MILLIMETRES UNLESS SPECIFIED OTHERWISE.3. THIS DRAWING SET IS A PRELIMINARY DRAWING ONLY AND IS ISSUED FORCOMMENT. IT IS NOT A DETAILED SURVEY/ STRUCTURAL DRAWING ANDTHEREFORE COULD BE SUBJECT TO CHANGE.4. FOR EME SIGNS NOTED THUS j#X| REFER TO 005486 FOR DETAILS.5. CLEAR ALL VEGETATION WITHIN THE COMPOUND TO MINIMISE SNAKEACTIVITY.

serviceMORII F COMHUNiOVnOI'IS

Level 3, 7-9 Tanunda Drive. Rlvervale WA 6103

T +61 8 9355 7500 I F +61 8 9355 5100 | www.servicestream.com.au

ORDERid.01 BL

AMENDMENTPRELIMINARY - 30064619W0230SSMC - WCDMA850 /LTE700 JK

APPD DATE24.11.17

©Telstra Corporation Limited ABN 33 051 775 556 All rights reserved.

^elstraMOBILE NETWORK SITE 316700

TENINDEWA(YUNAROAD)ANTENNA LAYOUT

LOT 6061 JOHNSON ROAD, TENINDEWA, WA 6632

DWGNO. W108607 SHT

NO.S1-2

J_ 1. \z_ A. I Cad file: W108607.dwg l3_The coDvriaht and ownershiD of the drawinas is to be asstaned to Telstra

Page 6: together with cabling and ancillary equipment, including ... · The facility proposed by Telstra comprises a 60m guyed mast with a 3m extension, six (6) panel antennas ... together

B

D

DO NOTSCALE

I 3:PROPOSED OBSTACLE LIGHT

#2

'7V

BEHIND EACHPANEL ANTENNA

PROPOSED TELSTRA TRIANGULAR HEADFRAME.REFER TO STD DRG 017866P182 FOR DETAILS

PROPOSED TELSTRA LTE700 / WCDMA850 TMA'S(3 OFF) ATTACHED BEHIND PROPOSED TELSTRAPANEL ANTENNAS (A1, A3 & A5)

PROPOSED TELSTRA WCDMA850 / LTE700 COMBINERS(3 OFF) ATTACHED BEHIND PROPOSED PANELANTENNAS (A1, A3 &A5) ON PROPOSED MOUNTS

PROPOSED TELSTRA LTE700 COMBINERS (3 OFF) -ATTACHED BEHIND PROPOSED PANEL ANTENNAS(A2, A4 & A6) ON PROPOSED MOUNTS

SITE EME SIGNAGE

EMETELSTRA#2SIGNSIGNS TO BE UV STABLE STICKERSAND FIXED TO REAR OF ALLTELSTRA PANEL ANTENNAS (6 OFF)

#6 EMETELSTRA#6SIGNPROPOSED SIGN SECURED1.5m AGL TO MAST USINGSTAINLESS STEEL STRAPS

I #111 EMETELSTRA#11SIGNPROPOSED TO BE INSTALLED /BEHIND TELSTRA PROPOSED DISH

I #131 EMETELSTRA#13SIGNPROPOSED SIGN SECURED TOTELSTRA COMPOUND GATE USINGSTAINLESS STEEL STRAPS

PROPOSED TELSTRA 450W CABLE LADDER •TO ACCOMMODATE PROPOSED TELSTRAFEEDERS(5 OFF)

PROPOSED TELSTRA GPS ANTENNA(1 OFF A12) •MOUNTED ON PROPOSED ANTENNA BRACKETNEAR FEEDER WINDOW ON SHELTER ROOF

v E.L3.1m(±100mm) R.L 227.1m AHDBASE OF PROPOSED TELSTRAGPS ANTENNA (1 OFF AX)

PROPOSED TELSTRA LOW IMPACT ICS BS P^PE 1BEQUIPMENT SHELTER (3000 L x 2500 W x 2750 H)COLOURED PALE EUCALYPT ON CONCRETE PIERS

PROPOSED TELSTRA COMPOUND SECURITY •FENCE WITH DOUBLE ACCESS GATES

PROPOSED TELSTRA U/GSUBMAINS FROM PILLAR

PROPOSED TELSTRA MAST BASEFOOTING (SHOWN INDICATIVELY)

1516.

y E.L. 63.3m (±100mm)OVERALL HEIGHT

V E.L 62.8m (±100mm)C/L PROPOSED TELSTRA LTE700 RRU'S (6 OFF)

v E.L. 62.3m (±100mm)C/L PROPOSED TELSTRA WCDMA850 / LTE700PANEL ANTENNAS (3 OFF A1, A3 & A5)C/L PROPOSED TELSTRA LTE700 PANEL ANTENNAS (3 OFF A2, A4 & A6)TOP OF PROPOSED EXTENSION

y El.61.8m (±100mm)C/L PROPOSED TELSTRA WCDMA850 RRU'S (3 OFF)

V E.L 59.4m (±100mm)C/L PROPOSED TELSTRA RT DISH (1 OFF A200)TOP OF PROPOSED GUYED MAST

v E.L. 55.0m (±100mm)r-> C/L PROPOSED TELSTRA RT DISH (1 OFF A201)

BEHIND PARABOLICANTENNA

RESERVED LOCATION FOR WA ESQ EQUIPMENTS

PROPOSED TELSTRA 60m HIGH WITH3m EXTENSION 750 F/W GUYED MAST

PROPOSED TELSTRA FEEDER CABLES (5 OFF)

PROPOSED TELSTRA TORSIONAL STABILISE?(INDICATIVE ONLY)PROPOSED TELSTRA GUY WIRES CTYP.)

1.ALL EXTERNAL FEEDERS AND TAILS MUST BE BIRD PROOFED AS PEREXTERNAL PLANT POLICY 003615.2. ALL DIMENSIONS ARE IN MILLIMETRES UNLESS SPECIFIED OTHERWISE.3. THIS DRAWING SET IS A PRELIMINARY DRAWING ONLY AND IS ISSUED FORCOMMENT. IT IS NOT A DETAILED SURVEY / STRUCTURAL DRAWING ANDTHEREFORE COULD BE SUBJECT TO CHANGE.4. FOR EME SIGNS NOTED THUS |#X] REFER TO 005486 FOR DETAILS.5. FOUNDATIONS AND GUY WIRES ARE SHOWN INDICATIVE ONLY. FINALDESIGN IS SUBJECT TO RESULTS OF GEOTECHNICAL INVESTIGATION.

EAST ELEVATION2m 4m

I6m

I8m

I10m

SCALE 1:200

PROPOSED SIGN SECURED TOTELSTRA COMPOUND GATE

1.5mAGL

PROPOSED WESTERN POWER MINI PILLAR(SUBJECTED TO WP DESIGN)

PROPOSED WP U/G SUBMAINS ROUTE (APPROX. 90m) TBC

- PROPOSED TELSTRA STOCK FENCE\ / AROUND GUY ANCHORS (JVP.)

T— PROPOSED TELSTRA GUY ANCHORN J\ \ FOOTING (SHOWN INDICATIVE ONLY)

\ \

Tst

"T

-_-_-L

v E.L. 0.0m

GROUND LEVEL

NOTE: THIS DRAWING TO BE READ IN CONJUNCTION WITH SHEET S3-1 PRELIMINARY

A|

Bl

N

Dl

service:3'-'MUN'C^.";2NS

Level 3, 7-9 Tanunda Drive, Rlvervale WA 6103T +61 S 9355 7500 I F +61 8 9355 5100 | www.servicestream.com.au

ORDERMA

CHKDBL PRELIMINARY - 30064619W0230SSMC - WCDMA850 /LTE700

AMENDMENT EXAMJK

APPD DATE24.11.17

©Telstra Corporation Limited ABN 33 051 775 556 All rights reserved.

^elstraMOBILE NETWORK SITE 316700

TENINDEWA (YUNA ROAD)EAST ELEVATION

LOT 6061 JOHNSON ROAD, TENINDEWA, WA 6632

DWGNO. W108607 SHT S3

NO.