tmsc/cr n and speci - syi · 2016. 9. 14. · oshiba has the answer in the ime-100l. 2....
TRANSCRIPT
![Page 1: TMSC/CR n and speci - syi · 2016. 9. 14. · oshiba has the answer in the IME-100L. 2. Wheel-guided motion w vercome ! oor gradients with less manual force. Wheel step " is step](https://reader036.vdocuments.site/reader036/viewer/2022081403/60a17e1ac32daa75c55beed3/html5/thumbnails/1.jpg)
©Toshiba M
edical Systems Corporation 2000-2001. All rights reserved.
Design and specifications subject to change w
ithout notice.M
CAXR0100EAB 2001-03 TMSC/CR
http://www.toshibam
edicalsystems.com
Printed in Japan
Toshiba Medical System
s Corporation meets internationally recognized
standards for Quality M
anagement System
ISO 9001 ISO
13485.
Toshiba Medical System
s Corporation Nasu O
perations meets the
Environmental M
anagement System
standard ISO 14001.
![Page 2: TMSC/CR n and speci - syi · 2016. 9. 14. · oshiba has the answer in the IME-100L. 2. Wheel-guided motion w vercome ! oor gradients with less manual force. Wheel step " is step](https://reader036.vdocuments.site/reader036/viewer/2022081403/60a17e1ac32daa75c55beed3/html5/thumbnails/2.jpg)
3
—The new
standard for mobile X-ray system
s
Mobile X-ray system
s are moved around hospitals
all the time to perform
radiography on patients who
cannot easily get to an X-ray room.
What m
akes a system environm
ent-friendly and
easy-to-use?
To address these issues, Toshiba has kept the
basics in mind, w
hile advancing the development of
motor-driven, high-perform
ance systems.
Now, Toshiba has the answ
er in the IME-100L.
2
![Page 3: TMSC/CR n and speci - syi · 2016. 9. 14. · oshiba has the answer in the IME-100L. 2. Wheel-guided motion w vercome ! oor gradients with less manual force. Wheel step " is step](https://reader036.vdocuments.site/reader036/viewer/2022081403/60a17e1ac32daa75c55beed3/html5/thumbnails/3.jpg)
Wheel-guided m
otionLarge wheels and wheel-guided m
otion allow operators to overcom
e floor gradients with less m
anual force.
Wheel step
This step is easy to tread on, and has suffi
cientclearance above the floor. Th
e safety design eliminates
the risk of a foot being caught between the step and the floor, even in the wheel-guided setting.
Bumper
A bumper the sam
e width as the cart is provided at the front of the equipm
ent, to alleviate the shock caused by possible collisions.
Corner guideTh
is allows you to confirm the position of the
bumpers while the equipm
ent is in motion, and
helps in navigating narrow spaces.
Deadman-type brake
A deadman-type brake is em
ployed. If the handle is released, the brake will be applied autom
atically. A slight handle m
ovement causes deceleration while in
motion.
Brake elimination
You can choose a brake-free condition. Thus, you
can easily position the equipment while m
oving the m
ain assembly.
Vertical rotation of X-ray tubeTh
e X-ray tube can be rotated vertically by ±90º, and easily positioned for lateral-view radiography.
Swiveling of the X-ray tube
The X-ray tube assem
bly can be swiveled forward by –15º through +90º. H
andgrip manipulation
maintains the orientation of the X-ray port
irrespective of the height of the arm.
Large wheels
Large 40-cm diam
eter wheels are employed. Th
ese are com
bined with free-castor-type front wheels to ensure quietness and ease of m
ovement.
HandgripsTh
ese allow you to swivel and rotate the X-ray tube with less m
anual force.
Pantograph-type armA well-balanced, lock-free arm
is employed.
It eliminates tim
e-consuming arm
lock procedures for positioning, ensuring m
ore speedy positioning.
54
Horizontal rotation of armTh
e arm can be rotated horizontally around the
support column by ±45º. For bedside radiography, it
is unnecessary to change the orientation of the main
body of the equipment.
Flexible movem
ent ensures smooth exam
inations
![Page 4: TMSC/CR n and speci - syi · 2016. 9. 14. · oshiba has the answer in the IME-100L. 2. Wheel-guided motion w vercome ! oor gradients with less manual force. Wheel step " is step](https://reader036.vdocuments.site/reader036/viewer/2022081403/60a17e1ac32daa75c55beed3/html5/thumbnails/4.jpg)
CO
MPO
SITIO
NSPEC
IFICAT
ION
S
OPT
ION
AL ITEM
S
POW
ER R
EQU
IREM
ENT
S
MO
VEMEN
T RAN
GE
DIM
ENSIO
NS
X-ray generatorInverter (m
ax. 40 kHz, 18 kW
)40 kV to 125 kV in 2 kV steps0.5 m
As to 100 mAs in 24 steps
max. 300 m
A
TypekV rangem
As rangem
A rangeX-ray tube unit D
RX-1603B1.0 m
m16˚
Focal spotTarget angle
X-ray beam lim
iting device0 × 0 to 43 cm
× 43 cm (17" × 17")
at SID = 100 cm
(39.4")X-ray field size
Halogen
Projection lamp
Average illumination of not less than
160 lux at SID = 100 cm
(39.4")Light intensity
1.2 mm
Aleq(Total filration m
in. 2.5 mm
Aleq)Filtration
Movem
ent range of X-ray tube unit (center of X-ray tube unit)47 cm
to 205 cm (18.5" to 80.7")
from floor level to focus
Vertical
max. 115 cm
(45.3")from
column to focus
Horizontal
±90°
90° forward,15° backward±45°
Horizontal rotation of arm
Lateral pivoting ofX-ray tube unitLongitudinal pivotingof X-ray tube unit
Can store up to 8 cassettes35 cm
× 45 cm (14" × 17") cassettes
Cassette box
Single-phase, 100/110/115/120/127/220/240 VAC ±10%
Voltage
50/60 Hz
Frequency1.5 kVA
Capacity
0.5 ΩM
aximum
allowableline im
pedance
X-ray control unitH
igh-voltage generator
Power cableSet of high-voltage cablesM
obile cart and X-ray tube support unitX-ray beam
limiting device
X-ray tube unit DRX-1603B
Handswitch
111 1 1 1 11
Remoto exposure switch
RCIM-100L
Large cassette boxLCIM
-100L
7
X-ray beam lim
iting deviceIt incorporat es a high-brightness halogenlam
p with an SID m
easure, and can berotated by ±100˚.
Vertical-rotation arm lock
The arm
is provided with a lockingm
echanism which easily fixes the arm
.
Horizontal-rotation arm lock
The support colum
n is provided with alocking m
echanism. It suppresses vibration of
the arm while the equipm
ent is in motion,
and protects against failure.
X-ray control panelAll indicators, digital displays and sheet keysare arranged in a functional m
anner.
Single component panel
The upper part consists of a single plastic
component. Th
is safety design prevents spilledliquids from
entering the equipment.
Key switch
The key swich breaks the circuit for the safe
use and storage of the X-ray equipment.
Cassette boxIt can house up to 8, 35 cm
× 45 cm(14" × 17"), lightweight cassettes.
Power supply cable
This is a cord-reel-type 3 pin power supply
cable that can be easily accomm
odated.
Handswitch
The handswitch can work over 2 m
eters awayfrom
the equipment, ensuring reduced
radiation exposure for operators.
Large cassette box (option)It can house up to 10, 35 cm
× 45 cm(14" × 17"), lightweight cassettes.
Remote exposure sw
itch (option)Th
is is an infrared-type switch that permits
remote control of an irradiation field lam
p andX-ray exposure.
A wide range of utilities for ease of use