©Toshiba Medical Systems Corporation 2000-2001. All rights reserved. Design and specications subject to change without notice. MCAXR0100EAB 2001-03 TMSC/CR http://www.toshibamedicalsystems.com Printed in Japan Toshiba Medical Systems Corporation meets internationally recognized standards for Quality Management System ISO 9001 ISO 13485. Toshiba Medical Systems Corporation Nasu Operations meets the Environmental Management System standard ISO 14001.

Upload: others

Post on 18-Jan-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: TMSC/CR n and speci - syi · 2016. 9. 14. · oshiba has the answer in the IME-100L. 2. Wheel-guided motion w vercome ! oor gradients with less manual force. Wheel step " is step

©Toshiba M

edical Systems Corporation 2000-2001. All rights reserved.

Design and specifications subject to change w

ithout notice.M

CAXR0100EAB 2001-03 TMSC/CR

http://www.toshibam

edicalsystems.com

Printed in Japan

Toshiba Medical System

s Corporation meets internationally recognized

standards for Quality M

anagement System

ISO 9001 ISO

13485.

Toshiba Medical System

s Corporation Nasu O

perations meets the

Environmental M

anagement System

standard ISO 14001.

Page 2: TMSC/CR n and speci - syi · 2016. 9. 14. · oshiba has the answer in the IME-100L. 2. Wheel-guided motion w vercome ! oor gradients with less manual force. Wheel step " is step

3

—The new

standard for mobile X-ray system

s

Mobile X-ray system

s are moved around hospitals

all the time to perform

radiography on patients who

cannot easily get to an X-ray room.

What m

akes a system environm

ent-friendly and

easy-to-use?

To address these issues, Toshiba has kept the

basics in mind, w

hile advancing the development of

motor-driven, high-perform

ance systems.

Now, Toshiba has the answ

er in the IME-100L.

2

Page 3: TMSC/CR n and speci - syi · 2016. 9. 14. · oshiba has the answer in the IME-100L. 2. Wheel-guided motion w vercome ! oor gradients with less manual force. Wheel step " is step

Wheel-guided m

otionLarge wheels and wheel-guided m

otion allow operators to overcom

e floor gradients with less m

anual force.

Wheel step

This step is easy to tread on, and has suffi

cientclearance above the floor. Th

e safety design eliminates

the risk of a foot being caught between the step and the floor, even in the wheel-guided setting.

Bumper

A bumper the sam

e width as the cart is provided at the front of the equipm

ent, to alleviate the shock caused by possible collisions.

Corner guideTh

is allows you to confirm the position of the

bumpers while the equipm

ent is in motion, and

helps in navigating narrow spaces.

Deadman-type brake

A deadman-type brake is em

ployed. If the handle is released, the brake will be applied autom

atically. A slight handle m

ovement causes deceleration while in

motion.

Brake elimination

You can choose a brake-free condition. Thus, you

can easily position the equipment while m

oving the m

ain assembly.

Vertical rotation of X-ray tubeTh

e X-ray tube can be rotated vertically by ±90º, and easily positioned for lateral-view radiography.

Swiveling of the X-ray tube

The X-ray tube assem

bly can be swiveled forward by –15º through +90º. H

andgrip manipulation

maintains the orientation of the X-ray port

irrespective of the height of the arm.

Large wheels

Large 40-cm diam

eter wheels are employed. Th

ese are com

bined with free-castor-type front wheels to ensure quietness and ease of m

ovement.

HandgripsTh

ese allow you to swivel and rotate the X-ray tube with less m

anual force.

Pantograph-type armA well-balanced, lock-free arm

is employed.

It eliminates tim

e-consuming arm

lock procedures for positioning, ensuring m

ore speedy positioning.

54

Horizontal rotation of armTh

e arm can be rotated horizontally around the

support column by ±45º. For bedside radiography, it

is unnecessary to change the orientation of the main

body of the equipment.

Flexible movem

ent ensures smooth exam

inations

Page 4: TMSC/CR n and speci - syi · 2016. 9. 14. · oshiba has the answer in the IME-100L. 2. Wheel-guided motion w vercome ! oor gradients with less manual force. Wheel step " is step

CO

MPO

SITIO

NSPEC

IFICAT

ION

S

OPT

ION

AL ITEM

S

POW

ER R

EQU

IREM

ENT

S

MO

VEMEN

T RAN

GE

DIM

ENSIO

NS

X-ray generatorInverter (m

ax. 40 kHz, 18 kW

)40 kV to 125 kV in 2 kV steps0.5 m

As to 100 mAs in 24 steps

max. 300 m

A

TypekV rangem

As rangem

A rangeX-ray tube unit D

RX-1603B1.0 m

m16˚

Focal spotTarget angle

X-ray beam lim

iting device0 × 0 to 43 cm

× 43 cm (17" × 17")

at SID = 100 cm

(39.4")X-ray field size

Halogen

Projection lamp

Average illumination of not less than

160 lux at SID = 100 cm

(39.4")Light intensity

1.2 mm

Aleq(Total filration m

in. 2.5 mm

Aleq)Filtration

Movem

ent range of X-ray tube unit (center of X-ray tube unit)47 cm

to 205 cm (18.5" to 80.7")

from floor level to focus

Vertical

max. 115 cm

(45.3")from

column to focus

Horizontal

±90°

90° forward,15° backward±45°

Horizontal rotation of arm

Lateral pivoting ofX-ray tube unitLongitudinal pivotingof X-ray tube unit

Can store up to 8 cassettes35 cm

× 45 cm (14" × 17") cassettes

Cassette box

Single-phase, 100/110/115/120/127/220/240 VAC ±10%

Voltage

50/60 Hz

Frequency1.5 kVA

Capacity

0.5 ΩM

aximum

allowableline im

pedance

X-ray control unitH

igh-voltage generator

Power cableSet of high-voltage cablesM

obile cart and X-ray tube support unitX-ray beam

limiting device

X-ray tube unit DRX-1603B

Handswitch

111 1 1 1 11

Remoto exposure switch

RCIM-100L

Large cassette boxLCIM

-100L

7

X-ray beam lim

iting deviceIt incorporat es a high-brightness halogenlam

p with an SID m

easure, and can berotated by ±100˚.

Vertical-rotation arm lock

The arm

is provided with a lockingm

echanism which easily fixes the arm

.

Horizontal-rotation arm lock

The support colum

n is provided with alocking m

echanism. It suppresses vibration of

the arm while the equipm

ent is in motion,

and protects against failure.

X-ray control panelAll indicators, digital displays and sheet keysare arranged in a functional m

anner.

Single component panel

The upper part consists of a single plastic

component. Th

is safety design prevents spilledliquids from

entering the equipment.

Key switch

The key swich breaks the circuit for the safe

use and storage of the X-ray equipment.

Cassette boxIt can house up to 8, 35 cm

× 45 cm(14" × 17"), lightweight cassettes.

Power supply cable

This is a cord-reel-type 3 pin power supply

cable that can be easily accomm

odated.

Handswitch

The handswitch can work over 2 m

eters awayfrom

the equipment, ensuring reduced

radiation exposure for operators.

Large cassette box (option)It can house up to 10, 35 cm

× 45 cm(14" × 17"), lightweight cassettes.

Remote exposure sw

itch (option)Th

is is an infrared-type switch that permits

remote control of an irradiation field lam

p andX-ray exposure.

A wide range of utilities for ease of use

6