tizian cad/cam system (3.5 ax) (pm 15)

8
Tizian CAD/CAM Zirconium dioxide without limits TM Schütz Dental GmbH • Dieselstr. 5-6 • 61191 Rosbach /Germany • Tel.: +49 (0) 6003 814-365 • Fax: +49 (0) 6003 814-907 www.schuetz-dental.de • [email protected]

Upload: lam-dao

Post on 23-Mar-2016

217 views

Category:

Documents


3 download

DESCRIPTION

The Tizian CAD/CAM System Specs: - 3.5 axis - accuracy: +/- 15 micrometre - applications as: prostheses & Implant abutments

TRANSCRIPT

Page 1: Tizian CAD/CAM System (3.5 ax) (pm 15)

Tizian CAD/CAM

Zirconium dioxidewithout limits

TM

Schütz Dental GmbH • Dieselstr. 5-6 • 61191 Rosbach /Germany • Tel.: +49 (0) 6003 814-365 • Fax: +49 (0) 6003 814-907 www.schuetz-dental.de • [email protected]

Page 2: Tizian CAD/CAM System (3.5 ax) (pm 15)

It is not just its technology which makes this 3D-optical scanner an attractive option, but also its design and ease of use.

Features:Application: Individual stumps, bridges up to 16 units, abutment supra constructions, counter jaw, occlusal position, gingiva, wax-up.

• Open data interface, not exclusive to any particularCAD/CAM software or finishing process

• Data generated in universal STL format• Scan time for a single stump < 2 min.

for a complete jaw < 10 min.for a 3-unit bridge < 3 min.

• 3.5 axes for detailed and exact scan results• High depth of focus • automatic completion of smaller blank areas

in the scan• rescan function for larger blank areas

(no completely new scan necessary)

Tizian™ Scan

barcode- and dongle-free, open STL-files

• Precision: better than ± 15 µm• High accuracy of fit • The sensor captures complicated bridge situations

and stump geometries exactly without gaps or blind spots

• Preparation margin is detected precisely• Easy to use software applications• No scan gipsum hecessary

Tizian™ CAD/CAMTechnology means: Computer-aided scanning with Tizian™Scan,constructing with Tizian™Creativ RT design softwareand milling of zirconium dioxide blanks with Tizian™Cut

Tizian™CAD/CAM is economical and very user-friendly:

• Create added value for your lab with relatively low investment.• All components are perfectly designed to complement one another.• Easy to learn with basic computer knowledge.• Wide range of materials: clear acrylic (for casting), zirconium dioxide,

tooth-colored acrylic (for temporary constructions)• Open STL-files: You are free to send your pre-modelled case to a milling center,

whose software / hardware is compatible to our system

Page 3: Tizian CAD/CAM System (3.5 ax) (pm 15)

Scanning is a simple process. Once the order withthe customer’s data has been created, the saw-cutmodel is set into the holder, an overview scan is carried out and the individual stumps are scanned in detail. The model is immediately displayed on thescreen. Our CAD-program offers you multiple designpossibilities. Offset copings, anatomic crowns andbridges, telescoping and conic crowns, inlays,onlays, veneers and more, are all easily designedwith a system that runs almost independantly.

Intuitive menu management:In just a few easy steps you can create perfect restorations on screen. The program will lead youthrough the menus step by step. The learning curveis very short, thanks to the easy menu arrangement.All important parameters are individually adjustable;for example, diameter of the connectors, the strengthof the walls or the thickness of the cement gap.

Features:

• Modellation in real time• Subsequent finishing• Automatic adaption to counter jaw and gingiva• Individually editable pontic and tooth archives

Tizian™ Creativ RTLeaves nothing to be desired

09 Margin des

02 Determine

01 Workflow: Creating a patient file

Production of a bridge with several units

10 Bite registraadjustment

02 Determine

01 Workflow: Creating a patient file

Production of primary telescopes

01 Scanned model 02 Finding the

Production of an inlay

Page 4: Tizian CAD/CAM System (3.5 ax) (pm 15)

ign

bite registration

10 Bite registration for adjustment of occlusion

03 3D scan

11 Wax knife for finishing

04 After scan

12 Reduction

05 Finding the prep margin

13 Positioning of the bridge units

06 Finishing the pre

ation for of occlusion

bite registration

11 Wax knife for finishing

03 3D scan

12 Reduction

04 After scan

13 Positioning of the bridge units

05 Finding the prep margin

14 Finishing of reduelements

06 Finishing the pre

prep margin 03 Finished prep margin 04 Generating the cement gap 05 Placing the inlay crown 06 Wax knife for fin

Page 5: Tizian CAD/CAM System (3.5 ax) (pm 15)

ep margin

14 Finishing of reduced elements

07 Einschubeditor

15 Design of connectors

08 Generating the cement gap

16 Finished bridge

uced

ep margin

15 Design of connectors

07 Einschubeditor

16 Individualization of the telescopes

08 Generating the cement gap 09 Margin design

17 Finished telescopes

08 Finished inlayishing 07 Reduced anatomy

18 Possibility to subsequ

Page 6: Tizian CAD/CAM System (3.5 ax) (pm 15)

uent finishing

Funktionen:

Basic software package:• Automatic location of the prep margin• Individual, three-dimensional adjustment of the crown margin• Offset copings• Reduced anatomic crowns and bridges• Fully anatomic crowns and bridges• Crowns and bridges on abutment suprastructions• Hybrid abutments• Free gingiva adaption for modellation of the emergence profile• Telescopic and conic crowns• Anatomic inlays, onlays, and veneers• Inlay shells, inlay bridges, Maryland bridges• Uploading 3D objects (wax-up scans), reduceable• Inclusion of the scannend counter jaw• One-step overpressing modellation for crowns and bridges• Individually editable pontic and tooth archives• Gingiva margin can be designed freely and in reference to the connectors• Diversity of materials: zirconium dioxide, acrylic, metal (milling center)• Optimization of data sets for laser melting• Basic parameters can be saved differently for each user• Real time modellation • Statistic adjustment of occlusion to the counter jaw, while keeping the tooth

shape respectively with the cut-back method• Designing contact points towards neighboring teeth, while keeping the tooth

shape respectively with the cut-back method

Optional features:• Virtual articulator (to be available soon)

• Dynamic occlusion adjustment by means of an average value articulator• Abutment design (to be available soon)

Tools for manual finishing:• Anatomic forming of defined areas• Virtual wax knife (editable, available in different knife shapes):

applying, reducing, smoothing• Measuring /displaying material thickness, distances, penetrations• Individual lighting of different work areas on screen• All tools can be selected at any time during each step of the workflow

All tools and options can be selected at any time during the workflow. All parameters can be changed at any time, without loss of the complete data set.

The software facilitates access to the complete data set during and after the job, thus making corrections easy.

Page 7: Tizian CAD/CAM System (3.5 ax) (pm 15)

Tizian™ CutMilling at the touch of a buttonSimply secure the blanks by hand and you are ready to mill.

• Easy to handle because of very structured user guidance• Material data is entered manually for ideal results• Saves material by means of different positioning aids• Mills bridges of up to 16 units• 10 different blank sizes with appropriate receptacles• Fivefold tool changer with automatic length measurement• Short milling times (13-15 min/unit)• Compact tabletop unit

Page 8: Tizian CAD/CAM System (3.5 ax) (pm 15)

Schütz Dental GmbH • Dieselstr. 5-6 • 61191 Rosbach /Germany • Tel.: +49 (0) 6003 814-365 • Fax: +49 (0) 6003 814-907 www.schuetz-dental.de • [email protected]

Man

dler

02

/201

0

Tizian™ Scan

Technical data

Technical data of the scannerDimensions: 650 mm x 420 mm x 420 mmWeight: 40 kgInput supply voltage: 110-240 V AC, 50-60 HzAccreditation: CEOperational noise: < 70 dB3D-stripe light scannerScan area: 100 mm diameter x 30 mmModel colour: White aluminium (RAL9006)Scan time for a single stump < 2 min.Scan time for a complete jaw < 10 min.Scan time for a three-part bridge < 3 min.Precision: more exact than ± 15 µm

Tizian™ CutDimensions: 530 mm x 620 mm x 530 mmJäger high frequency spindle up to 60 000 U/minMilling times: (13-15 min/unit)Accommodates 12 blank sizes, 16 and 20 mm height2 precision mills5-fold tool changer3-axis engine plus one axis of rotation

Scope of delivery3D-Scanner Tizian™Scan including flexible model holder, connection cable loom, software CD with installation program, on-site training, also including PC with pre-installed software. Netviewer and FTPServer, for onlinesupport.