this site - philippine national police · provisions of the latest approved philippine electrical...

13
PD's QUARTERS CHAPEL ENTRANCE GATE MOTOR POOL OUTPOST FLAG POLE SECURITY OUTPOST SECURITY PARADE GROUND GRANDSTAND PPSC BUILDING RANGE FIRING PCLO PIAS BPO BUILDING COVERED BASKETBALL COURT PNCO FUTURE FUTURE ON-BASE HOUSING FUTURE ON-BASE HOUSING EXPANSION FUTURE CONCESSIONAIRE & OTHER FACILITIES N S E W GATE 2 OUTPOST SECURITY PARKING AREA PARKING AREA PARKING AREA PARKING PARKING BARRACKS WATER RESERVOIR LOCATION MAP SCALE 1:1000M E X I S T I N G R O A D SHEET NO. SUBMITTED BY: APPROVED BY: RECOMMEND APPROVAL: CHECKED BY: PREPARED BY: PROJECT TITLE: LOCATION: LOCATION: Republic of the Philippines NATIONAL POLICE COMMISSION PHILIPPINE NATIONAL POLICE Camp Quintin M Merecido, Davao City Kidalapong, Malita, Davao Occidental PROPOSED FIRING RANGE ENGINEERING SERVICE REGIONAL PROJECT MANAGEMENT UNIT 11 Director, ES Police Chief Superintendent PHILIP LAWRENCE S ABAPO, III POLICE SENIOR INSPECTOR ANTONIO A TAYLAN, JR Asst. Chief, RPMU MARIA DEOVINA G SEVILLANO Police Chief Inspector Acting Chief, RPMU ABELARDO C MATILLANO Police Senior Superintendent Chief of Staff, ES MANUEL G FABROS Police Senior Superintendent Deputy Director, ES DAVAO OCCIDENTAL POLICE PROVINCIAL OFFICE Acting Chief, ID, ES HONORIO R AGNILA Police Superintendent A-1 THIS SITE PERSPECTIVE VIEW No. 1 SCALE NTS

Upload: vuonglien

Post on 08-Sep-2018

225 views

Category:

Documents


0 download

TRANSCRIPT

PD's

QUARTERS CHAPELENTRANCE

GATE

MOTOR

POOL

OUTPOST

FLAG POLE

SECURITY

OUTPOSTSECURITY

PARADE GROUND

GRANDSTAND

PPSC

BUILDING

RANGEFIRING

PCLO

PIAS

BPO

BUILDING

COVERED

BASKETBALL

COURT

PNCO

FUTURE

FUTURE

ON-BASE

HOUSING

FUTURE

ON-BASE

HOUSING

EXPANSION

FUTURE CONCESSIONAIRE

& OTHER FACILITIES

N

S

EW

GATE 2OUTPOSTSECURITY

PARKING

AREAPARKING

AREA

PARKING

AREAPARKING

PARKING

BARRACKS

WATER

RESERVOIR

LOCATION MAPSCALE 1:1000M

E X I S T I N G R O A D

SHEET NO.SUBMITTED BY: APPROVED BY:RECOMMEND APPROVAL:CHECKED BY:PREPARED BY:PROJECT TITLE:

LOCATION: LOCATION:

Republic of the PhilippinesNATIONAL POLICE COMMISSIONPHILIPPINE NATIONAL POLICE

Camp Quintin M Merecido, Davao City

Kidalapong, Malita, Davao Occidental

PROPOSED FIRING RANGE

ENGINEERING SERVICE

REGIONAL PROJECT MANAGEMENT UNIT 11

Director, ES

Police Chief SuperintendentPHILIP LAWRENCE S ABAPO, IIIPOLICE SENIOR INSPECTOR

ANTONIO A TAYLAN, JR

Asst. Chief, RPMU

MARIA DEOVINA G SEVILLANOPolice Chief Inspector

Acting Chief, RPMU

ABELARDO C MATILLANOPolice Senior Superintendent

Chief of Staff, ES

MANUEL G FABROSPolice Senior Superintendent

Deputy Director, ES

DAVAO OCCIDENTAL POLICE PROVINCIAL OFFICE

Acting Chief, ID, ES

HONORIO R AGNILAPolice Superintendent

A-1

THIS SITE

PERSPECTIVE VIEW No. 1SCALE NTS

C:\Users\RUS-CRD\Desktop\JAVA FILES\JV FILES '14\FIRING RANGE\PERSPECTIVE FINAL\CPO\CPO FIRING RANGE ARIAL VIEW REAR.jpg

SHEET NO.SUBMITTED BY: APPROVED BY:RECOMMEND APPROVAL:CHECKED BY:PREPARED BY:PROJECT TITLE:

LOCATION: LOCATION:

Republic of the PhilippinesNATIONAL POLICE COMMISSIONPHILIPPINE NATIONAL POLICE

Camp Quintin M Merecido, Davao City

Kidalapong, Malita, Davao Occidental

PROPOSED FIRING RANGE

ENGINEERING SERVICE

REGIONAL PROJECT MANAGEMENT UNIT 11

Director, ES

Police Chief SuperintendentPHILIP LAWRENCE S ABAPO, IIIPOLICE SENIOR INSPECTOR

ANTONIO A TAYLAN, JR

Asst. Chief, RPMU

MARIA DEOVINA G SEVILLANOPolice Chief Inspector

Acting Chief, RPMU

ABELARDO C MATILLANOPolice Senior Superintendent

Chief of Staff, ES

MANUEL G FABROSPolice Senior Superintendent

Deputy Director, ES

DAVAO OCCIDENTAL POLICE PROVINCIAL OFFICE

Acting Chief, ID, ES

HONORIO R AGNILAPolice Superintendent

A-2

PERSPECTIVE VIEW No. 2SCALE NTS

PERSPECTIVE VIEW No. 3SCALE NTS

ROOFLINE ABOVE

BAY 1 BAY 2 BAY 3 BAY 4 BAY 5

BULLET TRAP

D O W N R A N G E

B A C K S T O PSAND TRAP

P I S T O L F I R I N G R A N G E

BULLET TRAPBULLET TRAP

UPPER ROOF

@ 4.5O M. HIGH

LOWER ROOF

@ 3.5O M. HIGH

M CR F CR

UT

ILIT

Y

ROOFLINE ABOVE

BU

LLE

TIN

BO

AR

D

BAY 1 BAY 2 BAY 3 BAY 4 BAY 5

RECEIVING

OFFICE ARMORY

STORAGERANGE

OFFICERLECTURE

ROOM

SNACK

BAR

BULLET TRAP

D O W N R A N G E

SHOOTERS AREA

BENCHESBENCHES

SHOOTERS LOUNGE AREA

B A C K S T O PSAND TRAP

P I S T O L F I R I N G R A N G E

FLOOR PLAN1SCALE 1:150MTS

1 SEE BACKSTOP DETAIL

ALUM FRAMED CLEAR GLASS ALUM FRAMED CLEAR GLASS

BULLET TRAPBULLET TRAP

B-B

E

2

1

3

4

5

6

7

8

CBA D

B-B

E

2

1

3

4

5

6

7

8

CBA D

ROOF PLAN1SCALE 1:150MTS

A-AA-A

SHEET NO.SUBMITTED BY: APPROVED BY:RECOMMEND APPROVAL:CHECKED BY:PREPARED BY:PROJECT TITLE:

LOCATION: LOCATION:

Republic of the PhilippinesNATIONAL POLICE COMMISSIONPHILIPPINE NATIONAL POLICE

Camp Quintin M Merecido, Davao City

Kidalapong, Malita, Davao Occidental

PROPOSED FIRING RANGE

ENGINEERING SERVICE

REGIONAL PROJECT MANAGEMENT UNIT 11

Director, ES

Police Chief SuperintendentPHILIP LAWRENCE S ABAPO, IIIPOLICE SENIOR INSPECTOR

ANTONIO A TAYLAN, JR

Asst. Chief, RPMU

MARIA DEOVINA G SEVILLANOPolice Chief Inspector

Acting Chief, RPMU

ABELARDO C MATILLANOPolice Senior Superintendent

Chief of Staff, ES

MANUEL G FABROSPolice Senior Superintendent

Deputy Director, ES

DAVAO OCCIDENTAL POLICE PROVINCIAL OFFICE

Acting Chief, ID, ES

HONORIO R AGNILAPolice Superintendent

A-3

ECBA D

SECTION THRU "A-A"1SCALE 1:100MTS

5 6 7 84321

RANGE

OFFICER RECEIVING

SHOOTERS

LOUNGE

AREA OFFICESHOOTERS

AREA

TOP OF LOWER ROOF BEAM

TOP OF UPPER ROOF BEAM

TOP OF LOWER ROOF GIRTTOP OF UPPER ROOF BEAM

TOP OF LOWER ROOF GIRT

TOP OF UPPER ROOF GIRT

SECTION THRU "B-B"1SCALE 1:100MTS

SHOOTERS LOUNGE AREA

TOP OF UPPER ROOF BEAM

TOP OF LOWER ROOF GIRT

TOP OF UPPER ROOF BEAM

SHEET NO.SUBMITTED BY: APPROVED BY:RECOMMEND APPROVAL:CHECKED BY:PREPARED BY:PROJECT TITLE:

LOCATION: LOCATION:

Republic of the PhilippinesNATIONAL POLICE COMMISSIONPHILIPPINE NATIONAL POLICE

Camp Quintin M Merecido, Davao City

Kidalapong, Malita, Davao Occidental

PROPOSED FIRING RANGE

ENGINEERING SERVICE

REGIONAL PROJECT MANAGEMENT UNIT 11

Director, ES

Police Chief SuperintendentPHILIP LAWRENCE S ABAPO, IIIPOLICE SENIOR INSPECTOR

ANTONIO A TAYLAN, JR

Asst. Chief, RPMU

MARIA DEOVINA G SEVILLANOPolice Chief Inspector

Acting Chief, RPMU

ABELARDO C MATILLANOPolice Senior Superintendent

Chief of Staff, ES

MANUEL G FABROSPolice Senior Superintendent

Deputy Director, ES

DAVAO OCCIDENTAL POLICE PROVINCIAL OFFICE

Acting Chief, ID, ES

HONORIO R AGNILAPolice Superintendent

A-5

LEFT SIDE ELEVATION1SCALE 1:100MTS

5 6 7 84

FIREWALL

321 ECBA D

FRONT ELEVATION1SCALE 1:100MTS

5678 4

FIREWALL

RIGHT SIDE ELEVATION1SCALE 1:100MTS

3 2 1 ECBA D

REAR ELEVATION1SCALE 1:100MTS

FIREWALL

TOP OF UPPER ROOF BEAM

TOP OF LOWER ROOF GIRT

TOP OF UPPER ROOF GIRT

TOP OF LOWER ROOF BEAM

TOP OF UPPER ROOF BEAM

TOP OF LOWER ROOF GIRT

TOP OF LOWER ROOF BEAM

TOP OF UPPER ROOF BEAM

TOP OF LOWER ROOF GIRTTOP OF UPPER ROOF BEAM

TOP OF LOWER ROOF GIRT

TOP OF UPPER ROOF GIRT

SHEET NO.SUBMITTED BY: APPROVED BY:RECOMMEND APPROVAL:CHECKED BY:PREPARED BY:PROJECT TITLE:

LOCATION: LOCATION:

Republic of the PhilippinesNATIONAL POLICE COMMISSIONPHILIPPINE NATIONAL POLICE

Camp Quintin M Merecido, Davao City

Kidalapong, Malita, Davao Occidental

PROPOSED FIRING RANGE

ENGINEERING SERVICE

REGIONAL PROJECT MANAGEMENT UNIT 11

Director, ES

Police Chief SuperintendentPHILIP LAWRENCE S ABAPO, IIIPOLICE SENIOR INSPECTOR

ANTONIO A TAYLAN, JR

Asst. Chief, RPMU

MARIA DEOVINA G SEVILLANOPolice Chief Inspector

Acting Chief, RPMU

ABELARDO C MATILLANOPolice Senior Superintendent

Chief of Staff, ES

MANUEL G FABROSPolice Senior Superintendent

Deputy Director, ES

DAVAO OCCIDENTAL POLICE PROVINCIAL OFFICE

Acting Chief, ID, ES

HONORIO R AGNILAPolice Superintendent

A-4

PROFESSIONAL ELECTRICAL ENGINEER

REG NO: PTR NO: TIN:

ISS. AT: ISS. ON: TEL:

NOTE: Sign and Seal of Electrical plans is the sole authority of a PROFESSIONAL ELECTRICAL

ENGINEER

R.A. 7920 Section 31, 32 & 34. Field of Practice and Prohibition in the Practice of Electrical

Engineering and preparation of plans, supervision of installation, application of the Philippine

Electrical Code.

It shall be unlawful for any person not authorized under this Act to prepare plans,

electrical valuations or specifications for any electrical wiring, equipment or system; and no

installation thereof shall be undertaken unless the plans, designs, valuations and specifications

have been prepared by or under the responsible charge of, and signed and sealed by a

professional electrical engineer; and the construction permit for the execution thereof is first

secured; and unless the work is done in accordance with the Philippine Electrical Code and is

executed under the responsible charge or supervision of a PROFESSIONAL ELECTRICAL

ENGINEER or REGISTERED ELECTRICAL ENGINEER or Registered Master Electrician, as the

case may be, and the routinary fiscal and ministerial requirements of the government agency, if

any, exercising jurisdiction over the particular installation have been complied with.

GENERAL NOTES:

ALL ELECTRICAL WORKS HEREIN SHALL BE DONE IN ACCORDANCE WITH THE NATIONAL BUILDING CODE,

PROVISIONS OF THE LATEST APPROVED PHILIPPINE ELECTRICAL CODE, THE LAWS AND ORDINANCES OF

THE LOCAL CODE ENFORCING AUTHORITIES AND REQUIREMENTS OF THE LOCAL ELECTRIC, TELEPHONE

COMPANY AND BUILDING ADMINISTRATION REQUIREMENTS.

ALL WORKS SHALL BE DONE UNDER THE DIRECT SUPERVISION OF LICENSE DULY REGISTERED

ELECTRICAL ENGINEER OR REGISTERED MASTER ELECTRICIAN.

1. CONTRACTOR SHALL SECURE ALL WIRING PERMIT AND ALL FEES REQUIRED FOR THE WORKS AND

FURNISH THE OWNER THE CERTIFICATE OF FINAL ELECTRICAL INSPECTION,

2. CONTRACTOR SHALL CONDUCT EARTH GROUND TEST, WIRE INSULATION AND LOAD TEST UPON

COMPLETION OF WORKS,

3. INCASE OF DISCREPANCY BETWEEN PLANS AND SITE CONDITION, SPECIFICATIONS & REVISIONS

CHANGES, THE CONTRACTOR SHOULD IMMEDIATELY VERIFY & CONSULT TOWITH THE

OFFICER-IN-CHARGE OF THE CONSTRUCTION (OICC) OF THE PNP ENGINEERING SERVICE (PNPES),

4. ALL LOCATION & MOUNTING HEIGHT ARE SUBJECT TO APPROVAL OF THE OICC OF PNPES,

5. CONTRACTOR SHALL BE RESPONSIBLE IN THE PREPARATION OF AS-BUILT PLANS DULY SIGNED

AND SEALED BY PROFESSIONAL ELECTRICAL ENGINEER, AND ELECTRONIC AUTOCAD FILES,

6. FINAL LIGHTING FIXTURES AND WIRING DEVICES SHALL BE APPROVED BY PNPES,

OICCREPRESENTATIVEENGINEER,

7. CONTRACTOR SHALL BE RESPONSIBLE FOR PREPARATION OF SHOP OR CONSTRUCTION DRAWING

REQUIRED BY OICCOWNERARCHITECHENGINEER, THIS INCLUDES DEVICES AND FIXTURES

ELEVATION,

8. CONTRACTOR SHALL VISIT SITE CONDITION AND INCLUDE ALL COST NECESSARY TO COMPLETE

THE SYSTEM AT NO COST TO OWNER, INCLUDING COST OF CORING SERVICE AND EXPENSES FOR

THE RESTORATION OF ANY DAMAGE AFFECTED CIVIL STRUCTUTAL ARCHITECTURAL FINISHES OR

RELOCATION OF EXISTING FACILITIES ON BUILDING,

9. CONTRACTOR SHALL LOCATE ALL SPLICING BOXES TO ACCESSIBLE PLACE OR WITH ACCESS

PANELS,

10. NOMINATED CONTRACTOR TO VERIFY ALL EQUIPMENTS TO BE INSTALLED OR PLACE WITHIN THE

BUILDING SITE, AND MAKE AN ADJUSTMENT WITH THE PNPES OICCENGINEER ARCHITECT

CONSENT,

11. THIS DRAWINGS ARE DIAGRAMATIC LAYOUT ONLY, ANY MATERIALS AND FITTINGS NOT SHOWN ON

THIS PLANS BUT NEEDED TO COMPLETE THE SYSTEM AND OPERATION SHALL BE INCLUDED WITH

THE CONTRACTOR'S SCOPE OF WORKS.

12. ADDITIONAL NOTES:

· USE OF MICA SHALL BE LIMITED TO 150mm MAXIMUM· USE OF FLEXIBLE METALLIC & NON METALLIC CONDUTIT SHALL BE LIMITED TO 1m MAXIMUM· PROVIDE PROPER CONDUIT SUPPORT, G.I. WIRES AS SUPPORT SHALL NOT BE ALLOWED· PROVIDE DOUBLE COAT OF RUST PROTECTIVE PAINT (RED OXIDE PRIMER) ON HANGERS AND

SUPPORTS.

SPECIFICATIONS:1. POWER SUPPLY TO THE BUILDING SHALL BE 230V, SINGLE PHASE,

2-WIRES, 60HZ.

2. ALL MATERIALS TO BE USED SHALL BE NEW AND APPROVED TYPE FOR

PURPOSE & LOCATION.

3. NORMAL AND EMERGENCY CIRCUIT SHALL NOT BE COMBINED IN ONE

RACEWAY OR CONDUIT.

4. RECEPTACLES FOR GENERAL USE SHALL BE DUPLEX 16A, 250VAC,

GROUND TYPE.

5. ALL WIRES SHOULD HAVE A MAXIMUM LOAD OF 80 OF WIRE AMPACITY.

6. LIGHT SWITCHES MINIMUM RATING SHALL BE 16A 230VAC.

7. ALL MATERIALS TO BE USED SHALL BE BRAND NEW AND SHALL HAVE THE

"P.S." MARKS.

8. MOUNTING HEIGHTS SHALL BE AS FOLLOWS:

A. LIGHT SWITCHES - 1.37m above Floor finish

B. CONVENIENCE OUTLET - 0.3m above Floor finish

C. TELEPHONE OUTLET - 0.3m above Floor finish

D. PANEL BOARD - 1.8m ABOVE FLOOR FINISH

9. CONDUIT EMBEDED WITHIN CONCRETE WALL SHALL HAVE A MINIMUM

CEMENT PLASTERED OF 20mm THICK.

10. ALL CONDUIT PIPE ABOVE CEILING SHOULD HAVE INDEPENDENT

HANGER SUPPORTS.

11. ALL LIGHTING FIXTURES SHOULD HAVE INDEPENDENT HANGER

SUPPORTS.

12. ALL BOXES SHALL BE OCCUPIED ONLY OF 50 OF WIRE VOLUME.

13. VOLTAGE DROP SHALL BE LIMITED TO 2.5 FROM SOURCE TO PANEL

BOARD AS P.E.C. REQUIREMENT OR ACCEPTABLE TO THE LABORATORY

EQUIPMENT.

14. CIRCUIT BREAKERS SERVING MOTORS AND LIGHTING SHALL BE

INDUSTRIAL AND COMMERCIAL BOLT-ON TYPE RESPECTIVELY WITH

MINIMUM OF 6kAIC.

15. ALL WIRES AND CABLES SHALL BE BRAND NEW AND APPROVED TYPE.

16. USE SOLDERLESS CONNECTOR, MECHANICAL 1 PRESSURE TYPE COPPER

LUGS FOR CONNECTION OF WIRES LARGER THAN 8mm².

17. USE FILLER COMPOUND, "SCOTCH FILL" OR APPROVED EQUAL AT SHARP

EDGES TO PROVIDE SMOOTH SURFACE BEFORE TAPING WITH

ELECTRICAL TAPE.

LED EMERGENCY LIGHT

9W LED DOWNLIGHT

1-GANG OF 3-SINGLE POLE SWITCHESSabc

DP1 DP1-DISTRIBUTION PANEL 1

LEGEND & SYMBOLS

DUPLEX CONVENIENCE OUTLET WITH GROUND

CIRCUIT HOMERUN, A-ACU CIRCUIT HOMERUN,

L-LIGHTING CIRCUIT HOMERUN, C-CONVENIENCE

OUTLET CIRCUIT HOMERUN

1 x 18 LED TUBE, BOX TYPE

1-GANG OF 2-SINGLE POLE SWITCHESSab

2-WIRE SERVICE ENTRANCE

SWITCH CONDUIT RUN

LIGHTING CIRCUIT CONDUIT RUN

RECEPTACLE OUTLET CIRCUIT CONDUIT RUN

225 AT3PCIRCUIT BREAKER

11 x 18 LED TUBE, WITH WEATHER PROOF CASING

50W LED FLOOD LIGHT

TABLE OF CONTENTS

SHEET

NOSHEET CONTENTS

DRAWING

NO

E1 GENERAL NOTES & SPECIFICATIONS 1

LEGEND & SYMBOLS 2

LOCATION & SITE DEVELOPMENT PLAN 3

ORBIT FAN

CEILING MOUNTED EXHAUST FAN

OUTPOSTSECURITY

OUTPOSTSECURITY

PPSC

BUILDING

RANGEFIRING

COVERED

BASKETBALL

COURT

BARRACKS

FUTURE

ON-BASE

HOUSING

T-350kVA

L2, P7

P6

2 - 30mm² THHN/THWN Cu WireIN 32 mm dia PVC

SERVICE ENTRANCE POLE

4650mm High

SERVICE DROP WIRE

2-14mm² THW CU WIREwith Messenger

SHEET NO.SUBMITTED BY: APPROVED BY:RECOMMEND APPROVAL:CHECKED BY:PREPARED BY:PROJECT TITLE:

LOCATION: LOCATION:

Republic of the PhilippinesNATIONAL POLICE COMMISSIONPHILIPPINE NATIONAL POLICE

Camp Quintin M Merecido, Davao City

Kidalapong, Malita, Davao Occidental

PROPOSED FIRING RANGE

ENGINEERING SERVICE

REGIONAL PROJECT MANAGEMENT UNIT 11

Director, ES

Police Chief SuperintendentPHILIP LAWRENCE S ABAPO, IIIPOLICE SENIOR INSPECTOR

ANTONIO A TAYLAN, JR

Asst. Chief, RPMU

MARIA DEOVINA G SEVILLANOPolice Chief Inspector

Acting Chief, RPMU

ABELARDO C MATILLANOPolice Senior Superintendent

Chief of Staff, ES

MANUEL G FABROSPolice Senior Superintendent

Deputy Director, ES

DAVAO OCCIDENTAL POLICE PROVINCIAL OFFICE

Acting Chief, ID, ES

HONORIO R AGNILAPolice Superintendent

E-1

M CR F CR

UT

ILIT

Y

ROOFLINE ABOVE

BU

LLE

TIN

BO

AR

D

BAY

1

BAY

2

BAY

3

BAY

4

BAY

5

RECEIVING

OFFICE

ARMORY

STORAGE

RANGE

OFFICER

LECTURE

ROOM

SNACK

BAR

BULLET TRAP

D O W N R A N G E

SHOOTERS AREA

BENCHESBENCHES

SHOOTERS LOUNGE AREA

B A C K S T O PSAND TRAP

P I S T O L F I R I N G R A N G E

1 SEE BACKSTOP DETAIL

ALUM FRAMED CLEAR GLASS ALUM FRAMED CLEAR GLASS

BULLET TRAPBULLET TRAP

2

1

3

4

5

6

7

8

CKT

NO.

Panel Board: SCHEDULE OF LOADSOCPD

No. & Size of Wire

and Conduit

DESCRIPTION LO COSPO

GFCITotal Volts kVA Amps

AT, AF, POLE,

kAICWIRE mm²/ PVC mmØ

1 Lighting Outlet 25 25 230 2.50 10.87 15, 50, 2, 6 2-3.5 THHN 20

2 Lighting Outlet 24 24 230 2.40 10.43 15, 50, 2, 6 2-3.5 THHN 20

3 Lighting Outlet 10 10 230 1.00 4.35 15, 50, 2, 6 2-3.5 THHN 20

4 Convenience Outlet 7 0 7 230 1.26 5.48 20, 50, 2, 6 2-3.5 THHN 20

5 Convenience Outlet 10 0 10 230 1.80 7.83 20, 50, 2, 6 2-3.5 THHN 20

6 Convenience Outlet 9 0 9 230 1.62 7.04 20, 50, 2, 6 2-3.5 THHN 20

7 1.5HP WT ACU 1 1 230 2.30 10.00 20, 50, 2, 6 2-5.5 THHN 25

8 1HP WT ACU 1 1 230 1.38 6.00 20, 50, 2, 6 2-5.5 THHN 25

9 SPARE 0 0 230 1.84 8.00 20, 50, 2, 6 25

10 SPARE 0 0 230 1.84 8.00 20, 50, 2, 6 25

Sub-total 59 26 2 87 17.94 78.00

COMPUTATIONS OF LOADS: PANEL BOARD

Iw (Ampacity of Wire)= (Total current, It x Demand factor,df) + 25 of Largest motor

Iw (Wire ampacity) = 78.00 + 2.50 = 80.50 USE: 2 - 30 mm² THHN/THWN in 32 mm Ø RSC PIPEIcb (Main Over Current Protection Device)= Iw + Largest motor

Icb (Main OCPD) = 80.50 + 10.00 = 90.50 10 Branches Panel Board, 100AF with 100 AT Main CB, Bolt-on, Center Main, 2 Pole, 240V, 60Hz

with Grounding Lugs

1

3

2

SijSghSefScdSab

SF3Sab SefScd

Sa Sde

Sa

Sa

Sa

Sa

Sa

Sabc

Sa

SF2Sabc

a a a

a

a a

a

b d

c

c

d

e e

e e

f

a

a b c

b c

a

a

a c

a c

cbb

PROFESSIONAL ELECTRICAL ENGINEER

REG NO: PTR NO: TIN:

ISS. AT: ISS. ON: TEL:

NOTE: Sign and Seal of Electrical plans is the sole authority of a PROFESSIONAL ELECTRICAL

ENGINEER

R.A. 7920 Section 31, 32 & 34. Field of Practice and Prohibition in the Practice of Electrical

Engineering and preparation of plans, supervision of installation, application of the Philippine

Electrical Code.

It shall be unlawful for any person not authorized under this Act to prepare plans,

electrical valuations or specifications for any electrical wiring, equipment or system; and no

installation thereof shall be undertaken unless the plans, designs, valuations and specifications

have been prepared by or under the responsible charge of, and signed and sealed by a

professional electrical engineer; and the construction permit for the execution thereof is first

secured; and unless the work is done in accordance with the Philippine Electrical Code and is

executed under the responsible charge or supervision of a PROFESSIONAL ELECTRICAL

ENGINEER or REGISTERED ELECTRICAL ENGINEER or Registered Master Electrician, as the

case may be, and the routinary fiscal and ministerial requirements of the government agency, if

any, exercising jurisdiction over the particular installation have been complied with.

SF2

Sb

a

a

b

FLOOR PLAN1SCALE 1:100MTS

LIGHTING LAYOUT

TABLE OF CONTENTS

SHEET

NOSHEET CONTENTS

DRAWING

NO

E1 LIGHTING LAYOUT 1

SCHEDULE OF LOAD & COMPUTATIONS 2

SHEET NO.SUBMITTED BY: APPROVED BY:RECOMMEND APPROVAL:CHECKED BY:PREPARED BY:PROJECT TITLE:

LOCATION: LOCATION:

Republic of the PhilippinesNATIONAL POLICE COMMISSIONPHILIPPINE NATIONAL POLICE

Camp Quintin M Merecido, Davao City

Kidalapong, Malita, Davao Occidental

PROPOSED FIRING RANGE

ENGINEERING SERVICE

REGIONAL PROJECT MANAGEMENT UNIT 11

Director, ES

Police Chief SuperintendentPHILIP LAWRENCE S ABAPO, IIIPOLICE SENIOR INSPECTOR

ANTONIO A TAYLAN, JR

Asst. Chief, RPMU

MARIA DEOVINA G SEVILLANOPolice Chief Inspector

Acting Chief, RPMU

ABELARDO C MATILLANOPolice Senior Superintendent

Chief of Staff, ES

MANUEL G FABROSPolice Senior Superintendent

Deputy Director, ES

DAVAO OCCIDENTAL POLICE PROVINCIAL OFFICE

Acting Chief, ID, ES

HONORIO R AGNILAPolice Superintendent

E-2

PROFESSIONAL ELECTRICAL ENGINEER

REG NO: PTR NO: TIN:

ISS. AT: ISS. ON: TEL:

NOTE: Sign and Seal of Electrical plans is the sole authority of a PROFESSIONAL ELECTRICAL

ENGINEER

R.A. 7920 Section 31, 32 & 34. Field of Practice and Prohibition in the Practice of Electrical

Engineering and preparation of plans, supervision of installation, application of the Philippine

Electrical Code.

It shall be unlawful for any person not authorized under this Act to prepare plans,

electrical valuations or specifications for any electrical wiring, equipment or system; and no

installation thereof shall be undertaken unless the plans, designs, valuations and specifications

have been prepared by or under the responsible charge of, and signed and sealed by a

professional electrical engineer; and the construction permit for the execution thereof is first

secured; and unless the work is done in accordance with the Philippine Electrical Code and is

executed under the responsible charge or supervision of a PROFESSIONAL ELECTRICAL

ENGINEER or REGISTERED ELECTRICAL ENGINEER or Registered Master Electrician, as the

case may be, and the routinary fiscal and ministerial requirements of the government agency, if

any, exercising jurisdiction over the particular installation have been complied with.

FLOOR PLAN1SCALE 1:100MTS

SERVICE ENTRANCE

2-WIRE, SINGLE PHASE

kWhr METER

CLASS 1002-30mm² THW Cu Wirein 32mm Ø PVC Pipe

1

3

5

2

4

6

LIGHTING OUTLET

RECEPTACLE OUTLET

LIGHTING OUTLET

RECEPTACLE OUTLET

PANELBOARD

1HP WT ACU

SINGLE LINE DIAGRAM

M

MAIN SERVICE EQUIPMENT

100AT in NEMA 3R Enclosures

(OPTIONAL, FOR MORE THAN 30m ONLY)

2-30mm² THW Cu Wirein 32mm Ø RSC Pipe

SERVICE ENTRANCE POLE

4650mm High

SERVICE ENTRANCE

SINGLE PHASE, 240VAC, 60Hz

2 - 14 mm² THHN/THWN Cu Wirewith Messenger

DRIP LOOP

at least 1500

58" Ø EYEBOLT

GALVANIZED with SPOOL INSULATOR

KWHR METER

USE SOLDERLESS

CONNECTORS

DP100 AT

32 mm Ø RSC with clamps2-30mm² THHN Cu Wire

DETAIL OF SERVICE ENTRANCE

N. G. L.

SERVICE POLE DETAILNOT TO SCALE

TOP

STEEL BARS

STIRRUPS

4 STEEL BARS

BOTHWAYS

NOTE: COORDINATE TO THE

STRUCTURAL ENGINEER FOR

THE SIZE OF STEEL BARS

NGL

2 - 14mm² THHN/THWN Cu Wirewith Messenger SERVICE DROP LINE

2 - 30mm² THHN/THWN Cu Wirein 32 mm dia PVC

100 AT2P

7 8

M CR F CR

UT

ILIT

Y

ROOFLINE ABOVE

BU

LLE

TIN

BO

AR

D

BAY

1

BAY

2

BAY

3

BAY

4

BAY

5

RECEIVING

OFFICE

ARMORY

STORAGE

RANGE

OFFICER

LECTURE

ROOM

SNACK

BAR

BULLET TRAP

D O W N R A N G E

SHOOTERS AREA

BENCHESBENCHES

SHOOTERS LOUNGE AREA

B A C K S T O PSAND TRAP

P I S T O L F I R I N G R A N G E

1 SEE BACKSTOP DETAIL

ALUM FRAMED CLEAR GLASS ALUM FRAMED CLEAR GLASS

BULLET TRAPBULLET TRAP

2

1

3

4

5

6

7

8

7

3

4

5

6

9 10SPARE SPARE

LIGHTING OUTLET

1.5HP WT ACU

RECEPTACLE OUTLET

15 AT2P

15 AT2P

20 AT2P

20 AT2P

20 AT2P

15 AT2P

20 AT2P

20 AT2P

20 AT2P

20 AT2P

POWER LAYOUT

TABLE OF CONTENTS

SHEET

NOSHEET CONTENTS

DRAWING

NO

E3 POWER LAYOUT 1

SINGLE LINE DIAGRAM 2

DETAIL OF SERVICE ENTRANCE 3

SERVICE ENTRANCE POLE

4650mm High

2 - 30mm² THHN/THWN Cu WireIN 32 mm dia PVC

SHEET NO.SUBMITTED BY: APPROVED BY:RECOMMEND APPROVAL:CHECKED BY:PREPARED BY:PROJECT TITLE:

LOCATION: LOCATION:

Republic of the PhilippinesNATIONAL POLICE COMMISSIONPHILIPPINE NATIONAL POLICE

Camp Quintin M Merecido, Davao City

Kidalapong, Malita, Davao Occidental

PROPOSED FIRING RANGE

ENGINEERING SERVICE

REGIONAL PROJECT MANAGEMENT UNIT 11

Director, ES

Police Chief SuperintendentPHILIP LAWRENCE S ABAPO, IIIPOLICE SENIOR INSPECTOR

ANTONIO A TAYLAN, JR

Asst. Chief, RPMU

MARIA DEOVINA G SEVILLANOPolice Chief Inspector

Acting Chief, RPMU

ABELARDO C MATILLANOPolice Senior Superintendent

Chief of Staff, ES

MANUEL G FABROSPolice Senior Superintendent

Deputy Director, ES

DAVAO OCCIDENTAL POLICE PROVINCIAL OFFICE

Acting Chief, ID, ES

HONORIO R AGNILAPolice Superintendent

E-3

ALL PLUMBING WORKS SHALL BE DONE IN ACCORDANCE W THE LATEST PROVISIONS

ALL VERT SOIL & WASTE STACK PIPE SHALL BE EXTEND FULL SIZE ABOVE ROOF LINE

PROVIDE 50MM Ø P-TRAP FOR EVERY 100M M Ø X 100MM Ø FLR DRAIN

PROVIDE CLEANOUT FOR EVERY FIFTEEN METERS ( 15.00 M ) DISTANCE

ALL CHANGES IN PIPE SIZES ON SOIL WASTE LINE SHALL BE MADE W THE REDUCING

OF THE NATIONAL PLUMBING CODE

AS VENTS EXCEPT OTHERWISE SPECIFICALLY INDICATED

FITTINGS OR RECESS REDUCERS

HORIZONTAL LINE

PROVIDE STOP-COCK FOR EVERY FIXTURES

12

0m

m

LIFTING COVER

R.C. COVER W STL

STORM DRAINAGE

PIPE LINE

4-12Ø MM

10 MM O BARSCHB WALL W

BARS BOTHWAYS

10 MM THK

DRAIN LINE

PLASTERED FIN.

LIFTING COVER

R.C. COVER W STL

SECTION

CO CLEAN-OUT

FD FLOOR DRAIN

SHO SHOWER

CV CHECK VALVE

GV GATE VALVE

VSTR VENT STACK THRU ROOF

M WATER METERLAV LAVATORY

WC WATER CLOSET

SV SEPTIC VAULT

URI URINAL

DS DOWNSPOUT

PVC POLYVINYL CHLORIDE

DRAINAGE PIPE LINE

LAV LAVATORY

WC WATER CLOSET

UR URINAL

COLD WATER LINEP L A N

NOTE:

VERIFY SIZE OF SEPTIC TANK TO LOCATION

.40 X .40

6" CHB

MANHOLE

4" CHB

6" CHB

12MM BARSSPACED @ .20M

O.C BW

S E C T I O N

AIR SPACEWATER LEVEL

CHAMBERDIGESTIVE

.40M

WF1

12 LIFT BAR

AIR SPACEWATER LEVEL

CHAMBERLEACHING

CHAMBERLEACHING

21

12MM BARSSPACED @ .20M

O.C BW

4" CHB6" CHB

TO

MA

IN

SE

WE

R L

INE

OU

TL

ET

PIP

E

TO

SE

PT

IC V

AU

LT

INL

ET

PIP

E

TO MAIN SEWER LINEOUTLET PIPE

TO

SEPTIC VAULTINLET PIPE

FAU FAUCET

PLAN

WATER LEVELAIR SPACE

SOIL PIPE LINE

CB CATCH BASIN

VENT PIPE LINE

PPR POLYPROPYLENE RANDOM

NOT TO SCALE

1

P1 NOT TO SCALE

1

P2

SHEET NO.SUBMITTED BY: APPROVED BY:RECOMMEND APPROVAL:CHECKED BY:PREPARED BY:PROJECT TITLE:

LOCATION: LOCATION:

Republic of the PhilippinesNATIONAL POLICE COMMISSIONPHILIPPINE NATIONAL POLICE

Camp Quintin M Merecido, Davao City

Kidalapong, Malita, Davao Occidental

PROPOSED FIRING RANGE

ENGINEERING SERVICE

REGIONAL PROJECT MANAGEMENT UNIT 11

Director, ES

Police Chief SuperintendentPHILIP LAWRENCE S ABAPO, IIIPOLICE SENIOR INSPECTOR

ANTONIO A TAYLAN, JR

Asst. Chief, RPMU

MARIA DEOVINA G SEVILLANOPolice Chief Inspector

Acting Chief, RPMU

ABELARDO C MATILLANOPolice Senior Superintendent

Chief of Staff, ES

MANUEL G FABROSPolice Senior Superintendent

Deputy Director, ES

DAVAO OCCIDENTAL POLICE PROVINCIAL OFFICE

Acting Chief, ID, ES

HONORIO R AGNILAPolice Superintendent

P-1

BULLET TRAP

D O W N R A N G E

B A C K S T O PSAND TRAP

SANITARY LINES LAYOUT1SCALE 1:100MTS

1 SEE BACKSTOP DETAIL

BULLET TRAPBULLET TRAP

E

2

1

3

4

5

6

7

8

CBA D

CO

VTRLAV

LAVFDFD

WCWC

UR

BULLET TRAP

D O W N R A N G E

B A C K S T O PSAND TRAP

WATER LINES LAYOUT1SCALE 1:100MTS

1 SEE BACKSTOP DETAIL

BULLET TRAPBULLET TRAP

E

2

1

3

4

5

6

7

8

CBA D

WM

CV

GV

FAUFAU

LAVLAV

WC WC

UR

SHEET NO.SUBMITTED BY: APPROVED BY:RECOMMEND APPROVAL:CHECKED BY:PREPARED BY:PROJECT TITLE:

LOCATION: LOCATION:

Republic of the PhilippinesNATIONAL POLICE COMMISSIONPHILIPPINE NATIONAL POLICE

Camp Quintin M Merecido, Davao City

Kidalapong, Malita, Davao Occidental

PROPOSED FIRING RANGE

ENGINEERING SERVICE

REGIONAL PROJECT MANAGEMENT UNIT 11

Director, ES

Police Chief SuperintendentPHILIP LAWRENCE S ABAPO, IIIPOLICE SENIOR INSPECTOR

ANTONIO A TAYLAN, JR

Asst. Chief, RPMU

MARIA DEOVINA G SEVILLANOPolice Chief Inspector

Acting Chief, RPMU

ABELARDO C MATILLANOPolice Senior Superintendent

Chief of Staff, ES

MANUEL G FABROSPolice Senior Superintendent

Deputy Director, ES

DAVAO OCCIDENTAL POLICE PROVINCIAL OFFICE

Acting Chief, ID, ES

HONORIO R AGNILAPolice Superintendent

P-2

FO

UN

DA

TIO

N P

LAN

1S

CA

LE1:

100M

TS

E

21 3 4 5 6 7 8

CB

AD

C1F

1C

1F

1

C1F

1C

1F

1

C1F

1C

1F

1

C1F

2C

1F

2

C1F

3

C1F3

C1F

3

P1F3

SC

HE

DU

LE

OF

FO

OT

ING

S

P1F

2P

1F

2

P1F3P1F2P1F

3P

1F

3

P2F

4P

2F

4P

2F

4P

2F

4

P1F3P1F3P1F2 C1F3

C1F3C1F3

WF

1

WF

2

WF

1

WF1

WF1

WF

1

WF1

WF

1W

F1

WF

1

WF1WF1WF1WF1WF1

WF1WF1WF1WF1WF1WF1

WF

1W

F1

WF

1

WF

2W

F2

WF

2

WF

2W

F2

WF

2W

F2

NA

TU

RA

L

GR

AD

E L

INE

10Ø

@ 3

00

600 E

AC

H W

AY

WAL

L W

/ 10Ø

@150 T

HK

. C

HB

(TY

PIC

AL)

3-10

Ø

750 (MIN.)

200

400

150

10Ø

@ 3

00

3-10

Ø

10Ø

@ 3

00E

AC

H W

AY

100 T

HK

. S

LA

BO

N G

RA

DE

W

600 E

AC

H W

AY

(TY

PIC

AL)

WAL

L W

/ 10Ø

@100 T

HK

. C

HB

300

100

100

100

100

300

WF-

2 D

ETA

IL

WF-

1 D

ETA

IL

100

L

FOO

TIN

GS

& C

OLU

MN

S

L

Tariable

CO

LUM

N F

OO

TIN

G1

SC

ALE

NT

S

PLA

N

SEC

TIO

N

WA

LL F

OO

TIN

G D

ET

AIL

S1

SC

ALE

NT

S

CO

LUM

N P

LAN

SHEET NO.SUBMITTED BY: APPROVED BY:RECOMMEND APPROVAL:CHECKED BY:PREPARED BY:PROJECT TITLE:

LOCATION: LOCATION:

Republic of the PhilippinesNATIONAL POLICE COMMISSIONPHILIPPINE NATIONAL POLICE

Camp Quintin M Merecido, Davao City

Kidalapong, Malita, Davao Occidental

PROPOSED FIRING RANGE

ENGINEERING SERVICE

REGIONAL PROJECT MANAGEMENT UNIT 11

Director, ES

Police Chief SuperintendentPHILIP LAWRENCE S ABAPO, IIIPOLICE SENIOR INSPECTOR

ANTONIO A TAYLAN, JR

Asst. Chief, RPMU

MARIA DEOVINA G SEVILLANOPolice Chief Inspector

Acting Chief, RPMU

ABELARDO C MATILLANOPolice Senior Superintendent

Chief of Staff, ES

MANUEL G FABROSPolice Senior Superintendent

Deputy Director, ES

DAVAO OCCIDENTAL POLICE PROVINCIAL OFFICE

Acting Chief, ID, ES

HONORIO R AGNILAPolice Superintendent

S-1

RO

OF

FR

AM

ING

PLA

N1

SC

ALE

1:10

0MT

S

E

21 3 4 5 6 7 8

CB

AD

R A F T E R - 2

R A F T E R - 2

R A F T E R - 2

R A F T E R - 2

R A F T E R - 1

R A F T E R - 1

12MM Ø SAG ROD

12MM Ø SAG ROD

12MM Ø SAG ROD

LINTEL BEAM 1

RO

OF

BE

AM

-1

RO

OF

BE

AM

-1

RO

OF

BE

AM

-1

RO

OF

BE

AM

-1

LINTEL BEAM 2

RO

OF

BE

AM

-2

RO

OF

BE

AM

-2

RO

OF

BE

AM

-2

RO

OF

GIR

T -

1

RO

OF

GIR

T-2

RO

OF

GIR

T-2

R A F T E R-3

R A F T E R-3

R A F T E R-3

R A F T E R-3

R A F T E R-3

R A F T E R-3

12MM Ø SAG ROD

12MM Ø SAG ROD

R A F T E R - 1

LINTEL BEAM 2

LINTEL BEAM 2 LINTEL BEAM 2

RO

OF

GIR

T -

1R

OO

F G

IRT

- 1

LINTEL BEAM 1

SC

HE

DU

LE O

F B

EA

MS

SHEET NO.SUBMITTED BY: APPROVED BY:RECOMMEND APPROVAL:CHECKED BY:PREPARED BY:PROJECT TITLE:

LOCATION: LOCATION:

Republic of the PhilippinesNATIONAL POLICE COMMISSIONPHILIPPINE NATIONAL POLICE

Camp Quintin M Merecido, Davao City

Kidalapong, Malita, Davao Occidental

PROPOSED FIRING RANGE

ENGINEERING SERVICE

REGIONAL PROJECT MANAGEMENT UNIT 11

Director, ES

Police Chief SuperintendentPHILIP LAWRENCE S ABAPO, IIIPOLICE SENIOR INSPECTOR

ANTONIO A TAYLAN, JR

Asst. Chief, RPMU

MARIA DEOVINA G SEVILLANOPolice Chief Inspector

Acting Chief, RPMU

ABELARDO C MATILLANOPolice Senior Superintendent

Chief of Staff, ES

MANUEL G FABROSPolice Senior Superintendent

Deputy Director, ES

DAVAO OCCIDENTAL POLICE PROVINCIAL OFFICE

Acting Chief, ID, ES

HONORIO R AGNILAPolice Superintendent

S-2

6MM X 100MM

W - FLANGE GIRT

G.I. LONG SPAN ROOF SHEETS

2" X 3" C-PURLINS

6MM X 100MM W FLANGE RAFTER

10MM Ø SAG ROD

2" X 6" C-PURLINS

8MM X 150MM W-FLANGE (RAFTER)

G.I. LONG SPAN ROOF SHEETS

G.I. LONG SPAN ROOF SHEETS

2" X 4" C-PURLINS

8MM X 200MM W-FLANGE (RAFTER)

10MM Ø SAG ROD

5 6 7 8

DETAILED SECTION OF ROOF1SCALE 1:30MTS

8MM X 250MM

W-FLANGE

(ROOF GIRT)

L I N T E L B E A M - 2 L I N T E L B E A M - 2

L I N T E L B E A M - 1

5-20MMØ TOP BARS

2-20MMØ BOT BARS

12MMØ STIFFENER BARS

2-20MMØ TOP BARS

5-20MMØ BOT BARS

12MMØ STIFFENER BARS

3-16MMØ TOP BARS

2-16MMØ BOT BARS

12MMØ STIFFENER BARS

2-16MMØ TOP BARS

3-16MMØ BOT BARS

12MMØ STIFFENER BARS

4-16MMØ TOP BARS

2-16MMØ BOT BARS

2-16MMØ TOP BARS

4-16MMØ BOT BARS

3-16MMØ TOP BARS

2-16MMØ BOT BARS

2-16MMØ TOP BARS

3-16MMØ BOT BARS

ROOF BEAM -1

@ SUPPORT @ MIDSPAN

@ SUPPORT @ SUPPORT

@ SUPPORT @ MIDSPAN

@ MIDSPAN @ MIDSPAN

ROOF BEAM -2

ROOF BEAM -3

ROOF BEAM -4

DETAIL OF BEAMS SCALE 1:20MTS

4" Ø SCHEDULE 40G.I. PIPE POST

ROOF BEAM - 2

ROOF BEAM - 1

ROOF BEAM - 1

SHEET NO.SUBMITTED BY: APPROVED BY:RECOMMEND APPROVAL:CHECKED BY:PREPARED BY:PROJECT TITLE:

LOCATION: LOCATION:

Republic of the PhilippinesNATIONAL POLICE COMMISSIONPHILIPPINE NATIONAL POLICE

Camp Quintin M Merecido, Davao City

Kidalapong, Malita, Davao Occidental

PROPOSED FIRING RANGE

ENGINEERING SERVICE

REGIONAL PROJECT MANAGEMENT UNIT 11

Director, ES

Police Chief SuperintendentPHILIP LAWRENCE S ABAPO, IIIPOLICE SENIOR INSPECTOR

ANTONIO A TAYLAN, JR

Asst. Chief, RPMU

MARIA DEOVINA G SEVILLANOPolice Chief Inspector

Acting Chief, RPMU

ABELARDO C MATILLANOPolice Senior Superintendent

Chief of Staff, ES

MANUEL G FABROSPolice Senior Superintendent

Deputy Director, ES

DAVAO OCCIDENTAL POLICE PROVINCIAL OFFICE

Acting Chief, ID, ES

HONORIO R AGNILAPolice Superintendent

S-3