thin multiples installation guide - juniper › wp-content › uploads › 2018 › 07 ›...

6
24" DYAD VERTICAL CONFIGURATION, 3 CONNECTED SECTIONS 24" DYAD HORIZONTAL CONFIGURATION, 5 CONNECTED SECTIONS 24" TRIAD CONFIGURATION, 2 CONNECTED SECTIONS 36" TETRAD CONFIGURATION THIN Multiples Installation Guide Designed by Peter Bristol & Juniper 1

Upload: others

Post on 28-Jun-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: THIN Multiples Installation Guide - Juniper › wp-content › uploads › 2018 › 07 › JPR... · 2020-02-05 · only a licensed electrician should perform installation disconnect

24" DYAD VERTICAL CONFIGURATION, 3 CONNECTED SECTIONS

24" DYAD HORIZONTAL CONFIGURATION, 5 CONNECTED SECTIONS

24" TRIAD CONFIGURATION, 2 CONNECTED SECTIONS

36" TETRAD CONFIGURATION

THIN MultiplesInstallation Guide

Designed by Peter Bristol & Juniper

1

Page 2: THIN Multiples Installation Guide - Juniper › wp-content › uploads › 2018 › 07 › JPR... · 2020-02-05 · only a licensed electrician should perform installation disconnect

72" for 24" light tube or 96" for 36" light tube

6' M

INIM

UM

A B B/C B B C

CASE - B

MINI MOUNTING PLATE

FOR IN-CEILING WIRING AND FIXTURES MOUNTED TO THE CEILING.

SEE PAGE 4 FOR DETAILED INSTALLATION AND WIRING INFORMATION.

CANOPY PLATE

FOR FIXTURES WIRED TO A JUNCTION BOX.

SEE PAGE 3 FOR DETAILED INSTALLATION AND WIRING INFORMATION.

*CANOPY PLATE

72" or 96"

1 14 " 1 1

4 "

*MINI MOUNTING PLATE

48" or 72"72" or 96"

For CASE - BONLY

1 14 " 1 1

4 "

6' MINIMUM

48" or 72"72" or 96"

For CASE - BONLY

48" for 24" light tube or 72" for 36" light tube

A B/C B C

CASE - A

48" or 72"

*CANOPY PLATE

KEYA

B

C

POWER SLEEVES MOUNTED BENEATH *CANOPY PLATE OR *MINI MOUNTING PLATE AT POWER END OF THE FIXTURE (SEE POWER FEED OPTIONS).

PASSTHROUGH SLEEVES USED TO CONNECT SEGMENTS TOGEHTER. MOUNTED IN BETWEEN POWER SLEEVES AND END SLEEVES.

END SLEEVES MOUNTED AT THE END OF THE FIXTURE.

WARNING

ONLY A LICENSED ELECTRICIAN SHOULD PERFORM INSTALLATIONDISCONNECT MAIN POWER AT THE SOURCE PRIOR TO INSTALLATION

INSTRUCTIONS MEANT FOR AN INDEPENDENT REMOTE DRIVER RATED CLASS 2 24V DC AT THE CONNECTIONS ONLY (NOT 120V AC)

MARK MOUNTING POINTS

*POWER FEED OPTIONS

THIN MULTIPLES INSTALLATION GUIDE 2

WWW.JUNIPER-DESIGN.COM | [email protected] | +1 347 799-2915 | 68 33RD STREET, UNIT 11, BROOKLYN, NY 11232

THIN MULTIPLES INSTALLATION GUIDE

WWW.JUNIPER-DESIGN.COM | [email protected] | +1 347 799-2915 | 68 33RD STREET, UNIT 11, BROOKLYN, NY 11232

Page 3: THIN Multiples Installation Guide - Juniper › wp-content › uploads › 2018 › 07 › JPR... · 2020-02-05 · only a licensed electrician should perform installation disconnect

Remove gripper from the canopy plate to release the crossbar.

1

Attach the crossbar to the junction box using provided screws.

2

White Lead(+)from fixture

Silver Shielding(-)from fixture

+ 24VDC leadfrom remote driver

- 24VDC lead from remote driver

4Connect the ground wire to ground screw on crossbar.

3

Partly unscrew safety nut on gripper, feed aircraft cable on power end through. Suspend an extra 2 feet of aircraft cable, more than the planned height of fixture.

FOR COLLAR PINCHING TWO AIRCRAFT CABLES, REFER TO 5-A IN INSTRUCTIONS

Threaded nut

CASE - A

FOR COLLAR PINCHING THREE AIRCRAFT CABLES, REFER TO 5-B IN INSTRUCTIONS

Gripper

CASE - B

5-A

Place wires inside junction box and screw threaded rod into crossbar to mount canopy plate to junction box. Screw the nut over the threaded rod to cover it.

5-B

Place wires inside junction box and screw gripper into crossbar to mount canopy plate to junction box. Partly unscrew safety nut on gripper. Feed aircraft cable to the gripper.

Pass power cable through bushing, and wire according to diagram.

CEILING FIXTURE INSTALLATION WITH CANOPY PLATE

CANOPY PLATE CONFIGURATIONS

THIN MULTIPLES INSTALLATION GUIDE 3

WWW.JUNIPER-DESIGN.COM | [email protected] | +1 347 799-2915 | 68 33RD STREET, UNIT 11, BROOKLYN, NY 11232

Page 4: THIN Multiples Installation Guide - Juniper › wp-content › uploads › 2018 › 07 › JPR... · 2020-02-05 · only a licensed electrician should perform installation disconnect

7

Adjust aircraft cable length as needed. Press safety nut on gripper to loosen aircraft cable. Screw safety nut in completely when finished. Do not cut extra aircraft cable until full fixture is assembled and working.

INSTALL AT "A" MOUNTING POINTS ONLY

INSTALL AT "B" & "C" MOUNTING POINTS

Woodscrews are provided for default installs. Alternate screws may be used at the recommendation of a licensed electrician.

34 "

DRILL 1/2" HOLEFOR BUSHING

"A" MOUNTING POINT

CEILING FIXTURE INSTALLATION WITH MINI MOUNTING PLATE

3

Screw gripper into ceiling post. Partly unscrew safety nut on gripper and feed aircraft cables through. Suspend an extra 2 feet of aircraft cable more than the planned height of the fixture on all grippers except "CASE - B ONLY" gripper (See page 2).

Adjust aircraft cable lengths as needed. Press safety nut on gripper to loosen aircraft cable. Screw safety nut in completely when finished.Do not cut extra aircraft cable until full fixture is assembled and working.

2

Install using provided screws according to diagram.

Pass power cable through bushing and wire to electrician-provided 18AWG in-wall rated cable (recommended).

Drill hole for bushing according to diagram.

1

4 5

*Only applicable to more than one connected sections for "CASE - A" or more than two sections for "CASE - B"

Install ceiling posts at all B and C mounting points using provided screws. Screw grippers into ceiling posts.

Woodscrews are provided for default installs. Alternate screws may be used at the recommendation of a licensed electrician.

6 (*IF APPLICABLE)

THIN MULTIPLES INSTALLATION GUIDE 4

WWW.JUNIPER-DESIGN.COM | [email protected] | +1 347 799-2915 | 68 33RD STREET, UNIT 11, BROOKLYN, NY 11232

Page 5: THIN Multiples Installation Guide - Juniper › wp-content › uploads › 2018 › 07 › JPR... · 2020-02-05 · only a licensed electrician should perform installation disconnect

CARE INSTRUCTIONS

Brass will patina over time like other natural metals and regular care is required in order to retain the quality finish of you THIN fixture for years to come.

Gently wipe with a damp cloth to remove dirt, dust and fingerprints.

Use indoors only.

2. Install collar on other aircraft cables, if applicableto your fixture's configuration.

3. Reconnect the main power and Insert light tubes into the power end. Push the light tubes carefully until they illuminate.

4. Push following sleeve onto illuminated light tubes. Add light tubes and sleeves as needed according to your fixture's configuration.

1. Install collar on aircraft cables at the power end as shown.

3. Install the light segment in the middle by carefully pushing the segment all the way into the passthrough sleeve,if applicable to your fixture's configuration.

2. Install collar on other aircraft cables, if applicable to your fixture's configuration.

4. Reconnect the main power and Insert light tubes into the power end. Push the light tube carefully until they illuminate.

5. Push following sleeve onto illuminated light tubes. Add light tubes and sleeves as needed according to your segment configuration.

6. Slide the end sleeve onto the last set of light tubes.

1. Install collar on aircraft cables at the power end as shown.

LIGHT SEGMENT INSTALLATION

The THIN Multiples fixture is designed with an inventive magnetic connection. Simply insert the light tubes into their sleeves for electrical contact to be made.

CASE - A: SINGLE SEGMENT COLLAR INSTALL

CASE - B: DOUBLE SEGMENT COLLAR INSTALL

5. Slide the end sleeve onto the last set of light tubes.

THIN MULTIPLES INSTALLATION GUIDE 5

WWW.JUNIPER-DESIGN.COM | [email protected] | +1 347 799-2915 | 68 33RD STREET, UNIT 11, BROOKLYN, NY 11232

Page 6: THIN Multiples Installation Guide - Juniper › wp-content › uploads › 2018 › 07 › JPR... · 2020-02-05 · only a licensed electrician should perform installation disconnect

INSTALL AT "A" MOUNTING POINTS ONLY

INSTALL AT "B" & "C" MOUNTING POINTS

34 "

DRILL 1/2" HOLEFOR BUSHING

"A" MOUNTING POINT

3. Partly unscrew safety nut on gripper, feed aircraft cables through.

Screw grippers into ceiling posts. Adjust aircraft cable lengths as needed. Press safety nut on gripper to loosen aircraft cable. Screw safety nut in completely when finished. Do not cut extra aircraft cable until full fixture is assembled and working.

Drill hole for bushing according to diagram. Install using provided screws according to diagram.

Pass power cable through bushing and wire to electrician-provided 18AWG in-wall rated cable (recommended).

2

4 5

1 3

THIN MULTIPLES INSTALLATION GUIDE 5

WWW.JUNIPER-DESIGN.COM | [email protected] | +1 347 799-2915 | 68 33RD STREET, UNIT 11, BROOKLYN, NY 11232