thermodesk ellure manual height adjustable desk - installation manual v1.0

8
ThermoDesk ELECTRAThermoDesk ELLURE TM Adjustable-Height Desk System INSTALLATION MANUAL VERSION 2.0

Upload: imovr

Post on 13-Jul-2015

210 views

Category:

Devices & Hardware


2 download

TRANSCRIPT

Page 1: ThermoDesk ELLURE Manual Height Adjustable Desk - Installation Manual v1.0

ThermoDesk ELECTRA™ Adjustable-Height Desk System

Installation Manual Version 1.0

ThermoDesk ELLURETM

Adjustable-Height Desk System

INSTALLATION MANUALVERSION 2.0

Page 2: ThermoDesk ELLURE Manual Height Adjustable Desk - Installation Manual v1.0

2

BEFORE YOU BEGINPROVIDED:

READ THIS:

(19) M6 hexagonal machine bolts

(10) 5x20 mm Machine Screws

(4) Foot Caps

(2) Support ArmsRight and Left

(2) Hex Wrenches (2) Feet

(2) Lifting LegsRight and Left

(1) Crank Handle

(1) Drive ShaftRight, left, and center

(2) CrossbarsIdentical

(1) Crank Shaft

Identical

(1) ELLURE table top

R

LR

L

CONGRATULATIONS on your purchase of a ThermoDesk ELLURE™ adjustable-height desk system! We designed this product to be as easy as possible to assemble, but if you have any questions during the assembly process please contact our Customer Care team using the information on the back page.

SHOULD you be installing your own table top on the ELLURE frame, be sure to drill pilot holes before inserting wood screws. The wood screws supplied with the ELLURE base should work with most table tops. It is critical to pay attention to the available depth for pilot holes so as not to damage the lamination of the table top surface.

Page 3: ThermoDesk ELLURE Manual Height Adjustable Desk - Installation Manual v1.0

3

the feet are compatible with both the right or left leg

ASSEMBLY INSTRUCTIONSCLEAR a good-sized area to lay out all components

and assemble the desk. Lay the table top down on the floor, laminate side down. If not on carpet, we recommend placing a soft blanket down first in order to protect the table top surface. Make sure the entire area is clear of any loose screws or debris, to avoid scratching the laminated surface. Alternatively, this can all be done on top of another table rather than on the floor. Be careful not to slide the table top while upside-down, to protect the laminate.

THE ELLURE base is designed to work with any table top, though assembly is easiest when using a genuine ELLURE table top. ELLURE table tops include threaded insert nuts that remove any confusion as to where to drill, the bit size to use, or how deep to drill. These recessed nuts also extend the life of the product, by preventing degradation of the wood fibers from over-tightening and from removing and reinstalling wood screws too many times.

1 PREPARE FOR ASSEMBLYFOR THIS STEP:

ATTACH one foot to each lifting leg with four (4) M6 machine bolts provided.

SET the right and left lifting legs upside down on the table. Ensure they are positioned correctly on the table top, referring to the diagram below. The right lifting leg will have the crank gear housing attached. Insert one end of each crossbar into the opposing ends of the lifting legs, connecting the two legs together.

2 ATTACH FEET AND SET CROSSBAR IN LEGS

FOR THIS STEP:

the right lifting leg has the crank shaft

housing module

CAUTION!

R L

Page 4: ThermoDesk ELLURE Manual Height Adjustable Desk - Installation Manual v1.0

4

ATTACH the left and right top arms to their respective lifting columns using four (4) M6 machine bolts for each top arm. Make sure the top support arms are facing outwards. Do not tighten these bolts all the way.

3 ATTACH ARMS TO LEGS FOR THIS STEP:

R

L

R

L

INSERT the two rods into the drive shaft. Position the drive shaft between the two legs and expand

the drive shaft until the two rods are inserted into their respective legs.

4 INSERT DRIVE SHAFT FOR THIS STEP:

1 2

3

aerial view of underside

drive shaft

Page 5: ThermoDesk ELLURE Manual Height Adjustable Desk - Installation Manual v1.0

5

INSERT the crank shaft into the crank gear housing on the right leg. Affix the crank shaft to

the top arm using three (3) M6 machine bolts.

6 ATTACH CRANK TO ARM FOR THIS STEP:

crank gear housingcrank shaft

EXTEND the base to the appropriate width, so that the holes in the base are aligned with the recessed nuts on the table top. Secure the base to the table top with the appropriate machine screws. You may now tighten the top arm screws from Step 3.

5 ATTACH BASE TO TABLE TOP FOR THIS STEP:

R

L

x3

x3

use the smaller hex wrench for the set screws

not provided

the four (4) set screws are located on the

bottom of the crossbars

Page 6: ThermoDesk ELLURE Manual Height Adjustable Desk - Installation Manual v1.0

6

FLIP the Desk upright, and insert the crank handle into the crank shaft.

8 FINISHED! FOR THIS STEP:

ATTACH a foot cap to the end of each foot.7 ATTACH FOOT CAPS FOR THIS STEP:

handle folds out of crank

Page 7: ThermoDesk ELLURE Manual Height Adjustable Desk - Installation Manual v1.0

7

WARRANTYTHE THERMODESK ELLURE warranty coverage includes 5 years on table tops, and 2 years on the base. The following limitations apply:

THIS WARRANTY only covers defects as specified herein and does not include defects or damages attributable to improper installation, misuse or normal surface weathering, or defects or damages caused by accidents or fire or other casualty or Acts of God, or any other causes or occurrences beyond the manufacturer’s control. The exclusive remedial action provided for the customer hereunder shall be repair, restoration or replacement of the components as are found to be defective.

TABLE TOP: The replacement of new materials for those as may be defective may result in a color variance in comparison to the originally installed laminates due to slight color or texture changes by laminate manufacturers and is not indicative of a defect. iMovR reserves the right to substitute such laminates as are then being manufactured and is only obligated to match color and quality with such products as it is manufacturing at the time of replacement.

THIS WARRANTY is limited to repair, restoration and/or replacement by iMovR of any defective unit provided the manufacturer: (a) receives a written, faxed or emailed notice of claim under this warranty, including sufficiently high resolution photographs that clearly show the nature of the damage, and (b) within 30 days after notice of claim, is in receipt of the defective unit at its place of business, unless this requirement is waived by iMovR. The manufacturer will arrange for retrieval of the defective product via its carrier-of-choice. In some cases the manufacturer may elect not to retrieve the defective component, and may opt to send a replacement product based only on photographic evidence of warrantied defects. If upon receipt and inspection of the returned component it is determined that the damage was not due to a manufacturing flaw but rather one of the exempted reasons stated above, the costs of shipping the units to and from the manufacturer, plus the cost of the replacement component, shall be charged back to the customer.

LIMITATION OF LIABILITY: IT IS UNDERSTOOD AND AGREED THAT MANUFACTURER’S LIABILITY, WHETHER IN CONTRACT, IN TORT UNDER ANY WARRANTY, IN NEGLIGENCE OR OTHERWISE, SHALL NOT EXCEED THE RETURN OF THE AMOUNT OF PURCHASE PRICE FOR THE DEFECTIVE ITEM PAID BY PURCHASER AND UNDER NO CIRCUMSTANCES SHALL SELLER BE LIABLE FOR SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES. NO ACTION, REGARDLESS OF FORM, ARISING OUT OF THE TRANSACTIONS UNDER THIS AGREEMENT MAY BE BROUGHT BY THE PURCHASER MORE THAN ONE YEAR AFTER THE CAUSE OF ACTION HAS ACCRUED.

PREVENTATIVE MAINTENANCE AND CLEANINGAFTER first week of use: Tighten down all screws and bolts.

CLEANING THE BASE: Clean the base frame by wiping it down with a microfiber cloth moistened with a standard household cleaning solution. Never use solvents or abrasive or corrosive compounds on the frame. The base should be cleaned at regular intervals to remove dust and dirt, and inspected for mechanical damage, wear and breaks - worn out parts should be replaced.

CLEANING THE TABLE TOP: All ThermoDesk table tops are manufactured with a “3D lamination” process that results in an extremely durable surface, similar to what is often used in hospital environments. As such it can stand up to most cleaning solutions without risk of discoloration or degradation. Anti-bacterial solutions may be used. Always test new cleaning solutions on a less-seen surface first before using on the entire table top.

TROUBLESHOOTINGIF one side of the Ellure is rising up or down but not the other, check that the drive shaft is connected to both legs.

Page 8: ThermoDesk ELLURE Manual Height Adjustable Desk - Installation Manual v1.0

8

SPECIFICATIONSDYNAMIC WEIGHT CAPACITY:

STATIC WEIGHT CAPACTIY:

HEIGHT ADJUSTMENT RANGE:

WIDTH ADJUSTMENT RANGE:

200 lbs.

From 29-¼” to 48-¾”

From 32-½” to 54”

390 lbs.

TRAVEL SPEED:

ADJUSTABLE:

MANUFACTURING ORIGIN:

1 inch per 3 cranks

Manual Crank

Made in China

LAMINATION TYPE:

AVAILABLE SIZES:

Surf(x) 3D

30”x42” | 30”x48” | 30”x60” | 30”x72”

EDGING:

SURFACE RATING:

MANUFACTURING ORIGIN:

Ultra-durable

Ergonomically-contoured “comfort edge”

Made in Michigan, USA

CONTACT:iMovR

HOURS:PHONE:FAX:E-MAIL:LIVE CHAT:

See www.iMovr.com/hours(888) 208-6770 or (425) 999-3550(425) [email protected]

THERMODESK ELLURE INSTALLATION MANUAL PART NO. DO-IM-ELLURE-INST

AVAILABLE OPTIONS FROM iMovRStowaway Ergonomic Keyboard Tray

Single and Dual-Arm LCD Monitor Stands

Grommet-mounted Dual-AC Power Socket

ELLURE Base

ELLURE Table Top

2

1

3

1

2

3