thermo scientific shandon pathology workstations and ... · 4 thermo scientific shandon gross-star...
TRANSCRIPT
1
Thermo Scientific Shandon Pathology Workstations and Workbenches
• Downdraft or back draft fume removal
• Stainless-steel construction
• Elevating or fixed-height work stations
• Hands-free controls
• Three efficient ventilation system options
2
Superior Functionality• Downdraft and/or back draft ventilation• Units with elevating or fixed-height work surface are available• Elevating units have user-adjustable work surface height of
33 to 41" (83.8 to 104.1cm)• Fixed-height units have a work surface height that is factory
set to your specification• Deep sink with cold/hot water faucet (removable for easy
cleaning)• Optional ½ hp disposal is available (please check with local
authorities before ordering a unit with a disposal; some areas prohibit the use of disposals)
• Hands-free foot pedal controls for cold/hot water faucet and optional formalin dispensing system
• Abundant light is directed to the work surface• Vacuum breaker-protected water supply• Appliances plug directly into the unit for convenient use• Ventilated base cabinet• Fume removal is efficient and quiet• Optional camera and monitor/keyboard brackets are available• Camera bracket slides along the width of the unit• Monitor bracket is designed to hold a thin flat-screen display
monitor• Each unit comes with an integral centimeter ruler on the
front lip of the tabletop, magnetic instrument bar, integral glove dispenser, and paper towel dispenser
• Built-in manifold rinse washes down wetted internal surfaces quickly
• Perforated grid plates for work surface (removable for easy cleaning)
Superior Quality• Standard Type 304 or optional Type 316 stainless-steel
construction• Rugged design provides stability and is built tough to
withstand years of extensive work without corrosion• Perforated grid plates are standard Type 316 stainless-steel
construction
Designed for Easy Shipping and Installation• All Gross-Star™ workstations ship in two convenient assemblies
t hat fit through a standard 32" (81.3cm) doorway• The two assemblies link firmly with easy-to-assemble plates
and fasteners• Units connect to facility cold/hot water supplies and drains• Units are hard wired to facility electrical system
Installed Depth from Back of Unit to Wall• For the purpose of room planning, backs of fixed-height units
can be flush to walls• Elevating units require approximately 1" (2.54cm) clearance
between the back of the unit and wall to accommodate height adjustment
Three Ventilation System Options• Recirculating exhaust models feature formaldehyde neutralizing
filters and an integral blower• External exhaust models include an integral blower for
short distances• Remote exhaust models connect to the facility exhaust system
Physical Specifications• Overall Dimensions (H x W x D): 84 to 92 x 60 x 30"
(213.4 to 233.7 x 152.4 x 76.2cm)• Work surface height within range of 33 to 41" (83.8 to
104.1 cm); 36" (91.4cm) on fixed-height units unless customer-specified otherwise with order
• Sink (W x L x D): 14 x 16 x 7.5" (35.6 x 40.6 x 19.1cm)• Top Piece Weight: Uncrated, 275 lb. (124.7kg); crated,
375 lb. (170.1kg)• Bottom Piece Weight: Uncrated, 400 lb. (181.4kg); crated,
500 lb.(226.8kg)
Electrical Specifications• 110 –120V, 60Hz, 1Ph• Draw 20 amps and require a separate 15-amp circuit for one
hospital-grade duplex ground fault current interrupter (GFCI) receptacle
Plumbing Specifications• ¾" (1.9cm) hot and cold water supply lines with shutoff
valves and 1½" (3.8cm) drain line must be supplied• ½" (1.3cm) industrial-grade flexible hoses with ¾" (1.9cm)
female hose fittings are supplied for connection to water supply lines
• 1½" (3.8cm) I.D. reinforced flexible hose is provided for connection to facility drain line
CertificationsUL/cUL (for 110-120V units only)
Hands-free foot pedal controls for standard cold/hot water faucet and optional formalin dispensing system.
Thermo Scientific Shandon Gross-Star Pathology Workstation
Vented Trash can.
3
On the Top: Optional camera bracket and standard instrument bar.
On the Bottom: Optional monitor/keyboard brackets.
Included With Product
Description Order Number
Work surface height within range of 33 to 41" (83.8 to 104.1 cm); 36" (91.4cm) on fixed-height units unless customer- specified otherwise with order
—
Downdraft ventilation —
Ventilated base cabinet —
Removable sink —
Cold/hot water faucet with foot pedal controls —
Manifold rinse with manual control —
Hand spray —
Duplex GFCI Electrical Receptacle —
Centimeter ruler on front lip of tabletop —
Adjustable lower shelf (W x D): 16 x 8" (40.6 x 20.3cm) —
Fixed upper shelf —
Fluorescent light —
Type 304 stainless-steel construction —
Integrated glove dispenser —
Waste formalin collection system with high-level alarm —
Magnetic instrument bar (instruments not included) P104393
Towel dispenser for C-fold towels 1070214
C-fold towels 104401
Ordering Information
Description Order Number
Elevating 110-120V, 60Hz, 1Ph models with right-hand sink and foot pedal controls
Recirculating exhaust via filters and integral blower
B21100
External exhaust via integral blower and facility duct (20' max.; not included)
B21101
Remote exhaust via facility duct and blower (not included)
B21102
Fixed-height 110-120V, 60Hz, 1Ph models with right-hand sink and foot pedal controls
Recirculating exhaust via filters and integral blower
B21103
External exhaust via integral blower and facility duct (20' max.; not included)
B21104
Remote exhaust via facility duct and blower (not included)
B21105
Elevating and fixed-height units with left-hand sinks, manual controls and/or 220-240V, 50/60Hz, 1Ph electrical ratings are available upon request.
Factory Installed Options• Waste formalin collection systems with alarms feature both
audible and visual alarms
Description Order Number
Disposal, ½ hp with rocker switch B21111
Back draft and downdraft fume capture system B21216
Back draft fume capture system (no downdraft) B21114
Fresh formalin dispensing system with foot pedal control and low-level alarm B21116
Hood assembly B21113
Task lamp (specify left or right side) B1001405
Type 316 stainless-steel construction Special Order
Accessories
Description Order Number
Adjustable shelf (W x D): 16 x 8" (40.6 x 20.3cm) B21203
Camera bracket B21125
Camera bracket adapter (for use with hood assembly only) B21126
Fresh formalin dispensing carboy 104395
Magnifier for B1001405 task lamp B1001326
Movable dictation recorder rack 10629
Movable requisition rack 105417
Photographic blue polyethylene dissecting board B36115
Shelf for Thermo Scientific Shandon MicroWriter™ Cassette labeler B21215
Splash shield on flexible arm (requires drilling for installation) B21201
Thin monitor/keyboard bracket B21110
Ventilated trash bin (specify left or right side) B21115
Gross-Star Pathology Workstation exhaust information continued to page 5.
4
Thermo Scientific Shandon Gross-Star Pathology Workbench
Superior Functionality • Downdraft and/or back draft ventilation• Units with elevating or fixed-height work surface
are available• Elevating units have user-adjustable work surface
height of 33 to 41" (83.8 to 104.1cm)• Fixed-height units have a work surface height that is
factory set to your specification• Deep sink with cold/hot water faucet (removable for
easy cleaning)• Optional ½ hp disposal is available (please check with
local authorities before ordering a unit with a disposal; some areas prohibit the use of disposals)
• Hands-free foot pedal controls for cold/hot water faucet and optional formalin dispensing system
• Vacuum breaker-protected water supply• Appliances plug directly into the unit for convenient use• Ventilated base cabinet• Fume removal is efficient and quiet• Each unit comes with an integral centimeter ruler on
the front lip of the tabletop and magnetic instrument bar• Built-in manifold rinse washes down wetted internal
surfaces quickly• Perforated grid plates for work surface (removable for
easy cleaning)
Superior Quality• Standard Type 304 or optional Type 316 stainless-steel
construction• Rugged design provides stability and is built tough to
withstand years of extensive work without corrosion• Perforated grid plates are standard Type 316 stainless-steel
construction
Designed for Quick and Easy Installation• Workbench fits through a standard 32" (81.3cm) doorway• Units connect to facility cold/hot water supplies
and drains• Units are hard wired to facility electrical system• Workbench ships in one convenient assembly
Installed Depth from Back of Unit to Wall• For the purpose of room planning, backs of fixed-height units
can be flush to walls• Elevating units require approximately 1" (2.54cm) clearance
between the back of the unit and wall to accommodate height adjustment
Physical Specifications• Overall Dimensions (H x W x D): 45 to 53 x 60 x 30"
(114.3 to 134.6 x 152.4 x 76.2cm)• Work surface height within range of 33 to 41" (83.8 to
104.1cm); 36" (91.4cm) on fixed-height units unless customer-specified otherwise with order
• Sink (W x L x D): 14 x 16 x 7.5" (35.6 x 40.6 x 19.1cm)• Weight: Uncrated, 425 lb. (192.8kg); crated, 550 lb. (249.5kg)
Electrical Specifications• 110 –120V, 60Hz, 1Ph• Draw 20 amps and require a separate 15 amp circuit for one
hospital-grade duplex ground fault current interrupter (GFCI) receptacle
Plumbing Specifications• ¾" (1.9cm) hot and cold water supply lines with shutoff
valves and 1½" (3.8cm) drain line must be supplied• ½" (1.3cm) industrial-grade flexible hoses with ¾" (1.9cm)
female hose fittings are supplied for connection to water supply lines
• 1½" (3.8cm) I.D. reinforced flexible hose is provided for connection to facility drain line
CertificationsUL/cUL (110-120V units only)
Included with product
Description Order Number
Work surface height within range of 33 to 41" (83.8 to 104.1cm); 36" (91.4cm) on fixed-height units unless customer-specified otherwise with order
—
Downdraft ventilation —
Ventilated base cabinet —
Removable sink —
Cold/hot water faucet with foot pedal controls —
Manifold rinse with manual control —
Hand spray —
Duplex GFCI electrical receptacle —
Centimeter ruler on front lip of tabletop —
Type 304 stainless steel construction —
Waste formalin collection system with high-level alarm —
Magnetic instrument bar (instruments not included) P104393
Ordering Information
Description Order Number
Fixed-height 110-120V, 60Hz, 1 Ph model with right-hand sink and foot pedal controls
Remote exhaust via facility duct and blower (not included)
B21106
Elevating 110-120V, 60Hz, 1Ph model with right-hand sink and foot pedal controls
Remote exhaust via facility duct and blower (not included)
B21107
Elevating and fixed-height units with left-hand sinks, manual controls and/or 220-240V, 50/60Hz, 1 Ph electrical ratings are available upon request.
5
If your facility can supply an exhaust duct and remote blower system that provides an airflow of 550 to 600 cfm (0.260 to .0283 cu. m/s), a ducted unit will best suit your needs. (Facility duct and remote blower by others; no filters.)
Validated Exhaust Specifications
Recommended exhaust airflow volume: 550 - 600cfm (0.260 to .0283 cu. m/s)Pressure loss through unit with standard downdraft: 0.15 - 0.18 in.w.g. (0.37 - 0.45mb)Pressure loss through unit with optional back draft: 0.27-0.33 in.w.g. (0.67 - 0.82 mb)
Average capture velocity with downdraft at 3" above work surface: 72-78 fpm (0.366 - 0.396m/s)
Average capture velocity with back draft at back of work surface: 156-170fpm (0.792-0.864m/s)
Average capture velocity with back draft at front of work surface: 59 - 64fpm (0.300 - 0.325m/s)
Remote Exhaust
Gross-Star™ Pathology Workstation Continued...
Choosing the Exhaust System to Fit Your LabRecirculating ExhaustFor existing labs or labs without facility exhaust, it may be necessary to filter and recirculate the air. Specify a unit with integral blowers and filters.
External ExhaustFor distance that do not exceed 20' (6.1m), you may choose a unit with integral blower and optional filters that may be connected to your facility’s exhaust duct for venting. (Facility duct and remote blower, if required, by others.)
Remote ExhaustIf your facility can supply an exhaust duct and remote blower system that provides an airflow of 550 to 600cfm (0.260 to 0.283 cu.m/s), a ducted unit will best suit your needs. (Facility duct and remote blower by others; no filters.)
Recirculating External* Remote
N/A N/A Recommended exhaust airflow volume: 550 – 600cfm (0.260 – 0.0283cu. m/s)
N/A N/A Pressure loss through unit with downdraft: 0.07 – 0.08 in. w.g.(0.17 – 0.20 cu. mb)
N/A N/A Pressure loss through unit with back draft: 0.19 – 0.23 in. w.g.(0.47 – 0.57 cu. mb)
Average capture velocity with downdraft at 3" above work surface:
30 – 33 fpm(0.152 – 0.168 m/s)
55 – 59 fpm(0.279 – 0.300 m/s)
73 – 80fpm(0.371 – 0.406 m/s)
Average capture velocity with optional back draft at back of work surface:
80 – 84 fpm(0.406 – 0.427 m/s)
125 – 133 fpm(0.635 - 0.676 m/s)
157 – 172 fpm(0.798 - 0.874 m/s)
Average capture velocity with optional back draft at front of work surface:
40 – 44 fpm(0.203 – 0.224 m/s)
45 – 51 fpm(0.229 – 0.259 m/s)
60 – 66 fpm(0.406 – 0.427 m/s)
Average face velocity with optional hood assembly:
50 – 60 fpm(0.254 – 0.305 m/s)
85 – 95 fpm(0.432 – 0.483 m/s)
115 – 125 fpm(0.584 – 0.635 m/s)
Flexible Exhaust Duct Adapter for Elevating Units
It connects to your facility’s exhaust duct system to permit unit height adjustment. This piece ships separately and installs to the top of elevating external and remote exhaust units.
Replacement Filters Order Number
Replacement Filter Set– Includes two formaldehyde-neutralizing (potassium permanganate) filters and two fine-particle filters
9990850
* Data represents units without filters. With Filters, external exhaust capture and face velocities are similar to recirculating data
Validated Exhaust Specifications
Recirculating Exhaust–Use of filters is requiredExternal Exhaust–Use of filters if required for applicationRemote Exhaust–No filters are required
Factory Installed Options• Waste formalin collection system with alarms feature both
audible and visual alarms
Description Order Number
Disposal, ½ hp with rocker switch B2111
Back draft and downdraft fume capture system B21216
Back draft fume capture system (no downdraft) B21114
Fresh formalin dispensing system with foot pedal control and low-level alarm B21116
Task lamp (specify left or right side) B1001405
Type 316 stainless-steel construction Special order
Accessories
Description Order Number
Magnifier for B1001405 task lamp B1001326
Movable dictation recorder rack 10629
Movable requisition rack 105417
Photographic blue polyethylene dissecting board B36115
Shelf for Thermo Scientific Shandon MicroWriter™ Cassette labeler (require order number B10708)
B21215
Splash shield on flexible arm (requires drilling for installation) B21201
Ventilated trash bin (specify left or right side) B21115
6
Superior Functionality• Retractable acrylic side splash shields• Units with elevating or fixed-height work surface are available• Elevating units have a user-adjustable work surface height
from 33.5 to 45.5" (85.1 to 115.6cm)• Fixed-height units have a work surface height that is
factory set to your specification • Deep sink with cold/hot water faucet• ½ hp disposal is standard (please check with local
authorities before ordering a unit with disposal; some areas prohibit the use of disposals)
• Hands-free proximity sensing controls for cold/hot water faucet, built-in table rinse, and disposal
• Abundant light directed to the work surface• Vacuum breaker-protected water supply• Appliances plug directly into the unit for convenient use• Each unit comes complete with an integral centimeter ruler
on front lip of tabletop, magnetic instrument bar and paper towel dispenser
• Built-in end table rinse washes down work surfaces quickly• Optional camera and monitor/keyboard brackets are available• Camera bracket slides along the width of the unit• Monitor bracket is designed to hold a thin flat-screen display
monitor• Programmable microprocessor allows clock time to be
changed and the filter replacement alarm to be reset (on proximity sensing controlled units only)
Three Ventilation System Options• Recirculating exhaust models feature formaldehyde-
neutralizing filters and an integral blower• External exhaust models include an integral blower for
short distances• Remote exhaust models connect to the facility exhaust
system
Superior Quality• Standard Type 304 or optional Type 316 stainless-steel work
surfaces and panels• Extruded aluminum frame is designed to distribute weight
evenly, stand up to heavy use, resist corrosion, add durability and minimize unit weight
• Built tough to stand up to years of extensive work without corrosion
Thermo Scientific Shandon Grosslab Senior Pathology Workstation
Designed for Easy Shipping and Installation• All units ship in two convenient assemblies that fit through a
standard 32" (81.3cm) doorway• The two assemblies link firmly with easy-to-assemble inte-
gral cam latches• Units connect to the facility cold/hot water supplies and
drain• Units are hard wired to the facility electrical system
Physical Specifications• Overall Dimensions (H x W): 81 to 93 x 60"
(205.7 to 236.2 x 152.4cm)• Depth shown below (see Installed Depth from Front of Unit
to Wall)• Work surface height within range of 33.5 to 45.5" (85.1 to
115.6 cm); 36" (91.4cm) on fixed-height units unless customer-specified otherwise with order
• Sink (L x W x D): 14 x 12 x 6" (35.6 x 30.5 x 15.2cm)• Top Piece Weight: Uncrated, 285 lb. (129.3kg); crated, 375
lb. (170.1kg)• Bottom Piece Weight: Uncrated, 475 lb. (215.5kg); crated,
545 lb. (247.2kg)
Electrical Specifications• 110 – 120V, 60Hz, 1Ph• Draw 20 amps and require a separate 15-amp circuit for one
hospital-grade duplex ground fault current interrupter (GFCI) receptacle
Plumbing Specifications• ¾" (1.9cm) hot and cold water supply lines with shutoff
valves and 1½" (3.8cm) drain line must be supplied• ½" (1.3cm) industrial-grade flexible hoses with ¾" (1.9cm)
female hose fittings are supplied for connection to water supply lines
• 1½" (3.8cm) I.D. reinforced flexible hose is provided for connection to facility drain line
CertificationsUL/cUL (110-120V units only)
Installed Depth from Front of Unit to Wall• Elevating, recirculating units: 32.5" (82.6cm)• Elevating, external exhaust units: 38" (96.5cm)• Elevating, remote exhaust units: 38" (96.5cm)• Fixed-height, recirculating units: 32.5" (82.6cm)• Fixed-height, external exhaust units: 36.5" (92.7cm)• Fixed-height, remote exhaust units: 36.5" (92.7cm)
Included with product
Description Order Number
Work surface height within range of 33.5 to 45.5" (85.1 to 115.6 cm); 36" (91.4cm) on fixed-height units unless customer-specified otherwise with order
—
Louvered back draft ventilation —
Sink —
Cold/hot water faucet with proximity sensing controls (proximity sensing controlled units only) or manual controls (manually controlled units only)
—
Built-in table rinse with proximity sensing control (proximity sensing controlled units only) or manual control (manually controlled units only)
—
Disposal, 1/2 hp with proximity sensing control (proximity sensing controlled units only) or manual control (manually controlled units only)
—
7
Hand-free proximity sensing controls for cold/hot water faucet, table rinse, and disposal.
Hand spray —
Duplex GFCI Electrical Receptacle —
Centimeter ruler on front lip of tabletop —
Fixed lower shelf —
Fixed upper shelf —
Fluorescent light —
Type 304 stainless-steel tabletop and panels —
Extruded aluminum frame —
Retractable acrylic side splash shields —
Programmable microprocessor for date, time and filter replacement alarm (prox-imity sensing controlled units only)
—
Tea strainer faucet with manual control, bracket and tea strainer —
Magnifier on flexible arm 104404
Magnetic instrument bar (instruments not included) P104393
Towel dispenser for C-fold towels 1070214
C-fold towels 104401
Ordering Information
Description Order NumberElevating 110-120V, 60Hz, 1Ph models with right-hand sink and proximity sensing controls
Recirculating Exhaust via filters and integral blower
9700
External Exhaust via integral blower and facility duct (20' max.; not included)
97001
Remote Exhaust via facility duct and blower (not included)
97002
Fixed-height 110-120V, 60Hz, 1Ph models with right-hand sink and proximity sensing controls.
Recirculating Exhaust via filters and integral blower
97003
External Exhaust via integral blower and facility duct (20' max.; not included)
97004
Remote Exhaust via facility duct and blower (not included)
97005
Elevating 110-120V, 60Hz, 1Ph models with right-hand sink and manual controls
Recirculating Exhaust via filters and integral blower
97006
External Exhaust via integral blower and facility duct (20' max.; not included)
97007
Remote Exhaust via facility duct and blower (not included)
97008
Fixed-height 110-120V, 60Hz, 1Ph models with right-hand sink and manual controls
Recirculating Exhaust via filters and integral blower
97009
External Exhaust via integral blower and facility duct (20' max.; not included)
970010
Remote Exhaust via facility duct and blower (not included)
970011
Elevating and fixed-height units with left-hand sinks, foot pedal controls and/or 220-240V, 50/60Hz 1Ph electrical rating are available upon request.
Factory Installed Options
Description Order Number
Task lamp (specify left or right side) B1005102
Type 316 stainless-steel construction Special order
Accessories
Description Order Number
Camera bracket 10661
Fresh formalin dispensing carboy 104395
Magnifier for B1005102 task lamp B1001326
Movable dictation recorder rack 10629
Movable requisition rack 105417
Photographic blue polyethylene dissecting board B36115
Shelf for Thermo Scientific Shandon MicroWriter™ Cassette labeler (requires order number B10708)
B21229
Splash shield on flexible arm (requires drilling for installation) B21201
Thin monitor/keyboard bracket B10708
Ventilated trash bin (specify left or right side)
B21115
Choosing the Exhaust System to Fit Your LabRecirculating ExhaustFor existing labs or labs without facility exhaust, it may be neces-sary to filter and recirculate the air. Specify a unit with integral blowers and filters.
External ExhaustFor distances that do not exceed 20' (6.1m), you may choose a unit with integral blower and optional filters that may be con-nected to your facility’s exhaust duct for venting. (Facility duct and remote blower, if required, by others.)
Remote ExhaustIf your facility can supply an exhaust duct and remote blower system that provides an airflow of 500cfm (0.236 cu.m/s), a ducted unit will best suit your needs. (Facility duct and remote blower by others; no filters.)
Validated Exhaust Specifications
Recirculating External Remote
N/A N/A Recommended exhaust airflow volume: 500 cfm (0.236 cu. m/s)
N/A N/A Pressure loss through unit: 0.41 in. w.g. (1.02 mb)
Average capture velocity at vented area with side panels:
89 fpm (0.452 m/s)
106 fpm Without(0.538 m/s) Filters
128 fpm(650 m/s)
Fro 80 fpm With(0.406 m/s) Filters
Average capture velocity at front of unit with side panels:
38 fpm(0.193 m/s)
55 fpm Without (0.279 m/s) Filters
22 fpm With(0.112 m/s) Filters
69 fpm(0.351 m/s)
Recirculating Exhaust – Use of filters is requiredExternal Exhaust – Use filters if required for applicationRemote Exhaust – No filters are required
Replacement Filters Order Number
Replacement Filter Set – Includes two formaldehyde-neutralizing (potassium permanganate) filters and two fine-particle filters
9990850
Units have 6" (15.2cm) deep sinks, tea strainer and separate faucet for rinsing curettings and other small specimens.
Table rinse comes standard.
Flexible exhaust duct adapter for elevating units ships separately and installs to the back of elevating external and remote exhaust units. It con-nects to your facility’s exhaust duct system, permitting the unit to elevate.
8
Features• Rapid positive drainage• Quick and easy installation• Three ventilation system options: recirculating exhaust,
external exhaust, or remote exhaust• Back draft ventilation for efficient and quiet fumes capture
across work surface• Ergonomically designed to be low to the counter• Use with optional stand (10456) to free up counter space• Programmable microprocessor allows clock time to be
changed and the filter replacement alarm to be reset• Optional splash shield (B21201) protects the user while
dissecting specimens• Flat stainless-steel work surface include three removable
perforated grid plates• Abundant fluorescent light is directed to the work surface• Vacuum breaker-protected water supply• Hands-free proximity sensing control for cold water faucet;
also has manual override capability• Appliances plug directly into the unit for convenient use• Each unit comes with an integral centimeter ruler on the
front lip of the tabletop, magnetic instrument bar and towel dispenser
• Standard Type 304 or optional Type 316 stainless-steel construction
Physical Specifications• Overall Dimensions (H x W x D): Recirculating Exhaust: 45.75 x 48 x 28"
(116.2 x 121.9 x 71.1cm) External Exhaust: 52.75 x 48 x 28" (134 x 121.9 x 71.1cm) Remote Exhaust: 52.75 x 48 x 28" (134 x 121.9 x 71.1cm)• Work Surface Height: 1.75" (4.4cm) above benchtop• Recommended Depth: 29" (73.7cm) from front of unit to wall• Sink (W x L x D): 18 x 6 x 4" (45.7 x 15.2 x 10.2cm)• Weight: Uncrated, 300 lb. (136.1kg); crated, 350 lb. (158.8kg)
Electrical Specifications• 110-120V, 60Hz, 1Ph• One IEC 320 power entry module and one point-of-use
power cord are supplied• Facility electrical receptacle with 15 amp circuit is required
for use with power cord• Draw 15 amps including the two hospital-grade duplex
ground fault circuit interrupter (GFCI) receptacles
Plumbing Specifications
Thermo Scientific Shandon GrosslabJunior Benchtop Workstation
• One ½" (1.3cm) industrial-grade flexible hose with ¾" (1.9cm) female hose fitting is supplied for connection to the facility cold water supply line
• One ¾" (1.9cm) NPT connection and 1" (2.5cm) I.D. reinforced flexible hose is supplied for connection to the facility drain line
CertificationsUL/cUL (110-120V units only)
Included With Product
Description Order Number
Work surface height 1.75" (4.4cm) above benchtop —
Louvered back draft ventilation —
Centered sink on lower shelf —
Cold water faucet with rocker switch for user choice of proximity sensing or manual control
—
Deluxe hand spray —
Two duplex GFCI electrical receptacles —
Centimeter ruler on front lip of tabletop —
Fixed lower shelf —
Fixed upper shelf —
Fluorescent light —
Type 304 stainless-steel construction —
Programmable microprocessor for date, time and filter —
Magnetic instrument bar (instruments not included) P104393
Towel dispenser for C-fold towels 1070214
C-fold towels 104401
Ordering Information
Description Order NumberBenchtop 110-120V, 60Hz, 1Ph models with proximity sensing/manual override controls for cold water faucet
Recirculating Exhaust via filters and integral blower
9600
External Exhaust via integral blower and facility duct (20' max.; not included)
96001
Remote Exhaust via facility duct and blower (not included)
96002
Benchtop units with 220-240V, 50/60Hz, 1Ph electrical ratings available upon request.
Factory Installed Options
Description Order Number
Type 316 stainless-steel construction Special order
9
Accessories• Stand with extruded aluminum frame and stainless-steel
shelf with back panel (stand is height adjustable from 28 to 42" (71 to 107cm) during installation)
Description Order Number
Fluorescent magnifier lamp 1001755
Fresh formalin dispensing carboy 104395
Movable dictation recorder rack 10629
Movable requisition rack 105417
Movable tea strainer bracket and tea strainer (for use with sink and water faucet)
B21237
Photographic blue polyethylene dissecting board B36115
Splash shield on flexible arm (requires drilling for installation) B21201
Stand with extruded aluminum frame, stainless-steel shelf and adjustable height from 28 to 42" (71.1 to 106.7cm)
10456
Optional Stand (10456) transforms the benchtop unit into a stand-alone workstation. Sturdy, extruded aluminum frame with stainless-steel shelf can be height adjusted from 28 to 42" (71.1 to 106.7cm)
Choosing the Exhaust System to Fit Your Lab
Recirculating ExhaustFor existing labs or labs without facility exhaust, it may be neces-sary to filter and recirculate the air. Specify a unit with integral blowers and filters.
External ExhaustFor distances that do not exceed 20' (6.1m), you may choose a unit with integral blower and optional filters that may be connect-ed to your facility’s duct for venting. (Facility duct and remote blower, if required, by others.)
Remote Exhaust If your facility can supply an exhaust duct and remote blower system that provides an airflow of 400cfm (0.189 cu. m/s), a ducted unit will best suit your needs. (Facility duct and remote blower, no filters).
Validated Exhaust Specifications
Recirculating External Remote
N/A N/A
Recommended exhaust airflow volume: 400 cfm (0.189cu. m/s)
N/A N/APressure loss through unit: 1.15 in. w.g. (2.87 mb)
Average capture velocity at vented area:
119 –121fpm (0.604 – 0.615 m/s)
122–123 fpm (0.620 – 0.625 m/s)
148 fpm (0.752 m/s)
Average capture velocity at front of unit:
10 fpm (0.051m/s) 10–13 fpm (0.051– 0.066 m/s)
15 fpm (0.076 m/s)
Recirculating Exhaust – Use of filters is requiredExternal Exhaust – Use filters if required for applicationRemote Exhaust – No filters are required
Replacement Filters Order Number
Replacement Filter Set– Includes two formaldehyde-neutralizing (potassium permanganate) filters and two fine-particle filters
1001618
To minimize contamination and maximize convenience, Grosslab Junior Benchtop units feature a hands-free proximity sensing control for cold water.
Filter drawers are located in the front of the unit for easy access.
An optional magnifier lamp mounts on the side of the unit for added convenience in dis-secting delicate specimens.
10
Thermo Scientific Shandon Grosslab Junior Stand-Alone Workstation
Features• Rapid positive drainage• Quick and easy installation• Three ventilation system options: recirculating exhaust,
external exhaust, or remote exhaust• Back draft ventilation for efficient and quiet fumes capture
across work surface• Programmable microprocessor allows clock time to be
changed and the filter replacement alarm to be reset• Optional splash shield (B21201) protects the user while
dissecting specimens• Abundant fluorescent light is directed to the work surface• Vacuum breaker-protected water supply• Appliances plug directly into the unit for convenient use• Each unit comes with an integral centimeter ruler on the
front lip of the tabletop, magnetic instrument bar, and towel dispenser
• Standard Type 304 or optional Type 316 stainless-steel construction
Physical Specifications• Overall Dimensions (H x W x D)
Recirculating exhaust: 78.5 x 48 x 28" (199.4 x 121.9 x 71.1cm)External exhaust: 85.5 x 48 x 28" (217.2 x 121.9 x 71.1cm)Remote exhaust: 85.5 x 48 x 28" (217.2 x 121.9 x 71.1cm)
• Work Surface Height: 36" (91.4cm)• Sink (L x W x D): 14 x 129.75" (35.6 x 30.5 x 24.8cm) • Weight: Uncrated, 500lb. (226.8kg); crated, 600lb, (272.2kg)
Electrical Specifications• 110-120V, 60Hz, 1Ph• Two IEC 320 power entry modules and two point-of-use
power cords are supplied• Facility electrical receptacles with 15 amp circuits are
required for use with each power cord• Draw 15 amp including the two hospital-grade duplex
ground fault circuit interrupter (GFCI) receptacles
Plumbing Specifications• Two ½" (1.3cm) industrial-grade flexible hoses with ¾"
(1.9cm) female hose fittings are supplied for connection to the facility cold and hot water supply line
• 1½" (3.8cm) I.D. reinforced flexible hose is supplied for connection to the facility drain line
Certifications• UL/cUL (110-120V units only)
Included with Product
Description Order Number
Work surface height: 36" (91.4cm) —
Louvered back draft ventilation —
Sink —
Cold/hot water faucet with manual control —
Disposal, ½ hp with manual control —
Hand spray combined with cold/hot water faucet —
Two duplex GFCI electrical receptacles —
Centimeter ruler on front lip of tabletop —
Fixed lower shelf —
Fixed upper shelf —
Fluorescent light —
Type 304 stainless-steel construction —
Programmable microprocessor for date, time and filter —
Magnetic instrument bar (instruments not included) P104393
Towel dispenser for C-fold towels 1070214
C-fold towels 104401
Ordering Information
Description Order Number
Stand-Alone 110-120V, 60Hz, 1Ph models with right-hand sink and manual controls
Recirculating Exhaust via filters and integral blower
96003
External exhaust via integral blower and facility duct (20' max.; not included)
96004
Remote exhaust via facility duct and blower (not included)
96005
Stand-Alone units with left-hand sinks, foot pedal controls and/or 220-240V, 50/60Hz, 1Ph electrical ratings are available upon request.
11
Choosing the Exhaust System to Fit Your Lab
Recirculating ExhaustFor existing labs or labs without facility exhaust, it may be necessary to filter and recirculate the air. Specify a unit with integral blowers and filters.
External ExhaustFor distances that do not exceed 20' (6.1m), you may choose a unit with integral blower and optional filters that may be connected to your facility’s duct for venting. (Facility duct and remote blower, if required, by others.)
Remote Exhaust If your facility can supply an exhaust duct and remote blower system that provides an airflow of 400cfm (0.189 cu. m/s), a ducted unit will best suit your needs. (Facility duct and remote blower, no filters.)
Validated Exhaust Specifications
Recirculating External Remote
N/A N/A
Recommended exhaust airflow volume: 400 cfm (0.189cu. m/s)
N/A N/APressure loss through unit: 1.15 in. w.g. (2.87 mb)
Average capture velocity at vented area:
119 –121fpm (0.604 – 0.615 m/s)
122–123 fpm (0.620 – 0.625 m/s)
148 fpm (0.752 m/s)
Average capture velocity at front of unit:
10 fpm (0.051m/s) 10–13 fpm (0.051– 0.066 m/s)
15 fpm (0.076 m/s)
Recirculating Exhaust–Use of filters is requiredExternal Exhaust–Use of filters is required for applicationRemote Exhaust–No filters are required
Replacement Filters Order Number
Replacement Filter Set – Includes two formaldehyde-neutralizing (potassium permanganate) filters and two fine-particle filters
1001618
The Grosslab Junior Stand-Alone models feature a hand spray combined with the faucet.
Factory Installed Options
Description Order Number
Type 316 stainless-steel construction Special order
Accessories
Description Order Number
Fluorescent magnifier lamp 1001755
Fresh formalin dispensing carboy 104395
Movable tea strainer bracket and tea stainer (for use with sink and water faucet)
B21247
Movable dictation recorder rack 10629
Movable requisition rack 105417
Photographic blue polyethylene dissecting board
B36115
Splash shield on flexible arm (requires drilling for installation)
B21201
Ventilated trash bin (specify left or right side)
B21115
© 2009 Thermo Fisher Scientific Inc. All rights reserved. Suresorb is a trademark of National Nonwovens. All other trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries.
Thermo Scientific Grossing Consumables
Biopsy Bags
• Allow unrestricted fluid movement around tissue. • Reduce risk of small specimen loss.• Reduce reagent carry-over and pressure artifact
often found with sponges.• Peel-open bag conveniently exposes specimen
for rapid removal• Acid resistant biopsy bags feature all the benefits
of nylon biopsy bags, plus offer acid-resistance for decalcification.
• Small Biopsy Bags measure 1.2" x 1.7" (31 x 43 mm)
• Medium Biopsy Bags measure 1.8" x 2.6" (45 x 65 mm)
• Large Biopsy Bags measure 3" x 3.5" (75 x 85 mm)
Dissecting Instruments with Case • Kit is available with complete set of instruments. • Case is also available without instruments.• Photograph may not represent actual set of instru-
ments included with order number 9996969 (kit is subject to change without notice).
Polyethylene Dissecting BoardsWill not dull fine surgical cutting edges.
• Durable, easy-to-clean 0.75" (1.9cm) thick polyethylene will not dull fine surgical cutting edges.
• White opaque surface provides an excellent back-ground for cutting surgical or research specimens.
• Photographic blue surface allows specimens to be photographed directly on the board; no need for removal to another location.
• Large board measures (L x W x H) 16 x 23 x 0.75" (40.6 x 58.4 x 1.9cm)
• Small board measures (L x W x H) 12 x 16 x 0.75" (40.6 x 58.4 x 1.9cm)
Thermo Scientific Grossing Accessories
Description Size Order Number
Instrument case (Does not include instruments)
12.75 x 9.5 x 2.5" (32.4 x 24.1 x 6.4 cm) 1001382
Instrument case with instruments
12.75 x 9.5 x 2.5" (32.4 x 24.1 x 6.4 cm) 9996969
See products catalog for complete list of dissecting instruments
Description Order Number
WhiteLarge BoardSmall Board
36114361191
Photographic BlueLarge BoardSmall Board
B36115B361192
Description Pkg/Qty Order Number
Nylon Biopsy Bags, Small 1,000/pk 6774010
Nylon Biopsy Bags, Medium 1,000/pk 6774009
Nylon Biopsy Bags, Large 500/pk 6774011
Acid-Resistant Biopsy Bags, Small 250/pk 6774051
Acid-Resistant Biopsy Bags, Medium 250/pk 6774050
Acid-Resistant Biopsy Bags, Large 250/pk 6774052
Shandon TBD-1 Decalcifier Rapid hydrochloric acid decalcifier for processing bone marrow biopsies in as little as 15-30 min.• Thin pieces of dense bone process in 3-12 hrs.• Permits utilization of routine end point tests, such as
calcium oxalate• Added ingredients protect cells from actions of acids.
Size Qty Order Number
1 L (0.26 gal) 2/cs. 6764001
1 L (0.26 gal) 4/cs. 6764002
Shandon TBD-2 Decalcifier Formic acid decalcifier for gentle, longer-term processing.
• Go up to 48 hrs. past end point without damaging specimens.
• Permits utilization of routine end point tests, such as calcium oxalate.
• Added ingredients protect cells from action of acid.
Description Pkg/Qty Order Number
1 L (0.26 gal) 2/cs. 6764003
1 L (0.26 gal) 4/cs. 6764004
Suresorb® Clinical Pads and Formalin Neutral-izer PadsIdeal for containment and disposal of body fluids containing Hepatitis B virus, AIDS/HIV and other known pathogens.
• Patented fiber absorbs and then locks in liquids so work area stays drier. • Resists tearing, even when saturated.• Clinical Pads applications include surgical cutting board pads, dissecting pads,
autopsy table pads, and liners for body traps and cadaver bags.• Formalidehyde Neutralizer Pads reduce exposure by chemically bonding with
formaldehyde, resulting in the encapsulation of vapors–ideal for grossing area and autopsy work.
Description Size Oty. Order No.
Autopsy Table Pad 45 x 80" (114.3 x 203cm) 10/cs. 9833
Dissecting Table Pad 22 x 20" (55.9 x 50.8cm) 50/cs. 9834
Surgical Cutting Board Pad 22 x 20" (59.9 x 50.8cm) 50/cs. 9835
Morgue Trough Pad 18 x 72" (45.7 x 182.8cm) 50/cs. 9836
Morgue Stretcher Pad 24 x 72" (61 x 182.8cm) 50/cs. 9837
Biopsy Sample Pad 8 x 10" (20.3 x 25.4cm) 400/cs.100/cs.
541154111
Formaldehyde Neutralizer Pad
8 x 10" (20.3 x 25.4cm)
16 x 20" (40.6 x 50.8cm)
400/cs.50/cs.
100/cs.25/cs.
5641564115643
56431
4481 Campus Drive www.thermo.com/pathologyAnatomical Pathology (800) 522-7270Kalamazoo, MI 49008
M52005 6/09