therm-l-wrap 66 - is-rayfast...shielding effectiveness in db/m. scale a cco rd i ng to i ec61196-1...
TRANSCRIPT
Therm-L-Wrap™ 66
Product Highlights• Operatingtemperature
from-60ºCto+200ºC(-76ºFto+392ºF)
• Excellentradiantheatprotection
• ExcellentEMIshieldingperformance
• FARPart25.853
• Self-wrappingdesign
• Flexible
• Fluidandchemicalresistant
Therm-L-Wrap™66isaself-wrapping,reflectivesleevedesignedtoprovidethermalprotectionfrombothradiantandconvectiveheat.Composedofawovenfiberglassbasefabricandalaminationofaluminumfoil,theproductcanwith-standconvectiveheatsoaksupto+200ºC(+392°F)andsimultaneouslyprotectcriticalcomponentsfromradiantorreflectedheat.
Theuniquewovenstructureimpartsalevelofflexibilitynotfoundinotherreflec-tiveproducts.Italsoallowstheproducttomaintainacircularprofilewhenflexed.
Theself-wrappingdesignofTherm-L-Wrap66allowsforquickandeasyinstalla-tionwhiletheadditionofaself-sealingadhesivereinforcementallowsforperma-nentclosure.Theadhesivestripactsasabarriertodirtandfluidswhilemaintain-ingthefullintegrityofthefinishedaluminizedsleeve.
Our manufacturing sites are certified ISO 9001, ISO/TS 16949,or AS/EN 9100, and ISO 14001
THERMLWRAP66_01232012
Authorised Distributors: www.is-rayfast.com
[email protected] +44(0) 1793 616700
The information and illustrations given herein are believed to be reliable. Federal-Mogul makes no warranties as to their accuracy or completeness and disclaims any liability in connection with their use. Federal-Mogul’s only obligations are those in the standard term of sale for this product and Federal-Mogul will not be liable for any consequential or other damages arising out of the use or misuse of this product. Users should make their own evaluations to determine the suitability of the product for specific applications.
©2008 Federal-Mogul Systems Protection, manufacturer of Bentley-Harris protection products.
Performance Data – Therm-L-Wrap™ 66
Property Test Method Result
Aging EN6059-302(168hrs.at+200°C) Pass
SaltSpray EN2591-307(96hrs.) Pass
Flammability/SmokeDensity/Toxicity ABD0031&FARPart25,paragraph853 Pass
EMIPerformance
Test Method: TransferimpedenceIEC62153-4-3 Sizetested=13mm Result:70dBat100MHz,R0=15mΩ
Zt (
oh
ms/
m)
Frequency (Hz)
Shie
ldin
g E
ffec
tive
nes
s in
dB
/m. S
cale
Acc
ord
ing
to
IEC
6119
6-1
(Z01
= Z
02 =
50
oh
ms)
Transfer Impedence Measurement1,0E+00
1,0E-01
1,0E-02
-40
-60
-80
1,0E+04 1,0E+05 1,0E+06 1,0E+07 1,0E+08
New
After 96h Salt Spray Test
ThermalPerformance SAEJ2302(HotBox540°C)
147°Creduction(Seegraphbelow)
ResistancetoFluidSpraySynthetichydraulicfluid(Skydrol500B4)Synthetichydraulicfluid(SkydrolLD4)Cleaningfluid(25%propanol+75%whitespirit)
EN6059-303 Remainedstuckafterfluidspray
All numeric data shows average or typical values.
CommercialPart Number
Recommended Application Rangemm (in) Max Weight
g/m (lbs/ft)Min Ø Max Ø
Therm-L-Wrap6610 8(5/16”) 10(3/8”) 32(0.021)
Therm-L-Wrap6613 10(3/8”) 13(1/2”) 54(0.036)
Therm-L-Wrap6616 13(1/2”) 16(5/8”) 58(0.039)
Therm-L-Wrap6619 16(5/8”) 19(3/4”) 68(0.046)
Therm-L-Wrap6625 19(3/4”) 25(1”) 96(0.064)
Product Specifications
Part Numbering SystemExample ProductName Size Color Cutlength Quantity Therm-L-Wrap66 13 Silver 100mm 50pieces
HeatSource
TemperatureBare Mandrel
TemperatureMandrel
Protected withTherm-L-Wrap 66
ThermalEfficiency
600
500
400
300
200
100
0
Thermal Efficiency (Hot Box) SAE J2302Size 13 mm (1/2”) Expressed in °C
Heat source located 25 mm (1”) from the mandrel
Product Available in Straight Cut Lengths Only in 10mm Increments50to500mm +/-5mm
501to1000mm +/-10mm
Authorised Distributors: www.is-rayfast.com