theory of buildings arch243 - v - circulation

35
ABALI TB I 1 horizontal and vertical circulation spaces halls-corridors-stairs

Upload: irfan-meric

Post on 16-Jul-2015

76 views

Category:

Education


0 download

TRANSCRIPT

Page 1: Theory of Buildings ARCH243 - V - Circulation

ABALI TB I 1

horizontal and vertical

circulation spaces

halls-corridors-stairs

Page 2: Theory of Buildings ARCH243 - V - Circulation

ABALI TB I 2

• A space with a main activity is a node.

• All the paths connecting them are

circulation spaces.

Page 3: Theory of Buildings ARCH243 - V - Circulation

ABALI TB I 3

• In public buildings circulation spaces are

specially important.

– Monumental entrance halls,

– Fluid corridors,

– Impressive stair cases....,

Page 4: Theory of Buildings ARCH243 - V - Circulation

ABALI TB I 4

• A university building

entrance hall

Page 5: Theory of Buildings ARCH243 - V - Circulation

ABALI TB I 5

In domestic scale

• for reasons of economy, we try to minimize circulation spaces

• however as “spaces of all users” they deserve to have a quality of its own.

• quality is achieved with ample dimensions and natural light

Page 6: Theory of Buildings ARCH243 - V - Circulation

ABALI TB I 6

• Entrance hall in

domestic scale yet

with ample

dimentions

Page 7: Theory of Buildings ARCH243 - V - Circulation

ABALI TB I 7

• In aparment flats

entrance halls are

minimal in

dimentions and no

natural light at all.

Page 8: Theory of Buildings ARCH243 - V - Circulation

ABALI TB I 8

Same is true for corridors

• Our traditional

homes did not have

corridors

• A gallerie

overlooking to inner

court, a hayat was

the circulation

space.

Page 9: Theory of Buildings ARCH243 - V - Circulation

ABALI TB I 9

• A corridor is by

nature a boring

space,

• It is linear,

monotonous and

usually have no

natural light

Page 10: Theory of Buildings ARCH243 - V - Circulation

ABALI TB I 10

• To over come its negative qualities

– We have to keep circulation spaces at

minimum

– sometimes we overlap a space for certain

activity with circulation (a corridor to bedrooms cutting

through living room)

Page 11: Theory of Buildings ARCH243 - V - Circulation

ABALI TB I 11

a corridor behind the

columns and a gallery

above the columns are

connecting to other

spaces yet it is zone

within main living area

Page 12: Theory of Buildings ARCH243 - V - Circulation

ABALI TB I 12

• if we have to stay in minimum dimensions

than what are the possibilities ?

• usually number of doors opening to the

circulation area determine the size.

Page 13: Theory of Buildings ARCH243 - V - Circulation

ABALI TB I 13

Page 14: Theory of Buildings ARCH243 - V - Circulation

ABALI TB I 14

Page 15: Theory of Buildings ARCH243 - V - Circulation

ABALI TB I 15

cupboards in the rooms or in the corridors are also effective in the size of

the corridor

Page 16: Theory of Buildings ARCH243 - V - Circulation

ABALI TB I 16

in some period of the life span of a dwelling unit one user may be using

wheel chair....

Page 17: Theory of Buildings ARCH243 - V - Circulation

ABALI TB I 17

• it is wise to keep the corridors 110 cm wide

and doors not less than 90 cm for

handicapped use in the long run.

• however, if a staircase is included than the

corridors may have different alternatives.

Page 18: Theory of Buildings ARCH243 - V - Circulation

ABALI TB I 18

Landing at the end of a stair case

Page 19: Theory of Buildings ARCH243 - V - Circulation

ABALI TB I 19

Page 20: Theory of Buildings ARCH243 - V - Circulation

ABALI TB I 20

Page 21: Theory of Buildings ARCH243 - V - Circulation

ABALI TB I 21

stairs

are not only for ascending and

descending

from level to level

Page 22: Theory of Buildings ARCH243 - V - Circulation

ABALI TB I 22

• stairs gives us chance to perceive spaces

from many different views

• stairs create a space of their own

• stairs are circulation areas where 3 rd

dimention is most important.

Page 23: Theory of Buildings ARCH243 - V - Circulation

ABALI TB I 23

Dutch artist

Escher

visualized

the concept

of “Relativity”

as a stair

case

Page 24: Theory of Buildings ARCH243 - V - Circulation

ABALI TB I 24

Dolmabahçe Palace

Page 25: Theory of Buildings ARCH243 - V - Circulation

ABALI TB I 25

• Did you ever

climb to a

minaret ?

• This is stone

masonry

stair

Page 26: Theory of Buildings ARCH243 - V - Circulation

ABALI TB I 26

Snow Palace, Japan

Page 27: Theory of Buildings ARCH243 - V - Circulation

ABALI TB I 27

Louvre

Museum,

Cristal

Pyranid,

Paris

Page 28: Theory of Buildings ARCH243 - V - Circulation

ABALI TB I 28

• These are all monumental scaled stairs, in

domestic scale, we usually use efficient

and minimal stairs

• Therefore, it is vital for architects to make

best use of stair cases.

• To be able to do this, we have to master

technical issues of stairs.

Page 29: Theory of Buildings ARCH243 - V - Circulation

ABALI TB I 29

slope of ramps – stairs - ladders

Page 30: Theory of Buildings ARCH243 - V - Circulation

ABALI TB I 30

• The steepest stair,

ladder

• Only for young and

athletic ....

Page 31: Theory of Buildings ARCH243 - V - Circulation

ABALI TB I 31

• Space under the

stairs have multiple

uses

Page 32: Theory of Buildings ARCH243 - V - Circulation

ABALI TB I 32

slope gives us number of steps, let's say 16 steps

than comes how we arrange them

Page 33: Theory of Buildings ARCH243 - V - Circulation

ABALI TB I 33

note that area they require do not change much

Page 34: Theory of Buildings ARCH243 - V - Circulation

ABALI TB I 34

Page 35: Theory of Buildings ARCH243 - V - Circulation

ABALI TB I 35

stairs in an enclosed shaft (as in fire escape stairs)