the use of a hand-held mid-infrared spectrometer for the rapid prediction of total petroleum...

18
The use of a hand-held mid-infrared spectrometer for the rapid prediction of total petroleum hydrocarbons in soil Water for a Healthy Country Flagship Les J. Janik, José M. Soriano-Disla, Sean T. Forrester, Michael J. McLaughlin, Grant Webster, Richard Stewart 05 December 2013 Infrared workshop, FAO Headquarters (Rome)

Upload: fao

Post on 11-Feb-2017

777 views

Category:

Education


4 download

TRANSCRIPT

Page 1: The use of a hand-held mid-infrared spectrometer for the rapid prediction of total petroleum hydrocarbons in soil Water for a Healthy Country Flagship

The use of a hand-held mid-infrared spectrometer for the rapid prediction of total petroleum hydrocarbons in soil

Water for a Healthy Country Flagship

Les J. Janik, José M. Soriano-Disla, Sean T. Forrester, Michael J. McLaughlin, Grant Webster, Richard Stewart

05 December 2013 Infrared workshop, FAO Headquarters (Rome)

Page 2: The use of a hand-held mid-infrared spectrometer for the rapid prediction of total petroleum hydrocarbons in soil Water for a Healthy Country Flagship

The use of a hand-held mid-infrared spectrometer for the rapid prediction of total petroleum hydrocarbons in soil | Janik et al.

1. Background

2 |

Page 3: The use of a hand-held mid-infrared spectrometer for the rapid prediction of total petroleum hydrocarbons in soil Water for a Healthy Country Flagship

Complex mixture of aliphatic hydrocarbon chains (C10-

C36) derived from crude oil

Major environmental pollutant: spills from production,

storage and distribution

Impacts: soil, sediment, water, biology and humans

Risk assessment and remediation needs to be quick and

is expensive

The use of a hand-held mid-infrared spectrometer for the rapid prediction of total petroleum hydrocarbons in soil | Janik et al.

TPH Background

3 |

Page 4: The use of a hand-held mid-infrared spectrometer for the rapid prediction of total petroleum hydrocarbons in soil Water for a Healthy Country Flagship

Traditional approaches

Laboratory: Supercritical fluid extraction followed by silica clean-up

and gas-chromatography with flame ionization detector (GC-FID)

Field: IR method (ATR) which requires extraction prior measurement

We need a reliable, quick, cheap and “in situ” technique

The use of a hand-held mid-infrared spectrometer for the rapid prediction of total petroleum hydrocarbons in soil | Janik et al.

TPH traditional analysis

4 |

Page 5: The use of a hand-held mid-infrared spectrometer for the rapid prediction of total petroleum hydrocarbons in soil Water for a Healthy Country Flagship

We propose diffuse reflectance mid-infrared spectroscopy together with

partial least squares as an alternative for the “in situ” prediction of TPH (C10-

C36)

Advantages

Rapid

No sample pretreatment

In situ

Multiple analytes prediction

The use of a hand-held mid-infrared spectrometer for the rapid prediction of total petroleum hydrocarbons in soil | Janik et al.

DRIFT-PLSR as an alternative

5 |

Page 6: The use of a hand-held mid-infrared spectrometer for the rapid prediction of total petroleum hydrocarbons in soil Water for a Healthy Country Flagship

The use of a hand-held mid-infrared spectrometer for the rapid prediction of total petroleum hydrocarbons in soil | Janik et al.

Our hand-held spectrometer

6 |

Full FT-IR Hand-held (Agilent)

6000-650 cm-1

15 s scan and 8 cm-1 resolution

~3 kg

Blue-tooth PDA with PLS software

Battery

Page 7: The use of a hand-held mid-infrared spectrometer for the rapid prediction of total petroleum hydrocarbons in soil Water for a Healthy Country Flagship

Mid-infrared sensitive to C-H bonds

The use of a hand-held mid-infrared spectrometer for the rapid prediction of total petroleum hydrocarbons in soil | Janik et al.

TPH peaks

7 |

NIR MIR

NIR (5000-4000 cm-1) and MIR (4000-1200 cm-1) spectra of liquid diesel, crude oil and n-hexane Forrester et al. 2013 (SSSAJ 77, 450-460)

~2730 cm-1 (-CH3)

-CH3

0

0.1

0.2

0.3

0.4

260028003000

Ab

sorb

ance

Wavenumbers

Diesel

SOM

Diesel in clay, and soil organic matter spectra

-CH2

~2950 cm-1 (-CH3) -CH2

Page 8: The use of a hand-held mid-infrared spectrometer for the rapid prediction of total petroleum hydrocarbons in soil Water for a Healthy Country Flagship

The use of a hand-held mid-infrared spectrometer for the rapid prediction of total petroleum hydrocarbons in soil | Janik et al.

The PLSR model

8 |

4540-4120 3000-2600

PCs R2 RMSE RPD PCs R2 RMSE RPD

9 0.84 853 2.4 7 0.92 601 3.4

Selection of optimal spectral range and PLSR development in Forrester et al.

2013 (SSSAJ 77, 450-460)

n = 199 TPH contaminated soils from Australia (0-15,000 mg/kg)

Air-dried

Partial least squares and trained by cross-validation

(2960, 2930, 2850, 2730) (4330, 4260)

Page 9: The use of a hand-held mid-infrared spectrometer for the rapid prediction of total petroleum hydrocarbons in soil Water for a Healthy Country Flagship

The use of a hand-held mid-infrared spectrometer for the rapid prediction of total petroleum hydrocarbons in soil | Janik et al.

Commercialisation of the technique

9 |

2008-2009: collaboration project with Ziltek Pty Ltd (South

Australia)

2012: Method patented in Australia

2013: method patented in USA

2013: Ziltek Pty Ltd. releases the technology as REMSCAN

2013: Publication in SSSAJ describing the patented method

(Forrester et al., 2013)

Page 10: The use of a hand-held mid-infrared spectrometer for the rapid prediction of total petroleum hydrocarbons in soil Water for a Healthy Country Flagship

The use of a hand-held mid-infrared spectrometer for the rapid prediction of total petroleum hydrocarbons in soil | Janik et al.

Challenges

10 |

Presence of moisture: leave the

sample drying, software cut-off

Soil heterogeneity: repeated scans,

mixing the sample

Sample entering into the cone

nose: instrument squared to the

surface and sample tamped flat

1000 2000 3000 4000 5000 Wavenumber (cm-1)

Absorb

ance

TPH

Moist sample

Page 11: The use of a hand-held mid-infrared spectrometer for the rapid prediction of total petroleum hydrocarbons in soil Water for a Healthy Country Flagship

The use of a hand-held mid-infrared spectrometer for the rapid prediction of total petroleum hydrocarbons in soil | Janik et al.

Challenges

11 |

Soil type (TPH spread in sandy soils vs “shielding” effect in clay soils): site

specific or local models. Local models:

Spectral library divided in clusters linked to textural classes

Unknown spectra allocated to the correspondent model

Within each model, 5 TPH range concentrations models: final model

dependent on the TPH value predicted

Page 12: The use of a hand-held mid-infrared spectrometer for the rapid prediction of total petroleum hydrocarbons in soil Water for a Healthy Country Flagship

The use of a hand-held mid-infrared spectrometer for the rapid prediction of total petroleum hydrocarbons in soil | Janik et al.

2. Examples of field uses

12 |

Page 13: The use of a hand-held mid-infrared spectrometer for the rapid prediction of total petroleum hydrocarbons in soil Water for a Healthy Country Flagship

Diesel leaked from a storage

facility and captured in an

emergency bund area

Site specific calibration to quantify

diesel in the bund area and

monitor remediation works

Remediation work completed in 4

days (200 samples/day)

19 ´blind´ samples sent for

analysis

The use of a hand-held mid-infrared spectrometer for the rapid prediction of total petroleum hydrocarbons in soil | Janik et al.

Case study 1: Western Australia

13 |

R2 = 0.997

Page 14: The use of a hand-held mid-infrared spectrometer for the rapid prediction of total petroleum hydrocarbons in soil Water for a Healthy Country Flagship

Ageing power transformer removed. Oil contamination in the footings

RemScan “guided” the remediation work: pit declared “clean” < 1000 mg/kg

The use of a hand-held mid-infrared spectrometer for the rapid prediction of total petroleum hydrocarbons in soil | Janik et al.

Case study 2: South Australia

14 |

Samples from from walls and floor sent to reference laboratory

Reference analysis confirmed TPH predictions

R2 = 0.994

Page 15: The use of a hand-held mid-infrared spectrometer for the rapid prediction of total petroleum hydrocarbons in soil Water for a Healthy Country Flagship

The use of a hand-held mid-infrared spectrometer for the rapid prediction of total petroleum hydrocarbons in soil | Janik et al.

Case study 3: South Australia

15 |

Page 16: The use of a hand-held mid-infrared spectrometer for the rapid prediction of total petroleum hydrocarbons in soil Water for a Healthy Country Flagship

The use of a hand-held mid-infrared spectrometer for the rapid prediction of total petroleum hydrocarbons in soil | Janik et al.

Final remarks

16 |

DRIFT-PLSR using a hand-held spectrometer is suitable technique for the

rapid, cheap and accurate prediction of TPH

RemScan commercialy used

On-going work

Inclusion of new soils in the global calibrations

Inclusion of additional contaminants

Page 17: The use of a hand-held mid-infrared spectrometer for the rapid prediction of total petroleum hydrocarbons in soil Water for a Healthy Country Flagship

• Government of Valencia (Conselleria de Educación) for a Post-

Doctoral Fellowship

• University of Adelaide

• Ziltek Pty Ltd.

The use of a hand-held mid-infrared spectrometer for the rapid prediction of total petroleum hydrocarbons in soil | Janik et al.

Acknowledgements

17 |

Page 18: The use of a hand-held mid-infrared spectrometer for the rapid prediction of total petroleum hydrocarbons in soil Water for a Healthy Country Flagship

Thank you

Sustainable Agriculture Flagship

CSIRO Land and Water (Sustainable Agriculture Flagship)

Jose Martin Soriano Disla (PhD)

t +61883038425

e [email protected]

w www.clw.csiro.au