the synergies of plim, plex, and power uprates: lessons ... · plim, plex, and power uprates:...

31
The Synergies of PLiM, PLEX, and Power Uprates: Lessons Learned From Recent BWR Experience Brian Jordan GE Energy Optimization and Control Nuclear Market Segment Leader Craig Nichols GE-Hitachi Nuclear Energy Manager-Steam Dryer Products

Upload: others

Post on 08-Aug-2020

10 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: The Synergies of PLiM, PLEX, and Power Uprates: Lessons ... · PLiM, PLEX, and Power Uprates: Lessons Learned From Recent BWR Experience Brian Jordan GE Energy Optimization and Control

The Synergies ofPLiM, PLEX, and Power Uprates: Lessons Learned From Recent BWR Experience

Brian JordanGE EnergyOptimization and Control Nuclear Market Segment Leader

Craig NicholsGE-Hitachi Nuclear EnergyManager-Steam Dryer Products

Page 2: The Synergies of PLiM, PLEX, and Power Uprates: Lessons ... · PLiM, PLEX, and Power Uprates: Lessons Learned From Recent BWR Experience Brian Jordan GE Energy Optimization and Control

2GE-Hitachi Nuclear Energy and GE Energy/IAEA-CN-155-022 PLM/ Oct

2007

The Synergies of PLiM, PLEX, and Power Uprates: Lessons Learned From Recent BWR Experience• Business Case• Key Lessons from Implementations

–Vibration–Plant Reliability & Maintenance– Implementation Strategy

• Conclusions

Page 3: The Synergies of PLiM, PLEX, and Power Uprates: Lessons ... · PLiM, PLEX, and Power Uprates: Lessons Learned From Recent BWR Experience Brian Jordan GE Energy Optimization and Control

Business Case – SynergiesOperations

Safety, Capacity Factors, Cost Reduction

Life ExtensionPower Uprates – Extended Power Uprates

Page 4: The Synergies of PLiM, PLEX, and Power Uprates: Lessons ... · PLiM, PLEX, and Power Uprates: Lessons Learned From Recent BWR Experience Brian Jordan GE Energy Optimization and Control

4GE-Hitachi Nuclear Energy and GE Energy/IAEA-CN-155-022 PLM/ Oct

2007 Courtesy of NEI Website

Page 5: The Synergies of PLiM, PLEX, and Power Uprates: Lessons ... · PLiM, PLEX, and Power Uprates: Lessons Learned From Recent BWR Experience Brian Jordan GE Energy Optimization and Control

5GE-Hitachi Nuclear Energy and GE Energy/IAEA-CN-155-022 PLM/ Oct

2007

Courtesy of NEI Website

Page 6: The Synergies of PLiM, PLEX, and Power Uprates: Lessons ... · PLiM, PLEX, and Power Uprates: Lessons Learned From Recent BWR Experience Brian Jordan GE Energy Optimization and Control

6GE-Hitachi Nuclear Energy and GE Energy/IAEA-CN-155-022 PLM/ Oct

2007

Strategic ProjectsPower Uprate> Cost effective additional generation> Economics dictate limits to uprates

– System and component limits can be increased– Analytical limits (technical/licensing approaches)

Plant Life Extension> Regulatory process straight forward> Requires economic planning for equipment life> Many of the same issues as power uprate planning

“In my view, the vast majority of nuclear power plants in the US could be serious candidates for license extension for up to 80 years of operation, and I believe the NRC must prepare itself to consider that question.” – USNRC Commissioner Merrifield

Page 7: The Synergies of PLiM, PLEX, and Power Uprates: Lessons ... · PLiM, PLEX, and Power Uprates: Lessons Learned From Recent BWR Experience Brian Jordan GE Energy Optimization and Control

7GE-Hitachi Nuclear Energy and GE Energy/IAEA-CN-155-022 PLM/ Oct

2007

Why EPU?

Wind IGCC Gas Coal Hydro Nuclear

COE (

cents

/kWh)

Capital O&M FuelEPU

CompetitiveInvestment

• NRC approved 108 uprates since 1977, or• 4,600 additional MWe, or• Equivalent of 4 to 5 reactors

1 EPU =1 150 MW Wind Farm, or

1 Heavy Duty Simple Cycle Gas Turbine, or

1 Small Hydro Facility, or

2 Small Combined Cycles

~

3-4 Year Lead Time

Page 8: The Synergies of PLiM, PLEX, and Power Uprates: Lessons ... · PLiM, PLEX, and Power Uprates: Lessons Learned From Recent BWR Experience Brian Jordan GE Energy Optimization and Control

8GE-Hitachi Nuclear Energy and GE Energy/IAEA-CN-155-022 PLM/ Oct

2007

Courtesy of NEI Website

Page 9: The Synergies of PLiM, PLEX, and Power Uprates: Lessons ... · PLiM, PLEX, and Power Uprates: Lessons Learned From Recent BWR Experience Brian Jordan GE Energy Optimization and Control

9GE-Hitachi Nuclear Energy and GE Energy/IAEA-CN-155-022 PLM/ Oct

2007

BWR / Uprate Schematic• Increased steam flow requires upgrade of key equipment• Balance of plant including turbine/generator modifications and increased fuel cycle costs are all incremental with power level

Page 10: The Synergies of PLiM, PLEX, and Power Uprates: Lessons ... · PLiM, PLEX, and Power Uprates: Lessons Learned From Recent BWR Experience Brian Jordan GE Energy Optimization and Control

Key Lessons from Implementations

Page 11: The Synergies of PLiM, PLEX, and Power Uprates: Lessons ... · PLiM, PLEX, and Power Uprates: Lessons Learned From Recent BWR Experience Brian Jordan GE Energy Optimization and Control

Lesson: VibrationSteam dryer cracking and flow-induced vibration damage on components and supports for the Main steam and Feedwater lines.Actuators for the Electromatic Relief Valves (ERVs) experienced significant fretting and wear.

Page 12: The Synergies of PLiM, PLEX, and Power Uprates: Lessons ... · PLiM, PLEX, and Power Uprates: Lessons Learned From Recent BWR Experience Brian Jordan GE Energy Optimization and Control

12GE-Hitachi Nuclear Energy and GE Energy/IAEA-CN-155-022 PLM/ Oct

2007

Steam Dryer EPU Experience

Event 1 - Lower Cover Plate

Event 2 - Outer Hood

Page 13: The Synergies of PLiM, PLEX, and Power Uprates: Lessons ... · PLiM, PLEX, and Power Uprates: Lessons Learned From Recent BWR Experience Brian Jordan GE Energy Optimization and Control

13GE-Hitachi Nuclear Energy and GE Energy/IAEA-CN-155-022 PLM/ Oct

2007

Current State of Knowledge> Recent Experience - Curved Hood Dryers

– Hydrodynamic loads more consequential– Peak stresses are in internal areas making modifications more difficult

– Current load definition tools do not adequately address in-vessel sources

– USNRC requiring large margin to account for load definition uncertainty

> Replacement can be cost effective option– Reduced outage duration and worker dose offset higher capital cost. Supports life extension

– Improved regulatory certainty

Page 14: The Synergies of PLiM, PLEX, and Power Uprates: Lessons ... · PLiM, PLEX, and Power Uprates: Lessons Learned From Recent BWR Experience Brian Jordan GE Energy Optimization and Control

14GE-Hitachi Nuclear Energy and GE Energy/IAEA-CN-155-022 PLM/ Oct

2007

Dryer Program (NRC RG 1.20)

•Calculation of expected excitation sources •Comprehensive and conservative dryer analysis including uncertainty assessment with a benchmarked model•Evaluation of dryer acoustic and hydrodynamic loads at CLTP with margin for EPU using steam line measurements•Monitoring and evaluation of dryer loads with plant instruments during power ascension with licensed limits•NRC review/acceptance at each stage of power ascension•EPU License Condition for dryer and piping FIV issues•Long term commitment to follow-on inspections

Page 15: The Synergies of PLiM, PLEX, and Power Uprates: Lessons ... · PLiM, PLEX, and Power Uprates: Lessons Learned From Recent BWR Experience Brian Jordan GE Energy Optimization and Control

15GE-Hitachi Nuclear Energy and GE Energy/IAEA-CN-155-022 PLM/ Oct

2007

2.00 200.00Hz10.00

100000000.00

Log

( Pa2 /

Hz)

0.00

1.00

Amplit

ude

F PSD P:0003F PSD P:0003:S

� No plant-specific tuning required…eliminates constant model revisions

� Reduces singularities present in other methods� Solves both in-vessel and MSL loads� Benchmarking with QC2 data complete� LTR expected in 2007

Load Definition -PBLE

Load Mitigation� Addressing MSL and in-vessel sources� Retrofit option for operating plants� Incorporate into new plant /dryer design� Does not impact plant operation/ maintenance

� Scale model testing progressing� Provides plants with options for EPU, LCM, and PLEX

� Available 2008

4 0 0 . 0 0 5 0 0 . 0 0H z0 . 0 0

3 . 0 0

Amplit

ude

Pa

0 . 0 0

1 . 0 0

Amplit

ude

4 5 0 . 0 0 4 7 0 . 0 0

C u r v e X Y ( f r o n t ) R M S4 5 0 . 0 0 0 . 2 2 2 . 0 1 P a4 7 0 . 0 0 0 . 5 54 5 0 . 0 0 0 . 1 6 0 . 8 6 P a4 7 0 . 0 0 0 . 3 84 5 0 . 0 0 0 . 1 6 0 . 8 2 P a4 7 0 . 0 0 0 . 4 3

F A u t o P o w e r F R N T : 1 0 0 3 : + Y B a s e l i n eF A u t o P o w e r F R N T : 1 0 0 3 : + Y L e a d i n g E d g e S p o i l e rF A u t o P o w e r F R N T : 1 0 0 3 : + Y T r a i l i n g E d g e S p o i l e r

Steam Dryer Innovations

Page 16: The Synergies of PLiM, PLEX, and Power Uprates: Lessons ... · PLiM, PLEX, and Power Uprates: Lessons Learned From Recent BWR Experience Brian Jordan GE Energy Optimization and Control

16GE-Hitachi Nuclear Energy and GE Energy/IAEA-CN-155-022 PLM/ Oct

2007

P20- ERV Performance

Modified ActuatorGE modified existing actuator to withstand high frequency

vibration.• Hardened guide posts and guides• More stable guide support assembly centers motion• Dampened input into base• Controlled tolerances on interface parts reduces lateral movement• Engineered springs for consistent load

Damaged Original Actuator Original actuator failed due to excessive wear

• Guide Bushings wore sufficiently to allow springs to slide thru• Guide rods jammed in bushing due to wear• Plunger jammed in solenoid due to loss of alignment• Actuator life was less than 24 months

Electromatic relief valves (ERV)

Page 17: The Synergies of PLiM, PLEX, and Power Uprates: Lessons ... · PLiM, PLEX, and Power Uprates: Lessons Learned From Recent BWR Experience Brian Jordan GE Energy Optimization and Control

Plant Reliabilityand MaintenanceMajority of the problems attributed to EPU are in the Balance-of-Plant (BOP) area and involve pre-EPU plant component deficiencies or minimal operating margins

Page 18: The Synergies of PLiM, PLEX, and Power Uprates: Lessons ... · PLiM, PLEX, and Power Uprates: Lessons Learned From Recent BWR Experience Brian Jordan GE Energy Optimization and Control

18GE-Hitachi Nuclear Energy and GE Energy/IAEA-CN-155-022 PLM/ Oct

2007

GE/Bently Nevada LLC And Management Resources Group Inc. Proprietary

F “Worst New”“Worst New”High infant mortality then random failure

B“Bathtub Curve”“Bathtub Curve” - High infant mortality, then a low level of random failure, then a wear out zone

A “Traditional View”“Traditional View”Random Failure then a wear out zone

C “Slow Aging”“Slow Aging” - Steady increase in the probability of failure

D “Best New”“Best New” - Sharp increase in the probability of failure then random failure

E “Constant Random Failure”“Constant Random Failure”Random - No age related failure pattern

2 %

4 %

5 %

7 %

14 %

68 %

11%11%

89%89%

Failure Patterns

Because 89% of failures are not age related, Condition-Based Maintenance is more effective than relying on Time-Based Maintenance for these failure modes.

Page 19: The Synergies of PLiM, PLEX, and Power Uprates: Lessons ... · PLiM, PLEX, and Power Uprates: Lessons Learned From Recent BWR Experience Brian Jordan GE Energy Optimization and Control

19GE-Hitachi Nuclear Energy and GE Energy/IAEA-CN-155-022 PLM/ Oct

2007

Existing Reliability Considerations…

100% Power

Failure Rate

Time

Infant Mortality

Useful Life

Failure

40 Year Life

Otherwise facing:• Premature failures• Obsolescence• Single Point Vulnerabilities• Unrealized benefits of

operating experience

Page 20: The Synergies of PLiM, PLEX, and Power Uprates: Lessons ... · PLiM, PLEX, and Power Uprates: Lessons Learned From Recent BWR Experience Brian Jordan GE Energy Optimization and Control

20GE-Hitachi Nuclear Energy and GE Energy/IAEA-CN-155-022 PLM/ Oct

2007

Life Extension Reliability Impact

100% Power

40 Year Life

Failure Rate

Time

Infant Mortality

Useful Life

Failure

60 Year Life

License Renewal/Life ExtensionEquipment could fail before extended life…

Page 21: The Synergies of PLiM, PLEX, and Power Uprates: Lessons ... · PLiM, PLEX, and Power Uprates: Lessons Learned From Recent BWR Experience Brian Jordan GE Energy Optimization and Control

21GE-Hitachi Nuclear Energy and GE Energy/IAEA-CN-155-022 PLM/ Oct

2007

Failure Rate

Power Uprate Reliability Impact

100% Power

Time

Infant Mortality

Useful Life

Failure

40 Year Life

120% Power }Extended Power Uprate (EPU)

Failure could accelerate with higher powers…

Page 22: The Synergies of PLiM, PLEX, and Power Uprates: Lessons ... · PLiM, PLEX, and Power Uprates: Lessons Learned From Recent BWR Experience Brian Jordan GE Energy Optimization and Control

22GE-Hitachi Nuclear Energy and GE Energy/IAEA-CN-155-022 PLM/ Oct

2007

Combined PLEX and PU Reliability Impact

40 Year Life

60 Year Life

100% Power

Failure Rate

Time

Infant Mortality

Useful Life

Failure

40 Year Life

120% Power EPUPLEX

Page 23: The Synergies of PLiM, PLEX, and Power Uprates: Lessons ... · PLiM, PLEX, and Power Uprates: Lessons Learned From Recent BWR Experience Brian Jordan GE Energy Optimization and Control

23GE-Hitachi Nuclear Energy and GE Energy/IAEA-CN-155-022 PLM/ Oct

2007

Reliability & Margin Enhancement

40 Year Life

60 Year Life

100% Power

Failure Rate

Time

Infant Mortality

Useful Life

Failure

40 Year Life

120% Power EPUPLEX

Performance 20SM

Page 24: The Synergies of PLiM, PLEX, and Power Uprates: Lessons ... · PLiM, PLEX, and Power Uprates: Lessons Learned From Recent BWR Experience Brian Jordan GE Energy Optimization and Control

24GE-Hitachi Nuclear Energy and GE Energy/IAEA-CN-155-022 PLM/ Oct

2007

Online - continuousmonitoring & protection

3500 & TDI3300 & TDXNetor TDE

Asset Condition Monitoring

Critical assets• Steam Turbines• Compressors• Main line Pumps• Recip Compressors

Essential assets• Fans• Pumps• Blowers• Etc…

BOP assets

Switch/Hub

Online – periodic(scanning) monitoring

Trendmaster Pro

Offline – portableLube oil

Thermography, etc…

Snapshotfor

WindowsCE

Motor ManagementRelays

GE EnergyBently Nevada

Page 25: The Synergies of PLiM, PLEX, and Power Uprates: Lessons ... · PLiM, PLEX, and Power Uprates: Lessons Learned From Recent BWR Experience Brian Jordan GE Energy Optimization and Control

25GE-Hitachi Nuclear Energy and GE Energy/IAEA-CN-155-022 PLM/ Oct

2007

Synergy: PLiM, PLEX, EPUInstrumentation & Control• Power Range Neutron Monitoring (PRNM)• Turbine Control, BOP I&C• Steam Dryer Instrumentation

CONTROLCONTROL PROTECTPROTECT OPTIMIZEOPTIMIZE

Page 26: The Synergies of PLiM, PLEX, and Power Uprates: Lessons ... · PLiM, PLEX, and Power Uprates: Lessons Learned From Recent BWR Experience Brian Jordan GE Energy Optimization and Control

Implementation StrategyPerform a comprehensive pre-EPU assessment of the plant – AS-IS condition with plant owner collaboration

Evaluate plant procedures for all systems and components that may be affected by EPU and revise appropriately prior to implementation of EPUReview Main Steam and Feedwater components for potential vibration and wear related degradationCondition Monitoring and I&C Upgrades as part of evaluation process

Page 27: The Synergies of PLiM, PLEX, and Power Uprates: Lessons ... · PLiM, PLEX, and Power Uprates: Lessons Learned From Recent BWR Experience Brian Jordan GE Energy Optimization and Control

27GE-Hitachi Nuclear Energy and GE Energy/IAEA-CN-155-022 PLM/ Oct

2007

EPU feasibility study = decision making informationEPU Cost Profile

$-

$10.0

$20.0

$30.0

$40.0

$50.0

$60.0

$70.0

$80.0

$90.0

$100.0

$110.0

$120.0

100% 102% 104% 106% 108% 110% 112% 114% 116% 118% 120%Power (%OLTP)

$M

$790/KW

$525/KW

Approximate Values

Baseline ($M):PUSAR MSR/Control Panel Mod MELLLAMisc. Modifications Customer project administration costs

HP Mod

HP Turb, Stator, Cooling

LP Replacement

Chiller Mod

$824/KW

#5 FW Htr $2M

LP Stage 8 Buckets

Cond Demin

LP Stage 9 Buckets

$573/KW

Pinch Point Map Essential for Long Term Equipment Planning

Page 28: The Synergies of PLiM, PLEX, and Power Uprates: Lessons ... · PLiM, PLEX, and Power Uprates: Lessons Learned From Recent BWR Experience Brian Jordan GE Energy Optimization and Control

28GE-Hitachi Nuclear Energy and GE Energy/IAEA-CN-155-022 PLM/ Oct

2007

Recent Examples and ResultsRecent North US BWR – 20% power uprate plus modernization and margin recapture– Uprate capacity factor highest ever – No EPU impacts

MidWest US BWR – Integrated EPU and LCM Plan– Effective replacements vs. marginal modifications

Steam dryer options– Modify, replace, mitigate– Instrumentation as needed

Page 29: The Synergies of PLiM, PLEX, and Power Uprates: Lessons ... · PLiM, PLEX, and Power Uprates: Lessons Learned From Recent BWR Experience Brian Jordan GE Energy Optimization and Control

29GE-Hitachi Nuclear Energy and GE Energy/IAEA-CN-155-022 PLM/ Oct

2007

Plant Performance:� M&D Package� Performance Guarantees� Multi-Year Agreement� Asset Optimization

Optimize3

Point of Arrival

Plant Improvements:� Replace� Repair� Upgrade� Uprate

Solve2

EvaluatePlant Baseline:� Business Strategy � Nuclear Island� Turbine Island� Balance of Plant

1

Fleet • Plant • System • Equipment • Component

Performance 20SM

Synergistic Approach•PliM•PLEX•EPU

Page 30: The Synergies of PLiM, PLEX, and Power Uprates: Lessons ... · PLiM, PLEX, and Power Uprates: Lessons Learned From Recent BWR Experience Brian Jordan GE Energy Optimization and Control

ConclusionsSynergies: Power Uprates, Life Extensions, and Plant Life Maintenance are cost effective means to produce additional RELIABLE MW if planned correctly:- Vibration: Review of Main Steam and Feedwater- Reliability Studies with Actions

Balance of Plant Systems Maintenance and Procedures- Have upgrade plan for BOP and I&C systems, add Condition Monitoring

Do as much prior/coordinated to EPU to minimize risk

Page 31: The Synergies of PLiM, PLEX, and Power Uprates: Lessons ... · PLiM, PLEX, and Power Uprates: Lessons Learned From Recent BWR Experience Brian Jordan GE Energy Optimization and Control

31GE-Hitachi Nuclear Energy and GE Energy/IAEA-CN-155-022 PLM/ Oct

2007

Summary

> Develop a long term strategic plan> Evaluate best sequence of projects> Perform overall study (GE version is Performance

20)> Leverage Best Practice Experience and

Regulatory Guidance> Overall Maintenance Plan and Procedures> Condition Monitoring and Digital I&C Upgrades

Long-term view - Build in increased margins and reliability for additional operating period of 20 to 40 years during plant modernization and uprate activities.