the secure advantage. - medtronic.com · v-loc™ device is the preferred barbed suture because:...
TRANSCRIPT
THE SECURE ADVANTAGE.
V-Loc™ Wound Closure Device vs. Stratafix™* SpiralCompetitive Comparison
V-Loc™ device is the preferred barbed suture because:
The Secure Advantage
1. Based on internal test report #R2295, baseline strength comparison of V-Loc™ device 180 size 2-0 and Stratafix™* Spiral PDO size 2-0. March 2014. P<0.001.
2. Based on internal SI Market Model. September 2018.
Its barb design provides greater security than Stratafix™* Spiral1
It’s the worldwide market-leading barbed suture2
Change in Number of Stratafix™* Spiral Barbs¹
† Same magnification and USP size.
1. Surgical Specialties Corporation 510(k) summary documentation. November 2013.
Original Barb PatternStratafix™* Spiral†
New Barb PatternStratafix™* Spiral† V-Loc™ Device†
.25"
~20 barbs/in.
.25"
~44 barbs/in.
.25"
~44 barbs/in.
Preliminary Benchtop Test
Stratafix™* Spiral vs. V-Loc™ Device: Barb Holding Strength in Subcuticular Porcine Tissue
New Barb Pattern
1. Based on internal test report #R2295, baseline strength comparison of V-Loc™ device 180 size 2-0 and Stratafix™* Spiral PDO size 2-0. March 2014.
Max
imum
Lo
ad (k
gf)
Stratafix™* Spiral PGA-PCL Size 2-0 V-Loc™ 90 Size 2-0 P < .000
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0
Even with the additional barbs, V-Loc™ device demonstrates almost 90% greater security compared with Stratafix™* Spiral.1
Post Benchtop Test Product
∙ V-Loc™ device barb design has better holding strength.1
∙ V-Loc™ device barbs allow the strand to withhold greater force.1
∙ Stratafix™* Spiral barbs peel down the strand when tension is applied.
Stratafix™* Spiral vs. V-Loc™ Device: Barb Holding Force
Stratafix™* Spiral† V-Loc™ Device†
Stratafix™* Spiral PGA-PCL Size 2-0 – post test (60x) V-Loc™ 90 Size 2-0 – post test (60x)
† Same magnification and USP size.
1. Based on internal test report #R2295, baseline strength comparison of V-Loc™ device 180 size 2-0 and Stratafix™* Spiral PDO size 2-0. March 2014.
Difference in Barb Design
†Same magnification and USP size.
Single-angle Cut
∙ High-cut angle produces flimsy barbs and the deeper cut-depth results in the compromise of the strand’s strength
Stratafix™* Spiral† V-Loc™ Device†
Stratafix™*Spiral Barbing Technology V-Loc™ Device
Dual-angle Cut
∙ Lower-cut angle produces barbs with strong anchoring force and the shallow cut-depth preserves the integrity of the strand’s strength
Dual-angle Cut
Cut Depth
Strand Depth
Single-angle Cut
Cut Depth
Strand Depth
© 2019 Medtronic. All rights reserved. Medtronic, Medtronic logo and Further, Together are trademarks of Medtronic. ™* Third party brands are trademarks of their respective owners. All other brands are trademarks of a Medtronic company. 03/2019-US140103(2)-[WF#749212]