the revenue effect of inefficient potable water meters on a water utility co

51
Research The Revenue Effect of Inefficient Potable Water Meters on a Water Utility Co

Upload: aubrey-hall

Post on 22-Dec-2015

215 views

Category:

Documents


0 download

TRANSCRIPT

  • Slide 1
  • The Revenue Effect of Inefficient Potable Water Meters on a Water Utility Co
  • Slide 2
  • For many years, utilities and water professional researchers have been trying to determine the optimum time for meter replacement with no conclusive answer Davis, 2005, p. 3
  • Slide 3
  • Significance of the Study Serve as measurement units and cash registers in any modern water-conscious utility. The majority of water utilities throughout the world provide their customers with water meters to measure their potable water consumption. Inaccurate meters tend to under-register consumption volumes and therefore a water utility should monitor closely customer consumption trends to identify meters that have lost accuracy. The primary purpose: to provide a basis for water user fees for the majority of the utilitys revenue
  • Slide 4
  • Non Revenue Losses are approx 68% Suffers from the inability to recover the full cost of service from consumers, partly due to inadequate tariffs as well as excessive losses and inefficiencies. (Smith, 2011, p. 6). The National Water Commission
  • Slide 5
  • Water production: 24.09 billion Litres Billed volume: 8.18 billion Litres LOSSES 15.91 billion Litres Leaks, Overflows Theft, Acc. Errors Meter Errors Theft, Acc. Errors Meter Errors Physical Apparent
  • Slide 6
  • The Water Company Active Customer base: 334,337 Possessing meters: 277,708 Meter age range: 0-20 years Done some amount of study to categorize the real or physical losses such as systems loss. Has not undertaken a comprehensive study in the levels of apparent loss arising from inefficiencies in measuring the volume of water consumed by its customers. Active Customer base: 334,337 Possessing meters: 277,708 Meter age range: 0-20 years Done some amount of study to categorize the real or physical losses such as systems loss. Has not undertaken a comprehensive study in the levels of apparent loss arising from inefficiencies in measuring the volume of water consumed by its customers.
  • Slide 7
  • Literature Review For many years, utilities and water professional researchers have been trying to determine the optimum time for meter replacement with no conclusive answer. Nominally, most water utilities have used a range of service between 10 and 20 years for meter replacement due to the perception of decreasing meter accuracy with length of service (Davis 2005)
  • Slide 8
  • Literature Review Generally Litterature Review highlights theses problems: The wearing of meter measurement components over time. The accumulation of sediments and scales from lime deposit. Orientation in installation. Impurities in the water (Quality) Inappropriate sizing of meters
  • Slide 9
  • Literature Review While real losses are physical losses and a cost to the water utility, apparent losses are not physical but financial losses. WHY? . because the product was delivered to the customer but not accurately measured. (Julian et al. (2008) (Fantozzi, Criminisi, Fontanazza, Freni, & Lambert,2003)
  • Slide 10
  • Literature Review Significant Study With the age of the meter kept constant at 10 yrs) .substantial decrease in accuracy with increasing cumulative volume appears to be the primary factor that ultimately drives the need for meter replacement. (Davis 2005)
  • Slide 11
  • Problem Statement The volumetric measurement of water consumption by customers of the Water Utility is an issue that requires serious policies and standards. Such policy will involve changing water meters that has outdone their useful life based on established guideline. The level of apparent water loss by meter inaccuracy is not known and therefore the company cannot make decisions based on a cost benefit analysis.
  • Slide 12
  • Purpose of the Study The purpose of this study is to examine the effects of aging meters and their inaccuracies on the revenue of the Water Utility..
  • Slide 13
  • Theoretical Framework Like any machinery, potable water meters lose their efficiency over time. It is estimated that within a six year time span, registration errors (under-registration) due to loss in efficiency ranges from 3-10%. (Farley & Trow, 2003, p.7).
  • Slide 14
  • Meter Types Single Jet Multi Jet Nutating Disc
  • Slide 15
  • ADVANTAGE Good at low flow DISADVANTAGE Affected by suspended solids Larger and heavier than equivalent meters More expensive than equivalent meters https://video.search.yahoo.com/search/video;_ylt=A2KLqIUFzxRTQREA0nP7w8QF;_ylu=X3oDMTBrcXU2aHFlBHNlYwNzZWFyY2gEdnRpZA NWMTQ5?p=multi+jet+water+meter+principle&ei=utf-8&fr=yfp-t-901 Meter Types
  • Slide 16
  • CaCo2 Deposit Meter Accuracy 1/8 inch deposit
  • Slide 17
  • What Pairs are Saying Arregui et al. (2006) therefore indicated that the metering errors at low flow rates are higher than errors at high flow rates. According to Arregui et al. (2006) findings, the metering errors for volumetric meters will only tend to go negative as the age or cumulative flow becomes greater.
  • Slide 18
  • Meter Decay with Cumulative Volume
  • Slide 19
  • Typical Decay Error Curve Adapted from Arregui, Cabrera and Cobacho, 2006, Integrated Water Meter Management, p. 140
  • Slide 20
  • Research Question What is the economic age for the replacement of water meters? What revenue loss is incurred through aged meters?
  • Slide 21
  • Limitations Company does not remove meters for sample testing. Difficult to determine whether it was installed as a new meter or a retrofitted one. Poor data integrity ; difficulty ascertaining the age of the meters
  • Slide 22
  • Instrument Meters were tested using a fixed meter test bench (calibrated to the American Water Works Association (AWWA) standards) Procedure..
  • Slide 23
  • Instrument
  • Slide 24
  • TEST Qmin, Qt and Qmax maximum admissible error narrows from +/- 2 % to +/- 5% Low Flow (Qmin) gal. per minute (gpm) or 59.5 L/hr Transition Flow (Qt) 2 gal. per minute (gpm) or 477 L/hr Maximum Flow (Qmax) 20 gal. per minute (gpm) or 4,542 L/hr
  • Slide 25
  • Research Design Dependent variable (meter accuracy) Independent variable (meter age). Subsequently changed to cumulative volume as a representation of the age of each meter. For this research, the samples for testing was taken from a surface water supply
  • Slide 26
  • Models Tested SR SR2 T10
  • Slide 27
  • RESULTS
  • Slide 28
  • Typical Results from Research Investigation
  • Slide 29
  • Results The overall results of all (131) the meter tested were analyzed using the software, Statistical Programme for Social Science (SPSS). The percentage under registration at each test level along with the cumulative volume for each meter were entered into the SPSS database for processing of the following statistical analyses
  • Slide 30
  • Results Brand Meter Percentage Failure Low Flow Medium Flow High Flow All Brands68.717.5610.69
  • Slide 31
  • Qmin.Qt.Qmax Sensus SR63168 Sensus SR22044 Neptune T10742 TOTAL 902414 Number of Meters that Failed the AWWA Test Standard
  • Slide 32
  • % Under registration range Flow Rate/number of meter QminQtQmax 0-10 30 64102 10-20 17 53 20-30 13 01 30-40 7 10 40-50 3 00 50-60 2 00 60-70 0 00 70-80 2 00 80-90 5 00 90-100 23 00 Number of meters that inaccurately over registered 144610 Failure by percentage range
  • Slide 33
  • SR Test Level Sampl e Size MinimumMaximumMean Standard Deviation Low flow 64 -105.1199.60-58.5442.94 Test Level Sample Size MinimumMaximumMean Standard Deviation Low flow43-100.001.00-29.9037.42 T10 Test Level Sample Size MinimumMaximumMean Standard Deviatio n Low flow24-100.000.50-22.1736.42 SR2
  • Slide 34
  • Descriptives N Minimum error (%) Maximu m error (%) Mean error (%) Standard Deviation Qmin.116-99.999.6-34.988539.7717 Qt. 116 -39.9510.23-1.38794.8535 Qmax. 116 -20.578.24-1.84992.8923 Cumulative volume (L) 116 35,22510,000,0002,365,9932,080,544 Valid N (Listwise) 116
  • Slide 35
  • Correlation Analysis Correlation Coefficient QminQtQmax All meters (131)-0.303**-0.039-0.072 Failed meters removed (83) -0.118-0.010-0.266*
  • Slide 36
  • Correlation Coefficient by Model SR -0.504 after Failed meter removal 0.746 SR2 -0.146 after Failed meter removal -0.593** T10 -0.017 after Failed meter removal -0.017
  • Slide 37
  • SR Model
  • Slide 38
  • SR2 Model
  • Slide 39
  • T10 Model
  • Slide 40
  • Slide 41
  • Number of Meters Within the Company that has Cumulative meter reading exceeding 500,000 litres
  • Slide 42
  • Research Question 1. What is the economic age for the replacement of water meters? NB Meter with lowest recorded cumulative volume failed all three test
  • Slide 43
  • Research Question 1. Cumulative volume rather than age will be the recommendation for determining the replacement From study(81 or 62%) had recorded volumes lying within the 500,000 to 1,000,000 litre range.
  • Slide 44
  • Results Average Cumulative Flow Possible Error of each model SR2,756,760.4422.18% SR21,487,006.42 11.36 % T103,188,524.46 9.58%
  • Slide 45
  • Research Question 1. A conservative recommendation would be to replace meters that has recorded Estimated number of years based on 23,000 litres per month average usage. Model Recommended Cumulative Volume Threshold (litres) Average Annual Usage (litres) Estimated no of Years SR 2,700,000.00 272,760.00 9.90 ->10 SR2 1,500,000.00 272,760.00 5.50 -> 6 T10 3,000,000.00 272,760.00 11.00 ->11
  • Slide 46
  • Research question 2: What revenue loss is incurred through aged meters? There are 2155 meters that has exceeded the 1 million litre mark in their service life. Assuming that all these are SR2s (most dominant in the field).
  • Slide 47
  • Research question 2: What possible revenue loss is incurred through aged meters? 23000 x 2,155 = 49,565,000 Litres/month Estimating an 11.36% loss.The true volume = 1.1136 x 49,565,000 = 55,195,584 Litres Estimated Apparent Loss through meter error= 6,352,193L Estimated Revenue loss at 32cents/litre = $2,032,701.81/mth or $ 24,392,421.66 annually
  • Slide 48
  • Research question 2: ROI Current average replacement cost of a domestic meter is $8,260.00. Average monthly domestic revenue is approximately $7,950.00 ROI for the average customer would be approximately one month
  • Slide 49
  • Conclusion The general results for all three models indicate that all the meters tested were least efficient in their performance at the low flow range. The T10 model is the most reliable The SR model is the least performing meter
  • Slide 50
  • Recommendations Implement a meter replacement policy using cumulative volumetric threshold as the basis for replacement. Further cross sectional studies will be necessary to discover other interesting dynamics such as: CaCo2 levels in each supply zone Research the effects based surface vs undeground supply. Indirect supply via storage tanks that are sucseptable to low flow Consider Investing more in the T10 model
  • Slide 51