the jcss calibration service of vacuum field

2
The JCSS calibration service of vacuum field is RUNNING in Japan!! At June-3-2010, the standard and calibration laboratory of component division in ULAVC was accredited as a JCSS-MRA calibration laboratory (JCSS 0258), the first ISO/IEC 17025 compliant calibration laboratory of vacuum field in Japan. Our technical skill and management system of calibration is confirmed as international quality. We supply high quality, international calibration service. The JCSS Calibration Service of Vacuum Field JCSS is the accreditation symbol of Japan Calibration Service System under the Measurement Law. Standard and calibration laboratory of Component Div. in ULVAC Inc. is accredited by JCSS and authorized through the internationally-accepted MRAs. JCSS 0258 denotes an accreditation number of our laboratory. Calibration Measurement Capability JCSS/MRA calibration service of ULVAC Running JCSS calibration based on ISO/IEC 17025 Standard and calibration laboratory of Component Div. in ULVAC Inc. is JCSS/MRA accredited calibration laboratory in pressure/vacuum field. We calibrate vacuum gauges supplied by ULVAC or other facilities, and issue calibration certificate with a JCSS mark. Features Category Type of Vacuum Gauge Calibration Range CMC (Compliance Level Approximately 95%) Pressure (Vacuum Gauge) Viscosity Vacuum Gauge 0.1mPa to 1mPa 2.0% 1mPa to 10mPa 1.0% 10mPa to 0.1Pa 0.8% 0.1Pa to 1Pa 0.7% Diaphragm Vacuum Gauge 1Pa to 100Pa 1.5% 100Pa to 10kPa 0.6% 10kPa to 133kPa 0.3% Ionization Vacuum Gauge 0.1mPa to 1mPa 5.0% 1mPa to 1Pa 3.0% Thermal Conductivity Gauge 1 Pa to 1kPa 20% Vacuum Gauge Vacuum Gauge

Upload: others

Post on 18-Dec-2021

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: The JCSS Calibration Service of Vacuum Field

The JCSS calibration service of vacuum field is RUNNING in Japan!!

At June-3-2010, the standard and calibration laboratory of component division in ULAVC was accredited as a JCSS-MRA

calibration laboratory (JCSS 0258), the first ISO/IEC 17025 compliant calibration laboratory of vacuum field in Japan.

Our technical skill and management system of calibration is confirmed as international quality. We supply high quality,

international calibration service.

The JCSS Calibration Service of Vacuum Field

JCSS is the accreditation symbol of Japan Calibration Service System under the Measurement Law. Standard and calibration laboratory of Component Div. in ULVAC Inc. is accredited by JCSS and authorized through the internationally-accepted MRAs. JCSS 0258 denotes an accreditation number of our laboratory.

* Calibration Measurement Capability

JCSS/MRA calibration service of ULVACRunning JCSS calibration based on ISO/IEC 17025Standard and calibration laboratory of Component Div. in ULVAC Inc. is JCSS/MRA accredited calibration laboratory in pressure/vacuum field. We calibrate vacuum gauges supplied by ULVAC or other facilities, and issue calibration certificate with a JCSS mark.

Features

Category Type of Vacuum Gauge Calibration Range CMC* (Compliance Level

Approximately 95%)

Pressure (Vacuum Gauge)

Viscosity Vacuum Gauge

0.1mPa to 1mPa 2.0%1mPa to 10mPa 1.0%10mPa to 0.1Pa 0.8%

0.1Pa to 1Pa 0.7%

Diaphragm Vacuum Gauge

1Pa to 100Pa 1.5%100Pa to 10kPa 0.6%10kPa to 133kPa 0.3%

Ionization Vacuum Gauge

0.1mPa to 1mPa 5.0%1mPa to 1Pa 3.0%

Thermal Conductivity Gauge 1 Pa to 1kPa 20%

Vacuum Gauge

Vacuum Gauge

Page 2: The JCSS Calibration Service of Vacuum Field

ULVAC, Inc. Components Division www.ulvac.co.jp/eng

Overseas Sales in Japan TEL +81-467-89-2261

USA : ULVAC Technologies, Inc. TEL +1-978-686-7550 PHILIPPINES : ULVAC SINGAPORE PTE LTD Philippines Branch TEL +63-46-437-7700GERMANY : ULVAC GmbH TEL +49-89-960909-0 VIETNAM : ULVAC SINGAPORE PTE LTD Vietnam Representative Office TEL +84-8-6255-6762CHINA : ULVAC (SHANGHAI) Trading Co.,Ltd. TEL +86-21-6127-6618 INDONESIA : ULVAC SINGAPORE PTE LTD Indonesia Representative Office TEL +62-21-8990-5070TAIWAN : ULVAC TAIWAN, Inc. TEL +886-3-579-5688 THAILAND : ULVAC (THAILAND) LTD TEL +66-2-7388883KOREA : ULVAC KOREA, Ltd. TEL +82-31-683-2922 MALAYSIA : ULVAC MALAYSIA SDN. BHD. TEL +60-3-5121-4700SINGAPORE : ULVAC SINGAPORE PTE LTD TEL +65-6542-2700 INDIA : ULVAC, Inc., India Branch TEL +91-40-27007006

This catalog is subject to change without notice.This catalog is published in order to sell this product in overseas. Please see Japanese catalog when purchasing in Japan. 1837E-1/2014062500TL

The JCSS Calibration Service of Vacuum Field

Country Accreditation Cooperation Country Accreditation

CooperationIreland INAB Italy ACCREDIAItaly COPA England UKASAustria BMWA Netherlands RvAGreece ESYD Switzerland SASSweden SWEDAC Spain ENACthe Czech Repubic CAI Denmark DANAKGermany DAKKS Norway NAFinland FINAS France COFRACBelgium BELAC Poland PCAPortugal IPAC Romania RENARRussia AAC Analitica Korea KOLASHong Kong HKAS Taiwan TAFChina CNAS Japan IAJapanJapan JAB Japan VLACSri Lanka SLAB Slovakia SNASSlovenia SA Turkey TURKAKTunisia TUNAC Pakistan PNACUnited Arab Emirates DAC Israel ISRACEgpypt EGAC Guatemala OGACosta Rica ECA South Africa SANASMalaysia SM Philippines PAOViet Nam BoA India NABLIndonesia KAN Papua New Guinea PNGLASSingapore SAC Thailand BLA-DSSThailand BLQS-DMSc Thailand NSC-ONACThailand DSS Thailand DMScAustralia NATA New Zealand IANZCanada CALA Canada SCCUnited States A2LA United States ACLASSUnited States IAS United States NVLAPUnited States L-A-B United States PJLAUnited States ASCLD/LAB Mexico emaArgentina OAA Brazil CGCRE/INMETROCuba ONARC

ILAC/MRA-signature Accreditation Cooperation (April.2010) APLAC/MRA-signature Accreditation Cooperation (May.2010)

Calibration Certificate

SAMPLESAMPLE

1. What is JCSS (Japan Calibration Service System) ?

Accreditation of the technical quality of testing and calibration laboratoriesJCSS is an accreditation system of the competence of testing and calibration laboratory to the ISO/IEC 17025. NITE/IA Japan (National Institute of Technology and Evaluation/ International Accreditation Japan) inspect the management system, the technical skill and the traceability of calibration standards of calibration laboratories.Our standard and calibration laboratory is registered as a JCSS-MRA calibration laboratory in vacuum field. Technical skill of calibration for our laboratory is confirmed by the National Institute.

2. What is ISO/IEC 17025 ?

International requirement of testing and calibration laboratory (management system and technical skill)

This regulation is an International Standard of general requirements of the competence of the testing and calibration laboratory. This standard require; 1) administration of management system, 2) competence of technical skill of the calibration laboratory. Only the ISO/IEC 17025 competent laboratory can issue traceable calibration certificate.

3. MRA (Mutual Recognition Arrangement)

Border-less reliability of the calibration resultsAs IA Japan signed ILAC and APLAC MRA (Mutual Recognition Arrangement), JCSS is authorized as internationally acceptable system. JCSS-calibration certificate is available around the countries and region of the ILAC and APLAC members. (ILAC: Laboratory Accreditation Cooperation, APLAC: Asia Pacific Laboratory Accreditation Cooperation)Our standard and calibration laboratory is accredited as MRA laboratory by IA Japan.

4. What is JCSS mark? What is JCSS calibration certificate ?

Clear indication of the traceability to the National StandardOnly the accredited calibration laboratory can issue JCSS calibration certificate in a registered range and category. The JCSS mark clearly shows the traceability of the calibration results to the National Standard. Getting the JCSS calibration certificate is the easiest way to get the traceability to the National and International Standard.

National Institute of AdvancedIndustrial Science and Technology

Uncertainty chain

Standard calibration lab. in Components Division of ULVAC

Customer

National standard

Secondary orreference standard

Reference standard(user)