the importance of season in the testing of radon using ... · this powerpoint 2007 template...
TRANSCRIPT
RESEARCH POSTER PRESENTATION DESIGN © 2012
www.PosterPresentations.com
QUICK DESIGN GUIDE (--THIS SECTION DOES NOT PRINT--)
This PowerPoint 2007 template produces a 36x48
inch professional poster. You can use it to create
your research poster and save valuable time placing
titles, subtitles, text, and graphics.
We provide a series of online tutorials that will
guide you through the poster design process and
answer your poster production questions.
To view our template tutorials, go online to
PosterPresentations.com and click on HELP DESK.
When you are ready to print your poster, go online
to PosterPresentations.com.
Need Assistance? Call us at 1.866.649.3004
Object Placeholders
Using the placeholders
To add text, click inside a placeholder on the poster
and type or paste your text. To move a placeholder,
click it once (to select it). Place your cursor on its
frame, and your cursor will change to this symbol
Click once and drag it to a new location where you
can resize it.
Section Header placeholder
Click and drag this preformatted section header
placeholder to the poster area to add another
section header. Use section headers to separate
topics or concepts within your presentation.
Text placeholder
Move this preformatted text placeholder to the
poster to add a new body of text.
Picture placeholder
Move this graphic placeholder onto your poster, size
it first, and then click it to add a picture to the
poster.
Student discounts are available on our Facebook page.
Go to PosterPresentations.com and click on the FB icon.
QUICK TIPS (--THIS SECTION DOES NOT PRINT--)
This PowerPoint template requires basic PowerPoint
(version 2007 or newer) skills. Below is a list of
commonly asked questions specific to this template.
If you are using an older version of PowerPoint some
template features may not work properly.
Template FAQs
Verifying the quality of your graphics
Go to the VIEW menu and click on ZOOM to set your
preferred magnification. This template is at 100%
the size of the final poster. All text and graphics will
be printed at 100% their size. To see what your
poster will look like when printed, set the zoom to
100% and evaluate the quality of all your graphics
before you submit your poster for printing.
Modifying the layout
This template has four different
column layouts. Right-click
your mouse on the background
and click on LAYOUT to see the
layout options. The columns in
the provided layouts are fixed and cannot be moved
but advanced users can modify any layout by going
to VIEW and then SLIDE MASTER.
Importing text and graphics from external sources
TEXT: Paste or type your text into a pre-existing
placeholder or drag in a new placeholder from the
left side of the template. Move it anywhere as
needed.
PHOTOS: Drag in a picture placeholder, size it first,
click in it and insert a photo from the menu.
TABLES: You can copy and paste a table from an
external document onto this poster template. To
adjust the way the text fits within the cells of a
table that has been pasted, right-click on the table,
click FORMAT SHAPE then click on TEXT BOX and
change the INTERNAL MARGIN values to 0.25.
Modifying the color scheme
To change the color scheme of this template go to
the DESIGN menu and click on COLORS. You can
choose from the provided color combinations or
create your own.
© 2013 PosterPresentations.com 2117 Fourth Street , Unit C Berkeley CA 94710 [email protected]
Radon has been identified by the U.S. EPA as the second
leading cause of lung cancer. Radon gas exists naturally at
low levels. When the gas becomes concentrated in living
spaces, a health hazard arises. The most recent radon risk
assessment for Portland, Oregon was performed in 2013.
For the first time the 2013 analysis included long-term and
short-term (3-7 day) tests. Access to this new short-term
radon data allowed for analysis based on season. Season
was defined for the climate of Portland, Oregon as tests
ending: winter (October 1-March 31), summer (June 1-
August 31), and swing (March 1-April 31 and September 1-
30). A total of 14,873 indoor residential structure readings
were analyzed, defining 66 zip codes with one or more
seasonal radon potentials. Both overall and within season
zip code radon data were examined for maximum radon
reading, average radon reading, and percent greater than 4
pCi/l, which combine to determine the radon potential.
Statistical t-tests were also performed to determine
significance. Based on the analysis of all seasonal short-
term radon testing, winter tests result in statistically
significantly higher readings than tests in summer or swing
months. No significant difference was found in tests
between summer and swing months. Winter short-term
radon potential most closely parallels overall short-term
radon potential for individual zip codes (89% agreement).
Short-term tests are not good indicators of long-term test
results (<66% agreement). If a short-term test is necessary,
a winter season test is suitable. These data support
current EPA guidelines regarding radon testing.
Abstract
• Radon-222 is a colorless, odorless, naturally
occurring gas
• Radon has been know to be a health hazard
since 1984
• Radon gas is the second leading cause of lung
cancer overall and the leading cause of lung
cancer among non-smokers
• Radon-222 gas comes from the radioactive
decay of uranium-238 and is the only gaseous
daughter product
• Radon-222 has a half-life of 3.8 days
• Average outdoor radon level is 0.4 pCi/l
• Average indoor radon level is 1.3 pCi/l
• The U.S. EPA has defined the action level for
indoor radon at 4.0 pCi/l
• The U.S. EPA estimates 1 in 15 residential
structures in the country has high radon levels
• Studies of the Portland, Oregon Metro area
have estimated as high as 1 in 3 residences
having high radon levels
Radon Facts
Results
Figure 4: Potential Comparison- Overall Short Term vs. Winter Season
Of the 62 winter zip code potentials 55 are the same as Linde et al. 2013 overall zip code radon
potentials (89%).
Figure 1: Radon Potential-Summer (1 June-31 Aug) Tests 2861, Max 689.6 pCi/l, Average
3.8 pCi/l, %>4 pCi/l 26%. A total of 45 zip codes were categorized:
High n=13 (29%),Moderate n=27 (60%), Low n=5 (11%)
Methods Season was defined by the climate of the Portland Metro area Winter Season was defined as all short-term tests ending between 1 October-31 March Summer Season was defined as all short-term tests ending between 1 June-31 August Swing Season was defined as all short-term tests ending between 1 April-31 May and 1-31 September
Radon Potential
*If a season within a zip code had less than ten records available, the risk potential was left uncategorized for that season.
T-tests
Datasets were determined to be significantly different if the number of tests
within the set was ten or greater and significance was 0.05 or less (95%
confidence). T-tests were performed for overall season significance as well
as within each zip code.
Conclusions
• Winter has significantly higher indoor radon
readings than both Summer and Swing (Figures 1-3).
• Summer indoor radon readings are not significantly
different from Swing (Figure 1-2).
• Season of testing for indoor radon is a significant
factor in the result of the test.
• Winter season short-term tests are a good analogue
for the overall radon potential for an individual zip
code (Figure 4).
• Long-term radon potential was not closely paralleled
by any season which indicated that long-term tests
should still be favored to produce the most accurate
radon reading (Figure 5).
• Due to highly variable geology, soil properties, and
construction types, every residential structure should
be tested for radon (Figures 6-7).
• When a residential structure is tested (long-term or
short-term) as much as possible of the winter season
for the area should be included.
• The definition of seasons will vary from location to
location due to climate. References
EPA, 2009, Home Buyer's and Seller's Guide to Radon:
http://www.epa.gov/radon/pubs/hmbyguid.html#5.a. (November 26, 2012)
Hemple, S., and Burns, S., 2003, Indoor Radon Values for the Portland, Oregon Area: Portland,
Oregon, Portland State University, Department of Geology.
Linde, T., Lindsey, K., Whitney, H., Icefire, S., Theisen, D., and Burns, S., 2013, A comparison
of geology to radon test data in Portland, Oregon, Oregon Academy of Science, Willamette
University, vol 72 p.48.
Lindsey, K., and Burns, S., 2013 Radon values for Oregon, Oregon Academy of Science,
Willamette University, vol 72 p. 49.
Oregon Climate Service, 2013, Oregon Climate: http://www.ocs.orst.edu/climate-of-oregon (June
20, 2013)
Surgeon General, 2005, Surgeon General Releases National Health Advisory on Radon:
http://www.surgeongeneral.gov/news/2005/01/sg01132005.html (November 20, 2012).
Whitney, H., Lindsey, K., Linde, T., Theisen, D., Icefire, S., Burns, S., 2013 Radon in homes of the
Portland, Oregon area: Radon data from local radon testing companies collected by CRM
(Continuous Radon Measurement) machines, Oregon Academy of Science, Willamette
University, vol. 72, p. 51.
1Portland State University, Oregon, USA Selicity Icefire1, Tamara Linde1, Scott Burns1
The Importance of Season in the Testing of Radon using Short-Term tests in Residential Structures, Portland, Oregon
Figure 7: Underlying major bedrock deposits and faults of the Portland Metro area Figure 6: Locations of coarse and fine-grained flood deposits
Figure 5: Potential Comparison- Overall Long-Term vs. All Seasons
Of the 74 long-term zip code potentials from Linde et al. 2013 only 15 zip code radon potentials are
continuous through all three seasons and long-term tests (20%).
Figure 3: Radon Potential-Winter (1 Oct-31Mar) Tests 7967, Max 976.2 pCi/l, Average 4.8 pCi/l,
%>4 pCi/l 35%. A total of 62 zip codes were categorized:
High n=19 (31%),Moderate n=34 (55%), Low n=7 (11%)
Figure 2: Radon Potential-Swing (1 Apr-31 May and 1-31 Sept) Tests 4045, Max 110.4 pCi/l, Average 4.0 pCi/l, %>4 pCi/l 31%. A total of 56 zip codes were categorized:
High n=16 (29%),Moderate n=28 (50%), Low n=12 (21%)
Max Rank Average Rank %> 4 pCi/l Rank Rank Sum=Potential*
High >10 pCi/l 3 > 4pCi/l 3 >35% 3 9-8
Medium 4-9.9 pCi/l 2 2-4 pCi/l 2 16-35% 2 7-5
Low <4 pCi/l 1 <2 pCi/l 1 <16% 1 4-2