the heat tracing specialists - elmarkdoo.co.rselmarkdoo.co.rs/pdf/katalog_thermon_en.pdf · the...
TRANSCRIPT
Self-Regulating Heating Cables
BSXTM
Freeze Protection andTemperature Maintenance up to 65°C
Maximum Exposure Temperature 85°C
Available Watt Densities .... 9, 15, 25 & 32 W/m @ 10°CSupply Voltage .......................................... 230 Vac Nominal
Freeze Protection andTemperature Maintenance up to 149°C
Maximum Exposure Temperature 250°C Withstands Temperatures Associated With Steam Purging
Available Watt Densities ........ 15, 32, 48 & 64 W/m @ 10°CSupply Voltage ............................................... 230 Vac Nominal
VSXTM
Features:• SemiconductiveSelf-RegulatingHeatingMatrix
• Cut-to-LengthParallelCircuitry
• Nickel-PlatedCopperBusWires
• MetallicBraidsforGroundingPurposes
• PolyolefinorFluoropolymerOverjacket
• WorldwideApprovals
Heat Tracing Systems AccessoriesThermonProvidesaCompleteRangeof:
• Power,SpliceandTerminationKits
• MechanicalThermostats
• ElectronicControlandMonitoringModules
• PowerDistributionandControlPanels
• SystemCommunicationsSoftware
RSXTM
Freeze Protection andTemperature Maintenance up to 65°C
andFoundationHeatingMaximum Exposure Temperature 85°C
Available Watt Densities ....................... 48 W/m @ 10°CSupply Voltage .................................................. 230 Vac Nominal
Freeze Protection andTemperature Maintenance up to 121°C
Maximum Exposure Temperature 121°C
Available Watt Densities ........ 15, 31, 48 & 64 W/m @ 10°CSupply Voltage ............................................... 230 Vac Nominal
KSXTM
HTSXTM
Freeze Protection andTemperature Maintenance up to 121°C
Maximum Exposure Temperature 250°C Withstands Temperatures Associated With Steam Purging
Available Watt Densities .... 9, 18, 27, 37, 48 & 64 W/m @ 10°CSupply Voltage ..................................................... 230 Vac Nominal
Thermon ELECTRIC HEAT TRACING Products
The Heat Tracing Specialists®
Power-Limiting Heating Cables
Freeze Protection andTemperature Maintenance up to 149°C
Maximum Exposure Temperature 260°C
Available Watt Densities ...... 14, 28, 42 & 57 W/m @ 10°CSupply Voltage ............................................ 230 Vac Nominal
HPTTM
Features:• PTCCoiledResistorAlloyHeatingElement
• Cut-to-LengthParallelCircuitry
• Nickel-PlatedCopperBusWires
• MetallicBraidsforGroundingPurposes
• FluoropolymerOverjacket
• WorldwideApprovals
Constant Watt Heating Cables
FP
Freeze Protection andTemperature Maintenance up to 65°C
andFoundationHeating Maximum Exposure Temperature 200°C
Maximum Watt Densities .............. 25 W/m @ 10°CSupply Voltage ....................... 230 and 400 Vac Nominal
Features:• NichromeHeatingElement
• Cut-to-LengthParallelCircuitry
• 3,3mmCopperBusWires
• MetallicBraidsforGroundingPurposes
• FluoropolymerOverjacket
• WorldwideApprovals
Mineral Insulated Heating Cables
Freeze Protection andTemperature Maintenance to 500°C
Maximum Exposure Temperature 600°C
Available Watt Densities .......... Designs up to 260 W/m SupplyVoltage....................................Ratedupto600Vac
MI
Features:• HighTemperatureMagnesiumOxideDielectric
• HighPowerOutputCapabilities
• AvailableinThreeOuter-SheathMaterials
Skin Effect Heating Systems
ThermTracTM
Features:• RuggedHeatTubetoGenerateHeat
• CircuitLengthsupto25Kilometers
• EachSystemFullyFactory-Engineered
Features:• LongCircuitLengthswithFewerPowerPoints
• StabilisedDesignsPossibleUsingThermonSoftware
• MetallicBraidsforEarthingPurposes
LongLineFreezeProtectionand Temperature Maintenance
Maximum Exposure Temperature 260°C
Available Watt Densities ......... Designs up to 25 W/m SupplyVoltage.....................Ratedupto750VacNominal
TESHTM
Series Resistance Heating Cables
PowerOutputs......upto165W/mOperatingVoltages...............upto5KV
Maintenance Temperatures ....... up to 200°CExposure Temperatures .................... up to 260°C
Thermon ELECTRIC HEAT TRACING Products
Electrically Heated Instrument Tubing for Freeze Protection and Temperature MaintenanceTubeTrace® Type SE/ME
Approvedforhazardous(classified)locations.
TubeTrace with BSXTM Self-RegulatingHeatTraceUseforwaterfreezeprotectionandlowtemperaturemaintenance.
Tube Temperature Range: 5°C to 65°CMaximum Exposure Temperature: 85°C
TubeTrace with HTSXTMSelf-RegulatingHeatTraceUsewheretemperatureexposuretosteampurgeisexpected.
Tube Temperature Range: 5°C to 121°CMaximum Exposure Temperature: 250°C
TubeTrace® with VSXTMSelf-RegulatingHeatTraceUsewherehightemperatureexposureisaconsideration.
Tube Temperature Range: 5°C to 149°CMaximum Exposure Temperature: 250°C
TubeTrace® with HPTTMPower-LimitingHeatTraceA“cut-to-length”heattracingforhighertemperaturemaintenance.Alsousedforfreezeprotectionwherehightemperatureexposureisafactor.HPTpower-limitingcablesrepresentthebestchoiceformaintainingtemperaturesupto204°Cthatcanbe“cut-to-length”inthefield.
Tube Temperature Range: 5°C to 204°CMaximum Exposure Temperature: 260°C
Custom CEMS and Analyzer Bundles
Manyanalyzerapplicationshavespecialtytubingrequirements,allofwhich Thermon can provide within our instrument tubing bundles. Examplesoftubematerialsandfinishesthatareavailableinclude:
• Fluoropolymertubing,316and304stainless,weldedorseamless,Monel*, titanium, Inconel * 825, and Alloy 20 are readily available.
• OptionalElectropolished(EP),ChemicalPassivation(CP),andper-formancecoatingssuchasSilcoNert*arealsoavailableonstainlesssteel tubing
• Doublecontainmenttubingormultipletubematerialscanbepro-vided in a common bundle.
“NI” Non-insulated (and non-heated) Bundle Other TubeTrace options can include:
• Auxiliaryconductors
• Unheatedtubes
• Factoryinstalledtemperaturesensor(s)
• Specialmarkingsandidentificationasrequired
* MonelandInconelaretrademarksofIncoAlloysInternational.,Inc.TradenameofSilcoTek™,formerlyadivisionofRestekPerformanceCoatings.SilcoNert™1000replacesSilcosteel®.SilcoNert™2000replacesSulfinert®/Siltek®.
Thermon INSTRUMENT TUBING BUNDLES Products
The Heat Tracing Specialists®
Electrically Heated Instrument Tubing for Freeze Protection of High Temp Steam LinesTubeTrace®TypeSEI/MEI-HT,HTX&HTX2Isolated“cut-to-length”heattraceforhightemperatureexposure,suitablefor ambient sensing control.
TubeTrace® Type SEI/MEI - HTMaintain: 5°CContinuous Exposure: 399°C
TubeTrace® Type SEI/MEI - HTXMaintain: 5°CContinuous Exposure: 593°C
TubeTrace® Type SEI/MEI - HTX2Maintain: 5°CIntermittent Exposure: 593°C
TubeTrace® AccessoriesEverytypeoftubingbundlerequiresproperterminationtoensurereliableperformanceandThermonoffersacompleterangeofterminationkits.BecauseThermonmanufacturestheelectricalheattracingaswell,allofthepowerconnectionandterminationacces-soriesarefullycoordinatedandapproved.
TubeTrace® Type Type SI/MI and SP/MP
Steam Heated Instrument Tubing for Freeze Protection and Temperature Maintenance
Steam or Fluid “Light Traced” (SI/MI)Forfreezeprotectionandlowertemperaturemaintenance.Thetracertubeisisolatedfromtheprocesstube(s),soprocesstubetemperatureswillbesignificantlylowerthanthetracertube temperature.
Tube Temperature Range: 5°C to 121°CMaximum Exposure: 205°C *
Steam or Fluid “Heavy Traced” (SP/MP)Forfreezeprotectionandprocessmaintenance.Thetracertubeisindirectcontactwiththeprocesstube(s),soprocesstubetempera-tures will be very close to the tracer tube temperature.
Standard Tracer Temperature Range: 5°C to 205°CMaximum Exposure: 205°C *
* Higher tube temperatues are possible with XINS-extra insulation HTand HTX type designs.
Thermon INSTRUMENT TUBING BUNDLES Products
SafeTraceTM Provides Increased Safety• SafeTraceTracersComplyWithTestsforSkin
Exposure(perASTMStdC-1005/1057)
• SafetyYellowJacketAlertsPlantPersonneltoPotentially Dangerous Conditions
SafeTraceTM Provides Predictable Heat Transfer• PermitsWinterizationforAnySizePipe
• EliminatesHot/ColdSpotsAssociatedWithBareTubingandSpacerBlocks
• SuitableforTemperature-SensitiveProcesses
Medium Maintain TemperaturesSafeTraceTM BTS: 38°C to 121°C
SnapTraceTM Pre-formedExtrusionInstallation
SLS-IT Isolated Tracing Secured with Fastening Tape
Heat Transfer Compounds to Maintain High Temperatures
Isolated Steam Tracers for Lower Maintain Temperatures
ThermoTube® Type SL Pre-Insulated Tubing• IdeallySuitedtoTransportLiquids,GasesorRefrigerants
• Non-hygroscopicGlassFiberInsulationforEfficiency
• ProtectiveOuterJacketResistsWeatherandMoisture
• ThermoTubeCanbeInstalledinCableTrays,
Angles,Channels,StrutsandonI-Beams
• AllTubingTypesAvailable
Continuous Temperature Range: Service to 205°C *ThermoTube ratings to 593°C also available *.
Steam Supply/Condensate Return Lines
* Higher tube temperatues are possible with XINS-extra insulation HTand HTX type designs.
For steam heated instrument tubing, see Instrument Tubing Bundles.
“Thermonized” with Thermon Heat Transfer Compounds• ConsistentHeatTransferProperties
• LessThan20%ofCostforSteamJacketing
SnapTrace® Preformed Extrusions for Straight PipingAvailable in 1,22 m lengths
• SignificantlyReducesInstallationTime
• NoSurfacePreparationRequired
• UseWithUpto208°CFluid/Steam
Thermon STEAM TRACING Products
T-85“Fillet”Installation
T-3 ChannelTraceTM Installation
HT Compounds for Piping, Valves and Irregular Surfaces(Maximumtemperatureratingsshown)
T-3: 371°C
T-99: 1000°C
T-80: 163°C
T-85: 190°C
T-802: 135°C Two part compound
SafeTraceTM SLS-IT: 24°C to 93°C
SafeTraceTM DLS-IT: 5°C to 54°C
* *ForelectricallyheatedtankapplicationconsiderThermonelectricheatingcables.
The Heat Tracing Specialists®
HeetSheet® Tank and Vessel Heating Units * *• ProvidesPredictableandReliableHeating(orCooling)
• Factory-AppliedNon-hardeningHeatTransferCompoundEnsuresMaximumHeatTransfer
• WafflePatternPermitsMultipleFlowPathsforHeatingandCoolingMedia
• Provides2to3TimestheHeatTransferofPlate-TypeCoils
• NoRiskofCross-ContaminationwithProcess
• Light-weightStainlessSteelConstructionforEasyInstallation
• StainlessSteelInletandOutletTubingProvidedfromFactory
Tank and Vessel Heating
HopperandChuteHeatingTemperature Maintenance up to 427°C
Maximum Exposure Temperature 538°C Maximum Watt Density ............... 4650 W/m2
SupplyVoltages....................................120-600Vac
Hopper and Chute HeatingHT Module Hopper Heater • FluoropolymerInsulatedHighTemperature1,3mm2LeadWires
(withstressreliefatconnection)
• ParallelCircuitHighTeperatureAlloyHeatingElement
• Temperature-RatedInsulation(directsenergytowardssurfacetobeheated)
• AluminizedSteelProtectiveEnclosureandCover
• 6,3mmHoleCut-outsforOptionalEarthConnection
Thermon TANK and HOPPER HEATING Products