the hart residence

24
GSPublisherEngine 0.0.100.100 Drawn by Date LB 12.02.20 Checked by Date . T1 The Hart Residence 6409 4th Avenue Takoma Park Maryland 20912 Written dimensions on these drawings shall have precedence over scale dimensions. Contractor shall verify and be responsible for all dimensions and conditions on the job and this office must be notified of any variations from the dimensions and conditions. © COPYRIGHT 10739 Tucker St #260 Beltsville MD 20705 301.579.4563 Cover Sheet THE HART RESIDENCE 6409 4TH AVENUE TAKOMA PARK MD 20912 INDEX T1 COVER SHEET T2 GENERAL NOTES D1.1 EXISTING AND DEMOLITION PLANS A1.1 FIRST AND SECOND FLOOR PLAN A1.2 ROOF PLAN A2.1 PROPOSED ELEVATIONS A2.2 3D RENDERINGS A3.1 SCHEDULES A3.2 PENETRATION DETAILS A3.3 ASSEMBLY DETAILS S0.1 STRUCTURAL NOTES S1.0 WIND BRACING PLAN S1.1 FOUNDATION PLAN, FRAMING PLAN @ 1ST FL S1.2 FRAMING PLAN @ 2ND FL, ROOF PLAN S2.1 SECTION CUTS S2.2 STRUCTURAL DETAILS M1.0 MECHANICAL NOTES M1.1 MECHANCAL DETAILS M1.2 MECHANICAL PLANS E1.0 ELECTRICAL NOTES E1.1 ELECTRICAL PLANS P1.0 PLUMBING NOTES AND RISER DIAGRAMS P1.1 PLUMBING PLANS LOCATION MAP SCOPE OF WORK 1. NEW TWO STORY REAR ADDITION (16 X 30) 2. ALTERATIONS TO EXISTING FIRST FLOOR AND SECOND FLOOR LAYOUT FOR NEW FLOOR PLAN LAYOUT. (REMOVAL OF NON LOAD BEARING WALLS) 3. NEW HVAC SYSTEM 4. NEW LIGHTING DESIGN 5. NEW SIDING AND ROOFING AT EXISTING BLDG AND NEW ADD LOCAL DESIGN LOAD CRITIA WIND SPEED: 115 MPH FROST DEPTH: 30in. EARTHQUAKE: AT SHORT PERIODS / 0.16 AT 1 SEC PERIOD / .053 SEISMIC DESIGN: B WEATHERING FOR CONCRETE: SEVERE TERMITE: MODERATE TO HEAVY DECAY: SLIGHT TO MODERATE ICE SHEILD UNDERLAYMENT : YES FLOOD HAZARDS : 3/5/1990 WINTER DESIGN: 15 D/F ; 9 D/C AIR FREEZING: LESS THAN 1500 D/F ; 815 D/F MEAN ANNUAL TEMP: 50 D/F ; 10 D/F PROJECT INFO : LOT AREA: 6420.00 LOT: 13 BLOCK: 3 FLOOR AREA OF BUILDING: 1ST: 865.50 SF, 2ND: 882.94 SF PAVED AREA: 850 SF DISTURBED AREA: 852 SF GROSS FLOOR AREA: 1748.44 SF NUMBER OF STORIES ABOVE GRADE: 2 EXISTING HT: 16'+/- PROPOSED HT: NO CHANGE BASEMENT/CELLAR: NO CONSTRUCTION TYPE: V-A MATERIALS: MASONRY(EX 1ST,2ND), WOOD (PROP 1ST,2ND) USE GROUP: R-3 ZONE: SPRINKLERED: NO SMOKE DETECTORS: HARDWIRED GAS FUEL: YES (CO DETECTORS PROVIDED) EXISTING UNITS: 1 PROPOSED UNITS: 1 FIRE RATING: NA INSULATION: EXT. WALL & FLR.: R-20+R5 CONT CEILING: R-49 BUILDING CODES 2014 NATIONAL ELECTRIC CODE 2018 INTERNATIONAL RESIDENTIAL CODE 2018 INTERNATIONAL ENERGY CONSERVATION CODE 2013 FIRE ALARM PROTECTION NFPA72 2018 INTERNATIONAL FUEL GAS CODE 2018 MECHANICAL CODE 2018 PLUMBING CODE LIFE-SAFETY NFPA1 & 101/2013 RESIDENTIAL SPRINKLER NFPA13D/2010

Upload: others

Post on 04-Dec-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: THE HART RESIDENCE

GSPublisherEngine 0.0.100.100

Drawn by DateLB 12.02.20

Checked by Date.

T1

The

Har

t Res

iden

ce64

09 4

th A

venu

eTa

kom

a Pa

rk M

aryl

and

2091

2

Written dimensions on these drawings shallhave precedence over scale dimensions.

Contractor shall verify and be responsible for alldimensions and conditions on the job and this

office must be notified of any variations from thedimensions and conditions.

© COPYRIGHT

10739 Tucker St #260Beltsville MD 20705

301.579.4563

Cov

er S

heet

THE HART RESIDENCE 6409 4TH AVENUE

TAKOMA PARK MD 20912

INDEXT1 COVER SHEETT2 GENERAL NOTESD1.1 EXISTING AND DEMOLITION PLANSA1.1 FIRST AND SECOND FLOOR PLANA1.2 ROOF PLANA2.1 PROPOSED ELEVATIONSA2.2 3D RENDERINGSA3.1 SCHEDULESA3.2 PENETRATION DETAILSA3.3 ASSEMBLY DETAILSS0.1 STRUCTURAL NOTESS1.0 WIND BRACING PLANS1.1 FOUNDATION PLAN, FRAMING PLAN @ 1ST FLS1.2 FRAMING PLAN @ 2ND FL, ROOF PLANS2.1 SECTION CUTSS2.2 STRUCTURAL DETAILSM1.0 MECHANICAL NOTESM1.1 MECHANCAL DETAILSM1.2 MECHANICAL PLANSE1.0 ELECTRICAL NOTESE1.1 ELECTRICAL PLANSP1.0 PLUMBING NOTES AND RISER DIAGRAMSP1.1 PLUMBING PLANS

LOCATION MAP SCOPE OF WORK1. NEW TWO STORY REAR ADDITION (16 X 30)2. ALTERATIONS TO EXISTING FIRST FLOOR AND SECONDFLOOR LAYOUT FOR NEW FLOOR PLAN LAYOUT. (REMOVAL OFNON LOAD BEARING WALLS)3. NEW HVAC SYSTEM4. NEW LIGHTING DESIGN5. NEW SIDING AND ROOFING AT EXISTING BLDG AND NEWADD

LOCAL DESIGN LOAD CRITIAWIND SPEED: 115 MPHFROST DEPTH: 30in.EARTHQUAKE: AT SHORT PERIODS / 0.16 AT 1 SEC PERIOD / .053SEISMIC DESIGN: BWEATHERING FOR CONCRETE: SEVERETERMITE: MODERATE TO HEAVYDECAY: SLIGHT TO MODERATEICE SHEILD UNDERLAYMENT: YESFLOOD HAZARDS: 3/5/1990WINTER DESIGN: 15 D/F ; 9 D/CAIR FREEZING: LESS THAN 1500 D/F ; 815 D/FMEAN ANNUAL TEMP: 50 D/F ; 10 D/F

PROJECT INFO:LOT AREA: 6420.00LOT: 13 BLOCK: 3FLOOR AREA OF BUILDING: 1ST: 865.50 SF, 2ND: 882.94 SFPAVED AREA: 850 SF DISTURBED AREA: 852 SFGROSS FLOOR AREA: 1748.44 SFNUMBER OF STORIES ABOVE GRADE: 2 EXISTING HT: 16'+/- PROPOSED HT: NO CHANGEBASEMENT/CELLAR: NOCONSTRUCTION TYPE: V-A MATERIALS: MASONRY(EX 1ST,2ND), WOOD (PROP 1ST,2ND)USE GROUP: R-3 ZONE:SPRINKLERED: NOSMOKE DETECTORS: HARDWIREDGAS FUEL: YES (CO DETECTORS PROVIDED)EXISTING UNITS: 1 PROPOSED UNITS: 1FIRE RATING: NAINSULATION: EXT. WALL & FLR.: R-20+R5 CONT CEILING: R-49

BUILDING CODES2014 NATIONAL ELECTRIC CODE2018 INTERNATIONAL RESIDENTIAL CODE2018 INTERNATIONAL ENERGY CONSERVATION CODE2013 FIRE ALARM PROTECTION NFPA722018 INTERNATIONAL FUEL GAS CODE2018 MECHANICAL CODE2018 PLUMBING CODE

LIFE-SAFETY NFPA1 & 101/2013RESIDENTIAL SPRINKLER NFPA13D/2010

Page 2: THE HART RESIDENCE

GSPublisherEngine 0.0.100.100

Drawn by DateLB 12.02.20

Checked by Date.

T2

The

Har

t Res

iden

ce64

09 4

th A

venu

eTa

kom

a Pa

rk M

aryl

and

2091

2

Written dimensions on these drawings shallhave precedence over scale dimensions.

Contractor shall verify and be responsible for alldimensions and conditions on the job and this

office must be notified of any variations from thedimensions and conditions.

© COPYRIGHT

10739 Tucker St #260Beltsville MD 20705

301.579.4563

Anno

tatio

ns, A

bbre

viat

ions

and

Gen

eral

Not

es

X

AABADDADJAFFAGGRALUMALTANODAPPROXARCH

BBLK'GB.M.BDBFBLBLDGBMBRGBRLBTMBTWN

CCEMCIPCJCNJTCLCLGCLRCMUCOLCONCCONNCONSTCONTCOORDCORRCRCSKCTDCTR

DDDTLSSTLDIADIMDLDNDSDWGSDWLS

EEAEJELELEVEMBDMTEOSEPOXY'DEQEQUIPEWEXISTEXP BLTEXTETR

FFDFDNFFFHCFINFLRF.R.FTFTGFV

GGAGALVGBGENGIGLSGMUGNDGRGSMGYP BD

Anchor BoltAddendrumAdjacentAbove Finished FloorAggregateAluminumAlternateAnodizedApproximateArchitectural

BlockingBench MarkBoardBackfaceBuilding LineBeamBearingBuilding Restriction LineBottomBetween

CementCast In PlaceControl JointCONSTuction JointCenter LineCeilingClearConcrete Masonry UnitColumnConcreteConnectionCONSTuctionContinuousCoordinateCorrugatedCold RolledCountersunkCenteredCenter

DepthDetailsDetailDiameterDimensionDead LoadDownDown SpoutDrawingsDowels

EachExpansion JointElevationElevationEmbedmentEdge of SlabEpoxyedEqualEquipmentEach WatExistingExpansion BoltExteriorExisting to remain

Floor DrainFoundationFinish FloorFire Hose CabinetFinishFloorFire RatedFootFootingField Verify

GaugeGalvanizedGrade BeamGeneralGalvanized IronGlassGlazed Masonry UnitGroundGradeGalvinized Sheet MetalGypsum Board

HHHDWHDRHORIZHPHRHTHWD

IIBCIDINDOINSUL

J

K

LLDGRLGLOCLPLSLLTLWC

MMANUFMASMATLMAXMDOMDFMECHMEMBMEPMFGMILMINMISCMOMODMTL

NN/ANECNICNOMNTSNWC

OOAOCODO.D.OHOPNGOPP

PPERFP.L.PLPLYWDPRPREFABPREPPSFPSIPTPTDP.T.

RRRADRCPRDREBARREFREFURBREINFRELOCREQDRFVCRO

International Building CodeInside DiameterInformationInsulation

HighHardwareHeaderHorizontalHigh PointHourHeightHardwood

LedgerLongLocationLow PointLaminated Strand LumberLightLightweight Concrete

ManufacturerMasonryMaterialMaximumMedium Density OverlayMedium Density FiberMechanicalMembraneMechanical, Electircal and PlumbingManufacturerThicknessMinimumMiscellaneousMasonry OpeningModifiedMetal

Not Available/ApplicableNecessaryNot in ContractNominalNot to ScaleNormal Weight Concrete

PerforatedProperty LinePlatePlywoodPairPrefabricatedPreparePounds per Square FootPounds per Square InchPointPaintedPressured Treated

Over AllOn CenterOutside Diam.Overflow DrainOpposite HandOpeningOpposite

RiserRadiusReflected Ceiling PlanRoof DrainReferenceRefurbishReinforcingRelocate/RelocatedRequireRecessed Fire ValveCabinetRough Opening

SS.A.B.SCHEDSECTSFSHT'GSHTSIMSISTER'DSPSOGSPECSQS.S.SSFSTAGGER'DSTDSTIDDSTIRSTCSTLSTRUCTSYMSYS

TTTAPER'DTBT&BT&GTHKTHRUTJI'STOTOBTOCTOCBTOGTOMTOSTOSTLTPTRTWTYP

UU/CU/GU.L.U.N.O.UP, NS

VVARVERTV.I.F.

WW/W/OWWPWDWFWLWPWP0WP1W.R.WWF

Sound Attenuation BoardScheduleSectionSquare FeetSheatingSheetSimilarSisteredStructural OpeningSlab on GradeSpecificationSSquareStainless SteelSolid SurfaceStaggeredStandardStiffenerStirrupSound Transmission ClassSteelStructuralSymmetricalSystem

TreadTaperedTowel BarTop and BottomTongue and GrooveThickThroughTrus Joist I JoistTop ofTop of BeamTop of ConcreteTop of CurbTop of FootingTop of MullionTop of SlabTop of SteelToilet Paper HolderTowel RingTop of WallTypical

VariesVerticalVerify In Field

Under CounterUndergroundUnderwriters LaboratoryUnless Noted OtherwiseUnprotected, Non Sprinklered

WithWithoutWidthWaterproof(ing)WoodWide FlangeWind LoadWork PointWork Point Point of OriginWork Point - NumberedWeather/Water ResistantWelded Wire Fabric

ABBREVIATIONS GENERAL NOTES

1. ALL WORK IS TO BE DONE IN CONFORMANCE WITH ALL APPLICABLE CODES AND REGULATIONS.2. CONTRACTOR SHALL CONFORM TO ALL O.S.H.A. REQUIREMENTS3. CONTRACTOR TO VISIT SITE AND COMPLETELY FAMILIARIZE HIMSELF WITH EXISTING CONDITIONS PRIOR TO EXECUTION OF ANY CONSTRUCTION, CONTACT DESIGNER PRIOR TO EXECUTING ANY WORK IN QUESTION.4. CHECK ALL DIMENSIONS ON JOB AND FULLY VERIFY PRIOR TO EXECUTION. ALL WORK TO BE FULLY EXECUTED IN ACCORDANCE WITH ALL GOVERNING CODES AND REGULATIONS. ALL ELEVATIONS GIVEN ARE APPROXIMATE AND ARE GIVEN FOR "RELATIONAL" PURPOSES. CONTRACTOR SHALL ESTABLISH EXACT LEVELS PRIOR TO START OF WORK AND NOTIFY DESIGNER OF ANY SIGNIFICANT DISCREPANCIES. CONTRACTOR TO PROVIDE SHOP DRAWINGS, COLOR SCHEDULES AND SELECTIONS FOR APPROVAL BY DESIGNER PRIOR TO EXECUTION.5. DEMOLITION: TO BE PROVIDED BY CONTRACTOR AS REQUIRED. COMPLETELY REMOVE ALL TRASH FROM SITE.6. UTILITIES: COORDINATE AND PROVIDE AS PER DRAWINGS.7. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS/ VENDOR DATA SUBMITTAL SCHEDULE TO DESIGNER FOR REVIEW AND APPROVAL WITHIN THIRTY (30) DAYS FROM COMMENCEMENT OF WORK. SUBMIT TWO (2) COPIES TO DESIGNER.8. CONTRACTOR SHALL NOT SCALE DRAWINGS AND DISCREPANCIES BETWEEN EXISTING CONDITIONS AND DRAWINGS SHALL BE REPORTED TO DESIGNER FOR CLARIFICATION PRIOR TO COMMENCEMENT OF WORK.9. CONTRACTOR SHALL BE RESPONSIBLE FOR THE INCLUSION OF ALL WORK NECESSARY FOR A COMPLETE INSTALLATION WHETHER SUCH WORK IS OR IS NOT INDICATED ON THE DRAWINGS OR IN THE SPECIFICATIONS.10. ALL MANUFACTURED ITEMS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S WRITTEN INSTRUCTIONS.11. WARRANTIES, GUARANTEES AND MANUFACTURER'S INSTRUCTIONS ON EQUIPMENT FURNISHED AND INSTALLED BY THE CONTRACTOR SHALL BE GIVEN TO THE OCCUPANT.12. CONTRACTOR SHALL PROVIDE PROTECTION ON A DAILY BASIS FOR ALL WORK THAT PENETRATES THE EXISTING ROOF MATERIAL. CONTRACTOR MAY COVER ALL WORK UNTIL WATER/WEATHER PROOF UNTIL COMPLETION OF CONSTRUCTION.13. ALL WOOD FRAMING EXPOSED TO THE WEATHER SHALL BE PRESSURE TREATED IN ACCORDANCE WITH AWPA.14. IN AREAS WHERE THE DRAWINGS DO NOT ADDRESS METHODOLOGY, THE CONTRACTOR SHALL BE BOUND TO PERFORM IN STRICT COMPLIANCE WITH MANUFACTURER'S SPECIFICATIONS AND RECOMMENDATIONS.15. IN THE EVENT CERTAIN FEATURES OF THE CONSTRUCTION ARE NOT FULLY SHOWN ON THE DRAWINGS, THEIR CONSTRUCTION SHALL BE OF THE SAME CHARACTER AS FOR SIMILAR CONDITIONS THAT ARE SHOWN OR NOTED.16. THE DESIGNER WILL NOT BE RESPONSIBLE FOR AND WILL NOT HAVE CONTROL OVER CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK. THE DESIGNER WILL NOT BE RESPONSIBLE FOR THE FAILURE OF THE CLIENT OR HIS CONTRACTORS, SUBCONTRACTORS, OR ANYONE PERFORMING ANY OF THE WORK, TO CARRY OUT THE WORK IN ACCORDANCE WITH THE APPROVED CONTRACT DOCUMENTS.17. All CONCRETE DETAILS AND CONSTRUCTION ARE TO COMPLY WITH LATEST A.C.I. CODE AND LOCAL CODES18. APPROVAL OF THESE DRAWINGS BY GOVERNING AUTHORITIES DOES NOT RELEASE THE CONTRACTOR FROM COMPLYING WITH ALL APPLICABLE CODES AND STANDARDS.19. ALL NOTES ON THIS DRAWING APPLY FOR THE ENTIRE PROJECT WHETHER OR NOT REPEATED ON OTHER DRAWINGS.20. WHERE NEW WORK IS TO BE DONE. CARE SHALL BE TAKEN TO PROTECT ALL EXISTING ADJACENT SURFACES AND AREAS FROM DAMAGE. ANY AREAS DAMAGED DURING CONSTRUCTION OR DEMOLITION SHALL BE RESTORED TO THEIR ORIGINAL CONDITION AT NO ADDITIONAL COST TO THE CLIENT. THIS APPLIES PARTICULARLY TO ADJACENT SPACES, ROOF, AND OTHER EXTERIOR AREAS AND SURFACES.21. THE OWNER WILL CONSIDER FORMAL REQUESTS FROM THE CONTRACTOR FOR SUBSTITUTION OF PRODUCTS, MATERIAL OR MANUFACTURERS. THESE REQUESTS SHALL ACCOMPANY BUT NOT BE INCLUDED IN THE BASE BID ON THE SPECIFIED BID DUE DATE. SUBMIT TWO (2) COPIES OF REQUEST FOR SUBSTITUTION.22. ONLY NEW, FIRST CLASS MATERIALS WILL BE USED (EXCEPT AS NOTED). ALL WORK AND EQUIPMENT SHALL BE WARRANTED BY THE CONTRACTOR FOR A MINIMUM OF ONE YEAR FROM THE DATE OF FINAL ACCEPTANCE EXCEPT FOR MANUFACTURER'S GUARANTEES WHICH MAY BE LONGER.23. ALL GYPSUM BOARD SHALL BE TAPED, SPACKLED AND SANDED SMOOTH PRIOR TO FINISHING, METAL BEADING SHALL BE USED ON ALL OUTSIDE CORNERS WHERE APPLICABLE.24. THE GENERAL CONTRACTOR SHALL BEAR FULL RESPONSIBILITY AND COSTS FOR THE FOLLOWING: A. PERMITS, LICENSES, INSPECTIONS AND FEES (ALL IMPACT FEES). B. TEMPORARY POWER AND UTILITIES. C. TRASH REMOVAL. D. LIABILITY AND WORKMEN'S COMPENSATION INSURANCE, ETC. E. AND OTHER ITEMS INDICATED IN SPECIFICATIONS. F. SHORING25. ALL PENETRATIONS THROUGH EXISTING ROOF SHALL BE SEALED IN PITCH POCKETS AT PIPING, CONDUIT, ETC.; FLASH DUCTS AND CRUBS.26. REMOVAL, DISPOSAL, ALTERATION AND RELOCATION OF EXISTING MECHANICAL AND ELECTRICAL EQUIPMENT, CONDUITS, PIPES AND DUCTS ARE INCLUDED IN THE WORK.

4

4

XXXXNR

XXAX.X

XXAX.X

XXAX.X

XXAX.X

XXAX.X

12

34 AX.X

¡ 1ST FLOOR

FLOOR HEIGHT IDENTIFIER

ELEVATION CALLOUT

DETAIL NUMBER

SECTION CALLOUT

DETAIL CALLOUT

INTERIOR ELEVATION

FIRE RATING

KEYNOTE4

SHEET NUMBER

SHEET NUMBER

SHEET NUMBER

SHEET NUMBER

4REVISION INDICATOR

GRAPHIC SYMBOLS

XXXXNR

WALL TYPE DESIGNATION

FLOOR/ROOF ASSEMBLYFIRE RATING

SPOT ELEVATION

XXAX.X

XXAX.X

XXAX.X

XXAX.X

XXAX.X

12

34 AX.X

0'-0"

¡ 1ST FLOOR

SHEET NUMBER

Page 3: THE HART RESIDENCE

GSPublisherEngine 0.0.100.100

The

Har

t Res

iden

ce64

09 4

th A

venu

eTa

kom

a Pa

rk M

aryl

and

2091

2

Drawn by DateLB 12.02.20

Checked by Date.

D1.1

Written dimensions on these drawings shallhave precedence over scale dimensions.

Contractor shall verify and be responsible for alldimensions and conditions on the job and this

office must be notified of any variations from thedimensions and conditions.

© COPYRIGHT

10739 Tucker St #260Beltsville MD 20705

301.579.4563

3.D1.1

Existing Roof Plan1/4" = 1'-0"

14'-1

15/8"

12'-23/4" 11'-4"

14'-1

15/8"

EXBEDROOM EX DEN

EXCLO

EXCLO

DN

DN

2.D1.1

Existing Second Floor Plan1/4" = 1'-0"

7'-13/4"

14'-1

15/8"

11'-71/2"

14'-1

15/8"

2'-6"EXKITCHEN

EX LIVINGAREA

EXBATH

EXMECHCLO

EXELECTPANEL

UP

1.D1.1

Existing First Floor Plan1/4" = 1'-0"

Exis

ting

Plan

s

Page 4: THE HART RESIDENCE

GSPublisherEngine 0.0.100.100

Drawn by DateLB 12.02.20

Checked by Date.

D1.2

The

Har

t Res

iden

ce64

09 4

th A

venu

eTa

kom

a Pa

rk M

aryl

and

2091

2

Written dimensions on these drawings shallhave precedence over scale dimensions.

Contractor shall verify and be responsible for alldimensions and conditions on the job and this

office must be notified of any variations from thedimensions and conditions.

© COPYRIGHT

10739 Tucker St #260Beltsville MD 20705

301.579.4563

3.D1.2

Existing Roof Plan1/4" = 1'-0"

14'-1

15/8"

12'-23/4" 11'-4"

14'-1

15/8"

EXBEDROOM EX DEN

EXCLO

EXCLO

DN

DN

2.D1.2

Existing Second Floor Plan1/4" = 1'-0"

7'-13/4"

14'-1

15/8"

11'-71/2"

14'-1

15/8"

2'-6"EXKITCHEN

EX LIVINGAREA

EXBATH

EXMECHCLO

EXELECTPANEL

UP

1.D1.2

Existing First Floor Plan1/4" = 1'-0"

Dem

oliti

on P

lans

ITEMS TO BE COMPLETELY DEMOLISHED

ITEMS TO REMAIN AS IS

DEMOLITION LEGEND

DEMOLISH EX WINDOWAND HARDWARE

DEMOLISH EX STAIR,WALL, DOORHARDWARECOMPLETELY

DEMOLISH EX WINDOWAND HARDWARE AND

PORTION OF WALL

DEMOLISH EXDOOR AND

HARDWARE

DEMOLISH EX WINDOWAND HARDWARE AND

PORTION OF WALL

DEMOLISH EX WINDOWAND HARDWARE ANDPORTION OF WALL

DEMOLISH EXDOOR ANDHARDWARE

DEMOLISH EX WINDOWAND HARDWARE

DEMOLISH EXPORTION OF

WALL

DEMOLISH EX WINDOWAND HARDWARE

DEMOLISH EX WINDOWAND HARDWARE

DEMOLISH EX WALL,DOOR AND HARDWARECOMPLETELY

DEMOLISH EX WALL,DOOR AND HARDWARECOMPLETELY

DEMOLISH EX WALL,WINDOW, DOOR ANDHARDWARECOMPLETELY

DEMOLISH EX LANDINGAND STAIRCOMPLETELY

DEMOLISH EX WALL,DOOR AND HARDWARE

COMPLETELY

DEMOLISH EXBATHROOMENTIRELY. EXPLUMBING LINESTO REMAIN

DEMOLISH EX HVACEQUIP ENTIRELY

DEMOLISH EX ROOFINGCOMPLETELY. PREPFOR NEW ROOFING

GENERAL DEMOLITION NOTESA. CONTRACTOR TO VERIFY IN FIELD EXISTING CONDITIONS. ANY DEFIATION FROM THE PLANSSHALL BE BROUGHT TO THE ATTENTION OF THE DESIGNER/ENGINEER IMMEDIATELY.B. BUILDING AND SITE WILL BE CONTINUED OPERATIONS DURING DEMOLITION ANDREMODELING PHASES.C. THE DEMOLITION PLAN AND EXISTING CONDITIONS SHOWN ARE APPROXIMATE. CONTRACTORSHALL FIELD VERIFY ALL EXISTING CONDITIONS AND INCLUDE IN THEIR BID. ITEMS WHICH AREINTENDED TO BE REMOVED, RELOCATED, OR SALVAGED ARE SHOWN AS DIAGONAL LINES. ALLOTHER ITEMS ARE INTENDED TO REMAIN IN PLACE.D. COORDINATE DEMOLITION AND REPAIRS, PROVIDE TEMPORARY ROOFING AS REQUIRED. DONOT LEAVE ANY AREAS EXPOSED TO ELEMENTS, WITHOUT TEMPORARY ROOFING.E. DEMOLITION SHALL INCLUDE, BUT IS NOT LIMITED TO, THE TIMES IDENTIFIED. THECONTRACTOR SHALL COORDINATE ALLREQUIRED RENOVATION AND NEW CONSTRUCTION WITHTHE EXISTING BUILDING TO IDENTIFY THE TOTAL EXTENT OF THE DEMOLITION REQUIRED ANDAS LISTED HERE-IN.F. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DEMOLITION AND REMOVAL OF ALLEXISTING BUILDING COMPONENTS,MATERIALS, EQUIPMENT, AND APPURTENANCES ASREQUIRED TO BUILD, ERECT, INSTALL, OR ACCOMODATE ALL NEW CONSTRUCTION, WITH THECONTRACTING OFFICE HAVING FIRST RIGHT OF REFUSAL ON ALL REMOVED ITEMS.G. ITEMS NOTED TO BE REMOVED AND SALVAGED OR REINSTALLED SHALL BE CAREFULLYREMOVED BY THE CONTRACTOR WITHOUT DAMAGE AND STORED OR REINSTALLED ON THE SITEAS DIRECTED. REMOVED AND SALVAGED ITEMS SHALL REMAIN THE PROPERTY OF THE OWNER.H. IN THE EVENT THE CONTRACTOR ENCOUNTERS ON THE SITE MATERIAL REASONABLEBELIEVED TO BE ASBESTOS, LEAD-BASED PAINT, OR ANY HAZARDOUS MATERIAL WHICH HASNOT BEEN RENDERED HARMLESS, THE CONTRACTOR SHALL IMMEDIATELY REPORT THECONDITION TO THE OWNER AND PROPER ABATEMENT SHALL BE DONE.I. THE CONTRACTOR IS RESPONSIBLE FOR THE ERECTION, MAINTENANCE AND REMOVAL OF ALLCONSTRUCTION ASSISTANCE DEVICES SUCH AS SCAFFOLDING AND BARRIERS.

Page 5: THE HART RESIDENCE

GSPublisherEngine 0.0.100.100

The

Har

t Res

iden

ce64

09 4

th A

venu

eTa

kom

a Pa

rk M

aryl

and

2091

2

Drawn by DateLB 12.02.20

Checked by Date.

A1.1

Firs

t Flo

or P

lan,

Sec

ond

Floo

r Pla

n

Written dimensions on these drawings shallhave precedence over scale dimensions.

Contractor shall verify and be responsible for alldimensions and conditions on the job and this

office must be notified of any variations from thedimensions and conditions.

© COPYRIGHT

10739 Tucker St #260Beltsville MD 20705

301.579.4563

F

E

F

G

H

I

I

J

K KL

M

M

7

2

2

8

7

9

9

4

14'-0

"

14'-9"

3'-0

"

3'-1"31/2"

11'-5"

3'-111/8" 5'-47/8" 6'-61/8"

6" 14'-10" 6"

15'-10"

4'-7

3/8"

5'-9

1/4"

11'-1

13/4"

7'-6

1/2"

15'-0

3/8"

31/2"

14'-1

"6"

31/2"

7'-1

"31/

2"5'

-1"

31/2"

14'-1

"6"

29'-1

1"

3'-7

7/8"

4'-6

"8'

-17/

8"6'

-11/

8"16

'-33/

8"7'

-61/

2"

1'-6" 8'-10" 4'-6"

5'-8

1/2"

4'-1

3/4"

2'-7

1/4"

31/2"

2'-0

1/2"

3'-0

1/2"

5'-01/2"

31/2"3'-1"

31/2"2'-9"

1'-01/4" 1'-01/4"

31/2"6'-1"

8'-5

3/4"

7'-1

0"

6'-4" 8'-51/2"

30'-81/2"

882.947 sq ft

W3/A3.3

W3/

A3.3

W3/A3.3

W1/A3.3

W1/

A3.3

W1/

A3.3

W1/A3.3

36" RAILING W/PICKETS 5"OC MAX, TYP

PT STAIR 7 3/4" MAX RISER10" MIN TREADS, TYP

INT STAIRRISERS: 7 3/4" MAXTREADS: 10" MINCONT RAILING ONE SIDEOF STAIRCASE, TYP

PROVIDE 36" H GUARDRAILING, TYP

LIVINGAREA

DN

DININGAREAKITCHEN

patio below

HALL

M.BATH

M.BEDROOM

CLOWIC

WC

LIN

SHELF & ROD

SHEL

F &

RO

D

TP

MIRROR MIRROR

HOOK

DW

A AB

C

C

D

M

1

2

3

5

4

6

2

2

2

4

6

7

6

30'-0

"

4'-6"

16'-0"

14'-1

15/8"

11'-11/2"

14'-81/2"

6'-101/4" 31/2" 7'-31/2" 51/4" 11'-2" 31/2" 3'-01/2"

31/2"

51/2"

31/2"

2'-5

1/2"

2'-3

"31/

2"

2'-4

3/4"

1'-6

"

1'-5"3'-31/2"

6'-4" 8'-41/2"

7'-1

0"14

'-07/

8"8'

-11/

8"

3'-4

5/8"

31/2"

11'-9

3/8"

31/2"

2'-1

"31/

2"11

'-1"

91/2"

3'-7

7/8"

5'-9

1/2"

14'-9

1/2"

9'-5

"

3'-0"

4'-8

"

31/2" 3'-53/4" 31/2" 7'-31/4"

7'-61/2" 3'-6"

1'-1

0"10

'-27/

8"

1'-6" 1'-7" 3'-4" 5'-0" 3'-0"

91/2" 14'-5" 91/2"

31/2" 2'-67/8" 53/8"

30'-81/2"

16'-3

3/4"

5'-9

1/2"

31/2"

8'-1

05/8"

3'-0

"

865.502 sq ft

GALV STL WINDOWWELL W/EGRESSLADDER, TYP

W2/

A3.3

W1/A3.3

W1/A3.3

W1/

A3.3

W1/

A3.3

W2/A3.3

INT STAIRRISERS: 7 3/4" MAXTREADS: 10" MINCONT RAILING ONE SIDEOF STAIRCASE, TYP

CONDENSER, TYP

FRAME IN EX OPGW/2X'S 16" OC.

PROVIDE 1/2" GYPBD EA SIDE, TYP

INT WALL2X4'S 16" OC W/1/2" GYP BD EASIDE, TYP

BATH WALLSPT 2X'S 16" OC W/GREENBD @ ALL WALLS ANDCEILING, DUROCK ATSHOWER WALLS, TYP

W2/A3.3

MUDROOM/LAUNDRY

DEN

EXBATH

EXMECHCLO

EXELECTPANEL

UP

BED #1

BED #2

CLO

CLO

CLO

SIDE SETBACK

PATIO

HALL

DN

SHELF & ROD

SHELF & ROD

DN

1'-6

1/8"

2'-6

"

INT STAIRRISERS: 7 3/4" MAX

TREADS: 10" MINCONT RAILING ONE SIDE

OF STAIRCASE, TYP

TP

MIRROR

HOOK

2.A1.1

Second Floor Plan1/4" = 1'-0"

1.A1.1

First Floor Plan1/4" = 1'-0"

WALL LEGEND

EXISTING WALL TO REMAIN

NEW PARTION WALL

GENERAL NOTES:1. STUD MEASUREMENTS ARE FROM UNFINISHED MATERIAL TO UNFINISHED MATERIAL.2. COORDINATE ALL FINISH MATERIALS AND ALL FINAL PRODUCTS WITH OWNER.3. ALL MEASUREMENTS NEED TO BE VERIFIED IN FIELD.4. UNLESS OTHERWISE NOTED, ALL DETAILS, SECTIONS AND NOTES SHOWN ON THEDRAWINGS ARE INTENDED TO BE TYPICAL AND SHALL APPLY TO SIMILAR CONDITIONSELSEWHERE5. ALL OMISSIONS OR CONFLICTS BETWEEN THE VARIOUS ELEMENTS OF THEDRAWINGS AND OR SPECIFICATIONS SHALL BE BROUGHT TO THE ATTENTION OF THEDESIGNER BEFORE PROCEEDING WITH ANY WORK INVOLVED6. THE CONTRACTOR SHALL VERIFY ALL JOB SITE CONDITIONS AND RELATEDDIMENSIONS PRIOR TO CONSTRUCTION7. COMPLIANCE WITH CODES AND ORDINANCES GOVERNING THE WORK SHALL BEMADE AND ENFORCED BY THE GENERAL CONTRACTOR8. MANUFACTURER'S SPECIFICATIONS FOR INSTALLATION OF MATERIALS SHALL BEFOLLOWED9. NO WORK OR ORDERING OF MATERIAL MAY BE STARTED UNTIL ALL DIMENSIONS ANDMEASUREMENTS WHICH MAY BE FOUND INDICATED ON DRAWINGS HAVE BEENVERIFIED.10. NO PLANS SHALL BE SCALED; DIMENSIONS SHALL BE USED11. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ADEQUATELY BRACING ANDPROTECTING ALL WORK DURING CONSTRUCTION AGAINST DAMAGE, BREAKAGE,COLLAPSE, DISTORTION AND MISALIGNMENT ACCORDING TO APPLICABLE CODES ANDSTANDARDS12. THE CONTRACTOR SHALL REPAIR AND RESTORE TO ITS ORIGINAL CONDITION ALLWORK AND ITEMS DAMAGED AS A RESULT OF BUILDING OPERATIONS AND SHALL LEAVETHE WORK COMPLETED TO THE TRUE INTENT OF THE DRAWINGS AND SPECIFICATIONSAND THE SATISFACTION OF THE DESIGNER AND OWNER.

13. ANY DISTURBANCE OR DAMAGE TO THE EXISTING BUILDING OR UTILITIESRESULTING EITHER DIRECTLY OR INDIRECTLY FROM THE OPERATION OF THESEDRAWINGS SHALL BE PROMPTLY REPAIRED, RESTORED OR REPLACED TO THESATISFACTION OF THE DESIGNER AT NO ADDITIONAL COST TO THE OWNER14. ALL TRANSITIONS OF NEW WORK TO EXISTING (WALLS, FLOORS AND CEILINGS)WORK SHALL BE CAREFULLY EXECUTED. EXISTING CONSTRUCTION SHALL BE REPAIREDAS NEEDED AND PATCHED TO MATCH FINISHES OF ADJACENT SURFACES15. THE CONTRACTOR SHALL COORDINATE THE WORK WITH MECHANICAL, ELECTRICAL,AND PLUMBING DRAWINGS FOR ALL NECESSARY OPENINGS AND PENETRATIONSTHROUGH WALLS, CEILINGS AND FLOORS16. ALL EXPOSED PIPES, CONDUITS OR DUCTS IN FINISHED AREAS, WHETHER SHOWNON DRAWINGS OR NOT, SHALL BE FURRED OUT WITH GYP BD17. ALL PLUMBING, ELECTRICAL AND MECHANICAL WORK WHICH SHALL BE ABANDONEDFOR PROPOSED CONSTRUCTION WORK SHALL BE CUT BACK, REROUTED, CAPPED ANDSAFED OFF18. ALL MATERIALS AND CONSTRUCTION TO BE INCORPORATED IN THE WORK SHALL BEIN STRICT ACCORDANCE WITH THE LATEST EDITION OF THE ASTM SPECIFICATIONSAPPLICABLE AND SHALL CONFORM TO THE STANDARDS AND RECOMMENDATIONS OFTHE VARIOUS TRADE INSTITUTES (A.C.I., A.I.S.C., ETC)

Page 6: THE HART RESIDENCE

GSPublisherEngine 0.0.100.100

The

Har

t Res

iden

ce64

09 4

th A

venu

eTa

kom

a Pa

rk M

aryl

and

2091

2

Drawn by DateLB 12.02.20

Checked by Date.

A1.2

Roo

f Pla

n

Written dimensions on these drawings shallhave precedence over scale dimensions.

Contractor shall verify and be responsible for alldimensions and conditions on the job and this

office must be notified of any variations from thedimensions and conditions.

© COPYRIGHT

10739 Tucker St #260Beltsville MD 20705

301.579.4563

6" 30'-81/2" 6"

6"16

'-35/

8"6"

29'-6

"6"

6" 16'-0" 6"

MTL STANDING SEAM ROOFINGON 5/8" PLYWD SHTG. PROVIDE30# FELT, TYP

PROVIDE FLASHING ATVALLEY(S), TYP

4:124:12

RID

GE

VEN

T, T

YP

SLO

PE

SLO

PE

SLOPE

SLOPE

RIDGE VENT, TYP

OHOH

OH

OH

OH

OH OH

3.A1.1

Roof Plan1/4" = 1'-0"

WALL LEGEND

EXISTING WALL TO REMAIN

NEW PARTION WALL

GENERAL NOTES:1. STUD MEASUREMENTS ARE FROM UNFINISHED MATERIAL TO UNFINISHED MATERIAL.2. COORDINATE ALL FINISH MATERIALS AND ALL FINAL PRODUCTS WITH OWNER.3. ALL MEASUREMENTS NEED TO BE VERIFIED IN FIELD.4. UNLESS OTHERWISE NOTED, ALL DETAILS, SECTIONS AND NOTES SHOWN ON THEDRAWINGS ARE INTENDED TO BE TYPICAL AND SHALL APPLY TO SIMILAR CONDITIONSELSEWHERE5. ALL OMISSIONS OR CONFLICTS BETWEEN THE VARIOUS ELEMENTS OF THEDRAWINGS AND OR SPECIFICATIONS SHALL BE BROUGHT TO THE ATTENTION OF THEDESIGNER BEFORE PROCEEDING WITH ANY WORK INVOLVED6. THE CONTRACTOR SHALL VERIFY ALL JOB SITE CONDITIONS AND RELATEDDIMENSIONS PRIOR TO CONSTRUCTION7. COMPLIANCE WITH CODES AND ORDINANCES GOVERNING THE WORK SHALL BEMADE AND ENFORCED BY THE GENERAL CONTRACTOR8. MANUFACTURER'S SPECIFICATIONS FOR INSTALLATION OF MATERIALS SHALL BEFOLLOWED9. NO WORK OR ORDERING OF MATERIAL MAY BE STARTED UNTIL ALL DIMENSIONS ANDMEASUREMENTS WHICH MAY BE FOUND INDICATED ON DRAWINGS HAVE BEENVERIFIED.10. NO PLANS SHALL BE SCALED; DIMENSIONS SHALL BE USED11. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ADEQUATELY BRACING ANDPROTECTING ALL WORK DURING CONSTRUCTION AGAINST DAMAGE, BREAKAGE,COLLAPSE, DISTORTION AND MISALIGNMENT ACCORDING TO APPLICABLE CODES ANDSTANDARDS12. THE CONTRACTOR SHALL REPAIR AND RESTORE TO ITS ORIGINAL CONDITION ALLWORK AND ITEMS DAMAGED AS A RESULT OF BUILDING OPERATIONS AND SHALL LEAVETHE WORK COMPLETED TO THE TRUE INTENT OF THE DRAWINGS AND SPECIFICATIONSAND THE SATISFACTION OF THE DESIGNER AND OWNER.

13. ANY DISTURBANCE OR DAMAGE TO THE EXISTING BUILDING OR UTILITIESRESULTING EITHER DIRECTLY OR INDIRECTLY FROM THE OPERATION OF THESEDRAWINGS SHALL BE PROMPTLY REPAIRED, RESTORED OR REPLACED TO THESATISFACTION OF THE DESIGNER AT NO ADDITIONAL COST TO THE OWNER14. ALL TRANSITIONS OF NEW WORK TO EXISTING (WALLS, FLOORS AND CEILINGS)WORK SHALL BE CAREFULLY EXECUTED. EXISTING CONSTRUCTION SHALL BE REPAIREDAS NEEDED AND PATCHED TO MATCH FINISHES OF ADJACENT SURFACES15. THE CONTRACTOR SHALL COORDINATE THE WORK WITH MECHANICAL, ELECTRICAL,AND PLUMBING DRAWINGS FOR ALL NECESSARY OPENINGS AND PENETRATIONSTHROUGH WALLS, CEILINGS AND FLOORS16. ALL EXPOSED PIPES, CONDUITS OR DUCTS IN FINISHED AREAS, WHETHER SHOWNON DRAWINGS OR NOT, SHALL BE FURRED OUT WITH GYP BD17. ALL PLUMBING, ELECTRICAL AND MECHANICAL WORK WHICH SHALL BE ABANDONEDFOR PROPOSED CONSTRUCTION WORK SHALL BE CUT BACK, REROUTED, CAPPED ANDSAFED OFF18. ALL MATERIALS AND CONSTRUCTION TO BE INCORPORATED IN THE WORK SHALL BEIN STRICT ACCORDANCE WITH THE LATEST EDITION OF THE ASTM SPECIFICATIONSAPPLICABLE AND SHALL CONFORM TO THE STANDARDS AND RECOMMENDATIONS OFTHE VARIOUS TRADE INSTITUTES (A.C.I., A.I.S.C., ETC)

Page 7: THE HART RESIDENCE

GSPublisherEngine 0.0.100.100

The

Har

t Res

iden

ce64

09 4

th A

venu

eTa

kom

a Pa

rk M

aryl

and

2091

2

Drawn by DateLB 12.02.20

Checked by Date.

A2.1

Fron

t Ele

vatio

n(N

orth

), R

ear E

leva

tion

(Sou

th),

Wes

t Ele

vatio

n, E

ast E

leva

tion

Written dimensions on these drawings shallhave precedence over scale dimensions.

Contractor shall verify and be responsible for alldimensions and conditions on the job and this

office must be notified of any variations from thedimensions and conditions.

© COPYRIGHT

10739 Tucker St #260Beltsville MD 20705

301.579.4563

6'-8

"

SLOPEDGUTTER, TYP

MTL DOWNSPOUTTO DAYLIGHT, TYP

VERTICAL SIDING.CONSULTW/OWNER

MTL STANDINGSEAM ROOFING,TYP

EXTOPWH

WH

8'-0

"8'

-2"

6'-8

"

5/4 X 4" TRIM, TYP

EX 1ST FLR

EX 2ND FLR

3'-7

"

6'-8

"

7'-3

"9"

2'-1

11/2"

6'-8

"

8'-0

"8'

-2"

SLOPED GUTTER, TYP

1X8 PVC RAKE TRIM, TYP

MTL DOWNSPOUT, TYP

VERTICAL SIDING.CONSULT W/OWNER

MTL STANDING SEAMROOFING, TYP

TOP

1ST FL

GRADE

WH

EX 1ST FL

EX 2ND FL

EX TOP

9'-0

1/2"

8'-2

"

5/4 X 4" TRIM, TYP

6'-8

"

3'-7

"6'

-9"

6'-9

"

9'-0

1/2"

8'-3

"

9'-0

1/2"

8'-3

"

SLOPED GUTTER, TYP

MTL DOWNSPOUT, TYP

VERTICAL SIDING.CONSULT W/OWNER

MTL STANDING SEAMROOFING, TYP

36" RAILING W/PICKETS 5"OC MAX, TYP

WH

EX 1ST FL

EX 2ND FL

EX TOPEX TOP

EX 2ND FL

WH

5/4 X 4" TRIM, TYP

8'-0

"8'

-2"

6'-8

"

9'-0

1/2"

8'-2

"

6'-8

"6'

-8"

WH

WH

WH

1.A2.1

Front Elevation(North)1/4" = 1'-0"

3.A2.1

West Elevation1/4" = 1'-0"

4.A2.1

East Elevation1/4" = 1'-0"

2.A2.1

Rear Elevation(South)1/4" = 1'-0"

Page 8: THE HART RESIDENCE

GSPublisherEngine 0.0.100.100

Drawn by DateLB 12.02.20

Checked by Date.

A2.2

The

Har

t Res

iden

ce64

09 4

th A

venu

eTa

kom

a Pa

rk M

aryl

and

2091

2

Written dimensions on these drawings shallhave precedence over scale dimensions.

Contractor shall verify and be responsible for alldimensions and conditions on the job and this

office must be notified of any variations from thedimensions and conditions.

© COPYRIGHT

10739 Tucker St #260Beltsville MD 20705

301.579.4563

3d V

iew

s D

D2

Page 9: THE HART RESIDENCE

GSPublisherEngine 0.0.100.100

Drawn by DateLB 12.02.20

Checked by Date.

A3.1

The

Har

t Res

iden

ce64

09 4

th A

venu

eTa

kom

a Pa

rk M

aryl

and

2091

2

Written dimensions on these drawings shallhave precedence over scale dimensions.

Contractor shall verify and be responsible for alldimensions and conditions on the job and this

office must be notified of any variations from thedimensions and conditions.

© COPYRIGHT

10739 Tucker St #260Beltsville MD 20705

301.579.4563

Page 3 of 6 Revised 10/1/2020

PRESCRIPTIVE WORKSHEET (R-Values)

Applicant Name: ________________________________________ Date: ____________________

Building Address ________________________________________ Permit (A/P) # _____________

CRITERIA REQUIRED PROVIDED ASSEMBLY DESCRIPTION

WINDOWS/DOORS GLAZED FENESTRATION

MAX.U-FACTOR

0.32

MAX. SHGC

0.55

SKYLIGHTS

MAX.U-FACTOR

0.4

MAX. SHGC

0.4

CEILINGS

MIN

IMU

M

R-V

AL

UE

R-49

WALLS (wood framing) R-20 or13+5

MASS WALLS **R-8/13

BASEMENT WALLS *R-10/13

FLOORS R-19

SLAB PERIMETER R-value, depth

R-10, 2ft

CRAWL SPACE WALLS *R-10/13

*The first R-value applies to continuous insulation, the second to framing cavity insulation. “10/13 means R-10continuous insulated sheathing on the interior or exterior of the home or R-13 cavity insulation on the interior of thebasement wall.”

**The second R-value applies when more than half the insulation is on the interior of the mass wall. Insulation material used in layers, such as framing cavity insulation and insulating sheathing, shall be summed to compute the component R-value.

Thermally Isolated Sunroom, Check box if applicable.

• Minimum Ceiling R-Value for Sunroom (R-19)

• Minimum Wall R-Value (R-13)

• New wall(s) separating a sunroom from conditioned space shall meet the building thermal envelope requirements.

I hereby certify that the building design represented in the attached construction documents has been designed to meet or exceed the requirements of: 2

□ 2018 Edition International Energy Conservation Code (IECC)

___________________________ ____________________________ ____________ Builder/Designer/Contractor Company Name Date

2 Section R103.3.1 “Documents shall be endorsed and stamped “Reviewed for Code Compliance.” Section R103.3.3 provides provision for Phased Approval. “The

code official shall have the authority to issue a permit for the construction of part of an energy conservation system before the construction documents for the entire

system have been submitted or approved, provided adequate information and detailed statements have been filed complying with all pertinent requirements of this code.

The holders of such permit shall proceed at their own risk without assurance that the permit for the entire energy conservation system will be granted.”

RESIDENTIAL ENERGY EFFICIENCY

2017 DISTRICT OF COLUMBIA ENERGY CONSERVATION CODE R-17

TABLE R402.4.1.1AIR BARRIER AND INSULATION INSTALLATION

a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.

COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA

General requirements

A continuous six-sided air barrier shall be installed in the building envelope.The exterior thermal envelope contains a continuous air barrier.Breaks or joints in the air barrier shall be sealed.

Air-permeable insulation shall not be used as a sealing material. All ceiling, wall, floor and slab insulation shall achieve Grade I installation per the RESNET Standards or, alternatively, Grade II for surfaces that contain a layer of continuous, air impermeable insulation > R5.

Ceiling/attic

The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed.Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed.

The insulation in any dropped ceiling/soffit shall be aligned with the air barrier.

Walls

The junction of the foundation and sill plate shall be sealed.The junction of the top plate and the top of exterior walls shall be sealed.Knee walls shall be sealed.

Cavities within corners and headers of frame walls shall be insulated by completely filling the cavity with a material having a thermal resistance of not less than R-3 per inch.Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier.

Windows, skylights and doors

The space between window/door jambs and framing, and skylights and framing shall be sealed. Doors adjacent to unconditioned space or ambient conditions shall be made substantially air-tight with weather stripping or equivalent gasket.

Continuous exterior insulation shall continue over window and door headers.Skylight and window chases through unconditioned attic space must be insulated to exterior wall values per table 402.1.2.

Rim joists Rim joists shall include continuous air barrier. Rim joists shall be insulated per Table 402.1.2.

Floors (including above garage and cantilevered floors)

The air barrier shall be installed at any exposed edge of insulation.

Floor framing cavity insulation shall be installed to maintain permanent contact with the underside of subfloor decking, or floor framing cavity insulation shall be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members.

Crawl space wallsExposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder withoverlapping joints taped.

Where provided instead of floor insulation,insulation shall be permanently attached to the crawlspace walls.

Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed.

Duct shafts or chases next to exterior or unconditioned space shall be insulated.

Narrow cavities

Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity space.

Garage separation Air sealing shall be provided between the garage and conditioned spaces.

Walls next to unconditioned garage space shall be insulated.

Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be sealed to the drywall.

Recessed light fixtures installed in the building thermal envelope shall be air tight and IC rated.

Plumbing and wiring Seal any plumbing or wiring that penetrates the building envelope.

Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring.

Shower/tub on exterior wallThe air barrier installed at exterior walls adjacent to showers and tubs shall separate them from the showers and tubs.

Exterior walls adjacent to showers and tubs shall be insulated.

Electrical/phone box on exterior wallsThe air barrier shall be installed behind electrical or communication boxes or air-sealed boxes shall be installed.

Common wall separating dwelling units Air barrier is installed in common wall between dwelling units.

HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the subfloor or drywall.

Concealed sprinklers

When required to be sealed, concealed fire sprinklers shall only be sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings.

Fireplace An air barrier shall be installed on fireplace walls.

RESIDENTIAL ENERGY EFFICIENCY

R-18 2017 DISTRICT OF COLUMBIA ENERGY CONSERVATION CODE

R402.5 Maximum fenestration U-factor and SHGC (Man-datory). The area-weighted average maximum fenestrationU-factor permitted using tradeoffs from Section R402.1.5 orR406 shall be 0.40 for vertical fenestration, and 0.75 for sky-lights.

R402.6 Cool roof requirements. Roof coverings for roofslopes less than or equal to two units vertical in 12 unitshorizontal (17 percent slope or less) for buildings and cov-ered parking shall conform to this section. A minimum of75 percent of the entire roof surface not used for roof pen-etrations, renewable energy power systems (e.g., photovol-taics or solar thermal collectors), harvesting systems forrainwater to be used on-site, or green roofing systems shallbe covered with products that comply with one or both ofthe following:

1. Have a 3-year-aged Solar Reflective Index (SRI) of notless than 64.

2. Comply with the criteria for roof products as defined in“ENERGY STAR® Program Requirements, ProductSpecification for Roof Products, Eligibility Criteria.”

Exceptions:

1. Building projects where an annual energy analysissimulation demonstrates that the total annual build-ing energy consumption with the proposed roof is 2percent less than it would be with a roof having athree-year-aged SRI of 64.

2. Roofs used to shade or cover parking and roofs oversemi-heated spaces or used as outdoor recreationspace by the occupants of the building shall be per-mitted to be either landscaped or have a minimuminitial SRI of 29. A default SRI value of 35 for newconcrete without added color pigment is allowed tobe used in lieu of measurements.

3. Terraces on setbacks comprising less than 25 per-cent of the area of the largest floor plate in the build-ing.

4. Green roofs shall be permitted to comprise part orall of the 75 percent required area coverage.

R402.6.1 Solar Reflective Index. Initial and aged val-ues of the SRI shall be calculated in accordance withASTM E1980 for medium-speed wind conditions, usinga convection coefficient of [2.1 BTU/(h · ft2 · °F)] or themetric equivalent [12 W/(m2 · K)]. The SRI shall bebased upon solar reflectance as measured in accordance

with ASTM E1918 or ASTM C1549, and the thermalemittance as measured in accordance with ASTM E408or ASTM C1371. For roofing products, the values forsolar reflectance and thermal emittance shall be deter-mined by a laboratory accredited by a nationally recog-nized accreditation organization, such as the Cool RoofRating Council CRRC-1 Product Rating Program, andshall be labeled and certified by the manufacturer.

SECTION R403 SYSTEMS

R403.1 Controls (Mandatory). At least one thermostat shallbe provided for each separate heating and cooling system.

R403.1.1 Programmable thermostat. The thermostatcontrolling the primary heating or cooling system of thedwelling unit shall be capable of controlling the heatingand cooling system on a daily schedule to maintain differ-ent temperature set points at different times of the day.This thermostat shall include the capability to set back ortemporarily operate the system to maintain zone tempera-tures down to 55°F (13°C) or up to 85°F (29°C). The ther-mostat shall initially be programmed by the manufacturerwith a heating temperature set point no higher than 70°F(21°C) and a cooling temperature set point no lower than78°F (26°C).

R403.1.2 Heat pump supplementary heat (Mandatory).Heat pumps having supplementary electric-resistance heatshall have controls that, except during defrost, preventsupplemental heat operation when the heat pump compres-sor can meet the heating load.

R403.2 Hot water boiler outdoor temperature setback.Hot water boilers that supply heat to the building throughone- or two-pipe heating systems shall have an outdoor set-back control that lowers the boiler water temperature basedon the outdoor temperature.

R403.3 Ducts. Ducts and air handlers shall be in accordancewith Sections R403.3.1 through R403.3.5.

R403.3.1 Insulation (Mandatory). Supply and returnducts outside of the building thermal envelope shall beinsulated to not less than R-8.

Exception: Where ducts are less than 3 inches (76 mm)in diameter, not less than R-6 is allowed.

R403.3.2 Sealing (Mandatory). Ducts, air handlers andfilter boxes shall be sealed. Joints and seams shall comply

TABLE R402.4.1.2MAXIMUM ALLOWED AIR LEAKAGE RATES

New constructionLevel 3 Alteration affecting 80% or more of the aggregate work of the building (Gut Rehabilita-tion)

Single family detached, two family attached (duplex), townhouses, flats

3 ACH50 3 ACH50

Dwelling units in Multifamily buildings 3 stories and less

.30 CFM50/SF enclosure area of each unit or 3 ACH50

.30 CFM50/SF enclosure area of each unit or 3 ACH50

GENERAL REQUIREMENTS

2017 DISTRICT OF COLUMBIA ENERGY CONSERVATION CODE R-11

TABLE R303.1.3(1) DEFAULT GLAZED FENESTRATION U-FACTORS

FRAME TYPE SINGLEPANE

DOUBLEPANE

SKYLIGHT

Single Double

Metal 1.20 0.80 2.00 1.30

Metal with Thermal Break 1.10 0.65 1.90 1.10

Nonmetal or Metal Clad 0.95 0.55 1.75 1.05

Glazed Block 0.60

TABLE R303.1.3(2) DEFAULT DOOR U-FACTORS

DOOR TYPE U-FACTOR

Uninsulated Metal 1.20

Insulated Metal 0.60

Wood 0.50

Insulated, nonmetal edge, max 45% glazing, any glazing double pane

0.35

TABLE R303.1.3(3) DEFAULT GLAZED FENESTRATION SHGC AND VT

SINGLE GLAZED DOUBLE GLAZED GLAZED BLOCK

Clear Tinted Clear Tinted

SHGC 0.8 0.7 0.7 0.6 0.6

VT 0.6 0.3 0.6 0.3 0.6

RESIDENTIAL ENERGY EFFICIENCY

R-14 2017 DISTRICT OF COLUMBIA ENERGY CONSERVATION CODE

R402.2.1 Ceilings with attic spaces. Where SectionR402.1.2 would require R-49 insulation in the ceiling butthe depth of the roof rafters does not allow R-49, the ceil-ing insulation value may be reduced to R-38. This reduc-tion shall not apply to the U-factor alternative approach inSection R402.1.4 and the total UA alternative in SectionR402.1.5.

R402.2.2 [Reserved]

R402.2.3 Eave baffle. For air-permeable insulation invented attics utilizing eave vents, a baffle shall be installedadjacent to soffit and eave vents. Baffles shall maintain anopening equal or greater than the size of the vent. The baf-fle shall extend over the top of the attic insulation. Thebaffle may be any solid material.

R402.2.4 Access hatches and doors. Access doorsfrom conditioned spaces to unconditioned spaces suchas attics and crawl spaces shall be weatherstripped andinsulated to a level equivalent to the insulation on thesurrounding surfaces. Access shall be provided to allequipment that prevents damaging or compressing theinsulation. A wood-framed or equivalent baffle orretainer is required to be provided when loose-fill insu-lation is installed, the purpose of which is to prevent theloose-fill insulation from spilling into the living spacewhen the attic access is opened, and to provide a perma-

nent means of maintaining the installed R-value of theloose-fill insulation.

Exception: Vertical doors that provide access fromconditioned to unconditioned spaces shall be permittedto meet the fenestration requirements of TableR402.1.2.

R402.2.5 Mass walls. Mass walls for the purposes of thischapter shall be considered above-grade walls of concreteblock, concrete, insulated concrete form (ICF), masonrycavity, brick (other than brick veneer), earth (adobe, com-pressed earth block, rammed earth) and solid timber/logs,or any other walls having a heat capacity greater than orequal to 6 Btu/ft2 × °F (123 kJ/m2 × K).

R402.2.6 Steel-frame ceilings, walls and floors. Steel-frame ceilings, walls, and floors shall meet the insulationrequirements of Table R402.2.6 or shall meet the U-fac-tor requirements of Table R402.1.4. The calculation ofthe U-factor for a steel-frame envelope assembly shalluse a series-parallel path calculation method.

R402.2.7 Walls with partial structural sheathing.Where Section R402.1.2 would require continuous insula-tion on exterior walls and structural sheathing covers 40percent or less of the gross area of all exterior walls, thecontinuous insulation R-value shall be permitted to bereduced by an amount necessary to result in a consistent

TABLE R402.1.2INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENTa

For SI: 1 foot = 304.8 mm.a. R-values are minimums. U-factors and SHGC are maximums. When insulation is installed in a cavity which is less than the label or design thickness of the

insulation, the installed R-value of the insulation shall not be less than the R-value specified in the table.b. The fenestration U-factor column excludes skylights. The SHGC column applies to all glazed fenestration. c. The second R-value applies when more than half the insulation is on the interior of the mass wall.d. R-5 shall be added to the required slab edge R-values for heated slab.

Fenestration U-Factorb 0.30 U-Factor

Skylightb U-Factor 0.55 U-Factor

Glazed Fenestration SHGCb 0.40 Solar Heat Gain Coefficient (SHGC)

Ceiling R-49

Wood Frame Wall and Rim Joists

R-19 in cavity + R-5 continuous on the exterior,

or R-13 in cavity + R-10 continuous on the exterior,

or R-15 continuous

Mass Wallc R-15 continuous on the exterior,

or R-20 continuous on the interior

Frame Floor R-25 + R-5 continuous

Elevated Slab R-15 continuous

Basement Wall

R-19 cavity + R-5 continuous on the exterior,

or R-13 in cavity + R-10 continuous on the exterior,

or R-15 continuous

Slab on Graded R-10 perimeter insulation for a depth of 2 ft.

Conditioned Crawlspace WallR-19 cavity + R-5 continuous on the exterior,

or R-13 in cavity + R-10 continuous on the exterior,

or R-15 continuous

CEILING GYP BDTAPED TO WALLGYP BD

GYP BDCAULKED TOTOP PLATE

KRAFT-FACEDCAVITY INSUL

CONTINUOUS GYPBD CAULKED TOBOTTOM PLATE

SUBFLOOR GLUEDTO RIM JOIST/RIMCLOSURE

KRAFT-FACEDCAVITY INSUL

CONTINUOUS MINIMALEXPANDING FOAM ATWINDOW PERIMETER

WINDOW UNIT AS AIRBARRIER

CONTINUOUSBEAD OFSEALANT

GYP BD CAULKEDTO TOP PLATE

RIM JOIST/RIMCLOSURE CAULKED

OR GASKETED TO TOPPLATE

KRAFT-FACEDCAVITY INSUL

CONTINUOUS GYPBD CAULKED TOBOTTOM PLATE

SUBFLOOR GLUEDTO RIM JOIST/RIMCLOSURE

KRAFT-FACEDCAVITY INSUL

CONTINUOUSBEAD OF SEALANT

CONTINUOUS SILLSEALER-FULL WIDTH

OF MUDSILL

FOUNDATION WALL ASAIR BARRIER

CONCRETE SLABAS AIR BARRIER

VAPOR IMPERMEABLECONTINOUSINSULATION

CONTINUOUSMINIMAL EXPANDING

FOAM AT WINDOWPERIMETER

1.A3.1

BUILDING ENVELOPE SECTION (AIR BARRIER)

6. 402.4.4 Fenestration air leakage. Windows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot (1.5 L/s/m2), and swinging doors nomore than 0.5 cfm per square foot (2.6 L/s/m2), when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled bythe manufacturer.7. Exterior door u factor = .30

Sche

dule

s

1. WINDOWS SPECIFIED ARE BY: OKNA WINDOWS, INC

3. PROVIDE ALL THE NECESSARY HARDWARE, WEATHER STRIPPING, TRIM PIECES, ETC.

SYM.

FRAMECAT. NO. TYPE

4. PROVIDE SCREENS FOR ALL OPERABLE WINDOWS. COLOR TO BE SELECTED BY OWNER.5. REFER TO PLANS AND ELEVATIONS FOR WINDOW LOCATIONS. VERIFY SIZES AND QUANTITES.6. APPLY FOAM BACKER ROD AND CAULK TO EXTERIOR PERIMITER OF TRIM AT SIDING JOINT.

2. WINDOWS ARE: ALUM, LOW "E" COATING W/ARGON GAS UNLESS OTHERWISE NOTED

WINDOW SCHEDULE

INFORMATION

W HQTY.

U-FACTOR

A 322 48.24B AWNING241 24C CASEMENT362 48D 241 24E FIXED771 71F PICTURE/CASEMENT941 79G AWNING721 32H AWNING361 36I CASEMENT282 71

DOUBLE HUNG

PICTURE/CASEMENT

NOTES:

2. All door hardware "TO BE SELECTED BY OWNER" unless otherwised noted1. Check drawings for swing directions and locations.

5. Rated doors to have compatible equal rated frames.

3. Exterior doors are by "Weathershield". Verify with manufacturer prior to install4. Shop drawings to be submitted to Designer for approval.

DOOR SCHEDULEDOOR

DOORNO

TYPE HGT WIDTH THICK MATERIAL FINISH/COLOR

FRAME

MATERIAL REMARKSFINISH/COLOR

1 PAINTED

DETAILS

HEAD JAMB QT.Y

1

2 13/8" 5

3

13/4"

16'-8"

4 13/4" 36'-8"

5 2'-8" 16'-8"

6'-8"

2'-8"6'-8"

2'-6"

4'-0"

6'-0"

PAINTED

PAINTED

PAINTED

PAINTED PAINTED

PAINTED

PAINTED

PAINTED

PAINTED

WOOD

WOOD

FIB/GLS

EXT DOORFIB/GLS

WOOD

WOOD

WOOD

FIB/GLS

13/8"

WD/GLS WOOD

EXT SLIDER

13/4"6 5'-0" 36'-8" PAINTED PAINTEDFIB/GLS FIB/GLS

13/4"

INT BIFOLD DOOR

INTERIOR LOUVER DOOR

INTERIOR DOOR

J DOUBLE HUNG362 36K CASEMENT282 71L CASEMENT361 72M PICTURE183 24

7 2'-0" 36'-8" PAINTED PAINTED INT DOOR

8 1'-10" 16'-8" PAINTED PAINTED

13/8"9 4'-0" 16'-8" PAINTED PAINTED

13/4"10 2'-8" 16'-8" PAINTED PAINTEDFIB/GLS FIB/GLS EXT DOOR

13/8"

13/8" WOOD

WOOD

WOOD

WOOD

WOOD

WOOD

EXT DOOR

INT DOOR

INT DOOR

DANIEL HART

6409 4TH STREET, TAKOMA PARK MD 20912

.24

.55

NA

NA

R-49

R-20

NAR-10

R-30

R-10

NA

CLOSED CELL FOAM INSULATION

BATT INSULATION

CONT RIGID INSULATIONBATT INSULATION

RIGID INSULATION

ARGON GAS,DOUBLE PANE, FOAM FILLED

LYNNETTE BRUNSON BRUNSON DESIGNS, LLC 11.19.20

11.19.20

ATTIC HATCH DOOR DETAIL

NOTE:a baffle shall be installed adjacent to soffit and eavevents. Baffles shall maintain an opening equal or greaterthan the size of the vent. The baffle shall extend over thetop of the attic insulation. The baffle shall be permitted tobe any solid material.

BUILDING ENVELOPE DETAIL: ATROOF/EAVE/SOFFIT

GRAPHICAL PURPOSES ONLY

.24

.24

.24

.24

.24

.24

.24

.24

.24

.24

.24

.24

Page 10: THE HART RESIDENCE

GSPublisherEngine 0.0.100.100

Drawn by DateLB 12.02.20

Checked by Date.

A3.2

The

Har

t Res

iden

ce64

09 4

th A

venu

eTa

kom

a Pa

rk M

aryl

and

2091

2

Written dimensions on these drawings shallhave precedence over scale dimensions.

Contractor shall verify and be responsible for alldimensions and conditions on the job and this

office must be notified of any variations from thedimensions and conditions.

© COPYRIGHT

10739 Tucker St #260Beltsville MD 20705

301.579.4563

VAR

IES

VARIES

7'-0

" MIN

.TO

FLO

OR2X4 WOOD FURRING

MECHANICAL DUCT. REF MECHDWGS

2X BLOCKING AS REQ.

1/2" GYP BD

VAR

IES

VARIES

7'-0

" MIN

.TO

FLO

OR

1/2" GYP BD

2X4 WOOD FURRING

MECHANICAL DUCT REF.TO MECH DWG'S

2X BLOCKING AS REQ.

1/2" RESILIENT FURRINGCHANNEL

WOOD JOIST. SEE STRUCT

1/2" GYPSUM BOARD

CONTINUOUS BEAD OF GREEN GLUEBETWEEN GYPSUM BOARD BOXENCLOSURE AND THE CEILING GYP BD

RECESSED LIGHTING FIXTURE

1/2" RESILIENT FURRINGCHANNEL @ 16" O.C.

BLOCKING AS REQUIRED

FILL THE CAVITY BETWEEN THE GYP BDENCLOSURE AND THE JOIST W/ SOUNDPROOF STONE WOOL INSULATION

3" SOUNDPROOF STONEWOOL INSULATION TO

INFILL THE JOIST CAVITY

3/4" T&G OSB SUBFLOOR NAILED DOWNINTO THE FLOOR JOIST

± 1" GYPSUM TOPPING ACOUSTIC MAT

HARDWOOD FLOORING UNDERLAYMENTSAS PER MANUF. RECC.

3/4 T&G FLOATING HARDWOOD FLOORING

1. Floor/ceiling assembly:

A.. Flooring system: 5/8" thick plywood/2"x 4" continuous wood decking.

B. Wood joist: Nom. 2" x 10" lumber joist.

C. Ceiling system: 1 layer of 5/8" gypsum wallboard, per UL Design.

2. Metallic pipe:

A. Steel pipe: 8" diameter (or smaller) schedule 40 (or heavier) steel pipe.

B. Iron pipe: 8" diameter (or smaller) cast or ductile iron pipe.

C. Conduit: 4" diameter (or smaller) electrical metallic tubing (EMT) or steel conduit.

D. Copper tubing: 4" diameter (or smaller) Type L (or heavier) copper tubing.

E. Copper pipe: 4" diameter (or smaller) regular (or heavier) copper pipe. Annular space from minimum 0" to maximum 7/8".

3. Forming and fire stop materials:

A. Forming material (optional): Foam backer rod packed into opening as a permanent form.

B. Type IA: Minimum 1/2" thick sealant applied within the annulus, flush with the top of the floor and bottom of the ceiling assemblies.

Additional sealant to be applied such that a minimum 1/2" crown is formed around the penetrating item.

F-C-1069

SECTION PLAN

USG SHEETROCK © BRAND FIRECODE

CORE GYPSUM PANELS

USG SHEETROCK FIRECODE ® COMPOUND

PIPE COVERING AND THROUGH

PENETRATION

WALL ASSEMBLY

Scale: 3" = 1' - 0"

SYSTEM NO. W-L-5044

9

F-RATING 2 HR/ T-RATING 3/4 HR

SECTION PLAN

USG SHEETROCK © BRAND FIRECODE

CORE GYPSUM PANELS

USG SHEETROCK FIRECODE ®

COMPOUND 1" [25] MIN.

PIPE COVERING AND THROUGH

PENETRATION

WALL ASSEMBLY

Scale: 3" = 1' - 0"

SYSTEM NO. W-L-1027

1

F-RATING 2 HR/ T-RATING 0 HR

FORMING MATERIAL, MINERAL FIBER

INSULATION

SECTION PLAN

USG SHEETROCK © BRAND FIRECODE

CORE GYPSUM PANELS

USG SHEETROCK FIRECODE ®

COMPOUND 5/8" [16] MIN, WITH

3

8

"

[10] CROWN. OVERLAP DRYWALL

BY 1" [25] MIN.

PIPE COVERING AND THROUGH

PENETRATION

WALL ASSEMBLY

Scale: 3" = 1' - 0"

SYSTEM NO. W-L-1087

6

F-RATING 1 HR/ T-RATING 0 & 1 HR

3/8" [10]

1" [25]

SECTION PLAN

USG SHEETROCK © BRAND FIRECODE

CORE GYPSUM PANELS

USG SHEETROCK FIRECODE ®

COMPOUND 1/2" [12] MIN.

PIPE COVERING AND THROUGH

PENETRATION

WALL ASSEMBLY

Scale: 3" = 1' - 0"

SYSTEM NO. W-L-1039

2

F-RATING 1 HR/ T-RATING 0 & 1 HR

SECTION PLAN

USG SHEETROCK © BRAND FIRECODE

CORE GYPSUM PANELS

USG SHEETROCK FIRECODE ® COMPOUND

OR USG SHEETROCK BRAND ACOUSTICAL

SEALANT, 1" [25] MIN. THICKNESS.

PIPE COVERING AND THROUGH

PENETRATION

WALL ASSEMBLY

Scale: 3" = 1' - 0"

SYSTEM NO. W-L-1064

4

F-RATING 2 HR / T-RATING 0 HR

FORMING MATERIAL, MINERAL FIBER

INSULATION, 2

1

2

" [63] MIN. THICKNESS.

Scale: 3" = 1' - 0"

SYSTEM NO. W-L-1063

3

F-RATING 2 HR/ T-RATING 0 HR

SECTION PLAN

USG SHEETROCK FIRECODE ®

COMPOUND 1" [25] MIN.

THICKNESS

PIPE COVERING AND THROUGH

PENETRATION

WALL ASSEMBLY

USG SHEETROCK © BRAND FIRECODE

CORE GYPSUM PANELS

USG SHEETROCK © BRAND FIRECODE

CORE GYPSUM PANELS

USG SHEETROCK

FIRECODE ® COMPOUND

1" [25] MIN. THICKNESS.

PIPE COVERING AND THROUGH

PENETRATION

WALL ASSEMBLY

FORMING MATERIAL, MINERAL FIBER

INSULATION

Scale: 3" = 1' - 0"

SYSTEM NO. W-L-1065

5

F-RATING 2 HR/ T-RATING 2 HR

Scale: 3" = 1' - 0"

SYSTEM NO. W-L-7001

10

F-RATING 1 HR/ T-RATING 0 HR

Scale: 3" = 1' - 0"

SYSTEM NO. W-L-7002

11

F-RATING 2 HR

USG SHEETROCK © BRAND FIRECODE

CORE GYPSUM PANELS

USG SHEETROCK FIRECODE ®

COMPOUND

1/2" [12] MIN.

THICKNESS.

AIR DUCT

WALL ASSEMBLY

USG SHEETROCK © BRAND FIRECODE

CORE GYPSUM PANELS

USG SHEETROCK FIRECODE ®

COMPOUND

1" [25] MIN.

THICKNESS.

WALL ASSEMBLY

FORMING MATERIAL, MINERAL FIBER

INSULATION

FORMING MATERIAL, MINERAL FIBER

INSULATION, 2

1

2

" [63] MIN. THICKNESS.

AIR DUCT

SECTION PLAN

USG SHEETROCK © BRAND FIRECODE

CORE GYPSUM PANELS

USG SHEETROCK FIRECODE ®

COMPOUND 1" [25] MIN.

PIPE COVERING AND THROUGH

PENETRATION

WALL ASSEMBLY

FORMING MATERIAL, MINERAL FIBER

INSULATION

SECTION PLAN

SECTION PLAN

SECTION PLAN

Scale: 3" = 1' - 0"

SYSTEM NO. W-L-3023

7

F-RATING 1 & 2 HR/ T-RATING 0 & 1 HR

SECTION PLAN

USG SHEETROCK © BRAND FIRECODE

CORE GYPSUM PANELS

USG SHEETROCK FIRECODE

® COMPOUND 1/2" [12] MIN.

PIPE COVERING AND THROUGH

PENETRATION

FORMING MATERIAL, MINERAL FIBER

INSULATION

Scale: 3" = 1' - 0"

SYSTEM NO. W-L-3034

8

F-RATING 1 HR/ T-RATING 0 & 1 HR

WALL ASSEMBLY

REFERENCE CURRENT UL JOINT SYSTEMS DIRECTORY

FOR ALL GENERAL INFORMATION, MATERIAL

DESIGNATIONS, THICKNESS AND FIRE RATINGS.

REFERENCE CURRENT UL JOINT SYSTEMS DIRECTORY

FOR ALL GENERAL INFORMATION, MATERIAL

DESIGNATIONS, THICKNESS AND FIRE RATINGS.

REFERENCE CURRENT UL JOINT SYSTEMS DIRECTORY

FOR ALL GENERAL INFORMATION, MATERIAL

DESIGNATIONS, THICKNESS AND FIRE RATINGS.

REFERENCE CURRENT UL JOINT SYSTEMS DIRECTORY

FOR ALL GENERAL INFORMATION, MATERIAL

DESIGNATIONS, THICKNESS AND FIRE RATINGS.

REFERENCE CURRENT UL JOINT SYSTEMS DIRECTORY

FOR ALL GENERAL INFORMATION, MATERIAL

DESIGNATIONS, THICKNESS AND FIRE RATINGS.

REFERENCE CURRENT UL JOINT SYSTEMS DIRECTORY

FOR ALL GENERAL INFORMATION, MATERIAL

DESIGNATIONS, THICKNESS AND FIRE RATINGS.

REFERENCE CURRENT UL JOINT SYSTEMS DIRECTORY

FOR ALL GENERAL INFORMATION, MATERIAL

DESIGNATIONS, THICKNESS AND FIRE RATINGS.

REFERENCE CURRENT UL JOINT SYSTEMS DIRECTORY

FOR ALL GENERAL INFORMATION, MATERIAL

DESIGNATIONS, THICKNESS AND FIRE RATINGS.

REFERENCE CURRENT UL JOINT SYSTEMS DIRECTORY

FOR ALL GENERAL INFORMATION, MATERIAL

DESIGNATIONS, THICKNESS AND FIRE RATINGS.

REFERENCE CURRENT UL JOINT SYSTEMS DIRECTORY

FOR ALL GENERAL INFORMATION, MATERIAL

DESIGNATIONS, THICKNESS AND FIRE RATINGS.

REFERENCE CURRENT UL JOINT SYSTEMS DIRECTORY

FOR ALL GENERAL INFORMATION, MATERIAL

DESIGNATIONS, THICKNESS AND FIRE RATINGS.

ISSUE LOG

US

G C

OR

PO

RA

TIO

N

Un

ite

d S

ta

te

s G

yp

su

m C

om

pa

ny

55

0

WE

ST

A

DA

MS

S

TR

EE

T

CH

IC

AG

O,

I

LL

IN

OI

S

6

06

61

US

G-

4Y

OU

W

WW

.U

SG

.C

OM

SHEET INFORMATION

ABCDE

43

21

ABCDE

DISCLAIMER: THE USG PRODUCT DETAILS CONTAINED HEREIN

ARE INTENDED FOR USE AS PRODUCT REFERENCE MATERIAL BY

ARCHITECTS, ENGINEERS, OTHER DESIGN PROFESSIONALS,

CONTRACTORS, BUILDING CODE OFFICIALS, OR OTHER

COMPETENT CONSTRUCTION INDUSTRY TRADE PROFESSIONALS

HAVING AN INTEREST IN THE SELECTION, SPECIFICATION AND

USE OF PRODUCTS MANUFACTURED BY THE SUBSIDIARIES OF

USG CORPORATION. THE DRAWINGS ARE INTENDED SOLELY AS

TECHNICAL SUPPORT INCIDENT TO THE SALE AND USE OF USG

PRODUCTS AND NOT INTENDED TO BE A SUBSTITUTE FOR THE

DESIGN REVIEW AND APPROVAL OF THE LICENSED DESIGN

PROFESSIONALS FOR THE PROJECT. THESE MATERIALS MAY BE

PRINTED AND/OR TRANSFERRED ELECTRONICALLY SOLELY AS

NEEDED BY THE USER. BECAUSE CAD ELECTRONIC FILES AND

BIM (BUILDING INFORMATION MODELING ) FILES CAN BE

MODIFIED BY OTHER PARTIES, WITHOUT NOTICE OR INDICATION

OF SUCH MODIFICATIONS, MODIFICATION OF USG PRODUCT CAD

DRAWINGS IS THE SOLE RESPONSIBILITY OF THE DESIGN

PROFESSIONAL.

10/16/201500

1 OF 1

01

WALL

PENETRATION

DETAILS

WA

LL P

EN

ET

RA

TIO

N D

ET

AILS

FIR

E R

ES

IS

TA

NT

A

SS

EM

BLIE

S

US

G J21

33 R

EV

0

IS

SU

ED

10/16/2015

SEE DETAIL #1 NOTE #3 FOR FORMINGAND FIRE STOP MATERIAL EA SIDE TYP

CONTINUOUS BEAD OFGREEN GLUE

CONTINUOUS BEAD OFSEALANT

BLOCKING AS REQ., TYP

MECHANICAL DUCT W/CEILING DUMPER.REF.TO MECH DWG'S

1/2" GYP BD3" SOUNDPROOF STONE WOOL

INSULATION TO INFILL THEJOIST CAVITY

1/2" RESILIENT FURRINGCHANNEL @ 16" O.C.

FLOOR JOIST. SEESTRUCT

SEE DETAIL #1 NOTE #3 FORFORMING AND FIRE STOP

MATERIAL EA SIDE TYP

4 NOT IN SCALEFLOOR ASSEMBLY -FIRE DAMPER

FIRESTOP CEILING/FLOOR PENETRATION DETAIL F-C-3054NOT IN SCALE 2 FIRESTOP - WALL PENETRATION DETAIL -U605

NOT IN SCALE

3 BULK HEAD DETAILNOT IN SCALE 5 SHAFT DETAIL

NOT IN SCALE

3 NOT IN SCALE1HR FLOOR ASSEMBLY -RECESSED LIGHT UL DES U5011

Pena

tratio

n D

etai

ls

NOTES1. ALL AUTO GRAVITY DAMPER SHALL BE INSTALLED IN ALL AIR INTAKE AND EXHAUST VENTSPER IECC R403.52. THIS PROJECT IS REQUIRED TO SUBMIT AT FINAL INSPECTION A DUCT LEAKAGE TESTSHOWING A PASSING RATING OF < = 8 CFM PER 100 SF CONDITIONED FLOOR AREA AT APRESSURE OF 25 PASCAL. A WRITTEN REPORT OF THE RESULTS OF THE TEST SHALL BESIGNED BY THE PARTY CONDUCTING THE TEST AND PROVIDED TO THE CODE OFFICIAL.3. AIR HANDLERS SHALL HAVE MANUFACTURER DESIGNATION FOR LEAKAGE RATE OF 2%

Page 11: THE HART RESIDENCE

GSPublisherEngine 0.0.100.100

Drawn by DateLB 12.02.20

Checked by Date.

A3.3

The

Har

t Res

iden

ce64

09 4

th A

venu

eTa

kom

a Pa

rk M

aryl

and

2091

2

Written dimensions on these drawings shallhave precedence over scale dimensions.

Contractor shall verify and be responsible for alldimensions and conditions on the job and this

office must be notified of any variations from thedimensions and conditions.

© COPYRIGHT

10739 Tucker St #260Beltsville MD 20705

301.579.4563

W-2 TYPICAL WALLNON COMBUSTIBLE WALL

INTERIOR

W-3 TYPICAL EXTERIOR WALL

INTERIOREXTERIOR

W-4 TYPICAL INTERIOR WALL

EX 1/2" GYP BD

EX CMU WALL

2X6'S 16" OC

SIDING, TYP

ENGINEERED WOODFLOORING

FLOORING UNDERLAYMENT PERMANUF

NEW CONC SLAB

EX VAPOR BARRIER, VIF

EX COMPACTED GRAVEL

3/4" HWD FLOOR

3/4" T&G PLYWDSUBFLR

1/2" GYP BD

3/4" HWD FLOOR

3/4" T&G PLYWDSUBFLR

1/2" GYP BD

1/2" GWB EA SIDEW/MOISTURERESISTANT GWB @ WETLOCATIONS, TYP

2X4'S 16" OC

SOUNDPROOFINGCLIPS & DRYWALL

FURRING CHANNEL

3 1/2" BATT INSUL

EX PT 2" FURRSTRIPS 16" OC

F-2 1ST FLOOR ASSEMBLY F-3 FLOOR ASSEMBLY F-4 CEILING-ROOF ASSEMBLY

OUTSIDE

W-1 TYPICAL WALLNON COMBUSTIBLE WALL

INTERIOR

EX 1/2" GYP BD

EX CMU WALL

EX PT 2" FURRSTRIPS 16" OC

OUTSIDE

ENGINEERED WOODFLOORING

FLOORING UNDERLAYMENT PERMANUF

EX CONC SLAB

EX VAPOR BARRIER, VIF

EX COMPACTED GRAVEL

F-1 1ST FLOOR ASSEMBLY

1/2" GYP BD1" THK

PARGING

R5 RIGIDINSUL BTWNSTRIPS, TYP

R5 CONT WEATHERRESIST INSUL

R20 BATT INSUL

VERTICAL,TYP

R5 CONTWEATHER

RESISTINSUL

R5 RIGIDINSUL BTWNSTRIPS, TYP

Asse

mbl

y D

etai

ls

Page 12: THE HART RESIDENCE

GSPublisherEngine 0.0.100.100

Drawn by DateLB 11.18.20

Checked by Date.

S0.1

The

Har

t Res

iden

ce64

09 4

th A

venu

eTa

kom

a Pa

rk M

aryl

and

2091

2

Third

Flo

or P

lan,

Firs

t Flo

orPl

an_P

D1

4329

12.29.20

Written dimensions on these drawings shallhave precedence over scale dimensions.

Contractor shall verify and be responsible for alldimensions and conditions on the job and this

office must be notified of any variations from thedimensions and conditions.

© COPYRIGHT

10739 Tucker St #260Beltsville MD 20705

301.579.4563

Stru

ctur

al N

otes

GENERAL NOTESA) DESIGN LOADS FOR NEW WORK 1) FLOOR LIVE LOADS A) BEDROOM = 30 PSF B) LIVING AREAS = 40 PSF C) UNHABITABLE ATTICS WITHOUT STORAGE = 10 PSF D) UNHABITABLE ATTICS WITHOUT STORAGE = 20 PSF

2) ROOF SNOW LOAD A) Pg = 30 PSF B) Pf = 18.9 ;MIN PER DCMR = 30 PSF C) EXPOSURE = B D) Ce = 0.9 E) I = 1.0 F) Ct = 1.0 G) IN ADDITION TO THE FLAT ROOF SNOW LOAD STATED ABOVE, A SNOWLOAD PROVISION FOR DRAFTING SNOW AND SLOPED ROOF HAS BEEN PROVIDED IN ACCORDANCE WITH THE REQUIREMENTS OF THE INTERNATIONAL RESIDENTIAL CODE 2018, SECTION 1608.7

3) WIND LOAD A) BASIC WIND SPEED (3-SECOND GUST) , V = 115 MPH B) IMPORTANCE FACTOR = 1.0 C) EXPOSURE = B D) BUILDING CATEGORY = II

4) BRACED WALL PANEL CONSTRUCTION: WSP AND CS-WSP CONTINUOUS SHEATING STRUCTURAL WOOD PANEL PER THE REQUIREMENTS OF THE 2017 INTERNATIONAL RESIDENTIAL CODE SECTION R602.105) IMPOSED CONSTRUCTION LOADS IN EXCESS OF STATED DESIGN LOADS MUST BE APPROVED BY THE STRUCTURAL ENGINEER PRIOR TO THE IMPOSTION OF SUCH LOADS.6) THE STRUCTURE IS DESIGNED IN ACCORDANCE WITH THE INTERNATIONAL RESIDENTIAL CODE/2018

B) GENERAL1) THE GENERAL CONTRACTOR AND SUB-CONTRACTORS SHALL DETERMINE THE SCOPE OF THE STRUCTURAL WORK FROM THE CONTRACT DOCUMENTS TAKEN AS A WHOLE. THE STRUCTURAL DRAWINGS SHALL NOT BE CONSIDERED SEPARATE FOR PURPOSES OF BIDDING THE STRUCTURAL WORK. DUE CONSIDERATION SHALL BE GIVEN TO THE OTHER STRUCTURAL WORK OR WORK RELATED TO THE STRUCTURE, INCLUDING NECESSARY COORDINATION DESCRIBED OR IMPLIED BY THE ARCHITECTURAL, ELECTRIC, PLUMBING AND MECHANICAL DRAWINGS.2) SCALES NOTED ON THE DRAWINGS ARE FOR GENERAL INFORMATION ONLY. NO DIMENSIONAL INFORMATION SHALL BE OBTAINED BY DIRECT SCALING OF THE DRAWING.3) DETAILS, SECTIONS AND NOTES SHOWN ON THESE DRAWINGS ARE INTENDED TO BE TYPICAL AND SHALL APPLY TO SIMILAR CONDITIONS ELSEWHERE UNLESS OTHERWISE SHOWN OR NOTED.4) THE GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF ALL RESULTING REVISIONS TO THE STRUCTUAL SYSTEM AS A RESULT OF ACCEPTANCE OF CONTRACTOR PROPOSED ALTERNATIVES OR SUBSTITUTIONS.5) THE GENERAL CONTRACTOR (OR CONSTRUCTION MANAGER) SHALL SUBMIT SHOP DRAWINGS FOR ALL STRUCTURAL ELEMENTS SHOWN ON THE CONTRACT DOCUMENTS FOR APPROVAL. THE STRUCTURAL ENGINEER WILL NOT BE RESPONSIBLE FOR THE STRUCTURAL CERTIFICATION AND DESIGN OF THE PROJECT IF THE GENERAL CONTRACTOR FAILS TO OBTAIN APPROVAL OF THE SHOP DRAWINGS. SHOP DRAWINGS ARE REVIEWED AS A CONVENIENCE TO THE GENERAL CONTRACTOR AND ARE NOT A CONTRACT DOCUMENT. THE GENERAL CONTRACTOR SHALL STATE ON THE SHOP DRAWINGS THAT CONTRACT DOCUMENT REQUIREMENTS HAVE BEEN MET AND THAT ALL DIMENSIONS, CONDITIONS AND QUANTITIES HAVE BEEN REVIEWED AND VERIFIED AS SHOWN AND/OR CORRECTED ON THE SHOP DRAWINGS.6) THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING TEMPORARY BRACING AND SHORING, AS REQUIRED, TO ENSURE VERTICAL AND LATERAL STABILITY OF THE ENTIRE STRUCTURE OR PORTION THEREOF DURING CONSTRUCTION.7) ANY REQUIRED TEMPORARY SHORING SHALL BE IN CONFORMANCE WITH OSHA REGULATIONS. UNBRACED EXCAVATIONS SHALL BE SLOPED NO GREATER THAN (1.5) HORIZONTAL TO (1) VERTICAL8) TEMPORARY BRACING SHALL BE PROVIDED FOR ALL WALLS SUBJECT TO UNBALANCED BACKFILL. BRACE WALL PLUMB UNTIL STABILIZING ELEMENT ABOVE IS IN PLACE.9) ALL WALLS ARE DESIGNED AS LATERALLY BRACED BY THE FLOOR SYSTEMS. CONTRACTOR SHALL ENSURE THAT WALLS ARE ADEQUATELY BRACED DURING CONSTRUCTION.10) INFORMATION SHOWN REGARDING EXISTING CONDITIONS HAS BEEN OBTAINED BY LIMITED VISUAL OBSERVATIONS. AREAS NOT VISIBLE HAVE BEEN ASSUMED TYPICAL WITH OBSERVED EXISTING CONDITIONS.11.) THE CONTRACTOR SHALL MEASURE AND PROVIDE ALL DIMENSIONS, ELEVATIONS AND CONDITIONS AT THE JOB SITE PRIOR TO CONSTRUCTION AND THE SUBMISSION OF SHOP DRAWINGS AND SHALL NOTIFY THE ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES. VERIFICATIONS AND NOTIFICATION SHALL PROCEED PRIOR TO THE START OF WORK SO THAT ANY NECESSARY CHANGES CAN BE MADE WITHOUT DELAYING THE PROJECT SCHEDULE.

C) DEMOLITION1) ALL WORK SHALL BE IN GENERAL COMPLIANCE WITH THE INTERNATIONAL RESIDENTIAL CODE/20182) FURNISH ALL LABOR AND MATERIAL NECESSARY TO PERFORM THE DEMOLITION WORK IN A COMPLETED MANNER SUCH THAT NEW WORK CAN BE INSTALLED WITH MINIIMUM PREPARATION.3) CONTRACTOR SHALL INCLUDE IN THE SCOPE OF WORK ALL ASPECTS OF REQUIRED DEMOLITION, SHORING OF EXISTING STRUCTURE, STAGING THE REPAIR TASKS AND SCHEDULING THE WORK IN A MANNER APPROVED BY THE BUILDING MANAGEMENT, CLEAN UP AFTER PORTIONS OF WORK ARE PERFORMED AND CLEAN UP AFTER THE ENTIRE REPAIR IS COMPLETED.4) CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL TEMPORARY SHORING AND BRACING REQUIRED FOR DEMOLITION OPERATIONS. CONTRACTOR SHALL BE RESPONSIBLE FOR THE DESIGN OF AND PROCEDURES FOR THE REQUIRED TEMPORARY SHORING. TEMPORARY SHORING SHALL BE IN CONFORMANCE WITH OSHA REGULATIONS.5) THE CONTRACTOR SHALL TAKE PRECAUTIONS TO PREVENT DAMAGE OF THE EXISTING STRUCTURE. IN THE EVENT OF DAMAGE, CONTRACTOR SHALL PROVIDE TEMPORARY SHORING AND CONTRACT THE STUCTURAL ENGINEER FOR ASSESSMENT OF THE DAMAGE.6) SCHEDULE ALL WORK IN A CAREFUL MANNER WITH ALL NECESSARY CONSIDERATION FOR THE HOME OWNER. ANY DAMAGE TO PERSON OR PROPERTY AS A RESULT OF DEMOLITION AND RELATED WORK SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR.

D) FOUNDATION AND SLAB ON GRADE1) ESTIMATED ALLOWABLE SOIL BEARING PRESSURE FOR SHALLOW FOOTINGS IS 1500 PSF. BEARING CAPACITY SHALL BE FIELD DETERMINED BY A LICENSED GEOTECHNICAL ENGINEER PRIOR TO PLACEMENT OF CONCRETE. SHOULD UNSUIT ABLEMATERIAL BE ENCOUNTERED, FOOTING SHALL BE OVEREXCAVATED AND REPLACED WITH LEAN CONCRETE, F'c = 2000 PSI. BOTTOM OF ALL EXTERIOR FOOTINGS SHALL BE MINIMUM OF 2 FEET 6 INCHES BELOW EXTERIOR GRADE, UNLESS NOTED OTHERWISE.2) THE FOUNDATION FOR THE STRUCTURE HAS BEEN DESIGNED FOR THE FOLLOWING LATERAL EARTH PRESSURES: b) WALLS SUPPORTED TOP AND BOTTOM = 35 PCF3) ALL FOOTING EXCAVATIONS SHALL BE INSPECTGED BY THE BUILDING OFFICIAL PRIOR TO THE PLACING OF ANY CONCRETE. THE BUILDING OFFICIAL SHALL BE GIVEN NOTICE FOR THIS OBSERVATION.4) TOP OF FOOTINGS SHALL EXTEND TO ELEVATIONS SHOWN. SHOULD UNSUITABLE MATERIAL BE ENCOUNTERED, FOOTING SHALL BE OVEREXCAVATED AND REPLACED WITH LEAN CONCRETE, F'c = 2000 PSI.5) EXCAVATIONS FOR SPREAD FOOTINGS AND/OR CONTINUOUS FOOTINGS SHALL BE CLEANED AND HAND TAMPED TO A UNIFORM SURFACE.6) WALLS RETAINING EARTH BACKFILL HAVE BEEN DESIGNED FOR IN SERVICE LOADS ONLY. THE CONTRACTOR SHALL PROVIDE TEMPORARY SHORING DURING CONSTRUCTION. THE SHORING SHALL NOT BE REMOVED UNTIL THE SUPPORTING ELEMENTS ARE IN PLACE. THE CONCRETE IN THE WALLS AND SUPPORTING ELEMENTS HAS ATTAINED THE SPECIFIED 28 DAY COMPRESSIVE STRENGTH (Fc') AND COMPACTION OF THE BACKFILL HAS BEEN COMPLETED.7) SLAB ON GRADE SHALL BE UNDERLAID BY A MINIMUM OF 4 INCHES OF GRANULAR MATERIAL HAVING A MAXIMUM AGGREGATE SIZE OF 1.5 INCHED AND NOT MORE THAN 10% OF MATERIAL PASSING THROUGH A NO. 4 SIEVE. PRIOR TO PLACING THE GRANULAR MATERIAL THE FLOOR SUBGRADE SHALL BE PROPERLY COMPACTED, PROOFROLLED, FREE OF STANDING WATER, MUD, ORGANIC MATERIAL AND FROZEN SOIL BEFORE PLACEMENT OF THE CONCRETE, A VAPOR BARRIER SHALL BE PLACED ON TOP OF THE GRANULAR MATERIAL.

G) CAST-IN-PLACE CONCRETE1) ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH ACI 301, ACI318 AND ACI 302.2) CAST IN PLACE CONCRETE SHALL HAVE A MINIMUM 28-DAY COMPRESSIVE STRENGTH F'c AS FOLLOWS: a) SLAB-ON-GRADE AND FOOTINGS = 3000 PSI3) CEMENT SHALL COMPLY WITH A STM C150, TYPE I OR TYPE II.4) THE USE OF FLY ASH/OR GROUND GRANULATED BLAST-FURNANCE SLAG IS NOT PERMITTED.5) CONCRETE SLUMP SHALL 4 INCHES +/-1 INCH.6) ALL CONCRETE EXPOSED TO WEATHER SHALL HAVE A MINIMUM AIR ENTRAINMENT OF 6% +/-1.5%7) CONCRETE REINFORCEMENT BARS SHALL CONFORM TO ASTM A615, GRADE 60. REINFORCEMENT BARS SHALL NOT BE TACK WELDED, WELDED, HEATED OR CUT UNLESS INDICATED ONTHE CONTRACT DOCUMENTS OR APPROVED BY THE STRUCTURAL ENGINEER.8.) PROVIDED WELDED WIRE FABRIC 6 X6 - W1.4X W1.4 IN ALL SLAB ON GRADE. ALL WRE FABRIC SHALL CONFORM TO ASTM .A185. ALL MESH EDGES SHALL LAP A MINIMUM OF 2 SQUARES.9) MINIMUM CONCRETE COVER BETWEEN FACE OF REINFORCING BAR AND FACE OF CONCRETE SHALL BE AS FOLLOWS: a) CONCRETE CAST AGAINST EARTH = 3" b) FORMED CONCRETE EXPOSED TO WEATHER OR EARTH = 2"10) DETAILING OF CONCRETE REINFORCEMENT BARS AND ACCESSORIES SHALL CONFORM TO THE RECOMMEDATIONS OF ACI 315 'DETAILS AND DETAILING OF CONCRETE REINFORCEMENT AND ACI SP-68 'DETAILING MANUAL'. PLACING OF REINFORCING BARS SHALL CONFORM TO THE RECOMMENDATIONS OF ACI 315R 'MANUAL OF ENGINEERING AND PLACING DRAWINGS FOR REINFORCED CONCRETE STRUCTURES" AND CRSI 'MANUAL OF STANDARD PRACTICE".11) REINFORCEMENT DESIGNATED AS "CONTINUOUS" SHALL LAP 36 BAR DIAMETERS AT SPLICES UNLESS NOTED OTHERWISE.

H) STRUCTURAL STEEL1) STRUCTURAL STEEL ROLLED SHAPES AND PLATES SHALL CONFORM TO ASTM A36.2) ALL PIPE COLUMNS SHALL CONFORM TO ASTM A53 TYPES E OR S, GRADE B, STANDARD PIPE TO BE UNLESS NOTED OTHERWISE.3) ALL ANCHOR BOLTS SHALL BE ASTM A307 UNLESS OTHERWISE NOTED.4) ALL WORK SHALL COMPLY WITH THE AISC ASD (NINTH EDITION) CODE "CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES" EXCEPT THAT PARAGRAPH 4.2.1 SHALL BE DELETED.5) STRUCTURAL STEEL SHOP DRAWINGS SHALL BE SUPERVISED BY A PROFESSIONAL ENGINEER REGISTERED IN THE DISTRICT OF COLUMBIA AND SHALL INCLUDE DETAILS OF CUTS, CONNECTIONS, HOLES, AND OTHER PERTINENT DATA. INDICATE WELDS BY STANDARD AWS 2.1 SYMBOLS SHOWING SIZE, LENGTH AND TYPE OF EACH WELD, SHOP DRAWINGS SHALL BE SUBMITTED TO THE ARCHITECT FOR APPROVAL.6) NO FABRICATIONS SHALL PROCEED PRIOR TO SHOP DRAWINGS APPROVAL.7) NO OPENINGS IN BEAMS OR COLUMNS ARE PERMITTED WITHOUT ENGINEER'S WRITTEN APPROVAL.8) SPLICING OF STRUCTURAL STEEL MEMBERS WHERE NOT DETAILED ON THE CONTRACT DOCUMENTS IF PROHIBITED WITHOUT PRIOR APPROVAL OF THE STRUCTURAL ENGINEER AS TO LOCATION, TYPE OF SPLICE AND CONNECTION TO BE MADE.9) THE CONTRACTOR SHALL NOTIFY THE STRUCTURAL ENGINEER OF ANY MISFABRICATED STRUCTURAL STEEL PRIOR TO ERECTION OF SAME.10) ONE 1.5 MIL COAT OF SHOP PAINT SHALL BE APPLIED TO ALL STRUCTURAL STEEL WITH THE EXCEPTION OF AREAS TO BE WELDED.11) STRUCTURAL STEEL CAST INTO OR IN CONTACT WITH CONCRETE SHALL NOT BE PAINTED.12) PROVIDE A MINIMUM BEARING LENGTH OF 6 INCHES FOR ALL BEAMS SUPPORTED ON MASONRY.13) PROVIDE STANDARD AISC ANGLE WALL ANCHORS FOR STEEL BEAMS SUPPORTED IN MASONRY POCKETS.14) GROUT SHALL BE NON-SHRINKABLE, NON-METALLIC CONFORMING TO ASTM C827, AND SHALL HAVE A SPECIFIED COMPRESSIVE STRENGTH AT 28 DAYSOF 5000 PSI. PREGROUTING OF BASE PLATES WILL NOT BE PERMITTED.

FOUNDATION DRAINAGE1. DAMPROOFING SHALL CONSIT OF A BITUMINOUS MATERIAL, 3LBS PER SQ YARD OF ACRYLIC MODIFIED CEMENT, 1/8 COAT OF SURFACE-BOUNDINGMORTAR COMPLYING WITH ASTM C 887, ANY OF THE MATERIALS PERMITTED FOR WATERPROOFING BY IBC SECTION 1805.3.2 OR OTHER APPROVEDMATERIALS.2. CONTRACTOR SHALL ROUGHEN JOINT AT CMU WALL TO FOOTING INTERFACE OR PROVIDE 1" X 4" KEY WAY ALONG THE ETNIER LENGTH OF THE CMUWALL.3. A FOUNDATION DRAIN SHALL BE INSTALLED ALONG THE LENGTH OF THE CMU WALL FOOTING, ON THE EXTERIOR SIDE OF THE FOOTING, THAT CONSISTOF GRAVEL OR CRUSHED STONE CONTAINING NOT MORE THAN 10% MATERIAL THAT PASSES THROUGH A #4 SLEEVE. THE DRAIN SHALL EXTEND A MIN OF12" BEYOND THE OUTSIDE EDGE OF THE FOOTING, THE TOP OF THE DRAIN SHALL BE COVERED WITH A FILTER MEMBRANE FABRIC MATERIAL. THE TOP OFJOINTS OR THE TOP OF PERFORATIONS SHALL BE PROTECTED WITH A FILTER MEMBRANE FABRIC MATERIAL. THE DRAIN PIPE SHALL BE PLACED ON NOTLESS THAN 2" OF GRAVEL OR CRUSHED STOEN AND SHALL BE COVERED WITH NOT LESS THAN 6" OF THE SAME MATERIAL. THE DRAIN SHALL DISCHARGEBY GRAVITY INTO AN APPROVED DRAINAGE SYSTEM.4. ALL FOUNDATION DRAIN PIPES SHALL BE PERFORATED SOLID WALL SCHEDULE 40 PVC WITH SOLVENT JOINTS WRAPPED IN GEOTEXTILE FABRIC WITH ASTONE DUST BED AND COVER.

PRE-FABRICATED WOOD TRUSSES1. TRUSS SUPPLIER SHALL FABRICATE, SUPPLY AND ERECT WOOD TRUSSES AS SHOWN ON THE DRAWINGS AND AS SPECIFIED. INCLUDE ANCHORAGE,BLOCKING, CURBING, MISC FRAMING, BRACING AND ALL CONNECTIONS MATERIALS2. TRUSS MANUFACTURER SHALL FURNISH DESIGN DRAWINGS BEARING THE SEAL AND REGISTRATION NUMBER OF THE DESIGN PROFESSIONALLICENSED IN THE STATE WHERE THE TRUSSES ARE TO BE INSTALLED. DRAWINGS SHALL BE APPROVED BY THE ENGINEER PRIOR TO FABRICATION3. LUMBER USED SHALL BE INDENTIFIED BY THE GRADE MARK OF A LUMBER INSTECTION BUREAU OR AGENCY APPROVED BY THE BOARD OF REVIEW OFTHE AMERICAN LUMBER STANDARDS COMMITTEE4. STEEL FOR CONNECTOR PLATES SHALL MEET OR EXCEED ASTM A446 - SPECIFICATIONS FOR SHEET STEEL, ZINC COATED BY THE HOT DIPPEDPROCESS.5. TRUSSES SHALL BE FABRICATED IN COMPLIANCE WITH REQUIREMENTS IN NDSMPCWTC, TPI6. TRUSSES SHALL BE HANDLED DURING FABRICATION, DELVIERY AND AT THE JOBSITE SO AS NOT TO SUBMJECTED TO EXCESSIVE LATERAL BENDING,ERECTION SHALL BE IN ACCORDANCE WITH BCS1-2006. TRUSSES MUST BE SET AND SECURED LEVEL AND PLUMB AND IN CORRECT LOCATION PERMANUF. CUTTING AND ALTERING OF TRUSSES IS NOT PERMITED7. BRACE TRUSSES SUFFICEIENTLY DURING ERECTION TO RPEVEN TTOPPLING OR DOMINOING. INSTALL ALL BRACING BEFORE PLACING CONENTRATEDLOAD ON TRUSSES8. LOADS (SHALL NOT EXCEED) FLOOR TRUSS L/480 SUPPORTING CERAMIC TILE L/720 ROOF TRUSS L/360 UP TO MAX 0.8. TOTAL LOAD DEFLECTION SHALL BE LIMITED TO L/240. PROVIDE SIMPSON H2.5A OR EQV HURRICANE CLIP AT EACH TRUSS BEARING POINTE. GIRDER TRUSS SIMPSON H6 OR EQV9. TRUSS DESIGNER SHALL DESIGN FOR LOADING FROM SPRINKLER HANDLERS. CONTRACTOR TO COORDINATE SPRINKLER PIP HANGER SPACING ANDINSTALLATION10. ADD EXTRA FLOOR TRUSS UNDER FULL HEIGHT WALLS WHERE WALL EXTENDS MORE THAN HALF THE SPAN OF THE TRUSS

Page 13: THE HART RESIDENCE

GSPublisherEngine 0.0.100.100

Drawn by DateLB 11.18.20

Checked by Date.

S1.0

The

Har

t Res

iden

ce64

09 4

th A

venu

eTa

kom

a Pa

rk M

aryl

and

2091

2

Seco

nd F

loor

Win

d B

raci

ng P

lan

4329

12.29.20

Written dimensions on these drawings shallhave precedence over scale dimensions.

Contractor shall verify and be responsible for alldimensions and conditions on the job and this

office must be notified of any variations from thedimensions and conditions.

© COPYRIGHT

10739 Tucker St #260Beltsville MD 20705

301.579.4563

30" CS-WSP

48" C

S-W

SP

30" CS-WSP

48" C

S-W

SP48

" CS-

WSP

36" C

S-W

SP

48" C

S-W

SP48

" CS-

WSP

1.S1.0

Second Floor Wind Bracing Plan1/4" = 1'-0"

NOTES1. BRACED WALL PANEL, CS-WSP: EXTERIOR SHEATHING SHALL BE NAILEDWITH 8D NAILS AT 6" OC EDGES, 12" OC FIELD. SHEATHING EDGES SHALLBE BLOCKED. STRUCTURAL PANEL SHEATHING SHALL BE USED ON ALLSHEATHABLE AREAS OF THE BRACED WALL LINE.

2. WALL SHEATHING SHALL BE MIN 1/2" STRUCTURAL GRADE PLYWOOD

Page 14: THE HART RESIDENCE

GSPublisherEngine 0.0.100.100

Drawn by DateLB 11.18.20

Checked by Date.

S1.1

The

Har

t Res

iden

ce64

09 4

th A

venu

eTa

kom

a Pa

rk M

aryl

and

2091

2

Foun

datio

n Pl

an, F

ram

ing

Plan

@Fi

rst F

loor

4329

12.29.20

Written dimensions on these drawings shallhave precedence over scale dimensions.

Contractor shall verify and be responsible for alldimensions and conditions on the job and this

office must be notified of any variations from thedimensions and conditions.

© COPYRIGHT

10739 Tucker St #260Beltsville MD 20705

301.579.4563

1S2.2

1S2.2

1S2.2

3S2.2

14'-81/2" 8" 6'-111/4" 7'-83/4" 8"

10"

29'-4

"8"

16'-3

5/8"

30'-0

"

16'-0"

46'-3

5/8"

30'-81/2"

B/S2.1 B/S2.1

EX FOUND WALL,TYP. VIF

EX CONT CONCFTG, TYP, VIF

8" CMU WALL,TYP

CONT CONC FTG,TYP

DRAIN PIPE AT FTG,TYP

18" dia X 30" CONCPIER

DN

NEW 4" CONC SLAB ONGRADE W/6X6 W1.4 -

W1.4 WWM ON 2" RIGIDINSUL OVER 6 MIL

VAPOR BARRIER OVER4" COMPACTED

GRAVEL

EX SLAB ON GRADE, VIF

2S2.2

A/S2

.1A/

S2.1

6'-91/4"

16'-0"

29'-1

17/8"

46'-3

5/8"

30'-81/2"

16'-3

5/8"

14'-81/2"

STAIRCASEAREA

2X6'S 16" OC@ LANDING

PT 2X12 STRINGER,TYP @ 3 LOCATIONS

PT 4X4 POST, TYP

STL LINTEL

EX LINTELTO

REMAIN,VIF

EX LINTELTO

REMAIN,VIF

EX LINTELTO

REMAIN,VIF

EX LINTELTO

REMAIN,VIF

STL LINTEL

STL

LIN

TEL

TJI 9

1/2

" 16"

OC

(230

)

1 1/

7" T

J R

IM B

D

1 1/

7" T

J R

IM B

D

EX L

INTE

LTO

REM

AIN

,VIF

(2) 2X6'S

(3) 2

X6'S

SISTER (1) 1 3/4 X 5 1/2" LVLEVERY OTHER EX JOIST

EX 2

X6'S

16" O

C

PT (2) 2X8

PT 2X6'S 16" OC

see

hdr

sche

dule

see

hdr

sche

dule

see

hdr

sche

dule

see

hdr

sche

dule

1.S1.1

Foundation Plan1/4" = 1'-0"

2.S1.1

Framing Plan @ First Floor1/4" = 1'-0"

Page 15: THE HART RESIDENCE

GSPublisherEngine 0.0.100.100

Drawn by DateLB 11.18.20

Checked by Date.

S1.2

The

Har

t Res

iden

ce64

09 4

th A

venu

eTa

kom

a Pa

rk M

aryl

and

2091

2

Fram

ing

Plan

@ 2

nd F

loor

, Roo

fFr

amin

g Pl

an

4329

12.29.20

Written dimensions on these drawings shallhave precedence over scale dimensions.

Contractor shall verify and be responsible for alldimensions and conditions on the job and this

office must be notified of any variations from thedimensions and conditions.

© COPYRIGHT

10739 Tucker St #260Beltsville MD 20705

301.579.4563

14'-81/2"

11'-17/8"

3" BEARING EAEND, TYP

3" BEARING EAEND, TYP

VAULTED CEILING INTHIS AREA

(SEE SECTION CUT)

(2) 1 3/4 X 9 1/2" LVL (UPSET)

EX HDR TOREMAIN, VIF

EX HDR TOREMAIN, VIF

SCISSORTRUSSES THIS

AREA

(2) 1 3/4 X 7 1/2" LVL

see

hdr

sche

dule

see hdrschedule

see hdrschedule

see

hdr

sche

dule

see

hdr

sche

dule

see

hdr

sche

dule

see

hdr

sche

dule

see

hdr

sche

dule

see

hdr

sche

dule

see

hdr

sche

dule

1'-0" 16'-0" 1'-0"

1'-0

"46

'-35/

8"1'

-0"

.

1'-0

"16

'-35/

8"1'

-0"

1'-0" 30'-81/2" 1'-0"

OUTRIGGERS 16" OC, TYP

PRE ENGINEEREDGIRDER TRUSS

OUTRIGGERS 16" OC, TYP

PRE ENGINEEREDOVERBULD TRUSSES

24" OC, TYP

OH OH

OH

OH

PRE ENGINEERED SCISSOR TRUSSES 24" OC

SIMPSON HTU TRUSS HANGER. SEE TRUSSENGINEER FOR SPECS

OH

OH

OHOH

EX RAFTERS 16" OC, VIF

1.S1.2

Framing Plan @ 2nd Floor1/4" = 1'-0"

2.A1.1

Roof Framing Plan1/4" = 1'-0"

Page 16: THE HART RESIDENCE

GSPublisherEngine 0.0.100.100

Drawn by DateLB 12.02.20

Checked by Date.

S2.1

The

Har

t Res

iden

ce64

09 4

th A

venu

eTa

kom

a Pa

rk M

aryl

and

2091

2

Written dimensions on these drawings shallhave precedence over scale dimensions.

Contractor shall verify and be responsible for alldimensions and conditions on the job and this

office must be notified of any variations from thedimensions and conditions.

© COPYRIGHT

10739 Tucker St #260Beltsville MD 20705

301.579.4563

S2.2S2.2

S2.2

2'-0

"8'

-0"

8'-4

"

9'-0

1/2"

8'-4

"

1'-0

1/2"

PROVIDE COLLARTIES AT RAFTERS16" OC, TYP

F2/

A3.3

F4/

A3.3 F3

/A3

.3

F2/

A3.3

W2/A3.3

W1/A3.3

W3/A3.3

W1/A3.3

TOP

EX 2ND FL

EX 1ST FL

TOP

2ND FL

1ST FL

M. BEDROOM

BED #2

HALL

HALLDEN

OPEN STAIR

S2.2

S2.2

S2.2

8'-0

"1'

-01/

2"8'

-4"

W1/A3.3

W2/A3.3

F2/

A3.3

F4/

A3.3

W3/A3.3

W3/A3.3

F5/

A3.3

TOP

2ND FL

1ST FL

AS2.1

Section Cut3/8" = 1'-0"

BS2.1

Section Cut3/8" = 1'-0"

Sect

ion

Cut

, Det

ails

Page 17: THE HART RESIDENCE

GSPublisherEngine 0.0.100.100

Drawn by DateLB 11.18.20

Checked by Date.

S2.2

The

Har

t Res

iden

ce64

09 4

th A

venu

eTa

kom

a Pa

rk M

aryl

and

2091

2

Third

Flo

or P

lan

4329

12.29.20

Written dimensions on these drawings shallhave precedence over scale dimensions.

Contractor shall verify and be responsible for alldimensions and conditions on the job and this

office must be notified of any variations from thedimensions and conditions.

© COPYRIGHT

10739 Tucker St #260Beltsville MD 20705

301.579.4563

6S2.2

DETAIL: @ GUARD RAIL CONSTRUCTIONNTS

4S2.2

DETAIL: @ RAILING (RAIL OUT)NTS

5S2.2

DETAIL : @ DECK STAIRNTS

3S2.2

DETAIL: PIER FOOTINGNTS

8S2.2

DETAIL: @ INT STAIRSNTS

7S2.2

DETAIL:DECK-TO-RIM POINTNTS1

S2.2DETAIL: FOUND WALL

NTS

9S2.2

DETAIL : @ TRUSS EAVENTS

2S2.2

DETAIL: CONC STAIRNTS

10S2.2

DETAIL: @ WINDOW WELLNTS

2 1/

2"3'

-0"

7"

10"

18"

3'-0

"1"

73/4"

10"

BEAM SUPPORT. VERIFY W/FRAMINGPLANS BEAM SIZES

SIMPSON LPC4Z POST CAP.SEE MANUF. FOR ADDITIONAL DTLS.

SIMPSON LUS210Z JOIST HANGERS

4X4 PTD GUARD RAIL POST

PRESSURE TREATED DECKING

SIMPSON HD2AHDG W/(2)5/8" GALV. THRU BOTS W/WASHERS

THRU GUARD RAIL & (2) 5/8" GALV. THRU2X8 JOIST. PROVIDE @ ALL GUARD RAIL

LOCATIONS

SIMPSON DPPC4BK POST CAP

2X4 PTD BEVELED RAIL CAP

2X4 PTD BOTTOM ROUTED OUTFOR PICKETS & BEVELED EACHWAY

2X2 PTD PICKETS @ 5" OC MAX.

2X10'S @ 16" OC

4X4 PTD POST

PT JOIST. SEE FRAMING FOR MOREINFO

PT WOOD DECKING

2X12 NOTCHEDCARRIAGE

2X10 HEADER JOIST @ TOPOF STAIR CARRIAGE NAILED TODOUBLE 2X'S TOP & BTM. W/SIMPSON AS5Z @ CORNERS

PT 2x12 NOTCHED CARRIAGE

MAINTAIN AIR GAP BTWNCARRIAGE & CONCRETESURFACE

STEEL ANGLE LAGGED TOCONC & STAIR CARRIAGE

PT WOOD DECKING

SIMPSON TA9Z/TA10ZSTAIRCASE ANGLE. TIES

STAIR TREAD TO STRINGER

24" X 12" THK CONT CONCFT'G W/(3) #4 REBAR

DBL JOIST. SEE FRAMING FORMORE INFO

SAWN END OF POST FIELDTREATED W/ WATERREPELLANT PRESERVATIVE

BOTTOM OF PIER HOLEMUST NOT CONTAIN ANYLOOSE DIRT

SLOPE GRADE FORDRAINAGE

GRADE

#3 TIES @ 6" OC

4 #5 VERTICAL

SIMPSON BASE COLUMN. SEEMANUF. FOR SPECS

PT POST. SEE STRUCT DWGSFOR POST SIZES

HANDRAIL 30" TO 34" ABOVENOSING AS REQ'D ON AT LEAST

ONE SIDE OF STAIRS MIN. HEADROOM6'-8" PER CODE.

3/4 T&G SUBFLR

NAILER

OAK TREAD

FULL OAK STRINGER

1/2 GYP BD

TRIM

PT JOIST @ 16" OC

LEDGER BD ATTACHED TO EXIST'GRIM JOIST W/ LAG SCREWS. SEESTRUCTURAL FOR MORE INFO

FLASHING ACROSS ENTIREWALL WHERE DECK MEETS

2X6 SOLE PLATE

2X6'S @ 16" O.C. W/R20 BATT INSULATION 1/2" GYP. BD.

BACKFILL W/RIVER ROCK AGAINSTWALL

4" PERFORATED DRAIN SET INGRAVEL

FINISHED FLOOR TBD

SLOPED GRADE

1/2" CEMENT PARGINGW/BITUM. PAINT

8" CMU FOUNDATIONWALL

BOND BEAM W/#4 HORIZONTAL REBAR @ TOPCOURSE

1" EXPANSION JOINT

3/4" T&G PLYWD SUBFLR.

WOOD SIDING

RIM JOIST

PT 2X8 MUDSILL

#5 VERTICAL REBAR @32" OC

NEW 4" CONC SLAB ON GRADE W/6X6 W1.4 -W1.4 WWM ON 2" RIGID INSUL OVER 6 MILVAPOR BARRIER OVER 4" COMPACTEDGRAVEL

24" x 24" x 12" THK CONC. FT'G W (3) #5 REBAR

R10 CONT RIGID INSUL

2X4 LAID FLAT FURRING STRIPS 16" OC, TYP

NEW 4" CONC SLAB ONGRADE W/6X6 W1.4 -W1.4WWM ON 2" RIGID INSUL

OVER 6 MIL VAPORBARRIER OVER 4"

COMPACTED GRAVEL

REINFORCEDCONCRETE STAIR

W/ (1) #4 REBAR @NOSING

2X6'S @ 16" OC W/ R20 BATT INSUL

1/2" GYP BD

(2) 2X6 TOP PLATE

CLOSED CELL FOAM INSUL = R49

SIMPSON HURRICANE TIE @ EA. TRUSS

WOOD SIDING

1/2" GYP BD

15# ROOFING PAPER

5/8" PLYWOOD SHEATHING

FLASHING

VENTILATION SPACE

ASPHALT SHINGLES

PRE ENGINEERED TRUSSES @ 24" OC

SLOPED GUTTER

1/2" PLYWD SOFFIT W/CONT.VINYL VENT SCREEN

CONTINUOUS FASCIA

EX CONC SLAB ON GRADE, VIF

EX FOUND WALL, VIF

EX CONT FTG, VIF

EXPANSION JOINT, TYP

R5 CONT INSUL/SHTG, TYP

1/2" GYP BD

PT DECK'G

R5 CONT INSUL/SHTG

GRADE

METAL EGRESS WELLW/INTEGRATED

LADDER.

EXTEND DRAIN TO DRAIN TILE

4" PERF. DRAIN TILESET IN GRAVEL @ FTG. BASE

COVER DRAIN TILE W/6" OF WASHEDGRAVEL OR CRUSHED ROCK

RIS

ERM

AX

TREADMAX

Det

ails

Page 18: THE HART RESIDENCE

GSPublisherEngine 0.0.100.100

Drawn by DateLB 12.02.20

Checked by Date.

M0.1

The

Har

t Res

iden

ce64

09 4

th A

venu

eTa

kom

a Pa

rk M

aryl

and

2091

2

Written dimensions on these drawings shallhave precedence over scale dimensions.

Contractor shall verify and be responsible for alldimensions and conditions on the job and this

office must be notified of any variations from thedimensions and conditions.

© COPYRIGHT

10739 Tucker St #260Beltsville MD 20705

301.579.4563

47 Q

Stre

et N

EW

ashi

ngto

n, D

C 2

0012

.

Drawn by DateLB 06.24.15

Checked by Date.

Drawing Scale

M1.0

Axo

nom

etric

Vie

w -

Sout

hwes

t Vie

w

Written dimensions on these drawings shallhave precedence over scale dimensions.

Contractor shall verify and be responsible for alldimensions and conditions on the job and this

office must be notified of any variations from thedimensions and conditions.

© COPYRIGHT

10739 Tucker St #260Beltsville MD 20705

301.579.4563

2012

2012

666

3.53.53.5

NOTES:

1. METALLIC FLEXIBLE DUCTWORK SHALL BE ATTACHED USING A MIN OF THREE #8 SHEET METAL SCREWS EQUALLY SPACEDAROUND THE DUCTWORK CIRCUMFERENCE. DUTWORK LARGER THAN 12" SHALL HAVE A MIN OF FIVE #8 SHEET METALSCREWS. SCREWS SHALL BE LOCATED AT LEAST 1" FROM THE DUCTWORK END.

2. NON-METALLIC FLEXIBLE DUCTWORK SHALL BE SECURED TO THE SLEEVE OR COLLAR USING A DRAW BAND. IF THEDUCTWORK COLLAR EXCEEDS 12", THE DRAW BAND MUST BE POSITIONED BEHIND A BEAD ON THE METAL COLLAR.

3. INSULATION AND VAPOR BARRIERS PRESENT ON THE FACTORY-FABRICATED DUCTWORK SHALL BE FITTED OVER THECORE CONNECTION AND SHALL BE SUPPLEMETALLY SECURED WITH A DRAW BAND.

4. FLEXIBLE DUCTWORK SEALING SHALL BE A CLASS 'B' SEAL FOR LOW PRESSURE DUCTWORK.

5. SUPPORT SYSTEM SHALL NOT DAMAGE OR CAUSE OUT OF ROUND SHAPE

6. FLEXIBLE DUCTWORK SHALL BE A MAX OF 8'-0" IN LENTH AND SHALL NOT BE USED AS AN ELBOW

7. MECHANICAL SYSTEM PIPING CAPABLE OF CARRYING FLUIDS ABOVE 105 °F (41 °C) OR BELOW 55 °F (13 °C) SHALL BEINSULATED TO A MIN OF R-3

8. PIPING INSULATION EXPOSED TO THE WEATHER SHALL BE PROTECTED FROM DAMAGE, INCLUDING THAT CAUSED BYSUNLIGHT, MOISTURE, EQUIPMENT MAINTENANCE, AND WIND, AND SHALL PROVIDE SHIELDING FROM THE SOLAR RADIATIONTHAT CAN CAUSE DEGRADATION OF THE MATERIAL. ADHVESIVE TAPE SHALL NOT BE PERMITTED.

9. INSULATION FOR HOT WATER PIPE WITH A MINIMUM THERMAL RESISTANCE (R-VALUE) OF R-3 SHALL BE APPLIED TO THEFOLLOWING: 1. PIPING LARGER THAN 3/4-INCH NOMINAL DIAMETER. 2. PIPING SERVING MORE THAN ONE DWELLING UNIT. 3. PIPING FROM THE WATER HEATER TO KITCHEN OUTLETS. 4. PIPING LOCATED OUTSIDE THE CONDITIONED SPACE. 5. PIPING FROM THE WATER HEATER TO A DISTRIBUTION MANIFOLD. 6. PIPING LOCATED UNDER A FLOOR SLAB. 7. BURIED PIPING. 8. SUPPLY AND RETURN PIPING IN RECIRCULATION SYSTEMS OTHER THAN DEMAND RECIRCULATION SYSTEMS. 9. PIPING WITH RUN LENGTHS GREATER THAN THE MAXIMUM RUN LENGTHS FOR THE NOMINAL PIPE DIAMETER GIVEN IN TABLE 403.4.2.

ALL REMAINING PIPING SHALL BE INSULATED TO AT LEAST R-3 OR MEET THE RUN LENGTH REQUIREMENTS OF TABLER403.4.2.

Mec

hani

cal H

VAC

Not

es

Page 19: THE HART RESIDENCE

GSPublisherEngine 0.0.100.100

The

Har

t Res

iden

ce64

09 4

th A

venu

eTa

kom

a Pa

rk M

aryl

and

2091

2

Drawn by DateLB 12.02.20

Checked by Date.

M1.1

Written dimensions on these drawings shallhave precedence over scale dimensions.

Contractor shall verify and be responsible for alldimensions and conditions on the job and this

office must be notified of any variations from thedimensions and conditions.

© COPYRIGHT

10739 Tucker St #260Beltsville MD 20705

301.579.4563

1

(N)3/4" GAS SERVICEGAS LOAD = 151.0 MBHGAS METER BY LOCAL UTILITY

(N)GAS FURNACE60.0 MBH

BASEMENT

FIRSTFLOOR

SECONDFLOOR

(N)GAS WATER HEATER38.0 MBH

(N)GAS STOVE53.0 MBH

ROOF

NOTE:

GAS PIPING IS BASED ON 2012 IFGC SECTION 402.4 (2)

TOTAL PIPING LENGTH = 50'-0"CONNECTED LOAD = 151.0 MBH

INLET PRESSURE = LESS THAN 2 PSIPRESSURE DROP = 0.5 PSISPECIFIC GRAVITY = 0.60

SCALE: N.T.S.M1.11 EX GAS RISER DIAGRAM - GAS

(N)3/4"GAS98.0 MBH

(N)1/2"GAS60.0 MBH

(N)1/2"GAS38.0 MBH

(N)1/2"GAS60.0 MBH

(N)1/2"GAS53.0 MBH

(N)1"GAS151.0 MBH

(N)1"GAS151.0 MBH

NOTE:

THE CONTRACTOR SHALL VERIFY THE INLETPRESSURE WITH THE GAS COMPANY PRIOR TOPERFORMING ANY GAS WORK .

.

TEMPEREDWATER(105°F)

C

CW

HW(120°F)

M

H

TO FIXTURES

LUBRICATED PLUG COCK

G

6" LONG DIRT LEG

DRAIN PAN

CW

TO IFXTURES

FLOOR

DRAIN VALVE WITH THREADEDHOSE CONNECTION DRAIN TODRAIN PAN

UNION-TYPICAL

A.S.M.E. RATED TEMPERATUREAND PRESSURE RELIEF VALVE.PIPE DISCHARGE FULL SIZE TODRAIN PAN

VACUUM RELIEF WATTS NO.36A,3|4"

EXPANSION TANKWATTS DET-5-M1

FLOORDRAIN

HW

SCALE: N.T.S.M1.1

D GAS WATER HEATER PIPING DETAIL TYP

4"FLUE VENT PIPETHROUGH WALL

SCALE: N.T.S.M1.1

A

TYPICAL TEMPERED WATERCONNECTION DETAIL

FLASHING, REFERTO ARCHITECTURALDRAWINGS

TYPE B GASVENT

METAL CAPWITH BIRDSCREEN

WALL SUPPORT

IN UNIT.

REFRIGERANT ISOLATION VALVES.

VALVES ARE FACTORY INSTALLEDNOT REQUIRED IF ISOLATION

FILTER/DRYER

SIGHT GLASS

CONDENSING UNITAIR COOLED DX

WHERE SPECIFIED

PREFABRICATED, EQUIPMENT

RIBBED NEOPRENE ISOLATORS

PAD OR EQUIPMENT CURB

SCALE: N.T.S.M1.1

E TYPICAL CONDENSING UNIT PIPING DETAIL

RETURN AIRGRILLE

FLEXIBLECONNECTOR TYPICAL

INSTALL A GALVANIZED STEEL DRIP PAN UNDERTHE UNIT A MINIMUM OF 2" DEEP AND 4"LARGER THAN THE UNIT WIDTH AND LENGTH.INSTALL A FLOAT SWITCH IN THE DRAIN PAN.

FURNANCE

SUPPLY AIR PLENUM WITH1" ACCOUSTICAL LINING

FLOOR

RETURN AIR PLENUMON BOTTON OF UNIT

TRAP

TRAPTRAP

1" CONDENSATEDRAIN, SPILL ONTOSPLASH BLOCK

SCALE: N.T.S.M1.1

C

VERITCAL FAN COIL UNIT WITHDRAIN PAN INSTALLATION DETAIL TYP

REFRIGERANT PIPINGTO HEAT PUMP ONGRADE

1" CONDENSATE PIPE

1" CONDENSATEDRAIN PAN PIPE

SUPPLY AIRDUCT WITH 1"ACCOUSTICALLINING

30"x22"

FILTER SECTION

COOLINGCOIL

4"FLUE VENT PIPETHROUGH EXTERIORWALL

SCALE: N.T.S.M1.1

B

GAS VENT THROUGHWALL DETAIL TYP

Mec

hani

cal G

as N

otes

1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE REQUIREMENTS OF THE 2017 INTERNATIONAL FUEL GAS

CODE, REGULATIONS OF LOCAL AUTHORITIES HAVING JURISDICTION AND THE OWNERS INSURANCE

UNDERWRITER.

2. FURNISH AND INSTALL ALL LABOR, MATERIAL, AND EQUIPMENT AND SERVICES NECESSARY FOR COMPLETE AND

SAFE INSTALLATION OF THE PLUMBING SYSTEM(S) INDICATED ON THE DRAWINGS AND NOTED IN THE

SPECIFICATIONS HEREINAFTER.

3. OBTAIN AND PAY FOR ALL INSPECTIONS, LICENSES, PERMITS AND APPROVALS REQUIRED BY GOVERNING

AUTHORITIES AND INSTALL ALL WORK IN COMPLIANCE THEREOF.

4. THESE DRAWINGS ARE CONSIDERED DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENT OF WORK AND

SYSTEMS. ALL PIPING AND SYSTEMS SHOWN SCHEMATIC. IT IS NOT POSSIBLE TO INDICATE EVERY OFFSET, ELBOW,

UNION, VALVE, TRAP, ACCESS PANEL, ETC. THAT IS REQUIRED FOR A PROPER WORKING SYSTEM. NO ADDITIONAL

COST WILL BE ALLOWED FOR FITTINGS THAT ARE REQUIRED TO INSTALL THE ENTIRE GAS SYSTEM IN THE SPACE

PROVIDED AND NECESSARY FOR A COMPLETE WORKING SYSTEM.

5. REFER TO ARCHITECTURAL DRAWINGS TO VERIFY LOCATION OF EQUIPMENT, ETC.

6. CONTRACTOR SHALL EXAMINE ALL DRAWINGS RELATED TO THIS AND OTHER TRADES, AND SHALL BE FULLY

INFORMED AS TO THE EXTENT OF THIS CONTRACT AND OVERALL INCLUDED WORK. THE CONTRACTOR WILL BE

RESPONSIBLE FOR TRADE COORDINATION AND SHALL COMMUNICATE ADEQUATELY WITH ALL OTHER DISCIPLINES

AS REQUIRED TO MAKE CLEARANCE ALLOWANCES AS REQUIRED BY ALL TRADES TO AVOID INTERFERENCE OF

DISCIPLINES.

7. THE CONTRACTOR SHALL CONNECT ALL ITEMS OF EQUIPMENT FURNISHED BY OTHERS AND UNDER OTHER

SECTIONS OF THE SPECIFICATIONS, CONTRACTOR SHALL PROVIDE ALL ITEMS NECESSARY TO COMPLETE THE GAS

INSTALLATION.

8. PROVIDE ACCESS PANELS FOR ALL CONCEALED VALVES, ETC. PROVIDE UNIONS FOR ALL PIPING CONNECTIONS TO

EQUIPMENT. ALL EXPOSED PIPING AND FITTINGS SHALL BE CHROME PLATED.

9. QUALITY OF MATERIALS SHALL BE NEW, BEST OF THEIR RESPECTIVE KIND, FREE FROM DEFECTS..

10. PROVIDE ALL REQUIRED LABOR AND MATERIAL. REPAIR OR REPLACE DEFECTIVE WORK AS DIRECTED.

11. ALL VALVES AND ACCESSORIES SERVING EQUIPMENT SHALL BE INSTALLED TO ALLOW PROPER SERVICING AND/OR

REMOVAL WITHOUT DISCONNECTING ALL PIPING AND ACCESSORIES.

12. INSTALLATION OF EQUIPMENT, PIPING, WIRING, ETC., SHALL BE DONE IN NEAT AND WORKMANLIKE MANNER AND

SHALL CONFORM TO THE LATEST TRADE PRACTICES. WATER PIPING AND SANITARY DRAIN LINES SHALL BE RUN

CONCEALED IN WALL ABOVE CEILING OR BENEATH FLOOR WHEREVER, POSSIBLE. EACH FIXTURE SHALL BE

COMPLETE WITH ALL TRIM, ANGLE STOPS, ESCUTCHEONS, TRAPS AND TAIL PIECES. ALL EXPOSED TRIM SHALL BE

CHROME PLATED. ALL FIXTURES SHALL BE PROPERLY SUPPORTED AND INSTALLED. ATTACHMENTS SHALL BE OF

STRONG AND DURABLE NATURE.

13. CONNECTION OF DISSIMILAR PIPING MATERIALS SHALL BE MADE BY MEANS OF DI-ELECTRIC FITTINGS.

14. NATURAL GAS PIPING, 3" AND SMALLER, INTENDED FOR OPERATION AT PRESSURES LESS THAN 5 PSIG SHALL BE

ASTM A53, SCHEDULE 40, BLACK STEEL JOINED BY CLASS 150 SOCKET WELD FITTINGS EXCEPT THAT CLASS 150,

BANDED, BLACK MALLEABLE IRON, THREADED FITTINGS MAYBE USED AT VALVES AND EQUIPMENT CONNECTION.

PROVIDE CONDENSATION TRAPS WITH REMOVABLE CAPS AT ALL EQUIPMENT CONNECTIONS.

15. NATURAL GAS PIPING: SCHEDULE 40 BLACK STEEL PIPE (ASTM A53) WITH 150 PSI FITTINGS AND WELDED JOINTS.

GAS GENERAL NOTES

Page 20: THE HART RESIDENCE

GSPublisherEngine 0.0.100.100

The

Har

t Res

iden

ce64

09 4

th A

venu

eTa

kom

a Pa

rk M

aryl

and

2091

2

Drawn by DateLB 12.02.20

Checked by Date.

M1.2

Written dimensions on these drawings shallhave precedence over scale dimensions.

Contractor shall verify and be responsible for alldimensions and conditions on the job and this

office must be notified of any variations from thedimensions and conditions.

© COPYRIGHT

10739 Tucker St #260Beltsville MD 20705

301.579.4563

Mec

hani

cal P

lans

MECHANICAL NOTES:1. THE DRAWINGS CONVEY THE GENERAL INTENT OF THE DESIGN.CONTRACTOR SHALL EXAMINE THE SIDE AND ALL DRAWINGS BEFOREPROCEEDING WITH THE LAYOUT AND INSTALLATION OF WORK. THECONTRACTOR IS RESPONSIBLE FOR ASCERTAINING THE EXISTINGCONDITIONS, LOCATIONS, RUNS, SIZES, MATERIALS, SLOPES, ETC.

2. ARRANGE THE WORK ESSENTIALLY AS SHOWN, EXACT LAYOUT TO BEMADE ON THE JOB TO SUIT ACTUAL CONDITIONS. CONFER AND COOPERATEWITH OTHER TRADES ON THE JOS SO ALL WORK WILL BE INSTALLED INPROPER RELATIONSHIP. PRECISE LOCATION OF PARTS TO COORINDATEWITH OTHER WORK IS THE RESPONSIBILITY OF THE CONTTRACTOR

3. TOILET EXHAUST FANS WITH A RATED FLOOR/CEILING ASSMEMBLY SHALLBE WALL MOUNTED OR UNDER CEILING MOUNTED AND SHALL HAVE A FIREDAMPER INSTALLED IN THE DISCHARGE DUCT AT EACH PENETRATION OF ARATED FLOOR/CEILING/WALL ASSEMBLY

4. ENSURE THAT TOILET ROOM DOORS ARE UNDERCUT ONE INCH TO ALLOWFOR MAKEUP AIR FOR THE EXHAUST.

5. FIRE DAMPERS SHALL BE INSTALLED AT ALL DUCT PENETRATIONS OF FIRERATED WALLS. FIRE DAMPERS ARE NOT REQUIRED AT PENTRATIONS OFFLOORS FOR DUCTING ENCLOSED IN FIRE RATED CHASES

6. ALL FIRE DAMPERS SHALL BE ACCESSIBLE. PROVIDE ACCESS DOORS INDUCTS AND ADJACENT FINISHES AS NEEDED.

7. THE CONDENSING UNIT SHALL BE INSTALLED ON PRECAST CONCRETE ORCOMPOSITION PAD SUPPLIED BY THE MECHANICAL CONSTRACTOR.

8. CONSULT WITH HVAC UNIT MANUFACTURER FOR INSTALLATIONREQUIREMENTS PRIOR TO INSTALL.

9. PROGRAMMABLE THERMOSTAT. WHERE THE PRIMARY HEATING SYSTEMIS A FORCED-AIR FURNACE, AT LEAST ONE THERMOSTAT PER DWELLINGUNIT SHALL BE CAPABLE OF CONTROLLING THE HEATING AND COOLINGSYSTEM ON A DAILY SCHEDULE TO MAINTAIN DIFFERENT TEMPERATURE SETPOINTS AT DIFFERENT TIMES OF THE DAY. THIS THERMOSTAT SHALLINCLUDE THE CAPABILITY TO SET BACK OR TEMPORARILY OPERATE THESYSTEM TO MAINTAIN ZONE TEMPERATURES DOWN TO 55°F (13°C) OR UP TO85°F (29°C). THE THERMOSTAT SHALL INITIALLY BE PROGRAMMED WITH AHEATING TEMPERATURE SET POINT NO HIGHER THAN 70°F (21°C) AND ACOOLING TEMPERATURE SET POINT NO LOWER THAN 78°F (26°C).

10. THIS PROJECT IS REQUIRED TO SUBMIT AT FINAL INSPECTION A DUCTLEAKAGE TEST SHOWING A PASSING RATING OF <= 8 CFM PER 100 SQUAREFEET CONDITIONED FLOOR AREA AT A PRESSURE OF 25 PASCAL. A WRITTENREPORT OF THE RESULTS OF THE TEST SHALL BE SIGNED BY THE PARTYCONDUCTING THE TEST AND PROVIDED TO THE CODE OFFICIAL UPONREQUEST.

11. SEALING. DUCT SEALING - DUCTS, AIR HANDLERS, AND FILTER BOXES SEALEDPER IRC/IMC AND TESTED - ROUGH-IN OR POST-CONSTRUCTION TESTING MUSTDEMONSTRATE ≤ 4 CFM/100 SF, OR 4% CFA25. SEALED AIR HANDLER -MANUFACTURER’S DESIGNATION OF (MAX) 2% OF DESIGN AIRFLOW RATE

12. AUTOMATIC DAMPERS ARE INSTALLED IN ALL AIR INTAKES ANDEXHAUSTS VENTS PER IMC AND IRC CODE

Page 21: THE HART RESIDENCE

GSPublisherEngine 0.0.100.100

The

Har

t Res

iden

ce64

09 4

th A

venu

eTa

kom

a Pa

rk M

aryl

and

2091

2

Drawn by DateLB 12.02.20

Checked by Date.

E1.0

Written dimensions on these drawings shallhave precedence over scale dimensions.

Contractor shall verify and be responsible for alldimensions and conditions on the job and this

office must be notified of any variations from thedimensions and conditions.

© COPYRIGHT

10739 Tucker St #260Beltsville MD 20705

301.579.4563

PROVIDE ALL NECESSARY COMPONENTS REQUIRED FOR MAKING FINALCONNECTIONS OF ALL EQUIPMENT INSTALLED OR MODIFIED AS PART OF THISCONTRACT.

DRAWINGS ARE DIAGRAMMATIC. ACTUAL LOCATION OF EQUIPMENT TO BEDETERMINED IN THE FIELD. NEW EQUIPMENT SHALL FIT INTO EXISTINGAVAILABLE SPACE. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDEEQUIPMENT WHICH MEETS THE SPACE REQUIREMENT. RELOCATION OFEQUIPMENT TO FIT INTO EXISTING AVAILABLE SPACE SHALL BE ACCOMPLISHEDAT NO ADDITIONAL COST TO THE OWNER.

INSTALLATION OF ALL WIRING AND CONDUITS SHALL CONFORM WITH LATESTEDITION OF THE NATIONAL ELECTRICAL CODE INCLUDING NFPA 96 AND LOCALCODES.

CONDUIT RUNS ARE SHOWN DIAGRAMMATICALLY ONLY, AND SHALL BEINSTALLED IN A MANNER TO PREVENT CONFLICTS WITH EQUIPMENT ANDSTRUCTURAL CONDITIONS. EXPOSED CONDUITS SHALL BE INSTALLED PARALLELTO THE BEAMS AND WALLS.

PROVIDE ALL REQUIRED PULL BOXES AND JUNCTION BOXES FOR INSTALLATIONOF THE WIRING IN ACCORDANCE WITH THE CONTRACT SPECIFICATIONS THOUGHTHE BOXES MAY NOT BE INDICATED ON THE DRAWINGS.

THE WIRING DIAGRAMS, QUANTITY AND SIZE OF WIRES AND CONDUITS AREBASED UPON SELECTED STANDARD COMPONENTS OF ELECTRICAL EQUIPMENT.MODIFICATIONS REQUIRED BY THE LOCAL AUTHORITY HAVING JURISDICTIONSHALL BE COORDINATED PRIOR TO COMMENCEMENT OF WORK.

CUT AND PATCH SLABS, CEILING, ROOF, FLOOR, WALL, ETC. AND OTHERSURFACES AS NECESSARY TO ACCOMPLISH CONSTRUCTION WORK UNDER THISCONTRACT.

ALL JUNCTION AND PULL BOXES SHALL BE LABELED WITH THEIR VOLTAGE ANDUSAGE.

OPENINGS AND PASSAGE OF CONDUITS OR WIREWAYS THROUGH FLOOR SLABSAND FIRE RATED WALLS OR PARTITIONS SHALL BE PROVIDED WITH UL LISTEDFIRE RATED SLEEVING SYSTEMS AS MANUFACTURED BY PROSET SYSTEMS INC.,OR APPROVED EQUAL.

ELECTRICAL REQUIREMENTS FOR MECHANICAL EQUIPMENT ARE BASED ONEQUIPMENT SPECIFIED. COORDINATE EXACT REQUIREMENTS WITH MECHANICALSHOP DRAWINGS PRIOR TO ORDERING AND INSTALLING EQUIPMENT.

WHERE ELECTRICAL INSTALLATIONS DEPEND UPON WORK OF OTHER TRADES,THE ELECTRICAL CONTRACTOR SHALL ENSURE THAT NECESSARYINSTRUCTIONS, TEMPLATES, MATERIALS, ETC. ARE PROVIDED AND SUPERVISETHE WORK OF THE OTHER TRADES FOR QUALITY AND CODE COMPLIANCE.

MINIMUM WIRE SIZE SHALL BE #12 UON. MINIMUM CONDUIT SIZE SHALL BE 3/4"UON.

PROVIDE U.L APPROVED FIRE-STOPPING SYSTEM TO ALL RECESSED ELECTRICALBOXES, PANEL, ETC. IN FIRE RATED WALLS AND CEILINGS.

PROVIDE U.L APPROVED FIRE-STOPPING SYSTEM TO ALL CONDUITS, CABLES,WIRING, SLEEVES, ETC. PENETRATION THROUGH FIRE RATED WALLS, CEILINGSAND FLOORS.

APPROXIMATE LOCATIONS ARE SHOWN FOR ALL CONDUITS AND CONDUITPENETRATIONS. CONTRACTOR SHALLVERIFY LOCATION FOR ALL CONDUITS AND CONDUIT PENETRATIONS. ADJUSTLOCATIONS AS REQUIRED.

1. APPLICABLE CODES AND STANDARDS: PERFORM ALL WORK INACCORDANCE TO THE FOLLOWING CODES AND STANDARDS:A. INTERNATIONAL BUILDING CODE 2017.B. NATIONAL ELECTRICAL CODE 2017.C. INTERNATIONAL ENERGY CODE 2017.D. NATIONAL FIRE PROTECTION AGENCY (NFPA 72).

2. ELECTRICAL CONTRACTOR SHALL VERIFY EXACT LOCATIONS ANDMOUNTING HEIGHTS OF ALL ELECTRICAL EQUIPMENT WITH THEARCHITECTURAL DRAWINGS.

3. ALL WORK SHALL BE ACCOMPLISHED WITHIN THE INTENT OF THE BASEBUILDING DRAWINGS AND GENERAL SPECIFICATIONS.

4. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION BETWEENALL TRADES PRIOR TO INSTALLATION. REPORT ANY DISCREPANCIESBETWEEN THE EXISTING EQUIPMENT AS INSTALLED AND INFORMATIONAS SHOWN ON THE DRAWINGS, AS WELL AS NEW EQUIPMENT ASSPECIFIED W/ EQUIPMENT AS TO BE INSTALLED.

5. CONTRACTOR SHALL VISIT THE SITE PRIOR TO BID AND CONSTRUCTIONTO VERIFY ALL EXISTING CONDITIONS, TELECOM AND UTILITY SERVICE.NO ADDITIONAL COST WILL BE ALLOWED AFTER THE BID.

6. EXISTING BASE BUILDING ELECTRICAL SYSTEMS ARE TO REMAIN EXCEPTWHERE MODIFICATIONS ARE REQUIRED AND AS SHOWN ON PLANS.MAINTAIN CONTINUITY OF EXISTING CIRCUITS.

7. ALL ELECTRICAL EQUIPMENT INCLUDING BUT NOT LIMITED TO CONDUIT,WIRE, BOXES, FITTINGS, SHALL BE NEW U.O.N. AND SHALL MEET NEMASTANDARD AND BEAR THE U.L. LABEL.

8. THE CONTRACTOR SHALL RESTORE ALL AREAS AND SYSTEMSDISTURBED BY HIS WORK TO THE SATISFACTION OF THE ARCHITECT ANDENGINEER.

9. ALL WORK AND MATERIAL SHALL BE GUARANTEED FREE FROM DEFECTSAND WORKMANSHIP FOR A PERIOD OF ONE YEAR, INCLUDING ALLREUSED EXISTING ELECTRICAL EQUIPMENT.

10. CIRCUIT CONTINUITY SHALL BE MAINTAINED FOR EXISTING ELECTRICALEQUIPMENT TO REMAIN AND/OR BE RELOCATED.

11. CONDUIT RUNS ARE SHOWN SCHEMATICALLY, BUILDING CONDITIONSWILL DETERMINE THE ACTUAL CONDUITS RUN. CONDUITS SHALL BECONCEALED, UNLESS OTHERWISE NOTED.

12. COLOR CODE AND IDENTIFY ALL WIRES IN PULL BOXES AND PANELS.

13. ITEMS TO BE REMOVED: UNLESS OTHERWISE NOTED, CONTRACTORSHALL PERFORM THE FOLLOWING:

A. IF THE CONDUIT SERVING THE ITEM IS CONCEALED, THECONTRACTOR SHALL REMOVE ALL CONDUCTORS, CUT CONDUITBACK TO BELOW GRADE, FLOOR, OR ABOVE CEILING, AND PATCH TOMATCH EXISTING.

B. IF THE CONDUIT SERVING THE ITEM IS EXPOSED, THE CONTRACTORSHALL REMOVE CONDUIT AND CONDUCTORS BACK TO SOURCE.

14. ITEMS TO BE RELOCATED: UNLESS OTHERWISE NOTED, CONTRACTORSHALL PERFORMED THE FOLLOWING:

A. IF THE CONDUIT SERVING THE ITEM OR FEEDING OTHER ITEMS ISCONCEALED, THE CONTRACTOR SHALL REMOVE ALL CONDUCTORS,CUT CONDUIT BACK TO BELOW GRADE, FLOOR, OR CEILING, ANDRE-FEED THESE ITEMS WITH NEW CONDUIT AND WIRE AS SHOWN ONTHE DRAWING.

B. IF THE CONDUIT SERVING THE ITEMS IS EXPOSED, THE CONTRACTORSHALL REROUTE CONDUIT AND CONDUCTORS WHERE POSSIBLE ORRUN NEW CONDUIT AND CONDUCTORS AS MAY BE REQUIRED.

C. IF AN ITEM IS TO BE REPLACED, THE CONTRACTOR SHALLRECONNECT ALL EXISTING CONNECTIONS.

15. EXACT LOCATION, MOUNTING HEIGHT, AND TYPE OF TERMINATION FROMJUNCTION BOXES, STUB-UPS, DISCONNECT SWITCHES, ETC. SHALL BEDETERMINED FROM ARCHITECTURAL DRAWINGS, SHOP DRAWINGS,EQUIPMENT CUTS OR DETAILS BEFORE CONDUIT ROUGH-IN.

16. PROVIDE SINGLE COMMON COVER PLATE IN ALL AREAS WHERE DEVICESARE GANGED MORE THAN TWO IN GROUP TOGETHER.

17. THE CONTRACTOR SHALL NOT CORE DRILL CONCRETE SLABS WITHOUTTHE KNOWLEDGE AND WRITTEN CONSENT OF THE STRUCTURALENGINEERS AND THE BUILDING ENGINEERS.

18. CONTRACTOR TO SCAN PROPOSED CORE DRILL LOCATIONS WITH GPRDEVICE TO PREVENT CUTTING THROUGH CONCEALED RE-BARS AND/ORCONDUIT IN SOLID CONCRETE FLOOR SLAB.

20. PROVIDE DISCONNECT SWITCHES/STARTERS IF NOT FURNISHED INTEGRALWITH THE MECHANICAL EQUIPMENT. SIZE DISCONNECT SWITCH/STARTERAS RECOMMENDED BY EQUIPMENT MANUFACTURER.

21. FIELD VERIFY EXISTING FIRE ALARM CONTROL PANEL. IF REQUIREDPROVIDE ACCESSORIES TO ACCOMMODATE NEW DEVICES.

22. CONTRACTOR SHALL VERIFY ALL EQUIPMENT REQUIREMENTS BEFOREINSTALLING CONDUIT OR CONDUCTORS FROM POWER SOURCE TOEQUIPMENT TERMINATION.

23. ALL WIRE SIZES ARE BASED ON COPPER CONDUCTORS.

24. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL WIRES NECESSARYFOR PROPER FUNCTION OF THE SYSTEM.

25. ALL WIRING SHALL BE INSTALLED IN CONDUIT. CONDUCTORS SHALL BETYPE THHN OR THWN. MINIMUM WIRE SIZE SHALL BE #12 AWG. MINIMUMCONDUIT SIZE SHALL BE 3/4". THE USE OF TYPE AC CABLE IS PERMISSIBLE.

26. PANELBOARDS: PANELBOARDS SHALL BE INDICATED ON SCHEDULE, WITHBOLT-ON, BRANCH CIRCUIT BREAKERS AND COPPER BUSS OR MATCH BASEBUILDING DISTRIBUTION EQUIPMENT.

27. WALL PLATES:A. MATERIAL FOR FINISHED SPACES: SMOOTH, HIGH-IMPACT

THERMOPLASTIC.B. MATERIAL FOR UNFINISHED SPACES: SMOOTH, HIGH-IMPACT

THERMOPLASTIC.C. MATERIAL FOR DAMP LOCATIONS: THERMOPLASTIC WITH

SPRING-LOADED LIFT COVER, AND LISTED AND LABELED FOR USE IN"WET LOCATIONS."

D. FINISH AS SELECTED BY ARCHITECT.

28. CONTRACTOR TO PROVIDE FURNISHED AS-BUILT DRAWINGS AND BUILDINGOWNER'S MANUALS FOR ALL ELECTRIC POWER SYSTEM FOR RECORD.

29. INTERRUPTION OF EXISTING ELECTRIC SERVICE: NOTIFY THE BUILDINGENGINEERS OR OWNER AT LEAST 5 DAYS IN ADVANCE OF PROPOSEDCUT-OFF ELECTRICAL SERVICE TO THE BUILDING.

Elec

trica

l Not

es

Page 22: THE HART RESIDENCE

GSPublisherEngine 0.0.100.100

The

Har

t Res

iden

ce64

09 4

th A

venu

eTa

kom

a Pa

rk M

aryl

and

2091

2

Drawn by DateLB 12.02.20

Checked by Date.

E1.1

Seco

nd F

loor

Ele

ctric

al P

lan,

Firs

t Flo

orEl

ectr

ical

Pla

n

Written dimensions on these drawings shallhave precedence over scale dimensions.

Contractor shall verify and be responsible for alldimensions and conditions on the job and this

office must be notified of any variations from thedimensions and conditions.

© COPYRIGHT

10739 Tucker St #260Beltsville MD 20705

301.579.4563

F

+6'-3

"

+6'-3

"

SD

+6'-3

"

gd

dw

LIVINGAREA

DININGAREAKITCHEN

HALL

M.BATH

M.BEDROOM

DW

+6'-3"

SD

220

CO

+6'-3

"

+6'-3"

+6'-3"

+6'-3

"

220

CO

SD

SD

DIMMER SWITCH

EXHAUST FAN

4-WAY SWITCH

DOOR BELL

FAN LIGHT COMBO

RECEPTACLE DUPLEX OUTLET

OUTLET WALL FIXTURE

WALL SCONCE

VANITY FIXTURE

RECESSED CAN LIGHT

PENDANT LIGHT

UNDER CABINETFLOURESCENT LIGHT

FLOURESCENT LIGHT

CEILING FAN W/LIGHT

SMOKE DETECTOR-HARDWIRED, INTERCONNECTED,BATTERY BACKUP

3-WAY SWITCH

TELEPHONE

CABLE TELEVISION RECEPTACLE

THERMOSTAT

SINGLE DOOR OPEN

RECEPTACLE 220V

SWITCH

RECEPTACLE DUPLEXWATERPROOF

GFI RECEPTACLEDUPLEX OUTLET

D

ELECTRICAL SCHEDULE

INSTALL AFCI OUTLETS PER NECCODE

CARBON MONOXIDE ALARM

LED CAN LIGHT

SURFACE LIGHT

MUDROOM/LAUNDRY DEN

EXMECHCLO

BED #1

BED #2

HALL

EXELECTPANEL

+6'-3

"

220

+6'-3

"

2.E1.1

Second Floor Electrical Plan1/4" = 1'-0"

1.E1.1

First Floor Electrical Plan1/4" = 1'-0"

Page 23: THE HART RESIDENCE

GSPublisherEngine 0.0.100.100

The

Har

t Res

iden

ce64

09 4

th A

venu

eTa

kom

a Pa

rk M

aryl

and

2091

2

Drawn by DateLB 12.02.20

Checked by Date.

P1.0

Written dimensions on these drawings shallhave precedence over scale dimensions.

Contractor shall verify and be responsible for alldimensions and conditions on the job and this

office must be notified of any variations from thedimensions and conditions.

© COPYRIGHT

10739 Tucker St #260Beltsville MD 20705

301.579.4563

EX COLDWATERSERVICE,VIF

ex 3/4"

1/2"1/2"

3/4"

1/2"1/2"

2"

SOIL/WASTE

VENT

1ST FLOOR

BSM'T FLOOR

ROOF

EXSTACK

sink

2"

D/W

1 1/2"

2"

1 1/2"

2"

1 1/2"

3"

ex DRAIN

3"

TO EX PUBLIC DRAIN

ex C.O.

3"

2"

3"

3"

2"

2"

ex. ventthru roof

lav

2"

1 1/2"

W.C.

2"

2"

1 1/2"

COLD WATER

HOT WATER

D/W

1ST FLOOR

BSM'T FLOOR

ATTIC FLOOR

boiler

ex. gas

sink

lav

WATER SUPPLY

DRAINAGE AND VENT

PLUMBING NOTES

tub

dryerwasher

2"

shower

1 1/2"

shower

1/2"

lavW.C.

1/2"1/2"

1 1/2"

lav

1 1/2"

W.C.

2"

2"

1. ALL PLUMBING LINES ARE EXISTINGUNLESS NOTED OTHERWISE

2. CONTRACTOR TO VERIFY EX PLUMBINGAND NOTIFY ARCHITECT OF ANYDISCREPENCIES PRIOR TO FOR APPROVAL.

3. MASTER PLUMBER TO COORDINATEEXISTING LINES WITH NEW LINES PERCODE

Plum

bing

Not

es a

nd R

iser

Dia

gram

s

PLUMBING NOTES1. MASTER PLUMBER TO COORDINATEEXISTING LINES WITH NEW LINES PER CODE

COLD WATER

HOT WATER

DRAIN

DRAIN PIPE LINE

HOSE BIB

1/2"1/2"

Page 24: THE HART RESIDENCE

GSPublisherEngine 0.0.100.100

The

Har

t Res

iden

ce64

09 4

th A

venu

eTa

kom

a Pa

rk M

aryl

and

2091

2

Drawn by DateLB 12.02.20

Checked by Date.

P1.1

Seco

nd F

loor

Plu

mbi

ng P

lan,

Firs

t Flo

orPl

umbi

ng P

lan

Written dimensions on these drawings shallhave precedence over scale dimensions.

Contractor shall verify and be responsible for alldimensions and conditions on the job and this

office must be notified of any variations from thedimensions and conditions.

© COPYRIGHT

10739 Tucker St #260Beltsville MD 20705

301.579.4563

PLUMBING NOTES1. ALL PLUMBING LINES ARE EXISTINGUNLESS NOTED OTHERWISE

2. CONTRACTOR TO VERIFY EX PLUMBINGAND NOTIFY ARCHITECT OF ANYDISCREPENCIES PRIOR TO FOR APPROVAL.

3. MASTER PLUMBER TO COORDINATEEXISTING LINES WITH NEW LINES PERCODE

F

2"

3"

2"

3"

2"

2" 2"

TO STACK,VIF

DW

DRAIN PIPE ATCONT FT'G, TYP

WINDOW WELLDRAIN TIED INTODRAIN PIPE, TYP

2"

3"3" 2"

2"3"2"

EX3"

TO EX SEWER

2.P1.1

Second Floor Plumbing Plan1/4" = 1'-0"

1.P1.1

First Floor Plumbing Plan1/4" = 1'-0"

LEGEND

COLD WATER

HOT WATER

DRAIN

DRAIN PIPE LINE

HOSE BIB