the flexible solution - · pdf filemm kg inch sap-fmrv93eh 2.80 4.00 30/40/43 300/360/400...
TRANSCRIPT
The flexible solution
The new SANYO Flexi Multi range of heat pump multi split
systems are the ideal, flexible solution for providing quiet and
efficient air conditioning to 2, 3 or 4 areas from a single outdoor
unit.
• 3 system capacities 5.6,6.8 and 9.0kW
• 6 indoor model styles
• 2, 3 or 4 way multi split
• DC inverter technology for precise
temperature control and low start
current
• Provides heating or cooling as required
but not simultaneously
IR410AI
The Flexi Multi systems utilise the non-ozone depleting
R410A refrigerant, this means increased system
performance, increased energy efficiency and improved
heat transfer which results in smaller pipe sizes and
more compact indoor units.
Simple, one touch control• Full function Remote Controller
• Built-in temperature sensor
• Temperature setting
• Operational mode selection
• Fan speed control
• 24 hour on/off timer
• I hour timer
/Energy ~ All Flexi Multi DC inverter models are ratedMant!fm;tvrer I SA/IYO i
~~~"a as EEL Category A, which confirms that they~ are amongst the most energy efficient_II>~ systems available. Power consumption during
operation is substantially less than that of lower rated units
and consequently both the day to day running costs and full
life cycle costs are significantly reduced.
2 "-- -'"
SANYO Flexi Multi systems qualify for
inclusion on the Energy Technology List and
therefore for 100% first year enhanced
capital allowances, where the total cost of the
system and installation can be offset against taxable profits
in the year of purchase. For further information, visit
www.eca.gov.uk or email [email protected].
• Designed for flush mounting against a wall
• Choice of indoor unit styles
• Auto swing louvres for optimum air distribution
• 3 fan speeds
• Quiet operation
• High power mode for rapid cooling or heating
Indoor SAP-KMRV93GjHSAP-KMRV 123GjH SAP-KMRV 183GjH SAP-KMRV243GjHNominal Cooling
kW2.803.605.007.00
Nominal Heating
kW4.004.807.108.00Noise Levels - LMH
dB(A)II33738/41 33/39/4638/44/4938/43/47-- -=-'"Airflow - LMH m3fh370/510/620400/450/580530/620/680920/1000/1 100
[ Dimensions -. HYv'D_JLn mm ••lr J752<8OSXTf§.J1285x805x212~x805x219- II 33_02<I 140x228- Weight kg8.59.510.018.0
Pipe Sizes
-- ~--- 11inc.h 1/4,3/8
-1/4,3/8
-1/4,1/2
• Designed to fit into standard 600mm x 600mm ceiling grid
• Fresh air knock out
• Multi directional airflow
• Integrated drain pump give 250mm lift
• Auto swing louvres for optimum air distribution
• Quiet operation
Indoor
Nominal Cooling
Nominal HeatingNoise Levels - LMH
Airflow - LMH
Dimensions - HWD
Weight
Pipe Sizes
II
I
kWkW
dB(A)m3fh
mmkg
inch
SAP-XMRV93EH
2.80
4.00
11 ~740/44500/600/700
273x575x57516.5
1/4:3/8
SAP-XMRV 123EH
3.60
4.80
:J7140/44
500/600/700
273x575x57516.5
1/4,3/8
SAP-XMRVI83EH
5.00
7.1037/40/45
530/630/750
273x575x575
18.2
1/4;3/8 3
• Ideal for perimeter air conditioning
• Compact design, just 200mm deep, requires small
installation space
• Quiet operation from 34dB(A)
• 3 fan speeds
• Infra red remote control
Indoor
Nominal CoolingNominal HeatingNoise Levels - LMHAirflow - LMHDimensions - HWD
WeightPipe Sizes
kWkW
dB(A)m3fhmmkg
inch
SAP-FMRV93EH2.804.00
30/40/43300/360/400
700x560x20018.0
1/4,3/8
• Unobtrusive installation designed for bulkhead applications
• Condensate removal from either end
• Infra red remote control
• 3 fan speeds
Indoor SAP-DMRV93GjHSAP-DMRV 123GjH SAP-DMRV 183GjH SAP-DMRV243GjHNominal Cooling
kW2.803.605.007.00
Nominal Heating
kW4.004.807.108.00
Noise ~evels - LMH11 _<!~(6fn37/39/4-1
-37/39/41 37/39/41n39/41/52
Airflow - LMH
m3fh700/760/850700/760/850700/760/850680/760/1180
Dimensions - HWDIlmm 260x958x479~260x958x479
260x958x479 _ 11260x95Jx479Weight
kg19.019.019.019.0
~ipe Sizes
-lrinchII~1/4'3~ 1/4,3~U1/4,3/8U1/4,1/24
• Flexible design allows floor or ceiling mounting without modification
• Large and wide air distribution
• Auto air sweep for optimum distribution
• 3 fan speeds
• Quiet operation
• Infra red remote control
Indoor
Nominal Cooling
Nominal HeatingNoise Levels - LMHAirflow - LMH
Dimensions - HWD
Weight
Pipe Sizes
kWkW
dB(A)m3fhmm
SAP-FTMRV 123EH
3.60
4.80
38/43/47
500/590/700
600x900xl9023.5
1/4:%
SAP-FTMRV 183EH
5.00
7.10
41/45/49
590/700/800
600x900xl90
23.5
1/4.1/2
SAP-FTM RV223 EH
6.00
7.50
42/46/50
670/770/840
600x900xl90- ~ -23.5
1/4.1/2
• Ideal for flexible. concealed air conditioning
• Infra red remote control
• Built-in drain pump gives 250mm lift
• 3 fan speeds
Receiver unit
Indoor SAP-UMRV93EHSAP-UMRVI23EHSAP-UMRVI83EHSAP-UMRV223EHNominal Cooling
kW2.803.605.006.00Nominal Heating
kW4.004.807.107.50Noise Levels - LM'H n ndB(~) _ 1r36/38/4 fIL36i38/41
-42/47i51n44/48/52
Airflow - LMHm3fh440/510/600440/5 I 0/600400/600/875600/700/ I000
Dimensions - Hwb n" _mm266x852x5iJU ·l~~§~2x57t II266x 1058x5 71__ Jl266x I 058x57 1- --
Weight kg16.516.518.223.5Pipe Sizes
1r - inchir1/4.3/8lr1/4.3;:-II- 1/4,3/8-- IL-1/4,1/2....I5
The Flexi Multi outdoor units utilise the latest SANYO twin
rotary compressor in which perfectly balanced dual rotors
revolve smoothly and efficiently to provide powerful, quiet and
vibration free performance.
Advanced DC compressor design
SAP-CMRV 1923GJH
Heating Mode
Q'C " "
lime until desined temperatune is neached
",
¢lime
Conventional air conditioner
Cooling Mode
\, Inverter air conditionerX Conventional air conditioner""'~
Desinedtemperatune
Room Temp. li
Room Temp. li
Desinedtemperature
Rapid and accurate temperature control
The Flexi Multi Systems use Advanced Digital Hybrid (ADH)
technology for better, smarter and more cost-efficient year
round climate control. Immediately following start up, the DC
compressor operates at maximum power to provide almost
Instant heating or cooling. As the desired air temperature is
reached, a special Pulse Width Module automatically adjusts
the compressor's frequency to exactly meet the cooling or
heating requirements of the room. The result is exceptionally
precise temperature control, less noise and significant energy
savings.
Q'C " "
lime until desired temperatune is reached¢lime
Outdoor Units SAP-CMRV 1923GjHSAP-CMRV2433GjHSAP-CMRV3143GjH
Nominal Cooling
kW5.60 6.809.00
Nominal Heating
kW7.30 8.6010.00
COP - C1H1lJl
~3.20/ 3.46
-U-
3.33 / 3.81 n4~64 / 4.61-Noise Levels - C H dB(A)4849 48495354
Dimensions - HWD
JImmII730X940x34'6 nOx91,Ox340n880x940xJ40-Weightkg69.0 70.090.0
Power SUI?Ply
II1 pha~E;,pha~eIII phase
Interconnecting Wiring
1.5mm3 core + earth3 core + earth3 core + earth
Run Current - H II
A
Jl
9.9
J[ -
10.6JI
9.7
Fuse Size
A20 2030- Max. Pipe Run Per Indoor Unitm25 2530
Max.Total Pipe Run
m35 5070
Max. Height Difference
m10 1010
Connectable Units
II2Ii3II46