@ AT AB ANCHOR BOLT ABV ABOVE ATR ALL-THREAD ROD ARCH ARCHITECTURAL BC BOTTOM CHORD BLDG BUILDING BLKG BLOCKING BM BEAM BN BOUNDARY NAILING BOT BOTTOM BO BOTTOM OF BOS BOTTOM OF STEEL CENTER LINE CIP CAST-IN-PLACE CLG CEILING CLR CLEAR CJ CONTROL JOINT CMU CONCRETE MASONRY UNIT COL COLUMN CONC CONCRETE CONT CONTINUOUS CP CONTROL POINT (D) DEMOLISH DBL DOUBLE DEFL DEFLECTION DET DETAIL DIA DIAMETER DO DITTO DWG DRAWING (E) EXISTING E EAST EA EACH ES EACH SIDE EN EDGE NAIL EL ELEVATION, END LENGTH EW EACH WAY EJ EXPANSION JOINT EQ EQUAL EXP ANC EXPANSION ANCHOR EXT EXTERIOR FE FIRE EXINGUISHER FEC FIE EXTINGUISHER CABINET FS FAR SIDE FDN FOUNDATION FIN FINISH FG FINISHED GRADE FLR FLOOR FO FACE OF FOC FACE OF CONCRETE FOF FACE OF FRAMING FOM FACE OF MASONRY FOS FACE OF STUD FTG FOOTING FOCMU FACE OF CMU GA GAUGE GB GRADE BEAM GL GLUE LAMINATED (BEAM) GWG GYPSUM BOARD GYP GYPSUM HCA HEADED CONC ANCHOR (STUD) HDR HEADER H, HORIZ HORIZONTAL HDG HOT DIPPED GALVANIZED HS HIGH STRENGTH HSB HIGH STRENGTH BOLTS HSS HOLLOW STRUCTURAL SECTION INT INTERIOR LLH LONG LEG HORIZONTAL LSL LAMINATED STAND LUMBER LLV LONG LEG VERTICAL LONG LONGITUDINAL LSH LONG SLOTTED HOLE LVL LAMINATED VENEER LUMBER MFR MANUFACTURER MB MACHINE BOLTS MAX MAXIMUM MTL METAL MIN MINIMUM MISC MISCELLANEOUS (N) NEW N / NO. NORTH NS NEAR SIDE NTS NOT TO SCALE OC ON CENTER OPG OPENING OH OPPOSITE HAND OP OPPOSITE OSB ORIENTED STRAND BOARD OSSC OREGON STRUCTURAL SPECIALTY CODE O/ OVER PSL PARALLEL STRAND LUMBER PLATE (STEEL) PLY PLYWOOD PMJ PRE-MOLDED JOINT FILLER PT PRESSURE TREATED REINF REINFORCEMENT REQ'D REQUIRED RJ ROUGHENED CONSTRUCTION JOINT RO ROUGH OPENING RS ROUGH SAWN S / SO. SOUTH SAD SEE ARCHITECTURAL DRAWING SC SLIP CRITICAL SCHED SCHEDULE SDWS SELF-DRILLING WOOD SCREW SGD SEE GEOTECH DESIGN / REPORT SHTH'G SHEATHING SIM SIMILAR SOG SLAB ON GRADE SPEC SPECIFICATION SQ SQUARE SSH SHORT SLOTTED HOLE SS STAINLESS STEEL SYMM SYMMETRICAL TBD TO BE DETERMINED TC TOP CHORD TN TOE NAIL T&B TOP AND BOTTOM TO TOP OF TOC TOP OF CONCRETE TOF TOP OF FRAMING TOFS TOP OF FLOOR SHEATHING TOM TOP OF MASONRY TOS TOP OF STEEL TRANS TRANSVERSE TYP TYPICAL UNO UNLESS NOTED OTHERWISE UT ULTRASONIC TESTING VERT VERTICAL W WEST WA WALL ASSEMBLY W/ WITH W/O WITHOUT WP WORK POINT, WATERPROOFING 1 SHEET INDEX 5 ABBREVIATIONS 9 SUBMITTALS 13 SPECIAL INSPECTION 17 SPECIAL INSPECTION 21 GENERAL NOTES GENERAL 1. ALL CONSTRUCTION TESTING AND INSPECTIONS SHALL CONFORM TO THE 2012 IBC AND 2014 OSSC. 2. CONSTRUCTION LIABILITY: CONSTRUCTION CONTRACTOR AND HIS/HER SUBCONTRACTORS AGREE THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, CONSTRUCTION CONTRACTOR AND HIS/HER SUBCONTRACTORS WILL BE REQUIRED TO ASSUMED SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THE PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND NOT LIMITED TO NORMAL WORKING HOURS, AND CONSTRUCTION CONTRACTOR AND HIS/HER SUBCONTRACTORS FURTHER AGREE TO DEFEND, INDEMNIFY, AND HOLD DESIGN PROFESSIONAL HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THE PROJECT EXCEPT LIABILITY FROM THE SOLE NEGLIGENCE OF THE DESIGN PROFESSIONAL. 3. DURING THE CONSTRUCTION PERIOD, THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY OF THE BUILDING. THE CONTRACTOR SHALL PROVIDE ADEQUATE SHORING, BRACING, AND GUYS IN ACCORDANCE WITH ALL NATIONAL, STATE, AND LOCAL SAFETY ORDINANCES. 4. THE STABILITY AND INTEGRITY OF THE EXISTING STRUCTURES DURING CONSTRUCTION SHALL BE MAINTAINED AT LEVELS GENERALLY ACCEPTABLE WITHIN THE CONSTRUCTION INDUSTRY BY THE USE OF BRACING, SHORING AND UNDERPINNING UNTIL THE PROPOSED STRUCTURE MODIFICATIONS ARE COMPLETED, IN NO CASE SHALL THE EXISTING STRUCTURES BE ALLOWED TO BECOME UNSAFE DURING CONSTRUCTION. 5. THE BRACING AND SHORING SYSTEMS REQUIRED TO PROVIDE TEMPORARY SUPPORT OF THE STRUCTURE DURING CONSTRUCTION SHALL BE DESIGNED TO SUPPORT THE DEAD, LIVE, SOIL, EARTHQUAKE, AND WIND LOADS THAT MAY BE IMPOSED ON THE STRUCTURE DURING CONSTRUCTION, IN ACCORDANCE WITH INDUSTRY STANDARDS AND GENERALLY ACCEPTED ENGINEERING PRINCIPLES. 6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING UTILITIES WHETHER SHOWN HEREIN OR NOT, AND TO PROTECT THEM FROM DAMAGE. THE CONTRACTOR SHALL BEAR ALL EXPENSE OF REPAIR OR REPLACEMENT IN CONJUNCTION WITH THE PERFORMANCE OF THIS WORK. 7. DO NOT SCALE THE DRAWINGS. 8. WHERE A CONFLICT OCCURS BETWEEN SPECIFICATIONS, NOTES ON THE DRAWINGS, GENERAL NOTES, AND SPECIFIC DETAILS, THE MORE RESTRICTIVE SHALL GOVERN. 9. OMISSIONS OR DISCREPANCIES BETWEEN THE VARIOUS ELEMENTS OF THE CONTRACT DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER BEFORE PROCEEDING WITH THE WORK. 10. VERIFY ALL EXISTING FEATURES AND CONDITIONS (DIMENSIONS, ELEVATIONS, ETC.) UPON WHICH THESE DRAWINGS RELY. 11. CONTRACTOR TO VERIFY ALL DIMENSIONS AND ELEVATIONS SHOWN ON STRUCTURAL, CIVIL, ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE DRAWINGS. NOTIFY ENGINEER OF ANY CONFLICTING INFORMATION PRIOR TO BEGINNING CONSTRUCTION. 12. ALL DETAILS ARE TYPICAL. FOR CONDITIONS NOT SPECIFICALLY SHOWN, PROVIDE DETAILS SIMILAR TO THOSE SHOWN, SUBJECT TO ENGINEER'S REVIEW. FOR CONDITIONS WITH NO SIMILAR DETAIL SHOWN. CONTRACTOR TO SUBMIT DETAIL FOR ENGINEERS APPROVAL PRIOR TO USE. 13. COORDINATE STRUCTURAL WORK WITH THE CIVIL, ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, & FIRE WORK DOCUMENTS. 14. OPENINGS IN FLOORS, BEAMS, OR JOIST LARGER THAN THOSE SHOWN ON TYPICAL DETAILS OF STRUCTURAL DRAWINGS SHALL BE REVIEWED BY THE ENGINEER OF RECORD BEFORE PROCEEDING WITH THE WORK. 15. ALL CONSTRUCTION AND POUR JOINTS TO BE APPROVED BY THE ENGINEER. 16. VIBRATION EFFECTS OF MECHANICAL EQUIPMENT ARE NOT CONSIDERED TO BE DETRIMENTAL TO THE STRUCTURAL DESIGN AND HAVE NOT BEEN CONSIDERED BY THE STRUCTURAL ENGINEER. 17. ITEMS IDENTIFIED BY TRADE NAME ARE INDICATIVE OF A LEVEL OF PERFORMANCE OR A GRADE OF MATERIAL. IN ALL SUCH CASES THE PHRASE "OR APPROVED EQUAL" SHALL APPLY. SUBSTITUTES SHALL BE SUBMITTED FOR APPROVAL PRIOR TO USE. 18. NO CONSTRUCTION OR ORDERING MATERIALS SHALL TAKE PLACE UNTIL THE CONTRACTOR HAS RECEIVED REVIEWED SUBMITTALS BY THE ENGINEER. 19. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS AS REQUIRED BY THESE DOCUMENTS AFTER THE CONTRACTOR HIMSELF HAS REVIEWED THE SUBMITTALS. ENGINEERING REVIEW OF ANY SUBMITTALS IS ONLY FOR COMPLIANCE WITH GENERAL STRUCTURAL REQUIREMENT AND IS SPECIFICALLY NOT FOR DIMENSIONAL OR QUANTITATIVE INFORMATION. 20. THE SUBMITTALS SHALL SHOW LAYOUT, SIZE OF MEMBERS, CONNECTION DETAILS AND CONSTRUCTION SEQUENCE FOR ALL BRACING AND SHORING SYSTEMS. THE SUBMITTALS SHALL BE ACCOMPANIED BY STRUCTURAL CALCULATIONS SIGNED BY A REGISTERED STRUCTURAL ENGINEER. THE ENGINEER SHALL ALSO PROVIDE A LETTER STATING THAT HE/SHE HAS REVIEWED THE SUBMITTALS FOR COMPLETENESS AND SHALL PERFORM FIELD VISITS AS REQUIRED IN ORDER TO CHECK GENERAL CONFORMANCE OF THE CONSTRUCTION TO THE CALCULATIONS. STRUCTURAL OBSERVATION 1. STRUCTURAL OBSERVATION WILL BE IN ACCORDANCE WITH THE 2014 OSSC TOGETHER WITH LOCAL AND STATE AMENDMENTS, REFER TO PROJECT SPECIFIC NOTES ON THIS SHEET. 2. ONSITE STRUCTURAL OBSERVATION WILL BE PERFORMED FOR EACH IDENTIFIED SEISMIC FORCE-OR WIND FORCE-RESISTING SYSTEM, INCLUDING FOUNDATIONS AND CONNECTIONS. REFER TO THE INDIVIDUAL FACILITY PLANS FOR THE BASIC SEISMIC- AND WIND-RESISTING SYSTEMS FOR THE STRUCTURES INCLUDED IN THE WORK. 3. STRUCTURAL OBSERVATION WILL BE PERFORMED BY A REGISTERED PROFESSIONAL ENGINEER FOR GENERAL CONFORMANCE TO THE APPROVED CONSTRUCTION DOCUMENTS. STRUCTURAL OBSERVATION DOES NOT PRECLUDE OR WAIVE THE RESPONSIBILITY FOR ANY REQUIRED INSPECTIONS OR INSPECTION BY THE BUILDING OFFICIAL. 4. STRUCTURAL OBSERVATION REPORTS, NOTING ANY DEFICIENCIES IN OBSERVED CONSTRUCTION, WILL BE DELIVERED TO THE CONTRACTOR, BUILDING OFFICIAL, AND OWNER FOLLOWING EACH OBSERVATION. THE CONTRACTOR WILL BE NOTIFIED ON-SITE OR BY PHONE OR EMAIL WITHIN 24 HOURS UPON FINDING ANY DEFICIENCIES. 5. AT THE CONCLUSION OF CONSTRUCTION, A WRITTEN STATEMENT IS REQUIRED TO VERIFY THAT THE STRUCTURAL OBSERVATION SITE VISITS WERE MADE AND WHETHER THERE REMAIN ANY STRUCTURAL DEFICIENCIES THAT HAVE NOT BEEN RESOLVED. 6. STRUCTURAL OBSERVATION WILL INCLUDE VISUAL OBSERVATION OF THE STRUCTURAL SYSTEM AT THE CONSTRUCTION STAGES INDICATED IN THE STRUCTURAL OBSERVATION TABLE AND AT COMPLETION OF THE STRUCTURAL SYSTEM FOR EACH STRUCTURE CONTAINED IN THE WORK. THE CONTRACTOR SHALL SCHEDULE AND FACILITATE STRUCTURAL OBSERVATION FOR THE LINE ITEMS LISTED BELOW. SUBMITTALS 1. BACKFILL MATERIAL GRADING. 2. CONCRETE MIX. 3. REBAR SHOP DRAWINGS. 4. EMBEDDED BOLTS. 5. STRUCTURAL STEEL SHOP DRAWINGS. 6. OPEN-WEB SHOP DRAWINGS. 7. PAN DECK SHOP DRAWINGS. 8. COLD-FORMED FRAMING & WINDOW WALL SYSTEM. 9. CMU REINFORCING. 10. CMU WALL ELEVATIONS. 11. CMU MORTAR MIX. 12. CMU GROUT MIX. 13. ROOF BALLAST 14. ROOF TOP UNITS 15. SUSPENDED CEILING SYSTEM SPECIAL INSPECTIONS 1. SPECIAL INSPECTION WILL BE IN ACCORDANCE WITH THE 2014 IBC SECTION 1704 TOGETHER WITH LOCAL AND STATE AMENDMENTS. IF APPLICABLE, REFER TO THE TABLES CONTAINED ON THESE GENERAL SHEETS FOR PROJECT SPECIFIC INSPECTION TYPES AND FREQUENCIES. 2. SPECIAL INSPECTION WILL BE PROVIDED BY A CERTIFIED AND QUALIFIED INSPECTOR AND ASSOCIATED TESTING WILL BE PERFORMED BY AN APPROVED ACCREDITED AGENCY. THE OWNER WILL SECURE AND PAY FOR THE SERVICES OF THE AGENCY TO PERFORM ALL SPECIAL INSPECTION AND ASSOCIATED TESTS. INSPECTORS FOR EACH SYSTEM AND MATERIAL WILL BE INTERNATIONAL CODE COUNCIL (ICC) CERTIFIED OR OTHERWISE APPROVED BY THE BUILDING OFFICIAL. 3. THE SPECIAL INSPECTOR WILL OBSERVE THE INDICATED WORK FOR COMPLIANCE WITH THE APPROVED CONTRACT DOCUMENTS AND SUBMIT RECORDS OF INSPECTION. ALL DISCREPANCIES WILL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE CONTRACTOR FOR CORRECTION. 4. SPECIAL INSPECTION AND ASSOCIATED TESTING REPORTS WILL BE SUBMITTED TO THE DESIGN TEAM, CONTRACTOR, BUILDING OFFICIAL, AND OWNER WITHIN ONE WEEK OF INSPECTION OR WITHIN ONE WEEK OF TEST COMPLETION. INSPECTIONS FOR WHICH REPORTING WILL BE REQUIRED ARE NOTED IN THE TABLES CONTAINED ON THIS STATEMENT OF SPECIAL INSPECTIONS. 5. AT THE CONCLUSION OF CONSTRUCTION, A FINAL REPORT DOCUMENTING REQUIRED SPECIAL INSPECTIONS AND CORRECTION OF PREVIOUSLY NOTED DISCREPANCIES WILL BE SUBMITTED TO THE PARTIES IDENTIFIED IN ITEM 4 ABOVE. SPECIAL INSPECTIONS FOR WIND & SEISMIC RESISTANCE 1. SPECIAL INSPECTION FOR WIND RESISTANCE PER OSSC SECTION 1705.10 : ARE NOT APPLICABLE TO THIS PROJECT 2. SPECIAL INSPECTION REQUIREMENTS FOR SEISMIC RESISTANCE IN ACCORDANCE WITH OSSC SECTION 1705.11 ARE NOT APPLICABLE TO THIS PROJECT. DESIGN CRITERIA 2014 OREGON STRUCTURAL SPECIALTY CODE (2014 OSSC) (2012 INTERNATIONAL BUILDING CODE AS AMENDED BY THE STATE OF OREGON) THE BASIC LOAD COMBINATIONS (ASD) PER 1605.3.1 HAVE BEEN USED FOR THE STRUCTURAL DESIGN; EXCEPT CONCRETE ELEMENTS HAVE BEEN DESIGNED USING THE BASIC LOAD COMBINATIONS PER 1605.2 (LRFD). STRUCTURAL CRITERIA PER OSSC CHAPTER 16 1603.1.1 FLOOR LIVE LOAD: 100 psf. (SLAB ON GRADE) 1603.1.2 ROOF LIVE LOAD: 20 psf. 1603.1.3 ROOF SNOW LOAD: GROUND SNOW LOAD, P g = 60 psf DESIGN SNOW LOAD, P f = 60 psf SNOW EXPOSURE FACTOR, C e = 1.0 SNOW LOAD IMPORTANCE FACTOR, Is = 1.0 THERMAL FACTOR, C t = 1.0 1603.1.4 WIND DESIGN DATA: ULTIMATE DESIGN WIND SPEED V ult (3-SECOND GUST), 120 mph RISK CATEGORY, = II WIND IMPORTANCE FACTOR, Iw = 1.00 WIND EXPOSURE, = C INTERNAL PRESSURE COEFFICIENT = ± 0.18 DESIGN WIND PRESSURE = 24 psf (ASD) 1603.1.5 EARTHQUAKE DESIGN DATA: RISK CATEGORY: II SEISMIC IMPORTANCE FACTOR, I E = 1.00 MAPPED SPECTRAL RESPONSE ACCELERATION, Ss = 0.778g MAPPED SPECTRAL RESPONSE ACCELERATION, S 1 = 0.409g SITE CLASS: D SPECTRAL RESPONSE COEFFICIENT, S DS = 0.617g SPECTRAL RESPONSE COEFFICIENT, S D1 = 0.433g SEISMIC DESIGN CATEGORY: D BASIC SEISMIC-FORCE-RESISTING SYSTEM: SPECIAL REINFORCED MASONRY SHEARWALLS AND INTERMEDIATE MOMENT FRAMES DESIGN BASE SHEAR = 95 K SEISMIC RESPONSE COEFFICIENT, Cs = 0.19W RESPONSE MODIFICATION FACTOR, R = 4.5 ANALYSIS PROCEDURE USED: EQUIVALENT LATERAL FORCE PROCEDURE. 11 DESIGN CRITERIA 10 DRAWING LEGEND GEOTECHNICAL OBSERVATION 1. PLACEMENT AND COMPACTION OF ENGINEERED BACKFILL PRIOR TO PLACEMENT OF ANY REINFORCING STEEL. S1.1 1 1 XX DRAWING LEGEND MARK DESCRIPTION SECTION CUT GRID REVISION 1 FOOTING A CONCRETE MASONRY S1.1 1 ELEVATION CALLOUT S1.1 1 DETAIL CALLOUT MARK DESCRIPTION ELEVATION WINDOW KEYED NOTE EXTENTS OF INFILL 18 STRUCTURAL OBSERVATION SPECIAL INSPECTIONS REQUIRED 1. REINFORCING STEEL. (PERIODIC) 2. EMBEDDED BOLTS. (PERIODIC) 3. DURING CONCRETE PLACEMENT. (CONTINUOUS) 4. STEEL FABRICATION AND ERECTION. (PERIODIC) 5. HIGH-STRENGTH BOLTING. (PERIODIC) 6. PAN DECK INSTALLATION. (PERIODIC) 7. CMU DURING LAYUP (CONTINUOUS) 8. CMU REINFORCING. (PERIODIC) 9. CMU GROUTING. (CONTINUOUS) STRUCTURAL OBSERVATIONS REQUIRED 1. REINFORCING PRIOR TO CONCRETE PLACEMENT. 2. EMBEDS PRIOR TO CONCRETE PLACEMENT. 3. DURING PLACEMENT OF CONCRETE. 4. ENGINEERED FILL. © 2017 JOHNSON BRODERICK ENGINEERING. No part of this document can be reproduced without the written permission from JBE, [ 325 WEST 13TH AVENUE EUGENE OREGON, 97401. (541)338-9488 or fax (541)338-9483 ] Project: THE DOCUMENT AND THE DESIGNS INCORPORATED HEREIN ARE THE PROPERTY OF JOHNSON BRODERICK ENGINEERING, LLC, AND IS NOT TO BE USED, IN WHOLE OR PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION FROM THE PRINCIPALS OF JOHNSON BRODERICK ENGINEERING JBE JOHNSON BRODERICK ENGINEERING Civil and Structural Engineers 325 W. 13th Ave Eugene, Or 97401-3402 Tel (541) 338-9488 Fax (541) 338-9483 www.JBE.US.com Project No: Drawn By: Sheet title: Checked By: Date: Issued Description Mark By 17095.01 JW AMB S0.0 CONSTRUCTION SET 4/20/2018 WRS 4/20/2018 STRUCTURAL COVER & INDEX KVAL ADDITIONS & ALTERATIONS 4575 BLANTON ROAD EUGENE, OR, 97405 14 NOT USED 15 NOT USED CONCRETE DOORS S0.0 STRUCTURAL COVER & INDEX X S0.1 MATERIAL SPECIFICATIONS X S2.0 FOUNDATION PLAN X S2.1 ROOF FRAMING PLAN X S3.0 MOMENT FRAME ELEVATIONS X S4.0 BUILDING SECTIONS X S4.1 NOT USED S4.2 NOT USED S5.0 CONCRETE DETAILS X S5.1 CONCRETE DETAILS X S5.2 CONCRETE DETAILS X S7.0 STEEL DETAILS X S7.1 STEEL DETAILS X S7.2 STEEL DETAILS X S7.3 JOIST LOADING TABLE X S7.4 NOT USED S7.5 COLD-FORM DETAILS X S8.0 CMU DETAILS X SITE MAP 3 AREA OF WORK ISSUED FOR PERMIT \\JBE-06\JBE - Projects\17095.xx - Sanders Design\17095.01 - 4575 Blanton Road\Drawings\Cad\CONST SET 4-20-2018\17095.01 - KVAL Addition - S0.0 S0.1.dwg, 4/23/2018 8:25:36 AM

Upload: others

Post on 07-Jun-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: THE DOCUMENT AND THE DESIGNS INCORPORATED HEREIN … · 2018-04-24 · system at the construction stages indicated in the structural observation table and at completion of the structural

@ AT

AB ANCHOR BOLTABV ABOVEATR ALL-THREAD RODARCH ARCHITECTURAL

BC BOTTOM CHORDBLDG BUILDINGBLKG BLOCKINGBM BEAMBN BOUNDARY NAILINGBOT BOTTOMBO BOTTOM OFBOS BOTTOM OF STEEL

℄ CENTER LINECIP CAST-IN-PLACECLG CEILINGCLR CLEARCJ CONTROL JOINTCMU CONCRETE MASONRY UNITCOL COLUMNCONC CONCRETECONT CONTINUOUSCP CONTROL POINT

(D) DEMOLISHDBL DOUBLEDEFL DEFLECTIONDET DETAILDIA DIAMETERDO DITTODWG DRAWING

(E) EXISTINGE EASTEA EACHES EACH SIDEEN EDGE NAILEL ELEVATION, END LENGTHEW EACH WAYEJ EXPANSION JOINTEQ EQUALEXP ANC EXPANSION ANCHOREXT EXTERIOR

FE FIRE EXINGUISHERFEC FIE EXTINGUISHER CABINETFS FAR SIDEFDN FOUNDATIONFIN FINISHFG FINISHED GRADEFLR FLOORFO FACE OFFOC FACE OF CONCRETEFOF FACE OF FRAMINGFOM FACE OF MASONRYFOS FACE OF STUDFTG FOOTINGFOCMU FACE OF CMU

GA GAUGEGB GRADE BEAMGL GLUE LAMINATED (BEAM)GWG GYPSUM BOARDGYP GYPSUM

HCA HEADED CONC ANCHOR (STUD)HDR HEADERH, HORIZ HORIZONTALHDG HOT DIPPED GALVANIZEDHS HIGH STRENGTHHSB HIGH STRENGTH BOLTSHSS HOLLOW STRUCTURAL SECTION

INT INTERIOR

LLH LONG LEG HORIZONTALLSL LAMINATED STAND LUMBERLLV LONG LEG VERTICAL

LONG LONGITUDINALLSH LONG SLOTTED HOLELVL LAMINATED VENEER LUMBER

MFR MANUFACTURERMB MACHINE BOLTSMAX MAXIMUMMTL METALMIN MINIMUMMISC MISCELLANEOUS

(N) NEWN / NO. NORTHNS NEAR SIDENTS NOT TO SCALE

OC ON CENTEROPG OPENINGOH OPPOSITE HANDOP OPPOSITEOSB ORIENTED STRAND BOARDOSSC OREGON STRUCTURAL SPECIALTY CODEO/ OVER

PSL PARALLEL STRAND LUMBER⅊ PLATE (STEEL)PLY PLYWOODPMJ PRE-MOLDED JOINT FILLERPT PRESSURE TREATED

REINF REINFORCEMENTREQ'D REQUIREDRJ ROUGHENED CONSTRUCTION JOINTRO ROUGH OPENINGRS ROUGH SAWN

S / SO. SOUTHSAD SEE ARCHITECTURAL DRAWINGSC SLIP CRITICALSCHED SCHEDULESDWS SELF-DRILLING WOOD SCREWSGD SEE GEOTECH DESIGN / REPORTSHTH'G SHEATHINGSIM SIMILARSOG SLAB ON GRADESPEC SPECIFICATIONSQ SQUARESSH SHORT SLOTTED HOLESS STAINLESS STEELSYMM SYMMETRICAL

TBD TO BE DETERMINEDTC TOP CHORDTN TOE NAILT&B TOP AND BOTTOMTO TOP OFTOC TOP OF CONCRETETOF TOP OF FRAMINGTOFS TOP OF FLOOR SHEATHINGTOM TOP OF MASONRYTOS TOP OF STEELTRANS TRANSVERSETYP TYPICAL

UNO UNLESS NOTED OTHERWISEUT ULTRASONIC TESTING

VERT VERTICAL

W WESTWA WALL ASSEMBLYW/ WITHW/O WITHOUTWP WORK POINT, WATERPROOFING

1SHEET INDEX5ABBREVIATIONS9SUBMITTALS13SPECIAL INSPECTION17SPECIAL INSPECTION21GENERAL NOTES

GENERAL

1. ALL CONSTRUCTION TESTING AND INSPECTIONS SHALL CONFORM TO THE 2012 IBC AND2014 OSSC.

2. CONSTRUCTION LIABILITY: CONSTRUCTION CONTRACTOR AND HIS/HERSUBCONTRACTORS AGREE THAT IN ACCORDANCE WITH GENERALLY ACCEPTEDCONSTRUCTION PRACTICES, CONSTRUCTION CONTRACTOR AND HIS/HERSUBCONTRACTORS WILL BE REQUIRED TO ASSUMED SOLE AND COMPLETERESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OFTHE PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THISREQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND NOT LIMITED TO NORMALWORKING HOURS, AND CONSTRUCTION CONTRACTOR AND HIS/HER SUBCONTRACTORSFURTHER AGREE TO DEFEND, INDEMNIFY, AND HOLD DESIGN PROFESSIONAL HARMLESSFROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THEPERFORMANCE OF WORK ON THE PROJECT EXCEPT LIABILITY FROM THE SOLENEGLIGENCE OF THE DESIGN PROFESSIONAL.

3. DURING THE CONSTRUCTION PERIOD, THE CONTRACTOR SHALL BE RESPONSIBLE FORTHE SAFETY OF THE BUILDING. THE CONTRACTOR SHALL PROVIDE ADEQUATE SHORING,BRACING, AND GUYS IN ACCORDANCE WITH ALL NATIONAL, STATE, AND LOCAL SAFETYORDINANCES.

4. THE STABILITY AND INTEGRITY OF THE EXISTING STRUCTURES DURING CONSTRUCTIONSHALL BE MAINTAINED AT LEVELS GENERALLY ACCEPTABLE WITHIN THE CONSTRUCTIONINDUSTRY BY THE USE OF BRACING, SHORING AND UNDERPINNING UNTIL THE PROPOSEDSTRUCTURE MODIFICATIONS ARE COMPLETED, IN NO CASE SHALL THE EXISTINGSTRUCTURES BE ALLOWED TO BECOME UNSAFE DURING CONSTRUCTION.

5. THE BRACING AND SHORING SYSTEMS REQUIRED TO PROVIDE TEMPORARY SUPPORT OFTHE STRUCTURE DURING CONSTRUCTION SHALL BE DESIGNED TO SUPPORT THE DEAD,LIVE, SOIL, EARTHQUAKE, AND WIND LOADS THAT MAY BE IMPOSED ON THE STRUCTUREDURING CONSTRUCTION, IN ACCORDANCE WITH INDUSTRY STANDARDS AND GENERALLYACCEPTED ENGINEERING PRINCIPLES.

6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTINGUTILITIES WHETHER SHOWN HEREIN OR NOT, AND TO PROTECT THEM FROM DAMAGE. THECONTRACTOR SHALL BEAR ALL EXPENSE OF REPAIR OR REPLACEMENT IN CONJUNCTIONWITH THE PERFORMANCE OF THIS WORK.

7. DO NOT SCALE THE DRAWINGS.

8. WHERE A CONFLICT OCCURS BETWEEN SPECIFICATIONS, NOTES ON THE DRAWINGS,GENERAL NOTES, AND SPECIFIC DETAILS, THE MORE RESTRICTIVE SHALL GOVERN.

9. OMISSIONS OR DISCREPANCIES BETWEEN THE VARIOUS ELEMENTS OF THE CONTRACTDRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER BEFORE PROCEEDING WITH THE WORK.

10. VERIFY ALL EXISTING FEATURES AND CONDITIONS (DIMENSIONS, ELEVATIONS, ETC.) UPONWHICH THESE DRAWINGS RELY.

11. CONTRACTOR TO VERIFY ALL DIMENSIONS AND ELEVATIONS SHOWN ON STRUCTURAL,CIVIL, ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE DRAWINGS.NOTIFY ENGINEER OF ANY CONFLICTING INFORMATION PRIOR TO BEGINNINGCONSTRUCTION.

12. ALL DETAILS ARE TYPICAL. FOR CONDITIONS NOT SPECIFICALLY SHOWN, PROVIDEDETAILS SIMILAR TO THOSE SHOWN, SUBJECT TO ENGINEER'S REVIEW. FOR CONDITIONSWITH NO SIMILAR DETAIL SHOWN. CONTRACTOR TO SUBMIT DETAIL FOR ENGINEERSAPPROVAL PRIOR TO USE.

13. COORDINATE STRUCTURAL WORK WITH THE CIVIL, ARCHITECTURAL, MECHANICAL,ELECTRICAL, PLUMBING, & FIRE WORK DOCUMENTS.

14. OPENINGS IN FLOORS, BEAMS, OR JOIST LARGER THAN THOSE SHOWN ON TYPICAL DETAILS OF STRUCTURAL DRAWINGS SHALL BE REVIEWED BY THE ENGINEER OF RECORDBEFORE PROCEEDING WITH THE WORK.

15. ALL CONSTRUCTION AND POUR JOINTS TO BE APPROVED BY THE ENGINEER.

16. VIBRATION EFFECTS OF MECHANICAL EQUIPMENT ARE NOT CONSIDERED TO BE DETRIMENTAL TO THE STRUCTURAL DESIGN AND HAVE NOT BEEN CONSIDERED BY THESTRUCTURAL ENGINEER.

17. ITEMS IDENTIFIED BY TRADE NAME ARE INDICATIVE OF A LEVEL OF PERFORMANCE OR AGRADE OF MATERIAL. IN ALL SUCH CASES THE PHRASE "OR APPROVED EQUAL" SHALLAPPLY. SUBSTITUTES SHALL BE SUBMITTED FOR APPROVAL PRIOR TO USE.

18. NO CONSTRUCTION OR ORDERING MATERIALS SHALL TAKE PLACE UNTIL THECONTRACTOR HAS RECEIVED REVIEWED SUBMITTALS BY THE ENGINEER.

19. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS AS REQUIRED BY THESE DOCUMENTSAFTER THE CONTRACTOR HIMSELF HAS REVIEWED THE SUBMITTALS. ENGINEERINGREVIEW OF ANY SUBMITTALS IS ONLY FOR COMPLIANCE WITH GENERAL STRUCTURALREQUIREMENT AND IS SPECIFICALLY NOT FOR DIMENSIONAL OR QUANTITATIVEINFORMATION.

20. THE SUBMITTALS SHALL SHOW LAYOUT, SIZE OF MEMBERS, CONNECTION DETAILS ANDCONSTRUCTION SEQUENCE FOR ALL BRACING AND SHORING SYSTEMS. THE SUBMITTALSSHALL BE ACCOMPANIED BY STRUCTURAL CALCULATIONS SIGNED BY A REGISTEREDSTRUCTURAL ENGINEER. THE ENGINEER SHALL ALSO PROVIDE A LETTER STATING THATHE/SHE HAS REVIEWED THE SUBMITTALS FOR COMPLETENESS AND SHALL PERFORMFIELD VISITS AS REQUIRED IN ORDER TO CHECK GENERAL CONFORMANCE OF THECONSTRUCTION TO THE CALCULATIONS.

STRUCTURAL OBSERVATION

1. STRUCTURAL OBSERVATION WILL BE IN ACCORDANCE WITH THE 2014 OSSC TOGETHERWITH LOCAL AND STATE AMENDMENTS, REFER TO PROJECT SPECIFIC NOTES ON THISSHEET.

2. ONSITE STRUCTURAL OBSERVATION WILL BE PERFORMED FOR EACH IDENTIFIED SEISMICFORCE-OR WIND FORCE-RESISTING SYSTEM, INCLUDING FOUNDATIONS ANDCONNECTIONS. REFER TO THE INDIVIDUAL FACILITY PLANS FOR THE BASIC SEISMIC- ANDWIND-RESISTING SYSTEMS FOR THE STRUCTURES INCLUDED IN THE WORK.

3. STRUCTURAL OBSERVATION WILL BE PERFORMED BY A REGISTERED PROFESSIONALENGINEER FOR GENERAL CONFORMANCE TO THE APPROVED CONSTRUCTIONDOCUMENTS. STRUCTURAL OBSERVATION DOES NOT PRECLUDE OR WAIVE THERESPONSIBILITY FOR ANY REQUIRED INSPECTIONS OR INSPECTION BY THE BUILDINGOFFICIAL.

4. STRUCTURAL OBSERVATION REPORTS, NOTING ANY DEFICIENCIES IN OBSERVEDCONSTRUCTION, WILL BE DELIVERED TO THE CONTRACTOR, BUILDING OFFICIAL, ANDOWNER FOLLOWING EACH OBSERVATION. THE CONTRACTOR WILL BE NOTIFIED ON-SITEOR BY PHONE OR EMAIL WITHIN 24 HOURS UPON FINDING ANY DEFICIENCIES.

5. AT THE CONCLUSION OF CONSTRUCTION, A WRITTEN STATEMENT IS REQUIRED TOVERIFY THAT THE STRUCTURAL OBSERVATION SITE VISITS WERE MADE AND WHETHERTHERE REMAIN ANY STRUCTURAL DEFICIENCIES THAT HAVE NOT BEEN RESOLVED.

6. STRUCTURAL OBSERVATION WILL INCLUDE VISUAL OBSERVATION OF THE STRUCTURALSYSTEM AT THE CONSTRUCTION STAGES INDICATED IN THE STRUCTURAL OBSERVATIONTABLE AND AT COMPLETION OF THE STRUCTURAL SYSTEM FOR EACH STRUCTURECONTAINED IN THE WORK. THE CONTRACTOR SHALL SCHEDULE AND FACILITATESTRUCTURAL OBSERVATION FOR THE LINE ITEMS LISTED BELOW.

SUBMITTALS

1. BACKFILL MATERIAL GRADING.2. CONCRETE MIX.3. REBAR SHOP DRAWINGS.4. EMBEDDED BOLTS.5. STRUCTURAL STEEL SHOP DRAWINGS.6. OPEN-WEB SHOP DRAWINGS.7. PAN DECK SHOP DRAWINGS.8. COLD-FORMED FRAMING & WINDOW WALL SYSTEM.9. CMU REINFORCING.10. CMU WALL ELEVATIONS.11. CMU MORTAR MIX.12. CMU GROUT MIX.13. ROOF BALLAST14. ROOF TOP UNITS15. SUSPENDED CEILING SYSTEM

SPECIAL INSPECTIONS

1. SPECIAL INSPECTION WILL BE IN ACCORDANCE WITH THE 2014 IBC SECTION 1704TOGETHER WITH LOCAL AND STATE AMENDMENTS. IF APPLICABLE, REFER TO THETABLES CONTAINED ON THESE GENERAL SHEETS FOR PROJECT SPECIFIC INSPECTIONTYPES AND FREQUENCIES.

2. SPECIAL INSPECTION WILL BE PROVIDED BY A CERTIFIED AND QUALIFIED INSPECTORAND ASSOCIATED TESTING WILL BE PERFORMED BY AN APPROVED ACCREDITEDAGENCY. THE OWNER WILL SECURE AND PAY FOR THE SERVICES OF THE AGENCY TOPERFORM ALL SPECIAL INSPECTION AND ASSOCIATED TESTS. INSPECTORS FOR EACHSYSTEM AND MATERIAL WILL BE INTERNATIONAL CODE COUNCIL (ICC) CERTIFIED OROTHERWISE APPROVED BY THE BUILDING OFFICIAL.

3. THE SPECIAL INSPECTOR WILL OBSERVE THE INDICATED WORK FOR COMPLIANCEWITH THE APPROVED CONTRACT DOCUMENTS AND SUBMIT RECORDS OF INSPECTION.ALL DISCREPANCIES WILL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THECONTRACTOR FOR CORRECTION.

4. SPECIAL INSPECTION AND ASSOCIATED TESTING REPORTS WILL BE SUBMITTED TO THEDESIGN TEAM, CONTRACTOR, BUILDING OFFICIAL, AND OWNER WITHIN ONE WEEK OFINSPECTION OR WITHIN ONE WEEK OF TEST COMPLETION. INSPECTIONS FOR WHICHREPORTING WILL BE REQUIRED ARE NOTED IN THE TABLES CONTAINED ON THISSTATEMENT OF SPECIAL INSPECTIONS.

5. AT THE CONCLUSION OF CONSTRUCTION, A FINAL REPORT DOCUMENTING REQUIREDSPECIAL INSPECTIONS AND CORRECTION OF PREVIOUSLY NOTED DISCREPANCIESWILL BE SUBMITTED TO THE PARTIES IDENTIFIED IN ITEM 4 ABOVE.

SPECIAL INSPECTIONS FOR WIND & SEISMIC RESISTANCE

1. SPECIAL INSPECTION FOR WIND RESISTANCE PER OSSC SECTION 1705.10 : ARE NOTAPPLICABLE TO THIS PROJECT

2. SPECIAL INSPECTION REQUIREMENTS FOR SEISMIC RESISTANCE IN ACCORDANCEWITH OSSC SECTION 1705.11 ARE NOT APPLICABLE TO THIS PROJECT.

DESIGN CRITERIA

2014 OREGON STRUCTURAL SPECIALTY CODE (2014 OSSC)(2012 INTERNATIONAL BUILDING CODE AS AMENDED BY THE STATE OF OREGON) THE BASIC

LOAD COMBINATIONS(ASD) PER 1605.3.1 HAVE BEEN USED FOR THE STRUCTURAL DESIGN; EXCEPT CONCRETE

ELEMENTS HAVE BEENDESIGNED USING THE BASIC LOAD COMBINATIONS PER 1605.2 (LRFD).

STRUCTURAL CRITERIA PER OSSC CHAPTER 16

1603.1.1 FLOOR LIVE LOAD: 100 psf. (SLAB ON GRADE)

1603.1.2 ROOF LIVE LOAD: 20 psf.

1603.1.3 ROOF SNOW LOAD:GROUND SNOW LOAD, Pg = 60 psfDESIGN SNOW LOAD, Pf = 60 psfSNOW EXPOSURE FACTOR, Ce = 1.0SNOW LOAD IMPORTANCE FACTOR, Is = 1.0THERMAL FACTOR, Ct = 1.0

1603.1.4 WIND DESIGN DATA:ULTIMATE DESIGN WIND SPEED Vult (3-SECOND GUST), 120 mphRISK CATEGORY, = IIWIND IMPORTANCE FACTOR, Iw = 1.00WIND EXPOSURE, = CINTERNAL PRESSURE COEFFICIENT = ± 0.18DESIGN WIND PRESSURE = 24 psf (ASD)

1603.1.5 EARTHQUAKE DESIGN DATA:RISK CATEGORY: IISEISMIC IMPORTANCE FACTOR, IE = 1.00MAPPED SPECTRAL RESPONSE ACCELERATION, Ss = 0.778gMAPPED SPECTRAL RESPONSE ACCELERATION, S1 = 0.409gSITE CLASS: DSPECTRAL RESPONSE COEFFICIENT, SDS = 0.617gSPECTRAL RESPONSE COEFFICIENT, SD1 = 0.433gSEISMIC DESIGN CATEGORY: DBASIC SEISMIC-FORCE-RESISTING SYSTEM: SPECIAL REINFORCED MASONRY SHEARWALLS

AND INTERMEDIATE MOMENT FRAMESDESIGN BASE SHEAR = 95 KSEISMIC RESPONSE COEFFICIENT, Cs = 0.19WRESPONSE MODIFICATION FACTOR, R = 4.5ANALYSIS PROCEDURE USED: EQUIVALENT LATERAL FORCE PROCEDURE.

11DESIGN CRITERIA

10DRAWING LEGEND

GEOTECHNICAL OBSERVATION

1. PLACEMENT AND COMPACTION OF ENGINEERED BACKFILL PRIOR TO PLACEMENT OFANY REINFORCING STEEL.

S1.11

1

XX

DRAWING LEGENDMARK DESCRIPTION

SECTION CUT

GRID

REVISION1

FOOTINGA

CONCRETE MASONRY

S1.11 ELEVATION CALLOUT

S1.11

DETAIL CALLOUT

MARK DESCRIPTION

ELEVATION

WINDOW

KEYED NOTE

EXTENTS OF INFILL

18STRUCTURAL OBSERVATION

SPECIAL INSPECTIONS REQUIRED

1. REINFORCING STEEL. (PERIODIC)

2. EMBEDDED BOLTS. (PERIODIC)

3. DURING CONCRETE PLACEMENT. (CONTINUOUS)

4. STEEL FABRICATION AND ERECTION. (PERIODIC)

5. HIGH-STRENGTH BOLTING. (PERIODIC)

6. PAN DECK INSTALLATION. (PERIODIC)

7. CMU DURING LAYUP (CONTINUOUS)

8. CMU REINFORCING. (PERIODIC)

9. CMU GROUTING. (CONTINUOUS)

STRUCTURAL OBSERVATIONS REQUIRED

1. REINFORCING PRIOR TO CONCRETE PLACEMENT.2. EMBEDS PRIOR TO CONCRETE PLACEMENT.3. DURING PLACEMENT OF CONCRETE.4. ENGINEERED FILL.

© 2017 JOHNSON BRODERICK ENGINEERING. No part of this document can be reproduced without the written permission from JBE, [ 325 WEST 13TH AVENUE EUGENE OREGON, 97401. (541)338-9488 or fax (541)338-9483 ]

Proje

ct:

THE DOCUMENT AND THE DESIGNS

INCORPORATED HEREIN ARE THE

PROPERTY OF JOHNSON BRODERICK

ENGINEERING, LLC, AND IS NOT TO BE

USED, IN WHOLE OR PART, FOR ANY

OTHER PROJECT WITHOUT THE

WRITTEN AUTHORIZATION FROM THE

PRINCIPALS OF JOHNSON BRODERICK

ENGINEERING

JBE

JOHN

SON

BROD

ERIC

KEN

GINE

ERIN

GC

iv

il an

d S

tru

ctu

ral E

ng

in

eers

325 W

. 13th

Ave

Euge

ne, O

r 974

01-3

402

Tel (5

41) 3

38-9

488

Fax (

541)

338-

9483

www.

JBE.

US.co

m

Project No:

Drawn By:

Sheet title:

Checked By:

Date:

Issue

dDe

scrip

tion

Mark

By

17095.01

JW

AMB

S0.0

CONS

TRUC

TION

SET

4/20/2

018WR

S

4/20/2018

STRUCTURALCOVER &

INDEX

KVAL

ADD

ITIO

NS &

ALT

ERAT

IONS

4575

BLA

NTON

ROA

DEU

GENE

, OR,

9740

5

14NOT USED

15NOT USED

CONCRETEDOORS

S0.0 STRUCTURAL COVER &INDEX X

S0.1 MATERIALSPECIFICATIONS X

S2.0 FOUNDATION PLAN X

S2.1 ROOF FRAMING PLAN X

S3.0 MOMENT FRAMEELEVATIONS X

S4.0 BUILDING SECTIONS X

S4.1 NOT USED

S4.2 NOT USED

S5.0 CONCRETE DETAILS X

S5.1 CONCRETE DETAILS X

S5.2 CONCRETE DETAILS X

S7.0 STEEL DETAILS X

S7.1 STEEL DETAILS X

S7.2 STEEL DETAILS X

S7.3 JOIST LOADING TABLE X

S7.4 NOT USED

S7.5 COLD-FORM DETAILS X

S8.0 CMU DETAILS X

SITE MAP 3

AREA OF WORK

ISSU

ED F

OR P

ERMI

T

\\JBE

-06\J

BE -

Proje

cts\17

095.x

x - S

ande

rs De

sign\1

7095

.01 -

4575

Blan

ton R

oad\D

rawi

ngs\C

ad\C

ONST

SET

4-20

-201

8\170

95.01

- KV

AL A

dditio

n - S

0.0 S

0.1.dw

g, 4/2

3/201

8 8:25

:36 A

M

Page 2: THE DOCUMENT AND THE DESIGNS INCORPORATED HEREIN … · 2018-04-24 · system at the construction stages indicated in the structural observation table and at completion of the structural

WELDING

1. ALL WELDING SHALL BE PERFORMED BY CERTIFIED WELDERS PER AWS “STANDARDQUALIFICATION PROCEDURE” TO PERFORM THE TYPE OF WORK REQUIRED. ALL WELDINGSHALL BE IN ACCORDANCE WITH THE CURRENT AWS WELDING CODE.

2. WELDING ELECTRODES SHALL BE E70 SERIES FOR A36, A572 AND A992 MATERIAL, AND E80SERIES FOR A705 REINFORCING STEEL.

3. TACK WELDS, AIR-ARC GOUGING AND FLAME CUTTING SHALL NOT BE PERFORMEDWITHOUT ADEQUATE PREHEAT OR INCORPORATION INTO THE FINAL WELD.

4. STEEL FABRICATOR TO SUBMIT WELDING PROCEDURE TO OWNER'S TESTING AGENCY ANDTHE ARCHITECT FOR REVIEW BEFORE FABRICATION.

MANUFACTURED PRODUCTS

1. THE FOLLOWING MANUFACTURED PRODUCTS SHALL BE INSTALLED IN COMPLIANCE WITHTHE ASSOCIATED ICC-ES EVALUATION REPORT LISTED BELOW:

PRODUCT REPORTA. SIMPSON CONNECTORS ICC-ES ESR-2523B. SIMPSON CONNECTORS IAPMO-UES ER-102C. SIMPSON SDS ICC-ES ESR-2236

SOIL, SUBGRADE, AND FOUNDATION PREPARATION

1. THE FOUNDATION DESIGN IS BASED UPON THE 2014 OSSC AND THE SOILS REPORTPREPARED BY K&A ENGINEERING, DATED APRIL 5,2016

2. REMOVE ALL LOOSE, DISTURBED, ORGANIC, OR CLAY SOIL FROM UNDERNEATH ALL NEWFOOTINGS.

3. LOCATE THE BOTTOM OF ALL FOOTINGS A MINIMUM OF 18" BELOW LOWEST ADJACENTFINAL GRADE UNLESS OTHERWISE NOTED.

4. PROVIDE MINIMUM 8" COMPACTED CRUSHED ROCK BASE AT FOOTING AND SLAB.

5. ALL WALL FOOTINGS SHALL BE CENTERED BELOW WALL/COLUMN ABOVE UNLESSOTHERWISE NOTED.

6. ENGINEER OR ARCHITECT TO OBSERVE PRIOR TO PLACEMENT OF CRUSHED ROCK FILL.

7. ADDITIONAL REQUIREMENTS PER SOILS REPORT IN NOTE 1.

REINFORCING STEEL

1. ALL REINFORCING STEEL SHALL BE PLACED IN CONFORMANCE TO “BUILDING CODEREQUIREMENTS FOR REINFORCED CONCRETE” (ACI 318, LATEST APPROVED EDITION),AND THE “ACI DETAILING MANUAL” AS MODIFIED BY THE PROJECT DRAWINGS ANDSPECIFICATIONS.

2. REINFORCING STEEL TO BE ASTM A615, GRADE 60 DEFORMED BARS.

3. ALL LAP SPLICES SHALL BE 2'-0” MINIMUM UNLESS OTHERWISE NOTED. MAINTAIN 1-1/2”CLEAR MINIMUM BETWEEN PARALLEL BARS.

4. ALL REINFORCING STEEL AND EMBEDMENTS TO BE HELD SECURELY IN PLACE PRIOR TOPLACING CONCRETE OR GROUTING. PROVIDE SUFFICIENT SUPPORTS TO ALLOWWALKING ON REINFORCEMENT. NO BRICK OR POROUS MATERIAL SHALL BE USED TOSUPPORT REINFORCING.

5. REINFORCEMENT SHALL BE PLACED IN RELATIVE POSITION SHOWN ON THE DRAWINGS.NO SPLICES IN REINFORCING WILL BE PERMITTED UNLESS SHOWN ON THE STRUCTURALDRAWING OR APPROVED BY THE STRUCTURAL ENGINEER.

6. PROVIDE FOUNDATION DOWELS TO MATCH SIZE AND SPACING OF WALL OR COLUMNREINFORCEMENT. EXTEND DOWELS LAP SPLICE LENGTH INTO WALL OR COLUMN ANDTERMINATE WITH STANDARD HOOK 3” ABOVE BOTTOM OF FOOTING, UNLESS OTHERWISENOTED. PROVIDE CONTINUOUS REINFORCEMENT WHEREVER POSSIBLE.

7. REINFORCING STEEL SHALL HAVE THE FOLLOWING CONCRETE COVER, BUT NOT LESSTHAN ONE BAR DIAMETER UNLESS OTHERWISE NOTED:

A. CONCRETE CAST AND PERMANENTLY EXPOSED TO EARTH (NOT FORMED): 3"

B. CONCRETE NOT EXPOSED TO WEATHER OR NOT IN CONTACT WITH THE GROUND:112"

9. REINFORCING BARS SHALL NOT BE REBENT WITHOUT THE APPROVAL OF THESTRUCTURAL ENGINEER.

10. MECHANICAL SPLICES IN REINFORCING SHALL DEVELOP 125% OF THE REINFORCING.MECHANICAL SPLICES SHALL NOT BE USED WITHOUT PRIOR APPROVAL OF THESTRUCTURAL ENGINEER.

11. SPLICES IN ADJACENT HORIZONTAL WALL REINFORCING BARS SHALL BE STAGGERED4'-0” MINIMUM UNLESS OTHERWISE NOTED. PROVIDE DOWELS IN FOOTING AND/ORGRADE BEAMS THE SAME SIZE AND NUMBER AS VERTICAL WALL OR COLUMNREINFORCING. DOWELS SHALL HAVE A MINIMUM PROJECTION EQUAL TO STANDARD LAPSPLICE UNLESS OTHERWISE NOTED.

12. WELDING OF REINFORCING ALLOWED ONLY WHERE SPECIFIED ON DRAWINGS.

13. ALL BOLTS SHALL BE SECURED WITH TEMPLATE.

CONCRETE

1. ALL CONCRETE SHALL BE MIXED AND PLACED IN ACCORDANCE WITH ACI 318 MOSTRECENT EDITION. USE MIXES WITH MAXIMUM AGGREGATE SIZE APPROPRIATE FOR FORMAND REBAR CLEARANCES TO BE ENCOUNTERED. (SEE ACI.)

2. THE PROPOSED MATERIALS AND MIX DESIGN SHALL BE FULLY DOCUMENTED ANDSUBMITTED FOR THE ENGINEERS REVIEW.

3. CONCRETE SHALL HAVE THE FOLLOWING PROPERTIES

4. SCHEDULING OF WORK MAY REQUIRE DESIGN STRENGTH IN LESS THAN 28 DAYS.

5. CEMENT SHALL BE IN ACCORDANCE WITH THE STANDARD SPECIFICATIONS FORPORTLAND CEMENT PER ASTM DESIGNATION C150, TYPE II.

6. CONSTRUCTION JOINTS SHALL BE THOROUGHLY ROUGHENED BY SAND BLASTING ORMECHANICAL MEANS. CLEAN BEFORE PLACEMENT. PLACE CONCRETE TO AVOIDCONSTRUCTION JOINTS.

7. ALL CONCRETE TO BE REINFORCED UNLESS SPECIFICALLY NOTED “NOT REINFORCED”.

8. PROJECTING CORNERS OF BEAMS, WALLS, COLUMNS, ETC., SHALL BE FORMED WITH A ¾”CHAMFER, UNLESS OTHERWISE NOTED ON ARCHITECTURAL DRAWINGS.

9. PRIOR TO PLACING CONCRETE, THE CONTRACTOR SHALL ENSURE THAT ALLEMBEDMENTS, INCLUDING COLUMN ANCHOR BOLTS, ARE PROPERLY LOCATED ANDSECURELY TIED INTO PLACE.

10. SUBMIT LOCATION PLAN FOR ALL PROPOSED JOINTS NOT INDICATED ON DRAWINGS FORAPPROVAL PRIOR TO WORK.

11. CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTION OF CONCRETE FROM FREEZINGBEFORE CURING WHEN POURED IN COLD WEATHER.

12. DIMENSIONS SHOWN OR NOT SHOWN ON PLANS REGARDING CURBS, SLOPES ANDDEPRESSED AREAS AT CONCRETE SLABS SHALL BE VERIFIED WITH ARCHITECTURALDRAWINGS BEFORE POURING CONCRETE.

13. STRIPPING OF FORMS AND SHORING SHALL BE IN STRICT ACCORDANCE WITH ACI 318,LATEST EDITION.

14. PIPES OR DUCTS SHALL NOT BE PLACED IN STRUCTURAL CONCRETE UNLESSSPECIFICALLY DETAILED. REFER TO MECHANICAL AND ELECTRICAL DRAWINGS FORLOCATIONS OF ALL PIPES, CONDUITS, ETC.

15. SLAB PLACEMENT:- FLOOR FLATNESS: FF = 50- FLOOR LEVELNESS: FL = 33

ELEMENT MIN 28-DAY

STRENGTH (PSI)MINIMUM

AGGREGATE SIZE

FOOTINGS 3000 PSI 3/4"

SLAB ON GRADE 4000 PSI 3/4"

RETAINING WALLS 4000 PSI 3/4"

HIGH STRENGTH BOLTS, NUTS, WASHERS AND ANCHOR RODS

1. BOLTS, NUTS, WASHERS AND RODS PERMANENTLY EXPOSED TO WEATHER SHALL BE HOTDIPPED GALVANIZED.

2. BOLTS SHALL BE HEAVY HEX STRUCTURAL BOLTS PER ANSI B1 5.2.1 AND SHALL CONFORMTO THE REQUIREMENTS OF ASTM A490/A325. BOLTS SHALL BE TYPE 1,2 OR 3 AND SHALLBE USED IN A BEARING TYPE CONNECTION UNLESS OTHERWISE NOTED

3. TENSION CONTROL BOLT ASSEMBLIES SHALL CONFORM TO ASTM F1852.

4. DIRECT-TENSION INDICATORS SHALL CONFORM TO ASTM F959.

5. RODS SHALL CONFORM TO ASTM A1554 GR. 36 UNO

6. NUTS SHALL BE AS SHOWN BELOW AND FINISH SHALL MATCH FASTENER.

FASTENER GRADE AND SIZE NUT CLASS NUT STYLE

ASTM A325TYPE 1 AND 2, UNCOATED ASTM A563 - C,C3,D,DH,DH3 HEAVY HEXTYPE 1 AND 2, ZINC COATED ASTM A563 - DH HEAVY HEXTYPE 3, UNCOATED ASTM A563 - C3, DH3 HEAVY HEX

7. WASHERS SHALL BE FLAT, CIRCULAR, RECTANGULAR OR SQUARE BEVELED WASHERSAND SHALL CONFORM TO ASTM F436 TYPE 1. FINISH SHALL MATCH NUT. WASHERS SHALLBE INSTALLED UNDER THE ELEMENT BEING TURNED FOR A325 BOLTS AND UNDER BOTHTHE HEAD AND THE NUT FOR A490 BOLTS. WASHERS OVER OVERSIZED OR SLOTTEDHOLES SHALL ALSO COMPLY WITH RCSC SPECIFICATIONS.

LUMBER

1. ALL LUMBER SHALL BE DOUGLAS FIR, COAST REGION, GRADED IN ACCORDANCE WITH THEWESTERN WOOD PRODUCTS ASSOCIATION.

2. ALL LUMBER TO BE OF THE FOLLOWING GRADES UNLESS OTHERWISE NOTED:

STUDS AND PLATES: #2JOISTS AND RAFTERS: 2X TO 4X SHALL BE #1 AND BETTERBEAMS: 4X OR SMALLER SHALL BE #1 AND BETTER.

6X AND LARGER SHALL BE #1.POSTS AND TIMBERS: 4 X 4 AND LARGER SHALL BE #1 AND BETTER.BLOCKING AND FURRING, ETC.: #2

3. ALL WOOD BEARING ON CONCRETE OR MASONRY SHALL BE PRESSURE TREATEDDOUGLAS FIR.

4. PRESSURE TREATED WOOD SHALL BE DOUGLAS FIR AND SHALL BEAR GRADE STAMP.

5. STRUCTURAL MEMBERS SHALL NOT BE CUT FOR PIPES, CONDUIT, ETC., UNLESS .

6. THE MINIMUM NAILING TO CONNECT WOOD MEMBERS SHALL BE AS SPECIFIED IN TABLE2304.9.1 OF THE 2014 OSSC UNO.

7. ALL LAG SCREWS AND WOOD SCREWS SHALL CONFORM TO ASTM A-36 WITH CUTTHREADS. LAG SCREWS AND WOOD SCREWS SHALL HAVE PREDRILLED PILOT HOLES ASFOLLOWS:

SHANK PORTION - SAME DIAMETER & LENGTH OF SHANKTHREAD PORTION - 0.6 TO 0.75 TIMES THE DIAMETER ON THE THREADS AND SAME LENGTH

8. HOLES FOR BOLTS SHALL BE BORED 1/32” TO 1/16” LARGER THAN NOMINAL BOLTDIAMETER. (THIS INCLUDES HOLES FOR BOLTS IN SILL PLATES.)

9. ALL BOLTS BEARING ON WOOD SHALL HAVE STANDARD CUT WASHERS UNDER HEADAND/OR NUT.

10. ALL BOLTS SHALL BE RETIGHTENED PRIOR TO APPLICATION OF PLASTER, DRYWALL,PLYWOOD, ETC.

11. ALL FRAMING HARDWARE SHALL BE AS MANUFACTURED BY THE SIMPSON COMPANYUNLESS OTHERWISE NOTED.

12. ALL POST CONNECTIONS AT THE TOP SHALL BE SIMPSON 'CCQ' UNLESS OTHERWISENOTED.

13. ALL POST CONNECTIONS TO FOUNDATION OR SLAB SHALL BE SIMPSON 'CBSQ' UNLESSOTHERWISE NOTED.

14. MACHINE APPLIED NAILING:USE OF MACHINE NAILING IS SUBJECT TO A SATISFACTORY JOBSITE DEMONSTRATION FOREACH PROJECT AND THE APPROVAL BY THE PROJECT ARCHITECT OR STRUCTURALENGINEER. THE APPROVAL IS SUBJECT TO CONTINUED SATISFACTORY PERFORMANCE.MACHINE NAILING WILL NOT BE APPROVED IN 5 16" PLYWOOD. IF NAILHEADS PENETRATETHE OUTER PLY MORE THAN WOULD BE NORMAL FOR A HAND HAMMER OR IF MINIMUMALLOWABLE EDGE DISTANCES ARE NOT MAINTAINED THE PERFORMANCE WILL BE DEEMEDUNSATISFACTORY.

STRUCTURAL COMPOSITE LUMBER

1. ALL STRUCTURAL COMPOSITE LUMBER SHALL BE APA STAMPED: LVL (LAMINATED VENEERLUMBER); PSL (PARRALLEL STRAND LUMBER); LSL (LAMINATED STRAND LUMBER).

2. LVL SHALL BE 1.9E MICROLAM AS MANUFACTURED BY WEYERHAEUSER iLEVEL.

3. PSL SHALL BE 2.0E PARALLAM AS MANUFACTURED BY WEYERHAEUSER iLEVEL.

4. LSL SHALL BE 1.55E TIMBERSTRAND AS MANUFACTURED BY WEYERHAEUSER iLEVEL.

STRUCTURAL STEEL

1. STEEL USAGE:

PLATE: ASTM A572, GR. 50.BOLTS: ASTM 325-X UNLESS OTHERWISE NOTEDWIDE FLANGE BEAMS: ASTM A992, GR. 50ANGLE: ASTM A36CHANNEL: ASTM A36ROD: ASTM F1556 GR. 36HSS: ASTM A500 GR. B

2. ALL STRUCTURAL STEEL TO BE DETAILED, FABRICATED AND ERECTED IN ACCORDANCEWITH AISC SPECIFICATIONS, LATEST APPROVED EDITION.

3. WELDING ELECTRODE TO BE E70XX UNLESS OTHERWISE NOTED.

4. STEEL BEAMS ARE EQUALLY SPACED BETWEEN DIMENSION POINTS OR GRID LINES,UNLESS OTHERWISE NOTED.

5. ALL DETAILS ARE TYPICAL. FOR CONDITIONS NOT SPECIFICALLY SHOWN, CONTRACTORSHALL APPLY SIMILAR CONCEPT OR INTENT TO DETAIL THOSE CONDITIONS AND SUBMITFOR REVIEW AND APPROVAL.

6. TOP OF STEEL AT BEAMS FRAMING INTO SLOPING MEMBERS SHALL BE FRAMED FLUSHWITH TOP OF STEEL OF SLOPING MEMBER, UNLESS OTHERWISE NOTED.

7. BOLT HOLES FOR MACHINE BOLTS SHALL BE NO MORE THAN 1/16” OVERSIZE, UNLESSOTHERWISE NOTED. WHERE OVERSIZED HOLES ARE REQUIRED, PROVIDE 3”X3”X1

4" PLATEWASHER WELDED TO THE STRUCTURAL MEMBER.

8. CONTRACTORS SHALL SUBMIT DETAILED SHOP DRAWINGS PER SPECIFICATIONS FOR ALLSTEEL TO THE ARCHITECT FOR REVIEW PRIOR TO FABRICATION.

9. ALL STEEL EXPOSED TO WEATHER SHALL BE HOT DIP ZINC GALVANIZED UNLESSOTHERWISE NOTED.

NON-SHRINK/EXPANSIVE GROUT

1. PROVIDE MINIMUM 5000 PSI COMPRESSIVE STRENGTH OF ALL NON-SHRINK/EXPANSIVEGROUT

PLYWOOD

1. STRUCTURAL PLYWOOD SHALL BE APA RATED SHEATHING WITH EXPOSURE 1 EXTERIORGLUE AND SHALL HAVE AN APA GRADE STAMP. NO INDIVIDUAL PLYWOOD SHEET SHALL BELESS THAN 2'-0” IN ITS LEAST DIMENSION, NOR LESS THAN EIGHT(8) SQUARE FEET IN AREA.FULL PLYWOOD SHEETS (4' X 8') SHALL BE USED WHEREVER POSSIBLE.

1NOT USED5NOT USED9MATERIAL SPECIFICATIONS10MATERIAL SPECIFICATIONS11MATERIAL SPECIFICATIONS12MATERIAL SPECIFICATIONS

CONCRETE MASONRY UNIT

1. CONCRETE BLOCK SHALL BE HOLLOW, LOAD-BEARING CONCRETE MASONRY UNITSCONFORMING TO ASTM C90, GRADE N-1 MORTAR SHALL BE TYPE S. GROUT SHALLFOLLOW CONCRETE REQUIREMENTS, EXCEPT FOR SLUMP REQUIREMENT.

2. REQUIRED DESIGN STRENGTH F'M = 2500 PSI (STRUCTURAL WALL). PROVIDE CONCRETEMASONRY UNITS AND GROUT WITH COMPRESSIVE STRENGTH OF 3750 PSI. STRENGTHSHALL BE ESTABLISHED BY PRISM TEST PER 2014 OSSC.

3. USE OPEN-END UNITS, BOND BEAM UNITS AT HORIZONTAL REINFORCING. UNITS SHALL BEPLACED IN RUNNING BOND PATTERN UNLESS OTHERWISE NOTED.

4. REINFORCING BARS IN MASONRY SHALL CONFORM TO THE REQUIREMENTS OF ASTM A615,GR. 60. LAP SPLICES IN HORIZONTAL REINFORCING SHALL BE 50 DIAMETERS AND 2'-0”MINIMUM UNLESS OTHERWISE NOTED.

5. LOW LIFT CONSTRUCTION, MAXIMUM GROUT POUR HEIGHT IS 5 FEET.

6. ALL CELLS IN CONCRETE BLOCKS SHALL BE FILLED SOLID WITH GROUT UNLESSOTHERWISE NOTED.

7. CELLS SHALL BE IN VERTICAL ALIGNMENT. DOWELS SHALL BE SET TO ALIGN WITH CORESCONTAINING REINFORCING STEEL.

8. ALL ISOLATED BOLTS EMBEDDED IN MASONRY SHALL BE GROUTED SOLIDLY IN PLACEWITH NOT LESS THAN 2” OF GROUT SURROUNDING THE BOLT. BOLTS SHALL HAVE AMINIMUM EMBEDMENT OF 5” UNLESS OTHERWISE NOTED.

9. REFER TO ARCHITECTURAL DRAWINGS FOR SURFACE AND HEIGHT OF UNITS, LAYINGPATTERN AND JOINT TYPE.

10. CONTINUOUS SPECIAL INSPECTION AND TESTING IS REQUIRED FOR ALL MASONRY WORK.

11. PROVIDE SHORING AND BRACING AS REQUIRED FOR WALL CONSTRUCTION.

12. ALL REINFORCING STEEL IN MASONRY CONSTRUCTION SHALL HAVE 2” MINIMUM COVERINCLUDING THE CONCRETE BLOCK FACE SHELL.

13. TYPICAL VERTICAL WALL REINFORCEMENT SHALL BE INSTALLED EACH SIDE OF ALL WALLOPENINGS AND SHALL EXTEND THE FULL HEIGHT OF THE WALL UNLESS OTHERWISENOTED.

14. TYPICAL HORIZONTAL WALL REINFORCEMENT SHALL BE INSTALLED ABOVE AND BELOWALL OPENINGS. REINFORCEMENT SHALL EXTEND PAST OPENINGS 30” MINIMUM. IFREINFORCEMENT CANNOT EXTEND A FULL 30” PAST THE OPENING, THEN THEREINFORCING IS TO EXTEND AS FAR AS POSSIBLE AND THE REST OF THE BAR IS TO BEBENT 90 DEGREES, UP OR DOWN.

15. MECHANICAL COUPLERS WHICH DEVELOP 125% OF THE BARS YIELD STRENGTH MAY BESUBSTITUTED FOR LAP SPLICES UPON SUBMITTAL AND REVIEW BY THE ENGINEER. WHENA LAP SPLICE CANNOT BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF THE2014 OSSC, THE ENGINEER MAY SPECIFY A MECHANICAL SPLICE AT NO ADDITIONAL COSTTO THE OWNER.

16. MASONRY WALLS SHALL HAVE VERTICAL CONTROL JOINTS AT A SPACING APPROXIMATELYEQUAL TO THE WALL HEIGHT BUT NO GREATER THAN 20 FEET ON CENTER. VERTICALCONTROL JOINTS SHALL BE CONSTRUCTED AS SHOWN ON THE CONTRACT DRAWINGS.

17. CLEANOUTS SHALL BE PROVIDED AT THE BOTTOM COURSE OF EVERY GROUT POUR ATEACH VERTICAL BAR.

18. THE STANDARD WIDTH OF BOTH HORIZONTAL AND VERTICAL MORTAR JOINTS SHALL BE3/8”.

19. HIGH-LIFT GROUTING IS PERMITTED WHEN IN COMPLIANCE WITH INTERNATIONAL BUILDINGCODE.

20. PROVIDE EXPANSION JOINT @ MAXIMUM 40'-0” ON CENTER FOR ALL WALLS.

21. MORTAR SHALL CONFORM TO ASTM C270 TYPE M AND SHALL DEVELOP A MINIMUMCOMPRESSIVE STRENGTH OF 2500 PSI AT 28 DAYS. MASONRY CEMENT SHALL NOT BEUSED IN MORTAR.

© 2017 JOHNSON BRODERICK ENGINEERING. No part of this document can be reproduced without the written permission from JBE, [ 325 WEST 13TH AVENUE EUGENE OREGON, 97401. (541)338-9488 or fax (541)338-9483 ]

Proje

ct:

THE DOCUMENT AND THE DESIGNS

INCORPORATED HEREIN ARE THE

PROPERTY OF JOHNSON BRODERICK

ENGINEERING, LLC, AND IS NOT TO BE

USED, IN WHOLE OR PART, FOR ANY

OTHER PROJECT WITHOUT THE

WRITTEN AUTHORIZATION FROM THE

PRINCIPALS OF JOHNSON BRODERICK

ENGINEERING

JBE

JOHN

SON

BROD

ERIC

KEN

GINE

ERIN

GC

iv

il a

nd

S

tru

ctu

ra

l E

ng

in

ee

rs

325 W

. 13th

Ave

Euge

ne, O

r 974

01-3

402

Tel (5

41) 3

38-9

488

Fax (

541)

338-

9483

www.

JBE.

US.co

m

Project No:

Drawn By:

Sheet title:

Checked By:

Date:

Issue

dDe

scrip

tion

Mark

By

17095.01

JW

AMB

S0.1

CONS

TRUC

TION

SET

4/20/2

018WR

S

4/20/2018

MATERIALSSPECIFICATIONS

KVAL

BRO

ADCA

ST S

TATI

ON A

DDIT

IONS

AND

ALTE

RATI

ONS

4575

BLA

NTON

ROA

DEU

GENE

, OR,

9740

5

PAN DECK

1. ALL ROOF DECK TO BE VERCO PLN 18 GAGE, 24" WIDE, 3" DEEP.2. GALVANIZED DECK USING SHEET STEEL TO COMPLY WITH ASTM A653 OR A1063 , GRADE 503. WELDING MATERIALS: AWS D1.3.4. CONNECTING SIDELAPS: WELD ALL SIDELAPS.5. REINFORCE STEEL DECK OPENING PER APPROVED SHOP DRAWINGS.6. INSTALL SHEET STEEL CLOSURES AND ANGLE FLASHINGS TO CLOSE OPENING BETWEEN

DECK AND WALLS, COLUMNS AND OPENINGS.

COLD FORMED

1. ALL PRODUCTS TO BE MANUFACTURED BY THE CURRENT MEMBERS OF THE STEEL STUDMANUFACTURERS ASSOCIATION.

2. ALL GALVANIZED STUDS AND JOISTS SHALL BE FORMED FROM STEEL THATCORRESPONDS TO THE MINIMUM REQUIREMENTS OF 1996 A.I.S.I.

3. ALL STRUCTURAL MEMBERS SHALL BE DESIGNED IN ACCORDANCE WITH THE AMERICANIRON AND STEEL INSTITUTE (AISI) "SPECIFICATION FOR THE DESIGN OF COLD-FORMEDSTEEL STRUCTURAL MEMBERS" 1996 EDITION

4. PROVIDE ALL ACCESSORIES INCLUDING, BUT NOT LIMITED TO, TRACKS, CLIPS, WEBESTIFFENERS, ANCHORS, FASTENING DEVICES, RESILIENT CLIPS, AND OTHERACCESSORIES REQUIRED FOR A COMPLETE AND PROPER INSTALLATION, AND ASRECOMMENDED BY THE MANUFACTURER FOR STEEL MEMBERS USED.

5. FASTENING OF COMPONENTS SHALL BE WITH SELF-DRILLING SCREWS OR WELDING.SCREWS OR WELDS SHALL BE OF SUFFICIENT SIZE TO INSURE THE STRENGTH OF THECONNECTION. ALL WELDS OF GALVANIZED STEEL SHALL BE TOUCHED UP WITH AZINC-RICH PAINT. ALL WELDS OF CARBON SHEET STEEL SHALL BE TOUCHED UP WITHPAINT. WIRE TYING OF COMPONENTS SHALL NOT BE PERMITED

6. Fy = 50 KSI FOR ALL SECTIONS.7. STUD AND TRACK SECTIONS TO BE 600-S/T-162-54

OPEN-WEB JOISTS

1. ALL JOIST FRAMING SHALL CONFORM TO SJI LATEST EDITION

RETAINING WALLS BACKFILL & DRAINAGE:

1. FOOTING EXCAVATIONS SHOULD EXTEND BELOW ANY FILL, TOPSOIL, OR LOOSE COLLUVIAL SOIL.

2. THE FOOTING EXCAVATIONS SHOULD TERMINATE IN STIFF RESIDUAL SOIL OR WEATHERED BEDROCK.

3. THE FOOTING EXCAVATION SHOULD ALSO ACCOMMODATE A ± 6" THICK LEVELING COURSE OF COMPACTED CRUSHED ROCK BETWEEN THE BOTTOM OF THE FOOTING ANDTHE UNDERLYING FOUNDATION SOIL. ADDITIONAL CRUSHED ROCK FILL MAY BE USED TORAISE THE GRADE BENEATH THE FOOTING WHERE DEEPER EXCAVATIONS ARE REQUIRED TO REMOVE SOFT OR LOOSE SOILS OR EXISTING FILL.

4. THE BASE OF THE FOOTINGS SHOULD BE SET DEEP ENOUGH TO PROVIDE A MINIMUM SETBACK OF 5'-0" FROM THE FRONT OF THE FOOTING TO THE FACE THE SLOPING GROUND.

5. THE WALLS SHOULD BE BACKFILLED WITH WELL-GRADED, CLEAN ± 3 4" TO 112" MINUS

CRUSHED GRAVEL OR ROCK.

6. THE FILL SHOULD EXTEND A MINIMUM DISTANCE OF H BEHIND THE WALL (WHERE H IS THE WALL HEIGHT AS MEASURED FROM THE TOP OF THE WALL TO THE BASE OF THE FOOTING).

7. ALL FILL SHOULD BE PLACED IN LEVEL LIFTS NO GREATER THAN 12" AND COMPACTED TO95% RELATIVE COMPACTION BASED ON THE RESULTS OF ASTM D698.

8. LIGHT COMPACTION EQUIPMENT SHOULD BE USED TO COMPACT FILL ADJACENT TO THEWALL TO LIMIT THE RISK OF INDUCING ADDITIONAL STRESSES ON THE WALL.

9. THE EXISTING FILL GENERATED FROM ON-SITE EXCAVATION DOES NOT MEET THE REQUIREMENTS WHERE THE EXISTING ON-SITE FILL EXTENDS TO WITHIN A DISTANCE HOF THE BACK OF THE WALL, IT SHOULD BE EXCAVATED AND REPLACED WITH APPROVEDBACKFILL AS DEFINED HEREIN.

10. PROVIDE 4"Ø SLOTTED (PERFORATIONS POINTED DOWN) PVC PIPE DRAINS WRAPPED INFILTER FABRIC, SET AT THE BOTTOM OF THE GRANULAR ROCK FILL.

11. THE PIPE SHOULD BE BEDDED IN AT LEAST 4" OF DRAIN ROCK AND BACKFILLED WITH DRAIN ROCK AT LEAST 12" ABOVE THE TOP OF THE PIPE.

12. THE ENTIRE MASS OF DRAIN ROCK SHOULD BE WRAPPED IN FILTER FABRIC THAT LAPS AT LEAST 12" AT THE TOP.

13. THE FILTER FABRIC SHOULD CONSIST OF A NON-WOVEN GEOTEXTILE WITH MARV STRENGTH PROPERTIES MEETING THE REQUIREMENTS OF AN AASHTO M 288-06 CLASS 2GEOTEXTILE. THE GEOTEXTILE SHOULD HAVE A PERMITTIVITY GREATER THAN 0.5 SEC.-1AND AN AOS LESS THAN OR EQUAL TO 0.43MM.

14. DRAIN ROCK SHOULD CONSIST OF 2" MINUS, CLEAN (LESS THAN 2% PASSING THE #200 SIEVE), OPEN-GRADED GRAVEL OR ROCK.

NAIL SCHEDULENAILSIZE

NAILTYPE DIA LENGTH

6d COMMON 0.133" 2"

8d COMMON 0.131" 2 12"

10d COMMON 0.148" 3"

12d COMMON 0.148" 3 14"

16d COMMON 0.162" 3 12"

20d COMMON 0.192" 4"

\\JBE

-06\J

BE -

Proje

cts\17

095.x

x - S

ande

rs De

sign\1

7095

.01 -

4575

Blan

ton R

oad\D

rawi

ngs\C

ad\C

ONST

SET

4-20

-201

8\170

95.01

- KV

AL A

dditio

n - S

0.0 S

0.1.dw

g, 4/2

0/201

8 2:23

:11 P

M

Page 3: THE DOCUMENT AND THE DESIGNS INCORPORATED HEREIN … · 2018-04-24 · system at the construction stages indicated in the structural observation table and at completion of the structural

W10x60

HSS6x6x3/

8

HSS6x6x3/

8

HSS6x6x3/

8 W10x60

HSS6x6x3/8

HSS6

x6x3

/8

HSS6x6x3/

8

W10x60

W10x60

W10x60

A

AC

B

D

E

E

S3.03

S3.04

S3.01

S3.02

HSS6x6x3/

8

07

0707

07

06

05

0403 09

04 TYP.@ FOOTINGS

03 09

04

07 06

0504

0103

02 02

W10x60

SLOPESAD

SLOPESAD

04

05

06

05

SS

S5.15

S5.16

S5.17

S5.17

S5.17

S5.16

S5.15

SIM

SIM

SIM

S5.17

SIM

SIM

S5.14

S5.14

S5.18

S5.23

3'-11"

3'-0"

9"

9"

8'-0"

8'-0"

8'-0"

S5.13

S5.13SIM

SIM

S5.14SIM

SS

SS

SS

SS

SS

06

FOCMU

C STEELL

C STEELL

C STEELL

C STEELL

FOCMU

FOC

FOC

FOC

FOCMUFOC

FOCMU

NOTE:FOC BELOW

HSS4x4x1/

4

HSS4x4x1/

4

S5.11

TYP @ PLINTH(5 LOCATIONS)

10

11

4'-0"

4'-0"

4'-0"

4'-0"

S5.23

TYP @ EXISTINGRETAININGWALLS/STEPS

S5.217

1712

13

18

19

S5.27

S5.24 SIM

01

S5.28

S5.211

S5.214

S5.012

20

9'-8" 1'-0" 15'-7" 1'-0"

43'-0

"

5'5'

9'

5'

5'

4'

5'5'

9'

212121

S5.08

REMOVE STUD WALLMATCH TO CMU WALL

16D

S4.02

16

S5.21

14 15

43'-0"

46'-8

"

74'-11"

22'-5

"

43'-4"

NEW EXISTING

NEW EXISTING

20'-1

1"

69'-1

"

1'-0"

86'-4"

22'-4

"22

'-3"

2'-7"

1'-0"

17'-7" 22'-8"

5'-514"

16'-4"

1

A B C

2

3

4

A.8 B.5

10'-3"

9"

18'-4"

C.2

8"

1'-0"

0.5A

01HSS4x4x1/4

D

S4.01

S5.24

22

22

22

22

22

22

23

24

S2.01 FOUNDATION PLAN

3/16" = 1'-0"

GENERAL NOTES THIS SHEET:

1. SITE ELEVATION:BUILDING ELEVATION 100'-0" = SITE ELEVATION 1297.42(CONTRACTOR SHALL FIELD VERIFY ALL ELEVATIONS)

2. SEE S5.0 FOR STANDARD CONCRETE DETAILS

3. SEE S7.0 FOR STANDARD STEEL DETAILS

4. SEE S8.0 FOR STANDARD CMU DETAILS

5. SEE S3.0 FOR MOMENT FRAME ELEVATIONS

KEYED NOTES:

FF ELEV = 100'-0"

FF ELEV = 98'-6"

FF ELEV = 97'-0"

TOC = 95'-8"

TOC = 91'-8"

TOC = 87'-8"

TOC = 83'-8"

NOT USED

INDICATES 5" SLAB ON GRADE w/#4 @ 18" O.C.

FIELD VERIFY CONDITION @ SAD

6" CURB W/ #4 VERTS & (2) #4 TOP BARS SAD

CONCRETE INFILL: APPROXIMATELY 4'-9" x 22'-5" x 1'-6" DEEP

CONCRETE INFILL: APPROXIMATELY 1'-0" x 22'-0" x 1'-0" DEEP

CONCRETE INFILL: APPROXIMATELY 1'-0" x 12'-0" x 1'-0" DEEP

CONCRETE INFILL: APPROXIMATELY 6" x 3'-0" X 8" DEEP

CONCRETE INFILL: APPROXIMATELY 6" x 1'-6" X 8" DEEP

WOOD PLATFORM: APPROXIMATELY 4'-0" x 12'-0" x 1'-6" DEEP, SEE 16/S6.0

WOOD PLATFORM: APPROXIMATELY 9'-2" x 14'-0" X 1'-6" DEEP, SEE 16/S6.0

WOOD PLATFORM ASSIGNMENT DESK: APPROXIMATELY 9'-4" x 9'-8" X 1'-6" DEEP, SEE 16/S6.0

CABLE / CONDUIT TRENCH: 12" WIDE x 8" DEEP TRENCH IN CONCRETE SLAB.RUN CABLE CHASE IDENTIFIED ON FLOOR PLANS. PROVIDE REMOVABLESTEEL COVER PLATE AND 2" BEARING LEDGE ON EACH SIDE.COORDINATE WITH STRUCTURAL DRAWINGS.

WALK-OFF MAT: 1 3 4" RECESSED HEAVY TRAFFIC REESE PERFEC GRATE,FRAME 424 OR EQUAL. RECESS CONCRETE SLAB 1 3 4" AND PREPARE PERMANUFACTURER'S RECOMMENDATIONS.

INDICATES EXTENTS OF NEW FOOTING, CONTRACTOR VERIFY

INDICATES EXTENTS OF REPLACED SLAB, CONTRACTOR VERIFY

INDICATES EXTENTS OF REPLACED SLAB CONTRACTOR VERIFY

01

02

03

04

05

06

07

08

09

A

LEGEND THIS SHEET:

1. INDICATES FOOTING SEE 14/S5.0

2. S ---- S INDICATES FOOTING STEP - SEE 9/S5.0

NORTH

10

11

2

© 2017 JOHNSON BRODERICK ENGINEERING. No part of this document can be reproduced without the written permission from JBE, [ 325 WEST 13TH AVENUE EUGENE OREGON, 97401. (541)338-9488 or fax (541)338-9483 ]

Proje

ct:

THE DOCUMENT AND THE DESIGNS

INCORPORATED HEREIN ARE THE

PROPERTY OF JOHNSON BRODERICK

ENGINEERING, LLC, AND IS NOT TO BE

USED, IN WHOLE OR PART, FOR ANY

OTHER PROJECT WITHOUT THE

WRITTEN AUTHORIZATION FROM THE

PRINCIPALS OF JOHNSON BRODERICK

ENGINEERING

JBE

JOHN

SON

BROD

ERIC

KEN

GINE

ERIN

GC

iv

il an

d S

tru

ctu

ral E

ng

in

eers

325 W

. 13th

Ave

Euge

ne, O

r 974

01-3

402

Tel (5

41) 3

38-9

488

Fax (

541)

338-

9483

www.

JBE.

US.co

m

Project No:

Drawn By:

Sheet title:

Checked By:

Date:

Issue

dDe

scrip

tion

Mark

By

KVAL

ADD

ITIO

NS &

ALT

ERAT

IONS

4575

BLA

NTON

ROA

DEU

GENE

, OR

9740

5

FOUNDATIONPLAN

4/20/2018

WRS

4/20/2

018CO

NSTR

UCTI

ON S

ET

S2.0

AMB

JW

17095.01

3

12

13

14

15

16

17

18

19

20

21

22

23

24

\\JBE

-06\J

BE -

Proje

cts\17

095.x

x - S

ande

rs De

sign\1

7095

.01 -

4575

Blan

ton R

oad\D

rawi

ngs\C

ad\C

ONST

SET

4-20

-201

8\170

95.01

- KV

AL A

dditio

n - S

2 Ser

ies 2.

1.dwg

, 4/23

/2018

9:05

:31 A

M

Page 4: THE DOCUMENT AND THE DESIGNS INCORPORATED HEREIN … · 2018-04-24 · system at the construction stages indicated in the structural observation table and at completion of the structural

W16x26 W18x50

W16x26

W18x50 W16x26

W18

x50

W18

x50

W18

x50

HSS6x

HSS6x

HSS6x

W10x

HSS6xHSS6x

W10x

W10x

W10x

HSS6x

W16x26

S3.03

S3.04

S3.01

S3.02

W18

x50

W18

x50

W18

x50

W18

x50

S4.02

S4.01

01

TOM117.00'

HSS6x

W16x26

FOM

FOM

05

02

01

J1

J2

J7

J8

J9

J10

J10

J3

J4

J5

J6

RTU-2

S8.010

S8.013

S8.014

TOM117.00'

TOM 119.67'

TOM 119.67'

W8x24

S7.13

S7.16

S7.15

S7.18 S7.1

8

S7.19

S7.15

SIM

S7.110

S7.111

S7.14

(5 E

Q SP

ACES

)(6

EQ

SPAC

ES)

(6 E

Q SP

ACES

)

RTU-1

K-108-4FAUCETANTIQUEBRASS

K-108-4FAUCETANTIQUEBRASS

43'-0"46

'-8"

74'-11"

22'-5

"43'-4"

NEW EXISTING

NEW EXISTING

20'-1

1"

69'-1

"

1'-0"

86'-4"

22'-4

"22

'-3"

2'-7"

1'-0"

17'-7" 22'-8"

5'-514"

16'-4"

1

A B C

2

3

4

CORRIDOR 1

CONTROL 2

ELEC CHANGE

CORRIDOR 2

A.8 B.5

10'-3"

10"

18'-4"

C.2

1'-2"

1'-0"

0.5A

TOS = 111.56'C STEELL

TOS = 112.50'C STEEL

C STEEL

TOS = 111.56'C STEEL

W14

x22

W10x

W10

FOM

FOM

FOM

SLOPE: 34" : 12"

SLOPE: 12" : 12"

SLOPE: 14" : 12"S8.011

04

04

RIDGE

S5.217

S7.24

03 03 03

02 02

J11

J12

03 03 03

L

L

L

16K

06

S5.012

S8.015

07

07

08 09

10

12

11

© 2017 JOHNSON BRODERICK ENGINEERING. No part of this document can be reproduced without the written permission from JBE, [ 325 WEST 13TH AVENUE EUGENE OREGON, 97401. (541)338-9488 or fax (541)338-9483 ]

Proje

ct:

THE DOCUMENT AND THE DESIGNS

INCORPORATED HEREIN ARE THE

PROPERTY OF JOHNSON BRODERICK

ENGINEERING, LLC, AND IS NOT TO BE

USED, IN WHOLE OR PART, FOR ANY

OTHER PROJECT WITHOUT THE

WRITTEN AUTHORIZATION FROM THE

PRINCIPALS OF JOHNSON BRODERICK

ENGINEERING

JBE

JOHN

SON

BROD

ERIC

KEN

GINE

ERIN

GC

iv

il an

d S

tru

ctu

ral E

ng

in

eers

325 W

. 13th

Ave

Euge

ne, O

r 974

01-3

402

Tel (5

41) 3

38-9

488

Fax (

541)

338-

9483

www.

JBE.

US.co

m

Project No:

Drawn By:

Sheet title:

Checked By:

Date:

Issue

dDe

scrip

tion

Mark

By

17095.01

JW

AMB

S2.1

CONS

TRUC

TION

SET

4/20/2

018JW

4/20/2018

ROOFFRAMING

PLAN

KVAL

ADD

ITIO

NS &

ALT

ERAT

IONS

4575

BLA

NTON

ROA

DEU

GENE

, OR

9740

5

S2.11 ROOF FRAMING PLAN

3/16" = 1'-0"

KEYED NOTES THIS SHEET:

18 GAGE PLN3 W/ SIDE LAP @ 24" OC WELD EA FLUTE @ SUPPORTS

BRIDGING @ 13 POINTS W/ END BRACE

BRIDGING @ 14 POINTS W/ END BRACE

COORDINATE DIAPHRAGM OPERATION w/ MFG

EYBROW PER

COORDINATE UNIT SUPPORT & DECK PENETRATION W/ MECHANICALSUBMIT W/ SHOP DRAWINGS

ROOF MOUNTED DUCTWORK: NEW, INSULATED. PENETRATE CMU WALL.PROVIDE LINTEL FOR OPENINGS AND WEATHER PROOF SLEEVE.COORDINATE WITH MECHANICAL, STRUCTURAL DRAWINGS, AND DETAILS.REFERENCE DETAIL 5/S8.0 FOR REINFORCEMENT AT HEADERS

WALK PADS: PVC WALK PAD, 72 MIL. BASIS OF DESIGN JOHNSMANVILLE LM PVC WALKPAD. DIMENSIONS SHOWN ARE APPROXIMATE.COORDINATE LAYOUT WITH FINAL RTU AND LADDER LOCATIONS

ROOF LADDER: FIXED STEEL, PAINTED. ATTACH TO EXISTING CMUWALL. COORDINATE WITH STRUCTURAL DRAWINGS

DIMENSION 6"

DIMENSION 3 12"

DIMENSION 3 12"

01

02

03

04

GENERAL NOTES THIS SHEET:

1. SEE S0.0 FOR GENERAL NOTES, REQ'D TESTING, S.I. SUBMITTALS,OBSERVATION, AND LEGEND.

2. SEE S7.5 FOR COLD FORMED STEEL DETAILS.

LEGEND THIS SHEET:

NORTH

EQUIPMENT DESIGN WEIGHT

1763 lbs.HVAC UNIT - RTU-2

HVAC UNIT - RTU-1 2198 lbs.

INDICATES MOMENT CONNECTION SEE S3.0.

INDICATES DRAG CONNECTION SEE 5/S7.0

INDICATES HSS 4x4x1/4

INDICATES APPROXIMATE LOCATION OF MECHANICAL UNIT REFERTO MECHANICAL DRAWINGS FOR SIZES & WEIGHTS.

INDICATES LOCATION OF AXIAL LOAD SEE TABLE

INDICATES TRUSS BRIDGING

INDICATES HSS

INDICATES WIDE FLANGE

X

05 S7.22

06

07

08

09

10

11

12

\\JBE

-06\J

BE -

Proje

cts\17

095.x

x - S

ande

rs De

sign\1

7095

.01 -

4575

Blan

ton R

oad\D

rawi

ngs\C

ad\C

ONST

SET

4-20

-201

8\170

95.01

- KV

AL A

dditio

n - S

2 Ser

ies.dw

g, 4/2

3/201

8 8:28

:48 A

M

Page 5: THE DOCUMENT AND THE DESIGNS INCORPORATED HEREIN … · 2018-04-24 · system at the construction stages indicated in the structural observation table and at completion of the structural

W10

x

W18x

W10

x

121/4 C STEELL

C STEELL

0203

0504

2 1

PLINTH BEYONDPLINTH BEYOND

SLAB ON GRADEELEVATION: 97.00'

TOSELEVATION: 111.68'

TOSELEVATION: 112.14'

W18x

120

W16x

0203

05 04C STEELLC STEELL

A A.8

PLINTH BEYONDPLINTH BEYOND

SLAB ON GRADEELEVATION: 97.00'

TOSELEVATION: 111.72'

121/2

W18x

C STEELL

C STEELL

0203

0504

3 4

SLAB ON GRADEELEVATION: 97.00'

TOSELEVATION: 111.82'

TOSELEVATION: 112.76' W18x

120

W18x W16x

C STEELLC STEELL

03 02

05 04

C B.5

SLAB ON GRADEELEVATION: 97.00'

TOSELEVATION: 112.49'

S3.01 MOMENT FRAME (GRID A)

1/4" = 1'-0"

© 2017 JOHNSON BRODERICK ENGINEERING. No part of this document can be reproduced without the written permission from JBE, [ 325 WEST 13TH AVENUE EUGENE OREGON, 97401. (541)338-9488 or fax (541)338-9483 ]

Proje

ct:

THE DOCUMENT AND THE DESIGNS

INCORPORATED HEREIN ARE THE

PROPERTY OF JOHNSON BRODERICK

ENGINEERING, LLC, AND IS NOT TO BE

USED, IN WHOLE OR PART, FOR ANY

OTHER PROJECT WITHOUT THE

WRITTEN AUTHORIZATION FROM THE

PRINCIPALS OF JOHNSON BRODERICK

ENGINEERING

JBE

JOHN

SON

BROD

ERIC

KEN

GINE

ERIN

GC

iv

il an

d S

tru

ctu

ral E

ng

in

eers

325 W

. 13th

Ave

Euge

ne, O

r 974

01-3

402

Tel (5

41) 3

38-9

488

Fax (

541)

338-

9483

www.

JBE.

US.co

m

Project No:

Drawn By:

Sheet title:

Checked By:

Date:

Date

Revis

ions

Symb

olBy

17095.01

JW

AMB

S3.0

CONS

TRUC

TION

SET

4/20/2

018WR

S

4/20/2018

MOMENTFRAME

ELEVATIONS

KVAL

ADD

ITIO

NS &

ALT

ERAT

IONS

4575

BLA

NTON

ROA

DEU

GENE

, OR

9740

5

S3.02 MOMENT FRAME (GRID 1)

1/4" = 1'-0"

S3.03 MOMENT FRAME (GRID C)

1/4" = 1'-0"

S3.04 MOMENT FRAME (GRID 4)

1/4" = 1'-0"

KEYED NOTES THIS DETAIL:

SEE S/2.0 AND S/2.1 FOR MEMBER SIZES NOT NOTED

SEE 1/S7.1 FOR BASE DETAILS

SEE 1/S7.1 FOR BASE DETAILS

SEE 2/S7.1 FOR CONNECTION DETAILS

SEE 2/S7.1 FOR CONNECTION DETAILS

01

02

03

04

05

KEYED NOTES THIS DETAIL:

SEE S/2.0 AND S/2.1 FOR MEMBER SIZES NOT NOTED

SEE 1/S7.1 FOR BASE DETAILS

SEE 1/S7.1 FOR BASE DETAILS

SEE 2/S7.1 FOR CONNECTION DETAILS

SEE 2/S7.1 FOR CONNECTION DETAILS

01

02

03

04

05

KEYED NOTES THIS DETAIL:

SEE S/2.0 AND S/2.1 FOR MEMBER SIZES NOT NOTED

SEE 1/S7.1 FOR BASE DETAILS

SEE 1/S7.1 FOR BASE DETAILS

SEE 2/S7.1 FOR CONNECTION DETAILS

SEE 2/S7.1 FOR CONNECTION DETAILS

01

02

03

04

05

KEYED NOTES THIS DETAIL:

SEE S/2.0 AND S/2.1 FOR MEMBER SIZES NOT NOTED

SEE 1/S7.1 FOR BASE DETAILS

SEE 1/S7.1 FOR BASE DETAILS

SEE 2/S7.1 FOR CONNECTION DETAILS

SEE 2/S7.1 FOR CONNECTION DETAILS

01

02

03

04

05

\\JBE

-06\J

BE -

Proje

cts\17

095.x

x - S

ande

rs De

sign\1

7095

.01 -

4575

Blan

ton R

oad\D

rawi

ngs\C

ad\C

ONST

SET

4-20

-201

8\170

95.01

- KV

AL A

dditio

n - S

3 SER

IES.

dwg,

4/20/2

018 2

:34:19

PM

Page 6: THE DOCUMENT AND THE DESIGNS INCORPORATED HEREIN … · 2018-04-24 · system at the construction stages indicated in the structural observation table and at completion of the structural

SLAB ON GRADEELEVATION: 97.00'

C

S8.012

S8.010

S8.013

S7.28

S8.07

S7.211

BA.8A0.5A

WALL ASSEMBLY, SAD TYP

ROOF ASSEMBLY, SAD

STUDIO GRID, SAD

CEILING GRID, SAD

NOTE: CONTRACTOR TO VERIFYEXISTING FOOTING, IN RELATIONSHIPTO NEW FOOTING

NOTE:REFERENCE THE FOLLOWINGDRAWINGS FOR THE EXISTING BUILDING,FOUNDATION AND BUILDING INFORMATION.

A1 - SITE AND ROOF PLANA3 - FOUNDATION & FLOOR PLANA4 - STRUCTURAL SECTIONSA5 - INT. ELEVATIONSA6 - MISC. & STRUCTURAL DETAILSA1 - FLOOR PLAN - FOUNDATION (1956)A1 - FOUNDATION (1964)A1 - PLANS (1984)A2 - FLOOR PLANS (1984)003 - FLOOR PLAN (1988)006 - FOOTING (1988)007 - SECTION DETAILS (1988)008 - SECTION DETAILS (1988)

SLAB ON GRADEELEVATION: 97.00'

S7.13

S5.17

S7.16

S7.110

S5.21

S5.219

A B C

S7.22

SLAB ON GRADEELEVATION: 98.5'

© 2017 JOHNSON BRODERICK ENGINEERING. No part of this document can be reproduced without the written permission from JBE, [ 325 WEST 13TH AVENUE EUGENE OREGON, 97401. (541)338-9488 or fax (541)338-9483 ]

Proje

ct:

THE DOCUMENT AND THE DESIGNS

INCORPORATED HEREIN ARE THE

PROPERTY OF JOHNSON BRODERICK

ENGINEERING, LLC, AND IS NOT TO BE

USED, IN WHOLE OR PART, FOR ANY

OTHER PROJECT WITHOUT THE

WRITTEN AUTHORIZATION FROM THE

PRINCIPALS OF JOHNSON BRODERICK

ENGINEERING

JBE

JOHN

SON

BROD

ERIC

KEN

GINE

ERIN

GC

iv

il an

d S

tru

ctu

ral E

ng

in

eers

325 W

. 13th

Ave

Euge

ne, O

r 974

01-3

402

Tel (5

41) 3

38-9

488

Fax (

541)

338-

9483

www.

JBE.

US.co

m

Project No:

Drawn By:

Sheet title:

Checked By:

Date:

Issue

dDe

scrip

tion

Mark

By

17095.01

JW

AMB

S4.0

CONS

TRUC

TION

SET

4/20/2

018WR

S

4/20/2018

BUILDINGSECTIONS

KVAL

ADD

ITIO

NS &

ALT

ERAT

IONS

4575

BLA

NTON

ROA

DEU

GENE

, OR

9740

5

S4.01 BUILDING SECTION

1/4" = 1'-0"

S4.02 BUILDING SECTION

1/4" = 1'-0"

2

\\JBE

-06\J

BE -

Proje

cts\17

095.x

x - S

ande

rs De

sign\1

7095

.01 -

4575

Blan

ton R

oad\D

rawi

ngs\C

ad\C

ONST

SET

4-20

-201

8\170

95.01

- KV

AL A

dditio

n - S

4 Ser

ies.dw

g, 4/2

0/201

8 2:36

:57 P

M

Page 7: THE DOCUMENT AND THE DESIGNS INCORPORATED HEREIN … · 2018-04-24 · system at the construction stages indicated in the structural observation table and at completion of the structural

12d

90°D

d

45°

45°

180°D

D D

4d OR21

2" MIN

D = 6d FOR #3 THRU #8D = 8d FOR #9 THRU #11D = 10d FOR #14 & #18

ALL REINFORCING EXCEPT COLUMN TIES AND BEAM STIRRUPS

d

D

D

180°6d O

R3"

MIN

STIRRUP

D

D

180°

6d OR3" MIN

d

12d

D

D

d

90°

STIRRUP OR TIED = 4d FOR #3 THRU #5D = 6d FOR #6 THRU #8

6d O

R3"

MIN

D D90° 135°

6d OR

3" MIN

d

6d O

R3"

MIN

90° 180°6d OR3" MIN

BEAM OR COLUMN CROSSTIESBEAM STIRRUPS AND COLUMN TIES

D D

NOTE:TIES AND CROSSTIES FOR SHEAR WALL BOUNDARY ELEMENTSSHALL BE DETAILED AS COLUMN TIES/CROSSTIES

BARSIZE

MISCBARS

TOPBARS

HOOKEDBARS

Ld SPLICE Ld SPLICE Ldh f'c = 3000psi

#3 17 23 22 29 9#4 22 29 29 38 11#5 28 37 36 47 14#6 33 43 43 56 17#7 48 63 63 82 20#8 55 72 72 94 22#9 62 81 81 106 25

#10 70 91 91 119 28#11 78 102 101 132 31

f'c = 4000psi#3 15 20 16 25 8#4 19 25 25 33 10#5 24 32 31 41 12#6 29 38 37 49 15#7 42 55 54 71 17#8 48 63 62 81 19#9 54 71 70 91 22

#10 61 80 79 103 25#11 67 88 87 114 27

NOTES:1. VALUES FOR UNCOATED REINFORCING

AND NORMAL WEIGHT CONCRETE WITH CLEAR SPACING > db, CLEAR COVER > db AND MINIMUM STIRRUPS OR TIES THROUGHTOUT Ld OR CLEAR SPACING > 2db AND CLEAR COVER > db.

2. DEVELOP ALL REINFORCING IN STRUCTURAL SLABS WITH MINIMUM DEVELOPMENT LENGTH Ld.

3. Ldh = DEVELOPMENT LENGTH OF BAR WITH MINIMUM DEVELOPMENT LENGTH Ld.

4. TOP BAR = HORIZONTAL BAR WITH MORE THAN 12" OF FRESH CONCRETE BELOW (EXCLUDING WALL HORIZONTAL REINFORCING) OR AS NOTED ON DOCUMENTS AS "TOP BAR"

5. ALL TABULATED VALUES ARE IN INCHES.

PLAN SECTION AT SINGLE CURTAIN REINFORCEMENT

INTERSECTION

CORNER INTERSECTION

PLAN SECTION AT DOUBLE CURTAIN REINFORCEMENT

CORNER

SPLICELENGTH

TYP

34" CHAMFER @WALLS NOT IN

CONTACT W/ SOIL

SPLIC

ELE

NGTH

TYP

CORNER REINFTO MATCHHORIZ REINF

ALT EA SIDESTD HOOK

CORNER REINF TOMATCH CROSS ALLHORIZ REINF

CROSS WALL

NOTES:1. SPLICE LENGTHS PER LAP SPLICE AND DEVELOPMENT LENGTH SCHEDULE2. WALL REINFORCING PER PLAN OR ELEVATIONS, SECTION AND DETAILS3. AT FOOTINGS AND STEMWALLS, CORNER REINFORCING TO MATCHFOOTINGS AND STEMWALL HORIZONTAL REINFORCING.

34" CHAMFER @WALLS NOT IN

CONTACT W/ SOIL

STD HOOK

SPLIC

ELE

NGTH

TYP

SPLIC

ELE

NGTH

TYP

CORNER REINFTO MATCHHORIZ REINF

CORNER REINF TOMATCH CROSSWALL HORIZ REINF

CROSS WALL

CONTROL JOINT

CONSTRUCTION JOINT

TO SLABPER PLAN

TO SLABPER PLAN

58"Øx24" SMOOTH BAR

@ 24" OC, GREASE ONE SIDEIN DOWEL INSERT

REINF PER PLAN

SUBGRADE PREPARATIONPER GEOTECH REPORT COMPACTED STRUCT FILL

OR COMPETENT NATIVE SOILPER GEOTECH REPORT

VAPOR BARRIER WHEREREQ'D

t/4 SAWCUT DEPTH ORt/4 PREMOLDED JOINT (11

2" MIN)REINF PER PLAN

SUBGRADE PREPARATIONPER GEOTECH REPORT

COMPACTED STRUCT FILLOR COMPETENT NATIVE SOILPER GEOTECH REPORT

VAPOR BARRIERWHERE REQ'D

NOTES:1. USE "EARLY ENTRY DRY-CUT SAW" AS SOON AS POSSIBLE WITHOUT CAUSING RAVELINGOF CONCRETE EDGES. SAWCUT ALONG SHORT DIRECTION OF POUR FIRST.2. ALIGN A CONSTRUCTION OR CONTROL JOINT WITH RE-ENTRANT SLAB CORNER, EW, TYP3. PROVIDE CONSTRUCTION/CONTROL JOINT TO ENCLOSE APPROXIMATE SQUARE AREAS 225SQUARE FEET MAXIMUM, W/ A MAXIMUM PANEL ASPECT RATIO OF 1.3 TO 1.04. CONTRACTOR TO SUBMIT CONSTRUCTION/CONTROL JOINT PLAN TO ENGINEER OF RECORDFOR REVIEW/APPROVAL

PER

ARCH

(2'-0

" MAX

)

PER ARCH4'-0" MAX)

OPENING

2"CLRTYP

2'-6"MINTYP

PROVIDE REINF ON ALL SIDESEQ TO ONE-HALF THE AREASOF SLAB REINF CUT BY OPNG((2) #4 CTRD ALL SIDES MIN)

(2) #4x48" DIAG TYP@ EA CORNER CTRD

NOTES:1. ALL OPENINGS W/ A DIM OF 24" OR GREATER SHALL BE TRIMMED WITH REINFORCING2. REINFORCING IS IN ADDITION TO ANY REINFORCING INDICATED ON PLANS3. HOOK REINFORCING @ SLAB EDGE AS REQUIRED

MATCH FOOTINGREINFORCEMENT SIZE ANDSPACING TYP T TY

P

LTYP

H TYP

db = BAR DIAMETERH = L/2 MAXL = 4'-0" MINT = FOOTING THICKNESS

TRANSVERSEBAR @ HOOK TYP

NOTE:1. REINFORCEMENT TO MATCH SIZE AND SPACING OF FOOTING BOTTOM BARS (TYP)2. WHERE MASONRY OCCURS "H" SHALL MATCH MASONRY MODULE

18"MIN

18"MIN

(2) T TYP

TO FTGPER PLAN

FTG

DEPT

HPE

R PL

AN3'-

0" M

AX

6" CLR

MIN

1'-6" MIN

EQ EQ℄ PIPE

31 2" CL

RMI

N4"

DO NOT PASS PIPESTHRU THIS PORTION

OF FTG

ELEVATION

PIPE SLEEVEAS REQ'D TYP

CONC STEMWALLPER PLAN

PIPE TYP

CONC FTGPER PLAN

PLACE CONC FILLBEFORE FTG POUR(SAME WIDTH AS FTG)

S5.05a

NOTES:1. PRIOR TO CONSTRUCTION, STRUCTURAL ENGINEER OF RECORD SHALL REVIEWPIPES/SLEEVES GREATER THAN 8" DIAMETER AND SPACED CLOSER THAN 3" APART2. ALUMINUM MATERIALS SHALL NOT BE EMBEDDED IN CONCRETE

TO FTGPER PLAN

FOOT

ING

DEPT

HBE

YOND

PER

PLA

N

PER PLAN

FIN GRADEPER ARCH\

CIVIL

1'-6" MIN

12

SLOPE CUT &BACKFILL AS REQ'DPER GEOTECHREPORT

ELEVATIONNO EXCAVATIONBELOW THIS LINEWITHIN 10' OFFOOTING

10'-0" TRENCHEXCAVATION

1'-6"MIN

TRENCHEXCAVATION

CONC FTGPER PLAN

NO EXCAVATIONBELOW THIS LINEWITHIN 10' OFFOOTING

SLOPE CUT &BACKFILL AS REQ'DPER GEOTECHREPORT

TO SLABPER PLAN

2" CLR

3" CLR

4"MIN

PIPE OR CONDUITSOG PER PLAN

NOTE:1. ALUMINUM MATERIAL SHALL NOT BE EMBEDDED IN CONCRETE

6"TYP

BASE PLATE & TYPEPER PLAN

CONTROL JOINT ORCONST JOINT

FILL AFTER MINIMUM 7-DAYSSLAB CURE

8"5"

1'-0"

5" 5"

REINFORCING PER PLAN

SLAB PER PLAN

#5@ 16" OC

12" 12"

(4) #5 CONTINUOUS

11

P 12" X 1'-4" CONTINUOUSL

2" 2"

1'-4"

FOOTING SCHEDULE

MARK SIZE L x W x TREINFORCING

REMARKSLONGITUDINAL TRANSVERSE

A 5'-0" x 5'-0" x 1'-0" TOP --- --- BASE PLATE PERBOTTOM (6) #5 (6) #5

B 6'-0" x 6'-0" x 1'-0" TOP --- --- BASE PLATE PERBOTTOM (7) #5 (7) #5

C 7'-0" x 7'-0" x 1'-6" TOP --- --- BASE PLATE PERBOTTOM (8) #5 (8) #5

D 4'-0" x 4'-0" x 1-0" TOP --- --- BASE PLATE PERBOTTOM (5) #5 (5) #5

E CONT. x 4'-0" x 3'-0" TOP (6) #6 #4 @ 6" SEE 15/S5.0BOTTOM (6) #6 #4 @ 6"

S7.11

S7.11

S7.11

S7.11

TO SOGELEV. 0'-0"

2" GROUT MAX

GRIDSEE 3/S7.0 FORINFORMATION NOT NOTED

FOOTING PER PLAN

1'-4"

1'-0"

CL

TO SOGELEV. 0'-0"

3'-0"

4'-0"

W10x

(6) #6 CONT.(TYP @ TOP AND BOTTOM)

(3) #4 HOOPS @ 2" OC

#4 HOOPS @ 6" OC

#4 TRANSVERSE @ 6" OC

#4 (TYP OF (4) @ BOLTS)

6" M

IN

UNDISTURBEDNATIVE SOIL

4" PERFDRAINAGEPIPE TODAYLIGHT

FREE DRAININGROCK FILL

FILTER CLOTH -WRAP AROUNDBACKFILL

1

CLEAN DRAIN STONE

1

6" MIN CORNER

4" WEEP HOLE@8'-0" OC

DRAIN BOARD

SLAB & PAVING OR 1' PLANTING MEDIMUM

EXISTING FOUNDATION

REMOVE EXISTINGSTUD WALL AFTERIT IS PROPERLY SHORED

SACRIFICIALSCREW SHORE(SIZE AND LOCATIONAS REQUIRED)

CMU WALLSTUD WALL

NEW PLATEEXISTINGFOUNDATION

INFILL EXISTING TRENCHWITH CONCRETE

S5.01 STANDARD HOOKS & BENDS

3/4" = 1'-0"

S5.02 TYP LAP SPLICE AND DEVELOPMENT LENGTH

NOT TO SCALE

S5.05 PIPE OR CONDUIT EMBEDDED IN SLAB ON GRADE

1'=1'-0"

S5.06 PLAN - TYP SLAB OPENING REINFORCING @ SLAB ON GRADE

NTS

S5.07 PLAN - TYP CONTROL JOINT @ COLUMNS

NTS

S5.04 TYP SLAB ON GRADE JOINT DETAILS W/ REINFORCING

3/4" = 1'-0"S5.08 DUCT IN SLAB SAD

1" = 1'-0"

S5.09 TYPICAL STEPPED FOOTING

NOT TO SCALE

S5.03 PLAN SECTION @ SINGLE & DOUBLE CORNER REINFORCING (FTGS SIM)

3/4" = 1'-0"

S5.011 TYP EXCAVATION ADJACENT TO FOOTING

S5.010 ELEVATION OF TYP PIPE & TRENCH LOCATIONS

NOT TO SCALE

S5.012 WALL SHORING DETAIL

S5.016 RETAINING WALL BACKFILL

S5.015 MOMENT FRAME FOUNDATION

3/4" = 1'-0"S5.018 NOT USED

© 2017 JOHNSON BRODERICK ENGINEERING. No part of this document can be reproduced without the written permission from JBE, [ 325 WEST 13TH AVENUE EUGENE OREGON, 97401. (541)338-9488 or fax (541)338-9483 ]

Proje

ct:

THE DOCUMENT AND THE DESIGNS

INCORPORATED HEREIN ARE THE

PROPERTY OF JOHNSON BRODERICK

ENGINEERING, LLC, AND IS NOT TO BE

USED, IN WHOLE OR PART, FOR ANY

OTHER PROJECT WITHOUT THE

WRITTEN AUTHORIZATION FROM THE

PRINCIPALS OF JOHNSON BRODERICK

ENGINEERING

JBE

JOHN

SON

BROD

ERIC

KEN

GINE

ERIN

GC

iv

il an

d S

tru

ctu

ral E

ng

in

eers

325 W

. 13th

Ave

Euge

ne, O

r 974

01-3

402

Tel (5

41) 3

38-9

488

Fax (

541)

338-

9483

www.

JBE.

US.co

m

Project No:

Drawn By:

Sheet title:

Checked By:

Date:

Date

Revis

ions

Symb

olBy

17095.01

JW

AMB

S5.0

CONS

TRUC

TION

SET

4/20/2

018WR

S

4/20/2018

CONCRETEDETAILS

KVAL

ADD

ITIO

NS &

ALT

ERAT

IONS

4575

BLA

NTON

ROA

DEU

GENE

, OR

9740

5

S5.014 FOOTING SCHEDULE

S5.013 FOOTING

\\JBE

-06\J

BE -

Proje

cts\17

095.x

x - S

ande

rs De

sign\1

7095

.01 -

4575

Blan

ton R

oad\D

rawi

ngs\C

ad\C

ONST

SET

4-20

-201

8\170

95.01

- KV

AL A

dditio

n - S

5 SER

IES.

dwg,

4/20/2

018 2

:45:00

PM

AutoCAD SHX Text
2
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
1
Page 8: THE DOCUMENT AND THE DESIGNS INCORPORATED HEREIN … · 2018-04-24 · system at the construction stages indicated in the structural observation table and at completion of the structural

91'-8"

1'-0"

4'-0"

6'-0"

3'-6" 1'-0" 1'-6"

1'-4"

5'-4"

6'-4"

97'-0"

#5 @ 12"EW

#5 @ 8" OC ALT HOOKS

#5 @ 12"

#5 @ 12" OC

#5 @ 12"

3'-0"

#5 @ 12"

#5 @ 12"

#5 @ 12"

1'-0"

(2) #5

NOTE:WHERE MASONRY OCCURS SEE 9/S5.1

11" OR 12"

1'-0"

1'-4"

2'-0"

1

#5 @ 12"

#5 @ 16" OC ALT HOOKS

#5 @ 12"

3

#5 @ 12"

2'-0"

1'-0"

NOTE:2'-0" MAX HEIGHT CURB@ THIS LOCATION(GRIDLINE 3 ONLY)

1'-6"

1'-4"

4'-0"

1'-0"

#5 @ 12"

#5 @ 8" OC ALT HOOKS

#5 @ 12"

#5 @ 12" OC ALT HOOKS

#5 @ 16"

1'-0"

1'-4"

4'-0"

1'-0"

WHERE OCCURS

#5 @ 8" OC ALT HOOKS

#5 @ 12"

#5 @ 12"

#5 @ 16" OC ALT HOOKS

#5 @ 16" #5 @ 16"

87'-8"

1'-6"

8'-0"

9'-3"

1'-0"

5'-3" 1'-0" 3'-0"

1'-4"

9'-4"

10'-1

0"

97'-0"

#6 @ 12" OC ALT HOOKS

#5 @ 12" OC

#5 @ 12"

#5 @ 16" OC ALT HOOKS

#5 @ 12" #5 @ 12"

11 2" CL

R TY

PAL

L SID

ES

5'-0"

(2) #5#5 @ 12" OC

NOTE:WHERE MASONRY OCCURS SEE 9/S5.1

83'-8"

1'-6"

12'-0

"

11'-6"

1'-0"

7'-6" 1'-0" 3'-0"

1'-4"

13'-4

"

14'-1

0"

97'-0"

#5 @ 16" OC ALT HOOKS

#5 @ 12"

11 2" CL

R TY

PAL

L SID

ES

#6 @6" OC ALT HOOKS

7'-0"

#3 @ 12" OCALONG LENGTH

OF GRADE BEAM(OCCURS @ MOMENT FRAMES)

GRADE BEAMWHERE OCCURS

(2) #5

#5 @ 12" #5 @ 12"

#6 @ 12" OC#6 @ 12" OC

#6 CONT

NOTE:WHERE MASONRY OCCURS SEE 9/S5.1

1'-0"

1'-0"

2'-0"

2'-0"

#6 VERTICALS (TYP OF 8)

#4 @ 6" OCW/ (3) @ 2" OC @ TOP OF PLINTH

RETAINING WALL(STEEL NOT SHOWNFOR CLARITY)

S5.11

1'-0"

#5 @ 12"

#5 @ 16" OC ALT HOOKS

#5 @ 16"

#6 @ 16"

#5 @ 16" OCEA FACE

4'-0" LAP

3'-0" LAP

COLUMN BASE ANDANCHORS PER PLAN

(MOMENT FRAMESHOWN, HSS

COLUMN SIMILAR)

2"2"

2"6"

TO PLINTHELEV. 97'-0"

2"

(3) #4 HOOPS @ 2" OC

#4 HOOPS @ 6" OC

2" GROUT MAX

S5.11 PLINTH ELEVATION

1" = 1'-0"S5.15 FOUNDATION @ GRIDS 1 & 0.5A

3/4" = 1'-0"

S5.18 GRADE BEAM @ GRID 2

3/4" = 1'-0"

S5.13 FOUNDATION @ GRIDS 1, 4 & C

3/4" = 1'-0"

© 2017 JOHNSON BRODERICK ENGINEERING. No part of this document can be reproduced without the written permission from JBE, [ 325 WEST 13TH AVENUE EUGENE OREGON, 97401. (541)338-9488 or fax (541)338-9483 ]

Proje

ct:

THE DOCUMENT AND THE DESIGNS

INCORPORATED HEREIN ARE THE

PROPERTY OF JOHNSON BRODERICK

ENGINEERING, LLC, AND IS NOT TO BE

USED, IN WHOLE OR PART, FOR ANY

OTHER PROJECT WITHOUT THE

WRITTEN AUTHORIZATION FROM THE

PRINCIPALS OF JOHNSON BRODERICK

ENGINEERING

JBE

JOHN

SON

BROD

ERIC

KEN

GINE

ERIN

GC

iv

il an

d S

tru

ctu

ral E

ng

in

eers

325 W

. 13th

Ave

Euge

ne, O

r 974

01-3

402

Tel (5

41) 3

38-9

488

Fax (

541)

338-

9483

www.

JBE.

US.co

m

Project No:

Drawn By:

Sheet title:

Checked By:

Date:

Date

Revis

ions

Symb

olBy

17095.01

JW

AMB

S5.1

CONS

TRUC

TION

SET

4/20/2

018WR

S

4/20/2018

CONCRETEDETAILS

KVAL

ADD

ITIO

NS &

ALT

ERAT

IONS

4575

BLA

NTON

ROA

DEU

GENE

, OR

9740

5

S5.16 FOUNDATION @ GRID 1 & 0.5A

3/4" = 1'-0"

S5.17 FOUNDATION @ GRIDS 0.5A, A & 1

3/4" = 1'-0"

S5.14 FOUNDATION @ GRID B

3/4" = 1'-0"S5.19 MASONRY @ TOP OF WALL

1/2" = 1'-0"

S5.11 PLINTH PLAN

3/4" = 1'-0"

\\JBE

-06\J

BE -

Proje

cts\17

095.x

x - S

ande

rs De

sign\1

7095

.01 -

4575

Blan

ton R

oad\D

rawi

ngs\C

ad\C

ONST

SET

4-20

-201

8\170

95.01

- KV

AL A

dditio

n - S

5 SER

IES.

dwg,

4/20/2

018 2

:46:09

PM

Page 9: THE DOCUMENT AND THE DESIGNS INCORPORATED HEREIN … · 2018-04-24 · system at the construction stages indicated in the structural observation table and at completion of the structural

1'-6" 3'-0" 2'-0" 1'-9" 1'-6"

1'-0"

TYP

#5 @ 12"

#5 @ 16" OC ALT HOOKS

#5 @ 12" VARIES

1'-0" 1'-0" 1'-3" 1'-3"

4'-0" 4'-0"

10d @ 6" OCTYP

MTL STUD WALL, SAD

WOOD STUD WALLCONCRETE KNEE WALL

CONCRETE KNEE WALL 3'-6"

NOM

FLASHING

8d @ 4" OCTYP

SIMPSON .25"x6" SDS@ 6", STAGGERED

6x8 BLOCK

FIRE TREATED1532" APA SHEATING

8d @ 4" OC (2) ROWSTYP

J-BOLT

NOTE:CONTRACTOR TO VERIFY ANDCOORDINATE FOOTING / NEWFOOTING INTERFACE

VARI

ES

VARI

ES

TOCELEV. 97'-0"

TOC @ CONTROL ROOMELEV. 98'-6"

58" DRYWALL

78" HAT CHANNEL

78"

6"

9"

58"

58" DRYWALL

78" HAT CHANNEL

58" DRYWALL

FINISH TRIM, SAD

HANDRAIL, TYP

3'-0"

TYP

FINISH TRIM, SAD#5 @ 12"

#5 @ 16" OC,ALT HOOKS

5'-9" 5'-9"CL CL CL

6"6"6"6"6"

6"1'-0"6"

2'-0"

1'-0"#5 @ 12"

EW

#5 @ 8" OC ALT HOOKS

#5 @ 12"

6"

4'-0"

MAX

HEI

GHT

WAL

L1'-

0"

NOTE:SEE 9/C6.0FOR STAIRDETAILS#5 @ 16" OC ALT HOOKS

#5 @ 12"

5"

2x6 @ 16" OC

8d @ 4" OC TYP

58"Ø SIMPSON TITEN HD

@ 24" OC

SHEETROCK1

2" PLYWOOD

EN 8d @ 4" OC

SIMPSON HI TIESEA JOIST

SIMPSON A35 EA BLOCKING

FULL HEIGHT 2x10 BLOCKING

JOIST PER PLAN

EN 8d @ 4" OC #5 @ 18" OC EW

#5 @ 18" OCALT HOOKS

NEW FOUNDATION

NOTE:EXISTING FOUNDATION TOBE DEMOED

BN 10d @ 4" OC

2x10 RIM @ FASCIA

SIMPSON HI TIES

1'-0"

SHEATHING

2x6 WALL

TO SOGELEV. 0'-0"

CMU WALL

8"

#5 @ 16" OCEW EF TYP

#5 16" OC

EXISTING FOUNDATION

TO FFELEV. 99'-0"

TO RETAING WALLELEV. 100'-0"

TO FFELEV. 97'-0"

(4) R

ISER

S @

6" =

2'-0

"

(3) TREADS @ 11" = 2'-9"

CIP CONCRETERETAINING WALL

CIP CONCRETESTAIRS ON GRADE

NOTE:SAD A501 FOR ADDITIONALDETAILS STAIRS, GRANULAR FILL

S5.213

2'-10

"

2'-9"

(3) R

ISER

S @

6" =

1'-6

"

HANDRAIL, SAD

CIP CONCRETESTAIRS ON GRADE

1'-0"

11"11"1"

2'-10

"3'-71 2"

TRIM, SAD

HANDRAIL CONNECTION,SAD

TOCELEV. 97'-0"

STAIR TREAD, SAD

S5.213

2'-10

"

5'-6"

(5) TREADS @ 11" = 4'-7"

(6) R

ISER

S @

6" =

3'-0

"

HANDRAIL, SAD

PARTIAL HEIGHT WALL, SAD

CIP CONCRETESTAIRS ON GRADE

1'-0"

6'-6"

11" 11" 1"

2'-10

" 3'-71 2"

TRIM, SAD

HANDRAIL CONNECTION, SAD

STAIR TREAD, SAD

TOCELEV. 97'-0"

TOCELEV. 100'-0"

CIP CONCRETESTAIRS ON GRADE

(1) TREADS @ 11" = 11"

(2) R

ISER

S @

6" =

1'-0

"

3'-0"

1'-0"

4'-0"

1'-10" 3'-958"

5'-758"

1" SCH 40 PIPE HANDRAIL

NOTE:SAD A304, A411 FOR ADDITIONALDETAILS STAIRS, GRANULAR FILL

(6) R

ISER

S @

6" =

3'-0

"

6" 4'-2" 6"

5'-2"

3'-71 2"

6'-71 2"

PARTIAL HEIGHTWALL, SAD

NOTE:REFERENCE FORSTAIRS WITH(3) TREADS@ 6" = 1'-6"

#5 @ 18" OCALT HOOKS #5 @ 18" OC EW

(2) #5 16" OC

1'-0"

11"

5"

2'-4"

3'-0" TYP

6'-0"

1'-0" TYP

HSS 6x6x38

INSULATION SAD

5"REF

© 2017 JOHNSON BRODERICK ENGINEERING. No part of this document can be reproduced without the written permission from JBE, [ 325 WEST 13TH AVENUE EUGENE OREGON, 97401. (541)338-9488 or fax (541)338-9483 ]

Proje

ct:

THE DOCUMENT AND THE DESIGNS

INCORPORATED HEREIN ARE THE

PROPERTY OF JOHNSON BRODERICK

ENGINEERING, LLC, AND IS NOT TO BE

USED, IN WHOLE OR PART, FOR ANY

OTHER PROJECT WITHOUT THE

WRITTEN AUTHORIZATION FROM THE

PRINCIPALS OF JOHNSON BRODERICK

ENGINEERING

JBE

JOHN

SON

BROD

ERIC

KEN

GINE

ERIN

GC

iv

il an

d S

tru

ctu

ral E

ng

in

eers

325 W

. 13th

Ave

Euge

ne, O

r 974

01-3

402

Tel (5

41) 3

38-9

488

Fax (

541)

338-

9483

www.

JBE.

US.co

m

Project No:

Drawn By:

Sheet title:

Checked By:

Date:

Date

Revis

ions

Symb

olBy

17095.01

JW

AMB

S5.2

CONS

TRUC

TION

SET

4/20/2

018WR

S

4/20/2018

CONCRETEDETAILS

KVAL

ADD

ITIO

NS &

ALT

ERAT

IONS

4575

BLA

NTON

ROA

DEU

GENE

, OR

9740

5

S5.21 FOUNDATION @ GRID C

3/4" = 1'-0"

S5.27 STAIRS @ RETAINING WALL

3/4"=1'-0"

S5.213 STAIRS, (3) & (6) TREADS

S5.214 STAIRS EXISTING BUILDING

3/4"=1'-0"

S5.217 EXTERIOR WALL @ WORK SHOP, WALL JOIST DETAIL

S5.219 FOOTING, FOUNDATION, HSS DETAIL

3/4" = 1'-0"

S5.24 FOUNDATION, CMU WALL DETAIL

3/4" = 1'-0" S5.28 STAIR SECTION DETAIL

3/4" = 1'-0"

S5.211 STAIR SECTION DETAILS

3/4"=1'-0"

S5.23 RETAINING WALL @ STAIRS

3/4" = 1'-0"

2

\\JBE

-06\J

BE -

Proje

cts\17

095.x

x - S

ande

rs De

sign\1

7095

.01 -

4575

Blan

ton R

oad\D

rawi

ngs\C

ad\C

ONST

SET

4-20

-201

8\170

95.01

- KV

AL A

dditio

n - S

5 SER

IES.

dwg,

4/20/2

018 2

:49:18

PM

Page 10: THE DOCUMENT AND THE DESIGNS INCORPORATED HEREIN … · 2018-04-24 · system at the construction stages indicated in the structural observation table and at completion of the structural

VARIES

VARI

ES

S6.012

6x

CORNER

6x C

ORNE

R PO

ST

OPEN

4 x 8 UNO

A23 OR A35TYP, OMIT @

INT WALLSLTS18@ EXTERIORCORNERS

2x TRIMMER U.O.N.

16d @ 12" STAGGER

HEADERPER PLAN

MIN. 2x BEARINGSTUD

(3)-16dEND NAIL

TYP

(2) 2x TOPPLATE

HUCHANGER

SP2 @TRIMMERSON EXTWALLS

1 2"

1 2" 1 2"1 2"

2"

1 2"

1 2"

23 4"

NOTE: 1 0.229" X 3" X 3"

PLATE WASHER

2 0.229" X 3" X 4 12"PLATE WASHER

WALL SHEATHED BOTH SIDES

WALL SHEATHED ONE SIDE

3"

41 2"

STAG

GERE

DAN

CHOR

ROD

S

BOLT OFFSET BOLT CENTERED

BOLT OFFSET BOLT CENTERED1

2

1

1

2

A B

DC

1'-6"

2x JOISTS34" PLY

34" PLY

SIMPSON TITEN HD6" FROM ENDSAND 2'-0" OC

SLAB

NOTE: 1 6" MIN + 12" MAX 2 4' - 0" OC MAX UNO

3 TYP ANCHOR BOLT = 5 8" x 10" THREADED RODIN SIMPSON SET-XP EPOXY. SPECIALINSPECTION REQUIRED

1 2 1 1 2

1

21 2

BEARING WALL

NON - BEARING WALL

BORED HOLESD

A

BORED HOLE MAX DIA 60PERCENT OF STUD DEPTH

E

NOTCHESB

BOLT OFFSETF

BOLT OFFSETC

58" MIN

TO EDGE

BORED HOLES

NOTCHES

NOTCH MUST NOTEXCEED 40 PERCENT

OF STUD DEPTH

BORED HOLES SHALL NOTBE LOCATED IN THE SAMECROSS SECTION OF CUTOR NOTCH IN STUD

BORED HOLE MAX DIA 40PERCENT OF STUD DEPTH

58" MIN

TO EDGE

NOTCH MUST NOTEXCEED 25 PERCENT

OF STUD DEPTH

BORED HOLES SHALL NOTBE LOCATED IN THE SAMECROSS SECTION OF CUTOR NOTCH IN STUD

IF BORED HOLE IS BETWEEN 40 PERCENT AND 60 PERCENT OF STUD DEPTH , THEN STUD MUSTBE DOUBLE AND NO MORE THAN TWO SUCCESSIVE STUDS ARE DOUBLED AND SO BORED

A TYPICAL WALL ELEVATIONOF TOP PLATE SPLICE

B WALL CORNER/ INTERSECTIONELEVATION

4'-0" MIN OVERLAP℄ STUD ℄ STUD

C TYPICAL STUD SECTION ATEXTERIOR WALL CORNER

(10) 16d STAGGER

(4) 16dCONT.

CONT.

INTERIOR NON - BEARING PARTION

LOWER TOP PLATE CONTINUOUSTHROUGH INTERSECTION

2 x 8

CONTINUOUS DOUBLE TOPPLATE THROUGH INTERSECTION

INTERSECTING WALL

LOWER TOP PLATE CONTINUOUSTHROUGH INTERSECTION

(4) 16dCONT.

CONT.

A WALL CORNER/ INTERSECTIONELEVATION

B BEARING WALL INTERSECTIONPLAN

L / 3

L / 8

D / 4

L / 6 MIN L / 6 MIN

8X HOLEØ MIN

D

L

REGION WHERE1" Ø MAX FIELDDRILLED HOLES AREPERMITTED FORPASSAGE OFCONDUIT, WIRE, ETC

NOTES:1. NO HOLES IN CANTILEVER ENDS2. 1" Ø HOLE MAX3. MAXIMUM NUMBER OF HOLES = L / 54. ENGINEER MAY APPROVE HOLES NOT COMPLYING WITH ABOVE5. NOTCHING NOT ALLOWED EXCEPT:

WOOD (NOT GL) BEAMS OR JOISTS MAY HAVE A 1" DEEP MAX & 3" LONGMAX NOTCH ON THE TOP OR BOTTOM SIDE NOT IN THE MIDDLE THIRD OF THE SPAN

6.NO HOLES OR NOTCHES ARE PERMITTED IN TJI'S, LVL'S, LSL'S ORGANGNAIL TRUSSES EXCEPT AS PERMITTED BY THE MANUFATURER

NOTE 5

D / 4

6.01 ALLOWABLE BEAM HOLES AND NOTCHES

1" = 1'-0"

6.02 WALL INTERSECTIONS

1" = 1'-0"

6.03 ALLOWABLE BEAM HOLES AND NOTCHES

1" = 1'-0"

6.05 ALLOWABLE STUD HOLES AND NOTCHES

1" = 1'-0"

6.06 TYP WALL FRAMING

1" = 1'-0"

6.07 NOT USED

6.04 NOT USED

6.08 ANCHOR BOLT LAYOUT

1" = 1'-0"

6.09 ALLOWABLE STUD HOLES AND NOTCHES

1" = 1'-0"

6.010 TYP WALL FRAMING

1" = 1'-0"

6.011 NOT USED

6.012 WOOD PLATFORM SECTION

1" = 1'-0"

6.013 NOT USED

6.015 NOT USED

6.016 WOOD PLATFORM PLAN

1" = 1'-0"

6.014 NOT USED

3/4" = 1'-0"

© 2017 JOHNSON BRODERICK ENGINEERING. No part of this document can be reproduced without the written permission from JBE, [ 325 WEST 13TH AVENUE EUGENE OREGON, 97401. (541)338-9488 or fax (541)338-9483 ]

Proje

ct:

THE DOCUMENT AND THE DESIGNS

INCORPORATED HEREIN ARE THE

PROPERTY OF JOHNSON BRODERICK

ENGINEERING, LLC, AND IS NOT TO BE

USED, IN WHOLE OR PART, FOR ANY

OTHER PROJECT WITHOUT THE

WRITTEN AUTHORIZATION FROM THE

PRINCIPALS OF JOHNSON BRODERICK

ENGINEERING

JBE

JOHN

SON

BROD

ERIC

KEN

GINE

ERIN

GC

iv

il an

d S

tru

ctu

ral E

ng

in

eers

325 W

. 13th

Ave

Euge

ne, O

r 974

01-3

402

Tel (5

41) 3

38-9

488

Fax (

541)

338-

9483

www.

JBE.

US.co

m

Project No:

Drawn By:

Sheet title:

Checked By:

Date:

Date

Revis

ions

Symb

olBy

17095.01

JW

AMB

S6.0

CONS

TRUC

TION

SET

4/20/2

018WR

S

4/20/2018

WOODDETAILS

KVAL

ADD

ITIO

NS &

ALT

ERAT

IONS

4575

BLA

NTON

ROA

DEU

GENE

, OR

9740

5

\\JBE

-06\J

BE -

Proje

cts\17

095.x

x - S

ande

rs De

sign\1

7095

.01 -

4575

Blan

ton R

oad\D

rawi

ngs\C

ad\C

ONST

SET

4-20

-201

8\170

95.01

- KV

AL A

dditio

n - S

6 SER

IES.

dwg,

4/20/2

018 2

:51:10

PM

Page 11: THE DOCUMENT AND THE DESIGNS INCORPORATED HEREIN … · 2018-04-24 · system at the construction stages indicated in the structural observation table and at completion of the structural

W16x

C COLUMNC BEAM

C COLUMNC GIRDERLL

LL

P SLOT THRU HSSL

TAB P SLOT INTO HSSL

TYP

BEAM TAB P SIDE AS OCCURS(9" DEEP FOR 3 BOLT CONNECTION)

L

112"

4"W14X

CONC/STEEL DECKNOT SHOWN

3 4" W/ (4) 7 8"Ø HSB @ BEAM GAGE⅊1/4

HSS 4X

COLUMN PER PLAN

HEAVY NUT & WASHER

LEVELING NUT

DOUBLE HEAVY NUTAND WASHER

3" MIN 5" MA

X

TO FOOTING

112" NON-SHRINK

GROUT

BO FOOTING

SLAB

SLAB & FTGREINF NOT SHOWN

NOTE: 1. SEE 1/S7.1 FOR PLATE AND BOLT INFORMATION 2. SEE 13/S5.0 FOR FOOTING INFORMATION

S7.01 CANTILEVERED GIRDER

1" = 1'-0"

© 2017 JOHNSON BRODERICK ENGINEERING. No part of this document can be reproduced without the written permission from JBE, [ 325 WEST 13TH AVENUE EUGENE OREGON, 97401. (541)338-9488 or fax (541)338-9483 ]

Proje

ct:

THE DOCUMENT AND THE DESIGNS

INCORPORATED HEREIN ARE THE

PROPERTY OF JOHNSON BRODERICK

ENGINEERING, LLC, AND IS NOT TO BE

USED, IN WHOLE OR PART, FOR ANY

OTHER PROJECT WITHOUT THE

WRITTEN AUTHORIZATION FROM THE

PRINCIPALS OF JOHNSON BRODERICK

ENGINEERING

JBE

JOHN

SON

BROD

ERIC

KEN

GINE

ERIN

GC

iv

il an

d S

tru

ctu

ral E

ng

in

eers

325 W

. 13th

Ave

Euge

ne, O

r 974

01-3

402

Tel (5

41) 3

38-9

488

Fax (

541)

338-

9483

www.

JBE.

US.co

m

Project No:

Drawn By:

Sheet title:

Checked By:

Date:

Date

Revis

ions

Symb

olBy

17095.01

JW

AMB

S7.0

CONS

TRUC

TION

SET

4/20/2

018JW

4/20/2018

STEELDETAILS

KVAL

ADD

ITIO

NS &

ALT

ERAT

IONS

4575

BLA

NTON

ROA

DEU

GENE

, OR

9740

5

S7.02 TYP. BEAM/GIRDER/COLUMN CONNECTION

1" = 1'-0"

S7.03 COLUMN BASE DETAIL

1" = 1'-0"

K1 PER AISC

CONNECTION

END OF KNIFEPLATE AT ONE SIDE

1/2"

BOLTS SEE SCHEDFOR SHEAR PLATE AND

SEE SCHED

SEE SCHED

1/2"

PROVIDE 3/8" CAP PLATE@ TUBE END TYP

1-1/2" 2-1/2"

PLATE AT ONE SIDECONNECTION

END OF KNIFE

TYP @CAP P

FOR SHEAR PLATE ANDBOLTS SEE SCHED

1/4

TYP

1/2"1-1/2"

TYP

1/2"

3"3"

SEE SCHED

1-1/2"

1-1/2" MIN.

2"

TYP

3"3"

TYP

SEE SCHED

BEAMS IN OTHER CONN. PLATE TO SUPPORT

DIRECTION SEE PLANS

W16

W33

W27

W21

W18

W14

W12

L4 L7

SIZEBEAM

FOR SHEAR PLATE ANDBOLTS SEE SCHED

1/2"

TYP3"3"

2-1/2" 1-1/2"

SCHEDSEE

1/4

1/4

SIZEWELD

1/2

5/16

1/2

1/2

3/8

5/16

3/8

1/2" (4) 7/8"Ø

(7) 7/8"Ø

(9) 7/8"Ø

(5) 7/8"Ø

(4) 7/8"Ø

3/4"

5/8"

5/8"

1/2"

(2) 7/8"Ø

(3) 7/8"Ø

(3) 7/8"Ø

NO.& SIZEOF BOLTSREQUIRED

(2) 7/8"Ø

3/8"

3/8"

3/8"

THICKNESSPLATE

1/4"

STANDARD BOLTED CONNECTION SCHEDULE

W10C10

TS COL℄

TS COL℄

FRAME GIRDER℄

S7.05 DRAG @ B,1, & C

S7.06 NOT USED

S7.07 NOT USED

S7.08 BEAM TO HSS COLUMN

S7.09 BEAM TO BEAM

S7.010 NOT USED

S7.011 NOT USED

S7.012 NOT USED

S7.04 BOLT CONNECTION SCHEDULE

3"

\\JBE

-06\J

BE -

Proje

cts\17

095.x

x - S

ande

rs De

sign\1

7095

.01 -

4575

Blan

ton R

oad\D

rawi

ngs\C

ad\C

ONST

SET

4-20

-201

8\170

95.01

- KV

AL A

dditio

n - S

7 SER

IES.

dwg,

4/20/2

018 2

:52:59

PM

AutoCAD SHX Text
3/16
AutoCAD SHX Text
3/16
AutoCAD SHX Text
%%U PLAN
Page 12: THE DOCUMENT AND THE DESIGNS INCORPORATED HEREIN … · 2018-04-24 · system at the construction stages indicated in the structural observation table and at completion of the structural

2" TYP.3" TY

P.

Wx COL. BELOW

3" 2"

41 4"GA

GE

12"

3"TYP.

CAP PLATE Wx BEAM

(2) ROWS OF (4) 7 8" ØA490-X BOLTS AT TOP &BOT. OF BEAM FLANGE

NOTE:SHEAR PLATE,BOLTS & WELD - SEESCHED. ON DETAIL

S7.07

P 3 4" x

P 3 4" xP 3 4" STIFFEA. SIDE

C COLL

BEAM TO COLUMNMOMENT

ELEVATION

PLAN AT CAP PLATE

L

L

L

12" WEBDOUBLERPLATE

2"

BACKGOUGE

BACKGOUGE

BACKGOUGE

WHERE OCCURS PER PLAN

SPLIT STIFFENER @ TAB

1'-2"

1'-2"

C COLL

C C

OLL

2"

2"

1"Ø x 24"ANCHOR BOLT TYP

1" PL

W10x

1'-0"

1'-0"

C COLL

C C

OLL

11 2"

112"

34"Ø x 14"

ANCHOR BOLT TYP3

4" PL

HSS6x

9"

9"

C COLL

C C

OLL

11 2"

112"

34"Ø x 14"

ANCHOR BOLT TYP3

4" PL

HSS4x

BACKGOUGE

OPEN WEB STEELJOIST PER PLAN

ROOF DECKPER PLAN

W18X

1/4TYP

1/4TYP1/4

1/4

1/4TYP 2-6

P 3 8"x312"x0'-8" TYPL

OPEN WEB STEELJOIST PER PLAN

ROOF DECKPER PLAN

W18X

1/4TYP 1/4

1/4TYP 2-6 P 3 8"x312"x0'-8"

TYPL

ROOF DECKPER PLAN

W18X

HSS 6X

1/4TYP

1/4 TYP1/4

1/4

OPEN WEB STEELJOIST PER PLAN

W18X

2"

P 5 16"x4"x1'-2"

OPEN WEB STEELJOIST PER PLAN

ROOF DECKPER PLAN

W16X

P 5 16"x4"x1'-1"

1/41/4

1/4 CAP

P 3 8"x612"x61

2"

HSS 6X

W18X

L

L

L

DRAG PLATEP 12"x4"x4'-0"L

P 3 4"x8"x0'-8"L

LSH

L3 x 2 12 X 14 (LLH) - VERIFY

OPEN WEB STEELJOIST PER PLAN

ROOF DECKPER PLAN

W18x50

W8x24

1" 1"21 4"

41 4"

4"11

2"

12"

(2) Ø7 8" H

OLES

516"x4"x4 14" A36 PL

W18x50

W8x24

OPEN WEB STEELJOIST PER PLAN

ROOF DECKPER PLAN

ROOF DECKPER PLAN

38"x11"x11" A36

CAP

112"

10"

212" 11

2"

4"

13 8"

11 2"3"

11 2"3"

1'-1"

12"

516"x4"x13" A36 PL

(4) Ø7 8"

HOLES

W18x50

W10x60

W16x26

12"

11"

12"

212"11

2"

4"

11 2"(4

) SPC

'S. @

2 3 4" =

11"

1'-2"

(5) Ø 78 " HOLES

516"x4"x14" A36 PL

W10x60

W16x26

W18x50

W18x50

W16x26W16x26HSSx6x6x3/8

14"

612"

11 4"

11 2"3"

11 2"3"

1'-1"

212" 11

2"

4"

(4) Ø7 8" H

OLES

516"x4"x13" A36 PL

212" 11

2"

4"

2"

11 2"(4

) SPC

'S @

2 3 4" =

11"

(5) Ø

7 8" HOLE

S

HSSx6x6x3/8 516"x4"x14" A36 PL

38"x6 12"x6 12" A36

CAP

12"

12"

1'-2"

W18X

HSS 6X

W16X

1/4

P 3 8"x612"x0'-61

2"

HSS 6X

W16X

W18XP 5 16"x4"x1'-1"

P 5 16"x4"x1'-2"

L

L

L

OPEN WEB STEELJOIST PER PLAN

ROOF DECKPER PLAN

W18X

1/4TYP

1/4TYP1/4

1/4

W8x

HSS 6X

ROOF DECKPER PLAN

W18X

HSS 6X

1/4TYP

1/4 TYP1/4

1/4

OPEN WEB STEELJOIST PER PLAN

P 516"x4"x1'-2"

1/41/4

P 3 8"x612"x0'-61

2"

1/4P 516"x4"x0'-41

4"L

L

L

© 2017 JOHNSON BRODERICK ENGINEERING. No part of this document can be reproduced without the written permission from JBE, [ 325 WEST 13TH AVENUE EUGENE OREGON, 97401. (541)338-9488 or fax (541)338-9483 ]

Proje

ct:

THE DOCUMENT AND THE DESIGNS

INCORPORATED HEREIN ARE THE

PROPERTY OF JOHNSON BRODERICK

ENGINEERING, LLC, AND IS NOT TO BE

USED, IN WHOLE OR PART, FOR ANY

OTHER PROJECT WITHOUT THE

WRITTEN AUTHORIZATION FROM THE

PRINCIPALS OF JOHNSON BRODERICK

ENGINEERING

JBE

JOHN

SON

BROD

ERIC

KEN

GINE

ERIN

GC

iv

il an

d S

tru

ctu

ral E

ng

in

eers

325 W

. 13th

Ave

Euge

ne, O

r 974

01-3

402

Tel (5

41) 3

38-9

488

Fax (

541)

338-

9483

www.

JBE.

US.co

m

Project No:

Drawn By:

Sheet title:

Checked By:

Date:

Date

Revis

ions

Symb

olBy

17095.01

JW

AMB

S7.1

CONS

TRUC

TION

SET

4/20/2

018WR

S

4/20/2018

STEELSPECIFICDETAILS

KVAL

ADD

ITIO

NS &

ALT

ERAT

IONS

4575

BLA

NTON

ROA

DEU

GENE

, OR

9740

5

S7.13 TRUSS BEARING @ GRIDS A,B, & C

1" = 1'-0"

S7.14 BEAM CONNECTION @ GRIDS A & 2

S7.12 BEAM CONNECTION @ GRIDS 1A, 1A.8, 2A, 3C, 4B.5, C

1" = 1'-0"

S7.11 BASE PLATES

1" = 1'-0"

S7.16 BEAM CONNECTION @ GRID B & 2

1" = 1'-0"

S7.17 NOT USED

S7.18 BEAM CONNECTION @ GRIDS B2

1" = 1'-0"

S7.19 BEAM CONNECTION @ GRIDS B & 4

S7.111 BEAM CONNECTION @ GRID C

1" = 1'-0"

S7.110 BEAM CONNECTION @ GRID C

S7.15 BEAM CONNECTION @ GRIDS A & 1

\\JBE

-06\J

BE -

Proje

cts\17

095.x

x - S

ande

rs De

sign\1

7095

.01 -

4575

Blan

ton R

oad\D

rawi

ngs\C

ad\C

ONST

SET

4-20

-201

8\170

95.01

- KV

AL A

dditio

n - S

7 SER

IES.

dwg,

4/20/2

018 2

:54:10

PM

AutoCAD SHX Text
TYP
AutoCAD SHX Text
CP
AutoCAD SHX Text
TYP
AutoCAD SHX Text
CP
AutoCAD SHX Text
TYP
AutoCAD SHX Text
CP
AutoCAD SHX Text
TYP
AutoCAD SHX Text
CP
AutoCAD SHX Text
1/4
AutoCAD SHX Text
TYP
AutoCAD SHX Text
1/4
AutoCAD SHX Text
TYP
AutoCAD SHX Text
1/4
AutoCAD SHX Text
1/4
AutoCAD SHX Text
1/4
AutoCAD SHX Text
1/4
AutoCAD SHX Text
1/4
AutoCAD SHX Text
TYP
AutoCAD SHX Text
1/4
AutoCAD SHX Text
1/4
AutoCAD SHX Text
1/4
AutoCAD SHX Text
1/4
AutoCAD SHX Text
1/4
AutoCAD SHX Text
1/4
AutoCAD SHX Text
1/4
AutoCAD SHX Text
1/4
AutoCAD SHX Text
1/4
AutoCAD SHX Text
1/4
AutoCAD SHX Text
1/4
Page 13: THE DOCUMENT AND THE DESIGNS INCORPORATED HEREIN … · 2018-04-24 · system at the construction stages indicated in the structural observation table and at completion of the structural

3'-3"

SAD

SADHSS 6xELSE W10X

HSS 6x6x38

S7.26

S7.26

SEE FOR ADDITIONAL INFORMATIONS7.27

2x10 JOISTS

EXISTING PRECAST PLANK

SIMPSON TOP-FLANGE HANGERHU210TF

NOTE: DO NOT CUT TENSIONED REINFORCING @ PLANK

LEDGER, 2x12

INSULATION, 1" THK

BALLAST PAVER 24x24

12 PLYWOOD

4" INSULATION

ROOF MEMBRANEWOOD BLOCKING1x4, 2x4, 2x4

EXPANSION ANCHOR 12"

HSS 6x, WF WHERE OCCURSSEE PLAN

GRIDGRID

HSS 6x6x3/8

STUDWALL

DECK PER PLANS

4x6 NAILER

4x6 NAILERCAP, P 14"x 5 12"x 5 12"

14"x5" SELF TAPPING SCREWS

GRID

GRID

W10x

HSS 6x6x3/8

STUDWALL

DECK PER PLANS

4x6 NAILER

4x6 NAILERCAP, P 14"x 5 12"x 5 12"

14"x5" SELF TAPPING SCREWS

HSS 6x6

L3 x 2 12 x 14 (LLH) - VERIFY

OPEN WEB STEELJOIST PER PLAN

ROOF DECKPER PLAN

W18x50

2'-6"

HSS 6

P 3 8x3 12x8, TYP

12" CMU WALL

B

L

58"Ø @ 32" OC

L 4"X4"X14" CONT

W/ LONGSLOTTED HOLE

(E) CMU WALL

2'-6"

W18x50W10x60

L3 x 2 12 x 14 (LLH) - VERIFY

ROOF DECKPER PLAN

OPEN WEB STEELJOIST PER PLAN

C

OPEN WEB STEELJOIST PER PLAN

NOTE:MIN. SNOW DRIFTING HEIGHT @ FINISHEDROOF = 4'-6", COORDINATE FINISH W/ ARCH

CLOSUREANGLE, SADFOR FLASHING

© 2017 JOHNSON BRODERICK ENGINEERING. No part of this document can be reproduced without the written permission from JBE, [ 325 WEST 13TH AVENUE EUGENE OREGON, 97401. (541)338-9488 or fax (541)338-9483 ]

Proje

ct:

THE DOCUMENT AND THE DESIGNS

INCORPORATED HEREIN ARE THE

PROPERTY OF JOHNSON BRODERICK

ENGINEERING, LLC, AND IS NOT TO BE

USED, IN WHOLE OR PART, FOR ANY

OTHER PROJECT WITHOUT THE

WRITTEN AUTHORIZATION FROM THE

PRINCIPALS OF JOHNSON BRODERICK

ENGINEERING

JBE

JOHN

SON

BROD

ERIC

KEN

GINE

ERIN

GC

iv

il an

d S

tru

ctu

ral E

ng

in

eers

325 W

. 13th

Ave

Euge

ne, O

r 974

01-3

402

Tel (5

41) 3

38-9

488

Fax (

541)

338-

9483

www.

JBE.

US.co

m

Project No:

Drawn By:

Sheet title:

Checked By:

Date:

Date

Revis

ions

Symb

olBy

17095.01

JW

AMB

S7.2

CONS

TRUC

TION

SET

4/20/2

018WR

S

4/20/2018

STEELSPECIFICDETAILS

KVAL

ADD

ITIO

NS &

ALT

ERAT

IONS

4575

BLA

NTON

ROA

DEU

GENE

, OR

9740

5

S7.21 NOT USED

S7.22 EAVE DETAIL

1" = 1'-0"

S7.23 NOT USED

S7.24 REPAIR & SHOP

1" = 1'-0"

S7.27 BROW @ CORNER

1" = 1'-0"

S7.28 BEAM CONNECTION @ GRID B

3/4" = 1'-0"

S7.26 PLAN @ BROW

1" = 1'-0"S7.211 BEAM CONNECTION @ GRID C

3/4" = 1'-0"

S7.212 NOT USED

S7.215 NOT USED

S7.216 NOT USED

S7.218 NOT USED

S7.219 NOT USED

S7.220 NOT USED

S7.217 NOT USED

\\JBE

-06\J

BE -

Proje

cts\17

095.x

x - S

ande

rs De

sign\1

7095

.01 -

4575

Blan

ton R

oad\D

rawi

ngs\C

ad\C

ONST

SET

4-20

-201

8\170

95.01

- KV

AL A

dditio

n - S

7 SER

IES.

dwg,

4/20/2

018 2

:56:44

PM

AutoCAD SHX Text
CP
AutoCAD SHX Text
TYP
AutoCAD SHX Text
1/4
AutoCAD SHX Text
TYP
AutoCAD SHX Text
1/4
AutoCAD SHX Text
TYP
AutoCAD SHX Text
1/4
AutoCAD SHX Text
TYP
AutoCAD SHX Text
1/4
AutoCAD SHX Text
TYP
AutoCAD SHX Text
1/4
AutoCAD SHX Text
TYP
AutoCAD SHX Text
G
AutoCAD SHX Text
TYP
AutoCAD SHX Text
1/4
AutoCAD SHX Text
TYP
AutoCAD SHX Text
G
AutoCAD SHX Text
1/4
AutoCAD SHX Text
TYP
AutoCAD SHX Text
1/4
AutoCAD SHX Text
2-6
AutoCAD SHX Text
TYP
AutoCAD SHX Text
1/4
AutoCAD SHX Text
TYP
AutoCAD SHX Text
1/4
AutoCAD SHX Text
1/4
AutoCAD SHX Text
TYP
AutoCAD SHX Text
1/4
AutoCAD SHX Text
1/4
AutoCAD SHX Text
2-6
AutoCAD SHX Text
TYP
AutoCAD SHX Text
1/4
AutoCAD SHX Text
TYP
AutoCAD SHX Text
1/4
AutoCAD SHX Text
1/4
AutoCAD SHX Text
TYP
AutoCAD SHX Text
1/4
Page 14: THE DOCUMENT AND THE DESIGNS INCORPORATED HEREIN … · 2018-04-24 · system at the construction stages indicated in the structural observation table and at completion of the structural

D L

H L 12

D R

L DL

L P1

L P2

L P3

L P4

L

12

R

L DR

P1 P2 P3 P4

DLLLSL

DLLL

LENGTH

P1

AXIAL AXIAL

P2 P3

L P1

L P2

L P3

L P4

P4

HR

© 2017 JOHNSON BRODERICK ENGINEERING. No part of this document can be reproduced without the written permission from JBE, [ 325 WEST 13TH AVENUE EUGENE OREGON, 97401. (541)338-9488 or fax (541)338-9483 ]

Proje

ct:

THE DOCUMENT AND THE DESIGNS

INCORPORATED HEREIN ARE THE

PROPERTY OF JOHNSON BRODERICK

ENGINEERING, LLC, AND IS NOT TO BE

USED, IN WHOLE OR PART, FOR ANY

OTHER PROJECT WITHOUT THE

WRITTEN AUTHORIZATION FROM THE

PRINCIPALS OF JOHNSON BRODERICK

ENGINEERING

JBE

JOHN

SON

BROD

ERIC

KEN

GINE

ERIN

GC

iv

il an

d S

tru

ctu

ral E

ng

in

eers

325 W

. 13th

Ave

Euge

ne, O

r 974

01-3

402

Tel (5

41) 3

38-9

488

Fax (

541)

338-

9483

www.

JBE.

US.co

m

Project No:

Drawn By:

Sheet title:

Checked By:

Date:

Date

Revis

ions

Symb

olBy

17095.01

JW

AMB

S7.3

CONS

TRUC

TION

SET

4/20/2

018WR

S

4/20/2018

JOISTLOADING

TABLE

KVAL

ADD

ITIO

NS &

ALT

ERAT

IONS

4575

BLA

NTON

ROA

DEU

GENE

, OR

9740

5

S7.31 JOIST LOADING

NOT TO SCALE

S7.32 JOIST LOADING TABLE

NOT TO SCALE

\\JBE

-06\J

BE -

Proje

cts\17

095.x

x - S

ande

rs De

sign\1

7095

.01 -

4575

Blan

ton R

oad\D

rawi

ngs\C

ad\C

ONST

SET

4-20

-201

8\170

95.01

- KV

AL A

dditio

n - S

7 SER

IES.

dwg,

4/20/2

018 2

:57:59

PM

AutoCAD SHX Text
JOIST LOADING TABLE
AutoCAD SHX Text
JOIST
AutoCAD SHX Text
BEARING
AutoCAD SHX Text
TOP CHORD LOADING
AutoCAD SHX Text
BOTTOM CHORD LOADING
AutoCAD SHX Text
NOTES:
AutoCAD SHX Text
LEFT
AutoCAD SHX Text
RIGHT
AutoCAD SHX Text
SNOW DRIFT LOAD
AutoCAD SHX Text
TOP CHORD POINT LOADS
AutoCAD SHX Text
BOTTOM CHORD POINT LOADS
AutoCAD SHX Text
#
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
LENGTH
AutoCAD SHX Text
CAMBER
AutoCAD SHX Text
DEPTH
AutoCAD SHX Text
MATERIAL
AutoCAD SHX Text
H L
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text
MATERIAL
AutoCAD SHX Text
H R
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text
DL
AutoCAD SHX Text
LL
AutoCAD SHX Text
SL
AutoCAD SHX Text
D L
AutoCAD SHX Text
L L
AutoCAD SHX Text
D R
AutoCAD SHX Text
L R
AutoCAD SHX Text
P 1
AutoCAD SHX Text
L 1
AutoCAD SHX Text
P 2
AutoCAD SHX Text
L 2
AutoCAD SHX Text
P 3
AutoCAD SHX Text
L 3
AutoCAD SHX Text
P 4
AutoCAD SHX Text
L 4
AutoCAD SHX Text
AXIAL
AutoCAD SHX Text
DL
AutoCAD SHX Text
LL
AutoCAD SHX Text
P 1
AutoCAD SHX Text
L 1
AutoCAD SHX Text
P 2
AutoCAD SHX Text
L 2
AutoCAD SHX Text
P 3
AutoCAD SHX Text
L 3
AutoCAD SHX Text
P 4
AutoCAD SHX Text
L 4
AutoCAD SHX Text
(Ft-In)
AutoCAD SHX Text
(In)
AutoCAD SHX Text
(In)
AutoCAD SHX Text
(In)
AutoCAD SHX Text
DEGREES
AutoCAD SHX Text
(In)
AutoCAD SHX Text
H : L
AutoCAD SHX Text
(plf)
AutoCAD SHX Text
(plf)
AutoCAD SHX Text
(plf)
AutoCAD SHX Text
(plf)
AutoCAD SHX Text
(ft)
AutoCAD SHX Text
(plf)
AutoCAD SHX Text
(ft)
AutoCAD SHX Text
(lb)
AutoCAD SHX Text
(ft)
AutoCAD SHX Text
(lb)
AutoCAD SHX Text
(ft)
AutoCAD SHX Text
(lb)
AutoCAD SHX Text
(ft)
AutoCAD SHX Text
(lb)
AutoCAD SHX Text
(ft)
AutoCAD SHX Text
(kips)
AutoCAD SHX Text
(plf)
AutoCAD SHX Text
(plf)
AutoCAD SHX Text
(lb)
AutoCAD SHX Text
(ft)
AutoCAD SHX Text
(lb)
AutoCAD SHX Text
(ft)
AutoCAD SHX Text
(lb)
AutoCAD SHX Text
(ft)
AutoCAD SHX Text
(lb)
AutoCAD SHX Text
(ft)
AutoCAD SHX Text
J01
AutoCAD SHX Text
LH
AutoCAD SHX Text
43'-4"
AutoCAD SHX Text
STANDARD
AutoCAD SHX Text
32
AutoCAD SHX Text
MASONRY
AutoCAD SHX Text
34 : 12
AutoCAD SHX Text
MASONRY
AutoCAD SHX Text
34 : 12
AutoCAD SHX Text
152
AutoCAD SHX Text
100
AutoCAD SHX Text
240
AutoCAD SHX Text
50
AutoCAD SHX Text
250
AutoCAD SHX Text
1,3,5
AutoCAD SHX Text
J02
AutoCAD SHX Text
LH
AutoCAD SHX Text
41'-0"
AutoCAD SHX Text
STANDARD
AutoCAD SHX Text
32
AutoCAD SHX Text
0
AutoCAD SHX Text
0
AutoCAD SHX Text
169
AutoCAD SHX Text
100
AutoCAD SHX Text
267
AutoCAD SHX Text
547
AutoCAD SHX Text
19
AutoCAD SHX Text
427
AutoCAD SHX Text
10
AutoCAD SHX Text
*
AutoCAD SHX Text
*
AutoCAD SHX Text
*
AutoCAD SHX Text
*
AutoCAD SHX Text
50
AutoCAD SHX Text
50
AutoCAD SHX Text
4*
AutoCAD SHX Text
JO3
AutoCAD SHX Text
LH
AutoCAD SHX Text
41'-0"
AutoCAD SHX Text
STANDARD
AutoCAD SHX Text
32
AutoCAD SHX Text
0
AutoCAD SHX Text
0
AutoCAD SHX Text
174
AutoCAD SHX Text
100
AutoCAD SHX Text
274
AutoCAD SHX Text
461
AutoCAD SHX Text
19
AutoCAD SHX Text
438
AutoCAD SHX Text
10
AutoCAD SHX Text
*
AutoCAD SHX Text
*
AutoCAD SHX Text
*
AutoCAD SHX Text
*
AutoCAD SHX Text
50
AutoCAD SHX Text
50
AutoCAD SHX Text
4*
AutoCAD SHX Text
J04
AutoCAD SHX Text
LH
AutoCAD SHX Text
41'-0"
AutoCAD SHX Text
STANDARD
AutoCAD SHX Text
32
AutoCAD SHX Text
0
AutoCAD SHX Text
0
AutoCAD SHX Text
174
AutoCAD SHX Text
100
AutoCAD SHX Text
268
AutoCAD SHX Text
451
AutoCAD SHX Text
19
AutoCAD SHX Text
357
AutoCAD SHX Text
10
AutoCAD SHX Text
*
AutoCAD SHX Text
*
AutoCAD SHX Text
*
AutoCAD SHX Text
*
AutoCAD SHX Text
50
AutoCAD SHX Text
50
AutoCAD SHX Text
4*
AutoCAD SHX Text
J05
AutoCAD SHX Text
LH
AutoCAD SHX Text
41'-0"
AutoCAD SHX Text
STANDARD
AutoCAD SHX Text
32
AutoCAD SHX Text
0
AutoCAD SHX Text
0
AutoCAD SHX Text
210
AutoCAD SHX Text
100
AutoCAD SHX Text
261
AutoCAD SHX Text
439
AutoCAD SHX Text
19
AutoCAD SHX Text
271
AutoCAD SHX Text
10
AutoCAD SHX Text
*
AutoCAD SHX Text
*
AutoCAD SHX Text
*
AutoCAD SHX Text
*
AutoCAD SHX Text
50
AutoCAD SHX Text
50
AutoCAD SHX Text
4*
AutoCAD SHX Text
J06
AutoCAD SHX Text
LH
AutoCAD SHX Text
41'-0"
AutoCAD SHX Text
STANDARD
AutoCAD SHX Text
32
AutoCAD SHX Text
0
AutoCAD SHX Text
0
AutoCAD SHX Text
160
AutoCAD SHX Text
100
AutoCAD SHX Text
268
AutoCAD SHX Text
451
AutoCAD SHX Text
19
AutoCAD SHX Text
278
AutoCAD SHX Text
10
AutoCAD SHX Text
*
AutoCAD SHX Text
*
AutoCAD SHX Text
*
AutoCAD SHX Text
*
AutoCAD SHX Text
50
AutoCAD SHX Text
50
AutoCAD SHX Text
4*
AutoCAD SHX Text
J07
AutoCAD SHX Text
LH
AutoCAD SHX Text
41'-0"
AutoCAD SHX Text
STANDARD
AutoCAD SHX Text
32
AutoCAD SHX Text
0
AutoCAD SHX Text
0
AutoCAD SHX Text
160
AutoCAD SHX Text
100
AutoCAD SHX Text
251
AutoCAD SHX Text
227
AutoCAD SHX Text
19
AutoCAD SHX Text
260
AutoCAD SHX Text
10
AutoCAD SHX Text
50
AutoCAD SHX Text
50
AutoCAD SHX Text
J08
AutoCAD SHX Text
LH
AutoCAD SHX Text
33'-11"
AutoCAD SHX Text
STANDARD
AutoCAD SHX Text
32
AutoCAD SHX Text
0
AutoCAD SHX Text
0
AutoCAD SHX Text
160
AutoCAD SHX Text
100
AutoCAD SHX Text
590
AutoCAD SHX Text
50
AutoCAD SHX Text
50
AutoCAD SHX Text
J09
AutoCAD SHX Text
LH
AutoCAD SHX Text
33'-11"
AutoCAD SHX Text
STANDARD
AutoCAD SHX Text
32
AutoCAD SHX Text
0
AutoCAD SHX Text
0
AutoCAD SHX Text
160
AutoCAD SHX Text
100
AutoCAD SHX Text
505
AutoCAD SHX Text
50
AutoCAD SHX Text
50
AutoCAD SHX Text
J10
AutoCAD SHX Text
LH
AutoCAD SHX Text
33'-11"
AutoCAD SHX Text
STANDARD
AutoCAD SHX Text
32
AutoCAD SHX Text
0
AutoCAD SHX Text
0
AutoCAD SHX Text
160
AutoCAD SHX Text
100
AutoCAD SHX Text
420
AutoCAD SHX Text
50
AutoCAD SHX Text
50
AutoCAD SHX Text
J11
AutoCAD SHX Text
LH
AutoCAD SHX Text
41'-0"
AutoCAD SHX Text
STANDARD
AutoCAD SHX Text
32
AutoCAD SHX Text
0
AutoCAD SHX Text
0
AutoCAD SHX Text
157
AutoCAD SHX Text
100
AutoCAD SHX Text
135
AutoCAD SHX Text
227
AutoCAD SHX Text
19
AutoCAD SHX Text
190
AutoCAD SHX Text
10
AutoCAD SHX Text
*
AutoCAD SHX Text
*
AutoCAD SHX Text
*
AutoCAD SHX Text
*
AutoCAD SHX Text
50
AutoCAD SHX Text
50
AutoCAD SHX Text
2, 4*
AutoCAD SHX Text
J12
AutoCAD SHX Text
LH
AutoCAD SHX Text
41'-0"
AutoCAD SHX Text
STANDARD
AutoCAD SHX Text
32
AutoCAD SHX Text
0
AutoCAD SHX Text
0
AutoCAD SHX Text
180
AutoCAD SHX Text
100
AutoCAD SHX Text
268
AutoCAD SHX Text
450
AutoCAD SHX Text
19
AutoCAD SHX Text
428
AutoCAD SHX Text
10
AutoCAD SHX Text
*
AutoCAD SHX Text
*
AutoCAD SHX Text
*
AutoCAD SHX Text
*
AutoCAD SHX Text
16
AutoCAD SHX Text
50
AutoCAD SHX Text
50
AutoCAD SHX Text
4*
AutoCAD SHX Text
J13
AutoCAD SHX Text
LH
AutoCAD SHX Text
J14
AutoCAD SHX Text
LH
AutoCAD SHX Text
J15
AutoCAD SHX Text
LH
AutoCAD SHX Text
J16
AutoCAD SHX Text
LH
AutoCAD SHX Text
J17
AutoCAD SHX Text
LH
AutoCAD SHX Text
J18
AutoCAD SHX Text
LH
AutoCAD SHX Text
J19
AutoCAD SHX Text
LH
AutoCAD SHX Text
J20
AutoCAD SHX Text
LH
AutoCAD SHX Text
NOTES THIS TABLE:
AutoCAD SHX Text
1
AutoCAD SHX Text
TOP CHORD EXTENSION
AutoCAD SHX Text
2
AutoCAD SHX Text
BOTTOM CHORD EXTENSION
AutoCAD SHX Text
3
AutoCAD SHX Text
BEARING @ MASONRY W/ SLOPED SEAT
AutoCAD SHX Text
4
AutoCAD SHX Text
COORDINATE W/ MECHANICAL VENDOR (*)
AutoCAD SHX Text
5
AutoCAD SHX Text
MAX = L/600
AutoCAD SHX Text
6
AutoCAD SHX Text
7
AutoCAD SHX Text
8
AutoCAD SHX Text
9
AutoCAD SHX Text
10
Page 15: THE DOCUMENT AND THE DESIGNS INCORPORATED HEREIN … · 2018-04-24 · system at the construction stages indicated in the structural observation table and at completion of the structural

11 2"

1" 24" 16 GA (54 MIL) 4" DEEP LEGDEFLECTION TRACKSTUDS PER PLAN

TYP CORNER SECTION

TYP INTERSECTION SECTION

TRACK TO MATCHSTUD GAUGE TYPICAL TRACK

#10 SNS AT 30" OCMETAL STUD TO METALSTUD

TYPICAL METAL STUD

TYPICAL TRACK

TYPICAL METAL STUD

#10 SNS AT 30" OCMETAL STUD TO METALSTUD

SECTION @ BUILT-UP JAMB

CONTINUOUSBUILT-UP JAMBSTUDS PERSCHEDULE

#10 SD SCREWS @12" OC

NOTES:1. LATERAL BRIDGING FOR STEEL STUDS IS REQUIRED WHEN WALL BOARD, INSTALLED PER OSSC CHAPTER 25, DOES NOT CONTINUE FULL HEIGHT ON BOTH SIDES. BRIDGING SHALL BE INSTALLED PER THIS DETAIL ON WALL FACES WITHOUT SHEATHING.2. COMPLY WITH STUD MFR'S ICBO APPROVED DETAILS IF MORE RESTRICTIVE.3. PROVIDE CLOSURE TRACK WHERE JAMB TERMINATES @ SILL OTHER LOCATIONS

12"Ø x 4" SIMPSON TITEN HD @

36" OC & 6" FROM CORNERS &END OF TRACK SECTION CONC SLAB

600MT16 W/ #10 SMSTO EACH FLANGE OF STUD

STUD PER PLAN

#10 SCREWS@ 12" OC

TRACK, MATCHSTUDWALL GA COPEWEB EA END AS REQ'D

METAL STUD @16" OC

HEADER STUD SECTIONPER SCHEDULE

SECTION @ HEADER

SECTION @ SILL

OPENING > 8'-0"SECTION @ SILL

#10 SCREWS @12" OC

WT TRACK

#10 SCREW

CLIP JAMB STUD EACHEND

#10 SD

TRACK MATCH STUDWALLGAGE - COPE WEB EA.END @ JAMB STUD

METAL STUD @ 16" O.C.

L2x2x16 GA x 3" CLIP 2/ (2)#10 SCREWS EACH LEG TYP

OPENING PER ARCH 10'-0" MAX

NO SILL WHERE OPENINGEXTENDS TO FLOOR(SIM CONDITION)

METAL STUD @16" OC

DOUBLE STUDFULL HEIGHT

(4) - #10 SCREWS EA SIDE(COPE HEADER FLANGES)

PER ARCH

S7.56

S7.58

NOTES:LOOSE LINTEL TO HAVE 8" BEARING EACH END FOR OPENINGS >3'-4", 4" MIN OPENINGS < 3'-4"

ELEVATION

4"1"

1"

6"

NOTES:PRE-DRILL HOLES IN 3

16"P FOR #12 SMS

CONC SLAB

3/16" BEN T PLATE EACHSIDE W/ (4)-#12 SIMS TOJAMB

4"

4"

1"

1"

TYP TRACK W/#10 SMS TOJAMB

OMIT TRACK AT DOOROPENING THIS SIDE

BUILT-UP JAMB STUD

OMIT BENT PLATE ANDANCHOR AT DOOROPENINGS AND ATJAMBS FOR WALLOPENINGS LESS THAN8'-0"

3/4"

WALL OPENINGBOT 6" OF JAMB (OMITFOR OPENINGS < 8'-0")

NOTES:1. AT JAMB STUDS FOR OPENINGS 8'-0" USE

EACH SIDE AT JAMB STUD2. INSTALL SCREWS IN SLOTS TO ALL FOR DEFLECTION

STUD PER PLAN

SIMPSON SCB 47.5

STUD PER PLAN

4"

DOWN TURNED OPTION WHERE REQ'D - SAD

© 2017 JOHNSON BRODERICK ENGINEERING. No part of this document can be reproduced without the written permission from JBE, [ 325 WEST 13TH AVENUE EUGENE OREGON, 97401. (541)338-9488 or fax (541)338-9483 ]

Proje

ct:

THE DOCUMENT AND THE DESIGNS

INCORPORATED HEREIN ARE THE

PROPERTY OF JOHNSON BRODERICK

ENGINEERING, LLC, AND IS NOT TO BE

USED, IN WHOLE OR PART, FOR ANY

OTHER PROJECT WITHOUT THE

WRITTEN AUTHORIZATION FROM THE

PRINCIPALS OF JOHNSON BRODERICK

ENGINEERING

JBE

JOHN

SON

BROD

ERIC

KEN

GINE

ERIN

GC

iv

il an

d S

tru

ctu

ral E

ng

in

eers

325 W

. 13th

Ave

Euge

ne, O

r 974

01-3

402

Tel (5

41) 3

38-9

488

Fax (

541)

338-

9483

www.

JBE.

US.co

m

Project No:

Drawn By:

Sheet title:

Checked By:

Date:

Date

Revis

ions

Symb

olBy

17095.01

JW

AMB

S7.5

CONS

TRUC

TION

SET

4/20/2

018JW

4/20/2018

COLD-FORMDETAILS

KVAL

ADD

ITIO

NS &

ALT

ERAT

IONS

4575

BLA

NTON

ROA

DEU

GENE

, OR

9740

5

S7.310 NOT USED

NOT TO SCALE

S7.514 NOT USED

S7.515 NOT USED

S7.53 NOT USED

S7.55 DEFTLECTION HEAD

1" = 1'-0"

S7.56 NOT USED

S7.57 NOT USED

S7.56 METAL STUD JAMB

1" = 1'-0"

S7.55 METAL STUD WALL FRAMING

1" = 1'-0"

S7.54 MTL STUD CONNECTION TO FOUNDATION

1"=1'-0"S7.58 METAL STUD WALL HEADER

1" = 1'-0"

S7.59 METAL STUD CAP

1" = 1'-0"S7.513 METAL STUD HEADER AND JAMB

S7.511 TYPICAL CONNECTION @ JAMB SECTION

S7.512 METAL STUD WALL CONNECTION W/ W BEAM

\\JBE

-06\J

BE -

Proje

cts\17

095.x

x - S

ande

rs De

sign\1

7095

.01 -

4575

Blan

ton R

oad\D

rawi

ngs\C

ad\C

ONST

SET

4-20

-201

8\170

95.01

- KV

AL A

dditio

n - S

7 SER

IES.

dwg,

4/20/2

018 3

:01:35

PM

AutoCAD SHX Text
1/8
Page 16: THE DOCUMENT AND THE DESIGNS INCORPORATED HEREIN … · 2018-04-24 · system at the construction stages indicated in the structural observation table and at completion of the structural

12" CMU SOLID GROUTED,CUT UNIT ENDS FOR

CONTINUOUS FLOW OF GROUT

#5 CORNERBAR EA HORIZ TYP

30"30"

(2) #5 VERT @ 16" OCLAP @ FOOTINGSMATCH SPACING

(2) #5 VERT1ST 4 CELLS@ CORNER

(4) - #5 VERTEA SIDE OF JOINT

34"Ø x 24" SMOOTH

GREASED ROD @EA HORIZ BARTYP EA MAT

HORIZ REINF STOPS SEALANT & BACKERROD EA FACE

TYP VERT REINF(2) #5 VERT @ WALL ENDSAND WINDOW JAMBS(4 CELLS)

S8.06

SEE SPECIFIC DETAILSFOR BOLT SIZE ANDSPACING

HOOK DIMS

2d

1" M

IN A

LLAR

OUND

BOL

T

PROVIDE PLUGOR FILLW/ GROUT

(2) #4 x 4'-0" LONG OR HORIZWALL REINF WHERE BOLTSOCCUR AT BOND BEAMBARSHALL BE CONT

(2) #5 CONT @ CHORDS

MASONRY. 2. THE ABOVE IS MINIMUM REINFORCING FOR ALL CONCRETE

REMARKSVERT.HORIZ.(INCHES)

1. CONTINUOUS INSPECTION REQUIRED

3. ALL CELLS SHALL BE GROUTED SOLID.

NOTES:

12" DOUBLE MAT#5 @ 16"

CMU WALL REINFORCING SCHEDULE

#5 @ 16"

BAR SIZE AND SPACINGTHICKNESS

WALLEACH MAT

STD 90° HOOKTOP & BOT

TOP OF WALL

LINTEL REINF

#5 TYP

(4) #5 TOP & BOT

SMOOTH DOWEL

38" JOINT FULL - HEIGHT OF WALL

NO MORTAR SEE ARCHITECTURALFOR SEALANT

FOR LOCATIONSEE ARCHITECTURAL DWGS

ELEVATION

(2) #5 VERT BAR

TERMINATE HORIZSTEEL @ JOINTS

NOTES:LOCATION OF CONTROL JOINTS1. @ 40'-0" MAX2. @ CHANGES IN ALL HEIGHT

S8.02

TO SOGELEV. 97.00'

ELEV. 95.67'TOC

1'-0"

NOTE:REFER TO ARCH. FOR CAPILLARY BREAKBETWEEN CMU AND CONCRETE

FACE OF MASONRY INSULATION SAD

#5 @ 18" OCALT HOOKS #5 @ 18" OC EW

#5 @ 12" OC(3) #5 CONT

(2) #5 16" OC

4'-0" LAP

TO CMU @ GRID 0.5AELEV. 117.00'

TO SOGELEV. 97.00'

ELEV. 95.67'TOC

(2) #5 CONTTYP

#5 @ 16" OCEW EF TYP

FACE OF MASONRY

(2) #5 16" OC

NOTE:REFER TO ARCH. FOR CAPILLARY BREAKBETWEEN CMU AND CONCRETE

TO CMU @ GRID BELEV. 119.67'

INSULATION SAD

NOTE:ROOF STRUCTURE NOTSHOWN FOR CLARITY

12"x11"x15" A36CAP ROOF DECK

PER PLAN

2'-0"

3'-0"

REF

2'-0"2'-10" REF

OPEN WEB STEELJOIST PER PLAN

HSS 4x4x1/4

HSS 4x4x1/4

12"x6" A325 BOLT, N, W

34"x10" J-BOLT @ 34"

OC ANCHOR TYP

FACE OF MASONRY

38"x3"x4" A36

38"x10"xCONT CAP

4'-578" REF

HSS 4x4x1/4x4" LGSHIM AS REQ'D

L 5x3x3/8

OPEN WEB STEELJOIST PER PLAN

OPEN WEB STEELJOIST PER PLAN

BOLTS @ 36" OC

2'-6"

ROOF DECKPER PLAN

OPEN WEB STEELJOIST PER PLAN

12"x11"x15" A36

TYP

34"x10" J-BOLT @ 24"

OC ANCHOR TYP

FACE OF MASONRY

2'-6"

12"x11"x15" A36

TYP

34"x10" J-BOLT @ 24"

OC ANCHOR TYP

ROOF DECKPER PLAN

OPEN WEB STEELJOIST PER PLAN

FACE OF MASONRY

ROOF DECKPER PLAN

OPEN WEB STEELJOIST PER PLAN

SEE SPECIFIC DETAILSFOR BOLT SIZE ANDSPACING

FACE OF MASONRY

W18x50

58"Ø @ 32" OC

L 4"X4"X14" CONT

W/ LONG SLOTTED HOLE

B

C STEELL

ROOF DECKPER PLAN

SEE SPECIFIC DETAILSFOR BOLT SIZE ANDSPACING

FACE OF MASONRY

W16x26

58"Ø @ 32" OC

L 4"X4"X14" CONT

W/ LONG SLOTTED HOLE

2

C STEELL

S8.01 CMU WALL CORNER

1" = 1'-0"

© 2017 JOHNSON BRODERICK ENGINEERING. No part of this document can be reproduced without the written permission from JBE, [ 325 WEST 13TH AVENUE EUGENE OREGON, 97401. (541)338-9488 or fax (541)338-9483 ]

Proje

ct:

THE DOCUMENT AND THE DESIGNS

INCORPORATED HEREIN ARE THE

PROPERTY OF JOHNSON BRODERICK

ENGINEERING, LLC, AND IS NOT TO BE

USED, IN WHOLE OR PART, FOR ANY

OTHER PROJECT WITHOUT THE

WRITTEN AUTHORIZATION FROM THE

PRINCIPALS OF JOHNSON BRODERICK

ENGINEERING

JBE

JOHN

SON

BROD

ERIC

KEN

GINE

ERIN

GC

iv

il an

d S

tru

ctu

ral E

ng

in

eers

325 W

. 13th

Ave

Euge

ne, O

r 974

01-3

402

Tel (5

41) 3

38-9

488

Fax (

541)

338-

9483

www.

JBE.

US.co

m

Project No:

Drawn By:

Sheet title:

Checked By:

Date:

Date

Revis

ions

Symb

olBy

17095.01

JW

AMB

S8.0

CONS

TRUC

TION

SET

4/20/2

018WR

S

4/20/2018

CMU DETAILS

KVAL

ADD

ITIO

NS &

ALT

ERAT

IONS

4575

BLA

NTON

ROA

DEU

GENE

, OR

9740

5

S8.02 CMU WALL DETAIL

3/4" = 1'-0"

S8.03 TYP ANCHOR BOLT IN WALL

3/4" = 1'-0"

S8.04 CMU WALL REINFORCING

3/4" = 1'-0"

S8.06 CMU CONTROL JOINT - ELEVATION

3/4" = 1'-0"

S8.07 CMU FOOTING

S8.015 DRAG @ GRID B

3/4" = 1'-0"

S8.05 MIN REINFORCEMENT @ HEADERS

3/4" = 1'-0"

S8.09 NOT USED

S8.011 CMU WALL, JOIST DETAIL

3/4" = 1'-0"

S8.010 CMU ELEVATION

NTS

S8.014 DRAG @ GRID 2

1" = 1'-0"

S8.013 CMU WALL, JOIST DETAIL

3/4" = 1'-0"

S8.012 CMU WALL, JOIST DETAIL

3/4" = 1'-0"

\\JBE

-06\J

BE -

Proje

cts\17

095.x

x - S

ande

rs De

sign\1

7095

.01 -

4575

Blan

ton R

oad\D

rawi

ngs\C

ad\C

ONST

SET

4-20

-201

8\170

95.01

- KV

AL A

dditio

n - S

8 SER

IES.

dwg,

4/20/2

018 3

:02:55

PM

AutoCAD SHX Text
ESTCODE
AutoCAD SHX Text
ESTCODE
AutoCAD SHX Text
ESTCODE
AutoCAD SHX Text
ESTCODE
AutoCAD SHX Text
ESTCODE
AutoCAD SHX Text
ESTCODE
AutoCAD SHX Text
ESTCODE
AutoCAD SHX Text
ESTCODE
AutoCAD SHX Text
ESTCODE
AutoCAD SHX Text
1/4
AutoCAD SHX Text
TYP
AutoCAD SHX Text
1/4
AutoCAD SHX Text
TYP
AutoCAD SHX Text
1/4
AutoCAD SHX Text
1/4
AutoCAD SHX Text
TYP
AutoCAD SHX Text
1/4
AutoCAD SHX Text
TYP
AutoCAD SHX Text
1/4
AutoCAD SHX Text
TYP