the city of winnipeg · spk fss rrelocated location deddedicated circuit ocon counter fire alarm...

1
1539 WAVERLEY STREET G G G CONCRETE CONCRETE TRAILER SHIPPING CONTAINER CSTE M.TOWER OR PAD CONCRETE DOOR 30 DOOR 30 LADDER D CCT D AC CCT D AC CCT D AC CCT D DSW CCT R T AC CCT AC CCT CCT CCT ? CCT ? CCT ? CCT ? CCT ? CCT ? CCT ? CCT ? CCT ? CCT ? CCT ? CCT ? CCT ? CCT ? CCT ? CCT ? CCT ? CCT ? CCT ? CCT ? CCT ? CCT ? CCT ? CCT D CCT D CCT ? FT HWH R D CCT UH-5 UH-4 D T FT EXIT CCT KP KS FP CCT 80"AFF CCT CCT FB D T D DSW EF-3 D CCT ? D CCT ? D CCT ? D DSW EF-5 R CCT D CCT FT Winnipeg DRAWING SHEET SIZE: A1 (841mm x 594mm) PLOT 1:1 DTA 1539 WAVERLEY STREET 2018018EV0.dwg 2018.12.06 - 2018-018 1539 WAVERLEY STREET 2018.12.06 DTA E1 2018-018 AS SHOWN ELECTRICAL DEMOLITION AND RENOVATION PARTIAL MAIN FLOOR PLAN STORAGE GARAGE RENOVATIONS TO ENLARGE PARKS VEHICLE PUBLIC WORKS SOUTH YARD PARTIAL MAIN FLOOR PLAN - DEMOLITION REFLECTED CEILING PLAN ALSO SHOWN FOR CLARITY SCALE: 1/8 = 1'-0" KEY PLAN SCALE: N.T.S. THESE DRAWINGS SHALL NOT BE SCALED. CONSULT WITH CLIENT AND DESIGNER ON ANY CONCERNS. ALSO REFER TO ELECTRICAL SPECIFICATIONS. SUBMISSION OF SITE MARK-UPS, AS-BUILTS, OPERATING & MAINTENANCE MANUALS AND OTHER SUPPORTING DOCUMENTS TO CLIENT ARE MANDATORY AT THE COMPLETION OF THIS PROJECT. THE CONTRACTOR SHALL VISIT THE SITE AND ENSURE ALL DIMENSIONS, DATUM, AND DETAILED INFORMATION SHOWN ARE CORRECT. THE CONTRACTOR IS TO REVIEW AND COORDINATE ALL ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL OPENINGS THROUGH FLOORS, WALLS, AND CEILINGS FOR DUCTS, PIPES & ELECTRICAL RISERS AND ALL OPENINGS NOT SHOWN ON DRAWINGS. ALL OPENINGS THROUGH FIRE ASSEMBLIES INCLUDING FLOORS AND CEILINGS ARE TO BE FIRE STOPPED AND SEALED WITH ULC APPROVED FIRE STOPPING TO MAINTAIN THE INTEGRITY OF THE FIRE SEPARATION, AND PROVIDE A SMOKE-TIGHT BARRIER. ALL PRODUCTS AND MATERIALS TO BE USED AND INSTALLED SHALL CONFORM WITH MANUFACTURER'S SPECIFICATIONS, APPLICABLE CODES AND AUTHORITY HAVING JURISDICTION. THE CONTRACTOR SHALL BE RESPONSIBLE TO PATCH AND MAKE GOOD ALL EXISTING CONSTRUCTION AFFECTED BY THE REMOVAL OF ALL ITEMS FORMING PART OF THE RENOVATION WORK. ALL ABANDONED (KNOWN & UNKNOWN) ELECTRICAL FIXTURES, COMPONENTS, RECEPTACLES & DATA CABLING SHALL BE REMOVED BACK TO SOURCE & TERMINATED AS PER APPLICABLE CODES. RECONNECT & TEST ALL FIRE PREVENTION EQUIPMENT. WARNING: ASBESTOS MAYBE PRESENT BEHIND WALLS, CEILING SPACE & FLOORS. IF ASBESTOS & ANY HAZARDOUS MATERIAL IS FOUND, STOP WORK IMMEDIATELY & CONTACT CITY OF WINNIPEG, CENTRAL CONTROLS, PH: 204-986-2351. 0 DTA 2018 .??.?? ISSUED FOR CONSTRUCTION 2 POWER AND SYSTEMS DEMOLITION NOTES: " " ALSO SEE NOTES & SPECIFICATIONS. REFER TO APPLICABLE RENOVATION DRAWING FOR RELOCATED COMPONENTS. ALL ABANDONED CABLES TO BE REMOVED AS REQUIRED BY LATEST CANADIAN ELECTRICAL CODE. DO NOT DISTURB OR DISCONNECT ANY WIRING & CABLING IN AREA OF WORK REQUIRED FOR OTHER AREAS. 1. REMOVE ALL COMPONENTS WITH DESIGNATION "D" BACK TO SOURCE , UNLESS OTHERWISE NOTED. 2. REMOVE & DISCONNECT ALL MECHANICAL EQUIPMENT (CONDUIT, WIRING, SUPPORTS, ELECTRICAL BOXES, STARTER, DISCONNECT, TIMER, RESET) BACK TO SOURCE - INCLUDING INTERLOCKS TO ASSOCIATE EQUIPMENTS. 3. EXISTING CEILING LUMINARIES TO REMAIN, UNLESS OTHERWISE NOTED. 4. EXISTING LIGHT SWITCHES TO REMAIN. EXCEPT WALL MOUNTED LIGHT SWITCHES DESIGNATED FOR WALL DEMOLITION & BRANCH CIRCUIT CONNECTED TO NON-DEMOLITION AREA - CIRCUITS TO REMAIN & LIGHT SWITCH DEVICE BOX TO BE TEMPORARY SUPPORTED. 5. REMOVE PAINT BOOTH LUMINAIRES & LIGHT SWITCH BACK TO SOURCE. 6. RELOCATE ELECTRIC HOT WATER HEATER CIRCUIT TO NEW LOCATION, SEE MECHANICAL DRAWING. 7. REMOVE ALL ELECTRICAL SURFACE MOUNTED COMPONENTS ON WALL BACK TO SOURCE IN AREA SHOWN. THERMOSTATS TO BE RELOCATED AS PER MECHANICAL DRAWINGS. 8. ALL FIRE DETECTION/PREVENTION DEVICES TO REMAIN (E.G., CEILING HEAT DETECTORS, SMOKE DETECTORS, FIRE ALARM PULL STATIONS, COMBINATION HORN STROBES, EMERGENCY LIGHTING). "X" 2 5 6 7 4 7 PNL "X" ELECTRICAL PANEL VOICE (PHONE) PORT: CENTREX LAND LINE T THERMOSTAT SPK SPEAKER ELECTRICAL LEGEND DESCRIPTION TYPE DUPLEX RECEPTACLE FIRE ALARM MANUAL PULL STATION LIGHT SWITCH, SINGLE POLE HEIGHT IN INCHES ABOVE FINISH FLOOR TO CENTERLINE OF DEVICE ABBREVIATIONS DESCRIPTION DSW CIRCUIT, CCT: C=PANEL "B"; CT= CIRCUIT "1" (B1) CCT DISCONNECT SWITCH ABOVE FINISH FLOOR AFF AMPERE, AMPACITY A HVAC EXISTING OR "NO DESIGNATION" E HEATING, VENTILATING AND AIR CONDITIONING DEMOLITION , REMOVE BACK TO SOURCE D DRAWING DWG MD METER M MOTION DETECTOR JUNCTION BOX JB HERTZ HZ GROUND FAULT CIRCUIT INTERRUPTER GFCI NTS NOT TO SCALE TYP. PANEL PNL TYPICAL OCCUPANCY SENSOR OS WATT W VOLT V RECEPTACLE RECPT. N NEW SWITCH SW HEATER HTR FB JB KP H MD +XX DSW DISCONNECT SWITCH JUNCTION BOX FP FIRE ALARM BELL FT HEAT DETECTOR, CEILING RECESSED DATA PORT KEY PAD/DISPLAY - SECURITY HORN - SECURITY MOTION DETECTOR- SECURITY FT HEAT DETECTOR, CEILING SURFACE MOUNT SPK PUBLIC ADDRESS SPEAKER ABOVE COUNTER AC DUPLEX RECEPTACLE WITH (2) 2A USB 2.2 & 3.0 CAPABLE USB SPK FSS RELOCATED LOCATION R DEDICATED CIRCUIT DED ON COUNTER OC FIRE ALARM STROBE SIREN FLOOR PEDESTAL DATA PORT SPEAKER SPEAKER VOLUME CONTROLLER SPK SPEAKER TO BE DETERMINED TBD ACOUSTIC CEILING TILE ACT DISHWASHER D/W 2-GANG DUPLEX RECEPTACLE 1,2 N.I.C. NOT IN CONTRACT GF GROUND FAULT CIRCUIT INTERRUPTER DUPLEX RECEPTACLE ON CENTER O/C CEILING CLNG JB BELOW FINISH CEILING BFC 3 TYP. 1 2 1 8 8 8 8 AREA OF WORK 8

Upload: others

Post on 04-Feb-2020

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: THE CITY OF WINNIPEG · spk fss rrelocated location deddedicated circuit ocon counter fire alarm strobe siren floor pedestal data port speaker speaker volume controller spkspeaker

1539 WAVERLEY STREET

G G G

CONCRETE

CONCRETE

TRAIL

ER

SHIPP

INGCO

NTAIN

ER

CSTE

COMM.TOWERANCHOR PAD

CONCRETE

DOOR 30

DOOR 30

LADDER

DCCT

DAC

CCT

DAC

CCT

DAC

CCT

DDSWCCTR T

ACCCT

ACCCT

CCT

CCT ?

CCT ? CCT ? CCT ? CCT ?

CCT

?

CCT ? CCT ? CCT ?

CCT ?CCT ?CCT ?

CCT ? CCT ? CCT ? CCT ?

CCT ? CCT ?

CCT ? CCT ? CCT ?

CCT

?

CCT

?

CCT

DCCT

DCCT?

FT

HWHR

D CCT

UH-5

UH-4

D T

FT

EXIT CCT

KPKSFP

CCT

80"AFFCCT

CCT FB

DT

DDSW EF-3

DCCT?

DCCT?

DCCT?

DDSWEF-5

RCCT

DCCT

FT

Winnipeg

DRAWING SHEET SIZE: A1 (841mm x 594mm) PLOT 1:1

DTA

1539 WAVERLEY STREET

201801

8EV0

.dwg

2018.1

2.06

-201

8-018

1539 W

AVER

LEY S

TREE

T

2018.12.06

DTA

E12018-018AS SHOWN

ELECTRICAL DEMOLITION AND RENOVATIONPARTIAL MAIN FLOOR PLAN

STORAGE GARAGERENOVATIONS TO ENLARGE PARKS VEHICLEPUBLIC WORKS SOUTH YARD

PARTIAL MAIN FLOOR PLAN - DEMOLITIONREFLECTED CEILING PLAN ALSO SHOWN FOR CLARITYSCALE: 1/8 = 1'-0"

KEY PLANSCALE: N.T.S.

THESE DRAWINGS SHALL NOT BE SCALED. CONSULT WITH CLIENT AND DESIGNER ON ANYCONCERNS.

ALSO REFER TO ELECTRICAL SPECIFICATIONS.

SUBMISSION OF SITE MARK-UPS, AS-BUILTS, OPERATING & MAINTENANCE MANUALS AND OTHERSUPPORTING DOCUMENTS TO CLIENT ARE MANDATORY AT THE COMPLETION OF THIS PROJECT.

THE CONTRACTOR SHALL VISIT THE SITE AND ENSURE ALL DIMENSIONS, DATUM, AND DETAILEDINFORMATION SHOWN ARE CORRECT.

THE CONTRACTOR IS TO REVIEW AND COORDINATE ALL ARCHITECTURAL, MECHANICAL ANDELECTRICAL DRAWINGS FOR ADDITIONAL OPENINGS THROUGH FLOORS, WALLS, AND CEILINGSFOR DUCTS, PIPES & ELECTRICAL RISERS AND ALL OPENINGS NOT SHOWN ON DRAWINGS.

ALL OPENINGS THROUGH FIRE ASSEMBLIES INCLUDING FLOORS AND CEILINGS ARE TO BE FIRESTOPPED AND SEALED WITH ULC APPROVED FIRE STOPPING TO MAINTAIN THE INTEGRITY OFTHE FIRE SEPARATION, AND PROVIDE A SMOKE-TIGHT BARRIER.

ALL PRODUCTS AND MATERIALS TO BE USED AND INSTALLED SHALL CONFORM WITHMANUFACTURER'S SPECIFICATIONS, APPLICABLE CODES AND AUTHORITY HAVINGJURISDICTION.

THE CONTRACTOR SHALL BE RESPONSIBLE TO PATCH AND MAKE GOOD ALL EXISTINGCONSTRUCTION AFFECTED BY THE REMOVAL OF ALL ITEMS FORMING PART OF THERENOVATION WORK.

ALL ABANDONED (KNOWN & UNKNOWN) ELECTRICAL FIXTURES, COMPONENTS, RECEPTACLES &DATA CABLING SHALL BE REMOVED BACK TO SOURCE & TERMINATED AS PER APPLICABLECODES.

RECONNECT & TEST ALL FIRE PREVENTION EQUIPMENT.

WARNING:ASBESTOS MAYBE PRESENT BEHIND WALLS, CEILING SPACE & FLOORS.IF ASBESTOS & ANY HAZARDOUS MATERIAL IS FOUND, STOP WORKIMMEDIATELY & CONTACT CITY OF WINNIPEG, CENTRAL CONTROLS, PH:204-986-2351.

0 DTA 2018.??.??ISSUED FOR CONSTRUCTION

2POWER AND SYSTEMS DEMOLITION NOTES: " "ALSO SEE NOTES & SPECIFICATIONS.REFER TO APPLICABLE RENOVATION DRAWING FOR RELOCATED COMPONENTS.ALL ABANDONED CABLES TO BE REMOVED AS REQUIRED BY LATEST CANADIAN ELECTRICAL CODE.DO NOT DISTURB OR DISCONNECT ANY WIRING & CABLING IN AREA OF WORK REQUIRED FOR OTHER AREAS.

1. REMOVE ALL COMPONENTS WITH DESIGNATION "D" BACK TO SOURCE , UNLESS OTHERWISE NOTED.

2. REMOVE & DISCONNECT ALL MECHANICAL EQUIPMENT (CONDUIT, WIRING, SUPPORTS, ELECTRICAL BOXES, STARTER,DISCONNECT, TIMER, RESET) BACK TO SOURCE - INCLUDING INTERLOCKS TO ASSOCIATE EQUIPMENTS.

3. EXISTING CEILING LUMINARIES TO REMAIN, UNLESS OTHERWISE NOTED.

4. EXISTING LIGHT SWITCHES TO REMAIN. EXCEPT WALL MOUNTED LIGHT SWITCHES DESIGNATED FOR WALL DEMOLITION &BRANCH CIRCUIT CONNECTED TO NON-DEMOLITION AREA - CIRCUITS TO REMAIN & LIGHT SWITCH DEVICE BOX TO BETEMPORARY SUPPORTED.

5. REMOVE PAINT BOOTH LUMINAIRES & LIGHT SWITCH BACK TO SOURCE.

6. RELOCATE ELECTRIC HOT WATER HEATER CIRCUIT TO NEW LOCATION, SEE MECHANICAL DRAWING.

7. REMOVE ALL ELECTRICAL SURFACE MOUNTED COMPONENTS ON WALL BACK TO SOURCE IN AREA SHOWN. THERMOSTATS TO BERELOCATED AS PER MECHANICAL DRAWINGS.

8. ALL FIRE DETECTION/PREVENTION DEVICES TO REMAIN (E.G., CEILING HEAT DETECTORS, SMOKE DETECTORS, FIRE ALARM PULLSTATIONS, COMBINATION HORN STROBES, EMERGENCY LIGHTING).

"X"

2

5

6

7

4

7

PNL "X" ELECTRICAL PANEL

VOICE (PHONE) PORT: CENTREX LAND LINE

T THERMOSTAT

SPK SPEAKER

ELECTRICAL LEGEND

DESCRIPTIONTYPEDUPLEX RECEPTACLE

FIRE ALARM MANUAL PULL STATION

LIGHT SWITCH, SINGLE POLE

HEIGHT IN INCHES ABOVE FINISH FLOOR TO CENTERLINE OF DEVICE

ABBREVIATIONSDESCRIPTION

DSW

CIRCUIT, CCT: C=PANEL "B"; CT= CIRCUIT "1" (B1)CCT

DISCONNECT SWITCH

ABOVE FINISH FLOORAFF

AMPERE, AMPACITYA

HVAC

EXISTING OR "NO DESIGNATION"E

HEATING, VENTILATING AND AIR CONDITIONING

DEMOLITION , REMOVE BACK TO SOURCED

DRAWINGDWG

MDMETERMMOTION DETECTOR

JUNCTION BOXJBHERTZHZ

GROUND FAULT CIRCUIT INTERRUPTERGFCI

NTS NOT TO SCALE

TYP.

PANELPNL

TYPICAL

OCCUPANCY SENSOROS

WATTWVOLTV

RECEPTACLERECPT.

N NEW

SWITCHSW

HEATERHTR

FB

JB

KP

H

MD

+XX

DSW DISCONNECT SWITCHJUNCTION BOX

FP

FIRE ALARM BELL

FT HEAT DETECTOR, CEILING RECESSED

DATA PORT

KEY PAD/DISPLAY - SECURITYHORN - SECURITYMOTION DETECTOR- SECURITY

FT HEAT DETECTOR, CEILING SURFACE MOUNTSPK PUBLIC ADDRESS SPEAKER

ABOVE COUNTERAC

DUPLEX RECEPTACLE WITH (2) 2A USB 2.2 & 3.0 CAPABLEUSB

SPK

FSS

RELOCATED LOCATIONR

DEDICATED CIRCUITDED

ON COUNTEROC

FIRE ALARM STROBE SIREN

FLOOR PEDESTAL DATA PORT

SPEAKERSPEAKER VOLUME CONTROLLER

SPK SPEAKER

TO BE DETERMINEDTBD

ACOUSTIC CEILING TILEACT

DISHWASHERD/W

2-GANG DUPLEX RECEPTACLE1,2

N.I.C. NOT IN CONTRACT

GF GROUND FAULT CIRCUIT INTERRUPTER DUPLEX RECEPTACLE

ON CENTERO/C

CEILINGCLNGJB

BELOW FINISH CEILINGBFC

3TYP.

1

2 1

8

8

8

8

AREA OF WORK

8

AutoCAD SHX Text
s
AutoCAD SHX Text
s
AutoCAD SHX Text
s
AutoCAD SHX Text
s
AutoCAD SHX Text
s
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
DATE
AutoCAD SHX Text
USER APPROVAL
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
DESIGNED
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
THE CITY OF WINNIPEG PLANNING, PROPERTY AND DEVELOPMENT DEPARTMENT MUNICIPAL ACCOMMODATIONS DIVISION 3-65 GARRY STREET, R3C 4K4
AutoCAD SHX Text
SEAL
AutoCAD SHX Text
No.
AutoCAD SHX Text
REVISION/DESCRIPTION
AutoCAD SHX Text
BY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
PROJECT
AutoCAD SHX Text
SHEET TITLE
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
PROJECT No:
AutoCAD SHX Text
SHEET No:
AutoCAD SHX Text
NOTES:
AutoCAD SHX Text
ADDRESS:
AutoCAD SHX Text
PROJECT No:
AutoCAD SHX Text
SHEET TITLE:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
FILE NAME:
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
s