tf1 quick reference installation and cleaning guide

2
TF1 installation and cleaning Quick Reference Guide Lid tightening www.fernox.com For full instructions please refer to TF1 instructions. In the event that the lid of the TF1 has been removed, ensure the lid is fully re-tightened to the correct position (lining up the embossed line mark on both the lid and the inlet/outlet port), using the spanner provided (see diagram). The TF1 unit does not need to be disassembled for installation, cleaning or servicing however if disassembled, replace all appropriate seals for example the lid collar/bleed valve ‘O’ rings, as good practice dictates (spares are provided with product in box). Additional Fernox TF1 Range Seal and ‘O’ ring kit is available: item number 59288. Fast clean for TF1 Compact & TF1 Total Filter – no need to remove lid 30 seconds Close inlet and outlet valves Open outlet and drain valves Close drain valve, replace magnet and open inlet valve Remove magnet 1 2 3 4

Upload: fernox

Post on 27-May-2015

1.504 views

Category:

Documents


4 download

DESCRIPTION

Quick reference guide for installation and cleaning TF1 Compact and TF1 Total Filter. Refer to the TF1 instructions for full instructions.

TRANSCRIPT

Page 1: TF1 Quick Reference Installation and Cleaning Guide

TF1 installation and cleaning

Quick Reference GuideLid tightening

www.fernox.com

For full instructions please refer to TF1 instructions.

In the event that the lid of the TF1 has been removed, ensure the lid is fully re-tightened to the correct position (lining up the embossed line mark on both the lid and the inlet/outlet port), using the spanner provided (see diagram).

The TF1 unit does not need to be disassembled for installation, cleaning or servicing however if disassembled, replace all appropriate seals for example the lid collar/bleed valve ‘O’ rings, as good practice dictates (spares are provided with product in box). Additional Fernox TF1 Range Seal and ‘O’ ring kit is available: item number 59288.

Fast clean for TF1 Compact & TF1 Total Filter – no need to remove lid

30 seconds

Close inlet and outlet valves

Open outlet and drain valves

Close drain valve, replace magnet and open inlet valve

Remove magnet1 2 3 4

Page 2: TF1 Quick Reference Installation and Cleaning Guide

Fernox, Alent plc, Forsyth Road, Sheerwater, Woking, Surrey GU21 5RZ Technical Helpline: +44 (0)870 870 0362 Email: [email protected]

Fernox Total Filter TF1 is UK UK Patent No. GB2448232. Patent Applied For GB1213773.3A

www.fernox.com

Sealed system Open vented system

How to change the orientation for both the TF1 Compact & TF1 Total Filter

Using a flat end screwdriver in the recess shown, gently lever the locking clip into the ‘unlock’ position.

Pull the inlet/outlet port approximately 3 mm away from the body to allow rotation to the required position.

Push the inlet/outlet port back towards the body of the unit to prevent further rotation.

Push the locking clip securely back into the ‘lock’ position.

Flow

Flow Return

Return