test report no. env-pr085361-00 rev. 1test report no. env-pr085361-00 rev. 1 page 1 of 40 this...
TRANSCRIPT
![Page 1: Test Report No. ENV-PR085361-00 Rev. 1Test Report No. ENV-PR085361-00 Rev. 1 Page 1 of 40 This report and the information contained herein represents the results of testing of only](https://reader033.vdocuments.site/reader033/viewer/2022052022/603809ec96d73138631fef18/html5/thumbnails/1.jpg)
Test Report No. ENV-PR085361-00 Rev. 1 Page 1 of 40
This report and the information contained herein represents the results of testing of only those articles/products identified in this document and selected
by the client. The tests were performed to specifications and/or procedures approved by the client. National Technical Systems (“NTS”) makes no
representations expressed or implied that such testing fully demonstrates efficiency, performance, reliability, or any other characteristic of the articles
being tested, or similar products. This report should not be relied upon as an endorsement or certification by NTS of the equipment tested, nor does it
present any statement whatsoever as to the merchantability or fitness of the test article or similar products for a particular purpose. This document shall
not be reproduced except in full without written approval from NTS.
www.nts.com
National Technical Systems Main: 303-776-7249 Environmental & Dynamics Lab Fax: 303-776-7314 1601 Dry Creek Dr. #2000 Longmont, CO 80503
Date: 12 OCTOBER 2018
Customer: Pro V&V, Inc. 700 Boulevard South Suite 102 Huntsville, AL 35802 Purchase Order Number: 2018-010
A. TEST: Thermal, Humidity, Bench Handling, Vibration, and Temperature/Power Variation
B. TEST ITEMS: ClearCast Voting Machine
See page 2 for Test Item Identification
C. SPECIFICATIONS: 1. Quotation Number OP0257934-01 2. ISO 17025:2005
D. RESULTS: This is to certify that the ClearCast Voting Machine was subjected to environmental/dynamic testing according to the above specifications. See Page 2 for Summary of Test Results. The ClearCast Voting Machine was returned to Pro V&V for post-tests and final evaluation. Test data, an equipment list, and photographs are attached.
Greg Gagne, Technical Writer
Bob Polverari, Technical Reviewer
![Page 2: Test Report No. ENV-PR085361-00 Rev. 1Test Report No. ENV-PR085361-00 Rev. 1 Page 1 of 40 This report and the information contained herein represents the results of testing of only](https://reader033.vdocuments.site/reader033/viewer/2022052022/603809ec96d73138631fef18/html5/thumbnails/2.jpg)
Test Report No. ENV-PR085361-00 Rev. 1
2
REVISIONS
Revision Reason for Revision Date
NR
1
Initial Release
Added vibration testing performed.
12 October 2018
16 November 2018
![Page 3: Test Report No. ENV-PR085361-00 Rev. 1Test Report No. ENV-PR085361-00 Rev. 1 Page 1 of 40 This report and the information contained herein represents the results of testing of only](https://reader033.vdocuments.site/reader033/viewer/2022052022/603809ec96d73138631fef18/html5/thumbnails/3.jpg)
Test Report No. ENV-PR085361-00 Rev. 1
3
TEST ITEM IDENTIFICATION
Quantity Sample Description Serial
Numbers
2 ClearCast Voting Machines CASTD002009
CASTD002010
SUMMARY OF TEST RESULTS
Upon completion of testing, the test samples were removed from the test fixture and subjected
to a visual inspection. No anomalies were noted. The Test Samples were returned to Pro V&V.
Humidity Testing
Test was started on 05 September 2018 and completed on 17 September 2018 by subjecting
one (1) UUT to 10-day Humidity Testing in accordance with Quotation Number OP0257934-01
and MIL-STD-810D.
Note: All test pass/fail determination decided by Pro V&V.
Thermal Testing
Testing was started on 17 September 2018 and completed on 19 September 2018 by exposing
the test sample to high and low temperature testing in accordance with Quotation Number
OP0257934-01 and MIL-STD-810D.
High Temperature: The test sample was placed in the chamber and exposed to +60°C (with a
ramp rate from ambient at 5°C per minute) for a 4-hour dwell.
Low Temperature: The test sample was placed in the chamber and exposed to -20°C (with a
ramp rate from ambient at 5°C per minute) for a 4-hour dwell.
Note: All test pass/fail determination decided by Pro V&V.
Bench Handling Test
Testing was started and completed on 20 September 2018 by exposing one (1) UUT to Bench
Handling testing in accordance with Quotation Number OP0257934-01 and MIL-STD-810D.
The test sample was subjected to six (6) drops per corner of UUT from four (4) inches for a total
of twenty-four (24) drops.
Note: All test pass/fail determination decided by Pro V&V.
![Page 4: Test Report No. ENV-PR085361-00 Rev. 1Test Report No. ENV-PR085361-00 Rev. 1 Page 1 of 40 This report and the information contained herein represents the results of testing of only](https://reader033.vdocuments.site/reader033/viewer/2022052022/603809ec96d73138631fef18/html5/thumbnails/4.jpg)
Test Report No. ENV-PR085361-00 Rev. 1
4
Temperature/Power Variation Testing
Testing was started on 24 September 2018 and completed on 27 September 2018 by exposing
two (2) UUT’s to Power Variation testing in accordance with Quotation Number OP0257934-01
and MIL-STD-810D.
The test samples were placed in the chamber and exposed to voltage and temperature
variances with a 4-hour dwell per sequence, noting that the power varies every 4 hours for two
(2) 24 hour cycles, with the temperature varying every 12 hours for two (2) 24 hour cycles. See
Test Log on page 9 for detailed sequences.
Note: All test pass/fail determination decided by Pro V&V.
Vibration Testing
Testing was started and completed on 20 September 2018 by exposing one (1) UUT to
Transportation Vibration Testing in accordance with Quotation Number OP0257934-01 and MIL-
STD-810D.
The test sample was secured to the shaker and the following profiles were run on the
corresponding axes:
Transverse axis: 0.20 gRMS random vibration profile
Longitudinal axis: 0.74 gRMS random vibration profile
Vertical axis: 1.04 gRMS random vibration profile
Note: All test pass/fail determination decided by Pro V&V.
![Page 5: Test Report No. ENV-PR085361-00 Rev. 1Test Report No. ENV-PR085361-00 Rev. 1 Page 1 of 40 This report and the information contained herein represents the results of testing of only](https://reader033.vdocuments.site/reader033/viewer/2022052022/603809ec96d73138631fef18/html5/thumbnails/5.jpg)
Test Report No. ENV-PR085361-00 Rev. 1
5
TEST LOGS
![Page 6: Test Report No. ENV-PR085361-00 Rev. 1Test Report No. ENV-PR085361-00 Rev. 1 Page 1 of 40 This report and the information contained herein represents the results of testing of only](https://reader033.vdocuments.site/reader033/viewer/2022052022/603809ec96d73138631fef18/html5/thumbnails/6.jpg)
Test Report No. ENV-PR085361-00 Rev. 1
6
![Page 7: Test Report No. ENV-PR085361-00 Rev. 1Test Report No. ENV-PR085361-00 Rev. 1 Page 1 of 40 This report and the information contained herein represents the results of testing of only](https://reader033.vdocuments.site/reader033/viewer/2022052022/603809ec96d73138631fef18/html5/thumbnails/7.jpg)
Test Report No. ENV-PR085361-00 Rev. 1
7
![Page 8: Test Report No. ENV-PR085361-00 Rev. 1Test Report No. ENV-PR085361-00 Rev. 1 Page 1 of 40 This report and the information contained herein represents the results of testing of only](https://reader033.vdocuments.site/reader033/viewer/2022052022/603809ec96d73138631fef18/html5/thumbnails/8.jpg)
Test Report No. ENV-PR085361-00 Rev. 1
8
![Page 9: Test Report No. ENV-PR085361-00 Rev. 1Test Report No. ENV-PR085361-00 Rev. 1 Page 1 of 40 This report and the information contained herein represents the results of testing of only](https://reader033.vdocuments.site/reader033/viewer/2022052022/603809ec96d73138631fef18/html5/thumbnails/9.jpg)
Test Report No. ENV-PR085361-00 Rev. 1
9
![Page 10: Test Report No. ENV-PR085361-00 Rev. 1Test Report No. ENV-PR085361-00 Rev. 1 Page 1 of 40 This report and the information contained herein represents the results of testing of only](https://reader033.vdocuments.site/reader033/viewer/2022052022/603809ec96d73138631fef18/html5/thumbnails/10.jpg)
Test Report No. ENV-PR085361-00 Rev. 1
10
Start Date: 9/20/18 End Date: 9/20/18 MJO No:
PR085361
Customer: Pro V&V Test Performed: Transportation
Vibration Test Engineer:
Michael
Nash
Part Name: Clearcast Voting
Machine Serial numbers: CASTD002009
Customer
Witness: N/A
Page of Test Specification: Mil-STD-810D
Temp: 70°
Humidity:
45%
Date Time Axis Plot No. Serial
No. Remarks Initials
9/20/18 0930 Trans Setup UUT on shaker HYD05 in the Transverse-Axis MN
0953 Run 1 Run .20 gRMS random vibration on packaged UUT in
the Transverse-Axis
MN
1055 Long Rotate UUT to the Longitudinal-Axis MN
1103 Run 2 Run .74 gRMS random vibration on packaged UUT in
the Longitudinal-Axis
MN
1205 Vert Changeover to shaker HYD06 in the Vertical-Axis MN
1222 Run 3 Run 1.04 gRMS random vibration on packaged UUT in
the Vertical-Axis
MN
1330 Units were functionally tested and worked to design.
Testing complete.
MN
![Page 11: Test Report No. ENV-PR085361-00 Rev. 1Test Report No. ENV-PR085361-00 Rev. 1 Page 1 of 40 This report and the information contained herein represents the results of testing of only](https://reader033.vdocuments.site/reader033/viewer/2022052022/603809ec96d73138631fef18/html5/thumbnails/11.jpg)
Test Report No. ENV-PR085361-00 Rev. 1
11
TEST DATA
Humidity:
![Page 12: Test Report No. ENV-PR085361-00 Rev. 1Test Report No. ENV-PR085361-00 Rev. 1 Page 1 of 40 This report and the information contained herein represents the results of testing of only](https://reader033.vdocuments.site/reader033/viewer/2022052022/603809ec96d73138631fef18/html5/thumbnails/12.jpg)
Test Report No. ENV-PR085361-00 Rev. 1
12
![Page 13: Test Report No. ENV-PR085361-00 Rev. 1Test Report No. ENV-PR085361-00 Rev. 1 Page 1 of 40 This report and the information contained herein represents the results of testing of only](https://reader033.vdocuments.site/reader033/viewer/2022052022/603809ec96d73138631fef18/html5/thumbnails/13.jpg)
Test Report No. ENV-PR085361-00 Rev. 1
13
![Page 14: Test Report No. ENV-PR085361-00 Rev. 1Test Report No. ENV-PR085361-00 Rev. 1 Page 1 of 40 This report and the information contained herein represents the results of testing of only](https://reader033.vdocuments.site/reader033/viewer/2022052022/603809ec96d73138631fef18/html5/thumbnails/14.jpg)
Test Report No. ENV-PR085361-00 Rev. 1
14
![Page 15: Test Report No. ENV-PR085361-00 Rev. 1Test Report No. ENV-PR085361-00 Rev. 1 Page 1 of 40 This report and the information contained herein represents the results of testing of only](https://reader033.vdocuments.site/reader033/viewer/2022052022/603809ec96d73138631fef18/html5/thumbnails/15.jpg)
Test Report No. ENV-PR085361-00 Rev. 1
15
High Temperature:
![Page 16: Test Report No. ENV-PR085361-00 Rev. 1Test Report No. ENV-PR085361-00 Rev. 1 Page 1 of 40 This report and the information contained herein represents the results of testing of only](https://reader033.vdocuments.site/reader033/viewer/2022052022/603809ec96d73138631fef18/html5/thumbnails/16.jpg)
Test Report No. ENV-PR085361-00 Rev. 1
16
Low Temperature:
![Page 17: Test Report No. ENV-PR085361-00 Rev. 1Test Report No. ENV-PR085361-00 Rev. 1 Page 1 of 40 This report and the information contained herein represents the results of testing of only](https://reader033.vdocuments.site/reader033/viewer/2022052022/603809ec96d73138631fef18/html5/thumbnails/17.jpg)
Test Report No. ENV-PR085361-00 Rev. 1
17
![Page 18: Test Report No. ENV-PR085361-00 Rev. 1Test Report No. ENV-PR085361-00 Rev. 1 Page 1 of 40 This report and the information contained herein represents the results of testing of only](https://reader033.vdocuments.site/reader033/viewer/2022052022/603809ec96d73138631fef18/html5/thumbnails/18.jpg)
Test Report No. ENV-PR085361-00 Rev. 1
18
Power Variation:
![Page 19: Test Report No. ENV-PR085361-00 Rev. 1Test Report No. ENV-PR085361-00 Rev. 1 Page 1 of 40 This report and the information contained herein represents the results of testing of only](https://reader033.vdocuments.site/reader033/viewer/2022052022/603809ec96d73138631fef18/html5/thumbnails/19.jpg)
Test Report No. ENV-PR085361-00 Rev. 1
19
Vibration:
![Page 20: Test Report No. ENV-PR085361-00 Rev. 1Test Report No. ENV-PR085361-00 Rev. 1 Page 1 of 40 This report and the information contained herein represents the results of testing of only](https://reader033.vdocuments.site/reader033/viewer/2022052022/603809ec96d73138631fef18/html5/thumbnails/20.jpg)
Test Report No. ENV-PR085361-00 Rev. 1
20
![Page 21: Test Report No. ENV-PR085361-00 Rev. 1Test Report No. ENV-PR085361-00 Rev. 1 Page 1 of 40 This report and the information contained herein represents the results of testing of only](https://reader033.vdocuments.site/reader033/viewer/2022052022/603809ec96d73138631fef18/html5/thumbnails/21.jpg)
Test Report No. ENV-PR085361-00 Rev. 1
21
TEST SETUP
Humidity:
![Page 22: Test Report No. ENV-PR085361-00 Rev. 1Test Report No. ENV-PR085361-00 Rev. 1 Page 1 of 40 This report and the information contained herein represents the results of testing of only](https://reader033.vdocuments.site/reader033/viewer/2022052022/603809ec96d73138631fef18/html5/thumbnails/22.jpg)
Test Report No. ENV-PR085361-00 Rev. 1
22
![Page 23: Test Report No. ENV-PR085361-00 Rev. 1Test Report No. ENV-PR085361-00 Rev. 1 Page 1 of 40 This report and the information contained herein represents the results of testing of only](https://reader033.vdocuments.site/reader033/viewer/2022052022/603809ec96d73138631fef18/html5/thumbnails/23.jpg)
Test Report No. ENV-PR085361-00 Rev. 1
23
High Temperature:
![Page 24: Test Report No. ENV-PR085361-00 Rev. 1Test Report No. ENV-PR085361-00 Rev. 1 Page 1 of 40 This report and the information contained herein represents the results of testing of only](https://reader033.vdocuments.site/reader033/viewer/2022052022/603809ec96d73138631fef18/html5/thumbnails/24.jpg)
Test Report No. ENV-PR085361-00 Rev. 1
24
![Page 25: Test Report No. ENV-PR085361-00 Rev. 1Test Report No. ENV-PR085361-00 Rev. 1 Page 1 of 40 This report and the information contained herein represents the results of testing of only](https://reader033.vdocuments.site/reader033/viewer/2022052022/603809ec96d73138631fef18/html5/thumbnails/25.jpg)
Test Report No. ENV-PR085361-00 Rev. 1
25
Low Temperature:
![Page 26: Test Report No. ENV-PR085361-00 Rev. 1Test Report No. ENV-PR085361-00 Rev. 1 Page 1 of 40 This report and the information contained herein represents the results of testing of only](https://reader033.vdocuments.site/reader033/viewer/2022052022/603809ec96d73138631fef18/html5/thumbnails/26.jpg)
Test Report No. ENV-PR085361-00 Rev. 1
26
![Page 27: Test Report No. ENV-PR085361-00 Rev. 1Test Report No. ENV-PR085361-00 Rev. 1 Page 1 of 40 This report and the information contained herein represents the results of testing of only](https://reader033.vdocuments.site/reader033/viewer/2022052022/603809ec96d73138631fef18/html5/thumbnails/27.jpg)
Test Report No. ENV-PR085361-00 Rev. 1
27
Bench Handling:
![Page 28: Test Report No. ENV-PR085361-00 Rev. 1Test Report No. ENV-PR085361-00 Rev. 1 Page 1 of 40 This report and the information contained herein represents the results of testing of only](https://reader033.vdocuments.site/reader033/viewer/2022052022/603809ec96d73138631fef18/html5/thumbnails/28.jpg)
Test Report No. ENV-PR085361-00 Rev. 1
28
![Page 29: Test Report No. ENV-PR085361-00 Rev. 1Test Report No. ENV-PR085361-00 Rev. 1 Page 1 of 40 This report and the information contained herein represents the results of testing of only](https://reader033.vdocuments.site/reader033/viewer/2022052022/603809ec96d73138631fef18/html5/thumbnails/29.jpg)
Test Report No. ENV-PR085361-00 Rev. 1
29
Vibration:
![Page 30: Test Report No. ENV-PR085361-00 Rev. 1Test Report No. ENV-PR085361-00 Rev. 1 Page 1 of 40 This report and the information contained herein represents the results of testing of only](https://reader033.vdocuments.site/reader033/viewer/2022052022/603809ec96d73138631fef18/html5/thumbnails/30.jpg)
Test Report No. ENV-PR085361-00 Rev. 1
30
![Page 31: Test Report No. ENV-PR085361-00 Rev. 1Test Report No. ENV-PR085361-00 Rev. 1 Page 1 of 40 This report and the information contained herein represents the results of testing of only](https://reader033.vdocuments.site/reader033/viewer/2022052022/603809ec96d73138631fef18/html5/thumbnails/31.jpg)
Test Report No. ENV-PR085361-00 Rev. 1
31
![Page 32: Test Report No. ENV-PR085361-00 Rev. 1Test Report No. ENV-PR085361-00 Rev. 1 Page 1 of 40 This report and the information contained herein represents the results of testing of only](https://reader033.vdocuments.site/reader033/viewer/2022052022/603809ec96d73138631fef18/html5/thumbnails/32.jpg)
Test Report No. ENV-PR085361-00 Rev. 1
32
![Page 33: Test Report No. ENV-PR085361-00 Rev. 1Test Report No. ENV-PR085361-00 Rev. 1 Page 1 of 40 This report and the information contained herein represents the results of testing of only](https://reader033.vdocuments.site/reader033/viewer/2022052022/603809ec96d73138631fef18/html5/thumbnails/33.jpg)
Test Report No. ENV-PR085361-00 Rev. 1
33
![Page 34: Test Report No. ENV-PR085361-00 Rev. 1Test Report No. ENV-PR085361-00 Rev. 1 Page 1 of 40 This report and the information contained herein represents the results of testing of only](https://reader033.vdocuments.site/reader033/viewer/2022052022/603809ec96d73138631fef18/html5/thumbnails/34.jpg)
Test Report No. ENV-PR085361-00 Rev. 1
34
TEST EQUIPMENT LOGS
![Page 35: Test Report No. ENV-PR085361-00 Rev. 1Test Report No. ENV-PR085361-00 Rev. 1 Page 1 of 40 This report and the information contained herein represents the results of testing of only](https://reader033.vdocuments.site/reader033/viewer/2022052022/603809ec96d73138631fef18/html5/thumbnails/35.jpg)
Test Report No. ENV-PR085361-00 Rev. 1
35
![Page 36: Test Report No. ENV-PR085361-00 Rev. 1Test Report No. ENV-PR085361-00 Rev. 1 Page 1 of 40 This report and the information contained herein represents the results of testing of only](https://reader033.vdocuments.site/reader033/viewer/2022052022/603809ec96d73138631fef18/html5/thumbnails/36.jpg)
Test Report No. ENV-PR085361-00 Rev. 1
36
![Page 37: Test Report No. ENV-PR085361-00 Rev. 1Test Report No. ENV-PR085361-00 Rev. 1 Page 1 of 40 This report and the information contained herein represents the results of testing of only](https://reader033.vdocuments.site/reader033/viewer/2022052022/603809ec96d73138631fef18/html5/thumbnails/37.jpg)
Test Report No. ENV-PR085361-00 Rev. 1
37
![Page 38: Test Report No. ENV-PR085361-00 Rev. 1Test Report No. ENV-PR085361-00 Rev. 1 Page 1 of 40 This report and the information contained herein represents the results of testing of only](https://reader033.vdocuments.site/reader033/viewer/2022052022/603809ec96d73138631fef18/html5/thumbnails/38.jpg)
Test Report No. ENV-PR085361-00 Rev. 1
38
![Page 39: Test Report No. ENV-PR085361-00 Rev. 1Test Report No. ENV-PR085361-00 Rev. 1 Page 1 of 40 This report and the information contained herein represents the results of testing of only](https://reader033.vdocuments.site/reader033/viewer/2022052022/603809ec96d73138631fef18/html5/thumbnails/39.jpg)
Test Report No. ENV-PR085361-00 Rev. 1
39
Vibration:
ID Number
Manufacturer Model #
Serial # Description Cal Date Cal Due
1750 Team 80/10.5 544 Shaker System HYD06
For reference only
1751 Team 483 48-16
494 Shaker System HYD05
For reference only
1704 Vibration Research
VR9500 9521DE37 Vibration Controller 6/11/2018 6/11/2019
1697 PCB 353B34 LW204221 Accelerometer 10/04/17 10/04/18
1698 PCB 353B34 LW204222 Accelerometer 11-13-17 11-13-18
1766 Fluke 971 3623064 Temperature/Humidity
meter 4/23/2018 4/23/2019
![Page 40: Test Report No. ENV-PR085361-00 Rev. 1Test Report No. ENV-PR085361-00 Rev. 1 Page 1 of 40 This report and the information contained herein represents the results of testing of only](https://reader033.vdocuments.site/reader033/viewer/2022052022/603809ec96d73138631fef18/html5/thumbnails/40.jpg)
Test Report No. ENV-PR085361-00 Rev. 1
40
END OF REPORT