test report motor_4578450aaeng
TRANSCRIPT
ABB AUTOMATION PRODUCTS GMBH
812/3800278942/APR/VLM 242004Komatsu Mining Repeat
AMA 500L4A BAXYH
4578450
CustomerProject
MachineWork nrSerial nr
Test report for asynchronous machines
3689HE200
Date
Order ref.
19.10.2004
Approved on the behalf of manufacturer
Tero Kantell
ABB Oy, Electrical MachinesVisiting AddressStrömbergintie 1HELSINKI
Postal AddressP.O.Box 186FIN-00381 HELSINKIFinland
Telefax(Group)+358 10 22 22330Telefax(Test Floor)+358 10 22 23692
TEST REPORT
4578450 A
Machine Page
Revision
CustomerABB AUTOMATION PRODUCTS GMBH
Project
Work nr
Approved
AMA 500L4A BAXYH
Komatsu Mining Repeat
812/3800278942/APR/VLM 242004Serial nrOrder ref.
3689HE200Report rev
A
2
Tero Kantell
Ambient temp. maxp.f.I [A]U [V]f [Hz] DutyConnection Direction n [rpm]
Ratings
F IM 1001
55.0 °CB
IEC
IP 55Temperature classInsulation class
StandardsMachine
P [kW] / [hp]
Specification
Protection classMounting
TL92701040a
60.0 Y 7200 0.88 <== 1767 S11401450 / 1943Amb. -30 ... +55 °C
Table of contents / Test program1) Visual inspection2) Insulation resistances before tests3) Resistance measurement of windings and elements4) Direction of rotation, checking of phase sequence5) Short-circuit point6) No-load point7) Vibration measurement8) High voltage test9) Insulation resistances after tests
TEST REPORT
4578450 A
Machine Page
Revision
CustomerABB AUTOMATION PRODUCTS GMBH
Project
Work nr
Approved
AMA 500L4A BAXYH
Komatsu Mining Repeat
812/3800278942/APR/VLM 242004Serial nrOrder ref.
3689HE200Report rev
A
3
Tero Kantell
Visual inspection
Version Notes
1)
OKA
Insulation resistances before tests
Winding R [Mohm] U [V]20.6 °Cυ =
2)
29800 1000Stator
Space heaterR [Mohm]
191000U [V]
500Temperature detectors R [Mohm] U [V]
StatorBearing
324000510000
500500
Auxiliaries
Other
Rvw [ohm]
Resistance measurement of windings and elements
Ruv [ohm] Ruw [ohm]υ =Winding
3)
20 °C
0.34720 0.34722 0.34711Stator
Terminals R [ohm] Position Detector20.6 °Cυ =
1 - 2 Space heater RER-Z 21149.23 - 4,5 Stator, U-phase PYR PT100LG4/4EX108.16 - 7,8 Stator, V-phase PYR PT100LG4/4EX108.19 - 10,11 Stator, W-phase PYR PT100LG4/4EX108.012 - 13,14 Stator, U-phase PYR PT100LG4/4EX107.915 - 16,17 Stator, V-phase PYR PT100LG4/4EX108.018 - 19,20 Stator, W-phase PYR PT100LG4/4EX108.121 - 22,23 D.E - bearing PYR PT100BB4/4Z108.124 - 25,26 N.D.E - bearing PYR PT100BB4/4Z108.1
U-V-W | L3-L2-L1 | <<< (CCW)Result
4) Direction of rotation, checking of phase sequence
Connection f [Hz] U1 [V] P1 [kW] p.f. Ik [A] Un [V]
Short-circuit point
I1 [A] υ[°C]
5)
Y 60.0 2099.5 21.262.10 0.121 7200482.5140.7
No-load point
Connection f [Hz] U1 [V] DirectionP1 [kW] p.f.I1 [A] υ[°C]
6)
Y 60.0 7202.5 30.432.31 30.70 0.076 CCW
TEST REPORT
4578450 A
Machine Page
Revision
CustomerABB AUTOMATION PRODUCTS GMBH
Project
Work nr
Approved
AMA 500L4A BAXYH
Komatsu Mining Repeat
812/3800278942/APR/VLM 242004Serial nrOrder ref.
3689HE200Report rev
A
4
Tero Kantell
Vibration measurement7)
Mounting RigidBearing position U [V] I [A] f[Hz] Horizontal Vertical Axial UnitD-END 7203 32 60.0 0.23 0.33 0.56 mm/sND-END 7203 32 60.0 0.31 0.19 0.53 mm/s
TypeIdMeasuring equipment
Name Next Cal DueCal Date715761 Vibration analyzer CSI 1910, vibration analyzer (1) 8.12.20048.6.2004
High voltage test
U [V] f [Hz]t [s]Winding
8)
Stator 17400 5060
1500 5060
1500 5060500 5060
Space heater
StatorBearing
Temperature detectors
Auxiliaries
Insulation resistances after tests
R [Mohm] t [s]υ = 30.1°C
U [V]Winding
9)
15400 60 1000StatorAuxiliariesSpace heater
R [Mohm]141000
U [V]500
Temperature detectors R [Mohm] U [V]StatorBearing 474000
306000 500500
End of report
21.10.2004Number of pages Printed:Tero Kantell
Test bay SY4 (Synchronous, test bench no. 4)Author Nuuttila, Ollanketo
4
2.1/7
TEST REPORT