  • TEST REPORT

    Report No.: SF201400183-1 Page 1 of 54

    Client: Ningbo Lengon Electric Co., Ltd.

    Address: No.1 Shengli Road, Guanhaiwei Town, Cixi City, Ningbo, China

    Sample Description: Pop up socket

    Model: D08-ALU02, D08-ALU03, D08-ALU04, D08-AL02, D08-AL03, D08-AL04

    Test Location: GUANGZHOU GRG METROLOGY & TEST CO.,LTD. GRGTS SAFETY LAB

    Test Specification: AS/NZS 3105:2012: Approval and test specification - Electrical portable outlet devices AS/NZS 3100:2009+Amdt 1:2010+Amdt 2:2012: Approval and test specification - General requirements for electrical equipment AS/NZS 3112:2011+Amdt 1:2012+Amdt 2:2013: Approval and test specification -Plugs and socket-outlets

    Test Date: 2014-07-01 ~ 2014-08-26

    Test Result: Pass

    Tested By: Reviewed By: Approved By:

    Tony Qin Zeming Zhang Connie Yang

    Date:

    Date:

    Date:

    Other Aspects: /

    This report use together with SF201400183-2.

    Abbreviations: ok / P = passed; fail / F = failed; N/A = not applicable The test result in this test report refers exclusively to the presented test sample. This report shall not be reproduced except in full, without the written approval of GRGT.

    GUANGZHOU GRG METROLOGY & TEST CO.,LTD. Address: 163, Pingyun Road, West of Huangpu Avenue, Guangzhou, Guangdong, P.R. China

    Tel:+86-20-38699960 Fax:+86-20-38695185 Email: [email protected] http://www.grgtest.com Ver.:1.0 / 09.Sep.2008

  • Report No. SF201400183-1 Page 2 of 54

    Test item description ..................................:

    Manufacturer .................................................: Ningbo Lengon Electric Co., Ltd.

    Address ..........................................................: No.1 Shengli Road, Guanhaiwei Town, Cixi City, Ningbo, China

    Factory ...........................................................: Ningbo Lengon Electric Co., Ltd.

    Address ..........................................................: No.1 Shengli Road, Guanhaiwei Town, Cixi City, Ningbo, China

    Model/Type reference ....................................: D08-ALU02, D08-ALU03, D08-ALU04, D08-AL02, D08-AL03, D08-AL04

    Trade Mark ....................................................: Lengon

    Ratings ...........................................................: 220-240V~, 10A, 2400W, 50Hz, USB Output: 5VDC, 1.0A

    Test item particulars ....................................:

    Standard Sheet ..............................................: AS/NZS 3112, Figure 3.2 Rated current (A) / Rated voltage (V) ............: 10A / 220-240V Degree of protection against access to hazardous parts and against harmful ingress of solid foreign objects ...................................:

    IP2X

    Degree of protection against harmful ingress of water ..........................................................:

    IPX0

    Provision for earthing .....................................: with earthing contact Method of connecting the cable ....................: non-rewirable Type of cable .................................................: DL3, Ordinary type Nominal cross-sectional areas (mm2) ............: 3x1.5 Type of terminals ...........................................: N/A Type of connections ......................................: soldered Existence of shutters .....................................: No Existence of switch ........................................: No Existence of lampholder ................................: No Existence of overcurrent protection device ...: Yes (circuit breaker) Existence of electronic circuits ......................: Yes Existence of interconnection circuits .............: No Existence of enclosures .................................: Yes

    General remarks:

    The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory. "(see Enclosure #)" refers to additional information appended to the report. "(see appended table)" refers to a table appended to the report. Throughout this report a point is used as the decimal separator.

  • Report No. SF201400183-1 Page 3 of 54

    General product information: 1. Main model: D08-ALU04; adding model: D08-ALU02, D08-ALU03, D08-AL02, D08-AL03, D08-AL04. 2. All tests were conducted on the model D08-ALU04 3. Model list and difference description among these models:

    Model Socket-outlet Circuit breaker USB charger module

    D08-ALU02 2 0 1

    D08-ALU03 3 1 1

    D08-ALU04 4 1 1

    D08-AL02 2 0 0

    D08-AL03 3 1 0

    D08-AL04 4 1 0

    Copy of marking plate:

    Remark: Marking plate of other models are the same except model name.

  • Report No. SF201400183-1 Page 4 of 54 AS/NZS 3105

    Clause Requirement + Test Result - Remark Verdict

    3 COMPLIANCE WITH STANDARDS P

    3.1 General requirements of AS/NZS 3100 P

    3.2 Specific requirements of this Standard P

    3.3 Requirements of other Standards P

    4 DESIGN AND CONSTRUCTION P

    4.1 Current rating of any outlet facility not greater than that of the plug or appliance inlet; nor greater than the current-carrying capacity of power supply cord or flexible cable

    Rated as 10Amp. P

    4.2 Enclosing case is of robust construction and adequate mechanical strength; complying with 8.4

    No damage apparent after the test.

    P

    4.3 Insulating material P

    a) Insulating material having properties not inferior to those for class 60 moulding as specified in AS/NZS 3121 and that comply with clause 8.9; or

    P

    Resistance to heat test at per AS/NZS 3121; 6 h at 70C

    P

    Water absorption test as per AS/NZS 3121; 48 h P

    Resistance to white spirits as per AS/NZS 3121; 2 min

    P

    b) Ceramic material of a type that; after immersion in water for 48 h and with surface drops removed, has not increased in mass by more than 2%

    N/A

    Compliance test; increase in mass N/A

    4.4 Any power supply cord or outgoing flexible cords P

    a) Complies with AS/NZS 3191, AS/NZS 60227.5 or AS/NZS 60245.4

    AS/NZS 3191 P

    b) 3-core ordinary duty or heavy duty type 3-core ordinary duty. P

    c) Has conductors with cross-sectional area of not less than 1 mm

    1.5 mm2 P

    d) For power supply cord, complies with clause 6.3 P

    4.5 Outlet facilities P

    4.5.1 Socket-outlets, cord extension sockets or connectors P

    4.5.1.1 An EPOD may consist of outlet facilities described in Clauses 4.5.1.2, 4.5.1.3, 4.5.1.4 or a combination of these outlet facilities, subject to meeting requirements of all clauses of this Standard.

    P

    4.5.1.2 EPOD provided with one or more socket-outlets: 4, 3 or 2 socket-outlets. P

    a) Complying with relevant requirements of AS/NZS 3112

    See AS/NZS 3112 part. P

    Except that on the plane of the socket-outlet faceplate; P

    i) Minimum distance from edge of live-pin aperture to edge of faceplate is 13.7 mm; and

    Min. 23.8 mm. P

  • Report No. SF201400183-1 Page 5 of 54 AS/NZS 3105

    Clause Requirement + Test Result - Remark Verdict

    ii) Maximum distance by which faceplate, within distance specified, is below the plane is 3 mm

    0 mm P

    b) Each intended to accommodate a three-pin flat-pin plug conforming to AS/NZS 3112

    P

    No part of the device, including any switch projects more than 8.6 mm from the surface of the socket- outlet face within shaded area of Figure 1

    No projections. P

    Exemption for socket-outlets with special design features N/A

    No projections in area defined by R21.6 in Figure 1 No projections. P

    Devices incorporating more than one socket-outlet; centre-to-centre distance between adjacent socket-outlets greater than 44 mm

    P

    Measured.............................................................: Min. 54.0 mm P

    4.5.1.3 EPOD may be provided with one or more cord extension sockets each rated up to 10 A complying with the relevant requirements of AS/NZS 3120.

    N/A

    For EPODs incorporating cord extension sockets, individual cord anchorages shall be provided for each outgoing flexible cord at the body of the EPOD, however where just two cord extension sockets terminate to an EPOD body the junction described in Clause 2.5 may alternatively be used.

    N/A

    4.5.1.4 EPOD may be provided with one or more connectors each rated up to 10 A complying with the relevant requirements of AS/NZS 60320.1 for connectors for Class I equipment.

    N/A

    For EPODs incorporating connectors, individual cord anchorages shall be provided for each outgoing flexible cord at the body of the EPOD, however where just two connectors terminate to the body of the EPOD the junction described in Clause 2.5 may alternatively be used.

    N/A

    4.5.2 One or more lampholders incorporated; following conditions met: N/A

    a) Maximum connected lamp load not exceeding 10% of device rating

    N/A

    b) Lamp protected by substantial guard or enclosure that cannot be removed without the aid of a tool