TEST REPORT
LED BASED SPV HOME LIGHTING SYSTEM
Sl.
No.
Test description Observations Requirement as per
TEDA specifications
Remarks
1.0 PV MODULE 1.1 Type of module Mono / Poly crystalline
Silicon
1.2 Manufacturer
1.3 Sl. Nos.
1.4
Module configuration 50 Wp
1.5 Peak Power at STC Should be 50W or more
1.6 Voc Min 21V
2.0 LED LUMINAIRE 2.1 Make & Sl.Nos of Luminaire 7W-
5W-
3W-
2.2 Make of LED CREE/NICHIA/OSRAM/SEOUL/
PHILIPS LUMILEDS/LEDNIUM
or equivalent
2.3 Power consumption of
Luminaries
< = 7 W
<= 5W
<= 3 W
2.4 Driver Efficiency
( Input 12V DC)
>= 90%
2.5 Lux level requirements on the
floor when mounted at 2.5m
height assuming zero
reflection factor
a. 7W Luminary in room
size of 3.75x2.44x3m
i. Average lux
ii. Uniformity
b. 5W Luminary in room
size of 2.73x2.44x3m
i. Average lux
ii. Uniformity
c. 3W Luminary in room
size of 1.3x1.3x3m
i. Average lux
ii. Uniformity
>=7
>=0.7
>=5.5
>=0.8
>=3.5
>=0.8
2
Sl.
No
Test description Observations Requirement as
per TEDA
specifications
Remarks
3.0 BATTERY
3.1 Make & Sl.No M/s.
3.2 Type of battery LMLA / VRLA
3.3 Rated Capacity at C/10
discharge rate (12V)
Ah
40Ah
3.4 % of rated capacity between
battery high and low
Conforms
Atleast 75 %
3.5 Protections
Low voltage cut off
Load reconnect
Over charge cut off
Module reconnect
4.0 CHARGE CONTROL UNIT 4.1.1 Make
4.1.2 Sl.No
4.1.3 PV Array charging efficiency >=90%
4.1.4 AC mains charging efficiency >=85%
4.1.5 Sl
No
Parameters as per
IEC-62093
1 Visual inspection (Cl.
11.1)
2 Functioning test (Cl.
11.2)
a. Maximum Voltage drop
across the charge
controller
b. Idle current consumption
of the charge controller
circuit (Quiescent
current)
c. Charge controller output
suitable for nominal
battery bank
3 Insulation resistance test
(Cl. 11.4)
4 Protection against
mechanical impact
(Cl. 11.6)
5 Bulk Voltage ____
3
6 Float Voltage ____
7
a.
b.
c.
d.
e.
Protection
No load
Short circuit
Reverse polarity
Reverse flow
Battery temperature
Compensation
5.0 ENVIRONMENTAL TEST FOR CCU & LED LUMINAIRE
a.
b.
c.
Environmental Testing
Dry Heat test as per
IEC 60068-2-2
(+55oC+/- 2
oC for 16 Hrs)
Change of Temperature Test
IEC 60068-2-14
(+5oC &+55
oC+/- 3
oC Duration
at each temperature:1 Hr , Rate
of change of
temperature:10C/Min, No of
cycles:5)
Damp Heat test
IEC 60068-2-30
(Temp25oC to 55
oC+/-2
oC,
variant1,12+12 Hrs cycle, No of
cycle:2, Humidity:93 +/-3% RH)
6.0 IP TEST FOR CCU & LED LUMINAIRE
a.
b.
IP 21 CCU
IP 41 for LED Luminary
Conclusions: It is endorsed that LED based SPV home lighting system
submitted by M/s. …………………… qualifies TEDA Specification and
M/s. …………………………is the original manufacturer
of……………………..
Note:
Copy of Test certificates/ Reports for the following components towards
compliance of standards as per Clause-18 of the tender document shall also be
submitted along with the above report:
1. PV Module
2. Battery
3. LED / Luminaire
4. Cables & Switches